The Pieces to Managing FCoE John Crandall Brocade

Size: px
Start display at page:

Download "The Pieces to Managing FCoE John Crandall Brocade"

Transcription

1 The Pieces to Managing FCoE John Crandall Brocade

2 Abstract This presentation will identify and provide an overview to the many implementation pieces a client and FCoE switch and CNA vendor may need to consider for managing an FCoE environment including discovery and configuration. These pieces may include standards from the SNIA, DMTF, and T11. The presentation will attempt to identify the possible gaps in these standards and how they may be addressed and will also examine whether a client can hooks all these pieces together and if so how? 2

3 Learning Objectives What are the current and future management standards How do you hook the pieces together What are the gaps and how might they be addressed 3

4 Agenda T11 SM-HBA II FC-GS SNIA SMI DMTF FC HBA Diagnostics SVPC Virtual Networks 4

5 SM-HBA-II

6 Terminology Translation Bus Address variants for different standard buses HBA HBA handle, manufacturer,model #, serial #, firmware version,... # of Ports 0-n 1 1 Physical HBA PHBA handle, manufacturer, model #, serial #, # Ports Bold borders: physical objects Fabric/VN_Port Fabric/Nx_Port VF_ID, in-order delivery, Fabric Fabric name VFID, inorder, VFID mask 0-n Fabric/PN_Port Fabric/Phy 0-n VN_Port FC Port index, Port name, Port address, Fabric name,... # of Phys=1 0-n VFID Mask, Port VFID PN_Port FC Phy 0-n 0-n Phy index, speed, topology, physical attributes 1 0-n n 1 1 Protocol FC-4 statistics FC-4 TYPE, I/O counters: Input operations, output operations, control operations VN_Port statistics traffic counters: frames, words PN_Port Phy statistics traffic counters: frames, words link error counters

7 What needs to be added FCoE_LEPs VN_Port MAC address/vlan ID and FCF-MAC address Lossless Ethernet MACs Physical attributes, e.g., speed FCoE Controllers ENode MAC address FC-BB_E VLAN mask 7

8 Adding FCoE into the SM-HBA-2 Architecture Bus Address variants for different standard buses HBA HBA handle, manufacturer,model #, serial #, firmware version,... # of Ports 0-n 1 1 Physical HBA PHBA handle, manufacturer, model #, serial #, # Ports Bold borders: physical objects Fabric/VN_Port VF_ID, in-order delivery, 0-n Fabric/PHY 0-n Port Port index, Port name, Port address, Fabric name,... # of Phys=1 0-n VFID Mask, Port VFID PHY Fabric 0-n 0-n Fabric name Phy index, speed, topology, physical VFID, inorder, attributes VFID mask 1 0-n n 1 1 Protocol statistics FC-4 TYPE, I/O counters: Input operations, output operations, control operations Port statistics traffic counters: frames, words PHY statistics traffic counters: frames, words link error counters

9 Adding FCoE into the SM-HBA-2 Architecture Bus Address variants for different standard buses HBA HBA handle, manufacturer,model #, serial #, firmware version,... # of Ports 0-n 1 1 Physical HBA PHBA handle, manufacturer, model #, serial #, # Ports Bold borders: physical objects Fabric/VN_Port 0-n 0-n VN_Port Port index, Port name, Port address, Fabric name,... # of Phys=1 1 0-n 1 1 VF_ID, in-order Fabric/PHY 0-n FCoE_LEP delivery, VFID Mask, Port VFID Addresses* Fabric FCoE PHY ( Lossless E net MAC) 1-n Fabric name 0-n 0-n Phy index, speed, topology (?), 1 1 VFID, inorder, physical attributes VFID mask 1 Protocol statistics FC-4 TYPE, I/O counters: Input operations, output operations, control operations Port statistics traffic counters: frames, words PHY statistics traffic counters: frames, words link error counters *Addresses: VN_Port MAC, FCF_MAC, VLAN ID 0-n ENode Controller Enode MAC address, FC-BB_E VLAN mask 1 1 FIP statistics traffic counters: frames, words link error counters

10 Additional details From T11/09-530v1 (23 November 2009) by Bob Nixon (Emulex) 10

11 FC-GS-7

12 FC Switching Element and Physical Switch Attributes FC Switching Element Object Physical Switch Object Name Type Domain ID(s) Fabric Name Logical Name Management Address(es) Physical Switch Correlatable Identifier Correlatable Identifier Management Address(es) Vendor Name Model Name Release Code Vendor Specific Info

13 Vx Port and Px Port Attributes Vx Port Object Physical Port Object Name Type Logical Name Attached Port(s) Port State Zoning Enforcement Status Physical Port Correlatable ID Transport Type (FC, FCoE, FCIP, ) Correlatable ID Name Tx Type Module Type Physical Port Number Port State Port Speed Capabilities Port Operating Speed Physical Location

14 Enhanced Fabric Configuration Server Request Command Codes Code (hex) Mnem. Description Attribute(s) in Request CT_IU Attribute(s) in Accept CT_IU 0100 GSL Get Switch List none List of Switch Names 0101 GSAG Get Switch Attribute Group Switch Name A group of attributes for the Switch 0102 GSPL Get Switch Port List Switch Name List of VxPorts 0110 GPSAG Get Physical Switch Attribute Group Physical Switch Name 0111 GPSPL Get Physical Switch Port List Physical Switch Name 0130 GVPAG Get Virtual Port Attribute Group Physical Switch Name, List of Port Names A group of attributes List of PxPorts A group of attributes for the listed ports

15 Enhanced Fabric Configuration Server Request Command Codes Code (hex) Mnem. Description Attribute(s) in Request CT_IU Attribute(s) in Accept CT_IU 0131 GAPL Get Attached Port List Port Name List of Attached Port Names 0140 GPPAG Get Physical Port Attribute Group Physical Switch Name, List of Port Names A group of attributes

16 SNIA SMI

17 Fabric Model AdminDomain AdminDomain Contained Domain Fabriic System Device MemberOf LogicalPortGrou p PortType= N Hosted HostedAcces spoint MemberOf C DeviceSAP Implementation Hosted ConnectivityCollecti on ProtocolEndpoint ProtocolType="Fibr echannel" MemberOf Active Connection ProtocolEndpoint ProtocolType="Fibr echannel" Switch (FC) DeviceSAP Implementation PortType= F HostedAccessPoint System Device ComputerSystem Dedicated="Switch" Current Fabric Model showing a Host and Switch Note Connectivity collects PEs AdminDomain represents the Fabric and SAN (A System)

18 FCoE Additions EthernetPort DeviceSAP Implementation C LANEndpoint LANEndpoint Switch (Ethernet) DeviceSAP Implementation EthernetPort System Device ComputerSystem Dedicated="Ethernet Switch" HostedAcces spoint Hosted Host ConnectivityCollecti on MemberOf HostedAccessPoint AdminDomain Mirror image of FC Fabric Ethernet Switch Dedicated = Ethernet Switch Host Connectivity collects LANEndpoints AdminDomain represents the Ethernet Cloud Avoiding Ethernet Topology Work Items Ethernet Switch Durable Name Cloud Durable Name

19 All together AdminDomain SAN Fabriic AdminDomain Contained Domain DeviceSAP Implementation ProtocolEndpoint ProtocolType="Fibre Channel" PortType= F PortType= F System Device MemberOf LogicalPortGroup FC Node PortType= N PortDiscriminator= PortType= N FCoE PortType= N HostedAccess Point Hosted MemberOf DeviceSAP Implementation Hosted Connectivity ProtocolEndpoint ProtocolType="Fibre Channel" MemberOf Active Connection ProtocolEndpoint ProtocolType="Fibre Channel" DeviceSAP Implementation PortType= F PortDiscriminatorr= Internal HostedAccessPoint PortType= F PortType= F System PortType= F Device System Device ComputerSystem Dedicated="FC Switch" Hosted Dependency Switch (FC) Hosted Dependency ComputerSystem Dedicated="" Flavor= Physical HostedDependency EthernetPort DeviceSAP Implementation LANEndpoint LANEndpoint DeviceSAP Implementation EthernetPort System Device ComputerSystem Dedicated="Ethernet Switch" CNA HostedAccess Point Host Connectivity MemberOf HostedAccessPoint Switch (Ethernet) Hosted AdminDomain HostedDependency relates FC to Ethernet Probably need to show binding (FCoE) relationship between PEs Partitioning Model connects the two systems (physical system not shown in this diagram) Many to Many relationship between the Ethernet Switch EthernetPort and the FC Switch

20 What is missing VLANs ACLs 20

21 DMTF Diag Profiles

22 Ethernet NIC Define a common industry standard diagnostics interface for clients to Discover and execute diagnostic tests Configure and control diagnostic test execution Monitor diagnostic test progress View and manage diagnostic test execution results FC HBA (DSP1104) Ethernet NIC (DSP1006) 22

23 ManagedElement is PortController EthernetPort Diagnose NIC problems Pre-boot vs online tests Subcomponent tests 23

24 SVPC Virtual Switch

25 Profiles almost done DSP 1097 Virtual Ethernet Switch Profile Specializes the autonomous Virtual System Profile. This profile defines the minimum top-level object model needed to define a virtualization system s internal Ethernet switch. DSP 1050 Ethernet Port Resource Virtualization Profile Specializes the abstract Resource Allocation Profile and the Allocation Capabilities Profile to specify the allocation and management of a host computers Ethernet network access, in support of virtual computer systems ability to access external and internal network. 25

26 But there is more IEEE Port Profile Work VEBs Virtual Ethernet Bridge VEPAs Virtual Ethernet Port Aggregator 26

27 Questions?

Cisco MDS 9000 Family CIM Server Support

Cisco MDS 9000 Family CIM Server Support CHAPTER 2 SMI-S defines a number of profiles that specify the managed objects used to control and monitor elements of a SAN. The Cisco MDS 9000 Family CIM server supports the standard profiles listed in

More information

FC-BB-6: New FCoE Functionality David Peterson Brocade Communications, Inc.

FC-BB-6: New FCoE Functionality David Peterson Brocade Communications, Inc. FC-BB-6: New FCoE Functionality David Peterson Brocade Communications, Inc. FC-BB-6 Project proposal scope Support for VN_Port to VN_Port virtual links Investigate improvements in support for high BER

More information

Design and Implementations of FCoE for the DataCenter. Mike Frase, Cisco Systems

Design and Implementations of FCoE for the DataCenter. Mike Frase, Cisco Systems Design and Implementations of FCoE for the DataCenter Mike Frase, Cisco Systems SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA unless otherwise noted. Member companies

More information

Controlling FCF. Lossless Ethernet network

Controlling FCF. Lossless Ethernet network 1 Distributed FCF Subclause Restructuring Add section 4.2.5.4 4.2.5.4 FC-BB_E to reference model Figure 1 shows the to reference model. FCoE frames originated by a are transported over the Lossless Ethernet

More information

Common Information Modeling for Advanced Virtual Ethernet Switches

Common Information Modeling for Advanced Virtual Ethernet Switches Common Information Modeling for Advanced Virtual Switches John Parchem - Partner Architect, Microsoft Corporation Vice-Chair, SVPC Virtual Networking, DMTF Hemal V. Shah - Associate Technical Director,

More information

Open-FCoE Software Initiator

Open-FCoE Software Initiator Open-FCoE Software Initiator Chelsio Communications, Inc. http://www.chelsio.com 1 P age Copyright 2009 Chelsio Communications, Inc. All rights reserved. 370 San Aleso Ave, Suite 100, Sunnyvale, CA 94085

More information

FCoE Cookbook for HP Virtual Connect

FCoE Cookbook for HP Virtual Connect Technical whitepaper FCoE Cookbook for HP Virtual Connect Version 4.45 Firmware Enhancements August 2015 Table of contents Change History 6 Purpose 7 Overview 7 Requirements and support 7 Supported Designs

More information

Course Documentation: Printable course material This material is copyrighted and is for the exclusive use of the student only

Course Documentation: Printable course material This material is copyrighted and is for the exclusive use of the student only Title: CompTIA Storage+ Powered by SNIA Course Length: 5 days Monday - Friday 9AM 5PM (MTN) Course Instructional Method: Interactive Lecture Lab Exam Study Sessions Course Documentation: Printable course

More information

FCoE Initialization Protocol (FIP)

FCoE Initialization Protocol (FIP) Revision 1009 1 Revision 1009 2 Footnote 1: FC_ID is also known as a 24-bit Fibre Channel address. Revision 1009 3 In a native Fibre Channel environment, a node port is directly connected to a fabric port

More information

Title: CompTIA Storage+ Powered by SNIA

Title: CompTIA Storage+ Powered by SNIA 1 Title: CompTIA Storage+ Powered by SNIA Course Length: 4.5 Days Course Instructional Method: Interactive Lecture Animations, Lab Exam Study Sessions Course Documentation DVD containing: o Printable and

More information

S S SNIA Storage Networking Foundations

S S SNIA Storage Networking Foundations S10-110 Number: S10-110 Passing Score: 800 Time Limit: 120 min S10-110 SNIA Storage Networking Foundations Exam A QUESTION 1 What are two NAS file access protocols? (Choose two.) A. SMB B. iscsi C. NFS

More information

DCNX5K: Configuring Cisco Nexus 5000 Switches

DCNX5K: Configuring Cisco Nexus 5000 Switches Course Outline Module 1: Cisco Nexus 5000 Series Switch Product Overview Lesson 1: Introducing the Cisco Nexus 5000 Series Switches Topic 1: Cisco Nexus 5000 Series Switch Product Overview Topic 2: Cisco

More information

Fibre Channel over Ethernet (FCoE)

Fibre Channel over Ethernet (FCoE) John L Hufferd, Hufferd Enterprises Author: John L Hufferd, Hufferd Enterprises SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA unless otherwise noted. Member companies

More information

PRIMERGY BX900/BX400 Blade Server Systems

PRIMERGY BX900/BX400 Blade Server Systems Installation Guide PRIMERGY BX900/BX400 Blade Server Systems Fujitsu Converged Network Adapter (CNA) for Blade Systems 1.0 PRIMERGY CNA Mezzanine Card 10Gbit/s 2-port (MC-CNA102E) for BX9xx Server Blades

More information

SwitchX Virtual Protocol Interconnect (VPI) Switch Architecture

SwitchX Virtual Protocol Interconnect (VPI) Switch Architecture SwitchX Virtual Protocol Interconnect (VPI) Switch Architecture 2012 MELLANOX TECHNOLOGIES 1 SwitchX - Virtual Protocol Interconnect Solutions Server / Compute Switch / Gateway Virtual Protocol Interconnect

More information

CompTIA Storage+ Powered by SNIA

CompTIA Storage+ Powered by SNIA CompTIA Storage+ Powered by SNIA http://www.snia.org/education/courses/training_tc Course Length: 4 1/2 days 9AM 5PM (Monday-Thursday) local time 9AM 2PM (Friday) local time Course Fee: $2,790 USD Register:

More information

Question No : 3 Which is the maximum number of active zone sets on Cisco MDS 9500 Series Fibre Channel Switches?

Question No : 3 Which is the maximum number of active zone sets on Cisco MDS 9500 Series Fibre Channel Switches? Volume: 182 Questions Question No : 1 A network architecture team is looking for a technology on Cisco Nexus switches that significantly simplifies extending Layer 2 applications across distributed data

More information

Deployment Guide: Network Convergence with Emulex OneConnect FCoE CNA and Windows Server Platform

Deployment Guide: Network Convergence with Emulex OneConnect FCoE CNA and Windows Server Platform W h i t e p a p e r Deployment Guide: Network Convergence with Emulex OneConnect FCoE CNA and Windows Server Platform How to Deploy Converged Networking with a Windows Server Platform Using Emulex OneConnect

More information

HP StorageWorks Fabric OS 6.1.2_cee1 release notes

HP StorageWorks Fabric OS 6.1.2_cee1 release notes HP StorageWorks Fabric OS 6.1.2_cee1 release notes Part number: 5697-0045 First edition: June 2009 Legal and notice information Copyright 2009 Hewlett-Packard Development Company, L.P. Copyright 2009 Brocade

More information

ECE Enterprise Storage Architecture. Fall 2016

ECE Enterprise Storage Architecture. Fall 2016 ECE590-03 Enterprise Storage Architecture Fall 2016 Storage Area Network (SAN) Tyler Bletsch Duke University Adapted from the course Information Storage and Management v2 (module 5-6), published by EMC

More information

DMTF Management Initiatives for Academics

DMTF Management Initiatives for Academics DMTF Management Initiatives for Academics Jeff Hilland VP of Technology, DMTF 1 Agenda DMTF Management Initiatives SMASH DASH CDM Additional DMTF Standardization Protocols, Profiles, Generic Operations,

More information

UCS Engineering Details for the SAN Administrator

UCS Engineering Details for the SAN Administrator UCS Engineering Details for the SAN Administrator Craig Ashapa 2 First things first: debunking a myth Today (June 2012 UCS 2.02m) there is no FCoE northbound of UCS unless you really really really want

More information

The confusion arising from Converged Multihop Topologies as to the roles and capabilities of FCFs, FCoE-FC Gateways, and FCoE Transit Switches

The confusion arising from Converged Multihop Topologies as to the roles and capabilities of FCFs, FCoE-FC Gateways, and FCoE Transit Switches The confusion arising from Converged Multihop Topologies as to the roles and capabilities of s, FCoE-FC Gateways, and FCoE Transit Switches Simon J Gordon, Juniper Networks Author: Simon J Gordon, Juniper

More information

VIRTUALIZING SERVER CONNECTIVITY IN THE CLOUD

VIRTUALIZING SERVER CONNECTIVITY IN THE CLOUD VIRTUALIZING SERVER CONNECTIVITY IN THE CLOUD Truls Myklebust Director, Product Management Brocade Communications 2011 Brocade Communciations - All Rights Reserved 13 October 2011 THE ENTERPRISE IS GOING

More information

Network Port Profiles Based Provisioning and Deployment Models for Virtual Networking

Network Port Profiles Based Provisioning and Deployment Models for Virtual Networking Port Profiles Based Provisioning and Deployment Models for Virtual ing Hemal V. Shah Infrastructure and ing Group Broadcom Corporation Irvine, California, USA hemal@broadcom.com John Parchem Microsoft

More information

Fibre Channel vs. iscsi. January 31, 2018

Fibre Channel vs. iscsi. January 31, 2018 Fibre Channel vs. iscsi January 31, 2018 Today s Presenters Fred Knight NetApp John Kim SNIA ESF Chair Mellanox Alex McDonald SNIA ESF Vice Chair NetApp 2 SNIA-At-A-Glance 3 SNIA Legal Notice The material

More information

Industry Standards for the Exponential Growth of Data Center Bandwidth and Management. Craig W. Carlson

Industry Standards for the Exponential Growth of Data Center Bandwidth and Management. Craig W. Carlson Industry Standards for the Exponential Growth of Data Center Bandwidth and Management Craig W. Carlson 2 Or Finding the Fat Pipe through standards Creative Commons, Flikr User davepaker Overview Part of

More information

Expert Insights: Expanding the Data Center with FCoE

Expert Insights: Expanding the Data Center with FCoE Expert Insights: Expanding the Data Center with FCoE PRESENTATION TITLE GOES HERE Joe Kastura, Joe Gervais, Jason Blosil August 20, 2014 Today s Presenters Jason Blosil, SNIA ESF Chair Product Marketing

More information

Service Oriented Virtual DC Design

Service Oriented Virtual DC Design Dubrovnik, Croatia, South East Europe 20-22 May, 2013 Service Oriented Virtual DC Design Višnja Milovanović Consulting Systems Engineer Data Center & Virtualization 2011 2012 Cisco and/or its affiliates.

More information

Vendor: Cisco. Exam Code: Exam Name: Introducing Cisco Data Center Technologies. Version: Demo

Vendor: Cisco. Exam Code: Exam Name: Introducing Cisco Data Center Technologies. Version: Demo Vendor: Cisco Exam Code: 640-916 Exam Name: Introducing Cisco Data Center Technologies Version: Demo DEMO QUESTION 1 Which two Cisco Nexus 2000-Series Fabric Extenders support connections to both Cisco

More information

www.passforsure.co 642-999 www.passforsure.co QUESTION: 1 When upgrading a standalone Cisco UCS C-Series server, which method is correct? A. direct upgrade on all components B. Cisco Hardware Upgrade Utility

More information

Fibre Channel Zoning

Fibre Channel Zoning Information About, page 1 Support for in Cisco UCS Manager, page 2 Guidelines and recommendations for Cisco UCS Manager-Based, page 4 Configuring, page 4 Creating a VSAN for, page 6 Creating a New Fibre

More information

Virtual Networking Management White Paper

Virtual Networking Management White Paper Version 1.0.0a Status: Informational Publication Date: February 18, 2011 DSP2025 wgv 0.8.3 Information for work in progress version: IMPORTANT: This specification is not a standard. It does not necessarily

More information

Cisco CCIE Data Center Written (Beta) Download Full Version :

Cisco CCIE Data Center Written (Beta) Download Full Version : Cisco 351-080 CCIE Data Center Written (Beta) Download Full Version : https://killexams.com/pass4sure/exam-detail/351-080 Answer: A QUESTION: 105 What is the function of the WWPN pool? A. to assign WWPNs

More information

Comparing Server I/O Consolidation Solutions: iscsi, InfiniBand and FCoE. Gilles Chekroun Errol Roberts

Comparing Server I/O Consolidation Solutions: iscsi, InfiniBand and FCoE. Gilles Chekroun Errol Roberts Comparing Server I/O Consolidation Solutions: iscsi, InfiniBand and FCoE Gilles Chekroun Errol Roberts SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies

More information

Independent Submission Request for Comments: 6847 Category: Informational. Huawei January 2013

Independent Submission Request for Comments: 6847 Category: Informational. Huawei January 2013 Independent Submission Request for Comments: 6847 Category: Informational ISSN: 2070-1721 D. Melman T. Mizrahi Marvell D. Eastlake 3rd Huawei January 2013 Fibre Channel over Ethernet (FCoE) over Transparent

More information

VN2VN: A new framework for L2 DAS Prafulla Deuskar Mark Wunderlich Intel

VN2VN: A new framework for L2 DAS Prafulla Deuskar Mark Wunderlich Intel VN2VN: A new framework for L2 DAS Prafulla Deuskar Mark Wunderlich Intel L2 DAS Vision Provide a simple extensible L2 block storage network From host SCSI layer devices discovered as Direct Attached Storage

More information

CloudEngine 8800&7800&6800 Series Switches. FCoE and DCB Technology White Paper. Issue 03 Date HUAWEI TECHNOLOGIES CO., LTD.

CloudEngine 8800&7800&6800 Series Switches. FCoE and DCB Technology White Paper. Issue 03 Date HUAWEI TECHNOLOGIES CO., LTD. FCoE and DCB Technology White Paper Issue 03 Date 2016-01-15 HUAWEI TECHNOLOGIES CO., LTD. 2016. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means

More information

UM DIA NA VIDA DE UM PACOTE CEE

UM DIA NA VIDA DE UM PACOTE CEE UM DIA NA VIDA DE UM PACOTE CEE Marcelo M. Molinari System Engineer - Brazil May 2010 CEE (Converged Enhanced Ethernet) Standards Making 10GbE Lossless and Spanning-Tree Free 2010 Brocade Communications

More information

Overview of Cisco Unified Computing System

Overview of Cisco Unified Computing System Overview of Cisco Unified Computing System This chapter includes the following sections: About Cisco Unified Computing System, page 1 Unified Fabric, page 2 Server Architecture and Connectivity, page 4

More information

SAN Virtuosity Fibre Channel over Ethernet

SAN Virtuosity Fibre Channel over Ethernet SAN VIRTUOSITY Series WHITE PAPER SAN Virtuosity Fibre Channel over Ethernet Subscribe to the SAN Virtuosity Series at www.sanvirtuosity.com Table of Contents Introduction...1 VMware and the Next Generation

More information

Dell DCPPE-200. Dell PowerEdge Professional. Download Full version :

Dell DCPPE-200. Dell PowerEdge Professional. Download Full version : Dell DCPPE-200 Dell PowerEdge Professional Download Full version : https://killexams.com/pass4sure/exam-detail/dcppe-200 untagged VLAN 1 and tagged VLANs 10, 20, and 50. The engineer has port 1 configured

More information

NC-SI 1.2 Topics- Work-In- Progress. Version 0.10 September 13, 2017

NC-SI 1.2 Topics- Work-In- Progress. Version 0.10 September 13, 2017 NC-SI 1.2 Topics- Work-In- Progress Version 0.10 September 13, 2017 Disclaimer The information in this presentation represents a snapshot of work in progress within the DMTF. This information is subject

More information

Contents. FCoE commands 0

Contents. FCoE commands 0 Contents FCoE commands 0 FCoE mode commands 0 display fcoe-mode 0 fcoe-mode 0 VFC interface commands 2 bandwidth 2 bind interface 2 default 3 description 4 display interface vfc 5 fc mode 8 interface vfc

More information

Evolution with End-to-End Data Center Virtualization

Evolution with End-to-End Data Center Virtualization Evolution with End-to-End Data Center Virtualization Yves Louis DC Virtualisation Technical Solution Architect Agenda Data Center Virtualization Overview Front-End Data Center Virtualization Core Layer

More information

ETHERNET ENHANCEMENTS FOR STORAGE. Sunil Ahluwalia, Intel Corporation Errol Roberts, Cisco Systems Inc.

ETHERNET ENHANCEMENTS FOR STORAGE. Sunil Ahluwalia, Intel Corporation Errol Roberts, Cisco Systems Inc. ETHERNET ENHANCEMENTS FOR STORAGE Sunil Ahluwalia, Intel Corporation Errol Roberts, Cisco Systems Inc. SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies

More information

UCS Direct Attached Storage and FC Zoning Configuration Example

UCS Direct Attached Storage and FC Zoning Configuration Example UCS Direct Attached Storage and FC Zoning Configuration Example Document ID: 116082 May 23, 2013 Contents Introduction Prerequisites Requirements Components Used Conventions Background Information UCS

More information

STORAGE 101. LAN to SAN in 90min

STORAGE 101. LAN to SAN in 90min STORAGE 101 LAN to SAN in 90min 1 Agenda Basics Open Systems Architecture Basics I/O Subsystem Block vs. File Storage SCSI Basics SAN Primer for LAN Professionals Basic Concepts LAN vs. SAN Comparisons

More information

Product Overview >> Cisco R Series Racks: Make Your Infrastructure Highly Secure. Has an innovative design to deliver exceptional power, cooling, and cable management, as well as strength and stability

More information

CCIE Data Center Storage Networking. Fibre Channel Switching

CCIE Data Center Storage Networking. Fibre Channel Switching CCIE Data Center Storage Networking Fibre Channel Switching What is Fibre Channel? From a high level, replaces SCSI disk cable with a network From this To this What is Fibre Channel? Protocol stack primarily

More information

FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch

FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch Document ID: 117280 Contributed by Padmanabhan, Cisco TAC Engineer. Mar 25, 2014 Contents Introduction Prerequisites Requirements

More information

Boot and Network Configuration Deployment using Server Template with Dell EMC OpenManage Essentials (OME)

Boot and Network Configuration Deployment using Server Template with Dell EMC OpenManage Essentials (OME) Boot and Network Configuration Deployment using Server Template with Dell EMC OpenManage Essentials (OME) Dell EMC Engineering February 2018 A Dell EMC Technical White Paper Revisions Date August 2017

More information

CCIE Data Center Lab Exam Version 1.0

CCIE Data Center Lab Exam Version 1.0 CCIE Data Center Lab Exam Version 1.0 CCIE Data Center Sky rocketing Popularity should not come as any surprise As per Cisco Global Cloud index, published in 2012, gave prediction that by 2016 nearly two

More information

FIBRE CHANNEL OVER ETHERNET

FIBRE CHANNEL OVER ETHERNET FIBRE CHANNEL OVER ETHERNET A Review of FCoE Today Abstract Fibre Channel over Ethernet (FcoE) is a storage networking option, based on industry standards. This white paper provides an overview of FCoE,

More information

Storage Protocol Offload for Virtualized Environments Session 301-F

Storage Protocol Offload for Virtualized Environments Session 301-F Storage Protocol Offload for Virtualized Environments Session 301-F Dennis Martin, President August 2016 1 Agenda About Demartek Offloads I/O Virtualization Concepts RDMA Concepts Overlay Networks and

More information

Server-to-network edge technologies: converged networks and virtual I/O

Server-to-network edge technologies: converged networks and virtual I/O Server-to-network edge technologies: converged networks and virtual I/O Technology brief Table of contents Executive Summary... 2 What is the server-to-network edge?... 3 Physical infrastructure challenges

More information

Big Data Processing Technologies. Chentao Wu Associate Professor Dept. of Computer Science and Engineering

Big Data Processing Technologies. Chentao Wu Associate Professor Dept. of Computer Science and Engineering Big Data Processing Technologies Chentao Wu Associate Professor Dept. of Computer Science and Engineering wuct@cs.sjtu.edu.cn Schedule (1) Storage system part (first eight weeks) lec1: Introduction on

More information

Configuring Fibre Channel Interfaces

Configuring Fibre Channel Interfaces This chapter contains the following sections:, page 1 Information About Fibre Channel Interfaces Licensing Requirements for Fibre Channel On Cisco Nexus 3000 Series switches, Fibre Channel capability is

More information

CCIE Data Center Storage Networking. Fibre Channel Switching Configuration. Nexus 5500UP FC Initialization Allocate interfaces as type FC

CCIE Data Center Storage Networking. Fibre Channel Switching Configuration. Nexus 5500UP FC Initialization Allocate interfaces as type FC CCIE Data Center Storage Networking Fibre Channel Switching Configuration Nexus 5500UP FC Initialization Allocate interfaces as type FC slot 1 port 25 32 type fc FC must start at top of module and count

More information

Direct Attached Storage

Direct Attached Storage , page 1 Fibre Channel Switching Mode, page 1 Configuring Fibre Channel Switching Mode, page 2 Creating a Storage VSAN, page 3 Creating a VSAN for Fibre Channel Zoning, page 4 Configuring a Fibre Channel

More information

SNIA Discussion on iscsi, FCIP, and IFCP Page 1 of 7. IP storage: A review of iscsi, FCIP, ifcp

SNIA Discussion on iscsi, FCIP, and IFCP Page 1 of 7. IP storage: A review of iscsi, FCIP, ifcp SNIA Discussion on iscsi, FCIP, and IFCP Page 1 of 7 IP storage: A review of iscsi, FCIP, ifcp SNIA IP Storage Forum With the advent of new IP storage products and transport protocol standards iscsi, FCIP,

More information

Managing Network Adapters

Managing Network Adapters Managing Network Adapters This chapter includes the following sections: Overview of the Cisco UCS C-Series Network Adapters, page 1 Viewing Network Adapter Properties, page 3 Configuring Network Adapter

More information

FCIA Fibre Channel: Live Long and Prosper

FCIA Fibre Channel: Live Long and Prosper Data Center Networking FCIA Fibre Channel: Live Long and Prosper Mark Jones President Fibre Channel Industry Association Director of Technical Marketing - Emulex Agenda How the FC Industry Innovates The

More information

Advanced FCoE: Extension of Fibre Channel over Ethernet

Advanced FCoE: Extension of Fibre Channel over Ethernet XX 事業本部 YY 殿 2011 3rd Workshop on Data Center Converged and Virtual Ethernet Switching DC CaVES 2011 Advanced : Extension of Fibre Channel over Ethernet September 9, 2011 Satoshi Kamiya, Kiyohisa Ichino,

More information

Low latency and high throughput storage access

Low latency and high throughput storage access Low latency and high throughput storage access Journey from SCSI to NVMe in FC fabrics Raj Lalsangi Santa Clara, CA 1 Protocol neutral architecture principles Reduce / avoid interrupts Avoid context switches

More information

A. Both Node A and Node B will remain on line and all disk shelves will remain online.

A. Both Node A and Node B will remain on line and all disk shelves will remain online. Volume: 75 Questions Question No: 1 On a FAS8040, which port is used for FCoE connections? A. e0m B. e0p C. 0a D. e0h Answer: D Question No: 2 Click the Exhibit button. Referring to the diagram shown in

More information

The Confusion Arising from Converged Multi Hop FCoE Topologies

The Confusion Arising from Converged Multi Hop FCoE Topologies Author: Simon Gordon, Juniper Networks The Confusion Arising from Converged Multi Hop FCoE Topologies Simon Gordon, Juniper Networks SNIA Legal Notice The material contained in this tutorial is copyrighted

More information

January Network Advisor. Features Support Matrix. Supporting Brocade Network Advisor

January Network Advisor. Features Support Matrix. Supporting Brocade Network Advisor 29 January 2016 Network Advisor Features Support Matrix Supporting Brocade Network Advisor 12.4.3 2016, Brocade Communications Systems, Inc. All Rights Reserved. Brocade, Brocade Assurance, the B-wing

More information

Unified Storage Networking. Dennis Martin President, Demartek

Unified Storage Networking. Dennis Martin President, Demartek Unified Storage Networking Dennis Martin President, Demartek Demartek Company Overview Industry analysis with on-site test lab Most projects involve use of the lab Lab includes servers, networking and

More information

BraindumpsIT. BraindumpsIT - IT Certification Company provides Braindumps pdf!

BraindumpsIT.   BraindumpsIT - IT Certification Company provides Braindumps pdf! BraindumpsIT http://www.braindumpsit.com BraindumpsIT - IT Certification Company provides Braindumps pdf! Exam : 200-150 Title : Introducing Cisco Data Center Networking Vendor : Cisco Version : DEMO Get

More information

Networking in Virtual Infrastructure and Future Internet. NCHC Jen-Wei Hu

Networking in Virtual Infrastructure and Future Internet. NCHC Jen-Wei Hu Networking in Virtual Infrastructure and Future Internet NCHC Jen-Wei Hu Overview Virtualization Networking in Virtualization Future Internet 2 Hardware virtualization Hardware virtualization techniques

More information

Redefining Storage Economics. Ethernet SAN Comparison of FC (and FCoE), iscsi, and AoE Robert Przykucki, Director of Product Management

Redefining Storage Economics. Ethernet SAN Comparison of FC (and FCoE), iscsi, and AoE Robert Przykucki, Director of Product Management Ethernet SAN Comparison of FC (and FCoE), iscsi, and AoE Robert Przykucki, Director of Product Management November 2010 Unique Market Window: Ethernet SAN IT Budget 40% Unsustainable storage costs in uncertain

More information

HP Storage Summit 2015

HP Storage Summit 2015 HP Storage Summit 2015 Transform Now. Network Innovation to Maximize Storage Evolution Marty Lans Senior Director, Storage and Data Center Network Engineering & Development The networks role in the evolution

More information

Dell Networking S5000: Deployment of a Converged Infrastructure with FCoE. Deployment/Configuration Guide

Dell Networking S5000: Deployment of a Converged Infrastructure with FCoE. Deployment/Configuration Guide Dell Networking S5000: Deployment of a Converged Infrastructure with FCoE Dell Technical Marketing Data Center Networking June 2013 This document is for informational purposes only and may contain typographical

More information

EqualLogic iscsi SAN Concepts for the Experienced Fibre Channel Storage Professional A Dell Technical Whitepaper

EqualLogic iscsi SAN Concepts for the Experienced Fibre Channel Storage Professional A Dell Technical Whitepaper Dell EqualLogic Best Practices Series EqualLogic iscsi SAN Concepts for the Experienced Fibre Channel Storage Professional A Dell Technical Whitepaper Storage Infrastructure and Solutions Engineering Dell

More information

Configuring FCoE NPV. Information About FCoE NPV. This chapter contains the following sections:

Configuring FCoE NPV. Information About FCoE NPV. This chapter contains the following sections: This chapter contains the following sections: Information About FCoE NPV, page 1 FCoE NPV Model, page 3 Mapping Requirements, page 4 Port Requirements, page 5 NPV Features, page 5 vpc Topologies, page

More information

Contents. Configuring LLDP 2

Contents. Configuring LLDP 2 Contents Configuring LLDP 2 Overview 2 Basic concepts 2 Working mechanism 8 Protocols and standards 9 LLDP configuration task list 9 Performing basic LLDP configurations 10 Enabling LLDP 10 Configuring

More information

Emulex Drivers Version 10.6 for Windows. Quick Installation Manual

Emulex Drivers Version 10.6 for Windows. Quick Installation Manual Emulex Drivers Version 10.6 for Windows Quick Installation Manual Connect Monitor Manage 2 Copyright 2003-2015 Emulex. All rights reserved worldwide. No part of this document may be reproduced by any means

More information

Cisco Exam Questions & Answers

Cisco Exam Questions & Answers Cisco 642-997 Exam Questions & Answers Number: 642-997 Passing Score: 900 Time Limit: 120 min File Version: 36.4 http://www.gratisexam.com/ Cisco 642-997 Exam Questions & Answers Exam Name: Implementing

More information

CCIE Data Center Written Exam ( ) version 1.0

CCIE Data Center Written Exam ( ) version 1.0 CCIE Data Center Written Exam (350-080) version 1.0 Exam Description: The Cisco CCIE Data Center Written Exam (350-080) version 1.0 is a 2-hour test with 80 110 questions that will validate that a data

More information

Virtual Networks: For Storage and Data

Virtual Networks: For Storage and Data Virtual Networks: For Storage and Data or Untangling the Virtual Server Spaghetti Pile Howard Marks Chief Scientist hmarks@deepstorage.net Our Agenda Today s Virtual Server I/O problem Why Bandwidth alone

More information

2014 LENOVO INTERNAL. ALL RIGHTS RESERVED.

2014 LENOVO INTERNAL. ALL RIGHTS RESERVED. 2014 LENOVO INTERNAL. ALL RIGHTS RESERVED. Connectivity Categories and Selection Considerations NIC HBA CNA Primary Purpose Basic Ethernet Connectivity Connection to SAN/DAS Converged Network and SAN connectivity

More information

BMC Capacity Optimization Extended Edition AIX Enhancements

BMC Capacity Optimization Extended Edition AIX Enhancements BMC Capacity Optimization Extended Edition 9.5.1 AIX Enhancements Support for AIX Active Memory Expansion (AME) mode Metrics displayed in BCO AIX PowerVM view for CPU and Memory Allocation Frame name,

More information

PCI Express x8 Quad Port 10Gigabit Server Adapter (Intel XL710 Based)

PCI Express x8 Quad Port 10Gigabit Server Adapter (Intel XL710 Based) NIC-PCIE-4SFP+-PLU PCI Express x8 Quad Port 10Gigabit Server Adapter (Intel XL710 Based) Key Features Quad-port 10 GbE adapters PCI Express* (PCIe) 3.0, x8 Exceptional Low Power Adapters Network Virtualization

More information

SAN Configuration Guide

SAN Configuration Guide ONTAP 9 SAN Configuration Guide November 2017 215-11168_G0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Considerations for iscsi configurations... 5 Ways to configure iscsi

More information

Elxflash and LpCfg Utilities Release Notes

Elxflash and LpCfg Utilities Release Notes Elxflash and LpCfg Utilities Release Notes Versions: FreeBSD Elxflash Offline, Version 10.4.255.16 Linux ElxflashOffline Kit, Version 10.4.255.25 Linux ElxflashOffline for NIC-only Kit, Version 10.4.255.25

More information

SRM: Can You Get What You Want? John Webster, Evaluator Group.

SRM: Can You Get What You Want? John Webster, Evaluator Group. SRM: Can You Get What You Want? John Webster, Evaluator Group. SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies and individual members may use this

More information

HP FlexFabric 5700 Switch Series

HP FlexFabric 5700 Switch Series HP FlexFabric 5700 Switch Series FAQ Copyright 2015 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and

More information

45 10.C. 1 The switch should have The switch should have G SFP+ Ports from Day1, populated with all

45 10.C. 1 The switch should have The switch should have G SFP+ Ports from Day1, populated with all Addendum / Corrigendum Dated 29/09/2017 Tender Ref No. - 236/387/DCCS/2010/IREDA/1 Dated: 22/09/2017 Name of Project - Supply Installation and Support Services of Data centers S. No. Document Reference

More information

NETWORK ARCHITECTURES AND CONVERGED CLOUD COMPUTING. Wim van Laarhoven September 2010

NETWORK ARCHITECTURES AND CONVERGED CLOUD COMPUTING. Wim van Laarhoven September 2010 NETWORK ARCHITECTURES AND CONVERGED NETWORKS FABRICS FOR CLOUD COMPUTING Wim van Laarhoven Wim.vanlaarhoven@brocade.com +31653794500 16 September 2010 Legal Disclaimer All or some of the products detailed

More information

Use Cases for iscsi and FCoE: Where Each Makes Sense

Use Cases for iscsi and FCoE: Where Each Makes Sense Use Cases for iscsi and FCoE: Where Each Makes Sense PRESENTATION TITLE GOES HERE February 18, 2014 Today s Presenters David Fair, SNIA ESF Business Development Chair - Intel Sameh Boujelbene - Director,

More information

vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide

vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide Technical white paper vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide Updated: 4/30/2015 Hongjun Ma, HP DCA Table of contents Introduction...

More information

Contents. FCoE commands 1

Contents. FCoE commands 1 Contents FCoE commands 1 FCoE mode commands 1 display fcoe-mode 1 fcoe-mode 1 VFC interface commands 3 bandwidth 3 bind interface 3 default 5 description 5 display interface vfc 6 fc mode 9 interface vfc

More information

Overview. About the Common Information Model. Send documentation comments to CHAPTER

Overview. About the Common Information Model. Send documentation comments to CHAPTER CHAPTER 1 The Cisco MDS 9000 Family of multilayer directors and fabric switches provide an industry standard application programming interface (API) using the Storage Management Initiative Specification

More information

Huawei MZ510 NIC V100R001. White Paper. Issue 09 Date HUAWEI TECHNOLOGIES CO., LTD.

Huawei MZ510 NIC V100R001. White Paper. Issue 09 Date HUAWEI TECHNOLOGIES CO., LTD. V100R001 Issue 09 Date 2016-11-21 HUAWEI TECHNOLOGIES CO., LTD. 2016. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent

More information

Vendor: EMC. Exam Code: E Exam Name: Cloud Infrastructure and Services Exam. Version: Demo

Vendor: EMC. Exam Code: E Exam Name: Cloud Infrastructure and Services Exam. Version: Demo Vendor: EMC Exam Code: E20-002 Exam Name: Cloud Infrastructure and Services Exam Version: Demo QUESTION NO: 1 In which Cloud deployment model would an organization see operational expenditures grow in

More information

Unified Storage and FCoE

Unified Storage and FCoE Unified Storage and FCoE Mike McNamara, NetApp February 24, 2011 Santa Clara, CA USA February 2011 1 Agenda Market Dynamics Why Unified Ethernet Storage Customer Success Stories Santa Clara, CA USA February

More information

"Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary

Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary Description Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary v6.0 is a five-day instructor-led course that is designed to help students prepare for the Cisco CCNP Data Center

More information

ETHERNET ENHANCEMENTS FOR STORAGE. Sunil Ahluwalia, Intel Corporation

ETHERNET ENHANCEMENTS FOR STORAGE. Sunil Ahluwalia, Intel Corporation ETHERNET ENHANCEMENTS FOR STORAGE Sunil Ahluwalia, Intel Corporation SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies and individual members may use

More information

Transition to the Data Center Bridging Era with EqualLogic PS Series Storage Solutions A Dell Technical Whitepaper

Transition to the Data Center Bridging Era with EqualLogic PS Series Storage Solutions A Dell Technical Whitepaper Dell EqualLogic Best Practices Series Transition to the Data Center Bridging Era with EqualLogic PS Series Storage Solutions A Dell Technical Whitepaper Storage Infrastructure and Solutions Engineering

More information