F. RELEASE NOTES for AP88xx Metered Rack PDU AP89xx Switched Rack PDU AP86xx Metered-by-Outlet with Switching Rack PDU
|
|
- Annabella Kelley
- 5 years ago
- Views:
Transcription
1 RELEASE NOTES for AP88xx Metered Rack PDU AP89xx Switched Rack PDU AP86xx Metered-by-Outlet with Switching Rack PDU Released: November 21, 2013 Affected Revision Levels: apc_hw05_aos_613.bin Network Management Card Operating System & TCP/IP Stack for Hardware Platform v05 apc_hw05_rpdu2g_609.bin Switched/Metered Rack PDU2 Application powernet410.mib PowerNet(R) SNMP Management Information Base (MIB) For details on upgrading the firmware for your Rack PDU, see the User's Guide on the APC Web site ( Schneider Electric Device IP Configuration Wizard v5.0.2 The Wizard is a Windows application designed specifically to remotely configure the basic TCP/IP settings of Network Management Cards. The Wizard runs on Windows(R) 2000, Windows 2003, Windows Vista, Windows XP, Windows 7, Windows Server 2008, Windows 8, and Windows The Wizard is available as a free download from the APC Web site. On the Web site, search by part number SFDIPW502 to find the downloadable file. Table of Contents: 1.0 OS & TCP/IP Stack Modifications (apc_hw05_aos_613.bin) 1.1 COMPATIBILITY 1.2 KNOWN ISSUES IN THIS VERSION 1.3 NEW FEATURES & ENHANCEMENTS SINCE AOS v BUGS FIXED IN THIS VERSION SINCE AOS v Switched/Metered Rack PDU2 Application (apc_hw05_rpdu2g_609.bin) 2.1 COMPATIBILITY 2.2 KNOWN ISSUES IN THIS VERSION 2.3 NEW FEATURES & ENHANCEMENTS SINCE RPDU2 v BUGS FIXED IN THIS VERSION SINCE RPDU2 v Schneider Electric Device IP Configuration Wizard v COMPATIBILITY 4.0 Miscellaneous 4.1 RECOVERING FROM A LOST PASSWORD 4.2 EVENT SUPPORT LIST 4.3 POWERNET MIB REFERENCE GUIDE Page 1
2 1.0 OS & TCP/IP Stack Modifications (apc_hw05_aos_613.bin) 1.1 COMPATIBILITY apc_hw05_rpdu2g_609.bin Rack Mount Power Distribution Unit KNOWN ISSUES IN THIS VERSION 1. The SNMPv1 "communitystring" OID allows 15 characters but should allow The NMC Upgrade utility supports ASCII characters only for username and password. 3. When upgrading from 5.0x systems, if NTP (network time protocol) is not enabled, the NMC clock will need to be set manually. 4. Non-ASCII characters conveyed to an ISX Manager will not display properly in ISXM. 5. The following fields do not accept UTF-8 characters (they accept ASCII only): - any numeric field (only Arabic numbers are accepted) - the Datalog FTP Server name. 6. The following warning events do NOT cause the Network Management Card to send an SNMP trap: - System: Detected an unauthorized user attempting to access the FTP interface. - System: Password Changed 7. In the Config.ini file, the [EventActionConfig] keys may report incorrect data when performing a mass configuration. 8. The device and outlet user privileges in the CLI are not consistent with the device and outlet user privileges in the Web interface. 9. Using the Config.ini file to configure the following keys in the [SystemUserManager] and [SystemDateTime] sections may cause the Web interface to display the following values incorrectly: - ReadOnlyUserName - DeviceUserName - AdminUserName - NTPPrimaryServer - NTPSecondaryServer 10. In the Web interface, the Primary and Secondary RADIUS servers accept invalid IP address values. 11. In the Config.ini: the SystemDateTime Server keys return strange values when long strings are applied. 12. There are different Date Formats on the NMC General/About page. 13. The DNS Domain Name validation doesn't conform to RFC 1035 standards for formatting. Page 2
3 14. The Config.ini keywords "LinkDisplay" and "LinkName" in the [SystemLinks] section accept a NULL value. 15. The Trap receiver NMS settings incorrectly allow for a NULL entry. 16. The SNMP v1 and v3 Community Access Addresses incorrectly allow for a NULL entry. 17. The SNMP v1 Trap Community Name incorrectly accepts values greater than the max of 15 and NULL. 18. The Syslog Server address incorrectly accepts a NULL entry. 19. When data log rotation is enabled or disabled, the event log will log the same event "System: Configuration change. Data log rotation enable". This is misleading if the rotation was disabled. 20. RPDU may warmstart during periods of large network activity. 21. Configuring a fourth recipient may cause the following event, "System: Could not mail, queue full." 22. Several issues have been identified when upgrading the AOS from v5.xx to v6.xx. It is important to review Knowledge Base (KBase) prior to upgrading Rack PDUs. 1.3 NEW FEATURES & ENHANCEMENTS SINCE AOS v Incorporates the new Schneider Electric color scheme and web navigation. 2. SSL/TLS SMTP authentication support. 3. Built-in network firewall. 4. Single Debug File download for technical support use. 5. Simultaneous web browser and CLI sessions for up to 4 users. 6. Two new levels of access available, Super User and Network-only User. 7. Multiple users of the same type (with the exception of Super User) can now be created. 8. Support for strong passwords and password policies. 9. Ability to add a message to the log in screen. 10. Additional CLI commands available for new functionality. 1.4 BUGS FIXED IN THIS VERSION SINCE AOS v Config INI keyword "Protocol" in the [NetworkSYSLOG] section is not indexed. 2. Setting data log interval to 0 seconds it does not give error message. 3. Range for FTP port given in CLI is wrong. Page 3
4 4. Only four trap receivers show up on Group Event Actions list. 5. User Link Display name configuration exceeds 20-characters when configuring via config.ini file. 6. The Quick Links Display name configuration only allows 6 characters in the web text box. 7. The Config.ini keywords "LinkDisplay" and "LinkName" in the [SystemLinks] section accepts a NULL value. 8. In SNMP: sysuptime OID is continuously lagging from actual NMC UP time value. 9. NMC does not respond to ipadentnetmask OID via SNMP. 10. The ethernet port speed is being reported improperly via SNMP OID Receiver#Port Keyword does not work or show up in config.ini for recipient's port number option. 12. NMC does not handle HELO SMTP command properly when SMTP server rejects EHLO initially. 13. Unable to log into the Web Application following an SCP transfer when using RADIUS authentication. 14. Some features of the management card application do not work correctly in the web UI when using Google Chrome browser. 15. In the CLI, the "system" command accepts Name, Contact, and Location values that exceed the character limit, but the UI truncates those values in the logon banner. 16. User names can be defined using the Config.ini file, but by default password keys are no longer included. Transferring an unedited Config.ini file in the old format (with password keys) can cause unintended user name/ password pairs unless the user name field is removed from the file. 17. When SNMPv3 access is enabled, disabling SNMPv1 access by clearing the "Enable SNMPv1 access" check box has no effect. 18. In the Config.ini file, the [SystemPreference] key EventLogDisplay shows: - 0 instead of Disabled and - 1 instead of Enabled. 19. In SNMP browsers, UDP ports are not reported correctly and all TCP ports except the Web port are not shown. 20. The NMC supports six SNMP trap receivers, but only four can be configured to receive event notifications. 21. In the CLI, the Primary and Secondary RADIUS server commands append the previous server secret to the end of the new server secret. 22. Domain Name parameter displays result as "Success" for Invalid value in the CLI. 23. The User Link Display name configuration exceeds 20 characters when using a Config.ini file. 24. The Quick Links Display name configuration only allows 6 characters in the web text box. 25. In the Config.ini: SystemLinks, LinkName and LinkDisplay fields truncate values which are too long. Page 4
5 26. The Config.ini for RMS Configuration incorrectly accepts values greater than allowed. 27. RPDU does not respond to ipadentnetmask OID via SNMP. 28. Some event logs may not be displayed when the event log filter is set to an option other than "All Logs". 29. In SNMP: sysuptime OID is continuously lagging from actual NMC UP time value. 30. May not be able to upload a config.ini file via the web interface when HTTPS is enabled. Workaround is to use FTP method. 2.0 Switched/Metered Rack PDU2 Application (apc_hw05_rpdu2g_609.bin) 2.1 COMPATIBILITY apc_hw05_aos_613.bin Network Management Card OS & TCP/IP Stack See 1.0 OS & TCP/IP Stack Modifications (apc_hw05_aos_613.bin) for a list of modifications and enhancements that affect this application version. 2.2 KNOWN ISSUES IN THIS VERSION 1. ISX Manager's Building Management System does not recognize AP88XX, AP89XX, or AP86XX SKUs in the "Select BMS Slave Devices" screen. 2. Selecting the "Launch Log in New Window" button on the Data Log web page will sometimes launch a new window with no data records, only column headers. 3. The data log will sometimes fill to the maximum allowed number of entries when it has been configured to a value less than the maximum. 4. Should a user attempt to configure a phase's Overload Alarm with a value that is above the maximum load value, configuration errors in Near Overload and Low Load Warning values will not be reported on the screen. These entries will be rejected along with the Overload Alarm entry, but notification will not be put on the screen for those fields. 5. When a large number of outlet groups are controlled simultaneously, some controls may not complete. Additionally, the Rack PDU may reboot. 6. Telnet session may close unexpectedly after performing the CLI command to control many outlets at the same time. The command will complete, but the user may have to log back in to the telnet session. 7. If a "Cancel Pending Commands" is issued when more than 6 outlet group commands are in progress, some of the cancel commands may not get processed. 8. In some situations, such as when a large number of events are generated at the same time, some events may not get logged. This may also cause the active alarm list to not display an active alarm, or to display an alarm that has actually been cleared. 9. If a breaker is tripped on an AP86xx SKU with two outlet banks (AP8641, AP8653), outlets 9 through 16 may report incorrect measurements. Page 5
6 10. A complete config.ini upload to a Rack PDU in a Network Port Sharing group may take a long time. For example, for a Rack PDU in a Network Port Sharing group with three other Rack PDUs, it may take 30 minutes to complete. 11. Rack PDU phase and bank peak current reset SNMP OIDs may not work properly. rpdu2phaseconfigphasepeakcurrentreset ( ) and rpdu2bankconfigbankpeakcurrentreset ( ) 12. CLI outlet commands are not properly handling outlet names as parameters. For Rack PDUs in a Network Port Sharing group, or for AP84xx SKUs, please use the outlet number instead as a parameter. 2.3 NEW FEATURES & ENHANCEMENTS SINCE RPDU2 v Incorporates the new Schneider Electric color scheme and web navigation. 2. Cisco EnergyWise is supported in this firmware release. 3. Wireless RF Code is supported in this firmware release. 4. Network Port Sharing (NPS) automatic firmware upgrade is supported in this release. This allows the Host RPDU to pass future firmware upgrades to the Guest RPDUs. 5. For multiple RPDUs in a Network Port Sharing (NPS) group, the LCD will now always show the display ID in the upper left corner of the LCD. 6. For AP86xx SKUs with Metering-by-Outlet, the low current squelch for outlets has been reduced from 0.5 amps to 0.3 amps. Additional detailed information on squelching and accuracy is available in knowledge base FA at 7. Capability to remotely enable or disable the LCD added. 8. Peak value indicators added for phase and bank loads. 9. LCD blink function added to web page for help in locating RPDU. 10. For 3-phase SKUs, added display of phase to phase input voltages to the CLI, LCD, and SNMP interfaces. It was previously only available on the web interface. 11. For informational purposes, apparent power and power factor added for phases and device. 2.4 BUGS FIXED IN THIS VERSION SINCE RPDU2 v CLI interface does not have a command that allows the user to know that an outlet user is disabled. Therefore, if a CLI user attempts to assign outlets to this disabled user, the command will fail with a "parameter error", but the user will not know the actual reason. 2. After a "CAN bus off" alarm has been resolved, the clearing event is not generated and the alarm remains in the active list. 3. Outlet controls issued to outlets that are already in the desired state are logged in the event log. This is different than previous behavior. Page 6
7 4. All IPv6 addresses are now shown on the LCD. 5. Added capability to set temperature and humidity hysteresis from CLI interface. 6. Outlet scheduling web page should default schedule name to the next available number instead of always "1" which causes a failure if not changed. 7. Humidity thresholds are now restricted to actual sensor limits. 3.0 Schneider Electric Device IP Configuration Wizard v COMPATIBILITY apc_hw05_aos_613.bin and prior Network Management Card OS & TCP/IP Stack 4.0 Miscellaneous 4.1 RECOVERING FROM A LOST PASSWORD See the User's Guide on the APC Web site ( for instructions on how to recover from a lost password. 4.2 EVENT SUPPORT LIST For the event names and event codes for all events supported for a currently connected APC device, first retrieve the config.ini file from the RPDU. To use FTP to retrieve the config.ini file from a configured RPDU: 1. Open a connection to the RPDU, using its IP Address: ftp> open <ip_address> 2. Log on using the Administrator user name and password. 3. Retrieve the config.ini file containing the settings of the RPDU. ftp> get config.ini The file is written to the folder from which you launched FTP. In the config.ini file, find the section heading [EventActionConfig]. In the list of events under that section heading, substitute "0x" for the initial "E" in the code for any event to obtain the hexadecimal event code shown in the user interface and in the documentation. For example, the hexadecimal code for the code "E0033" in the config.ini file (for the event "System: Configuration change") is "0x0033". Page 7
8 4.3 POWERNET MIB REFERENCE GUIDE NOTE: The MIB Reference Guide, available on the APC Web site ( explains the structure of the MIB, types of OIDs, and the procedure for defining trap receivers. For information on specific OIDs, use a MIB browser to view their definitions and available values directly from the MIB itself. You can view the definitions of traps at the end of the MIB itself (powernet410.mib, downloadable from the APC Web site, by Schneider Electric. All rights reserved. InfraStruxure, Symmetra, MGE, Galaxy, and Smart-UPS are owned by Schneider Electric Industries S.A.S., American Power Conversion Corporation, or their affiliated companies. All other trademarks are property of their respective owners. Schneider Electric Documentation Part Number: F Page 8
RelNotes x-EN 20 NOV APC by Schneider Electric (www.apc.com) APC part number: D
APC by Schneider Electric (www.apc.com) APC part number: 990-3864D RELEASE NOTES for AP88xx Metered Rack PDU AP89xx, AP86xx Switched Rack PDU Released: 16 August 2012 IMMEDIATELY UPGRADE ALL rpdu DEVICES
More informationA. APC by Schneider Electric ( APC part number: A. RELEASE NOTES for PDPM150G6F, PDPM150L6F, PDPM175G6H
APC by Schneider Electric (www.apc.com) APC part number: 990-4633A 990-4633A RELEASE NOTES for PDPM150G6F, PDPM150L6F, PDPM175G6H Released: 31 January 2013 Affected Revision Levels: apc_hw05_aos_519.bin
More informationA. APC by Schneider Electric ( APC part number: A. RELEASE NOTES for AP8958, AP8958EU3, AP8958NA3 Switched Rack PDU
APC by Schneider Electric (www.apc.com) APC part number: 990-4766A 990-4766A RELEASE NOTES for AP8958, AP8958EU3, AP8958NA3 Switched Rack PDU Revised: June 27, 2012 Affected Revision Levels: apc_hw05_aos_605.bin
More informationC. PowerNet(R) SNMP Management Information Base (MIB)
RELEASE NOTES for: ACDA901 Refrigerant Distribution Unit ACOA50x Cooling Modules ACRA10x Cooling Modules Schneider Electric documentation part number: 990-3690C Revised: January 2015 Affected Revision
More informationNetwork Management Card for Galaxy 300. Schneider Electric Device IP Configuration Wizard
Release Notes 990 9953A 08/2017 Network Management Card for Galaxy 300 AP9630/31 and AP9635CH What s in This Document Schneider Electric Device IP Configuration Wizard...1 Affected Revision Levels...1
More informationNetwork Management Card 2 (NMC 2) Firmware v6.5.6 for Smart-UPS and Single-Phase Symmetra Release Notes
Network Management Card 2 (NMC 2) Firmware v6.5.6 for and Release Notes Table of Contents Affected Revision Levels... 1 Schneider Electric Device IP Configuration Wizard... 1 New Features... 2 Fixed Issues...
More informationSchneider Electric Device IP Configuration Wizard
Release Notes 990 5784A-001 08/2017 Network Management Card 2 AP9630 (CH) Network Management Card AP9631 (CH) Network Management Card AP9635 (CH) Network Management Card What s in This Document Schneider
More informationNetwork Management Card 2 (NMC 2) Firmware v6.6.4 for Smart-UPS and Single-Phase Symmetra Release Notes
Network Management Card 2 (NMC 2) Firmware v6.6.4 for and Release Notes Table of Contents Affected Revision Levels... 1 Schneider Electric Device IP Configuration Wizard... 1 New Features... 2 Fixed Issues...
More informationWhat s in This Document. 4.0 Device IP Configuration Wizard...5
Release Notes 990 3910F Release date: 08/2018 For details on upgrading the InRow SC air conditioner firmware, see the InRow RD Online Guide, available from the InRow RD product page of the Schneider Electric
More informationSmartZone G5 Firmware Release Notes 2.2.2
SmartZone G5 Firmware Release Notes 2.2.2 1 Contents General... 2 Supported Hardware... 2 Tested Application Compatibility... 2 Released Production Files... 2 Product Upgrade... 2 New Features... 3 New
More informationTable Of Contents. 1. Introduction... 1
User Manual Table of Content Table Of Contents 1. Introduction... 1 1.1 Brief Introduction to Web Interfaces... 1 1.2 How to Log In... 1 1.3 General Setting... 2 1.3.1 Date and Time Setting... 2 1.3.2
More informationRelease Note of RMCARD 202/203 Ver (Release Date: 06/09/2017):
Release Note of RMCARD 202/203 Ver. 2.29 (Release Date: 06/09/2017): Unexpected reboot when E-mail notification was executed via Office365 SMTP Server. Fixed the system not sending the login fail event
More informationIntegrate APC Smart UPS
Publication Date: November 18, 2016 Abstract This guide provides instructions to configure APC Smart-UPS to send the syslog events to EventTracker. Scope The configurations detailed in this guide are consistent
More informationInitial configuration requirements 7. Overview 7 InfraStruXure Manager Setup Wizard 8
Contents Introduction 1 Before You Start 1 Overview 2 Supported devices 4 APC and User Local Area Networks (LANs) 5 Network Time Protocol (NTP) server feature 5 How to restore access to the server 6 Initial
More information- 1 - Dominion PX Overview: Dominion PX refers to Raritan s family of intelligent power distribution units.
- 1 - Release Notes for Dominion PX Software Version 1.3.0 (firmware version will be displayed as 01.03.00 in the GUI after an upgrade) Version: DPX 1.3 Release Notes, Revision 1.3 Date: February 20, 2009
More informationEnvironmental Manager: Main Module
Contents Introduction--1 Product Description....................................... 1 Features of the 1 Initial setup 2 Access Procedures....................................... 3 Overview 3 Access priority
More informationVERTIV. RPC2 Communications Module Release Notes FIRMWARE VERSION _00290, AUGUST 3, Release Notes Section Outline
VERTIV RPC2 Communications Module Release Notes FIRMWARE VERSION 14.0.0.3_00290, AUGUST 3, 2018 Release Notes Section Outline 1 Version and Compatibility Information 2 Features and Enhancements 3 Upgrade
More informationTable of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4
User Manual Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 2 5. Web Interface... 4 1. Introduction The ServerLink PDU is a network ready device designed
More informationOperation. Symmetra MW II. Parallel System with Internal Bypass Static Switch. Normal Normal. UPS Summary. X405 UPS Summary.
X008B X010 X007 X021 X022 X012 X008A X014A X011 X405 X013 X017 X014B UPS Summary UPS Summary ~ ~ ~ ~ Normal Normal Normal Normal Operation Symmetra MW II Parallel System with Internal Bypass Static Switch
More informationVERTIV. RPC2 Communications Module Release Notes FIRMWARE VERSION _00109, SEPTEMBER 8, Release Notes Section Outline
VERTIV RPC2 Communications Module Release Notes FIRMWARE VERSION 12.0.0.5_00109, SEPTEMBER 8, 2017 Release Notes Section Outline 1 Version and Compatibility Information 2 Features and Enhancements 3 Upgrade
More informationOperation. Network Management Card for G-Type Rack Power Filter. 120 Vac 15 A 20 A
Operation Network Management Card for G-Type Rack Power Filter 120 Vac 15 A 20 A Contents Using the Network Management Card... 1 Product Features.......................................... 1 Access Priorities
More informationImportant! Read this Information Bulletin before Upgrading Switched Rack PDU products to rpdu Firmware Version or 3.5.8
Important! Read this Information Bulletin before Upgrading Switched Rack PDU products to rpdu Firmware Version 3.5.7 or 3.5.8 This Information Bulletin is relevant for you if 1. The part number of your
More informationUser Manual. Per Port Monitoring Models
User Manual Per Port Monitoring Models Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 5 5. Web Interface... 6 1. Introduction The ServerLink Per Port
More information5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA
Management Interface The management interface for this PDU model is transitioning to a new technology platform. The new interface can be distinguished by a USB-A port (for EnviroSense2 modules) in place
More informationECO PDU Power Distribution Unit
ECO PDU Distribution Unit PE6108/PE6208/PE8108/PE8208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage.
More informationPN5212/PN5320/PN7212/PN7320
PN522/PN520/PN722/PN720 Power Over the NET Power Distribution Units ALTUSEN Power Over the NET products are Power Distribution Units that offer outlet level control combined with remote access to give
More informationSwitched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.
Switched XPDU 15A Model User & Installation Manual www.xpcc.com 2014. All rights reserved. (Rev 10/02/14) Table of Contents Introduction...4 PDU Package...4 Function...4 Interface...4 Installation...5
More informationDominion PX Overview: Dominion PX refers to Raritan s family of intelligent power distribution units.
- 1 - elease Notes for Dominion PX Software Version 1.1 Version: DPX 1.1 Release Notes, Revision 1.0 Date: March 17, 2008 Effective: Immediately. Applicability: Dominion PX models: All models. Release
More information25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA
25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC 309 60A Red 415V, 0U, TAA MODEL NUMBER: PDU3XEVSR6G60B Highlights 25.2kW 240V 3-phase switched 1.8m
More informationADDENDUM. NetworkAIR FM. Contents. Management Card Wizard--1. File Transfers--10
Contents Management Card Wizard--1 Introduction....................................... 1 Overview 1 System requirements 2 Configuring Air Conditioner settings 2 Installing the Wizard 2 Online Help 2 Quick
More informationModel# ANI SWH. Ver. 1.1
PDU Per Outlet Control and Total Current Monitoring User Manual Model# ANI-15115-08SWH Ver. 1.1 Table of Contents 1. Introduction... 1 2. PDU Package... 2 3. Function... 3 4. Installation... 5 5. Web Interface...
More informationTable of Contents. 1. Introduction Package Contents Function Installation Web Interface... 5
User Manual Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 4 5. Web Interface... 5 6. Specifications... 8 1. Introduction The ServerLink PDU is a network
More information- 1 - Dominion PX Overview: Dominion PX refers to Raritan s family of intelligent power distribution units.
- 1 - Release Notes for Dominion PX Software Version 1.2.7 (firmware version will be displayed as 01.02.07 in the GUI after an upgrade) Version: DPX 1.2.7 Release Notes, Revision 1.3 Date: January 7, 2009
More informationRelease Note of RMCARD 302/303 Ver. 2.19(Release Date: 06/09/2017): Ver. 2.18(Release Date: 08/03/2016):
Release Note of RMCARD 302/303 Ver. 2.19(Release Date: 06/09/2017): Unexpected reboot when E-mail notification was executed via Office365 SMTP Server. "Turn Off capacity threshold" could not be displayed
More informationCYBER POWER SYSTEMS, INC. INTELLIGENT PDU FIRMWARE RELEASE NOTES V1.1.4 Page 1/7
CYBER POWER SYSTEMS, INC. REMOTE MANAGEMENT CARD FIRMWARE RELEASE NOTES Applicable Products: RMCARD205, RMCARD305 Version 1.1.4 (Release Date: Aug. 6, 2018) - Add the Battery Status page to the Web Interface
More informationNetwork Management Card. User Manual
User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1
More informationVERTIV. RPC2 Communications Module Release Notes FIRMWARE VERSION _00245, FEBRUARY 19, Release Notes Section Outline
VERTIV RPC2 Communications Module Release Notes FIRMWARE VERSION 13.0.0.3_00245, FEBRUARY 19, 2018 Release Notes Section Outline 1 Version and Compatibility Information 2 Features and Enhancements 3 Upgrade
More informationPE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU
PE8208 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU 8 outlets 20A (UL derated 16A) / 16A Outlet Power Measurement The PE8208 eco PDU is intelligent PDUs that contains 8 AC outlets and is available
More informationPE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU. 8 outlets. 20A (UL derated 16A) / 16A. Outlet Power Measurement
PE8208 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU 8 outlets 20A (UL derated 16A) / 16A Outlet Power Measurement The PE8208 eco PDU is intelligent PDUs that contains 8 AC outlets and is available
More informationREMOTE MANAGEMENT CARD FIRMWARE RELEASE NOTES. Ver (Release Date: Apr. 03, 2018)
REMOTE MANAGEMENT CARD FIRMWARE RELEASE NOTES Applicable Product(s): RMCARD205, RMCARD305, RMCARD205TAA, RMCARD305TAA Ver. 1.12 (Release Date: Apr. 03, 2018) Support Firmware Update function via Secure
More informationNetwork Management Card. User Manual
User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1
More informationProduct Description... 1 Internal Management Features... 5 Front Panel... 7 Watchdog Features... 12
Contents Introduction--1 Product Description.................................. 1 Internal Management Features........................... 5 Front Panel........................................ 7 Watchdog
More informationSwitched Rack Power Distribution Unit
Switched Rack Power Distribution Unit AS-216-520-30A-L530 Installation and Quick Start Contents Product Description and Inventory...................... 1 AS-216-520-30A-L530....................... 1 Additional
More informationPower IQ DCIM Monitoring Version 6.2.1
Power IQ DCIM Monitoring Version 6.2.1 These Release Notes contain important information regarding the release of this product, so please read them carefully. We strongly recommend that you read the entire
More informationRelease Note of EPDU-B Ver (Release Date: 03/01/2016):
Release Note of EPDU-B Ver. 2.17 (Release Date: 03/01/2016): Upload configuration by ftp. Support DST (Daylight Saving Time). Add automatic login. Automatic login without enter username/password, the most
More informationUser Manual. InfraStruxure 150 kva Power Distribution Unit PDPB150G6F A Publication Date: 11/2018
User Manual InfraStruxure 150 kva Power Distribution Unit PDPB150G6F 990-4414A Publication Date: 11/2018 Schneider Electric Legal Disclaimer The information presented in this manual is not warranted by
More informationUSER S GUIDE. Contents. InfraStruXure InRow RP. Introduction--1. Control Console--8
Contents Introduction--1 Product Description....................................... 1 Features of the 1 Initial setup 2 Internal Management Features............................... 2 Overview 2 Log on control
More informationRelease Notes for Cisco Video Surveillance High Definition IP Cameras, Release 1.4.1
Release tes for Cisco Video Surveillance High Definition IP Cameras, Release 1.4.1 September 2013 These release notes provide important information for the Cisco Video Surveillance High Definition IP camera,
More informationContent and Purpose of This Guide... 1 User Management... 2
Contents Introduction--1 Content and Purpose of This Guide........................... 1 User Management........................................ 2 Security--3 Security Features.........................................
More informationPDU Utility User Manual Version 3.1
PDU Utility User Manual Version 3.1 Table of Contents 1. Introduction... 1 2. Installation... 2 3. PDU Utility Interface... 7 1. Introduction General PDU (Power Distribution Unit) Utility is a PDU monitoring,
More informationPDU Utility. User Manual
PDU Utility User Manual Table of Contents 1. Introduction... 1 2. Installation... 2 3. PDU Utility Interface... 4 1. Introduction General PDU Utility is PDU monitoring, management software. It has been
More informationRemote Management Card
Remote Management Card RMCARD205 / RMCARD305 User s Manual Rev. 03 The Remote Management Card allows a UPS system and environmental sensor to be managed, monitored, and configured. 2016, CyberPower Systems,
More informationStruxureWare Data Center Expert v7.4.1 Release Notes
StruxureWare Data Center Expert v7.4.1 Release Notes Table of Contents Page # Part Numbers Affected...... 1 Minimum System Requirements... 1 New Features........ 1 Issues Fixed....5 Known Issues...6 Upgrade
More informationRemote Management Card
Remote Management Card RMCARD205 / RMCARD305 User s Manual Rev. 01 The Remote Management Card allows a UPS system and environmental sensor to be managed, monitored, and configured. 2015, CyberPower Systems,
More informationOPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES
OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES www.unipowerco.com Manual No. PDUAC1USM-2 pduac1us-man-rev2-0115.indd 2015 UNIPOWER LLC All Rights Reserved NORTH AMERICA 3900 Coral Ridge Drive,
More informationNMS300 Network Management System Application
NMS300 Network Management System Application Quick Start Guide October 2013 202-11288-02 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product. After installing
More informationMetered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R
Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R APC Metered Rack PDU, Input: 120V, Input Connections: NEMA L5-20P, Cord Length: 10 feet ( 3.05 meters ), Output: 120V, Output Connections:
More informationInfraStruxure Central 6.2 Release Notes
InfraStruxure Central 6.2 Release Notes Table of Contents Page # Part Numbers Affected.......1 Minimum System Requirements...1 New Features........1 Issues Fixed....4 Known Issues......5 Upgrade Procedure...8
More informationRemote Management Card
Remote Management Card RMCARD205 / RMCARD305 User s Manual The Remote Management Card allows a UPS system and environmental sensor to be managed, monitored, and configured. 2017, CyberPower Systems, Inc.
More informationMasterSwitch. User s Guide. Power Distribution Unit AP9211 AP9212 AP9217
MasterSwitch Power Distribution Unit AP9211 AP9212 AP9217 User s Guide Contents MasterSwitch Power Distribution Unit Introduction...1 ProductDescription...1 Front panel 1 LEDs 2 Rear panel 3 InitialSetup...4
More informationVersion /20/2012. User Manual. AP Manager II Lite Business Class Networking
Version 1.0 12/20/2012 User Manual AP Manager II Lite Business Class Networking Table of Contents Table of Contents Product Overview... 1 Minimum System Requirements... 2 Access Point Requirements... 2
More informationUser s Guide. SNMPWEBCARD Firmware Version Revision 3
WARRANTY REGISTRATION: register online today for a chance to win a FREE Tripp Lite product www.tripplite.com/warranty User s Guide SNMPWEBCARD Firmware Version 12.06.0062 Revision 3 Table of Contents 1.
More informationNetBotz BotzWare v4.6.2 Release Notes
NetBotz v4.6.1 Release Notes NetBotz BotzWare v4.6.2 Release Notes Part Numbers Affected NBRK0450 NBRK0550 NBRK0570 NBWL0355 NBWL0355A NBWL0356 NBWL0356A NBWL0455 NBWL0455A NBWL0456 NBWL0456A Affected
More informationCurrent Firmware Release Notes
Current Firmware Release Notes CPI recommends that all econnect PDU customers upgrade to the current firmware version. Release Versions 1.23.126 & 2.23.126: Upgrade Procedure: Download the zip file from
More informationRAMOS PLUS RACK MONITORING SYSTEM INTRODUCTION MANUAL
RAMOS PLUS RACK MONITORING SYSTEM INTRODUCTION MANUAL EN Table of Contents Introduction... 3 What is the RAMOS PLUS and Rack sensor ST3H... 3 RAMOS PLUS Features:... 3 Port assignment information for RAMOS
More informationManagement Settings ORBEM. This chapter provides instructions for configuring Object Request Broker Element Management (ORBEM)
This chapter provides instructions for configuring Object Request Broker Element Management (ORBEM) and Simple Network Management Protocol (SNMP) options. This chapter includes the following sections:
More informationAvocent Corporation ACS 6000 Advanced Console Server Release Notes Version November 10 th, 2010
Avocent Corporation ACS 6000 Advanced Console Server Release Notes Version 2.2.0.19 November 10 th, 2010 This document outlines: 1. Update Instructions 2. Appliance Firmware Version and Language Support
More informationCisco Small Business SF200E Series Advanced Smart Switches
ADMINISTRATION GUIDE Cisco Small Business SF200E Series Advanced Smart Switches Contents Chapter 1: Getting Started 9 Starting the Web-Based Switch Configuration Utility 9 Launching the Utility 10 Logging
More informationTable of Contents SMARTZONE G5 USER MANUAL
G5 PDU User Manual 1 Table of Contents Table of Figures... 5 Section 1 System Overview... 8 Intelligent Network Controller... 8 Connecting the PDU to a LAN Ethernet Port... 8 Connecting the PDU to a Computer
More informationRelease Notes for Cisco IronPort AsyncOS 7.7 for Security Management
Release Notes for Cisco IronPort AsyncOS 7.7 for Security Management Published: February 15, 2012 Revised: April 9, 2012 Contents This document contains information for Cisco IronPort AsyncOS 7.7 for Security
More informationUsing the Web Graphical User Interface
Prerequisites for Using the Web GUI, page 1 Information About Using The Web GUI, page 2 Connecting the Console Port of the Switch, page 3 Logging On to the GUI, page 4 Enabling Web and Secure Web Modes,
More informationForeScout CounterACT. Configuration Guide. Version 4.1
ForeScout CounterACT Network Module: VPN Concentrator Plugin Version 4.1 Table of Contents About the VPN Concentrator Plugin... 3 What to Do... 3 Requirements... 3 CounterACT Requirements... 3 Supported
More informationRAMOS Ultra FW. change log
RAMOS Ultra FW change log 2014 CONTEG, spol. s r.o. All rights reserved. No part of this publication may be used, reproduced, photocopied, transmitted or stored in any retrieval system of any nature, without
More informationTroubleshooting the Network Analysis Module. Netflow Data Export. Web Application CHAPTER
CHAPTER 5 This chapter describes how to troubleshoot the NAM and includes these sections: Netflow Data Export, page 5-1 Error Messages, page 5-9 Web Username and Password Guidelines, page 5-15 Supported
More informationChange History for IBM Switched and Monitored PDU Updated: 03/26/2015
Change History for IBM Switched and Monitored PDU Updated: 03/26/2015 Current Official Potencia PDU Firmware Released Version OPDP_sIBM_v01.3_3 Release Date: 11/20/2014 By Chien-Lung Wu Sr. Software Engineer
More informationVERTIV. Avocent ACS8xxx Advanced Console System Release Notes VERSION 2.4.2, AUGUST 24, Release Notes Section Outline. 1 Update Instructions
VERTIV Avocent ACS8xxx Advanced Console System Release Notes VERSION 2.4.2, AUGUST 24, 2018 Release Notes Section Outline 1 Update Instructions 2 Appliance Firmware Version Information 3 Local Client Requirements
More informationChange History for IBM Switched and Monitored pdu_v01.3_1 5/8/2013
Change History for IBM Switched and Monitored pdu_v01.3_1 5/8/2013 New part numbers, May 2013 IBM released new part numbers for these PDUs. See the table at the bottom for the old and new numbers. The
More informationFrequently Asked Questions (FAQs)
Frequently Asked Questions (FAQs) PowerChute Business Edition v9.5 Frequently Asked Questions Summary PowerChute Business Edition ships with Smart-UPS 5kVA & below. This software provides UPS management,
More informationCyclades ACS 5000 Advanced Console Server Appliances Release Notes Version September 24 th 2010
Cyclades ACS 5000 Advanced Console Server Appliances Release Notes Version 3.3.0-5 September 24 th 2010 This document outlines: 1. Update Instructions 2. Appliance Firmware Version and Language Support
More informationPulse Connect Secure. Network Connect and Windows Secure Access Manager (WSAM) Error Messages. Product Release 8.1
Pulse Connect Secure Network Connect and Windows Secure Access Manager (WSAM) Error Messages Product Release 8.1 Document Revision 1.0 Published: 2015-02-10 2015 by Pulse Secure, LLC. All rights reserved
More informationVersion No. Build Date No./ Release Date. Supported OS Apply to Models New Features/Enhancements. Bugs Fixed/Changes
Build Date / 4.1 Build_17031311 EDR-G903 3.6 Build_16081017 EDR-G903 1. Compliance to IEC 62443-4-2 level 2 requirement. 2. Support for ifadminstatus MIB information as device s port setting. 3. Support
More informationAmigopod Release Notes. Updating to Amigopod Document Overview. Overview of the Update Process. Verify the System s Memory Limit
Amigopod 3.5.4 Release Notes This document contains release information for version 3.5.4 of the Aruba Amigopod visitor management appliance. Document Overview This document is organized into the following
More informationSmart PDU Utility. User Manual
Smart PDU Utility User Manual Table of Contents 1. Introduction... 1 2. Installation... 2 3. Smart PDU Utility Interface... 3 1. Introduction General Smart PDU Utility is advanced PDU monitoring, management
More informationFieldView. Management Suite
FieldView The FieldView Management Suite (FMS) system allows administrators to view the status of remote FieldView System endpoints, create and apply system configurations, and manage and apply remote
More informationInstallation and Operation
Installation and Operation G-Type Rack Power Filter G50NETB2 G50NETB-20A2 120 Vac 15 A 20 A General Information Product Features The APC AV G-Type G50NETB2 and G50NETB-20A2 Rack Power Filters protect high-performance
More informationPower IQ DCIM Monitoring Version 6.2.2
Power IQ DCIM Monitoring Version 6.2.2 These Release Notes contain important information regarding the release of this product, so please read them carefully. We strongly recommend that you read the entire
More informationCS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)
CS-12HDE444C8 (Master) CL-12HDE444C8 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while
More informationRPM30241EV6 RPM30242EV6 (Remote Power Manager) User s Manual
RPM30241EV6 RPM30242EV6 (Remote Power Manager) User s Manual Table of Contents 1. IMPORTANT SAFETY INSTRUCTIONS... 2 2. Introduction... 4 3. RPM Package... 5 4. Function... 6 5. Installation... 8 6. Web
More informationConfiguring Communication Services
This chapter includes the following sections: Configuring HTTP, on page 1 Configuring SSH, on page 2 Configuring XML API, on page 3 Enabling Redfish, on page 3 Configuring IPMI, on page 4 Configuring SNMP,
More informationRuckus Wireless ZoneFlex (ZoneDirector and ZoneFlex Access Points) Release Notes. October 26, 2012
(ZoneDirector and ZoneFlex Access Points) October 26, 2012 Contents 1 Introduction... 3 2 Supported Platforms... 3 3 Upgrading to This Version... 4 3.1 ZoneDirector... 4 Upgrading with Chrome Browser...
More informationUser and System Administration
CHAPTER 2 This chapter provides information about performing user and system administration tasks and generating diagnostic information for obtaining technical assistance. The top-level Admin window displays
More informationMetered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13
Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13 APC Metered Rack PDU, Input: 230V, Input Connections: IEC-320 C14, Cord Length: 10 feet ( 3.05 meters ), Output: 230V, Output Connections:
More informationTable of Contents SMARTZONE G5 USER MANUAL
G5 PDU User Manual 1 Table of Contents Table of Figures... 4 Section 1 System Overview... 7 Intelligent Network Controller... 7 Connecting the PDU to a LAN Ethernet Port... 7 Connecting the PDU to a Computer
More informationConfiguring IP SLAs TCP Connect Operations
This module describes how to configure an IP Service Level Agreements (SLAs) TCP Connect operation to measure the response time taken to perform a TCP Connect operation between a Cisco router and devices
More informationUSER S GUIDE. Contents. InfraStruXure InRow SC. Introduction--1. Control Console--10
Contents Introduction--1 Product Description....................................... 1 Features of the management interface 1 Initial setup 2 Internal Management Features...............................
More informationSoftware Release Notes
Software Release Notes Application System MetroStar SNMP agent MetroStar I Version 1.6.2 Previous version 1.5.0 Version date 22.05.07 1 Added features/components Serial interface (console) alarming support
More informationInstruction Sheet PowerAlert Mass Configuration Utility
Instruction Sheet PowerAlert Mass Configuration Utility Introduction The PowerAlert Mass Configuration Utility enables the configuration of one networked Tripp Lite device to be copied and transferred
More informationFrequently Asked Questions
Q. What is the power metering accuracy on CPI econnect PDUs? A. The power metering accuracy on CPI econnect PDUs is ±1% for each breaker. Meters are included in Monitored, Monitored, Switched and Switched
More informationPDU Utility. User Manual
PDU Utility User Manual Table of Contents 1. Introduction... 1 2. Installation... 2 3. PDU Utility Interface... 4 1. Introduction General PDU Utility is PDU monitoring, management software. It has been
More informationPoseidon 4002 MANUAL
Poseidon 4002 MANUAL Poseidon 4002 MANUAL POWER input 12VDC supply (jack or terminals) INPUTS Binary inputs 1 6 (for contacts) OUTPUTS Two 50V rated switchover relay contacts ETHERNET 10 or 100/10 Mbps
More information