1 ibutton Eternity Series Locks Programming Guide ssentryloc trylocks.co ibutton Eternity E4 Keypad/Combination Entry Door Lock Heavy-Duty Commercial Grade ibutton Eternity E5 Keypad/Combination Entry Door Lock with Lighted Keypad cks.co Keyless Entry Locks For current prices, please visit our website. Wheaton, IL Page 1 of 58 FAX: (630)

2 ibutton Eternity Series Door Lock Programming Guide Table of Contents ssentryloc Section: Table of Contents Table of Contents...2 Programming Guide Non-Software Version...4 General Information...4 Unlocking / Locking Indicators...5 Resetting, Reinitializing or Erasing Lock Memory...6 Programming Mode...8 Different Types of Codes...8 Index Number...10 Different Types of Modes...10 Passage Mode: Storehouse Mode: Lockout Mode: Time and Date Format...11 trylocks.co Get Started Programming...12 Basic Functions...12 Advanced Functions...13 User Schedule Programming Examples...16 Lock Schedule Programming Examples...19 Trouble Shooting Guide...21 Programming Guide Software Version...22 General Overview...22 Foreword Important Information Software Specifications cks.co Eternity 3.7 Software Guide...26 Wheaton, IL Page 2 of 58 FAX: (630)

3 Section: Table of Contents Software Setup Access Control Management...28 Advanced Access Control Management...38 Warranty Information...58 Contact Information...58 ssentryloc trylocks.co cks.co Wheaton, IL Page 3 of 58 FAX: (630)

4 E5 v4.1 Non-Software Lock: Programming Guide Non-Software Version General Information ssentryloc Section: Programming Guide Non-Software The non-software version of the E5 lock is programmed completely using the keypad on the lock itself. In other words, a personal computer cannot be used for programming. If you have purchased a non-software version of the E5 and wish to upgrade to the software version E5, your E5 (except E5RFKSC) can be retrofitted with a replacement printed circuit board converting it to software operation. Although field retrofit is possible, it is not normally recommended. Contact your dealer or distributor for details. E4 / E5 v8.6 Software Locks: The software version of the E4 or E5 can be programmed either manually via the keypad on the E4 / E5 or with a personal computer, DS1977 program ibutton key, software and a Blue-dot USB reader. Most manual program modes and methods used by the non-software E5 are available when manually programming the software version E4 or E5. However, an important consideration is that once you elect to program your E4 / E5 software lock manually instead of using a personal computer you must continue to use that same method. You cannot mix the two programming methods (manually and using software) for a given lock. Should you program your software version E4 / E5 lock manually and later decide to use a personal computer to program the E4 / E5, you will need to completely reinitialize the lock and reprogram the lock from the manufacturer s default state using the personal computer hardware, software and processes. trylocks.co Exit Setting Mode: To exit the setting mode, enter * or wait 10 seconds. Low Battery Warning: After entering a valid ibutton key or keypad user code, the LED in the center of the ibutton reader will flash 5 times. This indicates that the total battery voltage is less than 4.8 volts and the AA batteries need to be replaced. Non-Software E5 Lock: The non-software version of the E5 lock will flash the LED red 5 times very rapidly when the batteries are in need of replacement. cks.co Software Version E5 lock: The software E4/E5 version will flash the LED red 5 times slowly when the batteries are in need of replacement. Wheaton, IL Page 4 of 58 FAX: (630)

5 Non-Software E5 Lock: Unlocking / Locking Indicators Section: Programming Guide Non-Software When in the Storehouse mode, the non-software version of the E5 will light the LED in the center of the ibutton reader green when unlocked with the keypad or ibutton. It will stay green until the lock re-locks, when the LED will flash red twice to indicate the lock has relocked itself. In general, the LED will also flash once every time a key is pressed on the keypad. ssentryloc Software Version E4 / E5 Lock: The software E4 / E5 version will light briefly when unlocking. When relocking, the LED does not light. In general, the LED will also flash once every time a key is pressed on the keypad. LED Blink Mode: For both the non-software version E5 and the software version E4 / E5, the LED in the center of the ibutton reader can be set to flash once every 5 seconds. If the lock is locked, it will flash red, if unlocked it will flash green. This is a useful feature but can also reduce battery life somewhat. (This function is programmable using 'function code #18') E4 ibutton Reader Location: On E4 model locks, the ibutton reader is located just below the keypad on the front of the lock. trylocks.co E5 ibutton Reader Location: On E5 model locks, the ibutton reader is located just above the keypad on the front of the lock. cks.co Wheaton, IL Page 5 of 58 FAX: (630)

6 ibutton Key Fobs: ssentryloc Section: Programming Guide Non-Software ibuttons and ibutton readers are not magnetic but rather fully electronic. ibuttons are very resistant to water and shock. They are also available in various types and when desired are installed in various colored plastic keyring tags. The color has no particular meaning. Only DS1990 ibuttons and user keypad codes are used as 'User keys' when programming E4 / E5 locks via the keypad. (DS1977 ibuttons are used to program locks only when using PC computer software to program locks.) It is not required to apply great physical pressure with an ibutton on the reader, only that the center portion of an ibutton touches the center of the reader at the same time as the outer portion of the ibutton rests on the outer ring of the reader. This is most easily done by holding the ibutton against the reader slightly off center and at a bit of an angle. Non-Software E5 Lock: Resetting, Reinitializing or Erasing Lock Memory trylocks.co The reset button is located just below the battery holder, next to the cable connector. Press and hold the reset button below the battery holder. The LED in the center of the ibutton reader will light red. After 5 seconds, the lock will beep once. Continue to hold the button down until the lock beeps 3 times rapidly while the LED in the center of the ibutton reader flashes green. Release the reset button immediately. Software Version E5 lock: The reset button is located just below the battery holder, next to the cable connector. Press and hold the reset button below the battery holder. The LED in the center of the ibutton reader will light green. After 5 seconds the lock will beep once. Continue to hold the button down until the LED flashes red slowly. Release the reset button immediately and press the # key while the LED is still flashing. The lock will beep 3 times, indicating the reset and clear has been successful. cks.co Wheaton, IL Page 6 of 58 FAX: (630)

7 ssentryloc E4 Lock Section: Programming Guide Non-Software The reset button is located just below the battery holder in a recessed hole. Use a narrow object such as a straightened paper clip to press the button in. Press and hold the reset button below the battery holder. The LED in the center of the ibutton reader will light green. After 5 seconds the lock will beep once. Continue to hold the button down until the LED flashes red slowly. Release the reset button immediately and press the # key while the LED is still flashing. The lock will beep 3 times, indicating the reset and clear has been successful. Lock Manufacturer Default Settings, E4 / E5: These settings apply for a new lock or one that has had a full reset as per the reset procedures above: Default master code: Auto unlock/lock: Disabled Default lock mode: Storehouse mode Default Daylight savings mode: Disabled Construction code: 0#, only applies until first regular user code is programmed. trylocks.co cks.co Wheaton, IL Page 7 of 58 FAX: (630)

8 Non-Software E5: Programming Mode Section: Programming Guide Non-Software When the # key is the first key pressed, the E5 enters programming mode, a state in which the E5 is expecting the user to enter a set of programming commands. The LED will flash rapidly to show that it has entered programming mode. If a valid set of programming keypad entries are not then entered within 10 seconds, the E5 will beep and drop out of programming mode and return to waiting for a valid user code. ssentryloc Software Version E5: When the # key is first pressed, the E5 enters programming mode, a state in which the E5 is expecting the user to enter a programming command. The LED will flash once and the keypad will briefly light, but there is no other indication that programming mode has been entered. If a valid set of programming keypad entries are not then entered within 10 seconds, the E5 will automatically drop out of programming mode and return to waiting for a valid user code. Master Code: Different Types of Codes The master code is a user changeable keypad code that allows the lock to be put in a programming mode. It cannot be used to open or close the lock. The manufacture s default master code is , which should be changed to a new customer chosen code for security purposes as soon as possible after installing the lock. The master code number chosen cannot be duplicated elsewhere as a regular user key code. User Code: trylocks.co User codes are keypad codes that are assigned by the customer to individual users to lock and unlock the E5 lock. The # key is always used after the regular users enter their code number to let the lock know the entire number has been entered, since the number of digits in a user's code is not fixed. This doesn't apply to ibutton use. Non-Software E5 Lock: The user code can be any number up to 11 digits long providing it is not the same as the master code number that is assigned to the lock. Users are automatically assigned an index number in the order that they are added, beginning at 001 and incrementing by one at every new user (that is 001,002,003,004, etc.). You should keep track of what this index number is for each user because this is required to later delete a user should you wish to do so. cks.co Software Version E5 lock: The user code can be any number up to 12 digits long as long as it is not the same as the master code number that is currently assigned to the lock. Users are automatically assigned an index Wheaton, IL Page 8 of 58 FAX: (630)

9 Section: Programming Guide Non-Software number in the order that they are added, beginning at 001 and incrementing by one at every new user (that is, 001,002,003,004, etc.). You should keep track of what this index number is for each user, as this is useful but not absolutely required to later delete a user should you wish to do so. (Software version locks have an additional feature not found in the non-software version locks it allows users to be deleted if you know what their user code key is or what their index number is.) Construction / Installer Code: Non-Software E5 Lock: ssentryloc The Construction / Installer code is a manufacturer s default code for use by a lock installer or during the construction phase of a building. The Construction / Installer code is 0 (zero), then the # sign. This allows the installer to easily test locking and unlocking the E5 lock or to allow easy access during construction. This code is automatically deleted when the first regular new user code is programmed into the E5 lock. Software Version E5: The Construction / Installer code is a manufacturer s default code for use by a lock installer or during the construction phase of a building. The Construction / Installer code is 0 (zero), then the # sign. This allows the installer to easily test locking and unlocking the E5 lock or to allow easy access during construction. This code is automatically deleted when the first regular new user code is programmed into the E5 lock. Service Code: Non-Software lock: A total of 10 one-time use keypad service codes are permitted and they are typically used to allow maintenance or vendors a single access. If the E5 is currently locked and a service keypad code is used on the lock, it will unlock. If the lock is already unlocked, the E5 will relock. Once programmed into the E5, these service keypad codes remain unless used or the lock is reset to the original manufacturer s defaults. Once a total of 10 unused service keypad codes are programmed in, the E5 will not allow any additional service keypad code entries until at least one of the existing service keypad codes are removed by using them. Service keypad codes do not have index numbers. Any number of service keypad codes up to 10 can be programmed into the non-software E5 at one time or just one at a time. trylocks.co Software Version E4 / E5: A total of 10 one-time use keypad service codes are permitted and they are typically used to allow maintenance or vendors a single access. If the E4 / E5 is currently locked and a service keypad code is used, the lock will unlock. If the lock is already unlocked, the E4 / E5 will relock. Once programmed into the E4 / E5, these service keypad codes remain unless used or the lock is reset to the original manufacturer s defaults. Once a total of 10 unused service cks.co Wheaton, IL Page 9 of 58 FAX: (630)

10 Section: Programming Guide Non-Software keypad codes are programmed in, the E4 / E5 will not allow any additional new service keypad code entries until at least one of the existing service keypad codes are removed by using them. Service keypad user codes do not have index numbers. Service keypad codes can only be programmed into the software version E4 / E5 one at a time for a total of 10 times. Non-Software E5 Lock: Index Number ssentryloc Users are automatically assigned an index number in the order that they are added to the E5, beginning at 001 and incrementing by one at every new user (that is, 001,002,003,004, etc.). This index number is required if you later want to delete a user from the lock. The maximum number of users is 299. You should keep track of what this index number is for each user as you enter them. There is no way to obtain the index number from the lock if you should later need it, so it is best to keep track of it while you enter the user codes. The index number is always expressed in 3 digits. Software Version E5: When the software version of the E5 is manually programmed from the keypad on the lock, users are automatically assigned an index number in the order that they are added to the E5, beginning at 001 and incrementing by one at every new user (that is, 001,002,003,004, etc.). Either the index number OR the user access code is required if you later want to delete a user from the lock. The maximum number of users is 299. You should keep track of what this index number is for each user as you enter them. There is no way to obtain the index number from the lock if you should later need it, so it is best to keep track of it while you enter the user codes. The index number is always expresses as 3 digits. Index numbers do not apply to the software version E4 / E5 when programmed with a personal computer, only when manually programmed from the keypad on the E4 / E5. trylocks.co Passage Mode: Non-Software or software E4 / E5 Lock: Different Types of Modes Passage mode allows the lock to remain in the last lock state it was used in. That is, if the lock is locked, it will remain so until a user unlocks it, then it will remain unlocked until a user relocks the lock. This condition will continue as long as the Lock is in a Passage mode. Programmed auto lock or unlock times can be applied while in Passage mode if desired. The effect on the lock state is the same as if a user key had been used to lock or unlock the E4 / E5. Passage mode can be applied, defeated, or removed by changes in mode via customer lock programming such as time schedules and lock out keys to mention a few. (Important note: When manually programmed via the keypad, the lock MUST exit passage mode for at least 1 minute around midnight to allow for the change of day. This limitation does not exist for locks programmed via PC software) cks.co Wheaton, IL Page 10 of 58 FAX: (630)

11 Storehouse Mode: Non-Software use E4 / E5: Section: Programming Guide Non-Software This is commonly also called a Lock-back mode and is the lock default mode. When in Storehouse mode, a valid unlock command, regardless of if it is from a user key code, ibutton, or a programmed scheduled auto-unlock command, the lock will unlock, then automatically relock itself in 5 seconds. This provides additional security in that no user can forget to re-lock the door. This unlock/auto-re-lock action will continue as long as the E4 / E5 remains in Storehouse mode. (The 5 second time delay between the unlock/auto-relock action is user adjustable on the software version E4 / E5 using 'function code 61' but is not user adjustable on the non-software E5.) ssentryloc Lockout Mode: Time: Date: Non-Software use E4 / E5: Lockout mode freezes the E4 / E5 in whatever the current lock status is. If the lock is currently locked, in lockout mode then it will remain locked regardless of normal program changes or user code key/ibutton use. Similarly, if the lock is currently unlocked, in lockout mode it will remain unlocked regardless of normal program changes or regular user keypad code / ibutton use. This status will continue until lockout mode is disabled. Time and Date Format (For non-software and software E4 / E5) All times are expressed in 24 hr time. Example: (8:30 am = 0830, 12 noon = 1200, 9:40 pm = 2140, etc.) trylocks.co Date is expressed as a 2 digit year followed by 2 digit month, followed by 2 digit day. Examples: = February 21st, 2011 or = September 15th, 2011). Note: Where the month or day of the month is a single digit a leading zero must be entered. Days of the week: When programming an E4 / E5 lock schedule by named day(s) of the week, scheduled days-ofthe-week are expressed in the following manner: Monday = Day 1 Friday = Day 5 Tuesday = Day 2 Saturday = Day 6 cks.co Wednesday = Day 3 Sunday = Day 7 Thursday = Day 4 Wheaton, IL Page 11 of 58 FAX: (630)

12 Section: Programming Guide Non-Software Programming via the keypad of an E4 / E5 lock requires entering the 'Master Code' number for the lock to allow the lock to enter a programming mode, a 'Function Code' number that lets the lock know what lock function you wish to program, and then entering the data for that function. The '#' key is used between these three groups of information to separate them and to inform the lock when you are finished entering information. This basic format is used for virtually every programming action. ssentryloc It is important when programming the lock that the keypad button presses be done promptly one after another, as hesitating for more than a few seconds between key presses will cause the lock to 'time out' and reject the entries. Should you make a mistake pressing the correct key while entering programming, simply press the * key to cancel, then start again from the beginning of that programming command. Remember also that the lock 'Master code' can never unlock or lock the E4 / E5 it only allows programming of the lock. Get Started Programming A full list of commands and function codes is listed in this guide. However, for most users only a handful of commands will be required to make the lock operate in the commonly used modes. Examples of the most common programming are provided at the end of the guide that you may customize as you wish. That said, much more complex operations are possible if required using the extended 'Function Codes' in this guide. The best way for a user to begin programming the lock is to first take the time to write a list of the desired lock operation, particularly of any schedules required for either automatic lock actions (auto lock / unlock) as well as a list of user schedules (if any) and desired user entry keypad codes and / or ibutton keys. From this you may pick out the required programming command(s) to create the lock action you want. trylocks.co Creating a detailed plan for how you want the lock to operate before attempting lock programming will avoid later frustration and confusion. Basic Functions How to change the 'Master code' (and not delete existing user codes) Function Code: 11# {#Master code#}+{11#}+{new master code#}+{new master code#} Note: Master code can NOT unlock the lock, only program the lock. How to change the 'Master code' (and delete all existing user codes) cks.co Function Code: 22# {#Master code#}+{22#}+{new master code#}+{new master code#} Wheaton, IL Page 12 of 58 FAX: (630)

13 Section: Programming Guide Non-Software Note: Master code can NOT unlock the lock, only program the lock. How to enable automatic daylight savings time changes (USA only) Function Code: 31# {#Master code#}+{31#} How to set the lock's internal date and time clock Function Code: 88# ssentryloc {#Master code#}+{88#}+{yymmddhhmm#} (year, month, day, hour, minutes) How to add one user code (no time restriction) Function Code: 01# {#Master code#}+{01#}+{user code# # #} How to unlock the lock with a valid user code Enter the user code, then # to finish {User code #} How to add one ibutton key (no time restriction) Function Code: 01# {#Master code#}+{01#}+{touch ibutton # #} Advanced Functions How to add multiple user code (no time restriction) Function Code: 01# trylocks.co {#Master code#}+{01#}+{user code(1)# # #}+{user code(2)# # #}+{user code3###} and so on How to add one user access code (with time / date restriction) Function Code: 01# {#Master code#}+{01#}+{user code#}+{yymmddhhmm#(start time)}+ {yymmddhhmm#(ending time)} How to add multiple user code (with time / date restriction) Function Code: 01# {#Master code#}+{01#}+{user code#(1)}+{yymmddhhmm#(start)}+ {yymmddhhmm#(ending time)} + {user code#(2)}+{yymmddhhmm#(start)}+ {yymmddhhmm#(ending)} and so on cks.co How to add multiple user ibutton key (no time restriction) Function Code: 01# Wheaton, IL Page 13 of 58 FAX: (630)

14 Section: Programming Guide Non-Software {#Master code#}+{01#}+{ibutton(1)# #}+{ibutton(2)# #} and so on How to add user code + ibutton key as dual user (no time restriction) Function Code: 01# {#Master code#}+{01#}+{user code#}+{touch ibutton# #} (To access door: touch ibutton key + user code # ) How to add one ibutton key (with time / date restriction) ssentryloc Function Code: 01# {#Master code#}+{01#}+touch {ibutton}+{yymmddhhmm#(start time)}+ {yymmddhhmm#(ending time)} How to add multi-ibutton key (with time / date restriction) Function Code: 01# {#Master code#}+{01#}+touch {ibutton key(1)}+{yymmddhhmm#(start)}+ {yymmddhhmm#(end time)}+ touch {ibutton key(2)}+{yymmddhhmm#(start)}+ {yymmddhhmm#(end time)} and so on How to disable one user code or ibutton key with index# Function Code: 02# {#Master code#}+{02#}+{index #} How to enable one user code or ibutton key with index# Function Code: 03# {#Master code#}+{03#}+{index code#} How to enable passage mode and schedule (lock back when the passage mode end) trylocks.co Function Code: 15# {#Program#}+{15#}+{Schedule days}+{#}+{begin time & ending time#} How to disable passage mode Function Code: 16# {#Master#}+{16#} How to enable LED blink light (on & off) Function Code: 18# {#Master code#}+{18#} How to disable daytime saving cks.co Function Code: 32# {#Master code#}+{32#} How to set up one time service code (up to 10 service codes) Wheaton, IL Page 14 of 58 FAX: (630)

15 Function Code: 33# Section: Programming Guide Non-Software {#Master code#}+{33#}+{service code(1)#}+ {service code(2)#}+ and so on How to delete user code or ibutton key with index # Function Code: 44# {#Master code#}+{44#}+{index#} How to schedule a user code ssentryloc Function Code: 45# {#Master code#}+{45#}+{user code#}+{schedule days#}+{begin time & ending time#} How to schedule a user ibutton key Function Code: 45# {#Master code#}+{45#}+{touch ibutton to reader}+{schedule days#}+{begin time & ending time#} How to schedule a user with a user code AND an ibutton key Function Code: 45# ı#master code#}+{45#}+{user code#}+{touch ibutton to reader}+{schedule days#}+ {begin time & ending time#} How to DELETE an existing user code / ibutton key (without index number) Function Code: 46# {#Master code#}+{46#}+{user code#}(or ibutton key w/o trailing # key) NOT available on non-software locks with v4.1 or earlier firmware How to RE-ACTIVATE an existing deactivated user code / ibutton key (without index number) trylocks.co Function Code: 47# {#Master code#}+{47#}+{user code#}(or ibutton key w/o trailing # key) How to DE-ACTIVATE an existing active user code / ibutton key (without index number) Function Code: 48# {#Master code#}+{48#}+{user code#} (or ibutton key w/o trailing # key) How to enable auto-unlock function Function Code: 64# {#Master code#}+{64#} cks.co How to setup auto-unlock time (it will auto unlock the door every day at assigned time) Function Code: 63# {#Master code#}+{63#}+{hhmm#} Wheaton, IL Page 15 of 58 FAX: (630)

16 How to disable auto-unlock function Function Code: 65# {#Master code#}+{65#} How to enable auto-lock function Function Code: 67# {#Master code#}+{67#} ssentryloc Section: Programming Guide Non-Software How to setup auto-lock time (it will auto lock the door every day at assigned time) Function Code: 66# {#Master code#}+{66#}+{hhmm#} How to disable auto-lock function Function Code: 68# ı#master code#}+{68#} How to enable / disable Lock-out (lock out all users if enabled) Function Code: 99# {#Master#}+{99#} Basics rules of programming schedules User Schedule Programming Examples Function Codes used: 01# / 15#/ 31# 45# / 63# / 64# / 66# / 67# / 88# General rules (follow the order for best results): trylocks.co Make sure you have already entered new (non-default) Master code 1 st -- enable daylight savings mode (USA only) 2 nd -- set up date & time (use function code 88) 3 rd -- adding user code or ibutton key in advance with 01# or use 45# for an existing user 4 th -- program schedule days (as below) Day Chart This chart defines day numbers to be used for scheduling Monday = Day 1 Friday = Day 5 Tuesday = Day 2 Saturday = Day 6 cks.co Wednesday = Day 3 Sunday = Day 7 Thursday = Day 4 Wheaton, IL Page 16 of 58 FAX: (630)

17 Section: Programming Guide Non-Software Note: All examples below use '23456' as a sample master code. Substitute whatever particular master code you selected during initial lock setup How to add a new 'user code' with a scheduled access time AND date restriction Example: A business wants to create a new user 2222 and grant them access between 8/20/2012 at 8:30am and voiding user 2222 access after 8/20/2013 at 5:30pm. (remember, 24 hr time) ssentryloc Enter: #23456#01#2222# # # #23456# 01# 2222# # # Master Code Function code User code Start date/time End date/time 0800=8:00AM, 1730=5:30PM How to add a new 'ibutton' user with a scheduled access time AND date restriction Example: A business wants to create a new ibutton user and grant them access between 8/20/2012 at 8:30am and voiding this user access after 8/20/2013 at 5:30pm. (remember, 24 hr time) Enter: #23456#01#<Touch ibutton to reader> # # trylocks.co #23456# 01# Touch ibutton # # Master Code Function code User ibutton Start date/time End date/time How to program an existing 'user code' with a scheduled access time restriction Example: A business wants to grant existing key code user 2222 access Monday, Wednesday, and Friday between 8:30am and 5:30pm. (remember, 24 hr time) Enter: #23456#45#2222#135# # #23456# 45# 2222# 135# # cks.co Master Code Function code User ibutton Mon/Wed/Fri Start time End Time Wheaton, IL Page 17 of 58 FAX: (630)

18 Section: Programming Guide Non-Software How to program an existing 'ibutton' user with a scheduled access time restriction Example: A business wants to grant an existing ibutton user access Monday, Wednesday, Friday between 8:30am and 5:30pm. (remember, 24 hr time) Enter: #23456#45# <Touch ibutton to reader> + 135# # ssentryloc #23456# 45# Touch ibutton 135# # Master Code Function code User ibutton Mon/Wed/Fri Start time End Time trylocks.co cks.co Wheaton, IL Page 18 of 58 FAX: (630)

19 Lock Schedule Programming Examples Section: Programming Guide Non-Software How to program a basic automatic command for 'passage mode' on a weekly schedule Example: A business wants to schedule the lock to enter passage mode Monday through Friday at 8:30am and return to 'Storehouse mode' at 5:30pm. After 8:30am a valid user can unlock the lock. It will then stay unlocked until 5:30pm unless a valid user re-locks the door. At 5:30pm the lock will automatically re-lock by itself. After 5:30, valid users can still open the lock, however the lock will automatically re-lock itself 5 seconds later to prevent the door from accidentally being left unlocked. (remember, 24 hr time) ssentryloc Enter: #23456#15#12345# # #23456# 15# 12345# # Master Code Function code Mon-Fri Start time End Time If the desire is for the lock to be in 'Passage mode' at all times, ' Passage mode' times should be from 12:01am (0001) to 11:59pm(2359). This is because the lock MUST be in 'Storehouse mode' when the date changes at midnight each night, if only very briefly. Since the default lock mode is 'Storehouse mode', the 2 minute gap in the times for 'Passage mode' around midnight allows this to occur. Practical program to automatically unlock / lock on days at particular times Example: A business wants to have the lock automatically unlock at 8:00am and re-lock at 5:00pm Monday-Friday on a connecting door, without any user intervention. (remember, 24 hr time) trylocks.co Enter: #23456#63#0800# Enter: #23456#64# Enter: #23456#67# Enter: #23456#15#12345# # automatically unlocks door at 8:00 am enables auto-unlock feature enables auto-lock function set passage mode start at 7:59am, ending at 5:00pm Note: The reason for 'Passage mode' to start at 7:59am and 'Auto-unlock' to occur at 8:00am is because the lock must already be in 'Passage mode' before the 'Auto-unlock occurs, otherwise the lock would re-lock itself 5 seconds later. cks.co The lock needs at least 1 minute between command times. It is not required to use an 'Autolock' time command in this one case, as the lock will lock itself without an 'Auto-lock' command any time it leaves 'Passage mode' and enters the default 'Storehouse mode'. Wheaton, IL Page 19 of 58 FAX: (630)

20 Section: Programming Guide Non-Software How to program a basic automatic lock command for every day at a particular time #Master code#67# #Master code#66#{lock time} Example: A business wants the lock to automatically lock at a 12:30pm every day for lunch. (remember, 24 hr time) ssentryloc Enter: #23456#67# Enter: #23456#66#1230# enables auto-lock feature sets auto-lock time to 12:30pm How to program a basic automatic unlock command for every day at a particular time #Master code#64# #Master code#63#{unlock time} Example: A business wants the lock to automatically unlock at 1:00am every day after lunch. (remember, 24 hr time) Enter: #23456#64# Enter: #23456#63#1300# enables auto-unlock feature sets auto-unlock time to 1:00pm trylocks.co Important note: If the desire is for the lock to unlock at 1:00pm and stay unlocked, the lock must be also programmed to be in 'Passage' mode prior to that time, usually at business opening time in the morning. Otherwise the lock would re-lock itself 5 seconds later, because the default lock mode is 'Storehouse mode'. Additional notes for continuous lock 'Passage mode' programming Should you desire that the lock remain in 'Passage mode' at all times, that is not quite possible. However, if the lock is programmed to leave passage mode and go to the default 'Storehouse mode' for a minute or so at midnight each night before going back to 'Passage mode' for the next day, that can be done. This is required because the lock must be in the default 'Storehouse mode' at the change of the day of the week at midnight, if only briefly. This is not the case when E4 / E5 software locks are used with PC computer programming, only when manually programmed with the keypad. cks.co Wheaton, IL Page 20 of 58 FAX: (630)

21 Trouble Shooting Guide Problem Possible Reason Solution ibutton Key is not working Time restricted key or invalid user ssentryloc Section: Programming Guide Non-Software 1. Make sure user was properly programmed or change time restrictions on particular ibutton Red light is on and three beeps Batteries low 1.Change Batteries 2. Reset the lock time and date (function 88#) Green light is on and two beeps, but motor is not running Temporary Key Code is not working Lock doesn t accept any valid ibutton key Will changing battery erase the key list After changing the battery, codes stop working No power to lock motor Access code is expired or lock time is incorrect Lock is in 'Lockout' mode No it will not Internal lock clock time is lost Make sure the motor wire is firmly connected to the PCB and that wire is not pinched or damaged by latch Check / set the time / date inside lock or issue new temporary code Issue a new Lockout Key to release the lockout mode. The key list and timetables are stored inside the flash memory, disconnecting the batteries cannot erase the non-volatile, solid-state flash memory. trylocks.co Set the lock time and date using function code 88. User codes and lock schedules are still remembered, but lock doesn't know current time / date. cks.co Wheaton, IL Page 21 of 58 FAX: (630)

22 Foreword Programming Guide Software Version General Overview ssentryloc About This Manual This manual is designed for users of Eternity E4 and Eternity E5 with Software. All installation, setup, operational information, procedures, screen captures, and other relevant materials are contained in this manual. Safety Warnings and Cautions When handling a printed circuit board (PCB), guard against possible static discharges by touching a grounded object BEFORE touching the board. Static shock could cost unexpected damage of the board. Design Change Disclaimer Due to design changes and product improvements, information in this manual is subject to change without notice. UAccess, LLC assumes no responsibility for any errors that may appear in this manual. Reproduction Disclaimer Neither this manual nor any part of it may be reproduced, photocopied, or electronically transmitted in any way without the written permission of UAccess, LLC. trylocks.co Important Information Manufacture Default Code Setting: 1. Default Setting for Log-in User Name / Password is: dallas / ibutton 2. Operator Password: The default operator password is (8 digit Zeros) 3. System Facility Code: The default System password is (6 digit Zeros). Once changed, it cannot be changed back to the manufacturer's default. LED and Audio Indicators: 1. Program Mode: LED indicating GREEN, audio end with two beeps (Successful) 2. Program Mode: LED indicating RED, audio end with one beep (Fail) 3. Key Access Mode: LED indicating GREEN, audio end with two beeps (Valid Access) 4. Key Access Mode: LED indicating Red, audio end with one beep (Fail) cks.co 5. Unlock Mode: LED flashing GREEN, lock is in unlock mode 6. Lock Mode: LED flashing RED, lock is in lock mode Wheaton, IL Page 22 of 58 FAX: (630)

23 Important ibutton Keys: Overview: ibuttons are NOT normally magnetic and will not affect credit cards, watches, or pacemakers. They typically do not emit radiation of any kind. Stainless steel ibuttons are normally pressed into colored plastic tags at the factory to make identification and use easier. Key-fob tag colors available are white, yellow, pink, red, orange, blue-green, dark-green, purple, or black. Since all stainless steel ibuttons are identical in size and shape they can be provided in any of the available color key-fob tags by special order. However, there are various default colors for various key types if a particular color isn't specified when ordered from the manufacturer or distributor. ssentryloc If in doubt as to the actual key type, you can identify the ibutton model number by looking on the metal end cap with a magnifying glass. The model number beginning with 'DS-' is imprinted there. Some ibuttons contain special functions such as digital memory or real-time clocks, while others merely identify specific users. The following list contains the most commonly used ibuttons: 1. DS1990 User Key, each key has a digital serial number that cannot be duplicated. Once programmed into lock memory as a valid user, can be used to lock or unlock locks. (Default key-fob colors: red, yellow, black, orange, dark-green, brown) 2. DS1904 or DS1994 Contain an on board real time clock used to reset the lock internal clock. Either one can be generally used interchangeably with the locks and software (Default key-fob color: Blue-Green) 3. DS1977- Program Key. Use to move programming to / from locks (Default key-fob color: Purple) trylocks.co cks.co Wheaton, IL Page 23 of 58 FAX: (630)

24 Software Specifications E5 Software vs. Non-Software Specifications Description Software Non-Software Audit Trail Yes. 3,000+ No ssentryloc Users Timed Operation Yes Yes Remote Access Yes No Storehouse/Passage Mode Yes Yes One Time User Yes Yes Software Package Yes No Lock from Inside No No Set Up Method Software Keypad Daylight Saving Yes Yes Lock Out Function Yes Yes trylocks.co cks.co Wheaton, IL Page 24 of 58 FAX: (630)

25 E4 Software vs. Non-Software Specifications Description Software Non-Software Audit Trail Yes (3000 entries) N/A ibutton Key Users 299 (Combined ibutton and code) 299 (Combined ibutton and code) Keycode Users See above See above ssentryloc Timed Operation Yes Yes Auto Lock/Auto Unlock 16 time schedules limited fixed time schedules Passage Mode 16 time schedules Single time schedule Time Shift User 16 time schedules Single time schedule Remote Access Yes Yes Storehouse/Passage Mode Yes Yes One Time Use Yes Yes ibutton User Yes Yes Permanent Code User Yes Yes Remote Code User Yes Yes trylocks.co One-Touch Lock from Inside Yes Yes Daylight Saving Yes Yes Lock Out Function Yes Yes User Key Assignment Method Software + Programming Key Keypad Software Package Yes (Optional) cks.co Wheaton, IL Page 25 of 58 FAX: (630)

26 Software Setup Eternity 3.7 Software Guide The Eternity PC Software works the same for both Eternity E4, Eternity E5, E5TKSCS, E5TKSBS, Eternity E2, E2TMKP, and EDC700 series door controller systems. (E2TMKP and EDC700 have differences in reset button processes for new lock setup but are otherwise much the same.) ssentryloc Operating System Eternity 3.7 software is compatible with Microsoft Windows 2000/XP/Vista/Win7. All software must be installed using Windows administrator account, but all level Windows users can use the program. Failure to install the applications may result in error messages and an incomplete installation. For Vista/Win7 users, you may need to run the application each time as an administrator. Installing 1-Wire USB Driver First 1. Insert installation CD. Note: On most computers, the Autorun program should launch automatically. If it does not, select Start/Run, browse to CD-ROM drive, select the Auto-run file. 2. Select 1-Wire USB Driver Installation, the Setup Wizard will guide you through the steps to install the program. 3. The License Agreement screen displays. 4. Select 'I Agree' and then 'Install' to start installation. 5. Select 'Finish'. The 1-Wire USB Driver Installation is now complete. trylocks.co 6. Plug the 1-Wire USB device into the USB port on your computer 7. Check the time and date on your computer and correct if needed. Note: The time and date in your computer is used to set the clock in the locks, so any errors in the PC time will also be loaded into the locks. Installing the ikeypad Software 1. Select Eternity Software Installation. The Auto installer will guide you through the steps and it is suggested to create the shortcut ikeypad on your desktop. 2. Select 'Next' until the installation finishes. cks.co Wheaton, IL Page 26 of 58 FAX: (630)

27 Starting the ikeypad Software ssentryloc Program Log-in: User Name and Password Changing / Adding Users and Passwords trylocks.co Note: In order to apply a particular password to a new operator, select 'Change Operator Password' and enter the default new operator password of ' ' (8 zeros). You may then enter the new password for that operator. cks.co Wheaton, IL Page 27 of 58 FAX: (630)

28 Changing the System Facility Code (MANDATORY) The default system facility code is (6 Zeros). It Is MANDATORY to change and remember the facility system code entered when the user is ready to first use this software. This is NOT a user password. It allows the locks to respond only to your particular software, not someone else who might have a different copy of the same software (created for security purposes). Other copies of this program cannot access locks that have been programmed using a different facility code unless the locks have been completely reset to factory new conditions first as a security measure. (Failure to remember what the facility code becomes may make future computer 'backups' of the software not function with the locks.) The PC software facility code can also be later changed via the 'Other' menu, then 'System Configuration' menu. This is STRONGLY DISCOURAGED ONCE THE DEFAULT FACILITY CODE IS CHANGED DURING INITIAL SOFTWARE SETUP AND INITIAL NEW LOCK PROGRAMMING, as this will make the software unable to address locks that were set up using the original facility code. ssentryloc Access Control Management trylocks.co Lock Setup New Lock Set Up Overview: Initialize the lock back to the manufacture default settings. Sets the facility security code and current time and date into the lock. Set the lock clock to enable or disable the Daylight Saving time functions Set the default Lock Mode to 'Classroom' Mode (sometimes also called 'Passage' mode) or 'Storehouse' Mode. Set LED Blinking about once every 10 seconds or off for better battery life. cks.co Wheaton, IL Page 28 of 58 FAX: (630)

29 Steps to set up a new lock: 1. Connect the USB blue dot receptor to the computer USB port. 2. Log in to the software. 3. Snap the program key (DS1977) onto the USB blue dot receptor and Click 'Lock Management' 4. Click on 'Setup New Lock' from the drop-down menu (see below). Select the default options you want by clicking on the check boxes provided. 5. Select 'Issue Key' from the bottom of the menu and answer 'OK' to any pop-up warnings. 6. Hold the reset button on the lock until there are two beeps and a solid green light; when the LED starts blinking green, release the reset button and immediately press the # key. When the lock stops flashing and beeps 3 times, the lock has been reset to factory defaults. 7. Press the reset button once quickly and release it. The lock will light the LED green and beep twice. 8. While the LED is still lit, touch the program key to the ibutton reader on the lock. There will be two more beeps to indicate that the lock confirmed the information upload from the program key. The lock will now have been initialized and the lock will have recorded its lock identification number on the program key. ssentryloc trylocks.co cks.co Wheaton, IL Page 29 of 58 FAX: (630)

30 ssentryloc trylocks.co cks.co Wheaton, IL Page 30 of 58 FAX: (630)

31 An Alternative way to enter existing locks to the system: Overview Selecting the 'Lock Management' icon on the main menu, then clicking on the 'Lock Setting' from the drop-down menu is an alternative way to add existing locks to the system if you already have initialized them using the same Facility Code at some point and have the lock ID number, but have a need to manually enter them again. We recommend users keep the lock ID on file after the new lock setup so that you can manually input a lock profile into the system if ever needed. Note: You cannot change the user assignments from the 'Lock Setting' screen. User assignments to a given lock are made through the 'User Code Management' screen. ssentryloc trylocks.co cks.co Wheaton, IL Page 31 of 58 FAX: (630)

32 Editing (modifying) existing lock information or configuration ssentryloc trylocks.co cks.co Wheaton, IL Page 32 of 58 FAX: (630)

33 User Setup Setting User Access codes and/or ibuttons Overview: Add/Edit user information Select 'User Code Management' from the main menu. Then select 'User Settings' from the drop down menu. To add an ibutton / key code user, click Add User button in the key setting menu (or 'Modify' if you wish to change an existing user) For new users, enter the name information and, if desired, the 'Title', 'Department' and 'Address'. To add ibutton user, click 'OK' and snap a user ibutton key into the USB blue dot receptor. Click on the empty field of 'Serial ID', the ibutton key ID will be detected by the system and automatically entered. To add key pad code user, check the 'Key Code User' and click 'OK'. Type in user code under Key Code field. If the either user key type or name already exists in the system, the software will pop up a warning. To enter a 'Complex' user (Requires that the user use BOTH an ibutton AND a keypad code every time for extra security) click on 'Complex User', then 'OK'. ssentryloc For any of the three user types, enter the user profile as follows: trylocks.co cks.co Wheaton, IL Page 33 of 58 FAX: (630)

34 Enter the specific user information: First name: Input the first name of the key owner. Last name: Input the last name of the key owner. Status: Active or Inactive User (reserve for future use). Department: User can input a new name in the field. The new name will be saved to the Department list once the data saved Note: Not a required data entry. Title, address: Can be entered as the key owner profile. Note: Not a required data entry. ssentryloc trylocks.co cks.co Wheaton, IL Page 34 of 58 FAX: (630)

35 Assigning Users to a Single Lock Overview: This menu is used to assign ibutton keys and user codes to one lock. Select lock from lock name list Change Time Shift, Activation / Expiration, or Holiday (Exception) settings to be assigned to the lock Click on the Selected column to assign users you desire for the lock Snap in DS1977 programming key into the USB blue dot receptor Click 'Issue Key' Complete the lock programming by touching the programming key to the target lock reader until you hear a double beep. ssentryloc trylocks.co cks.co Wheaton, IL Page 35 of 58 FAX: (630)

36 Multiple Lock Assignment Overview: This process is to assign a key list to multiple locks at one time. Up to 8 locks can be assigned to each programming key, with a maximum of 114 keys total. The process is similar to single lock programming, but allows limited programming of multiple locks without returning the DS1977 program key to the USB blue dot receptor between each lock. The limited memory available in the DS1977 key means that you may have to use 'Single Lock' programming to pass the time schedules database tables to the locks if they have been changed. The data tables of all the available 'Time Shift', 'Holiday', 'Activation', and 'Expiration' are only passed to locks during 'Single Lock' programming process. As long as that data has not changed, you may assign these already existing time-group tables to locks and users using the 'Multi-Lock' programming menu as desired. ssentryloc To Use Multi-Lock Programming: trylocks.co cks.co Wheaton, IL Page 36 of 58 FAX: (630)

37 ssentryloc trylocks.co Take the DS1977 program key and touch it to the reader of each of the target locks. There is no need to return the program key to the PC in between every lock. Hold the key to each lock until the chirping noise stops and the lock beeps twice. The order in which the locks are programmed does not matter. A maximum 114 keys can be assigned (total) at one time using Multi-Lock programming. cks.co Wheaton, IL Page 37 of 58 FAX: (630)

38 Copy Lock Setting Overview: This is a very useful tool when multiple locks have identical setting such as key list and/or timetable. After enrolling all the locks and users into the system, assign timetables and assign user keys/codes to one lock, then use this lock as model lock. Double click on the field of Select Model Lock, and select the lock from the pop up screen. Check the Selected boxes and issue the program key using the USB blue dot receptor. Complete the process by touching the programming key to each of the selected lock readers and hear the double beep conformation from each lock. ssentryloc Advanced Access Control Management Time Schedule Settings trylocks.co Time shift, activation/expiration, and exception date settings can be applied by using the 'Time Shift', 'Holiday Schedule', and the 'Activation / Expiration' menus to set the time periods you want, then by selecting the desired timing groups during later key assignments to locks with 'Single Lock Programming' or 'Multi-Lock Programming'. Time Shift Setting This function is used to set the restricted time period(s) for user keys, which prevents unauthorized or unwanted personnel from entering the facility during off-hours. The beginning time and ending time of each days period can be added based on user group s permission. There are 16 Time Shift Groups in total and up to 7 settings in each group. This can allow for different schedules for each day if you wish. The first group is 'No Limit'. This is a default setting for each new key and this group cannot be modified. Other groups can be modified and assigned if the 'No Limit' group is not what is desired. cks.co Wheaton, IL Page 38 of 58 FAX: (630)

39 ssentryloc To add or modify each time period in a time group: Select the group number you want from the left side window, then click on Add, Modify, or Delete button to edit the settings in the right side window. Note: Group 1, 'No Limit' is the default and cannot itself be modified. Here is the example for Time Shift Group 2: A company wants to set the Group 2 Shift to have access from Monday to Friday 8:00am to 5:00pm, and no access allowed on Saturday and Sunday. Select 'Add', then set the beginning, end, and day of week you desire. Select 'Save' after each of the groups you are entering. trylocks.co cks.co Wheaton, IL Page 39 of 58 FAX: (630)

40 ssentryloc trylocks.co cks.co Wheaton, IL Page 40 of 58 FAX: (630)

41 ssentryloc Once all the setting(s) desired are entered and saved, click the 'Quit' button to return to the previous menu trylocks.co cks.co Wheaton, IL Page 41 of 58 FAX: (630)

42 Lock Time Scheduled Operation Setting Overview: This function is used to set the lock automatically unlocked, locked, storehouse mode, or passage (also called classroom) mode at the desired time. The schedules of various automatic operations of the lock(s) are entered into groups in the 'Lock Schedule' menu, found by clicking on the 'Lock Management' menu icon and selecting 'Lock Schedule'. ssentryloc There are 16 Timed Operation Groups in total and up to 16 settings in each group. The first setting by default is No Limit Classroom Mode. In other words, the lock will stay in Classroom (Passage) mode all the time. The second setting by default is No Limit Storehouse Mode. In other words, the lock will, at all times, re-lock automatically shortly after the user unlocks the lock). Any particular lock may only have one group schedule assigned to it at a time, but conversely one group can be assigned to as many locks as you may desire. The time tables for lock schedules are set here, but not assigned to specific locks in this menu. trylocks.co There are 4 basic types of lock actions you can schedule by day and time, and by lock: Storehouse Mode: In this mode, the lock will lock back in a few seconds ( seconds). Classroom (Passage) Mode: In this mode, the lock does not lock back. The use of a valid ibutton or code simply makes the lock go from unlocked to locked or locked to unlocked. Lock Mode: In this mode, the lock will automatically lock at the setting time. Unlock Mode: In this mode, the lock will automatically unlock at the setting time. cks.co Wheaton, IL Page 42 of 58 FAX: (630)

43 ssentryloc trylocks.co Repeat this process until the entire schedule you want is listed for that Lock Status ID has been entered, then select the 'Quit' icon from the top of the screen. Assigning a particular Status schedule group to a particular lock Overview: The automatically timed operation settings are applied to individual locks via the 'Lock Management' 'Lock Setting' menu by first selecting the lock you wish to apply the schedule group to, using the 'Modify' icon at the top of the menu, then changing the 'Lock Status' section to match the schedule you want. cks.co Wheaton, IL Page 43 of 58 FAX: (630)

44 ssentryloc trylocks.co cks.co Wheaton, IL Page 44 of 58 FAX: (630)

45 Activation / Expiration Date Setting Overview: This function is used to set the activation date and expiration date of valid keys. The first group is a default setting where no time limit is applied to the user. The rest of groups can be set to an activation date and expiration date by the operator of the software. Only one group can be applied to a particular user on a particular lock. However, different locks can have different groups applied to that same user. In other words, you can control the access of a user to a particular door without restricting that same user from access to a different door. ssentryloc trylocks.co cks.co Wheaton, IL Page 45 of 58 FAX: (630)

46 ssentryloc trylocks.co cks.co Wheaton, IL Page 46 of 58 FAX: (630)

47 Holiday / Exception Date Setting Overview: This function is used to set or restrict access during periods such as holidays, facility shutdowns, and vacation periods. The first group set as 'No Limit' default setting. The holidays can be set as a single day or multiple days. The selected user ibutton keys or codes will be restricted from access for all of the exception dates entered in this list. ssentryloc trylocks.co cks.co Wheaton, IL Page 47 of 58 FAX: (630)

48 ssentryloc Lock Management trylocks.co Overview: The lock management utilities help you manage both the locks themselves and the records the locks keep. It primarily allows you to create and issue DS1977 program keys that can, among other things, set lock details such as time and date, lock-back delay for storehouse mode, special temporary user keys and keypad codes, and get information FROM locks to compare to the data cks.co Wheaton, IL Page 48 of 58 FAX: (630)

49 in this program's database. Set Parameter Key Overview: This process can set many lock parameters, such as LED 'Blink', 'Lock Back Delay Time', Set 'PC Time' (adjust lock time to a user set future time), and enable Daylight Saving time modes. To set the lock parameters: Select the function you want to change, snap the DS1977 program key into the USB blue dot receptor, then press the Issue Key button. Take the DS1977 program key to the lock and touch it to the lock reader until it beeps twice to set the parameters into the lock. (Use 'Set Time' key menu for 'normal' lock time setting) The 'PC Time' function is sometimes used to set the time of a lock when a DS1904/1994 time set key is not available. It allows the user to program a locks' clock to a future time or date using only the regular DS1977 program key. In doing so, it is possible to allow for the natural delays in physically taking the program key to the lock you desire to set the time on. If the lock is close by the PC, you can just click on the check box and the PC's clock current time and date will be used. ssentryloc trylocks.co cks.co Wheaton, IL Page 49 of 58 FAX: (630)

50 Set Time Key Overview: This process uses a DS1977 program key and a DS1904 (or DS1994) ibutton key to set the real time and date of the lock. Follow the on screen instructions to first 'Issue' the DS1977 key to 'allow' the lock to accept a time setting, then 'Issue' the DS1904 (or 1994) time set key. Apply first the DS1977 program key to each lock, then apply the DS1904 (or 1994 time) time set key to each lock. The DS1904/1994 key has a real-time clock inside that continues to run, so that even if there is delay at getting to a lock the time will still be right when applied to the lock. ssentryloc trylocks.co Tip: Other than DS1904/1994 real time key, just the DS1977 program key can also set the time of the lock. This is just a 'snap-shot' of the time however. Using just the program key set will cause some time errors since programming the key and programming the lock will take some time, particularly if there is a long distance between the computer and the lock. We recommend using cks.co Wheaton, IL Page 50 of 58 FAX: (630)

51 the DS 1904/1994 real time key if the delay in applying the key to the lock is excessive. Get Information Key Get Information Key is a useful tool to retrieve the existing information from a lock, such as: user key list, lock time, lock mode, lock / user group schedules, lock ID, or battery voltage. To get the lock information, snap the DS1977 program key into the USB blue dot receptor, click the Issue Key button, and then press the program key to the lock itself. The lock will make a series of chirping sounds, and when it is finished it will beep twice. Remove the program key and snap it into the USB blue dot receptor. Press the Read Key button to read the information. Using the tabs along the top of the information screen, you can compare the information inside the lock to the information in the PC program. ssentryloc trylocks.co cks.co Wheaton, IL Page 51 of 58 FAX: (630)

52 Lockout Key Overview: Lockout forbids all assigned keys/codes from operating the lock. Apply any Lockout key to put the lock in Lockout Mode, and apply again to release the Lockout Mode. To apply the key, snap the program key into the USB blue dot receptor, select open door or close door, press the Issue Key button, and then press the program key to the lock to set the Lockout Mode. There are two types of Lockout Modes. ssentryloc trylocks.co One-Off key/one-off Code Overview: These are two types of One Time User: one time service key using the DS-1977 programming key or keypad codes (up to 10) One-Off Key Step1: Select locks from Lock List. Step2: Issue key. This key will immediately work on the selected lock one time only. (No need set up on the lock) cks.co Wheaton, IL Page 52 of 58 FAX: (630)

53 ssentryloc One-Off Code Enter up to 10 'One-Off ' codes in the list, then use the DS1977 programming key to issue programming and assign the codes to each lock. To set the codes, snap the program key into the USB blue dot receptor, press the 'Issue Key' button, and then press the program key to the lock reader until the lock beeps twice to set the codes. You may then use the keypad code(s) to open a lock(s) a single time. Enter the 'One-Off' one-time keypad codes you wish, then click on 'Save'. Click on the 'Issue Key' to apply the changes to the DS1977 program key. Press the program key to each lock you want to have these 'One- Off' keypad codes trylocks.co cks.co Wheaton, IL Page 53 of 58 FAX: (630)

54 Audit Trial Overview: This function allows you to download the user records from locks o the PC program for your records or to export to Microsoft 'Excel' files. ssentryloc trylocks.co cks.co Wheaton, IL Page 54 of 58 FAX: (630)

55 ssentryloc History Lock Audit History trylocks.co Overview: The Audit Trail History is a way of keeping a complete record of lock activities from the Audit Trail function. cks.co Wheaton, IL Page 55 of 58 FAX: (630)

56 ssentryloc Here s how to change your view of the saved data: Click on which 'Query By' type you desire, use the pull-down arrows and select the key words/date you want. In 'Order By' check the records order you desire. The default is open lock time. Click the 'Search' button, the records will appear on screen. Click 'Clear' to clear the entire contents of the PC audit history database only. trylocks.co Note: Using the 'Clear' function only clears the PC database Audit History records, not lock memory of audit trails. There is NO facility in this software to clear audit trail information from locks themselves except by completely re-initializing a lock with the reset button and performing a new lock setup. Locks themselves can generally hold about 3200 entries in memory per lock, after which the oldest entries are automatically deleted inside the lock to make room for new entries. This is handled internally to the lock itself and not by the PC software. cks.co Wheaton, IL Page 56 of 58 FAX: (630)

57 Operator Log Overview: This function allows usage tracking of the operator of the PC software ssentryloc trylocks.co cks.co Wheaton, IL Page 57 of 58 FAX: (630)

LockState RL 4000 User Guide

LockState RL 4000 User Guide LockState RL 4000 User Guide www.resortlock.com Table of Contents Section 1: General Overview 1. Foreword... 3 2. Important Information.. 3 3. Software Installation.. 4 Section 2: Initial Lock Setup Manual

More information

UCA, INC. ACCESS CONTROL SOLUTION ETERNITY USER GUIDE. Version 2.1

UCA, INC. ACCESS CONTROL SOLUTION ETERNITY USER GUIDE. Version 2.1 UCA, INC. ACCESS CONTROL SOLUTION ETERNITY USER GUIDE Version 2.1 Table of Contents Eternity User Guide Chapter 1 System Information 1.1 Installation Diagram 1.2 Important Information Model Spec Manufacture

More information

ibutton Solo Setup Instructions

ibutton Solo Setup Instructions ibutton Solo Setup Instructions TimePilot Corporation, Batavia, Illinois 60510 www.crossoverlock.com TimePilot Corp., all rights reserved. Part No. 80022160 TimePilot ibutton Solo Lock Manual Introduction

More information

Ritenergy Pro. Access Control Systems. Manual Programming Guide. (Firmware Version 3.XX) 1 Introduction Programming Guide ritelock.

Ritenergy Pro. Access Control Systems. Manual Programming Guide. (Firmware Version 3.XX) 1 Introduction Programming Guide ritelock. Ritenergy Pro Access Control Systems (Firmware Version 3.XX) Manual Programming Guide 2010 Ritenergy International, LLC All Rights Reserved 1 Introduction Programming Guide ritelock.com INTRODUCTION The

More information

U-FLASH Setup Guide U-FLASH.

U-FLASH Setup Guide U-FLASH. U-FLASH Setup Guide Thank you for purchasing the U-FLASH. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,

More information

Security Door Controls

Security Door Controls Security Door Controls 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com PROGRAMMING INSTRUCTIONS E72K-A CIVIC SERIES

More information

Ritelock Pro. icode Programming Guide. (Version 1.XX) 1 User Guide Ritenergy International, LLC

Ritelock Pro. icode Programming Guide. (Version 1.XX) 1 User Guide Ritenergy International, LLC Ritelock Pro (Version 1.XX) icode Programming Guide 1 User Guide Ritenergy International, LLC TABLE OF CONTENTS RITELOCK PRO PROGRAMMING GUIDE 3 System Requirement 3 System Components 3 Programming with

More information

Visit us on the World-Wide Web at Programming Guide. Controller Boards

Visit us on the World-Wide Web at   Programming Guide. Controller Boards Visit us on the World-Wide Web at www.chamberlain.com PRO Systems Programming Guide Controller Boards -106 & -107 PROKey PROCard TABLE OF CONTENTS INTRODUCTION About the PRO System................................3

More information

ITEM: Digilock ATS - Recess Mount, No Pull Handle, Brushed Nickel, Black for 3/4" Door BRAND: Digilock $138.3

ITEM: Digilock ATS - Recess Mount, No Pull Handle, Brushed Nickel, Black for 3/4 Door BRAND: Digilock $138.3 Specifications PRODUCT #: DLATS619013X ITEM: Digilock ATS - Recess Mount, No Pull Handle, Brushed Nickel, Black for 3/4" Door BRAND: Digilock SOURCE FOR PURCHASE: SpaEquip, Inc. 211 Wappo Ave., Calistoga,

More information

IQ PROX. Programming Guide. Series. For use with IQ KP* only

IQ PROX. Programming Guide. Series. For use with IQ KP* only IQ PROX Series Programming Guide For use with IQ KP* only Congratulations, you have just purchased the IQ KP*series lockset by Marks USA, the most advanced stand-alone door lock and access control system

More information

First Access Express OPERATOR GUIDE

First Access Express OPERATOR GUIDE First Access Express OPERATOR GUIDE October 2016 Cutting edge simplicity Table of Contents Introduction... 4 PC Requirements... 5 Step 1. Software Installation... 5 Complete Installation Server and Client...

More information

Axxis Biometrics LLC. BioAxxis L113 Fingerprint Door Lock Programming Kit

Axxis Biometrics LLC. BioAxxis L113 Fingerprint Door Lock Programming Kit Axxis Biometrics LLC BioAxxis L113 Fingerprint Door Lock Programming Kit Revision 0.14 Dec 2005 Table of Contents 1. Introduction... 2 Product Overview... 2 Main Features... 2 Packing Lists... 3 2. Operation

More information

Trilogy PL3500 and ETPL Programming Instructions

Trilogy PL3500 and ETPL Programming Instructions 345 Bayview Avenue Amityville, New York 11701 For Sales and Repairs 1-800-ALA-LOCK For Technical Service 1-800-645-9440 ALARM LOCK 2007 Trilogy PL3500 and ETPL Programming Instructions WI1390A 5/07 HID

More information

Trilogy PL3500 and ETPL Programming Instructions

Trilogy PL3500 and ETPL Programming Instructions 345 Bayview Avenue Amityville, New York 11701 For Sales and Repairs 1-800-ALA-LOCK For Technical Service 1-800-645-9440 ALARM LOCK 2005 Trilogy PL3500 and ETPL Programming Instructions WI1390 10/05 HID

More information

4.2. LockView N. Instruction Man

4.2. LockView N. Instruction Man 4.2 Manual n io t c u r t s TC In LockView N ual Instruction Man Table of Contents LockView NTC 4.2 Operator s Manual LockView NTC Instruction Manual LockView NTC Instruction Manual Introduction... 4 Operation...

More information

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions CM-120TX Wireless Digital Keypads Installation Instructions Package Contents - (1) Keypad and faceplate assembly - (1) Foam gasket (CM-120W only) - (2) #6-32 x 1 S/S Phillips screws - (2) #6-32 x 1 Tamperproof

More information

GETTING STARTED. Installing the System 2000 Hardware. Configuring Your System 2000 Hardware. Troubleshooting. Configuring Your System 2000 Network

GETTING STARTED. Installing the System 2000 Hardware. Configuring Your System 2000 Hardware. Troubleshooting. Configuring Your System 2000 Network SYSTEM 2000 GETTING STARTED Installing the System 2000 Hardware Whether you are upgrade an existing System 2, or this is a brand new installation, there will be some hardware installation involved. We

More information

Trilogy DL2800 Programming Instructions

Trilogy DL2800 Programming Instructions 345 Bayview Avenue Amityville, New York 11701 For Sales and Repairs 1-800-ALA-LOCK For Technical Service 1-800-645-9440 Publicly traded on NASDAQ Symbol NSSC ALARM LOCK 2006 Trilogy DL2800 Programming

More information

Index. Disable or Enable Code 06. Definition 02 Factory Default Settings 03 Important Notes 03 Change Master Code 03 Add Code 04

Index. Disable or Enable Code 06. Definition 02 Factory Default Settings 03 Important Notes 03 Change Master Code 03 Add Code 04 Index Definition 02 Factory Default Settings 03 Important Notes 03 Change Master Code 03 Add Code 04 Add a User Code Add Multiple User Codes Add an Office Code Add Multiple office Codes Add a Lockdown

More information

eforce 150 Keyless Entry Owner s manual & User s guide For Model 3090

eforce 150 Keyless Entry Owner s manual & User s guide For Model 3090 eforce 150 Keyless Entry Owner s manual & User s guide For Model 3090 This manual contains important operation, maintenance & warranty information. Save this manual for future reference TABLE OF CONTENTS

More information

PROGRAMMING GUIDE. MARKS USA 365 Bayview Ave., Amityville, NY Fax

PROGRAMMING GUIDE. MARKS USA 365 Bayview Ave., Amityville, NY Fax PROGRAMMING GUIDE MARKS USA 365 Bayview Ave., Amityville, NY 11701 631-225-5400 1-800-526-0233 Fax 631-225-6136 www.marksusa.com Congratulations, you have just purchased the i-qwik LITE Series lockset

More information

212iL Rev. 1.1

212iL Rev. 1.1 212iL 1 International Electronics, Inc. 427 Turnpike Street Canton, Massachusetts 02021 212iL (illuminated Luxury) Keypad Single Unit Keypad- Control Installation Manual Features: 120 User Capability Illuminated

More information

ONYX FINGERPRINT PASSWORD LOCK MANUAL

ONYX FINGERPRINT PASSWORD LOCK MANUAL ONYX FINGERPRINT PASSWORD LOCK MANUAL PREFACE 1. Electronic locks are sensitive and advanced products with fragile micro-chips and hardware. Please be aware that the position and type of environment the

More information

Trilogy DL3200 Programming Instructions

Trilogy DL3200 Programming Instructions 345 Bayview Avenue Amityville, New York 11701 For Sales and Repairs 1-800-ALA-LOCK For Technical Service 1-800-645-9440 Publicly traded on NASDAQ Symbol NSSC ALARM LOCK 2008 Trilogy DL3200 Programming

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS AUDITCON 2 SEIES MODELS 252 & 552 OPEATING INSTUCTIONS Lock Modes A lock is shipped from the factory with default lock setup values and a pre-set PIN for unlocking the lock. This is referred to as Factory

More information

Click Save to return to the main Setup screen.

Click Save to return to the main Setup screen. ON-SITE Setup Guide Thank you for purchasing the ON-SITE. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,

More information

VTC. 200/300 Series. VTC elock controller. VTC elock Instructions. Network VTC elock has three components:

VTC. 200/300 Series. VTC elock controller. VTC elock Instructions. Network VTC elock has three components: 200/300 Series VTC elock Instructions VTC Thank you for purchasing the VTC elock. The information contained in these instructions is intended to serve as a guide so as to allow the elock to be quickly

More information

801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

801 Avenida Acaso, Camarillo, Ca (805) Fax: (805) 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com E70PS Series PC Managed Electronic Lockset E7 Software Installation & Operations

More information

Table of Contents. Introduction 2 1. Intelligent Remote Control 2 2. Charging the Remote Control 3

Table of Contents. Introduction 2 1. Intelligent Remote Control 2 2. Charging the Remote Control 3 Table of Contents Introduction 2 1. Intelligent Remote Control 2 2. Charging the Remote Control 3 Getting Started 6 1. Activating the Remote Control 6 2. Selecting a Device 7 3. Operating a Device 8 4.

More information

SMARTLINC T: Multiple Lock System. AUthorised dealer:

SMARTLINC T: Multiple Lock System. AUthorised dealer: AUthorised dealer: SMARTLINC Multiple Lock System logic module & set-up instructions TIME DELAY Programmable on each lock Period: Delay 1-99 minutes Period: Open 1-19 minutes Counting Delay mode selectable

More information

Trilogy DL4100 / DL4500 Series Programming Instructions WI1194B 10/07

Trilogy DL4100 / DL4500 Series Programming Instructions WI1194B 10/07 345 Bayview Avenue Amityville, New York 11701 For Sales and Repairs 1-800-ALA-LOCK For Technical Service 1-800-645-9440 ALARM LOCK 2007 Trilogy DL4100 / DL4500 Series Programming Instructions WI1194B 10/07

More information

Ceres M7000 Time & Attendance System Installation & Operation Instructions:

Ceres M7000 Time & Attendance System Installation & Operation Instructions: Page1 Ceres M7000 Time & Attendance System Installation & Operation Instructions: Table of Contents I. Minimum requirements:... 2 II. Ceres M7000e Installation (Steps):... 2 III. M7000 ibutton Time Recorder

More information

revolution How does the ibutton work? Full kit including PCB, PICAXE-08M chip and ibutton key. Spare ibutton Key

revolution How does the ibutton work? Full kit including PCB, PICAXE-08M chip and ibutton key. Spare ibutton Key AXE109S LOG020 Full kit including PCB, PICAXE-08M chip and ibutton key. Spare ibutton Key The ibutton is an electronic chip armoured in a 16mm stainless steel can. Because of this unique, durable package,

More information

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual Carefree-Security Heavy Duty Commercial - Industrial Fully Sealed Digital Access Keypad Specially Designed for Gate Operators, Overhead Doors, Specialty Doors & Electric Door Locking Devices SINGLE OR

More information

Entryphone. PinNet 4. Product manual. October 2010 R Granville Road, London SW18 5SD

Entryphone. PinNet 4. Product manual. October 2010 R Granville Road, London SW18 5SD Entryphone PinNet 4 Product manual October 2010 R4.9 www.entryphone.co.uk 23 Granville Road, London SW18 5SD This document covers the installation and use of the Entryphone on-line PinNet door control

More information

Trilogy Double-Sided DL5300 Programming Instructions

Trilogy Double-Sided DL5300 Programming Instructions 345 Bayview Avenue Amityville, New York 11701 For Sales and Repairs 1-800-ALA-LOCK For Technical Service 1-800-645-9440 Publicly traded on NASDAQ Symbol NSSC ALARM LOCK 2008 Trilogy Double-Sided DL5300

More information

39E Electronic Combination Lock SETUP INSTRUCTIONS

39E Electronic Combination Lock SETUP INSTRUCTIONS The ComboGard Pro Lock has three states of operation: Factory Default, Manual Setup, and Active. ComboGard Pro locks are shipped from LA GARD in Factory Default state without Users or features enabled.

More information

XP-KIT. Programming & Operations. Programming Starter Kit for Aiphone -XP Series Proximity Reader Stations

XP-KIT. Programming & Operations. Programming Starter Kit for Aiphone -XP Series Proximity Reader Stations 9800 XP-KIT Programming Starter Kit for Aiphone -XP Series Proximity Reader Stations Programming & Operations Manual KIT CONTENTS: Programming Keypad Programming Master Card Pack 0 Blank Proximity Cards

More information

Trilogy PDL3000 & PDL3500 Programming Instructions

Trilogy PDL3000 & PDL3500 Programming Instructions 345 Bayview Avenue Amityville, New York 11701 For Sales and Repairs 1-800-ALA-LOCK For Technical Service 1-800-645-9440 Publicly traded on NASDAQ Symbol NSSC ALARM LOCK 2008 Trilogy PDL3000 & PDL3500 Programming

More information

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Stand alone CR-R885-SB Installation and Operating Instructions V1.1 TABLE OF CONTENTS Installation... 2 Mounting and Wiring... 2 Mounting

More information

Living. Keyfree Connected Smart Lock Manual. smart. The smarter way to protect your home

Living. Keyfree Connected Smart Lock Manual. smart. The smarter way to protect your home smart Living Keyfree Connected Smart Lock Manual Please read the intructions before fitting and using the Keyfree Connected lock. The functions and design of this product can be changed without prior notice

More information

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you 1 of 6 START HERE 1 Carefully unpack box. 2 Make sure you have everything shown here. 3 Unlock and remove front panel of keypad unit, then using carriage bolts and hex nuts, attach unit to pedestal as

More information

Guangdong Be-tech Security Systems Limited. BIS Hotel 5.7 Manual Instruction. Version 2013 Page1 total 93

Guangdong Be-tech Security Systems Limited. BIS Hotel 5.7 Manual Instruction. Version 2013 Page1 total 93 BIS Hotel 5.7 Manual Instruction Version 2013 Page1 total 93 Content Guangdong Be-tech Security Systems Limited 1. System Overview... 5 1.1. System components... 5 1.1.1. The door locks... 5 1.1.2. General

More information

GSM GATE INTERCOM WITH KEYPAD Control your gate with your mobile phone

GSM GATE INTERCOM WITH KEYPAD Control your gate with your mobile phone GSM GATE INTERCOM WITH KEYPAD Control your gate with your mobile phone www.gsm-activate.co.uk Page 1 Product Information The GSM Gate Intercom incorporates a professional industrial grade GSM engine that

More information

Terminology erl Lock Device erl Lock Device erl Remote Access Controller erl Remote Access Controller erl Lock Device ATR-11 Audit Trail Reader WHO

Terminology erl Lock Device erl Lock Device erl Remote Access Controller erl Remote Access Controller erl Lock Device ATR-11 Audit Trail Reader WHO Terminology erl Lock Device The erl Lock Device is the lock installed on the door of your rental property. It is a self contained, electronically controlled, battery powered, single door access control

More information

HN1000/HN2000 Product Manual

HN1000/HN2000 Product Manual HN1000/HN2000 Product Manual TABLE OF CONTENTS 1.0 Introduction...1 2.0 Mounting the HN1000/HN2000... 2 3.0 Setting Up Your Optional upunch Account... 4 3.1 Creating Your Account...4 3.2 Adding Departments

More information

PAC1 Door Access Controller

PAC1 Door Access Controller PAC1 Door Access Controller Series 1 TABLE OF CONTENTS i PAGE Introduction...1 Features...1 Specifications...2 Terminal Descriptions...3 Programmable Features Description...5 Automatic Relock Function...5

More information

Model P4470 Save A Watt Operation Manual

Model P4470 Save A Watt Operation Manual Model P4470 Save A Watt Operation Manual Thank you for purchasing the P4470 Save A Watt. This operating manual will provide an overview of the product, safety instructions, a quick guide to operation,

More information

PAC1 Door Access Controller

PAC1 Door Access Controller PAC1 Door Access Controller Series 1 100% Designed and Manufactured by: NIDAC SECURITY PTY. LTD. 2 CROMWELL STREET BURWOOD, VICTORIA Tel: (03) 9808 6244 AUSTRALIA 3125 Fax: (03) 9808 9335 Revision 1.1

More information

ADVANCED USER S GUIDE

ADVANCED USER S GUIDE ADVANCED USER S GUIDE MFC-7360 MFC-7360N MFC-7460DN MFC-7470D MFC-7860DW Not all models are available in all countries. Version A SAF/GLF User's Guides and where do I find it? Which manual? What's in it?

More information

CROWN JEWEL SOFTWARE FOR WINDOWS SOFTWARE REV.

CROWN JEWEL SOFTWARE FOR WINDOWS SOFTWARE REV. CJWin CROWN JEWEL SOFTWARE FOR WINDOWS SOFTWARE REV. 2.20 Crown Jewel (with Camera) Crown Jewel (Brass Enclosure) User s Guide TABLE OF CONTENTS Getting Started System Requirements.................................3

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

Trilogy PDK3000 Series Programming Instructions ALARM LOCK 2005 WI 1120D 5/05

Trilogy PDK3000 Series Programming Instructions ALARM LOCK 2005 WI 1120D 5/05 345 Bayview Avenue Amityville, New York 11701 For Sales and Repairs 1-800-ALA-LOCK For Technical Service 1-800-645-9440 Trilogy PDK3000 Series Programming Instructions ALARM LOCK 2005 WI 1120D 5/05 PDK3000

More information

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

INSTALLATION INSTRUCTIONS 920 EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920 EntryCheck TM The EntryCheck 920 Indoor/Outdoor Keypad is a surface-mount

More information

Chapter 3. Using the System CHANGING CHANNELS USING THE MENUS OPENING THE MENUS CLOSING THE MENUS MENU OPTIONS

Chapter 3. Using the System CHANGING CHANNELS USING THE MENUS OPENING THE MENUS CLOSING THE MENUS MENU OPTIONS CHANGING CHANNELS There are three basic ways to change channels while watching a program: Press the remote control UP or DOWN ARROW button to get to the desired channel. Use the remote control number pad

More information

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM 80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount

More information

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ ) e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ 18990-04) Table of Contents Introduction... 1 e-fob Operation and

More information

PAC2 Dual Door Access Controller

PAC2 Dual Door Access Controller PAC2 Dual Door Access Controller Series 2 IMPORTANT DIFFERENCES FROM SERIES 1 1. All programming can only be done through devices attached to DTA1. 2. A PACDL data logger revision 4.0 or higher attached

More information

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

INSTALLATION INSTRUCTIONS 920P EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920P EntryCheck TM The EntryCheck 920P Indoor/Outdoor Keypad is a surface-mount

More information

Stand-Alone Data Chip System

Stand-Alone Data Chip System Stand-Alone Data Chip System OVERVIEW This Data Chip System supports up to 17 users and each user can be added or deleted in a matter of seconds. This System can be used in a variety of Security and Access

More information

Configuring Cisco Access Policies

Configuring Cisco Access Policies CHAPTER 11 This chapter describes how to create the Cisco Access Policies assigned to badge holders that define which doors they can access, and the dates and times of that access. Once created, access

More information

Lockbox Getting Started Guide

Lockbox Getting Started Guide NXT Series Lockbox Getting Started Guide by SentriLock LLC Published by: SentriLock, LLC Copyright 2003-2012 by SentriLock, LLC All rights reserved. You may not reproduce or transmit any part of this document

More information

200/300 Series. CompX cabinet elock Instructions. elock controller. Network cabinet elock has three components:

200/300 Series. CompX cabinet elock Instructions. elock controller. Network cabinet elock has three components: 200/300 Series CompX cabinet elock Instructions Thank you for purchasing the CompX elock. The information contained in these instructions is intended to serve as a guide so as to allow the elock to be

More information

Access control panel U-Prox IC E (Elevator control)

Access control panel U-Prox IC E (Elevator control) 1.003 Access control panel U-Prox IC E (Elevator control) Installation and programming manual About this document http://u-prox.com This manual covers installation, adjustment and use of U-Prox IC E (hereinafter

More information

Apricorn Aegis Secure Key

Apricorn Aegis Secure Key 1 2 3 4 5 6 7 8 9 0 Table of Contents Introduction... LED Indicators... Unlocking the Aegis Secure Key... Changing your PIN code... Resetting your Aegis Secure Key... Setup new PIN after resetting Aegis

More information

DS-K2600 Series Access Controller. Quick Setup Guide. Ness V1.0

DS-K2600 Series Access Controller. Quick Setup Guide. Ness V1.0 DS-K2600 Series Access Controller Quick Setup Guide Ness V1.0 This is a Quick Setup Guide for Ness Version of Hikvision DS-K2604 4 Door Access Controllers. For full details refer Ness Full User Manual

More information

Keypad Programming Instructions For the Access 800 Series Locks

Keypad Programming Instructions For the Access 800 Series Locks FM226 3/05 (617417440) Keypad Programming Instructions For the Access 800 Series Locks 1 2 3 4 5 6 7 8 9 * 0 # 1 2 3 4 5 6 7 8 9 * 0 # CYLINDRICAL 1 2 3 4 5 6 7 8 9 * 0 # EXIT MORTISE For programming assistance,

More information

Access 800TM. Keypad Programming Instructions. Locks CYLINDRICAL EXIT MORTISE

Access 800TM. Keypad Programming Instructions. Locks CYLINDRICAL EXIT MORTISE Access 800TM 1 2 3 4 5 6 7 8 9 * 0 # 1 2 3 4 5 6 7 8 9 * 0 # CYLINDRICAL 1 2 3 4 5 6 7 8 9 * 0 # EXIT MORTISE TOC 1 2 3 4 5 6 7 Table of Contents Overview.... 2 General Programming.... 3 Individual Door

More information

User Manual. Smart Lock. Please read this manual before operating your Smart Lock, and keep it for further reference. 40

User Manual. Smart Lock. Please read this manual before operating your Smart Lock, and keep it for further reference. 40 User Manual Smart Lock Please read this manual before operating your Smart Lock, and keep it for further reference. 40 I. Introduction Thank you for choosing the AKASO Smart Lock. The new Smart Lock uses

More information

GlucoManager TM Software. User s Guide

GlucoManager TM Software. User s Guide GlucoManager TM Software User s Guide 1 Table of Contents Preface... 6 Software Overview... 6 Intended Use... 7 Purpose and Scope... 7 Computer Requirements... 8 Technical Support... 9 1. Introduction...

More information

Keyless Entry 5. MANUALLY PROGRAMMING THE SNAP-ON LEVEL 5 GEN 4 LOCK Instruction Manual

Keyless Entry 5. MANUALLY PROGRAMMING THE SNAP-ON LEVEL 5 GEN 4 LOCK Instruction Manual Keyless Entry 5 MANUALLY PROGRAMMING THE SNAP-ON LEVEL 5 GEN 4 LOCK Instruction Manual TABLE OF CONTENTS Setting up the Snap-on Level 5 Gen4 Lock Manual Setting up the Snap-on Level 5 Gen4 Lock... 3 Basic

More information

PROXIMITY Encoding System

PROXIMITY Encoding System PROXIMITY Encoding System ins-206 Date code: 251103 Contents 2 Contents Setting up the system...4 Introduction...4 What s in the box...5 Installing the system...5 Initialising the program...6 Initialising

More information

Electra Elite and InfoSet are registered trademarks of NEC America, Inc.

Electra Elite and InfoSet are registered trademarks of NEC America, Inc. reserves the right to change the specifications, functions, or features, at any time, without notice. has prepared this document for the use by its employees and customers. The information contained herein

More information

NetworX Series NX-1710E Single Door Control. Installation and Startup Manual

NetworX Series NX-1710E Single Door Control. Installation and Startup Manual NetworX Series NX-1710E Single Door Control Installation and Startup Manual 2005 GE Security All rights reserved. NetworX is a trademark of the GE companies. Printed in the USA. These instructions do not

More information

Revision Date: 02 Mar 2018

Revision Date: 02 Mar 2018 KAS Bluetooth Locks HOMES AIRBNB OFFICES SHARED SPACE Revision Date: 02 Mar 2018 COPYRIGHT: Information in this document is subject to change without further notice. No part of this document can be reproduced

More information

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

Wiring Guide EP.NMINI. Version 1.02 Last Updated: Wiring Guide EP.NMINI Version 1.02 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual There are currently 2 version of EntryPass

More information

Installation and Operating Instructions Audit Trail Software for 6126/6127/6128/6129 Series

Installation and Operating Instructions Audit Trail Software for 6126/6127/6128/6129 Series Installation and Operating Instructions Audit Trail Software for 6126/6127/6128/6129 Series General Notes These instructions are for installing S&G Audit Software (and all associated software components)

More information

Setup Instructions. LA GARD ComboGard Pro 39E Electronic Lock

Setup Instructions. LA GARD ComboGard Pro 39E Electronic Lock Setup Instructions LA GARD ComboGard Pro 39E Electronic Lock P/N 731.018 Rev I - 05/2018 ComboGard Pro locks can either be configured using the ComboGard Pro Setup software or through a series of keypad

More information

Model FP700 Owner s Instructions

Model FP700 Owner s Instructions The benefits of owning a Freedom Advantage Thermostat Large easy to read backlit display Selectable programming modes: 5-2, 5-1-1 or 7 day Manufactured by the makers of ACCUSTAT controls ServiceWatch for

More information

Wireless Trilogy DL6500 & ETDLN Programming Instructions

Wireless Trilogy DL6500 & ETDLN Programming Instructions 345 Bayview Avenue Amityville, New York 11701 For Sales and Repairs 1-800-ALA-LOCK For Technical Service 1-800-645-9440 Publicly traded on NASDAQ Symbol NSSC ALARM LOCK 2011 Wireless Trilogy DL6500 & ETDLN

More information

Pronto. User Guide. User Guide

Pronto. User Guide. User Guide Pronto EN 1 Pronto Copyright 2005 Royal Philips Electronics, Interleuvenlaan 72-74, 3000 Leuven (Belgium) Remark: All rights are reserved. Reproduction in whole or in part is prohibited without prior consent

More information

CLIQ Web Manager. User Manual. The global leader in door opening solutions V 6.1

CLIQ Web Manager. User Manual. The global leader in door opening solutions V 6.1 CLIQ Web Manager User Manual V 6.1 The global leader in door opening solutions Program version: 6.1 Document number: ST-003478 Date published: 2016-03-31 Language: en-gb Table of contents 1 Overview...9

More information

Security Access Manager (SAM ) System. Operations Manual

Security Access Manager (SAM ) System. Operations Manual FPO Cover Art to be supplied by SAFLOK Security Access Manager (SAM ) System Version 1.0 Operations Manual Project Description The SAM System Operations Manual was created to provide end users (apartment

More information

Trilogy Double-Sided PDL5300 Programming Instructions

Trilogy Double-Sided PDL5300 Programming Instructions 345 Bayview Avenue Amityville, New York 11701 For Sales and Repairs 1-800-ALA-LOCK For Technical Service 1-800-645-9440 Publicly traded on NASDAQ Symbol NSSC ALARM LOCK 2008 Trilogy Double-Sided PDL5300

More information

ProntoPro Intelligent Remote Control. User Guide

ProntoPro Intelligent Remote Control. User Guide ProntoPro Intelligent Remote Control User Guide Table of Content Taking a First Look... 3 Intelligent Remote Control... 3 Before You Start... 5 Getting Started... 7 Activating the Remote Control... 7 Defining

More information

BioPointe. User's Manual

BioPointe. User's Manual BioPointe User's Manual Getting to know the BioPointe Notices: Information in this document is subject to change without notice. NO WARRANTY OF ANY KIND IS MADE WITH REGARD TO THIS MATERIAL INCLUDING,

More information

Table of Contents.

Table of Contents. Table of Contents http://www.advancedactuators.com 1. Items Included with the ThumbLock PCMU:... 2 2. IMPORTANT NOTE:... 2 3. Supported Operating Systems:... 2 Section 1 Installing the ThumbLock PCMU Software...

More information

Table of Contents. Taking a First Look 2 Intelligent Remote Control 2 Before You Start 4

Table of Contents. Taking a First Look 2 Intelligent Remote Control 2 Before You Start 4 Table of Contents Taking a First Look 2 Intelligent Remote Control 2 Before You Start 4 Getting Started 6 Activating the Remote Control 6 Defining the Brands of Your Devices 7 Working with the Home Panel

More information

Total Recall for the MultiLevel Capture System Operation Guide

Total Recall for the MultiLevel Capture System Operation Guide Total Recall for the MultiLevel Capture System Operation Guide European Office: 25 Putney Close Brandon Suffolk IP27 OPA United Kingdom Tel: +44 (0) 1842 814 814 Fax: +44 (0) 1842 813 802 North American

More information

PROGRAMMING AND USE INSTRUCTIONS FOR THE OVATION SYSTEM

PROGRAMMING AND USE INSTRUCTIONS FOR THE OVATION SYSTEM Doc. 6001012 Rev B PROGRAMMING AND USE INSTRUCTIONS FOR THE OVATION SYSTEM ALPHA COMMUNICATIONS 42 Central Drive Farmingdale NY 11735-1202 Phone: 631-777-5500 - Fax: 631-777-5599 IMPORTANT NOTICE If the

More information

QUICK START USER GUIDE. Data Logger Model L452

QUICK START USER GUIDE. Data Logger Model L452 QUICK START USER GUIDE Data Logger Model L452 Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments traceable

More information

1 / Spectrum Brands, Inc.

1 / Spectrum Brands, Inc. 1 / 11 2016 Spectrum Brands, Inc. 1 Prepare the door and check dimensions If drilling a new door, use the supplied template and the complete door drilling instructions available at www.kwikset.com/doorprep.

More information

BUT2 7day 11/4/07 11:07 PM Page 1. Introduction

BUT2 7day 11/4/07 11:07 PM Page 1. Introduction BUT2 7day 11/4/07 11:07 PM Page 1 Introduction This booklet will give you easy to follow instructions to allow you to set your BUT2 Timeswitch to the 7 Day, (different times every day) program. Contents

More information

ATTENTION. Custom Dynamics CCM-6 Bluetooth Remote Installation Instructions. Package Contents: - Bluetooth Remote Module (1) - Remote Key Fob (2)

ATTENTION. Custom Dynamics CCM-6 Bluetooth Remote Installation Instructions. Package Contents: - Bluetooth Remote Module (1) - Remote Key Fob (2) Custom Dynamics CCM-6 Bluetooth Remote Installation Instructions We thank you for purchasing the Custom Dynamics CCM-6 Bluetooth Remote Module. Our products utilize the latest technology and high quality

More information

KEYPAD MODEL USER MANUAL

KEYPAD MODEL USER MANUAL KEYPAD MODEL USER MANUAL Contents SecureDrive Overview 3 Safety Information 3 SecureDrive Features 4 PINs and Procedures 5 User Mode 5 User PINs 5 Unlocking the Drive in User Mode 6 Changing the User PIN

More information

AK-21. Digital Keyless Entry System. Installation and Programming Instructions

AK-21. Digital Keyless Entry System. Installation and Programming Instructions AK-2 Digital Keyless Entry System Installation and Programming Instructions (760) 8-7000 USA & Canada (800) 2-587 & (800) 92-02 Toll Free FAX (800) 68-0 www.linearcorp.com CONTENTS COMPONENT LOCATIONS.......................................

More information

DL1300. Programming Instructions. DL Trilogy Series Stand-Alone Access Control Systems OI311 7/06 ALARM LOCK 2006 DL1300

DL1300. Programming Instructions. DL Trilogy Series Stand-Alone Access Control Systems OI311 7/06 ALARM LOCK 2006 DL1300 345 Bayview Avenue Amityville, New York 11701 For Sales and Repairs 1-800-ALA-LOCK For Technical Service 1-800-645-9440 ALARM LOCK 2006 DL1300 Programming Instructions Publicly traded on NASDAQ Symbol

More information

Table of Contents.

Table of Contents. Table of Contents http://www.bioaxxis.com 1. Items Included with the BioAxxis ThumbLock PCMU:...2 2. IMPORTANT NOTE:...2 3. Supported Operating Systems:...2 Section 1 Installing the BioAxxis ThumbLock

More information

960P and 1080P HD Video Security DVR System User Manual

960P and 1080P HD Video Security DVR System User Manual 960P and 1080P HD Video Security DVR System User Manual www.tigersecu.com Copyright 2017 TIGERSECU, Inc Contents Contents... 1 Important Information...3 Installation Guide....4 Chapter 1. Start-up Wizard...6

More information

LCD62. Keypad. User Manual

LCD62. Keypad. User Manual LCD62 Keypad User Manual Disclaimer: While every effort has been made to ensure that the information in this manual is accurate and complete, no liability can be accepted for any errors or omissions The

More information