SECTION 1 PT SERIES CONTROL TRANSFORMERS
|
|
- Thomasine Sims
- 6 years ago
- Views:
Transcription
1 PT SRIS ONTROL TRNSORMRS PT Series ontrol Transformer - pplications The Hammond PT series of machine tool transformers, now Marked, are specifi cally designed for high inrush applications requiring reliable output voltage stability. esigned to meet industrial applications where electromagnetic devices such as relays, solenoids, etc. are used, the Hammond PT series transformers maximize inrush capability and output voltage regulation when electromagnetic devices are initially energized. STNRS Hammond Industrial and Machine Tool ontrol and Instrument Transformers meet or exceeds the standards established by UL, S, IR, NSI, NM. Standard ile # V Size UL (NSI/UL 506) ll PT S (22-2 No. 66) LR3902 ll PT I 989 NM (ST-1) ll Molded PT s ll PT t HMMON, we rate the V capacity of our transformers at the output... where it counts. Other transformer manufacturers rate their capacity on the input side of the transformer, which can result in a 5% to 20% lower actual V at the output. 32
2 STION 91 PT SRIS ONTROL TRNSORMRS eatures enefits OR & OILS High quality, high permeability silicon steel laminations. ll-welded construction. omputer designed copper wound coils with optimum turns ratio. INSULTION Mylar, Nomex and other insulating materials are used for phase to phase and layer to layer insula tion. The PT series transformers have the following insulation systems: Up to 200 V ; class, 55 rise, 105 class. 250 to 1000 V ; class, 80 rise, 150 class V and up ; class, 115 rise, 180 class. VUUM IMPRGNTION ll Hammond ontrol Transformers are Vacuum Impregnated with VT (vinyl-toluene) Polyester Resin. Oven cured after vacuum impregnating. MOL ONSTRUTION ll PT series transformers, up to 1000 V, are molded in a UL 94 fl ame retardant polyester compound. These units have a thermal plastic, injection molded cover with distinctive cooling fi ns. TRMINL LOKS abricated from molded high-impact resin, fi nished in black. ombination Phillips (#2) and Robertson (# 2) Red terminal screws with #9 head, 8-32 UN threads. Terminals are tinned brass and chrome plated, and all connections are soldered. Terminals are torque tested with automatic drivers. NMPLT lack letters on white background including terminal markings, schematic and mark.. Polyester, nonconductive material. MOUNTING PLT Offers an unique Universal Plate made of heavy steel, welded to the core. INGR S TRMINL OVRS inger safe terminal covers for both fused and unfused terminals, in a clear, see through fi nish, are available for all molded PT series units. STNR SONRY US LIPS ach PT series transformer, that has a single secondary, comes with a factory installed secondary fuse kit (fuses not included). OR & OILS Provides optimum performance and reliability. Rugged one-piece assembly with low noise. nhanced voltage regulation with excellent thermal characteristics. INSULTION Provides the best insulated control transformer in the industry. Insulation materials are of the highest rating available for the temperature class. ssures long life and reliable performance. VUUM IMPRGNTION Impregnating the entire unit provides a strong mechanical bond and offers protection against environmental conditions. Seals the surface and eliminates moisture. MOL ONSTRUTION ompletes the protection process by sealing the core and coils against moisture, dirt and other airborne contaminants. Strong and durable, yet still dissipates heat quickly and effi ciently. TRMINL LOKS asy access to terminals while separation barriers prevent unintentional contact. Versatile screw head with optimum torque and retention ability. ssures integrity and strength of connections and terminals Withstands any manual installation method. NMPLT ase of readability results in easier installation. Safe for other conductors, even in close proximity. MOUNTING PLT Provides direct interchangeability with many other popular control transformers. INGR S TRMINL OVRS This ensures your protection against electric shock or accidental contact of any kind, and complies with I and requirements. STNR SONRY US LIPS ccommodates 13/32 X 1 1/2 Midget use. 33
3 PT SRIS ONTROL TRNSORMRS or detailed mounting dimensions by V size, please refer to diagrams on Page 46. IGUR IGUR Group 240/480, 230/460, 220/ , 115, 110 H3 H V 11 X H4 X1 Supply Lines Install Jumpers 240, H4 -H3, H2-H4 230, H4 -H3, H2-H4 220, H4 -H3, H2-H4 480, H4 H3-H2 460, H4 H3-H2 440, H4 H3-H2 120, X 115, X 110, X 25 PT25MQMJ X PT50MQMJ X PT75MQMJ X PT100MQMJ X PT150MQMJ / X PT200MQMJ / X PT250MQMJ / X PT300MQMJ / x PT350MQMJ / X PT500MQMJ / X PT750MQMJ / X PT1000MQMJ / X PT1500MQMJ / x PT2000MQMJ / x PT3000MQMJ / x PT5000MQMJ / x Height dimension () does not include fuse clip (applicable up to 100 jumpers are included. fuse clips for 13/32 X 1 1/2 fuse included up to 100. Open style units (150 to 500) do not carry the mark. The output amps listed above are based on a 115V secondary. 34
4 STION 91 PT SRIS ONTROL TRNSORMRS Group 575, 460, , 95 X3 575V 48 H3 23 H2 95V 115V H4 X1 Supply Lines Install Jumpers 575, H4 460, H3 230, H2 115 X1, X3 95 X1, 25 PT25MMH X PT50MMH X PT75MMH X PT100MMH X PT150MMH / X PT200MMH / X PT250MMH / X PT300MMH / x PT350MMH / X PT500MMH / X PT750MMH / X PT1000MMH / X PT1500MMH / x PT2000MMH / x PT3000MMH / x PT5000MMH / x jumpers and fuse clips are not applicable. jumpers are included. Open style units (150 to 500) do not carry the mark. The output amps listed above are based on a 115V secondary. Group 240/ H3 24V H2 X H4 X1 Supply Lines Install Jumpers 480, H4 H2-H3 240, H4 -H3, H2-H4 24, X 25 PT25QG X PT50QG X PT75QG X PT100QG X PT150QG / X PT200QG / X PT250QG / X PT300QG / x PT350QG / X PT500QG / X PT750QG / X jumpers and fuse clips for 13/32 X 1 1/2 fuse are included. 35
5 PT SRIS ONTROL TRNSORMRS or detailed mounting dimensions by V size, please refer to diagrams on Page 46. IGUR Group 120/ H3 H2 24V X H4 X1 Supply Lines Install Jumpers 120, H4 -H3, H2-H4 240, H4 H2-H3 24, X 25 PT25PG X PT50PG X PT75PG X PT100PG X PT150PG / X PT200PG / X PT250PG / X PT300PG / x PT350PG / X PT500PG / X PT750PG / X jumpers and fuse clips for 13/32 X 1 1/2 fuse are included. 36
6 STION 91 PT SRIS ONTROL TRNSORMRS Group X H2 X1 Supply Lines Install Jumpers 480, H2 240, X 25 PT25M X PT50M X PT75M X PT100M X PT150M / X PT200M / X PT250M / X PT350M / X PT500M / X PT750M / X PT1000M / X fuse clips for 13/32 X 1 1/2 fuse are included. jumpers not applicable. Group 460, 230, H3 208V H2 115V X H4 X1 Supply Lines Install Jumpers 460, H4 230, H3 208, H2 115, X 25 PT25MLI X PT50MLI X PT75MLI X PT100MLI X PT150MLI / X PT200MLI / X PT250MLI / X PT300MLI / x PT350MLI / X PT500MLI / X PT750MLI / X PT1000MLI / X fuse clips for 13/32 X 1 1/2 fuse are included. jumpers not applicable. 37
7 PT SRIS ONTROL TRNSORMRS or detailed mounting dimensions by V size, please refer to diagrams on Page 46. IGUR Group GG 600, 575, , 115, V V 11 X H2 X1 Supply Lines Install Jumpers 600, H2 575, H2 550, H2 120, X 115, X 110, X 25 PT25MMJ X PT50MMJ X PT75MMJ X PT100MMJ X PT150MMJ / X PT200MMJ / X PT250MMJ / X PT300MMJ / x PT350MMJ / X PT500MMJ / X PT750MMJ / X PT1000MMJ / X fuse clips for 13/32 X 1 1/2 fuse are included. jumpers not applicable. The output amps listed above are based on a 115V secondary. 38
8 STION 91 PT SRIS ONTROL TRNSORMRS Group HH 415, / V H2 H3 X4 X3 X1 Supply Lines Install Jumpers 415, H3 380, H2 110 X1, X4 X1-X3, -X4 220 X1, X4 -X3 25 PT25MMX 0.23/ X PT50MMX 0.45/ X PT75MMX 0.68/ X PT100MMX 0.91/ X PT150MMX 1.36/ / X PT200MMX 1.82/ / X PT250MMX 2.27/ / X PT350MMX 3.18/ / X PT500MMX 4.55/ / X PT750MMX 6.82/ / X PT1000MMX 9.09/ / X jumpers are included. jumpers and secondary fuse clips are not applicable. Group II 380, 277, V H3 208V H2 12 X H4 X1 Supply Lines Install Jumpers 380, H4 277, H3 208, H2 120, X 25 PT25MGJ X PT50MGJ X PT75MGJ X PT100MGJ X PT150MGJ / X PT200MGJ / X PT250MGJ / X PT300MGJ / x PT350MGJ / X PT500MGJ / X PT750MGJ / X PT1000MGJ / X fuse clips for 13/32 X 1 1/2 fuse are included. jumpers not applicable. 39
9 PT SRIS ONTROL TRNSORMRS or detailed mounting dimensions by V size, please refer to diagrams on Page 46. IGUR IGUR Group JJ (Universal, Open Style Transformer) 600, 480, 416, , 120, 99 H2 H3 H4 H V 416V 48 X4 X3 X1 60 Supply Lines Install Jumpers 600, H5 480, H4 416, H3 240, H2 130 X1, X4 120 X1, X3 99 X1, 50 PT50MRM X PT75MRM X PT100MRM X PT150MRM / X PT200MRM / X PT250MRM / X PT350MRM / X PT500MRM / X and jumpers, and fuse clips are not applicable. Group JJ open style units from (5 to 50) do not carry the mark. The output amps listed above are based on a 12 secondary. Group KK (Universal, Open Style Transformer) 480, 380, 277, 240, H2 H3 H4 H5 H6 50 PT50MSG X PT75MSG X PT100MSG X PT150MSG / X PT200MSG / X PT250MSG / X PT350MSG / X PT500MSG / X fuse clips for 13/32 X 1 1/2 fuse are included. jumpers not applicable. Group KK open style units (5 to 50) do not carry the mark. 208V 24 24V 277V X X1 Supply Lines Install Jumpers 480, H6 380, H5 277, H4 240, H3 208, H2 24, X 40
10 STION 91 PT SRIS ONTROL TRNSORMRS or detailed mounting dimensions by V size, please refer to diagrams on Page 46. Group LL 240/480 12/24 IGUR H3 H2 H4 X4 X3 X1 Supply Lines Install Jumpers 480, H4 H2-H3 240,H4 -H3, H2-H4 12 X1, X4 X1-X3, -X4 24 X1, X4 -X3 25 PT25QR 2.08/ X PT50QR 4.17/ X PT75QR 6.25/ X PT100QR 8.33/ X PT150QR 12.5/ / X PT200QR 16.7/ / X PT250QR 20.8/ / X and jumpers are included. fuse clips are not applicable. Group MM 415, 400, /220 H2 H3 H X4 X3 X1 415V Supply Lines Install Jumpers 415V, H4 40, H3 38, H2 11 X1, X4 X1-X3, -X4 22 X1, X4 -X3 25 PT25MMX 1.04/ x PT50MMX 2.08/ x PT75MMX 3.13/ x PT100MMX 4.17/ x PT150MMX 6.25/ / x PT200MMX 8.33/ / x PT250MMX 10.42/ / x PT350MMX 14.58/ / x PT500MMX 20.83/ / x PT750MMX 31.25/ / x PT1000MMX 41.67/ / x jumpers and fuse clips are not applicable. jumpers are included. ll dimensions are inches unless otherwise specifi ed. *Hammond does not offer uropean style metric fuse clips. 41
11 PT SRIS ONTROL TRNSORMRS or detailed mounting dimensions by V size, please refer to diagrams on Page 46. IGUR Group NN 460, 230, 208, , 115 H2 H3 H4 115V V 24V X3 X X1 Supply Lines Install Jumpers 46, H4 23, H3 208V, H2 20, H2 115 X1, X3 24 X1, 25 PT25MHM 1.04/ x PT50MHM 2.08/ x PT75MHM 3.13/ x PT100MHM 4.17/ x PT150MHM 6.25/ / x PT200MHM 8.33/ / x PT250MHM 10.42/ / x PT350MHM 14.58/ / x PT500MHM 20.83/ / x fuse clips for 13/32 x 1 1/2 fuse included. jumpers not applicable. ll dimensions are inches unless otherwise specifi ed. *Hammond does not offer uropean style metric fuse clips. 42
12 STION 91 PT SRIS ONTROL TRNSORMRS Group OO 380, 277, , 120 fuse clips for 13/32 x 1 1/2 fuse included. jumpers not applicable. H2 H3 H V 24V 277V 38 X3 X X1 Supply Lines Install Jumpers 38, H4 277V, H3 208V, H2 12 X1, X3 24V X1, 25 PT25MGM 1.04/ x PT50MGM 2.08/ x PT75MGM 3.13/ x PT100MGM 4.17/ x PT150MGM 6.25/ / x PT200MGM 8.33/ / x PT250MGM 10.42/ / x PT350MGM 14.58/ / x PT500MGM 20.83/ / x ll dimensions are inches unless otherwise specifi ed. *Hammond does not offer uropean style metric fuse clips. Group PP 415, 400, , 120 H2 H3 H V V X3 X X1 Supply Lines Install Jumpers 415V, H4 40, H3 24, H2 12 X1, X3 24 X1, 25 PT25MM 1.04/ x PT50MM 2.08/ x PT75MM 3.13/ x PT100MM 4.17/ x PT150MM 6.25/ / x PT200MM 8.33/ / x PT250MM 10.42/ / x PT350MM 14.58/ / x PT500MM 20.83/ / x fuse clips for 13/32 x 1 1/2 fuse included. jumpers not applicable. ll dimensions are inches unless otherwise specifi ed. *Hammond does not offer uropean style metric fuse clips. 43
13 PT SRIS ONTROL TRNSORMRS or detailed mounting dimensions by V size, please refer to diagrams on Page 46. IGUR Group QQ 480, 415, , 120 H2 H3 H V V X3 X X1 Supply Lines Install Jumpers 40, H4 415V, H3 48, H2 12 X1, X3 24 X1, 25 PT25MM 1.04/ x PT50MM 2.08/ x PT75MM 3.13/ x PT100MM 4.17/ x PT150MM 6.25/ / x PT200MM 8.33/ / x PT250MM 10.42/ / x PT350MM 14.58/ / x PT500MM 20.83/ / x fuse clips for 13/32 x 1 1/2 fuse included. jumpers not applicable. ll dimensions are inches unless otherwise specifi ed. *Hammond does not offer uropean style metric fuse clips. 44
14 STION 91 PT SRIS ONTROL TRNSORMRS Group RR 240/ /240 H3 H2 H4 X4 X3 X1 Supply Lines Install Jumpers 240, H4 -H3, H2-H4 480, H4 H2-H3 120 X1, X4 X1-X3, -X4 240 X1, X4 -X3 25 PT25QP 0.21/ x PT50QP 0.42/ x PT75QP 0.63/ x PT100QP 0.83/ X PT150QP 1.25/ / x PT200QP 1.67/ / x PT250QP 2.08/ / x PT300QP 2.50/ / x PT350QP 2.92/ / x PT500QP 4.17/ / x PT750QP 6.25/ / x PT1000QP 8.33/ / x fuse clips for 13/32 X 1 1/2 fuse are included. jumpers not applicable. Group SS 120/ /240 H3 H2 H4 X4 X3 X1 Supply Lines Install Jumpers 120, H4 -H3, H2-H4 240, H4 H2-H3 120 X1, X4 X1-X3, -X4 240 X1, X4 -X3 25 PT25PP 0.21/ x PT50PP 0.42/ x PT75PP 0.63/ x PT100PP 0.83/ X PT150PP 1.25/ / x PT200PP 1.67/ / x PT250PP 2.08/ / x PT300PP 2.50/ / x PT350PP 2.92/ / x PT500PP 4.17/ / x PT750PP 6.25/ / x PT1000PP 8.33/ / x fuse clips for 13/32 X 1 1/2 fuse are included. jumpers not applicable. 45
15 PT SRIS ONTROL TRNSORMRS etailed imensions V V X 0.44 Slots (4) 0.22 X 0.75 Slots (4) V, 100 V 150 V, 200 V, 250 V L X 0.50 Slots (4) 0.22 X 0.75 Slots (8) V, 500 V 750 V, 1000 V L 0.22 X 0.75 Slots (8) G X H Slots (8) plates for units larger than 100 are not illustrated. Please consult customer service for any information you require. 46
16 STION 91 PT SRIS ONTROL TRNSORMRS 47
AE/CE Series Industrial Control Transformers
5 AE/E Series Industrial ontrol Transformers SETION TA AE/E SERIES SERIES OPEN ORE INDUSTRIAL & OIL INDUSTRIAL ONTROL ONTROL TRANSFORMERS The Acme Electric AE and E Series Industrial ontrol Transformers
More informationIndustrial Control. 50 to 5,000 VA. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.
Industrial Control 6 50 to 5,000 VA Applications n For commercial and industrial control applications including; control panels, conveyor systems, machine tool equipment, pump systems, and commercial air
More informationAE/CE Series Industrial Control Transformers
AE/E SERIES INDUSTRIAL ONTROL TRANSFORMERS AE/E Series Industrial ontrol Transformers The Acme Electric AE and E Series Industrial ontrol Transformers are designed specifically for machine tool control
More informationIndustrial Control. 50 to 5,000 VA. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.
Industrial Control 6 50 to 5,000 VA Applications n For commercial and industrial control applications including; control panels, conveyor systems, machine tool equipment, pump systems, and commercial air
More informationMini-Universal MATE-N-LOK 2 Connectors
MP Mini-Universal MTE-N-LOK 2 Product Facts One molded piece, secondary locking plug and cap housing assemblies Three-point stabilization to provide better terminal position Fully polarized to provide
More informationMini-Universal MATE-N-LOK Connectors
MP Mini-Universal MTE-N-LOK Product Facts Compact, durable housings Pins and sockets can be accommodated in the same housings Contacts fully protected in the housings. Both pins and sockets can be used
More informationElectrical Components Catalog Universal MATE-N-LOK Connector System
Introduction Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification Contacts completely enclosed in housings Positive locking housings Insulation
More informationDistributed by: www.jameco.com -800-8-44 The content and copyrights of the attached material are the property of its owner. Pin and Socket Mini-Universal MTE-N-LOK Product Facts Compact, durable housings
More informationMini-Universal MATE-N-LOK Connectors
MP Mini-Universal MTE-N-LOK Product Facts Compact, durable housings Pins and sockets can be accommodated in the same housings Contacts fully protected in the housings. Both pins and sockets can be used
More informationPower Electronics. Semiconductor relay / - contactor
Power Electronics Semiconductor relay / - contactor PH 9260 POWERSWITCH 0247349 Semiconductor relay PH 9260.91 Semiconductor contactor PH 9260.91/000/01 AC semiconductor relay / -contactor According to
More information[.050 (1.27mm) Density. D-Microminiature]
Commercial [.050 (1.27mm) Density Solder Introduction Cup/Wire D-Microminiature] Cinch Commercial Products, consisting of Jones Plugs and Sockets, Barrier Blocks, Edge Cards, Two-Piece Commercial Dins,
More informationFT & RT Test Switches
GE Grid Solutions FT & RT Test Switches Key Benefits The FT Switches and FT Test Plugs have all the features necessary for applications involving the measurement of individual currents and voltages to
More informationDura-ConTM Hermetic Connectors
Dura-ConTM Hermetic Connectors Standard Connectors With High Performance Hermetic Seals Catalog cinch.com Cinch Dura-Con Hermetic Connectors offers a high performance hermetic seal designed into our standard
More informationUltra Slim Relays 24
Ultra Slim Relays 24 Technical Data... 1 Specifications.2 Model Number Structure - Relays...3 Model Number Selection...4 Accessories...5 Safety Precautions...6 Ultra Slim Relays WERNER`s embody the latest
More informationRigid/Bus Bars. Standard Copper Rigid / Bus. PC Board Stiffeners and Current Carrying Busses. Table of Contents. Benefits
Rigid/Bus Bars Circuit Components Inc. PC Board Stiffeners and Current Carrying Busses Table of Contents Standard Copper Rigid Bus Benefits...1 Part Specifications..2 Part Drawings.3 Snap-In Board Stiffener
More informationE-Series General Specifications
-Series General Specifications Ideally suited for higher amperage applications. Available with front and back mounting, screw terminals, stud terminals and heavy duty box wire connectors for solid wire
More informationMini-Universal MATE-N-LOK Connectors
MP Mini-Universal MTE-N-LOK Product Facts Compact, durable housings Pins and sockets can be accommodated in the same housings Contacts fully protected in the housings. Both pins and sockets can be used
More informationENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS
Hammond Power Solutions Inc. Page 1 of 1 ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS HPS Titan has been designed to operate in harsh environments/hazardous locations where dangerous gases, liquids,
More informationENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS
ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS 2 ENERGY /// TE'S CROMPTON INSTRUMENTS 3 Table of contents I. Tape Wound Measuring and Protection Current MR Series Measuring
More informationPCB Hardware. Contents. SMT Test Points SMT Cable Clips SMT Jumper Links PCB Jumper Links PCB Terminals, Turret Lugs Spacers / Pillars / Standoffs
PC Hardware Contents SMT Test Points SMT Cable Clips SMT Jumper Links PC Jumper Links PC Terminals, Turret Lugs Spacers / Pillars / Standoffs SMT Hardware Test Points Ideal for use with standard probes,
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationBulletin 1494H Heavy Duty Safety Switches
ulletin H Heavy uty Safety isconnect Switches Product Overview/Product Selection Fusible and Non-Fusible Type ulletin H Heavy uty Safety Switches switch ratings Type, R, or enclosures V: -phase, -phase,
More informationPC Card Single Slot SMT Connectors for the AV Market (that Support 5 V Cards)
PC Card Single Slot SMT Connectors for the V Market (that Support 5 V Cards) IC15 Series Reliable card ejection 2-point card ejection Card ejection distance 6mm min Equipment outline Stroke: 11.7mm Ejection
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor
More informationPCB Hardware. Contents
PC Hardware Contents SMT Test Points SMT Cable Clips Coin Cell Holders SMT Jumper Links PC Jumper Links PC Terminals, Turret Lugs Spacers / Pillars / Standoffs SMT Hardware Test Points Ideal for use with
More informationMagnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158
Magnetic Circuit Protectors 53 Multi-Pole Circuit Protectors 54 APL/UPL, 205/295 Barriers 55 Configurations 56 Operating Characteristics 58 Delay Curves 59 Specifications 64 APL/UPL Decision Tables 70
More informationCommercial MATE-N-LOK Connectors
MP Commercial MTE-N-LOK Connectors Product Facts Fully polarized nylon housings Easy cavity identification Locking devices are integral part of design. Connector halves will hold together under severe
More informationAudio Patching Systems ProPatch Programmable (PPP) Series
The ProPatch Programmable modular system offers unprecedented reliability and flexibility in a convenient, space-saving size and lightweight package. Specifically engineered for everyday use in demanding
More information(MR) Miniature Rectangular Connectors (Continued)
Product Facts Housings positively lock to help prevent accidental disengagement Either cap or plug housing can be mounted in same rectangular panel cutout without additional hardware UL94V-0 housings Plug
More informationAmphenol. Printed Circuit Board Technology NAFI + UHD CONNECTORS STANDARD. RELIABLE. PROVEN.
Amphenol Printed Circuit Board Technology NAFI + UHD CONNECTORS STANDARD. RELIABLE. PROVEN. UHD FEATURES & BENEFITS 0.100 x 0.050 staggered grid - High density optimizes trace routing through the backplane
More informationTime Delay Values (E-Series)
Time Delay Values (ESeries) AC Instantaneous 00 0 INSTANTANEOUS CURVE NO. 20 00 0 DC D.C. INSTANTANEOUS CURVE NO. 0 0. 0..0.0.00 200 300 400 500 700 800 900 0 200.00 200 300 400 500 700 800 900 0 200 Short
More informationSeries PC 3.5 precision subminiature connectors
Series PC 3.5 precision subminiature connectors Description Content HUBER+SUHNER PC 3.5 connectors are precision connectors for use in microwave applications up to 26.5 GHz. They are especially suitable
More informationPower Connectors & Interconnection Systems
Product Facts Available in latch versions for VRMs up to 3 oz. Available with metal clip for VRMs over 3 oz. VRM connectors to support a wide variety of power supply standards Solder tail, press-fit and
More informationand see how good you look! Dress it with a SIMCO housing 2004 PRODUCT SELECTION GUIDE FOR PLASTIC ENCLOSURES Handheld Cases Pocket Size Enclosures
Pocket Size Enclosures Handheld Cases Desktop Housings Utility Boxes Dress it with a SIMCO housing and see how good you look! 2004 PRODUCT SELECTION GUIDE FOR PLASTIC ENCLOSURES PRECISION ENCLOSURES TO
More informationINCHES (MILLIMETERS) CUSTOMER DRAWINGS AVAILABLE ON REQUEST
TNC Connectors Flexible Cable... 3 In-Series Adapters... 4 Specifications... 2 RF Adapter Kit Adapters... 6 N Connectors Panel Mount and In-Series Adapters... 10 Flexible Cable... 8 Specifications... 7
More informationAPL/UPL, 205/295 Series Magnetic Circuit Protectors
APL/UPL, 205/295 APL/UPL, 205/295 Series Magnetic Circuit Protectors Introduction 68 Single & Multi-Pole 69 Barriers 7 Configurations 72 Operating Characteristics 74 Delay Curves 75 Specifications 80 Decision
More informationHD10 Series. HD10 Series Overview HD P * XXXX. Part Numbering System. Dimensions. Cavity. Overall Length. Overall Length.
H10 Series H10 Series Overview The H10 is an environmentally sealed, thermoplastic cylindrical connector series and offers arrangements from 3 to 9 cavities. ll H10 connectors are available either in-line
More informationContact form. Operating Force. SPDT 100g Unsealed Solder / 187 Quick Connect. SPDT 200g Unsealed Solder / 187 Quick Connect
V Miniature Snap Action Switch Industry standard design with 10/15 Amp ratings Long mechanical life of 50,000,000 operations minimum Available in either thermoplastic or thermosetting resin Can be used
More information7.92 mm Contact Pitch, High-Current Connectors for Internal Power Supplies (UL, C-UL and TÜV Listed)
NEW 7.9 mm Contact Pitch, High-Current Connectors for Internal Power Supplies (UL, C-UL and TÜV Listed) DF Series Complete Locking Function Completely enclosed locking system Protection from shorts circuits
More informationFlexible connectors made out of copper- and aluminium foils
Fleible connectors made out of copper- and aluminium foils We offer a wide range of standardized laminated connectors as well as multifarious designs according to your drawings or wishes. All articles
More informationIn-Series and Between-Series Adapters SMA
Adapters SMA In-Series and Between-Series Adapters SMA If your choice of SMA Adapter is not shown in this section, please refer to the Table below to determine other possible locations. Should you not
More informationStandard Size Rotaries Series HS TS PS
Standard Size Rotaries Series HS TS PS GENERAL SPECIFICATIONS Electrical Capacity Resistive Load: Other Ratings Contact Resistance: Insulation Resistance: Dielectric Strength: Mechanical Life: Electrical
More informationM-Line Series MN Multi-Pin Plugs and Receptacles Vac, Vdc
Applications Designed for the roughest industrial applications, providing reliable, rugged service for power, control and instrumentation. For use in the roughest industrial applications, ranging from:
More informationALLEN BRADLEY RELAY Bulletin 700-HF
ALLEN BRADLEY RELAY Bulletin 700-HF Contact Rating DPDT, 3PDT, 4PDT Plug-in Quick Connect Solder Terminals Options: LED, Push-to-Test Operator DEMENSIONS: Bulletin 700-HF Relay (DPDT) Bulletin 700-HF (3PDT)
More informationCord- Mounted Female. Mounted Male. Strain relief clamp # needs to be ordered separately w/cord-mounted connections.
-Pin Amp Plastic 0883 Kit (consists of) 080 Receptacle 03 Pins (Qty ) 088 Kit (consists of) 080 Connector 03 Sockets (Qty ) Note: Strain relief clamp 03 needs to be ordered separately with cord-mounted
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationCROWN CLIP Series Sockets
OWN LIP Series Sockets Product Facts ompact design High performance OWN BND contacts urrents to 350 mps 1 Mates with solid or laminated blades Supports true hot-plug (current interruption)2 Float-mount
More informationEXTreme Guardian Power Connector System
Exceed high-current and reliability requirements in topend server and high-power applications with Molex s compact,, providing EMI/RFI shielding, overmolding and discretewire options for design flexibility
More informationApplications & Features, Type SSMP When using blind mate connectors in an application, careful consideration has to be given to choosing the right con
SSMP Push-On Connectors & Adapters THE SSMP (Sub-Sub-Miniature-Push-On) is a 1.7 mm connector, using solid dielectric interface. The connector is 70% of the size of the SMP and therefore allows even higher
More informationAmphenol. Printed Circuit Board Technology NAFI + UHD CONNECTORS STANDARD. RELIABLE. PROVEN.
Amphenol Printed Circuit Board Technology NAFI + UHD CONNECTORS STANDARD. RELIABLE. PROVEN. FEATURES & BENEFITS Available in 2 through 4 rows - Offers maximum design flexibility Tested and qualified to
More informationIntroduction to High Current Card Edge Connectors
Introduction to High Current Card Edge Connectors Product Facts Contacts on.100 [2.54] Centerlines Selective gold plating of contacts for high performance at low cost Flow solder applications Glass-filled
More informationOverall Dimensions AE2M-1000 MADJ MW(X)CBLKMP 1000-MPBM. For Reference Only
AE2M-1000 MADJ MW(X)CBLKMP (Fixture Series) Overall Dimensions Optic Assembly 1000-MPBM (Remote Ballast Series) Weight Remote Ballast 65 lbs (29.48 kgs) For Reference Only The Arena Eclipse blackout luminaire
More informationAZ420 MINIATURE GENERAL PURPOSE RELAY
MINIATURE GENERAL PURPOSE RELAY FEATURES Rugged construction for high reliability Life expectancy greater than 100 million operations DC coils to 11 V Power consumption as low as 2 mw per pole available
More informationK1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm
Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationInstallation Job Aid for VSP 4850GTS
Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe
More informationIntroduction. The information pages provide standard data common to all D-subminiature connectors. These include:
Connectors Information Introduction The D-subminiature is one of the most popular styles of connectors in the I/O category. It is used in computer, telecom, datacom, medical, and test instrumentation applications
More informationSafety switches with separate actuator
A Safety switches with separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS CONTACT BLOCKS 9 snap action overlapped FD FP FL FC 21 22 33 3 3NC 2NO+1NC 1NO+ CONDUIT
More informationThe Custom Interconnect Leader
7-16 Series.354.276.843.811 ELECTRICAL Nominal Impedance: Frequency Range: Voltage Rating: Dielectric Withstanding Voltage: Insulation Resistance: VSWR: Intermodulation: 50 ohms DC to 7 GHz 2,700 volts
More informationContact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect
VX Miniature Snap Action Switch Compact snap action switch with low force operation Internal mechanism assures outstanding contact reliability Models available for micro load up through 5 Amps ROHS Compliant
More informationInstallation Job Aid for VSP 4450GTX-HT- PWR+
Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs
More informationSMA - 50 Ohm Connectors
Alphabetical Index 142-0701-201 4 142-0701-206 4 142-0701-231 4 142-0701-235* 4 142-0701-236 4 142-0701-301 5 142-0701-306 5 142-0701-335* 6 142-0701-421 5 142-0701-426 5 142-0701-491 5 142-0701-496 5
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationBOARD LEVEL POWER SEMICONDUCTOR HEAT SINKS
217 SERIES Surface Mount D 2 PAK,, SOT-223, SOL-2 Compatible with surface mount technology (SMT) automated production techniques for ease of assembly and a variety of soldering methods, these heat sinks
More informationPolyester enclosures
Polyester enclosures Features Polyester enclosures hemical-resistant Temperature-resistant Flame-retardant Use in Ex areas with a surface resistance < 10 9 Ω, black enclosure orrosion-proof Seawater-proof
More information78xxSR Series 3.3V/5V/12V Outputs High-Effi ciency Switching Regulators with LM78xx Pinouts
www.murata-ps.com FEATURES 3.3V/0.5A, 5V/0.5A or 12V/0.4A outputs; Pin and size-compatible with LM7805 & LM7812 regulators Up to 95% effi ciency no heat sinks or thermal derating required Two SIP-packages
More informationSPRING - LOADED CONNECTORS
SPRING - LOADED CONNECTORS SPRING LOADED CONNECTORS QUICK SELECTOR CHART SPRING-LOADED CONNECTORS AND PAD CONNECTORS GRID 1.25 mm 2.54 mm SINGLE ROW SINGLE ROW DOUBLE ROW SLC CONNECTORS SEE PAGE Straight
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60
DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery
More informationPART NUMBER BREAKDOWN CP A 46 1 W D B1 - VG0-8
SERIES 46 EMI/RFI Shrink Boot Adapter Environmental, Shielding Series 46 EMI/RFI Shrink Boot Adapters allow an outer cable shield to be terminated using either an AS85049/128 Termination Band or Constant
More informationElma Bustronic CompactPCI Reference Sheet
Elma Bustronic CompactPCI Reference Sheet Rev. 4 5.10.10 The cpci reference sheet provides relevant reference material for the CompactPCI product line. The information provided may change at anytime. Elma
More informationCOLONIAL BOLLARD LED SERIES
COLONIAL LED SERIES PROJECT NAME: FIXTURE TYPE: Durable, corrosion resistant, heavy cast low copper aluminum assembly (A356 alloy,
More informationPGA / BGA / PLCC SOCKETS
PGA / BGA / PLCC SOCKETS QUICK SELECTOR CHART PGA / BGA / PLCC PGA BGA PLCC GRID 2.54 mm INTERSTITIAL 1.27 mm 1.27 mm 1 mm SOCKETS Solder tail 156 161 165 SEE PAGE 173 Surface mount 156 161 165 166 169
More informationSafety switches with manual mechanical delay and separate actuator
D Safety switches with manual mechanical delay and separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF VF KEYF VF KEYF7 VF KEYF ACTUATORS MECHANICAL DELAY C L L0 Short knob 0 sec. Short knob sec.
More information2mm Pitch, Multi functional Connector System. (Floating [Board-to-Board], Swing-Lock [Wire-to-Board], Short Pin)
NEW 2mm Pitch, Multi functional Connector System. (Floating [Board-to-Board], Swing-Lock [Wire-to-Board], Short Pin) DF59 Series Floating Structure in Three xial Directions (Board-to-Board Structure) X
More informationSPRING - LOADED CONNECTORS
SPRING - LOADED CONNECTORS SPRING LOADED CONNECTORS Quick Selector Chart Spring-loaded connectors and Pad connectors TEL +1 32 21 0 00 2 mm 2.5 mm 3 35, 36 35, 36 Surface mount perpendicular with positioning
More informationModular FLATPAQ. provided, and Elcon will provide samples, typically within one week.
Modular FLATPAQ Modular FLATPAQ connectors provide custom solutions to hot pluggable AC and DC power needs in a board-to-board format. By using off-the-shelf modular components, power and signal modules,
More informationTempco Instruction Manual
Tempco Instruction Manual 1/16 DIN Solid State Temperature Controller Relay Output Solid State Output For Heating Model Numbers: TEC-901, TEC-902, TEC-905 Temperature controls in this series are designed
More informationGLASS TAKE-OUT HOLDERS AND INSERTS
GLSS TKE-OUT HOLERS N INSERTS Full line of holders and GLSSMTE inserts lanks POO hot glass handling materials have high strength, durability and excellent thermal properties that reduce mechanical damage.
More informationUniversal MATE-N-LOK Connectors
Product Facts Pins and sockets can be intermixed in the same housing Positive polarisation Rear cavity identification Contacts completely enclosed in housings Positive locking housings Insulation capability
More informationSMA Series. Specification. Description. Applications Civil & Military Telecommunication Instrumentation SMA SMA. Interface Mating Dimensions
Series Specification 50 ohm 0-18 GHZ connectors are adaptable to interconnection requirements of both systems and components. S-Conn offers a wide variety of cable connectors, receptacles, feed thrus,
More informationEN3 SERIES WEATHERTIGHT CONNECTORS NEW PRODUCT BULLETIN 602
FEATURES & BENEFITS Sealed to IP68 NEMA 250 (6P) Patented grommet & o-ring free design Available in ribbed or winged coupling ring Cable, panel & cable to cable options Gold plated contacts standard Solder,
More informationPower supplies CP-E, CP-S and CP-C range NEW! CP-E Range
Power supplies CP-E, CP-S and CP-C range CP-E Range The new CP-E range power supplies M odern switch mode AC to DC power supplies are a vital component in most information gathering systems, energy management,
More informationSECTION DISTRIBUTION SWITCHBOARDS
PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 26 24 11 This section specifies the furnishing, installation, and connection of the distribution switchboards. 1.2 RELATED WORK: A. Section 13 05 41, SEISMIC RESTRAINT
More informationRM84 miniature relays
RM84 miniature relays RM84 Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load (capacity) AC AC1 AC15 DC1 DC13 Motor load acc. to
More informationRTE02 and RTE03 Miniature Rotary Switches
RTE02 and RTE03 Miniature Rotary Switches RTE02 and RTE03 are two types of a subminiature rotary changeover switch to be mounted on PC boards. PC pins are in a 2.54 mm (0.100) grid. RTE02 with 2 positions
More informationCompact Medium SOLARLOK Junction Box. Application Specification
Application Specification 114-106003 10OCT. 2010 Rev. A2 Compact Medium SOLARLOK Junction Box Application Specification CONTENT 1. Introduction...2 2. Supporting Documents...2 2.1 Drawings...3 2.2 Product
More informationInductive Proximity Sensor
Inductive Proximity Sensor Miniature, Slim-styled Proximity Sensor Space-saving Sensor ideal for timing cam and dog detection. Four mounting holes provided: two each mounting from side or rear of the housing.
More informationModel 720 Electromechanical Hour Meter
Model 720 Electromechanical Hour Meter A 5 figure (reset) or 6 figure (non-reset), AC hour meter encased in a rugged steel housing and designed to mil-spec environmental requirements. The non-reset models
More informationDynamic Series Connectors
D-5000 Series Series profile The Dynamic 5000 series was developed for up to 5 amperes in response to the demand for improved reliability and productivity for the main power lines in equipment. They can
More informationTeSys contactors From 115 to 2750 A
Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,
More informationUTME 6. Extract from the online catalog. Order No.:
Extract from the online catalog UTME 6 Order No.: 3047400 Test disconnect terminal block, Connection method: Screw connection, Cross section: 0.2 mm² - 10 mm², AWG: 24-8, Width: 8.2 mm, Color: gray, Mounting
More informationPRODUCT SPECIFICATION. PC Board Relays. Series.
PRODUCT SPECIFICATION PC Board Relays 26 Series www.wernerelektrik.com Technical Data... Specifications...2 Model Number Structure - Relays...3 Model Number Selection...4 Dimensions... 5-6 Accessories...7
More informationMCX Connectors. Alphabetical Index. Johnson Components P.O. Box 1732 Waseca, MN Fax:
MCX Connectors Alphabetical Index 133-3701-201 3 133-3701-206 3 133-3701-211 3 133-3701-216 3 133-3701-221 3 133-3701-226 3 133-3701-231 4 133-3701-236 4 133-3701-301 5 133-3701-306 5 133-3701-311 5 133-3701-316
More informationDistinctive Characteristics
Distinctive Characteristics Top or side actuation permits flexible board design. Compact dimensions and low profile allow high density mounting and close stacking of PC boards. Crisp actuation positively
More informationHigh Density Connectors Multipin and MS Multipin MS High Current and High Voltage
Multipin is the description for electrical feedthroughs which have two or more conductor paths, and include connectors for one or both sides. This series is typically used for transmission of low power
More informationType NT and Type ZWM Terminal Blocks
Type NT and Type ZWM Terminal Blocks Unit-pole construction Sliding link to permit testing without disturbing wiring High barriers that prevent shorting between poles Class 1E qualified per IEEE RECOGNIZED
More informationK1D004ACH cam switch - 4-pole A - for Ø 22 mm
Characteristics cam switch - 4-pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing mode Cam
More informationIELR Rail-Mount Series Magnetic Circuit Protectors
IELR Rail-Mount IELR Rail-Mount Series Magnetic Circuit Protectors Introduction 92 Single Pole 93 Specifications 94 Operating Characteristics 95 Delay Curves 96 Approvals & Decision Tables 200 IELR Series
More informationZ-15GW2277 Z-15GW2277-B
Basic Switch GENERAL PURPOSE General Purpose Basic Switch High precision basic switch in a variety of styles Wide margins of operating conditions increase the operating speed range Available in general
More informationMTA-156 IDC Quad Connectors
MT-156 IDC Quad Connectors MT-156 Product Facts Provides four points of contact Greater current carrying capability than Standard MT-156 Connectors Connector styles include both closed end and feedthru
More informationTABLE I RANGE, POWER, OUTPUT (CONDUCTIVITY MEASUREMENTS)
Issue 11 Page 1 of 5 Model Selection Guide Instructions Consult Steps to Selecting Appropriate Conductivity Instrumentation and Cells before making selections below. Select the desired key number. The
More information