Configuration Guide -Server Connection-

Size: px
Start display at page:

Download "Configuration Guide -Server Connection-"

Transcription

1 FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for VMware ESX

2 This page is intentionally left blank.

3 Preface This manual briefly explains the operations that need to be performed by the user in order to connect an ETERNUS DX/AF to a server running VMware ESX via a Fibre Channel interface. This manual should be used in conjunction with any other applicable user manuals, such as those for the ETERNUS DX/AF, server, OS, Fibre Channel cards, and drivers. Refer to "Configuration Guide -Server Connection- Notations" for the notations used in this manual such as product trademarks and product names. For storage systems that are supported by the OS, refer to the Server Support Matrix of the ETERNUS DX/AF. 28th Edition April 2018 The Contents and Structure of this Manual This manual is composed of the following 12 chapters. "Chapter 1 Workflow" (page 6) This chapter describes how to connect the ETERNUS DX/AF storage systems to a server running VMware ESX. "Chapter 2 Checking the Server Environment" (page 9) This chapter describes which servers can be connected to ETERNUS DX/AF storage systems. "Chapter 3 Notes" (page 11) This chapter describes issues that should be noted when connecting the ETERNUS DX/AF storage systems and server. "Chapter 4 Installing and Setting Up ETERNUSmgr" (page 16) This chapter describes how to install ETERNUSmgr. "Chapter 5 Setting Up the ETERNUS DX/AF" (page 17) This chapter describes how to set up an ETERNUS DX/AF. "Chapter 6 Setting Up the Fibre Channel Switches" (page 18) This chapter describes how to set up the Fibre Channel switches. "Chapter 7 Setting Up the VMware ESX Server" (page 20) This chapter describes how to set up the VMware ESX server. "Chapter 8 For VMware vsphere" (page 21) This chapter describes how to set up for use with VMware vsphere. "Chapter 9 Virtual Machine" (page 51) This chapter describes how to operate the Virtual Machine. "Chapter 10 Dynamic Recognition of LUNs Added While VMware ESX is in Use" (page 53) This chapter describes dynamic recognition of LUNs added while VMware ESX is in use. "Chapter 11 Storage Migration" (page 54) This chapter describes the procedures that are related to Storage Migration. "Chapter 12 Non-disruptive Storage Migration" (page 59) This chapter describes the procedures that are related to Non-disruptive Storage Migration. 3

4 Table of Contents Chapter 1 Workflow 6 Chapter 2 Checking the Server Environment Hardware Fibre Channel Cards Connection Compatibility of ETERNUS DX/AF Storage Systems to VMware ESX Virtual Machine Chapter 3 Notes Connection Notes VMware ESX Operating Notes ETERNUS DX/AF Setup Notes SAN Boot Notes ETERNUS DX/AF to VMware VCB Proxy Server (on Windows ) Connection Notes Server Startup and Power Supply Control Notes Notes on WWN Instance Management Table for the Server System Design Sheet Notes VMware Multipath Plug-in Notes on Installing the Storage Cluster Function VMware vsphere Virtual Volumes (VVOL) Notes Chapter 4 Installing and Setting Up ETERNUSmgr 16 Chapter 5 Setting Up the ETERNUS DX/AF 17 Chapter 6 Setting Up the Fibre Channel Switches 18 Chapter 7 Setting Up the VMware ESX Server 20 Chapter 8 For VMware vsphere Checking the LUNs

5 Table of Contents Turning On the Devices Checking the Connected Devices Enabling ALUA Checking the LUNs Checking the Active Paths Checking the Active Path for a Single-Path Configuration Checking the Active Path for a Multi-Path Configuration Setting Up the Volumes For VMware vsphere 6.0 or later For VMware vsphere 5.5 or earlier Checking the Maximum Command Queue Depth of the Fibre Channel Card Changing the Maximum Outstanding Disk Requests for Virtual Machines For VMware vsphere 6.0 or later For VMware vsphere For VMware vsphere 5.1 or Earlier Plug-in Settings Changing the Multipath Operation Chapter 9 Virtual Machine For Windows Checking the Registry Information Notes for Configuring Windows Server Failover Clustering For Linux Applying Virtual Machine Updates...52 Chapter 10 Dynamic Recognition of LUNs Added While VMware ESX is in Use 53 Chapter 11 Storage Migration 54 Chapter 12 Non-disruptive Storage Migration 59 5

6 Chapter 1 Workflow This chapter describes how to connect the ETERNUS DX/AF storage systems to a server running VMware ESX. This manual explains how to perform various operations not referenced in other documents. Required Documents "Server Support Matrix" "Server Support Matrix for FC-SWITCH" "Configuration Guide -Server Connection- Storage System Settings" that corresponds to the ETERNUS DX/AF to be connected "Configuration Guide -Server Connection- (Fibre Channel) Fibre Channel Switch Settings" "Configuration Guide -Server Connection- (Fibre Channel) for VMware ESX Driver Settings for Fujitsu Fibre Channel Cards" "Configuration Guide -Server Connection- (Fibre Channel) for VMware ESX Driver Settings for Non-Fujitsu Fibre Channel Cards" "ETERNUS Web GUI User's Guide" "ETERNUSmgr Install Guide" "ETERNUSmgr User Guide" Manuals supplied with the Fibre Channel card and software Workflow Installing ETERNUSmgr and Setting Up the ETERNUS DX/AF If ETERNUSmgr is to be used, install it and set up the ETERNUS DX/AF. "Chapter 4 Installing and Setting Up ETERNUSmgr" (page 16) "Chapter 5 Setting Up the ETERNUS DX/AF" (page 17) Checking the setup and maintenance operations - "ETERNUS Web GUI User's Guide" Installing ETERNUSmgr - "ETERNUSmgr Install Guide" Checking the ETERNUSmgr operational procedures - "ETERNUSmgr User Guide" Setting up the ETERNUS DX/AF - "Configuration Guide -Server Connection- Storage System Settings" that corresponds to the ETER- NUS DX/AF to be connected 6

7 Chapter 1 Workflow Setting Up the Fibre Channel Switches If a Fibre Channel switch is to be used, set it up now. "Chapter 6 Setting Up the Fibre Channel Switches" (page 18) Setting up the Fibre Channel switches - "Configuration Guide -Server Connection- (Fibre Channel) Fibre Channel Switch Settings" Checking the Fibre Channel switch connection requirements - "Server Support Matrix for FC-SWITCH" Setting Up the VMware ESX Server Install the Fibre Channel card in the server, then identify and record the Fibre Channel card details. For a SAN Boot configuration, also perform the SAN Boot settings. "Chapter 7 Setting Up the VMware ESX Server" (page 20) Setting up the VMware ESX server, SAN Boot, and Fibre Channel card BIOS - "Configuration Guide -Server Connection- (Fibre Channel) for VMware ESX Driver Settings for Fujitsu Fibre Channel Cards" - "Configuration Guide -Server Connection- (Fibre Channel) for VMware ESX Driver Settings for Non- Fujitsu Fibre Channel Cards" Checking the Fibre Channel card driver versions - "Server Support Matrix" Checking the LUNs Confirm the VMware ESX LUNs (logical units). For VMware vsphere - "8.1 Checking the LUNs" (page 21) Checking the Active Paths Confirm the VMware ESX path(s). For VMware vsphere - "8.2 Checking the Active Paths" (page 27) 7

8 Chapter 1 Workflow Creating the Volumes Create the VMware ESX volumes. For VMware vsphere - "8.3 Setting Up the Volumes" (page 40) For VMware 6.0 or later For VMware 5.5 or earlier Checking the Maximum Command Queue Depth of the Fibre Channel Card Check the maximum command queue depth of the Fibre Channel card. "8.4 Checking the Maximum Command Queue Depth of the Fibre Channel Card" (page 45) Changing the Maximum Outstanding Disk Requests for Virtual Machines Change the Maximum Outstanding Disk Requests for virtual machines. "8.5 Changing the Maximum Outstanding Disk Requests for Virtual Machines " (page 46) When a VMware multipath plug-in is used Setting Up the Plug-in Set the VMware multipath plug-in. For VMware vsphere - "8.6 Plug-in Settings" (page 50) Starting the Virtual Machine Notes on Virtual Machine operation and related settings are given in this manual and other documents. "Chapter 9 Virtual Machine" (page 51) 8

9 Chapter 2 Checking the Server Environment Connection to servers is possible in the following environments. Check the "Server Support Matrix" for server environment conditions. 2.1 Hardware VMware ESX connection may require the use of Fibre Channel switches, depending on the version of VMware ESX used. Fibre Channel switches that can be connected to the ETERNUS DX/AF vary depending on the connection environment (OS or the ETERNUS DX/AF). Refer to "Server Support Matrix for FC-SWITCH" to check the available Fibre Channel switches in advance. Access the following documents or use the "Server Support Matrix" to determine which models are compatible with which servers. - Search the VMware Compatibility Guide ETERNUS DX/AF storage systems support SAN Boot. For SAN Boot details, refer to "3.4 SAN Boot Notes" (page 13). VMware ESX may be SAN Booted if a SAN Boot capable Fibre Channel card is used. For more details of VMware ESX SAN Booting, refer to the following web-site and documents: - Reference URL: - Reference documents: "VMware vsphere Documentation: vsphere Storage Guide" "VMware vsphere 4 Documentation: Fibre Channel SAN Configuration Guide" 2.2 Fibre Channel Cards Refer to the "Server Support Matrix". 9

10 Chapter 2 Checking the Server Environment 2.3 Connection Compatibility of ETERNUS DX/AF Storage Systems to VMware ESX 2.3 Connection Compatibility of ETERNUS DX/AF Storage Systems to VMware ESX Access the following web-site to check which ETERNUS DX/AF models may be connected to VMware ESX: Search the VMware Compatibility Guide Virtual Machine Virtual Machine is a virtual machine created on the VMware ESX server. Details of how to install an OS on the VMware ESX Virtual Machine may be checked via the following URL: 10

11 Chapter 3 Notes Note the following issues when connecting the ETERNUS DX/AF to a server. 3.1 Connection Notes To ensure reliable access to the ETERNUS DX/AF storage systems, the following methods are recommended: - Connection via multiple paths - Balancing of active paths - VMware multipath plug-in VMware multipath plug-in VMware ESX HBA#1 Cable HBA#2 Example configuration with optimized load balancing of the LUNs SN200#1 Fibre Channel switch Cable SN200#2 Fibre Channel switch CM#0 CA#0 Port#0 CM#1 CA#0 Port#0 Active path#1 (to LUN0) LUN0 LUN1 Active path#2 (to LUN1) Setting up multiple access paths between the server and the ETERNUS DX/AF creates a multipath configuration. A multipath configuration provides improved access redundancy. For VMware multipath plug-in details, refer to "3.9 VMware Multipath Plug-in" (page 14). The recommended "Path Selection Policy" setting is as follows: For VMware vsphere "RoundRobin (VMware)" 11

12 Chapter 3 Notes 3.2 VMware ESX Operating Notes However, when Windows Server Failover Clustering is used in virtual machines and VMware vsphere 5.1 Update 2 or earlier is used, set to "Most Recently Used (MRU)". For more details, refer to the VMware web-site for KB It is recommended that system design sheets be drawn up. When deciding the access paths for the multipath function, first design a load balanced system, and then create the corresponding system design sheets. Even if settings and connections are made according to the "Configuration Guide -Server Connection-", confirmation of LUN might not be possible. Set the transfer speed for the FC switch port to a fixed value based on the maximum transfer speed for the server's Fibre Channel card or the maximum transfer speed of the storage system CA port. 3.2 VMware ESX Operating Notes Refer to the following web-site for the number of LUNs that VMware ESX can recognize. When Windows is used on the Virtual Machine, the registry will need to be modified after Windows is installed. For details, refer to "Chapter 9 Virtual Machine" (page 51). The VMware ESX's multipath function supports path failover, meaning that server access can continue unaffected by any problems that might arise in the Fibre Channel cables or switches. It should be noted that path failover can fail to occur when multiple SCSI sense codes are repeatedly and simultaneously received. ETERNUS Multipath Driver and GR Multipath Driver do not need to be installed on a VMware ESX Virtual Machine. The multipath function of VMware ESX provides path redundancy. 3.3 ETERNUS DX/AF Setup Notes When connecting a VMware ESX server to the ETERNUS DX/AF, check that the firmware version is as specified in the "Server Support Matrix". When LUN groups (Affinity Groups) are configured for each of the physical servers in a configuration where the physical servers share LUNs (such as in a vmotion configuration), a LUN group (Affinity Group) mapping should be used to ensure that each shared LUN is assigned the same LUN number across every physical server. When connecting to VMware ESX with multiple paths that are sharing a single LUN, the Reset Group setting may need to be changed from the default value for some ETERNUS DX/AF models. Follow the instructions that are provided in "Configuration Guide -Server Connection- Storage System Settings" that corresponds to the ETERNUS DX/AF to be connected. When adding LUNs while VMware ESX is in use (recognizing LUNs dynamically), refer to "Chapter 10 Dynamic Recognition of LUNs Added While VMware ESX is in Use" (page 53). 12

13 Chapter 3 Notes 3.4 SAN Boot Notes 3.4 SAN Boot Notes All ETERNUS DX/AF storage systems support SAN Boot. VMware ESX calls SAN Boot to "Boot From a SAN". "Boot From a SAN" means to boot the VMware ESX server from a Storage Area Network (SAN). Only set SAN Boot for supported Fibre Channel cards. For the Fibre Channel card settings, refer to "Configuration Guide -Server Connection- (Fibre Channel) for VMware ESX" for the Fibre Channel cards to be used. 3.5 ETERNUS DX/AF to VMware VCB Proxy Server (on Windows ) Connection Notes When connecting a Windows -based VMware VCB (VMware Consolidated Backup) Proxy server to an ETER- NUS DX60 S2, the VMware ESX shares the LUNs, and the ETERNUS DX60 S2 settings must be adjusted. For details of the settings, refer to "Configuration Guide -Server Connection- Storage System Settings" that corresponds to the ETERNUS DX/AF to be connected. 3.6 Server Startup and Power Supply Control Notes Before turning the server on, check that the ETERNUS DX/AF storage systems and Fibre Channel switches are all "Ready". If the server is turned on and they are not "Ready", the server will not be able to recognize the ETERNUS DX/AF storage systems. Also, when the ETERNUS DX/AF power supply is being controlled by a connected server, make sure that the ETERNUS DX/AF does not shut down before the connected servers. Similarly, the Fibre Channel switches must also be turned off after the connected servers have been shut down. If turned off, data writes from the running server cannot be saved to the ETERNUS DX/AF storage systems, and already saved data may also be affected. 3.7 Notes on WWN Instance Management Table for the Server The WWN instance management table for the server is a worksheet that helps make the process of installing an ETERNUS DX/AF easy. It is important that the system details be recorded after first installing the system and also each time the system is subsequently modified, expanded, or has maintenance work performed on it. Creating an instance management table makes installation and maintenance of the system easy. Use template instance management tables provided in "Appendix Various Management Tables (Template)" of the "Configuration Guide - Server Connection- (Fibre Channel) for Windows Driver Settings" for the Fibre Channel card being used. 13

14 Chapter 3 Notes 3.8 System Design Sheet Notes 3.8 System Design Sheet Notes The system design sheet is a spreadsheet program work sheet that is used to simplify the process of installing the ETERNUS DX/AF. It is important that the system details be recorded after first installing the system and also each time the system is subsequently modified, expanded, or has maintenance work performed on it. Creating a system design sheet makes installation and maintenance of the system easy. 3.9 VMware Multipath Plug-in For improved system reliability, installing the VMware multipath plug-in for the ETERNUS DX/AF is recommended. The VMware multipath plug-in for the ETERNUS DX/AF can prevent access from being stopped when a path fails by optimizing the VMware multipath's path fail-over function for the ETERNUS DX/AF. For setting details, refer to "8.6 Plug-in Settings" (page 50). For details on how to obtain VMware Multi-Pathing plug-in for ETERNUS, contact your sales representative Notes on Installing the Storage Cluster Function To install the Storage Cluster function, rebooting the server is necessary after the TFO group is set up VMware vsphere Virtual Volumes (VVOL) Notes In a VVOL environment, RHEL 6.4 may become unable to mount its swap space. As a result, the swap space mounting process during the virtual machine startup becomes stagnated and prevents RHEL 6.4 from booting. Event Cause This problem always occurs when all of the following conditions are met. The ETERNUS DX S4/S3 series or the ETERNUS AF series is used with firmware version V10L70 or later and earlier than V10L80 The connected server is running VMware vsphere 6.5 and is configured with a VVOL environment The virtual machine hardware version is 13 The OS of the virtual machine is RHEL 6.4 The swap space is created in a physical volume (*1) using the RHEL6.4 side settings Example: /dev/sda1 g /boot /dev/sda2 g /swap *1: The swap space is created in the LVM volume during a default installation, so this problem does not occur. 14

15 Chapter 3 Notes 3.11 VMware vsphere Virtual Volumes (VVOL) Notes Coping Method If a different firmware version can be applied to the ETERNUS DX S4/S3 series or the ETERNUS AF series Apply firmware version V10L80 or later. If a different firmware version cannot be applied to the ETERNUS DX S4/S3 series or the ETERNUS AF series The system administrator must perform one of the following operations and then restart the virtual machine. - Change the virtual machine hardware version to a version other than 13 - Update RHEL Create a swap space in the LVM logical volume - Change the virtual machine environment from a VVOL environment to a VMFS environment 15

16 Chapter 4 Installing and Setting Up ETERNUSmgr If ETERNUSmgr is to be used, install it according to the directions given in the "ETERNUSmgr Install Guide". After installation is complete, follow the instructions in "ETERNUSmgr User Guide" and set up ETERNUSmgr. 16

17 Chapter 5 Setting Up the ETERNUS DX/AF Set up the ETERNUS DX/AF storage systems using ETERNUS Web GUI or ETERNUSmgr. ETERNUS DX/AF setup can be performed independently of server setup. For details on how to perform these settings, refer to the following manuals. "Configuration Guide -Server Connection- Storage System Settings" that corresponds to the ETERNUS DX/AF to be connected "ETERNUS Web GUI User's Guide" or "ETERNUSmgr User Guide" 17

18 Chapter 6 Setting Up the Fibre Channel Switches Perform the settings required to connect the ETERNUS DX/AF storage systems and server via the Fibre Channel switch, according to "Configuration Guide -Server Connection- (Fibre Channel) Fibre Channel Switch Settings". If the access path is set with ETERNUS SF Storage Cruiser, the Host Response settings are set to the default values. If the Host Response settings are changed from the default values, set the Host Response again. The following examples show configurations in which a server is connected to a Fibre Channel switch with zoning. The following example shows a configuration in which multiple servers are connected to multiple CAs. Name : Server#1 Name : Server#2 Port0 Port1 Port0 Port1 ZONE1 ZONE2 ZONE3 ZONE4 Port0 Port2 Port4 Port6 Port0 Port2 Port4 Port6 FC switch FC switch Port1 Port3 Port5 Port7 Port1 Port3 Port5 Port7 Port0 Port1 Port0 Port1 Cascading line CM0 CM1 Name : RAID#1 ETERNUS DX/AF 18

19 Chapter 6 Setting Up the Fibre Channel Switches The following example shows a configuration in which a single server is connected to multiple CAs. Server Port0 Port1 ZONE1 ZONE3 ZONE4 ZONE2 Port0 Port2 Port4 Port6 Port0 Port2 Port4 Port6 FC switch FC switch Port1 Port3 Port5 Port7 Port1 Port3 Port5 Port7 Port0 Port1 Port0 Port1 Cascading line CM0 CM1 ETERNUS DX/AF 19

20 Chapter 7 Setting Up the VMware ESX Server Set up the VMware ESX server as detailed in the "Configuration Guide -Server Connection- (Fibre Channel) for VMware ESX" for the Fiber Channel card being used. "Configuration Guide -Server Connection- (Fibre Channel) for VMware ESX Driver Settings for Fujitsu Fibre Channel Cards" "Configuration Guide -Server Connection- (Fibre Channel) for VMware ESX Driver Settings for Non-Fujitsu Fibre Channel Cards" 20

21 Chapter 8 For VMware vsphere 8.1 Checking the LUNs This section describes how to check LUNs Turning On the Devices To turn on the connected devices, use the following procedure: 1 Turn on the Fibre Channel switch power (if used). 2 Check that the Ready LED (or equivalent) is lit on the Fibre Channel switch. 3 Turn on the ETERNUS DX/AF. 4 Check that the Ready LED is lit on the ETERNUS DX/AF. 5 Turn on the server Checking the Connected Devices Check the state of the connection between the server and ETERNUS DX/AF storage systems. Use the vsphere Web Client or the vsphere Client to check that the LUNs of the ETERNUS DX/AF storage systems are recognized by the server. For details on how to check the connected devices, refer to the Installation and Setup Guide at the following URL: Reference URL: 21

22 Chapter 8 For VMware vsphere 8.1 Checking the LUNs Enabling ALUA This procedure is only required when VMware vsphere contains VMware ESX 4.0/VMware ESXi 4.0. It does not need to be performed when VMware vsphere contains VMware ESX 4.0 Update 1/VMware ESXi 4.0 Update 1 or later versions. In this case, proceed to "8.1.4 Checking the LUNs" (page 24). After the VMware ESX server has been installed, Asymmetric Logical Unit Access (ALUA) should be enabled according to the following procedure. 1 Use the terminal to log in to VMware ESX as "root". 2 Execute the following command in the terminal: When connecting to an ETERNUS DX60 S2/DX80 S2/DX90 S2 esxcli nmp satp addrule --satp="vmw_satp_alua" --vendor="fujitsu" --model="ete RNUS_DXL" --description="eternus DXL with ALUA" --claim-option tpgs_on When connecting to an ETERNUS DX400 S2 series esxcli nmp satp addrule --satp="vmw_satp_alua" --vendor="fujitsu" --model="ete RNUS_DX400" --description="eternus DX400 with ALUA" --claim-option tpgs_on When connecting to an ETERNUS DX8000 S2 series esxcli nmp satp addrule --satp="vmw_satp_alua" --vendor="fujitsu" --model="ete RNUS_DX8000" --description="eternus DX8000 with ALUA" --claim-option tpgs_on 3 Execute the following command in the terminal: esxcli corestorage claiming unclaim --type location Ignore the following error message if it appears when the preceding command is executed: Errors: Unable to perform unclaim. Error message was : Unable to unclaim paths. Busy or in use devices detected. See VMkernel logs for more information. 22

23 Chapter 8 For VMware vsphere 8.1 Checking the LUNs 4 Execute the following command in the terminal: esxcli corestorage claimrule run 5 Check that the connected ETERNUS DX/AF is shown when the appropriate command is executed in the terminal: esxcli nmp satp listrules --satp VMW_SATP_ALUA When connecting to an ETERNUS DX60 S2/DX80 S2/DX90 S2 VMW_SATP_ALUA FUJITSU ETERNUS_DXL tpgs_on ETERNUS DXL with ALUA When connecting to an ETERNUS DX400 S2 series VMW_SATP_ALUA FUJITSU ETERNUS_DX400 tpgs_on ETERNUS DX400 with ALUA When connecting to an ETERNUS DX8000 S2 series VMW_SATP_ALUA FUJITSU ETERNUS_DX8000 tpgs_on ETERNUS DX8000 with ALUA 6 Log out of the terminal, and restart the VMware ESX server. Refer to the following for details of the above commands: Reference URL: Reference documents: "vsphere Command-Line Interface Concepts and Examples" 23

24 Chapter 8 For VMware vsphere 8.1 Checking the LUNs Checking the LUNs The following procedure describes how to check LUN recognitions using the vsphere Web Client or the vsphere Client For VMware vsphere 6.0 or later Log in to VMware ESX from the vsphere Web Client, and then check whether the ETERNUS DX/AF LUNs are recognized. The procedure is as follows: 1 Log in to the vsphere Web Client and select in order, [Hosts and Clusters] > target host. 2 Select in order, the [Manage] tab > [Storage] > [Storage Adapters]. 3 Select [Rescan...]. After selecting [Rescan...], the VMware ESX should attempt to recognize the ETERNUS DX/AF storage systems' LUNs again. 4 Select the virtual HBA (vmhba3 in this example) for the Fibre Channel card from the [Storage Adapters] area. The recognized devices will be shown in the [Adapter Details] area, as follows. 24

25 Chapter 8 For VMware vsphere 8.1 Checking the LUNs 5 In [Storage Devices], check [Path Selection Policy] for all the LUNs in the ETERNUS DX/AF. When the VMware ESX server recognizes the LUNs, the active path for each LUN is automatically set. Even though [Path Selection Policy] is set to [Most Recently Used (VMware)], changing the [Path Selection Policy] for all the LUNs to [Round Robin (VMware)] is recommended. The vsphere command line can also be used to change the [Path Selection Policy] settings. For more details, refer to the VMware web-site for KB If a modification method for the relevant version is not described, modify the setting with the ESXi 5.x method For VMware vsphere 5.5 or earlier Log in to VMware ESX from the vsphere Client, and then check whether the ETERNUS DX/AF LUNs are recognized. The procedure is as follows: 1 Use the vsphere Client to log in to VMware ESX as "root". 2 Select the [Configuration] tab. 3 Select [Storage Adapters] from the [Hardware] list. 4 Select [Rescan...]. 25

26 Chapter 8 For VMware vsphere 8.1 Checking the LUNs After selecting [Rescan...], the VMware ESX should attempt to recognize the ETERNUS DX/AF storage systems' LUNs again. 5 Select the virtual HBA (vmhba3 in this example) for the Fibre Channel card from the [Storage Adapters] area. The recognized devices will be shown in the [Details] area, as follows. 6 Connect to the VMware ESX server via the vsphere Client and check [Path Selection] for all the LUNs in the ETERNUS DX/AF. When the VMware ESX server recognizes the LUNs, the active path for each LUN is automatically set. Even though [Path Selection] is set to [Most Recently Used (VMware)], changing the [Path Selection] for all the LUNs to [Round Robin (VMware)] is recommended. 26

27 Chapter 8 For VMware vsphere 8.2 Checking the Active Paths The vsphere command line can also be used to change the [Path Selection Policy] settings. For more details, refer to the VMware web-site for KB If a modification method for the relevant version is not described, modify the setting with the ESXi 5.x method. 8.2 Checking the Active Paths Checking the Active Path for a Single-Path Configuration The following example configuration is used to describe how to check and set an active path with the vsphere Web Client or the vsphere Client. HBA#1 VMware ESX SN200#1 (Fibre Channel Switch) CM#0 CA#0 Port#0 CM#1 CA#0 Port#0 Active Path RAID Group#0 : LUN0 RAID Group#1 : LUN1 Outline of checking and setting the active path is as follows: 1. Check the WWN of HBA#1. 2. Check the WWN of CM#0 CA#0 Port#0. 3. Check the connection of HBA#1 and CM#0 CA#0 Port#0 with the WWN. The procedure is as follows: 27

28 Chapter 8 For VMware vsphere 8.2 Checking the Active Paths For VMware vsphere 6.0 or later 1 Log in to the vsphere Web Client and select in order, [Hosts and Clusters] > target host. 2 Select in order, the [Manage] tab > [Storage] > [Storage Adapters]. 3 Select the virtual HBA (vmhba3 in this example) for the Fibre Channel card from the [Storage Adapters] area. The recognized devices will be shown in the [Adapter Details] area, as follows. 28

29 Chapter 8 For VMware vsphere 8.2 Checking the Active Paths 4 Click the virtual device (FUJITSU Fibre Channel Disk [naa e00d ] in this example) in the [Adapter Details] area. 5 Check the WWNs of the ETERNUS DX/AF storage systems' CA ports that are connected with the Fibre Channel cards. The following connection would be displayed for the current configuration example: HBA#1 to ETERNUS DX/AF CM#0 CA#0 Port#0 29

30 Chapter 8 For VMware vsphere 8.2 Checking the Active Paths For VMware vsphere 5.5 or earlier 1 Use the vsphere Client to log in to VMware ESX as "root". 2 Select the [Configuration] tab. 3 Select [Storage Adapters] from the [Hardware] list. 4 Select the virtual HBA (vmhba3 in this example) for the Fibre Channel card from the [Storage Adapters] area. The recognized devices will be shown in the [Details] area, as follows. 5 Select and right-click the virtual device (vmhba3:c0:t0:l21 in this example) in the [Details] area. Select [Manage Paths] from the pop-up menu. 30

31 Chapter 8 For VMware vsphere 8.2 Checking the Active Paths 6 Check the WWNs of the ETERNUS DX/AF storage systems' CA ports that are connected with the Fibre Channel cards. The following connection would be displayed for the current configuration example: HBA#1 to ETERNUS DX/AF CM#0 CA#0 Port# Checking the Active Path for a Multi-Path Configuration The active path for each LUN is automatically set. The following procedure describes how to check the active paths For VMware vsphere 6.0 or later 1 Log in to the vsphere Web Client and select in order, [Hosts and Clusters] > target host. 2 Select in order, the [Manage] tab > [Storage] > [Storage Adapters]. 31

32 Chapter 8 For VMware vsphere 8.2 Checking the Active Paths 3 Select the virtual HBA (vmhba3 in this example) for the Fibre Channel card from the [Storage Adapters] area. The recognized devices will be shown in the [Adapter Details] area, as follows. 4 Click the virtual device (FUJITSU Fibre Channel Disk [naa e00d ] in this example) in the [Adapter Details] area. 32

33 Chapter 8 For VMware vsphere 8.2 Checking the Active Paths 5 Check the WWNs of the ETERNUS DX/AF storage systems' CA ports that are connected with the Fibre Channel cards. The following connection would be displayed for the current configuration example: RAID Group#0:LUN0 has the following access paths: - HBA#1 to ETERNUS DX/AF CM#0 CA#0 Port#0 - HBA#2 to ETERNUS DX/AF CM#1 CA#0 Port#0 RAID Group#1:LUN1 has the following access paths: - HBA#1 to ETERNUS DX/AF CM#0 CA#0 Port#0 - HBA#2 to ETERNUS DX/AF CM#1 CA#0 Port#0 33

34 Chapter 8 For VMware vsphere 8.2 Checking the Active Paths 6 Check the active path for each virtual device. When [Path Selection Policy] is [Most Recently Used (VMware)] In this example, it can be confirmed that the operating paths for RAID Group#0:LUN0 and RAID Group#1:LUN1 are as follows. - RAID Group#0:LUN0 ETERNUS DX/AF CM#0 CA#0 Port#0 to HBA#1 is the "Active (I/O)" path ETERNUS DX/AF CM#1 CA#0 Port#0 to HBA#2 is the "Active" path RAID Group#0:LUN0 paths can be checked in the following window: - RAID Group#1:LUN1 ETERNUS DX/AF CM#0 CA#0 Port#0 to HBA#1 is the "Active" path 34

35 Chapter 8 For VMware vsphere 8.2 Checking the Active Paths ETERNUS DX/AF CM#1 CA#0 Port#0 to HBA#2 is the "Active (I/O)" path RAID Group#1:LUN1 paths can be checked in the following window: When [Path Selection Policy] is [Round Robin (VMware)] In the active path confirmation window, the active paths for 4-path configuration LUNs can be confirmed as follows: - ETERNUS DX/AF CM#0 CA#0 Port#0 to HBA#1 is the "Active (I/O)" path - ETERNUS DX/AF CM#1 CA#0 Port#0 to HBA#2 is the "Active (I/O)" path - ETERNUS DX/AF CM#0 CA#0 Port#0 to HBA#3 is the "Active (I/O)" path - ETERNUS DX/AF CM#1 CA#0 Port#0 to HBA#4 is the "Active (I/O)" path 4-path configuration LUN active paths can be checked in the following window: 35

36 Chapter 8 For VMware vsphere 8.2 Checking the Active Paths For VMware vsphere 5.5 or earlier 1 Use the vsphere Client to log in to VMware ESX as "root". 2 Select the [Configuration] tab. 3 Select [Storage Adapters] from the [Hardware] list. 4 Select the virtual HBA (vmhba3 in this example) for the Fibre Channel card from the [Storage Adapters] area. The recognized devices will be shown in the [Details] area, as follows. 36

37 Chapter 8 For VMware vsphere 8.2 Checking the Active Paths 5 Right-click the virtual device in the [Details] area and select [Manage Paths]. In this example the vmhba3:c0:t0 path status is shown: 37

38 Chapter 8 For VMware vsphere 8.2 Checking the Active Paths 6 Check the WWNs of the ETERNUS DX/AF storage systems' CA ports that are connected with the Fibre Channel cards. The following connection would be displayed for the current configuration example: RAID Group#0:LUN0 has the following access paths: - HBA#1 to ETERNUS DX/AF CM#0 CA#0 Port#0 - HBA#2 to ETERNUS DX/AF CM#1 CA#0 Port#0 RAID Group#1:LUN1 has the following access paths: - HBA#1 to ETERNUS DX/AF CM#0 CA#0 Port#0 - HBA#2 to ETERNUS DX/AF CM#1 CA#0 Port#0 7 Check the active path for each virtual device. 38

39 Chapter 8 For VMware vsphere 8.2 Checking the Active Paths When [Path Selection Policy] is [Most Recently Used (VMware)] In this example, it can be confirmed that the operating paths for RAID Group#0:LUN0 and RAID Group#1:LUN1 are as follows. - RAID Group#0:LUN0 ETERNUS DX/AF CM#0 CA#0 Port#0 to HBA#1 is the "Active (I/O)" path ETERNUS DX/AF CM#1 CA#0 Port#0 to HBA#2 is the "Active" path RAID Group#0:LUN0 paths can be checked in the following window: - RAID Group#1:LUN1 ETERNUS DX/AF CM#0 CA#0 Port#0 to HBA#1 is the "Active" path ETERNUS DX/AF CM#1 CA#0 Port#0 to HBA#2 is the "Active (I/O)" path RAID Group#1:LUN1 paths can be checked in the following window: 39

40 Chapter 8 For VMware vsphere 8.3 Setting Up the Volumes When [Path Selection Policy] is [Round Robin (VMware)] In the active path confirmation window, the active paths for 4-path configuration LUNs can be confirmed as follows: - ETERNUS DX/AF CM#0 CA#0 Port#0 to HBA#1 is the "Active (I/O)" path - ETERNUS DX/AF CM#1 CA#0 Port#0 to HBA#2 is the "Active (I/O)" path - ETERNUS DX/AF CM#0 CA#0 Port#1 to HBA#3 is the "Active (I/O)" path - ETERNUS DX/AF CM#1 CA#0 Port#1 to HBA#4 is the "Active (I/O)" path 4-path configuration LUN active paths can be checked in the following window: 8.3 Setting Up the Volumes Start the VMware ESX. The following ETERNUS DX/AF connection example describes how to create a volume (VMFS) For VMware vsphere 6.0 or later 1 Log in to the vsphere Web Client. 2 Select [Home] > [Storage]. 40

41 Chapter 8 For VMware vsphere 8.3 Setting Up the Volumes 3 Right-click [Datacenter] and select in order, [Storage] > [New Datastore...]. A configuration pop-up window is displayed. (1) Click the [Next] button. (2) Select [VMFS] and click the [Next] button. (3) Enter a datastore name in the [Datastore name] field, select the target LUN, and click the [Next] button. (4) Select values for the partition configuration and the maximum capacity then click the [Next] button. (5) The settings are displayed. Check them, and click the [Finish] button if they are correct. 41

42 Chapter 8 For VMware vsphere 8.3 Setting Up the Volumes A new datastore is displayed under [Datacenter]. 4 To check or change the settings of the created volume, select in order, the datastore's [Manage] tab > [Settings] > [General] For VMware vsphere 5.5 or earlier 1 Use the vsphere Client to log in to VMware ESX as "root". 2 Select the [Configuration] tab. 3 Select [Storage] from the [Hardware] list. 4 Select the [Add Storage...] function in the [Storage] area. 5 Select [Disk/LUN] and click the [Next] button. 42

43 Chapter 8 For VMware vsphere 8.3 Setting Up the Volumes 6 Select the desired LUN and click the [Next] button. Device information is displayed. 7 Enter the datastore name and click the [Next] button. 43

44 Chapter 8 For VMware vsphere 8.3 Setting Up the Volumes 8 Select the [Maximum file size] and click the [Next] button. 9 The settings are displayed. Check them, and click the [Finish] button if they are correct. 10 Check the created volume in the [Storage] area. 11 To check or change the settings of the created volume, select the target LUN in the [Datastores] area. Click the [Properties...] link after the volume details are displayed in the [Datastore Details] area. 12 Change the settings in the [Volume Properties]. This example shows how to change the datastore name. 44

45 Chapter 8 For VMware vsphere 8.4 Checking the Maximum Command Queue Depth of the Fibre Channel Card Click the [Rename] button in the [General] area. 13 Change the datastore name and click the [OK] button. 8.4 Checking the Maximum Command Queue Depth of the Fibre Channel Card Confirm whether the configured driver parameters of the Fibre Channel card are applied to the LUN. This procedure is only required when using VMware vsphere 6.0 or later. 1 Check the Device Max Queue Depth of the LUN in the ETERNUS DX/AF that is connected with VMware ESXi. If the default driver value is specified for the Device Max Queue Depth even after the parameter was changed to the same value as the QueueDepth of the Fibre Channel card driver, the configuration may fail due to reasons such as invalid values. In that case, check the settings again. The value specified for the driver parameter and the Device Max Queue Depth may differ depending on the Fibre Channel card. 45

46 Chapter 8 For VMware vsphere 8.5 Changing the Maximum Outstanding Disk Requests for Virtual Machines Check "FUJITSU Fibre Channel Disk (naa.xxx)" and "Device Max Queue Depth" in the following example. # esxcli storage core device list grep -E '(Display Name: Device Max Queue Depth:)' Display Name: Local LSI Disk (naa a6af1560de849bc) Has Settable Display Name: true Device Max Queue Depth: 128 Display Name: FUJITSU Fibre Channel Disk (naa.6000b5d0006a a0b9f ) Has Settable Display Name: true Device Max Queue Depth: 8 Display Name: FUJITSU Fibre Channel Disk (naa.6000b5d0006a a0b9f014a0000) Has Settable Display Name: true Device Max Queue Depth: 8 Display Name: Local MATSHITA CD-ROM (mpx.vmhba32:c0:t0:l0) Has Settable Display Name: false Device Max Queue Depth: Changing the Maximum Outstanding Disk Requests for Virtual Machines Change the Maximum Outstanding Disk Requests for virtual machines to match the queue depth that is specified for the driver parameter. Only change this parameter if multiple virtual machines are installed in a LUN. Note that changing this parameter is not required when only one virtual machine is installed in a LUN or when there are no virtual machines installed in a LUN For VMware vsphere 6.0 or later 1 Check the Maximum Outstanding Disk Requests for virtual machines and the device name of the ETER- NUS DX/AF that is connected with VMware ESXi. Perform Step 2 and later steps if the Maximum Outstanding Disk Requests for virtual machines is different from the value (QueueDepth) that is specified for the driver parameter of the Fibre Channel card. Check "FUJITSU Fibre Channel Disk (naa.xxx)" and "No of outstanding IOs with competing worlds" in the following example. # esxcli storage core device list grep -E '(Display Name: No of outstanding IOs with competing worlds:)' Display Name: Local LSI Disk (naa a6af1560de849bc) Has Settable Display Name: true No of outstanding IOs with competing worlds: 32 Display Name: FUJITSU Fibre Channel Disk (naa.6000b5d0006a a0b9f ) Has Settable Display Name: true No of outstanding IOs with competing worlds: 32 Display Name: FUJITSU Fibre Channel Disk (naa.6000b5d0006a a0b9f014a0000) Has Settable Display Name: true No of outstanding IOs with competing worlds: 32 Display Name: Local MATSHITA CD-ROM (mpx.vmhba32:c0:t0:l0) Has Settable Display Name: false No of outstanding IOs with competing worlds: 32 46

47 Chapter 8 For VMware vsphere 8.5 Changing the Maximum Outstanding Disk Requests for Virtual Machines 2 Change the setting value for the Maximum Outstanding Disk Requests for virtual machines. Maximum Outstanding Disk Requests for virtual machines No of outstanding IOs with competing worlds Setting value The value (Device Max Queue Depth) that is checked in "8.4 Checking the Maximum Command Queue Depth of the Fibre Channel Card" (page 45). Use the following command to set the same value for each LUN if the Maximum Outstanding Disk Requests for virtual machines are different from the value described in this table. If the actual result exceeds the maximum value for the OS (the Maximum Outstanding Disk Requests for virtual machines in the OS specifications), use the maximum value. # esxcli storage core device set -d naa.6000b5d0006a a0b9f O 8 # esxcli storage core device set -d naa.6000b5d0006a a0b9f014a0000 -O 8 3 Reboot VMware ESXi. # reboot 4 After rebooting VMware ESXi, check the setting values. # esxcli storage core device list grep -E '(Display Name: No of outstanding IOs with competing worlds:)' Display Name: Local LSI Disk (naa a6af1560de849bc) Has Settable Display Name: true No of outstanding IOs with competing worlds: 32 Display Name: FUJITSU Fibre Channel Disk (naa.6000b5d0006a a0b9f ) Has Settable Display Name: true No of outstanding IOs with competing worlds: 8 Display Name: FUJITSU Fibre Channel Disk (naa.6000b5d0006a a0b9f014a0000) Has Settable Display Name: true No of outstanding IOs with competing worlds: 8 Display Name: Local MATSHITA CD-ROM (mpx.vmhba32:c0:t0:l0) Has Settable Display Name: false No of outstanding IOs with competing worlds: For VMware vsphere Check the Maximum Outstanding Disk Requests for virtual machines and the device name of the ETER- NUS DX/AF that is connected with VMware ESXi. Perform Step 2 and later steps if the Maximum Outstanding Disk Requests for virtual machines is different from the value (QueueDepth) that is specified for the driver parameter of the Fibre Channel card. 47

48 Chapter 8 For VMware vsphere 8.5 Changing the Maximum Outstanding Disk Requests for Virtual Machines Check "FUJITSU Fibre Channel Disk (naa.xxx)" and "No of outstanding IOs with competing worlds" in the following example. # esxcli storage core device list grep -E '(Display Name: No of outstanding IOs with competing worlds:)' Display Name: Local LSI Disk (naa a6af1560de849bc) Has Settable Display Name: true No of outstanding IOs with competing worlds: 32 Display Name: FUJITSU Fibre Channel Disk (naa.6000b5d0006a a0b9f ) Has Settable Display Name: true No of outstanding IOs with competing worlds: 32 Display Name: FUJITSU Fibre Channel Disk (naa.6000b5d0006a a0b9f014a0000) Has Settable Display Name: true No of outstanding IOs with competing worlds: 32 Display Name: Local MATSHITA CD-ROM (mpx.vmhba32:c0:t0:l0) Has Settable Display Name: false No of outstanding IOs with competing worlds: 32 2 Change the set value for the Maximum Outstanding Disk Requests for virtual machines. Maximum Outstanding Disk Requests for virtual machines No of outstanding IOs with competing worlds Setting value Value (QueueDepth) that is specified for the driver parameter of the Fibre Channel card Use the following command to set the same value for each LUN when the Maximum Outstanding Disk Requests for virtual machines are different from the QueueDepth setting for the driver parameter. If the actual result exceeds the maximum value for the OS (the Maximum Outstanding Disk Requests for virtual machines in the OS specifications), use the maximum value. # esxcli storage core device set -d naa.6000b5d0006a a0b9f O 8 # esxcli storage core device set -d naa.6000b5d0006a a0b9f014a0000 -O 8 3 Reboot VMware ESXi. # reboot 4 After rebooting VMware ESXi, check the setting values. # esxcli storage core device list grep -E '(Display Name: No of outstanding IOs with competing worlds:)' Display Name: Local LSI Disk (naa a6af1560de849bc) Has Settable Display Name: true No of outstanding IOs with competing worlds: 32 Display Name: FUJITSU Fibre Channel Disk (naa.6000b5d0006a a0b9f ) Has Settable Display Name: true No of outstanding IOs with competing worlds: 8 Display Name: FUJITSU Fibre Channel Disk (naa.6000b5d0006a a0b9f014a0000) Has Settable Display Name: true No of outstanding IOs with competing worlds: 8 Display Name: Local MATSHITA CD-ROM (mpx.vmhba32:c0:t0:l0) Has Settable Display Name: false No of outstanding IOs with competing worlds: 32 48

49 Chapter 8 For VMware vsphere 8.5 Changing the Maximum Outstanding Disk Requests for Virtual Machines For VMware vsphere 5.1 or Earlier 1 Check the Maximum Outstanding Disk Requests for virtual machines. Perform Step 2 and later steps if the Maximum Outstanding Disk Requests for virtual machines is different from the value (QueueDepth) that is specified for the driver parameter of the Fibre Channel card. # vim-cmd hostsvc/advopt/view Disk.SchedNumReqOutstanding (vim.option.optionvalue) [ (vim.option.optionvalue) { dynamictype = <unset>, key = "Disk.SchedNumReqOutstanding", value = 32, } ] 2 Change the set value for the Maximum Outstanding Disk Requests for virtual machines. Maximum Outstanding Disk Requests for virtual machines Disk.SchedNumReqOutstanding Setting value Value (QueueDepth) that is specified for the driver parameter of the Fibre Channel card Use the following command to set the same value when the Maximum Outstanding Disk Requests for virtual machines are different from the QueueDepth setting for the driver parameter. If the actual result exceeds the maximum value for the OS (the maximum outstanding disk requests in the OS specifications), use the maximum value. # vim-cmd hostsvc/advopt/update Disk.SchedNumReqOutstanding long 8 3 Reboot VMware ESXi or ESX. # reboot 4 After rebooting VMware ESXi or ESX, check the setting values. # vim-cmd hostsvc/advopt/view Disk.SchedNumReqOutstanding (vim.option.optionvalue) [ (vim.option.optionvalue) { dynamictype = <unset>, key = "Disk.SchedNumReqOutstanding", value = 8, } ] 49

50 Chapter 8 For VMware vsphere 8.6 Plug-in Settings 8.6 Plug-in Settings Set up VMware Multi-Pathing plug-in for ETERNUS by following "Software Information", which is a manual that is provided with the VMware Multi-Pathing plug-in for ETERNUS. 8.7 Changing the Multipath Operation If "VMware Multi-Pathing plug-in for ETERNUS" is not used with ESXi 6.0 or later, change the multipath operation as shown below. For more details, refer to the VMware web-site for KB Check the device name of all the LUNs in the ETERNUS DX/AF that is connected with VMware ESXi. Check "FUJITSU Fibre Channel Disk (naa.xxx)" in the following example. # esxcli storage nmp device list grep -E 'Device Display Name:' Device Display Name: Local LSI Disk (naa a6af1560de849bc) Device Display Name: FUJITSU Fibre Channel Disk (naa.6000b5d0006a a0b9f ) Device Display Name: FUJITSU Fibre Channel Disk (naa.6000b5d0006a a0b9f014a0000) Device Display Name: Local MATSHITA CD-ROM (mpx.vmhba32:c0:t0:l0) 2 Change the multipath operation. Use the following command to set parameters for all LUNs in the ETERNUS DX/AF. # esxcli storage nmp satp generic deviceconfig set -c enable_action_onretryerrors -d naa.6000b5d0006a a0b9f # esxcli storage nmp satp generic deviceconfig set -c enable_action_onretryerrors -d naa.6000b5d0006a a0b9f 014a Confirm the settings. Confirm that "action_onretryerrors=on" is included in "Storage Array Type Device Config" for the LUNs in the ETERNUS DX/AF. # esxcli storage nmp device list grep -E '(Device Display Name: Storage Array Type Device Config:)' Device Display Name: Local LSI Disk (naa a6af1560de849bc) Storage Array Type Device Config: SATP VMW_SATP_LOCAL does not support device configuration. Device Display Name: FUJITSU Fibre Channel Disk (naa.6000b5d0006a a0b9f ) Storage Array Type Device Config: {implicit_support=on; explicit_support=off; explicit_allow=on; alua_followov er=on; action_onretryerrors=on; {TPG_id=32897,TPG_state=AO}{TPG_id=32896,TPG_state=AO}{TPG_id=32913,TPG_state=ANO }{TPG_id=32912,TPG_state=ANO}} Device Display Name: FUJITSU Fibre Channel Disk (naa.6000b5d0006a a0b9f014a0000) Storage Array Type Device Config: {implicit_support=on; explicit_support=off; explicit_allow=on; alua_followov er=on; action_onretryerrors=on; {TPG_id=32897,TPG_state=AO}{TPG_id=32896,TPG_state=AO}{TPG_id=32913,TPG_state=ANO }{TPG_id=32912,TPG_state=ANO}} Device Display Name: Local MATSHITA CD-ROM (mpx.vmhba32:c0:t0:l0) Storage Array Type Device Config: SATP VMW_SATP_LOCAL does not support device configuration. 50

51 Chapter 9 Virtual Machine This chapter describes the notes on the Virtual Machine and its settings. To configure the Virtual Machine, access the following web-site and check the "Guest Operation System Installation Guide". Guest Operation System Installation Guide For Windows Checking the Registry Information Check the value of the "TimeOutValue" registry key. If the "TimeOutValue" registry key does not exist, then create it. The registry file should be backed up before creating or changing any registry values. 1 Click the [Start] button, and then click [Run]. 2 In the [Run] dialog box, type "regedit", and then click the [OK] button. Registry Editor starts. 3 Follow the path described below: \HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\Disk 4 Check the value of the "TimeOutValue" registry key. Check that the value of the "TimeOutValue" registry key is "0x3C". If the name or value is not "0x3C", change it to "0x3C". 51

52 Chapter 9 Virtual Machine 9.2 For Linux If the "TimeOutValue" key does not exist, add a registry key with the following values: The "Name" field is case-sensitive. Name Type Radix Data TimeOutValue REG_DWORD Hexadecimal 3C 5 If any registry values were added or modified, reboot the server. The modified settings will be enabled after the reboot Notes for Configuring Windows Server Failover Clustering Refer to the VMware web-site for KB and check the support guidelines before configuring Windows Server Failover Clustering. Ignore the following warning message if it appears during a verification test for Windows Server Failover Clustering: warning: Validate Storage Spaces Persistent Reservation If the verification test fails, refer to the VMware web-site for KB For Linux Applying Virtual Machine Updates This section describes notes for applying Virtual Machine updates. For the following OSs, the Virtual Machine file system may be restricted to being read-only: For details, refer to "KB51306" on the VMware web-site and apply the Virtual Machine updates. Red Hat Enterprise Linux 5 Red Hat Enterprise Linux AS v.4 Update 4 Red Hat Enterprise Linux AS v.4 Update 3 SUSE Linux Enterprise Server 10 SUSE Linux Enterprise Server 9 Service Pack 3 52

53 Chapter 10 Dynamic Recognition of LUNs Added While VMware ESX is in Use When adding LUNs while VMware ESX is in use (recognizing LUNs dynamically), first assign the added volumes to an ETERNUS DX/AF LUN group (Affinity Group), and then LUNs should be recognized with the "Rescan" operation via the VMware Infrastructure Client (Infrastructure 3), vsphere Web Client, or vsphere Client respectively described in "8.1 Checking the LUNs" (page 21). 53

54 Chapter 11 Storage Migration This chapter explains how to configure the server for performing Storage Migration. When Storage Migration is performed, configure the settings so that the ETERNUS DX/AF LUNs can be used from the server (VMware ESXi). Setting Procedure Outline Execute the operation to start Storage Migration from ETERNUS Web GUI. Perform all other operations in the server (VMware ESXi). 1 Delete the guest (VM) that is in the datastore of the LUN that is targeted for migration from the inventory. 2 Turn off the server. 3 Start Storage Migration, change the connection destination to the migration destination ETERNUS DX/AF, and then reboot the server. 4 The datastore is registered automatically. Therefore register the VM in the inventory. 5 If the LUN targeted for migration is used for Raw Device Mapping (RDM), delete the virtual hard disk and then add RDM again. 54

55 Chapter 11 Storage Migration Example Setting Procedure The following procedure shows an example configuration for VMware ESXi Delete the guest (VM) that is in the datastore of the LUN that is targeted for migration from the inventory. (1) Stop the target VM, and then right-click the target VM in vsphere Client and select "Remove from Inventory". 2 Turn off the server. 3 Start Storage Migration from ETERNUS Web GUI and then change the connection destination to the migration destination ETERNUS DX/AF and reboot the server. 55

56 Chapter 11 Storage Migration 4 The datastore is registered automatically. Therefore register the VM in the inventory. (1) Right-click the target datastore in vsphere Client, and select [Browse Datastore...]. (2) In the [Datastore Browser] window, right-click the virtual machine file (*.vmx) and select [Add to Inventory]. 56

57 Chapter 11 Storage Migration (3) Specify the registration destination for the VM in the dialog box, and then click the [Finish] button. The VM is registered in the datastore inventory. 5 If the LUN that is targeted for a migration is used for Raw Device Mapping (RDM), the virtual hard disk that was mapped using the RDM cannot be used. Therefore, delete the virtual hard disk, re-create the RDM, and then add it again. (1) Right-click the target VM in vsphere Client, and select [Edit Settings...]. (2) Confirm that the RDM virtual hard disk has a VMDK of size 0. 57

58 Chapter 11 Storage Migration (3) Delete all virtual hard disks for RDM. However, it is not necessary to delete virtual hard disks that were VMDK before any editing was performed. (4) Create RDM once again on the migration destination volume. (5) Replace all size 0 VMDK with RDM. The VM can now be started. After this procedure is completed, the datastore can be used in the migration destination ETERNUS DX/AF the same way as before the migration. 58

59 Chapter 12 Non-disruptive Storage Migration This chapter describes the procedures for connecting and disconnecting paths and provides notes for when the Non-disruptive Storage Migration function is used in the example vsphere HA environment that uses Native Multipaths and runs ESXi 5.5 Update 3. Connecting Paths The following procedure shows how to add a path to the migration destination storage system from the server (ESXi 5.5 Update 3) after the migration destination storage system is connected. 1 Check the multipath status. In the following example, the LUN consists of a two-path configuration. 2 Connect the multipath. Add the host affinity setting to the migration destination storage system. 59

60 Chapter 12 Non-disruptive Storage Migration 3 The connected multipath is recognized automatically. If recognition of the connected multipath takes a while, select the host in the vsphere Client, click [Configuration] - [Storage Adapters], and then select the relevant adapter. 4 Right-click the relevant adapter and select [Rescan]. 5 After the rescan is complete, right-click LUN in the "Details" field and select [Manage Paths]. 60

FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-

FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for VMware ESX This page is intentionally left blank. Preface This manual briefly explains the operations that need to be performed

More information

Configuration Guide -Server Connection-

Configuration Guide -Server Connection- FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Windows This page is intentionally left blank. Preface This manual briefly explains the operations that

More information

Configuration Guide -Server Connection-

Configuration Guide -Server Connection- FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Windows This page is intentionally left blank. Preface This manual briefly explains the operations that

More information

Configuration Guide -Server Connection-

Configuration Guide -Server Connection- FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Citrix XenServer This page is intentionally left blank. Preface This manual briefly explains the operations

More information

FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection-

FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (iscsi) ETERNUS DX S4/S3 series Hybrid Storage Systems, ETERNUS AF series, ETERNUS DX200F All-Flash Arrays Settings This page

More information

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

ETERNUS VAAI Plug-in for VMware vsphere User s Guide

ETERNUS VAAI Plug-in for VMware vsphere User s Guide ETERNUS VAAI Plug-in for VMware vsphere5 1.0.0 User s Guide Preface This document provides an overview of ETERNUS VAAI Plug-in for VMware vsphere5 and discribes how to use it. The Structure of this Document

More information

The Contents and Structure of this Manual. This document is composed of the following three chapters and an appendix.

The Contents and Structure of this Manual. This document is composed of the following three chapters and an appendix. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

The Contents and Structure of this Manual. This document is composed of the following six chapters and an appendix.

The Contents and Structure of this Manual. This document is composed of the following six chapters and an appendix. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-

FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Citrix XenServer This page is intentionally left blank. Preface This manual briefly explains the operations that need to be

More information

The Contents and Structure of this Manual. This document is composed of the following 12 chapters.

The Contents and Structure of this Manual. This document is composed of the following 12 chapters. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

Using EonStor DS Series iscsi-host storage systems with VMware vsphere 5.x

Using EonStor DS Series iscsi-host storage systems with VMware vsphere 5.x Using EonStor DS Series iscsi-host storage systems with VMware vsphere 5.x Application notes Abstract These application notes explain configuration details for using Infortrend EonStor DS Series iscsi-host

More information

EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA

EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA Version 4.0 Configuring Hosts to Access VMware Datastores P/N 302-002-569 REV 01 Copyright 2016 EMC Corporation. All rights reserved.

More information

FUJITSU Storage ETERNUS AF series and ETERNUS DX S4/S3 series

FUJITSU Storage ETERNUS AF series and ETERNUS DX S4/S3 series Utilizing VMware vsphere Virtual Volumes (VVOL) with the FUJITSU Storage ETERNUS AF series and ETERNUS DX S4/S3 series Reference Architecture for Virtual Platforms (15VM/iSCSI) The ETERNUS AF series and

More information

Server Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

Server Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

This guide provides configuration settings and considerations for Hosts running VMware ESXi.

This guide provides configuration settings and considerations for Hosts running VMware ESXi. The Host Server VMware ESXi Configuration Guide May 2018 This guide provides configuration settings and considerations for Hosts running VMware ESXi. Basic VMware storage administration skills are assumed

More information

Preparing the boot media/installer with the ISO file:

Preparing the boot media/installer with the ISO file: Preparing the boot media/installer with the ISO file: Download and extract the ISO file with your favorite uncompressing/extracting software (for example: 7zip or WinZip programs) to an empty USB Flash

More information

Configuration Guide -Server Connection-

Configuration Guide -Server Connection- FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (iscsi) for Windows This page is intentionally left blank. Preface This manual briefly explains the operations that need to

More information

This guide provides configuration settings and considerations for SANsymphony Hosts running VMware ESX/ESXi.

This guide provides configuration settings and considerations for SANsymphony Hosts running VMware ESX/ESXi. The Host Server VMware ESXi Configuration Guide February 2018 This guide provides configuration settings and considerations for SANsymphony Hosts running VMware ESX/ESXi. Basic VMware administration skills

More information

This guide provides configuration settings and considerations for SANsymphony Hosts running VMware ESX/ESXi.

This guide provides configuration settings and considerations for SANsymphony Hosts running VMware ESX/ESXi. The Host Server VMware ESXi Configuration Guide October 2017 This guide provides configuration settings and considerations for SANsymphony Hosts running VMware ESX/ESXi. Basic VMware administration skills

More information

Server Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

Server Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

ETERNUS Disk storage systems Server Connection Guide (FCoE) for Linux

ETERNUS Disk storage systems Server Connection Guide (FCoE) for Linux Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

Setup for Failover Clustering and Microsoft Cluster Service

Setup for Failover Clustering and Microsoft Cluster Service Setup for Failover Clustering and Microsoft Cluster Service Update 1 ESXi 5.0 vcenter Server 5.0 This document supports the version of each product listed and supports all subsequent versions until the

More information

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

Compellent Storage Center

Compellent Storage Center Compellent Storage Center Best Practices with ESX/ESXi 4.x (vsphere) Compellent Corporate Office Compellent Technologies 7625 Smetana Lane Eden Prairie, Minnesota 55344 www.compellent.com Contents Contents...

More information

Configuring and Managing Virtual Storage

Configuring and Managing Virtual Storage Configuring and Managing Virtual Storage Module 6 You Are Here Course Introduction Introduction to Virtualization Creating Virtual Machines VMware vcenter Server Configuring and Managing Virtual Networks

More information

Dell EMC SC Series Best Practices with VMware vsphere 5.x 6.x

Dell EMC SC Series Best Practices with VMware vsphere 5.x 6.x Dell EMC SC Series Best Practices with VMware vsphere 5.x 6.x Dell EMC Engineering July 2017 Dell EMC Best Practices Revisions Date Description July 2016 Initial release: combined vsphere 5.x and 6.x best

More information

The Contents and Structure of this Manual. This document is composed of the following two chapters.

The Contents and Structure of this Manual. This document is composed of the following two chapters. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200 Disk storage system to a server running Solaris, HP-UX, Windows,

More information

The Contents and Structure of this Manual. This document is composed of the following 12 chapters.

The Contents and Structure of this Manual. This document is composed of the following 12 chapters. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

EMC Performance Optimization for VMware Enabled by EMC PowerPath/VE

EMC Performance Optimization for VMware Enabled by EMC PowerPath/VE EMC Performance Optimization for VMware Enabled by EMC PowerPath/VE Applied Technology Abstract This white paper is an overview of the tested features and performance enhancing technologies of EMC PowerPath

More information

Setup for Microsoft Cluster Service Update 1 Release for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5

Setup for Microsoft Cluster Service Update 1 Release for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5 Setup for Microsoft Cluster Service Update 1 Release for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5 Setup for Microsoft Cluster Service Setup for Microsoft Cluster Service Revision: 041108

More information

The Contents and Structure of this Manual. This document is composed of the following ten chapters.

The Contents and Structure of this Manual. This document is composed of the following ten chapters. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

Multipathing Configuration for Software iscsi Using Port Binding

Multipathing Configuration for Software iscsi Using Port Binding Multipathing Configuration for Software iscsi Using Port Binding Technical WHITE PAPER Table of Contents Multipathing for Software iscsi.... 3 Configuring vmknic-based iscsi Multipathing.... 3 a) Configuring

More information

Best Practices for Implementing VMware vsphere in a Dell PS Series Storage Environment

Best Practices for Implementing VMware vsphere in a Dell PS Series Storage Environment Best Practices for Implementing VMware vsphere in a Dell PS Series Storage Environment Abstract Dell EMC recommended best practices for configuring VMware vsphere hosts connecting to Dell PS Series storage

More information

AccelStor All-Flash Array VMWare ESXi 6.0 iscsi Multipath Configuration Guide

AccelStor All-Flash Array VMWare ESXi 6.0 iscsi Multipath Configuration Guide AccelStor All-Flash Array VMWare ESXi 6.0 iscsi Multipath Configuration Guide 1 Table of Contents Introduction... 3 Prerequisites... 3 Hardware Configurations... 4 Storage... 4 VMWare ESXi Server... 4

More information

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Linux

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Linux Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

Vmware Certkiller VCP-410 Exam Bundle

Vmware Certkiller VCP-410 Exam Bundle Vmware Certkiller VCP-410 Exam Bundle Number: VCP-410 Passing Score: 700 Time Limit: 120 min File Version: 25.5 http://www.gratisexam.com/ Vmware VCP-410 Exam Bundle Exam Name: Vmware VMware Certified

More information

The Contents and Structure of this Manual. This document is composed of the following two chapters.

The Contents and Structure of this Manual. This document is composed of the following two chapters. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000 model 700, 800, 900, 1100, 1200,

More information

White Paper Effects of the Deduplication/Compression Function in Virtual Platforms ETERNUS AF series and ETERNUS DX S4/S3 series

White Paper Effects of the Deduplication/Compression Function in Virtual Platforms ETERNUS AF series and ETERNUS DX S4/S3 series White Paper Effects of the Deduplication/Compression Function in Virtual Platforms ETERNUS AF series and ETERNUS DX S4/S3 series Copyright 2017 FUJITSU LIMITED Page 1 of 17 http://www.fujitsu.com/eternus/

More information

Qsan Document - White Paper. How to configure iscsi initiator in ESXi 6.x

Qsan Document - White Paper. How to configure iscsi initiator in ESXi 6.x Qsan Document - White Paper How to configure iscsi initiator in ESXi 6.x Version 1.0 May 2015 Copyright Copyright@2004~2015, Qsan Technology, Inc. All rights reserved. No part of this document may be reproduced

More information

The Contents and Structure of this Manual. This document is composed of the following six chapters and three appendices.

The Contents and Structure of this Manual. This document is composed of the following six chapters and three appendices. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

The Contents and Structure of this Manual. This document is composed of the following three chapters.

The Contents and Structure of this Manual. This document is composed of the following three chapters. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

vsphere Storage Update 1 Modified 16 JAN 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5

vsphere Storage Update 1 Modified 16 JAN 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 Update 1 Modified 16 JAN 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have

More information

DELL POWERVAULT MD3200I / MD3600I DEPLOYMENT GUIDE FOR VMWARE ESX4.1 SERVER SOFTWARE

DELL POWERVAULT MD3200I / MD3600I DEPLOYMENT GUIDE FOR VMWARE ESX4.1 SERVER SOFTWARE DELL POWERVAULT MD3200I / MD3600I DEPLOYMENT GUIDE FOR VMWARE ESX4.1 SERVER SOFTWARE A Dell Technical White Paper Version 1.7 PowerVault MD3200i and MD3600i Storage Arrays www.dell.com/md3200i www.dell.com/md3600i

More information

Connect P300H with iscsi initiator in ESX4.0

Connect P300H with iscsi initiator in ESX4.0 Connect P300H with iscsi initiator in ESX4.0 Sam Lee Version 1.0 (OCT, 2009) - 1 - QSAN Technology, Inc. http://www.qsan.com.tw White Paper# QWP200917-P300H lntroduction In this document, it describes

More information

Server Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris

Server Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

HP 3PAR StoreServ Storage VMware ESX Host Persona Migration Guide

HP 3PAR StoreServ Storage VMware ESX Host Persona Migration Guide HP 3PAR StoreServ Storage VMware ESX Host Persona Migration Guide Abstract This guide is intended to assist customers in successfully migrating their VMware ESX/ESXi hosts on HP 3PAR StoreServ storage

More information

The Contents and Structure of this Manual. This document is composed of the following four chapters and an appendix.

The Contents and Structure of this Manual. This document is composed of the following four chapters and an appendix. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

DELL POWERVAULT MD32XXI / MD36XXI DEPLOYMENT GUIDE FOR VMWARE ESX4.1 SERVER SOFTWARE

DELL POWERVAULT MD32XXI / MD36XXI DEPLOYMENT GUIDE FOR VMWARE ESX4.1 SERVER SOFTWARE DELL POWERVAULT MD32XXI / MD36XXI DEPLOYMENT GUIDE FOR VMWARE ESX4.1 SERVER SOFTWARE A Dell Technical White Paper Version 1.5 PowerVault MD32xxi and MD36xxi Storage Arrays www.dell.com/md32xxi DISCLAIMER:

More information

PrepKing. PrepKing-VCP-410xams

PrepKing. PrepKing-VCP-410xams PrepKing Number: VCP-410 Passing Score: 700 Time Limit: 120 min File Version: 9.0 http://www.gratisexam.com/ PrepKing-VCP-410xams Sections 1. Maximum/Minimum 2. Installation 3. Management 4. Cluster 5.

More information

Server Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris

Server Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

KillTest *KIJGT 3WCNKV[ $GVVGT 5GTXKEG Q&A NZZV ]]] QORRZKYZ IUS =K ULLKX LXKK [VJGZK YKX\OIK LUX UTK _KGX

KillTest *KIJGT 3WCNKV[ $GVVGT 5GTXKEG Q&A NZZV ]]] QORRZKYZ IUS =K ULLKX LXKK [VJGZK YKX\OIK LUX UTK _KGX KillTest Q&A Exam : 3V0-622 Title : VMware Certified Advanced Professional 6 Data Center Virtualization Design Exam Version : DEMO 1 / 17 1.DRAG DROP You have been tasked with creating a vsphere 6.x data

More information

shaping tomorrow with you Eternus VVOL Matthias Bothe Fujitsu Technology Solutions

shaping tomorrow with you Eternus VVOL Matthias Bothe Fujitsu Technology Solutions shaping tomorrow with you Eternus VVOL Matthias Bothe 0 2015 Fujitsu Technology Solutions Agenda What are Virtual Volumes? Advantages of VVOLs Technical implementation of VVOL for ETERNUS Usage 1 2015

More information

VMware Exam VCP-511 VMware Certified Professional on vsphere 5 Version: 11.3 [ Total Questions: 288 ]

VMware Exam VCP-511 VMware Certified Professional on vsphere 5 Version: 11.3 [ Total Questions: 288 ] s@lm@n VMware Exam VCP-511 VMware Certified Professional on vsphere 5 Version: 11.3 [ Total Questions: 288 ] VMware VCP-511 : Practice Test Question No : 1 Click the Exhibit button. An administrator has

More information

iscsi SAN Configuration Guide

iscsi SAN Configuration Guide Update 1 ESX 4.0 ESXi 4.0 vcenter Server 4.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for

More information

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Deployment and Setup Guide for 7.1 release February 2018 215-12647_B0 doccomments@netapp.com Table of Contents

More information

Exam4Tests. Latest exam questions & answers help you to pass IT exam test easily

Exam4Tests.   Latest exam questions & answers help you to pass IT exam test easily Exam4Tests http://www.exam4tests.com Latest exam questions & answers help you to pass IT exam test easily Exam : VCP510PSE Title : VMware Certified Professional 5 - Data Center Virtualization PSE Vendor

More information

EXAM - VCP5-DCV. VMware Certified Professional 5 Data Center Virtualization (VCP5-DCV) Exam. Buy Full Product.

EXAM - VCP5-DCV. VMware Certified Professional 5 Data Center Virtualization (VCP5-DCV) Exam. Buy Full Product. VMware EXAM - VCP5-DCV VMware Certified Professional 5 Data Center Virtualization (VCP5-DCV) Exam Buy Full Product http://www.examskey.com/vcp5-dcv.html Examskey VMware VCP5-DCV exam demo product is here

More information

Dell EMC SC Series Virtual Volumes Best Practices

Dell EMC SC Series Virtual Volumes Best Practices Dell EMC SC Series Virtual Volumes Best Practices Abstract Best practices for deploying and configuring VMware vsphere Virtual Volumes with Dell EMC SC Series storage. September 2017 Dell EMC Best Practices

More information

Vmware VCP-511. VMware Certified Professional on vsphere 5 (Private Beta) Download Full Version :

Vmware VCP-511. VMware Certified Professional on vsphere 5 (Private Beta) Download Full Version : Vmware VCP-511 VMware Certified Professional on vsphere 5 (Private Beta) Download Full Version : http://killexams.com/pass4sure/exam-detail/vcp-511 in RAM. A virtual machine running completely in RAM performs

More information

Managing Multi-Hypervisor Environments with vcenter Server

Managing Multi-Hypervisor Environments with vcenter Server Managing Multi-Hypervisor Environments with vcenter Server vcenter Server 5.1 vcenter Multi-Hypervisor Manager 1.1.2 This document supports the version of each product listed and supports all subsequent

More information

Virtualization with VMware ESX and VirtualCenter SMB to Enterprise

Virtualization with VMware ESX and VirtualCenter SMB to Enterprise Virtualization with VMware ESX and VirtualCenter SMB to Enterprise This class is an intense, five-day introduction to virtualization using VMware s immensely popular Virtual Infrastructure suite including

More information

Virtualization with VMware ESX and VirtualCenter SMB to Enterprise

Virtualization with VMware ESX and VirtualCenter SMB to Enterprise Virtualization with VMware ESX and VirtualCenter SMB to Enterprise This class is an intense, four-day introduction to virtualization using VMware s immensely popular Virtual Infrastructure suite including

More information

This page is intentionally left blank.

This page is intentionally left blank. This page is intentionally left blank. Preface This ETERNUS Multipath Driver User's Guide describes the features, functions, and operation of the "ETERNUS Multipath Driver" (hereafter referred to as "Multipath

More information

VMware vsphere with ESX 4 and vcenter

VMware vsphere with ESX 4 and vcenter VMware vsphere with ESX 4 and vcenter This class is a 5-day intense introduction to virtualization using VMware s immensely popular vsphere suite including VMware ESX 4 and vcenter. Assuming no prior virtualization

More information

Configuration Cheat Sheet for the New vsphere Web Client

Configuration Cheat Sheet for the New vsphere Web Client Configuration Cheat Sheet for the New vsphere Web Client 1-800-COURSES www.globalknowledge.com Configuration Cheat Sheet for the New vsphere Web Client Bill Ferguson, VCI3, 4, 5, MCT, MCSE, MCP+I, CCSI,

More information

VMware ESX Server Software for Dell PowerEdge Servers. Deployment Guide. support.dell.com

VMware ESX Server Software for Dell PowerEdge Servers. Deployment Guide.   support.dell.com VMware ESX Server 2.5.1 Software for Dell PowerEdge Servers Deployment Guide www.dell.com support.dell.com VMware ESX Server 2.5.1 Software for Dell PowerEdge Servers Deployment Guide www.dell.com support.dell.com

More information

HUAWEI SAN Storage Host Connectivity Guide for VMware ESXi Servers

HUAWEI SAN Storage Host Connectivity Guide for VMware ESXi Servers Technical White Paper HUAWEI SAN Storage Host Connectivity Guide for VMware ESXi Servers OceanStor Storage VMware Huawei Technologies Co., Ltd. 2017-09-28 Copyright Huawei Technologies Co., Ltd. 2017.

More information

ETERNUS SF AdvancedCopy Manager SRA Version 2.4. User's Guide. Windows(64)

ETERNUS SF AdvancedCopy Manager SRA Version 2.4. User's Guide. Windows(64) ETERNUS SF AdvancedCopy Manager SRA Version 2.4 User's Guide Windows(64) B1WS-0994-04ENZ0(03) June 2017 Preface Purpose This manual explains how to install and customize ETERNUS SF AdvancedCopy Manager

More information

Install ISE on a VMware Virtual Machine

Install ISE on a VMware Virtual Machine ISE Features Not Supported in a Virtual Machine, page 1 Supported VMware Versions, page 1 Support for VMware vmotion, page 2 Support for Open Virtualization Format, page 2 Virtual Machine Requirements,

More information

Setting Up Cisco Prime LMS for High Availability, Live Migration, and Storage VMotion Using VMware

Setting Up Cisco Prime LMS for High Availability, Live Migration, and Storage VMotion Using VMware CHAPTER 5 Setting Up Cisco Prime LMS for High Availability, Live Migration, and Storage VMotion Using VMware This chapter explains setting up LMS for High Availability (HA), Live migration, and, Storage

More information

Veritas Access. Installing Veritas Access in VMWare ESx environment. Who should read this paper? Veritas Pre-Sales, Partner Pre-Sales

Veritas Access. Installing Veritas Access in VMWare ESx environment. Who should read this paper? Veritas Pre-Sales, Partner Pre-Sales Installing Veritas Access in VMWare ESx environment Who should read this paper? Veritas Pre-Sales, Partner Pre-Sales Veritas Access Technical Brief Contents OVERVIEW... 3 REQUIREMENTS FOR INSTALLING VERITAS

More information

ETERNUS Veritas Operations Manager Storage Insight Plug-in 1.0 User s Guide P2X ENZ0

ETERNUS Veritas Operations Manager Storage Insight Plug-in 1.0 User s Guide P2X ENZ0 ETERNUS Veritas Operations Manager Storage Insight Plug-in 1.0 User s Guide This page is intentionally left blank. Preface This manual explains how to use and operate the ETERNUS Veritas Operations Manager

More information

Design Guide (Basic) FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems. System configuration design

Design Guide (Basic) FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems. System configuration design FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Design Guide (Basic) System configuration design Table of Contents 1. Function Overview 14 2. Basic Functions

More information

FUJITSU Storage ETERNUS AF series and ETERNUS DX S4/S3 series Non-Stop Storage Reference Architecture Configuration Guide

FUJITSU Storage ETERNUS AF series and ETERNUS DX S4/S3 series Non-Stop Storage Reference Architecture Configuration Guide FUJITSU Storage ETERNUS AF series and ETERNUS DX S4/S3 series Non-Stop Storage Reference Architecture Configuration Guide Non-stop storage is a high-availability solution that combines ETERNUS SF products

More information

Setup for Failover Clustering and Microsoft Cluster Service. 17 APR 2018 VMware vsphere 6.7 VMware ESXi 6.7 vcenter Server 6.7

Setup for Failover Clustering and Microsoft Cluster Service. 17 APR 2018 VMware vsphere 6.7 VMware ESXi 6.7 vcenter Server 6.7 Setup for Failover Clustering and Microsoft Cluster Service 17 APR 2018 VMware vsphere 6.7 VMware ESXi 6.7 vcenter Server 6.7 You can find the most up-to-date technical documentation on the VMware website

More information

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Deployment and Setup Guide for 7.2.1 release January 2019 215-13884_A0 doccomments@netapp.com Table of Contents

More information

Install ISE on a VMware Virtual Machine

Install ISE on a VMware Virtual Machine ISE Features Not Supported in a Virtual Machine, page 1 Supported VMware Versions, page 1 Support for VMware vmotion, page 2 Support for Open Virtualization Format, page 2 Virtual Machine Requirements,

More information

VMware vsphere with ESX 4.1 and vcenter 4.1

VMware vsphere with ESX 4.1 and vcenter 4.1 QWERTYUIOP{ Overview VMware vsphere with ESX 4.1 and vcenter 4.1 This powerful 5-day class is an intense introduction to virtualization using VMware s vsphere 4.1 including VMware ESX 4.1 and vcenter.

More information

VDCA550 Study Guide. VDCA550 Study Guide - Section 1 Page 1

VDCA550 Study Guide. VDCA550 Study Guide - Section 1 Page 1 VDCA550 Study Guide Written by: Paul E. Grevink Adventures in a Virtual World: http://paulgrevink.wordpress.com/ e: paul.grevink@gmail.com t: @paulgrevink VDCA550 Study Guide - Section 1 Page 1 Contents

More information

Testpassport http://www.testpassport.net Exam : VCP-410 Title : VMware Certified Professional on VI4 Version : Demo 1 / 5 1.Which of the following are valid sub-profile configurations that may be edited

More information

Setup for Failover Clustering and Microsoft Cluster Service

Setup for Failover Clustering and Microsoft Cluster Service Setup for Failover Clustering and Microsoft Cluster Service Update 1 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 This document supports the version of each product listed and supports all subsequent

More information

VMware vsphere 6.0 / 6.5 Infrastructure Deployment Boot Camp

VMware vsphere 6.0 / 6.5 Infrastructure Deployment Boot Camp Title: Summary: Length: Overview: VMware vsphere 6.0 / 6.5 Infrastructure Deployment Boot Camp Class formats available: Live In-Classroom Training (LICT) Mixed class with Classroom and Online Instruction

More information

FUJITSU Storage ETERNUS Multipath Driver 2 (for AIX) Installation Information

FUJITSU Storage ETERNUS Multipath Driver 2 (for AIX) Installation Information FUJITSU Storage ETERNUS Multipath Driver 2 (for AIX) Installation Information Oct 2016 Contents Contents... 1 Supported Operating System (OS) Versions... 1 Supported Disk Storage Systems... 1 Connection

More information

vsphere Installation and Setup Update 2 Modified on 10 JULY 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5

vsphere Installation and Setup Update 2 Modified on 10 JULY 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 vsphere Installation and Setup Update 2 Modified on 10 JULY 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 You can find the most up-to-date technical documentation on the VMware website at:

More information

NexentaStor VVOL

NexentaStor VVOL NexentaStor 5.1.1 VVOL Admin Guide Date: January, 2018 Software Version: NexentaStor 5.1.1 VVOL Part Number: 3000-VVOL-5.1.1-000065-A Table of Contents Preface... 3 Intended Audience 3 References 3 Document

More information

Install ISE on a VMware Virtual Machine

Install ISE on a VMware Virtual Machine Supported VMware Versions, page 1 Support for VMware vmotion, page 1 Support for Open Virtualization Format, page 2 Virtual Machine Requirements, page 3 Virtual Machine Resource and Performance Checks,

More information

Vmware VCP410. VMware Certified Professional on vsphere 4. Download Full Version :

Vmware VCP410. VMware Certified Professional on vsphere 4. Download Full Version : Vmware VCP410 VMware Certified Professional on vsphere 4 Download Full Version : http://killexams.com/pass4sure/exam-detail/vcp410 A. The ESX Host has 2 AMD dual-core CPUs B. 8 vcpu support is only available

More information

HP StoreVirtual Storage Multipathing Deployment Guide

HP StoreVirtual Storage Multipathing Deployment Guide HP StoreVirtual Storage Multipathing Deployment Guide HP Part Number: AX696-96377 Published: January 2015 Edition: 6 Copyright 2011, 2015 Hewlett-Packard Development Company, L.P. Revision History Revision

More information

VI3 to vsphere 4.0 Upgrade and New Technology Ultimate Bootcamp

VI3 to vsphere 4.0 Upgrade and New Technology Ultimate Bootcamp VI3 to vsphere 4.0 Upgrade and New Technology Ultimate Bootcamp Course Length: 2 Days Course Overview This instructor-led course covers everything the student needs to know to upgrade from VMware 3.x to

More information

COPYRIGHTED MATERIAL. Windows Server 2008 Storage Services. Chapter. in this chapter:

COPYRIGHTED MATERIAL. Windows Server 2008 Storage Services. Chapter. in this chapter: Chapter 1 Windows Server 2008 Storage Services Microsoft Exam Objectives covered in this chapter: ÛÛConfigure storage. May include but is not limited to: RAID types, Virtual Disk Specification (VDS) API,

More information

Dell EMC SC Series Storage with SAS Front-end Support for VMware vsphere

Dell EMC SC Series Storage with SAS Front-end Support for VMware vsphere Dell EMC SC Series Storage with SAS Front-end Support for VMware vsphere Abstract This document describes how to configure VMware vsphere hosts equipped with supported SAS HBAs to access SAN storage on

More information

Dell EMC SC Series Storage: Microsoft Multipath I/O

Dell EMC SC Series Storage: Microsoft Multipath I/O Dell EMC SC Series Storage: Microsoft Multipath I/O Dell EMC Engineering June 2017 A Dell EMC Best Practices Guide Revisions Date Description 10/11/2010 Initial release 10/21/2011 Corrected errors 11/29/2011

More information

Install ISE on a VMware Virtual Machine

Install ISE on a VMware Virtual Machine Supported VMware Versions, page 1 Support for VMware vmotion, page 1 Support for Open Virtualization Format, page 2 Virtual Machine Requirements, page 3 Virtual Machine Resource and Performance Checks,

More information

Preparing Virtual Machines for Cisco APIC-EM

Preparing Virtual Machines for Cisco APIC-EM Preparing a VMware System for Cisco APIC-EM Deployment, page 1 Virtual Machine Configuration Recommendations, page 1 Configuring Resource Pools Using vsphere Web Client, page 4 Configuring a Virtual Machine

More information

Infortrend VMware Solutions

Infortrend VMware Solutions Infortrend VMware Solutions Best Practice Version: 1.2 Updated: Nov., 2017 Abstract: This document describes the best practices for using Infortrend storage in VMware environment. Infortrend storage provides

More information

Preparing Virtual Machines for Cisco APIC-EM

Preparing Virtual Machines for Cisco APIC-EM Preparing a VMware System for Cisco APIC-EM Deployment, on page 1 Virtual Machine Configuration Recommendations, on page 1 Configuring Resource Pools Using vsphere Web Client, on page 4 Configuring a Virtual

More information

VMware vcenter Site Recovery Manager 4.1 Evaluator s Guide EVALUATOR'S GUIDE

VMware vcenter Site Recovery Manager 4.1 Evaluator s Guide EVALUATOR'S GUIDE VMware vcenter Site Recovery Manager 4.1 EVALUATOR'S GUIDE Table of Contents. Getting Started.... 3 About VMware vcenter Site Recovery Manager.... 3 About This Guide.... 3 Intended Audience.... 3 Assumptions....

More information

Data Protection Guide

Data Protection Guide SnapCenter Software 4.0 Data Protection Guide For VMs and Datastores using the SnapCenter Plug-in for VMware vsphere March 2018 215-12931_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding

More information

A. Both Node A and Node B will remain on line and all disk shelves will remain online.

A. Both Node A and Node B will remain on line and all disk shelves will remain online. Volume: 75 Questions Question No: 1 On a FAS8040, which port is used for FCoE connections? A. e0m B. e0p C. 0a D. e0h Answer: D Question No: 2 Click the Exhibit button. Referring to the diagram shown in