1 C Examcollection.Premium.Exam.52q Number: C Passing Score: 800 Time Limit: 120 min File Version: Exam Code: C Exam Name: Power Systems Enterprise Technical Support for AIX and Linux -v2

2 Certkiller QUESTION 1 Which power reduction technology requires a software component in order to be activated? A. Power capping B. Processor folding C. Static power saving D. Processor core nap mode /Reference: QUESTION 2 Which of the following commands will enable the SEA accounting? A. chacct -dev ent14 -attr enable B. optimizenet -set accounting=enabled C. chsea -dev ent14 -attr accounting=enable D. chdev -dev ent14 -attr accounting=enabled /Reference: QUESTION 3 A company which sells books and DVDs runs their business on AIX Enterprise Edition on a Power 795. They have LPARs running back-office applications and other LPARs supporting their Internet based retail operations. They are considering a policy of switching between TurboCore mode and MaxCore mode, depending on workload. Which of the following considerations will have the most impact on the customer's business? A. The managed system will need to be restarted to change modes. B. There will be fewer cores available when using TurboCore mode. C. There will be less L3 cache available per core when using MaxCore mode. D. The applications running on the affected LPARs must support MaxCore and TurboCore modes. /Reference: QUESTION 4 An administrator attempts to migrate a running LPAR using the 'migrlpar' command. :

3 What task will help the administrator determine the cause of the errors? A. Validate the configured attributes on the Properties tab of the LPAR profile. B. Validate that the VIO servers have the Mover Service Partition (MSP) attribute set. C. Validate that the required CPU entitlements are available on the destination server. D. Validate that the Logical Memory Block (LMB) size is consistent between both source and destination. /Reference: QUESTION 5 All Power 795 system racks must have door assemblies installed. Three distinct door styles are available. One of the options - the acoustical door kit - reduces the noise emissions from the system. What attributes are improved by the other 2 door styles? A. Weight, height B. Depth, security C. Depth, temperature D. Height, temperature Correct Answer: C /Reference: QUESTION 6 Which was the first release of IBM i to support Multipath I/O (MPIO) at the client LPAR level, when the same storage is served from redundant VIO Servers? A B C D

4 /Reference: QUESTION 7 A customer is upgrading a Power 595 to a Power 795 and wants to know the estimated power usage of the upgraded system. What is the most comprehensive source for this information? A. Facts and Features B. Workload Estimator C. System Energy Estimator D. Server Specification Sheets Correct Answer: C /Reference: QUESTION 8 A customer is planning 17 LPARs on a Power 795. All LPARs will run AIX 6.1 and use dedicated cores. The other 13 LPARs each have 4 cores and 12 GB RAM What is the minimum number and type(s) of AIX licenses required? A. AIX Enterprise Edition licenses for 96 cores B. AIX Express Edition licenses for 56 cores, and AIX Standard Edition licenses for 40 cores C. AIX Standard Edition licenses for 79 cores, and AIX Enterprise Edition licenses for 17 cores D. AIX Express Edition licenses for 52 cores, AIX Standard Edition licenses for 27 cores, and AIX Enterprise Edition licenses for 17 cores. /Reference: QUESTION 9 Which of the following features is unique to traditional Capacity on Demand servers when compared to Capacity Back Up servers? A. Capacity Upgrade on Demand: the ability to permanently activate inactive cores. B. Processor Sparing: the replacement of cores reporting certain errors with inactive cores. C. On/Off Capacity on Demand: the ability to turn a certain number of cores on for a temporary period. D. Utility Capacity on Demand: the ability to have the system automatically determine how many additional

5 temporary core resources to activate. /Reference: QUESTION 10 A system administrator is installing a third-party monitoring agent on a security-hardened VIO server. The installation of the agent completes without errors, initializes, and network routing is correct, but the monitoring server cannot communicate with the agent installed on the VIO server. What action is necessary to fix this situation? A. Open appropriate ports in the firewalls for the monitoring server. B. Register the monitoring agent in the inetd.conf and run 'startnetsvc'. C. Add the monitoring server to the known_hosts and authorized_keys2 files. D. Ensure that the monitoring agent is installed as a user with the PAdmin role. /Reference: QUESTION 11 An administrator configured IVE in their Power 570 with a multicore scaling (MCS) value of 8. After some time they decided to add more LPARs to the system. To allow more logical ports for the new LPARs, the administrator changed the MCS value in the HMC to 4. When configuring the new LPAR profiles, the administrator does not see the extra ports. Which of the following is the most likely reason? A. Decreasing the MCS value reduces the number of ports available. B. Changing MCS value requires the managed system to undergo a power cycle C. The VIO server must have the "cfgdev" command run to discover the new ports. D. The Host Ethernet configuration (available ports) must be changed to match the IVE configuration. /Reference: QUESTION 12 An administrator has been asked to configure all HMCs to log messages to the company wide syslog server. What is the supported method to accomplish this? A. Use pesh / root access. B. Use chhmc -c syslog command. C. Use rmtlog -event.syslog command. D. Use the Manage Connection Monitoring panel in the HMC. E. Use the Manage Serviceable Event Notification panel in the HMC.

6 /Reference: QUESTION 13 Which of the following statements regarding the Power Hypervisor is true? A. The Hypervisor will consume approximately 0.05% of a core for each LPAR. B. The consumption of the Hypervisor is included in the published rperf figures. C. The Flexible Service Processor (FSP) is automatically allocated to run the Hypervisor. D. The Hypervisor allocates between 5% and 10 % of the number of core entitlements used by the partitions. /Reference: QUESTION 14 Which component is mandatory in LPAR migration? A. WPM - WPAR Manager B. PLM - Partition Load Manager C. ewlm - Enterprise Workload Manager D. RMC - Resource Monitoring and Control /Reference: QUESTION 15 A customer is ordering 10 Power 795 servers. Each system will be configured with 256 cores and 1TB RAM. Two hundred LPARs will be created on each system. Redundant HMCs are a mandatory requirement for the customer. What is the minimum number of HMCs necessary to support the customer requirement? A. 2 B. 4 C. 6 D. 8 /Reference: QUESTION 16 A system administrator must create a mksysb image from one LPAR, and then install many other LPARs with that image.

7 When the administrator attempts to load the mksysb into the second of the virtual optical devices, the following error is displayed: The specified virtual disk is not read-only, and cannot be loaded into multiple devices simultaneously. What command will allow the administrator to resolve this error, and proceed as planned? A. chmod B. chrep C. chdev D. chvopt /Reference: QUESTION 17 A system administrator is adding storage to an AIX 6.1 LPAR that is a virtual SCSI client of a VIO Server LPAR. On the VIO Server, the administrator creates the new virtual target device on the existing virtual SCSI host adapter for the client LPAR, but is presented with a warning that the client LPAR must be rebooted in order to see the new virtual device. Which of the following is the most likely the cause for this warning? A. The number of physical partitions for the new device is too large. B. The maximum queue depth for the vscsi client adapter has been exceeded. C. The memory available for the existing vscsi host adapter has been exhausted. D. The maximum transfer size of the new device is greater than the existing devices. /Reference: QUESTION 18 An administrator has a request to populate a new IBM Power 750 with 50 LPARs. A redundant pair of VIO Servers has been installed and is online. Which option provides the most efficient method for creating new LPARs? A. mksyscfg using the HMC command line B. mklparcfg using the HMC command line C. 'Deploy System Profiles' panel using the HMC web interface D. 'Create Logical Partition' panel using the HMC web interface

8 /Reference: QUESTION 19 A customer is considering consolidating multiple stand-alone systems on to a single Power 795. The systems to be consolidated run AIX 5.3, AIX 6.1 and AIX 7.1. What is the maximum number of cores which may be allocated to LPARs at each level of AIX? A. AIX AIX AIX B. AIX AIX AIX C. AIX AIX AIX D. AIX AIX AIX /Reference: QUESTION 20 An architect is preparing to deploy a three-tier application on a new Power 795 system that has 64 activated cores. The solution is licensed by the number of cores used by the application server LPARs. The same number of cores may be used, without charge, for the database manager. There is no limitation on the number of cores used by the web server LPARs. The company has purchased a license allowing the use 32 cores of the Power 795 system for the application server LPARs. Which of the following Shared Processor Pool configurations supports these requirements? A. Change SharedPool01 to set Reserved Processing Units = 32 and Maximum Processing Units = 64.Change SharedPool02 to set Reserved Processing Units = 0 and Maximum Processing Units = 64 B. Change SharedPool01 to set Reserved Processing Units = 0 and Maximum Processing Units = 32.Change SharedPool02 to set Reserved Processing Units = 0 and Maximum Processing Units = 32. C. Change SharedPool01 to set Reserved Processing Units = 32 and Maximum Processing Units = 32.Change SharedPool02 to set Reserved Processing Units = 32 and Maximum Processing Units = 64 D. Change SharedPool01 to set Reserved Processing Units = 32 and Maximum Processing Units = 32.Change SharedPool02 to set Reserved Processing Units = 0 and Maximum Processing Units = 32. /Reference: QUESTION 21 A customer plans to use Live Partition Mobility (LPM) to move an LPAR running AIX 7 from a Power 770 to a POWER6 570.In which CPU preferred compatibility mode should the LPAR be before migration begins? A. Auto B. POWER6 C. Default D. POWER6 enhanced

9 /Reference: QUESTION 22 A client has been using Live Partition Mobility to move partitions between existing POWER6 frames. They have recently deployed a number of POWER7 frames managed by new HMCs and would like to take advantage of Remote Live Partition Mobility to move partitions between the frames. After verifying network connectivity between HMCs, what is the next step to enable Remote Live Partition Mobility? A. Configure an RMC connection between them B. Configure SSH authentication between them C. Import the Kerberos host principals for each HMC to authenticate using a KDC D. Test RMC connections from the source HMC to the destination mover service partition /Reference: QUESTION 23 Customer wants to consolidate POWER4, POWER5 and POWER6 systems on to a POWER7 server. What resource will indicate an appropriate POWER7 server? A. Power Systems Performance Report B. Power System Consolidation Handbook C. Power Systems Hardware Information Center D. Power Systems Hardware Server Specification sheet /Reference: QUESTION 24 A customer is concerned with software licensing costs and maximizing throughput per core on the system. Which of the following system configurations supports these requirements? A. A Power 770 configured for MaxCore Mode B. A Power 780 configured for MaxCore Mode C. A Power 770 configured for TurboCore Mode D. A Power 780 configured for TurboCore Mode /Reference: QUESTION 25

10 A customer is ordering new Power 780 and 795 hardware. Within their data center, existing HMCs already manage POWER5 and POWER6 deployments. These existing HMCs are either 7310-CR2, 7042-CR4 or CR5 models. What must be considered with regard to the management of POWER7 hardware? A. Only their 7042-CR5 HMCs can run the minimum required Version 7 Revision 720 HMC code. B. All their existing HMCs will need to be upgraded to at least Version 7 Revision 720 HMC code. C. Only their 7042-CR4 and 7042-CR5 can run the minimum required Version 7 Revision 720 HMC code. D CR6 is the only supported rack-mounted HMC which can run Version 7 Revision 720 and later HMC code. Correct Answer: C /Reference: QUESTION 26 How can a system administrator determine if an existing LPAR is correctly configured for Live Partition Mobility? A. Use the "migrlpar" command on the HMC with "-o v" option. B. Use the "lslparmig" command on the HMC with the "-r lpar -t" option. C. Activate an LPAR on the target system using the same LUNs and network. D. Create a sysplan on the source system and deploy it on the target system. /Reference: QUESTION 27 Which of the following is the correct method to rename hdisk11 to testdisk1? A. rendev -l hdisk11 -n testdisk1 B. mv /dev/hdisk11 /dev/testdisk1 C. chdsk -dev hdisk11 -id testdisk1 D. chdev -l hdisk11 -a name=testdisk1 /Reference: QUESTION 28 An administrator has configured a system to provide resilient networking through the use of SEA failover. The administrator wants to know if the SEA for one VIO server, ent10, is the active adapter. Which of the following commands could the administrator use to determine the status of ent10? A. entstat -net ent10 B. lsmap -net -dev ent10 C. seastat -liststat ent10

11 D. netstat -cdlistats ent10 Correct Answer: C /Reference: QUESTION 29 Which of the following supports Active Memory Sharing (AMS)? A. POWER6, AIX 7.1 and PowerVM Basic Edition B. POWER7, AIX 7.1 and PowerVM Express Edition C. POWER7, AIX 6.1 and PowerVM Standard Edition D. POWER6, AIX 6.1 and PowerVM Enterprise Edition /Reference: QUESTION 30 Where can Power Saving mode on a Power 770 be enabled? A. HMC and ASMI B. ASMI and Operator Panel C. Intelligent PDU and HMC D. Operator Panel and Operating System. /Reference: QUESTION 31 An administrator must add support for a new VLAN to a VIO Server that currently services multiple VLANs on a single SEA. No additional network ports are available. How can this be achieved without interrupting the SEA? A. Use DLPAR to add a new virtual ethernet adapter to the VIO Server. Use the chdev command to add the new virtual adapter to the SEA. B. Use DLPAR to add a new virtual ethernet adapter to the VIO Server. Use the chgsea command to add the new virtual adapter to the SEA. C. Use DLPAR to enable 802.1Q and add the VLAN to the virtual ethernet adapter. Use the chdev command to add the new virtual adapter to the SEA. D. Use DLPAR to enable 802.1Q and add the VLAN to the virtual ethernet adapter. Use the chgsea command to add the new virtual adapter to the SEA.

12 /Reference: QUESTION 32 A system administrator has a Power 770 with 12 cores. The following LPARs already exist: LPAR1-9 dedicated cores LPAR2-1 virtual processors with an entitled capacity of 0.2 LPAR3-1 virtual processors with an entitled capacity of 0.8 The administrator wants to create a fourth LPAR. What is the maximum entitled capacity and virtual processors which can be allocated? A. 1 virtual processor with an entitled capacity of 2.0 B. 2 virtual processors with an entitled capacity of 2.0 C. 1 virtual processor with an entitled capacity of D. 20 virtual processors with an entitled capacity of 2.0. E. 12 virtual processors with an entitled capacity of 2.0. F. 20 virtual processors with an entitled capacity of /Reference: QUESTION 33 What is a prerequisite for Live Partition Mobility? A. Source and destination hardware must be the same model/type. B. All network and storage resources of the LPAR must be virtual. C. Only a single shared-processor pool may exist on the source and destination hardware. D. An LPAR with the same name must be present on the destination server prior to the move. /Reference: QUESTION 34 An administrator installed a new HMC and connected several managed systems to it. According to company policy the open network, used for user access to HMC, should be firewalled. Which service must be permitted through the firewall to enable DLPAR operations? A. SSH B. DNS C. RMC D. LDAP Correct Answer: C

13 /Reference: QUESTION 35 A customer uses NIM for OS and software deployment on 64 LPARs divided into three groups: development, test and production. What is the quickest way to install fixes on the test servers only? A. Create an install script that lists only the test serversdefine this as a 'script' NIM resourceperform a 'maint' operation using the created resource. B. Create a new lpp_source containing the required fixescreate a mac_group NIM resource containing the test machinesperform an 'update_all' operation across the created group. C. Create a new lpp_source containing the required fixescreate a mac_group NIM resource and populate with only the test serversperform a 'maint' operation across the created group. D. Update corresponding lpp and spot resources on the NIM mastercreate a res_group NIM resource and populate with only the test serversperform an 'update_all' operation across that created group. /Reference: QUESTION 36 A VIO Server is installed on the mirrored disks hdisk0 and hdisk1. During an update the VIO Server crashed. After rebooting, the administrator detects that hdisk1 is broken. The administrator decided to restore a previously made backup from the NIM server, and removed the damaged hdisk1.what step is required to restore the VIO Server on only hdisk0 from the NIM Server? A. The VIO Server must be installed with a modified image.data resource. B. Run the nim command on the mksysb resource using the mirror=no option. C. The VIO Server must be installed with a modified bosinst.data resource. D. During the startup procedure the admin has to set the 'Shrink File Systems' option to 'yes'. /Reference: QUESTION 37 An administrator updated tunable virtual memory parameters using vmo -p. When the system was rebooted the tuning was lost. Which of the following is the most likely reason? A. The /etc/objrepos/nextboot file was removed. B. Only non-restricted tunables can be changed permanently. C. The bosboot command must be run to make changes permanent. D. The tunables entry is missing or is incorrectly defined in the /etc/inittab file. /Reference:

14 QUESTION 38 An administrator created a JFS2 snapshot and mounted it using the following commands: Snapshot-o snapfrom=/home/adminfh-o size=1g Mount-o snapshot /dev/fslv16 /backup Backup was started using a script. After an hour the administrator lists the backup directory and received the following error message: Is: /backup: There is an input or output error. What is the most likely reason? A. The snapshot ran out of space and is now invalid. B. Backup directories are locked during snapshot operations. C. The incorrect command was used to list the backup directory. D. Filesystem write operations were improperly suspended prior to taking the snapshot. /Reference: QUESTION 39 SMT4 (Simultaneous Multithreading using four threads) is a new feature in Power 795 hardware. Which minimum releases of AIX and IBM i can exploit this feature? A. AIX 7.1 and IBM i 7.1 B. AIX 7.1 and IBM i C. AIX 6.1 TL6 and IBM i D. AIX 6.1 TL6 and IBM i Correct Answer: C /Reference: QUESTION 40 A company wide time server has been established and the AIX administrator has been asked to configure all HMCs to connect to this time server. Which of the following statements is correct? A. Time server configuration can be changed using vi /etc/ntp.conf B. Time server configuration can be changed using chhmc -c xntp command. C. Time server configuration requires a pesh password obtained from IBM Service. D. Time server configuration requires Systems Director with the VMControl plugin.

15 /Reference: QUESTION 41 The root user in an LPAR has the ability to remotely execute CLI commands on an HMC without being prompted for a password. That capability must be removed in order to comply with security rules. Which of the following commands describes the supported method to delete unneeded key from the authorized_keys2 file? A. delkey B. chkeys C. chhmcuser D. mkauthkeys E. rmauthkeys /Reference: QUESTION 42 What will be the operational impact of hosting a Power 795 at an altitude in excess of 2134 meters (7000 feet)? A. Additional humidifiers will be required; the altitude will result in a 2% decrease in relative humidity. B. Additional site inspection by the Installation Planning Representative is required before the system ships. C. Additional electrical power is used by the hardware; the altitude will result in a 3% increase in Kw rating. D. Additional cooling will be required; the maximum operating temperature decreases 2 degrees C per 305 meters (1000 feet). /Reference: QUESTION 43 A customer application deployment consists of two LPARs hosted on the same physical system; one hosting a back-end database, the other hosting a customer-facing web application. Since the hardware was ordered, the application design was updated to list a requirement of a dedicated network link between the two LPARs. Which option would meet the networking requirements while minimizing expenses? A. Purchase two new Ethernet adapters, assign one to each LPAR and connect them with a cross-over cable. B. Purchase a second IVE adapter and assign a logical port to each LPAR. Connect the ports using a standard Ethernet cable. C. Install VIO server and make a Shared Ethernet Adapter, assign this to both LPARs. No new physical cabling will be required. D. Create two Virtual Ethernet adapters within a dedicated VLAN, assign one to each LPAR. No new physical cabling will be required.

16 /Reference: QUESTION 44 A customer is trying to configure a Shared Ethernet Adapter on a Logical Host Ethernet port using the following command: mkvdev -sea ent0 -vadapter ent2 -default ent2 -defaultid 1 The following response is received: error initializing a device into the kernel Which of the following is the most likely cause for this problem? A. The VIOS partition needs more memory B. SEA cannot use the default VLAN id of 1 C. The SEA can only be created on a physical network adapter D. Promiscuous mode on the virtual Ethernet adapter must set to "on" E. On VIO server's profile the virtual adapter has the "Access External Networks" box checked. /Reference: QUESTION 45 An administrator is trying to configure NPIV on a new VIO Server partition. When running the Isnports command the following is displayed:

17 Which of the following statements correctly summarizes this situation? A. The adapter is not NPIV compliant. B. The adapter is not connected to an NPIV-capable switch. C. The adapter is not set to an NPIV-capable class of service. D. The adapter firmware level is not at an NPIV-supported version. /Reference: QUESTION 46 A customer implemented a PowerHA System Mirror cluster for their database. The cluster is used simultaneously by many clients during work hours. For the non-ip heartbeat network, they decided to use the same LUN as for the data files. Which problem can arise during normal use of the cluster? A. High application access can cause the deadman switch to be triggered. B. The cluster will not start, because it needs a separate LUN for non-ip heartbeat. C. A reservation conflict can arise between the heartbeat function and normal data access. D. A lock from one node in the cluster can prevent other nodes reporting heartbeat functions.

18 /Reference: QUESTION 47 A customer performed a mksysb backup of VIO client LPAR to a SAN-attached tape drive. How can this mksysb be restored back to an LPAR? A. Restore using nimadm from the SAN-attached tape. B. Restore the mksysb to the partition using TSM from the SAN-attached tape. C. Create a mksysb NIM resource using the tape drive as source and restore using that resource. D. Copy the mksysb to a file on a NIM server and restore using a resource created from that file. /Reference: QUESTION 48 Which of the following is required by Live Application Mobility? A. WPAR Manager (Workload Partition Manager) B. The same Hypervisor level on source and destination C. PowerVM Enterprise Edition on source and destination D. Source and target WPARs with identical configurations /Reference: QUESTION 49 An administrator is evaluating consolidating Power servers running relational database management systems (RDBMS). After reviewing the collection of nmon andtopas data for the candidate systems, the administrator is concerned by the total amount of RAM that the consolidation seems to require, based on the RAM allocated to each candidate system. The administrator reviews the memory sections of thetopas data to see if reducing total RAM required is possible. None of the systems indicate any activity to the paging spaces. Which of the following metrics would help the administrator determine the minimum RAM required to host the RDBMS partitions in the consolidated environment? A. Free pages B. Persistent pages C. Computational pages D. Real pages-free pages E. Computational pages + persistent pages Correct Answer: C

19 /Reference: QUESTION 50 A system administrator wants to use topasrec to collect processor performance data for all AIX LPARs on one Power 795. Seven days of data will be collected, with one data file created per day. Which of the following recording approaches supports the requirement? A. Continuous CEC monitoring on one LPAR B. Persistent CEC monitoring on one LPAR C. Continuous local monitoring on each LPAR D. Persistent local monitoring on each LPAR /Reference: QUESTION 51 Which of these HMC commands will display fixes which have been applied to the HMC? A. Ishmc-f B. Ishmc-F C. Ishmc-V D. Ishmc-I Correct Answer: C /Reference: QUESTION 52 A system administrator is updating the VIO Server levels in a frame supported by a dual VIO Server pair. After applying the latest fixpack to the first VIO Server and rebooting the administrator notices some of the VIO Server clients have failed paths to the storage as reported by Ispath After confirming the upgraded VIO Server is presenting all disks without any errors what is the most likely cause of the failed paths? A. The vscsi_priority is set to 0. B. The hcheckjnterval is set to 0. C. The two VIO Servers are running mixed levels. D. Disk reservations were added during the upgrade. /Reference:

20

KillTest *KIJGT 3WCNKV[ $GVVGT 5GTXKEG Q&A NZZV ]]] QORRZKYZ IUS =K ULLKX LXKK [VJGZK YKX\OIK LUX UTK _KGX

KillTest *KIJGT 3WCNKV[ $GVVGT 5GTXKEG Q&A NZZV ]]] QORRZKYZ IUS =K ULLKX LXKK [VJGZK YKX\OIK LUX UTK _KGX KillTest Q&A Exam : 000-108 Title : Enterprise Technical Support for AIX and Linux -v2 Version : Demo 1 / 7 1.Which power reduction technology requires a software component in order to be activated? A.

More information

Vendor: IBM. Exam Code: C Exam Name: Enterprise Technical Support for AIX and Linux -v2. Version: Demo

Vendor: IBM. Exam Code: C Exam Name: Enterprise Technical Support for AIX and Linux -v2. Version: Demo Vendor: IBM Exam Code: C4040-108 Exam Name: Enterprise Technical Support for AIX and Linux -v2 Version: Demo QUESTION 1 Which power reduction technology requires a software component in order to be activated?

More information

Testinexam Number: Passing Score: 800 Time Limit: 120 min File Version: 1.0

Testinexam Number: Passing Score: 800 Time Limit: 120 min File Version: 1.0 Testinexam 000-272 Number: 000-272 Passing Score: 800 Time Limit: 120 min File Version: 1.0 http://www.gratisexam.com/ www.test-inexam.com Exam A QUESTION 1 Which power reduction technology requires a

More information

IBM EXAM QUESTIONS & ANSWERS

IBM EXAM QUESTIONS & ANSWERS IBM 000-108 EXAM QUESTIONS & ANSWERS Number: 000-108 Passing Score: 800 Time Limit: 120 min File Version: 46.6 http://www.gratisexam.com/ IBM 000-108 EXAM QUESTIONS & ANSWERS Exam Name: Enterprise Technical

More information

IBM Virtualization Technical Support for AIX and Linux - v2.

IBM Virtualization Technical Support for AIX and Linux - v2. IBM 000-109 Virtualization Technical Support for AIX and Linux - v2 http://killexams.com/exam-detail/000-109 QUESTION: 170 A Power Systems server has two HMCs connected to its Flexible Service Processor

More information

C IBM. Virtualization Technical Support for AIX and Linux V2

C IBM. Virtualization Technical Support for AIX and Linux V2 C4040-109 Dumps C4040-109 Braindumps C4040-109 Real Questions C4040-109 Practice Test C4040-109 dumps free IBM C4040-109 Virtualization Technical Support for AIX and Linux V2 http://killexams.com/pass4sure/exam-detail/c4040-109

More information

Virtualization Technical Support for AIX and Linux - v2

Virtualization Technical Support for AIX and Linux - v2 IBM 000-109 Virtualization Technical Support for AIX and Linux - v2 Version: 5.0 Topic 1, Volume A QUESTION NO: 1 An administrator is attempting to configure a new deployment of 56 POWER7 Blades across

More information

IBM Enterprise Technical Support for AIX and Linux -v2. Download Full Version :

IBM Enterprise Technical Support for AIX and Linux -v2. Download Full Version : IBM 000-108 Enterprise Technical Support for AIX and Linux -v2 Download Full Version : http://killexams.com/pass4sure/exam-detail/000-108 QUESTION: 117 An administrator is preparing fibre-channel attached

More information

IBM EXAM QUESTIONS & ANSWERS

IBM EXAM QUESTIONS & ANSWERS IBM 000-106 EXAM QUESTIONS & ANSWERS Number: 000-106 Passing Score: 800 Time Limit: 120 min File Version: 38.8 http://www.gratisexam.com/ IBM 000-106 EXAM QUESTIONS & ANSWERS Exam Name: Power Systems with

More information

IBM p5 and pseries Enterprise Technical Support AIX 5L V5.3. Download Full Version :

IBM p5 and pseries Enterprise Technical Support AIX 5L V5.3. Download Full Version : IBM 000-180 p5 and pseries Enterprise Technical Support AIX 5L V5.3 Download Full Version : https://killexams.com/pass4sure/exam-detail/000-180 A. The LPAR Configuration backup is corrupt B. The LPAR Configuration

More information

Live Partition Mobility Update

Live Partition Mobility Update Power Systems ATS Live Partition Mobility Update Ron Barker Power Advanced Technical Sales Support Dallas, TX Agenda Why you should be planning for partition mobility What are your options? Which is best

More information

Application and Partition Mobility

Application and Partition Mobility IBM System p Application and Mobility Francis COUGARD IBM Products and Solutions Support Center Montpellier Copyright IBM Corporation 2009 Index Application and Mobility Presentation Videocharger and DB2

More information

PASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year

PASS4TEST. IT Certification Guaranteed, The Easy Way!   We offer free update service for one year PASS4TEST \ http://www.pass4test.com We offer free update service for one year Exam : C9010-022 Title : IBM AIX Administration V1 Vendor : IBM Version : DEMO Get Latest & Valid C9010-022 Exam's Question

More information

Power Systems with POWER7 and AIX Technical Sales

Power Systems with POWER7 and AIX Technical Sales Power Systems with POWER7 and AIX Technical Sales Number: 000-107 Passing Score: 800 Time Limit: 120 min File Version: 26.6 http://www.gratisexam.com/ IBM 000-107 EXAM QUESTIONS & ANSWERS Exam Name: Power

More information

Live Partition Mobility

Live Partition Mobility Live Partition Mobility Jaqui Lynch lynchj@forsythe.com Presentation at: http://www.circle4.com/forsythe/lpm2014.pdf 1 1 Why Live Partition Mobility? LPM LIVE PARTITION MOBILITY Uses Server Consolidation

More information

IBM p5 Virtualization Technical Support AIX 5L V5.3. Download Full Version :

IBM p5 Virtualization Technical Support AIX 5L V5.3. Download Full Version : IBM 000-062 p5 Virtualization Technical Support AIX 5L V5.3 Download Full Version : https://killexams.com/pass4sure/exam-detail/000-062 A. Virtual Ethernet B. Micro-Partitioning C. Virtual I/O Server D.

More information

C exam. Number: C Passing Score: 800 Time Limit: 120 min IBM C IBM AIX Administration V1.

C exam. Number: C Passing Score: 800 Time Limit: 120 min IBM C IBM AIX Administration V1. C9010-022.exam Number: C9010-022 Passing Score: 800 Time Limit: 120 min IBM C9010-022 IBM AIX Administration V1 Exam A QUESTION 1 A customer has a virtualized system using Virtual I/O Server with multiple

More information

IBM Exam A Virtualization Technical Support for AIX and Linux Version: 6.0 [ Total Questions: 93 ]

IBM Exam A Virtualization Technical Support for AIX and Linux Version: 6.0 [ Total Questions: 93 ] s@lm@n IBM Exam A4040-101 Virtualization Technical Support for AIX and Linux Version: 6.0 [ Total Questions: 93 ] IBM A4040-101 : Practice Test Question No : 1 Which of the following IOS commands displays

More information

BMC Capacity Optimization Extended Edition AIX Enhancements

BMC Capacity Optimization Extended Edition AIX Enhancements BMC Capacity Optimization Extended Edition 9.5.1 AIX Enhancements Support for AIX Active Memory Expansion (AME) mode Metrics displayed in BCO AIX PowerVM view for CPU and Memory Allocation Frame name,

More information

IBM Systems Director VMControl

IBM Systems Director VMControl IBM Systems Director VMControl Glen Corneau Copyright IBM Corporation 2011 Materials may not be reproduced in whole or in part without the prior written permission of IBM. 5.3 Agenda > VMControl V2.3.1

More information

Power Systems with POWER8 Scale-out Technical Sales Skills V1

Power Systems with POWER8 Scale-out Technical Sales Skills V1 Power Systems with POWER8 Scale-out Technical Sales Skills V1 1. An ISV develops Linux based applications in their heterogeneous environment consisting of both IBM Power Systems and x86 servers. They are

More information

IBM SYSTEM POWER7. PowerVM. Jan Kristian Nielsen Erik Rex IBM Corporation

IBM SYSTEM POWER7. PowerVM. Jan Kristian Nielsen Erik Rex IBM Corporation IBM SYSTEM POWER7 PowerVM Jan Kristian Nielsen jankn@dk.ibm.com - +45 28803310 Erik Rex Rex@dk.ibm.com - +45 28803326 PowerVM: Virtualization Without Limits Reduces IT infrastructure costs Improves service

More information

Virtualization Benefits IBM Corporation

Virtualization Benefits IBM Corporation Virtualization Benefits 1 Virtualization Benefits CPU Utilization 100 90 80 70 60 50 40 30 20 10 0 8:00 10:00 12:00 2:00 4:00 Time Purchased Peak Average Increase Utilization Non-virtualized servers often

More information

Experiences with VIOS support for IBM i

Experiences with VIOS support for IBM i Experiences with VIOS support for IBM i Pete Stephen, Power Systems / AIX Architect Sirius Computer Solutions Pete.Stephen@siriuscom.com Agenda VIO overview Virtualization Trends. PowerVM and how do I

More information

Exam Name: Enterprise Technical Support for AIX and

Exam Name: Enterprise Technical Support for AIX and Exam Code: 000-100 Exam Name: Enterprise Technical Support for AIX and Linux Vendor: IBM Version: DEMO Part: A 1: After configuring a Shared Ethernet Adapter (SEA) on a Virtual I/O server, one client partition

More information

Exam Name: Virtualization Technical Support for AIX and

Exam Name: Virtualization Technical Support for AIX and Exam Code: 000-101 Exam Name: Virtualization Technical Support for AIX and Linux Vendor: IBM Version: DEMO Part: A 1: A customer has a Power 570 system with the following configuration: 2 active CPUs 16

More information

Actual4Test. Actual4test - actual test exam dumps-pass for IT exams

Actual4Test.   Actual4test - actual test exam dumps-pass for IT exams Actual4Test http://www.actual4test.com Actual4test - actual test exam dumps-pass for IT exams Exam : 000-180 Title : P5 and pseries Enterprise Technical Support Aix 5L V5.3 Vendors : IBM Version : DEMO

More information

Q&As. AIX 7 Administration. Pass IBM Exam with 100% Guarantee. Free Download Real Questions & Answers PDF and VCE file from:

Q&As. AIX 7 Administration. Pass IBM Exam with 100% Guarantee. Free Download Real Questions & Answers PDF and VCE file from: 000-221 Q&As AIX 7 Administration Pass IBM 000-221 Exam with 100% Guarantee Free Download Real Questions & Answers PDF and VCE file from: 100% Passing Guarantee 100% Money Back Assurance Following Questions

More information

Planning for Virtualization on System P

Planning for Virtualization on System P Planning for Virtualization on System P Jaqui Lynch Systems Architect Mainline Information Systems Jaqui.lynch@mainline.com com http://www.circle4.com/papers/powervm-performance-may09.pdf http://mainline.com/knowledgecenter

More information

February 5, 2008 Virtualization Trends On IBM s System P Unraveling The Benefits In IBM s PowerVM

February 5, 2008 Virtualization Trends On IBM s System P Unraveling The Benefits In IBM s PowerVM Virtualization Trends On IBM s System P Unraveling The Benefits In IBM s PowerVM by Brad Day with Simon Yates and Rachel Batiancila EXECUTIVE SUMMARY IBM s PowerVM (formerly Advanced POWER Virtualization)

More information

System i and System p. Creating a virtual computing environment

System i and System p. Creating a virtual computing environment System i and System p Creating a virtual computing environment System i and System p Creating a virtual computing environment Note Before using this information and the product it supports, read the information

More information

The Power of PowerVM Power Systems Virtualization. Eyal Rubinstein

The Power of PowerVM Power Systems Virtualization. Eyal Rubinstein The Power of PowerVM Power Systems Virtualization Eyal Rubinstein deyal@il.ibm.com The Power Equation: Power = i + p System i i515 i525 i550 i570 i595 IBM BladeCenter BladeCenter JS12/22/23 Express BladeCenter

More information

PowerVM simplification enhancements. PowerVM simplification enhancements. PowerVM infrastructure overview

PowerVM simplification enhancements. PowerVM simplification enhancements. PowerVM infrastructure overview PowerVM simplification enhancements PowerVM infrastructure overview IBM PowerVM is the virtualization solution that enables workload consolidation for AIX, IBM i, and Linux environments on IBM Power Systems

More information

System p. Partitioning with the Integrated Virtualization Manager

System p. Partitioning with the Integrated Virtualization Manager System p Partitioning with the Integrated Virtualization Manager System p Partitioning with the Integrated Virtualization Manager Note Before using this information and the product it supports, read the

More information

HMC ENHANCED GUI QUICK START GUIDE 1.0 Classic GUI to Enhanced GUI Mappings and Enhanced GUI Improvements

HMC ENHANCED GUI QUICK START GUIDE 1.0 Classic GUI to Enhanced GUI Mappings and Enhanced GUI Improvements HMC ENHANCED GUI QUICK START GUIDE 1.0 Classic GUI to Enhanced GUI Mappings and Enhanced GUI Improvements August 2017 Table of Contents Contributing Author: Karyn Corneli Co-Author: Jacobo Vargas Introduction...

More information

IBM EXAM - C AIX 7 Administration. Buy Full Product.

IBM EXAM - C AIX 7 Administration. Buy Full Product. IBM EXAM - C4040-221 AIX 7 Administration Buy Full Product http://www.examskey.com/c4040-221.html Examskey IBM C4040-221 exam demo product is here for you to test the quality of the product. This IBM C4040-221

More information

IBM Power Systems with POWER7 and AIX Technical Sales Skills - v1.

IBM Power Systems with POWER7 and AIX Technical Sales Skills - v1. IBM 000-107 Power Systems with POWER7 and AIX Technical Sales Skills - v1 http://killexams.com/exam-detail/000-107 A customer has applications that run on POWER4 servers that require AIX 5.2. The customer

More information

PASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year

PASS4TEST. IT Certification Guaranteed, The Easy Way!   We offer free update service for one year PASS4TEST \ http://www.pass4test.com We offer free update service for one year Exam : 000-122 Title : Power Systems with POWER7 Common Sales Skills -v2 Vendor : IBM Version : DEMO 1 / 4 Get Latest & Valid

More information

VIOS FP25_SP05

VIOS FP25_SP05 VIOS 2.2.1.7 FP25_SP05 Contributed by Michael Felt Package information PACKAGE: Update Release 2.2.1.7 IOSLEVEL: 2.2.1.7 VIOS level is NIM Master level must be equal to or higher than Service Pack 05 for

More information

Advanced Virtual I/O Server Configurations. César Diniz Maciel Consulting IT Specialist IBM US

Advanced Virtual I/O Server Configurations. César Diniz Maciel Consulting IT Specialist IBM US Advanced Virtual I/O Server Configurations César Diniz Maciel Consulting IT Specialist IBM US Agenda Virtual Optical Devices, Virtual Optical Media, File-backed Devices Shared Ethernet Adapter (SEA) Failover

More information

Vendor: IBM. Exam Code: C Exam Name: Power Systems with POWER8 Scale-out Technical Sales Skills V1. Version: Demo

Vendor: IBM. Exam Code: C Exam Name: Power Systems with POWER8 Scale-out Technical Sales Skills V1. Version: Demo Vendor: IBM Exam Code: C9010-251 Exam Name: Power Systems with POWER8 Scale-out Technical Sales Skills V1 Version: Demo QUESTION 1 What is a characteristic of virtualizing workloads? A. Processors are

More information

Mechanic v. Surgeon (photos from istockphoto.com)

Mechanic v. Surgeon (photos from istockphoto.com) 0 Mechanic v. Surgeon (photos from istockphoto.com) 1 2007: AIX Kernel hotpatch support available with AIX 6.1 2008: Ksplice Linux hotpatch support (based on MIT student s master s thesis) Stops all running

More information

System i and System p. Managing the Integrated Virtualization Manager

System i and System p. Managing the Integrated Virtualization Manager System i and System p Managing the Integrated Virtualization Manager System i and System p Managing the Integrated Virtualization Manager Note Before using this information and the product it supports,

More information

Power your planet. Optimizing the Enterprise Data Center POWER7 Powers a Smarter Infrastructure

Power your planet. Optimizing the Enterprise Data Center POWER7 Powers a Smarter Infrastructure Power your planet. Optimizing the Enterprise Data Center POWER7 Powers a Smarter Infrastructure Enoch Lau Field Technical Sales Specialist, Power Systems Systems & Technology Group Power your planet. Smarter

More information

Planning and Sizing Virtualization

Planning and Sizing Virtualization Planning and Sizing Virtualization Jaqui Lynch Architect, Systems Engineer Mainline Information Systems http://www.circle4.com/papers/cmgvirt.pdf 1 What is Virtualization? Being able to dynamically move

More information

Oracle Database 11g R2 Oracle Database 11g R2 RAC on IBM AIX Tips and Considerations

Oracle Database 11g R2 Oracle Database 11g R2 RAC on IBM AIX Tips and Considerations Oracle Database 11g R2 Oracle Database 11g R2 RAC on IBM AIX Tips and Considerations Ravisankar Shanmugam IBM Oracle International Competency Center Nov 27, 2012 1 Table of contents Abstract... 3 Introduction...

More information

IBM C IBM AIX Administration V1. Download Full Version :

IBM C IBM AIX Administration V1. Download Full Version : IBM C9010-022 IBM AIX Administration V1 Download Full Version : http://killexams.com/pass4sure/exam-detail/c9010-022 QUESTION: 251 Consider the following screen capture. The administrator needs to add

More information

C IBM. Power Systems Enterprise Technical Support for AIX and Linux -v2

C IBM. Power Systems Enterprise Technical Support for AIX and Linux -v2 IBM C4040-108 Power Systems Enterprise Technical Support for AIX and Linux -v2 Download Full Version : https://killexams.com/pass4sure/exam-detail/c4040-108 A. Ishmc-f B. Ishmc-F C. Ishmc-V D. Ishmc-I

More information

pseries Partitioning AIX 101 Jaqui Lynch USERblue 2004

pseries Partitioning AIX 101 Jaqui Lynch USERblue 2004 pseries Partitioning AIX 0 Jaqui Lynch USERblue 2004 Jaqui.lynch@mainline.com http://www.circle4.com/papers/ubaixpart04.pdf Agenda Partitioning Concepts Hardware Software Planning Hints and Tips References

More information

IBM Power 520 and Power 550 support the AIX, IBM i, and Linux operating systems

IBM Power 520 and Power 550 support the AIX, IBM i, and Linux operating systems Announcement ZG08-0790, dated October 7, 2008 IBM Power 520 and Power 550 support the AIX, IBM i, and Linux operating systems Table of contents 2 Key prerequisites 30 Technical information 2 Planned availability

More information

Exam Name: Assessment: Power Systems with POWER7 Common Sales Skills -v2

Exam Name: Assessment: Power Systems with POWER7 Common Sales Skills -v2 Vendor: IBM Exam Code: A4040-122 Exam Name: Assessment: Power Systems with POWER7 Common Sales Skills -v2 Version: Demo Topic 1, Volume A Question No : 1 - (Topic 1) A customer needs 2 Power Systems servers,

More information

iseries Tech Talk Linux on iseries Technical Update 2004

iseries Tech Talk Linux on iseries Technical Update 2004 iseries Tech Talk Linux on iseries Technical Update 2004 Erwin Earley IBM Rochester Linux Center of Competency rchlinux@us.ibm.com Agenda Enhancements to the Linux experience introduced with i5 New i5/os

More information

Vendor: IBM. Exam Code: C Exam Name: Power Systems with POWER7 and IBM i Technical Sales Skills -v2. Version: Demo

Vendor: IBM. Exam Code: C Exam Name: Power Systems with POWER7 and IBM i Technical Sales Skills -v2. Version: Demo Vendor: IBM Exam Code: C4040-226 Exam Name: Power Systems with POWER7 and IBM i Technical Sales Skills -v2 Version: Demo Question No : 1 A customer with a POWERS 520 running IBM i is debating consolidating

More information

Integrated Virtualization Manager. ESCALA Power7 REFERENCE 86 A1 41FF 08

Integrated Virtualization Manager. ESCALA Power7 REFERENCE 86 A1 41FF 08 Integrated Virtualization Manager ESCALA Power7 REFERENCE 86 A1 41FF 08 ESCALA Models Reference The ESCALA Power7 publications concern the following models: Bull Escala E1-700 / E3-700 Bull Escala E1-705

More information

Power Systems SAN Multipath Configuration Using NPIV v1.2

Power Systems SAN Multipath Configuration Using NPIV v1.2 v1.2 Bejoy C Alias IBM India Software Lab Revision History Date of this revision: 27-Jan-2011 Date of next revision : TBD Revision Number Revision Date Summary of Changes Changes marked V1.0 23-Sep-2010

More information

IBM PureFlex Technical

IBM PureFlex Technical IBM PureFlex Technical Number: 000-783 Passing Score: 660 Time Limit: 90 min File Version: 1.0 http://www.gratisexam.com/ Exam A QUESTION 1 Which of the following virtualization products is required to

More information

IBM Exam C IBM AIX Administration V1 Version: 7.0 [ Total Questions: 258 ]

IBM Exam C IBM AIX Administration V1 Version: 7.0 [ Total Questions: 258 ] s@lm@n IBM Exam C9010-022 IBM AIX Administration V1 Version: 7.0 [ Total Questions: 258 ] IBM C9010-022 : Practice Test Topic break down Topic No. of Questions Topic 1: Volume A 49 Topic 2: Volume B 50

More information

Installation and User's Guide

Installation and User's Guide IBM Systems Director VMControl Installation and User's Guide Version 2 Release 3 IBM Systems Director VMControl Installation and User's Guide Version 2 Release 3 ii IBM Systems Director VMControl: Installation

More information

IBM - C AIX 7 Administration Version: 7.1

IBM - C AIX 7 Administration Version: 7.1 IBM - C4040-221 AIX 7 Administration Version: 7.1 1 Topic 1, Volume A QUESTION: 1 The following information has been reported in an AIX error log: How can the administrator prevent the error from reoccurring?

More information

Power Systems. Overview of SDMC

Power Systems. Overview of SDMC Power Systems Overview of SDMC Power Systems Overview of SDMC te Before using this information and the product it supports, read the information in tices on page 33. This edition applies to IBM Systems

More information

C Number: C Passing Score: 800 Time Limit: 120 min File Version: 5.0. IBM C Questions & Answers

C Number: C Passing Score: 800 Time Limit: 120 min File Version: 5.0. IBM C Questions & Answers C4040-251 Number: C4040-251 Passing Score: 800 Time Limit: 120 min File Version: 5.0 http://www.gratisexam.com/ IBM C4040-251 Questions & Answers Power Systems with POWER8 Scale-out Technical Sales Skills

More information

IBM PowerVM. Virtualization without limits. Highlights. IBM Systems and Technology Data Sheet

IBM PowerVM. Virtualization without limits. Highlights. IBM Systems and Technology Data Sheet IBM PowerVM Virtualization without limits Highlights Deliver services with superior economics by consolidating virtualized workloads Deliver services faster by automating deployment of virtual machines

More information

April Power Systems Roadshow

April Power Systems Roadshow April 2008 Power Systems Roadshow The IBM Systems family BladeCenter Simplify Datacenter complexity. System z The flagship for IBM Systems innovation and the heart of a highly secure, resilient and integrated

More information

Executive Summary. At a high level there are several options if you have Power Nodes:

Executive Summary. At a high level there are several options if you have Power Nodes: Executive Summary The IBM PureFlex System brought new levels of integration and quick time to deploy advantages that were enjoyed by many customers. A central piece of the integration was the Flexible

More information

AIX Academy Bootcamp in Sofia, Spring 2017 Accelerated, practically oriented course for AIX Power Administrators

AIX Academy Bootcamp in Sofia, Spring 2017 Accelerated, practically oriented course for AIX Power Administrators AIX Academy Bootcamp in Sofia, Spring 2017 Accelerated, practically oriented course for AIX Power Administrators Intensive training based on the official IBM course materials for AIX Administration Course

More information

64K page size enablement of Active Memory Expansion

64K page size enablement of Active Memory Expansion 64K page size enablement of Active Memory Expansion Table of Contents 1.Overview...3 2.Prerequisites to enable all page sizes in an AME environment...3 3.Enabling all AIX supported page sizes in an AME

More information

IBM PowerVM for Growing Businesses: Managing and Monitoring a Virtual Environment IBM Redbooks Solution Guide

IBM PowerVM for Growing Businesses: Managing and Monitoring a Virtual Environment IBM Redbooks Solution Guide IBM PowerVM for Growing Businesses: Managing and Monitoring a Virtual Environment IBM Redbooks Solution Guide This IBM Redbooks Solution Guide introduces IBM PowerVM virtualization technologies on IBM

More information

Best Practices: Managing AIX Updates using SUMA, NIM, and AIX Service Tools Steven Molis

Best Practices: Managing AIX Updates using SUMA, NIM, and AIX Service Tools Steven Molis using SUMA, NIM, and AIX Service Tools Steven Molis AIX Development smolis@us.ibm.com Table of Contents 1 INTRODUCTION... 3 2 BEST PRACTICES USING SUMA AND NIM... 4 2.1 GETTING UPDATES FOR A SINGLE SYSTEM

More information

Veritas InfoScale 7.0 Virtualization Guide - AIX

Veritas InfoScale 7.0 Virtualization Guide - AIX Veritas InfoScale 7.0 Virtualization Guide - AIX November 2015 Veritas InfoScale 7.0 Virtualization Guide The software described in this book is furnished under a license agreement and may be used only

More information

C IBM AIX Administration V1

C IBM AIX Administration V1 C9010-022 - IBM AIX Administration V1 1.The system administrator ran the following command to backup his image repository, but nothing was backed up to the file. Why? find /media -print backup -I-f-p /dev/rmt0

More information

IBM EXAM QUESTIONS & ANSWERS

IBM EXAM QUESTIONS & ANSWERS IBM 000-105 EXAM QUESTIONS & ANSWERS Number: 000-105 Passing Score: 650 Time Limit: 60 min File Version: 65.5 http://www.gratisexam.com/ IBM 000-105 EXAM QUESTIONS & ANSWERS Exam Name: Power Systems with

More information

IBM SAP Technical Brief. Live Partition Migration of SAP Systems Under Load. IBM SAP International Competence Center Walldorf, Germany

IBM SAP Technical Brief. Live Partition Migration of SAP Systems Under Load. IBM SAP International Competence Center Walldorf, Germany IBM SAP Technical Brief Live Partition Migration of SAP Systems Under Load IBM SAP International Competence Center Walldorf, Germany Version: 1.0 Status: April 2011 Page 1 of 19 Preface Edition Notice

More information

IBM i supports additional IBM POWER6 hardware

IBM i supports additional IBM POWER6 hardware , dated April 28, 2009 IBM i supports additional IBM POWER6 hardware Table of contents 1 At a glance 6 Product number 1 Overview 6 Ordering information 2 Key prerequisites 8 Prices 2 Planned availability

More information

Software Editions. Systems Software leadership for innovation. Mike Perry IT Specialist IBM Systems & Technology Group.

Software Editions. Systems Software leadership for innovation. Mike Perry IT Specialist IBM Systems & Technology Group. Software Editions Systems Software leadership for innovation Mike Perry IT Specialist IBM Systems & Technology Group 1 Enterprise Edition Offerings AIX Systems Director VMControl (VMControl is a bundled

More information

Planning and Sizing Virtualization. Jaqui Lynch Architect, Systems Engineer Mainline Information Systems

Planning and Sizing Virtualization.   Jaqui Lynch Architect, Systems Engineer Mainline Information Systems Planning and Sizing Virtualization http://www.circle4.com/papers/ukcmgvirt.pdf Jaqui Lynch Architect, Systems Engineer Mainline Information Systems 1 What is a CPU Chips are dual or quad core But in IBMese

More information

A Mainframe Guy Discovers Blades..as in zenterprise Blade Extension

A Mainframe Guy Discovers Blades..as in zenterprise Blade Extension SHARE in Anaheim March 2011 A Mainframe Guy Discovers Blades..as in zenterprise Blade Extension Session ID: zzs18 Glenn Anderson, IBM Training 2011 IBM Corporation 1 2 3 1999 History of Blades.. Data center

More information

June IBM Power Academy. IBM PowerVM memory virtualization. Luca Comparini STG Lab Services Europe IBM FR. June,13 th Dubai

June IBM Power Academy. IBM PowerVM memory virtualization. Luca Comparini STG Lab Services Europe IBM FR. June,13 th Dubai June 2012 @Dubai IBM Power Academy IBM PowerVM memory virtualization Luca Comparini STG Lab Services Europe IBM FR June,13 th 2012 @IBM Dubai Agenda How paging works Active Memory Sharing Active Memory

More information

IBM Power Systems Technical Support for AIX and Linux. Download Full Version :

IBM Power Systems Technical Support for AIX and Linux. Download Full Version : IBM 000-330 Power Systems Technical Support for AIX and Linux Download Full Version : https://killexams.com/pass4sure/exam-detail/000-330 A. 520 2-core, 2 active B. 550 2-core, 2 active C. 570 8-core,

More information

Power 795. New High-end 24 to 256 Cores

Power 795. New High-end 24 to 256 Cores New Power 795 New High-end 24 to 256 Cores 8 8 TB memory TurboCore 3.7, 4.0 or 4.25 GHz 1,000 VMs* with PowerVM Capacity on Demand Enterprise RAS 24x7 Warranty PowerCare 1 * Statement of Direction System

More information

Live Partition Mobility ESCALA REFERENCE 86 A1 85FA 01

Live Partition Mobility ESCALA REFERENCE 86 A1 85FA 01 Lie Partition Mobility ESCALA REFERENCE 86 A1 85FA 01 ESCALA Lie Partition Mobility Hardware May 2009 BULL CEDOC 357 AVENUE PATTON B.P.20845 49008 ANGERS CEDE 01 FRANCE REFERENCE 86 A1 85FA 01 The following

More information

Implementing Live Partition Mobility Lab Ted Sullivan In this lab you will implement the Live Partition Mobility feature Lab Intermediate

Implementing Live Partition Mobility Lab Ted Sullivan In this lab you will implement the Live Partition Mobility feature Lab Intermediate AIX Preparing for Live Partition Mobility Operations This session covers the configuration requirements for relocating logical partitions from one server to another using Live Partition Mobility. Checklists

More information

Table of Contents. Course Introduction. Table of Contents Getting Started About This Course About CompTIA Certifications. Module 1 / Server Setup

Table of Contents. Course Introduction. Table of Contents Getting Started About This Course About CompTIA Certifications. Module 1 / Server Setup Table of Contents Course Introduction Table of Contents Getting Started About This Course About CompTIA Certifications Module 1 / Server Setup Module 1 / Unit 1 Servers and Racks Server Hardware and Software

More information

MAX Data 1.1 Installation and Setup Guide. November _A0

MAX Data 1.1 Installation and Setup Guide. November _A0 MAX Data 1.1 Installation and Setup Guide November 2018 215-13646_A0 doccomments@netapp.com 2 Contents Deciding whether to use this guide... 4 Understanding the MAX Data components... 5 Setup overview...

More information

IBM Tivoli Storage Manager Version Introduction to Data Protection Solutions IBM

IBM Tivoli Storage Manager Version Introduction to Data Protection Solutions IBM IBM Tivoli Storage Manager Version 7.1.6 Introduction to Data Protection Solutions IBM IBM Tivoli Storage Manager Version 7.1.6 Introduction to Data Protection Solutions IBM Note: Before you use this

More information

ForeScout CounterACT. Resiliency Solutions. CounterACT Version 8.0

ForeScout CounterACT. Resiliency Solutions. CounterACT Version 8.0 ForeScout CounterACT Resiliency Solutions CounterACT Version 8.0 Table of Contents About ForeScout Resiliency Solutions... 4 Comparison of Resiliency Solutions for Appliances... 5 Choosing the Right Solution

More information

IBM System p5 570 POWER5+ processor and memory features offer new options

IBM System p5 570 POWER5+ processor and memory features offer new options Hardware Announcement February 14, 2006 IBM System p5 570 POWER5+ processor and memory features offer new options Overview The System p5 570 offers new POWER5+ processor options with 64-bit 1.9 GHz and

More information

IBM Exam AIX 7 Administration Version: 9.1 [ Total Questions: 229 ]

IBM Exam AIX 7 Administration Version: 9.1 [ Total Questions: 229 ] s@lm@n IBM Exam 000-221 AIX 7 Administration Version: 9.1 [ Total Questions: 229 ] Topic 2, Volume B Question No : 1 - (Topic 2) An administrator migrated a global environment of AIX 6 to AIX 7 using NIM.

More information

IBM Spectrum Protect Version Introduction to Data Protection Solutions IBM

IBM Spectrum Protect Version Introduction to Data Protection Solutions IBM IBM Spectrum Protect Version 8.1.2 Introduction to Data Protection Solutions IBM IBM Spectrum Protect Version 8.1.2 Introduction to Data Protection Solutions IBM Note: Before you use this information

More information

Dell Fluid Data solutions. Powerful self-optimized enterprise storage. Dell Compellent Storage Center: Designed for business results

Dell Fluid Data solutions. Powerful self-optimized enterprise storage. Dell Compellent Storage Center: Designed for business results Dell Fluid Data solutions Powerful self-optimized enterprise storage Dell Compellent Storage Center: Designed for business results The Dell difference: Efficiency designed to drive down your total cost

More information

IBM Power Facts and Features IBM Power Systems, IBM PureFlex and Power Blades

IBM Power Facts and Features IBM Power Systems, IBM PureFlex and Power Blades IBM Power Facts and Features IBM Power Systems, IBM PureFlex and Power Blades October 2012 IBM Power Systems servers and IBM BladeCenter blade servers using IBM POWER6 and POWER6+ processors are described

More information

Disk I/O and the Network

Disk I/O and the Network Page 1 of 5 close window Print Disk I/O and the Network Increase performance with more tips for AIX 5.3, 6.1 and 7 October 2010 by Jaqui Lynch Editor s Note: This is the concluding article in a two-part

More information

VIOS NextGen: Server & Storage Integration

VIOS NextGen: Server & Storage Integration IBM Power Systems Technical University October 18 22, 2010 Las Vegas, NV NextGen: Server & Storage Integration Session ID: VM19 PowerVM : Virtualization for IBM Power Systems Speaker Name: Bob Kovacs All

More information

41CO Operation and Maintaining PowerVM VIOS with IBM i

41CO Operation and Maintaining PowerVM VIOS with IBM i 41CO Operation and Maintaining PowerVM VIOS with IBM i Gary Konicek konicek@us.ibm.com IBM Lab Services Session ID: Agenda Key: 170299 41CO Fix Strategy before June 2015 Base releases: i.e. 2.2.1.0 i.e.

More information

Managing VMware ESXi in the Datacenter. Dwarakanath P Rao Sr Partner consultant 6 th November 2008

Managing VMware ESXi in the Datacenter. Dwarakanath P Rao Sr Partner consultant 6 th November 2008 Managing VMware ESXi in the Datacenter Dwarakanath P Rao Sr Partner consultant 6 th November 2008 Agenda VMware ESXi Overview ESXi Getting Started Case Studies VMware ESXi Overview Next What generation

More information

AIX Power System Assessment

AIX Power System Assessment When conducting an AIX Power system assessment, we look at how CPU, Memory and Disk I/O are being consumed. This can assist in determining whether or not the system is sufficiently sized. An undersized

More information

IBM Tivoli Storage Manager for HP-UX Version Installation Guide IBM

IBM Tivoli Storage Manager for HP-UX Version Installation Guide IBM IBM Tivoli Storage Manager for HP-UX Version 7.1.4 Installation Guide IBM IBM Tivoli Storage Manager for HP-UX Version 7.1.4 Installation Guide IBM Note: Before you use this information and the product

More information

IBM Testpapers Now with Questions & Answers

IBM Testpapers Now with Questions & Answers IBM Testpapers 000-783 Now with Questions & Answers Number: 000-783 Passing Score: 660 Time Limit: 90 min File Version: 24.6 http://www.gratisexam.com/ Pass IBM 000-783 Now with Questions & Answers Exam

More information

HP Supporting the HP ProLiant Storage Server Product Family.

HP Supporting the HP ProLiant Storage Server Product Family. HP HP0-698 Supporting the HP ProLiant Storage Server Product Family https://killexams.com/pass4sure/exam-detail/hp0-698 QUESTION: 1 What does Volume Shadow Copy provide?. A. backup to disks B. LUN duplication

More information

IBM SmartCloud Entry. Administrator Guide 2.3

IBM SmartCloud Entry. Administrator Guide 2.3 IBM SmartCloud Entry Administrator Guide 2.3 IBM SmartCloud Entry Administrator Guide 2.3 Note Before using this information and the product it supports, read the information in Notices on page 115. Second

More information

p5 520 server Robust entry system designed for the on demand world Highlights

p5 520 server Robust entry system designed for the on demand world Highlights Robust entry system designed for the on demand world IBM p5 520 server _` p5 520 rack system with I/O drawer Highlights Innovative, powerful, affordable, open and adaptable UNIX and Linux environment system

More information