1 TECHNICAL INFORMATION GUIDE Alcatel 1642 Edge Multiplexer STM-1 Optical Multi-Service Node for Customer Premiser Equipment

2 The Alcatel 1642 Edge Multiplexer is a compact STM-1 Optical Multi Service Node that provides world-class next generation SDH functionality and capacity through aggregation of broadband multiprotocol traffic patterns. Designed for metro access and customer premises applications, the Alcatel 1642 Edge Multiplexer offers telecom carriers and service providers the powerful solution to build intelligent optical networks and achieve the optimal balance between new competitive service offerings and traditional revenue-generating services.

3 Table of Contents Introduction Advantages Applications General Description Functional Description SDH Cross-Connect Subsystem Clock Reference Subsystem Control Subsystem Compact ADM Interfaces Traffic Port Subsystem Auxiliary and Overhead Subsystem Power Subsystem Physical Description Technology Characteristics Technology Glossary

4 Introduction The Alcatel 1642 Edge Multiplexer is a Synchronous Add/Drop Multiplexer for SDH-to-the-customer applications. It is part of the OMSN (Optical Multiservice nodes) transmission equipment family, which comply with the Synchronous Digital Hierarchy (SDH) defined in ITU-T Recommendation G.707. Compatible with existing plesiochronous systems as well as with the installed SDH network, the 1642 Edge Multiplexer is a full ADM equipment operating at 155 (STM-1) MBit/s bit rate. It can be configured as a Multi Line Terminal Multiplexer or as an Add/Drop Multiplexer for point-to-point and ring applications. A wide range of different customer tributary signals can be multiplexed or added/dropped into STM-1 aggregates Edge Multiplexer has a symmetrical architecture whereby all traffic ports (PDH and SDH) of the same type have the same functionality and behavior and there is no inherent split between tributaries and aggregates. The traffic ports can be 2Mb/s, 34Mb/s, 45Mb/s, STM-1 optical and Ethernet/FE. A non-blocking matrix function allows full access to 6xSTM-1 equivalent payloads at the Low Order VC level Edge Multiplexer is composed of a very compact chassis and of plug-in units. The chassis can be mounted in 19 racks or used as desktop unit. Whether in telecommunication office environments or at enterprise locations, 1642 Edge Multiplexer has the right powering solution (DC or AC) and optional power redundancy can provide equipment protection. Alarms, performance monitoring, configuration setting and all information about the equipment status are available through the craft interface to a local personal computer and through the Q interface to the Network Management System. Network Management Systems can access the 1642 Edge Multiplexer via the SDH DCC network or directly via LAN. Both the interfaces to the local terminal and to the element manager are based on standard QB3 CMIP protocol stack and management messages. An orderwire channel, optionally available, facilitates link maintenance. Auxiliary channels are transmitted on the overhead bytes, according to ITU-T recommendations. STM-1 optical modules operating at 1300 nm and 1550 nm are available to cover short and long haul applications. TECHNICAL INFORMATION GUIDE ALCATEL 2 >

5 Advantages The main strategic advantages of the OMSN SDH ADM family are: Completeness: A comprehensive range of network elements for all transmission needs, from customer premises applications to metropolitan networks, to long-haul and ultra long-haul terrestrial and trans-oceanic applications. Everything under control of the same management system. Simplicity: The unnumbered possibilities offered by OMSN for network construction are provided by the fewest building blocks. Future-readiness: In addition to traditional transmission applications, OMSN deliver integrated ATM switching and Ethernet switching capabilities. Flexible nodes able to feature different networking functions are becoming vital in order to improve bandwidth utilization in data-dominated networks and to save extra-equipment costs. Backward-compatibility: OMSN guarantees full inter-working with the existing installed base in broad terms: from optical compatibility, to DCC (Data Communications Channels) compatibility, to network management. In other words, existing networks can be upgraded with new equipment without constraints. Management: No matter how the network is built or what networking technologies are used for edge and backbone applications (MPLS, ATM, SDH, WDM ) OMSN delivers one unified management solution. In addition, 1642 Edge Multiplexer brings the following specific benefits: Cost-effectiveness: Network operators can choose from a variety of units with an optimized number of ports, allowing them to buy just what they need. It allows the carrier to reduce the initial CAPEX while keeping the possibility of future upgrades. Full-ADM capabilities at end-customer premises: It can be used to deliver 2Mb/s and Ethernet/Fast Ethernet leased lines as well as higher-end services such as 34Mb/s, 45Mb/s, STM-1 with a versatile and compact chassis ideal for enterprise locations. It empowers the carrier s leased line service offering with the strong and extensive SDH end-to-end path control and monitoring capabilities Flexibility: A Compact ADM-1 card concentrates 2xSTM-1 interfaces, SDH matrix, clock reference and equipment control functions. 4 slots are dedicated to traffic ports, for 2Mb/s services and above. The system can be configured for example as STM-1 Terminal Multiplexer with 8x2Mb/s plus 6xEthernet/Fast Ethernet for office interconnect services or as STM-1 ADM with 112x2Mb/s. Reliability: 1642 Edge Multiplexer offers Sub-Network Connection Protection (SNCP). This allows to insert the 1642 Edge Multiplexer directly into access rings or to connect it to access rings via point-topoint unprotected or protected links. SNCP allows also end-to-end protection of SDH paths. Dual hubbing to two distinct central office ADMs is also possible Edge Multiplexer can also offer 48V power redundancy for equipment protection. Easiness: 1642 Edge Multiplexer has a centralized control architecture that limits the presence of processors and software to the Compact ADM-1 card. Traffic ports have no on-board processors and may be reused from one equipment to another or retrieved from stocks with no worries about software versions Edge Multiplexer also offers local and remote SW download, has the minimum possible set of replaceable items. TECHNICAL INFORMATION GUIDE ALCATEL 3 >

6 Applications The 1642 Edge Multiplexer can be used for transmission over G.652, G.653 and G.654 fibers. The main applications can be identified in the following areas: Delivery of SDH/Ethernet services to customer premises Local and metropolitan rings point to point links with intermediate drop/insert and/or regeneration stations; Metro Core/Backbone Metro Edge Metro Access Metro CPE General Description 1642 Edge Multiplexer is an STM-1 Network Element for transmission and cross-connection of a wide range of PDH and SDH signals. It can operate as a multi Terminal or Add/Drop Multiplexer Edge Multiplexer consists of the following parts: Chassis (four tributary slots) Compact ADM-1 unit (providing 2xSTM-1 optical + central functions) 1 Four slots for any traffic ports that can be of the following types: 8x2Mbit/s unit 28x2Mbit/s unit 1x34Mbit/s unit 1x45Mbit/s unit 1xSTM-1 optical unit 6xE/FE unit Figure Edge Multiplexer Application The Compact ADM unit provides the following functionalities: Up to 2 optical STM-1 modules SDH Matrix function CRU function Equipment controller function Auxiliary and order-wire function The Compact ADM-1 unit is used to terminate the network ring (or line). According to the network topology SNCP (Sub Network Connection Protection) inherent (SNCP/I) is provided at low order VCi levels Edge Multiplexer can realize non-intrusive Path Overhead Monitoring (POM) functions on 100% of Low Order and High Order VCs. Although the typical application for the 1642 Edge Multiplexer is in short reach urban rings, short and long haul optical interfaces are available for STM-1 applications. A centralized matrix implements the cross-connect function. It allows cross-connection between all traffic ports at all VCi (I=12,3) levels. The clock reference function, located in the Compact ADM unit synchronizes the 1642 Edge Multiplexer and provides generation and distribution of a synchronization clock. A wide auxiliary capacity, in accordance with SDH standards, is available for embedded services. An Engineering Order Wire channel, with DTMF signaling, can be accessed by a micro telephone for maintenance facility. TECHNICAL INFORMATION GUIDE ALCATEL 4 >

7 The clock reference function, located in the SDH matrix unit, synchronizes the 1642 Edge Multiplexer and provides generation and distribution of a synchronization clock. The clock can be locked to an external 2Mb/s source, to any STM-n or 2Mbit/s traffic ports or to the internal oscillator. The SSM (Synchronization Status Message) quality and priority algorithms are supported. The control subsystem is also placed on the compact ADM unit. The Equipment Controller function provides configuration, alarm status and performance monitoring data. A software download facility (Local and Remote) is available in order to update the complete software of the control subsystem. The system can be managed either by a CMISE Craft Terminal running on a Personal Computer attached to the F interface or by the Alcatel Network Management System through the Q interface. In case 1642 Edge Multiplexers are divided into several sub-networks by other non-alcatel equipments, an additional 2Mb/s interface on 8X2M Retiming Unit is available for DCC or EOW transparent transmission. DCC or EOW information can be encapsulated in a 2Mb/s data flow in the unit and be transmitted in the network. At last it will be terminated in another 1642 Edge Multiplexer. The system may be powered directly by station battery feed (-48V) or through an internal AC/DC converter. 1 Different optical modules can be mixed in the same unit. Each interface is managed independently. TECHNICAL INFORMATION GUIDE ALCATEL 5 >

8 Functional Description Multi Interface Multi Interface Multi Interface Multi Interface CARD 1 CARD 1 CARD 1 CARD 1 POWER SUPPLY FACEPLATE BACKPLANE F A N MAIN BORAD Qecc ADD/DROP MICRO BUS EC&SC ALL IN ONE PROCESSOR FROM/TO 4 CARD AND 2 OTM OH OH ADD/ DROP E1 BYTE ORDERWIRE TELCOM BUS System Clock SEC TELCOM BUS VC MATRIX 6 External Timing Sources Internal Oscillator TELCOM BUS TELCOM BUS OTM-1 TELCOM BUS TELCOM BUS OTM-1 P O W E R I N T E R F A C E F Q3 Rmt Alarms Houskeeping RS232 telphone External 2Mbps interface STM-1 Interface STM-1 Interface Figure Edge Multiplexer block diagram The equipment consists of the following subsystems: Compact ADM subsystem composed of: SDH VCi cross-connect matrix Clock Reference Equipment Control 2xSTM-1 interfaces Traffic port subsystem Auxiliary and overhead subsystem Power subsystem TECHNICAL INFORMATION GUIDE ALCATEL 6 >

9 SDH Cross-Connect Subsystem The 1642 Edge Multiplexer SDH cross-connect is built upon a non-blocking matrix that can interconnect VC3s and VC12s between any SDH and PDH ports accessing the system. Several types of connections may be established, such as: unidirectional point-to-point bi-directional point-to-point unidirectional point-to-multipoint SNCP Drop & Continue The capacity of the matrix is up to 6x6 STM-1 equivalent ports at the Low Order VC level (378 X 378 VC12s). STM-1 ports 34Mb/s 45Mb/s ports 2Mb/s ports Table 1. STM-1 ports 34Mb/s 45Mb/s ports 2Mb/s ports TU-3 TU-12 VC-3 VC-12 TU-3 Yes - Yes - TU-12 - Yes - Yes VC-3 Yes VC-12 - Yes - - Low Order Connectivity 1642 Edge Multiplexer The SDH VC matrix implements single-ended SNCP/I (inherent) protections. The protection mode may be revertive or non-revertive. Clock reference The synchronization subsystem provides the timing reference required by all components in the network element and represents the SDH Equipment Clock (SEC). The subsystem performs the functionality identified by the ITU-T recommendation G.783 as SDH Equipment Timing Source (SETS). The SETS function is realized by the SDH Matrix unit. A functional view of the SETS function in 1642 Edge Multiplexer is given in Figure 3 STM-n / 2Mb/s 2MHz / 2Mb/s SETG OSC Figure 3. Selector A Selector B OSC Squelch SETG Squelch Select C Synchronous Equipment Timing Generator Internal Oscillator function 1642 Edge Multiplexer SETS function The SETS accepts synchronization inputs from a number of sources: STM-n lines 2Mb/s traffic ports 2Mb/s external input internal oscillator Automatic selection of one of such sources is achieved by selector B using quality (SSM / Synchronization Status Message algorithm) or priority criteria. Also manual selection is possible. The SETS function produces two outputs. The NE clock reference is used as internal timing source and to time the outgoing SDH STM-n signals. One external 2Mb/s output is generated as a possible source for external devices. Up to 4 candidate references may be selected among all STM-n and 2Mb/s traffic ports in the system. 2Mb/s external input and output are available. When configured as 2Mb/s, the external I/Os can carry the SSM timing marker information. The SETG function has three modes of operation: locked, holdover and free-running. In holdover mode, the SETG holds the frequency of the last valid reference with a maximum drift of 0.37ppm per day. The accuracy of the local oscillator is ±4.6 ppm. 2MHz / 2Mb/s NE CLOCK REFERENCE TECHNICAL INFORMATION GUIDE ALCATEL 7 >

10 Control subsystem The control subsystem realizes the Synchronous Equipment Management Function (SEMF) defined by ITU-T Recommendation G.783. It communicates with external management systems through a standard QB3 CMIP interface. The management information model is compliant to the ITU-T G.774 series of recommendations. Communication with the local craft terminal is also based on the same interface. The control subsystem is responsible for applying the configuration requested by the element manager or craft terminal and to report the status of the equipment as well as alarm and performance information. It is also responsible to drive automatic protection switching Edge Multiplexer has a centralized control architecture, built upon a two-level model: Equipment Controller (EC) for DCC networking, CT/OS interface and data-base management Shelf Controller (SC) for provisioning, alarm detection, performance monitoring. The Shelf Controller processor implements the SDH functions in the shelf, for data collection (alarms, performance monitoring) and configuration provisioning purposes. The Message Communication Function (MCF) implemented by the Equipment Controller can manage up to 4 DCC channels (2 DCC channels on the middle row slots and 2 on Main control board). Selection of the STM-n ports and of the DCCm or DDCr channel is via Local Craft Terminal. Mass storage for the configuration database and SW loaded is provided by a replaceable PCMCIA Flash Card located in the Compact ADM unit. Compact ADM interfaces The Compact ADM unit provides direct access to 2 STM-1 interfaces on the unit front panel. This allows the realization of an unprotected ADM/Terminal Multiplexer configuration with a single board (excluding tributaries). The 2 STM-1 interfaces globally available in such a case may be used in any combination of unprotected (i.e. independent) and protected configurations (SNCP). Although physically located on the same unit that implements central functions (control, matrix,...) the Compact ADM STM-1 interfaces are totally equivalent to any other STM-1 interface available in the shelf. TECHNICAL INFORMATION GUIDE ALCATEL 8 >

11 Traffic Port Subsystem SDH and PDH traffic ports are available through the following units: 8x2Mbit/s Retiming unit (Coaxial Interface) 8x2Mbit/s unit (2mm Interface) 28x2Mbit/s unit (2mm Interface) 1x34Mbit/s unit 1x45Mbit/s unit 1xSTM-1 optical unit 6xE/FE unit 8x2Mbit/s Retiming unit (Coaxial Interface) The unit provides the physical interface for the asynchronous mapping of G.703 2Mb/s signals into SDH VC12s. Each unit supports 8 interfaces on the front panel. The unit implements the 2Mb/s retiming function. This allows applying the internal clock reference to outgoing 2Mb/s frames. Retiming can be enabled/disabled at the 2Mb/s port level. Another 2Mb/s coaxial interface is provided for DCC/EOW channel transparent transmission Edge Multiplexer can house up to 4 8x2Mb/s units in the shelf. 8x2Mbit/s unit (2mm Interface) The unit provides the physical interface for the asynchronous mapping of G.703 2Mb/s signals into SDH VC12s. Each unit supports 8 interfaces on the front panel. There are different units for 75Ω and 120Ω applications Edge Multiplexer can house up to 4 8x2Mb/s units in the shelf. 1x34Mbit/s unit (Coaxial Interface) The unit provides the physical interface for the asynchronous mapping of G Mb/s signals into SDH VC3s. Each unit supports 1 interface (75Ω) on the front panel Edge Multiplexer can house up to 4 1x34M units. 1x45Mbit/s unit (Coaxial Interface) The unit provides the physical interface for the asynchronous mapping of G Mb/s signals into SDH VC3s. Each unit supports 1 interface (75Ω) on the front panel Edge Multiplexer can house up to 4 1x45M units. 1xSTM1 Optical Unit The 1xSTM-1 optical unit provides one optical STM-1 interface on the front panel. Several short and long haul types are available Edge Multiplexer can house up to 4 1xSTM-1 units. The optical STM-1 interfaces can participate in any combinations of SNCP schemes that can flexibly be established by craft terminal or management system. 6xE/FE Unit The 6xE/FE unit provides 6 E/FE interfaces (on front panel). The 6 interfaces can be mapped together into 1-5 VC12 or 1-3 VC3 for point-to-point applications. The VCs are virtually concatenated Edge Multiplexer can house up to 4 6xE/FE units in the shelf. 28x2Mbit/s unit (2mm Interface) The unit provides the physical interface for the asynchronous mapping of G.703 2Mb/s signals into SDH VC12s. Each unit supports 28 interfaces on the front panel. There are different units for 75Ω and 120Ω applications Edge Multiplexer can house up to 4 28x2Mb/s units in the shelf. TECHNICAL INFORMATION GUIDE ALCATEL 9 >

12 Auxiliary and Overhead Subsystem The SDH standard offers a wide range of service channels in the Section Overhead (SOH) and Path Overhead (POH) bytes of the synchronous frame. These bytes are used for alignment word, parity check, network management operations, performance monitoring; some data and order wire channels are available to the user. Overhead bytes managed by the 1642 Edge Multiplexer are listed in Table 2, 3, 4, 5 RSOH bytes A1-A2 J0 B1 E1 F1 D1-D3 Table 2. MSOH bytes B2 D4-D12 S1 M1 E2 Description Framing bytes Section Trace RS Parity check RS Engineering OrderWire (EOW) 64kb/s user data channel RS DCC channels Supported Regenerator Section Overhead bytes Description MS Parity check MS DCC channels Synchronization Status Message (SSM) MS Remote Error Indication (REI) 64kb/s user data channels POH bytes V5 J2 Table 5. Supported VC12 Path Overhead bytes Table6 shows the SOH bytes available for local access (shadowed cells). Bytes reserved by standards to future or national use are marked with an x Edge Multiplexer provides the following auxiliary terminations: up to 12 x RS-232 (64kb/s) Note: only support point-to point application Table 6. Description Path Parity check, REI, RDI, Signal label Path Trace A1 A1 A1 A2 A2 A2 J0 x x 2 B1 x x E1 x x F1 x x RS-OH 3 D1 x x D2 x x D3 x x 4 AU-pointers 5 B2 B2 B2 x x x x 6 D4 x x D5 x x D6 x x 7 D7 x x D8 x x D9 x x MS-OH 8 D10 x x D11 x x D12 x x 9 S1 x x x x M1 E2 x x SOH bytes available for local access Table 3. Supported Multiplex Section Overhead bytes POH bytes J1 B3 C2 G1 F2 H4 Description Path Trace Path Parity check Signal label Path status indicator (REI, RDI) POH DCC channel Multiframe position indicator Table 4. Supported VC4/VC3 Path Overhead bytes TECHNICAL INFORMATION GUIDE ALCATEL 10 >

13 Power subsystem The transmission chassis can be powered either directly by a 48V DC station battery or by AC 220V. Optionally, a special fan board with 48V access and 48V/220V power board can be combined to provide Power Redundancy. TECHNICAL INFORMATION GUIDE ALCATEL 11 >

14 Physical Description The mechanical design of the 1642 Edge Multiplexer is based on a 19 ETSI compatible shelf. The mechanical dimensions of the shelf are the following: 443 mm Wide x 88 mm High x 295 Deep The mechanical design provides EMI/EMC performances, in compliance with ETSI standard Telecommunication Center. Figure Edge Multiplexer physical view (example configuration with 4xSTM1 + 8x2Mb/s + 6xE/FE) Figure 4 and figure 5 show the shelf layout in detail. To the left is the slot for the FAN unit (fan or fan with 48V access optional) To the right is the slot for the -48V or 220V power interface unit The top 2 rows provide 4 slots for traffic ports. These slots can be equipped with any of these units: 8x2Mbit/s Retiming unit (75Ω) 8x2Mbit/s unit (75Ωor 120Ω) 28x2Mbit/s unit (75Ωor 120Ω) 1x34Mbit/s unit 1x45Mbit/s unit 1xSTM-1 optical unit 6xE/FE unit The bottom row provides 1 slot for the Compact ADM-1 unit. The maximum quantity of each interface per shelf is: 112x2Mbit/s interfaces 4x34Mbit/s interfaces 4x45Mbit/s interfaces 6xSTM-1 optical interfaces 24xE/FE interfaces E/FE INTERFACE ON 6XE/FE UNIT QB3 INTERFACE 2Mb/s INTERFACE FOR DCC/EOW TRANSPARENCY 2mm HM E1 INTERFACE ON 28E1 UNIT E2, F1 64Kb/s DATA INTERFACE STM1OPTICAL INTERFACE ON STM1 UNIT -48V/220V CONNECTOR FAN WITH -48V ACCESS FOR POWER REDUNDANCY E1COAXIAL INTERFACE ON 8XE1 RETIMING UNIT F INTERFACE FROM LEFT TO RIGHT: OW, E2A, F1A, E2B, F1B, DBG_L (DEBUGGING), SO, SI (HOUSE KEEPING) 2Mb/s EXTERNAL CLOCK ALARM /RUNNING STATUS LED POWER SWITCH STM1OPTICAL INTERFACE ON COMPACT ADM-1 UNIT BECKET Figure Edge Multiplexer Mechanical Shelf Layout TECHNICAL INFORMATION GUIDE ALCATEL 12 >

15 Technology Characteristics Optical interface requirements System specification Type of fiber Wavelength Span length Application types Single mode, according to ITU-T G.652, G.653 and G nm, 1550nm Depending on fiber type and optical power budget reported in table7 TM and ADM in protected and unprotected linear links and rings STM-1 Optical interface type Optical connectors S-1.1, L-1.1, L-1.2 SC-PC Applied standards ITU-T G.703 for electrical interfaces ITU-T G.707 for SDH frame and multiplexing structure ITU-T G.957/958 for optical interfaces ITU-T G.821/G826 for transmission quality ITU-T G.813 for synchronization ITU-T G.783 for SDH equipment specification ITU-T G.841 for network protection architectures ITU-T G784/G774 for system management functions Interface requirements Electrical interfaces Optical interfaces Electrical interfaces general requirements Electrical interfaces impedance 2Mbit/s, 34Mbit/s, 45Mbit/s STM-1 ITU-T G.702/703 2Mbit/s 120Ohm Balance or 75 Ohm Unbalanced 34M, 45M 75 Ohm TECHNICAL INFORMATION GUIDE ALCATEL 13 >

16 Application code S-1.1 L-1.1 L-1.2 Operating wavelength range nm TRANSMITTER REFERENCE POINT S Source type MLM MLM SLM Spectral characteristics - maximum RMS width nm maximum -20dB width nm 1 - minimum side mode suppression ratio db 30 Mean launch power - maximum dbm minimum dbm Minimum extinction ratio db OPTICAL PATH BETWEEN S AND R Attenuation range db Maximum dispersion ps/nm Minimum optical return loss of cable plant at S including any connectors db NA NA 20 Maximum discrete reflectance NA NA -25 between S and R RECEIVER AT REFERENCE POINT R Type of detector In Ga As PIN In Ga As PIN In Ga As APD Minimum sensitivity (BER 10-10) dbm Minimum overload dbm Maximum optical path penalty db Maximum reflectance of receiver measured at R db NA NA -25 Table 7. STM-1 Optical interfaces TECHNICAL INFORMATION GUIDE ALCATEL 14 >

17 Add-drop and Cross-connect features Cross-Connection capacity Cross connect functionality Protection Network protection 6x6 STM-1 equivalent ports at VC12 and VC3 levels Aggregate to tributary Aggregate to aggregate Tributary to tributary Drop&Continue Loopback Broadcast SNCP/I Equipment Protection -48V power redundancy Data communication Network management D4-D12 or D1-D3 or F2 (max. 4 Channel per system) External alarms Housekeeping System alarms 3 inputs + 3outputs One LEDs on each traffic card (ALARM in current, ALARM in history, no ALARM) 8 LEDs in Main Control Board (RUN, POW, OTMA, OTMB, OW, CM, COMMON ALARM, SEVERITY ALARM) 3 LEDs in Faceplate (PWR, SALM, N-SALM) Operation interface Operation processes Station alarms NM access Information model Craft interface Engineering OW OW interface Urgent, non-urgent, alarm receiving attention, according to S9 specifications G.773 QB3/QB2 10 base 2 and 10 base T According to ITU-T (G.774) and ETSI specifications RS-232 PC compatible SUB-D 9 pins at 38kbps E1 access, DTMF in band signaling 64Kb/s G.703 co-directional Remote inventory Software download Performance monitoring Configuration provisioning and At card and sub-unit level Yes, without traffic interruption locally as well as remotely According to G.784, G.826 and G.821 Equipment, ports, add-drop, crossconnect, synchronization, protection, MCF, SEMF, OH connection Security Password, categories, back-up for programs and data Non volatile databases Yes Data channel Power specifications Software E2, F1 (max 12 x RS-232) in point-to programmable OH point application Battery 48 V DC/220V AC according to bytes DE/EE 2001 ETS Maximum dissipation power 40W per 1642 Edge Multiplexer subrack with 2xSTM-1, and 112x2Mbit/s interfaces TECHNICAL INFORMATION GUIDE ALCATEL 15 >

18 Mechanical specifications Equipment practice Sub-rack size Board size ETSI ETS/E3, S9 443W x 295D x 88H mm Traffic Board:230D x 165W mm MCB:230D x 349W mm Cooling Fan Electrical connectors IEC (coax. 1.0/2.3) Head Male (2mm) Access Mode Front access, rear access Environmental specifications Operating condition ETS , class 3.2 Storage condition ETS , class 1.2 Transportation condition EMI/EMC condition ETS , class 2.2 ETS , Telecommunication centers Hot replacement For traffic ports For STM-1 opt. No disturbance on other channels No disturbance on traffic Transmission delay For each type of cross-connection 125 s maximum for any traffic pathway Synchronization Equipment source options Clock inputs Clock outputs Synchronism selection timing Free run Accuracy. +/- 4.6ppm Holdover drift 0.37 ppm per day maximum 1 x 2048Kb/s G Ohm STM-N and 2Mbit/s interfaces 1 x 2048Kb/s G Ohm Priority and SSM algorithm TECHNICAL INFORMATION GUIDE ALCATEL 16 >

19 Technology Glossary ABN ADM AIS APS ATM ATTD AU AUX BA CRU DBR DTMF EC ECT EMI/EMC EOW EPROM EPS ETSI DXC IND ITU-T JE LED LOS MCF MSOH MSP ABNormal condition Add Drop Multiplexer Alarm Indication Signal Automatic Protection Switching Asynchronous Transfer Mode ATTendeD Administrative Unit AUXiliary Booster Amplifier Clock Reference Unit Deterministic Bit Rate Dual Tone Multi Frequency Equipment Controller Equipment Craft Terminal ElectroMagnetic Interference/ElectroMagnetic Compatibility Engineering Order Wire Electrically Programmable Read Only Memory Equipment Protection Switching European Telecommunication Standard Institute Digital cross Connect INDicative International Telecommunication Union Joint Engineering Light Emission Diode Loss Of Signal Message Communication Function Multiplex Section OverHead Multiplex Section Protection MS-SPRING Multiplex Section Shared Protection RING NE NURG Network Element Not URGent OFA OH OOF OS PDH POH ppm RSOH SBR SEMF SDH SNC-P SOH SSM STM TMN TSA TSI UBR URG VC VC-x VP Optical Fibre Amplifier OverHead Out Of Frame Operation System Plesiochronous Digital Hierarchy Path OverHead Parts per million Regeneration Section OverHead Statistical Bit Rate Synchronous Equipment Management Function Synchronous Digital Hierarchy Sub Network Connection Protection Section OverHead Synchronisation Status Message Synchronous Transport Module Telecommunication Management Network Time Slot Assignment Time Slot Interchange Unspecified Bit Rate URGent Virtual Channel Virtual Container x Virtual Path TECHNICAL INFORMATION GUIDE ALCATEL 17 >

20 Alcatel and the Alcatel logo are registered trademarks of Alcatel. All other trademarks are the property of their respective owners. Alcatel assumes no responsibility for the accuracy of the information presented, which is subject to change without notice. 12/2002 Alcatel. All rights reserved. 3AL AAAA Ed. 01

learntelecoms interactive e-learning suite of courses: SyncNet v6 SDH-based broadband networks SyncNet

learntelecoms interactive e-learning suite of courses: SyncNet v6 SDH-based broadband networks SyncNet Tel: 0845 0949 120 Email: info@ptt.co.uk Web site: www.ptt.co.uk SyncNet SyncNet v6 SDH-based broadband networks SyncNet is a suite of interactive, multimedia e-learning courses. provides training in the

More information

Alcatel 1660 SM Release 5

Alcatel 1660 SM Release 5 TECHNICAL INFORMATION GUIDE Alcatel 1660 SM Release 5 STM-64 Optical Multi-Service Node Introduction SDH (Synchronous Digital Hierarchy) is today the dominant transport technology in metropolitan and regional

More information

Datasheet. Multi-Service Access Platform OPCOM3500E-12. OPCOM3500E-12 Feature. Raisecom Technology Co., Ltd.

Datasheet. Multi-Service Access Platform OPCOM3500E-12. OPCOM3500E-12 Feature. Raisecom Technology Co., Ltd. Multi-Service Access Platform OPCOM3500E-12 OPCOM3500E-12 Feature Overview OPCOM3500E MSAP is carrier-class Multi-Service Access Platform, and designed to enable establishment of service-integrated for

More information

SDH Principle. Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved.

SDH Principle.   Copyright 2012 Huawei Technologies Co., Ltd. All rights reserved. SDH Principle www.huawei.com Objectives Upon completion of this course, you will be able to: Understand the basic of SDH multiplexing standard Know the features, applications and advantages of SDH based

More information

FCD-155. STM-1/OC-3 Terminal Multiplexer FEATURES

FCD-155. STM-1/OC-3 Terminal Multiplexer FEATURES FEATURES SDH/SONET terminal multiplexer for grooming LAN and legacy traffic (TDM) over SDH/SONET networks Demarcation point between the carrier and the customer networks GFP (G.7041), LAPS (X.85/86) encapsulation

More information

FCD-155. STM-1/OC-3 Terminal Multiplexer DESCRIPTION FEATURES

FCD-155. STM-1/OC-3 Terminal Multiplexer DESCRIPTION FEATURES DESCRIPTION FEATURES STM-1/OC-3 PDH/Ethernet terminal multiplexer for grooming LAN and legacy (TDM) traffic over SDH/SONET networks Ethernet traffic maps to: One VC-3/VC-4/STS-1 Up to 3 VC-3/STS-1 Up to

More information

STI 25 Edition 1/May 2002

STI 25 Edition 1/May 2002 STI 25 Edition 1/May 2002 Interface technical specifications for France Telecom s network As required by Directive 1999/5/EC Numeris Multisite Service (NMS) access interface characteristics Summary: This

More information

Network Topologies & Error Performance Monitoring in SDH Technology

Network Topologies & Error Performance Monitoring in SDH Technology Network Topologies & Error Performance Monitoring in SDH Technology Shiva Sharma Electronics and Communications Department Dronacharya College of Engineering Gurgaon, Haryana Shiva.92@hotmail.com Abstract

More information

This specification this document to get an official version of this User Network Interface Specification

This specification this document to get an official version of this User Network Interface Specification This specification describes the situation of the Proximus network and services. It will be subject to modifications for corrections or when the network or the services will be modified. Please take into

More information

LOOP-O 9100 STM1 ADM/TM

LOOP-O 9100 STM1 ADM/TM /TM LOOP-O 9100 /TM Description Loop- /TM is an economic compact & TM Multiplexer designed to add & drop up to: For 1U shelf: 56 x Tributaries 3 x DS3/E3 Tributaries with 28 4 x 10/100M Tributaries with

More information

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO F8016 Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO Description The fiber transmission platform is a fiber optic multiplexer with a fully new designing concept to challenge

More information

A.1 Cisco ONS CL Shelf Specifications. This section includes hardware and software specifications.

A.1 Cisco ONS CL Shelf Specifications. This section includes hardware and software specifications. APPENDIX A Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring

More information

DATACOM NG SDH Multiplexers. Multiservice functionalities with unlimited applications.

DATACOM NG SDH Multiplexers. Multiservice functionalities with unlimited applications. DATACOM NG SDH Multiplexers. Multiservice functionalities with unlimited applications. DATACOM NG SDH multiplexers count with multiservice functionalities for high capacity access, transport and data switching

More information

WaveStar ADM 16/1. Application and Planning Guide. Release CC Issue a September 2003

WaveStar ADM 16/1. Application and Planning Guide. Release CC Issue a September 2003 WaveStar ADM 16/1 Application and Planning Guide Release 6.2 Lucent Technologies Proprietary This document contains proprietary information of Lucent Technologies and is not to be disclosed or used except

More information

Compliant with ITU-T G.8262 (SyncE) for frequency synchronization; Compliant with IEEE (PTP) for phase and frequency synchronization

Compliant with ITU-T G.8262 (SyncE) for frequency synchronization; Compliant with IEEE (PTP) for phase and frequency synchronization itn2100 Multi Services Access Platform Raisecom s Multi-Service Access Platform offers a comprehensive deployment strategy for operators, carriers and ISPs with SDH-based applications. The MSAP product

More information

Transmission Technology Ses SDH

Transmission Technology Ses SDH Transmission Technology Ses SDH ALTTC/TX1/SDH/CONCEPTS 1 CONTENTS SDH PROTECTION PLANNING SYNCHRONISATION ALTTC/TX1/SDH/CONCEPTS 2 SDH: DISCUSSION AREA WHAT IS SDH? EVOLUTION DRIVING FORCES LIMITATIONS

More information

S Optical Networks Course Lecture 5: TDM-Based Networks

S Optical Networks Course Lecture 5: TDM-Based Networks S-72.3340 Optical Networks Course Lecture 5: TDM-Based Networks Edward Mutafungwa Communications Laboratory, Helsinki University of Technology, P. O. Box 2300, FIN-02015 TKK, Finland Tel: +358 9 451 2318,

More information

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO F8008 Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet + optional V.35/QFXS/QFXO Description F8008 is a fiber optical multiplexer of new generation different from the traditional PDH, multiplexing 1 full

More information

Gmux Modular TDMoIP Gateway FEATURES

Gmux Modular TDMoIP Gateway FEATURES FEATURES Carrier-class modular TDMoIP gateway, extending high capacity TDM traffic over packet-switched networks (PSNs) Operates opposite other members of RAD s TDMoIP family of products, offering a complete

More information

NGN - SYNCHRONOUS DIGITAL HIERARCHY

NGN - SYNCHRONOUS DIGITAL HIERARCHY NGN - SYNCHRONOUS DIGITAL HIERARCHY http://www.tutorialspoint.com/ngn/ngn_synchronous_digital_hierarchy.htm Copyright tutorialspoint.com SDH Networks replaced PDH and had several key advantages. G.707,

More information

V C ALIANT OMMUNICATIONS. VCL-4 E1 + Ethernet PDH Optical Multiplexer. Data Sheet U.K. INDIA U.S.A. Valiant Communications (UK) Ltd

V C ALIANT OMMUNICATIONS. VCL-4 E1 + Ethernet PDH Optical Multiplexer. Data Sheet U.K. INDIA U.S.A. Valiant Communications (UK) Ltd V C ALIANT OMMUNICATIONS VCL-4 E1 + Ethernet PDH Optical Multiplexer Data Sheet U.K. Valiant Communications (UK) Ltd Central House Rear Office 124 High Street, Hampton Hill Middlesex, TW12 1NS, U.K. E-mail:

More information

Optical Cards. 4.1 OC-N Cards OC-N Card Overview CHAPTER

Optical Cards. 4.1 OC-N Cards OC-N Card Overview CHAPTER CHAPTER 4 This chapter describes the Cisco ONS 15454 optical card features and functions. It includes descriptions, hardware specifications, and block diagrams for each optical card. For installation and

More information

MSE 5010 HARDWARE DESCRIPTION. M5010/EN FT/A11 Version A

MSE 5010 HARDWARE DESCRIPTION. M5010/EN FT/A11 Version A M5010/EN FT/A11 Version A TECHNICAL DOCUMENTATION M5010/EN FT/A11 Chapter No (if applicable) MSE 5010 Page 2/103 MSE 5010 Original signed by Date Name Visa Established 02/12/02/2004 Monique Wils Checked

More information

FMUX1001 Modularized 16E1/T1 + 4x GbE Managed Fiber Multiplexer FMUX101 Modularized 16E1/T1 + 4x FE Managed Fiber Multiplexer

FMUX1001 Modularized 16E1/T1 + 4x GbE Managed Fiber Multiplexer FMUX101 Modularized 16E1/T1 + 4x FE Managed Fiber Multiplexer Modularized 16E1/T1 Managed Multiplexer FMUX01 Modularized 16E1/T1 + 4x GbE Managed FMUX1 Modularized 16E1/T1 + 4x FE Managed The FMUX01/FMUX1 is a 1U, 19" rack mountable, PDH fiber optic multiplexer that

More information

V C ALIANT OMMUNICATIONS. VCL-Gigabit Ethernet over SDH (GigE) ( Gigabit Ethernet over STM- 4) Product Brochure

V C ALIANT OMMUNICATIONS. VCL-Gigabit Ethernet over SDH (GigE) ( Gigabit Ethernet over STM- 4) Product Brochure V C ALIANT OMMUNICATIONS VCL-Gigabit Ethernet over SDH (GigE) ( Gigabit Ethernet over STM- 4) Product Brochure U.K. Valiant Communications (UK) Ltd 1, Acton Hill Mews, 310-328 Uxbridge Road, London W3

More information

CPOS Interface. Synchronous digital hierarchy (SDH), defined by CCITT (today s ITU-T), uses a SONET rate subset.

CPOS Interface. Synchronous digital hierarchy (SDH), defined by CCITT (today s ITU-T), uses a SONET rate subset. SONET/SDH Synchronous Optical Network (SONET), a synchronous transmission system defined by ANSI, is an international standard transmission protocol. It adopts optical transmission where transmission rates

More information

Optimux-34, Optimux-25

Optimux-34, Optimux-25 Data Sheet Optimux-34, Optimux-25 16-Channel E1/T1, Ethernet or Data over E3 or Fiber Multiplexers Up to 16 E1/T1 links and high-speed data or Ethernet traffic multiplexed into fiber opt7ic uplink E3 copper

More information

FCD-155 STM-1/OC-3 Terminal Multiplexer

FCD-155 STM-1/OC-3 Terminal Multiplexer Data Sheet FCD-155 Transports LAN and TDM traffic over SDH/SONET networks STM-1/OC-3 PDH/Ethernet terminal multiplexer grooms LAN and legacy (TDM) traffic over SDH/SONET networks 10/100BaseT and GbE (Gigabit)

More information

STM-1/STM-4 Add-drop Multiplexer

STM-1/STM-4 Add-drop Multiplexer SAGEM-ADR622 STM-1/STM-4 Add-drop Multiplexer Product Description DTC SAGEM ADR622 AET/SYS/2009-D0351 01/09 Abbreviations EBER Excessive Bit Error Rate ECC Embedded Communication Channel EMC ElectroMagnetic

More information

D9408 Advanced ATM Adapter

D9408 Advanced ATM Adapter Digital Transmission Equipment D9408 Advanced ATM Adapter Description The D9408 Advanced ATM adaptor enables broadcasters and telecom operators to take advantage of the added flexibility and cost savings

More information

OPTI-6100 Series Optical Access Multi-Service Provisioning Platform (MSPP)

OPTI-6100 Series Optical Access Multi-Service Provisioning Platform (MSPP) OPTI-6100 Series Optical Access Multi-Service Provisioning Platform (MSPP) OPTI-6100 Series A high-density, compact, multi-service optical access and aggregation platform. Service providers globally have

More information

SONET. By Sadhish Prabhu. Unit II

SONET. By Sadhish Prabhu. Unit II SONET By Sadhish Prabhu History Digital carrier systems The hierarchy of digital signals that the telephone network uses. Trunks and access links organized in DS (digital signal) hierarchy Problem: rates

More information

Application Note. Re-timing: Cost-effective Synchronization via Re-timed E1 and DS1 Signals. Precision, Stability, Innovation, Support.

Application Note. Re-timing: Cost-effective Synchronization via Re-timed E1 and DS1 Signals. Precision, Stability, Innovation, Support. Re-timing: Cost-effective Synchronization via Re-timed E1 and DS1 Signals Application Note Number 14 TELECOM NETWORKS PROFESSIONAL MANUFACTURING POWER & UTILITIES DIGITAL BROADCASING TIME & FREQUENCY TIME

More information

H9MO-LMFE SDH/MSPP multiplexer

H9MO-LMFE SDH/MSPP multiplexer Overview: H9MO-LMFE SDH/MSPP multiplexer H9MO-LMFE is a carrier-class, cost-effective, compact (only 1U high), STM-1/STM-4/STM-16 SDH/MSPP platform that is designed for application in metro and access

More information

E1-E2 (EB) Chapter 1 MLLN

E1-E2 (EB) Chapter 1 MLLN E1-E2 (EB) Chapter 1 MLLN MLLN Drawback Of Traditional Leased Line Circuits No Intramedia in between. Grew from 64 kbps they have to jump over to 2 Mbps only. Data Cards support only upto 64 Kbps From

More information

DESCRIPTION. Features

DESCRIPTION. Features Multi-Ser vice Access Network Features Combined SONET - SDH ADM and E1/T1- PDH multiservice DACS 6U height, full front access (ETSI) shelf TM, ADM and DCS at DS0, VC12, VC3, VC4 Dual STM-1/4 - OC-3/12

More information

System Applications Description

System Applications Description NT7E65DJ 323-1111-150 SONET Transmission Products S/DMS TransportNode / NE TBM System Applications Description Standard Rel 14 February 2001 What s inside... / network element applications Copyright 1992

More information

Installing ONS SDH OC3 IR 4/STM1 SH 1310 Cards

Installing ONS SDH OC3 IR 4/STM1 SH 1310 Cards Installing ONS 15454 SDH OC3 IR 4/STM1 SH 1310 Cards Product Name: 15454E-S1.1-4= This document contains a description of OC3 IR 4/STM1 SH 1310 card features, installation procedures, removal instructions,

More information

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

Optimux-1553 STM-1/OC-3 Terminal Multiplexer Data Sheet Optimux-1553 STM-1/OC-3 terminal multiplexer for grooming high order legacy traffic (TDM) over SDH/SONET networks Any Traffic Over Fiber Multiplexes up to three E3 or T3 data channels using

More information

One platform - multiple choices

One platform - multiple choices One platform - multiple choices AXXMETRO is part of AXXESSIT's Multi-Service Provisioning Platform, that can deliver a mix of voice and/or high-speed data services at a fraction of the cost of traditional

More information

Alcatel 1696 Metro Span. Metropolitan DWDM System

Alcatel 1696 Metro Span. Metropolitan DWDM System Alcatel 1696 Metro Span Metropolitan DWDM System In metropolitan areas, the need for higher bandwidth and valueadded services is becoming increasingly critical. Service providers must find flexible and

More information

16 x E1 G x Ethernet optical multiplexer

16 x E1 G x Ethernet optical multiplexer 16 x E1 G.703 + 4 x Ethernet optical multiplexer Spot-light: 16E1+4Eth Optical multiplexer is state-of-art 16 x E1 G.703 + Ethernet 10/100BaseT fiber multiplexer with logical bandwidth control, QoS, and

More information

Final draft ETSI EN V1.4.1 ( )

Final draft ETSI EN V1.4.1 ( ) Final draft EN 300 147 V1.4.1 (2001-05) European Standard (Telecommunications series) Transmission and Multiplexing (TM); Synchronous Digital Hierarchy (SDH); Multiplexing structure 2 Final draft EN 300

More information

Optimux-1553 E3/T3 STM-1/OC-3 Terminal Multiplexer

Optimux-1553 E3/T3 STM-1/OC-3 Terminal Multiplexer Data Sheet Optimux-1553 STM-1/OC-3 terminal multiplexer for grooming high-order legacy traffic (TDM) over SDH/SONET networks Up to three E3 or T3 data channels multiplexed using a single hot-swappable

More information

ITU-T G.832. Transport of SDH elements on PDH networks Frame and multiplexing structures

ITU-T G.832. Transport of SDH elements on PDH networks Frame and multiplexing structures INTERNATIONAL TELECOMMUNICATION UNION ITU-T G.832 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (10/98) SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Digital transmission systems

More information

Suppliers' Information Note. BT International Megastream 155. Service Description

Suppliers' Information Note. BT International Megastream 155. Service Description SIN 326 Issue 1.3 January 2016 Suppliers' Information Note For The BT Network BT International Megastream 155 Service Description Each SIN is the copyright of British Telecommunications plc. Reproduction

More information

Telecom Point to Point Radio

Telecom Point to Point Radio RADTR-P2P-6-38-IP170MB-a9 Telecom Point to Point Radio PDH 4-16E1s/E3 and/or Ethernet up to 170Mbps 6-38GHz Applications Ethernet IP Cellular Backhaul TDM/PDH/IP Radio Networks Trunking or Access Networks

More information

For internal circulation of BSNL only

For internal circulation of BSNL only E3-E4 E4 (CFA) Overview of SDH AGENDA SDH & PDH Hierarchy SDH Network Survivability Synchronous All elements are synchronized with one master clock. DIGITAL Information is in binary. SDH OVERVIEW HIERARCHY

More information

ORION TELECOM NETWORKS INC. STM-1 (Optical / Electrical) Add-Drop Multiplexer (with upto 16 E1 & 4 Ethernet) SDH Equipment

ORION TELECOM NETWORKS INC. STM-1 (Optical / Electrical) Add-Drop Multiplexer (with upto 16 E1 & 4 Ethernet) SDH Equipment RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. (with upto 16 E1 & 4 Ethernet) SDH Equipment Product Brochure Headquarters: Phoenix, Arizona Orion Telecom Networks Inc. 20100, N 51stAve, Suite B240,

More information

EUROPEAN ETS TELECOMMUNICATION April 1997 STANDARD

EUROPEAN ETS TELECOMMUNICATION April 1997 STANDARD EUROPEAN ETS 300 147 TELECOMMUNICATION April 1997 STANDARD Third Edition Source: ETSI TC-TM Reference: RE/TM-03045 ICS: 33.020 Key words: Transmission, mux, SDH Transmission and Multiplexing (TM); Synchronous

More information

XMP1 Product Family. Flexible Cross Connect System and Add/Drop Multiplexer for mission critical networks

XMP1 Product Family. Flexible Cross Connect System and Add/Drop Multiplexer for mission critical networks XMP1 Product Family Flexible Cross Connect System and Add/Drop Multiplexer for mission critical networks XMP1 Content Dedicated Networks Technical Data XMP1 Introduction XMP1 Applications XMP1-SL Benefits

More information

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options: FEATURES E1 or Fractional E1 access unit Supports one data port with selectable sync data rates: n x 56, n x 64 kbps Optional sub-e1 drop & insert port for PABX connectivity Single slot supports MEGAPLEX

More information

Optimux-4T1 Four-Channel T1 Multiplexer

Optimux-4T1 Four-Channel T1 Multiplexer Data Sheet Optimux-4T1 Any Traffic Over Fiber Multiplexes four T1 channels over a fiber optics link with various fiber interfaces: multimode, single-mode (up to 120 km), and single-mode over single fiber

More information

ORION TELECOM NETWORKS INC.

ORION TELECOM NETWORKS INC. RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. VCL-Gigabit Ethernet over SDH (GigE) ( Gigabit Ethernet over STM- 4) Product Brochure Headquarters: Phoenix, Arizona Orion Telecom Networks Inc. 20100,

More information

FCD-155 STM-1/OC-3 Terminal Multiplexer

FCD-155 STM-1/OC-3 Terminal Multiplexer Data Sheet FCD-155 Transports LAN and TDM traffic over SDH/SONET networks Groomed LAN and legacy (TDM) traffic over SDH/SONET networks VLAN and point-to-multipoint switching Ethernet traffic mapped to

More information

Loop-O9330 Fiber Optical Mux

Loop-O9330 Fiber Optical Mux Loop-O9330 Fiber Optical Mux Features Up to 16 E1 links and one 100Mbps ethernet link on one fiber Auto Laser Shutdown function is user configurable Supports 10/100M Ethernet Bridge plug-in card (Optional)

More information

Connection Master. Mission critical multiservice access platform for utility, corporate and enterprise customers

Connection Master. Mission critical multiservice access platform for utility, corporate and enterprise customers DP10001708 1 Mission critical multiservice access platform for utility, corporate and enterprise customers provides true multiservice capabilities to support a very wide range of legacy voice and data

More information

V C ALIANT OMMUNICATIONS. VCL-Gigabit Ethernet over SDH. Product Brochure. Copyright: Valiant Communications Limited U.K. INDIA U.S.A.

V C ALIANT OMMUNICATIONS. VCL-Gigabit Ethernet over SDH. Product Brochure. Copyright: Valiant Communications Limited U.K. INDIA U.S.A. V C ALIANT OMMUNICATIONS VCL-Gigabit Ethernet over SDH ( Gigabit Ethernet over STM-1) Product Brochure U.K. Valiant Communications (UK) Ltd 1, Acton Hill Mews, 310-328 Uxbridge Road, London W3 9QN United

More information

Backbone network technologies. T Jouni Karvo, Timo Kiravuo

Backbone network technologies. T Jouni Karvo, Timo Kiravuo Backbone network technologies T-110.300 Jouni Karvo, Timo Kiravuo Backbone network technologies This lecture tells about backbone networks After this lecture, you should know WDM, PDH, SDH and ATM understand

More information

V C ALIANT OMMUNICATIONS. VCL-Ethernet over SDH (Ethernet over STM-1) Product Brochure. Copyright: Valiant Communications Limited U.K.

V C ALIANT OMMUNICATIONS. VCL-Ethernet over SDH (Ethernet over STM-1) Product Brochure. Copyright: Valiant Communications Limited U.K. V C ALIANT OMMUNICATIONS VCL-Ethernet over SDH (Ethernet over STM-1) Product Brochure U.K. Valiant Communications (UK) Ltd 1, Acton Hill Mews, 310-328 Uxbridge Road, London W3 9QN United Kingdom E-mail:

More information

INTERNATIONAL TELECOMMUNICATION UNION

INTERNATIONAL TELECOMMUNICATION UNION INTERNATIONAL TELECOMMUNICATION UNION )454 ' TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (08/96) SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Digital transmission systems

More information

OPCOM STM-1 High Capacity Terminal Multiplexer USER MANUAL. Raisecom Technology Co., Ltd (4/2005)

OPCOM STM-1 High Capacity Terminal Multiplexer USER MANUAL. Raisecom Technology Co., Ltd (4/2005) OPCOM3100-155 STM-1 High Capacity Terminal Multiplexer USER MANUAL Raisecom Technology Co., Ltd (4/2005) 1. Cautions Please read the following notices carefully before installing and using the device,

More information

FCD-155E STM-1/OC-3 Add/Drop Multiplexer

FCD-155E STM-1/OC-3 Add/Drop Multiplexer Data Sheet FCD-155E STM-1/OC-3 add/drop multiplexer that transports LAN and traditional (TDM) traffic over SDH/SONET networks STM-1/OC-3 PDH/Ethernet add/drop multiplexer for grooming LAN and legacy (TDM)

More information

FCD-155 STM-1/OC-3 Terminal Multiplexer

FCD-155 STM-1/OC-3 Terminal Multiplexer Where to buy > See the product page > Data Sheet Groomed LAN and legacy (TDM) traffic over SDH/SONET networks VLAN and point-to-multipoint switching Transports LAN and TDM traffic over SDH/SONET networks

More information

Introduction Metro Area Optical Networks Components of a MAN Metro Service POP Core MAN Services Access Services Metro Optical Services Service POP

Introduction Metro Area Optical Networks Components of a MAN Metro Service POP Core MAN Services Access Services Metro Optical Services Service POP Introduction Metro Area Optical Networks Components of a MAN Metro Service POP Core MAN Services Access Services Metro Optical Services Service POP Services Core Services MAON Physical Topologies Four

More information

FPGA BASED IMPLEMENTATION OF STM-16 FRAMER IP CORE

FPGA BASED IMPLEMENTATION OF STM-16 FRAMER IP CORE FPGA BASED IMPLEMENTATION OF STM-16 FRAMER IP CORE 1 T.SHIVARAJA, 2 RASHMI PRIYADARSHINI, 3 RAJA JITENDRA NAYAKA 1 Mtech-4th Sem,ECE department, RITM Yelahanka Bangalore, Karnataka, India 2 Asst. Professor,

More information

Optical networking: is the Internet of the future already here?

Optical networking: is the Internet of the future already here? Optical networking: is the Internet of the future already here? Emilie CAMISARD Renater Optical technologies engineer - Advanced IP Services e-mail: camisard@renater.fr 23/11/04 ATHENS - Optical networking

More information

CMA 3000, all-in-one field tester SDH test options

CMA 3000, all-in-one field tester SDH test options CMA 3000, all-in-one field tester SDH test options KEY FEATURES Simultaneous bidirectional monitoring of SDH lines Powerful testing of SDH systems and embedded PDH systems Mapping and demapping Comprehensive

More information

What is SDH? Telecommunications Standards Primer. Plesiochronous Digital Hierarchy (PDH) Limitations of PDH Network

What is SDH? Telecommunications Standards Primer. Plesiochronous Digital Hierarchy (PDH) Limitations of PDH Network Página 1 de 7 Telecommunications Standards Primer What is SDH? This document is intended as an introductory guide to the Synchronous Digital Hierarchy (SDH) standard. The following is a representative

More information

LOOP-O9100 ADM/TM. Description. Features CERTIFIED ISO-9001 ADM/TM

LOOP-O9100 ADM/TM. Description. Features CERTIFIED ISO-9001 ADM/TM ADM/TM Features 1U and 3U case option TM, ADM Fully front access option (ETSI) Multiple Tributary modules (option): 4/12/20/28-channel /DS1 on base unit 28-channel /DS1 module 1/3-channel E3/DS3 module

More information

Data Center & Cloud Computing DATASHEET. FS.COM WDM Transport Networks Data Center & Cloud Computing Infrastruture Solutions

Data Center & Cloud Computing DATASHEET. FS.COM WDM Transport Networks Data Center & Cloud Computing Infrastruture Solutions Data Center & Cloud Computing DATASHEET FS.COM WDM Transport Networks Data Center & Cloud Computing Infrastruture Solutions REV.1.0 2018 01 Overview About the Features Efficient Usage Supports up 18 to

More information

Optimux-34 Fiber Optic Multiplexer

Optimux-34 Fiber Optic Multiplexer Data Sheet Optimux-34 Multiple E1, Ethernet, or High-speed Data over E3 or Fiber, up to 110 km (68 miles) Up to 16 E1 links, high-speed data, and Ethernet traffic multiplexed into one E3 copper or fiber

More information

FOM-FXO32 / FOM-FXS32 32 Voices (FXS/FXO) POTS Fiber Multiplexer

FOM-FXO32 / FOM-FXS32 32 Voices (FXS/FXO) POTS Fiber Multiplexer Voice POTS Fiber Multiplexer NEW FOM-FXO32 / FOM-FXS32 32 Voices (FXS/FXO) POTS Fiber Multiplexer The FOM-FXO32/FXS32 are a 1U, 19 Rack mountable voice transmission fiber multiplexers that transmits up

More information

Synchronisation Supply Unit for PDH & SDH networks

Synchronisation Supply Unit for PDH & SDH networks SSU-32 Synchronisation Supply Unit for PDH & SDH networks With the ever increasing stringent requirements of new broadband technologies and new multimedia high demanding applications, synchronisation matter

More information

VCL-TP, Teleprotection Equipment

VCL-TP, Teleprotection Equipment VCL-TP, Teleprotection Equipment Data Sheet Copyright: Valiant Communications Limited. - 2013 1 Product Overview VCL-TP, Teleprotection Equipment is an extremely reliable and flexible product that offers

More information

Optical Fiber Communications. Optical Networks- unit 5

Optical Fiber Communications. Optical Networks- unit 5 Optical Fiber Communications Optical Networks- unit 5 Network Terminology Stations are devices that network subscribers use to communicate. A network is a collection of interconnected stations. A node

More information

TECHNOLOGY PAPER ON HIGH CAPACITY DWDM NETWORK

TECHNOLOGY PAPER ON HIGH CAPACITY DWDM NETWORK DOCUMENT NO.: PBT 132 Copyright Commtel D. N. S. (India) Pvt. Ltd. TABLE OF CONTENTS 1 INTRODUCTION... 3 2 SCOPE... 3 3 DWDM TECHNOLOGY... 3 4 FIBERS SUPPORTING DWDM... 5 5 DWDM ARCHITECTURES... 6 6 NOKIA

More information

CMA 5000 extended Transport Analysis Application

CMA 5000 extended Transport Analysis Application CMA 5000 extended Transport Analysis Application Applications CMA 5000 The Field Portable Solution for Installation, Commissioning and Maintenance of SONET/SDH Networks (ready for NGN) The compact size

More information

E1-E2 (EB) Chapter 4 MSPP

E1-E2 (EB) Chapter 4 MSPP E1-E2 (EB) Chapter 4 MSPP Page: 1 Multi-service Provisioning Platform (M S P P) I) Introduction: MSPP is deployed in the boundary of Access and Metro core backbone. TEC has prepared two different platforms

More information

iaccess Multi-Service Platform-DM In Band Managed Multi-Service Platform-FRM220 Series

iaccess Multi-Service Platform-DM In Band Managed Multi-Service Platform-FRM220 Series iaccess TM Multi-Service Platform-DM In Band Managed Multi-Service Platform-FRM220 Series Mobile Fronthaul & Backhaul for 4G LTE 10G Ethernet for Data Center Solution Carrier Ethernet (NID & EDD) CWDM

More information

GILLAM-FEi US4G. Synchronisation Supply Unit Network Clock Distributor. for PDH & SDH networks PRODUCT SPECIFICATIONS

GILLAM-FEi US4G. Synchronisation Supply Unit Network Clock Distributor. for PDH & SDH networks PRODUCT SPECIFICATIONS Synchronisation Supply Unit Network Clock Distributor for PDH & SDH networks Mont St-Martin 58 B-4000 LIEGE (BELGIUM) AQAP 110 Registered Includes ISO 9001 Doc ref. : 3031/CBe/tc rel. 7 04/05/01 Tel :

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ECI TELECOM S LQLAB 30 Hasivim Street Petah-Tikva 4959338, ISRAEL Moshe Perel Phone: 972 52-4008642 Email: Moshe.Perel@ecitele.com ELECTRICAL Valid to: June

More information

General Description. Overview. Introduction CHAPTER

General Description. Overview. Introduction CHAPTER CHAPTER This chapter contains the following sections: Overview, page - Introduction, page - Configuration Data, page -3 Management, page -5 Maintenance, page -7 Physical Characteristics, page -8 Timing,

More information

)454 ' $)')4!,,).% 3934%-3 "!3%$ /. 4(% 39.#(2/./53 $)')4!, ()%2!2#(9 &/2 53% /. /04)#!, &)"2% #!",%3 $)')4!, 3%#4)/.3!.$ $)')4!,,).

)454 ' $)')4!,,).% 3934%-3 !3%$ /. 4(% 39.#(2/./53 $)')4!, ()%2!2#(9 &/2 53% /. /04)#!, &)2% #!,%3 $)')4!, 3%#4)/.3!.$ $)')4!,,). INTERNATIONAL TELECOMMUNICATION UNION )454 ' TELECOMMUNICATION (11/94) STANDARDIZATION SECTOR OF ITU $)')4!, 3%#4)/.3!.$ $)')4!,,).% 3934%-3 $)')4!,,).% 3934%-3 "!3%$ /. 4(% 39.#(2/./53 $)')4!, ()%2!2#(9

More information

Loop-O 9300 Fiber Optical Mux

Loop-O 9300 Fiber Optical Mux 300 Fiber Optical Mux U height unit U height unit 3U height unit Features Up to 6 E links on one fiber Support Quad RS3 to 6Kbps async (Optional) Support Quad V.35 (Optional) Support 0/00M Bridge (Optional)

More information

COPYRIGHTED MATERIAL INTRODUCTION TO OPTICAL TRANSPORT CHAPTER 1

COPYRIGHTED MATERIAL INTRODUCTION TO OPTICAL TRANSPORT CHAPTER 1 CHAPTER 1 INTRODUCTION TO OPTICAL TRANSPORT This chapter covers the history of the development of SDH, SONET, and OTN. For consistency in the terminology used in this book I have included a list of conventions.

More information

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel VCL-TP, Teleprotection Equipment With Trip Counter Display Panel Data Sheet Copyright: Valiant Communications Limited. 2008-2014 1 Product Overview VCL-TP, Teleprotection Equipment is an extremely reliable

More information

FCD-155E STM-1/OC-3 Add-Drop Multiplexer

FCD-155E STM-1/OC-3 Add-Drop Multiplexer Where to buy > See the product page > Data Sheet STM-1/OC-3 add/drop multiplexer that transports LAN and traditional (TDM) traffic over SDH/SONET networks STM-1/OC-3 PDH/Ethernet add/drop multiplexer for

More information

HWATEL CATALOGUE TDM&MULTI SERVICE ACCESS. Innovation Access Solution

HWATEL CATALOGUE TDM&MULTI SERVICE ACCESS. Innovation Access Solution HWATEL CATALOGUE TDM&MULTI SERVICE ACCESS HWATEL Innovation Access Solution Index of Product 0 TDM Access Solution 1 1 DM3300 Multi Service Access Platform (MAP) 2 2 PCM30-MST Modular Multi Service Multiplexer

More information

METRO/ENTERPRISE WDM PLATFORM

METRO/ENTERPRISE WDM PLATFORM F L A S H W A V E METRO/ENTERPRISE WDM PLATFORM SCALABLE OPTICAL TRANSPORT Metro optical transport networks are increasingly defined by the unpredictable convergence of voice, data and video technologies.

More information

HX9400-R SDH STM1/STM4 - ADM/TM CONCENTRATION NODE

HX9400-R SDH STM1/STM4 - ADM/TM CONCENTRATION NODE Version 1.7 March 07 HX9400-R SDH STM1/STM4 - ADM/TM CONCENTRATION NODE C ONCENTRATION OF STM4 AND STM1 Features 6U height, ETSI shelf STM-4 or STM-1 for the Aggregate Line TM, 2xTM, ADM, and XC SNCP/UPSR

More information

Circuits and Tunnels CHAPTER

Circuits and Tunnels CHAPTER CHAPTER 7 Circuits and Tunnels This chapter explains Cisco ONS 15600 SDH high-order circuits, data communications channel (DCC), and IP-encapsulated tunnels. To provision circuits and tunnels, refer to

More information

Backbone network technologies. T Jouni Karvo, Timo Kiravuo

Backbone network technologies. T Jouni Karvo, Timo Kiravuo Backbone network technologies T-110.300 Jouni Karvo, Timo Kiravuo Backbone network technologies This lecture tells about landline backbone networks After this lecture, you should know WDM, PDH, SDH and

More information

Electromagnetic Spectrum

Electromagnetic Spectrum Electromagnetic Spectrum PCS FMRadi o/ TV Short wave Radi o AM Broadcast Ul trasoni c Soni c Vi si ble Li ght Infrared Li ght Ul travi ol et X- Rays Frequency 1 khz 1 M Hz 1 G Hz 1 THz 1 Y Hz 1 ZHz Wavelength

More information

Alcatel-Lucent 1675 LambdaUnite MultiService Switch

Alcatel-Lucent 1675 LambdaUnite MultiService Switch Alcatel-Lucent 1675 LambdaUnite MultiService Switch Versatile switching platform designed to meet today s network requirements and to drive future network trends LambdaUnite MultiService Switch (MSS) is

More information

Optimux-1032, Optimux-1025

Optimux-1032, Optimux-1025 Where to buy > Product page > Data Sheet Optimux-1032, Optimux-1025 Fiber Optic Multiplexer for 16 E1/T1 and Gigabit Ethernet Multiplexes up to 16 E1/T1 with up to 3x10/100/1000 user Ethernet traffic over

More information

RC702-FX Ethernet over SDH User Manual

RC702-FX Ethernet over SDH User Manual RC702-FX Ethernet over SDH User Manual Raisecom Technology Co., Ltd 1. Caution Please carefully read the following precautions before installing and deploying RC702-FX equipment, and operate strictly according

More information

BG-30B/E. Scaleable Optical Service Access Platform. BroadGate. Transport Networking Division. experience

BG-30B/E. Scaleable Optical Service Access Platform. BroadGate. Transport Networking Division. experience P r o d u c t N o t e BroadGate BG-30B/E Scaleable Optical Service Access Platform Springboard solution suitable for all metro and cellular network hubs Revenue generating tiered configurable service offering,

More information

Alcatel-Lucent 1353 Litespan Management System (LMS) Simplifying the Management of the Access Network

Alcatel-Lucent 1353 Litespan Management System (LMS) Simplifying the Management of the Access Network Alcatel-Lucent 1353 Litespan Management System (LMS) Simplifying the Management of the Access Network The Alcatel-Lucent 1353 Litespan Management System (LMS) is the management component of the Litespan

More information

FIBER CABLE FAULT MANAGEMENT SYSTEM

FIBER CABLE FAULT MANAGEMENT SYSTEM http:// FIBER CABLE FAULT MANAGEMENT SYSTEM Sanjeev Kumar 1, Prof. Y C Bhatt 2 1 Asst. Professor, AIACT&R, Delhi (India) 2 Director JNIT, Jaipur (India) ABSTRACT The cabling of fiber optics early adopters

More information