1 Versatile Access Power and Integration Enclosures Installation Guide Models Include: Trove2M2 - Trove2 enclosure with / backplane TM2 - / backplane only Trove2V2 - Trove2 enclosure with / backplane TV2 - / backplane only TMV2 - or optional door backplane Rev More than just power.
2 Overview: Trove2M2 or Trove2V2 accommodates various combinations of or boards with or without power supplies and accessories for access systems. Specifications: 19 Gauge grey enclosure with ample knockouts for convenient access. Enclosure Dimensions (H x W x D): x x 6.5 (692.15mm x mm x 165.1mm) Trove2M2 - Trove2 enclosure with TM2 / backplane. Includes: tamper switch, cam lock, lock nuts and mounting hardware. Trove2M2 accommodates a combination of the following: Two (2) eflow3nb, eflow4nb, eflow6nb, eflow102nb or eflow104nb. Four (4) ACM4(CB), ACM8(CB), MOM5, PD4UL(CB), PD8UL(CB). Six (6) MR16IN, MR16OUT. Six (6) EP2500 or. Five (5) MR51e. Two (2) MR50. Trove2V2 - Trove2 enclosure with TV2 / backplane. Includes: tamper switch, cam lock, lock nuts and mounting hardware. Trove2V2 accommodates a combination of the following: Two (2) eflow3nb, eflow4nb, eflow6nb, eflow102nb or eflow104nb. Four (4) ACM4(CB), ACM8(CB), MOM5, PD4UL(CB), PD8UL(CB). Six (6) V1000 or V2000. Backplanes Only: TM2 - / backplane only. Includes: lock nuts and mounting hardware. TV2 - / backplane only. Includes: lock nuts and mounting hardware. Optional Door Backplane: TMV2 - or door backplane only. Includes: lock nuts and mounting hardware. Trove2M2, Trove2V2 Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. 1. Remove backplane from enclosure. Do not discard hardware. 2. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure s upper keyholes over the three upper screws, level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure s upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 10). 3. Mount UL Listed tamper switch (included) (Ademco model 112 or equivalent) at the top of the enclosure. Slide the tamper switch bracket onto the edge of the enclosure approximately 2 from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure. Fig Mount // boards to backplane, refer to pages Hardware: Male/Female Standoff Standoff (Metal or Nylon) 5/16 Pan Head Screw 7/8 Pan Head Screw Lock Nut Honeywell model # 112 Tamper Switch or equivalent (provided) Enclosure to Access Control Panel or U.L. Listed Reporting Device Edge of Enclosure // Enclosure
3 TM2: Configuration of Power Supply and/or Boards 1. Fasten standoffs (provided) to pems that match the hole pattern for Power Supply/Chargers or boards (Fig. 2, pg. 3). Use male/female nylon standoffs for the upper two mounting holes in the board. Use metal standoffs for the bottom mounting holes to provide sufficient grounding for the board. 2. Affix boards to standoffs (Fig. 2, pg. 3) by pressing down the upper mounting holes onto nylon standoffs. Use provided mounting screws to affix the lower mounting holes. Make sure that boards are locked onto standoffs. 3. Fasten backplane to Trove2 enclosure utilizing lock nuts (provided). Fig. 2 Power Supply or Metal Standoff Placement Power Supply or Metal Standoff Placement // Enclosure - 3 -
4 TM2: Configuration of Boards 1. Fasten standoffs (provided) to pems that match the hole pattern for MR16IN or MR16OUT (Fig. 3, pg. 4). Use male/female nylon standoffs only. 2. Affix boards to standoffs (Fig. 3, pg. 4) by pressing down the mounting holes onto nylon standoffs. Make sure that boards are locked onto standoffs. 3. Fasten backplane to Trove2 enclosure utilizing lock nuts (provided). Fig // Enclosure
5 TM2: Configuration of Boards (cont d) 1. Fasten standoffs (provided) to pems that match the hole pattern for EP2500 or (Fig. 4, pg. 5). Use male/female nylon standoffs only. 2. Affix boards to standoffs (Fig. 4, pg. 5) by pressing down the mounting holes onto nylon standoffs. Make sure that boards are locked onto standoffs. 3. Fasten backplane to Trove2 enclosure utilizing lock nuts (provided). Fig. 4 // Enclosure - 5 -
6 TM2: Configuration of Boards (cont d) 1. Fasten standoffs (provided) to pems that match the hole pattern for EP1501 or MR51e (Fig. 5, pg. 6). Use male/female nylon standoffs only. 2. Affix boards to standoffs (Fig. 5, pg. 6) by pressing down the mounting holes onto nylon standoffs. Make sure that boards are locked onto standoffs. 3. Fasten backplane to Trove2 enclosure utilizing lock nuts (provided). Fig. 5 EP1501, MR51e EP1501, MR51e EP1501, MR51e EP1501, MR51e EP1501, MR51e // Enclosure
7 TM2: Configuration of Boards (cont d) 1. Fasten standoffs (provided) to pems that match the hole pattern for MR50 (Fig. 6, pg. 7). Use male/female nylon standoffs only. 2. Affix boards to standoffs (Fig. 6, pg. 7) by pressing down the mounting holes onto nylon standoffs. Make sure that boards are locked onto standoffs. 3. Fasten backplane to Trove2 enclosure utilizing lock nuts (provided). Fig. 6 MR50 MR50 // Enclosure - 7 -
8 TV2: Configuration of Power Supply and/or Boards 1. Fasten standoffs (provided) to pems that match the hole pattern for Power Supply/Chargers or boards (Fig. 7, pg. 8). Use male/female nylon standoffs for the upper two mounting holes in the board. Use metal standoffs for the bottom mounting holes to provide sufficient grounding for the board. 2. Affix boards to standoffs (Fig. 7, pg. 8) by pressing down the upper mounting holes onto nylon standoffs. Use provided mounting screws to affix the lower mounting holes. Make sure that boards are locked onto standoffs. 3. Fasten backplane to Trove2 enclosure utilizing lock nuts (provided). Fig. 7 Power Supply or Metal Standoff Placement Power Supply or Metal Standoff Placement // Enclosure
9 TV2: Configuration of Boards 1. Fasten standoffs (provided) to pems that match the hole pattern for V1000 or V2000 boards (Fig. 8, pg. 9). 2. Mount boards to standoffs (Fig. 8, pg. 9) utilizing 7/8 pan head screws (provided). 3. Fasten backplane to Trove2 enclosure utilizing lock nuts (provided). Fig. 8 // Enclosure - 9 -
10 TMV2: Configuration of Boards 1. Fasten standoffs (provided) to pems that match the hole pattern for MR16IN or MR16OUT (Fig. 9, pg. 10). Use male/female nylon standoffs only. 2. Affix boards to standoffs (Fig. 9, pg. 10) by pressing down the mounting holes onto nylon standoffs. Make sure that boards are locked onto standoffs. 3. Fasten backplane to Trove2 enclosure door utilizing lock nuts (provided). Fig // Enclosure
11 TMV2: Configuration of Boards (cont d) 1. Fasten standoffs (provided) to pems that match the hole pattern for EP2500 or (Fig. 10, pg. 11). Use male/female nylon standoffs only. 2. Affix boards to standoffs (Fig. 10, pg. 11) by pressing down the mounting holes onto nylon standoffs. Make sure that boards are locked onto standoffs. 3. Fasten backplane to Trove2 enclosure door utilizing lock nuts (provided). Fig. 10 // Enclosure
12 TMV2: Configuration of Boards 1. Fasten standoffs (provided) to pems that match the hole pattern for V1000 or V2000 boards (Fig. 11, pg. 12). 2. Mount boards to standoffs (Fig. 11, pg. 12) utilizing 7/8 pan head screws (provided). 3. Fasten backplane to Trove2 enclosure door utilizing lock nuts (provided). Fig // Enclosure
13 TM2 and TV2 Mounting Diagram 7.5 (190.5mm) 19.4 (492.76mm) 7.5 (190.5mm) (633.73mm) ( 3.96mm) 25.4 (645.16mm) (412.62mm) (320.55mm) (320.55mm) (215.77mm) 1.0 (25.4mm) 0.45 (11.43mm) 7.5 (190.5mm) 1.0 (25.4mm) 7.5 (190.5mm) 9.2 (233.68mm) // Enclosure
14 TMV2 Mounting Diagram 18.1 (459.7mm) 13.7 (350mm) 7.4 (188mm) 23.7 (602mm) ( 3.96mm) 0.45 (11.43mm) (52.7mm) 8 (203.2mm) 8.7 (221mm) 8.7 (221mm) (274.8mm) 11.8 (299.7mm) 7.85 (199.39mm) 7.5 (190.5mm) 13.7 (350mm) // Enclosure
15 Notes: // Enclosure
16 Enclosure Dimensions (H x W x D approximate): x x 6.5 (692.15mm x mm x 165.1mm) 2.00 (50.8mm) 5.25 (133.35mm) 3.50 (88.9mm) (546.1mm) 3.50 (88.9mm) 5.25 (133.35mm) 1.25 (31.75mm) (14.29mm) (61.34mm) 1.77 (44.96mm) (17.399mm) Knockouts (28.32mm) (22.479mm) 6.25 (158.75mm) 6.25 (158.75mm) 1.25 (31.75mm) 0.85 (21.59mm) 1.5 (38.1mm) (502.92mm) 2.00 (50.8mm) 6.75 (171.45mm) G (685.8mm) 8.25 (209.54mm) 8.00 (203.2mm) 0.85 (21.59mm) 2.00 (50.8mm) 1.00 (25.4mm) 1.25 (31.75mm) 1.25 (31.75mm) 2.00 (50.8mm) 5.25 (133.35mm) 7.00 (177.79mm) 5.25 (133.35mm) 2.00 (50.8mm) is not responsible for any typographical errors. Product specifications are subject to change without notice th Street, Brooklyn New York USA, , fax: website: info@altronix.com. Made in USA. IITrove2M2/Trove2V2 - Rev F21P MEMBER // Enclosure
Installation Guide Versatile Access Power and Integration Enclosures
Rev. 053116 Installation Guide Versatile Access Power and Integration Enclosures Trove1C1 Trove2CV2 - Trove1 enclosure with - Trove2 enclosure with /CDVI backplane (TC1) /CDVI backplane (TCV2) TC1 TCV2
More informationAccess & Power Integration Solutions
ccess & Power Integration Solutions Installation Guide for models: T2MK3F4 - (1) eflow6n - Power Supply/Charger - (1) CM4 - Fused ccess Power Controller T2MK3F4Q - (1) eflow6n - Power Supply/Charger -
More informationExpandable Power Systems
Expandable Power Systems Installation Guide Models Include: Maximal11EV 12VDC @ 4A or 24VDC @ 3A. 12VDC @ 4A or 24VDC @ 3A. Maximal33EV 12VDC or 24VDC @ 6A. 12VDC or 24VDC @ 6A. Maximal37EV 24VDC @ 10A.
More informationDC Outdoor Power Supply/Chargers
DC Outdoor Power Supply/Chargers Installation Guide Models Include: WayPoint3 WayPoint7-2.5A @ 12VDC or 24VDC. - 6A @ 12VDC or 24VDC. - 115/230VAC input. - 115VAC input. WayPoint5 WayPoint7V - 4A @ 12VDC
More information718.567.8181 info@altronix.com 1 Trove access and power integration solutions easily combine Altronix power and accessories with access controllers available from the industry s leading manufacturers.
More informationAL168 Series Multi-Output Power Supplies
AL168 Series Multi- Power Supplies Installation Guide Models Include: AL168CB - 16VAC @ 6A (100VA) or 18VAC @ 5.5A (100VA). AL168175CB - 16VAC @ 10A (175VA). AL168300CB - 16VAC @ 18A (350VA) or 18VAC @
More information3-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide
Embedded 3-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide Models include: NetWaySP3WP - Includes Fiber Optic SFP 1G, 3-port PoE+ switch and power supply. - NEMA4/4X, IP66 rated Outdoor
More information4-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide
Embedded 4-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide Models include: NetWaySP4WP - Includes Fiber Optic SFP 1G Link, 4-port PoE+ switch and power supply. - NEMA4/4X, IP66 rated
More informationActive UTP Transceiver Hub with Integral Isolated Camera Power
Active UTP Transceiver Hub with Integral Isolated Installation Guide HubWayEX16SP - UL Listed sixteen (16) Channel Active UTP Transceiver Hub with Integral Isolated Rev. 011810 More than just power. TM
More information8-Port Ethernet over Fiber PoE Hardened Switches Installation Manual
Embedded 8-Port Ethernet over Fiber PoE Hardened Switches Installation Manual NetWaySP8WP - Includes Fiber Optic SFP 1G Link, 8-port PoE switch and power supply. - NEMA4/4X, IP66 rated Outdoor enclosure.
More informationRack Mount Power Supplies
Rack Mount Power Supplies Installation Guide Models Include: VertiLine33D - 12VDC @ 8A - Sixteen (16) PTC protected outputs VertiLine33TD - 12VDC @ 16A - Sixteen (16) PTC protected outputs VertiLine63D
More informationlong range ethernet Extend Ethernet range 5x the distance - without repeaters. Long Range Ethernet Adapters Features:
FEATURED PRODUCTS SECURITY / ACCESS / FIRE / SURVEILLANCE long range ethernet 2 Extend Ethernet range 5x the distance - without repeaters. - Deploy IP cameras/edge devices up to 500m over CAT5e/6. - Passes
More informationPassive UTP Transceiver Hub with Integral Camera Power Installation Guide
Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubWay8D HubWay16D - Eight (8) Channels - Sixteen (16) Channels HubWay82D HubWay162D - HubWay8 w/eight (8) HubWayAv - HubWay16
More informationTransceiver Hub with Integral Camera Power
Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubWay8CD HubWay16CD - UL Listed eight (8) Channel Passive UTP - UL Listed sixteen (16) Channel Passive UTP Transceiver Hub
More informationActive UTP Transceiver Hub with Integral Camera Power Installation Guide
Active UTP Transceiver Hub with Integral Installation Guide Models Include: HubWayLD8CDS - UL Listed eight (8) Channel Active UTP Transceiver Hub with Integral HubWayLD82CDS - UL Listed eight (8) Channel
More informationPassive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide
Passive UTP Transceiver Hub with Integral Isolated Installation Guide Models Include: HubWay8Di HubWay16Di - UL Listed eight (8) Channel Passive UTP - UL Listed sixteen (16) Channel Passive UTP Transceiver
More informationActive UTP Transceiver Hub with Integral Camera Power Installation Guide
Active UTP Transceiver Hub with Integral Installation Guide Models Include: HubWayLD8D HubWayLD16D - Eight (8) Channels - Sixteen (16) Channels HubWayLD82D HubWayLD162D - HubWayLD8D w/eight (8) HubWayAv
More informationActive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide
Active UTP Transceiver Hub with Integral Isolated Installation Guide Models Include: HubWayLD8Di HubWayLD16Di - UL Listed eight (8) Channel Active UTP - UL Listed sixteen (16) Channel Active UTP Transceiver
More informationEnclosures AE1/AE3. Installation Guide
Enclosures AE1/AE3 en Installation Guide Enclosures Safety en 3 1 Safety Notice! Do not flush mount! Regulatory agency requirements prohibit flush mounting the enclosures.! Caution! Ensure the enclosure
More informationNew IP & Power Solutions. for 2018
New IP & Power Solutions for 2018 long range ethernet 2 Extend Ethernet range 5x the distance - without repeaters. - Deploy IP cameras/edge devices up to 500m over CAT5e/6. - Passes PoE/PoE+ generated
More informationNetWay1DWP - Outdoor Single Port Hi-PoE Injector NetWay1DWPM - Outdoor Managed Single Hi-PoE Injector I.T.E. 43KC
Installation Guide NetWay1DWP - Outdoor Single Port Hi-PoE Injector NetWay1DWPM - Outdoor Managed Single Hi-PoE Injector I.T.E. 43KC Rev. 112713 Overview: Altroni NetWay1DWP Outdoor Single Port Midspan
More informationUser s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1)
User s Guide Includes Mounting, Installation, and Product Registration 500 19009 62nd Avenue NE Arlington, WA USA (+1) 360-435-6030 European Sales Office Barcelona, España (+34) 600-843-845 www.outbackpower.com
More informationInstructions to Install Retrofit Kit RVMC 4/5000 Machine (MDB Only)
Instructions to Install Retrofit Kit RVMC 4/5000 Machine (MDB Only) **TURN POWER OFF OF MACHINE BEFORE INSTALLATION** READ ALL INSTRUCTIONS BEFORE STARTING INSTALLATION Retrofit Kit Contents PART NAME
More information13 MMC for PC Option Modules
Part Number M.1300.8684 MMC for PC Option Modules Manual V3.0 The information in this document is also available in the MMC for PC Hardware Manual. 13 MMC for PC Option Modules 13.1 General The MMC for
More informationUniversal Desktop and Monitor Stand
Universal Desktop and Monitor Stand Installation Instructions Kit P/N: 114-6013 Kit Contents Kit Contents: (1) Stand Assembly (1) VESA Monitor Bracket (1) Bottom Bracket (1) Top Bracket (1) Clamp Bracket
More informationMiR Top camera. Intel RealSense TM Camera (R200) Technical Documentation
MiR Top camera Intel RealSense TM Camera (R200) Technical Documentation Version 1.1 Release date: 21.12.2016 Table of contents 1 Introduction...3 2 What s included in the box?...3 3 Mounting the top camera...4
More informationInstallation Guide. Rev
Installation Guide Rev. 120913 NetWay4ES - 4-Port Managed /+ Switch NetWay4ESK - Kit includes: NetWay4ES and NetWay1E (84W Midspan Injector, 115VAC input) NetWay4ESKV - Kit includes: NetWay4ES and NetWay1EV
More informationSynergis Cloud Link Hardware Installation Guide 3.0. Click here for the most recent version of this document.
Synergis Cloud Link Hardware Installation Guide 3.0 Click here for the most recent version of this document. Document last updated: February 15, 2018 Copyright notice Genetec Inc., 2018 Genetec Inc. distributes
More informationPoE Managed Midspan Solution for Standard Network Infrastructure
Power over the Ethernet PoE Managed Midspan Solution for Standard Network Infrastructure Installation Guide Models Include: NetWay8M NetWay16M - Eight (8) Port PoE Midspan Injector - Sixteen (16) Port
More informationPassive UTP Transceiver Hub Installation Guide
Video Data Passive UTP Transceiver Hub Installation Guide Models Include: - Sixteen (16) Camera Channels Rev. 121710 More than just power. TM Overview: Altronix Passive UTP Transceiver Hub transmits UTP
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS 19 20 21 01 07 22 23 13 10 12 08 17 18 11 02 14 15 04 03 16 WELCOME PARTS LIST Thank you for purchasing this HealthPoint Technology Cabinet from Humanscale! Before you begin installing
More informationHomeWorks Remote Power Feed-Through Panels
power feed-through panels are available in two different sizes, each of which may be either surface-mounted or recess-mounted, in an electrical closet or other equipment room. The number of remote power
More informationTruPortal Dual Door Interface Module Quick Reference
TruPortal Dual Door Interface Module Quick Reference en-us Packing List Introduction The TruPortal Dual Door Interface Module (TP-ADD-2D) can support two complete door configurations, with up to two readers
More informationHow to Design Custom Enclosures for Motherboard-Based Systems
PROTOCASE TECHNICAL BULLETIN How to Design Custom Enclosures for Motherboard-Based Systems (covering ATX and Mini ITX form factors) Document Edition - 1 Last Updated: June 6 th,2011 Protocase, Inc. All
More informationFLEXBOX. Installation Guide
FLEXBOX Installation Guide FLEXBOX 1 Important Safety Instructions WEIGHT LIMIT MAXIMUM WEIGHT 50 LBS. THE STRUCTURE TO WHICH THE BOX IS MOUNTED (CEIL- ING, WALL, TABLE, POLE) MUST BE ABLE TO SUPPORT FIVE
More informationHAW-SIBU. Rack Installation Guide. Version 1.0.1
HAW-SIBU Rack Installation Guide Version 1.0.1 Mounting HAW-SIBU in a Rack The instructions here apply to the Sony HAW-SIBU. Cautions * Do not lift or move the HAW-SIBU unit by the handles on the ear brackets
More informationNetwork Power Distribution Module
Please be sure to visit altronix.com for latest firmware and installation instructions Network Power Distribution Module Installation and Programming Manual Models include: LINQ8PD - Network Power Distribution
More informationATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES
1. Turn off and unplug the game. COPYRIGHT 2007 MERIT ENTERTAINMENT 2. Unlock and open the CPU section. Ion evo/evo Wallette/Elite Edge ECS Motherboard Removal 3. Remove the 3 screws securing the I/O board
More informationINSTRUCTIONS FOR THE INSTALLATION OF THE INFINITY "L" DISPLAY HOOD (INTO PREVIOUSLY INSTALLED INFINITY "L" SYSTEMS)
Doc. 6001025 Rev B INSTRUCTIONS FOR THE INSTALLATION OF THE INFINITY "L" DISPLAY HOOD (INTO PREVIOUSLY INSTALLED INFINITY "L" SYSTEMS) Rev. B Doc. 6001025 Page 1 of 13 IMPORTANT NOTICE This document covers
More informationebridge200b - Managed Two Port Transceiver Board
PLUS ebridge200b - Managed Two Pt Transceiver Board Installation Guide Rev. 049207 Overview: ebridge200b long range Ethernet transceiver/media converter transmits data and power over Coax CAT5 cable over
More informationINSTRUCTION BULLETIN
INSTRUCTION BULLETIN No. 9008755 Machine: T16 Published: 03-2011 Rev. 00 NOTE: DO NOT DISCARD the Parts List from the Instruction Bulletin. Place the Parts List in the appropriate place in the machine
More informationSeries Amp Pad Mount Quick Connect Input and Output Power Panels
Series 300 2000-4000 Amp Pad Mount Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury.
More informationConnecting a Cisco Input Module
CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each
More informationINSTALLATION INSTRUCTIONS
TM REPLACEMENT PARTS FOR USE WITH CX SERIES PANELS INSTALLATION INSTRUCTIONS Hubbell Control Solutions 9601 Dessau Road Building One Suite 100 Austin, TX 78754 Toll Free: 888-698-3242 Fax: 512-450-1215
More informationE1135C PDU and Pod Upgrade Procedure
E4030-90010 Rev. B 12/2003 In this Document... Tools Needed, 2 Contents of the Upgrade Kits, 2 Installation Procedures, 4 Verifying the Power Option of the New PDU, 4 Removing the PDU from the Support
More informationTerminal Equipment Controller Enclosure
Document No. 550-196 Terminal Equipment Controller Enclosure Product Description A Terminal Equipment Controller enclosure is a general-purpose metal cabinet with a removable cover that houses an electronic
More informationUse flat head screws for the out side of chassis and pan head screw for inside of chassis.
These are instructions are guidelines in building a Storage Pod. 2-a Use flat head screws for the out side of chassis and pan head screw for inside of chassis. 1. Take the main chassis and check the chassis
More informationSeries Amp Quick Connect Input and Output Power Panels
Series 300 1200-1600 Amp Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury. WARNING is
More informationSVP48 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL
SVP48 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL REVISION: 3/03 COPYRIGHT (c) 1995-2003 CAMPBELL SCIENTIFIC, INC. This is a blank page. Warranty and Assistance The SVP48 SURGE VOLTAGE PROTECTOR is warranted
More informationPCLASS Integrated Paxton Access Power
PCLASS Integrated Paxton Access Power All-in-one multi-door power solutions for Paxton Net2 and BLU controllers. Single and Dual Voltage, Standard and Networked. PCLASS Product Guide {jatabs type="content"
More informationKit K Instructions. V8700 to Alpha Conversion Instructions
V8700 to Alpha Conversion Instructions Contents Contents Installation Instructions for Kit K-00927-0001 Before You Begin..................................................................................
More informationModels 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions
299-600-96 Rev. F MCG Surge Protection Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions Important Warranty Information: MCG surge protectors are designed to work at specific voltages
More informationBL-FLOWSTN-P FlowStation Module Installation Guide
Introduction Baseline s FlowStation is available as an add-on module that is installed inside a pedestal enclosure with a BaseStation 3200 irrigation controller. The FlowStation module comes with a 5-port
More informationEWS660AP. Quick Installation Guide
Package contents - Managed indoor access point - Power adapter - RJ-45 Ethernet cable - Mounting bracket - Mounting kit - T-Rail mounting kit IP Adress configuration Step 1: Once your computer is on, ensure
More informationInstallation and User Guide
Installation and User Guide VADDIO DOMEVIEW HD INDOOR PENDANT MOUNT DOME ENCLOSURE FOR THE VADDIO HD-20, HD-19 AND HD-18 PTZ CAMERAS Part Number: 998-9100-200 2011 Vaddio - All Rights Reserved DomeVIEW
More informationENTRACOMP 26SA With Remote Open Input. User/Installation Manual
ENTRACOMP 26SA With Remote Open Input User/Installation Manual COPYRIGHT 2001 SOUNDCRAFT INC. PRINTED IN U.S.A. TABLE OF CONTENTS INTRODUCTION... 1 SETTING THE SYSTEM (FACILITY) CODE... 3 PROGRAMMING THE
More informationPACSystems* RX3i IC695ACC650
September 2012 PACSystems* RX3i IC695ACC650 Series 90-70 to RX3i Conversion Rack The conversion rack provides a solution for converting an existing Series 90-70 system to PACSystems RX3i, minimizing outage
More informationIS-DM220/IR/HB IS-DM220
IS-DM220/IR/HB IS-DM220 Installation Guide Indoor/Outdoor Ver. 1.2 00P6NX223ZXSEA2 Table of Contents 1. Indoor Camera Installation... 3 1.1 Hard Ceiling... 3 1.2 In-Ceiling (T-Bar) Mounting... 13 1.3 4S
More informationSITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions
Introduction 1 Installing/Mounting 2 SITRANS F Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel Hardware Installation Instructions 1/2010 A5E02518333A Revision 04 Legal information Warning notice
More informationDigital Si g n a g e Co l l e c t i o n
Digital Si g n a g e Co l l e c t i o n A u d i o / V i s u a l M o u n t i n g S o l u t i o n s f o r D I G I T A L S I G N A G E WALL MOUNTS. Quick Installation Screen specific spacers reduce multi-screen
More informationTykoflex Splice System
for 9 /ETSI optical fibre racks T YKOFLEX SPLICE SYSTEM Tykoflex Splice System About Tykoflex With telecom and fibre optics technology now being used for a large number of applications such as telephony,
More informationModel CPS2 - CPS1000. Power Supply / Battery Charger. Operating and Installation Instructions Rev B.02 CPS200/400 ALARMSAF CPS 800/1000 J4 J3
AC J1 AC DC1 DC2 J2 J2 J3 S1 VOLTS 6 12 24 J1 C O O J2 C C O CS200/400 J4 J3 ALARMSAF J1 CS 800/1000 Model CS2 - CS1000 ower Supply / Battery Charger Operating and Installation Instructions I. Warnings
More informationPowerLogic High Density Metering System 1-Meter Enclosure
PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these
More informationINSTALLATION INSTRUCTIONS YAMAHA Speaker Adapter Accessory Model: PAC-Y2
INSTALLATION INSTRUCTIONS YAMAHA Speaker Adapter Accessory BEFORE YOU BEGIN CAUTION! The instructions provided in this document outline the installation of the PAC-Y2 Lateral Shift Accessory to specific
More information7" Touch Screen Display
7" Touch Screen Display Installation Guide Contents Minimum Requirements...1 Select a Location...1 Initial Setup...2 Unboxing...2 Installation...3 Prepare the Panel...3 Install the Mounting Plate...3 Mount
More informationAM-516. Adaptor Ring. User s Manual. Complies with FD8162 fixed dome camera. Rev IP Surveillance
AM-516 Adaptor Ring User s Manual Complies with FD8162 fixed dome camera Rev. 1.0 IP Surveillance I Overview AM-516 Adaptor Ring Adaptor ring for FD8162 fixed dome camera. The supported installation types
More informationmodular enclosure MUREVA, IP65 weatherproof & versatile enclosures aesthetics multi-functional evolutionary ergonomics and time saving security
aesthetics c Elegant and robust design. c Colour easy to integrate in any environment. weatherproof & versatile enclosures multi-functional c Different solutions for: industrial control, electrical distribution,
More informationInstalling the DX LCD Display
DX LCD Display User s Guide 3-1 Chapter 3 Installing the DX LCD Display Introduction Use the DX LCD Display as either a portable device, or permanently mount it in a panel or on the wall. For panel and
More informationAssembly and Setup Manual
M-11 Series Copyboard/C-11 Series Captureboard Assembly and Setup Manual This is the installation and assembly manual for the M-11 series/c-11 series. To the Customer Specialized techniques are required
More informationInstalling a Power over Ethernet injector
Installing a Power over Ethernet injector AlphaEclipse StreetSmart and RoadStar signs The instructions in this document explain how to install/replace a Power over Ethernet (PoE) injector in a StreetSmart
More informationCOMPLETE S YSTEM SHELTER
COMPLETE S YSTEM SHELTER The weather-resistant Complete System Shelter (CSS) provides protection from the elements for system components such as the console, Solar Power Kit components, sensor interface
More informationFlat Panel Static Wall Mount MSP-SS (GSM-210)
INSTALLATION INSTRUCTIONS Flat Panel Static Wall Mount (GSM-2) The static wall mount fits most 23 to 30 displays. The mount was designed to adapt to the VESA 75mm/0mm, 0mm/0mm, and 200mm/0mm compliant
More informationMicroTech II TM Remote I/O Panel Installation Manual
Installation Manual IM 783-0 MicroTech II TM Remote I/O Panel Installation Manual Group: Controls Part Number: IM 783-0 Date: February 2004 Supersedes: New 2004 McQuay International Page 2 IM-783 Table
More informationFortiCam FD40 Mounting Guide
FortiCam FD40 Mounting Guide 1 FORTINET DOCUMENT LIBRARY http://docs.fortinet.com FORTINET VIDEO GUIDE http://video.fortinet.com FORTINET BLOG https://blog.fortinet.com CUSTOMER SERVICE & SUPPORT https://support.fortinet.com
More informationEthernet/Network Communications Module. Installation and Programming Manual. LINQ2 - Two (2) Port Connectivity Module. More than just power.
Ethernet/Network Communications Module Installation and Programming Manual LINQ2 - Two (2) Port Connectivity Module DOC#: LINQ2 Rev. 060514 More than just power. Overview: Altronix LINQ2 network module
More informationTitan Media Cart. Installation and Operation Manual
Titan Media Cart Installation and Operation Manual Table of Contents INTRODUCTION SERVICE AND SUPPORT... 1 PRODUCT RETURNS... 1 UNPACKING... 1 TITAN SINGLE MEDIA CART... 2 TITAN DUAL MEDIA CART... 2 BEFORE
More informationTruPortal Output Expansion Board Quick Reference
TruPortal Output Expansion Board Quick Reference en-us Packing List Introduction A TruPortal system can be expanded by adding an Input/Output Expansion module (TP-ADD-IO-BRD) that consists of: One TruPortal
More informationPhase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:
Phase Loss Protection Upgrade In this bulletin: Introduction... 2 Purpose... 2 General... 2 Applicability... 2 HD3070 Phase Loss Protection Upgrade Kit Parts... 2 Preparation... 4 Install the Phase Loss
More informationTDM To MiniMech conversion ProceDure
TDM To MiniMech conversion ProceDure (Model 9100 ATM) TDN 07102-00079 Apr 1 2009 CorporATe HeAdquArTers: 522 E. Railroad Street Long Beach, MS 39560 PHONE: (228) 868-1317 FAX: (228) 868-0437 COPYRIGHT
More informationCisco Aironet Hard Ceiling Mounting Adapter (AIR-ANTMNTGKIT)
Cisco Aironet Hard Ceiling Mounting Adapter (AIR-ANTMNTGKIT) Introduction The can be used to mount the Cisco Aironet antennas to hard ceilings. The following antennas, as well as others, may be used with
More informationProbably the fastest enclosure in the world
95 9 enclosure system Probably the fastest enclosure in the world Sample configuration tools required no no tools required Vitaro can be assembled within less than 60 seconds. 00:00 00:0 00:08 00: 00:5
More informationRoyal RVV-500 (B) Retrofit Kit
Optipay BV/RC/CC into a Non-Fascia Vending Machine This document contains information for installing and configuring the JCM Optipay DBV-01 Bill Validator, RC-10 Bill Recycler and A-66 Coin Changer into
More informationTELEPHONE FLUSH WALL PLATE
TELEPHONE FLUSH WALL PLATE Single Jack Modular flush wall jack assembly allows flush-mounted connection of plug-ended modular line cords. Ideal for initial installation or conversion from existing wall
More informationReplacing the Colored Accent Ring EXTREME-PERFORMANCE 240MM LIQUID CPU COOLER QUICK START GUIDE
TM / Replacing the Colored Accent Ring To replace the colored accent ring, use a small flathead screwdriver to pry out the default metallic grey ring at three corners, located as shown in figure 1. Then
More informationAssembly Instructions for #5630 Medication PalWOW
Assembly Instructions for #5630 Medication PalWOW Before assembling, please familiarize yourself with all the parts and check to make sure you have all the parts as listed below. A B A & B - The box in
More informationUSBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version
USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version 2015 Calmotion LLC, All rights reserved Calmotion LLC 21720 Marilla Street Chatsworth, CA 91311
More information15P0097Q1 SINUS K - PENTA REMOTE MOUNTING THE KEYPAD MOUNTING GUIDE
15P0097Q1 THE KEYPAD MOUNTING Upd. 12/01/06 R. 01 English This manual is integrant and essential to the product. Carefully read the instructions contained herein as they provide important hints for use
More informationDigital Menu Board Wall Mount Installation Instructions
Digital Menu Board Wall Mount Installation MDSWMB2T4249 MDSWMB3T4249 www.microndisplaysolutions.com Table of Contents Important Safety... 3 Models and Specifications... 4 Package Contents... 5 Step 1 Two(2)
More informationEP/2 Installation Instructions
1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in
More informationicp installation guide
The Information Control Point (icp) is the latest SmartFarm Technology by Inc. The icp is the ultimate on-farm data-management tool. The icp has all the power of a basic personal computer, but instead
More informationHD WiFi Indoor / Outdoor Camera Guide
HD WiFi Indoor / Outdoor Camera Guide Connectwith Beam VER-Z2C 1 Mobile Setup Before you perform any permanent installation, make sure you complete the mobile setup to configure your camera or camera kit.
More informationVertiv VR Rack 1.0 GENERAL
1.1 SUMMARY Vertiv VR Rack Guide Specifications 1.0 GENERAL This specification defines the mechanical characteristics and requirements for the Vertiv VR Rack. A series of adaptive and scalable electronic
More informationWireless Key fob, Key pad & Receiver Range
Wireless Key fob, Key pad & Receiver Range 4Ch Wireless Receiver 4x Voltage Free relay outputs (NO + NC) 100m Transmission range Multiple user codes 2 Channel wireless control Clear hinge up lid 12V DC
More informationPXC Compact Unitary Equipment Controller (UEC)
Document No. 553-169 PXC Compact Unitary Equipment Controller (UEC) Product Description The PXC Unitary Equipment Controller (UEC) is an MS/TP device that can be configured as a programmable, stand-alone
More informationInstalling Cisco RP-Series PDUs
This chapter contains the following sections: Preparing to Install an RP-Series PDU, page 1 Installing a Zero-U PDU, page 1 Installing a 1RU or 2RU PDU, page 7 Preparing to Install an RP-Series PDU Before
More informationMicrosoft Azure StorSimple Appliance 8600 Hardware Installation Guide
Microsoft Azure StorSimple Appliance 8600 Hardware Installation Guide Contents Unpack your device... Prerequisites... Unpacking your device... Rack-mount your device... Site preparation... Prerequisites...
More information3630P Encl 34X28 Enclosure Panel. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 3630P Encl 34X28 Enclosure Panel Cooper B-Line/Cable Tray Manufacturer Weight per unit Product Category Features Material
More informationConnecting a Cisco Output Module
CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which
More informationInstallation manual CF8-W-Disp-AL
Installation manual CF8-W-Disp-AL CO 2 transmitter with two relays mounted in industrial housing prepared for Modbus communication protocol 4 7 8 8 6 3 2 5 Wall plate 5 Snap-in lid 2 PCB (Factory supplied
More informationField Installation Manual External Bolt-On Economizer for ComPac I Air Conditioners
Field Installation Manual External Bolt-On Economizer for ComPac I Air Conditioners Models: ComPac AVPA 42-48-60 The following instructions describe how to install the Marvair External Bolt-On Field Installed
More information