PCB AS-i modules, board based solutions

Size: px
Start display at page:

Download "PCB AS-i modules, board based solutions"

Transcription

1 Special variants on request (Figure similar) PCB modules, board based solutions Circuit Inputs board dimensions digital Inputs analog Outputs digital Connection Coated LED status display 4 Input voltage (sensor supply 5 Output voltage (actuator supply) 6 address Art. no. wiring pins no no out of out of BW566 no no out of out of BW8 9,x6,5 no no out of out of BW44 no no out of out of BW9 (input is morror ed) only to pins no (varnish ed) no out of out of BW95 solder lugs no no out of out of BW4 4 no no out of out of BW8 x,5 4 plug-in spring-type no no out of out of BW9 4 wiring pins no no out of out of BW86 4 solder lugs no no out of out of BW408 4 solder lugs no yes out of out of AUX BW68 We reserve the right to change any data Mannheim,.5. page

2 PCB modules, board based solutions Circuit board dimensions Inputs digital Inputs analog Outputs Connection Coated digital LED status display 4 Input voltage (sensor supply 5 Output voltage (actuator supply) 6 address Art. no. no no out of out of BW9 no no out of AUX out of AUX BW89 no yes out of out of BW40 no (varnish ed) yes out of out of BW89 no yes out of out of AUX BW68 yes yes out of out of AUX BW80 plug-in spring-type no no out of out of BW889 x,5 connecting wires yes yes out of out of BW59 connecting wires yes yes out of out of BW5 wiring pins no no out of out of wiring pins no yes out of out of AUX solder lugs no yes out of out of solder lugs no no out of out of solder lugs no yes out of out of AUX BW8 BW59 BW468 BW05 BW44 8 no no out of AB s BW5 8 connecting wires yes no out of AB s BW4 8 wiring pins no no out of AB s BW5 6 no no out of AB s BW6 x 0 wiring pins no yes out of out of BW05 page Mannheim,.5. We reserve the right to change any data

3 circuit board dimensions: holes for assembly angles. connection: further connection options are available on request. nominal cross section 0,5 mm wiring pins contact spacing,54 mm solder lugs contact spacing,54 mm plug-in spring type nominal cross section 0,5 mm connecting wires cross section 0,4 mm Coated: coating protects components and circuit boards when touched. not coated coated 4 LED status display: status of in- and outputs is indicated by LEDs. In addition to that, both LEDs (PWR green and FAULT red) show -as usual regarding the s- the status of the s. Uaux is indicated by a green LED. 5 Input voltage (sensor supply): inputs are supplied by or by AUX (auxiliary 4V power). If supplied by, inputs can neither be connected to earth nor to external potential. 6 Output voltage (actuator supply): outputs are supplied by or by AUX (auxiliary 4V power). If supplied by, inputs can neither be connected to earth nor to external potential. address: AB (max. 6 AB s/ network), AB s (max. modules with AB s), Single s (max. Single s/per network), mixed use allowed. We reserve the right to change any data Mannheim,.5. page

4 Technical data for further articles, see the next page! Article no. BW566 BW8 BW44 BW9 BW95 BW4 Connection /peripheral connection wiring pins only to pins Length of connector cable,5 m Profile, S-IO.ID.ID S-B.A.E, S-.A. ID = (default) ID=E (default) Address Operating voltage (8...,6V) Required Master profile M Since specification. Max. current consumption 0mA 0mA Inputs digital Number Power supply out of Power supply of attached sensors max. 80mA, 80mA S-B.A.E, ID = (default) solder lugs Input level U in < V low, U in > high Outputs digital Number Power supply out of Max. current consumption 80mA per output, 80mA Display LED indicators no Environment Applied standards EN EN Operating temperature -5 C 0 C Storage temperature -40 C 85 C Allowed shock and vibration acceleration 5g, T ms, 0..55Hz, 0,5mm amplitude stress Coating no no, varnished no Protection class acc. to DIN EN IP Dimensions (W / H / D) 9, x 6,5 x 0 mm page 4 Mannheim,.5. We reserve the right to change any data

5 Article no. BW8 BW9 BW86 BW408 BW68 Connection /peripheral connection plug-in spring-type wiring pins solder lugs Length of connector cable,5 m Profile, S-IO.ID.ID S-.A.E, ID = (default) Address Operating voltage (8...,6V) Required Master profile M Since specification. Max. current consumption 0mA 0mA AUX Voltage 4V (8 ) Max. current consumption,a Inputs digital Number 4 Power supply out of Power supply of attached max. 80mA, max. 80mA sensors 80mA Input level U in < V low, U in > high Outputs digital Number Power supply out of out of AUX Max. current consumption 00mA per output, 80mA 50mA per output, Σ 500mA Display LED indicators no yes Environment Applied standards EN EN Operating temperature -5 C 0 C Storage temperature -40 C 85 C Allowed shock and vibration acceleration 5g, T ms, 0 55Hz, 0,5mm amplitude stress Coating no Protection class acc. to DIN EN 6059 IP00 Dimensions (W / H / D) x,5 x mm x,5 x mm x,5 x 0 mm x,5 x mm x,5 x 0 mm We reserve the right to change any data Mannheim,.5. page 5

6 Article no. BW9 BW89 BW40 BW89 BW68 BW80 BW889 Connection /peripheral connection plug-in spring-type Length of connector cable,5 m Profile, S-IO.ID.ID S-.0.F, S -.A., ID= (fix) ID=F (default) Address Operating voltage (8...,6V) Required Master profile M0 M4 Since specification.0.0 Max. current consumption 00mA 40mA 0mA 60mA 0mA AUX Voltage 4V 4V (8 ) (8 ) Max. current consumption,a,a Inputs digital Number 4 Power supply out of out of AUX out of Power supply of attached sensors max. 60mA, 60mA max. 80mA, 80mA max. 60mA, 60mA no power supply max. 80mA, 80mA Input level U in < V low, U in > high Outputs digital Number 4 Power supply out of out of AUX out of out of AUX out of Max. current consumption 00mA per outputs, 60mA 00mA per outputs, 80mA 00mA per output, 60mA 50mA per outputs, Σ 500mA 00mA per outputs, 80mA Display LED indicators no yes no Environment Applied standards EN EN Operating temperature -5 C 0 C Storage temperature -40 C 85 C Allowed shock and vibration stress acceleration 5g, T ms, 0 55Hz, 0,5mm amplitude Coating no no, varnished no yes no Protection class acc. to DIN IP00 EN 6059 Dimensions (W / H / D) x,5 x 0 mm x,5 x mm x,5 x 0 mm page 6 Mannheim,.5. We reserve the right to change any data

7 Article no. BW59 BW5 BW8 BW59 BW468 BW05 BW44 Connection /peripheral connection Length of connector cable Profile, S-IO.ID.ID connecting wires wiring pins solder lugs S-.0.F, ID =F (default) S -.A., ID= (fix) S-.0.F, ID =F (default),5 m S-.0.E, ID=F (default) S-.0.F, ID =F (default) S -.A., ID= (fix) Address Operating voltage M0 M4 M0 M4 Required Master profile Since specification 8...,6V Max. current 0mA 0mA 00mA 0mA 00mA 0mA consumption AUX Voltage 4V 4V (8 ) (8 ) Max. current,a,a consumption Inputs digital Number 4 Power supply out of Power supply of attached sensors max. 60mA, 60mA max. 80mA, 80mA max. 60mA, 60mA max. 60mA max. 60mA, 60mA max. 80mA Input level U in < V low, U in > high Outputs digital Number 4 Power supply out of out of AUX out of out of AUX Max. current consumption 00mA per output, 60mA 00mA per output, 80mA 00mA per output, 60mA 50mA per output, Σ 500mA 00mA per output, 60mA 50 ma per output in total 500 ma Display LED indicators yes no yes no yes Environment Applied standards EN EN Operating temperature -5 C 0 C Storage temperature -40 C 85 C Allowed shock and vibration acceleration 5g, T ms, 0 55Hz, 0,5mm amplitude stress Coating yes no Protection class acc. to DIN EN 6059 IP54 IP00 Dimensions (W / H / D) x,5 x mm x,5 x mm x,5 x 0 mm x,5 x mm x,5 x 0 mm We reserve the right to change any data Mannheim,.5. page

8 Article no. BW5 BW4 BW5 BW6 BW05 Connection /peripheral connection connecting wires wiring pinswiring wiring pins pins Length of connector cable,5 m Profile, S-IO.ID.ID x S-0.A., ID= (default) x S-8.A.0, D= (default) S-..D, ID=F (default) Address AB s Operating voltage M Required Master profile. Since specification 8...,6V Max. current consumption 0mA 0mA Inputs digital Number 8 Power supply out of Power supply of attached max. 80mA max. 5mA sensors Input level U in < V low, U in > high Outputs digital Number 6 Power supply out of Max. current consumption 00mA per outputs, Σ 80mA Inputs analog Number Power supply out of Input level 0... Internal resistance 00kΩ Display LED indicators no Environment Applied standards EN EN Operating temperature -5 C 0 C Storage temperature -40 C 85 C Allowed shock and vibration acceleration 5g, T ms, 0 55Hz, 0,5mm amplitude stress Coating no yes no Protection class acc. to DIN EN 6059 IP00 IP54 IP00 Dimensions (W / H / D) x,5 x 0 mm x,5 x mm x,5 x 0 mm page 8 Mannheim,.5. We reserve the right to change any data

9 Programming Bit setting Digital IO D0 D D D D0 D D D BW4, BW44, BW8, I I BW8, BW86, BW408, BW9, BW8, BW9, BW889, BW89, BW40, BW89, BW68, BW5, BW59, BW468, BW05, BW68, BW59, BW44, BW80 I I I I4 BW5, BW5, BW4 I I I I4 I5 I6 I I8 BW6 BW9 I I I I Output BW4, BW44, BW8 O O BW8, BW86, BW408, BW9, BW8, BW9, BW889, BW89, BW40, BW89, BW68, BW5, BW59, BW468, BW05, BW68, BW59, BW44, BW80 O O O O4 BW5, BW5, BW4 BW6 O O O O4 O5 O6 BW9 O O Parameter bit P0 P P P BW4, BW44, BW8 not used BW8, BW86, BW408, BW9, BW8, BW9, BW889, BW89, BW40, BW89, BW68, BW5, not used BW59, BW468, BW05, BW68, BW59, BW44, BW80 BW5, BW5, BW4 not used BW6 not used BW05 Programming BW4, BW44, BW8, BW8, BW86, BW408, BW9, BW8, BW9, BW889, BW89, BW40, BW89, BW68, BW5, BW59, BW05, BW9, BW80 BW5, BW5, BW4 BW6 Dip switch settings BW5, BW5, BW4, BW6 : peripheral fault is indicated 0: peripheral fault is not indicated : dec. 0: dec. (Siemens format) Input : regular 0: fast Address preset 0 changeable via bus master or programming devices Address preset 0 0 changeable only via Master in configuration mode. Address preset 0 changeable only via Master in configuration mode. ON:. is deactivated OFF:. activated : channel on 0: channel off We reserve the right to change any data Mannheim,.5. page 9

10 Connections:, - Connection to the bus E - E4 (I - I4) Inputs A - A4 (O - O4) Outputs Reference potential for outputs oder 4V Output for 4V power supply for the inputs 4V_in Input for 4V power supply 4V_, 4_4 Output for 4V power supply for inputs and/or 4 Sig, Sig Positive terminal of analog inputs Sig-, Sig- Negative terminal of analog inputs nc (not connected) not connected Dimensional drawings BW4, BW44, BW8, BW566, BW95, BW9 6,5 BW8, BW9, BW86, 408, BW8, BW9, BW89, BW40, BW468, BW5, BW59, BW68, BW80, BW5, BW4, BW5, BW6, BW89, BW889, BW05, BW68, BW05, BW44, BW59 9,,6 r,5 d,6,54 5,5 r d, 9,9,54 66 x8,5,5 LED assignment BW68, BW40, BW89, BW68, BW80, BW59, BW5, BW59, BW468, BW44, O4 O O O FAULT I4 I I I page 0 Mannheim,.5. We reserve the right to change any data

11 Terminal diagram BW4, BW44, BW8 BW8, BW9, BW86, BW408, BW8, BW9, BW40, BW468, BW89, BW889, BW05, BW5, BW E A E A nc nc ASI BW89 BW5, BW4, BW V_ E A E A E A E4 A4 4V_4 4V_in ASI Pwr IN IO-Block IO-Block 4 Pwr ASI IN nc E E 0 E E4 E5 E6 0 E E8 0 nc ASI BW6 BW68, BW _in 4V E A E A E A E4 A4 4V 4V_in ASI Pwr IN IO-Block IO-Block 4 Pwr ASI IN BW05 BW Sig Sig - 4V Sig Sig - nc ASI We reserve the right to change any data Mannheim,.5. page

12 BW68 BW44, BW _ext_in _ASI E A _ext_out E A _ext_out E A _ext_out E4 nc _ext_out U_ASI 4V ext_in ASI _ext_in _ASI E A _ext_out E A _ext_out E A _ext_out E4 A4 _ext_out U_ASI 4V ext_in ASI PWR IN -PWR OUT PWR PWR OUT IN PWR IN -PWR OUT PWR PWR OUT IN page Mannheim,.5. We reserve the right to change any data

Analog Modules AS-i, IP67, M12

Analog Modules AS-i, IP67, M12 Analog Modules, M12 2 x 2 connectors for compact housing, IP67 (Figure similar) Figure Type Inputs analog Outputs analog M12 connection Input voltage (sensor supply) Output voltage (actuator supply) (2)

More information

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports / IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master single in one housing Power supply of s out of AUX (or ) Figure Type Inputs digital 8x M 8x M 4 x + 4 x + Outputs digital

More information

Digital Modules AS-i, IP67, M12

Digital Modules AS-i, IP67, M12 Digital Modules, IP67, M1 x connectors for color LEDs per output, state (yellow), overload (red) BWU487 / BWU547 / BWU55 / BWU594 / BWU60 / BWU713 / BWU75 / BWU78 (Figure similar) BWU617 / BWU619 / BWU66

More information

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports / IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master in one housing Power supply of s (or ) (Figure similar) Figure Type Inputs digital 4 x + 4 x + 4 x Outputs digital M12

More information

Analog Modules AS-i IP65, M12

Analog Modules AS-i IP65, M12 Plug and Play as simply as digital AS-i I/O BWU1361 / BWU1362 / BWU1722 / BWU1853 / BWU1917 / BWU1363 / BWU2532 / BWU1359 / BW1360 / BWU1893 BWU1894 BWU1895 BWU1963 BWU1964 Housing, construction: IP65,

More information

Digital Modules AS-i in IP20, 22,5 mm

Digital Modules AS-i in IP20, 22,5 mm Digital Modules AS-i in 22,5 mm Cost efficient solution in IP20 (Figure similar) Figure Type Housing s digital digital voltage (sensor supply) (1) Output voltage (actuator supply) (2) AS-i connection (3)

More information

AS-i Safety Analog Input Module, IP20

AS-i Safety Analog Input Module, IP20 2 safe inputs in one module: 4... 20 ma or 0... 10 V or Pt100 or thermocouple (type J / K / N / R / S) Applications up to category 4/PLe/SIL 3 (figure similar) The AS-i Safety Input Module for analog inputs

More information

AS-i Safety Input Modules (M12), IP67

AS-i Safety Input Modules (M12), IP67 Input Modules (), IP67 Input Modules (), IP67 for opto, floating contacts or complementary switch Applications up to category 4/PLe/SIL 3 (Figure similar) Figure Type Inputs, SIL 3, cat. 4 4 x, 4 x, 4

More information

Active Distributors AS-i Safety, Active Distributors AS-i

Active Distributors AS-i Safety, Active Distributors AS-i Active Distributors Safety, Active Distributors x connectors for Periphery connection via, M cable sockets or push in terminals (Figure similar) Figure Type Inputs Safety, SIL, Cat. x 9 mm, -channels Safety

More information

Encoder signal/ Sensor signal. Number of monitored axes. sine/cosine, SSI, TTL (1) up to 2 independent axes. sine/cosine. up to 2 independent axes

Encoder signal/ Sensor signal. Number of monitored axes. sine/cosine, SSI, TTL (1) up to 2 independent axes. sine/cosine. up to 2 independent axes w AS-i Speed Monitor for sine/cosine encoder for HTL encoder for SSI encoder for TTL encoder for sensors for 2 fast electronic safe outputs 128 devices Supplied out of AS-i and external 24 V (figure similar)

More information

AS-i Safety Output Module, IP20

AS-i Safety Output Module, IP20 a AS-i Safety Output Module Safe outputs and standard inputs in one module Protection category IP20 Figure Housing Inputs digital Outputs Safety, SIL3, cat.4 Input voltage (sensor supply) 1 Output voltage

More information

AS-i 3.0 Motor modules

AS-i 3.0 Motor modules AS-i 3.0 motor modules for two 4 V motorized rollers e.g. Interroll (EC00, EC300, EC310) or RULMECA (RDR BL-) or Itoh Denki (PM00ME/XE/XP, PM60ME/XE/XP) slaves in one module 1 Single Slave with - s - digital

More information

AS-i Safety Output Module with Diagnostic Slave, 1 EDM input, 3I and 2O

AS-i Safety Output Module with Diagnostic Slave, 1 EDM input, 3I and 2O ext. in ext. in Safety Output Module with Safety and standard I/O in one module Electronic safety output Additional 3 standard inputs, 1 EDM input, 2 outputs IEC 61508 SIL 3, EN ISO 13849-1 PLe Cat 4,

More information

AS-i 3.0 motor module

AS-i 3.0 motor module 3.0 motor module 3.0 motor module for two 4 V motorized rollers Itoh Denki (PM00ME/XE/XP, PM60ME/XE/XP) with 4 binary and analog outputs Mixed input/output slave Speed setting of parameter Protection category

More information

Active Distributors ASi Safety, IP67

Active Distributors ASi Safety, IP67 x connectors for profile cable Periphery connection via M8 cable sockets M cable sockets (Figure similar) Figure Type Inputs, SIL 3, Cat. 4 9 mm 9 mm 9 mm 9 mm channels channels channels channels Inputs

More information

AS-i 3.0 motor modules

AS-i 3.0 motor modules AS-i 3.0 4I/4O modules for two 4 V motorized rollers e.g. Interroll (EC00, EC300 or EC30) or RULMECA (RDR BL-) or Rollex (type 840) with binary and analog outputs Mixed input/output slave Speed setting

More information

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category IP20

More information

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input ext. in ext. in AS-i Safety Relay Output Module with Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V Additionally 1 EDM input, 1 x

More information

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor AS-i 3.0 Gateways 2 AS-i Masters, 1 PROFIBUS Slave Up to 32 release circuits up to 6 CAT4, SIL 3 safe output circuits on the Monitor safe relays or fast electronic safe outputs up to 32 independent AS-i

More information

AS-i 3.0 Sercos Gateways with integrated Safety Monitor

AS-i 3.0 Sercos Gateways with integrated Safety Monitor AS-i 3.0 Sercos Gateways with Safety on Sercos and Safe Link in one device up to 456 Devices Safely monitoring safety drives with Safety on Sercos 2 / 1 AS-i master, Sercos slave switch integrated (figure

More information

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor AS-i 3.0 -Gateways 2 / 1 AS-i Master, -Slave (1) switch integrated Up to 64 release circuits up to circuits SIL 3, cat. 4 on the Monitor, relays or fast Safe AS-i outputs are supported up to 32 independent

More information

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor AS-i 3.0 Gateways 2 / 1 AS-i Master, Slave 1 AS-i Safety Monitor for 2 s Operation using a single Monitor! Monitor processes safety slaves on two s Coupling between the two networks superfluous Up to 32

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves

More information

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor AS-i 3.0 Gateways AS-i 3.0 Gateways 2 / 1 AS-i Master, Slave 1 AS-i Safety Monitor for 2 AS-i networks Operation using a single Monitor configuration! Monitor processes safety slaves on two AS-i networks

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves switch via safe Up to 32 release circuits up

More information

AS-i 3.0 PROFINET-Gateways with integrated Safety Monitor

AS-i 3.0 PROFINET-Gateways with integrated Safety Monitor AS-i 3.0 PROFI Gateways with Master, 1 PROFI Slave Up to 32 release circuits up to 6 safe output circuits on the Monitor safe relays or fast electronic safe outputs up to 32 independent AS-i outputs Multiple

More information

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC Safety + standard I/O in one module AS-i Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category

More information

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor AS-i 3.0 -Gateways 2 / 1 AS-i Master, -Slave 1 switch integrated up to 32 release circuits up to 6 release circuits SIL 3, cat. 4 on the Monitor Safe AS-i outputs are supported up to 32 independent AS-i

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via or AS-i 3.0 Gateways, safe via or 2 / 1 Master, / Slave AS-i Safety input slaves report via safe AS-i Safety output slaves switch via safe Up to 32 release circuits up to 6 CAT4, SIL 3 safe output

More information

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor AS-i 3.0 Gateways AS-i 3.0 Gateways 2 / 1 AS-i Master, Slave 1 AS-i Safety Monitor for 2 s Operation using a single Monitor! Monitor processes safety slaves on two s Coupling between the two networks superfluous

More information

AS-i 3.0 EtherCAT Gateways with integrated Safety Monitor

AS-i 3.0 EtherCAT Gateways with integrated Safety Monitor AS-i 3.0 EtherCAT Gateways with 2 / 1 Master, EtherCat Slave 1 Safety Monitor for 2 s Operation using a single Monitor! Monitor processes safety slaves on two s Coupling between the two networks superfluous

More information

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor AS-i 3.0 Gateways AS-i 3.0 Gateways 2 / 1 Master, Slave 1 AS-i Safety Monitor for 2 AS-i networks Operation using a single Monitor configuration! Monitor processes safety slaves on two AS-i networks Coupling

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET via PROFI or PROF AS-i 3.0 Gateways, via PROF or PROFI 22 / 1 Master, PROF / PROFI Slave AS-i Safety input slaves report via AS-i Safety output slaves switch via Up to 32 release circuits up to 6 CAT4,

More information

Installation Instructions Temperature transmitter TAA /00 06/2011

Installation Instructions Temperature transmitter TAA /00 06/2011 Installation Instructions Temperature transmitter TAA431 706042/00 06/2011 Contents 1 Functions and features...3 2 Installation...4 2.1 Addressing...4 2.2 Mechanical installation...4 2.3 Connection to

More information

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features: DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S:

More information

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I Characteristics counter kit STB - 1 CH - 0..40000 Hz - 2 I Main Range of product Product or component type Number of channels 1 Complementary Kit composition Counting input number 2 Counting frequency

More information

Diagnostics (Logical)

Diagnostics (Logical) Input Station Rugged, Fully Potted Stations IP 67 Protection Flat and Round Cable Support AS-I Version 2.1 FAS4-S0400 Electrical Operating Current:

More information

Operating instructions. ProcessLine analogue module AC / / 2012

Operating instructions. ProcessLine analogue module AC / / 2012 Operating instructions ProcessLine analogue module AC2916 739089 / 01 06 / 2012 Contents 1 Safety instructions... 3 2 Functions and features... 4 3 Operating and display elements... 4 4 Electrical connection...

More information

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3. Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and

More information

AS-Interface I/O Module

AS-Interface I/O Module AS-Interface I/O Module Construction The AS-Interface I/O module is designed as a compact, robust field module. It is composed of an electronic module (top) and a coupler module (base). Connectors (standard

More information

Diagnostics (Logical) Diagnostics (Physical)

Diagnostics (Logical) Diagnostics (Physical) Analog Output Stations Analog on AS-I IP 20 for In-The-Cabinet Powered by AS-I or Auxiliary Supply Voltage and Current Outputs ASI-AO-2 BW1412 ASI-AO-2A BW1727 Electrical Operating Current:

More information

Sensor boxes SRBG Key features

Sensor boxes SRBG Key features Key features Function SRBG sensor boxes are the compact solution when it comes to electrical feedback signals and monitoring the position of process valves which are actuated with pneumatic quarter turn

More information

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D D600S - D600D INSTRUCTI MANUAL SIL Switch/Proximity Detector Repeater Relay, DIN Rail, Models D600S, D600D D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0- Characteristics General

More information

Online data sheet RE13-SAC RE1 NON-CONTACT SAFETY SWITCHES

Online data sheet RE13-SAC RE1 NON-CONTACT SAFETY SWITCHES Online data sheet RE13-SAC RE1 A B C D E F H I J K L M N O P Q R S T Detailed technical data Features System part Sensor principle Ordering information Other models and accessories Number of N/O contacts

More information

Making Hazardous Operations Safe and Productive

Making Hazardous Operations Safe and Productive NEW Safety Guard Switching Unit G9SX-GS Making Hazardous Operations Safe and Productive Making Hazardous Operations Safe and Productive This new addition to the model of Flexible Safety Unit G9SX series

More information

XUK8TAKSMM12 photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN

XUK8TAKSMM12 photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN Characteristics photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN Complementary Enclosure material Lens material Maximum sensing distance Output type Add on input Wire insulation material Status

More information

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 1 Series 9475/ www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

Inclinometer. 4-20mA and RS232

Inclinometer. 4-20mA and RS232 Inclinometer 4-20mA and RS232 Real size Main Features - Two axis digital inclinometer n - Angle measurement range of +/-5, +/-15 and +/-30, Resolution up to 0.001 - Active linearization and temperaturecompensation

More information

MBM - Modular I/O system IP20

MBM - Modular I/O system IP20 - Modular I/O system IP20 Input/output module digital 4-way Ordering data 4 digital inputs and outputs 55882 3-wire screw terminal block 55832 3-wire spring clamp terminal block 55852 Load weight 1) 1.00

More information

BMXEHC0200 high speed counter module M340-2 channels

BMXEHC0200 high speed counter module M340-2 channels Product data sheet Characteristics BMXEHC0200 high speed counter module M340-2 channels Complementary Counter functions Cycle time Isolation voltage Input type Input voltage limits Input current Voltage

More information

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB Strain gauge Measuring Amplifier GSV-1A8 Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB GSV-1A8USB SubD1 (front side) GSV-1A8USB M12 (front side) GSV-1A16USB (rear side) GSV-1A8USB K6D (front side)

More information

TABLE OF CONTENTS AS-INTERFACE

TABLE OF CONTENTS AS-INTERFACE TABLE OF CONTENTS AS-Interface module AAAA...2 AS-Interface module EEAA...4 AS-Interface module EEEE...6 AS-Interface coupler module PGK...8 AS-Interface coupler module FKK...10 AS-Interface coupler module

More information

Cube20. Application-oriented. Installation-friendly. Efficient

Cube20. Application-oriented. Installation-friendly. Efficient Cube20 Application-oriented Installation-friendly Efficient 02 Cube20 Universal and flexible combined with Cube67 03 CUBE20 FIELDBUS I/Os FOR CONTROL CABINETS Application: Control cabinets Plant construction

More information

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB Strain gauge Measuring Amplifier GSV-A8 Instruction manual GSV-A8, GSV-A8USB, GSV-A6USB GSV-A8USB SubD5 (front side) GSV-A8USB M2 (front side) GSV-A6USB (rear side) GSV-A8USB K6D (front side) Version:

More information

Inclination sensors 2-dimensional, measuring range up to ±90

Inclination sensors 2-dimensional, measuring range up to ±90 Features Size 52 mm MEMS capacitive measuring principle EN13849 compliant firmware E1 compliant design Interface CANopen, SAE J1939, Analog Connection M12 and cable Protection up to IP 69K Optional GIM500R

More information

Connectors DIN 41612/IEC

Connectors DIN 41612/IEC Connectors DIN 41612/IEC 60603-2 and completions General information The DIN 41612/IEC 60603-2 connector family consists of 13 basic sizes and many complementary versions. It was developed for use in 19"

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D D603S D603D INSTRUCTI MANUAL SIL 3 Switch/Proximity Detector Repeater Relay, Termination Board Models D603S, D603D D603 SIL 3 Switch/Proximity Detector Repeater Relay G.M. International ISM0400 General

More information

Online data sheet STR1-SASM03P5 STR1 NON-CONTACT SAFETY SWITCHES

Online data sheet STR1-SASM03P5 STR1 NON-CONTACT SAFETY SWITCHES Online data sheet STR1-SASM03P5 STR1 A B C D E F H I J K M N O P Q R S T Detailed technical data Features System part Sensor principle Ordering information Other models and accessories Number of safe outputs

More information

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function Safety Guard Switching Unit CSM DS_E_6_1 A Safety Measure for Hazardous Operations That Does Not Lower Productivity Two functions support two types of application: Auto switching: For applications where

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

Internal Buffer/Boiler Module HZS 534

Internal Buffer/Boiler Module HZS 534 INTERNAL BUFFER/BOILER MODULE HZS 534 Internal Buffer/Boiler Module HZS 534 30.11.2015 Page 1 INTERNAL BUFFER-/BOILERMODUL HZS 534 Configuration HZS 534 internal buffer/boiler module for the heating controller

More information

Expansion Module HZS 541-1S

Expansion Module HZS 541-1S Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs

More information

SIMOCODE 3UF Motor Management and Control Devices

SIMOCODE 3UF Motor Management and Control Devices Technical specifications General data applicable to the basic units, current measuring modules, current/voltage measuring modules, expansion modules, decoupling module and operator panel Permissible ambient

More information

Safety controller unit B1 /

Safety controller unit B1 / Version 1.0 Safety controller unit 470111B1 / For 2 to 16 safety sensors 470115B1 PL d in acc. with EN ISO 13849-1 / SIL CL 2 in acc. with EN IEC 62061 Two safety outputs and external contactor monitoring

More information

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities. Switching Power Supplies The offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities. With U 508 isting, additional savings in space and cost can be realized

More information

LED Dimmer LED-08T

LED Dimmer LED-08T Dimmer -08T General The dimmer was especially developed to control s in ground plan touch pads. For the fi rst time this device enables you to control the brightness of s between 0 and 100% so that it

More information

Monitor. Safety relay,etc. Contactor, etc. Uses external device monitoring function Note: Construct a separate reset input circuit.

Monitor. Safety relay,etc. Contactor, etc. Uses external device monitoring function Note: Construct a separate reset input circuit. Selectable safety circuits The light curtain unit has a built-in monitoring function for external devices (such as fused relay monitoring). This supports the construction of light curtain peripheral safety

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

Time Counters mini "h", DC Version

Time Counters mini h, DC Version Type 633-DC Time Counters mini "h", DC Version Type 633.0 Type 633.7 Type 633.8 High shock resistance Miniature dimensions Electrical connections in standard grid Suitable for PCB mounting Machine-solderable

More information

Online data sheet STR1-SAFM03P5 STR1 NON-CONTACT SAFETY SWITCHES

Online data sheet STR1-SAFM03P5 STR1 NON-CONTACT SAFETY SWITCHES Online data sheet STR1-SAFM03P5 STR1 A B C D E F H I J K M N O P Q R S T Detailed technical data Features System part Sensor principle Ordering information Other models and accessories Number of safe outputs

More information

Protected VARAN Digital Mixed Module PVDM 086

Protected VARAN Digital Mixed Module PVDM 086 PROTECTED VARAN DIGITAL MXED MODULE PVDM 086 Protected VARAN Digital Mixed Module PVDM 086 The PVDM 086 Protected VARAN Digital Mixed Module has eight +24 V/2 A digital outputs (positive switching) that

More information

Technical Data. C-DIAS-MULTI l/o MODULE CIO 013

Technical Data. C-DIAS-MULTI l/o MODULE CIO 013 C-DIAS-MULTI l/o MODULE CIO 013 C-DIAS-Multi I/O Module CIO 013 6 x digital inputs (+24V, 5mA, 5ms) input 3 useable as interrupt (+24V, 5mA, 10 s) 2 x digital counter inputs (+5V, 5mA, 1 s) 8 x digital

More information

Inclination sensors 1-dimensional, measuring range

Inclination sensors 1-dimensional, measuring range Features Size 52 mm MEMS capacitive measuring principle EN13849 compliant firmware E1 compliant design Interface CANopen, SAE J1939, Analog Connection M12 and cable Protection up to IP 69K Optional GIM500R

More information

02/11/2015

02/11/2015 35 mm - 1 Relay 8A OUR1 Part number 88867105 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external

More information

Compact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ]

Compact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ] Compact performance Brief description CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8 English 8080251 2017-11e [8080244] Translation of the original instructions Documentation on the

More information

ASI Systems ML5740A Series

ASI Systems ML5740A Series ML5740A Series Electric Linear Valve Actuators Non-Spring Return APPLICATION The ML5740A series actuators operate standard ASI Systems valves in heating, ventilating and air conditioning (HVAC) applications.

More information

ASI Systems ML5720A Series

ASI Systems ML5720A Series ML5720A Series Electric Linear Valve Actuators Non-Spring Return APPLICATION The ML5720A series actuators operate standard ASI Systems valves in heating, ventilating and air conditioning (HVAC) applications.

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION SIM Card Connector, Hinged Type, 8 Pin, SMT, 1.50mm Profile. Page 1 SIM Card Connector, Hinged Type, 8 Pin, SMT, 1.50mm Profile. Page 2 1.0 SCOPE. This specification covers performance, tests and quality

More information

TM3AI4 module TM3-4 analog inputs

TM3AI4 module TM3-4 analog inputs Characteristics module TM3-4 analog inputs Main Range of product Product or component type Range compatibility Analogue input number 4 Analogue input type Complementary Analogue input resolution Permissible

More information

TLP100 INCLINATION SENSOR MEMS technology with High resolution

TLP100 INCLINATION SENSOR MEMS technology with High resolution CHARACTERISTICS ADVANTAGES MEMS technology High protection level IP67 and wide temperature range from -40 C... +85 C Stable accuracy over whole temperature range Resolution up to 0,01 Single axis 0 to

More information

C-DIAS Digital Input Module CDI 161 with 16 inputs

C-DIAS Digital Input Module CDI 161 with 16 inputs C-DIAS Digital Input Module CDI 161 with 16 inputs The CDI 161 is equipped with 16 inputs and one +24V level for reading the signal states "0" and "1". Appropriate input filters are available to suppress

More information

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident-No

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident-No PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass fiber reinforced housing Shock and vibration tested Fully potted module electronics

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through

More information

High-density multi-pin connectors

High-density multi-pin connectors High-density multi-pin connectors Mating and mounting conditions to DIN 41612/IEC 60603-2 General With the ever increasing miniaturization and higher packaging densities in highly integrated circuits there

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Positive-guided relay outputs: 5 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Connection

More information

Data Sheet for Joysticks

Data Sheet for Joysticks Finger Joystick Series 87 Dual redundant outputs IP67 sealed lever heights: 8mm and 60mm 5 lever colors Series 87 is offering paddle joysticks of high precision and quality - claims that are not only supported

More information

TSY 041 Training System Extension Motion

TSY 041 Training System Extension Motion TSY 041 Training System Extension Motion Date of creation: 02.11.2016 Version date: 02.11.2016 Article number: 12-100-041-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax:

More information

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s ElectroPneumatic Miniature Control Valves Order/Technical Support Tel: (800) 6773 / FAX: (800) 677386 / www.crouzetusa.com /47 Electropneumatic miniature control valves Mounting Connectors Minisolenoid

More information

MobileView Junction Box

MobileView Junction Box Installation Instructions MobileView Junction Box (Catalog Number 2727-MRJB2) English The MobileView Junction Box (2727-MRJB2) integrates the following terminals into the control system: MobileView Guard

More information

EtherNet/IP. Integrated Ethernet switch 10 Mbps / 100 Mbps supported 2 x male M12, 4-pin, D-coded, Ethernet-Fieldbus

EtherNet/IP. Integrated Ethernet switch 10 Mbps / 100 Mbps supported 2 x male M12, 4-pin, D-coded, Ethernet-Fieldbus EtherNet/IP Integrated Ethernet switch 10 Mbps / 100 Mbps supported 2 x male M12, 4-pin, D-coded, Ethernet-Fieldbus connection Glass fiber reinforced housing Shock and vibration tested Fully potted module

More information

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12 0 4 Remote I/O 8 channels for controlling HART control valves and positioners Intrinsically safe outputs Ex ia IIC Galvanic isolation between outputs and system Open-circuit and short-circuit monitoring

More information

GFK-2415A March Type of sensor connection

GFK-2415A March Type of sensor connection VersaMax IP Expansion Module has four analog differential inputs that can be configured as current or voltage inputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by

More information

C-DIAS Analogue Output Module CAO 081 for eight 10V DC outputs

C-DIAS Analogue Output Module CAO 081 for eight 10V DC outputs C-DIAS Analogue Output Module CAO 081 for eight 10V DC outputs This analogue output module is used for driving components capable of being analogue driven (e.g. proportional pressure valves, frequency

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

the Interactive Catalog

the Interactive Catalog Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to

More information

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous

More information

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output Product datasheet Characteristics XPSMF4000 Preventa safety PLC compact - Safe Ethernet Main Range of product Product or component type Safety module name Safety module application Preventa Safety automation

More information

Operating instructions Memory plug E /02 11/2011

Operating instructions Memory plug E /02 11/2011 Operating instructions Memory plug E30398 UK 704930/02 11/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Terms used...3 2 Safety instructions...4 3 Factory setting...4 4 Functions and features...5

More information