VIOS FP25_SP05
|
|
- Alban Fitzgerald
- 6 years ago
- Views:
Transcription
1 VIOS FP25_SP05 Contributed by Michael Felt Package information PACKAGE: Update Release IOSLEVEL: VIOS level is NIM Master level must be equal to or higher than Service Pack 05 for Update release AIX General package notes The VIOS update Release provides updates to Virtual I/O Server (VIOS) between and installations. Applying this package will upgrade the VIOS to the latest level, V Review the list of fixes included in Update Release To take full advantage of all the function available in the VIOS on IBM Systems based on POWER6 or POWER7 technology, it is necessary to be at the latest system firmware level. If a system firmware update is necessary, it is recommended that the firmware be updated before you upgrade the VIOS to V Microcode or system firmware downloads for Power Systems The VIOS update Release V includes the IVM code, but it will not be enabled on HMC-managed systems. V , like all VIOS Update Releases, can be applied to either HMC-managed or IVM-managed VIOS. Update Release V updates your VIOS partition to ioslevel V To determine if Update Release is already installed, run the following command from the VIOS command line: $ ioslevel
2 If Update Release is installed, the command output is V Additional information NIM installation information NOTE: This Service Pack can be combined with Update Release VIOS_ into the same lpp_source. It is recommended that you run lppmgr, to remove duplicate or redundant packages. Using NIM to back up and install the VIOS is supported as follows. - Always create the SPOT resource directly from the VIOS mksysb image. Do NOT update the SPOT from an LPP_SOURCE. - Only the updateios command should be used to update the VIOS. For further assistance, refer to the NIM documentation. To use NIM, ensure that the NIM Master is at the appropriate level to support the VIOS image. Refer to the above table in the "Package information" section. Fixes included in this release The accumulative list of fixes since APAR Description IV02817 VIOS CRASH WHEN DISABLING SEA ACCOUNTING IV02959
3 system crash at.compare_and_swaplp IV04919 CAA panic: ahafs out of buffer IV10273 LU CREATE FAILURE IV15843 clstartstop giving Execute Permission Denied IV18678 PR SHARED TYPE COULD DEFAULT TO THE WRONG VALUE AT CFG TIME IV22571 Double allocation of block during log replay of fileset create. IV23450 Concurrent migration validation fails with Partition ID xx was IV27233 LPM MAY FAIL DUE TO SPECIAL CHARACTERS IN UDID STRING IV27628 MKVDEV LOGS RAS ERROR WITH HYPHENATED LV BACKING DEVICE NAME IV28531 Data Storage Interrupt when running svm driver IV31595 CLCOMD CANNOT COMMUNICATE SOMETIMES IV32048 VIOSBR BACKUP FAILURE FOR ADAPTER WITH DUPLICATE LOC CODE IV32496 VIOSBR "ERROR: ERROR GETTING CUDV FOR VMLIBRARY_LV" IV33916 VIOSECURE FAILS WITH PREREQ FAIL FOR PREREQCDE OF *LS_XHOST RULE IV34507 VEA - INVALID VLAN ID PACKETS FOR VLAN ID > 255 IV35600 ENTRIES IN "TSD.DAT" AND "PRIVCMDS" DO NOT MATCH IV36064 CAA KE LOCK CONTENTION CAUSES NETWORK PERFORMANCE DEGRADATION
4 IV36138 REDUCEVG HANGS FOR HDISK(SCDISK) WITH DUMP DEVICE IV36390 LSPV DEBUG MESSAGES NOT LOGGED IV36977 CRASH IN TARGET_RAS_UNREGISTER IV36999 ETHCHANPROC HOGS CPU DUE TO PENDING SIGNAL IV37182 LSPV -SIZE DISK ERRORS ON READ-ONLY LUN IV37285 "LSLV -FREE" GIVES RC=1 IF ANY VG IS VARIED OFF. IV37831 Possible I/O error after a path failure IV37928 VIRT OPTICAL DEVICE RESTORE FAILS IF BACKING DEVICE NOT LOADED IV40536 CAA CLCOMD ENCOUNTERS FALSE CONNECTION CONFLICT ERROR IV40544 Potential socket corruption on cluster identity messages IV40551 CLIENT_FAILURE WITH NEWLY CREATED VSCSI CLIENT ADAPTER IV40552 CLIENT HDISK WILL NOT CONFIGURE WHEN MAPPED WITH MIRRORED=TRUE IV40562 Adapters left on VIOS source after moiblity operation. IV40574 System crashed in mpio framework config code. IV40583 Migrations and fail overs fail with reservation conflict. IV40611 ABEND IN GET_ALL_STATS
5 IV40618 UPDATEIOS MISSING QUOTE WHEN CREATING SHELL COMMAND. IV40619 MBUF LEAK WHEN CAA CLUSTER IS CONFIGURED ON TOP OF A VLANDD IV40627 CLNTOS WRONG IN "LSMAP -NPIV" WHEN CLNTNAME OVER 14 CHARS IV40628 LSMAP WITH -FMT DIDN'T DISPLAY FULL NAME OF CLIENT PARTITION IV40633 CAA must not allow disks using old scdisk device driver IV40635 Crash when using ahafs IV40643 Unable to configure VSN when SEAs' lldpsvc attribute is mixed IV40646 Tx packet drops seen on virtual adapter in VIOS. IV40903 Crash in disk driver when I/O hang is detected. IV40904 TEMP Overlapped Command errors encountered on XIV storage. IV40958 USAGE OF "AGGREGATION" FLAG IN LACPDU (8023AD ETHERCHANNEL) IV41270 MKBDSP WITH DUPLICATE LU_NAME HAS INCORRECT RETURN CODE IV41271 LSMAP MSG "DETERMINING DEVICE TYPE FAILED." WITH VLOG AS BD IV41275 clcomd consumers intermittently fail with slow host resolution IV41585 Possible crash in kexitx after close disk IV41604 LSPV -SIZE DOES NOT WORK FOR SCSI RAID DISKS
6 IV41918 Display ndd_2_flags in entstat output. IV42122 CRASH IN SCSIDISK_BUILD_ERROR DUE TO UNINITIALIZED CMD STRUCT IV42130 Crash in sfwdprocesssciolevent on recursive lock IV42217 Small possibility of a segfault in cfgscsidisk. IV43138 Cannot get Paging Space from HMC IV43869 lstcpip should not call entstat of interface is not configured Known Capabilities and Limitations The following requirements and limitations apply to Shared Storage Pool (SSP) features and any associated virtual storage enhancements. Requirements for Shared Storage Pool - Platforms: Power6 and Power7 only (includes Blades), IBM PureFlex Systems (Power Compute Nodes only) - System requirements per SSP node: - Minimum CPU: 1 CPU of guaranteed entitlement - Minimum memory: 4GB - Storage requirements per SSP cluster (minimum): 1 fiber-channel attached disk for repository, 1 GB - At least 1 fiber-channel attached disk for data, 10GB - All storage devices (repository and pool) should be allocated on Hardware RAIDed storage for redundancy. Limitations for Shared Storage Pool
7 Software Installation - Platforms: Power6 and Power7 only (includes Blades), IBM PureFlex Systems (Power Compute Nodes only) - System requirements per SSP node: - Minimum CPU: 1 CPU of guaranteed entitlement - Minimum memory: 4GB - Storage requirements per SSP cluster (minimum): 1 fiber-channel attached disk for repository, 10 GB - At least 1 fiber-channel attached disk for data, 10GB SSP Configuration Feature Min Max Number of VIOS Nodes in Cluster 1 4 Number of Physical Disks in Pool Number of Virtual Disks (LUs) Mappings in Pool Number of Client LPARs per VIOS node 1 40 Capacity of Physical Disks in Pool 10GB 4TB Storage Capacity of Storage Pool 10GB 1282TB Capacity of a Virtual Disk (LU) in Pool 1GB 4TB Number of Repository Disks 1
8 1 Maximum number of physical volumes that can be added to or replaced from a pool at one time: 64 Network Configuration - Uninterrupted network connectivity is required for operation. i.e. The network interface used for Shared Storage Pool configuration must be on a highly reliable network which is not congested. - SChanging the hostname/ip address for a system is not supported when configured in a Shared Storage Pool. - IPV4 Compliance only - When a VIOS is configured for a Shared Storage Pool environment, VLAN tagging is not supported. - A Shared Storage Pool configuration should configure the TCP/IP resolver routine for name resolution to resolve host names locally first, and then use the DNS. For step by step instructions, refer to the TCP/IP name resolution documentation in the AIX Information Center. - The forward and reverse lookup should resolve to the IP address/hostname that is used for Shared Storage Pool configuration. - When restoring VIOS LPAR configuration(s) from a viosbr backup, all network devices and configuration(s) must be restored before Shared Storage Pool configurations are restored. - The system must be configured with the fully qualified domain name. As an example the hostname command should report the system hostname as mydivision.mycompany.com. - The hostname/ip address provided for Shared Storage Pool configuration must resolve to the fully qualified domain name. - The forward and reverse lookup should resolve to the IP address/hostname that is used for Shared Storage Pool configuration. - It is recommended that the VIOSs that are part of the Shared Storage Pool configuration keep their clocks synchronized. Storage Configuration - Uninterrupted access to the repository disk is required for operation. - Physical Disks in the SAN Storage subsystem assigned to the Shared Storage Pool cannot be resized. - Virtual SCSI devices provisioned from the Shared Storage Pool may drive higher CPU utilization than the classic Virtual SCSI devices. - Using SCSI reservations (SCSI Reserve/Release and SCSI-3 Reserve) for fencing physical disks in the Shared Storage pool is not supported. - High availability SAN solutions should be utilized to mitigate outages. - SANCOM will not be supported in a Shared Storage Pool environment.
9 Shared Storage Pool and other VIOS capabilities and limitations - Virtual SCSI disk is the peripheral device type supported by SSP at this time. - VIOSs configured for SSP require that Shared Ethernet Adapter(s) (SEA) be setup for Threaded mode (the default mode). SEA in Interrupt Mode is not supported within SSP. - VIOSs configured for SSP can be used as a Paging Space Partition (PSP), but the storage for the PSP paging spaces must come from logical devices not within a Shared Storage Pool. Using a VIOS SSP logical unit (LU) as an Active Memory Sharing (AMS) paging space or as the suspend/resume file is not supported. Also, Suspend/Resume and Remote restart features for client LPARs backed by VIOS SSP LUs is not supported. - When creating Virtual SCSI Adapters for VIOS LPARs, the option "Any client partition can connect" is not supported. - Suspend/Resume and Remote Restart features for client LPARs backed by VIOS SSP LUs is not supported. Installation information Pre-installation information and instructions Please ensure that your rootvg contains at least 30GB and that there is at least 4 GB freespace before you attempt to upgrade to VIOS service release Example: Run the lsvg rootvg command, and then ensure there is enough free space. If you are planning to update a version of VIOS lower than 2.1, you must first migrate your VIOS to VIOS version using the Migration DVD. After the VIOS is at version 2.1.0, the Fix Pack Release can be applied. Then Service Release can be applied to bring the VIOS to level After the VIOS migration is complete, from 1.X to 2.X, you must set the Processor Folding attribute, described here under Migration DVD: Virtual I/O Server support for Power Systems While the above process is the most straightforward for users, you should note that with this Service Release version , a single boot alternative to this multi step process is available to NIM users. NIM users can create a single, merged lpp_source by combining the contents of the Migration DVD with the contents of Fix Pack 25 ( ). Then
10 combine the contents of this Service Release to update A single, merged lpp_source is not supported for VIOS that use SDDPCM. However, if you use SDDPCM, you can still enable a single boot update by using the alternate method described at the following location: SDD and SDDPCM migration procedures when migrating VIOS from version 1.x to version 2.x Before installing the Service Release The update could fail if there is a loaded media repository. Checking for a loaded media repository To check for a loaded media repository, and then unload it, follow these steps. - To check for loaded images, run the following command: $ lsvopt The Media column lists any loaded media. - To unload media images, run the following commands on all Virtual Target Devices that have loaded images. $ unloadopt vtd <file-backed_virtual_optical_device > - To verify that all media are unloaded, run the following command again. $ lsvopt The command output should show No Media for all VTDs.
11 Migrate Shared Storage Pool Configuration If your current VIOS is configured with Shared Storage Pools, you must follow these steps: The cluster that is created and configured between VIOS Version and can be migrated to the latest version i.e. VIOS Version This allows you to keep the shared storage pool devices. If this procedure is not followed and the cluster is running, the update will likely fail. If your current VIOS is configured with Shared Storage Pool from or later, the following information applies: Note: If you choose to destroy the devices supported by the storage pool, you can delete the cluster and skip these steps; however you will not be able to recover client data, except from existing backups, taken from client partitions. Please follow these steps. - Close all devices that are mapped to the shared storage pool. This may entail shutting down clients. Complete this step on each node in the cluster. - On a VIOS between Version and , create a backup of the old version cluster as User padmin. $ viosbr backup file oldcluster clustername clustera - Save the generated backup file oldcluster.clustera.tar.gz on a different system. - Stop cluster services on the node, this has to be done as root. Complete this step on each node in the cluster. For Version and prior, you will need to run the clstartstop command as root. $ oem_setup_env # /usr/lib/cluster/clstartstop stop n clustera m nodea # exit - Update VIOS system with Version Refer to the update sections below. Complete this step on each node in the cluster. Note: The physical volumes used for the storage pool, should remain the same and their contents should not to be altered.
12 $ updateios dev [Service Pack images location] install accept - After the installation of VIOS Version , convert the earlier backup file, created in step 3 to the new format. This generates a migrated backup file, in gz format: Note: If you came from VIOS Version or or , then you may skip this step. Example: oldcluster_migrated.clustera.tar.gz $ viosbr migrate file oldcluster.clustera.tar.gz - Start cluster services on same node as step (6). $ clstartstop start n clustera m nodea - Restore the database using migrated backup file from step (6). Note: If you came from VIOS Version or or , then you may skip this step. $ viosbr recoverdb file oldcluster_migrated.clustera.tar.gz clustername clustera After successful restore, cluster and all Shared Storage Pool mappings are configured as earlier. - Start cluster services on the remaining nodes in the cluster. $ clstartstop start n clustera m nodeb - Verify if the above cluster restored successfully. List the nodes in the cluster $ cluster status clustername clustera - List the storage mappings on the VIOS $ lsmap all
13 Installing the Update Release There is now a method to verify the VIOS update files before installation. This process requires access to openssl by the 'padmin' User, which can be accomplished by creating a link. To verify the VIOS update files, follow these steps: $ oem_setup_env Create a link to openssl # ln s /usr/bin/openssl /usr/ios/utils/openssl Verify the link to openssl was created # ls al /usr/ios/utils # exit Use one of the following methods to install the latest VIOS Service Release. As with all maintenance, you should create a VIOS backup before making changes. If you are running a Shared Storage Pool configuration, you must follow the steps in Migrate Shared Storage Pool Configuration. Note : While running 'updateios' in the following steps, you may see accessauth messages, but these messages can safely be ignored. Applying updates from a local hard disk To apply the updates from a directory on your local hard disk, follow these steps. The current level of the VIOS must be between and
14 - Log in to the VIOS as the user padmin. - If you use one or more File Backed Optical Media Repositories, you need to unload media images before you apply the Update Release. See details here.. - If you use Shared Storage Pools, then you must follow specific steps, as outlined under Migrate Shared Storage Pool. - Create a directory on the Virtual I/O Server. $ mkdir <directory_name> - Using ftp, transfer the update file(s) to the directory you created. - Commit previous updates by running the updateios command $ updateios commit - Verify the updates files that were copied. This step can only be performed if the link to openssl was created. $ cp <directory_path>/ck_sum.bff /home/padmin $ chmod 755 <directory_path>/ck_sum.bff $ ck_sum.bff <directory_path> If there are missing updates or incomplete downloads, an error message is displayed. - Apply the update by running the updateios command $ updateios accept install dev <directory_name> - To load all changes, reboot the VIOS as user padmin. $ shutdown restart - Verify that the update was successful by checking the results of the updateios command and by running the isolevel command, which should indicate that the ioslevel is now $ ioslevel
15 - If you need to restore your cluster s database, follow the steps in Migrate Shared Storage Pool Configuration. Applying updates from a remotely mounted file system If the remote file system is to be mounted read-only, follow one of these steps. The current level of the VIOS must be between and Log in to the VIOS as the user padmin. - If you use one or more File Backed Optical Media Repositories, you need to unload media images before you apply the Update Release. See details here.. - If you use Shared Storage Pools, then you must follow specific steps, as outlined under Migrate Shared Storage Pool. - Mount the remote directory onto the Virtual I/O Server. $ mount remote_machine_name:directory /mnt - Commit previous updates, by running the updateios command $ updateios commit - Verify the updates files that were copied, this step can only be performed if the link to openssl was created $ cp /mnt/ck_sum.bff /home/padmin $ chmod 755 /home/padmin/ck_sum.bff $ ck_sum.bff /mnt If there are missing updates or incomplete downloads, an error message is displayed. - Apply the update by running the updateios command $ updateios accept install dev /mnt - To load all changes, reboot the VIOS as user padmin.
16 $ shutdown restart - Verify that the update was successful by checking the results of the updateios command and by running the isolevel command, which should indicate that the ioslevel is now $ ioslevel - If you need to restore your cluster s database, follow the steps in Migrate Shared Storage Pool Configuration Performing the necessary tasks after installation Checking for an incomplete installation caused by a loaded media repository After installing an Update Release, you can use this method to determine if you have encountered the problem of a loaded media library. Check the Media Repository by running this command: $ lsrep If the command reports: "Unable to retrieve repository date due to incomplete repository structure," then you have likely encountered this problem during the installation. The media images have not been lost and are still present in the file system of the virtual media library. Running the lsvopt command should show the media images. Recovering from an incomplete installation caused by a loaded media repository To recover from this type of installation failure, unload any media repository images, and then reinstall the ios.cli.rte package. Follow these steps:
17 - Unload any media images $ unloadopt vtd <file-backed_virtual_optical_device > - If you have not yet restarted the VIOS, restart it now. You must restart before you can run the installp command in the next step. $ shutdown restart - Reinstall the ios.cli.rte fileset by running the following commands. To escape the restricted shell: $ oem_setup_env To install the failed fileset: # installp Or agx ios.cli.rte To return to the restricted shell: # exit - Verify that the Media Repository is operational by running this command: $ lsrep
Virtualization Technical Support for AIX and Linux - v2
IBM 000-109 Virtualization Technical Support for AIX and Linux - v2 Version: 5.0 Topic 1, Volume A QUESTION NO: 1 An administrator is attempting to configure a new deployment of 56 POWER7 Blades across
More informationC exam. Number: C Passing Score: 800 Time Limit: 120 min IBM C IBM AIX Administration V1.
C9010-022.exam Number: C9010-022 Passing Score: 800 Time Limit: 120 min IBM C9010-022 IBM AIX Administration V1 Exam A QUESTION 1 A customer has a virtualized system using Virtual I/O Server with multiple
More information41CO Operation and Maintaining PowerVM VIOS with IBM i
41CO Operation and Maintaining PowerVM VIOS with IBM i Gary Konicek konicek@us.ibm.com IBM Lab Services Session ID: Agenda Key: 170299 41CO Fix Strategy before June 2015 Base releases: i.e. 2.2.1.0 i.e.
More informationC IBM. Virtualization Technical Support for AIX and Linux V2
C4040-109 Dumps C4040-109 Braindumps C4040-109 Real Questions C4040-109 Practice Test C4040-109 dumps free IBM C4040-109 Virtualization Technical Support for AIX and Linux V2 http://killexams.com/pass4sure/exam-detail/c4040-109
More informationLive Partition Mobility Update
Power Systems ATS Live Partition Mobility Update Ron Barker Power Advanced Technical Sales Support Dallas, TX Agenda Why you should be planning for partition mobility What are your options? Which is best
More informationVendor: IBM. Exam Code: C Exam Name: Enterprise Technical Support for AIX and Linux -v2. Version: Demo
Vendor: IBM Exam Code: C4040-108 Exam Name: Enterprise Technical Support for AIX and Linux -v2 Version: Demo QUESTION 1 Which power reduction technology requires a software component in order to be activated?
More informationSystem i and System p. Managing the Integrated Virtualization Manager
System i and System p Managing the Integrated Virtualization Manager System i and System p Managing the Integrated Virtualization Manager Note Before using this information and the product it supports,
More informationviosupgrade command from VIOS Non-NIM environment Chris Gibson, IBM Systems Lab Services (Sept 6 th, 2018). Rough Draft.
viosupgrade command from VIOS Non-NIM environment Chris Gibson, IBM Systems Lab Services (Sept 6 th, 2018). Rough Draft. NOTE: The following document describes testing of ESP VIOS 3.1 code, pre-ga. In
More informationPASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year
PASS4TEST \ http://www.pass4test.com We offer free update service for one year Exam : C9010-022 Title : IBM AIX Administration V1 Vendor : IBM Version : DEMO Get Latest & Valid C9010-022 Exam's Question
More informationSetting up virtualization: the basics
3 Chapter 3. Setting up virtualization: the basics This chapter introduces the basics of configuring a virtual environment on an IBM System p server. The Virtual I/O Server installation and configuration
More informationIBM Systems Director VMControl
IBM Systems Director VMControl Glen Corneau Copyright IBM Corporation 2011 Materials may not be reproduced in whole or in part without the prior written permission of IBM. 5.3 Agenda > VMControl V2.3.1
More informationIntegrated Virtualization Manager. ESCALA Power7 REFERENCE 86 A1 41FF 08
Integrated Virtualization Manager ESCALA Power7 REFERENCE 86 A1 41FF 08 ESCALA Models Reference The ESCALA Power7 publications concern the following models: Bull Escala E1-700 / E3-700 Bull Escala E1-705
More informationMechanic v. Surgeon (photos from istockphoto.com)
0 Mechanic v. Surgeon (photos from istockphoto.com) 1 2007: AIX Kernel hotpatch support available with AIX 6.1 2008: Ksplice Linux hotpatch support (based on MIT student s master s thesis) Stops all running
More informationKillTest *KIJGT 3WCNKV[ $GVVGT 5GTXKEG Q&A NZZV ]]] QORRZKYZ IUS =K ULLKX LXKK [VJGZK YKX\OIK LUX UTK _KGX
KillTest Q&A Exam : 000-108 Title : Enterprise Technical Support for AIX and Linux -v2 Version : Demo 1 / 7 1.Which power reduction technology requires a software component in order to be activated? A.
More informationIBM Virtualization Technical Support for AIX and Linux - v2.
IBM 000-109 Virtualization Technical Support for AIX and Linux - v2 http://killexams.com/exam-detail/000-109 QUESTION: 170 A Power Systems server has two HMCs connected to its Flexible Service Processor
More informationIBM EXAM QUESTIONS & ANSWERS
IBM 000-106 EXAM QUESTIONS & ANSWERS Number: 000-106 Passing Score: 800 Time Limit: 120 min File Version: 38.8 http://www.gratisexam.com/ IBM 000-106 EXAM QUESTIONS & ANSWERS Exam Name: Power Systems with
More information3.5.5 Creating client partitions
Example 3-27 Logical partitions are mapped to two physical partitions $ lsvg -lv rootvg rootvg: LV NAME TYPE LPs PPs PVs LV STATE MOUNT POINT hd5 boot 1 2 2 closed/syncd N/A hd6 paging 4 8 2 open/syncd
More informationLive Partition Mobility
Live Partition Mobility Jaqui Lynch lynchj@forsythe.com Presentation at: http://www.circle4.com/forsythe/lpm2014.pdf 1 1 Why Live Partition Mobility? LPM LIVE PARTITION MOBILITY Uses Server Consolidation
More informationIBM Exam A Virtualization Technical Support for AIX and Linux Version: 6.0 [ Total Questions: 93 ]
s@lm@n IBM Exam A4040-101 Virtualization Technical Support for AIX and Linux Version: 6.0 [ Total Questions: 93 ] IBM A4040-101 : Practice Test Question No : 1 Which of the following IOS commands displays
More informationAdvanced Virtual I/O Server Configurations. César Diniz Maciel Consulting IT Specialist IBM US
Advanced Virtual I/O Server Configurations César Diniz Maciel Consulting IT Specialist IBM US Agenda Virtual Optical Devices, Virtual Optical Media, File-backed Devices Shared Ethernet Adapter (SEA) Failover
More informationBest Practices: Managing AIX Updates using SUMA, NIM, and AIX Service Tools Steven Molis
using SUMA, NIM, and AIX Service Tools Steven Molis AIX Development smolis@us.ibm.com Table of Contents 1 INTRODUCTION... 3 2 BEST PRACTICES USING SUMA AND NIM... 4 2.1 GETTING UPDATES FOR A SINGLE SYSTEM
More informationUsing VMware vsphere With Your System
Using VMware vsphere, page 1 Configuring the ESXi Host to Use an NTP Server, page 2 Creating a Backup by using VMware vcenter, page 2 Taking a Snapshot by using VMware vcenter, page 3 Attaching an Existing
More informationQ&As. AIX 7 Administration. Pass IBM Exam with 100% Guarantee. Free Download Real Questions & Answers PDF and VCE file from:
000-221 Q&As AIX 7 Administration Pass IBM 000-221 Exam with 100% Guarantee Free Download Real Questions & Answers PDF and VCE file from: 100% Passing Guarantee 100% Money Back Assurance Following Questions
More informationSystem p. Partitioning with the Integrated Virtualization Manager
System p Partitioning with the Integrated Virtualization Manager System p Partitioning with the Integrated Virtualization Manager Note Before using this information and the product it supports, read the
More informationPower Systems with POWER8 Scale-out Technical Sales Skills V1
Power Systems with POWER8 Scale-out Technical Sales Skills V1 1. An ISV develops Linux based applications in their heterogeneous environment consisting of both IBM Power Systems and x86 servers. They are
More informationExam Name: Virtualization Technical Support for AIX and
Exam Code: 000-101 Exam Name: Virtualization Technical Support for AIX and Linux Vendor: IBM Version: DEMO Part: A 1: A customer has a Power 570 system with the following configuration: 2 active CPUs 16
More informationPowerVM simplification enhancements. PowerVM simplification enhancements. PowerVM infrastructure overview
PowerVM simplification enhancements PowerVM infrastructure overview IBM PowerVM is the virtualization solution that enables workload consolidation for AIX, IBM i, and Linux environments on IBM Power Systems
More informationIBM SYSTEM POWER7. PowerVM. Jan Kristian Nielsen Erik Rex IBM Corporation
IBM SYSTEM POWER7 PowerVM Jan Kristian Nielsen jankn@dk.ibm.com - +45 28803310 Erik Rex Rex@dk.ibm.com - +45 28803326 PowerVM: Virtualization Without Limits Reduces IT infrastructure costs Improves service
More informationC Examcollection.Premium.Exam.52q
C4040-108.Examcollection.Premium.Exam.52q Number: C4040-108 Passing Score: 800 Time Limit: 120 min File Version: 36.9 http://www.gratisexam.com/ Exam Code: C4040-108 Exam Name: Power Systems Enterprise
More informationIBM EXAM - C AIX 7 Administration. Buy Full Product.
IBM EXAM - C4040-221 AIX 7 Administration Buy Full Product http://www.examskey.com/c4040-221.html Examskey IBM C4040-221 exam demo product is here for you to test the quality of the product. This IBM C4040-221
More informationPlanning for Virtualization on System P
Planning for Virtualization on System P Jaqui Lynch Systems Architect Mainline Information Systems Jaqui.lynch@mainline.com com http://www.circle4.com/papers/powervm-performance-may09.pdf http://mainline.com/knowledgecenter
More informationIBM - C AIX 7 Administration Version: 7.1
IBM - C4040-221 AIX 7 Administration Version: 7.1 1 Topic 1, Volume A QUESTION: 1 The following information has been reported in an AIX error log: How can the administrator prevent the error from reoccurring?
More informationUsing VMware vsphere with Your System
Using VMware vsphere, on page 1 Configuring the ESXi Host to Use an NTP Server, on page 2 Creating a Backup by Using VMware vcenter, on page 2 Taking a Snapshot by using VMware vcenter, on page 3 Removing
More informationApplication and Partition Mobility
IBM System p Application and Mobility Francis COUGARD IBM Products and Solutions Support Center Montpellier Copyright IBM Corporation 2009 Index Application and Mobility Presentation Videocharger and DB2
More informationIBM Exam C IBM AIX Administration V1 Version: 7.0 [ Total Questions: 258 ]
s@lm@n IBM Exam C9010-022 IBM AIX Administration V1 Version: 7.0 [ Total Questions: 258 ] IBM C9010-022 : Practice Test Topic break down Topic No. of Questions Topic 1: Volume A 49 Topic 2: Volume B 50
More informationIBM Solutions Advanced Technical Support
DB2 and SAP Disaster Recovery using DS8300 Global Mirror IBM Solutions Advanced Technical Support Nasima Ahmad Chris Eisenmann Jean-Luc Degrenand Mark Gordon Mark Keimig Damir Rubic Version: 1.1 Date:
More informationIBM i on a Power Blade Read-me First. Vess Natchev Power Blades Virtualization Cloud IBM Rochester, MN
IBM i on a Power Blade Read-me First Vess Natchev Power Blades Virtualization Cloud IBM Rochester, MN vess@us.ibm.com October 30 th, 2009 1 This read-me first document provides detailed instructions on
More informationPowerHA SystemMirror 6.1 to migrating Prerequisites
PowerHA SystemMirror 6.1 to 7.1.3 migrating Prerequisites Abstract: Whenever we are going to perform PowerHA SystemMirror rolling or snapshot migration from 6.1 to 7.1.3 we have to fulfill the prerequisites.
More informationVirtualization Benefits IBM Corporation
Virtualization Benefits 1 Virtualization Benefits CPU Utilization 100 90 80 70 60 50 40 30 20 10 0 8:00 10:00 12:00 2:00 4:00 Time Purchased Peak Average Increase Utilization Non-virtualized servers often
More informationBMC Capacity Optimization Extended Edition AIX Enhancements
BMC Capacity Optimization Extended Edition 9.5.1 AIX Enhancements Support for AIX Active Memory Expansion (AME) mode Metrics displayed in BCO AIX PowerVM view for CPU and Memory Allocation Frame name,
More informationThe Power of PowerVM Power Systems Virtualization. Eyal Rubinstein
The Power of PowerVM Power Systems Virtualization Eyal Rubinstein deyal@il.ibm.com The Power Equation: Power = i + p System i i515 i525 i550 i570 i595 IBM BladeCenter BladeCenter JS12/22/23 Express BladeCenter
More informationAvaya Aura TM System Platform R6.0 Release Notes Issue 2.0
Avaya Aura TM Release Notes Issue 2.0 INTRODUCTION This document introduces the Avaya Aura TM System Platform Release 6.0 and describes known issues and the issues resolved in this release. Please Note:
More informationPower Systems SAN Multipath Configuration Using NPIV v1.2
v1.2 Bejoy C Alias IBM India Software Lab Revision History Date of this revision: 27-Jan-2011 Date of next revision : TBD Revision Number Revision Date Summary of Changes Changes marked V1.0 23-Sep-2010
More informationVirtual I/O Server Beyond the Basics
Virtual I/O Server Beyond the Basics MITEC 2011 W 210 C-4 James Nash Advanced Technical Skills jjnash@us.ibm.com Trademarks The following are trademarks of the International Business Machines Corporation
More informationActual4Test. Actual4test - actual test exam dumps-pass for IT exams
Actual4Test http://www.actual4test.com Actual4test - actual test exam dumps-pass for IT exams Exam : 000-180 Title : P5 and pseries Enterprise Technical Support Aix 5L V5.3 Vendors : IBM Version : DEMO
More informationIntroduction to PowerHA SystemMirror for AIX V 7.1 Managed with IBM Systems Director
Introduction to PowerHA SystemMirror for AIX V 7.1 Managed with Director IBM s High Availability Software for POWER Based Systems Glenn Miller Certified IT Specialist Systems Software Architect gemiller@us.ibm.com
More informationPlanning and Sizing Virtualization
Planning and Sizing Virtualization Jaqui Lynch Architect, Systems Engineer Mainline Information Systems http://www.circle4.com/papers/cmgvirt.pdf 1 What is Virtualization? Being able to dynamically move
More informationIBM PureFlex Technical
IBM PureFlex Technical Number: 000-783 Passing Score: 660 Time Limit: 90 min File Version: 1.0 http://www.gratisexam.com/ Exam A QUESTION 1 Which of the following virtualization products is required to
More informationC IBM AIX Administration V1
C9010-022 - IBM AIX Administration V1 1.The system administrator ran the following command to backup his image repository, but nothing was backed up to the file. Why? find /media -print backup -I-f-p /dev/rmt0
More informationMigrating Data from Cisco Security MARS 4.x to 6.0.x
Migrating Data from Cisco Security MARS 4.x to 6.0.x Revised: March 24, 2009, Cisco Security MARS 6.0.x runs on all MARS Appliance models, specifically: 20, 20R, 50, 100, 100e, 200, GC, and GCm 1 25, 25R,
More informationVendor: IBM. Exam Code: C Exam Name: Power Systems with POWER7 and IBM i Technical Sales Skills -v2. Version: Demo
Vendor: IBM Exam Code: C4040-226 Exam Name: Power Systems with POWER7 and IBM i Technical Sales Skills -v2 Version: Demo Question No : 1 A customer with a POWERS 520 running IBM i is debating consolidating
More informationAbout This Book. Who Should Use This Book. Highlighting. Case Sensitivity in AIX. iii
About This Book The AIX 5L Version 5.2 Operating System Installation: Getting Started guide provides system administrators with information about how to install and configure the AIX operating system on
More information10 Having Hot Spare disks available in the system is strongly recommended. There are two types of Hot Spare disks:
0 This Web Based Training module provides support and maintenance related information for the ETERNUS DX S2 family. This module provides an introduction to a number of ETERNUS Web GUI functions, for a
More informationIBM Endpoint Manager Version 9.1. Patch Management for AIX User's Guide
IBM Endpoint Manager Version 9.1 Patch Management for AIX User's Guide IBM Endpoint Manager Version 9.1 Patch Management for AIX User's Guide Note Before using this information and the product it supports,
More informationIBM C IBM AIX Administration V1. Download Full Version :
IBM C9010-022 IBM AIX Administration V1 Download Full Version : http://killexams.com/pass4sure/exam-detail/c9010-022 QUESTION: 251 Consider the following screen capture. The administrator needs to add
More information1. Introduction. 2. TPM, pseries and AIX NIM Environment
1. Introduction This paper is to describe the following functions of Tivoli Provisioning Manager (TPM) with the automation packages of pseries-server and NIM that are installed with TPM and Tivoli Intelligent
More informationAIX Host Utilities 6.0 Installation and Setup Guide
IBM System Storage N series AIX Host Utilities 6.0 Installation and Setup Guide GC27-3925-01 Table of Contents 3 Contents Preface... 6 Supported features... 6 Websites... 6 Getting information, help,
More informationSymbols INDEX > 12-14
INDEX Symbols > 12-14 A AAA accounting configuring 6-32 AAA-based management systems 2-25, 6-2 acceleration about 1-6, 12-1 features 1-6 TCP settings 12-17 accounts creating 7-3 creation process 7-2 deleting
More informationVendor: IBM. Exam Code: C Exam Name: Power Systems with POWER8 Scale-out Technical Sales Skills V1. Version: Demo
Vendor: IBM Exam Code: C9010-251 Exam Name: Power Systems with POWER8 Scale-out Technical Sales Skills V1 Version: Demo QUESTION 1 What is a characteristic of virtualizing workloads? A. Processors are
More informationIBM PowerHA SystemMirror for AIX. Standard Edition. Version 7.1. PowerHA SystemMirror concepts IBM
IBM PowerHA SystemMirror for AIX Standard Edition Version 7.1 PowerHA SystemMirror concepts IBM IBM PowerHA SystemMirror for AIX Standard Edition Version 7.1 PowerHA SystemMirror concepts IBM Note Before
More informationAVAYA Avaya Aura System Platform Service Pack R6.2.1 Release Notes Issue 1.3
AVAYA R6.2.1 Release Notes Issue 1.3 INTRODUCTION This document introduces the Release 6.2.1 and describes known issues and the issues resolved in this release. SOFTWARE RELEASE VERSIONS Release Date File
More informationC Number: C Passing Score: 800 Time Limit: 120 min File Version: 5.0. IBM C Questions & Answers
C4040-251 Number: C4040-251 Passing Score: 800 Time Limit: 120 min File Version: 5.0 http://www.gratisexam.com/ IBM C4040-251 Questions & Answers Power Systems with POWER8 Scale-out Technical Sales Skills
More informationExperiences with VIOS support for IBM i
Experiences with VIOS support for IBM i Pete Stephen, Power Systems / AIX Architect Sirius Computer Solutions Pete.Stephen@siriuscom.com Agenda VIO overview Virtualization Trends. PowerVM and how do I
More informationExam Name: Enterprise Technical Support for AIX and
Exam Code: 000-100 Exam Name: Enterprise Technical Support for AIX and Linux Vendor: IBM Version: DEMO Part: A 1: After configuring a Shared Ethernet Adapter (SEA) on a Virtual I/O server, one client partition
More informationPower Systems with POWER7 and AIX Technical Sales
Power Systems with POWER7 and AIX Technical Sales Number: 000-107 Passing Score: 800 Time Limit: 120 min File Version: 26.6 http://www.gratisexam.com/ IBM 000-107 EXAM QUESTIONS & ANSWERS Exam Name: Power
More informationStorage Profiles. Storage Profiles. Storage Profiles, page 12
, page 1 Disk Groups and Disk Group Configuration Policies, page 2 RAID Levels, page 6 Automatic Disk Selection, page 7 Supported LUN Modifications, page 8 Unsupported LUN Modifications, page 8 Disk Insertion
More informationInstalling the IBM ServeRAID Cluster Solution
Installing the IBM ServeRAID Cluster Solution For IBM Netfinity ServeRAID-4x Ultra160 SCSI Controllers Copyright IBM Corp. 2000 1 2 IBM Netfinity Installing the IBM ServeRAID Cluster Solution Chapter 1.
More informationONTAP 9 Cluster Administration. Course outline. Authorised Vendor e-learning. Guaranteed To Run. DR Digital Learning. Module 1: ONTAP Overview
ONTAP 9 Cluster Administration Course Code: Duration: 3 Days Product Page: https://digitalrevolver.com/product/ontap-9-cluster-administration-2/ This 3-day, instructor led course uses lecture and hands-on
More informationPower Systems. IBM Power 595 (9119-FHA) removal and replacement procedures
Power Systems IBM Power 595 (9119-FHA) removal and replacement procedures Power Systems IBM Power 595 (9119-FHA) removal and replacement procedures Note Before using this information and the product it
More informationTestinexam Number: Passing Score: 800 Time Limit: 120 min File Version: 1.0
Testinexam 000-272 Number: 000-272 Passing Score: 800 Time Limit: 120 min File Version: 1.0 http://www.gratisexam.com/ www.test-inexam.com Exam A QUESTION 1 Which power reduction technology requires a
More informationUnit 2 System startup and shutdown
Unit 2 System startup and shutdown Course materials may not be reproduced in whole or in part without the prior written permission of IBM. 5.2 Unit objectives After completing this unit, you should be
More informationUsing VMware vsphere With Your System
Using VMware vsphere, page 1 Configuring the ESXi Host to Use an NTP Server, page 2 Creating a Backup Using VMware vcenter, page 2 Taking a Snapshot Using VMware vcenter, page 3 Attaching an Existing VMDK
More informationPlasmon Diamond Library Manager
Plasmon Diamond Library Manager Release Details Product Release Notes Release Name: Diamond Library Manager Release Note Number: Note091 Release Version: 2.09.31 Release Date: 1 st July 2005 Release Type:
More informationIBM Exam AIX 7 Administration Version: 9.1 [ Total Questions: 229 ]
s@lm@n IBM Exam 000-221 AIX 7 Administration Version: 9.1 [ Total Questions: 229 ] Topic 2, Volume B Question No : 1 - (Topic 2) An administrator migrated a global environment of AIX 6 to AIX 7 using NIM.
More informationA review of AIX Container Technology: with perspectives on. Docker Management Operations. Zeyuan Zhu. AIX Development Engineer
A review of AIX Container Technology: with perspectives on Docker Management Operations Zeyuan Zhu AIX Development Engineer In this paper, I'm going to give you an introduction to container technology,
More informationIBM p5 and pseries Enterprise Technical Support AIX 5L V5.3. Download Full Version :
IBM 000-180 p5 and pseries Enterprise Technical Support AIX 5L V5.3 Download Full Version : https://killexams.com/pass4sure/exam-detail/000-180 A. The LPAR Configuration backup is corrupt B. The LPAR Configuration
More informationThis page is intentionally left blank.
This page is intentionally left blank. Preface This ETERNUS Multipath Driver User's Guide describes the features, functions, and operation of the "ETERNUS Multipath Driver" (hereafter referred to as "Multipath
More informationIBM Exam C IBM Storwize V7000 Implementation V1 Version: 6.0 [ Total Questions: 78 ]
s@lm@n IBM Exam C4090-457 IBM Storwize V7000 Implementation V1 Version: 6.0 [ Total Questions: 78 ] Question No : 1 How many days can an external virtualization license be used for migration before incurring
More informationIBM Tivoli Storage Manager for HP-UX Version Installation Guide IBM
IBM Tivoli Storage Manager for HP-UX Version 7.1.4 Installation Guide IBM IBM Tivoli Storage Manager for HP-UX Version 7.1.4 Installation Guide IBM Note: Before you use this information and the product
More informationPASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year
PASS4TEST IT Certification Guaranteed, The Easy Way! \ http://www.pass4test.com We offer free update service for one year Exam : A4040-221 Title : Assessment: AIX 7 Administration Vendors : IBM Version
More informationVIOS Shared Storage Pool 6 Reminder of the Basics & Advanced Topics & Demo
AIX Virtual User Group VIOS Shared Storage Pool 6 Reminder of the Basics & Advanced Topics & Demo Nigel Griffiths Power Systems Advanced Technology Support IBM Europe 2016 IBM Corporation Agenda 2 Info:
More informationAvaya Aura TM System Platform R6.0.1 Service Pack Release Notes Issue 1.4
Avaya Aura TM Service Pack Release Notes Issue 1.4 INTRODUCTION This document introduces the Avaya Aura TM System Platform Release 6.0.1 Service Pack and describes known issues and the issues resolved
More informationvsphere Installation and Setup Update 2 Modified on 10 JULY 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5
vsphere Installation and Setup Update 2 Modified on 10 JULY 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 You can find the most up-to-date technical documentation on the VMware website at:
More informationThe Contents and Structure of this Manual. This document is composed of the following 12 chapters.
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationConfiguring Storage Profiles
This part contains the following chapters: Storage Profiles, page 1 Disk Groups and Disk Group Configuration Policies, page 2 RAID Levels, page 3 Automatic Disk Selection, page 4 Supported LUN Modifications,
More informationLive Partition Mobility ESCALA REFERENCE 86 A1 85FA 01
Lie Partition Mobility ESCALA REFERENCE 86 A1 85FA 01 ESCALA Lie Partition Mobility Hardware May 2009 BULL CEDOC 357 AVENUE PATTON B.P.20845 49008 ANGERS CEDE 01 FRANCE REFERENCE 86 A1 85FA 01 The following
More informationA+ Guide to Hardware, 4e. Chapter 7 Hard Drives
A+ Guide to Hardware, 4e Chapter 7 Hard Drives Objectives Learn how the organization of data on floppy drives and hard drives is similar Learn about hard drive technologies Learn how a computer communicates
More informationUsing VMware vsphere With Your System
Using VMware vsphere, page 1 Configuring the ESXi Host to Use an NTP Server, page 2 Creating a Backup Using VMware vcenter, page 2 Taking a Snapshot Using VMware vcenter, page 3 Attaching an Existing VMDK
More information3.1. Storage. Direct Attached Storage (DAS)
3.1. Storage Data storage and access is a primary function of a network and selection of the right storage strategy is critical. The following table describes the options for server and network storage.
More informationNumber: Passing Score: 800 Time Limit: 120 min File Version: 1.0. Vendor: IBM. Exam Code:
000-332 Number: 000-000 Passing Score: 800 Time Limit: 120 min File Version: 1.0 http://www.gratisexam.com/ Vendor: IBM Exam Code: 000-332 Exam Name: High Availability for AIX - Technical Support and Administration
More informationGrover Davidson Senior Software Engineer, AIX Development Support IBM pin541 Hidden Features and Functionality in AIX
Grover Davidson grover@us.ibm.com Senior Software Engineer, AIX Development Support IBM pin541 Hidden Features and Functionality in AIX Copyright IBM Corporation 2014 Technical University/Symposia materials
More informationIBM EXAM QUESTIONS & ANSWERS
IBM 000-108 EXAM QUESTIONS & ANSWERS Number: 000-108 Passing Score: 800 Time Limit: 120 min File Version: 46.6 http://www.gratisexam.com/ IBM 000-108 EXAM QUESTIONS & ANSWERS Exam Name: Enterprise Technical
More informationGuest Operating System Installation Guide. February 25, 2008
Guest Operating System Installation Guide February 25, 2008 Guest Operating System Installation Guide Guest Operating System Installation Guide Revision: 20080225 Item: GSTOS-ENG-Q108-198 You can find
More informationIBM p5 Virtualization Technical Support AIX 5L V5.3. Download Full Version :
IBM 000-062 p5 Virtualization Technical Support AIX 5L V5.3 Download Full Version : https://killexams.com/pass4sure/exam-detail/000-062 A. Virtual Ethernet B. Micro-Partitioning C. Virtual I/O Server D.
More informationHP Supporting the HP ProLiant Storage Server Product Family.
HP HP0-698 Supporting the HP ProLiant Storage Server Product Family https://killexams.com/pass4sure/exam-detail/hp0-698 QUESTION: 1 What does Volume Shadow Copy provide?. A. backup to disks B. LUN duplication
More informationAIX 7.2 Live Update. 26/11/2015 Chris Gibson AIX/Power CTS
26/11/2015 Chris Gibson AIX/Power CTS cgibson@au1.ibm.com November 2015 ASEAN Technical Update Chris Gibson (cgibson@au1.ibm.com) AIX & Power Systems Technical Consultant at IBM STG. IBM Champion for Power
More informationGuest Operating System Installation Guide. March 14, 2008
Guest Operating System Installation Guide March 14, 2008 Guest Operating System Installation Guide Guest Operating System Installation Guide Revision: 20080314 Item: GSTOS-ENG-Q108-198 You can find the
More informationConfiguring Storage Profiles
This part contains the following chapters: Storage Profiles, page 1 Disk Groups and Disk Group Configuration Policies, page 2 RAID Levels, page 3 Automatic Disk Selection, page 4 Supported LUN Modifications,
More informationScrutinizer Virtual Appliance Deployment Guide Page i. Scrutinizer Virtual Appliance Deployment Guide. plixer
Scrutinizer Virtual Appliance Deployment Guide Page i Scrutinizer Virtual Appliance Deployment Guide Contents What you need to know about deploying a Scrutinizer virtual appliance.. 1 System Requirements..................................2
More information"Charting the Course... Enterprise Linux System Administration Course Summary
Course Summary Description This is an in-depth course that explores installation, configuration and maintenance of Linux systems. The course focuses on issues universal to every workstation and server.
More information