Seagate Tape Diagnostic Version 2.0 User Guide

Size: px
Start display at page:

Download "Seagate Tape Diagnostic Version 2.0 User Guide"

Transcription

1 Seagate Tape Diagnostic Version 2.0 User Guide Introduction Installation Operating locally on a Windows machine Tape tests Remote operation Command line operation Security considerations 1. INTRODUCTION The Seagate Tape Diagnostic Utility provides basic diagnostic test capabilities, firmware upgrade and, for some tape drives, advanced analysis and configuration. It can be run locally on a single machine or remotely with either a graphical user interface (GUI) or command-line interface. Installation is accomplished simply by copying the application files to the hard drive, in order to minimize the impact on the host machine. The host computer need not be rebooted in order to run the software, and the program can be removed simply by deleting the files. No changes are made to the Registry or other system files. Supported operating systems Windows 98, Windows Me, Windows NT 4.0 and Windows 2000/XP Red Hat Linux 6.2 and 7.0 or equivalent Solaris 2.5, 7 and 8 NetWare 4 and 5 Local operation: Windows: GUI or command-line interface Linux: Command-line interface Solaris: Command-line interface Netware: Command-line interface Remote operation: A client on any platform can communicate with a server on any platform Client Windows: GUI or command-line Linux: Command-line Solaris: Command-line Netware: Command-line Server Windows Linux Solaris Netware Supported tape drives Seagate Scorpion 24/96 (DDS-3) Seagate Scorpion 40/240 (DDS-4) Seagate Viper 200 (LTO) Seagate Travan 8/20 (TR-4/TR-5) and NS 8/20 Other requirements TCP/IP services installed and running 1

2 2. INSTALLATION Installation of the software is very simple: basically, unzip the files from the self-extracting executable, then run the application. For installation procedures on each operating system, see Appendix A. 3. WINDOWS OPERATION ON A LOCAL MACHINE For remote client/server operation, see Appendix B. For command-line or batch file operation, see Appendix C. Launch the software To run the diagnostic, double-click on the desktop shortcut (if you placed one) or open Explorer, go to the directory in which you unzipped the application files and double-click on stdiag.exe. The following dialog will be displayed: Assuming the tape drive(s) is directly attached to the local machine on which you are running the diagnostic, make sure Local Tape Drive(s) is selected and click OK. The software will search for all the supported tape drives that are attached to the system. (In the case of Windows 98, it will take a few moments to find attached SCSI drives.) Once the search is complete, the diagnostic window will be displayed, showing one tab for each supported tape drive found. Included are the drive type and serial number (on the tab), SCSI or ATAPI location, drive model number and firmware revision level. Travan 8/20 drives do not display serial numbers. 2

3 Click the tab that represents the tape drive you wish to work on, then select one of the available operations in the left-hand column. The options available in the right-hand column will vary depending on your selection and the type of tape drive being accessed. When a test or operation has been launched, the status, results and error messages will be displayed in the view window, including a date/time stamp and drive details. This information can be saved to disk as a text file by clicking the Save button, then opened and printed from Notepad or another word processor. If you save the view window again using the same file name, the new information will be appended to the previous file. Clicking the Clear button will erase the information displayed in the view window. Trace buffer data (DDS-4 and LTO only) and Viper-specific information (cartridge memory and EEPROM data) will be saved to a binary file on disk instead of being displayed in the view window. To exit the application, click the Exit button or the X in the upper right corner of the window. 3

4 The available operations are as follows (not all operations are available on every drive type): Tape Operation Tests Read-Write Test: The program will write the specified amount of repeating-pattern data on a new or scratch tape (or if no value is specified, 200MB for Viper, 20MB for DAT, 5 MB for Travan), then rewind and read back the data pattern to compare it with the original. The vertical progress bars will show the approximate percentage completed, and an entry will be made in the view window for each action in the test. If the error count does not exceed the acceptable maximum, the drive will be reported as having successfully passed the test. Otherwise, one or more error messages will be displayed in the view window. Compression Test: The program will perform a read-write test, using hardware data compression to confirm that your tape drive s data compression is functioning properly. If no test size is specified, the program will write 200MB. (NOTE: Travan tape drives do not support hardware data compression unless they are in the NS series.) Options: Retension Tape Before Test: This checkbox enables a retension pass (quickly run the tape from beginning to end) before a Read-Write or Compression test. It is highly recommended for Travan drives and optional for Viper drives. Test Size: When using the Read-Write or Compression tests, you can optionally configure the size of the test data set. Enter an integer number in megabytes (there are 1000 megabytes in a gigabyte). If you do not set a size, the data set will automatically be the defaults listed above. The program will not accept any value less than 5 MB. Electronic Test This button will test the drive electronics (the same as the Power On Self-Test) and report a pass/fail status in the view window. Retrieve Information Check the box to select which type of information you want to be retrieved from the drive (on Travan and DDS-3, only log pages can be retrieved). Then click the Retrieve button to download the information. Log Pages: This checkbox enables a text dump of the available log pages from the drive. The information will be displayed in the view window. Trace Buffer: This checkbox enables a dump of the drive s internal trace buffer, showing history of recent operations. This is a binary file and must be saved to disk. Enter the full path and file name where you want this information to be stored. Cartridge Memory: This checkbox enables a dump of LTO cartridge memory from the media currently in a Viper drive. This is a binary file and must be saved to disk. Enter the full path and file name where you want this information to be stored. EEPROM Data: This checkbox enables a dump of a Viper drive s internal EEPROM settings. This is a binary file and must be saved to disk. Enter the full path and file name where you want this information to be stored. Upgrade Firmware Firmware is the binary code stored in the tape drive s permanent memory that controls its basic operation. Firmware revisions are released by Seagate to address specific issues discovered after manufacturing. 4

5 This software is capable of performing firmware upgrades for the following tape drives and corresponding autoloaders: Scorpion 24 DDS-3 DAT drives (firmware version 7xxx)/Scorpion 96 autoloader Scorpion 40 DDS-4 DAT drives (firmware version 8xxx/9xxx)/Scorpion 240 autoloader Viper 200 LTO drives (firmware version Vxxx) (Use separate upgrade utility for Viper 2000 autoloaders) Type in the name of the firmware file, including file extension (such as V img). IMPORTANT: The firmware file must be in the same directory as the diagnostic software application and must have the original name as supplied by Seagate. NOTE: If your Seagate tape drive was purchased as part of a computer system, check with the manufacturer before upgrading firmware. You may have a special version of firmware, and replacing it with a standard Seagate version may cause incompatibilities. View/Change Drive Settings (Viper only) Choose the appropriate Viper drive settings that you want to view or change by clicking the drop down list box next to each function. When you have completed your selections, click the Apply button to display settings (in the view window) and/or update the tape drive. Available functions are: Compression Setting: Sets data compression to Enabled or Disabled via the Data Compression Control Page (0Fh). Compression Control: Sets the default compression mode via the Drive Capabilities Conrol Mode Page (21h), with the possible values of On, Off and SCSI [default]. This must be set to SCSI in order for compression to be controlled via the Compression Setting function. Tape Speed: Sets the maximum drive speed in MB/sec, with the possible values of 16, 14, 12, 10, 8 and Automatic (speed selection via FastSense [default]). Auto Load: Sets the cartridge autoload mode, with the possible values of Off, Hold and On [default]. With off, the cartridge cannot be loaded at all; with hold, the cartridge will seat but will not thread the tape; with on, the cartridge will both seat and load the tape. Perform Manual Operations Click on the button that performs the operation you require. Available functions are: Retension Tape (Travan and Viper only): This launches a retension pass (quickly run the tape from beginning to end) on the media currently inserted into the drive. Park Load Arm (Viper only): This moves the Viper recording head assembly and cartridge carrier into a secure parked position for shipping (IMPORTANT: The media cartridge must be completely removed from the drive before this command is issued, or damage may occur to the drive and cartridge.) Unpark Load Arm (Viper only): This moves the Viper recording head assembly and cartridge carrier back into the ready position. In normal operation, this command is unnecessary, because the Viper drive will automatically unpark on power-up. 5

6 APPENDIX A INSTALLATION Windows 2000/XP: 1. Copy the self-extracting zip file WinDiag.exe to a directory of your choice, such as c:\tapediag. Do not use spaces in the path name. 2. From Windows Explorer, double-click on the executable. It will extract the application files to the same directory (diagsv.exe is the server/standalone module, stdiag.exe is the GUI client and stdiagcl.exe is the remote command-line client module). If you wish, right click on stdiag.exe, make a shortcut and drag it to the Windows desktop. 3. In order to communicate with the tape drives, the native Microsoft tape drivers or Seagate equivalent must be installed and running. The native Microsoft driver in Windows 2000 supports the Seagate DDS-3/DDS-4 DAT drives and Travan 8GB/20GB drives. 4. The URL contains instructions on how to download native applet Windows 2000 tape drivers for the Seagate Viper tape drives. (An exception to this is that users of VERITAS Backup Exec for servers can enable the software drivers to always be active on boot up. The diagnostic will communicate with the tape drives in this instance. Review the help for Device Configuration Wizard. In order for the diagnostic to work, the Backup Exec services must remain stopped.) 5. On Windows 2000, any backup application services must be stopped, or else the diagnostic will not be able to detect the tape drive, since devices cannot be shared. Exiting the application will not always release the application s access to the tape drive. It is also necessary to stop the service from the Device Manager. Windows NT 4.0: 1. Copy the self-extracting zip file WinDiag.exe to a directory of your choice, such as c:\tapediag. Do not use spaces in the path name. 2. From Windows Explorer, double-click on the executable. It will extract the application files to the same directory (diagsv.exe is the server/standalone module, stdiag.exe is the GUI client and stdiagcl.exe is the remote command-line client module). If you wish, right click on stdiag.exe, make a shortcut and drag it to the Windows desktop. 3. Provide access to the tape driver. In order to communicate with the tape drives, the native applet Microsoft tape drivers or Seagate equivalent must be installed and running. Instructions on how to the download native Windows NT tape drivers for the Seagate DDS/DAT and Travan tape drives is available at: Instructions on how to the download native applet Windows NT tape drivers for the Seagate Viper Ultrium tape drive is available at: (An exception to this is that users of VERITAS Backup Exec for servers can enable the software drivers to always be active on boot up. The diagnostic will communicate with the tape drive in this instance. Review the help for Device Configuration Wizard. In order for the diagnostic to work, the Backup Exec services must remain stopped.) 4. Windows NT does not allow sharing of devices. Stop all backup application services or else the diagnostic will not be able to detect the tape drive. Exiting the application will not always release 6

7 the application s access to the tape drive. It is necessary to stop the services from the Control Panel. Windows 98/Me: 1. Copy the self-extracting zip file WinDiag.exe to a directory of your choice, such as c:\tapediag. Do not use spaces in the path name. 2. From Windows Explorer, double-click on the executable. It will extract the application files to the same directory (diagsv.exe is the server/standalone module, stdiag.exe is the GUI client and stdiagcl.exe is the remote command-line client module). If you wish, right click on stdiag.exe, make a shortcut and drag it to the Windows desktop. Linux: 1. Check that the kernel has the SCSI generic driver sg installed. 2. Use the find name sg print command to see if the sg driver exists in the system. 3. Use the command find name sg.o print to see if the sg driver has been compiled into the kernel or as a module. 4. Refer to the systems kernel documentation for more information on obtaining the files if they do not exist in the system. 5. Other helpful information is available at 6. Copy the LnxDiag.zip file to any directory of your choice. Do not use spaces in the path name. 7. The file LnxDiag.zip is in compressed form. Use Extract to unzip the included files (diagsvlx.exe is the server/standalone module and stdiaglx.exe is the remote client module). Note: In order for the remote diagnostic to work correctly, the proper IP address much be included in the /etc/host file. Because of Linux driver limitations, the Viper extended sense codes are not supported. Some of the Linux kernels have a known driver bug that causes SCSI error messages to be displayed to the screen during drive detection. These do not affect operation of the drive nor the diagnostic software and can be ignored. The firmware download option may show a failed status on the console and parity errors. This is due to the sg driver not requesting Synchronous Data Transfer immediately after the download completes. The validity of the firmware download is not affected. If an ATAPI tape drive is not detected under Linux, type the following sequence of commands from the Linux console in order to allow ATAPI tape commands to be sent: rmmod ide-tape [Enter] rmmod ide-scsi [Enter] modprobe ide-scsi [Enter] 7

8 Solaris: 1. Copy the SolDiag.zip file to any directory of your choice. Do not use spaces in the path name. 2. The file SolDiag.zip is in compressed form. Use the unzip command to extract the included files (diagsvsl.exe is the server/standalone module and stdiagsl.exe is the remote client module). Note: ATAPI tape drives are not supported. Netware: 1. Copy the NtwDiag.zip file to any directory of your choice. Do not use spaces in the path name. 2. The file NtwDiag.zip is in compressed form. Use the unzip command to extract the included files (diagsvnw.nlm is the server/standalone module and stdiagnw.nlm is the remote client module). You can run the application on a NetWare server by using any of the following three options: a.) From a client system, copy diagsvnw.nlm into the SYS volume directory. b.) Shut down the server and copy diagsvnw.nlm into the C:\NWSERVER directory. c.) Run diagsvnw.nlm from the floppy drive. Note: The diagnostic uses the ASPI driver, not the application tape driver, to access the tape drive. Unload the tape driver nwtape.cdm if using VERITAS Backup Exec. Observe the following requirements and limitations on the NetWare version: The following modules must be loaded: NWASPI.CDM and CLIB.NLM Always use full path names for firmware and log files. Never use the X:\NWSERVER directory for file access. The log files created by the diagnostic will be placed in the server s SYS directory. Tape reads and writes are limited to 32K by NWASPI, so long read-write tests will not always stream on Viper drives. ATAPI tape drives are not supported. 8

9 For a discussion of security issues, see Appendix D. APPENDIX B REMOTE OPERATION In addition to local operation on a Windows machine, the diagnostic software can operate remotely, using either a Windows GUI client or a command-line interface. A client on any supported platform can communicate with a server on any supported platform (i.e., Windows, Linux, Solaris or Netware). Whether local or remote, the diagnostic application actually consists of two parts: a client and a server. These communicate with each other via TCP/IP sockets. It is important to run the server first, then connect from the client. Step 1: Run the diagnostic server 1. Load the server component on the remote machine (via FTP or other means). You may need to unzip the compressed file set for the particular operating system in order to separate out the server executable. Server executable names are: Windows: diagsv.exe Linux: diagsvlx.exe Solaris: diagsvsl.exe Netware: diagsvnw.nlm 2. Run the server component by typing the following from the command line (local or telnet) or the Start/Run menu: [executable name] server [Enter] (On Windows, you would type: diagsv server) If you want to password-protect access to the server (passwords are case-sensitive!), add the following switch: -pw: [password] If you want the server to listen for a client connection on a TCP/IP port other than the default (8800), add the following switch: -cp: [port number] For example, on Windows you could run the server with the following command: diagsv server pw:mysecret cp: The server will find the supported tape drives attached to the machine on which it is running, then display the following screen when it is ready to receive the client connection: 4. When the client connects, its IP address will be displayed in the window. When the client disconnects, a disconnect message will be displayed. 9

10 5. Make sure a scratch tape is in the drive if doing a read-write or compression test and that the media is removed before doing a firmware upgrade. 6. When you have finished testing, you can end the server session locally by selecting the server window and typing exit or clicking the X in the corner of the window. The server component can also be shut down from the remote client, by clicking on Exit All (Windows GUI client) or typing the shutdown command (command line client). On NetWare servers, the client must be used to close the active diagnostic server NLM. Step 2: Run the diagnostic client A. Windows GUI Client 1. To run the Windows GUI client, double-click on the desktop shortcut (if you placed one) or go to the directory in which you unzipped the application files and double-click on stdiag.exe. The following dialog will be displayed: 2. Click on Remote Tape Drive(s). 3. Enter the IP address of the remote machine to which the tape drive(s) is attached. The diagnostic server component must already be running there (see Step 1). If the server is behind a firewall, prior arrangements must have been made to allow access. (The diagnostic software communicates via TCP/IP sockets and only sends text strings back and forth, as if they were typed from the command line. Only valid diagnostic commands are accepted, so security risks are minimized.) 4. If the server was launched with a password, enter the password into the dialog box. NOTE: Passwords are case-sensitive! 5. If the server was launched to listen on a TCP/IP port other than the default (8800), enter the port number into the dialog box. 10

11 6. Click OK. When the connection is made successfully, the main diagnostic window will be displayed. You may then continue as if the server were local. See Windows Operation above for operating instructions. 7. When you have finished, you can click the Exit button to close the GUI client but leave the remote server running, or click Exit All to shut down both the GUI client and the remote server application. IMPORTANT: When operating remotely, binary files (firmware files, trace buffer data, cartridge memory information and EEPROM data) will be stored on the server. Only view window files (including log page dumps) will be saved on the client machine. When upgrading firmware, you must have the firmware file on the server to which the drive is locally attached. This can be sent via FTP or other means. B. Command-Line Client (Windows, Linux, Solaris or Netware) To run the diagnostic command-line client instead of the Windows graphical client, make sure the server is already running, then launch the client by typing the appropriate command from the console, as follows: <executable> <command> <switch><:value> <path/\logfilename.extension> where <executable> is one of the following: Windows: stdiagcl.exe Linux: stdiaglx.exe Solaris: stdiagsl.exe Netware: stdiagnw.nlm See Appendix C for command-line syntax. The remote command-line client works identically to the local command-line, except for the required IP address and optional additional switches: -ip: [IP address of the server to which you want to connect] If the server was launched with password-protection (passwords are case-sensitive!), add the following switch: -pw: [password] If the server was launched to listen for a client connection on a TCP/IP port other than the default (8800), add the following switch: -cp: [port number] For example, on Windows you could show all supported tape drives attached to the server with the following command: stdiagcl show ip: pw:mysecret cp:6060 When you have finished working with the diagnostic software, you can send the shutdown command to shut down the remote server application. NOTE: Interactive mode is not supported with remote operation. IMPORTANT: When operating remotely, binary files (firmware files, trace buffer data, cartridge memory information and EEPROM data) will be stored on the server. Only view window files (including log page dumps) will be saved on the client machine. When upgrading firmware, you must have the firmware file on the server to which the drive is locally attached. This can be sent via FTP or other means. 11

12 APPENDIX C COMMAND-LINE OPERATION IMPORTANT: Since there is no interactivity when using the command line, it is the user s responsibility to make sure that any media used is a scratch tape and not valuable data that could be overwritten. The diagnostic software can be run via the command line either locally or remotely. Local Operation: To run the software on the machine to which the tape drive(s) is attached, simply run the server executable with the appropriate commands. You have a choice of two modes: Interactive mode: Type the name of the server application without parameters (on Windows, it is diagsv.exe) and press [Enter]. The software will launch, locate all the supported tape drives, and be ready for input of your first command, indicated by a <1>: Type the first command (show in the example above), then press Enter. After the first command is complete, the application will remain running and wait for input of your next command <2>, and so on. When you have finished testing, type exit to close the application. Single command mode: Type the name of the server executable with parameters and press [Enter]. The software will launch, locate all the supported tape drives, and execute the command you have entered. When it has completed the command, the software will exit and return you to the system prompt. A series of these commands can be saved to a batch file and run sequentially. Remote Operation: The diagnostic software can be run remotely from the command line exactly the same way as the GUI version, except that the client interface is a command line rather than a graphical window. See Appendix B for details on starting the server and the command-line client. NOTE: Interactive mode is not available in remote operation. 12

13 Command Line Syntax Syntax is as follows: <executable> <command> <switch><:value> <path/\logfilename.extension> (In Interactive Mode, omit the executable name in your commands.) Note: On Linux/Unix systems, the syntax is case-sensitive Operating Example with parameters* System Windows diagsv rwtest id:6 ts:12 o:c:\tmp\logfile1.txt Linux./diagsvlx rwtest id:6 ts:12 o:/tmp/logfile1.txt Solaris diagsvsl rwtest id:6 ts:12 o:/tmp/logfile1.txt NetWare diagsvnw rwtest id:6 ts:12 o:c:\tmp\logfile1.txt * runs a read-write test on a drive with target ID 6 with a test file size of 12 MB; results are displayed on the screen and also saved to the text file logfile1.txt Basic Commands A summary help screen of the basic commands and switches is available by typing the executable name with no parameters, or with the h parameter, or followed by the word help. If a syntax error occurs, the help file will automatically be displayed. Commands rwtest ctest upgrade logpages enablecomp disablecomp compstatus retension show help trace etest shutdown Tape read-write test sends a repeating data pattern to the tape drive, then reads it back and compares it on the host. This test will use the current block size setting on the drive and adjust the length and error calculations accordingly. The default test size is 200MB for Viper, 20MB for DAT, 5 MB for Travan (no compression). Hardware compression test confirms that hardware data compression is operational on the drive. This test is operationally identical to the read-write test, except that compression is turned on. The default test size is 200 MB (compressed). Upgrade firmware command must be used with the f switch to identify the binary file that contains the new firmware. (Note: On some systems with DDS-3, there may be a conflict between the tape drive and an auto-polling CD-ROM on the same SCSI bus. In this case, turn off the autoplay feature of the CD-ROM while upgrading the tape drive firmware.) Dumps drive log pages in formatted ASCII text. This command should be used with the o switch to direct output to a text file. Sets data compression to Enabled via the Data Compression Control Page (0Fh). Sets data compression to Disabled via the Data Compression Control Page (0Fh). Returns the current data compression setting (Page 0Fh). Retension the media on drives that support the retension command. Shows all of the Seagate drives detected by the application, including model number, SCSI ID, serial number and firmware version. Displays the help screen. Dumps binary trace information. This command must be used with the f switch to direct output to a binary file on disc. Applicable only to Viper and DDS4 drives. (Not available on Viper prior to firmware version 1270.) Internal electronics test. Result is pass or fail. (Viper and DDS-4 drives only) Shuts down the remote server application. 13

14 Basic Switches Target drive identification (use one of the two): -id: = identifies the drive by target (logical) ID. If no duplicate tape IDs exist on the system (which can be determined with the show command), this is sufficient to identify the drive to be tested. The special case -id:x can be used if you want the application to test the first Seagate drive it recognizes. See the read-me file for a list of possible ID syntax. -sn: = drive serial number. (Note: Travan TR4/TR5 do not have serial numbers in firmware.) Text output (use one of the two, otherwise output is to the screen only): -o: = text output file name, with full path recommended. (NOTE: Spaces are not supported.) Provides ASCII text output to a file on disc as well as the screen. Using an existing filename will result in an append to that file. -nov: = no screen output (if followed by a filename, output is just to that text file on disc). General: -ts: = read-write or compression test size in megabytes (default is 200MB for Viper, 20MB for DAT, 5 MB for Travan on read-write or 200 MB for compression unless this switch is used). -f: = binary file name, with full path included. (NOTE: Spaces are not supported.) Used with the upgrade command to specify the firmware file to be loaded and the trace, cmemory and eeprom commands to specify the binary output file. -i = ignore firmware version. Allows a downgrade or a repeat load of the same version. On Viper drives, if only the last four digits of the firmware name have changed, the i switch must be used, since the application only checks against the leading digits. -fr = full retension of media before executing rwtest or ctest (on drives that support the retension command) -nr = suppress the Press enter to continue prompt. Used with batch file operation. Viper-Specific Commands park = moves the Viper recording head assembly and cartridge carrier into a secure parked position for shipping (IMPORTANT: The media cartridge must be completely removed from the drive before this command is issued, or damage may occur to the drive and cartridge.) unpark = moves the Viper recording head assembly and cartridge carrier back into the ready position. In normal operation, this command is unnecessary, because the Viper drive will automatically unpark on power-up. eeprom = retrieves the 8K byte EEPROM buffer from the drive. This command must be used with the f switch to direct output to a binary file on disc. cmemory = retrieves the 4K byte Cartridge Memory data from the cartridge currently inserted in the drive. This command must be used with the o switch to direct output to a text file on disc. Advanced Viper Settings set <switch> = sets one or more of the following Viper virtual switches: -speed:<value> = sets the maximum drive speed in MB/sec, with the possible values of 16, 14, 12, 10, 8 and 0 (0 = automatic speed selection via FastSense [default]). -compdefault:<value> = sets the default compression mode via the Drive Capabilities Conrol Mode Page (21h), with the possible values of on, off and scsi [default]. This must be set to scsi in order for compression to be controlled via the enablecomp/disablecomp commands. -load:<value> = sets the cartridge autoload mode, with the possible values of off, hold and on [default]. With off, the cartridge cannot be loaded at all; with hold, the cartridge will seat but will not thread the tape; with on, the cartridge will both seat and load the tape. get <switch> = gets the current setting of one or more of the following Viper virtual switches: -speed -compdefault -load 14

15 Command-Line Quick Reference ( * = Viper only ) Tests rwtest ctest etest Operations upgrade park* unpark* retension Information Retrieval show trace logpages eeprom* cmemory* Compression Settings enablecomp disablecomp compstatus Switches -id:targetid -sn:serialnumber -o:textfilename and Path -nov:textfilename and Path -ts:testsize -f:binaryfilename and Path -i (ignore firmware version comparison) -fr full retension before test -nr (suppress Press Enter prompt) Viper Settings* set <switches> where switches are: -speed: (0 = auto) -compdefault:scsi on off -load:on hold off get <switches> where switches are: -speed -compdefault -load Sample commands on a Windows system (Assumes the executable is called diagsv and the drive is at SCSI ID 4) Display detail on screen about all Seagate tape drives attached to system: diagsv show Dump drive log pages to screen: diagsv logpages id:4 Dump drive log pages to screen and a text file: diagsv logpages id:4 o:c:\temp\text1.txt Dump drive log pages to a text file only: diagsv logpages id:4 nov:c:\temp\text1.txt Upgrade firmware to version : diagsv upgrade id:4 f:c:\temp\v img Do a read-write test of 20MB, with results to the screen and a text file: diagsv rwtest id:4 ts:20 o:c:\temp\text.txt Retension the tape (if supported by the drive): diagsv retension id:4 Determine hardware compression setting (if supported by the drive): diagsv compstatus id:4 15

16 APPENDIX D SECURITY CONSIDERATIONS FOR REMOTE OPERATION While diagnostic and firmware upgrade operations are handled locally most of the time, this software has been designed to enable remote communication as well. Whether local or remote, the diagnostic application consists of two parts: a client component and a server component. These communicate with each other via TCP/IP sockets. If you are performing remote operations inside an intranet, typically both the client and server machines are within a single firewall, thus minimizing security issues. Only in the case where a client outside the corporate firewall (such as a reseller s technical support staff) is trying to diagnose a tape drive on a server inside the firewall (such as the reseller s customer) will security questions need to be addressed. Companies set up their security based on what is most important to them: convenience or protection. Each installation will vary according to the relative priorities, so the information below is given as a general guideline, to be adapted to a particular situation. The architecture of the diagnostic software is as follows: CLIENT Server Software SERVER Tape Drive Client Software Socket Communication Binary data neither enters nor leaves the server at any time during operation of the diagnostic software. All communication with the tape drive is done locally, between the server software and the drive. The server software must be placed on the server machine either by manual installation (copy it to a directory) or by downloading via File Transfer Protocol (FTP). Similarly, any firmware file used to upgrade the tape drive must reside on the server to which the tape drive is attached, and any binary information extracted from the tape drive (such as a trace buffer capture) will be saved to a user-designated file on the server itself. It is up to the user to move such files on and off the server, either manually or via FTP, etc. The diagnostic s server software must be launched locally (the remote client cannot launch it). The server software first builds a list of the supported tape drives attached to the machine on which it is running. Then it goes into a waiting mode, listening on a designated port (default is 8800) for a specific connect command from the diagnostic client. Any other command, request, data or message is discarded and an error is generated. Once a client connects (and only one connection is allowed at a time), the server will wait for one of several specific commands from the client. The graphical user interface (GUI) client will build commands based on the buttons the user clicks. With the command line client, the user enters the command directly from the keyboard. In either case, the commands sent over the network are simple text strings, for example: upgrade id:4 f:c:\temp\v img Again, no other command, request, data or message can be accepted by the server. When processing commands, the server will send status messages back to the client via the TCP/IP socket. These too are text strings (see the dialog box illustration on page 3 for a sample of status messages). 16

17 When the server receives the SHUTDOWN command from the client, it will close the socket connection and terminate. Setting Up Remote Internet Communication Through a Firewall In general, there are two approaches to setting up remote communication through a firewall in order for the diagnostic to remotely test a tape drive: 1. Virtual Private Network (VPN) connection If a VPN account has been set up and the appropriate software is in place, the client outside the firewall can connect with the diagnostic server component on the machine to which the tape drive is attached simply by connecting to that machine s IP address, as entered by the user. This will work as if both client and server are inside the firewall, such as on a LAN. 2. Standard TCP/IP address or port mapping The client and server machines will need valid external IP addresses, which may need to be added to the other s access list (host allow list). Also, the communication port (either the default port 8800 or a userdesignated port) must be valid and available for Internet communication. Static routing and port access forwarding are two common methods of achieving these results. In the end, the approach you take will be determined by the complexity of the security and the company s willingness to accommodate traffic from outside the firewall. The diagnostic software has been designed to be as small a risk to network security as possible, but ultimately the access decision and implementation are up to the user. The diagnostic includes the following file names: APPENDIX E FILE NAMES Operating System Client Server Installed Zip file Windows stdiag.exe (GUI) diagsv.exe WinDiag.exe (self-extracting) stdiagcl.exe (cmd. Line) Linux stdiaglx.exe diagsvlx.exe LnxDiag.zip Solaris stdiagsl.exe diagsvsl.exe SolDiag.zip Netware stdiagnw.nlm diagsvnw.nlm NtwDiag.zip Note: For local operation, both the client and server must be installed in the same directory. The client will automatically launch the server when using the GUI on a local Windows machine. Otherwise, the server must be started manually before the client is launched. Copyright (c) 2001 by Seagate Removable Storage Solutions LLC. All rights reserved. September

FOR NETWARE. Tested and. Approved

FOR NETWARE. Tested and. Approved 7 v e r s i o n TM FOR NETWARE Tested and Approved Introduction This guide is designed to help you install Backup Exec for NetWare from the Backup Exec Installation CD. It is intended for administrators

More information

PROMISE ARRAY MANAGEMENT ( PAM) USER MANUAL

PROMISE ARRAY MANAGEMENT ( PAM) USER MANUAL PROMISE ARRAY MANAGEMENT ( PAM) USER MANUAL Copyright 2002, Promise Technology, Inc. Copyright by Promise Technology, Inc. (Promise Technology). No part of this manual may be reproduced or transmitted

More information

[7DON 0DQDJHPHQW &RQVROH IRU :LQGRZV

[7DON 0DQDJHPHQW &RQVROH IRU :LQGRZV 81-81610-04 A01 xtalk Management Console for Windows User s Guide, 81-81610-04 Revision A01, September 2007, Made in U.S.A. Quantum Corporation provides this publication as is without warranty of any kind,

More information

Avalanche Remote Control User Guide. Version 4.1

Avalanche Remote Control User Guide. Version 4.1 Avalanche Remote Control User Guide Version 4.1 ii Copyright 2012 by Wavelink Corporation. All rights reserved. Wavelink Corporation 10808 South River Front Parkway, Suite 200 South Jordan, Utah 84095

More information

SERVICE2000 QUICK START

SERVICE2000 QUICK START SERVICE2000 QUICK START Installation Guide for Release 8 Table of Contents Introduction 2 System Requirements 2 Preparation - All Editions 2 Installation - Single User Edition 3 Installation - Network

More information

GIFTePay XML. SecurePay. Installation & Configuration Guide. Version Part Number: (ML) (SL)

GIFTePay XML. SecurePay. Installation & Configuration Guide. Version Part Number: (ML) (SL) GIFTePay XML Installation & Configuration Guide SecurePay Version 4.00 Part Number: 8662.82 (ML) 8662.83 (SL) GIFTePay XML Installation & Configuration Guide Copyright 2009 Datacap Systems Inc. All rights

More information

Software Images. About Software Images. Dependent Factors. Send documentation comments to CHAPTER

Software Images. About Software Images. Dependent Factors. Send documentation comments to CHAPTER CHAPTER 10 This chapter describes how to install and upgrade software images, and introduces the file system. It includes the following sections: About, page 10-1 Essential Upgrade Prerequisites, page

More information

AVWorks. Installer/User Guide

AVWorks. Installer/User Guide AVWorks Installer/User Guide INSTRUCTIONS This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.

More information

IBM NetBAY Virtual Console Software. Installer and User Guide

IBM NetBAY Virtual Console Software. Installer and User Guide IBM NetBAY Virtual Console Software Installer and User Guide INSTRUCTIONS This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the

More information

Installation Guide for Servers

Installation Guide for Servers Client Data System Installation Guide for Servers Copyright 2002, E-Z Data, Inc. E-Z Data, Inc. 918 East Green Street Pasadena, CA 91106 Web: http://www.ez-data.com Telephone: (626) 585-3505 Fax: (626)

More information

Lesson 1: Preparing for Installation

Lesson 1: Preparing for Installation 2-2 Chapter 2 Installing Windows XP Professional Lesson 1: Preparing for Installation When you install Windows XP Professional, the Windows XP Professional Setup program allows you to specify how to install

More information

hp StorageWorks Library and Tape Tools

hp StorageWorks Library and Tape Tools hp StorageWorks Library and Tape Tools v3.5 Getting Started Guide Copyright 2002-2004 Hewlett-Packard Development Company, L.P. Hewlett-Packard Company makes no warranty of any kind with regard to this

More information

Configuration Information for Firmware Version 4.29

Configuration Information for Firmware Version 4.29 NEO SERIES 2000-4000 Configuration Information for Firmware Version 4.29 This document contains information on the configuration options for the NEO SERIES 2000-4000 tape libraries. 1 Description of Configuration

More information

How to integrate HP StorageWorks tape libraries into a SAN based backup environment.

How to integrate HP StorageWorks tape libraries into a SAN based backup environment. HP World Chicago August 16 20 2004 How to integrate HP StorageWorks tape libraries into a SAN based backup environment. Presentation 1 (20 mins) : HP Extended Tape Library Architecture (ETLA) Overall Lab

More information

Print Server Administration User s Guide

Print Server Administration User s Guide Print Server Administration User s Guide ii About This Guide Table of Contents ABOUT THIS GUIDE... 1 What s Not Covered in This User s Guide... 1 Contents of the User s Guide... 2 INTRODUCTION... 3 Background

More information

CA Agile Central Administrator Guide. CA Agile Central On-Premises

CA Agile Central Administrator Guide. CA Agile Central On-Premises CA Agile Central Administrator Guide CA Agile Central On-Premises 2018.1 Table of Contents Overview... 3 Server Requirements...3 Browser Requirements...3 Access Help and WSAPI...4 Time Zone...5 Architectural

More information

DAT Optic Inc Universal FireWire Enclosure User s Manual Rev 1.0

DAT Optic Inc Universal FireWire Enclosure User s Manual Rev 1.0 DAT Optic Inc Universal FireWire Enclosure User s Manual Rev 1.0 Universal FireWire Enclosure- User s Manual Page 01 Contents INTRODUCTION... Major Features... Package Contents... Universal FireWire Enclosure

More information

GSS Administration and Troubleshooting

GSS Administration and Troubleshooting CHAPTER 9 GSS Administration and Troubleshooting This chapter covers the procedures necessary to properly manage and maintain your GSSM and GSS devices, including login security, software upgrades, GSSM

More information

NETePay XML. Installation & Configuration Guide. For Concord EFSnet. Version 3.11

NETePay XML. Installation & Configuration Guide. For Concord EFSnet. Version 3.11 NETePay XML Installation & Configuration Guide Version 3.11 For Concord EFSnet NETePay XML Installation & Configuration Guide Copyright 2007 Datacap Systems Inc. All rights reserved. This manual and the

More information

WinClient Remote Manager USER S MANUAL. Revision: WRM /10/22

WinClient Remote Manager USER S MANUAL. Revision: WRM /10/22 WinClient Remote Manager USER S MANUAL Revision: WRM 2.1 2002/10/22 Copyright This manual and any accompanying software and firmware are copyrighted. No parts of this publication may be reproduced, stored

More information

Sun VirtualBox Installation Tutorial

Sun VirtualBox Installation Tutorial Sun VirtualBox Installation Tutorial Installing Linux Mint 5 LTS Guest OS By Dennis Berry Welcome to the world of virtualization and Linux. This tutorial is intended to help users who are new to the world

More information

HP Server tc2110 Network Operating System Installation Guide

HP Server tc2110 Network Operating System Installation Guide HP Server tc2110 Network Operating System Installation Guide For: Microsoft Windows NT 4.0 Server Microsoft Windows 2000 Server and Microsoft Small Business Server 2000 Novell NetWare 5.1 and Novell Small

More information

NETePay XML. Installation & Configuration Guide. For Moneris (Public) Version 3.00

NETePay XML. Installation & Configuration Guide. For Moneris (Public) Version 3.00 NETePay XML Installation & Configuration Guide Version 3.00 For Moneris (Public) NETePay XML Installation & Configuration Guide Copyright 2005 Datacap Systems Inc. All rights reserved. This manual and

More information

Page 1 of 5. Rental Network Software Corp., Rental Management Software v9.0 (R90) Release Notes. Topics Covered:

Page 1 of 5. Rental Network Software Corp., Rental Management Software v9.0 (R90) Release Notes. Topics Covered: Rental Network Software Corp., Rental Management Software v9.0 (R90) Release Notes Topics Covered: 1. Supported Configurations 2. Terminal Server 3. MDAC 2.7 Compatibility 4. Installing the application

More information

VMware Workstation 4 What s New Requirements Installation Guest OS Installation Documentation Troubleshooting Prev Contents Last Next Installing VMware Tools The following sections describe how to install

More information

Physical-to-Virtual Migration with Portlock Storage Manager

Physical-to-Virtual Migration with Portlock Storage Manager PO RTL OC K Physical-to-Virtual Migration with Portlock Storage Manager Table of Contents Introduction... 3 About this Document... 3 About the Reader... 3 About Portlock Storage Manager and the Portlock

More information

Configuring the MSA1000 for Linux or NetWare Environments

Configuring the MSA1000 for Linux or NetWare Environments White Paper September 2002 Prepared by: Network Storage Solutions Hewlett Packard Company Contents Benefits of the new firmware for the MSA1000...1 Prerequisites...3 Firmware Upgrades:...3 Environmental

More information

Upgrading the MSA1000 for Enhanced Features

Upgrading the MSA1000 for Enhanced Features White Paper December 2002 Prepared by: Network Storage Solutions Hewlett Packard Company Contents Benefits of the MSA1000 Enhancements...1 Prerequisites...3 Environmental Monitoring Unit (EMU) issue:...3

More information

8 MANAGING SHARED FOLDERS & DATA

8 MANAGING SHARED FOLDERS & DATA MANAGING SHARED FOLDERS & DATA STORAGE.1 Introduction to Windows XP File Structure.1.1 File.1.2 Folder.1.3 Drives.2 Windows XP files and folders Sharing.2.1 Simple File Sharing.2.2 Levels of access to

More information

Installing the IBM ServeRAID Cluster Solution

Installing the IBM ServeRAID Cluster Solution Installing the IBM ServeRAID Cluster Solution For IBM Netfinity ServeRAID-4x Ultra160 SCSI Controllers Copyright IBM Corp. 2000 1 2 IBM Netfinity Installing the IBM ServeRAID Cluster Solution Chapter 1.

More information

Client Data System. Installation Guide Version 4.3 (Network Version - Servers)

Client Data System. Installation Guide Version 4.3 (Network Version - Servers) Client Data System Installation Guide Version 4.3 (Network Version - Servers) Revised: 1/4/2005 Copyright 1998-2004, E-Z Data, Inc. All Rights Reserved. No part of this documentation may be copied, reproduced,

More information

Cisco Unified CME Telephony Service Provider 2.1 Setup Guide

Cisco Unified CME Telephony Service Provider 2.1 Setup Guide Cisco Unified CME Telephony Service Provider 2.1 Setup Guide Revised: January 12, 2007 Introduction Cisco Unified Communications Manager Express (Cisco Unified CME, formerly known as Cisco Unified CallManager

More information

GIFTePay XML SVS/GCS. Installation & Configuration Guide. Version Part Number: (ML) (SL) GIFTePay XML for SVS/GCS 4.

GIFTePay XML SVS/GCS. Installation & Configuration Guide. Version Part Number: (ML) (SL) GIFTePay XML for SVS/GCS 4. GIFTePay XML Installation & Configuration Guide SVS/GCS Version 4.01 Part Number: 8662.97 (ML) 8662.98 (SL) GIFTePay XML for SVS/GCS 4.01 1 GIFTePay XML Installation & Configuration Guide Copyright 2008

More information

Perle Dial-Out User s Guide

Perle Dial-Out User s Guide Perle Dial-Out User s Guide 95-2345-05 Copyrights Copyright 1996-2000, Perle Systems Limited and its suppliers. IBM is the registered trademark of International Business Machines Corporation. Microsoft,

More information

Client Data System. Upgrade Guide. CDS v3.2 to v4.1.1 (Network Version) Client Data System Upgrade Guide 3.2 to (Network) Revised:

Client Data System. Upgrade Guide. CDS v3.2 to v4.1.1 (Network Version) Client Data System Upgrade Guide 3.2 to (Network) Revised: Client Data System Upgrade Guide CDS v3.2 to v4.1.1 (Network Version) Copyright 2003, E-Z Data, Inc. E-Z Data, Inc. 918 East Green Street Pasadena, CA 91106 Telephone: (626) 585-3505 Fax: (626) 440-9097

More information

Serial ATA PCI RAID Quick Installation Guide

Serial ATA PCI RAID Quick Installation Guide Serial ATA PCI RAID Quick Installation Guide Introducing the Serial ATA PCI RAID The Serial ATA PCI RAID is an ultra high-speed two channel Serial ATA controller board for use in Pentium-class computers.

More information

Step-by-Step Guide to Installing Cluster Service

Step-by-Step Guide to Installing Cluster Service Page 1 of 23 TechNet Home > Products & Technologies > Windows 2000 Server > Deploy > Configure Specific Features Step-by-Step Guide to Installing Cluster Service Topics on this Page Introduction Checklists

More information

Transport Gateway Installation / Registration / Configuration

Transport Gateway Installation / Registration / Configuration CHAPTER 2 Transport Gateway Installation / Registration / Configuration This chapter covers the following areas: Transport Gateway requirements. Security Considerations When Using a Transport Gateway.

More information

CA Agile Central Installation Guide On-Premises release

CA Agile Central Installation Guide On-Premises release CA Agile Central Installation Guide On-Premises release 2016.2 Agile Central to Go 2017.1 rallysupport@rallydev.com www.rallydev.com 2017 CA Technologies (c) 2017 CA Technologies Version 2016.2 (c) Table

More information

Client Data System. Upgrade Guide. CDS v4.0 to v Client Data System Upgrade Guide v4.0 to v4.1.1 Revised:

Client Data System. Upgrade Guide. CDS v4.0 to v Client Data System Upgrade Guide v4.0 to v4.1.1 Revised: Client Data System Upgrade Guide CDS v4.0 to v4.1.1 Copyright 2002, E-Z Data, Inc. E-Z Data, Inc. 918 East Green Street Pasadena, CA 91106 Web: http://www.ez-data.com Telephone: (626) 585-3505 Fax: (626)

More information

Mailbox Manager Getting Started Guide. Licensing Installation Options System Requirements Installation Instructions

Mailbox Manager Getting Started Guide. Licensing Installation Options System Requirements Installation Instructions Mailbox Manager Getting Started Guide Licensing Installation Options System Requirements Installation Instructions Mailbox Manager Release 5.4 December 2006 Table of Contents Introduction... 1 Licenses...

More information

PROMISE ARRAY MANAGEMENT ( PAM) FOR FastTrak S150 TX2plus, S150 TX4 and TX4000. User Manual. Version 1.3

PROMISE ARRAY MANAGEMENT ( PAM) FOR FastTrak S150 TX2plus, S150 TX4 and TX4000. User Manual. Version 1.3 PROMISE ARRAY MANAGEMENT ( PAM) FOR FastTrak S150 TX2plus, S150 TX4 and TX4000 User Manual Version 1.3 Promise Array Management Copyright 2003 Promise Technology, Inc. All Rights Reserved. Copyright by

More information

HPE Library and Tape Tools 4.26 User Guide

HPE Library and Tape Tools 4.26 User Guide HPE Library and Tape Tools 4.26 User Guide Part Number: 876941-003 Published: January 2018 Edition: 1 Copyright 1999, 2018 Hewlett Packard Enterprise Development LP Notices The information contained herein

More information

Contents. Getting Started...1. Managing Your Drives...9. Backing Up & Restoring Folders Synchronizing Folders...52

Contents. Getting Started...1. Managing Your Drives...9. Backing Up & Restoring Folders Synchronizing Folders...52 Contents Getting Started.....................................................1 Installing the Software...........................................1 Using the Maxtor System Tray Icon................................6

More information

Chapter 8 Operating Systems and Utility Programs أ.أمل زهران

Chapter 8 Operating Systems and Utility Programs أ.أمل زهران Chapter 8 Operating Systems and Utility Programs Chapter 8 Objectives Identify the types of system software Summarize the startup process on a personal computer Summarize the features of several stand-alone

More information

V Workstation Imaging

V Workstation Imaging V Workstation Imaging The following sections provide information on Novell ZENworks Desktop Management Workstation Imaging procedures and features. Chapter 50, Common Imaging Deployment Strategies, on

More information

GigaRAID (IT8212) ATA RAID Controller USER S MANUAL

GigaRAID (IT8212) ATA RAID Controller USER S MANUAL GigaRAID (IT8212) ATA RAID Controller USER S MANUAL 12ME-IT8212-005 Copyright Copyright by GIGA-BYTE TECHNOLOGY CO., LTD. ( GBT ) No part of this manual may be reproduced or transmitted in any from without

More information

SCSI device drivers are provided for the following operating systems:

SCSI device drivers are provided for the following operating systems: This section describes how to install and configure the Dell small computer system interface (SCSI) device drivers included with your Dell PowerEdge computer system. These device drivers are designed to

More information

Business Communications Manager 3.0 Attendant Console Set Up and Operation Guide

Business Communications Manager 3.0 Attendant Console Set Up and Operation Guide Part No. P0936570 04 Business Communications Manager 3.0 Attendant Console Set Up and Operation Guide 2 Copyright 2002 Nortel Networks All rights reserved. The information in this document is subject to

More information

Drobo 5N2 User Guide

Drobo 5N2 User Guide Drobo 5N2 User Guide Contents 1 Drobo 5N2 User Guide... 6 1.1 Before You Begin... 7 1.1.1 Product Features at a Glance... 8 1.1.2 Checking Box Contents...10 1.1.3 Checking System Requirements...11 1.1.3.1

More information

Windows Me Navigating

Windows Me Navigating LAB PROCEDURE 11 Windows Me Navigating OBJECTIVES 1. Explore the Start menu. 2. Start an application. 3. Multi-task between applications. 4. Moving folders and files around. 5. Use Control Panel settings.

More information

PC and Windows Installation 32 and 64 bit Operating Systems

PC and Windows Installation 32 and 64 bit Operating Systems SUDAAN Installation Guide PC and Windows Installation 32 and 64 bit Operating Systems Release 11.0.1 Copyright 2013 by RTI International P.O. Box 12194 Research Triangle Park, NC 27709 All rights reserved.

More information

3 INSTALLING WINDOWS XP PROFESSIONAL

3 INSTALLING WINDOWS XP PROFESSIONAL INSTALLING WINDOWS XP PROFESSIONAL.1 Preparing for installation Objectives.1.1 Windows XP Professional Hardware Requirements.1.2 Hardware Compatibility List (HCL) check.1. Hard Disk Partition.1.4 Required

More information

Managing the VPN Client

Managing the VPN Client Managing the VPN Client This chapter explains the tasks you can perform to manage connection entries, view and manage event reporting, and upgrade or uninstall the VPN Client software. The management features

More information

SANsurfer iscsi HBA Application User s Guide

SANsurfer iscsi HBA Application User s Guide Q Simplify SANsurfer iscsi HBA Application User s Guide Management Application for SANsurfer iscsi Host Bus Adapters IS0054602-00 A Page i SANsurfer iscsi HBA Application User s Guide Management Application

More information

Lab 03. Windows Operating Systems (Cont.)

Lab 03. Windows Operating Systems (Cont.) Lab 03 s (Cont.) Objectives Develop a good understanding of 1. The role of an operating system in a computer system 2. Services provided by an operating system and have some hands on experience in 1. Understanding

More information

Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5

Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5 Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5 Getting Started with ESX Server 3i Installable Revision: 20090313 Item:

More information

GIFTePay XML. Valuelink. Installation & Configuration Guide. Version Part Number: (ML) (SL)

GIFTePay XML. Valuelink. Installation & Configuration Guide. Version Part Number: (ML) (SL) GIFTePay XML Installation & Configuration Guide Valuelink Version 4.10 Part Number: 8662.92 (ML) 8662.93 (SL) GIFTePay XML Installation & Configuration Guide Copyright 2008 Datacap Systems Inc. All rights

More information

GIFTePay XML. Chockstone. Installation & Configuration Guide. Version Part Number: (ML) (SL)

GIFTePay XML. Chockstone. Installation & Configuration Guide. Version Part Number: (ML) (SL) GIFTePay XML Installation & Configuration Guide Chockstone Version 4.00 Part Number: 8662.65 (ML) 8662.66 (SL) GIFTePay XML Installation & Configuration Guide Copyright 2009 Datacap Systems Inc. All rights

More information

Chapter 8 Operating Systems and Utility Programs

Chapter 8 Operating Systems and Utility Programs Chapter 8 Operating Systems and Utility Programs Chapter 8 Objectives Identify the types of system software Summarize the startup process on a personal computer Summarize the features of several stand-alone

More information

Release Note - Updating Embedded NT Systems

Release Note - Updating Embedded NT Systems Release Note - Updating Embedded NT Systems There are several issues to consider when upgrading a PX PowerStation that uses Embedded NT on a Compact Flash. This release note provides procedures for the

More information

Data Protector Express Hewlett-Packard Company

Data Protector Express Hewlett-Packard Company Installation Guide Data Protector Express Hewlett-Packard Company ii Data Protector Express Installation Guide Copyright Copyright 2005/2006 by Hewlett-Packard Limited. March 2006 Part Number BB116-90024

More information

CCNA 1 Chapter 2 v5.0 Exam Answers %

CCNA 1 Chapter 2 v5.0 Exam Answers % CCNA 1 Chapter 2 v5.0 Exam Answers 2015 100% 1. Which two features are characteristics of flash memory? (Choose two.) Flash provides nonvolatile storage. Flash receives a copy of the IOS from RAM when

More information

JNIOR. A Network I/O Resource Utilizing the JAVA Platform. JNIOR Support Tool Manual. Release 6.0

JNIOR. A Network I/O Resource Utilizing the JAVA Platform. JNIOR Support Tool Manual. Release 6.0 JNIOR A Network I/O Resource Utilizing the JAVA Platform Release 6.0 Supports JNIOR Series 3 and 4 JNIOR OS 3.4 or greater required INTEG Process Group, Inc. 2919 East Hardies Rd, First Floor Gibsonia,

More information

Configuration Guide. Upgrading AOS Firmware L1-29.1D July 2011

Configuration Guide. Upgrading AOS Firmware L1-29.1D July 2011 61200990L1-29.1D July 2011 Configuration Guide This configuration guide explains how to update your ADTRAN Operating System (AOS) firmware using the AOS Web-based graphical user interface (GUI) with Trivial

More information

Windows NT Server Printer Driver Upgrade Instructions

Windows NT Server Printer Driver Upgrade Instructions Windows NT Server Printer Driver Upgrade Instructions The steps detailed below describe the most reliable method to upgrade printer driver versions after v1.6.0227a on a Windows NT 4.0 Server that is shared

More information

Axel Remote Management Version 2

Axel Remote Management Version 2 Axel Remote Management Version 2 Administration Software for Axel Terminals and Office Servers May 2009 - Ref.: AxRM2E-16 The reproduction of this material, in part or whole, is strictly prohibited. For

More information

How to install the software of ZNS8022

How to install the software of ZNS8022 How to install the software of ZNS8022 1. Please connect ZNS8022 to your PC after finished assembly. 2. Insert Installation CD to your CD-ROM drive and initiate the auto-run program. The wizard will run

More information

Reinstalling the Operating System on the Dell PowerVault 745N

Reinstalling the Operating System on the Dell PowerVault 745N Reinstalling the Operating System on the Dell PowerVault 745N This document details the following steps to reinstall the operating system on a PowerVault 745N system: 1. Install the Reinstallation Console

More information

VIRTUALIZATION MANAGER ENTERPRISE EDITION GETTING STARTED GUIDE. Product: Virtual Iron Virtualization Manager Version: 4.2

VIRTUALIZATION MANAGER ENTERPRISE EDITION GETTING STARTED GUIDE. Product: Virtual Iron Virtualization Manager Version: 4.2 VIRTUALIZATION MANAGER ENTERPRISE EDITION GETTING STARTED GUIDE This manual provides a quick introduction to Virtual Iron software, and explains how to use Virtual Iron Virtualization Manager to configure

More information

To upgrade to the i-vu v6.0 application

To upgrade to the i-vu v6.0 application i-vu Application Upgrade Guide to v6.0 CARRIER CORPORATION 2014 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-493-01 3/21/2014 Table of Contents To upgrade

More information

User Guide 701P Wide Format Solution Wide Format Scan Service

User Guide 701P Wide Format Solution Wide Format Scan Service User Guide 701P44865 6204 Wide Format Solution Wide Format Scan Service Xerox Corporation Global Knowledge & Language Services 800 Phillips Road Bldg. 845-17S Webster, NY 14580 Copyright 2006 Xerox Corporation.

More information

RocIT Defender User s Guide ViSoS TM Virtual System on a Stick

RocIT Defender User s Guide ViSoS TM Virtual System on a Stick RocIT Defender User s Guide ViSoS TM Virtual System on a Stick Table of Contents 1. Introduction 3 1.1. Minimum System Requirements 3 1.2. Drive Specifications 4 2. Startup Procedure 4 2.1. Configure computer

More information

Installing the Operating System or Hypervisor

Installing the Operating System or Hypervisor If you purchased E-Series Server or NCE Option 1 (E-Series Server or NCE without a preinstalled operating system or hypervisor), you must install an operating system or hypervisor. This chapter includes

More information

Serial ATA PCI RAID Quick Installation Guide

Serial ATA PCI RAID Quick Installation Guide Serial ATA PCI RAID Quick Installation Guide Introducing the Serial ATA PCI RAID The Serial ATA PCI RAID is an ultra high-speed two channel Serial ATA controller board for use in Pentium-class computers.

More information

DBT-120 Bluetooth USB Adapter

DBT-120 Bluetooth USB Adapter DBT-120 Bluetooth USB Adapter Rev.2.1 (09/25/2002) 2 Contents Introduction... 5 Package Contents... 6 Installing Bluetooth Software... 6 Hardware Installation... 8 Introduction to Bluetooth Software...

More information

Performing Maintenance Operations

Performing Maintenance Operations This chapter describes how to back up and restore Cisco Mobility Services Engine (MSE) data and how to update the MSE software. It also describes other maintenance operations. Guidelines and Limitations,

More information

SATARaid Serial ATA RAID Management Software

SATARaid Serial ATA RAID Management Software SATARaid Serial ATA RAID Management Software 05/12/04 Silicon Image, Inc. 1060 East Arques Ave. Sunnyvale CA 94085 (408) 616-4000 www.siliconimage.com Copyright 2003, Silicon Image, Inc. All rights reserved.

More information

SQLBase. Starter Guide

SQLBase. Starter Guide SQLBase Starter Guide 20-2905-1004 Trademarks Centura, Centura net.db, Centura Ranger, the Centura logo, Centura Web Developer, Gupta, the Gupta logo, Gupta Powered, the Gupta Powered logo, Fast Facts,

More information

IBM NetBAY Virtual Console Software. Installer and User Guide

IBM NetBAY Virtual Console Software. Installer and User Guide IBM NetBAY Virtual Console Software Installer and User Guide INSTRUCTIONS This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the

More information

VI-CENTER EXTENDED ENTERPRISE EDITION GETTING STARTED GUIDE. Version: 4.5

VI-CENTER EXTENDED ENTERPRISE EDITION GETTING STARTED GUIDE. Version: 4.5 VI-CENTER EXTENDED ENTERPRISE EDITION GETTING STARTED GUIDE This manual provides a quick introduction to Virtual Iron software, and explains how to use Virtual Iron VI-Center to configure and manage virtual

More information

HOW TO: Establishing a VPN Connection For use with File Sharing on Windows 98, 2000, and Windows XP

HOW TO: Establishing a VPN Connection For use with File Sharing on Windows 98, 2000, and Windows XP HOW TO: Establishing a VPN Connection For use with File Sharing on Windows 98, 2000, and Windows XP 1. Go to the Start Menu, choose Programs, Accessories, Communications, and open the Network Connections

More information

BACKUP APP V7 QUICK START GUIDE FOR SYNOLOGY NAS

BACKUP APP V7 QUICK START GUIDE FOR SYNOLOGY NAS BACKUP APP V7 QUICK START GUIDE FOR SYNOLOGY NAS Revision History Date Descriptions Type of modification 29 Jun 2016 First Draft New 25 Nov 2016 Modified Ch 3 Download Backup App, Ch 3 Install Backup App

More information

Installing AppleWorks 6 FOR WINDOWS

Installing AppleWorks 6 FOR WINDOWS apple Installing AppleWorks 6 FOR WINDOWS 1 Installing AppleWorks 6 This booklet provides instructions for m installing and uninstalling AppleWorks m setting up an AppleWorks Installer on a server, so

More information

Version 11. NOVASTOR CORPORATION NovaBACKUP

Version 11. NOVASTOR CORPORATION NovaBACKUP NOVASTOR CORPORATION NovaBACKUP Version 11 2009 NovaStor, all rights reserved. All trademarks are the property of their respective owners. Features and specifications are subject to change without notice.

More information

LevelOne Broadband Routers

LevelOne Broadband Routers LevelOne Broadband Routers FBR-1100TX FBR-1400TX FBR-1401TX FBR-1700TX User's Guide TABLE OF CONTENTS CHAPTER 1 INTRODUCTION... 1 Features of your LevelOne Broadband Router... 1 Package Contents... 4

More information

Chapter. Accessing Files and Folders MICROSOFT EXAM OBJECTIVES COVERED IN THIS CHAPTER

Chapter. Accessing Files and Folders MICROSOFT EXAM OBJECTIVES COVERED IN THIS CHAPTER Chapter 10 Accessing Files and Folders MICROSOFT EXAM OBJECTIVES COVERED IN THIS CHAPTER Monitor, manage, and troubleshoot access to files and folders. Configure, manage, and troubleshoot file compression

More information

GadgetPC Single Board Computer. System Restore Guide. Document Revision: 1.04 Date: 31 January, 2010

GadgetPC Single Board Computer. System Restore Guide. Document Revision: 1.04 Date: 31 January, 2010 GadgetPC Single Board Computer System Restore Guide Document Revision: 1.04 Date: 31 January, 2010 BiPOM Electronics, Inc. 16301 Blue Ridge Road, Missouri City, Texas 77489 Telephone: 1-713-283-9970 Fax:

More information

OPERATING SYSTEMS & UTILITY PROGRAMS

OPERATING SYSTEMS & UTILITY PROGRAMS OPERATING SYSTEMS & UTILITY PROGRAMS System Software System software consists of the programs that control the operations of the computer and its devices. Functions that system software performs include:

More information

bs^ir^qfkd=obcib`qflk= prfqb=clo=u

bs^ir^qfkd=obcib`qflk= prfqb=clo=u bs^ir^qfkd=obcib`qflk= prfqb=clo=u cçê=u=táåççïë=póëíéãë cçê=lééåsjp=eçëíë cçê=f_j=eçëíë 14.1 bî~äì~íáåö=oéñäéåíáçå=u This guide provides a quick overview of features in Reflection X. This evaluation guide

More information

Contents. 1 Drobo 5C Online User Guide Before You Begin Product Features at a Glance Checking Box Contents...

Contents. 1 Drobo 5C Online User Guide Before You Begin Product Features at a Glance Checking Box Contents... Drobo 5C User Guide Contents 1 Drobo 5C Online User Guide... 6 1.1 Before You Begin... 7 1.1.1 Product Features at a Glance... 8 1.1.2 Checking Box Contents... 10 1.1.3 Checking System Requirements...

More information

DSView. Installer/User Guide

DSView. Installer/User Guide DSView Installer/User Guide DSView Installer/User Guide Avocent, the Avocent logo, The Power of Being There, OutLook, DSView, AutoView, DSR, Dambrackas Video Compression, Click and Connect and OSCAR are

More information

Software Installation Guide for the QLA22xx Board Family. Fibre Channel Host Adapter Boards for the PCI Bus

Software Installation Guide for the QLA22xx Board Family. Fibre Channel Host Adapter Boards for the PCI Bus Software Installation Guide for the QLA22xx Board Family Fibre Channel Host Adapter Boards for the PCI Bus FC0153302-00 F July 20, 2001 QLogic Corporation Information furnished in this manual is believed

More information

Channel 4. User Manual. Version 2.0

Channel 4. User Manual. Version 2.0 Channel 4 User Manual Version 2.0 Table Of Contents Introduction... 1 System Requirements... 2 Installation... 3 Creating a Program... 7 Uploading a Program... 8 Support... 8 Introduction Evsl s Channel

More information

USB 2.0 Print Server. User s Manual. Rev. 01 (Jan, 2004) Made In Taiwan

USB 2.0 Print Server. User s Manual. Rev. 01 (Jan, 2004) Made In Taiwan USB 2.0 Print Server User s Manual Rev. 01 (Jan, 2004) Made In Taiwan TABLE OF CONTENTS ABOUT THIS GUIDE... 4 INTRODUCTION... 5 PACKAGE CONTENTS... 6 SYSTEM REQUIREMENTS... 6 GENERAL FEATURES... 7 PRODUCT

More information

Extended Search Administration

Extended Search Administration IBM Lotus Extended Search Extended Search Administration Version 4 Release 0.1 SC27-1404-02 IBM Lotus Extended Search Extended Search Administration Version 4 Release 0.1 SC27-1404-02 Note! Before using

More information

Establishing FTP Services on a NetWare 4 Server

Establishing FTP Services on a NetWare 4 Server Establishing FTP Services on a NetWare 4 Server BY JOHN E. JOHNSTON The NetWare FTP Service allows users from any platform that provides the FTP utility to access the NetWare file system. NetWare FTP Service

More information

Transport Gateway Installation / Registration / Configuration

Transport Gateway Installation / Registration / Configuration CHAPTER 4 Transport Gateway Installation / Registration / Configuration This chapter covers the following areas: Transport Gateway requirements. Security Considerations When Using a Transport Gateway.

More information

BiPAC BiPAC User Manual

BiPAC BiPAC User Manual BiPAC 2071 HomePlug AV 200 Ethernet Adapter BiPAC 2072 HomePlug AV 200 Ethernet Bridge with AC-Pass Through User Manual Table of Contents Chapter 1...1 Introduction...1 Specifications...2 Features...3

More information

1. ECI Hosted Clients Installing Release 6.3 for the First Time (ECI Hosted) Upgrading to Release 6.3SP2 (ECI Hosted)

1. ECI Hosted Clients Installing Release 6.3 for the First Time (ECI Hosted) Upgrading to Release 6.3SP2 (ECI Hosted) 1. ECI Hosted Clients........................................................................................... 2 1.1 Installing Release 6.3 for the First Time (ECI Hosted)...........................................................

More information