INSTRUCTION MANUAL. Switch/Proximity Detector Repeater Relay Output DIN-Rail Models D1030S, D1030D D1030S - D1030D

Size: px
Start display at page:

Download "INSTRUCTION MANUAL. Switch/Proximity Detector Repeater Relay Output DIN-Rail Models D1030S, D1030D D1030S - D1030D"

Transcription

1 D00S D00D INSTRUCTI MANUAL Switch/Proximity Detector Repeater Relay DINRail Models D00S, D00D D00 Switch / Proximity Detector Repeater Relay ISM0000

2 Characteristics General Description: The Switch/Proximity Detector Repeater type D00 is a DIN Rail unit with one or two independent channels. The unit can be configured for contact or proximity detector, or NC and for or SPDT relay output contact. Each channel enables a Safe Area load to be controlled by a switch, or a proximity detector, located in Hazardous Area. D00D dual channel type has two independent input channels and actuates the corresponding output relay. Two actuation modes can be independently DIP switch configured on each input channel: input/ relay or input/ relay. Contact or proximity sensor and its connection line short or open circuit fault detection is also DIP switch configurable: fault detection can be enabled (in case of fault it deenergizes the corresponding output relay and turns the fault LED on) or disabled (in case of fault the corresponding output relay repeats the input line open or closed status as configured). D00S single channel type has one input channel and two output relays; the unit has two DIP switch configurable operating modes: Mode A) input channel actuates in parallel the two output relays (DPDT contact). Relay actuation mode can be independently configured for each output in two modes: input/ relay or input/ relay. Mode B) input channel actuates output relay A configurable in two modes as in mode A above. relay B operates as a fault output (in case of input fault, relay B actuates and the fault LED turns on while relay A repeats the input line as configured). Actuation can be DIP switch configured in two modes: No input fault/energized relay (it deenergizes in case of fault) or No input fault/deenergized relay (it energizes in case of fault). Function: or channels I.S. switch repeater for contact or EN09 proximity. Provides port isolation (input/output/supply). Signalling LEDs: Power supply indication (green), output status (yellow), line fault (red). Field Configurability: /NC input for contact/proximitor, / relay operation and fault detection enable/disable. EMC: Fully compliant with CE marking applicable requirements. Technical Data Supply: Vdc nom (0 to 0 Vdc) reverse polarity protected, ripple within voltage limits Vpp. Current V: 0 ma for channels D00D, ma for channel D00S with input closed and relays energized. Power dissipation:. W for channels D00D,. W for channel D00S with V supply voltage, input closed and relays energized. Max. power consumption: at 0 V supply voltage, short circuit input and relays energized,. W for channels D00D,. W for channel D00S. Isolation (Test Voltage): I.S. In/Out. KV; I.S. In/Supply. KV; Out/Supply. KV; Out/Out. KV. switching current levels:. ma,. ma, switch current. ma ± 0. ma hysteresis. Fault current levels: open fault 0. ma, short fault. ma (when enabled both faults deenergize channel relay with dual channel unit D00D or actuate fault relay with single channel unit D00S). equivalent source: V KΩ typical ( V no load, ma short circuit). : voltage free SPDT relay contact. Contact material: AgCdO. Contact rating: A 0 Vac 00 VA, A 0 Vdc 0 W (resistive load). DC Load breaking capacity: V (V) Resistive Load I (A) Mechanical / Electrical life: 0 * 0 / * 0 operation, typical. Operate / Release time: / ms typical. Bounce time / NC contact: / ms. Response time: 0 ms. Frequency response: 0 Hz maximum. Compatibility: CE mark compliant, conforms to 9/9/EC Atex Directive and to 00/0/CE EMC Directive. Environmental conditions: Operating: temperature limits 0 to 0 C, relative humidity max 90 % non condensing, up to C. Storage: temperature limits to 0 C. Safety Description: II () G [Ex ia Ga] IIC, II () D [Ex ia Da] IIIC, I (M) [Ex ia Ma] I, II G Ex na IIC T, [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I associated electrical apparatus. Uo/Voc 0. V, Io/Isc ma, Po/Po 9 mw at terminals,. Um 0 Vrms, 0 C Ta 0 C. Approvals: DMT 0 ATEX E 0 X conforms to EN0090, EN009, EN009, EN0, EN, IECEx BVS 0.00X conforms to IEC0090, IEC009, IEC009, IEC0, IEC, GM International CRR0 conforms to EN0090, EN009, UL & CUL E0 conforms to UL9 (Div.),UL 0090 (General, All Zones), UL009 (Intrinsic Safety i Zones 0 & ) for UL and CSAC. No.9 (Div.), CSAE0090 (General, All Zones), CSAE009 (Intrinsic Safety i Zones 0 & ) for CUL, refer to control drawing ISM0 for complete UL and CUL safety and installation instructions, FM & FMC No. 0, 099C, conforms to Class 00, 0,, 0 and C. No., C. No., C. No., E0090, E009, E009, Russia according to GOST..00.0, R 0.099, R [Exia] IIC X, Ukraine according to GOST..00.0,.0,. Exia IIC X, DNV and KR Type Approval Certificate for marine applications. Mounting: T DIN Rail according to EN00. Weight: about g D00D, 0 g D00S. Connection: by polarized plugin disconnect screw terminal blocks to accomodate terminations up to. mm. Location: Safe Area/Non Hazardous Locations or Zone, Group IIC T, Class I, Division, Groups A, B, C, D Temperature Code T and Class I, Zone, Group IIC, IIB, IIA T installation. Protection class: IP 0. Dimensions: Width. mm, Depth 99 mm, Height. mm. D00 Switch / Proximity Detector Repeater Relay G.M. International ISM0000

3 Ordering information Model: D00 channel S channels D Power Bus enclosure Front Panel and Features /B from Zone 0 (Zone 0), Division, installation in Zone, Division. /NC contact/proximity Detector. Two SPDT Relay Signals. SPDT Relay for fault detection on single channel version. Three port isolation, //Supply. EMC Compatibility to EN000, EN000. PWR STATUS/ FAULT D00 Infield programmability by DIP Switch. ATEX, IECEx, UL & CUL, FM & FMC, Russian and Ukrainian Certifications. Type Approval Certificate DNV and KR for marine applications. High Reliability, SMD components. High Density, two channels per unit. Simplified installation using standard DIN Rail and plugin terminal blocks. 0 Vrms (Um) max. voltage allowed to the instruments associated with the barrier. G.M. International ISM0000 D00 Switch / Proximity Detector Repeater Relay

4 Terminal block connections HAZARDOUS AREA D00D SAFE AREA Ch for Proximity or Ch for Voltage free Contact Ch Common Ch for Proximity or Ch for Voltage free Contact Ch Relay Normally Opened () Ch for Proximity or Ch for Voltage free Contact Power Supply Vdc Ch for Proximity or Ch for Voltage free Contact Power Supply Vdc Ch Common Ch Relay Normally Opened () Ch Relay Normally Closed (NC) Ch Relay Normally Closed (NC) HAZARDOUS AREA D00S SAFE AREA Ch for Proximity or Ch for Voltage free Contact Ch A Common Ch for Proximity or Ch for Voltage free Contact Ch A Relay Normally Opened () Power Supply Vdc Power Supply Vdc Ch B Common Ch B Relay Normally Opened () Ch B Relay Normally Closed (NC) Ch A Relay Normally Closed (NC) D00 Switch / Proximity Detector Repeater Relay G.M. International ISM0000

5 Parameters Table In the system safety analysis, always check the Hazardous Area/Hazardous Locations devices to conform with the related system documentation, if the device is Intrinsically Safe check its suitability for the Hazardous Area/Hazardous Locations and gas group encountered and that its maximum allowable voltage, current, power (Ui/Vmax, Ii/Imax, Pi/Pi) are not exceeded by the safety parameters (Uo/Voc, Io/Isc, Po/Po) of the D00 series Associated Apparatus connected to it. Also consider the maximum operating temperature of the field device, check that added connecting cable and field device capacitance and inductance do not exceed the limits (Co/Ca, Lo/La, Lo/Ro) given in the Associated Apparatus parameters for the effective gas group. See parameters on enclosure side and the ones indicated in the table below: D00 Terminals D00 Associated Apparatus Parameters Must be Hazardous Area/ Hazardous Locations Device Parameters Ch Ch Uo / Voc 0. V Ui / Vmax Ch Ch Io / Isc ma Ii/ Imax Ch Ch Po / Po 9 mw Pi / Pi D00 Terminals D00 Associated Apparatus Parameters Must be Hazardous Area/ Hazardous Locations Device Cable Parameters Ch Ch Co / Ca. µf Co / Ca. µf Co / Ca 9 µf (IICA, B) (IIBC) (IIAD) Ci / Ci device C cable Ch Ch Lo / La mh Lo / La 9 mh Lo / La 9 mh (IICA, B) (IIBC) (IIAD) Li / Li device L cable Ch Ch Lo / Ro 90 µh/ω Lo / Ro 0 µh/ω Lo / Ro 0 µh/ω (IICA, B) (IIBC) (IIAD) Li / Ri device and L cable / R cable TE for USA and Canada: IIC equal to Gas Groups A, B, C, D, E, F and G IIB equal to Gas Groups C, D, E, F and G IIA equal to Gas Groups D, E, F and G For installations in which both the Ci and Li of the Intrinsically Safe apparatus exceed % of the Co and Lo parameters of the Associated Apparatus (excluding the cable), then 0 % of Co and Lo parameters are applicable and shall not be exceeded (0 % of the Co and Lo become the limits which must include the cable such that Ci device C cable 0 % of Co and Li device L cable 0 % of Lo). If the cable parameters are unknown, the following value may be used: Capacitance 0pF per foot (0pF per meter), Inductance 0.0µH per foot (0.0µH per meter). The Intrinsic Safety Entity Concept allows the interconnection of Intrinsically Safe devices approved with entity parameters not specifically examined in combination as a system when the above conditions are respected. For Division and Zone 0 installations, the configuration of Intrinsically Safe must be FM approved under Entity Concept (or third party approved); for Division installations, the configuration of Intrinsically Safe must be FM approved under nonincendive field wiring or Entity Concept (or third party approved). G.M. International ISM0000 D00 Switch / Proximity Detector Repeater Relay

6 Function Diagram HAZARDOUS AREA ZE 0 (ZE 0) GROUP IIC, HAZARDOUS LOCATIS CLASS I, DIVISI, GROUPS A, B, C, D, CLASS II, DIVISI, GROUPS E, F, G, CLASS III, DIVISI, CLASS I, ZE 0, GROUP IIC SAFE AREA, ZE GROUP IIC T, N HAZARDOUS LOCATIS, CLASS I, DIVISI, GROUPS A, B, C, D TCode T, CLASS I, ZE, GROUP IIC T MODEL D00D Common positive connection Supply Vdc voltage free Contact Proximity NC In Out COM voltage free Contact Proximity NC In Out COM MODEL D00S In voltage free Contact Proximity Supply Vdc NC Out A COM NC COM Out B Relay contact shown in deenergized position D00 Switch / Proximity Detector Repeater Relay G.M. International ISM0000

7 Warning D00 series are isolated Intrinsically Safe Associated Apparatus installed into standard EN00 T DIN Rail located in Safe Area/Non Hazardous Locations or Zone, Group IIC, Temperature Classification T, Class I, Division, Groups A, B, C, D, Temperature Code T and Class I, Zone, Group IIC, IIB, IIA Temperature Code T Hazardous Area/Hazardous Locations (according to EN/IEC009, FM Class No., CSAC. No. M9, CSAE009) within the specified operating temperature limits Tamb 0 to 0 C, and connected to equipment with a maximum limit for AC power supply Um of 0 Vrms. Hazardous (Classified) Locations Class I, Division, Groups A, B, C, D Class II, Division, Groups E, F, G Class III, Division Class I, Zone 0, Group IIC, IIB, IIA Intrinsically Safe Intrinsically Safe Unclassified Locations or Hazardous (Classified) Locations Class I, Division, Groups A, B, C, D, TCode T Class I, Zone, Group IIC, IIB, IIA, TCode T D00 Associated Apparatus FM Approved under Entity Concept and nonincendive field wiring Unclassified Locations Must not use or generate more than 0 Vrms or Vdc Control Control FM Approved under Entity Concept, or third party approval Power Supply Hazardous (Classified) Locations Class I, Division, Groups A, B, C, D Class II, Division, Groups E, F, G Class III, Division Class I, Zone, Group IIC, IIB, IIA Nonincendive Nonincendive Unclassified Locations or Hazardous (Classified) Locations Class I, Division, Groups A, B, C, D, TCode T Class I, Zone, Group IIC, IIB, IIA, TCode T D00 Associated Apparatus FM Approved under Entity Concept and nonincendive field wiring Unclassified Locations Must not use or generate more than 0 Vrms or Vdc Control Control FM Approved under nonincendive field wiring (permitted only for US installations), or third party approval Power Supply Nonincendive field wiring is not recognized by the Canadian Electrical Code, installation is permitted in the US only. For installation of the unit in a Class I, Division or Class I, Zone location, the wiring between the control equipment and the D00 associated Apparatus shall be accomplished via conduit connections or another acceptable Division, Zone wiring method according to the C and the CEC. Not to be connected to control equipment that uses or generates more than 0 Vrms or Vdc with respect to earth ground. D00 series must be installed, operated and maintained only by qualified personnel, in accordance to the relevant national/international installation standards (e.g. IEC/EN009 Electrical apparatus for explosive gas atmospheres Part : Electrical installations in hazardous areas (other than mines), BS Pt, VDE, ANSI/ISA RP.0.0 Installation of Intrinsically Safe System for Hazardous (Classified) Locations, National Electrical Code C ANSI/NFPA 0 Section 0 and 0, Canadian Electrical Code CEC) following the established installation rules, particular care shall be given to segregation and clear identification of I.S. conductors from non I.S. ones. Deenergize power source (turn off power supply voltage) before plug or unplug the terminal blocks when installed in Hazardous Area/Hazardous Locations or unless area is known to be nonhazardous. Warning: substitution of components may impair Intrinsic Safety and suitability for Division, Zone. Warning: deenergize main power source (turn off power supply voltage) and disconnect plugin terminal blocks before opening the enclosure to avoid electrical shock when connected to live hazardous potential. Explosion Hazard: to prevent ignition of flammable or combustible atmospheres, disconnect power before servicing or unless area is known to be nonhazardous. Failure to properly installation or use of the equipment may risk to damage the unit or severe personal injury. The unit cannot be repaired by the end user and must be returned to the manufacturer or his authorized representative. Any unauthorized modification must be avoided. Operation D00 accepts as an input from Hazardous Area/Hazardous Locations a proximity sensor or voltage free electrical contact and repeats their status to Safe Area/Non Hazardous Locations by a voltage free SPDT relay contact. Presence of supply power and status of output (energized or deenergized), as well as integrity or fault condition of sensor and connecting line are displayed by signaling LEDs (green for power, yellow for status and red for fault condition). D00D (dual channel type) has two independent input channels and actuates the corresponding output relay SPDT contact; two actuation modes can be independently DIP switch configured for each input channel: Normally open input / Normally energized relay or Normally close input / Normally energized relay. Contact or proximity sensor and its connection line short or open circuit fault detection is also DIP switch configurable. Fault detection can be enabled (in case of fault deenergizes the corresponding output channel relay and turns the fault LED) or be disabled (in case of fault the corresponding output channel relay repeats the input line open or close status as configured). D00S (single channel type) has one input channel and two output relays; the unit has two DIP switch configurable operating modes: A) channel actuates in parallel output relays SPDT contacts (providing a DPDT type of output). Relays actuation can be independently configured for each output in two modes: Normally open input / Normally energized relay or Normally close input / Normally energized relay B) channel actuates output relay (A) SPDT contacts configurable in two modes as above. relay B operates as fault output (in case of input fault, relay B actuates and the fault LED turns on while relay A repeats the input line as configured). Actuation can be configured in two modes: No input fault / Energized relay (it deenergizes in case of fault) or No input fault / Deenergized relay (it energizes in case of fault). Note: use of voltage free electrical contacts with fault detection enabled requires, near the switch at the end of the line, a KΩ series connected resistor and a 0 KΩ parallel connected resistor in order to allow the fault detection circuit to distinguish between a condition of contact close/open and a line open/short circuit fault. G.M. International ISM0000 D00 Switch / Proximity Detector Repeater Relay

8 Installation D00 series are switch/proximity detector repeaters housed in a plastic enclosure suitable for installation on T DIN Rail according to EN00. D00 unit can be mounted with any orientation over the entire ambient temperature range, see section Installation in Cabinet and "Installation of Electronic s in Cabinet" Instruction Manual D000 series for detailed instructions. Electrical connection of conductors up to. mm² are accommodated by polarized plugin removable screw terminal blocks which can be plugged in/out into a powered unit without suffering or causing any damage (for Zone or Division installations check the area to be nonhazardous before servicing). The wiring cables have to be proportionate in base to the current and the length of the cable. On the section Function Diagram and enclosure side a block diagram identifies all connections and configuration DIP switches. Identify the number of channels of the specific card (e.g. D00S is a single channel model and D00D is a dual channel model), the function and location of each connection terminal using the wiring diagram on the corresponding section, as an example: Connect Vdc power supply positive at terminal and negative at terminal. For Model D00S connect common relay contact output of channel at terminal, normally closed contact at and normally opened contact at. For Model D00D connect common relay contact output of channel at terminal, normally closed contact at and normally opened contact at. For Model D00S connect proximity sensor or voltage free contact at terminal for positive and for negative. For Model D00D in addition to channel connections above, connect terminal for positive and for negative on channel. Intrinsically Safe conductors must be identified and segregated from non I.S. and wired in accordance to the relevant national/international installation standards (e.g. EN/IEC009 Electrical apparatus for explosive gas atmospheres Part : Electrical installations in hazardous areas (other than mines), BS Pt, VDE, ANSI/ISA RP.0.0 Installation of Intrinsically Safe System for Hazardous (Classified) Locations, National Electrical Code C ANSI/NFPA 0 Section 0 and 0, Canadian Electrical Code CEC), make sure that conductors are well isolated from each other and do not produce any unintentional connection. Connect SPDT relay contacts checking the load rating to be within the contact maximum rating ( A, 0 V, 00 VA 0 W resistive load). The enclosure provides, according to EN09, an IP0 minimum degree of mechanical protection (or similar to MA Standard 0 type ) for indoor installation, outdoor installation requires an additional enclosure with higher degree of protection (i.e. IP to IP or MA type ) consistent with the effective operating environment of the specific installation. Units must be protected against dirt, dust, extreme mechanical (e.g. vibration, impact and shock) and thermal stress, and casual contacts. If enclosure needs to be cleaned use only a cloth lightly moistened by a mixture of detergent in water. Electrostatic Hazard: to avoid electrostatic hazard, the enclosure of D00 must be cleaned only with a damp or antistatic cloth. Any penetration of cleaning liquid must be avoided to prevent damage to the unit. Any unauthorized card modification must be avoided. According to EN00, D00 series must be connected to SELV or SELVE supplies. Relay output contact must be connected to loads non exceeding category I, pollution degree I overvoltage limits. Warning: deenergize main power source (turn off power supply voltage) and disconnect plugin terminal blocks before opening the enclosure to avoid electrical shock when connected to live hazardous potential. Startup Before powering the unit check that all wires are properly connected, particularly supply conductors and their polarity, input and output wires, also check that Intrinsically Safe conductors and cable trays are segregated (no direct contacts with other non I.S. conductors) and identified either by color coding, preferably blue, or by marking. Check conductors for exposed wires that could touch each other causing dangerous unwanted shorts. Turn on power, the power on green led must be lit, status and fault led on each channel must be in accordance with condition of the corresponding input line. If possible close and open input lines one at time checking the corresponding status and fault leds condition as well as output to be correct. Installation in Cabinet Power Dissipation of D00 Isolators Section Technical Data of D00 isolator specifies the current consumption (maximum current from the nominal power supply, typical Vdc, in normal operation); this data serves to dimension the current rating of the power supply unit. Section Technical Data indicates also the maximum power consumption (maximum power required from the power supply in the worst (abnormal) operating conditions like for example supply voltage at 0 Vdc, short circuit on the outputs and on the inputs terminals. The power dissipated Pd inside the enclosure for analog signal isolators is: Pd Current Consumption (A) * Supply Voltage (V) Power Dissipated into the input/output loads Digital signal isolators have lower dissipation than analog signal isolators, in addition channels barriers (D00D) have higher dissipation than single channel units (D00S). Isolators are not running at the maximum current all at the same time, the average power consumption of a multitude of isolators can be considered to be only 0 % of the value obtained from the section Technical Data. Considering the / load power and the 0 % above discussed, the power effectively dissipated internally by the isolators can therefore become ½ of the actual power delivered by the power supply. Digital barriers dissipate all the supply power inside the enclosure consequently the total power dissipation into a cabinet, with mixed analog and digital barriers, is determined by the number of channels more than by the number of isolator enclosures. The following tables give advises for the DIN rail orientation (vertical or horizontal) of the barriers mounting, D00D (double channel) and D00S (single channel) isolators, installed on DIN rail, bus or custom board assembly. A) Cabinet with Natural Ventilation Maximum recommended ambient temperature in C depending on barrier type and installation method: Type of Isolator Single unit Installation Installation of Multiple units with DINrail Bus Installation on Custom Boards Any orientation Vertical Horizontal Vertical Horizontal D00S D00D B) Cabinet with Forced Ventilation Maximum recommended ambient temperature in C depending on barrier type and installation method: Type of Isolator 0 C 0 C C 0 C Not recommended () 0 C () Installation is not recommended since it would significantly shorten the units life and increase the probability of failures. Single unit Installation Installation of Multiple units with DINrail Bus Any orientation Vertical Horizontal C 0 C 0 C C Installation on Custom Boards Vertical Horizontal D00S D00D 0 C 0 C C C 0 C 0 C 0 C C C 0 C D00 Switch / Proximity Detector Repeater Relay G.M. International ISM0000

9 Configuration A configuration DIP switch is located on component side of pcb. This switch allows the configuration of input/output relationship, fault detection functions and operating mode. CH Setting Line fault detection Disabled (contact / proximity sensor) Enabled (proximity sensor or contact with terminating line resistor) IN / OUT Operation or NC NC or NC NC Side A Panel View CH CH Dip switch configuration D00D CH Setting Line fault detection Disabled (contact / proximity sensor) Enabled (proximity sensor or contact with terminating line resistor) IN / OUT Operation or NC NC or NC NC G.M. International ISM0000 D00 Switch / Proximity Detector Repeater Relay 9

10 Configuration Dip switch configuration D00S CH CH Setting Line fault detection Disabled (contact / proximity sensor) Enabled (proximity sensor or contact with terminating line resistor) IN / OUT Operation or NC NC or NC NC B Operation Normal Parallel Mode Out A Out B Reverse Mode Out A Out B Fault Mode No Fault D00D Configuration Summary Table Channel IN/OUT Operation or NC or NC Mode Channel SW SW Line fault detection Disabled (contact/proximity sensor) No Fault Enabled (proximity sensor or contact with terminating line resistor, detects field open circuit and short circuit deenergizing output) SW SW D00S Configuration Summary Table IN/OUT Operation or NC or NC SW Line fault detection Disabled Enabled SW B Operation Normal Fault SW Mode Direct Reverse SW 0 D00 Switch / Proximity Detector Repeater Relay G.M. International ISM0000

D1080D INSTRUCTION MANUAL. D Flammable Liquid Presence Detector Interface Relay Output. DIN-Rail Model D1080D

D1080D INSTRUCTION MANUAL. D Flammable Liquid Presence Detector Interface Relay Output. DIN-Rail Model D1080D D080D INSTRUCTI MANUAL Flammable Liquid Presence Detector Interface Relay Output DINRail Model D080D D080 Flammable Liquid Presence Detector Interface Relay Output ISM00559 Characteristics General Description:

More information

D1080D INSTRUCTION MANUAL. D Flammable Liquid Presence Detector Interface Relay Output. DIN-Rail Model D1080D

D1080D INSTRUCTION MANUAL. D Flammable Liquid Presence Detector Interface Relay Output. DIN-Rail Model D1080D D080D INSTRUCTI MANUAL Flammable Liquid Presence Detector Interface Relay Output DINRail Model D080D D080 Flammable Liquid Presence Detector Interface Relay Output ISM00558 Characteristics General Description:

More information

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069 D09S09 D09D09 INSTRUCTION MANUAL SIL Relay Output Module DINRail Models D09S09, D09D09 D0909 SIL Relay Output Module ISM00 SIL Applications For Safety Related System and SIL, SIL Applications according

More information

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S D109S INSTRUCTION MANUAL SIL Relay Output Module with Line and diagnostics DINRail Model D109S D109 SIL Relay Output Module with Line and diagnostics ISM0096 SIL Applications For Safety Related System

More information

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4

More information

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D D600S - D600D INSTRUCTI MANUAL SIL Switch/Proximity Detector Repeater Relay, DIN Rail, Models D600S, D600D D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0- Characteristics General

More information

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D D603S D603D INSTRUCTI MANUAL SIL 3 Switch/Proximity Detector Repeater Relay, Termination Board Models D603S, D603D D603 SIL 3 Switch/Proximity Detector Repeater Relay G.M. International ISM0400 General

More information

INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D5030S, D5030D D5030S - D5030D.

INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D5030S, D5030D D5030S - D5030D. D00S - D00D HM-0 INSTRUCTI MANUAL SIL Switch/Proximity Detector Repeater Relay, DIN Rail, Models D00S, D00D www.hemomatik.se Ordertel 0-00 0 Växel 0-0 0 Orderfax 0-6 00 Teknisk 0-0 Länna, S- 0 SKOGÅS (Stockholm)

More information

INSTRUCTION MANUAL. SIL 2 Switch / Proximity Detector Repeater, Open Collector Output DIN-Rail and Termination Board, Model D5231E

INSTRUCTION MANUAL. SIL 2 Switch / Proximity Detector Repeater, Open Collector Output DIN-Rail and Termination Board, Model D5231E D5231E INSTRUCTION MANUAL SIL 2 Switch / Proximity Detector Repeater, Open Collector put DINRail and Termination Board, Model D5231E D5231E SIL 2 Switch/Proximity Detector Repeater, O.C. put G.M. International

More information

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S D5090S INSTRUCTI MANUAL 4 A Relay Output Module for NE, DIN-Rail and Termination Board, Model D5090S D5090-4 A Relay Output Module for NE G.M. International ISM09-3 Characteristics General Description:

More information

INSTRUCTION MANUAL. Analog Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1052S, D1052D, D1052X, D1052Y D1052S - D1052D

INSTRUCTION MANUAL. Analog Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1052S, D1052D, D1052X, D1052Y D1052S - D1052D D10S D10D INSTRUCTION MANUAL Analog Signal Converter, Duplicator, Adder/Subtractor DINRail Models D10S, D10D, D10X, D10Y D10 Analog Signal Converter, Duplicator, Adder / Subtractor ISM0011 Characteristics

More information

INSTRUCTION & SAFETY MANUAL

INSTRUCTION & SAFETY MANUAL D5034S D5034D INSTRUCTION & SAFETY MANUAL SIL 3 Switch/ Interface DINRail and Termination Board Models D5034S, D5034D D5034 SIL 3 Switch/ Interface G.M. International ISM01137 Characteristics General Description:

More information

INSTRUCTION & SAFETY MANUAL

INSTRUCTION & SAFETY MANUAL D231E INSTRUCTION & SAFETY MANUAL SIL 2 Switch / Proximity Detector Repeater, Open Collector put DINRail and Termination Board, Model D231E D231E SIL 2 Switch/Proximity Detector Repeater, O.C. put G.M.

More information

INSTRUCTION MANUAL. SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter Din-Rail Model D1064S D1064S

INSTRUCTION MANUAL. SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter Din-Rail Model D1064S D1064S D1064S INSTRUCTION MANUAL SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter DinRail Model D1064S D1064 SIL 2 Load Cell / Strain Gauge Bridge Isolating Converter ISM00888 Characteristics General Description:

More information

INSTRUCTION & SAFETY MANUAL

INSTRUCTION & SAFETY MANUAL D5091S INSTRUCTION & SAFETY MANUAL 5 A SIL 3 Relay Output Module for ND with ND or NE Relay condition DIN-Rail and Termination Board, Model D5091S D5091-5 A SIL 3 Relay Output Module for ND with ND or

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

Zener Barriers Bulletin 937Z

Zener Barriers Bulletin 937Z Technical Data Zener Barriers Bulletin 937Z Topic Page Introduction 2 Mounting 2 Housing 3 Operating Principle 3 Specifications 6 Introduction Allen-Bradley Zener barriers are a cost-effective solution

More information

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015 Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through

More information

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div. Termination Board HiCTB08-SCT-C-SC-RA Features Assembly For 8 modules V DC supply Supported signal types: DI/DO/AI/TI/AO Hazardous area: screw terminals, blue Safe area: screw terminals, black Function

More information

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12 0 4 Remote I/O 8 channels for controlling HART control valves and positioners Intrinsically safe outputs Ex ia IIC Galvanic isolation between outputs and system Open-circuit and short-circuit monitoring

More information

F101, F102, F104. Relcom Installation Instructions. Fieldbus Power Supply F101-PS

F101, F102, F104. Relcom  Installation Instructions. Fieldbus Power Supply F101-PS F101, F102, F104 Fieldbus Power Supply F101-PS Installation Instructions Relcom www.mtl-fieldbus.com CONTENTS PAGE 1 OVERVIEW 2 2 DESCRIPTION 2 3 COMPONENTS AND ACCESSORIES 2 4 MECHANICAL 3 4.1 Mounting

More information

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Safety Manager For 6-channel AI card SAI-60m For 6 modules Recommended module: HiC05 (AI) 4 V DC supply Hazardous area: pluggable screw terminals, blue Non-hazardous

More information

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet Process Automation IS Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to solve the problems associated with the

More information

5 Fieldbus Technology

5 Fieldbus Technology 5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically

More information

Barriers. EB3N Discrete Input Barrier with Redundant Output

Barriers. EB3N Discrete Input Barrier with Redundant Output EB3N Discrete Input Barrier with Redundant Output s Build a safety system in an explosive atmosphere. Key features: Safety Performance Performance level e Category 4 [Exia] II C Ensures safety and machine

More information

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505 Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating

More information

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 1 Series 9475/ www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Universal Safety IO System board for Honeywell Universal Process IO For 6-channel cards USIO and UPIO For 6 modules Recommended modules: HiC8R (DI), HiC85R

More information

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail Switch Amplifier Features Assembly -channel isolated barrier 4 V DC supply (Power Rail) Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL

More information

Operating Instructions

Operating Instructions Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

APPLICATION GUIDE. Interface Modules IM Series.

APPLICATION GUIDE. Interface Modules IM Series. Interface Modules IM Series APPLICATION GUIDE www.turck.com Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to

More information

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail Switch Amplifier KCD-SR-Ex.LB Features Assembly -channel isolated barrier V DC supply (Power Rail) Dry contact or NAMUR inputs Usable as signal splitter ( input and outputs) Relay contact output Fault

More information

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

1/10 SBEx-4S BINARY SEPARATOR with examples of applications 1 OR 2 CHANNELS IN RAIL HOUSING (TS35, width 22,5mm)

1/10 SBEx-4S BINARY SEPARATOR with examples of applications 1 OR 2 CHANNELS IN RAIL HOUSING (TS35, width 22,5mm) ATEX /0 SBEx4S BINAY SEPAATO with examples of applications O CHANNELS IN AIL HOUSING (TS3, width,mm) accompanying device of group I of category (M), group II i III category (), level ia intrinsically safe

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

BA304D Intrinsically safe loop-powered 3½ digit field mounting indicator issue 12

BA304D Intrinsically safe loop-powered 3½ digit field mounting indicator issue 12 BA304D Intrinsically safe loop-powered 3½ digit field mounting indicator issue 12 Issue: 12 25 th September 2008 2 CONTENTS 1. Description 2. Operation 3. Intrinsic Safety Certification 3.1 ATEX certificate

More information

MACX MCR-EX-SL-NAM-2RO(-SP)

MACX MCR-EX-SL-NAM-2RO(-SP) Intrinsically safe NAMUR isolating amplifier with two relay outputs INTERFACE Data sheet 03465_en_00 PHOENIX CONTACT - 08/008 Description The NAMUR MACX MCR-EX-SL-NAM-RO(-SP) isolating amplifier has been

More information

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni) Data sheet 302040_en MTP300i-SIL-K Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni) Properties 2-wire temperature transmitter for DIN rails Galvanic isolated TC-input with cold-junction compensation

More information

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description Active resistance thermometer measuring transducer Data sheet 099_en_06 PHOENIX CONTACT 0-0- Description The 6. mm wide MINI MCR-SL-PT00-UI-... is a configurable, -way isolated temperature measuring transducer.

More information

MACX MCR-EX-SD LP(-SP)

MACX MCR-EX-SD LP(-SP) Intrinsically safe solenoid driver for Group IIC gases, loop-powered, current limit 48 ma INTERFACE Data sheet 103468_en_01 PHOENIX CONTACT - 08/2008 1 Description The solenoid driver MACX MCR-EX-SD-24-48-LP(-SP)

More information

MACX MCR-EX-SL-NAM-R(-SP)

MACX MCR-EX-SL-NAM-R(-SP) Intrinsically safe NAMUR isolating amplifier with relay output INTERFACE Data sheet 03463_en_00 PHOENIX CONTACT - 08/2008 Description The NAMUR MACX MCR-EX-SL-NAM-R(-SP) isolating amplifier has been designed

More information

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F 4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to

More information

MINI MCR-SL-PT100-UI-200

MINI MCR-SL-PT100-UI-200 Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is

More information

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F 4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i / I.S. solenoid valves, piezo and booster valves Intrinsically safe outputs Ex ia IIC Additional input for "Outputs OFF" available

More information

MINI MCR-SL-PT100-UI(-SP)(-NC)

MINI MCR-SL-PT100-UI(-SP)(-NC) Configurable Temperature Transducer for PT100 Data Sheet 04/2005 Functions MINI MCR-SL-PT100-UI(-SP)(-NC) is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

Discrete Output Modules

Discrete Output Modules Important Product Information Discrete Output Modules GFK-2764C Aug 2017 May 2017 Before using the units: To use the units safely and effectively, please read this document and refer to GFK-2745 & network

More information

MANUAL Surge Protectors

MANUAL Surge Protectors PROCESS AUTOMATION MANUAL Surge Protectors DP-LBF-I1.36.DE and DP-LBF- I1.36.IE With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 05/2007 Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007

More information

DeltaV Bulk Power Supplies

DeltaV Bulk Power Supplies DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to

More information

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.: Extract from the online catalog MINI MCR-SL-UI-2I-NC Order No.: 2864176 4-way signal duplicator for electrical isolation and duplication of analog signals with screw connection, standard configuration

More information

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250 PSS 1250 Characteristics: General Description: The Power Supply System type PSS1250 is an anodized aluminum 19 Rack unit (4U high) suitable to accept up to 6 plugin Power Supply Modules type and 1 Overview

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250 Characteristics: Features: PSS 1250 General Description: The Power Supply System type PSS1250 is an anodized aluminum 19 Rack unit (4U high) suitable to accept up to 6 plugin Power Supply Modules type

More information

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250 Characteristics: PSS 1250 General Description: The Power Supply System type PSS1250 is an anodized aluminum 19 Rack unit (4U high) suitable to accept up to 6 plugin Power Supply Modules type and 1 Overview

More information

Intrinsically Safe Explosion Proof Barriers

Intrinsically Safe Explosion Proof Barriers Safety Intrinsically Safe Explosion Proof For more information on this product family, visit our website. Additional resources include: New and updated product information Downloadable software demos &

More information

ETD-BL-1T-OFF-CC- 10S

ETD-BL-1T-OFF-CC- 10S Timer relay with off delay (with control contact) and adjustable time Data sheet 103617_en_03 1 Description PHOENIX CONTACT - 2013-09-16 Features Compact timer relay in 6.2 mm housing for controlling time

More information

MINI MCR-SL-CVS NC

MINI MCR-SL-CVS NC Constant voltage source Data sheet 105264_en_01 PHOENIX CONTACT 2013-04-03 1 Description Configurable constant voltage source for generating highprecision constant voltages. The voltage supply is also

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

Inductive sensor with analog output BI15-M30-LI-EXI

Inductive sensor with analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection

More information

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001 PROCESS AUTOMATION MANUAL Z-System Zener Barriers ISO9001 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and

More information

DeltaV Bulk Power Supplies

DeltaV Bulk Power Supplies DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to

More information

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

Safety instructions. IECEx TUN Ex ia IIC T6 Gb Safety instructions ÜSB62-36G.C_* and ÜSB62-30W.C_* IECEx TUN 07.0002 Ex [ia Ga] IIC T6 Gb Ex ia IIC T6 Gb 0044 39878 Content 1 Area of applicability 3 2 General 3 3 Electrical data 3 3.1 Application conditions

More information

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur. egment Protector for Cabinet nstallation Features Assembly 4... 12 outputs Ex ic (FCO or Entity) or non-incendive (Div 2) Advanced fault isolation at the spur egment Protector in Zone 2/Div. 2 nstruments

More information

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description I/O extension module, 4 digital relay outputs INTERFACE Data sheet 104834_en_01 PHOENIX CONTACT 2013-01-21 1 Description The RAD-DOR4-IFS I/O extension module can be used in conjunction with Radioline

More information

BA488CF-P PROFIBUS PA Intrinsically safe Panel mounting Fieldbus Display issue 3

BA488CF-P PROFIBUS PA Intrinsically safe Panel mounting Fieldbus Display issue 3 TR Automatyka Sp. z o. o. Tel. (+48 022) 886 10 16 www.trautomatyka.pl ul. Lechicka 14 ; 02-156 Warszawa Fax. (+48 022) 846 50 37 biuro@trautomatyka.pl BA488CF-P PROFIBUS PA Intrinsically safe Panel mounting

More information

M E M O R A N D U M I.S.

M E M O R A N D U M I.S. Physikalisch-Technische Bundesanstalt Department 3.6 " Intrinsic safety and Safety of Systems" 38023 Braunschweig Germany P.O. Box 33 45 Tel. ++49 531 592-3630 Fax ++49 531 592-3605 M E M O R A N D U M

More information

The 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel.

The 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel. February 23, 2018 Annexe to: IECEx CML 15.0097X Issue 4 Applicant: Apparatus: HMI Elements Limited 470-Z1 Module Description of Equipment The 470-Z1 is a mains supplied, transportable hazardous area

More information

Startup instructions. AutoConfiguration Adapter ACA21-USB (EEC) ACA22-USB (EEC) ACA21-M12 (EEC) ACA22-M12 (EEC)

Startup instructions. AutoConfiguration Adapter ACA21-USB (EEC) ACA22-USB (EEC) ACA21-M12 (EEC) ACA22-M12 (EEC) Startup instructions AutoConfiguration Adapter ACA21-USB (EEC) ACA22-USB (EEC) ACA21-M12 (EEC) ACA22-M12 (EEC) Release 02 04/2014 Technical Support https://hirschmann-support.belden.eu.com The naming of

More information

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E Table of contents 1. INTRODUCTION...1 2. HARDWARE DESCRIPTION...2 3. INSTALLATION...6 4. CONNECTION...8 5. USER SAFETY AND PROTECTION OF THE EQUIPMENT...11

More information

Safety instructions VEGATOR 121, 122

Safety instructions VEGATOR 121, 122 Safety instructions Intrinsic safety IECEx TUN 14.0005X Document ID: 47471 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Installation... 4 Supplementary documentation:

More information

INSTRUCTION & SAFETY MANUAL

INSTRUCTION & SAFETY MANUAL ISTRUCTIO & SAFETY MAUA SI3 Power Supply, 24Vdc, 50 A, Zone 2 / Division 2 Wall Mounting SI 3 Power Supply, 24Vdc, 50 A, Zone 2 / Division 2 G.M. International ISM02206 General Description: The Power Supply

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

Intrinsically Safe Barriers

Intrinsically Safe Barriers Intrinsically Safe Barriers Description Page No. Safety Barriers 464-472 Din Rail Isolated Barriers 473-488 477 Intrinsically Safe Barriers Product Overview We have simplified intrinsic safety! Cooper

More information

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC Characteristics multifunction phase control relay RM35-T - range 194..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC Characteristics phase control relay RM17-T - range 183..484 V AC Complementary Maximum switching voltage Minimum switching current [Us] rated supply voltage Supply voltage limits Control circuit voltage

More information

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions Evaluation system for flow sensors VS / / 2013 Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Installation & Operation Manual

Installation & Operation Manual Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas

More information

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur. egment Protector for Cabinet nstallation Features Assembly 4... 12 outputs Ex ic (FCO or Entity) or non-incendive (Div 2) Advanced fault isolation at the spur egment Protector in Zone 2/Div. 2 nstruments

More information

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017 November 2017 Module Status LED Channel Status LEDs Digital Input Connector Ground 24 V DC FE Analog Input Module RSTI-EP Slice I/O Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704,

More information

Explosion Proof I/P Transducer

Explosion Proof I/P Transducer Type 950XP Explosion Proof I/P Transducer Installation, Operation and Maintenance Instructions 2" Pipe A 1 1/2" Pipe (49.5) 0 (88.9) (25.4) Holes for Mounting 1/2 NPT/M20 ("K" option) Port for Conduit

More information

M-series Intrinsically Safe I/O

M-series Intrinsically Safe I/O DeltaV Distributed Control System Product Data Sheet M-series Intrinsically Safe I/O Features full system modularity Reduces system footprint Decreases installation time and expense Plug-and-play installation

More information

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2 Technical Data Communication Adapter Catalog Number 1719-AENTR I/O Module Catalog Numbers 1719-IJ, 1719-IBN8B, 1719-IF4HB, 1719-IR4B, 1719-IT4B, 1719-OB2, 1719-OB2L, 1719-CF4H Power Supply Catalog Number

More information

Trendmaster* Galvanic Isolator

Trendmaster* Galvanic Isolator 162459-01 Trendmaster* Galvanic Isolator Product Datasheet Bently Nevada* Asset Condition Monitoring Description The Trendmaster Galvanic Isolator enables the Trendmaster system to connect to intrinsically

More information

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS GB Contents Page 1 Introduction 4 2 Safety 5 3 Use 6 4 Checking on Delivered Equipment 6 5 General Specification and Dimensions 7 6 Positioning 10 7 Operating

More information

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks Sensor boxes SRBC q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity

More information

Micro Motion, Inc. Page 1 of 6

Micro Motion, Inc. Page 1 of 6 EB-20025742 Revision: AA Number of Pages: 6 Comments: Originator: HVH 10/01/13 Approved: RCS 11/26/13 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 11/26/13 Micro Motion, Inc. Page

More information

SMARTLINE RM76 Supplementary instructions

SMARTLINE RM76 Supplementary instructions SMARTLINE RM76 Supplementary instructions 2-wire / Guided Radar (TDR) Level Meter Supplementary Instructions for ATEX applications CONTENTS SMARTLINE RM76 1 General safety information 5 1.1 Scope of the

More information