FUJITSU PCI Fibre Channel Update2. Update Information. for Solaris (TM) Operating Environment -
|
|
- Sharlene Smith
- 5 years ago
- Views:
Transcription
1 FUJITSU PCI Fibre Channel Update2 Update Information for Solaris (TM) Operating Environment -
2 Contents Chapter 1 New Feature...1 Chapter 2 Modification...3 i
3 ii
4 Chapter 1 New Feature The following table 1.1 defines new features added to the software of the previous version levels. [Table 1.1] Number Version Level New Feature Name Solaris 7 support 2 GP7000F model 1000, 2000 support Description Drivers that works on the 64-bit kernel of Solaris 7 are added. Driver supports the High-Reliability driver I/F of FUJITSU GP7000F model 1000, Solaris 8 support Driver supports Solaris Fabric Support Driver supports Fabric. Only class 3 is supported. 5 Function for clustered system of hot device replacement support 6 Dynamic Reconfiugration support Driver supports the function to execute the exchange of the fibre channel device to all nodes of the clustered system. Supported of Dynamic Reconfiguration for GP7000F M1000/2000 and PRIMEPOWER 800/1000/2000(*1). (*1)Please confirm the shipment time of Solaris8(for PRIMEPOWER 800/1000/2000) to sales in charge of our company. 7 Fibre Channel Tape support Driver supports Fibre channel Tape equipment ( ) Update1 Update2 1Gbps/2Gbps Fibre Channel card(pw008fc2u or PW008FC2X) support Command for hot target device addition supported HBAAPI. Support HBAAPI Support. Solaris 9 9/04 OE support 1Gbps/2Gbps Fibre Channel card(pw008fc3u or PW008FC3X) support Driver supports 2Gbps Fibre channel card(pw008fc2u or PW008FC2X). You can add target device dynamically without DR. Renewal of installer for Solaris 9 9/04 OE. support.. Driver supports new 2Gbps Fibre channel card(pw008fc3u or PW008FC3X). 1
5 2
6 Chapter 2 Modification Bugs found in the software of the previous version levels are fixed. See the following table for the details of the bugs and P-number. [Table ] Number Version Level P-number 1.1 ( ) PE12729 Bug Timeout message from the disk driver might be displayed under the following 1. Using GP7B8FC1U as a HBA(Host Bus Adapter), and 2. Connecting more than 2 target devices to the adapter, and 3. Issueing more than 255 I/O commands to each target. 1.1 ( ) PE12743 Panic might occur under the following 1. When using RAID device via Fibre Channel(GP7B8FC1U). 1.1 ( ) PE ( ) PE ( ) PE12948 Panic which displays the message "mutex_exit:not owner" might occur under the following 1. Connecting RAID(or disk) devices other than GP-DxxF2x or GR700 series. Fibre Channel adapters other than GP7B8FC1U might not be able to coexist with GP7B8FC1U. 1. When you installed FUJITSU PCI Fibre Channel 1.0 Chgfcctl command displays the message; "chgfcctl: specified disk is used by other process.", and aborts under the following 1. When you use the Multipath disk control software. A panic whose message is "recursive mutex_enter" occures under the following 1. Using GP7B8FC1U Fibre Channel adapter and it receives one of the following extended link service command PE RES(Read Exchange Status Block) - RSS(Read Sequence Status Block) - RTV(Read Timeout Value) - RLS(Read Link Status Block) - ECHO(Echo) - TEST(Test) 7 ( ) P A panic occures under the following 1. When I/O completion and abort request collides ( ) PE13138 A panic with "assertion failed:!(path->path_wait_flag & WAIT_FCPH_CALBACK)" occurs under the following 1. You are using RAID heavily, and 2. When you disconnect the optical fibre from a GP7B8FC1U or a RAID. ( ) PE13421 A garbage is contained in DF_CTL field under the following 1. When GP7B8FC1U receives LOGO command and responds to this command. ( ) PE13428 A panic at "fcph_rem_que+0x10" occurs uner the following 1. When you use GP7B8FC1U. Especially, when you disconnect the optical fibre. ( ) PE13482 A I/O won't complete and a message "scsi command abort(abts) timeout" is logged to /var/adm/messages. 1. When you use GP7B8FC1U, and 2. When you disconnect the optical fiber while I/O is running. You might see a message "no memory for disk label" under the following ( ) PE When you use GP7B8FC1U, and 2. When you connect a RAID that has many logical units. ( ) PE14218 You can't get a panic dump under the following 1. When you are going to dump to a device that is connected via GP7B8FC1U. 14 PE14223 A panic with "bad mutex" will occur under the following 3
7 ( ) 1. When you use GP7B8FC1U, and 2. Extended Link service transmission failure and its timeout collides..1 ( ) P ( ) PE ( ) PE14733 ( ) PG00668 ( ) PG00671 ( ) ( ) PG00817 ( ) PG00872 ( ) PG00942 ( ) PG00943 A message "unix: warning: interrupt level x not serviced." is sometimes displayed under the following 1. When you use GP7B8FC1U, and 2. I/O load is very heavy. A panic with "assertion failed: fcph_exp->fc_ex_mng.reserve[0]" might occur under the following 1. When you use GP7B8FC1U, and 2. Memory lack occurs when scsi_init_pkt() is called. A message "unix: warning: interrupt level 4 not serviced." may be displayed for the following conditions: 1. with the use of GP7B8FC1U, and 2. the SCSI Reset command is issued in command processing by SCSI target driver. A message "received short frame", "link down" may be displayed for the following conditions: 1. connected Arbitrated loop topology, and 2. I/O load is very heavy. A message "scsi command timeout" may be displayed for the following conditions: 1. When two or more GP7B8FC1U access to one RAID controller, and 2. I/O load is very heavy, and 3. response speed of the RAID controller declines for a heavy load. PG00672 Added the function to emulate the behavior when disabled Auto request sence. Panic might occur under the following 1. many logical unit is defined, and 2. when hard error and link error occur. It cannot detected the target device for the following 1. connected with fabric, and 2. when you set domain ID of fabric(fibre channel switch) to 128 or more. Panic might occur under the following 1. Two target devices or more are connected with GP7B8FC1U I/O commands or more are sent from GP7B8FC1U at the same time. 3. when it causes Linkdown by the cable pulling out etc. I/O commands might kept stopping under the following 1. Two target devices or more are connected with GP7B8FC1U I/O commands or more are sent from GP7B8FC1U at the same time. 3. when it causes Linkdown by the cable pulling out etc. ( ) P GP7B8FC1U can't find some LUs of the RAID system under the following 1. If boot device is a non-scsi one(ssa, IDE etc.) 26 PG ( ) PG02332 ( ) PG02522 ( ) PG02523 I/O commands might kept stoppoing under the following 1. A number of logical unit are defined. 2. When scsi_reset(9f) is executed all of them. The port property definition for instance 0, 9, 19, in /kernel/drv/fjpfca.conf dosen't work. Such adapter works as auto negotiation mode. 1. Adapter's instance 0, 9, 10, 19, 's port property is defined. The targets that target id is 15(0xf),31(0x1f),47(0x2f)... are not detected by GP7B8FC1U. 1. If "Disable device probing Option"(SN200's configuration option) is set "0". The host might be hung under the following 1. GP7B8FC1U detects Extended Link Service exchange timeout,then driver frees Fibre Channel resouces ( i.e. exchange id, sequence id ) after R_A_TOV past. 2. If GP7B8FC1U sends an exchange to name server of SN200 at the same time. ( ) PG03274 I/O commands might kept stoppoing under the following 1. The disk Array has so many LUs. 4
8 When disk array responses a NOT READY sense(2/4/1). ( ) PG03276 Time for path fail over is too long under the following 1. A persistent link down condition is occur. ( ) PG03491 ( ) P ( ) P ( ) P ( ) A fiber channel link is not up under the following 1. GP7B8FC1U connects with SN SN200's power switch off and on with fibre channel cable puluged in. A panic whose message is "mutex_enter: bad_mutex" occur under the following 1. When LU liberation processing. A panic whose message is "mutex_enter: bad_mutex" occur under the following 1. When LU liberation processing was done. A panic with Illegal area access will occur under the following 1. By point-to-point(nport) connection, not to go by way of a fiber channel switch, and 2. When connected directly with a disk array device / FC tape device. PG04429 When bootstraps, some LUs might not be recognized by GP7B8FC1U. ( ) PG04454 When you disconnect system board, panic might be happen with the messages "mutex enter: bad mutex" ) ( ) PG04857 ( ) PG05497 When linkdown occur frequently in Arbitrated loop topology, GP7B8FC1U might not detect targets. PG04859 Supports the lus driver of Legato's Networker If driver can't recognize target for a few minutes and scsi_reset(9f) command execute it's device, but open(3c) system call to it's target must be succeeded before target has been lost, system might be hung.. ( ) PG05863 When reconfigure boot straps( i.e. boot -r ). panic might be happen with the messages "assertion failed: failover_timer_inactive(port)". ( ) PG05864 When GP7B8FC1U connected with SN200 and linkdown occur frequently, panic might be happen. ( ) ( ) ( ) ( ) ( ) PG05865 If scsi_abort(9f) call from upper layer driver, panic might be happen. PG06484 Even if the target disappears without RSCN, improve elapsed time of path fail over. PG06485 E_D_TOV is changed to 2000ms in private loop environment. PG07155 When ABTS is received to I/O under execution, I/O may not return. PG07223 Freezing Timeout value changed to 20sec. ( ) PG07373 When the information on the target which does not exist in NameServer remains, I/O to the target may not return. ( ) PG07506 If I/O command executes at the same time scsi_reset(9f) return to thr ULP driver(e.g sd), I/O to the target may not return. 50 PG07556 When LOGO received from target, stop transmit ABTS concerned with active exchange. 5
9 ( ) ( ) PG10199 When GP7B8FC1U receives FCP_XFER_RDY frame with burst_len field error,driver may detect this error quickly. ( ) PG11072 Driver supports RSCN(Remote node Status Change Notification) address format 3. ( ) PG11073 When boot straps, Added the function to disable to display A message "Link Failure Cable Probrem?". ( ) PG11074 ( ) PG11080 ( ) PG11802 Panic might occur under the following 1. connected with fabric, and 2. linkdown occur when GP7B8FC1U send fibre channel frames to fabric's Name server. I/O commands might end immidiately in error under the following 1. scsi_reset(9f) is executed, and 2. linkdown occur. Driver can't be recognized target which was hot device replacement before in under the following 1. You use PRIMEPOWER M1000, M2000, and 2. You bind the target-id and WWN(as fcp-bind-target in fjpfca.conf), and 3. You execute hot device replacement of fibre channel device(chgfcctl or clchgfc), and 4. System is not rebooting, and 5. You disconnect system board with GP7B8FC1, and connect that. ( ) PG11803 If you execute hot device replacement of fibre channel device in I/O under execution, panic might be happen. ( ) PG11811 Installing driver is failed with messages "System configuration files modified but fjpfca driver not loaded or attached.", because of DMA attribute setting failure. ( ) PG11910 ( ) PG13393 ( ) PG14623 A message "panic[cpuxx]/thread=xxxxxxxx: assertion failed: failover_timer_inactive(port), file: fcp_port.c, line: XXX" is displayed and panic occur under the following condition. 1. Within 30 second from the target was disappeared because of failure. 2. If you execute hot deveice replacement of fibre channel device. A panic occur under the following 1. When an adapter reset command (fc_adm-r fjpfcax) is executed during access to disk array device and tape device, and 2. When a PCI system error occurs. I/O may remain suspended and I/O processing hung-up may occur under the following 1. The disk array device that target ID is more than 16 exists, and 2. When I/O access is received during poll processing of reset etc. ( ) PG15531 Display a message of scsi command (abts) timeout, and there is the case that I/O does not return to. ( ) PG15533 A panic with Illegal area access will occur under the following 1. In detach processing movement of a driver. ( ) PG15534 ( ) PG15536 ( ) PG15537 I/O in execution can be continued under the following 1. Connected to a fiber channel switch, and 2. When divided zone during I/O execution. Added the function which is not accessed by judging an I/O device to be unusual and changing into a blockade state When a demand of inaccurate data transmission length is received among I/O A panic whose message is "assersion fail:!(fcph_seqp->status & FCPH_SEQ_STATUS_ABTS_SR)" occur under the following 1. Between I/O, received ABTS. 6
10 ( ) ( ) ( ) PG15578 PG15576 It supports I/O published with time-out un-specifying. PG15577 Do not reply to PDISC extended link service normally. A panic which illegal DMA address is assigned under the following 1. When it is used in Solaris 8 where SunOS 5.8 kernel update patch or subsequent ones is not applied. ( ) PG15707 Boot time can delay under the following 1. When set port property in "nport" and was connected to FC-HUB. ( ) PG16308 ( ) ( ) PG17136 ( ) PG17279 A panic occur under the following 1. Transmission channel abnormality occurs, and 2. When data were canceled. PG16309 Some device recognition can fail in boot. In 2G fiber channel card (PW008FC2) system panic or a system may incorrect-operate under the following 1. connect the disk array device / tape device which can communicate with 2Gbps, and 2. When the receiving buffer address specified by upper software is odd number byte boundary. Recognition processing of a target device under the following 1. When a state change notice for a target device occurred from FC-SWITCH continually. ( ) PG17280 In boot, succeed in recognition of a target device, but there can be a thing failing in recognition processing of LU ( ) PG17389 ( ) PG18200 Hard interrupt continues being notified of and can reach system hang under the following 1. When adapter reset processing was done. A panic by the or illegal area access how I/O does not return to can occur under the following 1. Connected to a fiber channel switch, and 2. When let a cable. ( ) PG18201 Don't Link Up in host boot under the following 1. When connected to a fiber channel switch. ( ) PG18812 Improve to write throughput of the case that used PW008FC2 with PRIMEPOWER1000/2000. ( ) PG19399 ( ) PG19708 ( ) PG20045 ( ) PG20440 New I/O does not return under the following 1. It is executed SCSI reset or SCSI abort, and 2. When new I/O was published during the processing. A panic occur under the following 1. Use fiber channel card (GP7B8FC1), and 2. When the state by a transmission channel obstacle normally, and do not link up continues it after boot for ten minutes. A panic with Illegal area access will occur under the following 1. In PW008FC2 use, and 2. In publication of mode sense command. Recognition processing can fail under the following 1. When, in system boot, LU recognition processing was executed just after initialization processing of a driver. ( ) PG22343 Disconnect processing of PHP/DR under the following 1. When disconnect fiber channel card (PW008FC2,GP7B8FC1) by PHP/DR. 7
11 85 86 ( ) PG22344 ( ) PG22431 A panic whose message is "mutex_enter: bad_mutex" occur under the following 1. When disconnect fiber channel card (PW008FC2,GP7B8FC1) by PHP/DR. A panic whose message is "Bus Timeout Event detected.." occur under the following 1. When disconnect fiber channel card (PW008FC2) by PHP/DR. In 2G fiber channel card (PW008FC2) system panic or a system may incorrect-operate under the following ( ) PG23323 ( ) PG23170 It supports HBAAPI. 1. connect the disk array device / tape device which can communicate with 2Gbps, and 2. When the receiving buffer address specified by upper software is odd number byte boundary. 3. When more data transmission to I/O is completed almost simultaneous. ( ) PG25029 a system panic and a hang phenomenon occur under the following 1. When scsi_abort(9f) was published in large quantities. ( ) PG25030 ( ) PG25031 Repeat link up and down with message is "Freezing Timeout.." display under the following 1. When transmission channel abnormality occurred. A system panic whose message is "assertion failed: (ex->cntl & FC_EX_CTL_IGNORE_TX) == 0" occur under the following 1. When transmission channel abnormality occurred. ( ) PG25163 I/O in execution can do hangup under the following 1. In the hard error occurrence. ( ) PG27875 Inprove to the return time of individual I/O when the clear demand of the I/O cue by scsi_abort (9F) carries out a timeout ( ) PG27876 Although there are no abnormalities in operation, the message of "WARNING interrupt level 6 not serviced" may be displayed under the following 1. At the time of command issue of pole, such as scsi_reset (9F). ( ) PG28745 Improve to the Clexecd is point which hangs-up and becomes heavy load in PCL and Safe cluster function standstill. ( ) ( ) PG30442 ( PG30441 It supports untagged-qing. PG32322 A system panic whose message is "assertion failed: dest->addr_info & FC_PORT_PORT_NAME, file: fcp_arp.c, line: XXX" occur under the following 1. In transmission channel abnormality. panic occurs on a system that LMF installed ( ) PG32706 Dynamic Reconfiguration/PCI Hot Plug might be failed during high performance I/O execution. ( ) ( ) ( ) PG32322 When disconnecting card(pw008fc2,gp7b8fc1) at DR/PHP, panic might be occur. PG32076 FcpGetTargetMapping HBAAPI function returns wrong information for FC Tape device. PG35915 Driver supports new 2Gbps Fibre channel card(pw008fc3u or PW008FC3X). 8
12 103 ( ) PG36017 A panic may occur when a system receive a fibre channel frame under shortage of system memory. 9
13 10
FUJITSU PCI Fibre Channel Update1. Guide. for Solaris (TM) Operating Environment -
FUJITSU PCI Fibre Channel 2.2.1 Update1 Guide for Solaris (TM) Operating Environment - Contents Chapter 1 Overview...1 1.1 Function Overview... 1 1.2 Hardware Support... 2 1.3 Related Software... 5 Chapter
More informationINSTALLATION GUIDE. FUJITSU PCI Fibre Channel 4.0 Update2
Manual code: C120-E392-03EN INSTALLATION GUIDE FUJITSU PCI Fibre Channel 4.0 Update2 for Solaris Operating System The Customer acknowledges and agrees that the Product is designed, developed and manufactured
More informationServer Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationBuilding a High Availability System on Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Servers (Overview)
Building a High Availability System on Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Servers (Overview) September 2017 Rev 3.0 Fujitsu LIMITED Contents Introduction 1. Model Case of HA System 2. Example
More informationServer Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationBuilding a High Availability System on Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Servers (Overview)
Building a High Availability System on Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Servers (Overview) May. 2017 Rev 2.1 Fujitsu LIMITED Contents Introduction 1. Model Case of HA System 2. Example of HA
More informationFUJITSU PCI Gigabit Ethernet 4.1 Update2 / 5.0 for Oracle Solaris. Update Information. Solaris. C120-E613-04ENZ0(A) October 2011.
FUJITSU PCI Gigabit Ethernet 4.1 Update2 / 5.0 for Oracle Solaris Update Information Solaris C120-E613-04ENZ0(A) October 2011 SPARC Enterprise Preface Purpose This manual describes the functions and Bug
More informationClass 3 Error Detection and Recovery for Sequential Access Devices Preliminary ANSI T10 Working Document R22
Class 3 Error Detection and Recovery for Sequential Access Devices Preliminary ANSI T10 Working Document 97-189R22 Scope Problems exist in PLDA in detecting and correcting error conditions on sequential
More informationFibre Channel card Users Guide
C122-E012-19EN PRIMEQUEST Fibre Channel card Users Guide 2G Fibre Channel PCI-X card (MC-08FC11/ MC-08FC71) 4G Fibre Channel PCI-X card (MC-08FC31/ MC-08FC41) 4G Fibre Channel PCI-express card (MC-08FC51/
More informationEnhanced Support Facility User s Guide For Dynamic Reconfiguration (PRIMEPOWER)
C120-E115-09ENZ2(A) Enhanced Support Facility User s Guide For Dynamic Reconfiguration (PRIMEPOWER) Preface Preface Purpose This manual provides an overview of each of the functions of the Dynamic Reconfiguration
More informationExam : S Title : Snia Storage Network Management/Administration. Version : Demo
Exam : S10-200 Title : Snia Storage Network Management/Administration Version : Demo 1. A SAN architect is asked to implement an infrastructure for a production and a test environment using Fibre Channel
More informationThe Contents and Structure of this Manual. This document is composed of the following three chapters.
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationS SNIA Storage Networking Management & Administration
S10 201 SNIA Storage Networking Management & Administration Version 23.3 Topic 1, Volume A QUESTION NO: 1 Which two (2) are advantages of ISL over subscription? (Choose two.) A. efficient ISL bandwidth
More informationETERNUS Multipath Driver (Oracle Solaris Version) Installation Information
ETERNUS Multipath Driver (Oracle Solaris Version) Installation Information September 2011 Contents Supported OS 1 Restrictions and Resolution schedule (the driver for Solaris 10 OS and Solaris 9 OS) 1
More informationThe Contents and Structure of this Manual. This document is composed of the following four chapters and an appendix.
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationDynamic Reconfiguration User s Guide 2.4
Dynamic Reconfiguration User s Guide 2.4 Preface Purpose This manual describes the Dynamic Reconfiguration (DR) feature, which enables you to logically attach and detach system boards without shutting
More informationETERNUS SF AdvancedCopy Manager Glossary
ETERNUS SF AdvancedCopy Manager 14.1 Glossary J2X1-7455-02ENZ0(00) January 2010 Preface Purpose This manual describes the terminology used in the ETERNUS SF AdvancedCopy Manager manuals. Intended Readers
More informationMac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide
Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide Part number: 5697-0025 Third edition: July 2009 Legal and notice information Copyright
More informationFC-FCoE Adapter Inbox Driver Update for Linux Kernel 2.6.x. Table of Contents
FC-FCoE Adapter Inbox Driver Update for Linux Kernel 2.6.x QLogic Corporation. All rights reserved. Table of Contents 1. Version 2. Changes 3. Bug Fixes 4. Known Issues 5. Additional Information 6. History
More informationFabric Services. Tom Clark Director, Technical Marketing
Fabric Services Tom Clark Director, Technical Marketing April 2000 Introduction A fabric is one or more Fibre Channel switches connected together as a network. Typically, fabrics are used to build storage
More informationPRIMECLUSTER DR/PCI Hot Plug User s Guide
PRIMECLUSTER DR/PCI Hot Plug User s Guide - SPARC Solaris - Version 4.2 November, 2003 Introduction This manual describes how to use the Dynamic Reconfiguration (DR) function and the PCI Hot Plug function
More informationThe Contents and Structure of this Manual. This document is composed of the following three chapters and an appendix.
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationStorage Area Networks SAN. Shane Healy
Storage Area Networks SAN Shane Healy Objective/Agenda Provide a basic overview of what Storage Area Networks (SAN) are, what the constituent components are, and how these components fit together to deliver
More informationServer Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationFibre Channel Gateway Overview
CHAPTER 5 This chapter describes the Fibre Channel gateways and includes the following sections: About the Fibre Channel Gateway, page 5-1 Terms and Concepts, page 5-2 Cisco SFS 3500 Fibre Channel Gateway
More informationChapter 12: Mass-Storage
Chapter 12: Mass-Storage Systems Chapter 12: Mass-Storage Systems Revised 2010. Tao Yang Overview of Mass Storage Structure Disk Structure Disk Attachment Disk Scheduling Disk Management Swap-Space Management
More informationVTrak E5000/EFA5310 Series
VTrak E5000/EFA5310 Series E5000/EFA5310 SR3 Release Notes FW 11.05.0000.00 BIOS 15.27.0000.07 Note: The E5000/EFA5310 SR3 Release is a combined Firmware and BIOS Release that requires flashing both images
More informationTo: T10 Membership T10/97-184R4 Subject: Use of Class 2 for Fibre Channel Tapes From: Date: 23-Oct-1997
To: T10 Membership T10/97-184R4 Subject: Use of Class 2 for Fibre Channel Tapes From: Date: 23-Oct-1997 This paper describes the use of the Fibre Channel Class 2 protocol
More informationCHAPTER 12 AND 13 - MASS-STORAGE STRUCTURE & I/O- SYSTEMS
CHAPTER 12 AND 13 - MASS-STORAGE STRUCTURE & I/O- SYSTEMS OBJECTIVES Describe physical structure of secondary storage devices and its effects on the uses of the devices Explain the performance char. of
More informationChapter 13: I/O Systems. Operating System Concepts 9 th Edition
Chapter 13: I/O Systems Silberschatz, Galvin and Gagne 2013 Chapter 13: I/O Systems Overview I/O Hardware Application I/O Interface Kernel I/O Subsystem Transforming I/O Requests to Hardware Operations
More informationChapter 13: I/O Systems
Chapter 13: I/O Systems Silberschatz, Galvin and Gagne 2013! Chapter 13: I/O Systems I/O Hardware" Application I/O Interface" Kernel I/O Subsystem" Transforming I/O Requests to Hardware Operations" STREAMS"
More informationChapter 13: I/O Systems
Chapter 13: I/O Systems DM510-14 Chapter 13: I/O Systems I/O Hardware Application I/O Interface Kernel I/O Subsystem Transforming I/O Requests to Hardware Operations STREAMS Performance 13.2 Objectives
More informationHigh-reliability, High-availability Cluster System Supporting Cloud Environment
High-reliability, High-availability Cluster Supporting Cloud Environment Seishiro Hamanaka Kunikazu Takahashi Fujitsu is offering FUJITSU Software, a high-reliability software platform that supports the
More informationSnia S Storage Networking Management/Administration.
Snia S10-200 Storage Networking Management/Administration http://killexams.com/exam-detail/s10-200 QUESTION: 85 What are two advantages of over-subscription? (Choose two.) A. saves on ISL links B. decreases
More informationChapter 12: I/O Systems
Chapter 12: I/O Systems Chapter 12: I/O Systems I/O Hardware! Application I/O Interface! Kernel I/O Subsystem! Transforming I/O Requests to Hardware Operations! STREAMS! Performance! Silberschatz, Galvin
More informationChapter 13: I/O Systems
Chapter 13: I/O Systems Chapter 13: I/O Systems I/O Hardware Application I/O Interface Kernel I/O Subsystem Transforming I/O Requests to Hardware Operations STREAMS Performance Silberschatz, Galvin and
More informationChapter 12: I/O Systems. Operating System Concepts Essentials 8 th Edition
Chapter 12: I/O Systems Silberschatz, Galvin and Gagne 2011 Chapter 12: I/O Systems I/O Hardware Application I/O Interface Kernel I/O Subsystem Transforming I/O Requests to Hardware Operations STREAMS
More informationChapter 10: Mass-Storage Systems. Operating System Concepts 9 th Edition
Chapter 10: Mass-Storage Systems Silberschatz, Galvin and Gagne 2013 Chapter 10: Mass-Storage Systems Overview of Mass Storage Structure Disk Structure Disk Attachment Disk Scheduling Disk Management Swap-Space
More informationEastern Mediterranean University School of Computing and Technology INPUT / OUTPUT
Eastern Mediterranean University School of Computing and Technology ITEC255 Computer Organization & Architecture INPUT / OUTPUT Introduction Computer system s I/O architecture is its interface to outside
More informationATTO Celerity Fibre Channel Host Adapter Troubleshooting Guide for Mac OS X
ATTO Celerity Fibre Channel Host Adapter Troubleshooting Guide for Mac OS X 1 5 5 C r o s s P o i n t P a r k w a y A m h e r s t, N Y 1 4 0 6 8 P. 7 1 6. 6 9 1. 1 9 9 9 F. 7 1 6. 6 9 1. 9 3 5 3 w w w.
More informationExpressSAS Host Adapter 6Gb v2.30 Windows
Product Release Notes ExpressSAS Host Adapter 6Gb v2.30 Windows 1. General Release Information These product release notes define the new features, changes, known issues and release details that apply
More informationQLogic QLx2xx/QLA22xx/QLx23xx/QLx24xx Fibre Channel Linux Driver for Kernel 2.4. Table of Contents
QLogic QLx2xx/QLA22xx/QLx23xx/QLx24xx Fibre Channel Linux Driver for Kernel 2.4 Version: 7.07.05 OS Support : HBA Support: Red Hat RHEL 3 AS - Update 7 and Update 6 (IA32, EM64T, AMD64, IA64) Novell SLES
More informationOrganisasi Sistem Komputer
LOGO Organisasi Sistem Komputer OSK 5 Input Output 1 1 PT. Elektronika FT UNY Input/Output Problems Wide variety of peripherals Delivering different amounts of data At different speeds In different formats
More informationChapter 10: Mass-Storage Systems
Chapter 10: Mass-Storage Systems Silberschatz, Galvin and Gagne 2013 Chapter 10: Mass-Storage Systems Overview of Mass Storage Structure Disk Structure Disk Attachment Disk Scheduling Disk Management Swap-Space
More informationCluster Configuration Design Guide (Linux/PRIMECLUSTER)
C122-A007-04EN PRIMEQUEST 1000 Series Cluster Configuration Design Guide (Linux/PRIMECLUSTER) FUJITSU LIMITED Preface This manual describes the network and shared I/O unit information and configuration
More informationThe Contents and Structure of this Manual. This document is composed of the following 12 chapters.
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationIBM FlashSystem 900. Firmware Version Release Notes
IBM FlashSystem 900 Firmware Version 1.2.1.5 Release Notes June 16, 2015 Contents 1.0 Applicable systems... 2 2.0 Product resources... 2 3.0 Bug severity legend... 2 4.0 Latest changes... 2 4.1 Issue fixed...2
More informationATTO Celerity FC Troubleshooting Guide for Windows
ATTO Celerity FC Troubleshooting Guide for Windows This document describes troubleshooting techniques that can be used to identify and resolve issues associated with the ATTO Celerity Fibre Channel host
More informationETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationAppendix A Fast!UTIL
Appendix A Fast!UTIL This appendix is part of the QLogic Corporation manual Hardware Installation Guide for the QLA1xxx Boards (PC0056105-00 E). The QLogic disclaimer and copyright notices for this document
More informationConnectivity. Module 2.2. Copyright 2006 EMC Corporation. Do not Copy - All Rights Reserved. Connectivity - 1
Connectivity Module 2.2 2006 EMC Corporation. All rights reserved. Connectivity - 1 Connectivity Upon completion of this module, you will be able to: Describe the physical components of a networked storage
More informationMAA3182SC, MAB3091SC INTELLIGENT DISK DRIVES OEM MANUAL
MAA3182SC, MAB3091SC INTELLIGENT DISK DRIVES OEM MANUAL SCSI LOGICAL INTERFACE SPECIFICATIONS C141-E039-01EN FOR SAFE OPERATION Handling of This manual This manual contains important information for using
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO/IEC 14165-141 First edition 2001-06 Information technology Fibre Channel Part 141: (FC-FG) Reference number ISO/IEC 14165-141:2001(E) INTERNATIONAL STANDARD ISO/IEC 14165-141
More informationDell PowerEdge 6 Gbps SAS HBA and Internal Tape Adapter. User s Guide
Dell PowerEdge 6 Gbps SAS HBA and Internal Tape Adapter User s Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:
More informationThe Contents and Structure of this Manual. This document is composed of the following 12 chapters.
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationRelease Definitions for SDMS 4.7 CD-ROM Software
Release Definitions for SDMS 4.7 CD-ROM Software LSI Logic distributes an SDMS Software Device Drivers and Utilities CD- ROM that contains SDMS device drivers for specific operating systems. The SDMS 4.7
More informationRAID-01 (ciss) B Mass Storage Driver Release Notes
RAID-01 (ciss) B.11.31.1705 Mass Storage Driver Release Notes HP-UX 11i v3 Abstract This document contains specific information that is intended for users of this HPE product. Part Number: Published:
More informationIBM TotalStorage SAN Switch F08
Entry workgroup fabric connectivity, scalable with core/edge fabrics to large enterprise SANs IBM TotalStorage SAN Switch F08 Entry fabric switch with high performance and advanced fabric services Highlights
More informationSymmetrix Fibre Channel with Qlogic Host Bus Adapters in the SCO UnixWare 7 Environment
Symmetrix Fibre Channel with Qlogic Host Bus Adapters in the SCO UnixWare 7 Environment November 2000 Copyright 2000 EMC Corporation. All rights reserved. No part of this publication may be reproduced
More informationUNIT-7. Overview of Mass Storage Structure
Overview of Mass Storage Structure UNIT-7 Magnetic disks provide bulk of secondary storage of modern computers Drives rotate at 60 to 200 times per second Transfer rate is rate at which data flow between
More informationHitachi Freedom Storage Lightning 9900 V Series Windows NT Configuration Guide
Hitachi Freedom Storage Lightning 9900 V Series Windows NT Configuration Guide 2002 Hitachi Data Systems Corporation, ALL RIGHTS RESERVED Notice: No part of this publication may be reproduced or transmitted
More informationI/O Systems. Amir H. Payberah. Amirkabir University of Technology (Tehran Polytechnic)
I/O Systems Amir H. Payberah amir@sics.se Amirkabir University of Technology (Tehran Polytechnic) Amir H. Payberah (Tehran Polytechnic) I/O Systems 1393/9/15 1 / 57 Motivation Amir H. Payberah (Tehran
More information操作系统概念 13. I/O Systems
OPERATING SYSTEM CONCEPTS 操作系统概念 13. I/O Systems 东南大学计算机学院 Baili Zhang/ Southeast 1 Objectives 13. I/O Systems Explore the structure of an operating system s I/O subsystem Discuss the principles of I/O
More informationV. Mass Storage Systems
TDIU25: Operating Systems V. Mass Storage Systems SGG9: chapter 12 o Mass storage: Hard disks, structure, scheduling, RAID Copyright Notice: The lecture notes are mainly based on modifications of the slides
More informationInteroperability Guidelines for Non-Cisco Switches
APPENDIXA Interoperability Guidelines for Non-Cisco Switches This appendix includes information on changing interop modes and describes release-specific behavior for certain versions of Brocade, McData,
More informationComputer Systems Assignment 4: Scheduling and I/O
Autumn Term 018 Distributed Computing Computer Systems Assignment : Scheduling and I/O Assigned on: October 19, 018 1 Scheduling The following table describes tasks to be scheduled. The table contains
More informationHP StorageWorks Disk Array XP operating system configuration guide
OpenVMS HP StorageWorks Disk Array XP operating system configuration guide XP48 XP128 XP512 XP1024 XP12000 fourth edition (November 2004) part number: A5951-96132 This guide describes the requirements
More informationEXAMGOOD QUESTION & ANSWER. Accurate study guides High passing rate! Exam Good provides update free of charge in one year!
EXAMGOOD QUESTION & ANSWER Exam Good provides update free of charge in one year! Accurate study guides High passing rate! http://www.examgood.com Exam : NS0-210 Title : Network Appliance FAS900 Pre-Sales
More informationQuestion: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects?
Volume: 327 Questions Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects? A. primary first, and then secondary
More informationGeneric Model of I/O Module Interface to CPU and Memory Interface to one or more peripherals
William Stallings Computer Organization and Architecture 7 th Edition Chapter 7 Input/Output Input/Output Problems Wide variety of peripherals Delivering different amounts of data At different speeds In
More informationEIDE, ATA, SATA, USB,
Magnetic disks provide bulk of secondary storage of modern computers! Drives rotate at 60 to 200 times per second! Transfer rate is rate at which data flow between drive and computer! Positioning time
More informationTroubleshooting. Resetting the System. Problems Following Initial System Installation. First Steps Checklist CHAPTER
CHAPTER 6 This chapter helps you identify and solve problems that might occur while you are using the Cisco CDE110. If you are unable to resolve your server problems on your own, contact Cisco Technical
More informationVTrak E5000/EFA5310 Series
VTrak E5000/EFA5310 Series E5000/EFA5310 SR4 Release Notes FW 11.07.0000.01 1. Release Summary VTrak firmware version 11.07.0000.01 is a service release update to the FCS, PR1, SR1, SR2 SR3 and SR3.1 releases.
More informationTunables for the Sun StorEdge TM SAN Foundation Suite: Optimizing for Performance and Failover
Tunables for the Sun StorEdge TM SAN Foundation Suite: Optimizing for Performance and Failover Chris Wood, Sajid Zia, and Dennis Kleppen June 2007 Sun Microsystems, Inc. Abstract: This article describes
More informationProduct Release Notes
Product Release Notes ExpressSAS 6Gb RAID Release v3.76 - Mac OS X 1. General Release Information These product release notes define the new features, changes, known issues and release details that apply
More informationFUJITSU 10Gigabit Ethernet 1.0 for Solaris TM Operating System. User's Guide. C120-E585-01EN April SPARC Enterprise
FUJITSU 10Gigabit Ethernet 1.0 for Solaris TM Operating System User's Guide C120-E585-01EN April 2009 SPARC Enterprise For Safe Operation Handling of This Manual This manual contains important information
More informationQLogic Fibre Channel Adapter Stor Miniport Driver for Windows Server 2003/Windows XP Professional. Table of Contents
QLogic Fibre Channel Adapter Stor Miniport Driver for Windows Server 2003/Windows XP Professional This software license applies only to QLogic customers. QLogic Corporation. All rights reserved. Table
More informationC120-E087-05EN. Partition Operation Guide
C120-E087-05EN Partition Operation Guide May 2003 FOR SAFE OPERATION This manual contains important information for using this product. Read thoroughly before using the product. Use this product only
More informationFibre Channel Commands
CHAPTER 3 This chapter documents the following commands: fc srp initiator, page 3-2 fc srp initiator-wwpn, page 3-5 fc srp it, page 3-7 fc srp itl, page 3-9 fc srp lu, page 3-13 fc srp target, page 3-17
More informationEMC Fibre Channel with Emulex Host Bus Adapters in the Solaris Environment
EMC Fibre Channel with Emulex Host Bus Adapters in the Solaris Environment P/N 300-001-156 REV A11 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright
More informationStorage Area Networks: Performance and Security
Storage Area Networks: Performance and Security Presented by Matthew Packard July 27, 2003 SAN Architecture - Definition & DAS Limitations Storage Area Network (SAN) universal storage connectivity free
More informationOperating System: Chap13 I/O Systems. National Tsing-Hua University 2016, Fall Semester
Operating System: Chap13 I/O Systems National Tsing-Hua University 2016, Fall Semester Outline Overview I/O Hardware I/O Methods Kernel I/O Subsystem Performance Application Interface Operating System
More informationLecture 1 Introduction (Chapter 1 of Textbook)
Bilkent University Department of Computer Engineering CS342 Operating Systems Lecture 1 Introduction (Chapter 1 of Textbook) Dr. İbrahim Körpeoğlu http://www.cs.bilkent.edu.tr/~korpe 1 References The slides
More informationETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationStorage Area Network (SAN)
Storage Area Network (SAN) 1 Outline Shared Storage Architecture Direct Access Storage (DAS) SCSI RAID Network Attached Storage (NAS) Storage Area Network (SAN) Fiber Channel and Fiber Channel Switch 2
More informationXTCC - extended Tape Control Center
XTCC - extended Tape Control Center Product Characteristics This paper gives an introduction to a graphical, Tcl/Tk based system monitoring tool called XTCC used on peripheral systems connected to mainframes.
More informationKeywords: ASM, Fiber channel, Testing, Avionics.
Implementation of Fiber Channel Avionics Environment Anonymous Subcriber Messaging Protocol and Testing Shweta Dinnimani 1, Sree Ranjani N. Y. 2, Lakshmi T. 3 1 M. Tech. Scholar, Digital Electronics 2
More informationMK-99BDS Page 1 of 12
Preface This is a concise reference of all the recommended firmware, drivers, and utilities for the Hitachi Compute Blade 320 (CB 320). Relevant release notes for firmware versions are also included. Note:
More informationFIBRE CHANNEL TESTING FOR AVIONICS APPLICATIONS. Bill Fleissner Gary Warden
FIBRE CHANNEL TESTING FOR AVIONICS APPLICATIONS Bill Fleissner Gary Warden 2007 Fibre Channel is being implemented as an avionics communication architecture for a variety of new military aircraft and upgrades
More informationProduct Release Notes
Product Release Notes ExpressSAS 6Gb RAID Release v3.65 - Mac OS X 1. General Release Information These product release notes define the new features, changes, known issues and release details that apply
More informationInput/Output Problems. External Devices. Input/Output Module. I/O Steps. I/O Module Function Computer Architecture
168 420 Computer Architecture Chapter 6 Input/Output Input/Output Problems Wide variety of peripherals Delivering different amounts of data At different speeds In different formats All slower than CPU
More informationExpressSAS Host Adapter 6Gb v2.10 Windows
Product Release Notes ExpressSAS Host Adapter 6Gb v2.10 Windows 1. General Release Information These product release notes define the new features, changes, known issues and release details that apply
More informationCore Switch PID Format Update Best Practices
Core Switch PID Format Update Best Practices For Immediate Release Updated 7/1/2002 Executive Summary There are certain parameters which must be set identically on all switches in a given fabric. In the
More informationFUJITSU Storage ETERNUS Multipath Driver (Oracle Solaris Version) Installation Information
FUJITSU Storage ETERNUS Multipath Driver (Oracle Solaris Version) Installation Information Jul 2015 Preface FUJITSU Storage ETERNUS Multipath Driver 3.1.0 is bundling two drivers. the driver for Solaris
More informationAusgewählte Betriebssysteme - Mark Russinovich & David Solomon (used with permission of authors)
Outline Windows 2000 - The I/O Structure Ausgewählte Betriebssysteme Institut Betriebssysteme Fakultät Informatik Components of I/O System Plug n Play Management Power Management I/O Data Structures File
More informationGuide to SiS RAID Utility for Windows XP / 2000
Guide to SiS RAID Utility for Windows XP / 2000 1. General 1. After installing the SiS RAID utility, go to Start menu and choose Programs. From the Programs menu, choose SiS RAID Utility and click on SiSRaid
More informationMASS-STORAGE STRUCTURE
UNIT IV MASS-STORAGE STRUCTURE Mass-Storage Systems ndescribe the physical structure of secondary and tertiary storage devices and the resulting effects on the uses of the devicesnexplain the performance
More informationChapter 13: I/O Systems
Chapter 13: I/O Systems I/O Hardware Application I/O Interface Kernel I/O Subsystem Transforming I/O Requests to Hardware Operations Streams Performance I/O Hardware Incredible variety of I/O devices Common
More informationComputer Architecture CS 355 Busses & I/O System
Computer Architecture CS 355 Busses & I/O System Text: Computer Organization & Design, Patterson & Hennessy Chapter 6.5-6.6 Objectives: During this class the student shall learn to: Describe the two basic
More informationETERNUS Disk storage systems Server Connection Guide (FCoE) for Linux
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More information