1 C122-E012-19EN PRIMEQUEST Fibre Channel card Users Guide 2G Fibre Channel PCI-X card (MC-08FC11/ MC-08FC71) 4G Fibre Channel PCI-X card (MC-08FC31/ MC-08FC41) 4G Fibre Channel PCI-express card (MC-08FC51/ MC-08FC61) 8G Fibre Channel PCI-express card (MC-08FC81/ MC-08FC91) MC IA Server Business Division Copyright FUJITSU LIMITED
2 Contents 1. Driver / TOOL / Firmware version The outline of this product Specification First setting by the EFI BIOS Setting Topology Setting Link Speed Changing the setting of opposed devices (Fibre Channel Switch / ETERNUS Disk Storage System) Installing Red Hat Linux / SUSE Linux driver Windows driver...11 Windows Server Confirming the version level of the driver that now in use Installing the driver and tool Confirming after Installing (Driver) Confirming after Installing (HBAnyware Utility, LightPulse Utility/NT) Windows Server Confirming the version level of the driver that now in use Installing the driver and tool Confirming after Installing (Driver) Confirming after Installing (HBAnyware Utility) Uninnstalling Red Hat Linux / SUSE Linux driver Windows driver Windows Server Uninstalling the driver Confirming after uninstalling Windows Server Uninstalling the driver Confirming after uninstalling Upgrade Red Hat Linux / SUSE Linux driver Windows driver Update of EFI / Firmware Instruction for proper use Mounting condition Limitations when Fibre Channel card is exchanged
3 9.3. Note EFI driver name Note when SAN configurations is changed (When EFI Driver before 3.11a4 is used.) Setting driver parameter Release Note for EFI Driver
4 1. Driver / TOOL / Firmware version Driver/TOOL/Firmware of following Version is in CD. [Driver / TOOL Version in Driver CD] OS Kernel version Version Linux Windows [Emulex LightPulse Fibre Channel Driver] About a number for kernel and a version of a driver, confirm README in directory: "kernel version" which this manual is arranged. Windows Server 2003 SP2 StorPort MiniPort Driver = HBAnyware =4.0a32 Windows Server Caution- With the installation of a driver for WS2003/WS2008, it is necessary to update Firmware/EFI Driver of FC card. Please inquire of Fujitsu service engineer about further information. [EFI Driver/Firmware Version in Driver CD] Firmware MC-08FC11/71 MC-08FC31 MC-08FC41 MC-08FC51 MC-08FC61 MC-08FC81 MC-08FC91 Shipment ver. 1.91a5 2.10a7 2.10a7 2.10a7 2.10a7 1.11a5 WS2003/2008 ver. 1.92a1 2.80a4 2.80a4 2.80a4 2.80a4 1.11a5 EFIDriver MC-08FC11/71 MC-08FC31 MC-08FC41 MC-08FC51 MC-08FC61 MC-08FC81 MC-08FC91 Shipment ver. 3.11x1 3.11x1 3.11x1 4.00a1 WS2003/2008 ver. 4.00a1 4.00a1 4.00a1 4.00a1 * As for Linux, use a shipment version. When MC08FC81/91 is used, the change of the following software/firmware is necessary. PAL/SAL Firmware : 3.10 or later. PSA(PRIMEQUEST Server Agent) : Linux is or later. Windows 2003 is or later. Windows2008 is or later. 4
5 2. The outline of this product 1) By mounting Fibre Channel card with PCI slot, you can add 1 or 2 port for Fibre Channel interface of 8 Gbps(800MB/s). 2) This card offers solutions for enterprise-class SAN(Storage Area Networks) 3. Specification (1) 2G Fibre Channel Card Item Specification Model Number MC-08FC11/ MC-08FC71 Host Bus Interface PCI-2.3, PCI-X 1.0a Standard/Transmission method/protocol FC-PI-2,FC-FS,FC-AL-2,FC-GS-4,FCP-2,RFC2625(IP over FC), FC-PH,FC-PH-2,FC-PH-3,FC-PI,FC-AL,FC-FLA,FC-PLDA,FC-TAPE,FCP Service class Class2, 3 Transmission media Multi-mode optical fibre cable (50/125μm MMF, Dual LC connector) Multi-mode optical fibre cable (62.5/125μm MMF, Dual LC connector) Data transfer rate MAX 200MB/s ( Synchronous transfer mode ) Connection distance MAX 300m (50/125μm) at 2Gbps MAX 150m (62.5/125μm) at 2Gbps Allotted number of ports The number of connecting 1 port MAX 126 devices / 1 Loop devices Form of connector Dual LC connector 5
6 (2) 4G Fibre Channel Card Item Specification Model Number MC-08FC31 MC-08FC41 MC-08FC51 MC-08FC61 Host Bus Interface PCI-2.3, PCI-X 1.0a PCI-Express 1.0a Standard/Transmission method/protocol FC-FS,FC-PH,FC-PI,FC-PI-2, FCP,FCP-2,FC-AL,FC-PLDA, FC-MI,FC-FLA, FC-FS,FC-PH-3,FC-PI-2,FC-TAPE, FCP-2,FC-AL-2,FC-PLDA,FC-GS-4, FC-FLA,RFC2625(IP over FC) RFC2625(IP over FC) Service class Class2, 3 Transmission media Multi-mode optical fibre cable (50/125μm MMF, Dual LC connector) Multi-mode optical fibre cable (62.5/125μm MMF, Dual LC connector) Data transfer rate MAX 400MB/s ( Synchronous transfer mode ) Connection distance MAX 150m(50/125μm) at 4Gbp MAX 70m(62.5/125μm) at 4Gbps Allotted number of ports 1 port 2 ports 1 port 2 ports The number of connecting MAX 126 devices / 1 Loop devices Form of connector Dual LC connector (3) 8G Fibre Channel Card Item Specification Model Number MC-08FC81 MC-08FC91 Host Bus Interface Fibre Channel PCI Express2.0 Standard/Transmission method/protocol FC-PI-4,FC-FS-2,FC-FS-2/AM1,FC-LS,AL-AL-2,FC-GS-6, FC-FLA,FC-PLDA,FC-TAPE,FC-DA,FCP through FCP-4, SBC-3,FC-SP,FC-HBA and SMI-S v1.1 Service class Class2, 3 Transmission media Multi-mode optical fibre cable (50/125μm MMF, Dual LC connector) Multi-mode optical fibre cable (62.5/125μm MMF, Dual LC connector) Data transfer rate MAX 800MB/s ( Synchronous transfer mode ) Connection distance MAX 50m(50/125μm) at 8Gbp MAX 21m(62.5/125μm) at 8Gbps Allotted number of ports 1 port 2 port The number of connecting devices MAX 126 devices / 1 Loop Form of connector SFP+short wave optical transce iver connector x1 SFP+short wave optical transce iver connector x2 6
7 4. First setting by the EFI BIOS <Start EFI BIOS setup screen> 1. Enter to EFI Shell by selecting "EFI Shell [Built-in]" in EFI Boot Manager first screen. 2. Confirm the driver number of the target card by performing confirm command in EFI Shell screen. Confirm command : Shell>drivers b 3. Confirm the numerical value NN (DRV / here, it is 22) at the beginning of the "Emulex SCSI Pass Thru Driver" from the displayed screen. T D D R Y C I P F A V VERSION E G G #D #C DRIVER NAME IMAGE NAME === ======== = = = ===== ============================== ============== B X X 6 1 Emulex SCSI Pass Thru Driver elxcli400a1 4. Start EFI BIOS screen with the numerical value that has been confirmed in section 3. Start command : Shell>drvcfg s Emulex FC EFI-Bios Utility is started Setting Topology Set as follows to connection form (Fablic / FCAL) in EFI-Bios. * It is equipped with two Single FC cards and two Dual FC card in the following EFI-Bios Utility screen. <Fablic > EFI-Bios Utility first screen 7
8 Select the target card that setting is changed 1) Select Setup Utility. 2) Select Configure HBA Parameters. 8
9 3) Select Topology Selection. 4) Select Point to Point. 9
10 <FCAL> The procedure that is selecting the target card that is changed setting is the same as <Fablic> 1) - 3). 4) Select FCAL Setting Link Speed Set as follows to connecting Link Speed (2/4/8Gbps) in EFI-Bios. Return to 4.1-3) screen by pushing Esc key in above screen and select "4. Force Link Speed". The initial setting is "Auto negotiate Default". Select Link speed to the using environment. 10
11 4.3. Changing the setting of opposed devices (Fibre Channel Switch / ETERNUS Disk Storage System) The setting opposed Fibre Channel Switch and ETERNUS Disk Storage System is needed to setting Fibr Channel Card. As for the detail, refer to ETERNUS Disk Storage System Settings / Setting the To-server Connection Type (Setting the CA Parameters) of ETERNUS disk storage system Server Connection GUIDE (Fibre Channel). 5. Installing 5.1. Red Hat Linux / SUSE Linux driver Confirm README in directory: "kernel version" which this manual is arranged Windows driver Please do not install, when current version is newer or same. Please install after ending all the applications. After installing, reboot the system so that the driver which is applied becomes effective. OS WS2003 SP2 WS2008 Windows Server 2003 InstallDriver Path DVD-ROM: Tools General Emulex APInstall.EXE DVD-ROM: Tools General Emulex APInstall.EXE Confirming the version level of the driver that now in use 1. Boot Windows Server 2003 and log on by the user with Administrator privileges. 2. Right-click the My Computer entry and click the Properties. 3. Click the Hardware tab of System properties and click the button, "Device Manager". "Device Manager" is displayed. 4. Click the "+" of the SCSI and RAID controllers and existing FC adapters are displayed. - It is displayed by either the following.( The display is different in each driver.) Emulex LightPulse LPxxxxx, PCI Slotxxx, Storport Miniport Driver Emulex LightPulse LPxxxxx, Storport Miniport Driver Emulex LightPulse HBA Storport Miniport Driver 11
12 Double-click the above icon. 5. Click the "Driver" tab and confirm the version level of the driver now in use Installing the driver and tool 1. Double-click the following files in the Driver CD: Tools\General\Emulex\APInstall.exe The Setup Wizard begins. 2. Click the "Next" button. 3. Start Driver Installation Issue screen. 4. Click the "Next" button. 5. Start install. 6. When "HBAnyware UtilityManagement Mode" screen is displayed, select the "Strictly Local Management" and click the "OK" button. 7. "Verify Installation" is finished in the Setup Wizard, click the "Next(N)" button. 8. The complete screen is displayed in the next screen, click the "Finish" button. * After rebooting the system, the driver which is applied becomes effective Confirming after Installing (Driver) Refer to Clause Confirming after Installing (HBAnyware Utility, LightPulse Utility/NT) 1. Click the Start button on the Taskbar. Confirm [Program](or [All programs]) [Emulex] [HBAnyware] is displayd. 2. Run HBAnyware. Click the Help and click the About HBAnyware. The window of HBAnyware About Box is displayed. Confirm the version level of HBAnyware. Windows Server Confirming the version level of the driver that now in use 1. Boot Windows Server 2008 and log on by the user with Administrator privileges. 2. Click the "+" of Diagnostics in Server Manager and display "Device Manager" by choosing it. 3. Click the "+" of Storage controllers, existing SCSI adapters are displayed. Double-click the Emulex LPX000 Fibre Channel Storport Driver icon. < Ex. > Emulex LPX000 Fibre Channel Storport Driver 12
13 4. Click the "Driver" tab and confirm the version level of the driver now in use. < Ex. > version / inbox driver) Installing the driver and tool 1. Double-click the following files in the Driver CD: Tools\General\Emulex\APInstall.exe The Setup Wizard begins. 2. Click the "Next" button. 3. Start Driver Installation Issue screen. 4. Click the "Next" button. 5. Start install 6. When "Autopilot Installer Warning" screen is displayed, click the "OK" button. 7. "Verify Installation" is finished in the Setup Wizard, click the "Next(N)" button. 8. The complete screen is displayed in the next screen, click the "Finish" button. * After rebooting the system, the driver which is applied becomes effective Confirming after Installing (Driver) Refer to Clause Confirming after Installing (HBAnyware Utility) 1. Click the Start button on the Taskbar. Confirm [Program](or [All programs]) [Emulex] [HBAnyware], [HBAnyware] is displayd. 2. Run HBAnyware. Click the Help and click the About HBAnyware. The window of HBAnyware About Box is displayed. Confirm the version level of HBAnyware. 6. Uninnstalling 6.1. Red Hat Linux / SUSE Linux driver Confirm README in directory: "kernel version" which this manual is arranged. 13
14 6.2. Windows driver Windows Server Uninstalling the driver 1. Click the "Start" button of the taskbar, and click the "Control panel" and "Addition and deletion of the program". The program being installed now is displayed. 2. Select the following programs and perform delete. Emulex Common SAN Management <Version> Emulex HBAnyware Utility <Version> Emulex Storport Miniport Driver Kit <Version> Click these. 3. Click the Change/Remove button. 4. The Uninstall Wizard begins. Click the Next button. 5. The Confirm Uninstall are displayd, Click the OK button, Uninstall starts. 6. The completion of Uninstall Wizard is displayed. Click the "Finish" button Confirming after uninstalling 1. Click the "Start" button of the taskbar, and click the "Control panel" and "Addition and deletion of the program". The program being installed now is displayed. 2. Confirm the following programs are deleted. Emulex Common SAN Management <Version> Emulex HBAnyware Utility <Version> Emulex Storport Miniport Driver Kit <Version> Windows Server Uninstalling the driver 1. Click the "Start" button of the taskbar and click the "Control panel" "Programs and Features".The program being installed now is displayed. 2. Select the following programs and perform delete. Emulex Common SAN Management <Version> Emulex HBAnyware Utility <Version> Emulex Storport Miniport Driver Kit <Version> Click these. 14
15 3. Right-click the target program and select "uninstallation and change (U)". 4. The Uninstall Wizard begins. Click the Next button. 5. The Confirm Uninstall are displayd, Click the OK button, Uninstall starts. 6. The completion of Uninstall Wizard is displayed. Click the "Finish" button Confirming after uninstalling 1. Click the "Start" button of the taskbar and click the "Control panel" "Programs and Features".The program being installed now is displayed. 2. Confirm the following programs are deleted. Emulex Common SAN Management <Version> Emulex HBAnyware Utility <Version> Emulex Storport Miniport Driver Kit <Version> 7. Upgrade 7.1. Red Hat Linux / SUSE Linux driver Confirm README in directory: "kernel version" which this manual is arranged Windows driver Follow the procedure "5.2.2 Installing the driver and tool(windows Server 2003)" or "5.2.6 Installing the driver and tool(windows Server 2008)" to upgrade the FC card driver. 15
16 8. Update of EFI / Firmware With the installation of Windows Server 2003 SP2 and Windows Server 2008, the firm up of the FC card will be necessary. For Firmup detail, ask a certified service engineer. 9. Instruction for proper use 9.1. Mounting condition The mounting slot of PCI Card is assigned. For further information, See the chapter Mounting conditions of PCI cards and usable built-in I/Os in PRIMEQUEST 580A/540A/580/540/480/440 SYSTEM DESIGN GUIDE (C122-B001-EN) See the chapter Mounting conditions of PCI cards and usable built-in I/Os in PRIMEQUEST 520A/520/420 SYSTEM DESIGN GUIDE (C122-B009-EN) 9.2. Limitations when Fibre Channel card is exchanged. <OS: Windows Server 2003 DTC, Windows Server 2003 EE, Windows Server 2008> -When you change Fibre Channel card used for boot path to other Fibre Channel card (other part# card), OS reinstall will be necessary. -No need to reinstall OS for the change between the same part# products. -No need to reinstall OS when Fibre Channel card is used for data path Note EFI driver name When it boots from SAN storage device and updates Firmware built-in PCI card, it should perform "drivers" command with EFI shell mode and confirm EFI Driver which displayed "Emulex SCSI Pass Thru Driver". When it uses EFI Driver version 3.11x1, it is displayed as follows by IMAGE NAME column, but there is no problem in movement. Also, when plural version coexists and they are displayed, please use the "VERSION" column that numerical value is big, so it is a new publication. 16
17 EFI Shell> drivers T D D Y C I R P F A V VERSION E G G #D#C DRIVER NAME IMAGE NAME === ======== = = = == === =================================== ================= ? X X - - Emulex SCSI Pass Thru Driver Elxcli310a B X X 2 1 Emulex SCSI Pass Thru Driver PciRom Seg= EFIDriver version 3.11x Note when SAN configurations is changed (When EFI Driver before 3.11a4 is used.) < Occurrence phenomenon > "EFI Internal Error2" is displayed in BOOT in SANBOOT environment by a screen, and there is the case that the phenomenon that a system is reset. < Occurrence condition > After it was done SANBOOT setting (WWPN of Boot Target setting), when FC switch and setting of the RAID side are changed, and it cannot be seen Boot Volume, it occurs. < Avoidance > (1) In the state that EFI system stands up (EFI prompt is displayed ( EFI Shell> )), change FC switch or setting of the RAID side, carry out Scan Target by all means, and set Boot Target again. (2) If FC switch or setting of the RAID side is changed in the state that EFI system does not stand up, in the state that the fiber cable which is connected to pertinent FC card is pulled, start EFI system (EFI prompt is displayed ( EFI Shell> )), connect fiber cable again, carry out Scan Target by all means, and set Boot Target again. 17
18 9.5. Setting driver parameter Driver palameter which is necessary when Fujitsu ETERNUS 3000/4000/8000 Disk Storage System and FC card be connected is described below. * As for the maximum speed of the using Fibre Channel card, confirm it in a product manual and Emulex corporation website. Emulex corporation website : < Linux OS > Confirm README in directory: "kernel version" which this manual is arranged. < Windows OS > Set the following driver parameters. 1 Start HBAnyware Utility. Click the [Start] button, [Program](or [All programs]) - [Emulex] - [HBAnyware], HBAnyware Utility is started. 2 Select the port every the pertience FC card and click the "Driver Parameters". When it is the same setting in all Fibre Channel cards, select locar server and select the "Driver Parameters". 18
19 3 Confirm the set point (Value) of each Adapter Parameter. Confirm and revise the set point that is mentioned in the following lists. Revise it (Value) in "Modify Adapter Parameters" by Adapter Parameter. - Windows Server 2003 SP1/SP2, 2008 Maximum data transfer Value rate Topology QueueDepth Queue LinkSpeed Target 8Gbps Fibre Channel card 4Gbps Fibre Channel card 2Gbps Fibre Channel card 0 (FCAL) 1(Fablic) ETERNUS8000,4000 is 254. ETERNUS2000 calculates (*2). 1 (*1) *1: Link Speed Fibre Channel card transfer rate Fablic (Fibre Channel Switch connection) FCAL 8Gbps 4Gbps 2Gbps 1Gbps ET8000/ET4000 ET2000 FC-CA (4G) FC-CA (8G) 8Gbps Gbps Gbps *2: In ETERNUS2000, set the value that is calculated in the following expression. The value = 40 / the number of Fibre Channel port that is connected a CA port (The decimal point cuts it off). When the value is smaller than 8, set it in 8. Caution : Change only the parameters that is explained here. 19
20 < Explanation of parameter > - Topology It sets a connection form PRIMEQUEST and ETERNUS Disk Storage System. - QueueDepth It sets the number of the command cues. - QueueTarget It sets the number of the command cues for LUN or a target. - LinkSpeed It sets Link Speed. 4 Click the "Apply" button after revising the value. As for the parameter displayed with red in Adapter Parameter, the value is not changed. Click the "Aplly" button. 5 When the every several cards are changed the value, repeat the above perform 1 ~ 4. < Notes when LinkSpeed is set > When LinkSpeed parameter setting of a PCI card is made a mistake in, it may result in OSBoot is impossible in SANBoot environment. < Ex. > The case of LinkSpeed parameter of 4G Fibre Channel Card (MC-08FC31/41/51/61) is set "LinkSpeed=4" and FC-AL connection/ fabric connection is connected to other party of CA corresponding to 2Gbps. 20
21 6 Finish HBAnyware Utility by selecting Exit in File after completing the all setting. The values that are changed become effective after rebooting the server. 7 Reboot the server after revising the values. The setting that is changed become effective after rebooting the server Release Note for EFI Driver It may result in there is no Dual Channel card notation for pertinence EFIDriver Release Note in "PRIMEQUEST Firmware CD(C122-E018)", but when there is the description of the same kind of Single Channel card, it may have applicability to it. < Ex.> When there is the description of following Single Channel(Lp11000) in Release Note, the application of Dual Channel(Lp11002) is possible. BE311X1.PRG Lp11000 EFIBoot version 3.11X1 21
The Contents and Structure of this Manual. This document is composed of the following three chapters and an appendix.
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationHP StorageWorks Emulex host bus adapters for x86 and x64 Linux and Windows systems release notes
HP StorageWorks Emulex host bus adapters for x86 and x64 Linux and Windows systems release notes Part number: AV-RUPXS-TE Eighteenth edition: September 2006 Description These release notes contain information
More informationC122-E159-02EN PRIMEQUEST 1000 Series Notices for ServerView Suite
PRIMEQUEST 1000 Series Notices for ServerView Suite 2012 January FUJITSU LIMITED Contents I. Preface... 3 II. Notices for ServerView Suite V10.11.07... 4 1. Notices for ServerView Operations Manager (SVOM)...
More informationFUJITSU Server PRIMEQUEST 1000 Series How to Confirm the IO Product Version
C122-E162-02EN FUJITSU Server PRIMEQUEST 1000 Series How to Confirm the IO Product Version This document describes how to confirm the firmware versions of IO products. CHAPTER 1 Firmware Version of the
More informationServer Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationDell PowerEdge 6 Gbps SAS HBA and Internal Tape Adapter. User s Guide
Dell PowerEdge 6 Gbps SAS HBA and Internal Tape Adapter User s Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:
More informationHP StorageWorks Booting Windows Server 2003 for Itanium-based systems from a storage area network application notes
HP StorageWorks Booting Windows Server 2003 for Itanium-based systems from a storage area network application notes Part number: AA RV22F TE Sixth edition: August 2006 Legal and notice information Copyright
More informationSCSIport Miniport Driver
SCSIport Miniport Driver Version 5.20a9 for Windows Server 2003 and Windows 2000 Server User Manual Copyright 2005 Emulex Corporation. All rights reserved worldwide. No part of this document may be reproduced
More informationThe Contents and Structure of this Manual. This document is composed of the following six chapters and an appendix.
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationHS22, HS22v, HX5 Boot from SAN with QLogic on IBM UEFI system.
HS22, HS22v, HX5 Boot from SAN with QLogic on IBM UEFI system. Martin Gingras Product Field Engineer, Canada mgingras@ca.ibm.com Acknowledgements Thank you to the many people who have contributed and reviewed
More informationETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationHP StorageWorks QLogic host bus adapters for x86 and x64 Linux and Windows and x86 NetWare release notes
HP StorageWorks QLogic host bus adapters for x86 and x64 Linux and Windows and x86 NetWare release notes Part number: AV-RSBNV-TE Twentieth edition: January 2007 Description These release notes contain
More informationMSA1500csReleaseNotes8_ txt MSA1500cs ReleaseNotes. hp StorageWorks Modular Smart Array 1500 cs Release Notes. Third Edition (February 2005)
MSA1500cs ReleaseNotes hp StorageWorks Modular Smart Array 1500 cs Release Notes Third Edition (February 2005) Publication of the third edition of this document coincides with the release of MSA1500 cs
More informationFirmware. Update Manual for Sun-Branded Fibre Channel Adapters by Emulex
Firmware Update Manual for Sun-Branded Fibre Channel Adapters by Emulex Copyright 2007 Emulex Corporation. All rights reserved worldwide. No part of this document may be reproduced by any means nor translated
More informationServer Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationEmulex Drivers Version 10.6 for Windows. Quick Installation Manual
Emulex Drivers Version 10.6 for Windows Quick Installation Manual Connect Monitor Manage 2 Copyright 2003-2015 Emulex. All rights reserved worldwide. No part of this document may be reproduced by any means
More informationETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Linux
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationEmulex Drivers Version 10.2 for Windows
Emulex Drivers Version 10.2 for Windows Quick Installation Manual Emulex Connects Servers, Storage and People 2 Copyright 2003-2014 Emulex. All rights reserved worldwide. No part of this document may be
More informationFC HBA STOR Miniport Driver for Windows. Table of Contents
FC HBA STOR Miniport Driver for Windows This software license applies only to QLogic customers. QLogic Corporation. All rights reserved. 1. Package Contents 2. OS Support 3. Supported Features 4. Using
More information[ User s Guide] QLA 200 Family. User s Guide FIBRE CHANNEL HBA INSTALLATION
[ User s Guide] User s Guide FIBRE CHANNEL HBA INSTALLATION P QLA 200 Family Covers the following operating systems: Windows 2000 Windows Server 2003 Red Hat Linux SuSE Linux NetWare Technical Support
More informationDell Host Bus Adaptor User s Guide
Dell Host Bus Adaptor User s Guide Regulatory Model: UCSE 900 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION
More informationPRIMERGY BX900/BX400 Blade Server Systems
Installation Guide PRIMERGY BX900/BX400 Blade Server Systems Fujitsu Converged Network Adapter (CNA) for Blade Systems 1.0 PRIMERGY CNA Mezzanine Card 10Gbit/s 2-port (MC-CNA102E) for BX9xx Server Blades
More informationSANsurfer iscsi HBA Application User s Guide
Q Simplify SANsurfer iscsi HBA Application User s Guide Management Application for SANsurfer iscsi Host Bus Adapters IS0054602-00 A Page i SANsurfer iscsi HBA Application User s Guide Management Application
More informationStorageWorks Dual Channel 4Gb, PCI-X-to-Fibre Channel Host Bus Adapter for Windows and Linux (Emulex LP11002)
Models FC2143 4Gb PCI-X 2.0 HBA FC2243 Dual 4Gb PCI-X 2.0 HBA FC1143 4Gb PCI-X 2.0 HBA FC1243 Dual 4Gb PCI-X 2.0 HBA StorageWorks 4Gb, PCI-X-to-Fibre Host Bus Adapter for Windows and Linux. (Emulex LP1150)
More informationFibre Channel Adapter STOR Miniport Driver for Windows. Table of Contents
Fibre Channel Adapter STOR Miniport Driver for Windows QLogic Corporation All rights reserved Table of Contents 1. Package Contents 2. OS Support 3. Supported Features 4. Using the Driver 4.1 Creating
More informationETERNUS Multipath Driver (Windows Version) Installation Information
(Windows Version) Installation Information September 2011 Contents About for Windows...4 Supported Operation System (OS) Versions...5 Supported Disk Storage Systems...6 ETERNUS DX60, ETERNUS DX80, ETERNUS
More informationHP StorageWorks Emulex Adapters Release Notes
HP StorageWorks Emulex Adapters Release Notes Part number: AA-RWQ7A-TE First edition: February 2010 Legal and notice information Copyright 2010 Hewlett-Packard Development Company, L.P. Description These
More informationPRIMEQUEST 500A/500 SERIES
U41805-J-Z816-2-76/C122-E087-03EN PRIMEQUEST 500A/500 SERIES Microsoft Windows Server 2008 USER'S GUIDE Preface Purpose This manual explains the preparations and procedures for installing Windows Server
More informationEmulex Drivers for Windows for LightPulse Adapters. User Guide Release 12.0
Emulex Drivers for Windows for LightPulse Adapters User Guide Release 12.0 July 5. 2018 , the pulse logo, Connecting everything, Avago Technologies, Avago, and the A logo are among the trademarks of and/or
More informationHP StorageWorks QLogic Fibre Channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes
HP StorageWorks QLogic Fibre Channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes Part number: AA-RWFNF-TE Fourteenth edition: April 2009
More informationEmulex 16Gb Gen 5 Fibre Channel Adapters for IBM System x IBM Redbooks Product Guide
Emulex 16Gb Gen 5 Fibre Channel Adapters for IBM System x IBM Redbooks Product Guide The Emulex 16Gb Fibre Channel (FC) host bus adapters (HBAs) for IBM System x are part of a family of high-performance
More informationIBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix
IBM System Storage DS3000 series Interoperability Matrix - 1 - IBM System Storage DS3000 series Interoperability Matrix Last Revised: 8/28/2007 IBM System Storage DS3000 series Interoperability Matrix
More informationx10sure 3.2 One to one recover after repair
x10sure 3.2 One to one recover after repair 1 1:1 WITH EXTERNAL STORAGE 2 1.1 After power failure etc. 2 1.2 After repair 2 1.3 After replacement of the failed node 3 1.3.1 Boot device via FC 3 1.3.2 Boot
More informationETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationTerminology. This document uses the following terms:
CX4 Architecture for NS Series Connecting a CX4-48 Storage System in a Fibre Channel Direct or Switch Configuration with a Microsoft Windows Server with Native Multipath Failover December 6, 28 If you
More informationIBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix
IBM System Storage DS3000 series Interoperability Matrix - 1 - IBM System Storage DS3000 series Interoperability Matrix Last Revised: 9/19/2007 IBM System Storage DS3000 series Interoperability Matrix
More informationEmulex Drivers for Windows for LightPulse Adapters
Emulex Drivers for Windows for LightPulse Adapters Quick Installation Guide Version 11.4 DRVWin-LPE-IG114-100 Corporate Headquarters San Jose, CA Website www.broadcom.com, the pulse logo, Connecting everything,
More informationATTO Celerity Fibre Channel Host Adapters Installation and Operation Manual
ATTO Celerity Fibre Channel Host Adapters Installation and Operation Manual Celerity FC-164E 16Gb FC quad channel PCIe 3.0 host adapter Celerity FC-162E 16Gb FC dual channel PCIe 3.0 host adapter Celerity
More informationEmulex Drivers for Linux for LightPulse Adapters Release Notes
Emulex Drivers for Linux for LightPulse Adapters Release Notes Versions: FC Version 11.4.142.21 Date: September 6, 2017 Purpose and Contact Information These release notes describe the new features, current
More informationServer Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationEmulex Drivers for Windows for OneConnect Adapters
Emulex Drivers for Windows for OneConnect Adapters Quick Installation Guide Version 11.2 DRVWINOCA-IG112 Corporate Headquarters San Jose, CA Website www.broadcom.com, the pulse logo, Connecting everything,
More informationA9890A RAID Smart Array 6402 Controller Quick Installation Guide
A9890A RAID Smart Array 6402 Controller Quick Installation Guide Quick Installation of the Smart Array 6402 Controller Edition 1 Manufacturing Part Number: A9890-90005 March 2004 United States Copyright
More informationThe HBAs tested in this report are the Brocade 825 and the Emulex LightPulse LPe12002 and LPe12000.
HBA Product Evaluation Evaluation report prepared under contract with Corporation Introduction Due to increased interest in 8 Gb/s Fibre Channel host bus adapters, Corporation commissioned Demartek to
More informationDell Storage Center OS Version 7 Software Update Guide
Dell Storage Center OS Version 7 Software Update Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates
More informationQLogic Fibre Channel Adapter Stor Miniport Driver for Windows Server 2003/Windows XP Professional. Table of Contents
QLogic Fibre Channel Adapter Stor Miniport Driver for Windows Server 2003/Windows XP Professional This software license applies only to QLogic customers. QLogic Corporation. All rights reserved. Table
More informationConfiguring Server Boot
This chapter includes the following sections: Boot Policy, page 1 UEFI Boot Mode, page 2 UEFI Secure Boot, page 3 CIMC Secure Boot, page 3 Creating a Boot Policy, page 5 SAN Boot, page 6 iscsi Boot, page
More informationreadme.txt README.TXT
README.TXT Adaptec ASR-5085/ASR-5405/ASR-5445/ASR-5805/ASR-51245/ASR-51645/ASR-52445 Unified Serial Controllers Adaptec ASR-2045/ASR-2405 Unified Serial Controllers Adaptec ASR-5405Z/ASR-5445Z/ASR-5805Z
More informationLenovo ThinkServer Advanced 8 Gb and 16 Gb (Gen 5) Fibre Channel HBAs by Emulex Product Guide
Lenovo ThinkServer Advanced 8 Gb and 16 Gb (Gen 5) Fibre Channel HBAs by Emulex Product Guide The Lenovo ThinkServer Advanced 8 Gb and 16 Gb (Generation 5) Fibre Channel (FC) host bus adapters (HBAs) by
More informationThe Contents and Structure of this Manual. This document is composed of the following three chapters.
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationREADME.TXT
README.TXT Adaptec ASR-4800SAS/ASR-4805SAS RAID Controller Adaptec AAR-2420SA/AAR-2820SA SATA RAID Controller Adaptec ASR-2130SLP/ASR-2230SLP SCSI RAID Controller Adaptec ASR-3085/ASR-3405/ASR-3805/ASR-31205/ASR-31605
More informationFUJITSU Storage ETERNUS Multipath Driver (Windows Version) Installation Information
FUJITSU Storage ETERNUS Multipath Driver (Windows Version) Installation Information Jul 2015 Contents About ETERNUS Multipath Driver for Windows... 4 Supported Operation System (OS) Versions... 5 Supported
More informationHP StorageWorks SmartStart EVA Storage 3.2 Release Notes
HP StorageWorks SmartStart EVA Storage 3.2 Release Notes Part Number: T5505-96034 Second edition: June 2010 Legal and notice information Copyright 2010 Hewlett-Packard Development Company, L.P. Microsoft
More informationQuick Setup Guide RAID Array 8000/ESA12000 Fibre Channel Storage Subsystem for SGI IRIX
Quick Setup Guide RAID Array 8000/ESA12000 Fibre Channel Storage Subsystem for SGI IRIX AA RFBHA TE 387398-001 Before You Begin In this Quick Setup Guide we tell you how to create an initial hardware configuration
More informationRAID SATA II 3Gbps 4 Ports PCI-X Host
RAID SATA II 3Gbps 4 Ports PCI-X Host User Manual English LINDY No. 70548 (External) LINDY No. 70549 (Internal) www.lindy.com LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - FIRST EDITION (November
More informationEmulex -branded Fibre Channel HBA Product Line
Emulex -branded Fibre Channel HBA Product Line Emulex-branded Fibre Channel (FC) Host Bus Adapters (HBAs) by Broadcom are designed to address the demanding performance, reliability and management requirements
More informationIBM Flex System FC port 16Gb FC Adapter Lenovo Product Guide
IBM Flex System FC5172 2-port 16Gb FC Adapter Lenovo Product Guide The IBM Flex System FC5172 2-port 16Gb FC Adapter enables high-speed access for IBM Flex System compute nodes to connect to a Fibre Channel
More informationWARNING USING THIS SOFTWARE IS NOT A TRIVIAL UPGRADE TO EXISTING RAID INSTALLATIONS!
Precautions and Alerts - SRCU31, SRCU31A, SRCU31L and SRCU31L-A WARNING USING THIS SOFTWARE IS NOT A TRIVIAL UPGRADE TO EXISTING RAID INSTALLATIONS! 1. For any NEW installations with only one Intel RAID
More informationFUJITSU Storage ETERNUS Multipath Driver (Windows Version) Installation Information
FUJITSU Storage ETERNUS Multipath Driver (Windows Version) Installation Information Nov 2017 Contents About ETERNUS Multipath Driver for Windows... 4 Supported Operation System (OS) Versions... 5 Supported
More informationDell EMC Host Bus Adapter User's Guide
Dell EMC Host Bus Adapter User's Guide HBA330 and External 12 Gbps SAS HBA Regulatory Model: UCSE 900, UCSF-1000, UCSN-1000 Notes, cautions, and warnings NOTE: A NOTE indicates important information that
More informationIBM System Storage DS3000 Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix
IBM System Storage DS3000 Interoperability Matrix - 1 - IBM System Storage DS3000 series Interoperability Matrix Last Revised: July 29, 2008 IBM System Storage DS3000 Interoperability Matrix - 2 - Table
More informationHP StorageWorks Emulex fibre channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes
HP StorageWorks Emulex fibre channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes Part number: AA-RWF7L-TE Eleventh edition: March 2009 Description
More informationBefore Reading This Manual This section explains the notes for your safety and conventions used in this manual.
Integrated Mirroring SAS User s Guide Areas Covered Before Reading This Manual Chapter 1 Chapter 2 Chapter 3 This section explains the notes for your safety and conventions used in this manual. Overview
More informationDell EMC OpenManage Deployment Toolkit for
2017-09 Dell EMC OpenManage Deployment Toolkit 6.0.2 for This document describes the new features, enhancements, and fixed issues in Dell Openmanage Deployment Toolkit 6.0.2 for Embedded Linux Topics:
More informationConfiguring the MSA1000 for Linux or NetWare Environments
White Paper September 2002 Prepared by: Network Storage Solutions Hewlett Packard Company Contents Benefits of the new firmware for the MSA1000...1 Prerequisites...3 Firmware Upgrades:...3 Environmental
More informationOverview. Implementing Fibre Channel SAN Boot with Oracle's Sun ZFS Storage Appliance. August By Tom Hanvey; update by Peter Brouwer
Implementing Fibre Channel SAN Boot with Oracle's Sun ZFS Storage Appliance August 2012 By Tom Hanvey; update by Peter Brouwer This paper describes how to implement a Fibre Channel (FC) SAN boot solution
More informationBoot Manual. For Emulex OneConnect Adapters. Emulex Connects
Boot Manual For Emulex OneConnect Adapters P007007-01A Rev. A Emulex Connects Servers, Storage and People Copyright 2003 2011 Emulex. All rights reserved worldwide. No part of this document may be reproduced
More informationInstallation and Operation Manual Celerity FC host adapters
Installation and Operation Manual Celerity FC host adapters Celerity FC-41EN 4-Gb FC single channel host adapter Celerity FC-42EN 4-Gb FC dual channel host adapter Celerity FC-44ES 4-Gb FC quad channel
More informationQuickSpecs. Useful Web Sites For additional information, see the following web sites: Linux Operating System. Overview. Retired
Overview NOTE: HP no longer sells RHEL and SLES on Integrity servers. HP will continue to support RHEL 5 on Integrity servers until Red Hat's end of support life date for RHEL 5 (March 31st, 2017). HP
More informationS SNIA Storage Networking Management & Administration
S10 201 SNIA Storage Networking Management & Administration Version 23.3 Topic 1, Volume A QUESTION NO: 1 Which two (2) are advantages of ISL over subscription? (Choose two.) A. efficient ISL bandwidth
More informationIntellex Digital Video Management System. Installing a CD-RW in Intellex
Intellex Digital Video Management System Installing a CD-RW in Intellex 2 Intellex Digital Video Management System Notice Copyright The information in this manual was current when published. The manufacturer
More informationETERNUS Disk storage systems Server Connection Guide (FCoE) for Linux
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationHP Supporting the HP ProLiant Storage Server Product Family.
HP HP0-698 Supporting the HP ProLiant Storage Server Product Family https://killexams.com/pass4sure/exam-detail/hp0-698 QUESTION: 1 What does Volume Shadow Copy provide?. A. backup to disks B. LUN duplication
More informationRAID Native SATA Ports PCI Host
RAID Native SATA 150 4 Ports PCI Host User Manual English LINDY No. 70541 (Internal 4 Port) LINDY No. 70542 (External 2 Port + Internal 2 Port) www.lindy.com LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK
More informationATTO Celerity Fibre Channel Host Adapters Installation and Operation Manual
ATTO Celerity Fibre Channel Host Adapters Installation and Operation Manual Celerity FC-164E 16Gb FC quad channel PCIe 3.0 host adapter Celerity FC-162E 16Gb FC dual channel PCIe 3.0 host adapter Celerity
More informationFUJITSU Server PRIMEQUEST 1000 Series
FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration Manual C122-E155-04EN Preface This manual is a revised version of APPENDIX D Configuring the SAN Boot Environment from the PRIMEQUEST
More informationAppendix A Fast!UTIL
Appendix A Fast!UTIL This appendix is part of the QLogic Corporation manual Hardware Installation Guide for the QLA1xxx Boards (PC0056105-00 E). The QLogic disclaimer and copyright notices for this document
More informationDell EMC PowerEdge Systems SUSE Linux Enterprise Server 15. Installation Instructions and Important Information
Dell EMC PowerEdge Systems SUSE Linux Enterprise Server 15 Installation Instructions and Important Information Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you
More informationReinstalling the Operating System on the Dell PowerVault 745N
Reinstalling the Operating System on the Dell PowerVault 745N This document details the following steps to reinstall the operating system on a PowerVault 745N system: 1. Install the Reinstallation Console
More informationSUN STORAGETEK DUAL 8 Gb FIBRE CHANNEL DUAL GbE EXPRESSMODULE HOST BUS ADAPTER
SUN STORAGETEK DUAL 8 Gb FIBRE CHANNEL DUAL GbE EXPRESSMODULE HOST BUS ADAPTER KEY FEATURES MULTIPROTOCOL NETWORK HOST BUS ADAPTER FOR SUN BLADE SERVERS Comprehensive virtualization capabilities with support
More informationFUJITSU Server PRIMEQUEST 1000 Series
FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration Manual C122-E155-05EN Preface This manual is a revised version of APPENDIX D Configuring the SAN Boot Environment from the PRIMEQUEST
More informationDtS Data Migration to the MSA1000
White Paper September 2002 Document Number Prepared by: Network Storage Solutions Hewlett Packard Company Contents Migrating Data from Smart Array controllers and RA4100 controllers...3 Installation Notes
More informationreadme.txt README.TXT
README.TXT Adaptec ASR-5085/ASR-5405/ASR-5445/ASR-5805/ASR-51245/ASR-51645/ASR-52445 Unified Serial Controllers Adaptec ASR-2045/ASR-2405 Unified Serial Controllers as of December 5, 2008 Please review
More informationEMC Fibre Channel with QLogic Host Bus Adapters in the Windows Environment
EMC Fibre Channel with QLogic Host Bus Adapters in the Windows Environment P/N 300-001-164 REV A07 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508 -435-1000 www.emc.com Copyright
More informationConfiguring the HP StorageWorks Modular Smart Array 1000 and 1500cs for external boot with Novell NetWare New Installations
Technical Note Revised October 2006 Prepared by: Network Storage Solutions Hewlett Packard Company Contents Configuring the StorageWorks MSA1000 and MSA1500cs for External Boot with NetWare Considerations...3
More informationSystem Storage DS3950 Quick Start Guide
System Storage DS3950 Quick Start Guide This Quick Start Guide describes the basic procedure for installing, cabling, and configuring the IBM System Storage DS3950 storage subsystem (Machine Types 1814-94H
More informationCisco UCS Virtual Interface Card Drivers for Windows Installation Guide
Cisco UCS Virtual Interface Card Drivers for Windows Installation Guide First Published: 2011-09-06 Last Modified: 2015-09-01 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA
More informationSeries Controller_Readme_8_2010.txt README.TXT
README.TXT Adaptec ASR-5085/ASR-5405/ASR-5445/ASR-5805/ASR-51245/ASR-51645/ASR-52445 Unified Serial Controllers Adaptec ASR-5405Z/ASR-5445Z/ASR-5805Z Unified Serial Controllers Adaptec ASR-5805Q/ASR-5805ZQ
More informationHP StorageWorks Emulex fibre channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes
HP StorageWorks Emulex fibre channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes Part number: AA-RWF7J-TE Ninth edition: January 2009 Description
More informationHP StorageWorks Emulex fibre channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes
HP StorageWorks Emulex fibre channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes Part number: AA-RWF7N-TE Thirteenth edition: April 2009
More informationUpgrading the MSA1000 for Enhanced Features
White Paper December 2002 Prepared by: Network Storage Solutions Hewlett Packard Company Contents Benefits of the MSA1000 Enhancements...1 Prerequisites...3 Environmental Monitoring Unit (EMU) issue:...3
More informationHP StorageWorks Emulex Fibre Channel host bus adapters for ProLiant and Integrity servers using Linux, VMware and Citrix operating systems release
HP StorageWorks Emulex Fibre Channel host bus adapters for ProLiant and Integrity servers using Linux, VMware and Citrix operating systems release notes Part number: AA-RWF7R-TE Fifteen edition: November
More informationConfiguration Guide -Server Connection-
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Citrix XenServer This page is intentionally left blank. Preface This manual briefly explains the operations
More informationHP StorageWorks QLogic fibre channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes
HP StorageWorks QLogic fibre channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes Part number: AA-RW7JW-TE Sixth edition: November 2007 Description
More informationFlex System FC port 8Gb FC Adapter Lenovo Press Product Guide
Flex System FC3172 2-port 8Gb FC Adapter Lenovo Press Product Guide The Flex System FC3172 2-port 8Gb FC Adapter enables high-speed access for Flex System compute nodes to connect to a Fibre Channel storage
More informationEMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N REV A05
EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N 300-002-038 REV A05 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2004-2006
More informationInstallation of fi-4110cu Scanner under Windows 2000
Installation of fi-4110cu Scanner under Windows 2000 Connect the scanner to the PC. Turn on the scanner and then the PC Log into Windows Note: The user must log in with administrator authority. For information
More informationDeployment Guide: Network Convergence with Emulex OneConnect FCoE CNA and Windows Server Platform
W h i t e p a p e r Deployment Guide: Network Convergence with Emulex OneConnect FCoE CNA and Windows Server Platform How to Deploy Converged Networking with a Windows Server Platform Using Emulex OneConnect
More informationEmulex Drivers for Windows. Quick Installation Guide Release 12.2
Emulex Drivers for Windows Quick Installation Guide Release 12.2 January 28. 2019 , the pulse logo, Connecting everything, Avago Technologies, Avago, the A logo, Emulex, LightPulse, OneCommand, and OneConnect
More informationQuickSpecs. Models. HP StorageWorks 8Gb PCIe FC HBAs Overview
Overview Models HP StorageWorks 81Q PCIe FC HBA Single Port HP StorageWorks 82Q PCIe FC HBA Dual Port HP StorageWorks 81E PCIe FC HBA Single Port HP StorageWorks 82E PCIe FC HBA Dual Port Description StorageWorks
More informationreadme.txt README.TXT
README.TXT Adaptec ASR-5085/ASR-5405/ASR-5445/ASR-5805/ASR-51245/ASR-51645/ASR-52445 Unified Serial Controllers Adaptec ASR-5405Z/ASR-5445Z/ASR-5805Z Unified Serial Controllers Adaptec ASR-5805Q/ASR-5805ZQ
More information