HyQuest Solutions Pty Ltd INSTRUCTION MANUAL RAINFALL SENTRY MODEL RS3
|
|
- Bryan Scott
- 5 years ago
- Views:
Transcription
1 INSTRUCTION MANUAL RAINFALL SENTRY MODEL RS3 QUALITY SYSTEM ISO: 9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD Scrivener St, Warwick Farm, NSW 2170, AUSTRALIA Phone: Fax: sales@hyquestsolutions.com.au Web: 1
2 TABLE OF CONTENTS 1. INTRODUCTION SPECIFICATIONS INSTALLATION CONFIGURING / OPERATION
3 1. INTRODUCTION The HyQuest Solutions Rainfall Sentry model RS3 is a low power, microprocessor controlled device designed to monitor rainfall and operate external pumps and/or solenoid valves to control the discharge of storm water into a sewage system. It detects pulses from a Tipping Bucket Rain Gauge, and when a set number of tips have been detected within a selected time period, a relay is operated to control a pump. Another settable timer determines how long the relay is held on for. If pulses from the TBRG are detected while the relay is activated, then the relay hold timer is restarted. 2. SPECIFICATIONS Programmable Settings: Tipping bucket size (0.2mm, 0.5mm, 1.0mm, 0.01 ) Rainfall required to trigger operation (1mm to 20mm) (0.01 to 0.5 ) Rainfall Period (1hr to 24 hrs) Relay hold time (1hr to 24 hrs) Power Requirements: Input: 6V DC (to power internal relay only) Tipping Bucket Rain Gauge (TBRG) Output Relay: 2 x Voltage Free contacts rated at 30V DC 0.5A 3
4 3. INSTALLATION *** Please Note *** The RS3 must be powered by a 6V DC supply. The relay contact outputs are voltage free and rated at 30V DC 0.5A. If operating a mains powered pump, the user must supply a separate slave relay/contactor. The RS3 does not have an IP rating, so a weatherproof enclosure may be required. 4
5 4. CONFIGURING / OPERATION There are 8 LCD screens available for status and configuring the RS3. The screens can be stepped through by pressing the Scroll button. The Select button is used to change a configurable option (display flashes) then press Scroll to change the option and press Select again to save the selection and stop the option flashing. Press any button to switch on the LCD screen. The LCD will turn off automatically after 15 seconds. LCD Display RSentry3 Rev 1.1 Battery OK 0.2mm 00:15 Reset No Bucket 0.2mm RainTrip 1.6 mm RainTime 1 hr HoldTime 1 hr Description Displays the model and software revision Displays the internal 3.6V lithium battery condition as OK or Low (This battery powers the clock/timer) Replace the battery when Low Displays the rainfall in the last hh:mm if triggered, then it displays Trig d if retriggered by further bucket tips then it displays Retrig d Allows the operation to be reset. (same as powering the unit off then on) Press Select to change the No to a Yes Displays the TBRG bucket size as 0.2mm / 0.5mm / 1.0mm / 0.01in Press Select to change the bucket size to match your TBRG Displays the amount of rainfall required to trip the relay. Press Select to change the rainfall required. (1.0mm to 20.0mm) or (0.01in to 0.50in) Displays the period of time in which to measure the rainfall to trip the relay. Press Select to change the time period. (1hr to 24 hrs) Displays the period of time the relay will be closed for. Press Select to change the time period. (1hr to 24 hrs) If the RainTrip amount of rain falls within the RainTime period, then the relay will be triggered. After the relay is triggered and the HoldTime timer starts, any extra bucket tip detected will restart the HoldTime timer that keeps the relay activated. The operation can be Reset at any time by scrolling to the Reset menu and selecting Yes. The operation is shown diagrammatically on the following page. 5
6 This example has the following setup : Bucket is set to say 0.2mm RainTrip is set to say 1.0mm RainTime period is set to say 1 hr HoldTime is set to say 3 hrs which means 5 bucket tips in 1 hour will trip the relay operation, and a bucket tip within the next 3 hours will restart the relay timer. Relay State Off HoldTime period On Tips RainTime period Timer starts when the first tip occurs Timer expired and did not have 5 tips in period Timer starts again 5 tips within the timer period so relay turns on. Timer starts again for each bucket tip while relay is on. HoldTime period expired since no more tips occurred. Sequence starts again when the first tip occurs When a rain gauge tip input is detected, the timer is started. If no further tips occur within the timer period then the unit re-enters the reset state. If however, the selected number of tips occur within the time period then the relay is turned on. Once the relay is operated, each tip will restart the timer, whilst maintaining the on state of the relay. If no further tips occur and the timer expires, the relay is turned off and the timer enters the reset state. 6
OPERATING MANUAL CMC20A Current Meter Counter
OPERATING MANUAL CMC20A Current Meter Counter QUALITY SYSTEM ISO: 9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD 48-50 Scrivener St, Warwick Farm, NSW 2170, AUSTRALIA Phone: +61 2 9601 2022 Fax: +61 2 9602 6971
More informationHyQuest Solutions Pty Ltd. INSTRUCTION MANUAL FCD_App (TBRG FIELD CALIBRATION APPLICATION)
INSTRUCTION MANUAL FCD_App (TBRG FIELD CALIBRATION APPLICATION) QUALITY SYSTEM ISO: 9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD 48-50 Scrivener St, Warwick Farm, NSW 2170, AUSTRALIA Phone: +61 2 9601 2022
More informationPTR4-SP Controller User Manual
PTR4-SP Controller User Manual Thank you for using this product of our company. The PTR4-SP controller can be set 99 groups time (steps), each step the relay switch state can be set switch ON/OFF (closed
More informationINSTRUCTION MANUAL BUBBLER LEVEL SENSOR Model HS30V
INSTRUCTION MANUAL BUBBLER LEVEL SENSOR Model HS30V QUALITY SYSTEM ISO: 9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD 48-50 Scrivener St, Warwick Farm, NSW 2170, AUSTRALIA Phone: +61 2 9601 2022 Fax: +61 2
More informationINSTRUCTION MANUAL ABSOLUTE SHAFT ENCODER MODEL AD375MA
INSTRUCTION MANUAL ABSOLUTE SHAFT ENCODER MODEL AD375MA QUALITY SYSTEM ISO:9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA Phone:(Int.) 612 9601 2022 Fax: :(Int.)
More informationBasic User and Installation Manual
HERON ELECTRIC COMPANY LTD Basic User and Installation Manual Mi-4 Mi-8 Mi-12 Mi-16 Mi-144 Multi -Wire Controller Doc ref. Mi Multi Wire Basic November 2008 TABLE OF CONTENTS 1. About This Controller...
More informationph Meter & Controller Model: NANO-PCD1
Instruction Manual ph Meter & Controller Model: NANO-PCD1 Supplied by: Convergent Water Controls Pty Ltd 2/4 Huntley Street, PO Box 7058 Alexandria NSW 2015 Tel: (02) 9698 3131 www.cwc.com.au Fax: (02)
More informationCT1 Series 2. General Purpose Timer. Installation Manual 1 st Edition
CT1 Series 2 General Purpose Timer Installation Manual 1 st Edition FEATURES 4 Timing Ranges: - 1 to 127 seconds in 1 second increments. - 10 seconds to 21 minutes in 10 second increments. - 1 to 127 minutes
More informationWireless Irrigation Control System
Wireless Irrigation Control System General introduction: Automated irrigation becomes a trend with the development of smart agriculture. In order to send appropriate amount water in proper time to your
More informationDUAL OUTLET CO2002 DIGITAL TAP TIMER INSTRUCTION MANUAL. CO2002 Dual Outlet Digital Tap Timer Instructions.indd 1
DUAL OUTLET DIGITAL TAP TIMER CO2002 INSTRUCTION MANUAL CO2002 Dual Outlet Digital Tap Timer Instructions.indd 1 Table of Contents General Information Display Glossary Operation: AUTO Mode WATERING Mode
More informationicon Series Controls
icon Series Controls icon Series Controls Introducing the Bianco icon range of intelligent controllers. The icon range of intelligent controllers are suitable for installation in various Industrial and
More informationTR-3000 STORM WATER SAMPLER MANUAL OF OPERATION.
TR-3000 STORM WATER SAMPLER MANUAL OF OPERATION www.durhamgeo.com Fax: 770-465-7447 770-465-7557 1-800-837-0864 DESCRIPTION The Durham Geo TR-3000 Storm Water Sampler is designed to monitor rainfall precipitation
More informationMicro-Master Touch Release Notes
Micro-Master Touch Release Notes 1 Micro-Master Touch Release 1.7 1 2 Version Information 1 2.1 Current... Released Versions 1 3 Front Panel 1 3.1 3.1.1 3.1.2 3.1.2.1 3.1.3 3.1.3.1 3.1.3.2 3.1.3.3 3.1.3.4
More informationWARNING. TTDJ Series Fully-Configurable Fault Annunciator Installation and Operations Manual
TTDJ Series Fully-Configurable Fault Annunciator Installation and Operations Manual TTDJ-99062N Revised 04-04 Section 50 (00-02-0412) Please read the following information before installing. This installation
More information24/7 Sprinkler Monitor. The Ultimate Rain/Freeze Sensor
24/7 Sprinkler Monitor The Ultimate Rain/Freeze Sensor User s Manual PIONEER SALES, LTD. 5529 Redfield St. Dallas, TX 75235 Phone: (214) 276-0306 Fax: (214) 631-4218 Toll Free: 1-(866) 501-7745 1 Table
More informationChallenger Version 8 Programming Macro Logic.
Challenger Version 8 Programming Macro Logic. This document provides details of the requirements for planning and programming Macro Logic in a Version 8 Challenger System for use in Alarm Control and/or
More information2.4GHz Digital Wireless 7 LCD Surveillance Kit
2.4GHz Digital Wireless 7 LCD Surveillance Kit User Manual QC-3762 Box Contents: 1 x 7 LCD Monitor 1 x Wireless Camera 2 x Mains Power Adaptors 1 x Camera Antenna 1 x Mounting Hardware Product Diagram:
More informationSeries B9 and C9 Electronic Metering Pumps. Instruction Manual. Manual No : 1796 Rev. : D Rev. Date : 11/2015
Series B9 and C9 Electronic Metering Pumps Manual No : 1796 Rev. : D Rev. Date : 11/2015 sales@novatech-usa.com www.novatech-usa.com Tel: (866) 433-6682 Fax: (866) 433-6684 Tel: (281) 359-8538 Fax: (281)
More informationBIC 100 BERMAD Irrigation Control System
BIC 100 BERMAD Irrigation Control System BIC 100 PROGRAMA 1234567 1 2 1 2 13:47 H:M MV M Operation Manual BERMAD Water Control Solutions Contents Page 1. General Description 03 2. Normal Mode Defining
More informationHyQuest Solutions Pty Ltd. INSTRUCTION MANUAL HS-HartBeat and HS-HartBeat Plus MODEL: HBT1 and HBT1 Plus
INSTRUCTION MANUAL HS-HartBeat and HS-HartBeat Plus MODEL: HBT1 and HBT1 Plus Model: HBT1 Hart to SDI-12 / Modbus Interface Model: HBT1 Plus Hart to SDI-12 / 4-20mA / LCD Interface QUALITY SYSTEM ISO:
More informationDigital 2.4GHz 3.5 LCD Monitor
Digital 2.4GHz 3.5 LCD Monitor QC-3402 User Manual Specifications: 3.5 LCD Monitor Power Consumption: Frame Rate: Run Time: Input Voltage: Dimensions: 400mA 25fps 4 hours continuous 5VDC @ 1A 84(W) x 126(H)
More informationSS2200 Remote Controller
SS2200 Remote Controller General Purpose, DC Voltage General The SS2200 Remote Controller is a microprocessor-based programmable controller specifically designed to control single line and dual line centralized
More informationInstallation & Operation and Maintenance
Gas Safety Products Dual Current Monitor Installation & Operation and Maintenance Read these instructions carefully before operating or servicing Rev: 01 Date: 12-02-18 1 CONTENTS Chapter Content Page
More informationHydrological Services CMC20A OPERATING MANUAL CMC20A. Current Meter Counter
OPERATING MANUAL CMC20A Current Meter Counter 28-Oct-2005 Issue 1.1 CMC20A 100-01 Hydrological Services P/L TABLE OF CONTENTS 1. SPECIFICATIONS... 3 2. INTRODUCTION... 4 3. SPECIFIC FEATURES... 4 4. PANEL
More informationInstruction Manual. BMS CARD Model: DP-OPT-CARD-OP. Supplied by: - Retrofit to (or supplied with) DIGICHEM Plus + Controllers
Instruction Manual BMS CARD Model: DP-OPT-CARD-OP - Retrofit to (or supplied with) DIGICHEM Plus + Controllers - 4-20mA Outputs - NPN Open Collector Status Outputs for Power Failure, Flow, Alarm & Individual
More informationWaste Water Collection System Wireless Monitoring Solutions
Waste Water Collection System Wireless Monitoring Solutions SSO Lift Station Rainfall Flow Meters Ground Water Flap Gate Pressure Relief Valve CSO Flow with A/V Sensor Waste Water Collection Monitoring
More informationABSOLUTE SHAFT ENCODER MODEL AD375MA INSTRUCTION MANUAL
ABSOLUTE SHAFT ENCODER MODEL AD375MA INSTRUCTION MANUAL HYDROLOGICAL SERVICES Pty Ltd 48-50 Scrivener Street Liverpool NSW 2170 Australia Ph. 61 2 9601 2022 Fax. 61 2 9602 6971 E-Mail: sales@hydrologicalservices.com
More informationWeatherMation LIVE Alerts and Notifications Module
WeatherMation LIVE Alerts and Notifications Module Version 1.6.3 28/03/2017 Environdata Australia Pty Ltd 42-44 Percy Street Warwick Queensland 4370 Australia Phone: (07) 4661 4699 Fax: (07) 4661 2485
More informationTwo Door Controller GEN-045
Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify
More informationM2500 Engine Controller Configuration Manual
M2500 Engine Controller Configuration Manual Revision: 08-04-2011 Page 1 Contents 1 Preface... 4 2 Configuration from front panel... 5 2.1 Engine Controller Configuration... 6 2.1.1 RPM settings... 6 2.1.2
More informationOperating Manual. A 1717 Message Player IMPORTANT NOTE: Redback Proudly Made In Australia
www.altronics.com.au Operating Manual A 1717 Message Player Distributed by Altronic Distributors Pty. Ltd. Phone: 1300 780 999 Fax: 1300 790 999 Internet: www.altronics.com.au IMPORTANT NOTE: Please read
More informationINSTALLATION & OPERATION
INSTALLATION & OPERATION MANUAL FOR MultiTrode Indicator Controller (MTIC) & MultiTrode Remote Indicator Controller (MTRIC) MTIC - Indicator Controller MTRIC - Remote Indicator Controller Version 598 MTIC
More informationControl Indicator Module (CIM) - DNP3 Communications Protocol - TECHNICAL MANUAL
Control Indicator Module (CIM) - DNP3 Communications Protocol - TECHNICAL MANUAL Page 1 of 35 Introduction...4 Basic Operation...5 Front Panel Controls and Indicators...5 Real Time Clock Battery Back Up...7
More informationLow Power Modbus GPRS Data Logger
Low Power Modbus GPRS Data Logger Low Power Data Logger suppor ng sleep mode Con nuous opera on for 5 years with internal ba ery Upload Data via GPRS and SMS on schedule Programmable data logging and upload
More informationMini Agg 1-10 (DC/AC)
TALGIL Computing & Control Ltd. ISRAEL TALGIL COMPUTING & CONTROL LTD. NAAMAN CENTER, HAIFA - ACCO ROAD 7000 P.O.BOX 775 KIRYAT MOTZKIN 26119, ISRAEL TEL: 972-4-8775947; 972-4-8775948 FAX: 972-4-8775949
More informationx x 60 mm, 700 gm. Wall mounted enclosure, 1 Kg. Weatherproof, high impact GF ABS. Remote control and monitoring with debug features
Smart Hub Intelligent Energy Management and IoT Hub Unit (CT200i) General Dimension and weight 202.73 x 267.45 x 60 mm, 700 gm Dimension with standard cover 268 x 204 x 56 mm Dimension with weatherproof
More informationUniversal Trigger Box Users Guide
Universal Trigger Box Users Guide Introduction The universal trigger box is intended for use on marine survey vessels as a mean to synchronise multiple acoustic systems in order to reduce or eliminate
More informationReyrolle Protection Devices. 7SG117 Argus 7 Synchronising Relay. Answers for energy
Reyrolle Protection Devices 7SG117 Argus 7 Synchronising Relay Answers for energy 7SG117 Argus 7 Synchronising Relay Fig 1. Independent check & system synchronising settings Adjustable slip frequency,
More informationINPUTS: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)
INPUTS: All inputs: Inputs 1 to 24: Tamper: Panic: Fire: Keyswitch: 16-18VAC: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)
More informationP9 ASD Simple Start Guide
P9 ASD Simple Start Guide Document Number: 64056-002 Date: June, 2011 P9 ASD Simple Start Guide P9 Programming Using the EOI The operating parameters displayed on the LCD screen may be selected, viewed,
More informationManual. NanoTron Dual Timer. Installation Maintenance Repair Manual
Manual NanoTron Dual Timer Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com email: support@advantagecontrols.com
More informationDATA ACQUISITION Hints and Tips
How to use the SquirrelView software with the SQ2010/SQ2020/SQ2040 Data Loggers. SquirrelView Help Page 2 Connecting Your Squirrel Data Logger Page 2 Logger Set-up Page 3 Download Data Page 8 Export Data
More informationProduct User Guide. OctProcessV2 and QuadProcessV2. QuadProcessV2-3A 4-Channel Low Level DC Current
OctProcessV2-3A 8-Channel Low Level DC Current OctProcessV2-30mA 8-Channel Low Level DC Current OctProcessV2-160mA 8-Channel Low Level DC Current QuadProcessV2-3A 4-Channel Low Level DC Current QuadProcessV2-30mA
More informationAN004 Using the PMDX-126 s Error Input and Restart Output with Geckodrive Servo Drivers and Mach3 CNC Software
1.0 Overview This application note describes how to connect the to the Geckodrive G320//G340 step servo driver s ERR/RST terminal to allow the to detect a Geckodrive error (fault) state and to reset the
More information2T105. Multi Range Digital Setting Time Delay Relay. Features. Application. Operation
2T15 Multi Range Digital Setting Time Delay Relay Technical Bulletin Features Four time ranges -.99s, -9.9s, -99s, -99s High accuracy & repeatability timing compensated for output relay delay Time settings
More informationWHIRLYBIRD AUTOMATIC WEATHER STATION. Whirlybird Electronics Pvt Ltd 140, 2 nd Cross 13 th Main, BTM-I Bangalore
WHIRLYBIRD AUTOMATIC WEATHER STATION Whirlybird Electronics Pvt Ltd 140, 2 nd Cross 13 th Main, BTM-I Bangalore 560029 WHIRLYBIRD WWS-A is an Automatic weather station you can count on for reliable and
More informationProduct Data Sheet. BMS/Graphics Interface. Features
BMS/Graphics Interface Product Data Sheet Features The Mxp-010 interface allows BMS systems and graphics PCs to be integrated with the Mx- 4000 series of Fire Control Panels and Remote Terminals. The interface
More informationEA-EL 3000, EA-EL9000, EA-EL 9000 HP 400W W ELECTRONIC DC LOADS
EA-EL 3000, EA-EL9000, EA-EL 9000 HP 400W - 7200W ELECTRONIC DC LOADS Power ratings: 0...400W up to 0...7200W Cabinets with higher power upon request Input voltages: 0...80V, 0...160V, 0...400V, 0...750V
More informationIrrigation Control. Quick Start Guide Version 2c. Using Soil Moisture Sensors. Delta-T Devices Ltd
Irrigation Control Using Soil Moisture Sensors Quick Start Guide Version 2c Delta-T Devices Ltd Overview Irrigation Timer GP1 Solenoid Valve Moisture Content Timer control Sensor control Potential benefits
More informationColour Graphic Terminal User Manual. Rev 3.1
Integriti. Colour Graphic Terminal User Manual. 1 Colour Graphic Terminal User Manual. Rev 3.1 2013-2014. Inner Range Pty. Ltd. Part Number: 636000U 2 Integriti. Revision 3.1 June 2014. SYSTEM DETAILS
More informationLED Wall Clock With Calendar and Temperature Display
User Manual LED Wall Clock With Calendar and Temperature Display XC-0239 Specifications: Remote Power: Remote Distance: Mounting holes: Power: Dimensions: 2 x AA Batteries (required) 8m Yes 9VDC Power
More informationMicro-Master 4500 Series Controllers
Micro-Master 4500 Series Controllers Application Micro-Master controller used for horticultural and agricultural applications with Filter Flushing and Chemical Fertiliser Injection Programs 16 and 25 station
More informationOPERATING MANUAL FOR SMIT-301MH STREAM SELECTOR
OPERATING MANUAL FOR SMIT-301MH STREAM SELECTOR Manufactured By: INSTRUMENTATION PVT. LTD. F-4 Memnagar complex, Opp. Petrol Pump Memnagar, Ahmedabad, India-380 052 Phone: +91-79_ 2749 5500/5600 FAX: +91-79-2741
More informationIntegriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL
Revision 2.1 July. 2014 1 Integriti 8 32 Zone LAN Expander Module Kit P/N: 996005PCB&K For Rev. B PCB. INSTALLATION MANUAL Overview The Integriti 8 Zone Expander Module provides an additional 8 Zone inputs,
More informationPEL-3031E Programmable D.C. Electronic Load
ISO-9001 CERTIFIED MANUFACTURER GOOD WILL INSTRUMENT CO., LTD. PEL-3031E Programmable D.C. Electronic Load GW Instek launches new PEL-3000E series programmable single-channel electronic load. In the series,
More informationTS InteliSwitch Digital Time Switch 24VDC/VAC
SPECIFICATIONS InteliSwitch Digital Time Switch 24VDC/VAC Voltages... 24VAC, 24VDC, VAC Half Rectified Current Consumption............................ Max. 15mA DC........................................
More informationModel: 8R5PR. 8 Channel RS485 Relay Xpander. Installation Manual. Product Revisions F/G
Model: 8R5PR 8 Channel RS485 Relay Xpander Installation Manual Product Revisions F/G 12200 Thatcher Court Poway CA 92064 U.S.A. TEL: 619-486-8787 FAX: 619-486-8789 www.jdstechnologies.com 0 Features 8
More informationSetup Instructions. This manual is only valid for A12B Chargers equipped with the following: S2A-225C card with software version P225C0630
La Marche Manufacturing Company www.lamarchemfg.com DNP 3.0 Serial (RS232/RS485) and Ethernet (TCP/IP) or Fiber SCADA Interface for A12B Chargers Option 21P Option 57T Option 57U Setup Instructions This
More informationBearing (Shock Pulse) Condition Analyzer -110
Bearing (Shock Pulse) Condition Analyzer -110 *Direct indication of machine condition in terms of good - reduced - bad. *Mechanical Condition of bearings *Lubrication condition of bearings *Damage severity
More informationMercury 11-10PV Pack / Condenser Controller Installation & User Guide V6 or Higher
PR0334 PR0335 PR0332 PR0333 Mercury 11-10PV Pack / Condenser Controller Installation & User Guide V6 or Higher For Products: - PR0710, PR0711, PR0720, PR0721 Resource Data Management Ltd 80 Johnstone Avenue,
More informationDS-4483 Standard Logger Program Quick Reference For Software Version: 4.06
DS-4483 Standard Logger Program Quick Reference For Software Version: 4.06 Requires Firmware Version: VL/2.17+ Revision History: Version 1.00 02 February 2004 Preliminary release version Version 4.01 21
More informationEach receiver has 4 switched outputs, which, using our one touch easy-learn process can be controlled from any switch on any compatible transmitter.
SABRE Series RUGGED REMOTE CONTROL SYSTEM Features 4 switch relays - 1200W each Up to 4000m Range 12-32Vac/dc and 230Vac supply Completely waterproof ABS enclosure (IP68) All outputs momentary, latching
More informationChallenger Series Administrators Manual
Challenger Series Administrators Manual P/N MAADMN-TS1016 REV 07 ISS 20AUG15 Copyright Trademarks and patents Manufacturer Agency compliance Contact information 2015 UTC Fire & Security Australia Pty Ltd.
More informationCutout size : 138 X 138 mm 1
UF-MATIC LOGIC CONTROLLER Size : 144(Horizontal) X 144(Vertical) X 125(Depth) mm Cutout size : 138 X 138 mm 1 TECHNICAL SPECIFICATIONS: 1) Size 144(H) X 144(V) X 125(D) mm 2) Cutout size 138(H) X 138(V)
More informationSC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:
SC2000 INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: Website: (407) 299-3825 www.mpelectronics.com Operating Program Revision: 12 Revision Date: 8-27-14
More informationDPP601. Portable Programmer Installation Manual. contents
DPP601 Portable Programmer Installation Manual contents Introduction.. 2 Set the Time Clock..... 4 Controls.... 2 Run a Task... 5 Menu..... 2 Enable or Disable an Event.. 5 Menu Map. 3 Recall a Preset....
More informationPK2200 Series. Features. C-Programmable Controller. Specifications Board Size Enclosure Size Operating Temp.
C-Programmable Controller P00 Series The P00 Series of C-programmable controllers is based on the Zilog Z80 microprocessor. The P00 includes digital, serial, and high-current switching interfaces. The
More informationData Transmitter 795. Data sheet
Data Transmitter 795 Data Transmitter 795 is developed for monitoring of water works, sewage plants, pumping stations and other technical installations. Flexible connections and many options for data transmission
More informationFor more detailed instruction, see the KTA-282 user manual. This document is a condensed version; intended as a reference.
For more detailed instruction, see the KTA-282 user manual. This document is a condensed version; intended as a reference. Weather Station Setup Configuring the KTA-282 Connection Description V + Power
More informationAEXX SERIES MULTI-FUNCTION CLOCK/TIMERS
FN:XXMFCT1.DOC AEXX SERIES MULTI-FUNCTION CLOCK/TIMERS AEXX SERIES MULTI-FUNCTION CLOCK/TIMERS REV 04/09/09 DESCRIPTION The AEXX Series of Multi-Function Clock/Timers are available with 1, 2.3, 4, 8, or
More informationReyrolle Protection Devices. 7SG21 DDB20 Multi Range Digital Setting Time Delay Relay. Energy Management
Reyrolle Protection Devices 7SG21 DDB20 Multi Range Digital Setting Time Delay Relay Energy Management 7SG21 DDB20 Digital Time Delay Induction disc reset emulation Replacement of induction disc timing
More informationInstallation Instructions
SPECIFICATIONS InteliSwitch Digital Time Switch 24VDC/VAC Voltages...... 24VDC, 24VAC, 24VAC Half Wave Rectified Current Consumption...................Max. 15mA DC.................................Max.
More informationInterface BL232 with RS232/422/485 MODBUS and 0-10V outputs. Interface BL232
BIT LINE WEATHER INSTRUMENTS Interface BL232 with RS232/422/485 MODBUS and 0-10V outputs Qick and easy setup For domotic and building automation Wide Range power supply For solar and wind farm BIT LINE
More informationPC180 USER MANUAL CHEMICAL MANAGEMENT SYSTEM
PC180 USER MANUAL CHEMICAL MANAGEMENT SYSTEM Approvals: Class I, Division I, Groups C and D; Class I, Zone 0, Ex/AEx ia [ia] IIB Modbus is a trademark of Modicon, Inc. Manual content copyright 2015 Extreme
More informationTouchpad User Guide. National Sales. Product Support. Freecall: Ph:
Touchpad User Guide National Sales Ph: 1300 306 125 sales@ias.net.au Product Support Freecall: 1800 354 434 support@ias.net.au Designed and Manufactured in Australia by: Innovative Air Systems Pty Ltd.
More information629/P32 (X10/P32) PIC CHIP. On - Off Operating Instructions (Revision 2)
629/P32 (X10/P32) PIC CHIP On - Off Operating Instructions (Revision 2) This manual is a living document, therefore it will change when needed to clarify and explain the operation of the 629/P32 (X10/P32)
More informationTable of Contents. Technical Characteristics. Technical Characteristics 5. Parameters 7. User Interface 9. Installation 15. Product Selection 19
Table of Contents Technical Characteristics Technical Characteristics 5 Parameters 7 User Interface 9 Installation 15 Product Selection 19 6 Technical Characteristics AC DC Input Voltage 100 220 VAC ±
More informationRAIN GAUGE TIPPING BUCKET TYPE
30.006 RAIN GAUGE TIPPING BUCKET TYPE Approval Date: 10.05.2010 Version: 2 Purpose The tipping bucket will typically be deployed in remote areas where frequent site visits are not feasible. Conditions
More informationTABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.
DIVERSIFIED HEAT TRANSFER SERIES 700 STEAM GENERATOR CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE AT SIGMACONTROLS.COM SERIES 700 DHT STEAM GENERATOR MANUAL 042514 2 TABLE OF CONTENTS INTRODUCTION.
More informationInstruction Manual. For file reference, please record the following data:
Instruction Manual Series A9, B9, and C9 Electronic Metering Pumps For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement
More informationEZY SWITCH. SMS-8 System Monitor Installation Manual Applicable for firmware version 1.1 or above
EZY SWITCH SMS-8 System Monitor Installation Manual Applicable for firmware version 1.1 or above Table of Contents Outputs 5 Inputs 6 COMMANDS Getting Started Setting Up Initial User 8 Adding a User 9
More informationMicro Instruments price list All pricing excludes 15%
Micro Instruments price list All pricing excludes VAT @ 15% - 2019 Product Description Solar Smart R1 Solar MPPT regulator 12/24V - 20Amp with R2 799.00 5 Way Relay board R360.00 Ethernet + SNMP support
More informationFCU-4 FAN COIL CONTROLLER
FCU-4 FAN COIL CONTROLLER BACnet Enabled Description The FCU-4 is designed to provide complete control of fan coil units. The FCU-4 incorporates all the inputs and outputs to ensure that this advanced
More informationBB5-Lite TECHNICAL MANUAL
BB5-Lite TECHNICAL MANUAL Product Support 1800 354 434 CC - BB5 - LITE LITE with Plug & Play technology www.blackbox.net.au Designed by IAS in Brisbane Made in Australia Product Support 1800 354 434 www.ias.net.au
More informationENVIRORANGER ERS 500 NVIRORANGER ERS 500 USER GUIDE. Instruction Manual PL-600 January Rev. 1.2
ENVIRORANGER ERS 500 USER GUIDE Instruction Manual PL-600 January 2001 33456000 Rev. 1.2 NVIRORANGER ERS 500 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that
More informationOperating Instructions CHARGERY 440B V1.0
Operating Instructions CHARGERY 440B V1.0 Microprocessor controlled high performance Charger / Discharger/ Balancer / Cell Monitor for LiPo & LiFe battery packs. Charge Rate 0.1-4.0A, 35W, for 2-4 LiPo
More informationThe IRC-Setup Software allows you to set the variables of the infrared sensors made by ALCAPLAST.
SENSOR SETTINGS 1. Software Parameters The IRC-Setup Software allows you to set the variables of the infrared sensors made by ALCAPLAST. You will need the proper USB cable to connect to your computer and
More informationSEQUENCER FOR DEDUSTING PLANTS
BB SEQUENCER FOR DEDUSTING PLANTS PLEASE READ THE WHOLE USER MANUAL CAREFULLY BEFORE INSTALLING THE EQUIPMENT 1. ENTER DATAS IN SET MODE 1. Press key C to have access to the function menu F01 F13. 2. Press
More informationSignet 5700 ph/orp Monitor - ORP Instructions
Signet 5700 ph/ Monitor Instructions English *5700.0901* 5700.0901 Rev. K /06 English/ Contents 1. Power Connections. Compatible Electrode/Preamp Wiring. 4 0 ma Current Output Connections 4. Relay Connections
More informationINSTALLATION PROCEDURE FOR THE INNOVEC IPT POWERED PRINTING TOTALISOR
INSTALLATION PROCEDURE FOR THE INNOVEC IPT POWERED PRINTING TOTALISOR Suite 5, 56-6 Chandos Street, St. Leonards NSW 065/PO Box 35 Spit Junction NSW 088 Australia Phone +6 9906 758 www.innovec.com page
More informationPROFESSIONAL WIRELESS WEATHER STATION. Operation Manual - 1 -
PROFESSIONAL WIRELESS WEATHER STATION Operation Manual - 1 - OVERVIEW Outdoor sensor: 1. Wind Vane 2. Wind Speed Sensor 3. Solar panel 4. Battery compartment 5. LED Indicator: light on for 4 seconds during
More informationTouchpad User Guide (Model: C-LCD-122-TL)
MESSAGE LIBRARY Refer to BBP-5 Instal Guide for information on input triggers. The same message may be linked to more than one trigger. ABBREVIATED VERSION DISPLAYED IN SELECTION SCREEN MESSAGE DISPLAYED
More informationEGCP-2. Application Note (Revision NEW, 4/2003) Original Instructions
Application Note 51211 (Revision NEW, 4/2003) Original Instructions EGCP-2 Software Upgrade Kit Instructions for field conversion of EGCP-2 controls: 8406-120 A or B to 8406-120 C 8406-121 A or B to 8406-121
More informationWater Distribution System Wireless Monitoring Solutions
Water Distribution System Wireless Monitoring Solutions Pump Station Aquifer Level Tank Level Reservoir Level Rainfall Mag Meter Flow Hydrant Pressure Water Meter Flow Water Quality Water Hammer Pressure
More informationSE-win User Instructions
Fan-supplied Positive-pressure Breath-responsive Respirator SE-win User Instructions 300346-02 A Nov 2011 Copyright 2011 by The S.E.A. Group 1 TABLE OF CONTENTS ABOUT SE-win... 3 SE-win FUNCTIONALITY...
More informationTECHNICAL MANUAL FOR THE SHAFTENCODER PROGRAMMING TOOL
FM40432 INTERNATIONAL LIFT EQUIPMENT LTD. London Office Midland Office Units 1&2, Highams Park Ind Estate Wanlip Road Larkshall Road Syston London. E4 7HS Leicester, England LE7 1PD Telephone (020) 85279669
More informationModbus. Serial communication and control of Rotork actuators. Established Leaders in Valve Actuation. Electric Actuators and Control Systems
Electric Actuators and Control Systems Established Leaders in Valve Actuation Modbus Serial communication and control of Rotork actuators Publication S117E Issue 04/09 Rotork actuators have been in use
More informationIsolation Verification Control Mining - Marine - Transit Solutions LIVE Distributed By Locksafe Industrial Safety Equipment
Isolation Verification Control Mining - Marine - Transit Solutions LIVE Isolation Verification Control- Operational Features Part No- LSLIVC www.lingona.com.au The LSLIVC Isolation Verification control
More informationR & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.
R & D SPECIALTIES 2004, by R & D Specialties, Inc. All Rights Reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written permission of R & D Specialties.
More informationDPR-34+ GB Revision 2
DPR-34+ GB Revision 2 1. 2. 3. 4. 5. 6. 7. 8. 9. Important Safety Instructions Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions. Do not use this apparatus near
More information