Hardware User s Guide
|
|
- Everett Houston
- 5 years ago
- Views:
Transcription
1 Hardware User s Guide 6 QuickPanel View Intermediate, color STN & monochrome, flat bezel IC754VGI06STD IC754VHI06STD IC754VGI06MTD IC754VHI06MTD January 2007 GFK-2326A
2
3 All rights reserved. No part of this publication may be reproduced in any form or by any electronic or mechanical means, including photocopying and recording, without permission in writing from GE Fanuc Automation. Disclaimer of Warranties and Liability The information contained in this manual is believed to be accurate and reliable. However, GE Fanuc Automation assumes no responsibilities for any errors, omissions or inaccuracies whatsoever. Without limiting the forgoing, GE Fanuc Automation disclaims any and all warranties, expressed or implied, including the warranty of merchantability and fitness for a particular purpose, with respect to the information contained in this manual and the equipment or software described herein. The entire risk as to the quality and performance of such information, equipment and software, is upon the buyer or user. GE Fanuc Automation shall not be liable for any damages, including special or consequential damages, arising out of the use of such information, equipment and software, even if GE Fanuc Automation has been advised in advance of the possibility of such damages. The use of the information contained in the manual and the software described herein is subject to GE Fanuc Automation s standard license agreement, which must be executed by the buyer or user before the use of such information, equipment or software. Notices GE Fanuc Automation reserves the right to make improvements to the products described in this publication at any time and without notice GE Fanuc Automation. All rights reserved. QuickPanel View is a trademark of GE Fanuc Automation, in the United States and other countries. Any other trademarks referenced herein are the property of their respective owners and used solely for purposes of identifying compatibility with the products of GE Fanuc Automation. The 6 QuickPanel View has been tested and found to meet or exceed the requirements of U.S. (47 CFR 15), Canadian (ICES-003), Australian (AS/NZS 3548) and European (EN55022) regulations for Class A digital devices when installed in accordance with guidelines noted in this manual. Microsoft requires the following notes be published according to their additional licensing provisions: Users are advised that a maximum of ten (10) computers or other electronic devices may simultaneously connect to, access and use services of the Microsoft Windows CE Operating system on the QuickPanel View solely for remote access (including connection sharing) The ten connection maximum includes any indirect connections made through multiplexing, or other software or hardware which pools or aggregates connections. Note that the QuickPanel View does not provide any server functionality utilizing Remote Desktop Protocol (RDP) to remotely connected client computers or devices. However, it does support connectivity to a remote Microsoft Terminal Services server. The server providing these services must meet these restrictions and other Microsoft licensing requirements as applicable. Notice Regarding Video Standards This product is licensed under one or more video patent portfolio licenses such as and without limitation VC-1 and MPEG4 Part 2 Visual for the personal and non-commercial use of a
4 consumer to: (i) Encode video in compliance with the standards licensed under such patent portfolio licenses and/or (ii) Decode video that was encoded by a consumer engaged in a personal and non-commercial activity and/or was obtained from a video provider licensed to provide video under such patent portfolio licenses. Such license extends to this product only and only to the extent of other notices which may be included in this document. The license does not extend to any other product regardless of whether such product is included with this licensed product in a single article. No license is granted or shall be implied for any other use. Additional information may be obtained from MPEG LA, L.L.C. See The FCC requires the following note to be published according to FCC guidelines: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Any changes or modifications to the product or installation that are not expressly approved by GE Fanuc Automation could void the user's authority to operate the equipment under FCC rules. Industry Canada requires the following note to be published: This Class A digital apparatus complies with Canadian ICES-003. The following statements are required to appear for Class I Div 2 Hazardous Locations. 1. WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1, DIV WARNING - EXPLOSION HAZARD - WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING MODULES. 3. WARNING - EXPLOSION HAZARD - DO NOT CONNECT OR DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR AREA IS KNOWN TO BE NON-HARZARDOUS. Power, input and output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods, Article 501 4(b) of the National Electric Code, NFPA 70 and in accordance with the authority having jurisdiction. For a complete list of agency qualifications, please refer to Appendix A1. We want to hear from you. If you have any comments, questions, or suggestions about our documentation, send them to the following address: doc@gefanuc.com.
5 Contents 1 Welcome 1 Getting Started Basic Setup Unit Runtime Setup Startup Shutdown Panel Cutout Technical Support Overview 9 QuickPanel View Hardware Layout Diagram Block Diagram QuickPanel View Software Windows CE.NET Working with Windows CE Pocket Internet Explorer Backup Reboot Storage Manager System Information Copy Project to Flash Card Emulate PPC HTTP File Transfer Utility FTP Server Detailed Operation 25 Touch Screen Display Touch Screen Keyboard Soft Input Panel Communication Port COM1- Serial Recommended Cabling for TIA/EIA422 or TIA/EIA Working with the COM port CF Port GFK-2326A 6" QuickPanel View v
6 Contents Ethernet Expansion Bus DIP Switches Memory Flash Memory SRAM Memory DRAM Memory Boot Loader ROM Memory Expansion Slot Other Subsystems Power Management Battery Backup Real-time Clock Configuring SNTP A1 Design Specifications 59 Physical DC Power Display Front Panel Touch Screen CPU Memory Memory Expansion Slot Expansion Ports Communication Port Environmental Battery Calendar/Clock Agency Qualifications A2 Troubleshooting 65 Power up Pocket Internet Explorer Physical Unit Index 67 vi 6" QuickPanel View GFK-2326A
7
8 Contents viii 6" QuickPanel View GFK-2326A
9 1 Welcome Congratulations on your purchase of a QuickPanel View, the most advanced compact HMI available. The QuickPanel View is available in different configurations to suit your requirements. Equally at home in a networked environment or as a stand-alone unit, the QuickPanel View is the ideal solution for factory floor HMI. Powered by Microsoft Windows CE.NET TM, today s embedded operating system of choice, the QuickPanel View provides a fast track for application program development. The commonality with other versions of Windows simplifies porting your existing program code. Another benefit of Windows CE is the familiarity of the user interface, shortening the learning curve for operators and developers alike. The availability of third-party application software makes this operating system even more attractive. The 6" QuickPanel View is an all-in-one microcomputer designed for maximum flexibility. The design, based on an advanced Intel microprocessor, brings together a high-resolution operator interface with a variety of I/O options. With many standard ports and expansion busses from which to choose, you can connect to most industrial equipment. The QuickPanel View is equipped with several memory types to satisfy even the most demanding applications. A 32 MB section of DRAM is split between the operating system, an object store, and application memory. A 32 MB section of non-volatile FLASH memory, functioning as a virtual hard drive, is divided between the operating system and persistent storage for application programs. The retentive memory consists of 512 KB of battery-backed SRAM for data storage, ensuring your valuable data will never be lost, even during a power failure. The many features of the QuickPanel View make it an obvious choice for a world of applications. Your smart choice will provide reliable operation for years to come. GFK-2326A 6" QuickPanel View 1
10 1 Welcome Getting Started GETTING STARTED Basic Setup Your 6" QuickPanel View is shipped ready for use after a few configuration steps. To power up all you need to do is connect a DC power supply via the supplied quick-connect plug. Depending on your application, you may also want to connect and configure optional input devices (see page 31), communications ports (see page 36) and expansion adapters (see page 47). Optional Ethernet Connection Optional Expansion I/O Power Supply Caution - Electrical Shock Hazard: To avoid personal injury or damage to equipment, ensure that the DC supply is disconnected from power and that the leads are not energized before attaching them to the unit's power supply plug. To connect a DC power supply 1. Using the three screw terminals shown in the following diagram, attach a 24VDC, 24W power supply to the plug supplied with the QuickPanel View. See the DC Power section starting on page 59 for power supply and conductor specifications. 2. Insert the plug into the power supply socket and securely tighten the attaching screws. Bottom Power Supply Plug Power Supply Socket + 24 VDC 0V Frame Ground Insert leads in screw end 2 6" QuickPanel View GFK-2326A
11 Welcome Getting Started Note: The torque range for the attaching screws is 4-6 inch/lbs. Unit Runtime Setup To download an application to a QuickPanel View, you must set up a data link between it and your development workstation. For more information, see Ethernet (page 36) and look up Downloading a Machine Edition Project in Proficy Machine Edition online help. Startup When you first start up the QuickPanel View, a few configuration steps are necessary. To start the QuickPanel View 1. Apply AC power to the 24VDC supply. Once power is applied, the QuickPanel View begins initializing. The first thing to appear on the display is the splash screen. 2. To skip running any programs included in the StartUp folder, tap Don t run StartUp programs. The splash screen disappears automatically after about 5 seconds. The Windows CE desktop then becomes visible. 3. Tap Start, point to Settings, then tap Control Panel. 4. In the Control Panel, double-tap Display to configure the LCD display (see page 26). 5. In the Control Panel, double-tap Stylus to configure the touch screen (see page 28). 6. In the Control Panel, double-tap Date and Time to configure the system clock (see page 55). 7. In the Control Panel, double-tap System to configure a network machine name (see page 45). Many applications, including Proficy Historian, require a unique machine name. It is recommended procedure to set a unique network name for the QuickPanel View to avoid future conflicts. 8. In the Control Panel, double-tap Network and Dial-up Connections to configure network settings (see page 44). GFK-2326A 6" QuickPanel View 3
12 1 Welcome Getting Started 9. On the desktop, double-tap Backup to save any new settings through a power cycle (see page 16). Shutdown There are no specific dangers associated with a power failure or other unplanned shutdown of the QuickPanel View. In general, programs are retained in FLASH memory and user data can be retained in battery-backed SRAM. However, some operating system settings are retained only with user intervention (noted throughout this manual), so in order to carry out a graceful shutdown of the QuickPanel View, we recommend you perform the following procedure. To shut down the QuickPanel View 1. Quit any programs that are running and wait for all file operations to complete. 2. To save changes to operating system settings (e.g., contrast or touch screen sensitivity), run Backup (see page 16). 3. Run Reboot (see page 17). When the Windows CE desktop reappears, remove AC power from the 24VDC supply. Panel Cutout For convenience and versatility, this version of the QuickPanel View can be mounted in cutouts of two different specifications. Refer to the appropriate section that follows. Small Cutout Dimensions. Panel Cutout Height: 4.86 (+0.103, -0 ) (123.5mm [+2.6mm, -0mm]) mm Width 6.14 (+0.55, -0 ) (156mm, [+14mm, -0mm]) Depth 2.76 (70mm) Bezel Dimensions Height: 6.68 (169.6mm) Width: 8.5 in. (215.9mm) mm Panel thickness range: to (1.6mm to 5mm) The unit will not fit through the small cutout with a CF card inserted in the port, with any cables connected, or with the power supply plug inserted in the socket. 4 6" QuickPanel View GFK-2326A
13 Welcome Getting Started To secure the QuickPanel View to a panel with the small cutout, use the four included mounting clips, which hook into the openings located on the top and bottom of the housing as shown in the following illustration. Inner gasket channel Bracket (x 4) To mount the unit in a panel with small cutout dimensions 1. Separate the small cutout gasket from the supplied gasket sheet (the small cutout gasket is nested within the larger one, and has two notches on each long side). Avoiding damage to the gasket, carefully remove the covering over its adhesive backing, and then apply the gasket with its adhesive surface toward the inner gasket channel (see the illustration above). 2. Verify that the gasket is properly seated in the gasket channel, then insert the unit into the panel cutout (without a CF card in the CF port). 3. Insert the hook of each mounting bracket in the housing openings. 4. Tighten the screws to inch/lbs ( Nm). GFK-2326A 6" QuickPanel View 5
14 1 Welcome Getting Started Large Cutout Dimensions Panel Cutout Height: 6.12 (+/ ) (155.45mm [+/- 0.51mm]) mm Width 7.95 (+/ ) (200mm, [+/- 0.51mm]) Depth 3.35 (85.1mm) Bezel Dimensions Height: 6.68 (169.6mm) Width: 8.5 in. (215.9mm) mm Panel thickness range: to (1.6mm to 5mm) To secure the QuickPanel View to a panel with the large cutout, use the four included mounting clips, which hook into the openings located on the top and bottom of the housing, as well as the four included clip extensions, which slide over the inner portion of the bezel as shown in the following illustration. Outer gasket channel Clip (x 4) Extension (x 4) 6 6" QuickPanel View GFK-2326A
15 Welcome Getting Started To mount the unit in a panel with large cutout dimensions 1. Separate the large cutout gasket from the supplied gasket sheet (the large cutout gasket surrounds the outside of the sheet). Avoiding damage to the gasket, carefully remove the covering over its adhesive backing, and then apply the gasket with its adhesive surface toward the outer gasket channel (see the illustration above). 2. Verify that the gasket is properly seated in the gasket channel, then insert the unit into the panel cutout (without a CF card in the CF port, to avoid damage to the card). 3. Slide the clip extensions over the inner portion of the bezel, at the location of the mounting clip holes in the housing. 4. Insert the hook of each mounting clip in the housing openings. 5. Tighten the screws to inch/lbs ( Nm). The mounting clips hold the unit in place by tension alone. No drilling is required. Notes: For compliance to NEMA 4, 4x, and 12 qualification, the unit must be mounted in a comparably NEMA rated (IP56 equivalent) panel or enclosure. For compliance to ATEX agency qualification, the unit must be mounted in an IP66 panel or enclosure. To avoid gasket degradation, limit repeated insertions or removals of the unit and retightening of the mounting clips. For full protection, always use a fresh gasket. Replacement gaskets may be ordered using part number IC754ACC06GASE. For adequate ventilation, allow at least 3 inches of space between adjacent equipment and all sides of the QuickPanel. Ensure that specified conditions of temperature and humidity are not exceeded. In outdoor applications, direct sun exposure may impose increased thermal loads on the QuickPanel leading to excessive temperature rises. Cabinet design and orientation must be carefully considered to avoid exceeding the operational temperature limits. These considerations could include shading for the QuickPanel and its cabinet with awnings or other solar opaque materials, avoiding a due East or West facing of the cabinet, ventilation or active cooling of the cabinet, or other methods. GFK-2326A 6" QuickPanel View 7
16 1 Welcome Technical Support TECHNICAL SUPPORT If you are located in North America and have technical problems that cannot be resolved with the information in this guide, please contact us by telephone, fax, or ; or visit one of the links on our website: Telephone: GE-FANUC ( ) Fax: (780) In South America: Telephone: +58 (261) Fax: +58 (261) In Europe, the Middle East, and Africa: Telephone: GE-FANUC ( ) In Asia Pacific: Telephone: (China customers) (Japan customers) (India and remaining Asia customers) Web: (to locate the Technical Advisor page and a listing of supported devices (CF cards, etc.) click on the Operator Interface Product Family link or choose QuickPanel View from the Product list). Comments about our manuals or help: doc@gefanuc.com 8 6" QuickPanel View GFK-2326A
17 2 Overview This chapter provides introductory information on the 6" QuickPanel View hardware and software with descriptive procedures for completing some of the most common tasks you will encounter. In this chapter: QUICKPANEL VIEW HARDWARE Layout Diagram 10 Block Diagram 12 QUICKPANEL VIEW SOFTWARE Windows CE.NET 13 Working with Windows CE 13 To place a program in the Start menu 14 Pocket Internet Explorer 14 To configure a dial-up connection 14 To configure a Proxy server 15 Backup 16 To run the Backup program 16 Reboot 17 To reboot the system 17 Storage Manager 18 System Information 18 To run the System Information program 18 Copy Project to Flash Card 18 To copy a Machine Edition project onto a CF card 19 To update a Machine Edition project 19 Emulate PPC 19 To use Emulate PPC during an ActiveSync session 19 HTTP File Transfer Utility 19 To use the HTTP utility 20 FTP Server 21 To install a certificate 23 GFK-2326A 6" QuickPanel View 9
18 2 Overview QuickPanel View Hardware QUICKPANEL VIEW HARDWARE Layout Diagram In addition to the primary touch screen interface, the 6" QuickPanel View supports a variety of communication ports including an expansion bus to allow great flexibility in application. The back of the QuickPanel opens allowing access to the expansion bus connector, memory expansion connector, DIP switches and battery. The following diagram shows the physical layout of the QuickPanel View and the locations of ports and connections. Caution: Remove power from the QuickPanel View before opening the back. Working on a live unit may result in damage to equipment and injury to personnel. Always use anti-static precautions (i.e. grounded wrist strap) when accessing the interior of the unit. Do not allow conductive material, liquid or solid, to contact the electronics of the QuickPanel. The left LED below the display is green when power is applied and amber if the backlight fails; 1 the right LED is tricolor (green, red, or amber) and programmable. 1 Backlight is not field replaceable. 10 6" QuickPanel View GFK-2326A
19 Overview QuickPanel View Hardware Front Right Side Touch screen LCD display. See page 26 CF Port. See page 42 LEDs Bottom Power supply socket. See page 2 Hinged access cover for expansion (see page 47), and battery (see page 54) Not to scale Ethernet port. See page 43 RS232/485 port (COM1). See page 36 GFK-2326A 6" QuickPanel View 11
20 2 Overview QuickPanel View Hardware Block Diagram The 6" QuickPanel View is based on the Intel XScale PXA255 microprocessor, and employs large-scale integration to provide high performance with a small footprint. The following block diagram illustrates the major functional areas of the QuickPanel View and the interfaces between them. 12 6" QuickPanel View GFK-2326A
21 Overview QuickPanel View Software QUICKPANEL VIEW SOFTWARE Windows CE.NET Microsoft Windows CE.NET is the operating system for the QuickPanel View. It is a full 32-bit O/S with a graphical user interface. This operating system is finding widespread application in hand-held PCs and embedded HMI s, such as the QuickPanel View. From a user s perspective, the familiar look and feel of the Windows CE environment shortens the learning curve for those having experience with Windows 95/98/NT/2000/ME/XP. From the software developer s perspective, the CE environment is a subset of the WIN32 application programming interface, simplifying the porting of existing software from other versions of Windows. The QuickPanel View operating system is stored in a 16 MB block of FLASH memory and copied to DRAM for execution. The operating system starts automatically following a power-up or reset of the QuickPanel View. For more on Windows CE visit Working with Windows CE Although the main user input device when working with Windows CE is the touch screen, it can often be convenient to use keyboard shortcuts, such as those described in the following table. Keyboard Shortcut Action CTRL+ESC or ALT+TAB CTRL+ALT+= SPACEBAR ENTER TAB SHIFT+TAB CTRL+TAB ESC Opens the Windows CE Start menu. Use arrow keys to select a program and ENTER to run it. Starts the Task Manager. Use it to quit unresponsive programs. Starts the touch screen calibration. Equivalent to single-tap. Equivalent to double-tap. In a dialog box, equivalent to OK. In a dialog box, select next control. In a dialog box, select previous control. In a tabbed dialog box, open the next tab. Close dialog box, discarding changes. ARROW KEYS In a dialog box, select controls or items from a list. GFK-2326A 6" QuickPanel View 13
22 2 Overview QuickPanel View Software To place a program in the Start menu 1. Start Windows Explorer. 2. Navigate to the program you want to place in the Start menu. 3. Tap the program s icon to select it. 4. From the Edit menu, choose Copy. 5. Navigate to the \Windows\Programs\ folder. 6. From the Edit menu, choose Paste Shortcut. 7. To save the settings, run Backup (see page 16). To configure a dial-up connection Pocket Internet Explorer Microsoft s Pocket Internet Explorer is a full featured browser that is fully integrated with the Windows CE operating system. This browser allows you to connect with an internet service provider, view Web pages and download from FTP sites. Pocket Internet Explorer supports JScript. Java support can be added from thirdparty sources. Pocket Internet Explorer does not support VBScript; however, VBScript components are included in the operating system and may be used by third-party applications such as Proficy Machine Edition. A connection can be established over an Ethernet network or a dial-up connection (default). The Ethernet or dial-up connection must be properly configured. 1. Start Pocket Internet Explorer. 2. From the Tools menu, choose Options. The Internet Options dialog box appears. 3. On the Connection tab, select the dial up connection from the combo list. 4. Tap OK. 5. To save the settings, run Backup (see page 16). 14 6" QuickPanel View GFK-2326A
23 Overview QuickPanel View Software To configure a LAN connection 1. Start Pocket Internet Explorer. 2. From the Tools menu, choose Options. The Internet Options dialog box appears. 3. On the Connection tab, select the Use LAN check box. 4. Tap OK. 5. To save the settings, run Backup (see page 16). To configure a Proxy server 1. Start Pocket Internet Explorer. 2. From the Tools menu, choose Options. The Internet Options dialog box appears. 3. On the Connection tab, select the Access the Internet using a proxy server check box. 4. In the Address box, type the URL of your proxy server (see your ISP or network administrator). 5. In the Port box, type the server s port number for HTTP access. 6. Select the Bypass Proxy for Local Addresses check box to connect directly to sites in your intranet. 7. Tap OK. 8. To save the settings, run Backup (see page 16). GFK-2326A 6" QuickPanel View 15
24 2 Overview QuickPanel View Software Backup Backup saves changes that you make to the Windows Registry or Desktop to Flash memory. This utility is required because the QuickPanel View is not battery powered. Specifically, Backup does the following: It stores the Windows CE registry (including any control panel settings) in Flash memory. It stores any changes (or additions) made to the Windows subtree of the file system in the user block of FLASH memory. Run Backup whenever you make configuration changes to the operating system or installed applications, and prior to shutting down the QuickPanel View. To run the Backup program 1. On the desktop, double-tap Backup. The Backup dialog box appears. 2. Tap OK. 16 6" QuickPanel View GFK-2326A
25 Overview QuickPanel View Software Reboot Reboot performs a controlled and orderly shut down of the Windows CE operating system, then restarts the QuickPanel View. This ensures all open files are closed properly. To reboot the system 1. To save changes to system configurations, run Backup (see page 16). 2. Tap Start, point to Programs, then the System folder, and tap Reboot A confirmation dialog box appears. 3. Tap Yes. The operating system reboots. GFK-2326A 6" QuickPanel View 17
26 2 Overview QuickPanel View Software Storage Manager Use Storage Manager to repair or format lost or corrupted data volumes. Storage Manager can repair data volumes existing either in Compact Flash (CF) or batterybacked SRAM (BBSRAM). Data volumes existing in the main flash file system of the QuickPanel View may not be repaired by Storage Manager. Storage Manager, accessed from the Control Panels folder, is a Microsoft product for which on-line help is available. System Information System Information is a custom utility that displays a splash screen with the following information: Operating System version. For example, Windows CE Platform. Identifies the host hardware, its version and build number. Tapping More Info on the splash screen opens the Advanced System Information window, which provides information such as hardware version and serial number, CPU type and specifications, etc. This information can be especially useful if you are contacting GE Fanuc Support. To run the System Information program 1. On the desktop, double-tap System Information. The System Information splash screen appears. 2. Tap More Info to open the Advanced System Information window, or tap Close to continue. Network information alone can be viewed by double-tapping the displayed on the taskbar for each connection. LAN icon Copy Project to Flash Card RestorePCCard is a custom utility for transferring Proficy TM Machine Edition TM Projects between compatible QuickPanel View units via CF cards. 18 6" QuickPanel View GFK-2326A
27 Overview QuickPanel View Software To copy a Machine Edition project onto a CF card 1. Ensure there is a blank CF card in the in the CF port. 2. Double tap the Copy Project to Flash Card icon on the desktop. 3. Tap Yes when the Proceed with Copy to CF Card confirmation dialog box appears. The system copies the project onto the blank CF Card. To update a Machine Edition project You can update a Machine Edition project currently stored on the QuickPanel View with a revision stored on a CF Card. 1. Insert the CF Card containing an upgraded version of the Machine Edition project in the CF port. 2. Reboot the machine (see page 17). The QuickPanel View automatically loads the new project from the CF Card, overwriting the old project on the machine. 3. Remove the CF Card from the slot. Emulate PPC Emulate PPC is a utility that allows the QuickPanel to emulate a Pocket PC 2003 platform during an ActiveSync session, enabling the download of third-party Pocket PC 2003 software. To use Emulate PPC during an ActiveSync session 1. Start Windows Explorer, double tap Windows, then double tap EmulPPC. The Emulate PPC dialog box appears. 2. Start the ActiveSync session. When installation of third-party software is complete, close the dialog box to deactivate Emulate PPC. HTTP File Transfer Utility The HTTP File Transfer Utility (HFTU) is a small, standalone command line program that allows you to send and delete files to and from computers over a network. The HFTU uses the HTTP protocol, so you can even send files to computers over the Internet. Run the HTTP utility from a command line prompt, from a batch file (.BAT) or as an application call in a script. The HTTP utility is an executable (.EXE) file included in the 6" QuickPanel View s operating system. GFK-2326A 6" QuickPanel View 19
28 2 Overview QuickPanel View Software The HTTP utility currently supports two file transfer commands: COPY and DELETE. Note: In order to function, the HTTP File Transfer utility requires both computers to have web servers that support PUT functionality. (Most web servers support PUT, including the Proficy Machine Edition web server installed with the runtimes for View and Logic Developer - PC.) If in doubt, check the documentation for your web server. To use the HTTP utility 1. From Programs in the Start menu, choose Programs, then choose Command Prompt. The Command Line editor appears. 2. Type commands as required. 3. Use the following syntax: HTTPUTIL COPY source destination Where source is the URL of the source file, and destination is the URL of the destination file. For example: HTTPUTIL COPY \MyFile.txt Copies a file called MyFile.txt on drive C: of the local computer to the webfiles folder under the web server at //MyServer. Note that you can rename a file as you copy it. HTTPUTIL DELETE url Where url is the remote URL of the file you want to delete. This URL must use the // or syntax. For example: HTTPUTIL DELETE Deletes a file called MyFileBACKUP.txt from the webfiles directory under the web server at " QuickPanel View GFK-2326A
29 Overview QuickPanel View Software FTP Server The FTP Server included with the QuickPanel View supports both standard (RFC 959) and Explicit FTPS (i.e., FTP/SSL, Auth TLS, TLS-C, RFC-4217). It does not support SFTP or implicit FTPS, which uses different ports and is based on SSH rather than SSL. All configuration of the FTP server is accomplished with the Secure FTP Server control panel applet. By default, the server is not enabled. Once enabled, a background program will run, waiting for clients to connect. Up to ten connections are supported. Sessions that are idle for five minutes are terminated by the server. The Server supports: Non-secure operation. All information including username, password, and data is transmitted with no encryption and susceptable to packet sniffing and various FTP attacks. This is the default. Both secure and non-secure operation. This mode of operation, either secure or non-secure, is determined by the client when it connects. This operation is active when Support Secure Connection is enabled, but Required is not. GFK-2326A 6" QuickPanel View 21
30 2 Overview QuickPanel View Software Secure operation only. Secure operation uses encrypted connections for the control connection. The data connections are encrypted or non-encrypted based on the settings of the client. Secure operations also require the server to have a signed server certificate it can use to prove it is the actual machine the client wanted to reach and not an imposter. This mode is active when both Support Secure Connection and Required are enabled. By default, the server requires a username/password combination to be configured. The server supports one username/password combination to authenticate remote users. There are three modes of authentication operation: No support for anonymous login. This is the default. Anonymous with no password. This is enabled when Allow Anonymous Access is checked, but Require Username and Password is not checked. Anonymous with password requested (but not validated). This is enabled when Allow Anonymous Access and Require Username and Password are checked. This can prevent some types of attacks and is required by some clients. Once connected, a remote user is logged into the FTP root directory. This is available from the QuickPanel View as \Temp\ftp and is a volatile RAM area. Files placed in this area are not persisted over a power cycle/reboot and use memory from the Storage Memory allocation. For this reason, remote users are only able to read, rename, and delete files from the FTP root directory. Programs running on the QuickPanel can access \Temp\ftp like any other directory, but remote users cannot fill up Storage Memory remotely. All removable flash devices appear to remote FTP users as directories off of the FTP root directory. PC Flash cards partitions appear as directories such as \PCFlashStorage. The names contain no spaces as FTP commands do not support spaces in filenames. Full access privileges are granted for the client in these folders/devices. Removable flash device directories are captured when a session is opened and are not changed while the session exists. If you start without a CF card installed, you will have to close your session and login again to see the CF directory. If the CF card existed when you logged in and is removed and inserted, it will still work provided the CF card s device name did not change during reinsertion. A server certificate is a special type of document which contains information about the server s settings and a chain of electronic signatures to guarantee the document 22 6" QuickPanel View GFK-2326A
31 Overview QuickPanel View Software has not been altered. A Server certificate must be chosen from the certificates available in the QuickPanel View Secure FTP Server control panel applet. The certificate itself is imported with the Certificates control panel applet. The main requirements of the certificate are that it must have the server authentication key usage attribute set and the name of the certificate should match the name used to connect to the FTP server (which could be the IP address of the server). Certificates can either be purchased from an online vendor and imported into the QuickPanel View, or a self-signed certificate can be generated from the QuickPanel View. The benefit of a purchased certificate is that any user that has the root certificate used by the online vendor can determine the certificate is valid without the need for any additional information. A self-signed certificate is only known to be valid by clients that have added the certificate to their trusted list. Users can still access a server using a self-signed certificate, but they lose the ability to verify that no one is operating as an imposter somewhere on the network between them and the server. To create a self-signed certificate 1. Double click the genslfcert.exe utility in the QuickPanel View/Control. 2. From the command prompt, type genslfcert CN=<unique identifier>. You may specify a unique identifier of your choice, such as machine name, machine location, or IP address in place of unique identifier. This will create a self-signed certificate in the My Certificates section of the certificates control panel and a SelfSigned.cer file in My Computer which can be transferred to FTP Clients as a trusted source. Certificates may be managed through snap-in s to the Microsoft Management Console or other third party management consoles. A Backup should be performed after configuring the FTP server and/or creating the self-signed certificate. GFK-2326A 6" QuickPanel View 23
32 2 Overview QuickPanel View Software To install a certificate on an FTP Client 1. Double click the certificate. Select the General Tab. The Certificate properties are displayed. 2. Click the Install Certificate button. The Certificate Import Wizard appears. 3. Click Next to continue. The Certificate Store screen appears. 4. Specify whether Windows should place the certificate in a certificate store or select another location. Click Next to continue. The Completing the Certificate Import Wizard screen appears. 5. Click Finish to complete the installation of the certificate. The Security Warning message appears. This message informs you Windows will automatically trust any certificate issued by this Certification Authority. 6. Click Yes to allow Windows to trust any certificate issued by this Certification Authority. 24 6" QuickPanel View GFK-2326A
33 3 Detailed Operation Touch Screen Display To adjust the display contrast 26 To set backlight for auto turn off 27 To calibrate the touch screen 28 To set the double-tap sensitivity 29 Keyboard To show/hide the Soft Input Panel 31 To display the Soft Input Panel icon in the system tray 31 To change key configurations 34 To reset SIP location 34 Communication Port To add a new remote networking serial connection 38 To add a virtual private network or PPP over Ethernet 39 To change the default device properties 40 To change the default TCP/IP settings 41 CF Port Ethernet To set an IP address 44 To set up access to a Windows network 45 To access a remote resource on a Windows network 46 Expansion Bus DIP Switches To configure startup behavior with DIP switch 2 48 Memory To add External Flash memory with a CF Card 50 To change the DRAM memory allocation 51 To install additional DRAM 53 Other Subsystems To access the Power Properties control panel 54 To remove the internal battery 55 To set the real-time clock 55 To display the time on the taskbar 56 To set SNTP 57 GFK-2326A 6" QuickPanel View 25
34 3 Detailed Operation Touch Screen Display TOUCH SCREEN DISPLAY The QuickPanel View has an integrated flat-panel color or monochrome display, depending on model. The color model is backlit, measures 5.7" diagonally, and uses passive STN technology. The monochrome model is backlit, measures 5.7" diagonally, and uses passive FSTN technology. The resolution of the color display is 320 x 240 pixels and 65,536 colors; the resolution of the monochrome display is 320 x 240 pixels and 256 shades of gray. A backlight timer is featured on all models. You can extend backlight life by turning the backlight off automatically. 240 pixels 320 pixels To adjust the display brightness (color models only) 1. In the Control Panel, double-tap Display and choose the Brightness tab. The Brightness dialog box appears. 26 6" QuickPanel View GFK-2326A
35 Detailed Operation Touch Screen Display 2. Drag the Brightness slider between Lowest and Highest. 3. Tap OK to exit the control panel. 4. To save the settings, run Backup (see page 16). To adjust the display contrast (monochrome models only) 1. In the Control Panel, double-tap Display and choose the Contrast tab. The Contrast dialog box appears. 2. Drag the Contrast slider between Lowest and Highest. 3. Tap OK to exit the control panel. 4. To save the settings, run Backup (see page 16). To set backlight for auto turn off 1. In the Control Panel, double-tap Display and choose the Backlight tab. The Backlight dialog box appears. 2. Select Auto turn off backlight while on external power. 3. Tap OK to exit the control panel. 4. To save the settings, run Backup (see page 16). GFK-2326A 6" QuickPanel View 27
36 3 Detailed Operation Touch Screen Display Touch Screen The QuickPanel View display is coupled to a resistive touch panel with 12-bit resolution. When the QuickPanel View is properly calibrated, this translates into a grid of touch cells on the face of the display. Although you can use your finger to activate the touch screen, use of a blunt stylus is recommended. 240 cells 320 cells To calibrate the touch screen 1. In the Control Panel, double-tap Stylus. The Stylus Properties dialog box appears. 2. Choose the Calibration tab. 3. Tap the Recalibrate button. A cross hair target is displayed. 28 6" QuickPanel View GFK-2326A
37 Detailed Operation Touch Screen Display 4. Follow the directions given to calibrate the touch screen. 5. Tap the screen to preserve the new setting or wait out the time limit to revert to previous settings. 6. To save the settings, run Backup (see page 16). To set the double-tap sensitivity 1. In the Control Panel, double-tap Stylus. The Stylus Properties dialog box appears. GFK-2326A 6" QuickPanel View 29
38 3 Detailed Operation Touch Screen Display 2. Choose the Double-Tap tab. 3. Double-tap the grid to enter a setting. 4. Double-tap the test icon to check the setting. If the test icon doesn t change when you double-tap it, double-tap the grid again. 5. Tap OK to finish. 6. To save the settings, run Backup (see page 16). 30 6" QuickPanel View GFK-2326A
39 Detailed Operation Keyboard KEYBOARD The QuickPanel View can be configured to use a software emulation keyboard as a operator data input devices.. Soft Input Panel The Soft Input Panel (SIP) is a touch screen version of a standard keyboard, which can be used in place of a standard hardware keyboard. An icon in the system tray lets you view or hide the SIP. Show Input Panel icon To show/hide the Soft Input Panel On the system tray of the task bar, double-tap the icon. The Soft Input Panel appears/disappears. Note: When the SIP is visible, it can be dragged around the screen by its title bar to reveal different parts of the screen that would be obstructed from view by the SIP. To display the Soft Input Panel icon in the system tray 1. In the Control Panel, double-tap Input Panel. The Input Panel Properties dialog box appears. 2. Select the Allow applications to change the input panel state check box. 3. Select or clear the Show Input Panel in system tray check box. 4. Tap OK. 5. To save the settings, run Backup (see page 16). The Soft Input Panel has two basic configurations: Small key and Large key. GFK-2326A 6" QuickPanel View 31
40 3 Detailed Operation Keyboard Small Key configuration: Provides a standard QWERTY key layout with numeric keys at the top row as illustrated in the following picture. Small key: lower case Uppercase characters are accessed by pressing the SHIFT key once. This is equivalent to holding down the SHIFT key on a conventional keyboard. The SHIFT key is active while the next key is pressed then reverts back to its unselected state. The CAP key does the same thing as SHIFT but does not revert to lower case after another key is pressed. Rather, the Soft Input Panel remains in the Uppercase mode until the CAP key is pressed again. The CTRL and ALT keys behave the same as the SHIFT key. Small key: upper case Large Key configuration: Provides alphabetic or numeric keys alone. No numeric keys are displayed at the top of the alpha panel; alpha keys are not displayed on the numeric panel. Large key: lower case 32 6" QuickPanel View GFK-2326A
41 Detailed Operation Keyboard As with the small key configuration, upper or lower case alpha keys can be displayed by using the SHIFT key. Large key: upper case Pressing the 123 key once locks the panel in numeric mode until the 123 key is pressed again. Large key: numeric GFK-2326A 6" QuickPanel View 33
42 3 Detailed Operation Keyboard To change key configurations 1. In the Control Panel, double-tap Input Panel. The Input Panel Properties dialog box appears. 2. From the Current input method list, choose CE Keyboard. 3. Tap Options. The Soft Keyboard Options dialog box appears. 4. Select Large Buttons or Small Keys. A preview of the key size is displayed on the dialog box. 5. Tap OK twice to finish. 6. To save the settings, run Backup (see page 16). To reset SIP location In the event the user accidentally drops the SIP off screen and can t drag it back on screen, the following steps will reset the SIP to the centre of the screen. 1. In the Control Panel, double-tap Input Panel. 34 6" QuickPanel View GFK-2326A
43 Detailed Operation Keyboard The Input Panel Properties dialog box appears. 2. Select Reset SIP location. GFK-2326A 6" QuickPanel View 35
44 3 Detailed Operation Communication Port COMMUNICATION PORT The QuickPanel View has one serial data communication port (COM1). COM1- Serial The COM1 port is a general purpose bidirectional serial data channel that supports the EIA232C and EIA485 electrical standards. The COM1 port can be accessed and configured: as a direct or dial-up remote networking connection. from a user-created application program. A connection can be configured to reside on a network supporting a TCP/IP protocol. A DB25S (female) connector, mounted on the bottom of the enclosure, provides standard signals as described in the following table. Bottom 1 GND - Frame Ground 14 VCC - 5VDC, 0.5A 2 TX - (EIA232C) 15 TXB (EIA485) 3 RX - (EIA232C) 16 RXB (EIA485) 4 RTS - (EIA232C) 17 n/c 5 CTS - (EIA232C) 18 CSB (EIA485) 6 DSR - (EIA232C) 19 ERB (EIA485) 7 SG - Signal Ground 20 DTR (EIA232C) 8 DCD - (EIA232C) 21 CSA (EIA485) 9 TRMRXB (EIA485) 22 ERA (EIA485) 10 RXA (EIA485) 23 n/c 11 TXA (EIA485) 24 n/c 12 n/c 25 n/c 13 n/c Note: Pin 14 is fused with a field-replaceable, 1.0A fast-blow fuse. Recommended Cabling for TIA/EIA422 or TIA/EIA485 The COM1 port on the QuickPanel View provides connections to devices, which support either TIA/EIA422 or TIA/EIA485. These electrical standards specify a differential signaling technique which provides high data rates, long distances and good noise rejection. The standards do not address signal encoding (protocol), connectors, or cabling. However, certain characteristics of interfacing these devices should be considered in order to ensure reliable connections. 36 6" QuickPanel View GFK-2326A
45 Detailed Operation Communication Port Connections Interconnect media Termination Grounding Connect nodes in a daisy chain fashion. Do not connect in other arrangements, especially "star." The standards do not specify the maximum number of nodes or devices that can be connected to a TIA/EIA 422 or 485 network. Instead, the standards limit the number of electrical connections by specifying that a maximum of 32 unit loads (UL) may be connected. The QuickPanel View presents one UL. Always use twisted pair cabling and group complimentary signals into conductor pairs; TXA with TXB, for example. Use a cable with a characteristic impedance of 100 ohms to 120 ohms. A wire gauge of 24 AWG is commonly used. Maximum cable length is 4,000' (1,219.2m), but may be less due to cable impedance, connection quality, data rates, and other factors. Shield is optional. See Shielding on page 38. Always provide proper termination at each end of the 422/485 network. The QuickPanel View provides built-in termination resistance when pin #9 (TRMRXB) is connected to pin #10 (RXA). Caution: Do not terminate every node. Only terminate the end nodes. A signal return path between transmitting and receiving devices must be provided. This return path is separate from the Rx and Tx data lines and the other 422/485 signals supported by the QuickPanel View, and may be provided by a separate conductor in the cable. Connect both ends of the signal return conductor to Signal Ground (pin #7). Shielding or use of a twisted pair for this connection is not necessary. For installations where all devices are in the same cabinet and have the same ground potential between devices, connecting Signal Ground between all the devices on the 422/485 network is adequate to ensure proper voltage levels at the devices. However, if there is a difference in ground potential between devices, such as when the devices are in widely separated cabinets, then signal grounds on a 422/485 network should not be tied together. The cable shield and cable ground should be connected together at only one device, closest to the earth ground connection. The signal and frame grounds of the QuickPanel View are capacitively coupled, but in some devices these ground references are connected together. Connect Signal Ground (pin #7) to Frame Ground (pin #1) and then to earth ground on the QuickPanel View only in the circumstance where the other devices separate their signal and frame grounds and the QuickPanel View is the only device with frame and signal ground connected to earth ground. GFK-2326A 6" QuickPanel View 37
46 3 Detailed Operation Communication Port Shielding Shielded cable is required for compliance with CE and FCC requirements. The cable shield should be connected to the metal connector shell or by pin #1 of the QuickPanel 25-pin serial connector. Shield and cable ground (pin #7 of the 25-pin connector or pin #5 of the 9-pin connector) should not be connected directly together. The Frame Ground (pin #1) of the QuickPanel View should be used for attaching the cable shield in these applications. Caution: Do not connect Signal Ground (pin #7) to Frame Ground (pin #1) on the QuickPanel View, except in the specific and limited circumstances noted in the Grounding section on page 37. Working with the COM port To add a new remote networking serial connection 1. From the Start menu, tap Settings, then Network and Dial-up Connections. The Connection window appears. 2. Double-tap Make New Connection. The Make New Connection wizard appears. 3. Type a name for the new connection. 4. Choose a connection type. If you are configuring a Modem, choose Dial-Up Connection. If you have a Device, select Direct Connection. 5. Tap Next. 38 6" QuickPanel View GFK-2326A
47 Detailed Operation Communication Port The Modem or Device Connection window appears, depending on the connection type. or 6. From the list, choose the modem or device you want to use. (If a serialcf card is inserted, it is available in the device list). You can Configure your device or TCP/IP Settings at this time if you wish. 7. Tap Finish for direct connection (Device dialog box) or Next for dial-up (Modem dialog box). If you are adding a dial-up connection the following dialog box appears. 8. Type the destination Country/region code, Area code, and Phone number in the appropriate boxes. 9. Select or clear the Force Long Distance or Force Local check boxes. 10. Tap Finish. To add a virtual private network or PPP over Ethernet 1. From the Start menu, tap Settings, then Network and Dial-up Connections. The Connection window appears. 2. Double-tap Make New Connection. GFK-2326A 6" QuickPanel View 39
48 3 Detailed Operation Communication Port The Make New Connection wizard appears. 3. Type a name for the new connection. 4. Choose a connection type. Select Virtual Private Network to configure a VPN connection. Select PPP over Ethernet for a PPPoE connection. 5. Tap Next. The VPN or PPPoE Connection window appears, depending on the connection type. or 6. Enter the Host Name or IP address for a VPN connection, or a PPPoE Service Name for a PPPoE connection. You can configure your TCP/IP Settings at this time if you wish. 7. Tap Finish. To change the default device properties 1. From either the Device or Modem dialog box, tap Configure. 40 6" QuickPanel View GFK-2326A
49 Detailed Operation Communication Port The Device Properties dialog box appears. 2. In the Port Settings tab, choose settings for all connection preferences. 3. If the connection is for terminal emulation, select or clear the terminal-related check boxes. You can use the QuickPanel View to emulate a terminal attached via a modem link (Hayes compatible) to COM1. A terminal emulation definition is added as a unique session. To change the default TCP/IP settings 1. Obtain correct TCP/IP settings from your network administrator. 2. From either the Device, Modem, PPPoE Connection, or VPN Connection dialog box, tap TCP/IP Settings. The TCP/IP Settings dialog box appears. 3. Use the TCP/IP settings from your internet provider. GFK-2326A 6" QuickPanel View 41
50 3 Detailed Operation CF Port CF PORT To enhance the QuickPanel View s capabilities with additional flash memory, the unit is equipped with a CF (Compact Flash) Type 2 port on its side. Right Side Compact Flash Port A CF card is inserted in this port with its front facing the front panel of the unit (the narrow side slot on the card should be toward the top). The card should slide in easily to avoid damage, do not force it. Note: For full protection from electrostatic discharge, peel off the paper label on the side of the CF card facing away from the bezel to allow contact between the card and the internal frame ground contacts on the CF connector. The Copy Project to Flash Card utility (see page 20) lets you transfer Machine Edition projects between QuickPanel View units via CF Cards. No Compact Flash cards are supplied with the QuickPanel View. A list of cards (and other devices) that have been tested and are compatible can be found by visiting then select the Operator Interface category, then select the QuickPanel View product name. The CF port in the QuickPanel View only supports 3.3v CF cards. 5v CF cards are not suported. Caution: Do not remove power while the system is writing to the CF card, such as when copying a Proficy Machine Edition project. Removing power while writing may lead to data loss and file or CF card corruption. To ensure the system completes writing to flash and closes all files, see Shutdown on page " QuickPanel View GFK-2326A
51 Detailed Operation Ethernet ETHERNET The QuickPanel View is equipped with a 10BaseT/100BaseTx auto-negotiate Ethernet port (IEEE802.3), and you can connect an Ethernet network cable (unshielded, twisted pair, UTP CAT 5) to the unit via the RJ45 connector on the bottom of the enclosure. LED indicators on the port indicate channel status. Access to the port is possible either by Windows CE network communications, or by your custom application. The following diagram shows the location, orientation, and pin out of the Ethernet port. Bottom 1 TX_D1 + 2 TX_D1-3 RX_D2 + 4 B1_D3 + 5 B1_D3-6 RX_D2-7 B1_D4 + 8 B1_D4 - Activity LED (on: packet received or transmitted) Link LED (on: channel connected ok) There are two methods for setting an IP address on the QuickPanel View: DHCP (Dynamic Host Configuration Protocol). This is the default method that is carried out automatically. Note: There must be a DHCP server on the connected network for a valid IP address to be assigned. Contact your network administrator to ensure correct DHCP server configuration. Manual method. The user uniquely specifies the numeric addresses for the QuickPanel View, the Subnet Mask (if applicable), and the Default Gateway. Note: Use a crossover cable to connect the QuickPanel View to a PC directly; when connecting to a LAN HUB, use a straight through cable. Contact your network administrator if you require further information. GFK-2326A 6" QuickPanel View 43
52 3 Detailed Operation Ethernet To set an IP address 1. From the Control Panel, tap Network and Dial-up Connections. The Connection window appears. 2. Select a connection and choose Properties. The Built-in Ethernet Port Settings dialog box appears. 3. Select a method: Obtain an IP address via DHCP (automatic). Specify an IP address (manual). 4. Enter the IP Address, Subnet Mask and Default Gateway numbers obtained from your network administrator (manual method only). 5. Tap OK. 6. To save the settings, run Backup (see page 16). If the DHCP method was selected, the network server will assign an IP address while the QuickPanel View is initializing. (You must be connected to the network). After setting an IP address for the QuickPanel View, you can access any network drives or shared resources for which you have permission. 44 6" QuickPanel View GFK-2326A
53 Detailed Operation Ethernet To set up access to a Windows network 1. In the Control Panel, double-tap System. The System Properties dialog box appears. 2. On the Device Name tab, in the Device name box, type a unique name for your QuickPanel View. In the Device description box, type a description. 3. Tap OK. 4. In the Control Panel, double-tap Owner. The Owner Properties dialog box appears. 5. On the Network ID tab, type your assigned User name, Password and Domain. 6. Tap OK. 7. To save the settings, run Backup (see page 16). GFK-2326A 6" QuickPanel View 45
54 3 Detailed Operation Ethernet Using Windows CE Explorer, you can now access anything on your local network for which you have permission. To access a remote resource on a Windows network 1. Start Windows Explorer. The Explorer window appears. 2. Type in the Address box, or choose from a list, the path to a remote resource. For example \\MyRemoteComputer\MyFolder specifies the folder named MyFolder on a computer with the name MyRemoteComputer. 3. Press ENTER. The resource specified is displayed as a collection of files and folders. It can take a few moments to retrieve the data from your local network. Note: You can use the NET command from the shell to map a network resource to the QuickPanel View for frequent access. The resource then appears in the Network folder. 46 6" QuickPanel View GFK-2326A
55 Detailed Operation Expansion Bus EXPANSION BUS An expansion bus is included with the QuickPanel View, and optional modules that mount directly to it are available. For more information on expansion modules, contact your distributor. The expansion bus connectors are accessed by opening the back of the unit. Back (open) Expansion Bus Caution: Remove power from the QuickPanel View before opening the back. Working on a live unit may result in damage to equipment and injury to personnel. Always use anti-static precautions (i.e. grounded wrist strap) when accessing the interior of the unit. Do not allow conductive material, liquid or solid, to contact the electronics of the QuickPanel. Caution: Ensure all pins are properly aligned when inserting expansion cards. Misalignment could cause damage to the QuickPanel View and/or the expansion card. GFK-2326A 6" QuickPanel View 47
56 3 Detailed Operation DIP Switches DIP SWITCHES The QuickPanel View is equipped with four DIP switches that each control separate functions. DIP switches are set to OFF by default in the factory. DIP switch 2 is the Force Startup switch. Turning this switch on forces the startup applications to run when the operating system is started. Back (open) Dip Switches Force Startup When the switch is set to OFF, the QuickPanel View operates normally, displaying the startup splash screen. You can skip running the startup applications by tapping the Don t run StartUp Programs button on the startup splash screen. When the switch is set to ON, the startup programs are forced to run and the Don t run Startup Programs button is not available on the startup splash screen. Note: Do not adjust switches other than switch 2. They are reserved for factory functions. To configure startup behavior with DIP switch 2 Caution: Remove power from the QuickPanel View before opening the back. Working on a live unit may result in damage to equipment and injury to personnel. Always use anti-static precautions (i.e. grounded wrist strap) when 48 6" QuickPanel View GFK-2326A
57 Detailed Operation DIP Switches accessing the interior of the unit. Do not allow conductive material, liquid or solid, to contact the electronics of the QuickPanel. 1. Open the back cover of the QuickPanel View. 2. Locate the DIP switches and set DIP switch 2 to ON. The startup applications are now forced. Note: Do not adjust the other switches. They are reserved for factory functions. GFK-2326A 6" QuickPanel View 49
58 3 Detailed Operation Memory MEMORY The QuickPanel View supports a variety of memory subsystems to ensure the requirements of your application are met. All system memory is tied directly to the microprocessor s address and data busses for fastest access. To increase DRAM by up to 64 MB, a 100-pin DIMM memory expansion slot is also included. Flash Memory To add External Flash memory with a CF Card This 32 MB block of non-volatile memory is the main long-term program storage for the QuickPanel View, operating like a virtual hard drive from the point of view of Windows CE. It is divided into two areas, of which only one is accessible from Windows CE Explorer. The Flash Storage folder represents a 16 MB block of memory available for long-term storage of user application programs. Another 16 MB block is used to store the Windows CE operating system, and is not directly accessible from Windows CE Explorer. The operating system and all user application programs are transferred from Flash to DRAM for execution. Any user additions to the Windows folder are retained in Flash Storage when the Backup utility is run. FLASH memory has a limited write-cycle lifetime. That is, the physical memory devices wear out after approximately 100,000 cycles (minimum), so it is advisable to limit file operations such as copy, delete, etc. The write cycle is much slower for FLASH than it is for other portions of RAM, therefore FLASH is not recommended for the storage of program variables, or any data items whose values are dynamic. Flash memory can optionally be added with a CF Card, which will appear as the PCFlash Storage folder. Caution: Do not remove power while the system is writing to flash memory, such as when downloading a Proficy Machine Edition project. Removing power while writing may lead to data loss and file system corruption. To ensure the system completes writing to flash and closes all files, see Shutdown on page -4. Insert a Compact Flash card into CF Port (see page 42). The unit immediately reads the new secondary storage. If the disk requires formatting, you will be prompted to do so. New memory appears in Windows CE Explorer as PCFlash Storage. 50 6" QuickPanel View GFK-2326A
59 Detailed Operation Memory External flash memory devices are named after their types of connection and order of attachment. For example, if you connect two flash memory devices, one via the CF port and one via the fieldbus connector, the first device connected device is named PCFlash Storage, and the second device is named PCFlash Storage2. At powerup, a CF port device is recongnized and named first. Otherwise, the name depends on connection order. SRAM Memory This 512 KB block of static RAM is battery-backed to provide data retention through a power cycle. This memory block is shared by the operating system and user applications. A portion of the SRAM memory, represented as the SRAM Storage folder, operates as a virtual hard drive and is accessible from the Windows CE Explorer. Typical application programs create files in this folder in which to store critical program data. The portions of SRAM memory used by the operating system and by user applications varies between models. DRAM Memory The QuickPanel View is equipped with 32 MB of dynamic RAM. Part of the DRAM (13.2 MB) is reserved for the Windows CE operating system and is not accessible by user applications. The other 18.8 MB is split between two functions: an object store for temporary file storage, and the main memory for running programs. Typically, compressed programs stored in FLASH are expanded and moved to DRAM for execution. Temporary storage of program variables or data files is also provided by DRAM any data stored in DRAM will not be retained through a power cycle. The split between program memory and storage memory may be adjusted as necessary to make more room for one or the other, depending on your specific application needs. For example, if you find that an application is short of memory, use the System Properties dialog box to alter DRAM memory allocation. Caution: Setting Program Memory too low may prevent additional applications from starting, or may cause currently running applications to fail due to lack of memory. Setting Storage Memory too low may prevent the saving of files into the object store portion of the file system, which may also cause application failures. To change the DRAM memory allocation 1. In the Control Panel, double-tap System. GFK-2326A 6" QuickPanel View 51
60 3 Detailed Operation Memory The System Properties dialog box appears. 2. On the Memory tab, drag the slider to divide the DRAM into Storage and Program memory. The amount of memory allocated to and used by each area is displayed numerically. The blue bar indicates the current amount of unallocated DRAM and determines the boundaries within which the slider can move. 3. Tap OK to apply the new setting. 4. To save the settings, run Backup (see page 16). Boot Loader ROM The Boot Loader ROM provides 512 KB of non-volatile storage for the QuickPanel View s initialization program. This program configures the QuickPanel View hardware then starts the operating system s execution. This memory is not accessible from Windows CE Explorer, nor should any attempts be made to modify the contents of this ROM. Memory Expansion Slot The QuickPanel View is equipped with a 100-pin DIMM memory expansion slot which lets you increase DRAM to a total of 96 MB. Rear (open) Memory Expansion Slot Caution: Remove power from the QuickPanel View before opening the back. Working on a live unit may result in damage to equipment and injury to personnel. Always use anti-static precautions when accessing the interior of the 52 6" QuickPanel View GFK-2326A
61 Detailed Operation Memory QuickPanel View. Do not allow conductive material, liquid or solid, to contact the electronics of the QuickPanel. To install additional DRAM 1. Disconnect AC power from the 24VDC supply. 2. Open the rear access panel. 3. Insert the new DIMM carefully into the expansion slot, noting the orientation of the pin locators. When the DIMM is fully seated, lift each side clip until it clicks into place. GFK-2326A 6" QuickPanel View 53
62 3 Detailed Operation Other Subsystems OTHER SUBSYSTEMS Power Management The QuickPanel View s Power Properties control panel displays the status of the backup battery. The Battery Very Low Or Missing icon displays in the taskbar when the battery is either missing or very low. To access the Power Properties control panel 1. In the Control Panel, double-tap Power. The Power Properties dialog box appears. Battery Backup Auxiliary backup power for the real-time clock and SRAM is provided by a nonrechargeable, internal lithium battery (+3VDC, BR2032), ensuring that no loss of data occurs when the main 24VDC supply is removed. Backup power is enabled or disabled by installing or removing the battery, accessed via the rear panel as shown in the following illustration. Rear (open) Internal Battery Caution: Remove power from the QuickPanel View before opening the back. Working on a live unit may result in damage to equipment and injury to personnel. Always use anti-static precautions when accessing the interior of the QuickPanel View. Do not allow conductive material, liquid or solid, to contact the electronics of the QuickPanel. 54 6" QuickPanel View GFK-2326A
63 Detailed Operation Other Subsystems To remove the internal battery 1. Disconnect AC power from the 24VDC supply. 2. Open the rear access panel. 3. Release the battery by gently lifting it from the completely exposed side, past the small protrusions. To avoid breaking the battery retainer clips, do not apply excessive upward pressure. 4. Slide the battery out of its carrier, noting the arrow on the carrier indicating the direction of removal. Real-time Clock The QuickPanel View has a programmable real-time clock capable of reporting the current time in Year/Month/Day/Hour/Minute/Second. The time is set from the Windows CE interface and retained through a power cycle if battery backup is available. Automatic adjustment for daylight savings time is enabled by a check box within the dialog box. The time can be displayed in the system tray on the task bar. Help for this dialog box is activated by selecting the question mark. To set the real-time clock 1. In the Control Panel, double-tap Date/Time. The Date/Time Properties dialog box appears. Note: Tap Apply after making changes in any box. 2. To modify the date, select the Date/Time tab. 3. Tap the year to choose a new year; tap the month to choose a new month. 4. Tap a date to specify the day of month. 5. From the Time Zone box, choose your zone. 6. Select Auto Adjust DST to have the clock automatically compensate for daylight savings time. 7. In the Current Time box, adjust the hours, minutes and seconds. 8. Tap OK to finish. The time can be displayed in the system tray on the task bar. GFK-2326A 6" QuickPanel View 55
64 3 Detailed Operation Other Subsystems To display the time on the taskbar 1. From the Start menu, choose Settings, then Taskbar and Start Menu... The Taskbar Properties dialog box appears. 2. On the Taskbar Options tab, select Show Clock. 3. Tap OK. An hours and minutes display now appears in the taskbar. Clock Display Configuring SNTP There are two levels of Network Time Protocol (NTP) time servers available on the Internet. First-level time servers are primarily intended to act as source time servers for second-level time servers. First-level time servers may also be capable of providing mission-critical time services. Some first-level time servers may have a restricted access policy. Second-level time servers are intended for general SNTP time service needs and usually enable public access. It is recommended that you use second-level time servers for normal SNTP time server configuration because they are normally located on a closer network that can produce faster updates. It is recommended that you research any time server selection to ensure that it can meet your specific time server requirements. More information and a list of SNTP time servers can be found at If the time on the time server is more than the threshold value away from the current time on the QuickPanel View, then the time is not updated. Setting the Threshold to 0 tells the utility to always accept the time from the server. This setting would be useful in a case where the backup battery has died and the QuickPanel View was power cycled, since the internal clock would have reset back to January 1, :00 am. 56 6" QuickPanel View GFK-2326A
65 Detailed Operation Other Subsystems To set SNTP 1. In the Control Panel, double-tap Date/Time. The Date/Time Properties dialog box appears. Note: Tap Apply after making changes in any box. 2. To add or modify SNTP settings, select the SNTP tab. 3. To enable SNTP, ensure the Enable SNTP check box is selected. 4. Enter the time server name in the Server(s) field. 5. Set the Refresh, Retry, and Threshold parameters. 6. Tap Update Now to update SNTP settings immediately. 7. Tap OK to finish. GFK-2326A 6" QuickPanel View 57
Hardware User s Guide
Hardware User s Guide 6 QuickPanel View Keypad IC754VSI06SKD IC754VGI06SKD IC754VBI06SKD January 2005 GFK-2357 All rights reserved. No part of this publication may be reproduced in any form or by any
More informationHardware User s Guide
Hardware User s Guide 6 QuickPanel View Basic, monochrome, round bezel IC754VSB06MTD IC754VBB06MTD January 2007 GFK-2327A All rights reserved. No part of this publication may be reproduced in any form
More informationHardware User s Guide
Hardware User s Guide 6 QuickPanel View IC754VSI06STD IC754VBI06STD IC754VSI06MTD IC754VBI06MTD May 2004 GFK-2325 All rights reserved. No part of this publication may be reproduced in any form or by any
More informationHardware User s Guide
Hardware User s Guide 6 QuickPanel Control & 6 QuickPanel View Loaded, color TFT & monochrome, round bezel IC754CSL06CTD IC754CBL06CTD IC754VSL06CTD IC754VBL06CTD IC754OBL06CTD IC754OTL06CTD IC754CSF06CTD
More informationHardware User s Guide
Hardware User s Guide 6 QuickPanel Control & 6 QuickPanel View IC754CSL06CTD IC754CBL06CTD IC754VSL06CTD IC754VBL06CTD IC754OBL06CTD IC754OTL06CTD IC754CSF06CTD IC754CSF06MTD May 2004 GFK-2243D All rights
More informationHardware User s Guide
Hardware User s Guide 6 QuickPanel View IC754VGB06MTD IC754VHB06MTD May 2004 GFK-2328 All rights reserved. No part of this publication may be reproduced in any form or by any electronic or mechanical
More informationHardware User s Guide
Hardware User s Guide 6 QuickPanel View IC754VSB06MTD IC754VBB06MTD May 2004 GFK-2327 All rights reserved. No part of this publication may be reproduced in any form or by any electronic or mechanical
More informationHardware User s Guide
GE Intelligent Platforms Hardware User s Guide 6 QuickPanel Control & 6 QuickPanel View Loaded, color TFT & monochrome, round bezel IC754CSL06CTD IC754CBL06CTD IC754VSL06CTD IC754VBL06CTD IC754OBL06CTD
More information6" QuickPanel* View Basic, Monochrome, Round Bezel
GE Intelligent Platforms Operator Interface Products 6" QuickPanel* View Basic, Monochrome, Round Bezel IC754VSB06MTD IC754VBB06MTD Hardware User's Guide, GFK-2327B September 2010 Warnings, Cautions, and
More informationGE Fanuc Intelligent Platforms Operator Interface Products. 2Hardware User s Guide
GE Fanuc Intelligent Platforms Operator Interface Products 0H8 QuickPanel View and 8 QuickPanel Control 1HFully Loaded Color TFT IC754VBF08CTD IC754VGF08CTD IC754CBF08CTD IC754CGF08CTD IC754OBF08CTD IC5008CAC0000
More informationQuickPanel View & QuickPanel Control
GE Fanuc Automation Operator Interface Products QuickPanel View & QuickPanel Control PCMCIA Adapter IC754PCMCIA001-A Hardware User s Guide, GFK-2368 June 2005 GFK-2368 PCMCIA Host Adapter GFL-002 Warnings,
More informationQuickPanel* View Communication Module Hardware User s Guide
PROFIBUS Slave Adapter IC754PBSS01 QuickPanel* View Communication Module Hardware User s Guide April 2010 GFK-2291B GFL-002 Warnings, Cautions, and Notes as Used in this Publication Warning Warning notices
More informationControlStation CEIIx Communication Module Quick Install Guide
PCIF I/O Adapter BBSRAM Adapter Profibus Adapter DeviceNet Adapter ControlStation CEIIx Communication Module Quick Install Guide April 2002 A All rights reserved. No part of this publication may be reproduced
More informationStacking Module. Installation Guide AT-MCF2000S. PN Rev A
Stacking Module AT-MCF2000S Installation Guide PN 613-000708 Rev A Copyright 2007 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission
More informationInstalling and Configuring Rialto Analytic Appliances
Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation
More informationMercury Helios ASSEMBLY MANUAL & USER GUIDE
Mercury Helios ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards NOTE: Boot Camp
More information3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions
3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These
More informationhdpv.org Ampt Communications Unit Installation Manual D
hdpv.org Ampt Communications Unit Installation Manual 57070008-1 D 2 Copyright 2016-2019 Ampt LLC. All rights reserved. No part of this document may be reproduced, retransmitted, or copied in any form
More information4170 POS System Installation Guide
4170 POS System 4170 Installation Guide Thank you for selecting UTC RETAIL s innovative Model 4170 Point of Sale solution! This Installation Guide will help you efficiently install the 4170 POS. The document
More informationTABLE OF CONTENTS INTRODUCTION...1 DEVICE SETUP...4 SUPPORT RESOURCES...9
TABLE OF CONTENTS INTRODUCTION...1 1.1 Minimum System Requirements 1.2 Package Contents 1.3 About This Manual 1.4 Rear View 1.4.1 Rear Features 1.5 Usage Notes DEVICE SETUP...4 2.1 Quick Start 2.2 Assembly
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-COM Modules Installation Guide UAC-01RS2,UAC-02RS2,UAC-02RSC Uni-COM is a family of communication modules that are compatible with the UniStream control platform. This guide provides basic installation
More informationOWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE
OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS 1. INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2
More informationMercury Elite Pro mini ASSEMBLY MANUAL & USER GUIDE
Mercury Elite Pro mini ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS 1. INTRODUCTION... 1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Mac Requirements 1.1.2 PC Requirements 1.2 PACKAGE CONTENTS 1.3 ABOUT THIS
More informationF1000 User's Manual. (Version: V1.01)
(Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UIS-04PTN Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for
More informationManual Version: V1.00. Video Decoder User Manual
Manual Version: V1.00 Video Decoder User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang
More informationPM Series Power Meter
PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UID-0808THS Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UIA-0402N Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for
More informationQUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.
PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA
More informationProficy* Workflow. Powered by Proficy SOA GETTING STARTED
Proficy* Workflow Powered by Proficy SOA GETTING STARTED Version 1.5 SP4 February 2012 All rights reserved. No part of this publication may be reproduced in any form or by any electronic or mechanical
More informationOWC Mercury On-The-Go Pro USER GUIDE
OWC Mercury On-The-Go Pro USER GUIDE TABLE OF CONTENTS 1. INTRODUCTION... 1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.2 PACKAGE CONTENTS 1.3 ABOUT THIS MANUAL
More informationMT8050iE series. Installation Instruction (1) (2)
MT8050iE series 3 Installation Instructions Installation Instruction Secure the operator panel in position, using all the fastening holes and the provided brackets and screws: (A) 1 Installation and Startup
More informationStandalone Voice/IP Gateway Model MVP110. Proprietary Mode. Quick Start Guide
Voice / Fax over IP Networks 100 Standalone Voice/IP Gateway Model MVP110 Proprietary Mode Quick Start Guide Quick Start Guide 82050750 Revision A MultiVOIP 100 (Model MVP110) This publication may not
More informationCncGcoder Models HD & HDx Manual
CncGcoder Models HD & HDx Manual Table of Contents WELCOME... 3 IN THE BOX... 4 Optional Accessories...4 HANDHELD OVERVIEW... 5 Overview...5 Charging the Battery...6 Turning On and Off...6 Plugging in
More information8380 RPC Return Path Combiner. User s Guide
8380 RPC Return Path Combiner User s Guide Notice Every effort was made to ensure that the information in this manual was accurate at the time of printing. However, information is subject to change without
More informationUser Manual CL
User Manual CL-1200 Warning! This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. This equipment
More informationManagement Software AT-S79. User s Guide. For use with the AT-GS950/16 and AT-GS950/24 Smart Switches. Version Rev.
Management Software AT-S79 User s Guide For use with the AT-GS950/16 and AT-GS950/24 Smart Switches Version 1.0.0 613-000207 Rev. A Copyright 2005 Allied Telesyn, Inc. All rights reserved. No part of this
More informationQuick Start Installation Guide
apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building
More informationPACSystems RX7i IC698CHS009/119
January 2010 The RX7i rack can be used for all RX7i CPU and I/O configurations, Series 90-70 I/O, and VME modules. Backplane connectors are spaced on 0.8" (20.3mm) centers to accommodate single-width RX7i
More informationWebRamp M3 Quick Start. for Windows and Macintosh
WebRamp M3 Quick Start for Windows and Macintosh Copyright 1997 Ramp Networks, Inc. All rights reserved. This publication, as well as the software described in it, is furnished under license and may only
More informationHEC. General Operating, Maintenance and Installation Manual
HEC General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet : http://www.ipcomm.de Email: info@ipcomm.de Edition November 2005 Version
More informationTHUNDERBAY 4 MINI. Assembly Manual & User Guide
THUNDERBAY 4 MINI Assembly Manual & User Guide CONTENTS INTRODUCTION 1.1 Minimum System Requirements...1 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported Drives 1.2 Package Contents...1
More informationAURA SSD FOR MAC PRO. Installation Guide
AURA SSD FOR MAC PRO Installation Guide CONTENTS Introduction... 1 1.1 System Requirements 1.2 Package Contents 1.3 About This Manual Installation... 2 2.1 Preparing the Mac Pro 2.2 Installing the Aura
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UID-0808R, UID-0808T, UID-1600,UID-0016R, UID-0016T Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides
More informationipanel CONTROL TECHNOLOGY CORPORATION ipanel Installation Guide and Specifications ipanel Installation Guide
ipanel CONTROL TECHNOLOGY CORPORATION ipanel Installation Guide and Specifications ipanel Installation Guide CONTROL TECHNOLOGY CORPORATION ipanel Installation Guide and Specifications 2003 Control Technology
More informationewon Flexy 2 Serial Ports Ext. Card FLA 3301
Installation Guide IG 016 / Rev. 1.2 FLA 3301 This Installation Guide explains how to install the 2 Serial Ports Extension Card FLA 3301. support.ewon.biz Table of Contents 1. Product Summary... 3 2. Safety,
More informationCA-A480-A Elevator Controller. Reference & Installation Manual
CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................
More informationProficy* HMI-SCADA G ETTING S TARTED. ON THE A PPLE ipad OR i P HONE C LIENT
Proficy* HMI-SCADA G ETTING S TARTED ON THE A PPLE ipad OR i P HONE C LIENT July 2014 Disclaimer of Warranties and Liability The information contained in this manual is believed to be accurate and reliable.
More informationInstallation and Configuration Guide
Installation and Configuration Guide Trademark Notices Comtrol, NS-Link, and DeviceMaster are trademarks of Comtrol Corporation. Microsoft and Windows are registered trademarks of Microsoft Corporation.
More informationUSB Ranger 110/410 User Guide
USB Ranger 110/410 User Guide Featuring ExtremeUSB Technology USB Ranger 110/410 Thank you for purchasing the USB Ranger. Please read this guide thoroughly before installation. This document applies to
More informationComputador Honeywell Thor MV1
Computador Honeywell Thor MV1 Computador veicular Thor VM1 da Honeywell, o computador ideal para empilhadeiras, supera a competição com inovações de design. Na cadeia de suprimentos de hoje, a única constante
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Wide Modules Installation Guide UID-W1616R, UID-W1616T Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Wide Modules Installation Guide UIS-WCB1 Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide as Uni-I/O
More information1111 West 35th Street Chicago, IL Customer Support: (773) UPS SNMPWEBCARD
1111 West 35th Street Chicago, IL 60609 Customer Support: (773) 869-1234 www.tripplite.com UPS SNMPWEBCARD USER S GUIDE FCC Radio/TV Interference Notice The SNMPWEBCARD has been tested and found to comply
More informationPanelView Plus/VersaView CE Terminals and Display Modules
Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3
More informationCoverTitle. Raven XT. Quick Start Guide for AT&T Rev 3.0E
Raven XT Quick Start Guide for AT&T CoverTitle 20070914 Rev 3.0E Activating your Raven XT on AT&T Installing the SIM Configuring the APN Hardware Installation Indicator Lights Optional: Setting up a DUN
More informationThank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!
1170 POS SYSTEM 1170 INSTALLATION GUIDE Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution! This Installation Guide will help you efficiently install the 1170 POS. The document
More informationInstallation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:
Installation- and Operating instructions for CU8880-0010 Ethernet Controller with USB Input Version: 1.4 Date: 2018-04-12 Table of contents Table of contents 1. 2. 3. 4. 5. General instructions 2 Notes
More informationSylphit-Duo DSK-Series. KVM Drawer (with integrated KVM switch)
Sylphit-Duo DSK-Series KVM Drawer (with integrated KVM switch) User Guide Version 1.0 Technology Corporation Rackit Technology Corporation 274 Madison Avenue, New York, NY 10016 Tel: (212) 679-0050 Fax:
More informationGE Intelligent Platforms Programmable Control Products PACSystems* RX3i DNP3 Slave Module IC695EDS001. Quick Start Guide GFK-2912 October 2014
GE Intelligent Platforms Programmable Control Products PACSystems* RX3i DNP3 Slave Module IC695EDS001 Quick Start Guide GFK-2912 October 2014 g Contents 1. User Features...1 1.1. Overview... 1 1.2. Restart
More informationewon Flexy PSTN Extension Card FLA 3501
Installation Guide IG 021 / Rev. 1.2 FLA 3501 This installation guide explains how to install the FLA 3501. support.ewon.biz Table of Contents 1. Product Summary... 3 2. Safety, Environmental & Regulatory
More informationInfosystem Remote Touchscreen Installation Instructions
Infosystem Remote Touchscreen Installation Instructions DOC. #569102100 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements
More informationINTRODUCTION...1 FEATURES...1 PACKAGE CONTENTS... 1 TECHNICAL SPECIFICATIONS...2 SYSTEM REQUIREMENT..3 CABLE DIAGRAMS.3 PRODUCT DETAILS 4
TABLE OF CONTENTS INTRODUCTION...1 FEATURES....1 PACKAGE CONTENTS... 1 TECHNICAL SPECIFICATIONS....2 SYSTEM REQUIREMENT..3 CABLE DIAGRAMS.3 PRODUCT DETAILS 4 HARDWARE INSTALLATION 5 USAGE 5 ON SCREEN DISPLAY
More informationInstallation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.
Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable
More informationQTERM -A7 TERMINAL HARDWARE MANUAL
QTERM -A7 TERMINAL HARDWARE MANUAL BEIJER ELECTRONICS 2212 South West Temple #50 Salt Lake City, Utah 84115-2648 USA M01-048-00 Rev 02 Phone 801-466-8770 Fax 801-466-8792 Email info@beijerelectronicsinc.com
More informationPart No. P May 4, Business Communications Manager. BCM Imaging Tool User Guide
Part No. P0609711 01.01 May 4, 2004 Business Communications Manager BCM Imaging Tool User Guide 2 Copyright 2004 Nortel Networks All rights reserved. May 4, 2004. The information in this document is subject
More informationTOUCH CONTROLLER CUWIN
TOUCH CONTROLLER CUWIN User Manual 1 1.0 Introduction The CUWIN combines a graphic display and touch interface with a high efficiency industrial controller. It is equipped with Microsoft Windows CE 5.0
More informationSMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)
SMM Series 3G and GSM Modems Quick Start Guide Document Number: 0013-001-000272 () Documentation Control Generation Date: October 20, 2015 Cybertec Pty Limited All rights Reserved. No part of this publication
More informationTHUNDERBAY 4. Assembly Manual & User Guide
THUNDERBAY 4 Assembly Manual & User Guide TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported Drives: up to four 3.5 SATA
More informationGateway Module Programmable in C
User Manual for the HE660CGMx24 Gateway Module Programmable in C Second Edition 09 August 2000 MAN0025-02 MAN0025-02 09 AUG 2000 PAGE 3 PREFACE This manual explains how to use the Horner APG Gateway Module
More informationUSP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10
UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for
More informationC9900-P223 and C9900-P224
Installation and Operating instructions for C9900-P223 and C9900-P224 Power Supply Units Version: 1.2 Date: 2012-02-22 Table of contents Table of contents 1. Foreword 2 Notes on the Documentation 2 Liability
More informationIndustrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide
Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.
More informationAREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.
AREA CODE CHANGE Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727. For any Paradyne telephone number that appears in this manual with an 813 area code,
More informationControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet
General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.
More informationDatapanel. Datapanel 40/45, 60/65 & 85. Operator Interface Products. User's Manual
Datapanel Operator Interface Products Datapanel 40/45, 60/65 & 85 User's Manual GFK-1806A Nov. 2001 Warnings, Cautions, and Notes as Used in this Publication Warning Warning notices are used in this publication
More informationQuick Start Manual. Color Image Scanner
Color Image Scanner EN All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying,
More informationOpen Applications Interface (OAI) Installation and Setup
Open Applications Interface (OAI) Installation and Setup Link Wireless Telephone System Link 3000 MCU Part Number: 72-0059-07 Issue A NOTICE SpectraLink Corporation has prepared this document for use by
More informationThis Datasheet is for the IC754CSL06MTD. The IC754CSL06MTD for the GE QuickPanel has 6 IN MONOCHROME TOUCHSCREEN
This Datasheet is for the IC754CSL06MTD The IC754CSL06MTD for the GE QuickPanel has 6 IN MONOCHROME TOUCHSCREEN http://www.qualitrol.com/shop/p-16499-ic754csl06mtd.aspx For further information, please
More informationTrademarks and registered trademarks are proprietary to their respective manufactures.
Limitation of Liability - Information presented by RATOC in this manual is believed to be accurate and reliable. RATOC assumes no responsibility for its use. No license is granted by implication or otherwise
More informationewon Flexy PSTN Extension Card FLA P3501 Installation Guide
ewon Installation Guide IG 021 / Rev 1.0 ewon Flexy PSTN Extension Card FLA P3501 Contents Installation Guide This installation guide explains how to install the ewon Flexy PSTN Extension Card FLA 3501.
More informationManual Version: V1.00. Video Decoder Quick Guide
Manual Version: V1.00 Video Decoder Quick Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang
More informationAT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A
AT-6102 IEEE 802.3af Universal Multi-voltage PoE Splitter Installation and User Guide PN 613-000635 Rev A Electrical Safety and Emissions Standards Standards: This product meets the following standards.
More informationE600 VX01 Installation guide
E600 VX01 Installation guide illuminfx Dimensions 2007 Viso Systems ApS, Denmark All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing
More informationIO-AO6X I/O Expansion Module 6 Isolated Analog Outputs
IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated
More informationMultiModem rcell. Intelligent Wireless Router. Quick Start Guide
MultiModem rcell Intelligent Wireless Router Quick Start Guide Copyright and Technical Support Quick Start Guide MultiModem rcell MTCBA-Xx-EN2 82100400L, Revision A Copyright 2009 by Multi-Tech Systems,
More informationMiniModules. Reference Manual. Series R CT 3002 V 1.0 MiniModule USB Service Adapter and Software
Reference Manual R CT 3002 V 1.0 MiniModule USB Service Adapter and Software Series 3000 MiniModules LYNX Technik AG Brunnenweg 3 64331 Weiterstadt Germany www.lynx-technik.com Information in this document
More informationELETICS Quickstart Installation Manual
ELETICS Quickstart Installation Manual Version 2.1 April 22 2016 www.teletics.com 1 Statement of Conformity FCC Class A Notice This device complies with Part 15 of the FCC Rules. Operation is subject to
More informationREAD ME FIRST Windows 95/98/Me/2000
READ ME FIRST Windows 95/98/Me/2000 *DSL Equipment Installation Guide: Efficient Networks 5260 *Digital Subscriber Line Part Number: 52609x02 Version 1.2-A Table of Contents Follow Steps 1 through 8 to
More informationPROMISE ARRAY MANAGEMENT ( PAM) USER MANUAL
PROMISE ARRAY MANAGEMENT ( PAM) USER MANUAL Copyright 2002, Promise Technology, Inc. Copyright by Promise Technology, Inc. (Promise Technology). No part of this manual may be reproduced or transmitted
More informationOWC Mercury Pro Optical ASSEMBLY MANUAL & USER GUIDE
OWC Mercury Pro Optical ASSEMBLY MANUAL & USER GUIDE Copyright 2015 Other World Computing All Rights Reserved. Other World Computing s Limited Warranty is not transferable and subject to limitations. TABLE
More informationInstallation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1.
Document Number: 466-1632 Rev. B September 2000 Product Summary The ITI SuperBus 2000 2 x 20 LCD (liquid crystal display) Alphanumeric Touchpad gives you complete on-site system programming and operation
More information6222 Two Door Module Technical Operations Manual
6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5
More informationViewPoint II Operator Interface
ViewPoint II Operator Interface Installation and Setup Manual ViewPoint II Front View (full scale) Industrial Control Links, Inc. 12840 Earhart Ave. Auburn, CA 95602 www.iclinks.com 530-888-1800 ViewPoint
More information2100 POS System User Guide
2100 POS System 2100 User Guide Thank you for selecting UTC RETAIL s innovative Model 2100 Point of Sale solution! This guide is designed to acquaint you with the features and functionality of the 2100
More informationBD FACSMelody Cell Sorter Installation and Security Guide
BD FACSMelody Cell Sorter Installation and Security Guide For Research Use Only 23-20312-00 6/2018 Becton, Dickinson and Company BD Biosciences 2350 Qume Drive San Jose, CA 95131 USA BD Biosciences European
More informationUser s Manual. Version September 2011 Impatica Inc.
Version 1.1.7 September 2011 Impatica Inc. Legal Notice Copyright 2011 Impatica Inc. All rights reserved. The contents of this manual and associated Impatica software are the property of Impatica Inc.
More informationMGate 5111 Quick Installation Guide
MGate 5111 Quick Installation Guide Edition 1.0, December 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778
More informationEnerSure Installation Guide
EnerSure Installation Guide Danger!!! The electrical components of this system may contain voltage and /or amperage sufficient to injure or kill. Installation is only to be performed by a licensed, bonded
More information