The Contents and Structure of this Manual. This document is composed of the following 12 chapters.
|
|
- Penelope Craig
- 6 years ago
- Views:
Transcription
1
2
3 Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000 model 700, 800, 900, 1100, 1200, 2100, or 2200 Disk storage system to a server running AIX via a Fibre Channel interface. This document should be used in conjunction with any other applicable user manuals, such as those for the ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000 model 700, 800, 900, 1100, 1200, 2100, or 2200 Disk storage system, server, OS used, Fibre Channel cards, drivers, etc. Note that this manual refers the following documents: Server Support Matrix Server Support Matrix for FC-SWITCH ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) Fibre Channel Switch Settings ETERNUSmgr Install Guide ETERNUSmgr User Guide Also, note that in this document the ETERNUS2000 models 100 and 200, ETERNUS4000 models 300, 400, 500, and 600, and ETERNUS8000 models 700, 800, 900, 1100, 1200, 2100, and 2200 Disk storage systems are collectively referred to as ETERNUS Disk storage systems. Fifth Edition December 2010 The Contents and Structure of this Manual This document is composed of the following 12 chapters. Chapter 1 Workflow This describes how to connect the ETERNUS Disk storage system to a server. Chapter 2 Checking the Server Environment This describes which servers can be connected to ETERNUS Disk storage systems. Chapter 3 Notes This describes issues that should be noted when connecting the ETERNUS Disk storage systems and server. Chapter 4 Checking the Server Information This describes how to check the server's WWN (World Wide Name). 3
4 Preface Chapter 5 Installing and Setting up ETERNUSmgr This describes how to install ETERNUSmgr. Chapter 6 Setting up the ETERNUS Disk Storage Systems This describes how to use ETERNUSmgr to set up the ETERNUS Disk storage systems. Chapter 7 Setting up the Fibre Channel Switches This describes how to setup the Fibre Channel switches. Chapter 8 Installing Drivers and Setting up the Server This describes the driver and server settings. Chapter 9 Checking Connections This describes how to check the connection status between server and ETERNUS Disk storage systems. Chapter 10 Setting up the Multipath Configuration This describes the settings when operating with a multipath configuration. Chapter 11 Creating Volumes This describes how to create a volume on the ETERNUS Disk storage systems. Chapter 12 SAN Boot This provides notes for a SAN Boot. Safe Use of this Product Using this manual This manual contains important information to ensure the safe use of this product. Be sure to thoroughly read and understand its contents before using the product. After reading, store this manual in a safe place for future reference. FUJITSU has made every effort to ensure the safety of the users and other personnel, and to prevent property damage. When using this product, carefully follow the instructions described in this manual. 4
5 Preface Acknowledgments AIX, RS/6000, pseries, System p, and Power are trademarks of IBM Corp. in the U.S. and other countries. Symantec, Symantec logo, VERITAS, and VERITAS logo are registered trademarks of Symantec Corp. in the U.S. and its affiliated companies. VERITAS Volume Manager and VERITAS Cluster Server are trademarks of Symantec Corp. and its affiliated companies. The company names, product names and service names mentioned in this document are registered trademarks or trademarks of their respective companies. Naming Conventions Other names "Channel Adapter" (CA) refers to a Fibre Channel interface module used in the ETERNUS Disk storage systems to connect to the server. "Fibre Channel card" refers to the Fibre Channel interface module normally used in the server. A "Host Bus Adapter" (HBA) or "Channel Adapter" (CA) may be used instead, depending on the server. Italics are used to show variables such as values and characters that appear in command parameters and output examples. 5
6 Contents Chapter 1 Workflow...8 Chapter 2 Checking the Server Environment Hardware OS Fibre Channel Cards VERITAS Volume Manager (VxVM) VERITAS Cluster Server (VCS) Chapter 3 Notes Setup Notes for the ETERNUS Disk Storage Systems Notes Regarding the Number of LUNs Fibre Channel Switch Notes LVM Notes Server Startup and Power Supply Control Notes VERITAS Volume Manager (VxVM) Notes VERITAS Cluster Server (VCS) Notes Multipath Notes Virtual I/O Server (VIOS) Notes Chapter 4 Checking the Server Information...17 Chapter 5 Installing and Setting up ETERNUSmgr...18 Chapter 6 Setting up the ETERNUS Disk Storage Systems...19 Chapter 7 Setting up the Fibre Channel Switches...20 Chapter 8 Installing Drivers and Setting up the Server Installing the Drivers Setting the Driver Parameters Installing the Multipath Driver Installing the FJspio Package Chapter 9 Checking Connections Turning on the Devices
7 Contents 9.2 Logical Unit Recognition Setting Logical Units Chapter 10 Chapter 11 Setting up the Multipath Configuration...26 Creating Volumes Creating the Volume Groups Creating the Logical Volumes Chapter 12 SAN Boot
8 Chapter 1 Workflow Applicable reference documents vary depending on the connection environment. The documents and workflow required are as follows. Documents required in the workflow: Server Support Matrix Server Support Matrix for FC-SWITCH ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) Fibre Channel Switch Settings ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for AIX (this manual) ETERNUSmgr Install Guide ETERNUSmgr User Guide Manuals supplied with the server, Fibre Channel card, Fibre Channel card driver, and Multipath Driver 8
9 Chapter 1 Workflow > Workflow Install ETERNUSmgr and set up the ETERNUS Disk storage system Refer If ETERNUSmgr is to be used, install it and set up the ETERNUS Disk storage system, and identify the WWNs of the server-side Fibre Channel cards (required later). - "Chapter 4 Checking the Server Information" (page 17) - "Chapter 5 Installing and Setting up ETERNUSmgr" (page 18) - "Chapter 6 Setting up the ETERNUS Disk Storage Systems" (page 19) - Install ETERNUSmgr. ETERNUSmgr Install Guide - Check ETERNUSmgr operation. ETERNUSmgr User Guide - Set up the ETERNUS Disk storage system. ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings Set up the Fibre Channel Switches If a Fibre Channel switch is to be used, set it up now. Refer - Set up the Fibre Channel switch. "Chapter 7 Setting up the Fibre Channel Switches" (page 20) ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings - Check the Fibre Channel switch connection requirements. Server Support Matrix for FC-SWITCH 9
10 Chapter 1 Workflow > Install the Fibre Channel Card Drivers and Set the Parameters Refer Install the Fibre Channel card drivers, and set up the server environment. - "8.1 Installing the Drivers" (page 21) - "8.2 Setting the Driver Parameters" (page 21) - Check the driver version for the Fibre Channel card being used. Server Support Matrix (If the ETERNUS MPIO for IBM AIX or ETERNUS Multipath Driver is used) (If single-path connection or VERITAS VOLUME Manager is used) Install the Multipath Driver Install the ETERNUS Multipath Driver before using it. Refer - "8.3 Installing the Multipath Driver" (page 23) - Install the Multipath Driver. Installation & Configuration Guide Install the FJspio Install the FJspio. Refer - "8.4 Installing the FJspio Package" (page 23) Set the Server to Recognize the Logical Units Set up the server so that it can recognize the ETERNUS Disk storage systems' LUNs (logical units). Refer - "9.2 Logical Unit Recognition" (page 24) 10
11 Chapter 1 Workflow > Configure the Server Refer Set up the server as required by the system configuration. - Multipath configurations ETERNUS Multipath Driver or ETERNUS MPIO for IBM AIX - "Chapter 10 Setting up the Multipath Configuration" (page 26) Set up Dynamic Multipathing (DMP) with VERITAS Volume Manager (VxVM) - "3.6 VERITAS Volume Manager (VxVM) Notes" (page 15) - Volume manager Logical Volume Manager (LVM) - "Chapter 11 Creating Volumes" (page 27) VERITAS Volume Manager (VxVM) - "3.6 VERITAS Volume Manager (VxVM) Notes" (page 15) Create the Volumes Create LVM logical volumes. Refer - "Chapter 11 Creating Volumes" (page 27) 11
12 Chapter 2 Checking the Server Environment Refer to the "Server Support Matrix" to check the server environment. 2.1 Hardware Refer to the "Server Support Matrix" for details. 2.2 OS Refer to the "Server Support Matrix" for details. 2.3 Fibre Channel Cards Refer to the "Server Support Matrix" for details. 2.4 VERITAS Volume Manager (VxVM) Refer to the "Server Support Matrix" to check the compatibility of AIX and VxVM versions. 2.5 VERITAS Cluster Server (VCS) Refer to the "Server Support Matrix" to check the compatibility of AIX and VCS versions. 12
13 Chapter 3 Notes Note the following issues when performing the relevant operation. 3.1 Setup Notes for the ETERNUS Disk Storage Systems The following settings will depend on the exact connection conditions. Host Response settings "Host Specific Mode" and "Reservation Conflict Response for Test Unit Ready" settings Reset Group settings Refer to the following manual for the appropriate settings. ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings 3.2 Notes Regarding the Number of LUNs The maximum number of LUNs vary according to the system environment. System environment ETERNUS Disk storage systems ETERNUS2000 ETERNUS4000 models 300 and 500 ETERNUS8000 models 700, 900, 1100, and 2100 ETERNUS4000 models 400 and 600 ETERNUS8000 models 800, 1200, and 2200 Single path (FJspio) environment ETERNUS Multipath Driver 1.0.x environment ETERNUS MPIO for IBM AIX 2.0.x environment ETERNUS Multipath Driver 2.0 environment Maximum 256 LUNs Maximum 128 LUNs Maximum 256 LUNs Maximum 256 LUNs Maximum 128 LUNs Maximum 256 LUNs Maximum 512 LUNs Maximum 128 LUNs Maximum 512 LUNs Exact details will depend on the OS being used, but there are no specific multipath driver restrictions. 13
14 Chapter 3 Notes > 3.3 Fibre Channel Switch Notes 3.3 Fibre Channel Switch Notes Which Fibre Channel switches can be connected to the ETERNUS Disk storage system varies depending on the connection environment (server OS and ETERNUS Disk storage system model). Refer to the "Server Support Matrix for FC-SWITCH" before starting. When using a Fibre Channel switch (ETERNUS SN200 series, Brocade DCX series) between the server and ETERNUS Disk storage system, refer to the "ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) Fibre Channel Switch Settings" for help in preparing and setting up the Fibre Channel switch. If AIX server is connected to a Fibre Channel switch, the Fibre Channel switch port link speed must be set. Set the link speed of the Fibre Channel switch ports according to the link speeds of the server-side Fibre Channel cards, as follows: Fibre Channel card (Maximum link speed) Paired devices Fibre Channel switch (Maximum link speed) 8Gbps 8Gbps 8Gbps fixed 4Gbps 4Gbps fixed 2Gbps 2Gbps fixed 4Gbps 8Gbps 4Gbps fixed 4Gbps 2Gbps 2Gbps fixed 2Gbps 8Gbps 2Gbps fixed 4Gbps 2Gbps Set the Fibre Channel switch port link speed to... If the devices being connected together both have automatically set link speeds, the resulting link speed may be less than optimal. The default link speed setting for Fibre Channel switch ports is "Automatic". The link speed setting for true IBM Fibre Channel cards is always "Automatic". The link speed setting of a true IBM Fibre Channel card cannot be changed to other than "Automatic", so the Fibre Channel switch port link speeds must be fixed to match the actual speed of the server-side Fibre Channel cards, as per the above table, so that the same link speed is always used. 3.4 LVM Notes Disable [Bad Block Relocation] for a LVM logical volume that was created on ETERNUS Disk storage systems' LUN. Also, [Bad Block Relocation] must be disabled for the logical volume in which file system logs are stored. 14
15 Chapter 3 Notes > 3.5 Server Startup and Power Supply Control Notes 3.5 Server Startup and Power Supply Control Notes Before turning the server on, check that the ETERNUS Disk storage systems and Fibre Channel switches are all "Ready". If the server is turned on and they are not "Ready", the server will not be able to recognize the ETERNUS Disk storage systems. Also, when the ETERNUS Disk storage system power supply is being controlled by a connected server, make sure that the ETERNUS Disk storage system does not shut down before the connected servers. Similarly, the Fibre Channel switches must also be turned off after the connected servers have been shut down. If turned off, data writes from the running server cannot be saved to the ETERNUS Disk storage systems, and already saved data may also be affected. 3.6 VERITAS Volume Manager (VxVM) Notes Refer to "8.4 Installing the FJspio Package" and install the FJspio package on the AIX system before installing VxVM. Install VERITAS Array Support Library after installing VxVM. Installing VxVM VxVM should be installed as specified in its accompanying documentation. To use VxVM, set the Fibre Channel card parameters that are specified in the VxVM documentation. When using VxVM 4.0 or VxVM 5.0 If the ETERNUS Disk storage systems are connected to a configuration that uses the VxVM, the VERITAS Array Support Library (ASL) will also need to be installed. Which version of VERITAS ASL is required will depend on the storage system and version of VxVM used. Download the VERITAS ASL version that matches your environment from the following Symantec web-site. Refer to the Symantec web-site for VERITAS ASL installation details. Storage system VxVM ASL download URL ETERNUS2000 VxVM 5.0 MP1 or later ETERNUS4000 ETERNUS8000 VxVM 4.0 MP3 or later VxVM 5.0 MP1 or later When using VxVM 5.1 ASL does not need to be installed VERITAS Cluster Server (VCS) Notes VERITAS Cluster Server should be installed according to the directions given in the documentation provided with VERITAS Cluster Server. 15
16 Chapter 3 Notes > 3.8 Multipath Notes 3.8 Multipath Notes Refer to the "Server Support Matrix" for details of the different combinations of Multipath configurations. 3.9 Virtual I/O Server (VIOS) Notes Perform the settings described in this document only for a VIOS. When setting the VIOS, the root privilege for the VIOS environment is required. Make sure to install ETERNUS Multipath Driver 2.0 on the VIOS. When installing software on a VIOS, the root privilege for the VIOS environment is required. Only a virtual SCSI adapter connection is supported. Assign hdisk to the virtual SCSI adapter. Configuring LVM on the VIOS is not supported. 16
17 Chapter 4 Checking the Server Information Check the World Wide Name (WWN). Execute the following command to display the WWN of fcs0. # lscfg -vl fcs0 The WWN is displayed in the [Network Address]. If multiple Fibre Channel cards are installed, change the parameter and reexecute the command. 17
18 Chapter 5 Installing and Setting up ETERNUSmgr If ETERNUSmgr is to be used, install it according to the directions given in the "ETERNUSmgr Install Guide". After the installation, set up ETERNUSmgr following the instructions in the "ETERNUSmgr User Guide". 18
19 Chapter 6 Setting up the ETERNUS Disk Storage Systems Set up the ETERNUS Disk storage systems using ETERNUSmgr. ETERNUS Disk storage systems' setup can be performed independently of server setup. For details on how to perform these settings, refer to the "ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings" and "ETERNUSmgr User Guide". 19
20 Chapter 7 Setting up the Fibre Channel Switches This chapter describes the settings required to connect a server and ETERNUS Disk storage system via a Fibre Channel switch. Perform the settings according to the procedure given in "ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) Fibre Channel Switch Settings". 20
21 Chapter 8 Installing Drivers and Setting up the Server 8.1 Installing the Drivers Install the necessary drivers and patches following the Fibre Channel card installation guide. 8.2 Setting the Driver Parameters After the driver has been installed, its parameters need to be set. Perform the following procedure to get the server to recognize the Fibre Channel card. Procedure 1 Use the "cfgmgr" command to force the server to recognize the Fibre Channel card configuration. # cfgmgr -v 2 Use the "lsdev" command to check the resulting configuration. # lsdev -C If there is a "fscsin" entry (where "N" is a number) corresponding to the Fibre Channel card displayed, delete the fscsin device temporarily using the "rmdev" command to change the fscsin device parameter. The deleted fscsin device will be recreated after rebooting or at the next "cfgmgr" command execution. Enter the fscsi number to delete for "N". # rmdev -Rdl fscsin 3 Use the "smit" command to set the driver parameters. #smit The [System Management] menu is displayed. 21
22 Chapter 8 Installing Drivers and Setting up the Server > 8.2 Setting the Driver Parameters 4 Select the following menu items in order. (1) [Devices] (2) [FC Adapter] (3) [FC Adapter] (4) [Change / Show Characteristics of a FC Adapter] A window to select the Fibre Channel card to be set will appear. 5 Select the Fibre Channel card. The [Change/Show Characteristics of a FC Adapter] window will appear. 6 Input a value for [Maximum number of COMMANDS to queue to the adapter]. For ETERNUS2000, input the value calculated by the following formula: Value (round the result down) = 40 / No. of Fibre Channel cards per CA port Use the value of "20" if the actual result is lower. For ETERNUS4000 or ETERNUS8000, just enter "40". If the ETERNUS2000 is connected to a Fibre Channel switch via multiple ports, and the above formula does not gives the same value for each port, use the minimum value obtained. 7 Select the [INIT Link flags] value. For FC-AL connection, select [al]. For fabric connection, select [pt2pt]. Some HBAs (i.e. 5735) are set as "Auto" and the setting cannot be changed. Use those HBAs as they are, in the "Auto" setting. Perform the procedures below in Step 8 Step 11 only when a VIOS is configured. 8 Return to the [System Management] menu and select the following menu items in order. (1) [Devices] (2) [FC Adapter] (3) [FC SCSI I/O Controller Protocol Device] (4) [Change / Show Characteristics of a FC SCSI Protocol Device] A window to select the FC SCSI protocol device to be set will appear. 9 Select the HBA port to be set. 10 Set "no" for [Dynamic Tracking of FC Devices]. 11 Set "fast_fail" for [FC Fabric Event Error RECOVERY Policy]. 22
23 Chapter 8 Installing Drivers and Setting up the Server > 8.3 Installing the Multipath Driver 12 After the settings are complete, exit the "smit" command. End of procedure 8.3 Installing the Multipath Driver Install the ETERNUS Multipath Driver by following the manual provided with the Multipath Driver. 8.4 Installing the FJspio Package FJspio is used to register the ETERNUS Disk storage system on the AIX server's ODM. The FJspio package must be installed in both of the following cases: Single-path connection is used Multi-path connection is configured using VxVM FJspio package installation conditions: Storage system FJspio package version Remarks ETERNUS2000 ETERNUS4000, and ETERNUS8000 FJspio_1_5_0_16 or later Contact your Fujitsu sales representative or engineer for details on obtaining the FJspio package. Refer to "readme_fjspio" included in the FJspio package for instructions about how to install the FJspio package. When a Multipath Driver is used, the FJspio package does not need to be installed. This is because the Multipath Driver provides the same functions as FJspio. 23
24 Chapter 9 Checking Connections 9.1 Turning on the Devices To turn on the connected devices, use the following procedures: Procedure 1 Turn on the Fibre Channel switch power (if used). 2 After checking that the Ready (or equivalent) LED of the Fibre Channel switch is lit, turn on the ETERNUS Disk storage systems. 3 After checking that the ETERNUS Disk storage systems Ready LED is lit, turn on the server. End of procedure 9.2 Logical Unit Recognition The ETERNUS Disk storage systems' LUNs (Logical Units) recognized by the server are used as physical volumes (hdisks). The "lsdev" command can be used to display them. Logical unit (LUN) recognition in FJspio environment (example for the ETERNUS2000) #lsdev -Cc disk hdisk0 Available 1S ,0 16 Bit LVD SCSI Disk Drive hdisk1 Available 1S ,0 16 Bit LVD SCSI Disk Drive hdisk2 Available E Fujitsu Storage Systems ETERNUS (example for the ETERNUS4000) #lsdev -Cc disk hdisk0 Available 1S ,0 16 Bit LVD SCSI Disk Drive hdisk1 Available 1S ,0 16 Bit LVD SCSI Disk Drive hdisk2 Available E Fujitsu Storage Systems ETERNUS 24
25 Chapter 9 Checking Connections > 9.3 Setting Logical Units (example for the ETERNUS8000) #lsdev -Cc disk hdisk0 Available 1S ,0 16 Bit LVD SCSI Disk Drive hdisk1 Available 1S ,0 16 Bit LVD SCSI Disk Drive hdisk2 Available E Fujitsu Storage Systems ETERNUS 9.3 Setting Logical Units Set the parameters for the LUNs that are recognized by the VIOS. IMPORTANT The following procedure is not required when a VIOS is not configured. Perform the following procedure using the padmin user account. Procedure 1 Use the "chdev" command to set the reserve policy. Enter the hdisk number to set for "N". $ chdev -dev hdiskn -attr reserve_policy=no_reserve 2 Use the "lsdev" command to check the configured settings. Enter the hdisk number to set for "N". $ lsdev -dev hdiskn -attr End of procedure 25
26 Chapter 10 Setting up the Multipath Configuration Set up the ETERNUS Multipath Driver by following the manual provided with the Multipath Driver. 26
27 Chapter 11 Creating Volumes Create a volume group, logical volume and file system. LVM on the VIOS is not supported. Do not perform any of the procedures described in this chapter on a VIOS Creating the Volume Groups To create logical volumes, use the "smit" command. Procedure 1 Execute the "smit" command. The [System Management] menu is displayed. 2 Select in the following order: (1) [System Storage Management (Physical & Logical Storage) (2) [Logical Volume Manager] (3) [Volume Group] (4) [Add a Volume Group] The [Add a Volume Group] window will appear. 27
28 Chapter 11 Creating Volumes > 11.1 Creating the Volume Groups 3 Specify the following items. Specify any name for the [VOLUME GROUP name]. Be sure to specify the [PHYSICAL VOLUME names]. 4 After the settings are completed, exit the "smit" command. 5 Check the contents of the new volume group. Use the "lsvg" command to discover the number of physical partitions (the "Total PPs" value). This is required in "11.2 Creating the Logical Volumes" (page 29). raid_vg2 raid_vg3 raid_vg4 raid_vg5 # lsvg raid_vg6 VOLUME GROUP: raid_vg6 VG IDENTIFIER: ca57abbe2b VG STATE: active PP SIZE: 4 megabyte(s) VG PERMISSION: read/write TOTAL PPs: 511 (2044 megabytes) MAX LVs: 256 FREE pps: 10 (40 megabytes) LVs: 2 USED PPs: 501 (2004 megabytes) OPEN LVs: 2 QUORUM: 2 TOTAL PVs: 2 VG DESCRIPTORES: 2 STALE PVs: 0 STALE PPs: 0 AVTIVE PVs: 1 AUTO ON: yes MAX PPs per PV: MAX PVs: 2 End of procedure 28
29 Chapter 11 Creating Volumes > 11.2 Creating the Logical Volumes 11.2 Creating the Logical Volumes To create logical volumes, use the "smit" command. Procedure 1 Execute the "smit" command. The [System Management] menu is displayed. 2 Select in the following order: (1) [System Storage Management (Physical & Logical Storage)] (2) [Logical Volume Manager] (3) [Logical Volume] (4) [Add a Logical Volume] 3 Specify a [VOLUME GROUP name]. Either type a name in the [Entry Field], or press the [F4] key to select a name from the list. 29
30 Chapter 11 Creating Volumes > 11.2 Creating the Logical Volumes The [Add a Logical Volume] window will appear. 4 Specify the following items. Specify any name for the [Logical volume NAME]. Specify the [Number of LOGICAL PARTITIONS], according to the following formula. Logical volume capacity = logical partition size number of logical partitions Also, when creating a file system, a Journal Log is also created on the same disk, so be sure to leave at least one logical partition in the Volume Group. Regarding [Enable BAD BLOCK relocation?], be sure to specify "no". 5 After the settings are completed, exit the "smit" command. 6 Check the contents of the created logical volume. If the logical volume name is "raid_lv6", execute the command as follows: # lslv raid_lv6 30
31 Chapter 11 Creating Volumes > 11.2 Creating the Logical Volumes 7 Check that the [BB POLICY:] parameter is shown as "non-relocatable". If not, re-execute the "smit" command and try again. LOGICAL VOLUME: raid_lv6 VOLUME GROUP: raid_vg6 LV IDENTIFIER: ca57abbe2b.l PERMISSION: read/write VG STATE: active/complete LV STATE: opened/syncd TYPE: jfs WRITE VERIFY: off MAX LPs: 512 PP SIZE: 4 megabyte(s) COPIES: 1 SCHED POLICY: parallel LPs: 500 PPs: 500 STALE PPs: 0 BB POLICY: non-relocatable INTER-POLICY: minimum RELOCATABLE: yes INTRA-POLICY: middle UPPER BOUND: 32 MOUNT POINT: /mnt/raid_lv6 LABEL: /mnt/raid_lv6 MIRROR WRITE CONSISTENCY: on EACH LP COPY ON A SEPARATE PV?: yes Execute this command for all logical volumes created on ETERNUS Disk storage systems' LUNs to disable [Bad Block Relocation]. If [Redistribution of bad blocks] is not disabled, file system may be damaged. End of procedure 31
32 Chapter 12 SAN Boot If a logical unit (LUN) of the ETERNUS Disk storage systems is used as a boot disk, refer to "Server Support Matrix" to check the server environment. When using a LUN as a boot disk, make sure that the LUN has enough capacity to install the OS in the ETERNUS Disk storage system. Only single-path configurations are supported. 32
33 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for AIX Date of issuance: December 2010 Issuance responsibility: FUJITSU LIMITED The contents of this manual are liable to being updated without notice. While the contents of this manual are the product of all due care and diligence, no responsibility can be accepted for operational problems arising from any errors or missing information, or other use of the information contained in this manual. Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. Contents of this manual are not to be reproduced without permission from Fujitsu.
34
The Contents and Structure of this Manual. This document is composed of the following 12 chapters.
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationThis page is intentionally left blank.
This page is intentionally left blank. Preface This ETERNUS Multipath Driver User's Guide describes the features, functions, and operation of the "ETERNUS Multipath Driver" (hereafter referred to as "Multipath
More informationThe Contents and Structure of this Manual. This document is composed of the following six chapters and an appendix.
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationThe Contents and Structure of this Manual. This document is composed of the following four chapters and an appendix.
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationServer Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationThe Contents and Structure of this Manual. This document is composed of the following ten chapters.
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationServer Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationThe Contents and Structure of this Manual. This document is composed of the following three chapters and an appendix.
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Linux
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationETERNUS Disk storage systems Server Connection Guide (FCoE) for Linux
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationThe Contents and Structure of this Manual. This document is composed of the following three chapters.
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationETERNUS Disk storage systems Server Connection Guide (FCoE) for Linux
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationETERNUS Disk storage systems Server Connection Guide (FCoE) for Linux
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationServer Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationConfiguration Guide -Server Connection-
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Windows This page is intentionally left blank. Preface This manual briefly explains the operations that
More informationConfiguration Guide -Server Connection-
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Windows This page is intentionally left blank. Preface This manual briefly explains the operations that
More informationServer Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationFUJITSU Storage ETERNUS Multipath Driver 2 (for AIX) Installation Information
FUJITSU Storage ETERNUS Multipath Driver 2 (for AIX) Installation Information Oct 2016 Contents Contents... 1 Supported Operating System (OS) Versions... 1 Supported Disk Storage Systems... 1 Connection
More informationThe Contents and Structure of this Manual. This document is composed of the following two chapters.
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200 Disk storage system to a server running Solaris, HP-UX, Windows,
More informationConfiguration Guide -Server Connection-
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for VMware ESX This page is intentionally left blank. Preface This manual briefly explains the operations
More informationThe Contents and Structure of this Manual. This document is composed of the following two chapters.
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000 model 700, 800, 900, 1100, 1200,
More informationThe Contents and Structure of this Manual. This document is composed of the following six chapters and three appendices.
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationConfiguration Guide -Server Connection-
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Citrix XenServer This page is intentionally left blank. Preface This manual briefly explains the operations
More informationTechnical Note P/N REV A01 November 24, 2008
AIX Native MPIO for CLARiiON Technical Note P/N 300-008-486 REV A01 November 24, 2008 This technical note contains supplemental information about AIX Native MPIO for CLARiiON storage systems. Technical
More informationFUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for VMware ESX This page is intentionally left blank. Preface This manual briefly explains the operations that need to be performed
More informationPower Systems SAN Multipath Configuration Using NPIV v1.2
v1.2 Bejoy C Alias IBM India Software Lab Revision History Date of this revision: 27-Jan-2011 Date of next revision : TBD Revision Number Revision Date Summary of Changes Changes marked V1.0 23-Sep-2010
More informationPowerVM - Dynamically adding a Virtual Fibre Channel adapter to a client partition
Techdocs - The Technical Sales Library PowerVM - Dynamically adding a Virtual Fibre Channel adapter to a client partition Document Author: Gero Schmidt Document ID: TD105218 Doc. Organization: Technical
More informationThe Contents and Structure of this Manual. This document is composed of the following four chapters.
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationHP StorageWorks. XP Disk Array Configuration Guide for IBM AIX XP24000, XP12000, XP10000, SVS200
HP StorageWorks XP Disk Array Configuration Guide for IBM AIX XP24000, XP12000, XP10000, SVS200 Part number: A5951 047 Ninth edition: June 2007 Legal and notice information Copyright 2003, 2007 Hewlett-Packard
More informationUnit 11. Working With the Logical Volume Manager
Unit 11. Working With the Logical Volume Manager What This Unit Is About This unit provides information on how to work with logical volumes, physical volumes and volume groups. What You Should Be Able
More informationNotes for migrating to EMC or Shark with Fibre Channel boot. Planning Notes
Notes for migrating to EMC or Shark with Fibre Channel boot R. Ballough, 1/15/2004 Planning Notes 1. Reference document SANBootQA0103.pdf for a complete list of requirements when booting from SAN attached
More informationServer Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationFUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Citrix XenServer This page is intentionally left blank. Preface This manual briefly explains the operations that need to be
More informationVeritas Storage Foundation and High Availability Solutions Virtualization Guide
Veritas Storage Foundation and High Availability Solutions Virtualization Guide AIX 5.1 Service Pack 1 Veritas Storage Foundation and High Availability Solutions Virtualization Guide The software described
More informationFUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection-
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (iscsi) ETERNUS DX S4/S3 series Hybrid Storage Systems, ETERNUS AF series, ETERNUS DX200F All-Flash Arrays Settings This page
More informationETERNUS Veritas Operations Manager Storage Insight Plug-in 1.0 User s Guide P2X ENZ0
ETERNUS Veritas Operations Manager Storage Insight Plug-in 1.0 User s Guide This page is intentionally left blank. Preface This manual explains how to use and operate the ETERNUS Veritas Operations Manager
More informationIBM POWERVM WITH FLASHARRAY
IBM POWERVM WITH FLASHARRAY White paper - September 2017 Contents Executive Summary... 3 Introduction... 3 Pure Storage FlashArray... 3 IBM Power System... 3 DEVICES Virtualization With IBM PowerVM...
More informationConfiguration Guide for IBM AIX Host Attachment Hitachi Virtual Storage Platform Hitachi Universal Storage Platform V/VM
Configuration Guide for IBM AIX Host Attachment Hitachi Virtual Storage Platform Hitachi Universal Storage Platform V/VM FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-96RD636-05
More informationVeritas Storage Foundation In a VMware ESX Environment
Veritas Storage Foundation In a VMware ESX Environment Linux and Solaris x64 platforms December 2008 TABLE OF CONTENTS Introduction... 3 Executive Summary... 4 Overview... 5 Virtual Machine File System...
More informationInstallation Manual. NEXSAN MSIO for AIX. Version 2.1
NEXSAN MSIO for AIX Installation Manual Version 2.1 NEXSAN 555 St. Charles Drive, Suite 202, Thousand Oaks, CA 91360 p. 866.4.NEXSAN f. 866.418.2799 COPYRIGHT Copyright 2009 2011 by Nexsan Corporation.
More informationIBM XIV Host Attachment Kit for AIX. Version Release Notes. First Edition (September 2011)
Version 1.7.0 Release Notes First Edition (September 2011) First Edition (September 2011) This document edition applies to version 1.7.0 of the IBM XIV Host Attachment Kit for AIX software package. Newer
More informationAIX Host Utilities 6.0 Installation and Setup Guide
IBM System Storage N series AIX Host Utilities 6.0 Installation and Setup Guide GC27-3925-01 Table of Contents 3 Contents Preface... 6 Supported features... 6 Websites... 6 Getting information, help,
More informationExamples What it means
Examples What it means PHYSICAL VOLUME (PV)Represents a hard disk (hdisk0). PHYSICAL PARTITION (PP) The smallest allocation unit in the LVM. All PPs within a VG are the same si VOLUME GROUP (VG) A set
More informationThe Host Server. AIX Configuration Guide. August The Data Infrastructure Software Company
The Host Server AIX Configuration Guide August 2017 This guide provides configuration settings and considerations for SANsymphony Hosts running IBM's AIX. Basic AIX administration skills are assumed including
More informationVERITAS Storage Foundation 4.0 for Oracle
D E C E M B E R 2 0 0 4 VERITAS Storage Foundation 4.0 for Oracle Performance Brief AIX 5.2, Oracle 9iR2 VERITAS Storage Foundation for Oracle Abstract This document details the high performance characteristics
More informationWindows Host Utilities Installation and Setup Guide
IBM System Storage N series Windows Host Utilities 6.0.1 Installation and Setup Guide GC52-1295-06 Table of Contents 3 Contents Preface... 7 Supported features... 7 Websites... 7 Getting information,
More informationVeritas Storage Foundation in a VMware ESX Environment
Veritas Storage Foundation in a VMware ESX Environment Linux and Solaris x64 platforms January 2011 TABLE OF CONTENTS Introduction... 3 Executive Summary... 4 Overview... 5 Virtual Machine File System...
More informationVeritas Dynamic Multi-Pathing Administrator's Guide
Veritas Dynamic Multi-Pathing Administrator's Guide AIX DMP 5.1 Rolling Patch 1 Patch 0 Veritas Dynamic Multi-Pathing Administrator's Guide The software described in this book is furnished under a license
More informationDynamic Multi-Pathing 7.2 Administrator's Guide - AIX
Dynamic Multi-Pathing 7.2 Administrator's Guide - AIX October 2016 Dynamic Multi-Pathing Administrator's Guide Last updated: 2016-10-31 Document version: 7.2 Rev 0 Legal Notice Copyright 2016 Veritas Technologies
More informationEMC PowerPath for AIX Version 5.1
EMC PowerPath for AIX Version 5.1 Installation and Administration Guide P/N 300-005-461 REV A03 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 1997-2008
More informationDynamic Multi-Pathing 7.0 Administrator's Guide - AIX
Dynamic Multi-Pathing 7.0 Administrator's Guide - AIX December 2015 Dynamic Multi-Pathing Administrator's Guide The software described in this book is furnished under a license agreement and may be used
More informationEMC PowerPath for AIX Version 5.3
EMC PowerPath for AIX Version 5.3 Installation and Administration Guide P/N 300-008-341 REV A08 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 1997-2011
More informationVERITAS Dynamic MultiPathing (DMP) Increasing the Availability and Performance of the Data Path
White Paper VERITAS Storage Foundation for Windows VERITAS Dynamic MultiPathing (DMP) Increasing the Availability and Performance of the Data Path 12/6/2004 1 Introduction...3 Dynamic MultiPathing (DMP)...3
More informationVeritas Dynamic Multi-Pathing Administrator's Guide
Veritas Dynamic Multi-Pathing Administrator's Guide AIX 5.1 Service Pack 1 Platform Release 1 Veritas Dynamic Multi-Pathing Administrator's Guide The software described in this book is furnished under
More informationVeritas Dynamic Multi-Pathing Administrator's Guide - AIX
Veritas Dynamic Multi-Pathing 6.0.1 Administrator's Guide - AIX September 2012 Veritas Dynamic Multi-Pathing Administrator's Guide The software described in this book is furnished under a license agreement
More informationVeritas Storage Foundation and High Availability Solutions Application Note: Support for HP-UX Integrity Virtual Machines
Veritas Storage Foundation and High Availability Solutions Application Note: Support for HP-UX Integrity Virtual Machines HP-UX 11i v3 5.0.1 Veritas Storage Foundation and High Availability Solutions Application
More informationIBM XIV Host Attachment Kit for AIX Version Release Notes
IBM XIV Host Attachment Kit for AIX Version 1.8.0 Release Notes First Edition (March 2012) This document edition applies to Version 1.8.0 of the IBM IBM XIV Host Attachment Kit for AIX software package.
More informationVeritas Storage Foundation Basic - Technical FAQ January 2009
Veritas Storage Foundation Basic - Technical FAQ January 2009-1 - GENERAL QUESTIONS... 3 What is Veritas Storage Foundation Basic?... 3 What are edge-tier workloads?... 3 How much does Storage Foundation
More informationInteroperability of Bloombase StoreSafe Security Server, QLogic FC-HBAs and QLogic SAN Switch for Transparent Storage Area Network (SAN) Encryption
Bloombase Interoperability Program P1 2012 Bloombase Interoperability of Bloombase StoreSafe Security Server, QLogic FC-HBAs and QLogic SAN Switch for Transparent Storage Area Network (SAN) Encryption
More informationCore Switch PID Format Update Best Practices
Core Switch PID Format Update Best Practices For Immediate Release Updated 7/1/2002 Executive Summary There are certain parameters which must be set identically on all switches in a given fabric. In the
More informationVeritas InfoScale 7.0 Virtualization Guide - AIX
Veritas InfoScale 7.0 Virtualization Guide - AIX November 2015 Veritas InfoScale 7.0 Virtualization Guide The software described in this book is furnished under a license agreement and may be used only
More informationExpressCluster X 3.2 for Linux
ExpressCluster X 3.2 for Linux Installation and Configuration Guide 5/23/2014 2nd Edition Revision History Edition Revised Date Description 1st 2/19/2014 New manual 2nd 5/23/2014 Corresponds to the internal
More informationPART NUMBER EDITION NUMBER FLEXLINE ONLINE STORAGE SYSTEMS SOLUTIONS PRODUCT TYPE. INSTALLATION INSTRUCTIONS FOR AIX Open Systems Host Attach
PART NUMBER 96107 4 EDITION NUMBER FLEXLINE ONLINE STORAGE SYSTEMS TM INSTALLATION INSTRUCTIONS FOR AIX Open Systems Host Attach PRODUCT TYPE SOLUTIONS FlexLine 200/300 Series Installation Instructions
More informationExpressCluster X 3.1 for Linux
ExpressCluster X 3.1 for Linux Installation and Configuration Guide 10/11/2011 First Edition Revision History Edition Revised Date Description First 10/11/2011 New manual Copyright NEC Corporation 2011.
More informationVERITAS Dynamic Multipathing. Increasing the Availability and Performance of the Data Path
VERITAS Dynamic Multipathing Increasing the Availability and Performance of the Data Path 1 TABLE OF CONTENTS I/O Path Availability and Performance... 3 Dynamic Multipathing... 3 VERITAS Storage Foundation
More informationEXPRESSCLUSTER X 4.0 for Linux
EXPRESSCLUSTER X 4.0 for Linux Installation and Configuration Guide April 17, 2018 1st Edition Revision History Edition Revised Date Description 1st Apr 17, 2018 New manual. Copyright NEC Corporation 2018.
More informationEMC Simple Support Matrix
EMC Simple Support Matrix EMC Symmetrix DMX-3 and DMX-4 OCTOBER 2014 P/N 300-013-399 REV 33 2011-2014 EMC Corporation. All Rights Reserved. EMC believes the information in this publication is accurate
More informationVeritas Cluster Server Application Note: Support for HP-UX Integrity Virtual Machines. HP-UX 11i v2, HP-UX 11i v3
Veritas Cluster Server Application Note: Support for HP-UX Integrity Virtual Machines HP-UX 11i v2, HP-UX 11i v3 Augut 2009 Application Note: Veritas Cluster Server Support for HP-UX Integrity Virtual
More informationETERNUS SF AdvancedCopy Manager Glossary
ETERNUS SF AdvancedCopy Manager 14.1 Glossary J2X1-7455-02ENZ0(00) January 2010 Preface Purpose This manual describes the terminology used in the ETERNUS SF AdvancedCopy Manager manuals. Intended Readers
More informationUnit 8 System storage overview
Unit 8 System storage overview Course materials may not be reproduced in whole or in part without the prior written permission of IBM. 5.1 Unit objectives After completing this unit, you should be able
More informationIBM Storage Host Attachment Kit for AIX Version Release Notes IBM
IBM Storage Host Attachment Kit for AIX Version 2.8.0 Release Notes IBM Second Edition (October 2017) This edition applies to version 2.8.0 of the IBM Storage Host Attachment Kit for AIX software package.
More informationIBM Storage Host Attachment Kit for AIX Version Release Notes IBM
IBM Storage Host Attachment Kit for AIX Version 2.9.0 Release Notes IBM Second Edition (March 2018) This edition applies to version 2.9.0 of the IBM Storage Host Attachment Kit for AIX software package.
More informationHow to Configure NPIV in a Microsoft Hyper-V Environment
How to Configure NPIV in a Microsoft Hyper-V Environment Designed for Windows System Administrators and Storage Administrators, this document provides guidelines for configuring Microsoft Hyper-V using
More informationEnterprise Volume Management System Project. April 2002
Enterprise Volume Management System Project April 2002 Mission Statement To create a state-of-the-art, enterprise level volume management system for Linux which will also reduce the costs associated with
More informationEXPRESSCLUSTER X 3.3 for Linux
EXPRESSCLUSTER X 3.3 for Linux Installation and Configuration Guide 04/10/2017 5th Edition Revision History Edition Revised Date Description 1st 02/09/2015 New manual. 2nd 06/30/2015 Corresponds to the
More informationEMC Symmetrix with VERITAS Dynamic Multi-pathing (DMP)
EMC Symmetrix with VERITAS Dynamic Multi-pathing (DMP) Best Practices Planning Abstract This white paper provides best practices for configuring VERITAS Dynamic Multi-pathing (DMP) in an EMC Symmetrix
More informationExpressCluster X 2.0 for Linux
ExpressCluster X 2.0 for Linux Installation and Configuration Guide 03/31/2009 3rd Edition Revision History Edition Revised Date Description First 2008/04/25 New manual Second 2008/10/15 This manual has
More informationVeritas NetBackup Device Configuration Guide
Veritas NetBackup Device Configuration Guide UNIX, Windows, Linux Release 8.1 Veritas NetBackup Device Configuration Guide Last updated: 2018-02-16 Legal Notice Copyright 2018 Veritas Technologies LLC.
More informationIBM System Storage N series
IBM System Storage N series Host Settings Affected by AIX Host Utilities The AIX Host Utilities sometimes recommend that settings on the host be modified. These recommendations are based on research and
More informationVeritas Access. Installing Veritas Access in VMWare ESx environment. Who should read this paper? Veritas Pre-Sales, Partner Pre-Sales
Installing Veritas Access in VMWare ESx environment Who should read this paper? Veritas Pre-Sales, Partner Pre-Sales Veritas Access Technical Brief Contents OVERVIEW... 3 REQUIREMENTS FOR INSTALLING VERITAS
More informationOpen-FCoE Software Initiator
Open-FCoE Software Initiator Chelsio Communications, Inc. http://www.chelsio.com 1 P age Copyright 2009 Chelsio Communications, Inc. All rights reserved. 370 San Aleso Ave, Suite 100, Sunnyvale, CA 94085
More informationC exam. Number: C Passing Score: 800 Time Limit: 120 min IBM C IBM AIX Administration V1.
C9010-022.exam Number: C9010-022 Passing Score: 800 Time Limit: 120 min IBM C9010-022 IBM AIX Administration V1 Exam A QUESTION 1 A customer has a virtualized system using Virtual I/O Server with multiple
More informationVeritas Dynamic Multi-Pathing readme
Veritas Dynamic Multi-Pathing readme Linux DMP 5.1 Rolling Patch 1 Patch 0 Veritas Dynamic Multi-Pathing Readme The software described in this book is furnished under a license agreement and may be used
More informationThis guide consists of the following two chapters and an appendix. Chapter 1 Installing ETERNUSmgr This chapter describes how to install ETERNUSmgr.
Preface This installation guide explains how to install the "ETERNUSmgr for HP-UX" storage system management software on an ETERNUS DX400 series, ETERNUS DX8000 series, ETERNUS2000, ETERNUS4000, ETERNUS8000,
More informationETERNUS Multipath Driver (Oracle Solaris Version) Installation Information
ETERNUS Multipath Driver (Oracle Solaris Version) Installation Information September 2011 Contents Supported OS 1 Restrictions and Resolution schedule (the driver for Solaris 10 OS and Solaris 9 OS) 1
More informationIBM XIV Host Attachment Kit for HP-UX. Version Release Notes. First Edition (May 2011)
IBM XIV Host Attachment Kit for HP-UX Version 1.6.0 Release Notes First Edition (May 2011) First Edition (May 2011) This document edition applies to Version 1.6.0 of the IBM XIV Host Attachment Kit for
More informationLive Partition Mobility
Live Partition Mobility Jaqui Lynch lynchj@forsythe.com Presentation at: http://www.circle4.com/forsythe/lpm2014.pdf 1 1 Why Live Partition Mobility? LPM LIVE PARTITION MOBILITY Uses Server Consolidation
More informationHP StorageWorks 4000/6000/8000 Enterprise Virtual Array connectivity for Sun Solaris installation and reference guide
HP StorageWorks 4000/6000/8000 Enterprise Virtual Array connectivity for Sun Solaris installation and reference guide Part number: 5697-5263 First edition: May 2005 Legal and notice information Copyright
More informationVeritas Storage Foundation and High Availability Solutions Microsoft Clustering Solutions Guide for Microsoft SQL 2008
Veritas Storage Foundation and High Availability Solutions Microsoft Clustering Solutions Guide for Microsoft SQL 2008 Windows Server 2003 Windows Server 2008 5.1 Application Pack 1 Veritas Storage Foundation
More informationCluster Server Generic Application Agent Configuration Guide - AIX, Linux, Solaris
Cluster Server 7.3.1 Generic Application Agent Configuration Guide - AIX, Linux, Solaris Last updated: 2017-11-04 Legal Notice Copyright 2017 Veritas Technologies LLC. All rights reserved. Veritas and
More informationHitachi Dynamic Link Manager (for AIX) Release Notes
Hitachi Dynamic Link Manager (for AIX) 8.1.4-00 Release Notes Contents About this document... 1 Intended audience... 1 Getting help... 2 About this release... 2 Product package contents... 2 New features
More informationORACLE SOLARIS CLUSTER INTEROPERABILITY MATRIX
ORACLE SOLARIS CLUSTER INTEROPERABILITY MATRIX Fujitsu ETERNUS Storage Center Storage Supported ETERNUS DX100 S3, DX200 S3, DX200F, DX500 S3, DX600 S3, ETERNUS AF250, ETERNUS AF650, ETERNUS DX60, ETERNUS
More informationExpert Reference Series of White Papers. Understanding the AIX Object Data Manager
Expert Reference Series of White Papers Understanding the AIX Object Data Manager 1-800-COURSES www.globalknowledge.com Understanding the AIX Object Data Manager Iain Campbell, UNIX/Linux Open Systems
More informationAIX Logical Volume Manager from A to Z: Troubleshooting and Commands
AIX Logical Volume Manager from A to Z: Troubleshooting and Commands Laurent Vanel, Ronald van der Knaap, Dugald Foreman, Keigo Matsubara, Antony Steel International Technical Support Organization www.redbooks.ibm.com
More informationSymmetrix Fibre Channel with Qlogic Host Bus Adapters in the SCO UnixWare 7 Environment
Symmetrix Fibre Channel with Qlogic Host Bus Adapters in the SCO UnixWare 7 Environment November 2000 Copyright 2000 EMC Corporation. All rights reserved. No part of this publication may be reproduced
More informationVeritas Storage Foundation and High Availability Solutions Application Note: Support for HP-UX Integrity Virtual Machines
Veritas Storage Foundation and High Availability Solutions Application Note: Support for HP-UX Integrity Virtual Machines HP-UX 11i v3 5.0.1 Veritas Storage Foundation and High Availability Solutions Application
More informationNetBackup SAN Client and Fibre Transport Troubleshooting Guide. 2 What are the components of the SAN Client feature?
Symantec TechNote 288437 NetBackup SAN Client and Fibre Transport Troubleshooting Guide 1 Introduction Revision F This document explains how to troubleshoot different failures that may occur while using
More informationDell EMC Unity Family
Dell EMC Unity Family Version 4.2 Configuring Hosts to Access Fibre Channel (FC) or iscsi Storage 302-002-568 REV 03 Copyright 2016-2017 Dell Inc. or its subsidiaries. All rights reserved. Published July
More information