1 GECMA Components GmbH Operating Manual ExMod Ex-Module Base station e.g. for BCSi / Data transmission module Doc.Nr.: MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B -1-

2 List of Contents List of Contents...2 Introduction...2 ExMod models available...3 Technical Data...5 Certificates...6 Programming of ExMod-RF10/RF Assembly...10 Connections details...11 Terminal Connections...20 Safety Instructions...22 General Instructions...23 Drawings and certifications...23 Introduction The ExMod are designed as base station for cable and RF barcode scanner. Depending on the variant it contains intrinsically safe power supplies, barriers, a charging circuit, a Bluetooth interface and various data transmission interfaces. Furthermore the ExMod designed as data transmission module to transmit data from a device (e.g. Cardreader) located in hazardous area to the safe area. Depending on the variant it contains intrinsically safe power supplies, barriers and various data transmission interfaces. The data of devices can be transmitted via serial interfaces (Ex-i and/or Ex-e): (RS232i / RS232e) or (RS422i / RS422e). Depending on the interface type selected (e.g. RS422e) distances up to 1000m (3300ft) are possible between the ExMod and appropriated devices in safe area. If necessary the signals can be converted via appropriated devices (not included) in safe area. For RS422e signals we recommend as appropriate devices e.g. the RS422/USB converter type Expert EX9531. The connections are realized via Ex e connection box and via Ex i interfaces. All versions of the ExMod are for use in hazardous areas Zone 1[0], Zone 21[20], EPL Gb[Ga], EPL Db[Da] MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B - 2 -

3 ExMod models available Various models of ExMod can be supplied: The first parameter -1- will define the form of the input data of Ex-Module. It will contain the radio frequency Bluetooth module or will contain an intrinsically safe serial input interface with a power of 5V or 12V. The second parameter -2- will define the form of the outputs signals of ExMod: RS232i-RS232e or RS422i/RS422e. The third parameter -3- will define the supply input power of ExMod: AC/DC or DC/DC. -1 = RF10: Base station with Bluetooth radio frequency module (10mW). In this variant we receive datas transmitted by any Bluetooth module. The integrated Bluetooth module in ExMod send these data via a serial interface, RS232 or RS422. This variant also contains: - Intrinsically safe charging interface for a battery. - Intrinsically safe interface for external antenna. - Intrinsically safe RESET button/interface for Bluetooth module. RF100: Base station with Bluetooth radio frequency module (100mW). In this variant we receive datas transmitted by any Bluetooth module. The integrated Bluetooth module in ExMod send these data via a serial interface, RS232 or RS422. This variant also contains: - Intrinsically safe charging interface for a battery. - Intrinsically safe interface for external antenna. - Intrinsically safe RESET button/interface for Bluetooth module. 5V HP: Data transmission module contains an interface which provide an intrinsically safe RS232 interface with 5V Ex ia high power interface. 5V LP: Data transmission module contains an interface which provide an intrinsically safe RS232 interface with 5V Ex ia low power interface. 12V HP: Data transmission module contains an interface which provide an intrinsically safe RS232 interface with 12V Ex ia high power interface. - 2 = RS232: The output signals of ExMod are realized via a serial RS232 interface. In this case the ExMod contains two outputs: an intrinsically safe (Ex i) serial interface RS232i and an increased safety (Ex-e) serial interface RS232e (use one interface only!). RS422i: The output signals of ExMod are realized via serial intrinsically safe signals (EX i) RS422i. RS422e: The output signals of ExMod are realized via serial increased safe signals (EX e) RS422e. - 3 = AC: Supplied with 100VAC 230VAC (±10%), Hz DC24: Supplied with VDC MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B - 3 -

4 Example: ExMod RF RF RS485 RS485i-AC = ExModule (base station) with integrated 100mW Bluetooth module, output data as RS485i (intrinsically safe serial interface), supplied with 100VAC 230VAC Model name Description 1 ExMod-RF 10-RS422i-3 2 ExMod-RF 10-RS422e-3 3 ExMod-RF 10-RS ExMod-RF 100-RS422i-3 5 ExMod-RF 100-RS422e-3 6 ExMod-RF 100-RS ExMod-5V LP-RS422i-3 8 ExMod-5V HP-RS422i-3 9 ExMod-12V HP-RS422i-3 10 ExMod-5V LP-RS422e-3 11 ExMod-5V HP-RS422e-3 12 ExMod-12V HP-RS422e-3 13 ExMod-5V LP-RS ExMod-5V HP-RS ExMod-12V HP-RS232-3 Base station with integrated 10mW Bluetooth module and RS422 Ex ia output interface Base station with integrated 10mW Bluetooth module and RS422 Ex e output interface Base station with integrated 10mW Bluetooth module and RS232 Ex ia output interface and RS232 Ex e output interface Base station with integrated 100mW Bluetooth module and RS422 Ex ia output interface Base station with integrated 100mW Bluetooth module and RS422 Ex e output interface Base station with integrated 100mW Bluetooth module and RS232 Ex ia output interface and RS232 Ex e output interface Data transmission module with RS232 Ex ia input interface with 5V Ex ia low power interface and RS422 Ex ia output interface Data transmission module with RS232 Ex ia input interface with 5V Ex ia high power interface and RS422 Ex ia output interface Data transmission module with RS232 Ex ia input interface with 12V Ex ia high power interface and RS422 Ex ia output interface Data transmission module with RS232 Ex ia input interface with 5V Ex ia low power interface and RS422 Ex e output interface Data transmission module with RS232 Ex ia input interface with 5V Ex ia high power interface and RS422 Ex e output interface Data transmission module with RS232 Ex ia input interface with 12V Ex ia high power interface and RS422 Ex e output interface Data transmission module with RS232 Ex ia input interface with 5V Ex ia low power interface and RS232 Ex ia output interface and RS232 Ex e output interface Data transmission module with RS232 Ex ia input interface with 5V Ex ia high power interface and RS232 Ex ia output interface and RS232 Ex e output interface Data transmission module with RS232 Ex ia input interface with 12V Ex ia high power interface and RS232 Ex ia output interface and RS232 Ex e output interface MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B - 4 -

5 Technical Data For all ExMod versions: Housing type: Ingress protection: Operating temperature range: Storage temperature: Hazardous areas: Dimensions: Weight: Power consumption: Classification of install. and use: Interfaces: Data Interfaces: Stainless steel / AISI 304 (or on request) IP64-20 C to +60 C (-4 F to 140 F), 15 to 95% rel. humidity, n. cond. -20 C C (-4 F to 158 F), 15 to 85% rel. humidity, n. cond. Zone 1[0], Zone 21[20], EPL Gb[Ga], EPL Db[Da] (refer certificates) 321 mm x 125 mm x 47 mm (12,65 x 4,92 x 1,85 ), refer to attached drawings typ. 4.7kg (10,4 lb), depending on variant typ. 10W / max. 15W (typ. 34BTU / max. 51BTU) stationary refer chapter Connection details RS232, typ. settings 9600bps, 8 data, 1 stop, no parity, no flow control For ExMod-RF10 RF and ExMod-RF100 RF versions: Connection: RF distances: Radiated power: Antenna: Bluetooth type setting: provide wireless RS232 interface via Bluetooth 1.2 (2,4GHz) specification (transparent RS232 Interface), Class 2 for ExMod- RF10-2-3, Class 1 for ExMod-RF max. 10m for ExMod-RF (open field) max. 100m for ExMod-RF (open field) Local conditions can affect the RF distances. max. 2W Bluetooth PIN: 0000 External antenna Ex ia (via interface X83), 50Ω impedance, connector SMA standard, extension via appropriated 50Ω coax cable only, max. cable length 1m (3,3ft), use antenna/cable combination whose gain/loss result are max. 2 dbi at external antenna connector X83. Use appropriate pre-mounted antenna/cable approved by Gecma Components GmbH only! RS232 interface, individual bounding programmable, connectable, discoverable General/input interfaces: Charging Interface Ex ia (interface X82) External antenna interface for BT-module Ex ia (interface X83) Reset button/interface for BT-module Ex ia (interface X88) Output interfaces: refer to details for ExMod-1-RS232-3, ExMod-1-RS422i-3 and ExMod-1-RS422e-3 MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B - 5 -

6 For ExMod-5V HP-2-3, ExMod-5V LP-2-3 and ExMod-12V HP-2-3 versions: General/input interfaces: 5V HP Power Interface Ex ia (interface X81) for ExMod-5V HP-2-3 or 5V LP Power Interface Ex ia (interface X81) for ExMod-5V LP-2-3 or 12V HP Power Interface Ex ia (interface X81) for ExMod-12V HP-2-3. Serial data Interface Ex ia (interface X81) Output interfaces: refer to details for ExMod-1-RS232-3, ExMod-1-RS422i-3 and ExMod-1-RS422e-3 For ExMod-1-RS232 RS232-3, 3, ExMod-1-RS422i RS422i-3 and ExMod-1-RS422e RS422e-3 versions: General/input interfaces: Output interfaces: refer to details for ExMod-RF and ExMod-RF versions and ExMod-5V HP-2-3, ExMod-5V LP-2-3 and ExMod- 12V HP-2-3 versions RS232 Ex ia output interface and RS232 Ex e output interface for ExMod-1-RS232-3 or RS422 Ex ia output interface for ExMod-1-RS422i-3 or RS422 Ex e output interface for ExMod-1-RS422e-3 For ExMod-1-2-AC and ExMod-1-2-DC24 versions: Supply: for AC: 100VAC 230VAC (±10%), Hz / 1A for DC24: VDC / 1A Certificates ATEX certification of ExMod-1-2-3: Zone 1 [0] / EPL Gb [Ga] Zone 21 [20] / EPL Db [Da][ ATEX ignition protection Ex II 2(1)G Ex e q [ia IIC] T4 Ex II 2(1)D Ex td [iad] A21 IP64 T130 C Gb Operating temperature (10% to 90% rel. humidity, n.c) Ta: -20 C +60 C (-4 F to 140 F) Ta: -20 C +60 C (-4 F to 140 F) ATEX certification TÜV 08 ATEX 7639 X TÜV 08 ATEX 7639 X IECEx certification of ExMod-1-2-3: (in certificationprocess) Zone 1 [0] / EPL Gb [Ga] Zone 21 [20] / EPL Db [Da] IECEx ignition protection Ex e q [ia IIC] T4 Gb Ex td [iad] A21 I64 T130 C Operating temperature Ta: -20 C +60 C Ta: -20 C +60 C (10% to 90% rel. humidity, n.c) (-4 F to 140 F) (-4 F to 140 F) IECEx certification IECEx TUR 08. XXXX X IECEx TUR 08. XXXX X Further details can be found in the attached license. MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B - 6 -

7 Programming of ExMod-RF10/RF The ExMod-RF10/RF pre programmed by Gecma. The standard setting are the automatic connection to the accessory barcodescanner BCSi-RF10/RF100. In this case the BT-connection of the ExMod-RF10/RF100 connect automatically to the BCSi-RF10/RF100 with the BT-adress listed in the test certificate. Normally no additional settings necessary! Programming options of the ExMod-RF10/RF : 1) You can scan a list of available BT devices in the range of this ExMod-RF10/RF ) You can program the bounding list and order of automatic connection to BT devices (defined by the BT- address) 3) You can reset to factory defaults For programming you have to enter the configurationmode of the ExMod-RF10/RF : Connect the ExMod-RF10/RF via a appropriated serial Interface to a PC. Open a appropriated terminal/communication software (e.g. Hyperterminal at Windows) and connect to your serial interface with the parameter 9600/8/1/no parity. Press the hidden reset button X88 at the ExMod-RF10/RF near the antenna connection with a small appropriated item. Alternative you can connect a button to the intrinsically safe interface X88 pin 2 and pin 3. After pressing reset button or after power up the ExMod-RF10/RF will show you the message in Hyperteminal: +++ Press <CR>,<CR>,<ESC>,<ESC> to enter BlueRS+ configurator +++ Now you have to press the enter enter button two times and then the ESC ESC button two times within 1 second after shown this message. After successfully operation you ll see the message with internal firmware information: BG2a00 V Feb :30:05 # The # identify that you are in the programming mode (during programming mode no other operation possible). All follow commands you have to enter behind the #. You can program as much commands as you want. Please note that you have to save and exit the programming with the commands: save exit All settings/changings valid after save and exit only. MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B - 7 -

8 List of available BT devices To get a list of available BT-devices in the range of this ExMod-RF10/RF100 you have to enter: binq 2 (Please note the space character before the 2 ) Now you ll get a list with all available BT-devices. This will take some seconds. Below you ll find a list with samples: starting inquiry... d01: 0009DD504A43 0x00010C -064 d02:b 001E3B7977EE 0x001F d03: B9E3 0x001F d04: 001E3B7976EE 0x starting name/service discovery... d01: 0009DD504A43 0x00010C -064 Dell PC d02:b B9E3 0x001F GECMA BCSi-RF100 SN: d03: B9E3 0x001F GECMA BCSi-RF100 SN: d04: 001E3B7976EE 0x NOKIA N73 A short description: After starting inquiry... the ExMod-RF10/RF100 list all found devices. After starting name/service discovery... you ll find additional information. D02: list the device number. Here device D02 B B9E3 0x001F00 list that this device bounded already. Means in this case it s not possible to connect to this device. list the BT adress (in this case B9E3) list the BT device type (in this case a uncategorized or serial device) -073 list the signal strength (as lower the value as better the connection) GECMA BCSi-RF100 SN: list the BT device name MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B - 8 -

9 Programming the bounding list and order of automatic connection You can list up to 3 devices which are automatically connected when inside the RF range of the ExMod- RF10/RF100. The ExMod-RF10/RF100 follow the list of order for the connection. Means when he find device 1 (BT-address 1) he connect automatically to device 1. The other devices not connected. When device 1 not available (or leave the RF range) the ExMod-RF10/RF100 connect automatically to the next available listed device. And so on for the other programmed devices. The ExMod-RF10/RF100 allow one connection at same time. Bounding exclusively to device 1 only possible when device 1 listed only and no entry for device 2 and device 3. Programming device 1: Brad= B9E3 Programming device 2: Brad2= B9E4 Programming device 3: Brad3= B9E5 ( B9E3 are a sample for the BT-adress) ( B9E4 are a sample for the BT-adress) ( B9E5 are a sample for the BT-adress) In top shown sample the ExMod-RF10/RF100 connect to BT address B9E3 automatically. When this BT address B9E3 not available (or leave the RF range) the ExMod-RF10/RF100 connect automatically to BT address B9E4 and so on. When you want to connect to one BT device (e.g. BCSi-RF10/RF100) exclusively you have to enter device 1 only. Don t enter any other adress to device 2 or device 3 or enter the address You can show the current status of the particular device list by enter Brad for device 1 or Brad2 for device 2 or Brad3 for device 3 You can delete each particular device by enter the address Example to delete device 3: Brad3= Reset to factory default To set to factory default please enter follow parameters in the list of order. Please note that after reset to factory default no bounding device programmed! Please program a bounding device for proper function. defa=1 br=4 flc=0 cdtr=0 cmds=8 MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B - 9 -

10 Assembly The assembly and the connections of the inputs/outputs cables depend of ExMod models. For the installation plan of each ExMod models, please refer to the following attached drawings: # : Installation plan of ExMod-RF10 or RF100-RS422i-3 # : Installation plan of ExMod-RF10 or RF100-RS422e-3 # : Installation plan of ExMod-RF10 or RF100-RS232-3 # : Installation plan of ExMod-5VHP or 5VLP or 12VHP-2-RS422i # : Installation plan of ExMod-5VHP or 5VLP or 12VHP-2-RS422e # : Installation plan of ExMod-5VHP or 5VLP or 12VHP-2-RS232 MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B

11 Connections details For all Ex Mod-1-2-3: Supply voltage in: X80, Terminal 1-2, Increased safety: Contact 1: +U / L Contact 2: GND / N 2 x (0,2-2,5)mm² / (24AWG-14AWG), single- and multi-strand Strip length 6-7mm (0,26in) Um max. 250V / 1500A Cable gland M16 for round cable, Outer cable diameter 5,5...10mm (0,22...0,39 ) For ExMod-1-2-AC *: Utyp 100V 230V (±10%) Ityp 1A Um 250V Ik 1500A For ExMod-1-2-DC24 *: Utyp 20V 30V (±10%) Ityp 1A Um 250V Ik 1500A Supply voltage out: X80, Terminal 3-4, Increased safety: Contact 3: +U / L Contact 4: GND / N 2 x (0,2-2,5)mm² / (24AWG-14AWG), single- and multi-strand Strip length 6-7mm (0,26in) Cable gland M16 for round cable, Outer cable diameter 5,5...10mm (0,22...0,39 ) Output current max. 3A. MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B

12 For ExMod-RF10 or RF : Charging Interface: X82, Terminal 1-2, Intrinsically safe ia: Contact 1: +U Contact 2: GND 2 x (0,2-2,5)mm² / (24AWG-14AWG), single- and multi-strand Strip length 6-7mm (0,26in) Cable gland M12 for round cable, Outer cable diameter 4...7mm (0,16...0,28 ) Ui 10,8 V Ii not important Pi 6,6 W Li negligible Ci negligible Uo 10,8 V Io 553 ma Po 2,54 W Lo 20 uh Co 2 uf Recommended max. cable length 5m (16,4ft) Pay attention to the values listed in corresponding standards. Antenna interface: X83-1 to 2, Intrinsically safe ia: Contact 1: antenna signal Contact 2: GND connector SMA standard, 50Ω impedance Ui 5,5 V Ii not important Pi 1,2 W Li 0,05 uh Ci 45 uf Uo 5,4 V Io 300 ma Po 1,2 W Lo 1 uh Co 10 uf Extension via appropriated 50Ω coax cable only, use antenna/cable combination that gain/loss result are max. 2 dbi at external antenna connector X83. Use from Gecma Components GmbH appropriated and approved pre mounted antenna /cable only! Recommended max. cable length 1m (3,3ft). Pay attention to the values listed in corresponding standards. MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B

13 Reset interface: X88-1 to 4, Intrinsically safe ia: Contact 1: NC Contact 2: Res1 Contact 3: Res2 Contact 4: NC Recommended connector: Phoenix MSTB2,5/4-ST-5,08 BU Ui 5,5 V Ii not important Pi not important Li negligible Ci negligible Uo 5,4 V Io 168 ma Po 226 mw Lo 1 mh Co 0,5 uf Recommended max. cable length 1000m (3300ft) Pay attention to the values listed in corresponding standards. For ExMod-5V HP-2-3: Power/data interface: X81, Terminal 1-5, Intrinsically safe ia: 5 x (0,2-2,5)mm² / (24AWG-14AWG), single- and multi-strand Strip length 6-7mm (0,26in) Cable gland M12 for round cable, Outer cable diameter 4...7mm (0,16...0,28 ) When the distance between the supply line (X81-1 and 2) and the data lines (X81-3 to X81-5) comply to the clearance / creepage distances in the standard IEC/EN : Supply voltage: X and 2, 2 Intrinsically safe ia: Contact 1: +Ui Contact 2: GND Ui 5,5 V Ii not important Pi not important Li negligible Ci negligible Uo 5,4 V Io 1,43 A Po 5,7 W Lo 1uH Co 65 uf MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B

14 Data Lines: X81-3 to X81-5, Intrinsically safe ia: Contact 3: RXD (input) Contact 4: TXD (output) Contact 5: GND Ui 25 V Ii not important Pi not important Li negligible Ci negligible Uo 5,4 V Io 12 ma Po 16 mw Lo 2 mh Co 65 uf Recommended max. cable length 5m (16,4ft). Pay attention to the values listed in corresponding standards. When the distance between the supply line (X81-1 and 2) and the data lines (X81-3 to X81-5) not comply to the clearance / creepage distances in the standard IEC/EN : Supply voltage / Data: X to 5, 5 Intrinsically safe ia: Contact 1: +Ui Contact 2: GND Contact 3: RXD (input) Contact 4: TXD (output) Contact 5: GND Ui 5,5 V Ii not important Pi not important Li negligible Ci negligible Uo 5,4 V Io 1,43 A Po 5,7 W Lo 1 uh Co 50 uf Recommended max. cable length 5m (16,4ft). Pay attention to the values listed in corresponding standards. MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B

15 For ExMod-5V LP-2-3: Power/data interface: X81, Terminal 1-5, Intrinsically safe ia: 5 x (0,2-2,5)mm² / (24AWG-14AWG), single- and multi-strand Strip length 6-7mm (0,26in) Cable gland M12 for round cable, Outer cable diameter 4...7mm (0,16...0,28 ) When the distance between the supply line (X81-1 and 2) and the data lines (X81-3 to X81-5) comply to the clearance / creepage distances in the standard IEC/EN : Supply voltage: X and 2, 2 Intrinsically safe ia: Contact 1: +Ui Contact 2: GND Ui 5,5 V Ii not important Pi not important Li negligible Ci negligible Uo 5,4 V Io 424 ma Po 1,15 W Lo 1 uh Co 65 uf Data Lines: X81-3 to X81-5, Intrinsically safe ia: Contact 3: RXD (input) Contact 4: TXD (output) Contact 5: GND Ui 25 V Ii not important Pi not important Li negligible Ci negligible Uo 5,4 V Io 12 ma Po 16 mw Lo 2 mh Co 65 uf Recommended max. cable length 5m (16,4ft). Pay attention to the values listed in corresponding standards. MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B

16 When the distance between the supply line (X81-1 and 2) and the data lines (X81-3 to X81-5) not comply to the clearance / creepage distances in the standard IEC/EN : Supply voltage / Data: X to 5, 5 Intrinsically safe ia: Contact 1: +Ui Contact 2: GND Contact 3: RXD (input) Contact 4: TXD (output) Contact 5: GND Ui 5,5 V Ii not important Pi not important Li negligible Ci negligible Uo 5,4 V Io 436 ma Po 1,1 W Lo 1 uh Co 65 uf Recommended max. cable length 5m (16,4ft). Pay attention to the values listed in corresponding standards. For ExMod-12V HP-2-3: Power/data interface: X81, Terminal 1-5, Intrinsically safe ia: 5 x (0,2-2,5)mm² / (24AWG-14AWG), single- and multi-strand Strip length 6-7mm (0,26in) Cable gland M12 for round cable, Outer cable diameter 4...7mm (0,16...0,28 ) When the distance between the supply line (X81-1 and 2) and the data lines (X81-3 to X81-5) comply to the clearance / creepage distances in the standard IEC/EN : Supply voltage: X and 2, 2 Intrinsically safe ia: Contact 1: +Ui Contact 2: GND Ui 12,5 V Ii not important Pi not important Li negligible Ci negligible Uo 12,4 V Io 514 ma Po 2,37 W Lo 10 uh Co 1,2 uf MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B

17 Data Lines: X81-3 to X81-5, Intrinsically safe ia: Contact 3: RXD (input) Contact 4: TXD (output) Contact 5: GND Ui 25 V Ii not important Pi not important Li negligible Ci negligible Uo 5,4 V Io 12 ma Po 16 mw Lo 2 mh Co 65 uf Recommended max. cable length 5m (16,4ft). Pay attention to the values listed in corresponding standards. When the distance between the supply line (X81-1 and 2) and the data lines (X81-3 to X81-5) not comply to the clearance / creepage distances in the standard IEC/EN : Supply voltage / Data: X to 5, 5 Intrinsically safe ia: Contact 1: +Ui Contact 2: GND Contact 3: RXD (input) Contact 4: TXD (output) Contact 5: GND Ui 12,5 V Ii not important Pi not important Li negligible Ci negligible Uo 12,4 V Io 526 ma Po 2,38 mw Lo 10 uh Co 1,2 uf Recommended max. cable length 5m (16,4ft). Pay attention to the values listed in corresponding standards. MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B

18 For ExMod-1-RS232 RS232-3: 3: RS232i Interface: X84, Terminal 1 to 3, Intrinsically safe ia: Contact 1: RXD (input) Contact 2: TXD (output) Contact 3: GND 3 x (0,2-2,5)mm² / (24AWG-14AWG), single- and multi-strand Strip length 6-7mm (0,26in) Cable gland M12 for round cable, Outer cable diameter 4...7mm (0,16...0,28 ) Ui 25 V Ii not important Pi not important Li negligible Ci negligible Uo 5,4 V Io 12 ma Po 16 mw Lo 200 mh Co 0,5 uf Recommended max. cable length 15m (50ft). Pay attention to the values listed in corresponding standards. RS232e Interface: X85, Terminal 1 to 3, Increased safety: Contact 1: RXD (input) Contact 2: TXD (output) Contact 3: GND 3 x (0,2-2,5)mm² / (24AWG-14AWG), single- and multi-strand Um max. 250V / 1500A Cable gland M16 for round cable, Outer cable diameter 5,5...10mm (0,22...0,39 ) Utyp 30V Ityp 2A Um 250V Ik 1500A Recommended max. cable length 15m (50ft). Pay attention to the values listed in corresponding standards. MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B

19 For ExMod-1-RS422i RS422i-3: RS422i Interface: X86, Terminal 1 to 5, Intrinsically safe ia: Contact 1: RX- i Contact 2: RX+ i Contact 3: TX- i Contact 4: TX+ i Contact 5: GND 5 x (0,2-2,5)mm² / (24AWG-14AWG), single- and multi-strand Strip length 6-7mm (0,26in) Cable gland M12 for round cable, Outer cable diameter 4...7mm (0,16...0,28 ) Ui 8,2V Ii not important Pi not important Li negligible Ci negligible Uo 5,4 V Io 64 ma Po 253 mw Lo 9 mh Co 0,5 uf Recommended max. cable length 1000m (3300ft) Pay attention to the values listed in corresponding standards. RS422e Interface: X87, Terminal 1 to 5, Increased safety: Contact 1: RX- e Contact 2: RX+ e Contact 3: TX- e Contact 4: TX+ e Contact 5: GND 5 x (0,2-2,5)mm² / (24AWG-14AWG), single- and multi-strand Um max. 250V / 1500A Cable gland M16 for round cable, Outer cable diameter 5,5...10mm (0,22...0,39 ) Utyp 30V Ityp 2A Um 250V Ik 1500A Recommended max. cable length 1000m (3300ft) Pay attention to the values listed in corresponding standards. MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B

20 Terminal Connections Ex e supply voltage interface X80: Connection Significance VAC(max) 24VDC variant AC variant Supplycircuit Supplycircuit X80-1 L +24V DC Supplycircuit Supplycircuit X80-2 N 0V DC Outputcircuit Outputcircuit X80-3 L +24V DC Outputcircuit Outputcircuit X80-4 N 0V DC X80-5 PE PE X80-6 PE PE The device are supplied via the Supply circuit. The Output circuit are integrated to supply optional other devices (max. 3A). The Supply circuit and the Output circuit are connected parallel. Ex i charging interface X82: Connection Significance X82-1 +U X82-2 GND Ex i serial interface RS232i with power X81: Connection Significance X81-1 +U X81-2 GND X81-3 RxDi (Input) X81-4 TxDi (Output) X81-5 GND Ex i serial interface RS232i X84: Ex e serial interface RS232e X85: Connection Significance X84-1 RxDi (Input) X84-2 TxDi (Output) X84-3 GND Connection Significance X85-1 RxD (Input) X85-2 TxD (Output) X85-3 GND MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B

21 Ex i interface RS422i X86: Connection Significance X86-1 Rx-i X86-2 Rx+i X86-3 Tx-i X86-4 Tx+i X86-5 GND Ex e interface RS422e X87: Connection Significance X87-1 Rx-e X87-2 Rx+e X87-3 Tx-e X87-4 Tx+e X87-5 GND Ex i antenna interface X83: Connection Significance X83-1 Antenna signal X83-2 GND Ex i Reset interface X88: Connection Significance X88-1 NC X88-2 RES1 X88-3 RES2 X88-4 NC Further details can be found in attached installation plan drawings of different variants. MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B

22 Safety Instructions General Safety Instructions The instructions stated in this chapter are to be followed accurately to ensure a safe and reliable operation. The license and the special conditions included in it are to be observed. Follow the national safety regulations and the accident prevention regulations. The installation is only to be performed by specialists. These specialist must be familiar with the characteristics of explosion-endangered facilities. Incorrect or inadmissible application as well as non-observance of the instructions of this operating manual make the guarantee void. For ExMod-RF10/RF only: The BT-modul has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and with RSS-210 of IndustryCanada as LMO. This device contains transmitter with FCCID: RFR- C11G2, IC ID: 4957A- C11G2. The BT-modul is a qualified design according to the Bluetooth Qualification Program Reference Document (PRD) V2.0. The Qualified Design ID (QDID) is: B Only use this device for the approved purpose. Conversions and modifications to the device are inadmissible. The housing is only to be opened by the company Gecma Components GmbH. The first two digits of the serial number located at the nameplate identify the year of manufacture. Assembly The national assembly and installation regulations are to be observed. The generally accepted rules of engineering are to be observed. The entire equipment is to be connected and operated correctly and properly according to the applicable standards, guidelines and installation instructions. The housing is to be grounded via grounding equipment. Grounding must be effected with a core cross section of at least 4mm². Shielded cables are recommended for use in combination with this device. Connect the device only when the Ex e and Ex i circuits are complete de-energized. Do not open the terminal enclosure when the device is powered and live. Ensure the power supply is isolated. The cable diameter has to comply to the specification of the terminals. The outer diameter of the cables has to comply to the specification of the cable glands. Tighten the Cable glands according to the rules. Seal not used cable glands. The cable glands of the Ex e terminal enclosure have to comply to the national standards and have to be interchanged if necessary. Ensure that between the ExMod * and the accesoiry devices equipotential bonding has to be established. The device is only to be connected in a de-energized condition. Isolate all circuits, wait 2 min. before opening the accessory Ex e CONNECTION BOX! If the device in a dust atmosphere is to be replaced, the device and/or the housing, in which the device is installed, is to be de-energized first and if necessary cooled according to the regulations. Before opening the device and/or housing and during period in which the device and/or the housing is open, the environment of the device and/or housing has to be kept dust-free to such an extent that no dust can enter the interior of the housing. When installing new components observe that all seals are in a flawless condition and function properly. Before putting the device into operation make sure that the device has been installed as prescribed and that the device and its wiring are not damaged. If the power supply of the device is not intrinsically safe, the license will become void and it must not be operated as an intrinsically safe device. If the device was operated intrinsically safely with a low level of international protection (e.g. ib), it must not be operated afterwards in applications for a higher level of international protection (e.g. ia). Only permanently laid cables may be entered. The use must guarantee suitable clamping The cable glands, if visible, may be used only in places where they are protected against the influence of mechanical danger. In the case that the Ex e terminals X80-1 and X80-2 are solely connected the short current protection must be suitable for the diameter of the connected cable. If in addition the power is looped through the Ex-e terminals X80-3 and X80-4 the maximum current must be limited to a value lower or equal than 5A. The maximum short current at the place of installation must not exceed 1500 A. Operation The device is only to be operated in an undamaged and clean condition. If the device has suffered any damages which might affect the international protection (e.g. cracks, holes or broken components) it must be taken out of service immediately. The device can only be put into operation again after the defect components have been exchanged. When the device is damaged, do not touch it any longer! Risk of injury! If the device is to be used in a dust atmosphere dust layers >5mm have to be removed. In the event of non-observance & non-compliance the stipulated explosion protection cannot be guaranteed and/or the guarantee will become void! Modifications require the written approval by the company GeCma Components GmbH. MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B

23 General Instructions Before starting the assembly read the entire operating manual! In cases of doubt (in the form of mistranslation) the German operating manual is to be applied. We do not assume liability for misprints and errors in this operating manual. The housings shall only be opened by personnel of Gecma Components GmbH. Should you have any questions or suggestions please feel free to contact us any time: GeCma Components GmbH Heisenbergstraße D Kerpen Tel.: +49 (0)22 37 / Fax: +49 (0)22 37 / mailto:info@gecma.com Technical progress The manufacturer reserves the right to adjust all technical data without special announcement according to the technical progress. Repair work, hazardous material The description of the respective fault(s) is in any case to be included with the devices which are sent to GeCma Components GmbH for repair. The following measures are to be taken before sending a device in for repair: Please remove the entire adhering medium residue. Pay special attention to sealing grooves and gaps which might contain medium residue. We have to ask you to refrain from sending the device back if it is impossible for you to definitely guarantee that all health-endangering material has completely been removed. Costs which arise due to inadequate cleaning of the device for a potential disposal or for personal injury (cauterization, etc.) will be charged to the proprietor of the device. Used trademarks AT, IBM and PS/2 are registered trademarks of the International Business Machines Corporation. Bluetooth is a registered trademark of Bluetooth SIG, Inc. Microsoft, Windows and Windows NT are registered trademarks of Microsoft Corporation. All other trademarks mentioned and depicted in the text are trademarks of the respective owners and are recognized as registered. Drawings and certifications MANUAL EXMOD EX-MODULE BASE STATION REV 1.6 EN.DOC N.B

24

25

26

27

28

29

30

31

32

33

34

35

Manual Mouse Module CHALLENGER Mi-PS2 / Mi-PS2-B

Manual Mouse Module CHALLENGER Mi-PS2 / Mi-PS2-B Manual Mouse Module CHALLENGER Mi-PS2 / Mi-PS2-B GECMA.COMPONENTS GMBH WWW.GECMA.COM TEL. +49 2237 6996-0 FAX -99 MANUAL MI_PS2_B REV 1.3 EN.DOC 31.01.07 A. J. 1 List of contents List of contents... 2

More information

Operating Manual Touchpad CHALLENGER TPi

Operating Manual Touchpad CHALLENGER TPi Operating Manual Touchpad CHALLENGER TPi GECMA COMPONENTS GMBH WWW.GECMA.COM TEL. +49 2237 6996-0 FAX. +99 MANUAL TPI REV 1.4 EN.DOC 31.01.07 A.J. 1 List of Contents List of Contents... 2 Introduction...

More information

Operating Manual Panel PC EXPLORER 15i EXPLORER 18i

Operating Manual Panel PC EXPLORER 15i EXPLORER 18i Operating Manual Panel PC EXPLORER 15i EXPLORER 18i Doc: 60000206 GECMA COMPONENTES GMBH WWW.GECMA.COM TEL. +49 2237 6996-0 FAX. -99 MANUAL EXPLORER REV 1.10 EN.DOC 13.05.08 A.J. 1 Contents Contents.........

More information

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x 1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical

More information

Operating Manual BCSi-1 *

Operating Manual BCSi-1 * Operating Manual BCSi-1 * Barcode scanner Doc.Nr.:60000340 MANUAL BCSI-1 REV 1.7 EN.DOC 19.12.08 A.J. - 1 - List of Contents List of Contents...2 Introduction...3 BCSi-1 * models available...4 Technical

More information

Installation & Operation Manual

Installation & Operation Manual Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas

More information

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015 Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in

More information

Intrinsically safe batch controller Batching Master 110i

Intrinsically safe batch controller Batching Master 110i Intrinsically safe batch controller Batching Master 110i Installation Guide BVS 04 AT E 172 Revision 12.2 IBS BatchControl GmbH Im Sträßchen 2-4 Tel.: ++49 2441 9199 801 53925 Kall Fax.: ++49 2441 9199

More information

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni) Data sheet 302040_en MTP300i-SIL-K Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni) Properties 2-wire temperature transmitter for DIN rails Galvanic isolated TC-input with cold-junction compensation

More information

The 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel.

The 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel. February 23, 2018 Annexe to: IECEx CML 15.0097X Issue 4 Applicant: Apparatus: HMI Elements Limited 470-Z1 Module Description of Equipment The 470-Z1 is a mains supplied, transportable hazardous area

More information

Installation Instruction. HART Add-On Module

Installation Instruction. HART Add-On Module - Translation Typs 17-A1Z0-0005, B7-A2Z0-0033 and G7-A0Z0-0007 Version for: Non hazardous areas ATEX/IECEx Zone 1 and Zone 2 UL Class I Division 1 and Division 2 Document No.: B1-A2Z0-7N0001 / 400570 Revision

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC MS96-11EX0-R/230VAC ATEX category II (1) G, Ex Zone 0 ATEX category II (1) D, Ex Zone 20 single-channel signal processor MS96 for connection of an intrinsically safe flow control sensor in zone 0 adjustment

More information

Smart Wireless THUM Adapter

Smart Wireless THUM Adapter Quick Installation Guide Smart Wireless THUM Adapter Smart Wireless THUM Adapter Start Wireless Considerations Step 1: Physical Installation Step 2: Verify Operation Reference Information Product Certifications

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99

More information

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

Safety instructions. IECEx TUN Ex ia IIC T6 Gb Safety instructions ÜSB62-36G.C_* and ÜSB62-30W.C_* IECEx TUN 07.0002 Ex [ia Ga] IIC T6 Gb Ex ia IIC T6 Gb 0044 39878 Content 1 Area of applicability 3 2 General 3 3 Electrical data 3 3.1 Application conditions

More information

Zener Barriers Bulletin 937Z

Zener Barriers Bulletin 937Z Technical Data Zener Barriers Bulletin 937Z Topic Page Introduction 2 Mounting 2 Housing 3 Operating Principle 3 Specifications 6 Introduction Allen-Bradley Zener barriers are a cost-effective solution

More information

Installation & Operation Manual

Installation & Operation Manual Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas

More information

Emergency power supply NV2.1-12iaE

Emergency power supply NV2.1-12iaE Ordering Data Designation Type Item no. 372 100 04 AX Supply of consumers even in case of failure or shutdown of the input / charging current circuit NiCd as energy store Intrinsically safe input voltage

More information

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505 Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating

More information

Safety instructions Overvoltage protection B81-35

Safety instructions Overvoltage protection B81-35 Safety instructions Overvoltage protection B81-35 IECEx BVS 15.0084X Intrinsic safety Document ID: 51001 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 5 4 Application

More information

Operating Instructions

Operating Instructions Operating Instructions KBDi-DS102W-xxx R. STAHL HMI Systems GmbH Adolf-Grimme-Allee 8 D 50829 Köln Operating Instructions Version: 01.00.05 Issue date: 19.09.2018 Disclaimer Disclaimer Publisher and copyright

More information

Barriers. EB3N Discrete Input Barrier with Redundant Output

Barriers. EB3N Discrete Input Barrier with Redundant Output EB3N Discrete Input Barrier with Redundant Output s Build a safety system in an explosive atmosphere. Key features: Safety Performance Performance level e Category 4 [Exia] II C Ensures safety and machine

More information

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

Inductive sensor with analog output BI15-M30-LI-EXI

Inductive sensor with analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection

More information

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F 4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to

More information

MINI MCR-SL-PT100-UI-200

MINI MCR-SL-PT100-UI-200 Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is

More information

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Electrical, explosion proof transducers only connectable to ExPro-B... thermostats and humidistats 24 VAC/DC

More information

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W Title INTRINSICALLY SAFE Ex ia PSU TYPE AC36W USER MANUAL Document Number 66-184-12 Issue 10 10 Update new logo and address 2017.10.18 CW CW PC 09 Added Um as 265V, Io up to 3.3A & IIB data 2017.08.21

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)

More information

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description Active resistance thermometer measuring transducer Data sheet 099_en_06 PHOENIX CONTACT 0-0- Description The 6. mm wide MINI MCR-SL-PT00-UI-... is a configurable, -way isolated temperature measuring transducer.

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

Operating Instructions

Operating Instructions Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on

More information

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern Operating Manual / IEC Explosion-Proofed Junction Boxes, Polyester Wallücker Bahndamm 7 DE- 32278 Kirchlengern Tel.: +49 5223 49107-0 Fax: +49 5223 49107-28 info@multi-box.com www.multi-box.com Contents

More information

Operating and monitoring systems Thin Client SERIES 500 Device platform EAGLE PM ET-556-TX

Operating and monitoring systems Thin Client SERIES 500 Device platform EAGLE PM ET-556-TX Thin Client for panel mounting, 19" display, 1280 x 1024 pixels Zone 1, 2, 21, 22, can be installed in hazardous areas without additional enclosure All-round degree of protection, resistive foil touch

More information

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 1 Series 9475/ www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

VISY. Technical Documentation. VISY-Command (VI-4) Version: 6 Edition: Art. no.:

VISY. Technical Documentation. VISY-Command (VI-4) Version: 6 Edition: Art. no.: Technical Documentation VISY VISY-Command (VI-4) Version: 6 Edition: 2017-09 Art. no.: 207184 FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg Tel.: +49 / 40 / 39 82 07-0 Fax: +49 / 40 / 390 63 39 Table

More information

Lighting Controls and Connectivity basicdim. basicdim Wireless Passive Module Wireless module for basicdim

Lighting Controls and Connectivity basicdim. basicdim Wireless Passive Module Wireless module for basicdim Wireless Passive Module Wireless module for Product description Wireless controllable with a Android / ios smart device No need for an external gateway device Forms automatically a wireless communication

More information

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions , Equipment protection fuse with Ex mb II C Gb approval Geräteschutzsicherung mit Zulassung Ex mb II C Gb Fusible de protection d appareil avec homologation Ex mb II C Gb Example / Beispiel / Exemple:

More information

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless

More information

MANUAL Surge Protectors

MANUAL Surge Protectors PROCESS AUTOMATION MANUAL Surge Protectors DP-LBF-I1.36.DE and DP-LBF- I1.36.IE With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

Rosemount 248 Wireless Temperature Transmitter

Rosemount 248 Wireless Temperature Transmitter Quick Installation Guide Rosemount 248 Wireless Rosemount 248 Wireless Temperature Transmitter Start Wireless Considerations Step 1: Physical Installation Step 2: Verify Operation Reference Information

More information

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical

More information

DR7100 SERIES Supplementary instructions

DR7100 SERIES Supplementary instructions DR700 SERIES Supplementary instructions Guided Radar (TDR) Level Instrument for 2-wire control systems Supplementary Instructions for ATEX applications AMETEK Drexelbrook - EDO -0-2, DR700-LM ATEX, Issue

More information

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions Device with II 2G EX i approval Geräte mit II 2G EX i Zulassung Appareils avec mode de protection II 2G EX i Example / Beispiel / Exemple Type 6106 Operating Instructions Bedienungsanleitung Manuel d utilisation

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

SMARTLINE RM76 Supplementary instructions

SMARTLINE RM76 Supplementary instructions SMARTLINE RM76 Supplementary instructions 2-wire / Guided Radar (TDR) Level Meter Supplementary Instructions for ATEX applications CONTENTS SMARTLINE RM76 1 General safety information 5 1.1 Scope of the

More information

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller), Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

Speaking Station LV30

Speaking Station LV30 Speaking Station LV30 Ordering data Designation Type Item no. Speaking station with cable entries LV 30 300 0 AX Speaking station with plug connectors (socket / socket) Speaking station with plug connectors

More information

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU)

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU) Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU) Rev. 2 September 2012 Part No. 4417552 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax :

More information

CPCI-PS24 24V-Power Supply

CPCI-PS24 24V-Power Supply 24V-Power Supply Hardware Manual to Product I.2301.21 esd electronic system design gmbh Vahrenwalder Str. 207 30165 Hannover Germany http://www.esd.eu Phone: +49 (0) 511 3 72 98-0 Fax: +49 (0) 511 3 72

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 05/2007 Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007

More information

Instruction Manual. T3110 T3110L T3110Ex

Instruction Manual. T3110 T3110L T3110Ex www.cometsystem.cz Instruction Manual T3110 T3110L T3110Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with 4-20 ma outputs Copyright: COMET System,

More information

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32 PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32 With regard to the supply of products, the current issue of the following document is applicable: The General Terms

More information

SUBCON-PLUS-PROFIB...

SUBCON-PLUS-PROFIB... Fast connector for PROFIBUS systems Data sheet 101610_en_10 PHOENIX CONTACT 2017-03-27 1 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12

More information

5 Fieldbus Technology

5 Fieldbus Technology 5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically

More information

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter Installation, Operation & Maintenance Sheet Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter > Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2

More information

Conveyor Belt Alignment Switches from IDEM

Conveyor Belt Alignment Switches from IDEM Conveyor Belt Alignment Switches from IDEM Data Sheet Die-Cast Models Python Line Series Stainless Steel Models Using Conveyor Belt Alignment Switches Application: Conveyor Belt Alignment switches are

More information

Product manual plug, sockets and coupler 16 A.- Z0251

Product manual plug, sockets and coupler 16 A.- Z0251 Product manual plug, sockets and coupler 16 A.- Z0251 INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these

More information

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX Panel PC for panel- mounting, quad core ATOM E3845 15" display, 1024 x 768 pixels with resistive foil touch screen 8 function keys Zone 2, 22 und Division 2, can be installed in hazardous areas without

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

C9900-P208 and C9900-P209

C9900-P208 and C9900-P209 Installation and Operating instructions for C9900-P208 and C9900-P209 Power Supply Units Version: 1.5 Date: 2012-02-22 Table of contents Table of contents 1. Foreword 2 Notes on the Documentation 2 Liability

More information

SIWAREX JB stainless steel with ATEX. certificate. Weighing systems. SIWAREX JB stainless steel with ATEX certificate.

SIWAREX JB stainless steel with ATEX. certificate. Weighing systems. SIWAREX JB stainless steel with ATEX certificate. SIWAREX JB stainless steel with ATEX certificate Introduction 1 Notes on handling the product 2 Weighing systems SIWAREX JB stainless steel with ATEX certificate Compact Operating Instructions Description

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions DUAL DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL

More information

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5 EN/2018-03-14 Design and specifications subject to change without notice Operating instructions for temperature sensor English page 1...5 Field of application CombiTemp is a temperature sensor, based on

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM ET-436-TX

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM ET-436-TX Panel PC for panel- mounting, quad core ATOM E3845 15" display, 1024 x 768 pixels with resistive foil touch screen 8 function keys Zone 1, 2, 21, 22 und Division 2, can be installed in hazardous areas

More information

How to calculate an Intrinsically Safe loop approval.

How to calculate an Intrinsically Safe loop approval. MIE TALK - October 2016 How to calculate an Intrinsically Safe loop approval. EXPLOSIVE ATMOSPHERES Compile by: Gary Friend BSc PrEng, CEng MIET, Sales DirectorExtech Safety Systems (MTL, Beka Associates,

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

Type Quickstart (from device Version 2)

Type Quickstart (from device Version 2) Type 8022 Flow Transmitter / Pulse divider Durchflusstransmitter / Impulsteiler Transmetteur de débit / Diviseur d impulsions We reserve the right to make technical changes without notice. Technische Änderungen

More information

MINI MCR-SL-CVS NC

MINI MCR-SL-CVS NC Constant voltage source Data sheet 105264_en_01 PHOENIX CONTACT 2013-04-03 1 Description Configurable constant voltage source for generating highprecision constant voltages. The voltage supply is also

More information

General Specifications

General Specifications General Specifications Field Wireless Communication Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Communication Module. This product is based on the industrial

More information

MINI MCR-SL-PT100-UI(-SP)(-NC)

MINI MCR-SL-PT100-UI(-SP)(-NC) Configurable Temperature Transducer for PT100 Data Sheet 04/2005 Functions MINI MCR-SL-PT100-UI(-SP)(-NC) is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection

More information

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min. Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.4) Installation min. 1 000 (39) is a 2-wire 2 GHz pulse radar level transmitter for continuous monitoring of solids in storage vessels

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions BlueGuard FE Bluetooth Enabled Access Control MODEL BG-FE Operating Instructions CAUTION AND SAFETY INFORMATION IMPORTANT: If the equipment is used in a manner not specified in this manual, the protection

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0. LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx BKI 07.0001X issue No.:1

More information

RAD-WHG/WLAN-XD. WirelessHART gateway with integrated WLAN (802.11b/g) INTERFACE Data Sheet 2720_en_C. 2 Features. 1 Description

RAD-WHG/WLAN-XD. WirelessHART gateway with integrated WLAN (802.11b/g) INTERFACE Data Sheet 2720_en_C. 2 Features. 1 Description WirelessHART gateway with integrated WLAN (802.11b/g) INTERFACE Data Sheet 2720_en_C 1 Description PHOENIX CONTACT 2011-06-07 2 Features The RAD-WHG/WLAN-XD is a WirelessHART gateway with integrated 802.11b/g

More information

C9900-P223 and C9900-P224

C9900-P223 and C9900-P224 Installation and Operating instructions for C9900-P223 and C9900-P224 Power Supply Units Version: 1.2 Date: 2012-02-22 Table of contents Table of contents 1. Foreword 2 Notes on the Documentation 2 Liability

More information

Inductive sensor BI5-EM18-Y1X-H1141

Inductive sensor BI5-EM18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.

More information

Interface and Supply module. IPC 3x0i / PSC 3x0i

Interface and Supply module. IPC 3x0i / PSC 3x0i Interface and Supply module IPC 3x0i / PSC 3x0i Installation Guide Version 10 IBS BatchControl GmbH Im Sträßchen 2 4 Tel.: +49 2241 9199801 53925 Kall Fax.: +49 2241 9199871 Germany www.ibs-batchcontrol.com

More information