VIOS Shared Storage Pool 6 Reminder of the Basics & Advanced Topics & Demo

Size: px
Start display at page:

Download "VIOS Shared Storage Pool 6 Reminder of the Basics & Advanced Topics & Demo"

Transcription

1 AIX Virtual User Group VIOS Shared Storage Pool 6 Reminder of the Basics & Advanced Topics & Demo Nigel Griffiths Power Systems Advanced Technology Support IBM Europe 2016 IBM Corporation

2 Agenda 2 Info: Benefits, Videos & Blogs, class 101 Reminder Four Frequently Ask Questions SSP phase 5 Tiers reminder SSP phase 6 8 New features Five new-ish free SSP commands from Nigel Under the cover secrets

3 Shared Storage Pool terminology 3 Cluster = set of co-operating VIOSs Pool = set of LUNs connected to the cluster So every VIOS sees every LUN LU = Logical Unit = SSP virtual disk out of the pool Space allocated in chunks of 1MB VIOS vscsi connection to virtual machines: AIX, Linux, IBMi Special LUN called a Repository disk for cluster config Typically, 1 or 2 GB is size. Can be rebuilt in seconds. SSP commands are simple to use cluster, lscluster, lu, pv, failgrp, lssp & tier (new)

4 Shared Storage Pools = SSP 4 We are at Phase 6 which means: Six years of development & releases Lots of concepts & features Covering the basics takes much more than 1 hour Pre-Requistes for this SSP session 1. Technical Uni Session by Linda Flanders 2. Or Power Systems SSP Webinars on Phase 4 mins Phase mins 3. Or 1 years+ Hands-On with SSP

5 Nigel s YouTube Videos 5 ~16,100 YouTube views in total 1. SSP Intro 7 mins SSP2 Getting Started 10 mins SSP2 Thin Provisioning Alerts 17 mins SSP3 New Features 24 mins Looking Around a SSP3 15 mins Live Partition Mobility (LPM) with SSP3 7 mins Recover a Crashed Machine's LPAR to Another Machine 25 mins Migrating to SSP & then LPM 18 mins SSP 4 Concepts 28 mins SSP 4 Hands On 19 mins PowerVC with SSP 20 mins SSP in 3 Commands in 3 Minutes 8 mins SSP Repository is bullet proof 13 mins SSP Remote Pool Copy Activation for Disaster Recovery 23 mins PowerVM VUG 33: VIOS Shared Storage Pool mins Power Systems VUG 50: VIOS Shared Storage Pool 5 90 mins VIOS Shared Storage Pool phase 6 19 mins 269 YouTube search: Shared Storage Pools Nigel Griffiths

6 Nigel s AIXpert Blog topics on SSP 6 1. VIOS Shared Storage Pool phase 6 - New Readme Content 2. VIOS Shared Storage Pool phase 6 - New Features 3. Shared Storage Pools - Migrating to New Disk Subsystem 4. Shared Storage Pools question on two pools? 5. Shared Storage Pool 5 - VIOS upgrade status script 6. Shared Storage Pools 5 - advanced lu -list the search continues 7. Shared Storage Pools - Hands-On Fun with Virtual Disks (LU) by Example * Download my SSP tools from this Blog Views 8. Shared Storage Pool 4 - Best Practice & FAQ * Updated to cover SSP6 13,660+ Views 9. Shared Storage Pools 4 - Growing the Pool using LUN Expansion 10.Shared Storage Pools 4 - Cheat Sheet * Command summary by example 11.How many Shared Storage Pools in the world? 12.VIOS Shared Storage Pool Single Repository Disk = Not a Problem * 13.VIOS Shared Storage Pool phase 4 - How fast is the disk I/O?...

7 Marketing: VIOS Shared Storage Pools 1. Enormous reduction in storage man-power 2. Sub-second disk space allocate & connect a VM lu command: create, map, unmap, remove lu level snapshot: create/delete/rollback 3. Easy to live assimilate a local disk VM for I/O boost 4. Autonomic disk mirrors & resilver with zero VM effort 7 Avoid troublesome Linux mirrors and AIX stale mirror hunting 5. Live Partition Mobility ready by default 6. Simple Pool management: pv & failgrp, lssp, lscluster/cluster, alert HMC logs 7. DR capability to rebuild the whole SSP & a VM quickly 8. HMC GUI for fast SSP disk setup across dual VIOS No more: VIOS slot numbers, Cnn or vhosts 9. Tiers: separate groups of LUNs with different disk properties For mixed SSD/HDD and live migrate VM to different disks 10.As fast as NPIV (takes a little more VIOS CPU but look at the functions you get) 11.Independence from underlying SAN technology & team!

8 SSP Architecture 8

9 SSP5 Webinar 9 Architecture Initial setup = EASY LUNs+Zone & online in VIOSs cluster create cluster -addnode (of each VIOS) failgrp create Have a mirrored SSP lu -create -lu xyz -size 64G -vadapter vhost42 1 st VIOS 1 sec later: disk online in VM lu -map -lu xyz -vadapter vhost66 1 sec later: dual VIOS 2 nd VIOS pv -add more-luns

10 SSP5 Webinar 10 Architecture Initial setup = EASY 3 Advanced Functions LPM by default Adopt old VM into SSP Simple VM recovery

11 FAQ 1: Supported? 11 Are my disks supported by SSP? If supported by VIOS then they are good for SSP webapp/set2/sas/f/vios/documentation/datasheet.html How do I get Shared Storage Pools 6? SSP6 delivered as VIOS fix packs So just upgrade your VIOS Does SSP support NPIV? No it does not, never will and it is impossible! What a silly question

12 FAQ 2: Rate in terms of high speed Disks 12 Local VIOS disk via vscsi LU over SSP SAN LUN over NPIV FC LUN via vscsi

13 Rate in terms of Disk speed 13 SSP NPIV LUN via vscsi Local disk via vscsi Shocking, right! Benchmarked at IBM Montpellier to prove it I/O per second Latency Notes: 1 SSP does take a little more CPU than NPIV but SSP has drastically less SysAdmin time 2 NPIV itself has no automatic mirrors & resilver, sub-second create and assign 3 NPIV disk subsystem might have snapshots, simple cloning, thin provisioning 4 VM with single LU/LUN SSP faster

14 14 SSP5 Tiers - a quick dip

15 Phase 5 November 2015 SSP Tiers (multiple pools, only better) 9 tiers (think disk grouping - not hierarchy of levels) Systems tier (with meta data) or User tier (data only) failgrp (mirroring) at tier level [was whole pool level] tier -create -tier blue: <list of LUNs> lu -create -lu fred -size 32G -tier blue 15 SSP LU move a LU between tiers Command: lu -move -lu vm42 -dsttier blue SSP LU Resize (grow only, saves admin time) Command: lu -resize-lu vm42 size 128G SSP + Tier support in HMC Enhanced+ view VIOS alerts escalated to HMC for Tiers

16 What is good Tier use? 16 It is about the underlying disks Fast, medium, slow highlight the LUNs have different performance IBM, HDS, EMC remind yourself of the underlying disk unit vendor and implications of that Prod, in-house, test make sure you know different policies are in place for the important data V7000a, V7000b you know explicitly which disk unit the data is in to reduce risks Room101 & Room102, datacentre1 & datecentre2 clarify where (geographically) the LUNs are placed Remote-mirror, Local-mirror, Un-mirrored Key: Green Red Blue separate disk remotely mirrored (failgrp in SSP terms), locally mirrored or not mirrored Storage Speed Location Protection(RAS) Bad use of Tiers: rootvg & data VG RDBMS data & logs

17 VIOS tier related command 17 How to mirror a tier? failgrp -create -tier tiername... failgrp -create -tier red -fg mirrorb: hdisk30 hdisk31 How to move a LU between tiers? lu -move -lu luname -dsttier tiername lu -move -lu vm42boot -dsttier red How to grow a tier in size? pv -add -tier tiername pv -add -tier red -fg mirrora: hdisk22 fg mirrorb: hdisk32

18 18 SSP6 What s New?

19 Phase 6 November Available with VIOS th Nov 1. Increased SSP VIOS nodes from 16 to Fully support the DeveloperWorks SSP Disaster Recovery software 3. RAS (Reliable, Available & Serviceable) 3a Cluster Wide Snap Automation 3b Asymmetric Network Handling 3c Lease by Clock Tick 4. lu -list -attr provisioned=<true/false> 5. HMC further GUI support for SSP Arrives with HMC HMC Performance & Capacity Metrics (SSP Performance stats)

20 SSP 6 VIOS nodes 1. Increased SSP VIOS nodes from 16 to In Practice: With the normal Dual VIOSs = 12 Servers Note: Live Partition Mobility within the 12 Servers Need more? Use more than one SSP This limits the failure domain Largely a Test & Support Statement Large effort for SSP development test They assume worst case extremely high disk I/O rates

21 SSP 6 24 VIOS nodes Nigel Notes on SSP Overall disk I/O rates: 21 Low I/O rates = no problem Can go to higher than 24 but it s not Supported Medium I/O rate SSP = no problem May demand higher VIOS CPU + RAM Use VIOS part command to monitor them High or Extreme I/O rate = take care See the VIOS Installation Readme or my notes on it AIXpert blog: VIOS SSP phase6 New Readme Content SYSTEM (metadata) tier on SSD or Flash Monitor whole SSP disk I/O rates (see item 5)

22 VIOS part - checks continue to grow 22 SSP Details

23 VIOS part - checks continue to grow 23 SSP Details

24 2 Disaster Recovery 24 Available for a few years as DevWorks scripts Was at-your-own-risk Now Fully Supported On a site failure you can rebuild your SPP Mirror or remote copy SSP LUN s to other site (using SAN disk subsystem features) Backup SSP config with: viosbr -autobackup Run viosbr -dr to fix up config file to use alternative VIOS nodes, LUN disk names & LU to Virtual Machine mappings. viobr -restore from the fixed backup file New SSP running as on the original site

25 2 Disaster Recovery Check out the manuals for these viosbr options 25 viosbr -dr -clustername clustername -file FileName -type devtype -typeinputs name:value [,...] -repopvs list_of_disks [-db] viosbr -autobackup {start stop status} [ -type {cluster node} ] viosbr -autobackup save

26 Phase 6 RAS: Cluster snap 3a Cluster Wide Snap Automation It seems every PMR s first response from support is: Can we have a snap? Capturing 16 (or now 24) VIOS snaps is... tricky 26 clffdc collects snap data from every node in the SSP cluster Single cluster snapshot (csnap), compressed tar, time co-ordinated See manual pages for details Example: all data and priority=medium As padmin: clffdc -c FULL -p 2 Saves to /home/ios/logs/ssp_ffdc/ snap_ _090336_by_full_med_c33.tar.gz c33 co-ord counter Expect LARGE files so make /home LARGE

27 Phase 6 RAS: Asymmetric Network Handling 3b New internal algorithm Normally, a managing node decides who is in the cluster, who gets expelled & who can join Rare condition: cluster manager has a partial network issue i.e. can communicate with some nodes but not all nodes [asymmetric] 27 The managing node is one of the VIOS & moves around as VIO Servers start & stop Now the manager node double checks if the good nodes can talk to the missing nodes Result: during flaky network issues, we get fewer unnecessary expelled nodes = SSP stability While you fix the network.

28 Phase 6 RAS: Lease by Clock Tick 28 3c Lease by Clock Tick The SSP VIOS s heartbeat each other to spot an unresponsive node & eventually expel it from the cluster When the VIOS returns it needs to catch up on SSP config and LU meta data, so its information is current In the past: If a user changes the time/date/zone it looks like a massive time jump = data is very out of date & forces an expel & rejoin You had to know to offline the VIOS & client LU s using: clstartstop -stop ; change date+time; clstartstop - start Once at VIOS st service pack you can change the date time at any time

29 4) lu -list -attr provisioned=<true/false> 29 If you say mapped when you read the word provisioned you can work out what this does! $ lu -list -attr provisioned=false Not mapped to any VM POOL_NAME: spiral TIER_NAME: SYSTEM LU_NAME SIZE(MB) UNUSED(MB) UDID test c043c90a91d434178a test efe7e54f79af7af67 test b cebd7357bd658 $ lu -list -attr provisioned=true is mapped to a VM POOL_NAME: spiral TIER_NAME: SYSTEM LU_NAME SIZE(MB) UNUSED(MB) UDID test de85f8af711f93a7a288 test ec547808deeba80398 $ Unfortunately, it does not say where test3 or test 5 are mounted later nmap

30 5) HMC SSP on the new Enhanced+ User GUI 30 DEMO

31 5) HMC SSP on the new Enhanced+ User GUI 31

32 6) HMC REST API for SSP performance stats 32 Is you SSP used lightly, moderate or hammered? Difficult to overview SSP I/O stats nmon from 24 VIOSs = hard work to merge! Same LUN has different hdisknn on each VIOS VIOS might be doing non-ssp disk I/O DEMO

33 6) HMC REST API for SSP performance stats HMC POWER8 VIOS Sysadmin home Server Linux or AIX & python v3 HMC interactions via REST API 1. Logon put 2. Preferences get XML 3. Switch on stats post XML 4. Request filenames get XML 5. Request files get XML 6. Files in JSON (50MB!) 7. Reformat into webpage Googlechart.html/Javascript

34 6) HMC REST API for SSP performance stats 34 POWER8 VIOS line Python script to handle XML and JSON 2. HMC can provide 3 data types 1. Raw painful to use (deltas / seconds) 2. Processes last 2+ hours every 5 minutes 3. Aggregated: min, max, averages for different capture rates Also can limit by date/time or row count 3. JSON include five levels of detail: Whole SSP VIOS node Tier Failgrp Individual disks 4. Stats size+free, read + write: IOPS, KB/s, service-times, error, timeouts 5. Outputs CSV file the processed but simple Ksh to generate the graph webpage.

35 6) HMC REST API for SSP performance stats 35

36 6) HMC REST API for SSP VIOS level stats 36

37 Are you interested in trying this 37 I am willing to help you (if I get sample data) AIXpert Blog entry _Storage_Pool_I_O_Graphs_via_the_HMC_REST_API Short Term Issues: Blog not finished yet = just a few hints and graphs. Plan to finish this tomorrow or Monday 27 th Feb 2017 But there are a few teething problems at the moment! Some of the numbers are not right SSP Developers are working on this & hopefully resolved in the next few days/weeks. When the fixes are available, I will add the details to the Blog.

38 Five New Useful SSP commands from Nigel 38

39 New SSP commands from Nigel 39 ncluster status of all VIOS nlu improved lu replacement npool storage pool use nmap finds if a lu is online (mapped) on any VIOS nslim copy a fat LU backup to a now THIN LU Hands-up how many of you have read this AIXpert Blog Shared Storage Pools Hands-On Fun with Virtual Disks (LU) by Example Storage_Pools_Hands_On_Fun_with_Virtual_Disks_LU_by_Example DEMO

40 ncluster Check the good status of all VIOS? 40 $ ncluster No State Repos Pool Role ---Upgrade-Status--- Node-Name 1 OK OK OK DBN ON_LEVEL bronzevios1.ibm.com 2 OK OK OK ON_LEVEL silvervios1.ibm.com 3 OK OK OK ON_LEVEL goldvios1.ibm.com 4 OK OK OK ON_LEVEL orangevios1.ibm.com 5 OK OK OK ON_LEVEL redvios1.ibm.com Can take 10 seconds run Ksh, 2 lines based on: cluster -status -verbose UP_LEVEL means not yet all VOIS s on higher ioslevel DBN= database node the one that writes to the repository

41 nlu - improved lu replacement, format, ordered 41 $ nlu SizeMB UsedMB Used% Type Tier Name % THIN SYSTEM AIX735_b % THICK SYSTEM JUNK % THIN SYSTEM blue_backupvg % THIN SYSTEM blue_rootvg % THIN SYSTEM blue_scratchvg % THIN SYSTEM blue_webvg % THIN SYSTEM emerald % THIN SYSTEM emerald % THICK SYSTEM orange5a % THIN SYSTEM purple3boot % THIN SYSTEM purple3files % THIN SYSTEM ruby32boot % THIN SYSTEM ruby32data % THIN SYSTEM vm100 Removed hex ID numbers & mixed in snapshots You can re-order by column name

42 nlu - improved lu replacement, format, ordered $ nlu usedmb SizeMB UsedMB Used% Type Tier Name % THIN SYSTEM vm % THIN SYSTEM vm91_mirror % THIN SYSTEM vm61c % THIN SYSTEM vm % THIN SYSTEM vm61a % THIN SYSTEM AIX735_b % THIN SYSTEM emerald % THIN SYSTEM vm18boot % THIN SYSTEM vm23a % THIN SYSTEM vm24a % THIN SYSTEM purple3boot % THIN SYSTEM ruby32boot % THIN SYSTEM vm27b % THIN SYSTEM vm21a lines of ksh, based on lu -list field nlu like lu and reorder on a column nlu [-sizemb -usedmb -used -type -tier -name (default)]

43 nmap - Is a LU mapped to a vhost somewhere 43 Ksh, 30 lines uses clcmd to run lsmap cluster wide $ nmap -h Nigel's nmap to find if a LU (virtual disk) is mapped anywhere on the SSP to a LPAR/VM nmap lu-name nmap ALL $ nmap vm21 Seach the SSP for vm21 NODE diamondvios2.aixncc.uk.ibm.com NODE diamondvios1.aixncc.uk.ibm.com NODE greenvios2.aixncc.uk.ibm.com NODE greenvios1.aixncc.uk.ibm.com NODE limevios2.aixncc.uk.ibm.com vhost6:u a v-v4-c8:vm21a.5cc155a78dbc3d1b a70ec0788 NODE limevios1.aixncc.uk.ibm.com vhost7:u a v-v1-c6:vm21a.5cc155a78dbc3d1b a70ec0788 NODE purplevio2.aixncc.uk.ibm.com NODE purplevio1.aixncc.uk.ibm.com NODE rubyvios2.aixncc.uk.ibm.com NODE emeraldvios2.aixncc.uk.ibm.com NODE emeraldvios1.aixncc.uk.ibm.com NODE rubyvios1.aixncc.uk.ibm.com NODE indigovios1.aixncc.uk.ibm.com

44 npool - storage pool use $ npool name = globular Pool Pacific Pool-Size= MB Pool-Used= MB =64.94% Pool-Free= MB =35.06% 44 Allocated to client VMs = MB Allocated compared to Pool=117.46% Used to Allocate Ratio =55.29% Overcommit= MB Ksh, 9 lines, using cluster & lssp No ntier command better to use: tier -list -verbose

45 Let talk about Sparse Files 45 Hands up who knows about then? Open a file A, write 4K, lseek() to 500 KB, write 4k, close it Then how big is the file A? Zero all through here 500 KB 4KB Answers: 500 KB +4 KB = 504 KB 4 KB + 4 KB = 8 KB Make a copy: cp A B How big is file B? Answers: 500 KB +4 KB = 504KB 4 KB + 4 KB = 8 KB 4KB SSP Thick provisioned LU is a full fat file = every block allocated SSP Thin provisioned LU is a sparse file but at a 1 MB chunk size

46 nslim - copy a fat LU backup to a now THIN LU 46 C code, 96 lines #./nslim -h Usage:./nslim (v3) is a filter style program using stdin & stdout It will thinly write a file (only copy non-zero blocks) It uses 1MB blocks If a block is zero-filled then it is skipped using lseek() If a block has data then it will write() the block unchanged Example:./nslim <AIX.lu >SSP-LU-name Flags: -v for verbose output for every block you get a W=write or.=lseek on stderr./nslim -v <AIX.lu >SSP-LU-name this gives you visual feedback on progress -t like verbose but does NOT actually write anything to stdout this lets you passively see the mix of used and unused blocks./nslim -t <AIX.lu -h or -? outputs this helpful message! Warning: Get the redirection wrong and you will destroy your LU data

47 nslim - copy a fat LU backup to a now THIN LU Examples 47 # nslim -v <$SSP/VOL1/old99.* >$SSP/VOL1/new42.* #./nslim -t <$SSP/VOL1/new77.* Processing W......W...WWWWWWWWW...W WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW.WWWWWWWWWWW...WWWWWWWWW...WWWWWWWWWW...WW..WWWWWWWWWWWWWWWWWWWWWWWW WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW.

48 nslim v4 outputs 1 line per GB 48 # /home/padmin/nslim_v4 -V <TEMP32G.6bfd6b0dd9c975c8cae0f69bf >vm99.32bcf97e86fad24f9dca0400cebe06d3 Counting 1 Written= 980 Skipped= 44 2 Written= 989 Skipped= 35 3 Written= 407 Skipped= Written= 4 Skipped= Written= 881 Skipped= Written= 393 Skipped= Written= 106 Skipped= Written= 0 Skipped= Written= 87 Skipped= Written= 0 Skipped= Written= 149 Skipped= Written= 0 Skipped= Written= 248 Skipped= Written= 0 Skipped= Written= 102 Skipped= Written= 0 Skipped= Written= 279 Skipped= Written= 0 Skipped= Written= 98 Skipped= Written= 0 Skipped= Written= 216 Skipped= Written= 0 Skipped= Written= 7 Skipped= Written= 1 Skipped=1023 Percent Written=20.27% Skipped=79.73% Done

49 49 Under the covers Shhh! This is bit is secret! Loads more info in the AIXpert blog

50 What is that VIOS filesystem about? 50 $ df Filesystem 512-blocks Free %Used Iused %Iused Mounted on /dev/hd % % / /dev/hd % % /usr /dev/hd9var % % /var /dev/hd % 119 1% /tmp /dev/vmlibrary % 6 1% /var/vio/vmlibrary /dev/hd % 93 1% /home /dev/hd11admin % 5 1% /admin /proc /proc /dev/hd10opt % % /opt /dev/livedump % 4 1% /var/adm/ras/livedump /ahafs % /aha /var/vio/ssp/spiral/d_e_f_a_u_l_t_ % - - Never ever create a file in /var/vio/ssp/ Treat it like /dev!!!

51 Backup LU from VIOS 51 $ df Filesystem 512-blocks Free %Used Iused %Iused Mounted on /dev/hd % % / /dev/hd % % /usr /dev/hd9var % % /var /dev/hd % 386 1% /tmp /dev/hd % % /home /dev/hd11admin % 5 1% /admin /proc /proc /dev/hd10opt % % /opt /dev/livedump % 4 1% /var/adm/ras/livedump /dev/vmlibrary % 8 1% /var/vio/vmlibrary /dev/fslv % 7 1% /scratch /ahafs % /aha /var/vio/ssp/stellar/d_e_f_a_u_l_t_ % - - /var/vio/ssp/stellar/d_e_f_a_u_l_t_ # cd /var/vio/ssp/stellar/d_e_f_a_u_l_t_ # ls -l total 24 drwxr-xr-x 2 root system 4096 Aug 21 13:43 IM drwxr-xr-x 7 root system 512 Jun 06 21:47 VIOSCFG drwxr-xr-x 2 root system 8192 Oct 03 17:14 VOL1 # PowerVC Deploy Images Dragons! LUfile s & hidden snapshots

52 # ls s /var/vio/ssp/stellar/d_e_f_a_u_l_t_061310/vol1 total bronze2a.9e2d5cb119e0ee278be433fc39072e64 4.bronze3a fbcfb2148a08869a bronze4a dd6f bbfabc497b104 4.bronze5a.f98b27fc9f947484ff4a66757e764f28 4.bronze6a.1488d ed51495e3c70bcc6ef57 4.fred.63a f9f7ffdd851041f4bd1af 4.volume-ScratchDisk.2c4bfdae192bdecb196399a0e9688c24 4.volume-boot-8203E4A_10E0A11-vm613cb6f0e0df0841ecbfaff86f2cc385f volume-boot-8203E4A_10E0A11-vm63a44d94e4e1034b45b1da9c75056c6bd volume-boot-8203E4A_10E0A11-vm8560dc473b76fd42a78fe26fb2c6a02e volume-boot-8203E4A_10E0A31-VM64e7f5cbaeb b2ff690daf6c806a... 4.volume-boot-8203E4A_10E0A31-vm f28a3463cb124678d0640ae5a... 4.volume-boot-8203E4A_10E0A31-vm82a64fc3ca9a91492b8a000c27d20c5b volume-vm63_backup.b c0ec90529c58bc930460d50e bronze2a.9e2d5cb119e0ee278be433fc39072e bronze3a fbcfb2148a08869a bronze4a dd6f bbfabc497b bronze5a.f98b27fc9f947484ff4a66757e764f bronze6a.1488d ed51495e3c70bcc6ef57 0 fred.63a f9f7ffdd851041f4bd1af 0 volume-scratchdisk.2c4bfdae192bdecb196399a0e9688c24 Start with. = Meta data Never ever touch these! Regular LU names volume-boot-8203e4a_10e0a11-vm613cb6f0e0df0841ecbfaff86f2cc385f volume-boot-8203e4a_10e0a11-vm63a44d94e4e1034b45b1da9c75056c6bd volume-boot-8203e4a_10e0a11-vm8560dc473b76fd42a78fe26fb2c6a02e volume-boot-8203e4a_10e0a31-vm64e7f5cbaeb b2ff690daf6c806a volume-boot-8203e4a_10e0a31-vm f28a3463cb124678d0640ae5a volume-boot-8203e4a_10e0a31-vm82a64fc3ca9a91492b8a000c27d20c5b volume-vm63_backup.b c0ec90529c58bc930460d50e 52 PowerVC horrid LU names! Raw LU files some Thin and some Thick Provisioned

53 Nine useful internal SSP operations 53 1) Rename a Thick Provisioned LU Stop the VM then lu -create to make new LU virtual disk with the new name dd if=oldlufile of=newlufile bs=1m lu -unmap the old LU then lu -map the new LU and restart 2) Rename a Thin Provisioned LU Stop the VM then lu -create to make new LU virtual disk with the new name nslim <oldlufile >newlufile lu -unmap the old LU then lu -map the new LU and restart 3) Backup a virtual disk LU Stop the VM dd if=lufile of=/tmp/mylu bs=1m Restart the VM LUfile is the file from = /var/vio/ssp/sspname/d_e_f_a_u_l_t_061310/vol1

54 Nine useful internal SSP operations 4) Recover a previous Thick Provisioned Backup Stop the VM dd if=/tmp/mylu of=lufile bs=1m Restart the VM 54 5) Recover a previous Thin Provisioned Backup Stop the VM lu -unmap -lu LUname lu -remove -lu Luname lu -create -lu newlu nslim </tmp/lubackup >newlu Restart the VM 6) Live Backup a point in time safe LU using a SSP snapshot -create -lu Luname File hidden from ls output dd if=luname@snapshotname of=/temp/backup snapshot -delete LUfile is the file from = /var/vio/ssp/sspname/d_e_f_a_u_l_t_061310/vol1 DEMO

55 Nine useful internal SSP operations 55 7) Have a look at the 1MB blocks in use within a Thin Provisioned LU nslim -t <LUfile 8) Slimming down a Thin Provisioned LU that got too Thick (AIX only) Reduce the file-systems to minimum size: chfs -a size=-1g /home (run many times) Create new max size LV dd if=/dev/zero of=/dev/lv bs=1m Remove the LV Stop the VM dd if=lufile of=/tmp/mylu bs=1m nslim </tmp/mylu >LUfile Restart VM and remove the /tmp/mylu 9) To move a Thin Provisioned LU from a remote SSP LU to a local SSP scp root@redvios1:$sspremote/vol1/lufile $SSPlocal/VOL1/LUfile LUfile is the file from = /var/vio/ssp/sspname/d_e_f_a_u_l_t_061310/vol1

56 Are you keeping up to date? 56 mr_nmon on twitter Only used to POWER / AIX technical content, hints, tips and links 150 techie hands-on videos on YouTube at AIXpert Blog Lots of mini articles & thoughts Also:

HMC 860 Enhanced+ & Classic is DEAD

HMC 860 Enhanced+ & Classic is DEAD HMC 860 Enhanced+ & Classic is DEAD Nigel Griffiths Power Systems Advanced Technology Support IBM Europe 2016 IBM Corporation HMC Classic User Interface 2 Copyright IBM Corporation 2011 1 HMC Classic User

More information

VIOS FP25_SP05

VIOS FP25_SP05 VIOS 2.2.1.7 FP25_SP05 Contributed by Michael Felt Package information PACKAGE: Update Release 2.2.1.7 IOSLEVEL: 2.2.1.7 VIOS level is NIM Master level must be equal to or higher than Service Pack 05 for

More information

viosupgrade command from VIOS Non-NIM environment Chris Gibson, IBM Systems Lab Services (Sept 6 th, 2018). Rough Draft.

viosupgrade command from VIOS Non-NIM environment Chris Gibson, IBM Systems Lab Services (Sept 6 th, 2018). Rough Draft. viosupgrade command from VIOS Non-NIM environment Chris Gibson, IBM Systems Lab Services (Sept 6 th, 2018). Rough Draft. NOTE: The following document describes testing of ESP VIOS 3.1 code, pre-ga. In

More information

Power Systems with POWER8 Scale-out Technical Sales Skills V1

Power Systems with POWER8 Scale-out Technical Sales Skills V1 Power Systems with POWER8 Scale-out Technical Sales Skills V1 1. An ISV develops Linux based applications in their heterogeneous environment consisting of both IBM Power Systems and x86 servers. They are

More information

Advanced Virtual I/O Server Configurations. César Diniz Maciel Consulting IT Specialist IBM US

Advanced Virtual I/O Server Configurations. César Diniz Maciel Consulting IT Specialist IBM US Advanced Virtual I/O Server Configurations César Diniz Maciel Consulting IT Specialist IBM US Agenda Virtual Optical Devices, Virtual Optical Media, File-backed Devices Shared Ethernet Adapter (SEA) Failover

More information

June IBM Power Academy. IBM PowerVM memory virtualization. Luca Comparini STG Lab Services Europe IBM FR. June,13 th Dubai

June IBM Power Academy. IBM PowerVM memory virtualization. Luca Comparini STG Lab Services Europe IBM FR. June,13 th Dubai June 2012 @Dubai IBM Power Academy IBM PowerVM memory virtualization Luca Comparini STG Lab Services Europe IBM FR June,13 th 2012 @IBM Dubai Agenda How paging works Active Memory Sharing Active Memory

More information

41CO Operation and Maintaining PowerVM VIOS with IBM i

41CO Operation and Maintaining PowerVM VIOS with IBM i 41CO Operation and Maintaining PowerVM VIOS with IBM i Gary Konicek konicek@us.ibm.com IBM Lab Services Session ID: Agenda Key: 170299 41CO Fix Strategy before June 2015 Base releases: i.e. 2.2.1.0 i.e.

More information

Unit 8 System storage overview

Unit 8 System storage overview Unit 8 System storage overview Course materials may not be reproduced in whole or in part without the prior written permission of IBM. 5.1 Unit objectives After completing this unit, you should be able

More information

IBM SYSTEM POWER7. PowerVM. Jan Kristian Nielsen Erik Rex IBM Corporation

IBM SYSTEM POWER7. PowerVM. Jan Kristian Nielsen Erik Rex IBM Corporation IBM SYSTEM POWER7 PowerVM Jan Kristian Nielsen jankn@dk.ibm.com - +45 28803310 Erik Rex Rex@dk.ibm.com - +45 28803326 PowerVM: Virtualization Without Limits Reduces IT infrastructure costs Improves service

More information

AIX Power System Assessment

AIX Power System Assessment When conducting an AIX Power system assessment, we look at how CPU, Memory and Disk I/O are being consumed. This can assist in determining whether or not the system is sufficiently sized. An undersized

More information

IBM Systems Director VMControl

IBM Systems Director VMControl IBM Systems Director VMControl Glen Corneau Copyright IBM Corporation 2011 Materials may not be reproduced in whole or in part without the prior written permission of IBM. 5.3 Agenda > VMControl V2.3.1

More information

3.5.5 Creating client partitions

3.5.5 Creating client partitions Example 3-27 Logical partitions are mapped to two physical partitions $ lsvg -lv rootvg rootvg: LV NAME TYPE LPs PPs PVs LV STATE MOUNT POINT hd5 boot 1 2 2 closed/syncd N/A hd6 paging 4 8 2 open/syncd

More information

Virtualization Technical Support for AIX and Linux - v2

Virtualization Technical Support for AIX and Linux - v2 IBM 000-109 Virtualization Technical Support for AIX and Linux - v2 Version: 5.0 Topic 1, Volume A QUESTION NO: 1 An administrator is attempting to configure a new deployment of 56 POWER7 Blades across

More information

Virtualization Benefits IBM Corporation

Virtualization Benefits IBM Corporation Virtualization Benefits 1 Virtualization Benefits CPU Utilization 100 90 80 70 60 50 40 30 20 10 0 8:00 10:00 12:00 2:00 4:00 Time Purchased Peak Average Increase Utilization Non-virtualized servers often

More information

Mechanic v. Surgeon (photos from istockphoto.com)

Mechanic v. Surgeon (photos from istockphoto.com) 0 Mechanic v. Surgeon (photos from istockphoto.com) 1 2007: AIX Kernel hotpatch support available with AIX 6.1 2008: Ksplice Linux hotpatch support (based on MIT student s master s thesis) Stops all running

More information

Live Partition Mobility Update

Live Partition Mobility Update Power Systems ATS Live Partition Mobility Update Ron Barker Power Advanced Technical Sales Support Dallas, TX Agenda Why you should be planning for partition mobility What are your options? Which is best

More information

DAHA AKILLI BĐR DÜNYA ĐÇĐN BĐLGĐ ALTYAPILARIMIZI DEĞĐŞTĐRECEĞĐZ

DAHA AKILLI BĐR DÜNYA ĐÇĐN BĐLGĐ ALTYAPILARIMIZI DEĞĐŞTĐRECEĞĐZ Information Infrastructure Forum, Istanbul DAHA AKILLI BĐR DÜNYA ĐÇĐN BĐLGĐ ALTYAPILARIMIZI DEĞĐŞTĐRECEĞĐZ 2010 IBM Corporation Information Infrastructure Forum, Istanbul IBM XIV Veri Depolama Sistemleri

More information

EMC CLARiiON LUN Shrinking with Microsoft Exchange 2007

EMC CLARiiON LUN Shrinking with Microsoft Exchange 2007 EMC CLARiiON LUN Shrinking with Microsoft Exchange 2007 Applied Technology Abstract This white paper discusses the EMC CLARiiON LUN shrinking feature in detail. It captures the business benefits and advantages

More information

KillTest *KIJGT 3WCNKV[ $GVVGT 5GTXKEG Q&A NZZV ]]] QORRZKYZ IUS =K ULLKX LXKK [VJGZK YKX\OIK LUX UTK _KGX

KillTest *KIJGT 3WCNKV[ $GVVGT 5GTXKEG Q&A NZZV ]]] QORRZKYZ IUS =K ULLKX LXKK [VJGZK YKX\OIK LUX UTK _KGX KillTest Q&A Exam : 000-108 Title : Enterprise Technical Support for AIX and Linux -v2 Version : Demo 1 / 7 1.Which power reduction technology requires a software component in order to be activated? A.

More information

VIOS NextGen: Server & Storage Integration

VIOS NextGen: Server & Storage Integration IBM Power Systems Technical University October 18 22, 2010 Las Vegas, NV NextGen: Server & Storage Integration Session ID: VM19 PowerVM : Virtualization for IBM Power Systems Speaker Name: Bob Kovacs All

More information

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Administration Guide for 7.2 release June 2018 215-13169_A0 doccomments@netapp.com Table of Contents 3 Contents

More information

Vendor: IBM. Exam Code: C Exam Name: Enterprise Technical Support for AIX and Linux -v2. Version: Demo

Vendor: IBM. Exam Code: C Exam Name: Enterprise Technical Support for AIX and Linux -v2. Version: Demo Vendor: IBM Exam Code: C4040-108 Exam Name: Enterprise Technical Support for AIX and Linux -v2 Version: Demo QUESTION 1 Which power reduction technology requires a software component in order to be activated?

More information

Power Cloud for Administrators

Power Cloud for Administrators Power Cloud for Administrators Vess Natchev & Kyle Wurgler US Lab Services Power Cloud Team Tips for the Webinar Tweeting? Please use these tags: #IBMtraining @IBM @GlobalKnowledge Citrix Tech Support

More information

rsync link-dest Local, rotated, quick and useful backups!

rsync link-dest Local, rotated, quick and useful backups! rsync link-dest Local, rotated, quick and useful backups! Scope No complete scripts will be presented Just enough so that a competent scripter will be able to build what they need Unixes used: OpenBSD,

More information

Application and Partition Mobility

Application and Partition Mobility IBM System p Application and Mobility Francis COUGARD IBM Products and Solutions Support Center Montpellier Copyright IBM Corporation 2009 Index Application and Mobility Presentation Videocharger and DB2

More information

Warsaw. 11 th September 2018

Warsaw. 11 th September 2018 Warsaw 11 th September 2018 Dell EMC Unity & SC Series Midrange Storage Portfolio Overview Bartosz Charliński Senior System Engineer, Dell EMC The Dell EMC Midrange Family SC7020F SC5020F SC9000 SC5020

More information

Host PowerTools User Manual

Host PowerTools User Manual Host PowerTools 4.0 - User Manual Introduction to Host PowerTools......................................................................... 3 1 What is INFINIDAT Host PowerTools.................................................................

More information

COS 318: Operating Systems. File Systems. Topics. Evolved Data Center Storage Hierarchy. Traditional Data Center Storage Hierarchy

COS 318: Operating Systems. File Systems. Topics. Evolved Data Center Storage Hierarchy. Traditional Data Center Storage Hierarchy Topics COS 318: Operating Systems File Systems hierarchy File system abstraction File system operations File system protection 2 Traditional Data Center Hierarchy Evolved Data Center Hierarchy Clients

More information

<Insert Picture Here> Btrfs Filesystem

<Insert Picture Here> Btrfs Filesystem Btrfs Filesystem Chris Mason Btrfs Goals General purpose filesystem that scales to very large storage Feature focused, providing features other Linux filesystems cannot Administration

More information

TSM Paper Replicating TSM

TSM Paper Replicating TSM TSM Paper Replicating TSM (Primarily to enable faster time to recoverability using an alternative instance) Deon George, 23/02/2015 Index INDEX 2 PREFACE 3 BACKGROUND 3 OBJECTIVE 4 AVAILABLE COPY DATA

More information

Experiences with VIOS support for IBM i

Experiences with VIOS support for IBM i Experiences with VIOS support for IBM i Pete Stephen, Power Systems / AIX Architect Sirius Computer Solutions Pete.Stephen@siriuscom.com Agenda VIO overview Virtualization Trends. PowerVM and how do I

More information

Power Systems High Availability & Disaster Recovery

Power Systems High Availability & Disaster Recovery Power Systems High Availability & Disaster Recovery Solutions Comparison of various HA & DR solutions for Power Systems Authors: Carl Burnett, Joe Cropper, Ravi Shankar Table of Contents 1 Abstract...

More information

Planning for Virtualization on System P

Planning for Virtualization on System P Planning for Virtualization on System P Jaqui Lynch Systems Architect Mainline Information Systems Jaqui.lynch@mainline.com com http://www.circle4.com/papers/powervm-performance-may09.pdf http://mainline.com/knowledgecenter

More information

Storage and File System

Storage and File System COS 318: Operating Systems Storage and File System Andy Bavier Computer Science Department Princeton University http://www.cs.princeton.edu/courses/archive/fall10/cos318/ Topics Storage hierarchy File

More information

SAN Storage Array Workbook September 11, 2012

SAN Storage Array Workbook September 11, 2012 Page 1 of 9 The following are questions to be asked regarding acquiring SAN Storage Arrays. Some of the questions need to be filled in for the specific environment where the storage system will be deployed

More information

Nové možnosti storage virtualizace s řešením IBM Storwize V7000

Nové možnosti storage virtualizace s řešením IBM Storwize V7000 Nové možnosti storage virtualizace s řešením IBM Storwize V7000 A new generation of midrange storage Rudolf Hruška Information Infrastructure Leader IBM Systems & Technology Group rudolf_hruska@cz.ibm.com

More information

A review of AIX Container Technology: with perspectives on. Docker Management Operations. Zeyuan Zhu. AIX Development Engineer

A review of AIX Container Technology: with perspectives on. Docker Management Operations. Zeyuan Zhu. AIX Development Engineer A review of AIX Container Technology: with perspectives on Docker Management Operations Zeyuan Zhu AIX Development Engineer In this paper, I'm going to give you an introduction to container technology,

More information

1Y0-A26 Citrix XenServer 6.0 Practice Exam

1Y0-A26 Citrix XenServer 6.0 Practice Exam 1Y0-A26 Citrix XenServer 6.0 Practice Exam Section 1: Implementing XenServer 1.1 Specific Task: Configure boot storage from SAN Objective: Given a scenario, determine how to configure options on the XenServer

More information

IBM Solutions Advanced Technical Support

IBM Solutions Advanced Technical Support DB2 and SAP Disaster Recovery using DS8300 Global Mirror IBM Solutions Advanced Technical Support Nasima Ahmad Chris Eisenmann Jean-Luc Degrenand Mark Gordon Mark Keimig Damir Rubic Version: 1.1 Date:

More information

Configuring Short RPO with Actifio StreamSnap and Dedup-Async Replication

Configuring Short RPO with Actifio StreamSnap and Dedup-Async Replication CDS and Sky Tech Brief Configuring Short RPO with Actifio StreamSnap and Dedup-Async Replication Actifio recommends using Dedup-Async Replication (DAR) for RPO of 4 hours or more and using StreamSnap for

More information

IBM Storwize V7000 with IBM PowerHA SystemMirror

IBM Storwize V7000 with IBM PowerHA SystemMirror IBM Storwize V7000 with IBM PowerHA SystemMirror Proof of concept and configuration Zane Russell IBM Systems and Technology Group ISV Enablement March 2011 Copyright IBM Corporation, 2011. Abstract...

More information

The Fastest And Most Efficient Block Storage Software (SDS)

The Fastest And Most Efficient Block Storage Software (SDS) The Fastest And Most Efficient Block Storage Software (SDS) StorPool: Product Summary 1. Advanced Block-level Software Defined Storage, SDS (SDS 2.0) Fully distributed, scale-out, online changes of everything,

More information

Exam : Title : High-End Disk for Open Systems V2. Version : DEMO

Exam : Title : High-End Disk for Open Systems V2. Version : DEMO Exam : 000-968 Title : High-End Disk for Open Systems V2 Version : DEMO 1.An international company has a heterogeneous IBM storage environment with two IBM DS8700 systems in a Metro Mirror relationship.

More information

JPexam. 最新の IT 認定試験資料のプロバイダ IT 認証であなたのキャリアを進めます

JPexam.   最新の IT 認定試験資料のプロバイダ IT 認証であなたのキャリアを進めます JPexam 最新の IT 認定試験資料のプロバイダ http://www.jpexam.com IT 認証であなたのキャリアを進めます Exam : E20-885 Title : VNX Solutions Expert Exam for Implementation Engineers Vendor : EMC Version : DEMO Get Latest & Valid E20-885

More information

Best Practices. Deploying Optim Performance Manager in large scale environments. IBM Optim Performance Manager Extended Edition V4.1.0.

Best Practices. Deploying Optim Performance Manager in large scale environments. IBM Optim Performance Manager Extended Edition V4.1.0. IBM Optim Performance Manager Extended Edition V4.1.0.1 Best Practices Deploying Optim Performance Manager in large scale environments Ute Baumbach (bmb@de.ibm.com) Optim Performance Manager Development

More information

C exam. Number: C Passing Score: 800 Time Limit: 120 min IBM C IBM AIX Administration V1.

C exam. Number: C Passing Score: 800 Time Limit: 120 min IBM C IBM AIX Administration V1. C9010-022.exam Number: C9010-022 Passing Score: 800 Time Limit: 120 min IBM C9010-022 IBM AIX Administration V1 Exam A QUESTION 1 A customer has a virtualized system using Virtual I/O Server with multiple

More information

PowerVM simplification enhancements. PowerVM simplification enhancements. PowerVM infrastructure overview

PowerVM simplification enhancements. PowerVM simplification enhancements. PowerVM infrastructure overview PowerVM simplification enhancements PowerVM infrastructure overview IBM PowerVM is the virtualization solution that enables workload consolidation for AIX, IBM i, and Linux environments on IBM Power Systems

More information

Zadara Enterprise Storage in

Zadara Enterprise Storage in Zadara Enterprise Storage in Google Cloud Platform (GCP) Deployment Guide March 2017 Revision A 2011 2017 ZADARA Storage, Inc. All rights reserved. Zadara Storage / GCP - Deployment Guide Page 1 Contents

More information

Storage Profiles. Storage Profiles. Storage Profiles, page 12

Storage Profiles. Storage Profiles. Storage Profiles, page 12 , page 1 Disk Groups and Disk Group Configuration Policies, page 2 RAID Levels, page 6 Automatic Disk Selection, page 7 Supported LUN Modifications, page 8 Unsupported LUN Modifications, page 8 Disk Insertion

More information

Virtualizing Oracle on VMware

Virtualizing Oracle on VMware Virtualizing Oracle on VMware Sudhansu Pati, VCP Certified 4/20/2012 2011 VMware Inc. All rights reserved Agenda Introduction Oracle Databases on VMware Key Benefits Performance, Support, and Licensing

More information

EMC Celerra Virtual Provisioned Storage

EMC Celerra Virtual Provisioned Storage A Detailed Review Abstract This white paper covers the use of virtual storage provisioning within the EMC Celerra storage system. It focuses on virtual provisioning functionality at several levels including

More information

IBM EXAM QUESTIONS & ANSWERS

IBM EXAM QUESTIONS & ANSWERS IBM 000-106 EXAM QUESTIONS & ANSWERS Number: 000-106 Passing Score: 800 Time Limit: 120 min File Version: 38.8 http://www.gratisexam.com/ IBM 000-106 EXAM QUESTIONS & ANSWERS Exam Name: Power Systems with

More information

Dell Fluid Data solutions. Powerful self-optimized enterprise storage. Dell Compellent Storage Center: Designed for business results

Dell Fluid Data solutions. Powerful self-optimized enterprise storage. Dell Compellent Storage Center: Designed for business results Dell Fluid Data solutions Powerful self-optimized enterprise storage Dell Compellent Storage Center: Designed for business results The Dell difference: Efficiency designed to drive down your total cost

More information

Power8 Migration. Hugo Jaspers Common Nederland September 25, 2017

Power8 Migration. Hugo Jaspers Common Nederland September 25, 2017 Power8 Migration Hugo Jaspers Common Nederland September 25, 2017 Content How we got to Power7 and EMC VMAX The design and creation of our own benchmark test Why we wanted to discontinue EMC VMAX Why we

More information

Configuring Storage Profiles

Configuring Storage Profiles This part contains the following chapters: Storage Profiles, page 1 Disk Groups and Disk Group Configuration Policies, page 2 RAID Levels, page 3 Automatic Disk Selection, page 4 Supported LUN Modifications,

More information

Linux Files and the File System

Linux Files and the File System Linux Files and the File System 1. Files a. Overview A simple description of the UNIX system, also applicable to Linux, is this: "On a UNIX system, everything is a file; if something is not a file, it

More information

Performance Best Practices Paper for IBM Tivoli Directory Integrator v6.1 and v6.1.1

Performance Best Practices Paper for IBM Tivoli Directory Integrator v6.1 and v6.1.1 Performance Best Practices Paper for IBM Tivoli Directory Integrator v6.1 and v6.1.1 version 1.0 July, 2007 Table of Contents 1. Introduction...3 2. Best practices...3 2.1 Preparing the solution environment...3

More information

Dell EMC Unity Family

Dell EMC Unity Family Dell EMC Unity Family Version 4.4 Configuring and managing LUNs H16814 02 Copyright 2018 Dell Inc. or its subsidiaries. All rights reserved. Published June 2018 Dell believes the information in this publication

More information

PRESENTATION TITLE GOES HERE

PRESENTATION TITLE GOES HERE Performance Basics PRESENTATION TITLE GOES HERE Leah Schoeb, Member of SNIA Technical Council SNIA EmeraldTM Training SNIA Emerald Power Efficiency Measurement Specification, for use in EPA ENERGY STAR

More information

Mission-Critical Lustre at Santos. Adam Fox, Lustre User Group 2016

Mission-Critical Lustre at Santos. Adam Fox, Lustre User Group 2016 Mission-Critical Lustre at Santos Adam Fox, Lustre User Group 2016 About Santos One of the leading oil and gas producers in APAC Founded in 1954 South Australia Northern Territory Oil Search Cooper Basin

More information

IBM Tivoli Storage Manager for HP-UX Version Installation Guide IBM

IBM Tivoli Storage Manager for HP-UX Version Installation Guide IBM IBM Tivoli Storage Manager for HP-UX Version 7.1.4 Installation Guide IBM IBM Tivoli Storage Manager for HP-UX Version 7.1.4 Installation Guide IBM Note: Before you use this information and the product

More information

EMC Backup and Recovery for Microsoft Exchange 2007 SP1. Enabled by EMC CLARiiON CX4-120, Replication Manager, and VMware ESX Server 3.

EMC Backup and Recovery for Microsoft Exchange 2007 SP1. Enabled by EMC CLARiiON CX4-120, Replication Manager, and VMware ESX Server 3. EMC Backup and Recovery for Microsoft Exchange 2007 SP1 Enabled by EMC CLARiiON CX4-120, Replication Manager, and VMware ESX Server 3.5 using iscsi Reference Architecture Copyright 2009 EMC Corporation.

More information

IBM SmartCloud Entry. Administrator Guide 2.3

IBM SmartCloud Entry. Administrator Guide 2.3 IBM SmartCloud Entry Administrator Guide 2.3 IBM SmartCloud Entry Administrator Guide 2.3 Note Before using this information and the product it supports, read the information in Notices on page 115. Second

More information

Netapp Exam NS0-157 NetApp Certified Data Administrator, Clustered Data ONTAP Version: 11.0 [ Total Questions: 302 ]

Netapp Exam NS0-157 NetApp Certified Data Administrator, Clustered Data ONTAP Version: 11.0 [ Total Questions: 302 ] s@lm@n Netapp Exam NS0-157 NetApp Certified Data Administrator, Clustered Data ONTAP Version: 11.0 [ Total Questions: 302 ] https://certkill.com Topic break down Topic No. of Questions Topic 1: Volume

More information

C Number: C Passing Score: 800 Time Limit: 120 min File Version: 5.0. IBM C Questions & Answers

C Number: C Passing Score: 800 Time Limit: 120 min File Version: 5.0. IBM C Questions & Answers C4040-251 Number: C4040-251 Passing Score: 800 Time Limit: 120 min File Version: 5.0 http://www.gratisexam.com/ IBM C4040-251 Questions & Answers Power Systems with POWER8 Scale-out Technical Sales Skills

More information

Virtual Server Agent for VMware VMware VADP Virtualization Architecture

Virtual Server Agent for VMware VMware VADP Virtualization Architecture Virtual Server Agent for VMware VMware VADP Virtualization Architecture Published On: 11/19/2013 V10 Service Pack 4A Page 1 of 18 VMware VADP Virtualization Architecture - Virtual Server Agent for VMware

More information

Hitachi HH Hitachi Data Systems Storage Architect-Hitachi NAS Platform.

Hitachi HH Hitachi Data Systems Storage Architect-Hitachi NAS Platform. Hitachi HH0-450 Hitachi Data Systems Storage Architect-Hitachi NAS Platform http://killexams.com/exam-detail/hh0-450 QUESTION: 104 You are asked to design a Hitachi NAS Platform solution with a requirement

More information

Live Partition Mobility

Live Partition Mobility Live Partition Mobility Jaqui Lynch lynchj@forsythe.com Presentation at: http://www.circle4.com/forsythe/lpm2014.pdf 1 1 Why Live Partition Mobility? LPM LIVE PARTITION MOBILITY Uses Server Consolidation

More information

IBM Exam C IBM Storwize V7000 Implementation V1 Version: 6.0 [ Total Questions: 78 ]

IBM Exam C IBM Storwize V7000 Implementation V1 Version: 6.0 [ Total Questions: 78 ] s@lm@n IBM Exam C4090-457 IBM Storwize V7000 Implementation V1 Version: 6.0 [ Total Questions: 78 ] Question No : 1 How many days can an external virtualization license be used for migration before incurring

More information

IA L16 - Hands-On Lab Hands on with Instant Backup and Recovery Features of NetBackup 7.6 for VMware

IA L16 - Hands-On Lab Hands on with Instant Backup and Recovery Features of NetBackup 7.6 for VMware IA L16 - Hands-On Lab Hands on with Instant Backup and Recovery Features of NetBackup 7.6 for VMware Description NetBackup 7.6 offers terrific new technologies that provide faster VMware backups and restores

More information

SRM Evaluation Guide First Published On: Last Updated On:

SRM Evaluation Guide First Published On: Last Updated On: First Published On: 12-24-2016 Last Updated On: 04-17-2018 1 Table of Contents 1. Introduction 1.1.Overview 1.2.Terminology 1.3.About This Evaluation Guide 2. Requirements 2.1.Overview 3. Evaluation Workflow

More information

Format Hard Drive Using Windows 7 Recovery Disk

Format Hard Drive Using Windows 7 Recovery Disk Format Hard Drive Using Windows 7 Recovery Disk Jun 8, 2015. If it's not possible to create a recovery disk using this method, is it possible to backup Hey guys, I'm looking to format my hard-drive and

More information

Power Systems with POWER7 and AIX Technical Sales

Power Systems with POWER7 and AIX Technical Sales Power Systems with POWER7 and AIX Technical Sales Number: 000-107 Passing Score: 800 Time Limit: 120 min File Version: 26.6 http://www.gratisexam.com/ IBM 000-107 EXAM QUESTIONS & ANSWERS Exam Name: Power

More information

Pick your own enablement

Pick your own enablement Pick your own enablement Business Partner version April 2016 Pick Your Own Enablement Number of participants and : The number of required voucher indicated is per session, not per participant. Skills from

More information

VMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS

VMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS VMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS A detailed overview of integration points and new storage features of vsphere 5.0 with EMC VNX platforms EMC Solutions

More information

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Workflow Guide for 7.2 release July 2018 215-13170_B0 doccomments@netapp.com Table of Contents 3 Contents Deciding

More information

Installing and Upgrading Cisco Network Registrar Virtual Appliance

Installing and Upgrading Cisco Network Registrar Virtual Appliance CHAPTER 3 Installing and Upgrading Cisco Network Registrar Virtual Appliance The Cisco Network Registrar virtual appliance includes all the functionality available in a version of Cisco Network Registrar

More information

StorMagic SvSAN: A virtual SAN made simple

StorMagic SvSAN: A virtual SAN made simple Data Sheet StorMagic SvSAN: A virtual SAN made simple StorMagic SvSAN SvSAN is a software-defined storage solution designed to run on two or more servers. It is uniquely architected with the combination

More information

Clustered Data ONTAP 8.2

Clustered Data ONTAP 8.2 Updated for 8.2.1 Clustered Data ONTAP 8.2 SAN Administration Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888)

More information

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Administration Guide for 7.1 release January 2018 215-12648_B0 doccomments@netapp.com Table of Contents 3 Contents

More information

<Insert Picture Here> Filesystem Features and Performance

<Insert Picture Here> Filesystem Features and Performance Filesystem Features and Performance Chris Mason Filesystems XFS Well established and stable Highly scalable under many workloads Can be slower in metadata intensive workloads Often

More information

ECS. Monitoring Guide. Version 3.2.x.x

ECS. Monitoring Guide. Version 3.2.x.x ECS Version 3.2.x.x Monitoring Guide 302-004-492 03 Copyright 2018 Dell Inc. or its subsidiaries. All rights reserved. Published June 2018 Dell believes the information in this publication is accurate

More information

Hitachi Dynamic Provisioning The Unofficial Best Practice Guide

Hitachi Dynamic Provisioning The Unofficial Best Practice Guide Hitachi Dynamic Provisioning The Unofficial Best Practice Guide V1.3 1 Contents 1. Introduction 2. Pool Pre-requisites and Restrictions 3. Pool Performance 4. DP-VOL size recommendations 5. Other Considerations

More information

NetApp Solutions for Oracle

NetApp Solutions for Oracle NetApp Solutions for Oracle for BCCServices HROUG, Rovinj Oct. 19th 2007 Bernd Dultinger Sales Manager Eastern Europe Agenda NetApp and Oracle Partnership NetApp and Oracle Highlights NetApp Solutions

More information

Server Virtualization and Optimization at HSBC. John Gibson Chief Technical Specialist HSBC Bank plc

Server Virtualization and Optimization at HSBC. John Gibson Chief Technical Specialist HSBC Bank plc Server Virtualization and Optimization at HSBC John Gibson Chief Technical Specialist HSBC Bank plc Background Over 5,500 Windows servers in the last 6 years. Historically, Windows technology dictated

More information

Chapter 10: Mass-Storage Systems. Operating System Concepts 9 th Edition

Chapter 10: Mass-Storage Systems. Operating System Concepts 9 th Edition Chapter 10: Mass-Storage Systems Silberschatz, Galvin and Gagne 2013 Chapter 10: Mass-Storage Systems Overview of Mass Storage Structure Disk Structure Disk Attachment Disk Scheduling Disk Management Swap-Space

More information

Database Services at CERN with Oracle 10g RAC and ASM on Commodity HW

Database Services at CERN with Oracle 10g RAC and ASM on Commodity HW Database Services at CERN with Oracle 10g RAC and ASM on Commodity HW UKOUG RAC SIG Meeting London, October 24 th, 2006 Luca Canali, CERN IT CH-1211 LCGenève 23 Outline Oracle at CERN Architecture of CERN

More information

IBM V7000 Unified R1.4.2 Asynchronous Replication Performance Reference Guide

IBM V7000 Unified R1.4.2 Asynchronous Replication Performance Reference Guide V7 Unified Asynchronous Replication Performance Reference Guide IBM V7 Unified R1.4.2 Asynchronous Replication Performance Reference Guide Document Version 1. SONAS / V7 Unified Asynchronous Replication

More information

Performing Administrative Tasks

Performing Administrative Tasks This chapter describes how to perform administrative tasks using Cisco CMX. Users who are assigned administration privileges can perform administrative tasks. Cisco CMX User Accounts, page 1 Backing Up

More information

White Paper. EonStor GS Family Best Practices Guide. Version: 1.1 Updated: Apr., 2018

White Paper. EonStor GS Family Best Practices Guide. Version: 1.1 Updated: Apr., 2018 EonStor GS Family Best Practices Guide White Paper Version: 1.1 Updated: Apr., 2018 Abstract: This guide provides recommendations of best practices for installation and configuration to meet customer performance

More information

VMware vstorage APIs FOR ARRAY INTEGRATION WITH EMC VNX SERIES FOR SAN

VMware vstorage APIs FOR ARRAY INTEGRATION WITH EMC VNX SERIES FOR SAN White Paper VMware vstorage APIs FOR ARRAY INTEGRATION WITH EMC VNX SERIES FOR SAN Benefits of EMC VNX for Block Integration with VMware VAAI EMC SOLUTIONS GROUP Abstract This white paper highlights the

More information

VMware with CLARiiON. Sheetal Kochavara

VMware with CLARiiON. Sheetal Kochavara VMware with CLARiiON Sheetal Kochavara Agenda Overview of CLARiiON hardware and software products Integration of CLARiiON with VMware Use Cases of CLARiiON replication software with VMware EMC CLARiiON

More information

IBM C IBM AIX Administration V1. Download Full Version :

IBM C IBM AIX Administration V1. Download Full Version : IBM C9010-022 IBM AIX Administration V1 Download Full Version : http://killexams.com/pass4sure/exam-detail/c9010-022 QUESTION: 251 Consider the following screen capture. The administrator needs to add

More information

Infrastructure Tuning

Infrastructure Tuning Infrastructure Tuning For SQL Server Performance SQL PASS Performance Virtual Chapter 2014.07.24 About David Klee @kleegeek davidklee.net gplus.to/kleegeek linked.com/a/davidaklee Specialties / Focus Areas

More information

Configuring Storage Profiles

Configuring Storage Profiles This part contains the following chapters: Storage Profiles, page 1 Disk Groups and Disk Group Configuration Policies, page 2 RAID Levels, page 3 Automatic Disk Selection, page 4 Supported LUN Modifications,

More information

Chapter 10 Protecting Virtual Environments

Chapter 10 Protecting Virtual Environments Chapter 10 Protecting Virtual Environments 164 - Protecting Virtual Environments As more datacenters move to virtualize their environments and the number of virtual machines and the physical hosts they

More information

BMC Capacity Optimization Extended Edition AIX Enhancements

BMC Capacity Optimization Extended Edition AIX Enhancements BMC Capacity Optimization Extended Edition 9.5.1 AIX Enhancements Support for AIX Active Memory Expansion (AME) mode Metrics displayed in BCO AIX PowerVM view for CPU and Memory Allocation Frame name,

More information

Addressing Data Management and IT Infrastructure Challenges in a SharePoint Environment. By Michael Noel

Addressing Data Management and IT Infrastructure Challenges in a SharePoint Environment. By Michael Noel Addressing Data Management and IT Infrastructure Challenges in a SharePoint Environment By Michael Noel Contents Data Management with SharePoint and Its Challenges...2 Addressing Infrastructure Sprawl

More information

Evaluating Cloud Storage Strategies. James Bottomley; CTO, Server Virtualization

Evaluating Cloud Storage Strategies. James Bottomley; CTO, Server Virtualization Evaluating Cloud Storage Strategies James Bottomley; CTO, Server Virtualization Introduction to Storage Attachments: - Local (Direct cheap) SAS, SATA - Remote (SAN, NAS expensive) FC net Types - Block

More information

Veritas Storage Foundation for Windows by Symantec

Veritas Storage Foundation for Windows by Symantec Veritas Storage Foundation for Windows by Symantec Advanced online storage management Data Sheet: Storage Management Overview Veritas Storage Foundation 6.0 for Windows brings advanced online storage management

More information