1 IP Gateway Card Getting Started Model No. KX-TDA0480 Thank you for purchasing the Panasonic Model KX-TDA0480, IP Gateway Card. Please read this manual before installing the IP Gateway Card and save this manual for future reference.

2 Table of Contents 1 Overview Example Network Diagramme Network Devices and Numbering Plan Numbering Plan Example Physical Installation Installation Names and Locations DIP Switch Settings Installing the IP Gateway Card to the Hybrid IP-PBX Indication Light (LED) Cable Connection RS-232C Cable Connection Base-T Cable Connection Trunk Programming of the Hybrid IP-PBX Trunk Programming of the Hybrid IP-PBX Logical Installation (Maintenance Console Software) The Maintenance Console Software (MCS) Installing the MCS Starting MCS and Logging-in MCS Main Directory Window Serial Port Setting Changing the Password Creating New Group and Gateway Creating a New Unit Group (Office) Creating a New Gateway (IP Gateway Card) Configuring Domain Name System (DNS) Data Editing DNS Data Configuring Office Data Transferring the Data to the IP Gateway Card Synchronising Time and Date of the IP Gateway Card Optimising Performance Preventing Problems Voice Volume Transmission Delays Priority Control Recovery Delay and Jitter Buffer Internet, Intranet, and Virtual Private Networks (VPN) Getting Started

3 Section 1 Overview Panasonic Hybrid IP-PBX with KX-TDA0480, IP Gateway Card, will allow organisations to route both voice and fax communications over digital data networks. The KX-TDA0480, designed to be easily integrated into existing LAN/WAN environments, seamlessly bridges Public Switched Telephone Network (PSTN) and analogue telephone with digital data networks without interrupting or compromising ongoing data communications. Because communications do not take place over conventional telephone networks, the high cost of long distance communications is virtually eliminated. Getting Started 3

4 1.1 Example Network Diagramme 1.1 Example Network Diagramme The following diagramme illustrates a simple VoIP network connecting Hybrid IP-PBXs at 2 different locations. The IP Gateway Card converts outgoing voice or fax signals into IP data packets for transmission. On the incoming side, it reverses this process and translates the packets back into appropriate voice or fax signals. PSTN (Public Switched Telephone Network) Switching HUB Hybrid IP-PBX with IP Gateway Card Voice signals are converted into IP data packets. Firewall Router Other data packets. LAN Voice data packets. PSTN 4 Getting Started

5 1.2 Network Devices and Numbering Plan 1.2 Network Devices and Numbering Plan Once the installation of IP Gateway Cards begins, network configuration information needs to be on-hand. The following diagramme illustrates devices found in an IP network. Referring to this example, consult your network administrator to obtain necessary information to configure your own network. Local Telephone Extn. 201 ( ) G3 Fax Extn. 501 ( ) PSTN (Public Switched Telephone Network) PSTN Trunk Number: 9 PBX Office Code: 35 Gateway Unit IP: IP Trunk Number: 801 IP: Subnet Mask: Los Angels Office LAN Chicago Office Subnet Mask: PBX Office Code: 41 Gateway Unit IP: IP Trunk number: 801 PSTN Trunk Number: 9 IP: PSTN G3 Fax Extn. 601 ( ) Extn. 301 ( ) Local Telephone Getting Started 5

6 1.2 Network Devices and Numbering Plan Notes Recommended IP Networks: the IP Gateway Card's quality of performance depends on the type of network in use. For instance, transmission delays due to congestion on the network and inadequate service characteristics of Internet Service Provider (ISP) can both contribute to loss in voice communications. Manageable networks (e.g., LAN) in which static *1 IP addresses can be used provide better quality of service compared to unmanageable networks such as the Internet. Firewalls: a firewall protects the internal networks of an organisation against unauthorised penetration from outside. However, routing a VoIP network through a firewall may cause performance degradation. Check with your network administrator of the existence of firewall Numbering Plan Example This section describes the network numbering mechanism based on the previous example diagramme. Please configure your network referring to this example. IP Addressing Information IP addressing information is typically supplied by a network administrator. Consult your network administrator for specific values. Description Los Angels Office Chicago Office Gateway IP Address Route IP Address (Firewall or Router) The Gateway IP address identifies the location of each unit in the network during VoIP communications. A unique IP address must be assigned to each unit. When the IP Gateway Card is routed through a firewall, the internal IP address of firewall becomes the Gateway address to be associated with the IP Gateway Card instead of the router IP address Subnet Mask Address Each network location has a subnet mask address that helps to define which digits of an IP address are used for the network address and the host address. Each Gateway IP addresse must fall within the same subnet as that of the router shared by the units (default) (default) *1 Dynamic IP addressing (using DHCP/BOOTP) is not supported. 6 Getting Started

7 1.2 Network Devices and Numbering Plan PBX Numbering Information PBX numbering information is necessary to setup phone numbers for a VoIP network. Configure the numbers conforming to existing PBX numbering systems. Description Los Angels Office Chicago Office PBX Office Code IP Trunk Number PSTN Trunk Number Extension Number A unique number (ranging from 1 to 8 digits) assigned to identify each Hybrid IP-PBX within a network. In this example, for convenience, each PBX Office Code corresponds to the last portion of the IP address of its Gateway unit; that is, because Los Angels Office unit has the IP address of , Los Angels PBX Office Code is 35. An access number to seize an IP trunk. Any available trunk number can be assigned as an IP Trunk Number. An access number to seize a local PSTN trunk. A number assigned to each extension Dialling Examples The VoIP network allows you to access the PBX at one location from another to establish: (1) an extension call, or (2) an outside call through local PSTN as if you are calling from the same area. Calling from Los Angels to Chicago To extension 301 via IP network IP trunk no. Chicago PBX office code extension no. Dial 801. Dial 41. Dial 301. To local telephone via IP network through local PSTN IP trunk no. Chicago PBX office code Chicago PBX PSTN trunk no. phone no. Dial 801. Dial 41. Dial 9. Dial Getting Started 7

8 1.2 Network Devices and Numbering Plan Calling from Chicago to Los Angels To extension 201 via IP network IP trunk no. Los Angels PBX office code extension no. Dial 801. Dial 35. Dial 201. To local telephone via IP network through local PSTN IP trunk no. Los Angels PBX office code Los Angels PBX PSTN trunk no. phone no. Dial 801. Dial 35. Dial 9. Dial PBX Connection Information PBX connection information is created by combining IP Addressing Information and PBX Numbering Information. According to the sample below, please create your own PBX connection information. Terminal Number: The number composed of the PBX Office Code followed by the first digit from the destination number. See the example on the right. Remaining Digits: The number of digits needed to be dialled in addition to the Terminal Number to access the destination. (Setting, for example, remaining digits to 7 does not mean that the user must dial all 7 digits when making a call.) See the example on the right. PBX Office Code Los Angels extensions Terminal No. Remaining Digits First digit of the extension number Remaining digits of the extension number Signal Port Number: The TCP port number on which call control signal transmission will occur. When installing the IP Gateway Card within a firewall as in this example, voice and fax packets must routed through specified firewall ports. Consult your network administrator for specific values. Access IP Address: The IP address of each unit in the network (as the access destination). Los Angels PBX (Office Code: 35) Chicago PBX (Office Code: 41) Extensions FAX Extensions PSTN Access Extensions FAX Extensions PSTN Access Terminal Number Remaining Digits Signal Port Number 1720 (default) 1720 (default) Access IP Address Getting Started

9 Section 2 Physical Installation Getting Started 9

10 2.1 Installation 2.1 Installation Names and Locations Indication Lights LED1 IP Link Connector LED8 Serial (RS-232C) Connector DIP Switch Settings The default DIP Switch settings are as illustrated below. Confirm that the switches are in the default positions before installing the IP Gateway Card. ON OFF Dip Switch SW4 ON SW OFF Dip Switch 10 Getting Started

11 2.1 Installation Installing the IP Gateway Card to the Hybrid IP-PBX 1. Insert the card along the guide rails. Guide Rails Back Board 1 2. Holding the card as shown on the left, push the release lever in the direction of the arrow so that the card is made to engage with the connector on the back board securely Turn the screws clockwise to fix the card. screws Getting Started 11

12 2.1 Installation Indication Light (LED) LED 1 LED 2 LED 3 LED 4 LED 5 LED 6 LED 7 LED 8 LED1 Green/Red LED2 Green LED3 Red LED4 Green LED5 Green LED6 Green LED7 Green LED8 Green Channel Status Off: Power Off Green Flash: Normal (channel used) Red On: During reset Red Flash: Out of Service Online Status On: On-line mode Flash: Emergency maintenance mode Alarm Off: Normal On: Alarm Busy status Off: Not used On: At least one line is used Link status Off: Connection error On: Normal Connection Data transmission Off: No data transmitted On: Data transmitting Collision status Off: No data collision On: Data collision SIOSEL Off: CPU port used (Maintenance port not available) On: Maintenance port available 12 Getting Started

13 2.2 Cable Connection 2.2 Cable Connection RS-232C Cable Connection To initialise a newly installed IP Gateway Card using the Maintenance Console Software (see 4.2 Creating New Group and Gateway), a computer or terminal must be connected directly to the unit using an RS-232C serial (cross) cable with DB9 Female to DB9 Female connectors. 1. Turn the computer power OFF. 2. Connect the RS-232C cable to one of the PC's COM ports (e.g., COM 1) and to the Serial Port connector on the IP Gateway Card front panel. RS-232C Serial Cable (Cross cable) To COM port To IP Gateway Card RS-232C port PC Hybrid IP-PBX COM port on the PC Circuit Type (EIA) AA BA BB CA CB CC AB CF CD Signal Name FG SD (TXD) RD (RXD) RTS CTS DR (DSR) SG DCD ER (DTR) Pin No RS-232C port on the IP Gateway Card Pin No Signal Name RI RXD TXD RTS CTS DTR SG DSR DCD Circuit Type (EIA) CE BB BA CA CB CD AB CC CF Base-T Cable Connection A standard 10 Base-T cable with an RJ-45 connector is used to interconnect the IP Gateway Card with a network device. 1. Insert the RJ-45 connector into the IP Gateway Card Uplink port located on the IP Gateway Card front panel. 2. Connect the other end of the 10 Base-T cable to the remote LAN equipment. Router 10 Base-T straight cable PC Switching HUB or Hybrid IP-PBX or 10 Base-T cross cable (Rollover) Router When connecting the Hybrid IP-PBX directly to a router or PC, use a 10 Base-T Cross/Rollover cable. Use a 10 Base-T straight cable to connect the Hybrid IP-PBX to a switching HUB. Getting Started 13

14 2.2 Cable Connection 14 Getting Started

15 Section 3 Trunk Programming of the Hybrid IP-PBX Getting Started 15

16 3.1 Trunk Programming of the Hybrid IP-PBX 3.1 Trunk Programming of the Hybrid IP-PBX In order to assign Trunk Group Number to the IP trunk of the Hybrid IP-PBX, follow the procedure below. Note It is assumed that you have already installed the PC Programming Software in your PC. 1. Double-click "TDA PC Programming" icon. Pending 2. Type the password, then click [OK] to log-in. 3. Select "File" "New". 4. Double-click "Slot" under "Configuration". 5. Select "IP-GW4" for "Card Type" for the appropriate Slot, then click [OK]. 6. Double-click "CO" under "Line". 16 Getting Started

17 3.1 Trunk Programming of the Hybrid IP-PBX 7. Enter CO Name (max. 20 characters) and Trunk Group Number (01-64) for the desired "Trunk (CO) Number", then click [OK] to enable the setting. 8. Select "Connect" "Disconnect" to end configuration. Getting Started 17

18 3.1 Trunk Programming of the Hybrid IP-PBX 18 Getting Started

19 Section 4 Logical Installation (Maintenance Console Software) This section describes the logical installation process involving the following operations: (1) create New Groups and Gateway units, (2) configure common DNS Data, (3) configure unit-specific Office Data, and (4) upload configuration files and reboot the units. Getting Started 19

20 4.1 The Maintenance Console Software (MCS) 4.1 The Maintenance Console Software (MCS) MCS provides easy-to-use installation and management of the IP Gateway Card. This section describes the procedures to install and configure the IP Gateway Card for basic use. Use the MCS when installing the IP Gateway Card for the first time to establish the unit's new IP addressing through direct RS-232C link to the unit. Once this is done and units are on-line in the network, the MCS can be used to configure and troubleshoot units remotely. For a complete listing of all MCS features and functions, refer to the IP Gateway Card Programming Guide. System Requirements Microsoft Windows 95, Windows 98 or Windows NT 4.0 or later Minimum requirements (for installing Maintenance Console Software only) CPU: Pentium??? MHz RAM:??? MB HDD:??? MB Trademarks Microsoft, Windows and Windows NT are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Pentium is a trademark or a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. All other trademarks identified herein are the property of their respective owners Installing the MCS The MCS is shipped on CD-ROM. 1. a. Insert the CD-ROM into the PC's CD-ROM drive. b. Click "Maintenance Console Software Installer" on the initial screen. c. Click [OK]. d. Double-click "Setup.EXE" icon. 2. Follow the instructions to install the MCS. 20 Getting Started

21 4.1 The Maintenance Console Software (MCS) 3. When the installation is complete, 3 icons will be created Starting MCS and Logging-in 1. Double-click "IVG MCS" icon. Initial screen appears. 2. Type mcs (default password), then click [OK] to log-in. To change the default password, see Changing the Password MCS Main Directory Window Title Bar Menu Bar Tool Bar Unit Field Description and Sort Control Groups Window Pane Units Window Pane Status Bar Getting Started 21

22 4.1 The Maintenance Console Software (MCS) Serial Port Setting If a port other than COM 1 is used to connect the IP Gateway Card and the computer, the MCS serial communications parameter must be reconfigured. 1. Select "Tools" "Options". 2. Select "Serial port" of the PC that is used to connect the PC and the Hybrid IP-PBX, then click [OK] to complete the setting. 22 Getting Started

23 4.1 The Maintenance Console Software (MCS) Changing the Password 1. Select "Tools" "Options". 2. a. Click the "Password" tab. b. Enter the Current password. c. Enter and confrim the New password, then click [OK] to change the password. Getting Started 23

24 4.2 Creating New Group and Gateway 4.2 Creating New Group and Gateway When first setting up a VoIP network, Unit Groups must first be created. Once a new Unit Group has been created, New Gateways can be added to the group. Refer to the following steps and examples given in 1.2 Network Devices and Numbering Plan to create new Unit Groups and Gateways Creating a New Unit Group (Office) 1. Select "Unit" "New" "Group". 2. Enter Group Name and Comment, then click [OK] to create a new group Creating a New Gateway (IP Gateway Card) Each newly installed IP Gateway Card must first be initialized with its new IP addressing. To perform the following operation, the RS-232C cable must be connected to the unit and the COM port being used on the PC must be properly selected. Refer to RS-232C Cable Connection and Serial Port Setting. 1. Right-click the desired Group and select "New Gateway". Note: Do not select "New Gatekeeper", "New VoIP-TA", or "New Other unit". 24 Getting Started

25 4.2 Creating New Group and Gateway 2. Setup Wizard (1/6): a. Enter Name of the Gateway. b. Select "BV1250G" for "Unit", "V1.40" for "Version", and "BRIT" for "Interface". Note: Do not select any other value than above. c. Enter Comment for the Gateway (if necessary), then click [Next >]. 3. Setup Wizard (2/6): Enter IP Address, Subnet Mask, and Route Address of the Gateway, then click [Next >]. Consult your network administrator for specific values. 4. Setup Wizard (3/6): Enter "Call control signal TCP port no." (default: 1720), then click [Next >]. Consult your network administrator for specific values. 5. Setup Wizard (4/6): Check "Use Default Password" to accept the default Maintenance Level Password ("mainte"), then click [Next >]. Enter and confirm the Maintenance Level Password to change the default password, then click [Next >]. Getting Started 25

26 4.2 Creating New Group and Gateway 6. Setup Wizard (5/6): Check "Use Default Password" to accept the default User Level Password ("user"), then click [Next >]. Enter and confirm the User Level Password to change the default password, then click [Next >]. 7. Setup Wizard (6/6): Select "Option 2" and "RS232C" as the "Reboot access mothod", then click [Finish]. MCS updates the unit setup information of the unit. The unit reboot process can take over a minute to complete. A new Gateway is created. 26 Getting Started

27 4.3 Configuring Domain Name System (DNS) Data 4.3 Configuring Domain Name System (DNS) Data The function of a DNS in a VoIP network is to provide telephone number-to-ip Address translations *1. The IP Gateway Card has internal DNS database capabilities that can contain a maximum of 511 units in the network. DNS database is owned jointly by all units in the network (therefore it is necessary to update every unit with the latest DNS database whenever the network configuration is changed). For example numbering plan, refer to 1.2 Network Devices and Numbering Plan Editing DNS Data 1. a. Highlight "Main" in the Groups Window Pane. b. Select "Tools" "DNS (static transfer)" "Edit". 2. "Configure DNS setting" window appears. Click [Add]. 3. a. Enter Terminal number, Remaining digits, and Comment. b. Select the desired unit(s), then click [OK]. Configuration example of Los Angels telephone extensions ( ): PBX Office Code: 35 Telephone extension starting digit: 2 Remaining digits: 2 (i.e., 00-99) *1 IP address-to-telephone number translation can also be handled by using an H.323 Gatekeeper device. To configure Gatekeeper devices, refer to the manufacturer's documentation. This manual focuses on the method using the KX- TDA0480 internal DNS capabilities. Getting Started 27

28 4.3 Configuring Domain Name System (DNS) Data Los Angels telephone extension is now configured. 4. Repeat steps 1 to 3 and configure all DNS data, then click [Save] to end configuration. The IP Gateway Card creates the database for entire network as a simple text file named "DNS.DAT" in the Ccons12\System subdirectory. N 352 R2 I ;1720 N 355 R2 I ;1720 N 359 R7 I ;1720 N 413 R2 I ;1720 N 416 R2 I ;1720 N 419 R7 I ;1720 N: Terminal Number R: Remaining Digits I: Access IP Address 1720: Signal Port Number (default) To Los Angeles Office To Chicago Office 28 Getting Started

29 4.4 Configuring Office Data 4.4 Configuring Office Data Once a gateway unit is created, the MCS produces a configuration file (OFDD.VHO) containing the Office Data for the unit. Office Data is a generic term for configuration data set and stored in an IP Gateway Card. Edit the Office Data using the MCS so that each unit will operate properly in the network in which it is installed. The MCS permits all configuration file data to be entered and edited while off-line. In the procedures discussed in this section, the completed configuration files will be uploaded to the units using a LAN connection (see 4.5 Transferring the Data to the IP Gateway Card for details). 1. Right-click the desired gateway unit, and select "Edit configuration". 2. At "Edit configuration" window, select "Saved configuration file", then click [OK]. 3. Select "OFDD.VHO", then click [OK]. Selecting Custom Tone Sets a. Click the "Tone" tab. b. Select the suitable country, then click [OK]. Getting Started 29

30 4.4 Configuring Office Data Numbering Office Code a. Click the "Numbering" tab. b. Enter Office Code, then click [OK]. Setting Hunt Pattern a. Click the "Hunt pattern" tab. b. Click [OK]. Setting Trunk Data a. Click the "Trunk Data" tab. b. Click [OK]. 30 Getting Started

31 4.4 Configuring Office Data Presetting Fax Protocol a. Click the "FAX related" tab. b. Select "TCP" (default) or "UDP", then click [OK]. Setting Other Data a. Click the "Other" tab. b. Select "A-law" or "m-law" (default) for "Alaw/m-law flag"depending on the area in which the IP Gateway Card is used, then click [OK]. To configure the following parameters, please refer to Configure Gateway Units (KX- TDA0480) of IP Gateway Card Installation Manual. Trunk priority Voice mode Network Call Control SNMP Recovery delay Notify Priority routing information Getting Started 31

32 4.5 Transferring the Data to the IP Gateway Card 4.5 Transferring the Data to the IP Gateway Card Upon finishing all DNS and Office Data configuration using the MCS, please follow the procedure below to transfer the data to each Hybrid IP-PBX with IP Gateway Card in the network. Notes To transfer data using the following procedure, the Gateway parameters must have been previously uploaded. Refer to Creating a New Gateway (IP Gateway Card) for details. When transferring the data, the IP Gateway Card must be connected to the LAN. Refer to Base-T Cable Connection for details. 1. Select the desired unit(s), then select "Unit" "File Transfer". 2. Check "Config file (OFDD.VHO)", "DNS file (DNS.DAT)", and "Reboot after the transmission", then click [OK]. 32 Getting Started

33 4.6 Synchronising Time and Date of the IP Gateway Card 4.6 Synchronising Time and Date of the IP Gateway Card Loss of clock synchronisation of the IP Gateway Card will produce alarm indications under 2 conditions: (1) when the IP Gateway Card is newly installed to the Hybrid IP-PBX, or (2) when it has been disconnected from a power source for more than two months causing the battery discharge. However the alarm indications do not affect the IP Gateway Card operations, they should be corrected following the procedure below. Note When synchronising time and date, the IP Gateway Card must be connected to a PC (see Base-T Cable Connection). The IP Gateway Card's time and date will be synchronised with those of the PC with which the card is connected. 1. Select the desired unit(s), then select "Unit" "Time sync...". 2. Confirm the unit(s), then click [Execute]. Getting Started 33

34 4.6 Synchronising Time and Date of the IP Gateway Card 34 Getting Started

35 Section 5 Optimising Performance Getting Started 35

36 5.1 Preventing Problems 5.1 Preventing Problems Although the features of the IP Gateway Card go a long way toward assuring clear voice communications and error free fax transmission over digital data networks, some network conditions can cause performance degradations Voice Volume In some applications, voice volume may be either too low or too high. The gain control feature operates on both the incoming and outgoing sides and is referred to as the PAD control. The IP Gateway Card is able to optimize the gain or loss level of the voice signals. In most cases, it should not be necessary to modify the default PAD In (PAD value of the voice signals coming in to the unit)/pad Out (PAD value of the voice signals going out from the unit) settings. Indications that some adjustment is required are: Voice level too low: Increase gain by decreasing PAD level. Voice loud/distorted: Decrease gain by increasing PAD level. Excessive background noise: Decrease gain by increasing PAD level. To configure, please refer to Section Configure Gateway Units (KX-TDA0480) of IP Gateway Card Installation Manual Transmission Delays Transmission delays can cause delays and loss in voice communications and fax transmissions. These conditions typically arise when there is a high traffic on the LAN/WAN, causing excessive packet collisions. One preventative measure is to install Hybrid IP-PBX so that the number of transmission hops is kept to a minimum. In the figure below, the Hybrid IP-PBX is located as close to the WAN interface as possible. Too many HOPS! Better! (IP PBX located nearest WAN access point) Router Router Switch Switch Switch Switch IP PBX Hub Hub IP PBX 36 Getting Started

37 5.1 Preventing Problems Priority Control Some routers permit the configuration of priority control features. This allows the router to be configured to give higher priority to packets with high priority flags. The priority control feature should be used when available. To configure, please refer to Section Configure Gateway Units (KX-TDA0480) of IP Gateway Card Installation Manual Recovery Delay and Jitter Buffer When voice signals are packetised and transmitted, individual packet can take different paths through the network and arrive at the destination at varied timings (Jitter). The IP Gateway Card supports a secondary Jitter Buffer (max ms) in which the packets are accumulated temporarily for processing to compensate for network congestion problems. To configure, please refer to Configure Gateway Units (KX-TDA0480) of IP Gateway Card Installation Manual Internet, Intranet, and Virtual Private Networks (VPN) Manageable networks (e.g., Intranet, Leased Lines, VPN) provide better quality of service compared to unmanageable networks such as the Internet. When implementing a VoIP network, care must be taken when assessing bandwidth requirements. The IP Gateway Card uses 12 k per port when in use. Serialisation delays to the WAN are lower when higher bandwidths are used. When using the Internet/VPN, the ISP plays an important role in reducing the variable delay in the WAN. A regional or national ISP will usually have better connectivity with the backbone and will be able to guarantee greater service reliability than a local city ISP. When using VPN facilities, delays may be introduced due to the additional processing time required for encryption processing. Getting Started 37

38 This product complies with the essential requirements of the Directive 1999/5/EC Radio and telecommunications terminal equipment directive. Copyright: This manual is copyrighted by Kyushu Matsushita Electric Co., Ltd. (KME). You may print out this manual solely for internal use with KX-TDA0480. Except above, you may not reproduce this manual in any form, in whole or part, without the prior written consent of KME. Screenshots reprinted with permission from Microsoft Corporation Kyushu Matsushita Electric Co., Ltd. All Rights Reserved. Kyushu Matsushita Electric Co., Ltd. 1-62, 4-chome, Minoshima, Hakata-ku, Fukuoka , Japan Printed in Japan PSQX2538ZA KK0501HM0 (Rev. 7)

Getting Started. 16-Channel VoIP Gateway Card. Model No. KX-TDA0490

Getting Started. 16-Channel VoIP Gateway Card. Model No. KX-TDA0490 16-Channel VoIP Gateway Card Getting Started Model No. KX-TDA0490 Thank you for purchasing a Panasonic 16-Channel VoIP Gateway Card. Please read this manual carefully before using this product and save

More information

Hybrid IP-PBX Information about IP Proprietary Telephones KX-TDA200. Panasonic KX-TDA100 Panasonic KX-TDA200. Phone:

Hybrid IP-PBX Information about IP Proprietary Telephones KX-TDA200. Panasonic KX-TDA100 Panasonic KX-TDA200.  Phone: Panasonic KX-TDA100 Panasonic KX-TDA200 www.voicesonic.com Phone: 877-289-2829 Hybrid IP-PBX Information about IP Proprietary Telephones Model KX-TDA100 KX-TDA200 Panasonic KX-TDA100, KXTDA100, TDA100,

More information

Information about IP Proprietary Telephones KX-TDA30/KX-TDA100 KX-TDA200/KX-TDA600

Information about IP Proprietary Telephones KX-TDA30/KX-TDA100 KX-TDA200/KX-TDA600 Model No. Hybrid IP-PBX Information about IP Proprietary Telephones KX-TDA30/KX-TDA100 KX-TDA200/KX-TDA600 Thank you for purchasing a Panasonic Hybrid IP-PBX. Please read this manual carefully before using

More information

Information about IP Proprietary Telephones KX-TDA30/KX-TDA100 KX-TDA200/KX-TDA600. Hybrid IP-PBX. Model No.

Information about IP Proprietary Telephones KX-TDA30/KX-TDA100 KX-TDA200/KX-TDA600. Hybrid IP-PBX. Model No. Information about IP Proprietary Telephones Model No. Hybrid IP-PBX KX-TDA30/KX-TDA100 KX-TDA200/KX-TDA600 Thank you for purchasing a Panasonic Hybrid IP-PBX. Please read this manual carefully before using

More information

Thank you for purchasing a Panasonic Pure IP-PBX. Please read this manual carefully before using this product and save this manual for future use.

Thank you for purchasing a Panasonic Pure IP-PBX. Please read this manual carefully before using this product and save this manual for future use. IP Networking Guide Pure IP-PBX Model No. KX-TDE100 KX-TDE200/KX-TDE600 Thank you for purchasing a Panasonic Pure IP-PBX. Please read this manual carefully before using this product and save this manual

More information

Installation Manual. 4-Channel VoIP Gateway Card. Model No. KX-TDA0480

Installation Manual. 4-Channel VoIP Gateway Card. Model No. KX-TDA0480 4-Channel VoIP Gateway Card Installation Manual Model No. KX-TDA0480 Thank you for purchasing the Panasonic 4-Channel VoIP Gateway Card, KX-TDA0480. Please read this manual carefully before using this

More information

Programming Guide KX-TDA5480 KX-TDA Channel VoIP Gateway Card. Model

Programming Guide KX-TDA5480 KX-TDA Channel VoIP Gateway Card. Model 4-Channel VoIP Gateway Card Programming Guide Model KX-TDA548 KX-TDA484 Thank you for purchasing a Panasonic 4-Channel VoIP Gateway Card. Please read this manual carefully before using this product and

More information

Information about IP Proprietary Telephones KX-TDA50/KX-TDA100 KX-TDA200/KX-TDA600

Information about IP Proprietary Telephones KX-TDA50/KX-TDA100 KX-TDA200/KX-TDA600 Model Hybrid IP-PBX Information about IP Proprietary Telephones KX-TDA50/KX-TDA100 KX-TDA200/KX-TDA600 Thank you for purchasing a Panasonic Hybrid IP-PBX. Please read this manual carefully before using

More information

Installation Manual. Table of Contents. System Requirements. PC Phone Software. Model no. KX-TDA0350

Installation Manual. Table of Contents. System Requirements. PC Phone Software. Model no. KX-TDA0350 PC Phone Software Installation Manual Model no. KX-TDA0350 Thank you for purchasing the Panasonic PC Phone Software, KX-TDA0350. Please read this manual before using this product and save for future use.

More information

Getting Started KX-NCP500 KX-NCP1000. Pure IP-PBX. Model No.

Getting Started KX-NCP500 KX-NCP1000. Pure IP-PBX. Model No. Model No. Getting Started Pure IP-PBX KX-NCP500 KX-NCP1000 Thank you for purchasing a Panasonic Pure IP-PBX. Please read this manual carefully before using this product and save this manual for future

More information

Quick Reference Guide Model No. KX-NCS8100

Quick Reference Guide Model No. KX-NCS8100 IP Softphone Software Quick Reference Guide Model No. KX-NCS8100 Thank you for purchasing the Panasonic IP Softphone Software, KX-NCS8100. Please read this manual before using this product and save for

More information

Getting Started KX-NCP500 KX-NCP1000. Pure IP-PBX. Model No.

Getting Started KX-NCP500 KX-NCP1000. Pure IP-PBX. Model No. Model No. Getting Started Pure IP-PBX KX-NCP500 KX-NCP1000 Thank you for purchasing a Panasonic Pure IP-PBX. Please read this manual carefully before using this product and save this manual for future

More information

XN120 PC Pro with Quick Installer Guide Rev 1.2 (September 2005)

XN120 PC Pro with Quick Installer Guide Rev 1.2 (September 2005) This guide explains the PC programming tool with Quick Installer for the XN120 Telephone System. There is also a separate guide (991425-5 PCPro Getting Started Guide) that explains the operation of PCPro

More information

Programming Manual KX-TVA50 KX-TVA200. Voice Processing System. Model

Programming Manual KX-TVA50 KX-TVA200. Voice Processing System. Model Voice Processing System Programming Manual Model KX-TVA50 KX-TVA200 Thank you for purchasing a Panasonic Voice Processing System. Please read this manual carefully before using this product and save this

More information

Programming Manual KX-TVA50 KX-TVA200. Voice Processing System. Model

Programming Manual KX-TVA50 KX-TVA200. Voice Processing System. Model Voice Processing System Programming Manual Model KX-TVA50 KX-TVA200 Thank you for purchasing a Panasonic Voice Processing System. Please read this manual carefully before using this product and save this

More information

XN120 PC Pro Guide Getting Started Rev 1.2 (January 2007)

XN120 PC Pro Guide Getting Started Rev 1.2 (January 2007) This guide explains the PC programming tool, Pre config files, and common areas to customise from the Pre Config files for the XN120 Telephone System. The guide also explains the various methods of connecting

More information

Yealink VCS Network Deployment Solution

Yealink VCS Network Deployment Solution Yealink VCS Network Deployment Solution Oct. 2015 V10.6 Yealink Network Deployment Solution Table of Contents Table of Contents... iii Network Requirements... 1 Bandwidth Requirements... 1 Calculating

More information

User Manual A08. User Manual

User Manual A08. User Manual A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...

More information

Troubleshooting. Table of Contents. Network Camera. Troubleshooting Indoor Use only. Model No. BB-HCM311

Troubleshooting. Table of Contents. Network Camera. Troubleshooting Indoor Use only. Model No. BB-HCM311 Model No. BB-HCM311 Troubleshooting Network Camera Indoor Use only Table of Contents Troubleshooting... 3 Indicator Error Codes... 3 Camera Setup Difficulties... 4 Camera Image/Page Display... 7 Operation

More information

HOME AUTOMATION, INC. Model 93A00-1. Serial Server. User s Manual

HOME AUTOMATION, INC. Model 93A00-1. Serial Server. User s Manual HOME AUTOMATION, INC. Model 93A00-1 Serial Server User s Manual Document Number 93I00-1 Rev. A December, 2009 Introduction The 93A00-1 is a RS232/RS485 to TCP/IP converter integrated with a robust system

More information

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2 NET101 RS232 / RS422 / RS485 to Ethernet Converter User s Manual Version 1.2 Copyright Information Copyright 2004-2005, Mega System Technologies, Inc. All rights reserved. Reproduction without permission

More information

Getting Started KX-TVM50 KX-TVM200. Voice Processing System. Model No.

Getting Started KX-TVM50 KX-TVM200. Voice Processing System. Model No. Getting Started Voice Processing System KX-TVM50 KX-TVM200 Model No. Thank you for purchasing a Panasonic Voice Processing System. This manual shows you how to install and programme this product so that

More information

Configuring a GSM (3G) modem on a GW2040 Series Router

Configuring a GSM (3G) modem on a GW2040 Series Router Configuring a GSM (3G) modem on a GW2040 Series Router Issue 1.5 Date 10 May 2012 Table of contents 1 About this document... 3 1.1 Scope... 3 1.2 Readership... 3 1.3 More information... 3 1.3.1 Assigned

More information

Application Notes for Configuring Computer Instruments e-ivr, as a H.323 endpoint, with Avaya IP Office 500 V2 Issue 1.0

Application Notes for Configuring Computer Instruments e-ivr, as a H.323 endpoint, with Avaya IP Office 500 V2 Issue 1.0 Avaya Solution & Interoperability Test Lab Application Notes for Configuring Computer Instruments e-ivr, as a H.323 endpoint, with Avaya IP Office 500 V2 Issue 1.0 Abstract These Application Notes describe

More information

DMR Conventional Radio. SIP Phone Application Notes

DMR Conventional Radio. SIP Phone Application Notes DMR Conventional Radio SIP Phone Application Notes Copyright Information Hytera is the trademark or registered trademark of Hytera Communications Corporation Limited (the Company) in PRC and/or other countries

More information

TZ 170 Quick Start Guide

TZ 170 Quick Start Guide COMPREHENSIVE INTERNET SECURITY S o n i c WALL Internet Security Ap p l i a n c e s TZ 170 Quick Start Guide Quick Start Installation Thank you for purchasing a SonicWALL Internet security appliance. The

More information

SonicWALL TZ 150 Getting Started Guide

SonicWALL TZ 150 Getting Started Guide SonicWALL TZ 150 Getting Started Guide SonicWALL TZ 150 Security Appliance Getting Started Guide The SonicWALL TZ 150 is a total security platform delivering true layered security by integrating gateway

More information

Video Recording Transmitter. Installation Guide

Video Recording Transmitter. Installation Guide Video Recording Transmitter Installation Guide Notice: reserves the right to make improvements to the product described in this manual at any time and without notice. This manual is copyrighted. All rights

More information

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015) SMM Series 3G and GSM Modems Quick Start Guide Document Number: 0013-001-000272 () Documentation Control Generation Date: October 20, 2015 Cybertec Pty Limited All rights Reserved. No part of this publication

More information

NetBiter Serial Server User Manual

NetBiter Serial Server User Manual User Manual IntelliCom Innovation AB Linjegatan 3D SE-302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 17 29 09 email info@intellicom.se web www.intellicom.se Revision List Revision Date Author

More information

Operating Instructions

Operating Instructions KX-HGW500 WIRELESS LAN1 LAN2 LAN3 LAN4 INTERNET POWER Network Camera Management System Operating Instructions Model No. KX-HGW600 Please read this manual before using and save this manual for your future

More information

BB-HCE481 (PoE Type)

BB-HCE481 (PoE Type) Network Camera Indoor Use Only Model No. BB-HCM381 (AC Adaptor Type) BB-HCE481 (PoE Type) This manual is for both BB-HCM381 (AC Adaptor Type) and BB-HCE481 (PoE Type). Available features and operations

More information

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

SCS100/200/400 Quick Start Guide

SCS100/200/400 Quick Start Guide 900-320 Rev. A 9/25/03 4:07 PM Page 1 Secure Console Servers 2003 Copyright Lantronix is a registered trademark of Lantronix, Inc. All rights reserved. 900-320 Rev. A 9/03 900-320 Rev. A 9/25/03 4:07 PM

More information

EC-11 Ethernet Converter

EC-11 Ethernet Converter EC-11 Ethernet Converter PSTN Contact ID to TCP Converter Installation and Operations Manual Version 8.H3.MID 1 Table of Contents About EC-11 Ethernet Converter... 3 Circuit Board Layout and Wiring Diagram...

More information

Internet and Intranet Calling with PVX

Internet and Intranet Calling with PVX Internet and Intranet Calling with PVX An Application Note October 18, 2004 2004 POLYCOM, INC. ALL RIGHTS RESERVED. POLYCOM, THE POLYCOM LOGO, PVX, VIAVIDEO, AND PEOPLE+CONTENT ARE REGISTERED TRADEMARKS

More information

Ethernet Serial Server

Ethernet Serial Server Ethernet Serial Server Users Manual Eport-101, Eport-102, Eport-104, Eport108 1 INTRODUCTION... 1 1.1 FEATURES... 1 1.2 PRODUCT SPECIFICATIONS... 2 1.3 DEFAULT SETTINGS... 3 2 COMMUNICATION MODES... 4

More information

CHAPTER 7 ADVANCED ADMINISTRATION PC

CHAPTER 7 ADVANCED ADMINISTRATION PC ii Table of Contents CHAPTER 1 INTRODUCTION... 1 Broadband ADSL Router Features... 1 Package Contents... 3 Physical Details... 4 CHAPTER 2 INSTALLATION... 6 Requirements... 6 Procedure... 6 CHAPTER 3 SETUP...

More information

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual Lantech LSC-1102B SERIAL TO TCPIP CONVERTER User Manual V1.0 Sep 2016 Table of Contents 1. Introduction 3 Overview 4 Product Specifications 8 2. Description & Installation 10 Product Panel Views 10 LED

More information

Programming Manual KX-TVM50 KX-TVM200. Voice Processing System. Model No.

Programming Manual KX-TVM50 KX-TVM200. Voice Processing System. Model No. Programming Manual Voice Processing System KX-TVM50 KX-TVM200 Model No. Thank you for purchasing a Panasonic Voice Processing System. Please read this manual carefully before using this product and save

More information

Total Control System Application Guide

Total Control System Application Guide Total Control System Application Guide PPP Dial-in / IP Network / Channelized T1 HiPer ARC / HiPer DSP Part No. 1.024.1804-00 Version Number 1.0 Total Control System Application Guide Point-to-Point Protocol

More information

Canlan INSTALLATION MANUAL

Canlan INSTALLATION MANUAL Canlan INSTALLATION MANUAL August 2014 Table of Contents Introduction... 4 Overview... 5 RJ45 Connector and Status LEDs... 5 Power Input... 6 RS232 / RS485 Connectors... 7 Installing the Canlan Software...

More information

A more intelligent way to implement VoIP in remote offices and SOHO environments

A more intelligent way to implement VoIP in remote offices and SOHO environments Analog line and trunk interfaces Supports 2 simultaneous VoIP Calls Integrated IP router and firewall Transparent MultiPath Call Routing SelectNet assures superior voice quality A more intelligent way

More information

Programming Manual KX-TVA50 KX-TVA200. Voice Processing System. Model No.

Programming Manual KX-TVA50 KX-TVA200. Voice Processing System. Model No. Programming Manual Voice Processing System KX-TVA50 KX-TVA200 Model No. Thank you for purchasing a Panasonic Voice Processing System. Please read this manual carefully before using this product and save

More information

Installation and User Guide

Installation and User Guide Installation and User Guide Trademarks and Notices Notice Comtrol Corporation. SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS OF THIS PRODUCT FOR A PARTICULAR PURPOSE. Comtrol

More information

DGH A3000 Configuration Guide For use with DGH Modules

DGH A3000 Configuration Guide For use with DGH Modules DGH A3000 Configuration Guide For use with DGH Modules Revision Date: 12/07/05 Version: 1.00 Contact Information: http://www.dghcorp.com Ph: (603) 622-0452 Fax: (603) 622-0487 Mailing Address: DGH Corporation

More information

Getting Started KX-TDA100 KX-TDA200

Getting Started KX-TDA100 KX-TDA200 Model Hybrid IP-PBX Getting Started KX-TDA100 KX-TDA200 Thank you for purchasing a Panasonic Hybrid IP-PBX. Please read this manual carefully before using this product and save this manual for future use.

More information

VG5000 Analog Voice Gateway

VG5000 Analog Voice Gateway VG5000 Analog Voice Gateway Administrator Installation and Configuration Guide 07VG50M.AG1.08j.EN1 DSG, DSG logo, InterPBX, InterServer, Blaze Series, Savanna Series, VG5000, VG6000, IP580, IP500, InterClient,

More information

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

How to Configure an Avaya TM IP600 Server With MultiTECH Systems MVP200 Gateway - Issue 1.0

How to Configure an Avaya TM IP600 Server With MultiTECH Systems MVP200 Gateway - Issue 1.0 How to Configure an Avaya TM IP600 Server With MultiTECH Systems MVP200 Gateway - Issue 1.0 Abstract These Application notes describe the configurations that enable the Avaya IP600 Internet Protocol Communications

More information

Application Notes for Configuring Computer Instruments e-ivr, as a SIP endpoint, with Avaya IP Office 500 V2 Issue 1.0

Application Notes for Configuring Computer Instruments e-ivr, as a SIP endpoint, with Avaya IP Office 500 V2 Issue 1.0 Avaya Solution & Interoperability Test Lab Application Notes for Configuring Computer Instruments e-ivr, as a SIP endpoint, with Avaya IP Office 500 V2 Issue 1.0 Abstract These Application Notes describe

More information

User Manual Anybus Serial Server

User Manual Anybus Serial Server User Manual Anybus Serial Server Rev. 1.20:1 HMS Industrial Networks AB Germany Japan Sweden U.S.A UK + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29 20 + 1-773 - 404-3486 + 44 (0) 1908-359301 ge-sales@hms-networks.com

More information

Getting Started. Pure IP-PBX. Model No. KX-NS1000

Getting Started. Pure IP-PBX. Model No. KX-NS1000 Getting Started Pure IP-PBX Model No. KX-NS1000 Thank you for purchasing this Panasonic product. Please read this manual carefully before using this product and save this manual for future use. In particular,

More information

LevelOne Broadband Routers

LevelOne Broadband Routers LevelOne Broadband Routers FBR-1100TX FBR-1400TX FBR-1401TX FBR-1700TX User's Guide TABLE OF CONTENTS CHAPTER 1 INTRODUCTION... 1 Features of your LevelOne Broadband Router... 1 Package Contents... 4

More information

Expandable SIP Phone System. Expandable SIP Phone System

Expandable SIP Phone System. Expandable SIP Phone System Expandable SIP Phone System Key Features Included: + One DVX-1000 SIP IP PBX + One DIV-140 Trunk Gateway + Ten DPH-140S IP Telephones + Unified Management + Save On Long-distance Calling + Create an IP

More information

User s Manual ADSL Router Modem DB Ethernet Ports

User s Manual ADSL Router Modem DB Ethernet Ports User s Manual ADSL Router Modem DB 120 4 Ethernet Ports 1. About ADSL ADSL (Asymmetric Digital Subscriber Line) is a technology that allows high-speed data to be transmitted over existing copper telephone

More information

AT&T VOIP Nortel BCM 200/400 (Release 3.7 build 2.4f) Configuration Guide For Use with AT&T IP Flexible Reach Service. Issue 2.

AT&T VOIP Nortel BCM 200/400 (Release 3.7 build 2.4f) Configuration Guide For Use with AT&T IP Flexible Reach Service. Issue 2. AT&T VOIP Nortel BCM 200/400 (Release 3.7 build 2.4f) Configuration Guide For Use with AT&T IP Flexible Reach Service Issue 2.3 3/02/2007 Issue 2.3 Page 1 of 27 TABLE OF CONTENTS 1 Introduction... 4 1.1

More information

ELK-IP232 INSTALLATION AND CONFIGURATION MANUAL. Ethernet to Serial Bridge /07

ELK-IP232 INSTALLATION AND CONFIGURATION MANUAL. Ethernet to Serial Bridge /07 ELK-IP232 Ethernet to Serial Bridge INSTALLATION AND CONFIGURATION MANUAL http://www.ness.com.au email: support@ness.com.au 1/07 Table of Contents Features and Specifications...3 Basics of Networking...4

More information

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3 TRP-C37 Ethernet to RS232/422/485 Converter User s Manual Printed Apr.2014 Rev 1.3 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351 Fax:

More information

AT&T IP Flexible Reach And IP Toll Free Cisco Call Manager Configuration Guide. Issue /5/2007

AT&T IP Flexible Reach And IP Toll Free Cisco Call Manager Configuration Guide. Issue /5/2007 And IP Toll Free Cisco Call Manager Configuration Guide Issue 2.13 6/5/2007 Page 1 of 38 TABLE OF CONTENTS 1 Introduction... 3 2 Special Notes... 3 3 Overview... 4 3.1 Call Manager Site... 4 3.2 TFTP and

More information

User Manual. Call Centre Management Software. Model KX-A296/KX-A297

User Manual. Call Centre Management Software. Model KX-A296/KX-A297 Call Centre Management Software User Manual Model KX-A296/KX-A297 Please read this manual before using the Panasonic Call Centre Management Software. Thank you for purchasing a Panasonic Call Centre Management

More information

AirLive RS Security Bandwidth Management. Quick Setup Guide

AirLive RS Security Bandwidth Management. Quick Setup Guide AirLive RS-2000 Security Bandwidth Management Quick Setup Guide Important Information The AP mode s default IP address is The default Subnet Mask is The default login name is The default password is!!!!

More information

Quick Start Guide. 8-Port Value-Line Console Server QS Guide LES1508A

Quick Start Guide. 8-Port Value-Line Console Server QS Guide LES1508A LES1508A 8-Port Value-Line Console Server QS Guide Quick Start Guide This Quick Start Guide helps you through installation, configuration, and local operation. For more details, refer to the user manual

More information

Connection Guide (RS-232C)

Connection Guide (RS-232C) Programmable Controller CJ-series General-purpose Serial Connection Guide (RS-232C) MARS TOHKEN SOLUTION CO.LTD. Fixed Mount 2D Image Reader (MVF-300/500 Series) P679-E1-01 About Intellectual Property

More information

Network Camera. Troubleshooting... 3

Network Camera. Troubleshooting... 3 Network Camera Troubleshooting Indoor Use Only Model No. BL-C1 Table of Contents Troubleshooting... 3 Indicator Display Troubleshooting... 3 Camera Setup Troubleshooting... 5 Camera Image/Page Display

More information

Q&As. Interconnecting Cisco Networking Devices Part 1. Pass Cisco Exam with 100% Guarantee

Q&As. Interconnecting Cisco Networking Devices Part 1. Pass Cisco Exam with 100% Guarantee 640-822 Q&As Interconnecting Cisco Networking Devices Part 1 Pass Cisco 640-822 Exam with 100% Guarantee Free Download Real Questions & Answers PDF and VCE file from: 100% Passing Guarantee 100% Money

More information

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix) USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...

More information

INSTALLATION and OPERATION MANUAL

INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL Table of Contents Overview and Features.. 1 Specifications 2 Functional Block Diagram 3 Unit Detail. 4 DIP Switch Setting Tables 7 RS-232 I/F Pin Assignment.. 10 V.35

More information

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel Ethernet Module ETHM-2 Firmware version 1.0 ethm2_en 09/08 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.pl SATEL's goal is to continually improve

More information

Hardware Manual. PCMCIA 1 Port RS EDITION APRIL 1999

Hardware Manual. PCMCIA 1 Port RS EDITION APRIL 1999 Hardware Manual 232 232232 PCMCIA 1 Port RS232 1.1 EDITION APRIL 1999 Guarantee. FULL 36 MONTHS GUARANTEE. We guarantee your interface card for a full 36 months from purchase, parts and labour, provided

More information

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision 1.03.00 Motortronics / Phasetronics 1600 Sunshine Drive Clearwater, Florida 33765 Tel: 727-573-1819 Fax: 727-573-1803

More information

LM300 Manager User Manual. Document Version: 1.1 LM300 Firmware Version: Bluetooth Firmware Version:

LM300 Manager User Manual. Document Version: 1.1 LM300 Firmware Version: Bluetooth Firmware Version: LM300 Manager User Manual Document Version: 1.1 LM300 Firmware Version: 2.0.1 Bluetooth Firmware Version: 7.5.4279 LM300 Bluetooth Ethernet Access Point LM300 Manager User Manual i Revision Date Description

More information

TRP-C37 User s Manual

TRP-C37 User s Manual TRP-C37 User s Manual Ethernet to RS232/422/485 Converter Printed Oct. 2010 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172

More information

TC-UR24. USB to Serial port Adapter

TC-UR24. USB to Serial port Adapter TC-UR24 USB to Serial port Adapter Your Best Solution for PC-to-PLC Communication Overview The TC-UR24 USB-to-Serial port adapter is a low-cost high-performance single chip solution that provides bi-directional

More information

Quick Reference Guide CSTA Multiplexer. KX-NCP/KX-TDE Series KX-NS1000. Model No.

Quick Reference Guide CSTA Multiplexer. KX-NCP/KX-TDE Series KX-NS1000. Model No. Model No. Quick Reference Guide CSTA Multiplexer KX-NCP/KX-TDE Series KX-NS1000 Thank you for purchasing this Panasonic product. Please read this manual carefully before using this product and save this

More information

SIP Proxy Server. Administrator Installation and Configuration Guide. 08SIPXM.SY2.20a.EN2

SIP Proxy Server. Administrator Installation and Configuration Guide. 08SIPXM.SY2.20a.EN2 SIP Proxy Server Administrator Installation and Configuration Guide 08SIPXM.SY2.20a.EN2 DSG, DSG logo, InterPBX, InterServer, Blaze Series, Savanna, VG5000, VG6000, VG7000, IP590, IP580, IP500, IP510,

More information

KX-TDA TSP. Installation Manual. Revision: August 2010

KX-TDA TSP. Installation Manual. Revision: August 2010 R KX-TDA TSP Installation Manual Revision: 3.4.8.0 August 2010 Introduction About TSP Panasonic TAPI Service Provider for TDA/TDE/NCP Series (Panasonic KX-TDA TSP) is a driver that provides you with a

More information

Voice/Fax Over IP Networks Model MVP120. H.323 Mode. User Guide

Voice/Fax Over IP Networks Model MVP120. H.323 Mode. User Guide Voice / Fax over IP Networks 100 Voice/Fax Over IP Networks Model MVP120 H.323 Mode User Guide User Guide MultiVOIP Series 100 - Model MVP120 S0000223 Revision A Copyright This publication may not be reproduced,

More information

DeviceMaster RTS 16-Port Hardware Installation

DeviceMaster RTS 16-Port Hardware Installation DeviceMaster RTS -Port Hardware Installation Red underscored text link to Internet URLs. Blue underscored text link to sections within this document or to another document in the library. Note: If you

More information

Introduction. White Paper

Introduction. White Paper Using In-Band Channels for Management of Telecommunication Network Elements Loop Telecom s in-band management system is described. This is a robust technology for the management of remote network elements

More information

Network Camera. Troubleshooting... 3

Network Camera. Troubleshooting... 3 Network Camera Indoor Use Only Model No. BL-C20 Table of Contents... 3 Indicator Display... 3 Camera Setup... 5 Wireless Communication... 7 Camera Image/Page Display... 9 Operation Bar... 15 Image Buffer/Transfer...

More information

TELTONIKA ModemCOM (TMC-10x) User Manual V

TELTONIKA ModemCOM (TMC-10x) User Manual V TELTONIKA ModemCOM (TMC-10x) User Manual V2.1.1.18 TABLE OF CONTENTS ATTENTION!...3 LEGAL NOTICE...3 INTRODUCTION...4 1. PACKAGE CONTENTS...5 2. TECHNICAL SPECIFICATIONS...6 2.1. Data transferring...6

More information

Quick Start Guide. Remote Console Manager Quick Start Guide

Quick Start Guide. Remote Console Manager Quick Start Guide LES1202A-R2 LES1203A-M-R2 LES1204A-R2 Remote Console Manager Quick Start Guide Quick Start Guide This quick start guide helps you through installation, configuration, and local operation. For more details,

More information

SCS1600/3200 Quick Start Guide

SCS1600/3200 Quick Start Guide Secure Console Servers Quick Start Guide 2003 Copyright Lantronix is a trademark of Lantronix. All rights reserved. 900-233 Rev. D 11/03 QUICK START CONTENTS System Overview.......................................................2

More information

3G Router 431R/421R/321R/311R/221R/211R. Quick Start Guide

3G Router 431R/421R/321R/311R/221R/211R. Quick Start Guide 3G Router 431R/421R/321R/311R/221R/211R ---------------------------------------------------------- Version: 2.0----------------------------------------------------------- Check Package Contents: 3G Router

More information

BLE232: Manual Copyright 2014 taskit GmbH

BLE232: Manual Copyright 2014 taskit GmbH BLE232 Manual BLE232: Manual Copyright 2014 taskit GmbH BLE232 All rights to this documentation and to the product(s) described herein are reserved by taskit GmbH. This document was written with care,

More information

Operation Manual of EX9132CST-Series

Operation Manual of EX9132CST-Series Operation of EX9132CST-Series Serial to TCP/IP Converter (EX9132CST-2/ EX9132CST-RS485/ EX9132C-RS232) Version 1.0.0. 30.03.2017 Table of Contents 1 Introduction... 4 2 Overview... 5 2. 1 Package Checklist...

More information

HG658d Home Gateway. User Guide HUAWEI TECHNOLOGIES CO., LTD.

HG658d Home Gateway. User Guide HUAWEI TECHNOLOGIES CO., LTD. HG658d Home Gateway User Guide HUAWEI TECHNOLOGIES CO., LTD. HG658d Home Gateway V100R001 User Guide Issue 01 Date 2013-07-23 Part Number 202633 Huawei Technologies Co., Ltd. provides customers with comprehensive

More information

InterPhone. Operation Manual. DSG Technology, Inc. Voice Communication for Free.

InterPhone. Operation Manual. DSG Technology, Inc. Voice Communication for Free. InterPhone Operation Manual Voice Communication for Free DSG Technology, Inc. http://www.dsgtechnology.com TABLE OF CONTENTS Chapter 1 Understanding Your InterPhone 1-1 Overview 1-2 All-in-one Design

More information

VG-422R. User s Guide

VG-422R. User s Guide VG-422R User s Guide Trademarks Contents are subject to revise without prior notice. All trademarks belong to their respective owners. FCC Warning This equipment has been tested and found to comply with

More information

Longshine Technologie Europe GmbH

Longshine Technologie Europe GmbH Longshine Technologie Europe GmbH www.longshine.de TABLE OF CONTENTS COPYRIGHT...2 1. INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION...3 2. MFP SERVER INSTALLATION...5

More information

Application Notes for Telrex CallRex with Avaya IP Office - Issue 1.0

Application Notes for Telrex CallRex with Avaya IP Office - Issue 1.0 Avaya Solution & Interoperability Test Lab Application Notes for Telrex CallRex with Avaya IP Office - Issue 1.0 Abstract These Application Notes describe the procedures for configuring Telrex CallRex

More information

SST Configure Software OPERATION MANUAL

SST Configure Software OPERATION MANUAL SST Configure Software OPERATION MANUAL Trilithic Company Profile Trilithic is a privately held manufacturer founded in 1986 as an engineering and assembly company that built and designed customer-directed

More information

Connecting IP-PBX to BroadSoft's BroadCloud SIP Trunk using AudioCodes Mediant SBC

Connecting IP-PBX to BroadSoft's BroadCloud SIP Trunk using AudioCodes Mediant SBC Quick Guide AudioCodes Mediant Session Border Controllers (SBC) Connecting IP-PBX to BroadSoft's BroadCloud SIP Trunk using AudioCodes Mediant SBC Version 7.2 Introduction See Chapter 1 Obtain Software

More information

LevelOne FBR User s Manual. 1W, 4L 10/100 Mbps ADSL Router. Ver

LevelOne FBR User s Manual. 1W, 4L 10/100 Mbps ADSL Router. Ver LevelOne FBR-1416 1W, 4L 10/100 Mbps ADSL Router User s Manual Ver 1.00-0510 Table of Contents CHAPTER 1 INTRODUCTION... 1 FBR-1416 Features... 1 Package Contents... 3 Physical Details... 3 CHAPTER 2

More information

SERIAL TO ETHERNET CONVERTER E-P User Manual

SERIAL TO ETHERNET CONVERTER E-P User Manual SERIAL TO ETHERNET CONVERTER E-P132-100 User Manual 1 Table of Contents Introduction... 4 Overview.. 5 Package Checklist 6 Block Diagram 7 Product Features...8 Product Specifications 9 Converter Description

More information

Unified Office Gateway UMG-1000 / UMG-1000W. Quick Installation Guide

Unified Office Gateway UMG-1000 / UMG-1000W. Quick Installation Guide Unified Office Gateway UMG-1000 / UMG-1000W Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Overview... 4 3. Hardware Installation... 5 3.1 Removing the Chassis Cover... 5 3.2 The

More information

Security SSID Selection: Broadcast SSID:

Security SSID Selection: Broadcast SSID: 69 Security SSID Selection: Broadcast SSID: WMM: Encryption: Select the SSID that the security settings will apply to. If Disabled, then the device will not be broadcasting the SSID. Therefore it will

More information

Starter Guide Version Sphinx Access Control System

Starter Guide Version Sphinx Access Control System TC3XYMT/TC3XYNT Starter Guide Version 1.04.1 Sphinx Access Control System Page 1 1. Controller and Reader wiring...3 2. Connect the controller to PC...4 2.1. Setup the ID of Controller...4 2.2. Connect

More information

Polycom RSS 2000 Getting Started Guide

Polycom RSS 2000 Getting Started Guide Polycom RSS 2000 Getting Started Guide Version 4.0 March 2009 DOC2506A Copyright 2009 Polycom, Inc. All Rights Reserved All text and figures included in this publication are the exclusive property of Polycom,

More information