1 Installation Instructions Model LPB Local Page Board ( / S24235-B5-A2) INTRODUCTION The LPB (Local Page Board) is used to connect the alarm microphone, mounted in the LVM (Live Voice Microphone), and the voice system internal telephone system. The LPB converts the two analog input signals into the system's internal digital format. Additionally the LPB provides one analog output to connect the monitor speaker, mounted in the LVM. This output signal is 1 of the 8 voice internal audio channels selectable at the voice control panel. The microphone signal wiring between LVM and LPB is supervised. The microphone audio input of the LPB is not transformer isolated (each LVM microphone output is transformer isolated). The audio input from the telephone riser is transformer isolated. Each of the three audio channels can be configured independently via the Zeus tool. Each audio channel can be controlled automatically via the system logic, dependant on its individual configuration or manually by using the voice control panel During the initial power-up condition, each of the three audio channels are shut off. Features LPB features are as follows: General Up to 5 LVMs can be connected to the LPB (only one can be active at a time) Control data via CAN protocol Digital audio connection with ASI protocol Figure 1: DAC-NET Front panel with LPB 1 s
2 Analog audio input to connect LVM microphone Wiring between LPB and LVM is supervised for shorts and opens in the inactive state Audio input supervised for Loss of Signal in the active state Separate analog digital converter Optional audio data Compression, selectable via Zeus tool Analog audio input to connect the internal telephone system Audio input transformer isolated Audio input supervised for Loss of Signal in the active state Separate analog digital converter Optional audio data Compression, selectable via Zeus tool Analog audio output to connect LVM monitor speaker Digital analog converter Optional audio data Decompression, selectable via Zeus tool OPERATION The LPB contains two audio input circuits and one audio output circuit. The inputs are supervised for presence of input signal in the active state. The LPB provides sampling rates from 12kHz to 48kHz and resolution from 8bit to 16bit separately for each audio channel. Optionally, the digital audio data can be compressed/de-compressed separately for each input and output. Reduction of sampling rate and resolution together with data compression is only needed in applications with distributed system architecture where D- NET (external digital bus to connect voice transponders) is needed. Centralized voice systems with only one single transponder (no D-NET) will always have the maximum audio quality: 48kHz sampling rate, 16bit resolution and no data compression. The LPB is a plug-on-board to the DAC-NET. The LPB indicates its status by diagnostic LEDs. Controls and Indicators The LPB has no front panel. It uses the front panel of the DAC-NET. It contains the following: One RESET switch Eight diagnostic LEDs to indicate the operation of the card as shown in Figure 1 The reset switch is located on the top of the front panel. Pushing the reset switch re-initializes the LPB operation. 2
3 NAME COLOR NORMAL STATE The diagnostic LEDs are placed under the reset switch. Their function is defined as follows: WHEN ILLUMINATED POWER green ON indicates that power for the LPB is applied to the card LPB FAIL yellow OFF indicates a general trouble at LPB failure on LPB CAN FAIL yellow OFF indicates that the CAN communication has terminated and the card operates in degrade mode ASI FAIL yellow OFF indicates that the ASI communication has stopped and the card operates in degrade mode Microphone Active green OFF indicates that the microphone audio input is active Microphone Trouble yellow OFF indicates that the LPB has detected a trouble on the microphone input Phone Active green OFF indicates that the telephone audio input is active Speaker Active green OFF indicates that the speaker audio output is active ACTION IN OFF NORMAL STATE failure on LPB, PSC, DAC,- NET CC5, backplane or wiring failure on LPB, DAC-NET, CC5, backplane or other CAN Cards failure on LPB, DAC-NET, CC5, backplane or other ASI Cards Paging audio is available to the system Microphone input 1, open, short or no signal Telephone audio is available to the system. Speaker plays the selected audio channel. WIRING Remove ELECTRICAL POWER prior to working on equipment. The field wiring of the LPB is connected to the terminal blocks of the PSC-12. EOL attachment The Analog Audio Bus includes three audio signals (LVM microphone, LVM monitor speaker, FMT Phone). The LPB supervises the microphone signal wiring to the LVM. The supervision requires an EOL resistor 3K3. The EOL is set with P7 at the LVM. If one LVM is mounted the jumper P7 must be set in position 1 2. If more than one LVM is mounted the Jumper P7 of the last LVM must be set in position 1 2. The Jumper P7 of the other LVMs must be set in position 2 3. LVM default factory setting: Jumper P7 in position 1 2 For further information refer to DAC-NET Installation Instructions, Order No. A24205-A334-B839 3
4 INSTALLATION The LPB is a Plug-on-board to a DAC-NET. The LPB is delivered with the spacers mounted on the LPB, four Panhead screws M3 x 6 and 4 washers 3.2mm to mount the LPB on the DAC-NET. The LPB and DAC-NET are assembled in such a way that the component sides face each other. The spacers of the LPB must be fit into with the holes on the DAC-NET. To install the LPB, hold it at an angle to the DAC-NET with the LEDs pointing towards the front panel of the DAC-NET. LPB DAC-NET Figure 2: Installing the LPB Rotate the LPB towards the DAC-NET while ensuring that the pins of the LPB align with the sockets on the DAC-NET. DO NOT FORCE the LPB card. LPB Connectors DAC-NET Figure 3: Connectors of LPB 4
5 Secure the LPB on the DAC-NET`s solder side with four screws. Figure 4: Securing the LPB Installation of the DAC-NET with LPB in CC-5/CC-2 Figure 5: Installing the DAC-NET with the LPB Insert the DAC-NET card with the LPB on it into the card guides rightside up (lettering on the front panel is legible). Slide the card in until the card edge connectors contact the receptacles on the motherboard. Verify that the DIN connectors of the card and the cardcage aligned properly. The card can only plug in one direction to the card cage, if it does not align, DO NOT FORCE the card. Place thumbs on the front panel adjacent to the captive screws and gently apply even pressure on the card until the connectors seat in the receptacles on the motherboard. Secure with the captive screws. Power up the system and verify that the LPB power LED turns ON. 5
6 ELECTRICAL RATINGS Power Consumption LPB 24V Back Plane Current 25mA Screw Terminal 24V Current 0 6.2V Back Plane Current 95mA + 35mA per Active Channel 24V Standby Current 50mA Microphone Wiring Supervision EOL 3.3K Voltage nom / max Supervision current nom / max 15V / 24V 5mA / 15mA For CE applications in Cerberus E100 systems refer to Installation Instruction A24205-A334-B844 (English) or A24205-A334-A844 (German) Siemens Gebäudesicherheit GmbH & Co. ohg 2002 Siemens Building Technologies, Inc. Florham Park, New Jersey Siemens Building Technologies, Ltd. Brampton, Ontario L6T 5E4 CN Issued by Siemens Gebäudesicherheit GmbH & Co. ohg D München Delivery subject to availability; right of technical modifications reserved. Order No. A24205-A334-B836 (Edition 1) Printed in the Federal Republic of Germany on environmental chlorine-free paper.
Installation Instructions Models CC-5 / CC-2
Installation Instructions Models CC-5 / CC-2 System Cardcage CC-5 (500-633037 / S24235-B123-A1) System Cardcage CC-2 (500-633440 / S24235-B122-A1) INTRODUCTION The SIEMENS Model CC-5 Cardcage (see Figure
More informationInstallation Instructions Model PSX-12
Installation Instructions Model PSX- Amp Power Supply Extender INTRODUCTI The SIEMENS Model PSX- is a high current power supply extender. The power supply extender works in conjunction with the PSC- power
More informationInstallation Instructions Model PSC-17C
Installation Instructions Model PSC-17C 17 Amp Power Supply INTRODUCTION The Model PSC-17C from Siemens Industry, Inc. is a high current power supply that provides the Fire Alarm system (Sprachalarmsystem
More informationInstallation Instructions Model ZAM-180
s Installation Instructions Model ZAM-80 Zone Amplifier Module 80W (500-035600 / S24235-B6-A5 (70V)) Installation Instructions for North America INTRODUCTION The Model ZAM-80 from Siemens Industry, Inc.
More informationINSTALLATION INSTRUCTIONS Model VCC2002-A1 Voice input/output Card
INSTALLATION INSTRUCTIONS Model VCC2002-A Voice input/output Card The Model VCC2002-A Voice I/O card is installed into the FV2025/2050 Fire Voice Control Panel of the FS20 system. Together with the VCC200-A
More informationInstallation Instructions Model FMT
Installation Instructions Model FMT Fireman s Master Telephone ITRODUCTI The Model FMT Fireman s Master Telephone from Siemens Industry, Inc. provides firefighters with an emergency telephone system for
More informationInstallation Instructions Models FCM-6 / LCM-8 / SCM-8 Model CSB
Installation Instructions Models FCM- / LCM- / SCM- Model CSB Control Module / LED Control Module / Switch Control Module CAN Sounder Board INTRODUCTION The Models FCM-, LCM- and SCM- from, are similar
More informationInstallation Instructions Model RNI
Installation Instructions Model Remote Network Interface INTRODUCTION The IEMEN Model allows for the remote installation of the PMI-REM, D-C-REM (on HNET) and the LCM-/CM-/FCM-/IM-/OCM- (on CAN) modules.
More informationInstallation Instructions Model NIC-C
nstallation nstructions Model Network nterface Card NTRODUCTON The Model from, is a card that provides HNET/XNET and CAN network communication within and between enclosures. The HNET/XNET network can be
More informationINSTALLATION INSTRUCTIONS Model VTO2001-U2/U3 Option Module (24 Switches)
INSTALLATION INSTRUCTIONS Model VTO2001-U2/U3 Option Module (24 Switches) The Model VTO2001-U2/U3 Option Module (24 Switches) illustrated in Figure 1 is installed in the FV2025/2050 Fire Voice Control
More informationCerberus Division. Installation Instructions CERBERUS PYROTRONICS TM Model RDM-MXL. (Remote Diagnostics Module)
Cerberus Division Installation Instructions CERBERUS PYROTRONICS TM Model RDM-MXL Remote Diagnostics Module INTRODUCTION The CERBERUS PYROTRONICS TM Model RDM-MXL module (RDM for connection to the MXL
More informationInstallation Instructions Model SNC Serial Network Card for USB Application with Windows
Installation Instructions Model SNC Serial Network Card for USB Application with Windows OPERATION The Model SNC from Siemens Industry, Inc. (as shown in Figure 1) is a USB-compliant network card used
More informationMCS 50. Discussion Control Unit. 1 of 7
Discussion Control Unit FEATURES One microphone line for a maximum of 32 microphone units Integrated power supply unit with control for up to 32 microphone units Can be expanded to 64 microphone units
More informationAudio Input Card Installation Instructions
Installation Instructions Introduction This publication describes the installation procedure for the 4100-1240. This card is compatible with 4100U and 4100ES Fire Alarm Control Panels. In this Publication
More informationINSTALLATION INSTRUCTIONS Model VCA2002-A1 Card Cage
INSTALLATION INSTRUCTIONS Model VCA2002-A1 Card Cage The Model VCA2002-A1 Card Cage assembly is installed in the FV2025/2050, FV922/FV924 Fire Voice Control Panel of the FS20 system to house and interconnect
More informationHauptwerk Hardware 2016
Hauptwerk Hardware Interface Board for the Universal Midi Encoder User Manual Page 1 Release 1.2 February 2016 Table of Contents Introduction...3 Board Overview...4 IMPORTANT PLEASE READ...5 Mounting...6
More informationConnecting a Cisco Input Module
CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each
More informationTechnical Datasheet clima RCM-CC
Technical Datasheet 1. Product description The is a room control panel with an integrated temperature sensor for measuring the room temperature. The device is featured with a turn wheel to adjust the set
More informationCustom O2+ODAC Soldering Instructions
Custom O2+ODAC Soldering Instructions Preparations The following components should be omitted during basic assembly: R1, R2 D2, D6 BT2 The following components should be omitted based on required customization:
More informationINTEGRUS BOSCH DIGITAL INFRA-RED LANGUAGE DISTRIBUTION SYSTEM. Installation and Operating Manual
INTEGRUS DIGITAL INFRA-RED LANGUAGE DISTRIBUTION SYSTEM Installation and Operating Manual LBB 3222/04 6-Channel Interpreter Desk with Loudspeaker LBB 3422/10 Symmetrical Audio Input and Interpreters Module
More information9109 FXS Analog Voice Application Module (APM) Installation Instructions. Product Documentation on the World Wide Web
TM 9109 FXS Analog Voice Application Module (APM) Installation Instructions Document Number 9109-A2-GN12-40 May 1999 Product Documentation on the World Wide Web We provide complete product documentation
More informationINTEGRUS. LBB 3222/04 6-Channel Interpreter Desk with Loudspeaker. LBB 3422/20 Integrus Audio Input and Interpreters Module
INTEGRUS en Installation and User Instructions Integrus Language Distribution System LBB 3222/04 6-Channel Interpreter Desk with Loudspeaker LBB 3422/20 Integrus Audio Input and Interpreters Module INTEGRUS
More informationFigure 36. Connecting the 24V/DC power supply
5.5.1 Connecting the 24Vdc Power Supply The 24Vdc power supply uses a 2-pole connection terminal as described in section 5.4.2 on page 33. The connection point on the room controller circuit board for
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS MicroComm DXI. Intent & Scope This document describes the installation procedure for the IMS-30 Intercom Master Station and the MAI-420 or MAI-20 Master Audio Interface. The earliest
More informationRCM-810. Technical specifications. Electro-Voice RCM-810. Enable powerful control and supervision capabilities
Electro-Voice RCM-0 RCM-0 Enable powerful control and supervision capabilities Integrate up to 00 devices in each remote control network, 50 with multiple networks Freely programmable control inputs and
More informationFLEX Ex Spring Clamp Terminal Base
Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification
More informationChenbro. ES34169 Chassis User s Manual. April / 2 /
Chenbro ES34169 Chassis User Manual April / 2 / 2010 www.chenbro.com 1 Copyright Copyright 2007 Chenbro Micom Co., Ltd.. All rights reserved. Unless otherwise indicated, all materials in this manual are
More informationLCD Meter for Model 3051 Pressure Transmitters English Rev. AA
LCD Meter for Model 3051 Pressure Transmitters 00809-0300-4001 English Rev. AA CONTENTS Before you Install the Meter Kit...................... 3 Overview....................................... 5 Safety
More informationABB Drives. User s Manual Pulse Encoder Interface Module MTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module MTAC-01 Pulse Encoder Interface Module MTAC-01 User s Manual 3AFE68591091 REV B EN EFFECTIVE: 04.04.2006 2006 ABB Oy. All Rights Reserved. 5 Safety
More information256 Kbytes (1771-DRS) 1 Mbyte (1771-DRS1) 4 Mbytes (1771-DRS4) Installation Data
Installation Data You can add static RAM memory to your control coprocessor main module to expand user memory. The RAM single inline memory module (SIMM) is available in the following sizes: 256 Kbytes
More informationMicrosystems. SCI-6 Sound Card Interface Kit Version 1.09 January 2015
UM Unified Microsystems SCI-6 Sound Card Interface Kit Version 1.09 January 2015 The SCI-6 interface was designed to be a low cost, high quality interface between your PC s sound card and radio transceiver.
More informationPSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B
Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits
More informationTechnical Data. C-DIAS-MULTI l/o MODULE CIO 013
C-DIAS-MULTI l/o MODULE CIO 013 C-DIAS-Multi I/O Module CIO 013 6 x digital inputs (+24V, 5mA, 5ms) input 3 useable as interrupt (+24V, 5mA, 10 s) 2 x digital counter inputs (+5V, 5mA, 1 s) 8 x digital
More informationHARDWARE OPERATIONS MANUAL
HARDWARE OPERATIONS MANUAL Table of Contents INTRODUCTION... 2 SECTION 1: HARDWARE COMPONENT ASSEMBLIES... 2 MECHANICAL HARDWARE AND CASE... 2 PCB ASSEMBLY... 4 ISD RECORDING CIRCUIT... 5 BREADBOARD ASSEMBLY...
More informationInstalling Sentor. Hardware Installation
Remote base site monitoring and control Installing Sentor Hardware Installation Copyright 2000 Sentor Monitoring Systems Pty Ltd Contents: 1 Introduction... 1 2 Sentor GUI... 2 3 ST3000 Controller... 3
More informationZEUS Series: microzeus with Flying Bus Boards
ZEUS Series: microzeus with Flying Bus Boards Zeus Series: microzeus with Flying Bus Boards The uzeus is a 4HP power supply module for Eurorack format synthesizers. This version comes with two (2) flying
More informationCONTENTS. 1. Motherboard installation Install 5¼ and 3½ drives Install PCI components Case fan setup...5
USER S MANUAL CONTENTS 1. Motherboard installation...1 2. Install 5¼ and 3½ drives...3 3. Install PCI components...4 4. Case fan setup...5 5. Connect case leads to motherboard...6 6. Identify the power
More information2562 QUICK START GUIDE
2562 QUICK START GUIDE CTI P/Ns: 2562 Quick Start Guide: 062-00348-010 2562 Installation and Operation Guide: 062-00332-011 Summary: The 2562 is designed to translate a digital word from the programmable
More informationu::lux Switch RJ45 Manual u::lux Switch RJ45 Manual Tel: +43/662/ Fax: +43/662/
u::lux Switch RJ45 Manual www.u-lux.com office@u-lux.com Tel: +43/662/450 351-13 Fax: +43/662/450 351-16 u::lux GmbH Rechtes Salzachufer 42 5020 Salzburg Austria Page: 1/11 Contents Installation... 3 Installation
More informationUpsampling Upgrade for the LINK DAC III Rev #7 (3/2006) Users Manual
Upsampling Upgrade for the LINK DAC III Rev #7 (3/2006) Users Manual Thank you for purchasing the Upsampling Upgrade for your LINK DAC. I am sure you will be very pleased with it. It adds the following
More informationA2K. Absolute Optical Encoder: Kit Version Page 1 of 7. Description. Features
Description Page 1 of 7 The A2K optical encoder is a 12 bit absolute rotary kit style encoder which reports a shaft angle within a single 360 degree rotation of a shaft. The kit style A2K allows the encoder
More informationG80 MULTIGAME/SPEECH/SOUND INSTALL GUIDE
G80 MULTIGAME/SPEECH/SOUND INSTALL GUIDE The G80 MultiGame kit includes the items pictured above. 1. Main PWA 2. Spinner PWA 3. Wire Harness Interface PWA 4. 48 34 conductor ribbon cable 5. 3 pin connector
More informationAssembly Instructions for the KA Electronics Elliptic Equalizer
Assembly Instructions for the KA Electronics Elliptic Equalizer Install IC sockets Elliptic Equalizer PC Board Stuffing Guide Place the PC Board on the work bench silkscreen side face up. Place twelve
More informationPandora Assembly Instructions With Diamond Systems PC/104 CPUs (Athena, Elektra and Prometheus) November, 2006
Pandora Assembly Instructions With Diamond Systems PC/104 CPUs (Athena, Elektra and Prometheus) November, 2006 Diamond Systems Corp. (650) 810-2500 www.diamondsystems.com This document describes how to
More informationCONTROL MICROSYSTEMS Analog Output Module. Hardware Manual
5304 Analog Output Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support:
More informationData sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC
Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC ERP no.: 5206415 GCM MOD GMM EC.1 www.guentner.de Page 2 / 15 Contents 1 GCM MOD GMM EC.1...3 1.1 Functional description...3 1.2 Connections...
More informationRASPBERRY PI MEGA-IO EXPANSION CARD USER'S GUIDE VERSION 2.3
RASPBERRY PI MEGA-IO EXPANSION CARD www.sequentmicrosystems.com USER'S GUIDE VERSION 2.3 GENERAL DESCRIPTION... 2 BOARD LAYOUT... 3 BLOCK DIAGRAM... 4 COMPONENT DESCRIPTION... 5 CONFIGURATION JUMPERS...
More informationVertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1
15370 Barranca Parkway Irvine, CA 92618 USA VertX V100, V200 and V300 Installation Guide November 2011 6080-930 Rev A.1. Contents Introduction... 3 Parts List... 3 Product Specifications... 3 Cable Specifications...
More informationGSV-1A4 M12/2 M12/2. Highlights
GSV-1A4 M12/2 M12/2 Highlights Input sensitivity: 2mV/V; 4mV/V, 2 mv/v, 1mV/V, 0.5mV/V configurable via jumpers Output signals ±10V AND 12mA+-8mA on 15 pin Sub-D Integrated half and quarter bridge completion
More information5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
5B Series 16 Channel Backplane 5B01 FEATURES Mix and Match 5B Series I/O Module Capability Factory Mutual (FM) Approved Approved for Use in Class I, Division2, Groups A, B, C, and D Locations. CE Certified:
More informationBasler Accessories. Technical Specification dart I/O BOARD
DRAFT Basler Accessories Technical Specification dart I/O BOARD Order Numbers 106896 dart I/O Board Starter Kit 106897 dart I/O Boards (5 Pieces) 2000035665 dart I/O Board Mounting Kit Document Number:
More information2005 Pioneer Home Audio Seminar VSX49TX
2005 Pioneer Home Audio Seminar VSX49TX Pioneer Electronic Service, Inc. 2005 Introduction Why the VSX49TX? The VSX49TX is not current product, however it tends to be the most difficult to repair! What
More informationBLUETOOTH AMPLIFIER KIT
PRODUCT INFORMATION BUILD INSTRUCTIONS CHECKING YOUR PCB & FAULT-FINDING MECHANICAL DETAILS HOW THE KIT WORKS CREATE YOUR OWN WIRELESS SPEAKER WITH THIS BLUETOOTH AMPLIFIER KIT Version 1.2 Index of Sheets
More informationUser s Manual Pulse Encoder Interface Module OTAC-01
Drive IT Low Voltage AC Drives User s Manual Pulse Encoder Interface Module OTAC-01 2 Safety WARNING! All electrical installation and maintenance work on the drive should be carried out by qualified electricians
More informationRoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e
The Sendix multiturn encoders 5862 and 5882, with SSI or RS485 interface and combined optical and magnetic sensor technology, offer a maximum resolution of 25 bits. These encoders are programmable via
More informationThe Single Dimmer Board
The Single Dimmer Board Introduction This electronic system has been designed as an interface unit between a Cronapress illuminated press strip and an external system such as a security alarm system; a
More informationDIN-RAIL EXPANDER int-iors_en 10/14
INT-IORS INT-ORS DIN-RAIL EXPANDER int-iors_en 10/14 The INT-IORS expander enables the system to be expanded by 8 programmable wired zones and 8 programmable wired outputs. The INT-ORS expander enables
More informationAmphenol. 608 Series. Amphenol Limited. Design Features. Circular Environmental Connectors Approved to BS9522 F0020 (Pattern 608)
Amphenol 608 Series Circular Environmental Connectors Approved to BS9522 F0020 (Pattern 608) CE30 Design Features Keyway Polarisation. Ni Aluminium Bronze Shells. Threaded Anti Vibration coupling mechanism.
More informationWeb Site: Forums: forums.parallax.com Sales: Technical:
Web Site: www.parallax.com Forums: forums.parallax.com Sales: sales@parallax.com Technical: support@parallax.com Office: (916) 624-8333 Fax: (916) 624-8003 Sales: (888) 512-1024 Tech Support: (888) 997-8267
More informationControl Head for the integrated mounting on process valves
Control Head for the integrated mounting on process valves Type 8691 can be combined with Compact stainless steel design Integrated analogue valve position registration (Teach function) Coloured illuminated
More informationTrueNAS Z SERIES NODE SATADOM REPLACEMENT KIT. August 2017 Edition
TrueNAS Z SERIES NODE SATADOM REPLACEMENT KIT August 2017 Edition Table of Contents Introduction... 1 Preparation... 1 Non-HA Systems Without Failover... 2 HA Systems with Failover... 2 Determine the Active
More informationCONTROL MICROSYSTEMS High Speed Counter Input Module. Hardware Manual
50 High Speed Counter Input Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support: -6-676
More informationControl Head for the integrated mounting on process valves
Control Head for the integrated mounting on process valves Type 8695 can be combined with Compact stainless steel design Integrated analog valve position registration (Teach function) Coloured illuminated
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationFVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL
2-CHANNEL 10-BIT DIGITALLY ENCODED VIDEO + 2 BI-DIRECTIONAL DATA + AIPHONE INTERCOM + 4 CONTACT CLOSURE + 100MB ETHERNET + REDUNDANT POINT-TO-POINT DUAL SFP OPTICAL PORTS The series utilize 10-bit digital
More informationBIG8051. Development system. User manual
BIG8051 User manual All s development systems represent irreplaceable tools for programming and developing microcontroller-based devices. Carefully chosen components and the use of machines of the last
More informationSection 5: Installing Parts from the Controls and Connectors Bag
Section 5: Installing Parts from the Controls and Connectors Bag 1) Install Pinheaders & Sockets Using the Component Layout Diagram in Appendix A as a guide, install all pinheaders and strip sockets on
More informationPanorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer
USER'S MANUAL Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer DEIF A/S Frisenborgvej 33 DK-7800 Skive
More informationAUTROVOICE MULTIVES EXCHANGEABLE MODULES
AUTROVOICE MULTIVES EXCHANGEABLE MODULES Voice alarm system Product Datasheet Logical input card for control slots ABT-xLogIN-8c and for function slots ABT-xLogIN-8f ABT-xLogIN-8c ABT-xLogIN-8f The logical
More informationPUSH BUTTON PANEL. SECTION 3A (Rev. B) SECTION CONTENTS. Download from Technical Manuals area. sec.3a
SECTION 3A (Rev. B) Download from www.urmet.com Technical Manuals area. SINTHESI 2 CAMERA MODULE AND DOOR UNIT WITH 2 BUTTONS...2 Features...2 Structure...2 Terminals pins description...3 Technical characteristics...3
More informationLeased Line. NIONs. NCB Routers. Typical Application of NCB Routers
NCB/IM Router Product Installation Document This document covers the procedures and specifications for installing the above listed unit and when appropriate, information regarding configuration on the
More informationCONTROL MICROSYSTEMS and 5404 Digital Input Module. Hardware Manual
503 and 50 Digital Input Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support: -6-676
More informationAllen-Bradley Drives
Installation Data This document provides information on: important pre installation considerations power supply requirements installing the module installing and connecting the wiring using the module
More informationTXM1.8RB. TX-I/O Blinds module
s 8 178 8178p01 TX-I/O Blinds module TXM1.8RB 8 non-floating relay outputs for... 4 blinds motors with 2 end switches, or 2 blinds motors with 3 end switches, or 2 blinds motors with 2 end switches + 1
More informationCHASSIS INSTALLATION GUIDE
SUPER SC942S-600 SC942i-600/550 SC942 CHASSIS INSTALLATION GUIDE 1.0 SUPER SC942 Chassis User's Guide Table of Contents Chapter I: Unpacking and Check Lists... 1-3 Chapter 2: Installation Procedures...
More informationMicro USB Lamp Kit ESSENTIAL INFORMATION. Version 2.0 DESIGN A STYLISH LAMP WITH THIS
ESSENTIAL INFORMATION BUILD INSTRUCTIONS CHECKING YOUR PCB & FAULT-FINDING MECHANICAL DETAILS HOW THE KIT WORKS DESIGN A STYLISH LAMP WITH THIS Micro USB Lamp Kit Version 2.0 Build Instructions Before
More informationAUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL
AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL 2 INTRODUCTION First and foremost we would like to thank you for purchasing this product. Our commitment to satisfying our customers can be seen
More informationComplete Installation manual
VapoChill TM CPU Cooling System - LightSpeed [AC] TM asetek Inc. Complete Installation manual Date Version Comments 01-04-2004 1.0 1 Installing the VapoChill LightSpeed [AC] TM Preparing the case Step
More informationTXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O
s 8 179 8179p01 TX-I/O Triac module sed for Thermic and motor-driven actuators (AC 24 V) AC 24 V-controlled devices TXM1.8T 8 triac outputs (AC 24 V), configured individually for: Permanent contact Three-point
More informationThe PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.
PM1000 SERIES PLUG-ON DISPLAY BRIGHT LED DISPLAY INDICATION RANGE -999 TO +9999 FITS TO DIN 43650 CONNECTOR PLUG-ON TO ANY TRANSMITTER WITH 4-20MA OUTPUT EASY TO SCALE ON SITE ROBUST DESIGN SET POINT OPTION
More informationJUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet
sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous
More informationPeak/Valley Hold Unit (PVHU) User Manual V3.00
Peak/Valley Hold Unit (PVHU) User Manual V3.00 Part Number: DO-UM0084/30/UE Applies to Firmware Version: V3.01 Reference: Peak_Valley Hold Unit (PVHU) User Manual.docx Date: 30 May 2016 Version: 3.00 Peak/Valley
More informationThe basic product comes with the IRS5 control board, 3 internal cables, 1 external cable with a 5 volt adapter and a mounting bracket with hardware.
Please read these instructions and watch the Installation Video before you proceed with the installation of the PC-IRS5-01. Installation Video: http://youtu.be/os98e32vhb4 The PC-IRS5-01 Infrared Receiver
More informationInstallation Manual CCL 20 D PTZ camera controller unit DIN-rail mounting
Installation Manual PTZ camera controller unit DIN-rail mounting CIB-tech I n t r o d u c t i o n The is a PTZ (Pan Tilt Zoom) video camera control unit, part of the CIB-tech automation system. The can
More informationLVX Control Unit. Features:
Date 2013-02-28 Control Unit Features: Most parameters can be defined as required for your interfaces. You decide which information is output and how. Fast cycle times, just a few µs/beam. Maximum beam-count
More informationSTEP MOTOR DRIVER SMD-4.2DIN
SMART MOTOR DEVICES http://www.smd.ee STEP MOTOR DRIVER SMD-4.2DIN manual SMDDIN.42.001 2018 1. Product designation Step motor controller SMD-4.2DIN is an electronic device designed to operate with 2 or
More informationInstallation Instructions
Installation Instructions This document provides information on: important pre-installation considerations power supply requirements initial handling installing the module using the indicators for troubleshooting
More informationInspiron 22. Service Manual Series. Regulatory Model: W17B Regulatory Type: W17B001
Inspiron 22 3000 Series Service Manual Regulatory Model: W17B Regulatory Type: W17B001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your
More informationPSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B
PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B Safety Relay for Emergency Stop and Safety Door Circuits INTERFACE Data Sheet 102858_02_en PHOENIX CONTACT - 12/2006 Description The PSR-...- 24DC/SDC4/2X1/B
More informationVXI-SC-1000 CARRIER MODULE
VXI-SC-000 CARRIER MODULE Introduction This guide describes how to assemble, configure, and install the VXI-SC-000 carrier module with any of the VXI-SC submodules. The VXI-SC-000 carrier module provides
More informationDIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL
DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL REVISED: 8/12/13 DGH CORPORATION PO BOX 5638 MANCHESTER, NH 03108 TELEPHONE: 603-622-0452 FAX: 603-622-0487 WEB: www.dghcorp.com The information
More informationPOSITION MONITOR USERS MANUAL POM-M2 / POM-M3. Content
POM-M2 POM-M3 POSITION MONITOR USERS MANUAL Content 1 TECHNICAL SPECIFICATION... 2 2 DESCRIPTION... 2 3 HANDLING... 3 3.1 Calibration... 3 3.2 Limit setting... 3 4 CONNECTION... 4 4.1 K1 Power supply...
More informationAssembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN
Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN Please enter the identity code of your device here! DXMa _ Please carefully read these operating instructions
More informationPCB AS-i modules, board based solutions
Special variants on request (Figure similar) PCB modules, board based solutions Circuit Inputs board dimensions digital Inputs analog Outputs digital Connection Coated LED status display 4 Input voltage
More informationFront-door station series for surface-mounting Profi-Economic PES Profi-Design PDS
Product information Front-door station series for surface-mounting Profi-Economic PES Profi-Design PDS PI_GB_PES_PDS_Art0015689_1v0.doc 2 10/2005 In Table of contents Scope of delivery...3 Safety notices...3
More informationAir gap sensors SOPA
Product range overview Key features General Lightweight, compact and highly precise, this pneumatic solution offers impressive scope for integration: SOPA features a control module, compressed air regulation,
More informationAccessories and options
Novigo Accessories and options PCA2001-A1, PCA2002-A1, PCA2004-A1, PCA2005-A1, PCA2007-A1, PCA2008-A1, PCA2011-A1, PCA2012-A1, PCA2013-A1, PCIO2001-A1, PCO2001-A1, PNA2007-A1 Accessories and optional components
More informationAS-Interface I/O Module
AS-Interface I/O Module Construction The AS-Interface I/O module is designed as a compact, robust field module. It is composed of an electronic module (top) and a coupler module (base). Connectors (standard
More informationUltraloq UL3 Series Fingerprint and Touchscreen Smart Lock
Ultraloq UL3 Series Fingerprint and Touchscreen Smart Lock Installation Instructions ( V1.4 ) Welcome Installation Video Please watch our easy step by step installation video before attempting to install
More informationIPCSDTouch-G 1/5. GLOBALCOM.IP Touch Screen Digital Communication Station. IPCSDTouch-H (Handheld Microphone Version) Features. General Description
1/5 IPCSDTouch-H & -G GLOBALCOM.IP Touch Screen Digital Communication Station Features Fully programmable touch screen user interface Supervision of the microphone element Handheld, Gooseneck, Surface