TopSolids Where Expertise meets Convenience

Size: px
Start display at page:

Download "TopSolids Where Expertise meets Convenience"

Transcription

1 TopSolids Where Expertise meets Convenience Dr. Sebastian Wegner Bruker BioSpin, France 30 ème Réunion Utilisateurs Novembre 2016 Innovation with Integrity

2 12/9/ With TopSolids the delicate setup of solid state NMR experiments is made easy by reliable automated procedures whatever your background and experience may be 2 nd generation finally available with TopSpin free of charge compatible with 4 mm and 3.2 mm double and triple channel SB/ WB probes (more to come)

3 12/9/ TopSolids 2.0 News & Updates different modules in flow bar design: New Preparation (incl. advanced user interface to fetch general information in one step, import of former data possible) Probe Setup (not only for general setup, but for e.g. testing a probe after repair, etc.) Bio (incl. setup and optimization, up to 4D 13 C-detected experiments) New Materials (1D/ 2D X, HX CP and MQMAS experiments) modules use an optimum of automation minimized user interactions

4 12/9/ Launching TopSolids execute expinstall for Solid State Systems once open any data set open the Acquire tab in TopSpin (1) pull down the menu item More (2) select TopSolids (3)

5 12/9/ Preparation Module leads back to the Acquire tab the Preparation module opens automatically all flow bars comprise the navigation buttons and an information field to identify the currently used TopSolids module

6 12/9/ Preparation Module New start new user interface if unknown: select the currently installed probe open the new user interface and create your project

7 12/9/ New User Interface for Project Handling simplified creation of a new project TopSolids organizes the data set handling automatically

8 12/9/ New User Interface for Project Handling General Information 1 2 mandatory: fill in directory and sample names select the TopSolids module you want to launch 3

9 12/9/ New User Interface for Project Handling General Information recommended, but not mandatory: load a shim file 4

10 12/9/ New User Interface for Project Handling General Information this might take some seconds 4 5 creates the new directory within the active data path creates a parameter data bank for the new project within this directory loads the respective first data set (dependent on the chosen module) opens the next tab automatically, once finished

11 12/9/ New User Interface for Project Handling Import Previous Data possibility to import a previous TopSolids parameter data bank requirement: New part and serial Nos. of the probe need to match

12 12/9/ New User Interface for Project Handling Import Previous Data click on Import browse to the former TopSolids data set select the file topsolidspars.xml

13 12/9/ New Parameter Handling TopSolids parameter handling is based on: 1. parameter sets 2. PROSOL entries New 3. parameter data bank ensures reasonable values for parameters at any time whether optimized or not yet at the end of any optimization, the determined parameters are stored in the parameter data bank ready for further usage parameters can be reviewed in form of a PDF report at any time, e.g. to assist fast publication

14 12/9/ Probe Setup Module from time to time probe performance needs to be tested though routine work, it can be time consuming even for an NMR expert Probe Setup module offers a high level of convenience to: adjust the magic angle optimize 1 H and 13 C hard pulses on standard samples shim the probe and calibrate spectra with least user interaction to overcome the necessity for extensive prior knowledge only two samples needed: KBr, adamantane

15 12/9/ Probe Setup Module Magic Angle Setting New Magic Angle setting is done on KBr ( 79 Br) at 5 khz MAS TopSolids: checks for fixed frequency H/C/N probes to adjust respective parameter sets automatically New New can detect a Cover Module 2, which can be used for MA adjustment at the spectrometer directly if wanted records a reference spectrum and evaluates the quality of the MA setting

16 12/9/ Probe Setup Module Magic Angle Setting center peak line width = 139 Hz 5 th left SBB line width = 132 Hz

17 12/9/ Probe Setup Module New New probe shimming is done on adamantane at 10 khz MAS automated Z shimming possible (2-5 minutes dependent on starting values) automated B 0 field referencing (towards TMS) in the background shim quality is determined automatically

18 12/9/ Probe Setup Module line width = 4.5 Hz calibrated to ppm (referenced to neat TMS)

19 12/9/ Protein Applications News & Updates whole setup to run multidimensional (nd) experiments on biological sample is divided into three modules: 1. Standard Sample Setup standard sample: [ 13 C, 15 N]-labeled glycine for NCO transfer: any [ 13 C, 15 N]-labeled peptide (e.g. fmlf) or standard protein (SH3, GB1, ubiquitin) 2. Biological Sample Setup (re-) optimize parameters on your sample of interest New optional optimizations: spectral widths, carrier frequencies, 1 H decoupling during acquisition 3. nd Experiments New reverse optimization possible does no longer rely on prior optimization

20 Protein Applications Standard Sample Setup Module cross polarization transfers: optimized hard pulses & the current MAS rate* are used to suggest a suitable Hartmann-Hahn condition * when MAS III unit is used, the rate is detected automatically in the background 12/9/

21 12/9/ Protein Applications Standard Sample Setup Module New

22 12/9/ Protein Applications Biological Sample Setup Module comprises optimizations of all parameters needed for multidimensional experiments available in TopSolids + some optional ones if the Standard Sample Setup module has not been executed before, starting values are taken from PROSOL (+ parameter data bank, if parameters are available)

23 12/9/ Protein Applications Biological Sample Setup Module standard 13 C spectral width complete 13 C region 13 CO region 13 Cα region New the smaller a spectral width in an indirect dimension, the shorter the experimental measurement time of an nd experiment TopSolids can optimize spectral widths & carrier frequencies fully automated - based on CP experiments completely optional!

24 12/9/ Protein Applications nd Experiments Module the flow bar itself did not change from the first generation of TopSolids 2D to 4D experiments for protein backbone assignment and distance measurements

25 12/9/ Protein Applications Reverse Optimization Do I need to go through all these optimizations if I only want to record one specific nd experiment? Which parameters do I need for recording a 3D NCOCx experiment? New Start from scratch & use reverse optimization: select an nd experiment of interest in the nd Experiments module TopSolids automatically detects missing parameters & initiates the respective optimization directly using least user interaction once all parameters have been optimized, it will go back to the nd experiment to support its set up a simplification dedicated especially to unexperienced users

26 12/9/ Protein Applications Reverse Optimization Backbone Assignment 3D NCOCx correlation experiment (CC transfer via PDSD) on biological sample of interest CO-Cx mixing time: 30 ms MAS rate: 10.0 khz number of scans: 48 relaxation rate: 2.0 s acquisition time F3(Cx): ms acquisition time F2 (CO): 5.70 ms acquisition time F1 (N): 5.60 ms number of time domain points F3 (Cx): 2048 number of time domain points F2 (CO): 38 number of time domain points F1 (N): 28 total experimental time: 1 d 5 h 46 min 42 sec experiment in queue experiment finished 3D NCOCx recorded with reverse optimized parameters processing was done fully automated by TopSolids after acquisition was finished New titles include information about acquisition parameters

27 12/9/ TopSolids Material Samples New high demand to implement automation and setup support for applications on material samples TopSolids now provides guided routines to: any X nucleus of choice the mounted probe can handle as for protein applications: optimizations on standard samples and/ or sample of interest for: X hard pulse HX CP 1D/ 2D MQMAS

28 12/9/ Material Applications Standard Sample Setup guides through basic setup routines of 90 degree pulse calibration and CP setup X 90 degree pulse optimization either as a high or a low power pulse, depending on the X nucleus of choice for MQMAS experiments switch to the nd Experiment module, once the 90 degree pulse is known

29 12/9/ Material Applications nd Experiments guides step by step through the setup process to run a 2D MQMAS experiment by optimizing: 1. the minimum spectral width needed as indirect dimension to reduce 2D measurement time

30 12/9/ Material Applications nd Experiments guides step by step through the setup process to run a 2D MQMAS experiment by optimizing: 2. specific MQMAS excitation and reconversion pulse lengths for optimum sensitivity using automated parameter optimization and B 1 excitation field calculations reconversion excitation

31 12/9/ Material Applications nd Experiments TopSolids: guides through the 2D setup step by step takes care that a multiple of the phase cycle is used as number of scans automatically synchronizes the optimized spectral width with the MAS rate applies basic processing and shearing user interaction only needed for entering number of scans and relaxation delay

32 12/9/ TopSolids Summary Simplified user interface Suited for protein and material samples, including quadrupolar nuclei New automation features and minimized user interactions, including basic processing up to 3D s Materials modules include HX CP and MQMAS setup Forward & reverse parameter optimization for protein samples Supports 3.2 and 4 mm double and triple channel probes Extended parameter reporting, including information about nd experiments All multidimensional experiments can be queued basic processing is done as soon as an experiment will have been finished

33 Contact core application people solid-state NMR: Gerhard Althoff (DE) Venita Decker (DE) Sebastian Wegner (DE) Barbara Perrone (CH) Jochem Struppe (US) Fabien Aussenac for solids DNP + all the other application people world wide! important s: solids@bruker.com

34

35 Revisiting a former TopSolids Project open a previous TopSolids data set and start TopSolids 12/9/

Modern Solid State NMR. Stefan Steuernagel Bruker BioSpin GmbH, Germany BeNeLux Users Meeting, Brussels November 25, 2016

Modern Solid State NMR. Stefan Steuernagel Bruker BioSpin GmbH, Germany BeNeLux Users Meeting, Brussels November 25, 2016 Modern Solid State NMR Stefan Steuernagel Bruker BioSpin GmbH, Germany BeNeLux Users Meeting, Brussels November 25, 2016 Modern Solid State NMR Solid state DNP NMR 111 khz MAS with 0.7mm probe TopSolids

More information

Statut actuel de NUS et APSY

Statut actuel de NUS et APSY Statut actuel de NUS et APSY Martial PIOTTO Bruker BioSpin, France 30 ème Réunion Utilisateurs 29-30 Novembre 2016 Innovation with Integrity General features of NUS and APSY Techniques that allow to collect

More information

Supplementary Material

Supplementary Material Supplementary Material Sugar-to-base correlation in nucleic acids with a 5D APSY-HCNCH or two 3D APSY-HCN experiments Barbara Krähenbühl Daniela Hofmann Christophe Maris Gerhard Wider Institute of Molecular

More information

AVANCE IVDr. IVDr Data Browser User Manual. Innovation with Integrity. Version 001 NMR

AVANCE IVDr. IVDr Data Browser User Manual. Innovation with Integrity. Version 001 NMR AVANCE IVDr IVDr Data Browser User Manual Version 001 Innovation with Integrity NMR Copyright by Bruker Corporation All rights reserved. No part of this publication may be reproduced, stored in a retrieval

More information

Vanderbilt Small Molecule NMR Center

Vanderbilt Small Molecule NMR Center Vanderbilt Small Molecule NMR Center Instructions for Using TOPSPIN version 2.0 DRX 400: Setting up 1H, 13C (1H decoupled), and 31P NMR Experiments Getting started: Sample Preparation: Make sure your sample

More information

VNMRJ 4.2 INSTRUCTIONS: QANUC 500 FOR CHEMISTS

VNMRJ 4.2 INSTRUCTIONS: QANUC 500 FOR CHEMISTS VNMRJ 4.2 INSTRUCTIONS: QANUC 500 FOR CHEMISTS April 16, 2018 1. Sample preparation a. Tubes of any length can be used b. Make your samples 4 cm deep. They will not shim as well if they are shorter; you

More information

Diffusion Ordered Spectroscopy (DOSY) Overview BRUKER last edit 5/14/12

Diffusion Ordered Spectroscopy (DOSY) Overview BRUKER last edit 5/14/12 Diffusion Ordered Spectroscopy (DOSY) Overview BRUKER last edit 5/14/12 DOSY Diffusion Ordered SpectroscopY. NMR diffusion experiments, like DOSY, are used to determine the diffusion coefficients of solute

More information

NMR Spectroscopy with VnmrJ. University of Toronto, Department of Chemistry

NMR Spectroscopy with VnmrJ. University of Toronto, Department of Chemistry NMR Spectroscopy with VnmrJ University of Toronto, Department of Chemistry Walk-up interface 1 Logging in 1 Starting VnmrJ 1 Inserting sample into the magnet or sample changer 1 Enter sample information

More information

PINMRF. Bruker AV-III / Avance DRX NMR Spectrometers running TopSpin Training Supplement for Advanced 1D NMR Spectroscopy

PINMRF. Bruker AV-III / Avance DRX NMR Spectrometers running TopSpin Training Supplement for Advanced 1D NMR Spectroscopy PINMRF Bruker AV-III / Avance DRX NMR Spectrometers running TopSpin Training Supplement for Advanced 1D NMR Spectroscopy INCLUDING: AV-III-400-HD w/ 5mm BBFO SmartProbe 369 WTHR AV-III-500-HD w/ 5mm BBFO

More information

VNMRJ 4.2 INSTRUCTIONS: VARIAN MERCURY 400 AND VARIAN VNMRS 500

VNMRJ 4.2 INSTRUCTIONS: VARIAN MERCURY 400 AND VARIAN VNMRS 500 VNMRJ 4.2 INSTRUCTIONS: VARIAN MERCURY 400 AND VARIAN VNMRS 500 August 9, 2016 1. Sample preparation a. Tubes of any length can be used b. Make your samples 4 cm deep. They will not shim as well if they

More information

KJM Proton T1 Spectra on the AVI-600 and AVII-600. Version 1.0

KJM Proton T1 Spectra on the AVI-600 and AVII-600. Version 1.0 KJM 9250 Proton T1 Spectra on the AVI-600 and AVII-600 Version 1.0 Professor Emeritus Alistair Lawrence Wilkins, University of Waikato, New Zealand. February 2018 Proton T1 Spectra on the AVI-600 and AVII-600

More information

TopSpin QuickStart. Default State TopSpin should be running at all times. If this is not the case, you may need to Log In and Start TopSpin.

TopSpin QuickStart. Default State TopSpin should be running at all times. If this is not the case, you may need to Log In and Start TopSpin. TopSpin QuickStart Preliminaries Sign Up Sign up for instrument time at calendar.yahoo.com/hmcnmr The password is nmr. During the summer, 1100-1200 and 1600-1700 are reserved for walk-on use (15 min maximum

More information

VnmrJ 3.2: Industry-Leading Software for NMR Spectrometers

VnmrJ 3.2: Industry-Leading Software for NMR Spectrometers VnmrJ 3.2: Industry-Leading Software for NMR Spectrometers Key Benefits: Full integration of ChemPack Integration of NMR Pipe Availability of DataStation version A new, simplified sample-centric workflow

More information

VNMRJ 4.2 INSTRUCTIONS: VARIAN MERCURY 400

VNMRJ 4.2 INSTRUCTIONS: VARIAN MERCURY 400 VNMRJ 4.2 INSTRUCTIONS: VARIAN MERCURY 400 January 10, 2019 1. Sample preparation a. Tubes of any length can be used b. Make your samples 4 cm deep. They will not shim as well if they are shorter; you

More information

Quick Guide to Topspin

Quick Guide to Topspin Quick Guide to Topspin 1. Log into the workstation. Right mouse click on the desktop anywhere and select new terminal. Type topspin [enter] (if this fails, create the launcher as described next). Alternatively,

More information

IconNMR Operating Procedures

IconNMR Operating Procedures IconNMR Operating Procedures Revised: 7-1-2015 This guide provides basic instructions for acquiring NMR spectra using the IconNMR automation program. 1. Insert your sample(s) in the SampleXpress sample

More information

Walkup NMR. Varian NMR Spectrometer Systems With VNMR 6.1C Software. Pub. No , Rev. A0800

Walkup NMR. Varian NMR Spectrometer Systems With VNMR 6.1C Software. Pub. No , Rev. A0800 Walkup NMR Varian NMR Spectrometer Systems With VNMR 6.1C Software Pub. No. 01-999159-00, Rev. A0800 Walkup NMR Varian NMR Spectrometer Systems With VNMR 6.1C Software Pub. No. 01-999159-00, Rev. A0800

More information

Bruker Avance 400 MHz Instructions

Bruker Avance 400 MHz Instructions Bruker Avance 400 MHz Instructions General Policy: 1) All users must pass the training course before they will obtain their own access to the spectrometer. 2) A key to Bruker Avance 400 Room is accessible

More information

Brief IconNMR and Topspin 3.5 User Guide for Bruker NMR Spectrometers Avance IIIHD 400MHz NMR with Autosampler in Chemistry room 93 DISCLAIMER

Brief IconNMR and Topspin 3.5 User Guide for Bruker NMR Spectrometers Avance IIIHD 400MHz NMR with Autosampler in Chemistry room 93 DISCLAIMER DISCLAIMER Brief IconNMR and Topspin 3.5 User Guide for Bruker NMR Spectrometers Avance IIIHD 400MHz NMR with Autosampler in Chemistry room 93 This document is intended to be a brief, bare-bones user s

More information

Vnmrj 3.1 New and improved features

Vnmrj 3.1 New and improved features Vnmrj 3.1 New and improved features Automation& Hardware Printing USB printers are supported. Using CUPS, a generic print dialog and JPG, PDF, & other formats have replaced the previous method of sending

More information

VNMRJ 2.1B Quick overview and BioPack features

VNMRJ 2.1B Quick overview and BioPack features VNMRJ 2.1B Quick overview and BioPack features VNMRJ 2.1B interface is a much more intuitive user interface than the VNMR6.1C. The Java interface is a layer on top of the conventional VNMR so all commands

More information

Short instructions for the basic operation of the AVANCE II 400 MHz Bruker NMR Using ICON-NMR (PS751)

Short instructions for the basic operation of the AVANCE II 400 MHz Bruker NMR Using ICON-NMR (PS751) Dissimilar This manual is intended to be only a very brief introduction for using the Bruker 400 MHz NMR spectrometer (PS751) at the California State University LA NMR Facility. For complete information

More information

NMR Spectrometer Crib-Sheet

NMR Spectrometer Crib-Sheet NMR Spectrometer Crib-Sheet Sample Preparation: 1. Dissolve your sample in a deuterated solvent. For 1 H NMR use ~ 1 mm concentrations. For 13 C NMR, use ~ 10 mm. 2. Use clean dry tubes to avoid contaminating

More information

c. Saturday and Sunday: 10 minute time blocks and unlimited time.

c. Saturday and Sunday: 10 minute time blocks and unlimited time. Scheduling 400 MHz A with 100 slot sample changer: a. Monday to Friday from 8 am to 8 pm: 10 minute blocks, 30min max. b. Monday to Friday from 8 pm to 8 am: 10 minute blocks, unlimited time. c. Saturday

More information

QuiC 1.0 (Owens) User Manual

QuiC 1.0 (Owens) User Manual QuiC 1.0 (Owens) User Manual 1 Contents 2 General Information... 2 2.1 Computer System Requirements... 2 2.2 Scope of QuiCSoftware... 3 2.3 QuiC... 3 2.4 QuiC Release Features... 3 2.4.1 QuiC 1.0... 3

More information

Processing data with Bruker TopSpin

Processing data with Bruker TopSpin Processing data with Bruker TopSpin This exercise has three parts: a 1D 1 H spectrum to baseline correct, integrate, peak-pick, and plot; a 2D spectrum to plot with a 1 H spectrum as a projection; and

More information

NUS: non-uniform sampling

NUS: non-uniform sampling FMP, 10.10.2012 2/48 NMR-spectroscopy uses the nuclear spin that can be thought of as a mixture between gyroscope and magnet 3/48 The frequency of the rotation of the spin in a magnetic field is what we

More information

TOCSY 15. Goto. Introduction Pulse Sequence Diagram AVANCE User s Guide Bruker 167

TOCSY 15. Goto. Introduction Pulse Sequence Diagram AVANCE User s Guide Bruker 167 Chapter TOCSY 15 Introduction 15.1 Goto TOtal Correlation SpectroscopY provides a different mechanism of coherence transfer than COSY for 2D correlation spectroscopy in liquids. In TOCSY, cross peaks are

More information

Acquiring Data in VnmrJ 4.2A

Acquiring Data in VnmrJ 4.2A Acquiring Data in VnmrJ 4.2A Linux Primer Initial Steps Changing Password Disabling Screen Lock Reservations Reservation Terminals Rules and Proper Etiquette System Identification Working with VnmrJ 4.2A

More information

PROCESSING 2D SPECTRA USING VNMRJ JB Stothers NMR Facility Materials Science Addition 0216 Department of Chemistry Western University

PROCESSING 2D SPECTRA USING VNMRJ JB Stothers NMR Facility Materials Science Addition 0216 Department of Chemistry Western University PROCESSING 2D SPECTRA USING VNMRJ JB Stothers NMR Facility Materials Science Addition 0216 Department of Chemistry Western University 1. INTRODUCTION...1 1.1. About this Worksheet... 1 1.2. A Very Brief

More information

1D and 2D Experiments Step-by-Step Tutorial

1D and 2D Experiments Step-by-Step Tutorial 1D and 2D Experiments Step-by-Step Tutorial Basic Experiments User Guide Version 004 The information in this manual may be altered without notice. BRUKER BIOSPIN accepts no responsibility for actions taken

More information

Routine 1 H and 13 C NMR Data Acquisition Basic Topspin Processing Guide For PSC and NSC Bruker 400 NMR Spectrometer

Routine 1 H and 13 C NMR Data Acquisition Basic Topspin Processing Guide For PSC and NSC Bruker 400 NMR Spectrometer Routine 1 H and 13 C NMR Data Acquisition Basic Topspin Processing Guide For PSC and NSC Bruker 400 NMR Spectrometer Dr. Zhenming Du Email: zdu@gsu.edu Phone: 3-5538 Revised 04/02/2015 LC=Left click; DC=double

More information

General Information for Automated Inova 500 MHz NMR (Indy)

General Information for Automated Inova 500 MHz NMR (Indy) General Information for Automated Inova 500 MHz NMR (Indy) Primary Contacts: NMR Facility Manager: David VanderVelde, x3004, davidv@caltech.edu GLA: Pamela Tadross, x6131, 646-220-5789 (cell), 204 Church,

More information

HIFI NMR : part1 automated backbone assignments using 3D->2D

HIFI NMR : part1 automated backbone assignments using 3D->2D HIFI NMR : part automated backbone assignments using 3D->2D Marco Tonelli National Magnetic Resonance Facility At Madison NMRFAM Recording multidimensional experiments is time costly In conventional multidimensional

More information

DCIF NMR Training Guide 400 MHz Bruker AVANCE III HD b400 last edit 3/9/2015

DCIF NMR Training Guide 400 MHz Bruker AVANCE III HD b400 last edit 3/9/2015 DCIF NMR Training Guide 400 MHz Bruker AVANCE III HD b400 last edit 3/9/2015 The Bruker AVANCE III HD 400 has a broadband (BBO) probe with a 1 H Channel and X-Channel tunable from (30-300 MHz). Both channels

More information

UC DAVIS NMR FACILITY BRUKER SHORT MANUAL FOR TOPSPIN 3.X

UC DAVIS NMR FACILITY BRUKER SHORT MANUAL FOR TOPSPIN 3.X TABLE OF CONTENTS UC DAVIS NMR FACILITY BRUKER SHORT MANUAL FOR TOPSPIN 3.X VERSION 3 February, 2016 Disclaimer... 2 Conventions... 2 Routine 1D NMR Experiments Procedure for acquiring 1D Proton spectrum...

More information

BioPack. User Guide. Agilent Technologies

BioPack. User Guide. Agilent Technologies BioPack User Guide Agilent Technologies Notices Agilent Technologies, Inc. 2010 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation

More information

IconNMR (>TopSpin 3.0)

IconNMR (>TopSpin 3.0) IconNMR (>TopSpin 3.0) Dr. Sven Augner Bruker BioSpin, Rheinstetten, Germany Innovation with Integrity How to start an IconNMR set 2 IconNMR Select the respective holder 2x IconNMR Select the disk Base

More information

NMR Data Acquisition and Processing Procedure

NMR Data Acquisition and Processing Procedure NMR Data Acquisition and Processing Procedure Dr. Jianfeng Zhu (Research Officer) Please DO NOT remove from NMR lab! Things to Avoid when Using NMR Lab Here's a list of stuff that I have seen that you

More information

15. HOMONUCLEAR COSY

15. HOMONUCLEAR COSY Homonuclear COSY Page 67 15. HOMONUCLEAR COSY by cg fry: created 12/27/94 updated 11/26/00 In COrrelational SpectroscopY (COSY), a fast 2D spectrum is usually obtained first. This initial set of data takes

More information

DCIF NMR Training Guide 400 MHz Bruker DRX B401 Bruker DPX B400

DCIF NMR Training Guide 400 MHz Bruker DRX B401 Bruker DPX B400 1 DCIF NMR Training Guide 400 MHz Bruker DRX B401 Bruker DPX B400 400: The Bruker DPX 400 has a broadband probe with 1 H Channel and X-Channel tunable from (30-300 MHz). Both Channels may be tuned researchers.

More information

Bruker AVANCE III HD 400 MHz Spectrometer Operation

Bruker AVANCE III HD 400 MHz Spectrometer Operation Bruker AVANCE III HD 400 MHz Spectrometer Operation The spectrometer is located in Room 312 of Physical Sciences I. It is equipped with a SampleXpress sample changer for full automation. To utilize the

More information

See XwinNMR Acquisition Manual, Sections 1.4, 1.5 (see list of acquistion parameter descriptions starting , pg. A-39), 1.6

See XwinNMR Acquisition Manual, Sections 1.4, 1.5 (see list of acquistion parameter descriptions starting , pg. A-39), 1.6 Bruker Avance360 X-Nucleus Experiments Page 13 III. X-Nucleus Acquisitions Example Session See XwinNMR Acquisition Manual, Sections 1.4, 1.5 (see list of acquistion parameter descriptions starting 1.5.2.4,

More information

2 Dimensional NMR User s Brief Guide

2 Dimensional NMR User s Brief Guide 2D NMR Handout 7/17/18 Weiguo Hu 2 Dimensional NMR User s Brief Guide (This handout presumes your thorough familiarity with the 1D handout commands and their use!) Options There are a vast number of 2D

More information

FOCUS. Image Based Automatic Shimming Using B 0 Gradients. Installation and Users Guide Version 0.9

FOCUS. Image Based Automatic Shimming Using B 0 Gradients. Installation and Users Guide Version 0.9 FOCUS Image Based Automatic Shimming Using B 0 Gradients Installation and Users Guide Version 0.9 FOCUS - Field Optimization by Computed Update of Shims Joost A. B. Lohman, Bruker Spectrospin ltd, U.K.

More information

From FID to 2D: Processing HSQC Data Using NMRPipe Macro Methods

From FID to 2D: Processing HSQC Data Using NMRPipe Macro Methods The data recorded during a NMR experiment are stored in the form of a digitized free induction decay (FID), which is in the time domain. In order for us to gain information regarding the chemical environment

More information

ChromQuest 5.0 Quick Reference Guide

ChromQuest 5.0 Quick Reference Guide ChromQuest 5.0 Quick Reference Guide This guide contains an overview of the ChromQuest chromatography data system, with topics organized by workflow. For more information, refer to the ChromQuest User

More information

T 1 Relaxation Measurement: The Inversion-Recovery Experiment (Using IconNMR) Revised

T 1 Relaxation Measurement: The Inversion-Recovery Experiment (Using IconNMR) Revised T 1 Relaxation Measurement: The Inversion-Recovery Experiment (Using IconNMR) Revised 4-21-2015 Relaxation times are divided into two types: longitudinal, which concerns change in magnetization along the

More information

NMR INSTRUMENT INSTRUCTIONS: Safety and Sample Preparation

NMR INSTRUMENT INSTRUCTIONS: Safety and Sample Preparation NMR INSTRUMENT INSTRUCTIONS: Safety and Sample Preparation The GVSU chemistry department owns 2 NMR spectrometers. A JEOL Eclipse 300 MHz and a Varian Inova 400 MHz. Due to their strong, constant magnetic

More information

1D NMR Training Manual for Operating the Bruker 700 MHz Avance III HD NMR. Spectrometer without the Sample Changer and IconNMR

1D NMR Training Manual for Operating the Bruker 700 MHz Avance III HD NMR. Spectrometer without the Sample Changer and IconNMR 1D NMR Training Manual for Operating the Bruker 700 MHz Avance III HD NMR Spectrometer without the Sample Changer and IconNMR Scheduling NMR Time: Any use of the 700 MHz NMR spectrometer requires prior

More information

MNova Version Installation Instructions.

MNova Version Installation Instructions. MNova Version 12.0.0 Installation Instructions. Note: This Document contains information for a new NMR user. Carefully read and accomplish each section before moving to the next. If you can t finish a

More information

Galaxie Photodiode Array Software

Galaxie Photodiode Array Software Varian, Inc. 2700 Mitchell Drive Walnut Creek, CA 94598-1675/USA Galaxie Photodiode Array Software User s Guide Varian, Inc. 2002-2006 03-914950-00:6 Table of Contents Introduction... 3 General... 3 PDA

More information

Protein Deconvolution Quick Start Guide

Protein Deconvolution Quick Start Guide Protein Deconvolution Quick Start Guide The electrospray ionization (ESI) of intact peptides and proteins produces mass spectra containing a series of multiply charged ions with associated mass-to-charge

More information

B ACS 60/120. Sample Down Unit Installation Guide. Innovation with Integrity. Version 001 NMR

B ACS 60/120. Sample Down Unit Installation Guide. Innovation with Integrity. Version 001 NMR B ACS 60/120 Sample Down Unit Installation Guide Version 001 Innovation with Integrity NMR The information in this manual may be altered without notice. BRUKER BIOSPIN accepts no responsibility for actions

More information

Agilent VnmrJ 3.2. Quick Start Guide

Agilent VnmrJ 3.2. Quick Start Guide Agilent VnmrJ 3.2 Quick Start Guide VnmrJ 3.2 Interface 3 Overview 4 Prepare Sample 5 Load Sample 6 Enter Sample Information 7 Build Study Queue 8 Run Study Queue 8 Process Data 9 Plot Data 10 This Quick

More information

ComingSoon FulNMRCatalog visitwilmad.com todownload

ComingSoon FulNMRCatalog visitwilmad.com todownload ComingSoon FulNMRCatalog visitwilmad.com todownload Wilmad 5mm OD Thin Walled Economy NMR Tubes Economy Designed for routine use in modern NMR spectrometers, Wilmad Economy NMR Tubes are guaranteed to

More information

Varian Solution NMR Automation Procedure

Varian Solution NMR Automation Procedure Menu System System Tool Bar Command Line Graphics Tool Bar Vertical Panels Protocols NMR Data Display NMR Graphics Area Study Queue Horizontal Panels Activity Monitoring Varian Solution NMR Automation

More information

Single-sided Magnet Diffusion Measurements

Single-sided Magnet Diffusion Measurements Single-sided Magnet Diffusion Measurements Kuldeep S. Panesar April 2013 (kuldeep.panesar@gmail.com) Contents 1. Initial configuration... 2 2. Preparation for diffusion measurement... 5 3. Starting a diffusion

More information

DCIF NMR Training Guide 401 MHz Bruker AVANCE III HD b401 last edit 3/11/2015

DCIF NMR Training Guide 401 MHz Bruker AVANCE III HD b401 last edit 3/11/2015 DCIF NMR Training Guide 401 MHz Bruker AVANCE III HD b401 last edit 3/11/2015 The Bruker AVANCE III HD 401 has a broadband (BBO) probe with a 1 H Channel and X-Channel tunable from (30-300 MHz). Both channels

More information

2013 Copyright Brüel & Kjær. All rights reserved

2013 Copyright Brüel & Kjær. All rights reserved ONOSCOUT SETUP GUIDE 2013 Copyright Brüel & Kjær. All rights reserved Sonoscout is an intuitive mobile device app * that combines with a wireless data acquisition unit to form a complete and highly portable

More information

Bruker NMR Topspin Manual

Bruker NMR Topspin Manual Bruker NMR Topspin Manual Topspin is an icon driven software package. This means that instead of reading words and typing commands in the software most of the things will be carried out by clicking icons

More information

PiSpec Software & Digital Pulse Processors

PiSpec Software & Digital Pulse Processors PiSpec Software & Digital Pulse Processors PiSpec software is designed to control several optional Digital Pulse Processors (DPP) for spectral data acquisition. The optional DPPs include XIA DXP-MERCURY,

More information

500 MHz Solution-state NMR Procedure. (Bruker AVANCE Machines running TopSpin under WINDOWS XP)

500 MHz Solution-state NMR Procedure. (Bruker AVANCE Machines running TopSpin under WINDOWS XP) 500 MHz Solution-state NMR Procedure (Bruker AVANCE Machines running TopSpin under WINDOWS XP) Jerry Hu, x7914, jghu@mrl.ucsb.edu Shamon Walker, x6079 shamonwalker@mrl.ucsb.edu Materials Research Laboratory

More information

500 MHz Solution-state NMR Procedure. (Bruker AVANCE Machines running TopSpin under WINDOWS XP)

500 MHz Solution-state NMR Procedure. (Bruker AVANCE Machines running TopSpin under WINDOWS XP) 500 MHz Solution-state NMR Procedure (Bruker AVANCE Machines running TopSpin under WINDOWS XP) Jerry Hu, x7914, jghu@mrl.ucsb.edu Shamon Walker, x3248 shamonwalker@mrl.ucsb.edu Materials Research Laboratory

More information

UC DAVIS NMR FACILITY VNMRJ SHORT MANUAL FOR VARIAN/AGILENT NMR SPECTROMETERS

UC DAVIS NMR FACILITY VNMRJ SHORT MANUAL FOR VARIAN/AGILENT NMR SPECTROMETERS UC DAVIS NMR FACILITY VNMRJ SHORT MANUAL FOR VARIAN/AGILENT NMR SPECTROMETERS TABLE OF CONTENTS Disclaimer... 2 Conventions... 2 Routine 1D NMR Experiments Procedure for acquiring 1D Proton spectrum...

More information

Wilmad Your One Stop NMR Shop

Wilmad Your One Stop NMR Shop Wilmad Your One Stop NMR Shop 100% Tested Precision Tools Because Nothing is More Important Than Your Results Prepare to Discover Wilmad 5mm OD Thin Walled Economy NMR Tubes Economy Designed for routine

More information

Dynamics Center. User Manual. Innovation with Integrity. Version 002 NMR

Dynamics Center. User Manual. Innovation with Integrity. Version 002 NMR Dynamics Center User Manual Version 002 Innovation with Integrity NMR Copyright by Bruker Corporation All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or

More information

Bruker Topspin NMR Training Manual

Bruker Topspin NMR Training Manual Bruker Topspin NMR Training Manual Rev 180521 Perry Pellechia University of South Carolina NMR Facility Subject Page Number Overview of Operation... 1 Gauging Samples in Spinners... 2 Starting and logging

More information

Intro to 2D NMR: Homonuclear correlation COSY, lr-cosy, and DQ-COSY experiments

Intro to 2D NMR: Homonuclear correlation COSY, lr-cosy, and DQ-COSY experiments Homework 9 Chem 636, Spring 2014 due at the beginning of lab April 8-10 updated 8 Apr 2014 (cgf) Intro to 2D NMR: Homonuclear correlation COS, lr-cos, and DQ-COS experiments Use Artemis (Av-400) or Callisto

More information

Statistical Process Control in Proteomics SProCoP

Statistical Process Control in Proteomics SProCoP Statistical Process Control in Proteomics SProCoP This tutorial will guide you through the installation of SProCoP and using it to perform statistical analysis on a sample Skyline file. Getting Started

More information

Varian Solution NMR Automation Procedure (VNMRS Machines running VNMRJ 4.2 under Red Hat Enterprise 5.1)

Varian Solution NMR Automation Procedure (VNMRS Machines running VNMRJ 4.2 under Red Hat Enterprise 5.1) Menu System System Tool Bar Command Line Graphics Tool Bar Vertical Panels Protocols NMR Data Display NMR Graphics Area Study Queue Horizontal Panels Activity Monitoring Varian Solution NMR Automation

More information

SIRIUS 200 U1X200A SRS U1X200A SRS USER S MANUAL

SIRIUS 200 U1X200A SRS U1X200A SRS USER S MANUAL SIRIUS 200 U1X200A12-310-SRS U1X200A24-310-SRS USER S MANUAL Belgrade, March 2005 CONTENTS 1 GENERAL 1.1. IMPORTANT NOTICES 2 TECHNICAL SPECIFICATIONS 2.1. INPUT (MAINS) 2.2. OUTPUT 2.3. ENVIROMENTAL CONDITIONS

More information

QUANTAX EDS SYSTEM SOP

QUANTAX EDS SYSTEM SOP QUANTAX EDS SYSTEM SOP December 2017 Energy-Dispersive X-Ray Spectroscopy (EDS, EDX, EDXS or XEDS), is an analytical technique used for the elemental analysis or chemical characterization of a sample.

More information

On Artemis and Cronus, make sure you are adjusting the db scale and not the watts

On Artemis and Cronus, make sure you are adjusting the db scale and not the watts Solvent Suppression - Presaturation (NOTE: There are many types of solvent suppression this is presaturation and all exchangeable protons will be attenuated-instructions for other types follow) 1. Turn

More information

Thermometer T12. Precision Multichannel Thermometer System. Typical applications: REFLECTING YOUR STANDARDS

Thermometer T12. Precision Multichannel Thermometer System. Typical applications: REFLECTING YOUR STANDARDS Precision Multichannel Thermometer System Twelve channel temperature measurement High precision, stability and repeatability Internal reference resistors PC software for system control and data acquisition

More information

deco - A decomposition program for NMR projection experiments JONAS FREDRIKSSON Master of Science Thesis in the computer science program F 1 (ω 1 )

deco - A decomposition program for NMR projection experiments JONAS FREDRIKSSON Master of Science Thesis in the computer science program F 1 (ω 1 ) ! ω 1 # ω# ω 2 # F 1 (ω 1 ) F 2 (ω 2 ) F 3 (ω 3 ) 3 120.490 N 3 8.810 HN 3 58.230 CA 3 5.070 HA 3 42.960 CB ω HN # deco - A decomposition program for NMR projection experiments Master of Science Thesis

More information

Panorama Sharing Skyline Documents

Panorama Sharing Skyline Documents Panorama Sharing Skyline Documents Panorama is a freely available, open-source web server database application for targeted proteomics assays that integrates into a Skyline proteomics workflow. It has

More information

Running Multiple Experiments on the Same Sample Automatically. (multizg, spooler/queue, iconnmr)

Running Multiple Experiments on the Same Sample Automatically. (multizg, spooler/queue, iconnmr) Running Multiple Experiments on the Same Sample Automatically (multizg, spooler/queue, iconnmr) Multiple Experiment Setup If you have one sample that requires full characterization (e.g. 1 H, 13 C, COSY,

More information

UNIFIT - Spectrum Processing, Peak Fitting, Analysis and Presentation Software for XPS, AES, XAS and RAMAN Spectroscopy Based on WINDOWS

UNIFIT - Spectrum Processing, Peak Fitting, Analysis and Presentation Software for XPS, AES, XAS and RAMAN Spectroscopy Based on WINDOWS UNIFIT - Spectrum Processing, Peak Fitting, Analysis and Presentation Software for XPS, AES, XAS and RAMAN Spectroscopy Based on WINDOWS UNIFIT FOR WINDOWS is an universal processing, analysis and presentation

More information

Eft Spectrometer Guides

Eft Spectrometer Guides Eft Spectrometer Guides Anasazi Instruments, Inc. 4101 Cashard Ave. Suite 103 Indianapolis, IN 46203 Tel: 317-783-4126 866-494-9369 (Toll Free) Fax: 317-783-7083 Email: aiinmr@aol.com PN 000103-000 Rev.

More information

Agilent VnmrJ 3.2 Automation

Agilent VnmrJ 3.2 Automation Agilent VnmrJ 3.2 Automation User Guide Agilent Technologies Notices Agilent Technologies, Inc. 2011 No part of this manual may be reproduced in any form or by any means (including electronic storage and

More information

Tutorial 2: Analysis of DIA/SWATH data in Skyline

Tutorial 2: Analysis of DIA/SWATH data in Skyline Tutorial 2: Analysis of DIA/SWATH data in Skyline In this tutorial we will learn how to use Skyline to perform targeted post-acquisition analysis for peptide and inferred protein detection and quantification.

More information

Rat 2D EPSI Dual Band Variable Flip Angle 13 C Dynamic Spectroscopy

Rat 2D EPSI Dual Band Variable Flip Angle 13 C Dynamic Spectroscopy Rat 2D EPSI Dual Band Variable Flip Angle 13 C Dynamic Spectroscopy In this example you will load a dynamic MRS animal data set acquired on a GE 3T scanner. This data was acquired with an EPSI sequence

More information

External Triggering Options

External Triggering Options 380 Main Street Dunedin, FL 34698 (727) 733-2447 (727) 733-3962 fax External Triggering Options Our S2000 and S1024DW Spectrometers provide four methods of acquiring data. In the Normal Mode, Ocean Optics

More information

3-D Gradient Shimming

3-D Gradient Shimming 3-D Gradient Shimming 3-D Gradient Shimming on imaging and micro-imaging systems Technical Overview Introduction Advantage statement The GE3DSHIM method is a 3-D gradient shimming procedure developed for

More information

PINMRF. Bruker Avance / AV NMR Spectrometers running TopSpin Training Supplement for Advanced 1D NMR Spectroscopy

PINMRF. Bruker Avance / AV NMR Spectrometers running TopSpin Training Supplement for Advanced 1D NMR Spectroscopy PINMRF Bruker Avance / AV NMR Spectrometers running TopSpin Training Supplement for Advanced 1D NMR Spectroscopy INCLUDING: Avance DRX500-1 w/ 5mm TBI Probe - 367 WTHR Avance DRX500-2 w/ 5mm BBO or TXI

More information

CONNJUR Workflow Builder: Tutorial. Where to download:

CONNJUR Workflow Builder: Tutorial. Where to download: CONNJUR Workflow Builder: Tutorial Part I: Introduction 1.1 About CONNJUR and CONNJUR Workflow Builder (CWB) The CONNJUR Project is to develop an open source integration environment for biomolecular NMR

More information

2017 Bruker BioSpin Users Meeting IconNMR Update

2017 Bruker BioSpin Users Meeting IconNMR Update Innovation with Integrity 2017 Bruker BioSpin Users Meeting IconNMR Update Mark Garvey R&D Software Bruker BioSpin GmbH Hannover 6.-7. November & München 8.-9. November 2017 Welcome IconNMR Update IconWEB

More information

Fluorimeter User s Booklet

Fluorimeter User s Booklet Fluorimeter User s Booklet 1) Verify that the instrument power and the computer are both off. Then turn on the lamp. The red indicator light will glow when the lamp is on. Turn on lamp switch here. This

More information

Software opmaak.indd :32:15

Software opmaak.indd :32:15 Software Dynamic Linking Library (DLL) Interface packages AS-161-Linux drivers for AvaSpec USB1 platform spectrometers A special set of designated Linux drivers for the AvaSpec USB1 platform

More information

UHD 185 FAQs. Optical System

UHD 185 FAQs. Optical System UHD 185 FAQs System Setup How is a typical setup of the UHD 185? Is a wireless control during flight possible? How do I trigger the image acquisition? What is the power consumption? What are the specs

More information

Evex NanoAnalysis EDS Acquisition

Evex NanoAnalysis EDS Acquisition NanoAnalysis EDS Acquisition 1. Proper Kv for the sample 2. Correct working distance for EDS 3. Good Image correct magnification & in focus 4. Make note if sample is tilted 5. Adjust beam current for proper

More information

CONTENTS 1D EXPERIMENTS D EXPERIMENTS APPENDIXES... 83

CONTENTS 1D EXPERIMENTS D EXPERIMENTS APPENDIXES... 83 Jari Koivisto, Ph.D. Aalto University School of Science and Technology Faculty of Chemistry and Materials Sciences Department of Chemistry Bruker Avance DPX400 User Manual Basic and Advanced 1D and 2D

More information

Bruker. SDD X-ray Detector

Bruker. SDD X-ray Detector Operating Manual Part 2 Bruker SDD X-ray Detector Contacts Cornell Police: 255-5111 Emergency: 911 Phil Carubia: 255-6757 8.00 Step 1 - setup: Select Objects and click on MultiPoint MultiPoint Mode Set

More information

This manual describes step-by-step instructions to perform basic operations for data analysis.

This manual describes step-by-step instructions to perform basic operations for data analysis. HDXanalyzer User Manual The program HDXanalyzer is available for the analysis of the deuterium exchange mass spectrometry data obtained on high-resolution mass spectrometers. Currently, the program is

More information

PROTEOMIC COMMAND LINE SOLUTION. Linux User Guide December, B i. Bioinformatics Solutions Inc.

PROTEOMIC COMMAND LINE SOLUTION. Linux User Guide December, B i. Bioinformatics Solutions Inc. >_ PROTEOMIC COMMAND LINE SOLUTION Linux User Guide December, 2015 B i Bioinformatics Solutions Inc. www.bioinfor.com 1. Introduction Liquid chromatography-tandem mass spectrometry (LC-MS/MS) based proteomics

More information

North Carolina State University Department of Chemistry Varian NMR Training Manual

North Carolina State University Department of Chemistry Varian NMR Training Manual North Carolina State University Department of Chemistry Varian NMR Training Manual by J.B. Clark IV & Dr. S. Sankar 1 st Edition 05/15/2009 Section 1: Essential Operations for Basic 1D Spectra Preparing

More information

EMBED2000+ Data Sheet

EMBED2000+ Data Sheet EMBED2000+ Data Sheet Description The Ocean Optics EMBED2000+ Spectrometer includes the linear CCD-array optical bench, plus all the circuits necessary to operate the array and convert to a digital signal.

More information

XUV pulse FLASH

XUV pulse FLASH W (GW) XUV pulse duration @ FLASH 50 85µm with bandpass filter 55 60 Kinetic Energy [ev] 65 70 75 80 85 90 95 100 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 Delay [ps] 80 60 40 20 0 0 50 100 150 200 250 300 t (fs)

More information

Pinpoint Quick Start Guide

Pinpoint Quick Start Guide Pinpoint Quick Start Guide Thermo Pinpoint, version 1.0 and later 1, targeted protein quantification software simplifies the creation of processing methods and helps you do the following: Select targeted

More information