IDIS. Medium-Voltage Components. Intelligent Density Information System. Operation - Replacement Technical Instruction

Size: px
Start display at page:

Download "IDIS. Medium-Voltage Components. Intelligent Density Information System. Operation - Replacement Technical Instruction"

Transcription

1 Medium-Voltage Components IDIS Intelligent Density Information System Operation - Replacement Technical Instruction No. AGS Edition 08/0

2 Manufacturer: Schneider Electric Sachsenwerk GmbH Rathenaustrasse D Regensburg Germany ( +49 (0) (0) Service: Schneider Electric Sachsenwerk GmbH Rathenaustrasse D Regensburg Germany ( +49 (0) (0)

3 Contents Remarks on this manual...4 Purpose and target group... 4 Reference documents... 4 Terms and symbols used... 5 Abbreviations used... 5 Any questions or suggestions?... 5 Safety provisions...6 Design and function...7. Positions of gas density switches and of the display unit in panels IDIS Monitoring System in GHA Switchgear Panels Technical data Use in line with the intended purpose Disposal after the end of the service life Gas density switches... 4 IDIS display unit Description Display ranges Function test (on commissioning) Malfunction signals List of remote monitoring signals Replacement Safety provisions Replacement of the IDIS display unit Replace gas density switch Replacement devices and accessories Auxiliary products Gas density switch Protective cap for gas connector socket Versions of the display unit... AGS Edition 08/0 3

4 Remarks on this manual As our products are subject to continuous further development, we reserve the right to make changes regarding standards, illustrations and technical data. All dimensions specified in this manual are in millimeters. Purpose and target group This Technical Manual describes operation and replacement of the Intelligent Density Information System IDIS. It is exclusively intended for use by the manufacturer's staff or by persons certified for the IDIS system (training certificate). The work described in this manual may only be performed by specialist electricians with proven experience in conjunction with the GHA series (training certificate) all relevant safety provisions. the IDIS system This Technical Manual is an integral part of the product and must be stored so that it is readily accessible at all times for and can be used by persons who are to work on the switchgear. If the switchgear is relocated to another site, this Technical Manual must be passed on to the new operators along with the unit. This Technical Manual cannot describe every imaginable individual case or every customer-specific version of the product. For information which is not included in this manual, please contact the manufacturer. Reference documents The following additional documents must be observed: purchase agreement containing the stipulations on the specific equipment of the switchgear and the legal details the contract specific switchgearcircuit diagrams / documentation assembly Instructions for GHA switchgear operating Instructions for GHA switchgear GHA switchgear system configuration 4 AGS Edition 08/0

5 Remarks on this manual Terms and symbols used This manual uses certain terms and symbols. They warn about dangers or provide important information which must be complied with at all costs so as to avoid danger and damage: "Danger!" This danger symbol warns about dangerous electrical voltage. Contact with voltage may result in fatal injury! "Warning!" This danger symbol warns about the risk of injury. Please comply with all the provisions identified by this symbol in order to avoid death or serious injury. "Important:" This instruction symbol is used for information which is important to avoid material damage. Abbreviations used U r : I r : Rated voltage Rated current Any questions or suggestions? Do you have any questions or suggestions regarding this manual, or do you require further information? We always strive to provide you with the best-possible information for optimum, safe use of our products. Thus, do not hesitate to contact us if you have any recommendations, amendments or proposals for improvement. AGS Edition 08/0 5

6 Safety provisions The work described in this manual may only be performed by specialist electricians with proven experience in conjunction with the IDIS system and the applicable safety provisions. Read the instructions carefully before you work on the switchgear. Applicable standards and regulations: Metal-enclosed AC switchgear for rated voltages > kv up to including 5 kv: IEC Use and handling of sulphur hexafluoride (SF 6 ) in high-voltage switchgear: IEC The locally applicable accident prevention, operating and work instructions must be complied with. Installation: IEC 6936-/HD 637 S Operation of electrical equipment: EN 500- The national standards applicable in the country where the equipment is to be installed must be complied with. Before performing work on the panels, it is essential that you comply with the following instructions: Warning! Risk of injury from movable parts in mechanical drives. Before performing maintenance work, isolate the system from the supply voltage, release the circuit-breaker s energy storing device by OFF ON OFF operation switch ON via the make-proof earthing switch. Warning! After the removal of covers from a switchgear, operator safety regarding internal arcs may be reduced unless the switchgear is isolated from the power supply. Optimum operator safety is only ensured if the switchgear is completely isolated from the power supply and earthed for assembly work. Behaviour in case of incidents or accidents Whenever the IDIS system issues a malfunction signal as described in Chapter 4, its reason must be ascertained on site immediately. During a malfunction signal, the insulating gas density is not monitored, and thus, the dielectric strength of the high-voltage components concerned is not monitored either. The behaviour in case of malfunctions and accidents is also described in the operating manual for the series GHA. Make sure that first-aid measures are taken in case of injury to persons. Comply with the locally applicable accident and safety provisions. 6 AGS Edition 08/0

7 Design and function. Positions of gas density switches and of the display unit in panels Examples for GHA switchgear panels with single busbar gas density switches display unit The IDIS system consists of one up to max. three gas density switches and one display unit. SS LS L R SS re. SS li. LS Fig. Branch-circuit panel Fig. Bus section coupler Double busbar gas density switches display unit SS SS LS SS SS LS Definition for gas density switches in a panel with double busbar: Busbar = rear busbar Busbar = upper busbar Fig. 3 Branch-circuit panel Fig. 4 Bus coupler AGS Edition 08/0 7

8 Design and function SS re. SS li. LS SS re. SS li. LS Fig. 5 Bus section coupler of the upper busbar Fig. 6 Bus section coupler of the rear busbar Busbar attachments for double busbar gas density switches display unit MB TB MB TB Definition for gas density switches in a panel with double busbar: Busbar = rear busbar Busbar = upper busbar Fig. 7 Busbar earthing switch Fig. 8 Double busbar metering panel with disconnectable busbar voltage transformers 8 AGS Edition 08/0

9 Design and function. IDIS Monitoring System in GHA Switchgear Panels Important: The rated pressure and the pick-up values of the IDIS system are indicated on the switchgear panel's nameplate and its Operating Manual. Busbar gas compartments Electrical bushing (gas-tight) Gas connector socket Gas density switch Circuit breaker gas compartments Pressure relief port IDIS display unit Fig. 9 GHA switchgear with single busbar Busbar gas compartments (= rear busbar) Busbar gas compartments (= upper busbar) Electrical bushing (gas-tight) Gas connector socket Gas density switch Circuit breaker gas compartments Pressure relief port IDIS display unit Fig. 0 GHA switchgear with double busbar AGS Edition 08/0 9

10 Design and function.3 Technical data Ambient conditions Operating temperature range Temperature range for storage and transport -5 C up to +55 C -40 C up to +70 C Auxiliary supply/ power consumption Auxiliary voltage max. power consumption 4 V DC, admissible fluctuation range ± 0%, with polarity-reversal protection 50 ma Contact data of signalling relays Rated power (resistive) max. switching capacity max. switching voltage max. DC load (resistive) 5 A / 50 V AC 5 A / 30 V DC 50 VA / 50 W 50 V AC / 0 V DC 0,4 A / 0 V DC Requirements/standards acc. to IEC , test Alternating Voltage value kv Insulation strength acc. to IEC , class 3, Impulse voltage test value 5 kv EMC requirements acc. to IEC 6000 Mechanical requirements Resistance to earthquakes in accordance with EN 6055 Operating conditions normal service conditions in acc. to IEC67-, temperature class "minus 5 C indoor".4 Use in line with the intended purpose The Intelligent Gas Density Information System IDIS is exclusively intended to monitor gas-insulated medium-voltage switchgear units. It may only be used in the scope of the specified standards and the switchgear-specific technical data. Any other utilization constitutes improper use and may result in dangers and damage. Disclaimer of liability The manufacturer shall not be held responsible for damage which occurs if instructions in this technical manual are not complied with, the IDIS system is not operated appropriately (see above), the IDIS system is assembled, connected or operated improperly, accessories or spare parts are used which have not been approved by the manufacturer, the IDIS system is converted without the manufacturer's approval, or if inadmissible parts are attached..5 Disposal after the end of the service life The disposal of the components of the IDIS system is described in the scope of the disposal of the switchgear panel pertaining to it. Disposal at the end of the service life is performed as a service by the Service Center at the manufacturer's which is subject to a fee. 0 AGS Edition 08/0

11 3 Gas density switches The gas density switches are screwfastened to the gas connector sockets of the appropriate cladded compartments (Fig. ). They can be replaced at any time. The gas density switches are temperature-compensated. If the insulating gas temperature changes, the output value remains constant, as a temperature change does not change the insulating gas density. The gas density switch features two NO contacts. The NO contacts define two response thresholds which transmit three differentiated messages to the IDIS display unit, depending on the switch condition (Fig. ). 3 4 Fig. Gas density switch Connection cable to display unit 3 Swivel nut 4 Gas connector socket Gas-filled compartments 3 P P P3 Remote signalling. warning level. warning level Gas density switches IDIS display unit Fig. IDIS schematic diagram AGS Edition 08/0

12 4 IDIS display unit 4. Description The temperature-compensated gas density information system IDIS represents the signals of the max. 3 gas density switches connected in terms of colour-coded LEDs. Remote signalling relays on the back enable signals to be transmitted to a remote control or I&C system. The display unit evaluates the signals of each gas density switch and indicates the insulating gas states "ready to operate", " warning level" and ". warning level" via three LED per channel. A status change must be present constantly for at least three seconds before the input is evaluated (signal debounce) Fig. 3 IDIS display unit, showing for example a circuit-breaker panel with single busbar; variants see chapter 6.4, page Nameplate Schematic diagram 3 Colour LED ready for operation 4 Colour LED warning level 5 Colour LED warning level 6 Monitoring of busbar compartment 7 non-activated channel 8 Monitoring of circuit-breaker compartment 9 Function test push-button AGS Edition 08/0

13 4 IDIS display unit 4. Display ranges The table below shows the three possible insulating gas states which can be represented by the indicator unit for each active channel. The data is referred to a compartment monitored by a gas density switch. Warning! For reasons of operator safety, covers must not be removed during operation. Refer to the safety provisions in section. Important: The rated pressure and the. warning level of the IDIS system are indicated on the switchgear panel's nameplate. Always comply with the operating manual of the switchgear. Messages of the IDIS display unit per channel / actions to be taken in case of a loss of density (within the compartment) For use and handling of sulphur hexafluoride (SF 6 ) in high-voltage switchgear, IEC must be complied with. LED display grün State ready for operation State of remote signalling relays Both remote signalling relays picked up Actions to be taken gelb rot. warning level in case of pressure drop. warning level in case of pressure drop Remote signalling relay " st warning level" dropped, " nd warning level" remains pickedup Remote signalling relay " nd warning level" dropped, " st warning level" is picked up again Contact Service-Center Replenish insulating gas and watch the system to find out if the. warning level reoccurs Schedule a disconnection of the compartment in question Contact Service-Center Isolate the corresponding compartment from power supply Warning! Insulating gas may only be refilled by trained specialist staff. Comply with the valid safety instructions and data sheets. AGS Edition 08/0 3

14 4 IDIS display unit 4.3 Function test (on commissioning) Warning! High voltage must not be connected until the function test has been performed successfully, as the the insulating gas monitoring is not ensured. Actions to be taken in case of malfunctions:. Use a pointed object (e.g. pen) to press the push-button in the opening on the front labelled "" (Fig. 4.5). Now all LEDs of the active channels must go on. Both remote signalling relays must drop out at the same time and issue the. warning level and the. warning level.. Release the button; the IDIS system returns to its normal operation.. Do not commission the panel!. Replace display unit (see section 5). < << Push-button for function test Fig. 4 Function test: All active LED must go on and the remote signalling relays issue pre-alarm and main alarm. 4.4 Malfunction signals Malfunction signals have priority over loss-of-density signals if both are present simultaneously. Specificities for remote monitoring: Warning! As long as malfunction signals are active, high voltage must not be connected on commissioning due to the fact that there is no insulating gas monitoring. The insulating gas monitoring is not ensured while a malfunction signal is on. Important: During all malfunction signals of the IDIS system, both remote signalling relays at the display unit are, on principle, in drop-out status and issue the signals pre-alarm and main alarm at the same time. Action: The reason for the malfunction signal must be clarified immediately on site based on the LEDs. Warning! Refer to the safety provisions in section. 4 AGS Edition 08/0

15 4 IDIS display unit Display unit: The IDIS system performs a selfdiagnosis at intervals of 5 seconds. If a fault is detected the yellow and the red LEDs on all active channels are lit (Fig. 5). Both remote signalling relays drop out. Action: Replace display unit (see section 5). < << Line monitoring to the gas density switches Due to the closed-circuit principle, the lines to the gas density switches are monitored. If a connection cable is interrupted, the yellow and the red LEDs of the channel in question flash (Fig. 4.3). Both remote signalling relays drop out. (Fig. 6). Actions:. Check the connection cable / plug-in contacts to the gas density switch (see section 5).. If necessary, check the gas density switch and the gas density of the compartment in question (Contact the manufacturer). Fig. 5 All active yellow and red LEDs are lit: System alarm < << Fig. 6 In the lower channel, the yellow and the red LED flash: Check the connection cable for the appropriate gas density switch - in this case the circuit-breaker compartment. Supply voltage not available As long as there is no supply voltage present, all LEDs on the display unit are inactive (Fig. 7). Both remote signalling relays drop out. Actions:. Apply supply voltage.. Check contacts and supply cable. Inform the manufacturer. < << Fig. 7 None of the LEDs is lit. The power supplyis not available. AGS Edition 08/0 5

16 4 IDIS display unit 4.5 List of remote monitoring signals A total of five different states of the IDIS system are retransmitted via the two remote signalling contacts. Important: Whenever the IDIS system issues an alarm and malfunction signal, its reason must be ascertained on site immediately. Remote signals from the IDIS system State of the two remote signalling relays Actions Operative Both relays are picked up Pre-alarm (Insulating gas density) Main alarm (Insulating gas density) Relay "pre-alarm" dropped out ("Main alarm" remains picked up) Relay "Main alarm" is dropped out and "pre-alarm" picks up again. see chapter 4., page 3 see chapter 4., page 3 Malfunction signal Both relays are dropped out see chapter 4.4, page 4 Function test Both relays must drop out see chapter 4.4, page 4 6 AGS Edition 08/0

17 5 Replacement 5. Safety provisions IDIS units may only be replaced by specialist electricians with proven experience in conjunction with the IDIS system and the applicable safety provisions. Danger! Prior to performing work in the area of the panel drives, switch the supply voltage OFF and make sure to prevent reclosure. Warning! Risk of injuries while working in the area of the drives. Before commencing work, release the circuit-breaker s energy storing device by performing the sequence of operations OFF-ON-OFF. Warning! Loss of insulating gas causes a risk of internal faults within the compartment, as there is no insulation strength. Do not open the gas tanks! Warning! After the removal of covers from switchgear, operator safety regarding internal faults may be impaired unless the switchgear is isolated from the power supply. Optimum operator safety is only ensured if the switchgear is completely disconnected from the power supply and earthed during assembly. These replacement instructions describe exclusively the disassembly and assembly of the gas density switch and the display unit. To have access to the devices, covers may have to be removed or dismounted, depending on the panel types and variant. AGS Edition 08/0 7

18 5 Replacement 5. Replacement of the IDIS display unit Fig. 8 Assignment of rear socket contacts on the display unit. Shown: double busbar feeder panel (Exception: bus section coupler) Remote signalling contacts Power supply terminal Connectors for gas density switch: 3 Busbar compartment 4 Busbar compartment 5 Circuit-breaker compartment Removal. The operating panel in which the IDIS display unit has been mounted should be removed depending on the ease of access. Observe the assembly instructions of the switchgear panel!. Remove the connectors for remote signalling, power supply and the gas density switch. 3. Press both retaining clips outwards and remove display unit to the rear (Fig. 9). Fig. 9 Press retaining clips to the side () and pull IDIS device out () Assembly. Place both retaining clips in the sheet-metal cut-out and press them outwards slightly. Push the display unit in the sheet-metal cut-out from the rear, until the retaining clips are engaged in the display unit (Fig. 0).. Reconnect the connector for remote signalling, power supply and the gas density switch according to the socket contact assignment (Fig. 8, page 8). 3. Check the display unit for proper working order (see chapter 4.3). 4. Remount the covers which were removed previously. Fig. 0 Press clip outwards () and push IDIS device inwards until it locks in () 8 AGS Edition 08/0

19 5 Replacement 5.3 Replace gas density switch Warning! Risk of leakage: When removing and remounting the gas density switch, the gas connector socket must be held up (locked; wrench size 3).. Remove the three-pole connector of the gas density switch from the display unit and pull connection cable back to the gas density switch.. Release swivel nut (wrench size 3) between the gas density switch and the gas connector socket. 3. Pull the gas density switch off (Fig. ). At the same time, the valve of the gas connector socket is closed automatically. 4. Should no replacement unit be available during disassembly, the gas connector socket must be closed by means of a cap (Fig. ) 3 4 Fig. Gas density switch Connection cable to display unit 3 Swivel nut 4 Gas connector socket Fig. Cap Ref.-No.: AGS C Assembly. Remove cap (Fig. ) from the gas connector socket.. Coat seal and sealing surfaces (required auxiliary products, see Chapter 6., page 0). Sealing surfaces, seals (cord sealing rings) and grooves for cord sealing rings must be cleaned with particular care using a cleaning agent and a lint-free cloth. Immediately afterwards, apply SF6 multi-purpose lubricant using a nylon brush or a leather cloth which is exclusively reserved for this application; then keep the brush or the leather cloth in a place where it is protected against soiling. Important: Sealing surfaces coated with SF 6 multi-purpose lubricant must no longer be touched. Any contamination may impair function (leakage). 3. Push gas density switch into the gas connector socket and secure it using the swivel nut (Fig. 5.4). Tightening torque: Nm 4. Route connecting cable to the IDIS display unit and - if necessary - fasten it to the panel; reel up excessive cable lengths. 5. Connect the three-pole connector of the gas density switch to the appropriate socket contact. 6. Perform a functional check on the display unit and check malfunction signals (see Chapter 4.3 and 4.4). 7. Remount the panel shutters which have been removed previously. AGS Edition 08/0 9

20 6 Replacement devices and accessories 6. Auxiliary products Warning! Risk of injury if these products are handled improperly. Observe the safety data sheets of the manufacturers of the auxiliary products. Only the following auxiliary products may be used, which can be purchased from the manufacturer. The use of other auxiliary products is not admissible. Designation Ref. No. SF 6 multi-purpose lubricant MS, 0.75 kg can ST Detergent (ethanol, type 64) S Please enquire at the manufacturer s regarding the available packing unit. 6. Gas density switch Rated pressure Ref. No. p re 0,03 MPa AGS ,05 MPa AGS ,06 MPa AGS The rated pressure of the panel is indicated on its nameplate. The specified pressure data refer to +0 C and an atmospheric pressure of 0.3 kpa absolute. Fig. 3 Gas density switch with signal line 6.3 Protective cap for gas connector socket Ref. No.: AG C05690 Fig. 4 Cap with packing ring 0 AGS Edition 08/0

21 6 Replacement devices and accessories 6.4 Versions of the display unit Depending on the design of the switchgear panels, panel-specific IDIS display units are used. The design in question depends on the panel configuration and can be identified by means of the schematic diagram on the IDIS display unit. Important: Other customized busbar designations must be taken into consideration analogously. IDIS display units for single busbar switchgear Single busbar "BB" = busbar compartment "CB" = circuit-breaker compartment Feeder panel with circuit-breaker Ref.-No.: AGS BB CB Busbar riser panel Ref.-No.: AGS BB CB Panel, only with busbar Ref.-No.: AGS BB Bus section coupler Ref.-No.: AGS BB r. BB l. CB AGS Edition 08/0

22 LS IDIS 6 Replacement devices and accessories IDIS display units for double busbar switchgear Double busbar "BB" = busbar (rear busbar compartment) "BB" = busbar (upper busbar compartment) "CB" = circuit-breaker compartment Feeder panel with circuit-breaker Ref.-No.: AGS BB BB CB Busbar riser panel Ref.-No.: AGS BB BB CB Panel, only with busbars Ref.-No.: AGS BB BB Bus coupler Ref.-No.: AGS BB BB CB Bus section coupler in a panel width ( display units per panel) Busbar with bus section coupler Ref. no.: AGS Display units are identical for bus section couplers of the upper and rear busbar. Regarding assignment of the monitored compartments, observe the panel s mimic diagram. Continuous busbar Ref. no.: AGS BB r. BB l. CB Special model for ANSI version ( display units per panel) Compartment for circuit-breaker (CS) cable connection (CC) Ref. no.: AGS CS CC Compartment for main busbar (MB) transfer busbar (TB) Ref. no.: AGS MB TB AGS Edition 08/0

23

24 Schneider Electric 0 All rights reserved to this technical manual. Reproduction and making available of this technical manual, or extracts, to third parties are prohibited. Only integral reproduction of this technical manual is permitted with the written permission from Schneider Electric. Electronic copies in e.g. PDF-format or scanned version have the status for information only. The only valid version of this technical manual is always enclosed directly to the product in question by the factory. Schneider Electric 35, rue Joseph Monier CS Rueil-Malmaison Cedex, France RCS Nanterre Capital social AGS /0 As our products are subject to continuous development, we reserve the right to make changes regarding the standards, illustrations and technical data described in this Technical Manual. For any requests, please contact the address given below. Schneider Electric Sachsenwerk GmbH Rathenaustrasse D Regensburg, Germany ( +49 (0) (0)

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Camera system for isolating and earthing switch (Single Busbar Panels)

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Camera system for isolating and earthing switch (Single Busbar Panels) Gas-Insulated Switchgear GHA Gas-Insulated Switchgear Camera system for isolating and earthing switch (Single Busbar Panels) (Supplement to the operating manual) No. AGS 53 059-0 Edition 09/204 www.schneider-electric.com

More information

GHA. Gas-Insulated Circuit-Breaker Switchgear Unit up to 40.5 kv. Gas-Insulated Switchgear. Customer Benefits

GHA. Gas-Insulated Circuit-Breaker Switchgear Unit up to 40.5 kv. Gas-Insulated Switchgear. Customer Benefits 01 Gas-Insulated Circuit-Breaker Switchgear Unit up to 40.5 kv PM103255 Energy supply security is our permanent challenge. At Schneider Electric, we are constantly developing and improving our products

More information

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Original operating instructions Fail-safe inductive sensor GF711S / / 2013 Original operating instructions Fail-safe inductive sensor GF7S 8528 / 5 / 23 Contents Preliminary note...3. Explanation of symbols...3 2 Safety instructions...4 2. Safety-related requirements regarding

More information

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

English. Operating Manual. Conductive point level switch MLR120.  Retain for later reference. Companies / brands of GHM English Operating Manual Conductive point level switch MLR120 Companies / brands of GHM www.ghm-group.de Retain for later reference Table of contents Page 1. Proper use (application areas)... 3 Safety

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Original operating instructions Fail-safe inductive sensor GI711S / / 2010 Original operating instructions Fail-safe inductive sensor GI7S 704583 / 0 06 / 200 Contents Preliminary note 3. Explanation of symbols 3 2 Safety instructions 4 2. Safety-related requirements regarding

More information

ABB AG Calor Emag Medium Voltage Products Gas-insulated switchgear Type ZX2. ABB Gas-insulated switchgear type ZX2 1

ABB AG Calor Emag Medium Voltage Products Gas-insulated switchgear Type ZX2. ABB Gas-insulated switchgear type ZX2 1 ABB AG Calor Emag Medium Voltage Products Gas-insulated switchgear 17.02.2015 Gas-insulated switchgear type ZX2 1 Medium voltage switchgear type ZX2 Single or double busbar systems 12 kv, 2500 A, 40 ka

More information

ABB AG - EPDS. Gas-insulated switchgear Type ZX2

ABB AG - EPDS. Gas-insulated switchgear Type ZX2 ABB AG - EPDS Gas-insulated switchgear Medium voltage switchgear Single or double busbar systems 12 kv, 2500 A, 40 ka 24 kv, 2500 A, 40 ka 36 kv, 2500 A, 40 ka Slide 2 Medium voltage switchgear With IAC

More information

Original operating instructions Fail-safe inductive sensor GI712S

Original operating instructions Fail-safe inductive sensor GI712S Original operating instructions Fail-safe inductive sensor GI712S 80236527 / 00 12 / 2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warning signs used...3 2 Safety instructions...4 2.1 Safety-related

More information

SolConeX extra-low voltage flange socket

SolConeX extra-low voltage flange socket SolConeX extra-low voltage flange socket Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3

More information

Original operating instructions Fail-safe inductive sensor GG711S

Original operating instructions Fail-safe inductive sensor GG711S Original operating instructions Fail-safe inductive sensor GG7S 8236522 / 2 / 26 Contents Preliminary note...3. Symbols used...3.2 Warning signs used...3 2 Safety instructions...4 2. Safety-related requirements

More information

Overview of types. Technical data

Overview of types. Technical data echnical data sheet SH2A-MF.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control

More information

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date: Operating instructions for AX5801 TwinSAFE drive option card for the AX5000 servo drive Version: 1.2.0 Date: 2016-03-15 Table of contents Table of contents 1 Foreword 3 1.1 Notes on the manual 3 1.1.1

More information

Operating Instructions

Operating Instructions TPS S1 AC in DC out Translation of the original instructions TPS 110-400 Mains pack Operating Instructions PT 0199 BEN/C (1010) EN Table of contents Table of contents 1 About this manual...............................................

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...) 7 818 Actuators SQM9... Electromotoric actuators Torques up to 60 Nm Running times ¹) 30...120 s ¹) Predefined by the basic unit (LMV5...) The SQM9... and this Data Sheet are intended for use by OEMs which

More information

Operating Instructions VEGAMET 381

Operating Instructions VEGAMET 381 Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...

More information

Operating Manual -ENGLISH- Page 1 KWG-ISO

Operating Manual -ENGLISH- Page 1 KWG-ISO Page 1 KWG-ISO Operating manual English- Status May 2013 Page 2 Manufacturer address KW-Generator GmbH & Co.KG Bänglesäcker 24 73527 Schwäbisch-Gmünd / Lindach Phone: +49 (0) 7171 104 17 0 Fax: +49 (0)

More information

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1 INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1 TOSHIBA Corporation 2004 All Rights Reserved. ( Ver. 1.6 ) Safety Precautions Before using this product, please read this chapter carefully. This

More information

Operating Instructions

Operating Instructions Key Adapter CKS-K-AS2A-U-C20-PC (Unicode) EN Contents 1. About this document... 3 1.1. Scope...3 1.2. Target group...3 1.3. Key to symbols...3 1.4. Supplementary documents...3 2. Correct use... 4 3. Description

More information

IEC & 2 standard. The reference for safe and reliable LV switchboards

IEC & 2 standard. The reference for safe and reliable LV switchboards IEC 61439-1 & 2 standard The reference for safe and reliable LV switchboards IEC61439-1 & 2 The power of a standard adapted to your needs IEC standards are today legal or market references. The new IEC

More information

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content 7 Set-up and maintenance 7.1 Functional testing....10 7.2 Maintenance...10 EN Operating instructions.............pages 1 to 6 Original 8 Disassembly and disposal 8.1 Disassembly....10 8.2 Disposal...10

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter Installation, Operation & Maintenance Sheet Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter > Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2

More information

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date: Documentation Sixteen Channel Digital Output Module with D-Sub Connector Version: Date: 2.0 2016-08-03 Table of contents Table of contents 1 Foreword... 4 1.1 Notes on the documentation... 4 1.2 Safety

More information

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date: Documentation Sixteen channel digital output module with D-Sub Connector Version: Date: 2.0.0 2017-11-20 Table of contents Table of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1.2 Safety

More information

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date: Documentation KM2604 and KM2614 Four channel relay module Version: Date: 2.1.0 2017-12-01 Tabel of contents Tabel of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1.2 Safety instructions...

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V Innovative by tradition. Control unit SG-EFS 104/4L EN Operating instructions Version 2 1004128 SG-EFS 104/4L AC/DC 24 V Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date: Documentation Fan cartridge for EtherCAT and Bus Terminals Version: Date: 1.5 2017-08-07 Table of contents Table of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1.2 Safety instructions...

More information

Pressure switch RE B/ Type HEDE10.../1/ Operating instructions

Pressure switch RE B/ Type HEDE10.../1/ Operating instructions Pressure switch Type HEDE10.../1/ RE 30276-B/10.10 Replaces: 06.10 Operating instructions 2/20 Bosch Rexroth AG HEDE10.../1/ RE 30276-B/10.10 Contents 1 Overview of menu...3 2 Safety note... 4 3 Operating

More information

SolConeX Wall-Mounted Socket, 16 A

SolConeX Wall-Mounted Socket, 16 A SolConeX Wall-Mounted Socket, 16 A Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information Regarding the

More information

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~ Innovative by tradition. Control unit SG-EFS 104/2W EN Operating instructions Version 0.9 1005196 SG-EFS 104/2W 24 V=/~ Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

QUICK START GUIDE. vau4/3. Frequency converter.   operating instructions /12 operating instructions QUICK START GUIDE Frequency converter vau4/3 28100241101 12/12 1 Safety information Warning of electrical shock! Danger to life! Electrical shock can cause serious injury or even

More information

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3 Operating Instructions Control Unit SG-EFS 1X4 ZK2/1 8k2 Version 3 1003100 SG-EFS 104 ZK2/1 8k2 24 V=/~ 7500354 SG-EFS 134 ZK2/1 8k2 230 V~ Original instructions GmbH & Co. KG Polymer Electric Örlinger

More information

Type VR Electrically Operated Ground and Test Device

Type VR Electrically Operated Ground and Test Device Type VR Electrically Operated Ground and Test Device For Use with Masterclad Switchgear 4.76 kv 15 kv, 1200, 2000, 3000, 4000 A Up to 63 ka Short Circuit Rating Class 6055 Instruction Bulletin 6055-37

More information

GV204 Impulse Splitter for Incremental Encoders

GV204 Impulse Splitter for Incremental Encoders Operating Manual www.genesisautomationonline.com GV204 Impulse Splitter for Incremental Encoders Product features: Programmable encoder input A, /A, B, /B, Z, /Z, for use with RS422 or TTL differential

More information

SWITCHGEAR MODELS CEP 14 / 15

SWITCHGEAR MODELS CEP 14 / 15 PRODUCT LEAFLET SWITCHGEAR MODELS CEP 14 / 15 For network 950 V - 3,200 V - 5,500 V - 6,600 V Switchgear with three compartments Outgoing feeder contactor Switchgear with two compartments Outgoing feeder

More information

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B Safety Relay for Emergency Stop and Safety Door Circuits INTERFACE Data Sheet 102858_02_en PHOENIX CONTACT - 12/2006 Description The PSR-...- 24DC/SDC4/2X1/B

More information

DALI Professional Controller-4. Control unit Operating instructions

DALI Professional Controller-4. Control unit Operating instructions LI Professional Controller-4 Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Configuration 5 Design 5 Connections

More information

PowerLogic High Density Metering System 1-Meter Enclosure

PowerLogic High Density Metering System 1-Meter Enclosure PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these

More information

Product and Function Description

Product and Function Description Product and Function Description and the LED display. The touchscreen can be used to select from up to 6 languages for the display of texts and messages. The room temperature controller integrated in Contouch

More information

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x 1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical

More information

B63/ NS MS. EtherNet/IP LINK

B63/ NS MS. EtherNet/IP LINK 3 609 929 B63/ IMenip 2008-09 NS MS EtherNet/IP LINK 3 609 929 B63/2008-09 IMenip Bosch Rexroth AG 15/76 Table of Contents About this document................. 16 General safety instructions............

More information

Documentation. Mains filter AX2090-NF50. Version: Date:

Documentation. Mains filter AX2090-NF50. Version: Date: Documentation Mains filter AX2090-NF50 Version: Date: 1.1 2015-11-11 Table of content Table of content 1 Foreword... 4 1.1 Notes on the documentation... 4 1.2 Documentation issue status... 5 1.3 Appropriate

More information

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011 Technical Data 2CDC505082D0203 ABB i-bus KNX Product description Switch Actuators SA/S x.16.6.1, 16/20 A are modular installation devices in ProM design for installation in the distribution board. They

More information

Operating Manual FPGA-based High-Speed Micro-PLC

Operating Manual FPGA-based High-Speed Micro-PLC ZX20T Operating Manual FPGA-based High-Speed Micro-PLC Zander GmbH & Co. KG Am Gut Wolf 15 52070 Aachen, Deutschland info@zander-aachen.de www.zander-aachen.de Part No.: E61-335-10 Edition: H03 This document

More information

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3 Operating Instructions Control Unit SGRST 153 Version 0.3 1004931 SGRST 153 Original instructions GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY Tel.: +49 731 20610 Fax: +49 731 2061222 EMail: info.ulm@mayser.com

More information

Polymer Electric. Operating Instructions. Control Unit SG-TRS 3X8. Version 1

Polymer Electric. Operating Instructions. Control Unit SG-TRS 3X8. Version 1 Operating Instructions Control Unit SGTRS 3X8 Version 1 100597 SGTRS 318 110 V= 100596 SGTRS 38 4 V= Original instructions GmbH & Co KG Örlinger Straße 1 3 89073 Ulm GERMANY Tel: +49 731 0610 Fax: +49

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft echnical data sheet LH24A-MF2-P Parmeterisable linear actuator for adjusting dampers and slide valves in technical building installations Air damper size up to approx. m² Actuating force 5 N Nominal voltage

More information

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3. Preface 1 Properties 2 SIMATIC Diagnostics 3 ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02- Manual 01/2008 A5E01254028-01 Safety Guidelines This manual contains notices

More information

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool echnical data sheet LHA-MF..-P Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control

More information

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions Device with II 2G EX i approval Geräte mit II 2G EX i Zulassung Appareils avec mode de protection II 2G EX i Example / Beispiel / Exemple Type 6106 Operating Instructions Bedienungsanleitung Manuel d utilisation

More information

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits

More information

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2. SIMATIC ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01- SIMATIC Preface Properties 1 Diagnostics 2 ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A

More information

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions , Equipment protection fuse with Ex mb II C Gb approval Geräteschutzsicherung mit Zulassung Ex mb II C Gb Fusible de protection d appareil avec homologation Ex mb II C Gb Example / Beispiel / Exemple:

More information

Documentation KL channel Digital Output Terminal, 24 V DC, 2 x 4 A/1 x 8 A. Version: Date:

Documentation KL channel Digital Output Terminal, 24 V DC, 2 x 4 A/1 x 8 A. Version: Date: Documentation 2 channel Digital Output Terminal, 24 V DC, 2 x 4 A/1 x 8 A Version: Date: 1.0.0 2016-08-12 Table of contents Table of contents 1 Foreword... 4 1.1 Notes on the documentation... 4 1.2 Safety

More information

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example... 7 ppendix 7.1 Wiring example...5 8 Declaration of conformity 8.1 EC Declaration of conformity...6 Operating instructions.............pages 1 to 6 Translation of the original operating instructions x.000

More information

Operating Instructions. DALI-Gateway

Operating Instructions. DALI-Gateway Operating Instructions 1. Safety instructions Electrical equipment must be installed and fitted by qualified electricians only. Failure to observe the instructions may cause damage to the device and result

More information

FUE 10 FUE-M/S 85A FUE-M/S 86A

FUE 10 FUE-M/S 85A FUE-M/S 86A www.wackergroup.com 0109972en 001 02.2007 Inverter FUE 10 FUE-M/S 85A FUE-M/S 86A Operator's manual 1. Foreword Foreword For your own safety and protection from bodily injuries, carefully read, understand

More information

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION H Series PLC EH-150 Analog input module EH-AXH8M Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction manual and all the

More information

Operating and installation instructions Differential pressure monitor

Operating and installation instructions Differential pressure monitor Operating and installation instructions Differential pressure monitor RM-DPC Micro SensorLine Table of contents 1 Safety instructions...3 2 Equipment specification...3 3 Assembly...4 4 Step-by-step installation...4

More information

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s Safety information 1 General information 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

Operating Instructions

Operating Instructions Innovative by tradition. Operating Instructions Control Unit SG-RSV 239 Version 1 1003986 SG-RSV 239/24 24 V= 1005372 SG-RSV 239/36 36 V= 1003271 SG-RSV 239 50-150 V= Mayser GmbH & Co. KG Örlinger Straße

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

Documentation. CU20xx, CU22xx. Ethernet Switch. Version: Date:

Documentation. CU20xx, CU22xx. Ethernet Switch. Version: Date: Documentation CU20xx, CU22xx Ethernet Switch Version: Date: 2.1 2017-12-18 CU20xx, CU22xx - Product overview 1 CU20xx, CU22xx - Product overview CU2005 [} 8] - 5 RJ-45-Ethernet-Ports CU2008 [} 8] - 8

More information

Druck DPI 620 advanced modular calibrator

Druck DPI 620 advanced modular calibrator GE Sensing & Inspection Technologies A1.1 DPI 620: Channel 1 (CH1) Druck DPI 620 advanced modular calibrator safety and quick reference guide - K0454 Measure (M) / Source (S) / Power (P) a ±30 V (M) b

More information

Fieldbus Independent I/O Modules 8 DI DC 24 V 3.0 ms, Manual

Fieldbus Independent I/O Modules 8 DI DC 24 V 3.0 ms, Manual Fieldbus Independent 8 DI DC 24 V 3.0 ms, 750-436 Manual Version 1.0.1 ii Important Comments Copyright 2006 by WAGO Kontakttechnik GmbH & Co. KG All rights reserved. WAGO Kontakttechnik GmbH & Co. KG Hansastraße

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. Preface SIMATIC ET 200S distributed I/O Digital electronic module 2RO NO/NC DC24..48V/5A AC24..230V/5A (6ES7132-4HB50-0AB0) SIMATIC ET 200S distributed I/O Digital electronic module 2RO NO/NC DC24..48V/5A

More information

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3 Overview Safety notes 1 SITOP power supply Manual Description, device design, dimension drawing 2 Mounting/removal 3 Mounting position, mounting clearances 4 Installation 5 Technical data 6 Safety, approvals,

More information

TeSys UASILUFC5 - ASILUFC51 AS-i Communication Module

TeSys UASILUFC5 - ASILUFC51 AS-i Communication Module 1639093 03/2009 TeSys UASILUFC5 - ASILUFC51 AS-i Communication Module User Manual 03/2009 1639093 www.schneider-electric.com Schneider Electric assumes no responsibility for any errors that may appear

More information

Installation instructions Inclination sensor EC2019 EC / / 2013

Installation instructions Inclination sensor EC2019 EC / / 2013 Installation instructions Inclination sensor UK EC219 EC245 739215 / 3 1 / 213 Inhalt 1 Safety instructions 3 2 Mounting 4 3 Electrical connection 4 4 Dimensions 4 5 Technical Data 5 6 Characteristics

More information

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval.

More information

Fieldbus Independent I/O Modules 4 AI Pt100/ RTD , (/xxx-xxx) Manual

Fieldbus Independent I/O Modules 4 AI Pt100/ RTD , (/xxx-xxx) Manual Fieldbus Independent 4 AI Pt100/ RTD 750-460, (/xxx-xxx) Manual Version 1.0.2 ii General Copyright 2006 by WAGO Kontakttechnik GmbH & Co. KG All rights reserved. WAGO Kontakttechnik GmbH & Co. KG Hansastraße

More information

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range echnical data sheet AV4-MF()(-C105) Multi-functional linear actuators for -way and 3-way globe valves Actuating force 500 N Nominal voltage AC/DC 4 V Control: modulating DC 0 10 V Position feedback DC

More information

MiCOM P122C Time-Overcurrent Protection

MiCOM P122C Time-Overcurrent Protection Protection Relays 01 MiCOM P122C Time-Overcurrent Protection Customer Benefits 1A/5A software setting 4 function keys Compact unit for flush and wall-surface mounting Comprehensive measurements Disturbance

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

GV150 / GV151 Impulse amplifier and splitter for incremental encoder signals

GV150 / GV151 Impulse amplifier and splitter for incremental encoder signals Operating Manual GV150 / GV151 Impulse amplifier and splitter for incremental encoder signals Product features: Impulse input (, /, B, /B, Z, /Z, level or level) Potential separation by high speed optocouplers

More information

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0) 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32- SIMATIC Preface 1 Properties 2 Diagnostics 3 ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32- Manual 10/2015

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

VIP 40/45 VIP 400/410

VIP 40/45 VIP 400/410 40/45 400/410 Selection guide 01 PM100573 40/45 PM100576 400/410 self-powered integrated protection relay Optimised performance for transformer, incomer, feeder and bus riser protection Complete engineered

More information

Fieldbus Independent I/O Modules 1 AI DMS Manual

Fieldbus Independent I/O Modules 1 AI DMS Manual Fieldbus Independent 1 AI DMS 750-491 Manual Version 1.1.4 ii General Copyright 2005 by WAGO Kontakttechnik GmbH & Co. KG All rights reserved. WAGO Kontakttechnik GmbH & Co. KG Hansastraße 27 D-32423 Minden

More information

CPCI-PS24 24V-Power Supply

CPCI-PS24 24V-Power Supply 24V-Power Supply Hardware Manual to Product I.2301.21 esd electronic system design gmbh Vahrenwalder Str. 207 30165 Hannover Germany http://www.esd.eu Phone: +49 (0) 511 3 72 98-0 Fax: +49 (0) 511 3 72

More information

METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no.

METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no. METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no. 20 751 979 Distributor: Manufacturer: METREL d.d. Ljubljanska cesta 77 1354 Horjul

More information

MiCOM P521. Fast Feeder Differential Protection

MiCOM P521. Fast Feeder Differential Protection 01 Fast Feeder Differential Protection The relay provides high-speed two-ended current differential unit protection of overhead lines and underground cables in applications such as ring mains and parallel

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

Installation and commissioning guide SmartLink PSD Power Supply Module (DC) Installation and commissioning guide SmartLink PSD Power Supply Module (DC) Rev. 1 September 2012 Part No. 4417551 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15

More information

Installation Instructions Temperature transmitter TAA /00 06/2011

Installation Instructions Temperature transmitter TAA /00 06/2011 Installation Instructions Temperature transmitter TAA431 706042/00 06/2011 Contents 1 Functions and features...3 2 Installation...4 2.1 Addressing...4 2.2 Mechanical installation...4 2.3 Connection to

More information

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content 1. About this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning

More information

Assembly and Operating Instructions Door Control

Assembly and Operating Instructions Door Control S10 GB Assembly and Operating Instructions Door Control Important information for: Fitters Electricians Users Please forward accordingly! These instructions must be kept for future reference. Assembly

More information

Specification Voltage Limiting Device

Specification Voltage Limiting Device Engineering Specification Electrical Networks L1-CHE-SPE-152 Specification Voltage Limiting Device Version: 1 Issued: 20 th April 2018 Owner: Chief Engineer Approved By: Andrew Russack Head of Engineering,

More information

C9900-P208 and C9900-P209

C9900-P208 and C9900-P209 Installation and Operating instructions for C9900-P208 and C9900-P209 Power Supply Units Version: 1.5 Date: 2012-02-22 Table of contents Table of contents 1. Foreword 2 Notes on the Documentation 2 Liability

More information

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example... 7 ppendix 7.1 Wiring example...5 8 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / Januar 2017 / v.. - 101196069- / F / 2017-01-12 / E-Nr. 5813 Content 1 bout

More information

Fieldbus Independent I/O Modules 2 AI 4-20 ma, Single-Ended Manual

Fieldbus Independent I/O Modules 2 AI 4-20 ma, Single-Ended Manual Fieldbus Independent 2 AI 4-20 ma, Single-Ended 750-466 Manual Version 1.0.2 ii General Copyright 2006 by WAGO Kontakttechnik GmbH & Co. KG All rights reserved. WAGO Kontakttechnik GmbH & Co. KG Hansastraße

More information

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date: Installation- and Operating instructions for CU8880-0010 Ethernet Controller with USB Input Version: 1.4 Date: 2018-04-12 Table of contents Table of contents 1. 2. 3. 4. 5. General instructions 2 Notes

More information

Product manual plug, sockets and coupler 16 A.- Z0251

Product manual plug, sockets and coupler 16 A.- Z0251 Product manual plug, sockets and coupler 16 A.- Z0251 INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these

More information

Accessories for stand-alone gird inverter SMART LOAD 6000

Accessories for stand-alone gird inverter SMART LOAD 6000 Accessories for stand-alone gird inverter SMART LOAD 6000 Technical Description SL6000-TEN081820 98-2001320 Version 2.0 EN Table of Contents Table of Contents 1 Notes on this Manual..............................

More information