Intuitive and Touch Based Interface for ECG Acquisition Using Mobile Phones

Size: px
Start display at page:

Download "Intuitive and Touch Based Interface for ECG Acquisition Using Mobile Phones"

Transcription

1 Intuitive and Touch Based Interface for ECG Acquisition Using Mobile Phones Jürgen Morak, Hannes Kumpusch, Dieter Hayn Günter Schreier, AIT Austrian Institute of Technology GmbH Information Management & ehealth Graz - Hall in Tirol - Wien juergen.morak.fl@ait.ac.at

2 Introduction Touch based data acquisition Advantages of NFC based telemonitoring NFC based Bluetooth pairing Prototype for touch based ECG acquisition Results Conclusion Outlook 2

3 Patient terminal based on mobile phones and Near Field Communication (NFC) technology Nokia 6131 NFC or Nokia 6212 classic (commercially available mobile phones) Short range (5 cm) wireless communication technology Bring-in-Touch - paradigm Handled by J2ME software application reading contactless chip cards for authentication and identification exchange dynamic content with active NFC-module (i.e. read values from meter) touching RFID tags as user interface 3

4 Solution for intuitive data acquisition Touch ID card for identification launches application authenticates patient Touch meter reads recent measured value automatically Touch tag board with icons to confirm intake of up to 4 meds answer via YES, MORE, LESS, NO touch smiley to answer about well being 4

5 Advantages of using NFC Intuitive handling easy-to-use and easy-to-learn single page figure-based user manual Different kinds of data user IDs (multi-user) measurement values from meters further information Minimal effort on device management and maintenance inbuilt device management due to RFID no need for pairing -> uncomplicated device replacement 5

6 but lacks in terms of handling lots of data Disadvantages: Short operating range (5 cm) Low data rate ( kbit/s) Inapplicable for applications like Real time streaming of sensor data Download biosignals like 24h ECG Upload of device configuration / firmware update 6

7 Bluetooth may help, but Lots of usability issues Pairing process Search Select Enter pin code Device replacement need re-pairing Bluetooth has all time be switched on to enable an automatic workflow massive power consumption 7

8 Combination of both technologies Usage of NFC to Launch mobile sw. application Read Bluetooth pairing information MAC adress, service name, Pin code Start Bluetooth module (via field detector) Usage of Bluetooth to Establish a transparent peer 2 peer connection between mobile application and sensor device Control sensor device remotely via commands 8

9 NFC based Bluetooth pairing Bluetooth pairing information µc Acceptance Peer to peer of connection Bluetooth Inquiry connection based specific pairing information ADC Digital I/O 9

10 Combination of BP meter and ECG sensor 10

11 Combined acquisition of BP and ECG data Touching the meter with the phone launches the installed application (app) and activates the BT module of the sensor device App reads pairing info from RFID tag and establishes BT connection to sensor device without manual input App asks patient to put on the cuff and to touch the electrodes with the fingertips (acoustically) App sends command to sensor device that triggers BP measurement and ECG sampling (no human interaction at sensor device) Sensor device streams ECG data to mobile phone that displays the signal and a level of its quality until the BP measurement has finished 11

12 System overview Monitoring centre SYS DIA HRT Arzt Doctor 12

13 Results An easy-to-use wireless communication platform has been developed and implemented prototypically. This communication platform can be easily linked to a mobile phone by means of touching it and is able to transmit biosignal in real time. A mobile phone based patient terminal for the intuitive acquisition of ECG and blood pressure data was developed and integrated to an existing telemonitoring system. The complete system has been evaluated in terms of performance and usability and was rated to be ready for a clinical trial. 13

14 Conclusion By means of joining Bluetooth with NFC technology, an easy-to-use interface in between sensor device and mobile phones was realized. This concept could extend the existing monitoring solution and would allow for seamless acquisition of all kind of monitoring data, including biosignals, just by touching icons and sensor devices with a mobile phone. This touch based solution has the potential to significantly increase the usability of mobile phone and Bluetooth based telemonitoring applications for both the patient as well as the technical support. 14

15 Future prospects Starting a clinical trial with patients suffering from congestive heart failure Medical University of Graz 20 patients Blood pressure with ECG, body weight, medication intake, and well-being Adopting this approach to further biosignals Three dimension accelerometer sensor Curve of pulmonary function 15

16 Acknowledgement This project is partly funded by the Styrian government, department 3, science and research (Forschung Steiermark - Planung, Steuerung, Impulse - A3-22.E-4/ ). 16

DEVELOPMENT AND EVALUATION OF A MULTIMODAL WIRELESS DATA HUB FOR EHEALTH APPLICATIONS Akyildiz S 1, Morak J 1, Drobics M 2, Schreier G 1

DEVELOPMENT AND EVALUATION OF A MULTIMODAL WIRELESS DATA HUB FOR EHEALTH APPLICATIONS Akyildiz S 1, Morak J 1, Drobics M 2, Schreier G 1 DEVELOPMENT AND EVALUATION OF A MULTIMODAL WIRELESS DATA HUB FOR EHEALTH APPLICATIONS Akyildiz S 1, Morak J 1, Drobics M 2, Schreier G 1 Abstract To address the needs in the field of telemonitoring and

More information

International Journal of Research in Computer and Communication Technology, Vol 2, Issue 3, March-2013

International Journal of Research in Computer and Communication Technology, Vol 2, Issue 3, March-2013 Monitoring the efficiency of workflow in industry and secure access using NFC and Ethernet M.RAJESH, C.Saktheeswaran, S.Selva Ganesh Maamallan Institute Of Technology Sriperumbudur,Chennai rash.rocky.91@gmail.com,

More information

RS TechMedic BV the Netherlands T: vision.com

RS TechMedic BV the Netherlands T: vision.com Dyna Vision Remote Patient Monitoring: Demonstration of Real Time 12 lead ECG Acquisition and Waveform Analysis using Integrated Cellular Transmission Telemonitoring Session Med e Tel 2010 Definitions

More information

COMMUNICATION AND INTEGRATION OF HEALTH RELATED DATA IN ELECTRONIC HEALTH RECORDS USING INTERNATIONAL MEDICAL STANDARDS

COMMUNICATION AND INTEGRATION OF HEALTH RELATED DATA IN ELECTRONIC HEALTH RECORDS USING INTERNATIONAL MEDICAL STANDARDS COMMUNICATION AND INTEGRATION OF HEALTH RELATED DATA IN ELECTRONIC HEALTH RECORDS USING INTERNATIONAL MEDICAL STANDARDS Burgsteiner H 1, Sabutsch S 1, Kollmann A 2, Morak J 2 Abstract Electronic Health

More information

Integrating a mobile health setup in a chronic disease management network

Integrating a mobile health setup in a chronic disease management network Integrating a mobile health setup in a chronic disease management network Hang Ding, Derek, Ireland, Rajiv Jayasena, Jamie Curmi, and Mohan Karunanithi. Presenter: Hang Ding (hang.ding@csiro.au) THE AUSTRALIAN

More information

NFC is the double click in the internet of the things

NFC is the double click in the internet of the things NFC is the double click in the internet of the things Name Frank Graeber, Product Manager NFC Subject 3rd Workshop on RFID Systems and Technologies Date 12.06.2007 Content NFC Introduction NFC Technology

More information

BANGLADESH UNIVERSITY OF ENGINEERING & TECHNOLOGY (BUET) DHAKA TECHNICAL SPECIFICATION FOR SUPPLY AND INSTALLATION OF LABORATORY EQUIPMENTS (PKG1).

BANGLADESH UNIVERSITY OF ENGINEERING & TECHNOLOGY (BUET) DHAKA TECHNICAL SPECIFICATION FOR SUPPLY AND INSTALLATION OF LABORATORY EQUIPMENTS (PKG1). BANGLADESH UNIVERSITY OF ENGINEERING & TECHNOLOGY (BUET) DHAKA TECHNICAL SPECIFICATION FOR SUPPLY AND INSTALLATION OF LABORATORY EQUIPMENTS (PKG1). Package number: G4 NO: HEQEP/CP-3137/Procurement/PacakageG4/26-08-2015/004

More information

Healthcare to go. WAC, Katarzyna, BULTS, Richard. Abstract

Healthcare to go. WAC, Katarzyna, BULTS, Richard. Abstract Article Healthcare to go WAC, Katarzyna, BULTS, Richard Abstract A combination of very local and very long-distance wireless networks is bringing remote personal health Reference WAC, Katarzyna, BULTS,

More information

Transmission of IPv6 Packets over Near Field Communication

Transmission of IPv6 Packets over Near Field Communication Transmission of IPv6 Packets over Near Field Communication draft-hong-6lo-ipv6-over-nfc-00.txt Y. Hong, Y. Choi (ETRI), J. Youn (DONG-EUI Univ.), D. Kim (KNU) JH. Choi (Samsung) 6lo WG Meeting@IETF 90

More information

Wireless C45 Based Vital-Signs Monitoring System for Patient after Heart Operation Care

Wireless C45 Based Vital-Signs Monitoring System for Patient after Heart Operation Care Wireless C45 Based Vital-Signs Monitoring System for Patient after Heart Operation Care S.NOIMANEE*, T.TUNKASIRI**, K.SIRIWITAYAKORN**, J.TUNTRAKOON** * Department of Computer Engineering, Biomedical Engineering

More information

Study ON Remote Medical Monitoring System Based ON MSP430 AND CC2530

Study ON Remote Medical Monitoring System Based ON MSP430 AND CC2530 2nd International Conference on Electrical, Computer Engineering and Electronics (ICECEE 2015) Study ON Remote Medical Monitoring System Based ON MSP430 AND CC2530 SONG Aijuan, SI Guangyuan, GU Qiongchan

More information

Connecting to the future ELATEC RFID SYSTEMS

Connecting to the future ELATEC RFID SYSTEMS Connecting to the future ELATEC RFID SYSTEMS ELATEC GmbH Enabling success RFID SYSTEMS Focus on the goal Adaptable to our customer s requirements, Elatec products and technologies are the core that has

More information

Human heart rate detector based on photoelectric volume

Human heart rate detector based on photoelectric volume Abstract Human heart rate detector based on photoelectric volume Jian Du, Jie Hu Southwest Petroleum University, Chengdu 610500, China. At present, the most effective and intuitionistic method for detecting

More information

ET16 Continuous Vital Signs Monitoring using Smartphones

ET16 Continuous Vital Signs Monitoring using Smartphones ET16 Continuous Vital Signs Monitoring using Smartphones Nazrul Anuar Nayan, Faizatul Azwa Azami Department of Electrical, Electronic and System Engineering, Faculty of Engineering and Built Environment,

More information

IEEE PROJECTS ON EMBEDDED SYSTEMS

IEEE PROJECTS ON EMBEDDED SYSTEMS S.NO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 PROJECT TITLES EMACS: Design And Implementation Of Indoor Environment Monitoring And Control System VOT-EL: Three Tier Secured State Of

More information

Microcontroller Unit (MCU) Block Data Sheet

Microcontroller Unit (MCU) Block Data Sheet Microcontroller Unit (MCU) MCU 140616 SPECIFICATIONS > Sampling Rate: 1, 10, 100 or 1000Hz > Analog Ports: 6 in (A1-A6) + 1 out (PWM) > Digital Ports: 2 in (I1&I2) + 2 out (O1&O2) > Auxiliary Ports: 1

More information

PhysioLab Product Guide

PhysioLab Product Guide co., Ltd. www.physiolab.co.kr Product Guide Biosignal measurement & monitoring Electrochemical measurement BME-KIT Experimental kit to train biosignal measurement Assemble KIT ECG-KIT PPG-KIT EMG-KIT Test

More information

Android & Medical system February 15th, Diego Buffa, System Engineer

Android & Medical system February 15th, Diego Buffa, System Engineer Android & Medical system February 15th, 2012 Diego Buffa, System Engineer Agenda Android in Medical too? Context Standards Use Cases It works! 2 Android devices are entering a complex environment 3 Previously...

More information

TelehealthSolution: Portable Pulse Oximeter

TelehealthSolution: Portable Pulse Oximeter TelehealthSolution: Portable Pulse Oximeter The advancements in technology and connectivity open up previously unexplored avenues in the field of personal health monitoring. It is indeed true that prevention

More information

edify Requirements for Evidence-based Templates in Electronic Case Report Forms Marco Schweitzer, Stefan Oberbichler

edify Requirements for Evidence-based Templates in Electronic Case Report Forms Marco Schweitzer, Stefan Oberbichler edify Requirements for Evidence-based Templates in Electronic Case Report Forms Marco Schweitzer, Stefan Oberbichler ehealth Research and Innovation Unit, UMIT - University for Health Sciences, Medical

More information

Application of Android Mobile Platform in Remote Medical Monitoring System

Application of Android Mobile Platform in Remote Medical Monitoring System Application of Android Mobile Platform in Remote Medical Monitoring System Prof D Somashekara Reddy 1, Lokesh G 2 1,2 Master of Computer Applications, NHCE Bengaluru Abstract : Due to the actual demand

More information

Remotely Accessible Healthcare at Home. User Guide for Devices

Remotely Accessible Healthcare at Home. User Guide for Devices RAH@H A Patient Centric 24/7 Connected Health Model to Improve Healthcare Outcomes through Technology for Education, Engagement, Empowerment, Monitoring & Treatment of Patients Virtually User Guide for

More information

The following use cases were developed by the Connected Living Programme in 2014/15:

The following use cases were developed by the Connected Living Programme in 2014/15: Connected Living Programme Future IoT Networks IoT Use Case Summary The following use cases were developed by the Connected Living Programme in 2014/15: A.1.1 Healthcare Remote Glucose Monitoring: a blood

More information

Join the forward thinkers who rely on Toshiba for wireless connectivity ICs.

Join the forward thinkers who rely on Toshiba for wireless connectivity ICs. ELECTRONIC COMPONENTS Wireless Communication Solutions Join the forward thinkers who rely on Toshiba for wireless connectivity ICs. Bluetooth Low Power Near Field Communications High Speed Wireless Power

More information

Device Equivalence Evaluation Form

Device Equivalence Evaluation Form Comparison with BRAUN BUA7200 and AViTA BPM64 Devices Item 9 BRAUN BUA7200 AViTA BPM64 Pictures Display image Full-colour TFT-LCD dot matrix display with bitmap graphics that change with context. Some

More information

Cemetery Navigation and Information Query System Based on Android and Java Web

Cemetery Navigation and Information Query System Based on Android and Java Web 2017 3rd International Conference on Computational Systems and Communications (ICCSC 2017) Cemetery Navigation and Information Query System Based on Android and Java Web Chao Ding1, a, Yongjie Yang1, b,

More information

NEAR FIELD COMMUNICATION

NEAR FIELD COMMUNICATION NEAR FIELD COMMUNICATION (GUIDED BY:MISS ANUJA V NAIR) BY: REJOY MENDEZ ROLL NO:24 S7 ECE OVERVIEW INTRODUCTION FEATURES OF NFC TECHNOLOGICAL OVERVIEW COMPARISON WITH OTHER TECHNOLOGY SECURITY ASPECTS

More information

A Proposed e-payment Service for Visually Disabled

A Proposed e-payment Service for Visually Disabled IJCSNS International Journal of Computer Science and Network Security, VOL.17 No.5, May 2017 253 A Proposed e-payment Service for Visually Disabled Gamal H. Eladl 1 1 Information Systems Department, Faculty

More information

Tiny sample. Huge insights. Eurolyser Point-of-Care Systems

Tiny sample. Huge insights. Eurolyser Point-of-Care Systems Tiny sample Huge insights Eurolyser Point-of-Care Systems instruments The elegant and carefree desktop laboratory These small, elegant and reliable point-of-care analysers were designed with practises

More information

An IoT-Aware Architecture for Smart

An IoT-Aware Architecture for Smart An IoT-Aware Architecture for Smart Healthcare System Presented By: Amnah Allboani Abstract Smart hospital system (SHS) relies on complementary technologies specifically RFID, WSN, and smart mobile, interoperating

More information

Weared Data; the Personal and Proprietary Nature of Data on Wearable Technology Devices. Dr. Michael Conyette

Weared Data; the Personal and Proprietary Nature of Data on Wearable Technology Devices. Dr. Michael Conyette Weared Data; the Personal and Proprietary Nature of Data on Wearable Technology Devices Dr. Michael Conyette Contents Rising demand for wearables. Driving factors for adoption. Changing marketplace for

More information

Recording Vital Signs and Test Results in Med-Center

Recording Vital Signs and Test Results in Med-Center Recording Vital Signs and Test Results in Med-Center Introduction This technical note discusses Med-Center s ability to record and plot lab test results or patient vital signs. This capability is a new

More information

HOW SENSOR FRAMEWORKS ENABLE EFFICIENT DEVELOPMENT

HOW SENSOR FRAMEWORKS ENABLE EFFICIENT DEVELOPMENT HOW SENSOR FRAMEWORKS ENABLE EFFICIENT DEVELOPMENT SHUBHADIP PAUL SOFTWARE ENGINEER SEMICON EUROPA 2017 16, NOVEMBER, 2017 Remote Sensors in an IoT Ecosystem Cloud Service BLE / Thread Smart Camera Wi-Fi

More information

Mobile Wireless Sensor Network enables convergence of ubiquitous sensor services

Mobile Wireless Sensor Network enables convergence of ubiquitous sensor services 1 2005 Nokia V1-Filename.ppt / yyyy-mm-dd / Initials Mobile Wireless Sensor Network enables convergence of ubiquitous sensor services Dr. Jian Ma, Principal Scientist Nokia Research Center, Beijing 2 2005

More information

Lecture 20: Future trends in mobile computing. Mythili Vutukuru CS 653 Spring 2014 April 7, Monday

Lecture 20: Future trends in mobile computing. Mythili Vutukuru CS 653 Spring 2014 April 7, Monday Lecture 20: Future trends in mobile computing Mythili Vutukuru CS 653 Spring 2014 April 7, Monday Future topics Improving capacity Dynamic spectrum access Massive MIMO Heterogeneous networks Pervasive

More information

Wireless Wearable Electrocardiogram (WWECG) Ulbert Joey Botero EE Alexander Consunji CpE Ryan Shifman EE Karson Kimbrel CS Group 18

Wireless Wearable Electrocardiogram (WWECG) Ulbert Joey Botero EE Alexander Consunji CpE Ryan Shifman EE Karson Kimbrel CS Group 18 Wireless Wearable Electrocardiogram (WWECG) Ulbert Joey Botero EE Alexander Consunji CpE Ryan Shifman EE Karson Kimbrel CS Group 18 Project Overview The Wireless Wearable Electrocardiogram is a portable

More information

Mobile ECG. A new ehealth solution for telecardiology based on ehit Health Gateway platform. Kalevi Voutilainen, March 2008

Mobile ECG. A new ehealth solution for telecardiology based on ehit Health Gateway platform. Kalevi Voutilainen, March 2008 A new ehealth solution for telecardiology based on ehit Health Gateway platform Kalevi Voutilainen, March 2008 Fact sheet Founded 1995 Location Kuopio, Finland Ownership 100 % privately owned Employees

More information

HOW TO INTEGRATE NFC CONTROLLERS IN LINUX

HOW TO INTEGRATE NFC CONTROLLERS IN LINUX HOW TO INTEGRATE NFC CONTROLLERS IN LINUX JORDI JOFRE NFC READERS NFC EVERYWHERE 28/09/2017 WEBINAR SERIES: NFC SOFTWARE INTEGRATION PUBLIC Agenda NFC software integration webinar series Session I, 14th

More information

Title: Bringing Health and Fitness Data Together for Connected Healthcare: Mobile Apps as Enablers of Interoperability. Abstract

Title: Bringing Health and Fitness Data Together for Connected Healthcare: Mobile Apps as Enablers of Interoperability. Abstract Please cite as: Gay V, Leijdekkers P Bringing Health and Fitness Data Together for Connected Health Care: Mobile Apps as Enablers of Interoperability, J Med Internet Res 2015;17(11):e260 DOI: 10.2196/jmir.5094

More information

Android & Medical systems

Android & Medical systems Android & Medical systems November 15th, 2011 Stephane Strahm, Prog. Mgr Android Center of Excellence Agenda Android in Medical too? Context Standards Use Cases It works! 2 2009 Wind River. All Rights

More information

An open-source, multi-parameter, full fledged human body vital sign monitoring HAT for Raspberry Pi as well as standalone use.

An open-source, multi-parameter, full fledged human body vital sign monitoring HAT for Raspberry Pi as well as standalone use. HealthyPi v3 An open-source, multi-parameter, full fledged human body vital sign monitoring HAT for Raspberry Pi as well as standalone use. HealthyPi is the first fully open-source, full-featured vital

More information

Intelligent Patient Monitoring System Using Smart Phone Based Technology

Intelligent Patient Monitoring System Using Smart Phone Based Technology Intelligent Patient Monitoring System Using Smart Phone Based Technology Vivek Doke 1, Vishal Gaje 1, Manoj Kalambe 1, Rakesh Nalawade 1 Final Year B.E Student, Dept. of Computer Engineering, P.E.S. s

More information

DEVICE-TO-DEVICE COMMUNICATION VIA NFC

DEVICE-TO-DEVICE COMMUNICATION VIA NFC DEVICE-TO-DEVICE COMMUNICATION VIA NFC JORDI JOFRE NFC READERS NFC EVERYWHERE 07/03/2017 WEBINAR SERIES: HOW TO BUILD NFC APPLICATIONS PUBLIC Agenda Device-to-device communication demo Demo functionality

More information

The Evolving Role of Primary Care and Technology in Cardiology

The Evolving Role of Primary Care and Technology in Cardiology The Evolving Role of Primary Care and Technology in Cardiology Peter Tilkemeier, MD, MMM, FACC Chair, Department of Medicine Greenville Health System Professor, University of South Carolina School of Medicine

More information

Suggestions for Visualising Physical Hyperlinks. Pasi Välkkynen PERMID Workshop, Dublin, May

Suggestions for Visualising Physical Hyperlinks. Pasi Välkkynen PERMID Workshop, Dublin, May Suggestions for Visualising Physical Hyperlinks Pasi Välkkynen PERMID Workshop, Dublin, May 7 2006 Contents Physical browsing and physical selection Visualisation challenges in physical browsing Visualisations

More information

Wireless interactive system for patient healthcare monitoring using mobile computing devices

Wireless interactive system for patient healthcare monitoring using mobile computing devices University of Wollongong Research Online Faculty of Informatics - Papers (Archive) Faculty of Engineering and Information Sciences 2008 Wireless interactive system for patient healthcare monitoring using

More information

Transfer of Physiological Signals: Application for Patients with Chronic Diseases in their Home

Transfer of Physiological Signals: Application for Patients with Chronic Diseases in their Home International Journal of Engineering Inventions e-issn: 2278-7461, p-issn: 2319-6491 Volume 4, Issue 7 (December 2014) PP: 20-27 Transfer of Physiological Signals: Application for Patients with Chronic

More information

2017 2nd International Conference on Information Technology and Management Engineering (ITME 2017) ISBN:

2017 2nd International Conference on Information Technology and Management Engineering (ITME 2017) ISBN: 2017 2nd International Conference on Information Technology and Management Engineering (ITME 2017) ISBN: 978-1-60595-415-8 Design and Implementation of a Mobile Healthcare Management Platform Based on

More information

H3 System Tele-Healthcare Solution Wearable Sensors. April. 2018

H3 System Tele-Healthcare Solution Wearable Sensors. April. 2018 H3 System Tele-Healthcare Solution Wearable Sensors April. 2018 Table of Contents I. Company Introduction II. Tele-Healthcare Solution 1. Service Delivery Model 2. Selected Customers 3. Technology Overview

More information

1. Download the PTS Connect ProLink desktop hub installer from the PTS Connect ProLink web platform and run the installer. The following screen will

1. Download the PTS Connect ProLink desktop hub installer from the PTS Connect ProLink web platform and run the installer. The following screen will PS-005508 EN Rev. 0 01/18 User Guide 1 Requirements The minimum requirements for using the PTS Connect ProLink desktop platform are as follows: PC: Operating System: Microsoft Windows 10 (64 bits) Specifications:

More information

Life Sensing Technology LIFELOG. v1.0 EN Effective From 5 October 2016

Life Sensing Technology LIFELOG. v1.0 EN Effective From 5 October 2016 Life Sensing Technology LIFELOG v1.0 EN Effective From 5 October 2016 1 LIFELOG Everyday thousands and thousands of locations, itineraries, heart rates, blood pressure values, breath rates, ecg videos,

More information

SBCSC Staff BYOD (bring your own device) Instructions: 08/11/2016

SBCSC Staff BYOD (bring your own device) Instructions: 08/11/2016 SBCSC Staff BYOD (bring your own device) Instructions: 08/11/2016 Teachers and staff, use these instructions to get a personal device of yours attached to the SBCSC BYOD wireless network. Once connected,

More information

RFID INTERFACES. Documentation iid POCKETwork. RFID read write unit HF or UHF with Bluetooth(TM) interface

RFID INTERFACES. Documentation iid POCKETwork. RFID read write unit HF or UHF with Bluetooth(TM) interface RFID INTERFACES Documentation iid POCKETwork RFID read write unit HF or UHF with Bluetooth(TM) interface microsensys 2014 Contact/Copyright microsensys GmbH Office Park im GVZ In der Hochstedter Ecke 2

More information

Bluetooth mobile solutions APPLICATION NOTE / FAQ. Page 1 on 24

Bluetooth mobile solutions APPLICATION NOTE / FAQ. Page 1 on 24 Bluetooth mobile solutions APPLICATION NOTE / FAQ Page 1 on 24 Table of Contents I. Introduction... 5 II. Bluetooth Smart technology General principles... 5 III. Frequently Asked Questions... 5 A. STid

More information

RT1025 Cardio EVK User Manual

RT1025 Cardio EVK User Manual Cardio EVK for RT1025 Cardioid Evaluation Board Purpose The RT1025 is an integrated AFE solution for Heart-Rate monitoring and Biopotential measurements. The RT1025 integrates low noise voltage and current

More information

Regulation and the Internet of Things

Regulation and the Internet of Things Regulation and the Internet of Things 15 th Global Symposium for Regulators (GSR15) Prof. Ian Brown The views expressed in this presentation are those of the author and do not necessarily reflect the opinions

More information

DynaPulse DP5200A Pathway (USB & Bluetooth) Hardware Instruction Quick Guide

DynaPulse DP5200A Pathway (USB & Bluetooth) Hardware Instruction Quick Guide DynaPulse DP5200A Pathway (USB & Bluetooth) Hardware Instruction Quick Guide Thank you for choosing DynaPulse DP5200A/Pathway noninvasive blood pressure monitoring system. Please read this instruction

More information

Transmitting Patient Vitals Over a Reliable ZigBee Mesh Network

Transmitting Patient Vitals Over a Reliable ZigBee Mesh Network Accepted at the 2014 IEEE Canada International Humanitarian Technology Conference (IHTC). Transmitting Patient Vitals Over a Reliable ZigBee Mesh Network Reza Filsoof, Alison Bodine, Bob Gill, Stephen

More information

Mobile App Help File

Mobile App Help File Mobile App Help File Contents 2 Contents Introduction... 4 OneTouch Reveal mobile app... 4 Supported Devices and System Requirements...4 Apple Legal Notice...4 Bluetooth Trademark...4 Intended Use...4

More information

STEP 6: USING THE VITALSBRIDGE WITH A STANDARDIZED PATIENT VITALSBRIDGE AND 100

STEP 6: USING THE VITALSBRIDGE WITH A STANDARDIZED PATIENT VITALSBRIDGE AND 100 STEP 6: USING THE VITALSBRIDGE WITH A STANDARDIZED PATIENT VITALSBRIDGE 300 200 AND 100 Overview: Before beginning this segment make sure the following have been completed: o The VitalsBridge has been

More information

Dual Interface EEPROM

Dual Interface EEPROM Dual Interface EEPROM Evaluation kits and boards 2 I²C interface EEPROM RF interface 3 Evaluation kits Evaluation kits 4 Demonstration kit Development kit Purpose Evaluation, proof-of-concept Development,

More information

ONLINE REAL TIME HEALTH MONITORING OF PATIENT USING INTRABODY COMMUNICATION

ONLINE REAL TIME HEALTH MONITORING OF PATIENT USING INTRABODY COMMUNICATION Volume: 03 Issue: 12 Dec -2016 www.irjet.net p-issn: 2395-0072 ONLINE REAL TIME HEALTH MONITORING OF PATIENT USING INTRABODY COMMUNICATION Kirti Thosar 1, Geetha Narayanan 2 1P.G. Student, Department of

More information

Continua Guidelines CESL and Test Tool Development

Continua Guidelines CESL and Test Tool Development Continua Guidelines CESL and Test Tool Development Monday, February 4 th, 2013 Combined this represents over $2M worth of code that Continua has created to enable complete E2E functionality and all of

More information

Die Zukunft des M-Payment The future of m-payment NFC. Andreas Johne. Düsseldorf, 25. Januar 2008

Die Zukunft des M-Payment The future of m-payment NFC. Andreas Johne. Düsseldorf, 25. Januar 2008 Die Zukunft des M-Payment Düsseldorf, 25. Januar 2008 Andreas Johne Agenda Brief company presentation M-payment with Near Field Communication Success stories with Page 2 Giesecke & Devrient From Printing

More information

GSM BASED TELEALERT SYSTEM

GSM BASED TELEALERT SYSTEM RESEARCH ARTICLE OPEN ACCESS GSM BASED TELEALERT SYSTEM Prerana G. Patil*, S. D. Sawant** *(Department of Electronics and Telecommunication, GSM college of Enginnering, Savitribai Phule Pune University,

More information

Mobile Security Fall 2011

Mobile Security Fall 2011 Mobile Security 14-829 Fall 2011 Patrick Tague Class #9 Smartphones, PANs, and the IoT Announcements HW #2 will be posted this week Project group meetings: I'd like to schedule a meeting with each group

More information

Security in NFC Readers

Security in NFC Readers Security in Readers Public Content and security, a different kind of wireless Under the hood of based systems Enhancing the security of an architecture Secure data exchange Information security goals Cryptographic

More information

FDA CDRH perspective on new technologies in inhaler products

FDA CDRH perspective on new technologies in inhaler products 2017 IPAC RS/ISAM Joint Workshop New Frontiers in Inhalation Technology FDA CDRH perspective on new technologies in inhaler products Linda Ricci Associate Director ODE DH Office of Device Evaluation Center

More information

Congratulations on the purchase of your new Clover Mobile

Congratulations on the purchase of your new Clover Mobile Congratulations on the purchase of your new Clover Mobile Set Up the Hardware What s included Optional Accessories USB wall charger USB cable Clover Mobile Dock Clover Mobile Printer Clover Mobile Clover

More information

Automating Unpredictable Processes:

Automating Unpredictable Processes: Automating Unpredictable Processes: Building Responsive Apps using Business Rules By Carl Hewitt, Chief Architect, Decisions and Heath Oderman, CTO, Decisions Copyright 2016 Building Responsive Apps: Comparing

More information

Wireless Blood Pressure Monitor (BP5)

Wireless Blood Pressure Monitor (BP5) EN Wireless Blood Pressure Monitor (BP5) QUICK START GUIDE First Time Set Up Instructions Download the Free ihealth MyVitals App For ios devices: Prior to first use, download and install "ihealth MyVitals"

More information

S ENIOR C A PSTONE PROJECT Computer Science Department, Texas Christian University

S ENIOR C A PSTONE PROJECT Computer Science Department, Texas Christian University S ENIOR C A PSTONE PROJECT 2 0 1 3-2014 0 5 /01/14 Team Stockton Ackermann Documentation Lead and Android Application Developer Nicholas Capurso Project Lead, Android Application Developer, and Network

More information

WEARABLE SAFETY WRISTBAND DEVICE FOR ELDERLY HEALTH MONITORING

WEARABLE SAFETY WRISTBAND DEVICE FOR ELDERLY HEALTH MONITORING Int. J. Chem. Sci.: 14(S3), 2016, 829-834 ISSN 0972-768X www.sadgurupublications.com WEARABLE SAFETY WRISTBAND DEVICE FOR ELDERLY HEALTH MONITORING L. K. HEMA *, T. C. KRISHNANUNNI, V. K. ABDUL MAJID and

More information

Lintronix IoT Starter Kit User s Guide Real-time Locating and Telesensing System RTLX-SK /05/01

Lintronix IoT Starter Kit User s Guide Real-time Locating and Telesensing System RTLX-SK /05/01 Lintronix IoT Starter Kit User s Guide Realtime Locating and Telesensing System RTLXSK01 2017/05/01 Lintronix IoT Starter Kit Realtime Locating and Telesensing System RTLSSK01 User s Guide Content Chapter

More information

MySignals SW. ehealth and Medical IoT Development Platform. Technical Guide

MySignals SW. ehealth and Medical IoT Development Platform. Technical Guide MySignals SW ehealth and Medical IoT Development Platform Technical Guide Index Document version: v4.0-09/2017 Libelium Comunicaciones Distribuidas S.L. INDEX 1. MySignals Software Development Platform...4

More information

HEALTH KIT USER GUIDE

HEALTH KIT USER GUIDE HEALTH KIT USER GUIDE HEALTH KIT USER GUIDE Version 7.0 TABLE OF CONTENTS INTRODUCTION... 1-4 Understanding the Tablet... 2 Requesting a Call... 3-4 GETTING STARTED... 5-7 Turning on the Tablet... 5 Accepting

More information

Affordable Smart Health Accessory

Affordable Smart Health Accessory Affordable Smart Health Accessory Keeping it Smart and Simple Table of Contents What is +... 1 + Features... 1 Using +... 2 Key Highlights... 2 Usage Scenarios... 3 Specifications... 3 + App... 4 Portfolio...

More information

Digital Signature Records for the NFC Data Exchange Format

Digital Signature Records for the NFC Data Exchange Format Digital Signature Records for the NFC Data Exchange Format Michael Roland Upper Austria University of Applied Sciences,, Austria 2 nd International Workshop on Near Field Communication 20 April 2010, Monaco

More information

Firmware Update 3.0 MSA G1 SCBA

Firmware Update 3.0 MSA G1 SCBA Firmware Update 3.0 MSA G1 SCBA The MSA G1 SCBA was developed with the promise to provide continuous advancements in technology. Fulfilling that promise, MSA is pleased to announce the release of the G1

More information

Kostas Giokas MONITORING OF COMPLIANCE ON AN INDIVIDUAL TREATMENT THROUGH MOBILE INNOVATIONS

Kostas Giokas MONITORING OF COMPLIANCE ON AN INDIVIDUAL TREATMENT THROUGH MOBILE INNOVATIONS Kostas Giokas MONITORING OF COMPLIANCE ON AN INDIVIDUAL TREATMENT THROUGH MOBILE INNOVATIONS AIM RESEARCH TEAM BIOMEDICAL ENGINEERING LABORATORY NATIONAL TECHNICAL UNIVERSITY OF ATHENS WHAT IS MHEALTH?

More information

DYNAMIC DECISIONS IN MAINTENANCE

DYNAMIC DECISIONS IN MAINTENANCE DYNAMIC DECISIONS IN MAINTENANCE Wireless Communication... As a support of Component Integration [DWC 15, 16, 17, 18] University Henri Poincaré (Nancy University) PRISMA Wyselec Wireless - Problem Statement

More information

NEAR FIELD COMMUNICATION - THE FUTURE TECHNOLOGY FOR AN INTERACTIVE WORLD

NEAR FIELD COMMUNICATION - THE FUTURE TECHNOLOGY FOR AN INTERACTIVE WORLD Int. J. Engg. Res. & Sci. & Tech. 2013 Jignesh Patel and Badal Kothari, 2013 Research Paper ISSN 2319-5991 www.ijerst.com Vol. 2, No. 2, May 2013 2013 IJERST. All Rights Reserved NEAR FIELD COMMUNICATION

More information

ValiPak / ValiPak TOUCH. The validatable ValiPak and ValiPakTOUCH bar sealers for The packaging of pouches and reels.

ValiPak / ValiPak TOUCH. The validatable ValiPak and ValiPakTOUCH bar sealers for The packaging of pouches and reels. ValiPak / ValiPak TOUCH The validatable ValiPak and ValiPakTOUCH bar sealers for The packaging of pouches and reels. ValiPak / ValiPak TOUCH hd 380 WSI-V ValiPak hd 480 WSI-V ValiPak TOUCH The validatable,

More information

Data Collector by Using Wireless Technologies IEEE and Bluetooth

Data Collector by Using Wireless Technologies IEEE and Bluetooth Data Collector by Using Wireless Technologies IEEE 802.15.4 and Bluetooth KSV Pavan Kumar 1, R.Srinivasa Rao 2 1 Scholars, KITS, Khammam, India 2 Associate Professor, KITS, Khammam, India E-Mail- pavan101088@gmail.com

More information

Bluetooth Low Energy (BLE) Based Mobile Electrocardiogram Monitoring System

Bluetooth Low Energy (BLE) Based Mobile Electrocardiogram Monitoring System Proceeding of the IEEE International Conference on Information and Automation Shenyang, China, June 2012 Bluetooth Low Energy (BLE) Based Mobile Electrocardiogram Monitoring System Bin Yu and Lisheng Xu

More information

Current Benefits and Future Directions of NFC Services

Current Benefits and Future Directions of NFC Services Current Benefits and Future Directions of NFC Services Kerem OK, Vedat COSKUN, Mehmet N. AYDIN, and Busra OZDENIZCI Department of Information Technologies, ISIK University Istanbul, Turkey { keremok vedatcoskun

More information

MedCheck App User Guide for Blood Pressure Monitor

MedCheck App User Guide for Blood Pressure Monitor MedCheck App User Guide for Blood Pressure Monitor Sign Up Select User in first screen after app has been installed and opened for first time. Click Register in login page, enter details to register. Click

More information

Connection Guide (for COOLPIX)

Connection Guide (for COOLPIX) Connection Guide (for COOLPIX) This document describes the procedure for using the SnapBridge app (Version 2.0) to establish a wireless connection between a supported camera and smart device. When you

More information

Use Cases for Argonaut Project -- DRAFT Page

Use Cases for Argonaut Project -- DRAFT Page Use Cases for Argonaut Project -- DRAFT Page 1 Use Cases for Argonaut Project DRAFT V0.3 March 03, 2015 Use Cases for Argonaut Project -- DRAFT Page 2 Introduction The Argonaut Project seeks to rapidly

More information

Dual Interface EEPROM. December 2011

Dual Interface EEPROM. December 2011 Dual Interface EEPROM Product presentation December 2011 Dual Interface EEPROM Introduction New MCU control function Low-power I2C interface RFID and NFC compatible RF interface Unique Energy Harvesting

More information

Design of an Automatic Fare Collection System Using Near Field Communication with Focus on Indian Metrorail

Design of an Automatic Fare Collection System Using Near Field Communication with Focus on Indian Metrorail International Journal of Engineering Research and Development e-issn: 2278-067X, p-issn: 2278-800X, www.ijerd.com Volume 10, Issue 4 (April 2014), PP.20-24 Design of an Automatic Fare Collection System

More information

WPAN/WBANs: ZigBee. Dmitri A. Moltchanov kurssit/elt-53306/

WPAN/WBANs: ZigBee. Dmitri A. Moltchanov    kurssit/elt-53306/ WPAN/WBANs: ZigBee Dmitri A. Moltchanov E-mail: dmitri.moltchanov@tut.fi http://www.cs.tut.fi/ kurssit/elt-53306/ IEEE 802.15 WG breakdown; ZigBee Comparison with other technologies; PHY and MAC; Network

More information

PAN1740 Design Guide

PAN1740 Design Guide 1 of 14 PAN1740 2 of 14 TABLE OF CONTENTS 1. Scope of this Document... 3 2. Key benefits when using PAN1740... 3 3. Bluetooth Low Energy... 3 4. Description PAN1740... 4 5. Block Diagram PAN1740 Module...

More information

Performance of Smartphones while scanning low power Bluetooth Smart Beacons

Performance of Smartphones while scanning low power Bluetooth Smart Beacons Performance of Smartphones while scanning low power Bluetooth Smart Beacons (Presented at Embedded Computing Conference Winterthur, 5 th of September 2017) Cornel Brülisauer, Philipp Bachmann, Marcel Meli

More information

Smart Card meets Connectivity New Opportunities in Mobile Business with NFC Technology. Smart Card Alliance2005 Fall Annual Conference Martin Bührlen

Smart Card meets Connectivity New Opportunities in Mobile Business with NFC Technology. Smart Card Alliance2005 Fall Annual Conference Martin Bührlen Smart Card meets Connectivity New Opportunities in Mobile Business with NFC Technology Smart Card Alliance2005 Fall Annual Conference Martin Bührlen Agenda NFC Technology Use Cases Implications for the

More information

VIS_ZM1602 Wireless Siren - mainspowered

VIS_ZM1602 Wireless Siren - mainspowered Image not readable or empty images/manufacturers/vision.png VIS_ZM1602 Wireless Siren - mainspowered Firmware Version : 1.65 Quick Start A This device is a wireless Z-Wave actor. For Inclusion and Exclusion

More information

ulrich medical Tourniquets

ulrich medical Tourniquets ulrich medical Tourniquets Combining ease of use with safety Secure application with 2 clicks Tourniquets 1 100 years of reliability and German precision Tourniquets by ulrich medical stand for quality

More information

RELATIONSHIP WITH KONICA MINOLTA

RELATIONSHIP WITH KONICA MINOLTA JOHN ENJOY DOE A FLEXIBLE INC. ENJOYS MOBILE TRUSTFUL WORKSTYLE RELATIONSHIP WITH KONICA MINOLTA Global technology leader profits from document security, lower costs, greener printing and the same level

More information

Performing real-time BCI experiments

Performing real-time BCI experiments Performing real-time BCI experiments g.tec medical engineering GmbH Herbersteinstr. 60 8020 Graz, Austria www.gtec.at guger@gtec.at g.usbamp is a biosignal acquisition system for EEG, ECG, EMG, EOG and

More information

MBHB Smart Running Watch

MBHB Smart Running Watch MBHB Smart Running Watch Before Use, You Need To Know: Before use, please kindly take about 3 hours for fully charged. How to charge it Align the ejector pin of the charging clamp with the charge contact

More information