12.2 PROGRAMMING SECTION

Size: px
Start display at page:

Download "12.2 PROGRAMMING SECTION"

Transcription

1 . PGAMMING SECTIN PC-

2 All programming of the V is done in the service mode as indicated in the following steps below. The main service modes are indicated in white text and the sub-modes are indicated in black text. Example: Time/Date Setting Mode Year Setting Month Setting Date Setting Hour Setting Daylight Saving Time PC-

3 FU-BUTTN PGAMMING All programming of the V- options is done in the service mode. To enter the service mode, open the vendor door and press and release the service mode button that is located on the control board. The first four selection buttons are used to navigate through the programming as follows: Button Description Usage Selection Button Abort Escape, Cancel Selection Button Up Increase, Next Selection Button Down Decrease, Previous Selection Button Enter K, Accept, Save The controller will automatically return to the open door sales mode if:. No information from the selection switches is received within approximately five minutes.. The service mode button is pressed a second time.. The (Abort) button is pressed.. The rtn function is activated. If the door is closed, the controller will exit the service mode and return to the sales mode. When the programming is entered, any established credit is returned to the customer. PC-

4 SET-UP AND CDE DESCIPTIN Error Display Mode If (Enter) is pressed at the prompt, the controller will enter the error display mode. If no errors have occurred, the display will show. If an error has been detected since the last error reset, the display will show the first error summary code that has occurred. EXAMPLE: would indicate (a column jam error). If (Enter) is pressed, the controller will display the detailed error for the summary code. Pressing (Up and Down) will cycle through any remaining error detail codes. If (Abort) is pressed while displaying any detailed code, the controller will return to the summary code. If (Abort) is pressed while displaying any summary code, the controller will return to the prompt. Note: See Error Code Map on next page Clearing an Error If (Enter) is pressed and held for two seconds during the display of the detailed error code, that error will be cleared. If other currently accessed detailed errors exist, the next error will now be displayed. If no other errors of this type exist, the next error summary code will now be displayed, or if no other errors exist. Coin Pay-out Mode If (Enter) is pressed at the prompt, the controller will enter the coin pay-out mode and display the lowest coin value that can be paid out (.5,.0,.5 etc.). The (Up or Down) selection buttons will allow the operator to cycle through the coin tube selections. If (Enter) is pressed, a pay out of the displayed value will be made. Coins will continue to pay out as long as (Enter) is held down. If (Abort) is pressed at any time, the controller will return to the prompt. EXAMPLE: If (Enter) is pressed while.05 is displayed, a nickel will be dispensed. Tube Fill Mode If (Enter) is pressed at the prompt, the controller will enter the coin tube fill mode. In this mode, the operator is allowed to deposit any coin into the coin changer s acceptor when that coin s tube is not full. The tube inventory level will be displayed after each coin is accepted. If (Abort) is pressed at any time during this operation, the controller will return to the prompt. PC-

5 Error Codes none UEnd CtrL SEL StS CHAr bual Crdr Ln rund S-d rfrg Summary level error codes (as displayed) Detail level error codes (as displayed) CJXX Column jam in column XX Complete a test vend cycle for column CS Chute sensor error Check or replace chute sensor assembly ds ran ACL SF IS Ib SLXX UAXX CC ts IC tjxx CrCH EE nj LA dis rout Description No errors exist Vend mechanism summary error Control system summary error ESC Escrow motor error Check or replace escrow motor assembly Door Switch AM check sum of service mode settings AC supply low Scale factor incompatibility Machine inlet chute sensor is blocked Machine inlet chute is blocked Selection switch summary error Selection switch error in switch XX Space-to-sales summary error Unassigned column for column XX Changer summary error No changer communication Tube sensor error Changer inlet chute blocked Tube payout jam in tube XX Changer M check sum error Excessive escrow attempts Coin jam Acceptance rate below 80% Disconnected acceptor Coin routing error Error codes are cleared by pressing the ENTE button for sec. when displayed or automatically by the following activities: CS Chute sensor error Check or replace chute sensor assembly Door Closed Change any service mode setting Scale factor corrected Blockage removed Switch opens Column is assigned Proper communication Changer corrected A coin is sensed Changer corrected Changer corrected A valid coin is sensed A coin is sensed Acceptance rate improves above 80% Acceptor properly connected Coin is routed properly Bill validator summary error bc No bill validator communication Proper communication bful Bill validator stacker full eceive stacker command bill Defective bill validator motor Validator becomes enabled bj Bill validator jam Validator becomes enabled brch Bill validator M check sum error Validator becomes enabled bpn Bill validator stacker is open or out of position Validator becomes enabled bs Bill validator sensor error Validator becomes enabled CrC CrXY C nc I ruc ru X SdC SdX Card reader summary error No card reader communication Card reader non-transient error: code X, sub-code Y n-line module summary error No on-line module communication No on-line network communication n-line module internal error emote vend mechanism (USD) summary error No communication with remote vend mechanism " " Error X from remote vend mechanism " " Selection/display device (ASD) summary error No selection/display device communication Error X from selection/display device Coin detected by changer Proper communication Error stops being reported Proper communication Proper communication esolved by LM Proper communication Device specific Proper communication Device specific efrigeration system summary error SEnS CLd Hot Temperature sensor defective or unplugged Cabinet temperature F below low limit Cabinet temperature F above high limit Sensor detected Temperature rises above low limit Temperature falls below upper limit CnPr Cooling system not cooling System cools F per hour Htr Heating system not heating System heats F per hour PC-5

6 SET-UP AND CDE DESCIPTIN (CNTINUED) Test Mode If (Enter) is pressed at the prompt, the controller will enter the test mode option. Upon entry into the test mode, the display will show the first summary test,. Pressing (Up or Down) will cycle through the available tests as listed below. Pressing (Enter) will enter the detailed test mode option. Pressing (Abort) while a summary test prompt is displayed will return the controller to the prompt. Test vend motor TEST PTINS Column jog test routine Test selection switch Test sold-out switches (reserved for future option) Check display/led Check compressor, fan, lights and heater relays Test Vend Motor If (Enter) is pressed at the prompt, the mode is displayed. If (Enter) is pressed at the prompt, the controller will enter the column vend test option. Upon entry into this setting the display will show. This will indicate that a test vend of column may be done. Pressing (Up or Down) will toggle through the available columns. Pressing (Enter) will test vend the displayed column. Pressing (Abort) will return the controller to the prompt. Column Jog Test outine If (Enter) is pressed at the prompt, the controller will enter the column jog test routine. Upon entry into this routine the display will show a message indicating that a jog test of column may be initiated. Using the (Up or Down) buttons will cycle through the available columns. Pressing the (Enter) button will display a message indicating the forward direction. Using the (Up or Down) buttons will toggle between (forward) and (reverse). Pressing the (Enter) button will initiate a jog test of the last displayed column in the last displayed direction. During the jog test, the direction of travel will remain indicated on the display. The motor will be activated and remain activated until the (Enter) button is released. The motor will continue in the direction of travel without regard to vend position until it reaches the stopping point on the coupling cam. Pressing (Abort) will return the controller to the prompt. NTE: Throughout the entire jog process, the motor will not be allowed to continue to a point or in a direction that would damage any part of the mechanism. PC-6

7 SET-UP AND CDE DESCIPTIN (CNTINUED) Selection Switch Test If (Enter) is pressed at the prompt, the controller will enter the selection switch test option. Upon entry into this setting the display will show. This indicates that the fourth button was pressed last. The last selection switch pressed will remain on the display until the service mode timer expires or the (Abort) button is pressed and held for two seconds. This will return the controller to the prompt. Sold-out Switch Test eserved for Future ption If (Enter) is pressed at the prompt, the controller will enter the sold-out test option. Upon entry into this setting the display will show. This indicates that column is not sold-out. If display shows this will indicate that the displayed column is sold-out. Pressing (Up or Down) buttons will toggle through the columns. Pressing (Abort) will return the controller to the prompt. EXAMPLE: 0 = Column is not Sold-out. = Column is Sold-out. Check Display/LED If (Enter) is pressed at the prompt, the controller will enter the display test option. Upon entry into this setting the display will toggle through all the vertical and horizontal display elements within each digit. The test will continue until the service mode timer expires or the (Abort) button is pressed. This will return the controller to the prompt. Check Compressor, Light and Heater elays If (Enter) is pressed at the prompt, the controller will enter the relay test option. Upon entry into this setting the display will show the state of the first component, This means the compressor is not activated and means the compressor is activated. Pressing (Enter) will toggle the state of the compressor. Pressing (Up or Down) will toggle through the available components as listed below. Pressing (Abort) will return the controller to the prompt. NTE: All components will be returned to their initial state, 0, upon the exit of this test routine. EXAMPLE: 0 = Means relay is de-activated. = Means relay is activated. CMPNENT LIST Controls the compressor Controls the evaporator fans Controls the lights Controls the heater option (optional kit) Note: Pressing (Enter) will return you to the. PC-7 prompt. Pressing (Up) will get you into

8 SET-UP AND CDE DESCIPTIN (CNTINUED) Password Protection will display only if the password has not been entered. The password is entered via the first four selection buttons while the controller is displaying. The password must be entered within 0 seconds in the following order: ---. The display will show a dash after the first selection button is pressed. After completing the sequence, press (Enter). If the password is not recognized, the display will remain blank. Cash Counter Display Mode If (Enter) is pressed at the prompt, the controller will enter the non-resettable cash counter mode by displaying. Pressing (Enter) will display cash total over the control board s life. A decimal will be displayed in the appropriate position. Pressing (Up or Down) will change the display to, which will give the card reader historical information. Pressing (Up or Down) again will change the display to / XXXX where N is a selection number and the XXXX will be replaced with the current re-settable cash amount. Using the (Up or Down) will cycle through the available selections. If (Abort) is pressed at anytime during this operation, the controller will return to the prompt. Vend Counter Display Mode If (Enter) is pressed at the prompt, the controller will enter the non-resettable vend counter display mode by displaying. Pressing (Enter) will display the number of all paid vends over the control board s life. Using (Up or Down) will cycle through each selection as / where the indicates the selection and the 0 s represent the resettable number of vends for that selection. A decimal will be displayed in the appropriate position. If (Abort) is pressed anytime during this operation, the controller will return to the prompt. Selection Price Setting Mode If (Enter) is pressed at the prompt, the controller will enter the selection price setting mode. The display will show if the machine is in multi-price mode, or if the machine is in single-price mode. In the multi-price mode, individual selection prices can be changed using the (Up or Down) to display where XX is the selection number, or choose to change the prices for all selection. If (Enter) is pressed, the display will show the current price for the displayed selection. Using (Up or Down) will increase or decrease the price. Holding (Up or Down) for more than five seconds will cause the price to change at 0 times the normal rate. While the desired price is on the display, press (Enter) and it will save that price. Pressing (Abort) will return to the selection level without saving the new price. PC-8

9 SET-UP AND CDE DESCIPTIN (CNTINUED) Depth Setting If (Enter) is pressed at the prompt, the controller will enter the depth setting programming mode by displaying X where X is the current depth setting. Using (Up or Down) will allow the operator to cycle through the available depth setting options (-). When one of the depth settings is on the display, pressing (Enter) will select that depth setting and return to the prompt. If one of the depth settings is displayed and (Abort) is pressed, the user will return to the mode without changing any settings. Space-to-Sale Programming Mode If (Enter) is pressed at the prompt, the controller will enter the space-to-sales programming mode by displaying X where X is the current option selected. Using (Up or Down) will allow the operator to cycle through the available space-to-sales options and. When one of the options,, is on the display, pressing (Enter) will select that space-to-sale option and return to the prompt. If one of the option is displayed and (Abort) is pressed, the user will return to the prompt without changing any settings. For proper configuration settings refer to the label located on the inner door shear panel. Custom Space-to-Sales Mode If (Enter) is pressed at the prompt, the controller will enter the custom space-tosales programming mode by displaying XX where XX is the current selection for that certain button, alternating with either indicating that no columns are assigned to the displayed selection button or the display will scroll through a sequence of numbers that represents the columns that are currently assigned to the selection button. Using (Up or Down) will cycle through all the available selections and then. You may also choose the option of clearing all space to sales settings by pressing (Enter) at the prompt. Pressing (Abort) will go immediately to the prompt, while pressing the (Abort) button will return the controller to the prompt without changing any settings. Pressing (Enter) while the prompt. is displayed will save all changes and return the controller to Pressing (Enter) while the XX prompt is displayed will allow columns to be assigned to the current selection. The display will show nn where nn is a column number. Using (Up or Down) will cycle through all the available columns. Pressing (Enter) at any column will enter the edit mode. The display will show nnx where X will either be flashing 0 (disabled) or (enabled) to assign the columns ( nn ) to the current selection. PC-9

10 SET-UP AND CDE DESCIPTIN (CNTINUED) Using (Up or Down) will change the assignment status of the columns. Pressing (Abort) will return the controller to the nn prompt without changing the status of the column, while pressing (Enter) saves the displayed status of the column before returning to the nn prompt. Pressing (Abort) at the nnx prompt returns the controller to the prompt. EXAMPLE: nn0 = The selection is disabled. nn = The selection is enabled. Machine Configuration Mode If (Enter) is pressed at the prompt, the controller will enter the machine configuration mode by displaying X which indicates configuration options number and the X is the current status of that setting. If X is then status is active, if X is 0 then the status is not active. If (Abort) is pressed while at the X prompt the controller will return to the prompt. Pressing (Up or Down) will toggle through the available configuration options. Pressing (Enter) saves the status of the current option and returns the user to the prompt. Pressing (Abort) returns the controller to the prompt without saving. (See Figure.) EXAMPLE: 0 = The Con is disabled. = The Con is enabled. Single/Multi-Price Mode Toggles between the single-price and multi-price modes. In the single-price mode, the price of selection will be used for all selections. In the multi-price mode, each selection can be set to a different price. 0 = Single pricing is used. = Multi-pricing is used. PC-0

11 SET-UP AND CDE DESCIPTIN (CNTINUED) CN# C C C C C5 C6 CNFIGUATIN SETTINGS DESCIPTIN PICE SETTING PTINAL FEATUES PS MESSAGE D PEN MIS MIS ESET ESEVED SETTINGS 0 = SINGLE PICE = MULTI PICE 0 = DISABLE PTINAL PGAM FEATUES = ENABLE PTINAL PGAM FEATUES 0 = DISPLAY PS MESSAGE = TUN FF PS MESSAGE 0 = DISPLAY SUMMAY E CDES = DISPLAY SUMMAY SALES DATA 0 = ESET MIS VIA DEX CMMAND NLY = ESET MIS WHEN D IS CLSED C7 C8 C9 C0 C SAVE CEDIT FCE VEND MULTI VEND BILL ESCW DEPTH LEANING 0 = SAVE CEDIT F 5 MINUTES = SAVE CEDIT INDEFINITELY 0 = NMAL VEND = FCE VEND 0 = SINGLE VEND = MULTI VEND 0 = ENABLE BILL ESCW = DISABLE BILL ESCW 0 = ENABLE = DISABLE Figure ptional Feature Enable This selection will allow optional features to be enabled and displayed in the current service mode menu. If any of the optional features described in this document are implemented, they must be able to be hidden by this selection. These features currently include,, and. 0 = ption is ff. = ption is n. PC-

12 SET-UP AND CDE DESCIPTIN (CNTINUED) LED Display Message Mode Toggles between the LED display modes. In the display/led mode, the current price will be displayed if in the single price mode. Note: will scroll when the option is set at 0. 0 = Display message is n. = Display message is ff. Door pen MIS Mode This option changes the pen-door Mode Display. If enabled, the total machine sales and total machine cash value are displayed before the error codes. These values represent the number of all paid vends and the cash amount of all paid vends, respectively. The sales and cash value are displayed the same as in the and service mode functions. The display shows / 0000 / 0000 for two seconds on the display/led, then / 0000 / 00.00, then or. If this option is disabled, existing errors are displayed, or for no existing errors. 0 = Existing errors or is displayed. = / 0000 / 0000 / 0000 / and or. MIS eset Mode This option is used to allow the door switch to reset all re-settable MIS. It will be reset only if the and mode were entered. 0 = All re-settable MIS registers will be reset only when the CF command is received from the HHC. = All re-settable MIS registers are reset when the door switch is activated if any of the re-settable MIS registers are read ESEVED F FUTUE PGAMMING. PC-

13 SET-UP AND CDE DESCIPTIN (CNTINUED) Save Credit Mode This option is used to determine how long credit should be maintained on the display and available to the customer. If Save Credit is enabled it will register the credit for no more than five minutes, after the vend is aborted and returns to standby. 0 = Clears credit in five minutes. = Credit remains. Force Vend Prevents the machine from making change without a selection being attempted. When this mode is enabled, escrow of coins is allowed until any of the following: A. Any bill is inserted into the bill acceptor; B. Any cash box coin (a coin that is not assigned to a tube) is inserted, or; C. The maximum vend price is reached. nce any of these conditions are met, an escrow request is ignored and a vend must be made. If a selection is made that is sold-out or locked out, this option will be overridden and an escrow request will be honored. NTE: Force vend has no effect on the card reader. nce a card is inserted, it can always be returned to the customer via an escrow or the return switch on the card reader. 0 = Force-vend is disabled. = Force-vend is enabled. Multi-Vend Allows multiple purchases without re-entering coins. If enabled, instead of returning the change after a vend, the credit will remain on the display to be used for another selection. An escrow will be honored at any time. This option will take precedence over the forcevend option after the first vend has been completed. 0 = Multi-vend is disabled. = Multi-vend is enabled. Bill Escrow Mode Allows the escrow of bills. If enabled and the bill value inserted takes the accumulated credit over the maximum price, the bill will be held in the escrow position. If the rule is disabled, bills will always go to the stacker. 0 = Bill escrow is disabled. = Bill escrow is enabled. PC-

14 SET-UP AND CDE DESCIPTIN (CNTINUED) Learning Mode Enable Allows the learning mode for depth setting to be used. If enabled, the learning mode will activate. If disabled, the learning mode will not be activated. 0 = Learning mode is disabled. = Learning mode is enabled. Correct Change nly Control Allows the customer to disable or enable the overpay routine. If If If If, Consumer overpay routine disabled for USA., Can be enabled for International use., Correct Change Value is the value that the controller has the ability to control the Use Correct Change nly option., Unconditional Acceptance Value is the largest value of any single form of currency that can be accepted without knowledge that the equivalent value of coins can be returned. This option applies to coins or bills. Preview Vend Password Setting Mode If (Enter) is pressed at the prompt, the controller will display the current password for the preview vend mode. The first digit of the number will be flashing. Pressing (Up or Down) will adjust the currently flashing digit up or down. Pressing (Enter) will save the currently flashing digit and the next digit of the password will begin flashing. All digits may be modified in this manner. Pressing (Enter) while the last digit is flashing saves the currently displayed password and return to the prompt. Pressing (Abort) at any time in the procedure returns to the prompt without saving. Change Language If (Enter) is pressed at the prompt, the controller will display the current language for the preview mode. Pressing (Up or Down) will toggle through the available languages listed below. Pressing (Enter) will activate the displayed language and return to the prompt. Pressing (Abort) at any time in the procedure returns to the controller to the prompt without changing the active language. PC-

15 SET-UP AND CDE DESCIPTIN (CNTINUED) LANGUAGE LIST English - mandatory if supported French - mandatory if supported German - mandatory if supported Italian - mandatory if supported Portuguese - mandatory if supported Spanish - mandatory if supported Slovene - mandatory if supported Time/Date Setting Mode If (Enter) is pressed at the (time) prompt, the controller will enter the time/date setting mode and display (disable) or (enable). Using (Up or Down) will allow the controller to cycle through all available time selection options. If (Abort) is pressed anytime during this operation, the controller will return to the prompt. TIME SELECTIN PTINS Enable/Disable time (Edit mode 0/) Current Year (Example 98) Current Date (month, day) Current Month Current Time (hours, minutes) Daylight Savings Time Year Setting ption If (Enter) is pressed at the prompt, the last two digits of the year are displayed and will be flashing. Pressing (Up or Down) will increase or decrease the year setting. Pressing (Enter) will save the displayed year setting and return the user to. Pressing (Abort) will return to without saving. Month Setting ption If (Enter) is pressed at the prompt, the controller will enter the month setting option. Upon entry into this option the display will show the current two-digit month setting, indicating the month of the year (example: 0-). Pressing (Up or Down) will increase or decrease the month setting. Pressing (Enter) will save the displayed month setting and return the Controller to the prompt. Pressing (Abort) while the month digits are flashing returns to the prompt without saving the month. PC-5

16 SET-UP AND CDE DESCIPTIN (CNTINUED) Date Setting ption If (Enter) is pressed at the prompt, the current two-digit date (days of the month) is displayed. Pressing (Up or Down) will increase or decrease the date setting. Pressing (Enter) will save the displayed date and return the user to the prompt. Pressing (Abort) while the date digits are flashing returns to the prompt without saving the new date. Hour Setting ption If (Enter) is pressed at the prompt, the current time is displayed in a -hour format. The left two digits of the display show the hour and the right two digits show the current minutes. While the hour digits are flashing, pressing (Up or Down) will increase/decrease the hour. Pressing (Enter) at this point will save the displayed hours and minutes and the digits will start to flash. While the minute digits are flashing, pressing (Up or Down) will increase/decrease the minutes. Pressing (Enter) at the point will save the displayed hours and minutes and return to the prompt. Pressing (Abort) while the hour or minute digits are flashing returns to without saving the hour or minutes. Daylight Saving Time If (Enter) is pressed at the prompt, the current daylight saving time option will be displayed. Using (Up or Down) will toggle the different countries; (Australian rules), (European rules), (No daylight savings) and (North American rules). If (Enter) is pressed at this point, the current display option will be saved and the user will be returned to the prompt. Pressing (Abort) returns to the prompt without saving. Light Control If (Enter) is pressed at the prompt the controller will enter the light control programming mode by displaying (disable) or (enable). Using (Up or Down) will allow the operator to cycle through all available time selection options. If (Abort) is pressed anytime during this operation, the controller will return to the code level. LIGHT CNTL PTINS Enable/Disable light timer (Edit mode 0/) Set start time Set days to time Set time to start ( hours) Set stop time PC-6

17 SET-UP AND CDE DESCIPTIN (CNTINUED) Set Enable/Disable If (Enter) is pressed at the X prompt, the last digit of the prompt will start flashing. Pressing (Up or Down) will toggle from (Enable) to 0 (Disable). Pressing (Enter) will save the displayed setting and return the user to X. Pressing (Abort) will return to X without saving. 0 = Setting is disabled. = Setting is enabled. Start Time Setting If (Enter) is pressed at the prompt, the controller will enter the start time setting option. Upon entry into this option the display will show. Pressing (Up or Down) will cycle through the available summary level codes. Pressing (Enter) will enter the detail level option. Pressing (Abort) while a summary level prompt is displayed will return the controller to the prompt. Pressing (Abort) at the prompt will return the controller to the prompt. Day Setting ption If (Enter) is pressed at the prompt, the current day of the week is displayed. The days are displayed as follows: X Monday X Tuesday X Wednesday X Thursday X Friday X Saturday X Sunday All Days 0 = Setting is disabled. = Setting is enabled. Pressing (Up or Down) at this point will rotate through the days of the week. Pressing (Enter) when a day (e.g. X) is displayed the X will start to flash by pressing (Up or Down) will toggle from 0 (disable) to (enable). If (Enter) is pressed, the displayed day is saved and the user is returned to prompt. Pressing (Abort) returns the controller to prompt without saving. PC-7

18 SET-UP AND CDE DESCIPTIN (CNTINUED) Start Hour Setting If (Enter) is pressed at the prompt, the current time is displayed in a -hour format. The left two digits of the display will show the hour and the right two digits show the current minutes. While the hour digits are flashing, pressing (Up or Down) will increase/decrease the hour. Pressing (Enter) at this point will save the displayed hours and minutes and the digits will start to flash. While the minute digits are flashing, press (Up or Down) to increase/ decrease the minutes. Pressing (Enter) at this point will save the displayed hours and minutes and return to the Prompt. Pressing (Abort) while the hour or minutes digits are flashing returns to without saving. Set Stop If (Enter) is pressed at the prompt, the controller will enter the stop time setting option. Upon entry into this option the display will show. Pressing (Up or Down) will cycle through the available summary level codes. Pressing (Enter) will enter the detail level option. Pressing (Abort) while a summary level prompt is displayed will return the controller to the prompt. Pressing (Abort) at the prompt will return the controller to the prompt. Note: To program days and hours refer to pages 7 and 8. efrigeration Control Mode If (Enter) is pressed at the prompt, the controller will enter the refrigeration control option by displaying X indicating the enable/disable setting mode. Using (Up or Down) will allow the operator to toggle between the following modes: EFIGEATIN CNTL PTINS Enable/Disable efrigeration timer (Edit mode 0/) Set start time Set days to time Set time to start ( hours) Set stop time Set days to time Set time to start ( hours) Temperature Setting If (Enter) is pressed at the prompt, the controller will enter the refrigeration control option by displaying X indicating the enable/disable setting mode. Using (Up or Down) will allow the operator to toggle between the following modes: PC-8

19 SET-UP AND CDE DESCIPTIN (CNTINUED) TEMPEATUE CNTL PTINS Set Temperature (Edit mode Fahrenheit/Celsius) Temperature set point (Factory setting 5 F.5 C) Storage temperature setting (Factory setting 60 F 5.5 C) PS temperature display (Edit mode 0/) Fan energy conservation mode (Edit mode 0/) Defrost control (Factory setting is enabled) Degree Setting If (Enter) is pressed at the X prompt, the controller will display X where X will be if the controller is currently in ºF (Fahrenheit) mode or if the controller is currently in ºC (Celsius) mode. Pressing (Up or Down) while the X digit is flashing will toggle the X digit between and. Pressing (Enter) will save the displayed temperature mode and return the user to the X prompt. Pressing (Abort) will return to the X prompt without saving. Set Point Setting (5ºF) If (Enter) is pressed at the prompt, the controller will display XX.XX where X will be the current set point temperature. Pressing (Up or Down) will increase/decrease by one degree increments. Pressing (Enter) will save the displayed temperature setting and return the user to the prompt. Pressing (Abort) will return to the prompt without saving. Storage Temperature Setting (60ºF) If (Enter) is pressed at the prompt, the controller will display XX.XX where X will be the current storage temperature. Pressing (Up or Down) will increase/decrease by one degree increments. Pressing (Enter) will save the displayed storage temperature setting and return the user to the prompt. Pressing (Abort) will return to the prompt without saving. PC-9

20 SET-UP AND CDE DESCIPTIN (CNTINUED) Display Temperature If (Enter) is pressed at the prompt, the controller will enter into the LED temperature display enable option. Upon entry into this option the display will show the current setting where the 0 is flashing will disable the temperature from being shown in the LED or if is flashing the temperature will be displayed in the LED following. Pressing (Up or Down) will toggle the digit between 0 and. Pressing (Enter) will save the currently displayed setting and return the user to the prompt. Pressing (Abort) will return to the prompt without saving. Fan Energy Savings If (Enter) is pressed at the prompt, the controller will display where X will be 0 or. When X is 0, The evaporator shall remain on at all times. When X is, the evaporator fan will turn off 5 minutes after the compressor turns off. When the compressor comes back on, so will the evaporator. Pressing (Up or Down) while the X digit is flashing will toggle the X digit between 0 and. Pressing (Enter) will save the displayed setting and return the user to the prompt. Pressing (Abort) will return to the prompt without saving. NTE: The mode will not function for hours from the pull-down start mode. Usage of this mode requires the installation of an optional evaporator relay. Defrost Setting If (Enter) is pressed at the prompt, the controller will display where X will be 0 or. If X is 0 and the compressor has been running for more than an hour and the temperature sensor input has not dropped at least F, the controller will turn off the compressor for a period of 0 minutes. Then the controller will change the defrost mode to. When X is, the controller will turn off the compressor for a period of 0 minutes (defrost cycle) at intervals of 6 hours, after the outer door is closed. Pressing (Up or Down) while the X digit is flashing will toggle the X digit between 0 and. Pressing (Enter) will save the displayed setting and return the user to the prompt. Pressing (Abort) will return to the prompt without saving. NTE: The model will not function for 7 hours from the pull-down start mode. PC-0

21 SET-UP AND CDE DESCIPTIN (CNTINUED) Block Selection Setting If (Enter) is pressed at the or prompt, the controller will enter the blocking control options. Upon entry into this routine the display will show the first summary level code. Pressing (Enter) will save the currently displayed setting and return the user to the prompt. Pressing (Abort) will return to the prompt without saving. Using (Up or Down) will let the operator toggle between the following modes: Note: blc or blc will not be accessible when C is set at 0. 0 = Block option is disabled. = Block option is enabled. BLCK CNTL PTINS Enable/Disable selection blocking (Edit mode 0/) Set start time Set days to time Set time to start ( hours) Set stop time Set days to time Set time to stop ( hours) Set selections Discount Setting Mode If (Enter) is pressed at the prompt, the controller will enter the discount control setting blocking control routine. Upon entry into this setting the display will show the first summary level code. If (Up or Down) is pressed it will cycle through the available summary level codes as listed below. Pressing (Enter) will save the currently displayed setting and return the user to the prompt. Pressing (Abort) will return to the prompt without saving. Using (Up or Down) will let the operator toggle between the following modes: Note: disc will not be accessible when C is set at 0. 0 = Disabled discount setting. = Enabled discount setting. BLCK CNTL PTINS Enable/Disable discount setting (Edit mode 0/) Set start time Set days to time Set time to start ( hours) Set stop time Set days to time Set time to stop ( hours) Set selections Set Discount amount PC-

22 SET-UP AND CDE DESCIPTIN (CNTINUED) Selection Setting If (Enter) is pressed at the prompt, the controller will enter the selection setting option. Upon entry into this setting the display will show the current setting for selection as, where shows it is enabled or 0 if the option is disabled. If (Up or Down) is pressed it will cycle through the valid selections or. Pressing (Enter) will save the currently displayed setting and return the controller to the prompt. Pressing (Abort) will return the controller to the prompt without saving. 0 = Selection setting is disabled. = Selection setting is enabled. Selection Setting If (Enter) is pressed at the prompt, the controller will enter the discount amount option. Upon entry into this setting the display will show the current four digit discount amount. If (Up or Down) is pressed it will increase or decrease the lowest discount amount. Pressing (Enter) will save the currently displayed setting and return the user to the prompt. Pressing (Abort) will return to the prompt without saving. ver-ide ption Mode (Units equipped with optional key switch) If (Enter) is pressed at the prompt, the controller will enter the over-ride option. Upon entry into this setting the display will show the first summary level code X. If (Up or Down) is pressed it will cycle through the available summary level codes as listed below. Pressing (Enter) will save the currently displayed setting and return the user to the prompt. Pressing (Abort) will return to the prompt without saving. Using (Up or Down) will let the operator toggle between the following modes: 0 = Disabled over-ride option. = Enabled over-ride option. Note: UEr will not be accessible when C is set at 0. VEIDE SETTING PTINS Enable/Disable free vend (Edit mode 0/) Enable/Disable no vend Selection blocking over-ride Discounting over-ride Lighting control over-ride efrigeration control over-ride PC-

23 SET-UP AND CDE DESCIPTIN (CNTINUED) ver-ide Free Vend If (Enter) is pressed at the prompt, the controller will enter the free vend enable option. Upon entry into this setting the display will show the current setting. Pressing (Up or Down) will toggle between 0 (disable) or (enable). Pressing (Enter) will save the currently displayed setting and return the user to the prompt. Pressing (Abort) will return to the prompt without saving. 0 = Disabled free vend. = Enabled free vend. ver-ide No Vend If (Enter) is pressed at the prompt, the controller will enter the no vend (vend over-ride) enable routine. Upon entry into this setting the display will show the current setting. Pressing (Up or Down) will toggle between 0 (disable) or (enable). While enabled, selections will not be allowed to vend and a message will be displayed. NTE: If both the free vend and no vend features are enabled, the no vend will be given priority. ver-ide Selection Blocking If (Enter) is pressed at the prompt, the controller will enter the selection blocking over-ride enable option. Upon entry into this setting the display will show the current setting. Pressing (Up or Down) will toggle between 0 (disable) or (enable). Pressing (Enter) will save the currently displayed setting and return the user to the prompt. Pressing (Abort) will return to the prompt without saving. 0 = Disabled selection blocking. = Enabled selection blocking. ver-ide Discount If (Enter) is pressed at the prompt, the controller will enter the discounting over-ride enable option. Upon entry into this setting the display will show the current setting Pressing (Up or Down) will toggle between 0 (disable) or (enable). Pressing (Enter) will save the currently displayed setting and return the user to the prompt. Pressing (Abort) will return to the prompt without saving. 0 = Disabled discount over-ride. = Enabled discount over-ride. PC-

24 SET-UP AND CDE DESCIPTIN (CNTINUED) ver-ide Lighting Control If (Enter) is pressed at the prompt, the controller will enter the lighting control override enable option. Upon entry into this setting the display will show the current setting Pressing (Up or Down) will toggle between 0 (disable) or (enable). Pressing (Enter) will save the currently displayed setting and return the user to the prompt. Pressing (Abort) will return to the prompt without saving. 0 = Disabled lighting control. = Enabled lighting control. ver-ide efrigeration Control If (Enter) is pressed at the prompt, the controller will enter the refrigeration control over-ride enable option. Upon entry into this setting the display will show the current setting. Pressing (Up or Down) will toggle between 0 (disable) or (enable). Pressing (Enter) will save the currently displayed setting and return the user to the prompt. Pressing (Abort) will return to the prompt without saving. 0 = Disabled refrigeration control over-ride. = Enabled refrigeration control over-ride. Selection Depth Setting If (Enter) is pressed at the prompt, the controller will display where X will be the number of products that can be loaded into the depth of the columns assigned to this selection. X can be,, or. Pressing (Up or Down) while the X digit is flashing will toggle the X digit between,, or. Pressing (Enter) will save the displayed setting and return the user to the prompt. Pressing (Abort) will return to the prompt without saving. emote Vend Mechanism eserved for future technology PC-

25 PGAMMING NTES PC-5

26 . WIING DIAGAM D C A C B I L N D E T SELECTIN SWITCHES DISPLAY SEL. # CM SEL. # SEL. # SEL. # SEL. # 5 SEL. # 6 SEL. # 7 SEL. # 8 N YEL BN VI N GY YEL BN VI SEL. # 9 (WHEN USED) N SEL. # 0 (WHEN USED) GY SEL. # (WHEN USED) YEL SEL. # (WHEN USED) BN SEL. # (WHEN USED) VI PNK PNK PNK PNK PNK BLU BLU BLU BLU BLU VI N ED VI J J BN N 5 5 BLU J ED N YEL VI GY PNK J J9 B B Y G L E K N L N N 6 MDB SCKET J9 G N N W 6 W W W W 5 W S C L T V C L S C L 0 T V C L S C L 9 T V C L S C L 8 T V C L VEC. (TADE). (CKE) CNTL BAD Y E L 6 5 B B L N K BALLAST MDE SWITCH ED JA DEX SCKET BLU LAMP ' BLU LAMP ' N N ELECTNIC BULB (CKE) J J8 8 GN 7 6 GN J6 /M9 9 M/YEL BLU/M M/VI M/GY M/PNK M5/ED M6/BN M7/N /CM 6 8 M8/TAN /DS J7 0 V/GY BN/TS HEATE/VI BN/TS /VSS SHIELD/VS /VSS SHIELD/VS TAN/TS CMP/BLU FAN/YEL LIGHTS/PNK TAN/TS 8 9 DS/ LAMP ' LAMP ' LAMP ' LAMP ' ED ED BLU BLU ED ED BLU BLU YEL YEL YEL YEL BALLAST ELECTNIC BULB (TADE) BN BN TAN TAN GN D CABINET CLD CABINET WAM GN C A W B A I N M E T PC-6

27 . WIING DIAGAM VEND MTS ( VDC) D C A C B I L N D E T B B B W B T B B B B B P B G B V B Y L L L H L A L L L E L N L L I L E K U K T K N K N K N K D K K K Y K K L MT # 0 (WHEN USED) MT # 9 MT # 8 MT # 7 MT # 6 MT # 5 MT # MT # MT # MT # (WHEN USED) /VSS SHIELD/VS /VSS SHIELD/VS VS VEND SENSS VS TYPICAL MT CICUIT WITH SLDUT PTIN CM SLDUT SWITCH NC T MT VDC GEA MT GN D YEL VI GY PNK ED BN N TAN BLU C A B I N E T /DS /DS /VS SHIELD/VS /VS SHIELD/VS GN PWE DIST. BX W A M N (7) VAC TANSFME PIMAY DS/ NC N D SWITCH (D PEN) CM DS/ TEMP SENS (HEATE PTIN) YEL () VI () BLU () GY () PNK (6) N (5) PNK VAC LIGHT ELAY TEMP SENS (EFIG.) CABINET CLD CABINET WAM GY GY YEL GY () YEL () FUSE 0.8 AMP SLW BLW BLU IBBED VAC GY CMP ELAY EVAP. FAN MT M PLAIN PTINAL FAN ELAY GY VI THEMAL VELAD GN L N G L N PTINAL HEATE PTINAL HEATE ELAY VAC VAC GY PLAIN HEATE ELEMENT IBBED VI PWE CD CND. FAN MT PLAIN IBBED CMP. PLUG M VELAD STAT ELAY CABINET CLD CABINET WAM CAPACIT (0 VLT UNITS NLY) EFIGEATIN SYSTEM PC-7

28 NTES. If the outer door is left open for over an hour, the lights and compressor will become active. In order to over-ride this option, press the door switch one time. PC-8

12.1 PROGRAMMING SECTION

12.1 PROGRAMMING SECTION . PRGRAMMING SETIN PG- All programming of the V is done in the service mode as indicated in the following steps below. The main service modes are indicated in white text and the sub-modes are indicated

More information

COCA-COLA EVS REVISION 2.2 PROGRAMMING METHOD November 1998

COCA-COLA EVS REVISION 2.2 PROGRAMMING METHOD November 1998 COCA-COLA EVS REVISION 2.2 PROGRAMMING METHOD November 1998 The controller has two modes of operation: NORMAL and SERVICE. NORMAL MODE: In normal mode, on power up display will show software installed

More information

ID Dixie-Narco, Inc. P.O. Box 719 Williston, SC (800) (803) SIlO ELECTRONIC VENDERS WITH TWO BUTTON PROGRAMMING

ID Dixie-Narco, Inc. P.O. Box 719 Williston, SC (800) (803) SIlO ELECTRONIC VENDERS WITH TWO BUTTON PROGRAMMING SIlO ELECTRONIC VENDERS WITH TWO BUTTON PROGRAMMING Operation and Service Manual First Production 0773-6201CS 803,902,510.31 ID Dixie-Narco, Inc. P.O. Box 719 Williston, SC 29853 (800) 688-9090 (803) 266-5000

More information

Service Manual. 4 Button Programming. 201 Industrial Boulevard Kearneysville, WV 25430

Service Manual. 4 Button Programming. 201 Industrial Boulevard Kearneysville, WV 25430 Service Manual 4 Button Programming 201 Industrial Boulevard Kearneysville, WV 25430 CUSTOMER SERVICE: (800) 931-9214 (304) 728-7056 FAX: (304) 725-6579 R Email: Technicalinquiry@royalvendors.com Parts@royalvendors.com

More information

Model DNCB 640/448 3DVIS Beginning Production Run 5106CJ

Model DNCB 640/448 3DVIS Beginning Production Run 5106CJ Coca-Cola Model DNCB 640/448 3DVIS Beginning Production Run 5106CJ Manufactured by Crane Merchandising Systems P.O. Drawer 719 Williston, SC 29853-0719 803-266-5001 fax: 803-266-5049 Visit us on the web:

More information

General Information. Section 1. General Information INTRODUCTION FEATURES

General Information. Section 1. General Information INTRODUCTION FEATURES Section 1 General Information General Information INTRODUCTION Programming is done Menu Style with the menus consisting of Main Items and Sub-Items Figure 11 is a good example of how the menu system works

More information

OPERATION & SERVICE MANUAL VC1100 Series MDB-120 Controller Software 120 Volts, 60 HZ 230 Volts, 50 HZ

OPERATION & SERVICE MANUAL VC1100 Series MDB-120 Controller Software 120 Volts, 60 HZ 230 Volts, 50 HZ OPERATION & SERVICE MANUAL VC1100 Series MDB-120 Controller 67196-1 Software 120 Volts, 60 HZ 230 Volts, 50 HZ Seaga Manufacturing, Inc. 700 Seaga Drive, Freeport IL USA Phone: 815-297-9500 - Fax: 815-297-1700

More information

Service Manual. 4 Button Programming. 426 Industrial Boulevard Kearneysville WV USA

Service Manual. 4 Button Programming. 426 Industrial Boulevard Kearneysville WV USA Service Manual 4 Button Programming 426 Industrial Boulevard Kearneysville WV 25430-2776 USA CUSTOMER SERVICE: (800) 931-9214 (304) 728-7056 TECHNICAL SERVICE FAX: (304) 725-6579 PARTS FAX: (304) 725-4016

More information

Pepsi-Cola High Visibility Vender

Pepsi-Cola High Visibility Vender Pepsi-Cola High Visibility Vender HVV Manufactured by Models DN552P & DN756P Beginning Production Run 6925CB Dixie-Narco, Inc. P.O. Drawer 719 Williston, SC 29853-0719 803-266-5001 fax: 803-266-5049 Visit

More information

Pepsi-Cola High Visibility Vender

Pepsi-Cola High Visibility Vender Pepsi-Cola High Visibility Vender P-SERIES HVV Models DN504PHV-6 & DN720PHV-12 Beginning Production Run 7675AE Manufactured by Dixie-Narco, Inc. P.O. Drawer 719 Williston, SC 29853-0719 803-266-5001 fax:

More information

6.0 SERVICE PROGRAMMING

6.0 SERVICE PROGRAMMING 6.0 SERVICE PROGRAMMING SERVICE MODE Access the service mode by pressing the mode switch on the control board (refer to Figure 3.1). After displaying any errors, the first function is displayed. Press

More information

Pepsi-Cola High Visibility Vender

Pepsi-Cola High Visibility Vender Pepsi-Cola High Visibility Vender Models DNCB 640, DNCB 448 Beginning Production Run 5206CK Manufactured by Crane Merchandising Systems P.O. Drawer 719 Williston, SC 29853-0719 803-266-5001 fax: 803-266-5049

More information

KM SERIES VENDING MACHINES OPERATION MANUAL

KM SERIES VENDING MACHINES OPERATION MANUAL KM SERIES VENDING MACHINES OPERATION MANUAL 1 Main Board & Driver Board MAIN BOARD DRIVER BOARD 2 Selection Keypad Old Keypad New Keypad 1. In the Standby Mode, here are the roles of the available Function

More information

UTB-400c INSTALLATION AND OPERATION GUIDE COINCO UTB 400-C TEST BOX

UTB-400c INSTALLATION AND OPERATION GUIDE COINCO UTB 400-C TEST BOX UTB-400c INSTALLATION AND OPERATION GUIDE COINCO UTB 400-C TEST BOX The UTB 400-C is a fully functional Vending machine simulator with configurable settings. It supports MDB, Executive and BDV protocol

More information

Manufactured by 803,903,120.21

Manufactured by 803,903,120.21 Pepsi-Cola High Visibility Vender For HT2 Venders Produced Beginning Production Run 6730BZ For HT3 Venders Produced Beginning Production Run 6757DZ For HT3 Tier 1 Energy Star Venders Produced Beginning

More information

GIII Plus. Royal Vendors, Inc. Operation and Service Manual

GIII Plus. Royal Vendors, Inc. Operation and Service Manual R Royal Vendors, Inc. GIII Plus Operation and Service Manual Manufactured by Royal Vendors, Inc. 46 Industrial Boulevard Kearneysville WV 540-776 USA Telephone + 04 78 7056 Fax + 04 75 406 technicalinquiry@royalvendors.com

More information

Glass Front Vender by Maytag

Glass Front Vender by Maytag Glass Front Vender by Maytag Manufactured by Dixie-Narco, Inc. P.O. Drawer 719 Williston, SC 29853-0719 800-688-9090 803-266-5001 fax: 803-266-5049 Visit us on the web: www.dixienarco.com 803,903,030.41

More information

Dr. Pepper SL5 E Model Vender For DPSL5 E Model Venders Produced Beginning Production Run 6907CB Manufactured by

Dr. Pepper SL5 E Model Vender For DPSL5 E Model Venders Produced Beginning Production Run 6907CB Manufactured by Dr. Pepper SL5 E Model Vender For DPSL5 E Model Venders Produced Beginning Production Run 6907CB Manufactured by Dixie-Narco, Inc. 11685 Main Street Williston, SC 29853-0719 803-266-5001 fax: 803-266-5049

More information

EX2000 Series Vending System. User s Manual. Choose ACDI for all your document vending needs User s Manual

EX2000 Series Vending System. User s Manual. Choose ACDI for all your document vending needs User s Manual EX2000 Series Vending System User s Manual Choose ACDI for all your document vending needs User s Manual INTRODUCTION... 1 OVERVIEW... 1 Staff Copies... 1 SETUP... 2 UNPACKING THE VENDING SYSTEM... 2

More information

MDB Coin Changer and MDB Bill Acceptor to RS 232 Interface

MDB Coin Changer and MDB Bill Acceptor to RS 232 Interface Shanghai Wafer Microelectronics Co., Ltd. 23E,Liang Feng Building,NO.8,DongFang Road,Shanghai,China Tel.: (0086)21 5187 0528 Fax: (0086)21 5045 4820 MDB Coin Changer and MDB Bill Acceptor to RS 232 Interface

More information

EX2000 Series Vending System. User s Manual. Choose ACDI for all your document vending needs User s Manual

EX2000 Series Vending System. User s Manual. Choose ACDI for all your document vending needs User s Manual EX2000 Series Vending System User s Manual Choose ACDI for all your document vending needs User s Manual INTRODUCTION... 1 OVERVIEW... 1 Staff Copies... 1 SETUP... 2 UNPACKING THE VENDING SYSTEM... 2

More information

Dexter Washer Programing. Part # 8533-***-*** 03/14

Dexter Washer Programing. Part # 8533-***-*** 03/14 Dexter Washer Programing 3 PROGRAMMING INSTRUCTIONS: The washer control can be programmed to prompt the user for alternate vend prices, change washer cycle times, temperatures and many other options. This

More information

ESDI Model A MDB MultiPrice Water Vend Controller Operation and Installation Manual

ESDI Model A MDB MultiPrice Water Vend Controller Operation and Installation Manual ESDI Model 110100-A MDB MultiPrice Water Vend Controller Operation and Installation Manual (Also see Programming & Service Manual) WARNING! ELECTRICAL SHOCK HAZARD! AUTHORIZED PERSONNEL ONLY. EXPOSED 120

More information

E V W M - 14 OLD FAITHFUL

E V W M - 14 OLD FAITHFUL 44 1/2 E V W M - 14 OLD FAITHFUL Ve ndor 23 5/8 I n s t r uc t i o n Ma n ua l V1.0 Etowah Valley Equipment Inc. 47 Etowah Center Dr. Etowah, N.C. 28729 Shop/Tech Support (828) 891-7768 Toll Free 1-888-920-2646

More information

Merlin IV NG. Royal Vendors, Inc. Operation and Service Manual

Merlin IV NG. Royal Vendors, Inc. Operation and Service Manual R Royal Vendors, Inc. Merlin IV NG Operation and Service Manual Manufactured by Royal Vendors, Inc. 6 Industrial Boulevard Kearneysville WV 0-776 USA Telephone + 0 78 86 Fax + 0 7 06 technicalinquiry@royalvendors.com

More information

Stacked Commercial Dryer Programing

Stacked Commercial Dryer Programing Stacked Commercial Dryer Programing 1/3/18 DexterLive The new DexterLive controls were created for you to be able to interface easier with your equipment and create variable pricing cycles to increase

More information

SERVICE and PARTS MANUAL

SERVICE and PARTS MANUAL Ambient and Refrigerated Models SERVICE and PARTS MANUAL Revision 2.EL950 1.3.1074C 18.2 1 INTRODUCTION Congratulations on the purchase of your vending machine. This vending machine has been designed to

More information

Merlin IV. Royal Vendors, Inc. Manufactured by. 426 Industrial Boulevard Kearneysville WV USA

Merlin IV. Royal Vendors, Inc. Manufactured by. 426 Industrial Boulevard Kearneysville WV USA R o y a l V e n d o r s, I n c. Merlin IV S e r v i c e a n d P a r t s M a n u a l Manufactured by R Royal Vendors, Inc. 6 Industrial Boulevard Kearneysville WV 0-776 USA Telephone + 0 78 706 Fax + 0

More information

EASYVEND Series 5 CONTROL BOARD SPECIFICATION (P213)

EASYVEND Series 5 CONTROL BOARD SPECIFICATION (P213) Page 1 EASYVEND Series 5 CONTROL BOARD SPECIFICATION (P213) ISSUE B File : EasyVend Series 5 VMC Specification B.doc Changes: Issue Date Changes A 18 May 2009 Initial Release B 31 May 2009 Connector References

More information

Instruction Guide: HydroZone Controller

Instruction Guide: HydroZone Controller Instruction Guide: HydroZone ontroller Instruction Guide: HydroZone ontroller Installation Instructions The WaterFurnace HydroZone controller is a part of the hydronic heat pump system. The WaterFurnace

More information

ACW-5 Operational Manual

ACW-5 Operational Manual ACW-5 Operational Manual Document #101-0044 12/27/02 PLEASE READ THIS MANUAL CAREFULLY PRIOR TO INSTALLING THIS UNIT. A complete understanding of the operation of this unit is essential for a successful

More information

RVV Gen II. Royal Vendors, Inc. RVV Generation II with KO Programming Operation and Service Manual

RVV Gen II. Royal Vendors, Inc. RVV Generation II with KO Programming Operation and Service Manual Royal Vendors, Inc. RVV Gen II RVV Generation II with KO Programming Operation and Service Manual Manufactured by Royal Vendors, Inc. Industrial Boulevard Kearneysville WV 0-77 USA R Telephone + 0 78 70

More information

RVV NG / RVV NG PLUS Royal Vision Vender - Next Generation

RVV NG / RVV NG PLUS Royal Vision Vender - Next Generation R o y a l V e n d o r s, I n c. RVV NG / RVV NG PLUS Royal Vision Vender - Next Generation O p e r a t i o n a n d S e r v i c e M a n u a l 0 VAC 0 Hz models with KO Programming Manufactured by Customer

More information

3000 CONTROLLER TRAINING MANUAL. April 26, 2012 Software Version

3000 CONTROLLER TRAINING MANUAL. April 26, 2012 Software Version 3000 CONTROLLER TRAINING MANUAL April 26, 2012 Software Version 1.59.03 Contents 3000 CONTROLLER USER GUIDE Quick Reference: Using the 3000... 3 Menu Summary Tree... 6 Main Menu: Programming your Fryer...

More information

A m e r i c a n C h a n g e r

A m e r i c a n C h a n g e r A m e r i c a n C h a n g e r 1400 NW 65 TH Place Ft. Lauderdale, FL 33309 AC7700/7800 BILL TO BILL SERIES CHANGER OPERATIONS MANUAL Parts & Service: (954)917-5963 Service Fax: (954)917-5204 Sales: (800)741-9840

More information

Glassfront Vender Production BH & higher

Glassfront Vender Production BH & higher Glassfront Vender Production 8900-0001BH & higher Tier 2 Operation Service Parts Troubleshooting Manual Manufactured by Dixie-Narco, Inc. P.O. Drawer 719 Williston, SC 29853-0719 803-266-5001 fax: 803-266-5049

More information

Glass Front Vender by Maytag DN5000 Beginning Production Run 8063BY DN3000 Beginning Production Run 8292DB

Glass Front Vender by Maytag DN5000 Beginning Production Run 8063BY DN3000 Beginning Production Run 8292DB Glass Front Vender by Maytag DN5000 Beginning Production Run 8063BY DN3000 Beginning Production Run 8292DB Manufactured by Dixie-Narco, Inc. P.O. Drawer 719 Williston, SC 29853-0719 803-266-5001 fax: 803-266-5049

More information

POCKET GUIDE ROUTINE MAINTENANCE, SAFETY, INSTALLATION & TROUBLESHOOTING

POCKET GUIDE ROUTINE MAINTENANCE, SAFETY, INSTALLATION & TROUBLESHOOTING The 350 REFERENCE SERIES MULTI-PRICE TOTALISER POCKET GUIDE ROUTINE MAINTENANCE, SAFETY, INSTALLATION & TROUBLESHOOTING CashFlow CashFlow CashFlow C ashflow CashFlow CashFlow Cas hflow CashFlow CashFlow

More information

Operational Manual for the ACW-5-D

Operational Manual for the ACW-5-D Operational Manual for the ACW-5-D Document #101-0069 Page 1 of 92 12/27/02 PLEASE READ THIS MANUAL CAREFULLY PRIOR TO INSTALLING THIS UNIT. A complete understanding of the operation of this unit is essential

More information

Instructions. Installation and Operation of the Prodigy Smart-Board, KSBU

Instructions. Installation and Operation of the Prodigy Smart-Board, KSBU Instructions Installation and Operation of the Prodigy Smart-Board, KSBU Scotsman's Advanced Feature Smart-Board is an optional add on electronic device that can be applied to most Prodigy models, either

More information

Validator Update Instructions for Rowe BC1200 $1 - $20

Validator Update Instructions for Rowe BC1200 $1 - $20 Validator Update Instructions for Rowe BC1200 $1 - $20 Kit Overview The purpose of the kit is to replace the Rowe BA50 transport and stacker with a 120 volt Mars validator with a compact mask. The kit

More information

Phase 8.3 and 8.4 Rev 2.2 and Rev 2.3 Microprocessor User s Manual

Phase 8.3 and 8.4 Rev 2.2 and Rev 2.3 Microprocessor User s Manual Phase 8.3 and 8.4 Rev 2.2 and Rev 2.3 Microprocessor User s Manual Retain This Manual In A Safe Place For Future Reference IMPORTANT NOTE TO PURCHASER Table of Contents General User Information Coin/Debit

More information

Instructions. Installation and Operation of the Prodigy Smart-Board, KSBU-N

Instructions. Installation and Operation of the Prodigy Smart-Board, KSBU-N Instructions Installation and Operation of the Prodigy Smart-Board, KSBU-N Scotsman's Advanced Feature Smart-Board is an optional add on electronic device that can be applied to most Prodigy models, either

More information

NKL CX Series. Customer Manual. Version /23/2012 P/N

NKL CX Series. Customer Manual. Version /23/2012 P/N NKL CX Series Customer Manual Version 1.1 02/23/2012 P/N 15239005 Table of Contents Introduction... 3 Technical Support... 3 Screen Types... 4 Standard Keypad Display... 4 Touch Screen Display... 5 CX

More information

IVS 2.0 Software Manual for Air, Vac & Water Machines

IVS 2.0 Software Manual for Air, Vac & Water Machines IVS 2.0 Software Manual for Air, Vac & Water Machines Development Draft Ver. 7.13.07 Table of Contents PREFACE...1 CHAPTER 1-INCORPORATING IVS 2.0 INTO YOUR BUSINESS...2 Overview... 2 Menu Selections...

More information

Instructions. Installation and Operation of the Prodigy Smart-Board, KSB

Instructions. Installation and Operation of the Prodigy Smart-Board, KSB Instructions Installation and Operation of the Prodigy Smart-Board, KSB Scotsman's Advanced Feature Smart-Board is an optional add on electronic device that can be applied to most Prodigy models. It can

More information

AMERICAN CHANGER & HOFFMAN MINT. We Are Changing the Industry

AMERICAN CHANGER & HOFFMAN MINT. We Are Changing the Industry AMERICAN CHANGER & HOFFMAN MINT We Are Changing the Industry 1400 N. W. 65 th Place, Fort Lauderdale, Florida 33309 T: (+1) 954-917-3009 F: (+1) 954-917-3079 www.americanchanger.com www.hoffmanmint.com

More information

The UP and DOWN buttons will toggle or scroll through the options in each section.

The UP and DOWN buttons will toggle or scroll through the options in each section. TECHNICAL BULLETIN: MWR-WE10, MWR-WE10N, MWR-WE11N Page 1 of 10 Throughout the scheduling process, the LEFT and RIGHT buttons will move forward and backward through each section of settings The UP and

More information

Instructions. Installation & Operation of the Prodigy Smart-Board, KSBU-N

Instructions. Installation & Operation of the Prodigy Smart-Board, KSBU-N Instructions Installation & Operation of the Prodigy Smart-Board, KSBU-N Scotsman's Advanced Feature Smart-Board is an optional add on electronic device that can be applied to most Prodigy models. It can

More information

Coin Manager CN MDB Installation Guide-Canada. Set Up Screen Features (Continued) GENERAL INFORMATION

Coin Manager CN MDB Installation Guide-Canada. Set Up Screen Features (Continued) GENERAL INFORMATION Set Up Screen Features (Continued) Fig.18 Coin Manager 7512 CN MDB Installation Guide-Canada GENERAL INFORMATION To View errors - Press the yellow mode button (highlighted View ) to gain access. Use the

More information

Manual. Water Vend Controller Model ESDI WARNING! ELECTRICAL SHOCK HAZARD! AUTHORIZED PERSONNEL ONLY. EXPOSED 120 VAC ON CIRCUIT BOARD

Manual. Water Vend Controller Model ESDI WARNING! ELECTRICAL SHOCK HAZARD! AUTHORIZED PERSONNEL ONLY. EXPOSED 120 VAC ON CIRCUIT BOARD Manual Water Vend Controller Model ESDI 030400 WARNING! ELECTRICAL SHOCK HAZARD! AUTHORIZED PERSONNEL ONLY. EXPOSED 120 VAC ON CIRCUIT BOARD THE CIRCUIT BOARD HAS MANY EXPOSED AREAS THAT ARE AT 120 VAC.

More information

1.0 EF MODULE BASIC INSTRUCTIONS...

1.0 EF MODULE BASIC INSTRUCTIONS... Contents 1.0 EF MODULE BASIC INSTRUCTIONS... 1 NAVIGATING THE AVAILABLE MENUS...1 MAIN MENU DESCRIPTIONS & MENU NAVIGATION...2 REPORTING AND PRINTING FEATURES...3 NAVIGATING THE MAIN MENU LIST...4 ACCEPT

More information

The MDB2USB User's Guide Version 1.00

The MDB2USB User's Guide Version 1.00 The MDB2USB User's Guide Version 1.00 Multi-Drop Bus (MDB) to Interface Upstate Networks Inc. 1001 Broad Street Utica, New York 13501 USA OVERVIEW... 5 LICENSE... 6 QUICK START... 8 HARDWARE INSTALLATION...

More information

U-FLASH Setup Guide U-FLASH.

U-FLASH Setup Guide U-FLASH. U-FLASH Setup Guide Thank you for purchasing the U-FLASH. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,

More information

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs

More information

PROGRAMMING MANUAL 120 SELECT CONTROLLER SOFTWARE VENDOR MODEL SOFTWARE COMBO 3/6 3155, 3155A , 3157A 3158, 3158A 3159, 3159A

PROGRAMMING MANUAL 120 SELECT CONTROLLER SOFTWARE VENDOR MODEL SOFTWARE COMBO 3/6 3155, 3155A , 3157A 3158, 3158A 3159, 3159A PROGRAMMING MANUAL 120 SELECT CONTROLLER SOFTWARE This manual contains only the programming instructions for the 120 Select Controller used on the vending machines listed below. Please refer to your service

More information

Thomas. Change Machine. Operator Guide

Thomas. Change Machine. Operator Guide Thomas 5002 Change Machine Operator Guide Contents On Receiving Your New Change Machine...3 Coin Mech Installation...3 Fitting...3 Removing...3 Opening...3 Switching On...4 Machine Alarm and Alarm Keyswitch

More information

Interface MDB SLAVE to RS232 v Quick reference

Interface MDB SLAVE to RS232 v Quick reference Interface MDB SLAVE to RS232 v07.06.2017 Quick reference Table of Contents I. Hardware overview...3 1. Power supply requirements...3 2. Connector description...3 3. General description...3 II. RS232 communication

More information

TACC Parts List Description

TACC Parts List Description 644-0037-003S AC ADAPTER, THERMAL PRINTER 83.49 FOR CII & IV WITH THERMAL PRINTER ONLY. Does not include power cord. 00050103S ANCHOR KIT 25.71 Includes 4 anchors, bolts and washers. Requires 5/8" masonry

More information

Simplified Operating Instructions T105-C / T108-C / T106-C / T17B-C DISPLAYS DAY OR DAY BLOCK PROG 00:0000 PROG PROG ALWAYS OFF

Simplified Operating Instructions T105-C / T108-C / T106-C / T17B-C DISPLAYS DAY OR DAY BLOCK PROG 00:0000 PROG PROG ALWAYS OFF Button Operations Simplified Operating Instructions T105-C / T108-C / T106-C / T17B-C R - Reset (with pen or other pointed instrument). Y - Enters function setup. +/- Buttons to scroll through icons. Y

More information

Glassfront BevMax 3 Vender Model DN CF and higher

Glassfront BevMax 3 Vender Model DN CF and higher Glassfront BevMax 3 Vender Model DN5800 0001-8600CF and higher Operation Service Parts Troubleshooting Manual Manufactured by Dixie-Narco, Inc. P.O. Drawer 719 Williston, SC 29853-0719 803-266-5001 fax:

More information

Section 7 Cashless Device(s) VMC/Peripheral Communication Specifications

Section 7 Cashless Device(s) VMC/Peripheral Communication Specifications Section 7 Cashless Device(s) VMC/Peripheral Communication Specifications 7.1 Introduction This section defines the communications bytes sent and received between the cashless device(s) and the Vending

More information

Operating Instructions

Operating Instructions Technical Documentation Operating Instructions Coin changer 02.08 Goe/Schn/G-JM Edition 1.0 KA.C 2 -GB National Rejectors, Inc. GmbH Zum Fruchthof 6 D-21614 Buxtehude Phone: +49 (0)4161-729-0 Fax: +49

More information

sbdconfig.exe Software

sbdconfig.exe Software Installing the Please Note: The software only works with the 3200 or 3300 digital clocks series. Sapling s USB to RS485 converter needs to be purchased separately. Other USB to RS485 converters will not

More information

A m e r i c a n C h a n g e r OPERATIONS MANUAL MODEL AC2207. ARL Listed STD: UL 756

A m e r i c a n C h a n g e r OPERATIONS MANUAL MODEL AC2207. ARL Listed STD: UL 756 A m e r i c a n C h a n g e r 1400 NW 65 TH Place Ft. Lauderdale, FL 33309 TOKENSTATION CHANGER OPERATIONS MANUAL MODEL AC2207 ARL Listed STD: UL 756 Parts & Service: (888)741-9840 Service Fax: (954)917-5204

More information

SIID ELECTRONIC VENDERS

SIID ELECTRONIC VENDERS SIID ELECTRONIC VENDERS WITH TWO BUTTON PROGRAMMING DIXIE-NARCO, INC. Operation and Service Manual First Production 0773-6201CS September 1994 Revised 7/15/99 803,902,510.31 Dixie-Narco, Inc. P.O. Box

More information

Blu-ray/DVD/CD Duplicator Control Manual. User s Manual

Blu-ray/DVD/CD Duplicator Control Manual. User s Manual Blu-ray/DVD/CD Duplicator Control Manual User s Manual 0 TABLE OF CONTENTS Introduction 2 Setup 12 LCD Front Panel Overview 2 o Auto Start Time 12 HDD Manager o Select Image o Disc => Controller Connection

More information

Dexter Washer C-Series Programing. Part # 8533-***-*** 03/14

Dexter Washer C-Series Programing. Part # 8533-***-*** 03/14 Dexter Washer C-Series Programing 1 DexterLive The new DexterLive controls were created for you to be able to interface easier with your equipment and create variable pricing cycles to increase your profitibility

More information

To view the last sale paid out or previous sale, select a fueling position and hold the * (asterisks, or star) button.

To view the last sale paid out or previous sale, select a fueling position and hold the * (asterisks, or star) button. EZ Config - This is the same software TMS uses to connect remotely from our factory. This a free software program that is required to program the EZ console, either with a direct connection from a PC via

More information

User s Guide January Telemecanique Zelio-Logic. Smart Relay

User s Guide January Telemecanique Zelio-Logic. Smart Relay User s Guide January 2000 Telemecanique Zelio-Logic Smart Relay Preliminary Advice on Installing Smart Relays Power down the device. Take all necessary measures to avoid unwanted relay triggering. Check

More information

FlexPak 3000 Drive Operator Interface Module (OIM) User s Guide

FlexPak 3000 Drive Operator Interface Module (OIM) User s Guide FlexPak 3000 Drive Operator Interface Module (OIM) User s Guide Instruction Manual D2-3344 The information in this manual is subject to change without notice. Throughout this manual, the following notes

More information

Jofemar S.A. (31350 Peralta (Navarra, Spain)) Tel Fax

Jofemar S.A. (31350 Peralta (Navarra, Spain)) Tel Fax Jofemar Jofemar S.A. (31350 Peralta (Navarra, Spain)) Tel. 34-948-751-212 Fax 34-948-750-143 Code: MNP38V03GBV00 Date: June 2001 Page 1 of 29 Table of Contents 1. DESCRIPTION OF THE MACHINE.... 3 1.1 -

More information

Programming Manual for the vending machine model "EuroSnacky"

Programming Manual for the vending machine model EuroSnacky Programming Manual for the vending machine model "EuroSnacky" VERS. SOFTWARE E1.00 CONTENTS 1.1 INTRODUCTION...2 1.2 PROGRAMMING MODE...2 1.3 COUNTER OF DISPENSED PRODUCTS...3 1.4 PRICE SETTING...4 1.5

More information

ML Multi Stage Thermostat Installation & User Guide

ML Multi Stage Thermostat Installation & User Guide ML Thermostat PR0122-STA PR0123-STA ML Multi Stage Thermostat Installation & User Guide For Products: - PR0710, PR0711, PR0720, PR0721 Resource Data Management Ltd 80 Johnstone Avenue, Hillington Industrial

More information

1.0 EF+ MODULE BASIC INSTRUCTIONS

1.0 EF+ MODULE BASIC INSTRUCTIONS P.O. Box 36550 Indianapolis, IN 46236-0550 3130 N. Mitthoeffer Rd. Indianapolis, IN 46235-0550 (317) 899-6966 FAX (317) 899-6977 WEB:www.standardchange.com Instruction Manual 8M00617 REV. 2 - 2 - Contents

More information

Daikin HVAC Controls Guide Specification

Daikin HVAC Controls Guide Specification Part 1 - General VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM Advanced Multi-zone Controller 1.01. Physical characteristics A. General: The advanced multi-zone controller shall be made from plastic materials

More information

Gold Line ACW Operational Manual

Gold Line ACW Operational Manual Gold Line ACW Operational Manual Document #101-0041 1 7/16/04 TABLE OF CONTENTS I. INTRODUCTION... 7 Features:... 7 Options:... 7 II. INSTALLATION... 9 MECHANICAL INSTALLATION... 9 Unpacking... 9 Positioning...

More information

TC-9102 Series Surface Mount Temperature Controllers

TC-9102 Series Surface Mount Temperature Controllers TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may

More information

QW-5953 Credit Card Ready Wash Entry System

QW-5953 Credit Card Ready Wash Entry System QW-5953 Credit Card Ready Wash Entry System Instruction Manual Phone +64 3 338-3139, Fax +64 3 338-3725, Anztec Ltd, PO Box 3288, Christchurch, New Zealand www.anztec.com email sales@anztec.com Page 1

More information

SMART POOL BOARD APPLICATIONS GUIDE

SMART POOL BOARD APPLICATIONS GUIDE ART POOL BOARD APPLICATION GUIDE IUE A 18 February 2006 File : ART POOL Applications Guide.doc s: Issue Date s A 18/2/06 Original Issue 2005 JCA ystems Ltd Page 1 ART POOL The ART POOL board (P) is a new

More information

Slim Line Snack Vendor

Slim Line Snack Vendor Slim Line Snack Vendor 1 Operator s Manual INTRODUCTION Congratulations on the purchase of your vending machine. This vending machine has been designed to give you many years of dependable service. It

More information

ACS850 User s Guide ACS850 Control Panel

ACS850 User s Guide ACS850 Control Panel ACS850 User s Guide ACS850 Control Panel ACS850 Control Panel User s Guide 3AUA0000050277 Rev A EN EFFECTIVE: 02.01.2009 2009 ABB Oy. All Rights Reserved. 5 Table of contents Table of contents About the

More information

INSTRUCTION MANUAL FOR VEND-MASTER & VEND-MASTER VALIDATOR

INSTRUCTION MANUAL FOR VEND-MASTER & VEND-MASTER VALIDATOR INSTRUCTION MANUAL FOR VEND-MASTER & VEND-MASTER VALIDATOR Dilling-Harris, Inc. 10215 Miller Rd., Dallas, Texas 75238 Tel: (214)348-2662 Fax: (214)348-2914 Table of Contents Subject Page IMPORTANT WALL

More information

ACD3000 Series Vending Card System. User s Manual. Choose ACDI for all your document vending needs User s Manual

ACD3000 Series Vending Card System. User s Manual. Choose ACDI for all your document vending needs User s Manual ACD3000 Series Vending Card System User s Manual Choose ACDI for all your document vending needs User s Manual INTRODUCTION... 1 OVERVIEW... 1 Staff Copies... 1 SETUP... 2 UNPACKING THE VENDING SYSTEM...

More information

Touchpad User Guide. National Sales. Product Support. Freecall: Ph:

Touchpad User Guide. National Sales. Product Support. Freecall: Ph: Touchpad User Guide National Sales Ph: 1300 306 125 sales@ias.net.au Product Support Freecall: 1800 354 434 support@ias.net.au Designed and Manufactured in Australia by: Innovative Air Systems Pty Ltd.

More information

76 F. Ductless Split Air Conditioner. YR-E16b Wired Controller User Manual WARNING

76 F. Ductless Split Air Conditioner. YR-E16b Wired Controller User Manual WARNING Ductless Split Air Conditioner YR-E16b Wired Controller User Manual Set temp. 76 F Indoor temp. 70 F Indoor humidity 32%RH Qty. online Standby Defrost Master Outdoor temp. 36 F Outdoor humidity 32%RH Mode

More information

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer Model: 92000-01 THE STANDARD IN PRECISION MEASUREMENT Table of Contents Introduction... 3 Unpacking... 3 Initial Setup...3

More information

Product Manual SZ2141

Product Manual SZ2141 Product Manual SZ11 Refrigeration Controller Communicating Controls Description The SZ11 is a microprocessor-based refrigeration controller and alarm interface designed to control three coolers or freezers

More information

Zodiac Link QUICKSTART GUIDE

Zodiac Link QUICKSTART GUIDE Zodiac Link QUICKSTART GUIDE May 2014 Table of Contents Step 1 Enroll Administrator... 3 Step 2 Set Mode... 3 Step 3 Set Slaves... 4 Step 4 Map Slaves... 4 Step 5 Set Reader Clock... 4 Step 6 - Synchronize

More information

V0STAT51P-2 Programmable Wired Controller

V0STAT51P-2 Programmable Wired Controller PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF V0STAT51P-2 Programmable Wired Controller Bulletin No. 210766 March 2016 Grouping - Controller can control up to 16 indoor units on the same

More information

GS Cash Card Loader

GS Cash Card Loader GS 1085 Cash Card Loader May 2007 Table of Contents SALES AND SERVICE... 3 QUICK REFERENCE SET-UP GUIDE. 4 FUNCTIONAL OVERVIEW... 6 INSTALLATION - SETUP... 8 IDENTIFYING THE COMPONENTS... 9 SETUP THROUGH

More information

Version: Draft Date: 12/28/ :45:00 AM

Version: Draft Date: 12/28/ :45:00 AM Weavefuture Internet Café, Cyber Café Self Service Payment System Version: Draft Date: 12/28/2006 12:45:00 AM Table of Contents 1 WEAVEFUTURE INTERNET CAFÉ CYBER CAFÉ SELF SERVICE PAYMENT SYSTEM 3 2 WEAVEFUTURE

More information

Use of the application program. Table of Contents. GAMMA instabus Application program description. April B0 CO Room Control Unit

Use of the application program. Table of Contents. GAMMA instabus Application program description. April B0 CO Room Control Unit Use of the application program Product family: Product type: Manufacturer: Displays Display and operating units Siemens AG Name Room control unit UP 227 DELTA i-system Order no.: Table of Contents 5WG1

More information

RS3000 SERIES BILL ACCEPTORS

RS3000 SERIES BILL ACCEPTORS Flash Diagnostic Codes RS3000 SERIES BILL ACCEPTORS INSTALLATION GUIDE s of the bill acceptor. Below is a chart that lists all the flash codes of the RS3000 Bill Acceptor and a description of each code.

More information

Dryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51

Dryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51 Dryer M720 Programming and Operation Manual July 15, 2015 Revision 1.51 Contents 1 Important Safety Information 1 1.1 FOR YOUR SAFETY - CAUTION!............................. 1 2 Control Overview 2 2.1

More information

MEI CASHFLOW 7000 SERIES CHANGE MANAGER ENGINEERS HANDBOOK

MEI CASHFLOW 7000 SERIES CHANGE MANAGER ENGINEERS HANDBOOK MEI CASHFLOW 7000 SERIES CHANGE MANAGER ENGINEERS HANDBOOK MEI, 2006 Page 1 Rev: G5 MEI Cashflow 7000 Series Change Manager Engineers Handbook This edition (April 2006) Printed in the United Kingdom. Internet:

More information

INTERNATIONAL SERVICE BULLETIN - I #6-203 CAW-IV Program , Rev. Y. The field requires current information on CAW-IV program

INTERNATIONAL SERVICE BULLETIN - I #6-203 CAW-IV Program , Rev. Y. The field requires current information on CAW-IV program RYKO Manufacturing Company 11600 N.W. 54th Ave. P.O.Box 38 Grimes, Iowa 50111 Phone (515) 986-3700 www.ryko.com Fax (515) 986-3621 sales@ ryko.com 22 July 2006 April 2003 INTERNATIONAL SERVICE BULLETIN

More information

ADVANCED OPERATOR PANEL (AOP)

ADVANCED OPERATOR PANEL (AOP) ADVANCED OPERATOR PANEL (AOP) Operating Instructions Issue 04/02 English Contents 1 Warnings and Notes 3 1.1 Special Key Functions 4 2 Applications Examples 4 2.1 Single drive control using the AOP 4 2.2

More information

S a f e t y I n s t r u c t i o n s

S a f e t y I n s t r u c t i o n s O P E R A T O R S M A N U A O P E R A T O R S M A N U A L L S a f e t y I n s t r u c t i o n s When using your heat press, basic precautions should always be followed, including the following:.. 3. 4.

More information

Quick installation guide

Quick installation guide Quick installation guide Subject Ref. No. Vers. Ziehl Abegg EC-Blue motors quick configuration guide 1.0 1 / 3 Issued by Department D. Rizzotti Air Business Center Approved by Location Date 23/05/2013

More information