1 Software Update Release Notes Important Notes: To ensure proper functionality, you should use the most current version of display software, Apex desktop software, or preferred partner desktop software. Please reference software versions at the end of this document. IF YOU DO NOT UPDATE BOTH THE DISPLAY AND DESKTOP SOFTWARE VERSIONS, DATA LOSS COULD OCCUR WHEN UNLOADING DATA. StellarSupport posts the latest versions of operator manuals available and includes additional information concerning changes in Software Update Please see the following site to review and download your latest manual: North America: Europe: and choose your respective country. Go to GreenStar 2 and find your manual under product information. Documentation Setup and Settings Change With this software update the documentation setup and settings will now be saved by Implement Type and Name. Previously, this information was saved by a Field/Task association. Upgrading to APEX 2.6 will be required to view information as older versions of APEX will not be compatible with your 2600 information after updating to this newest version of display software. Therefore, if at any time you choose to back date your software after updating; returning to a previous version of APEX will also be necessary. It is recommended that you write down your settings such as offsets, COM Port settings if applicable, and other associated set up data before updating. If you are not using APEX as your Desktop Software Solution, ensure your software s current EIC is compatible with this software update (version 2.6). Contact your software provider for more information before updating your display. As a reminder, since all data is stored directly in the 1800 display, before performing any update it is recommended to back up your data to protect the information in the event of an error during the update process. Activations are non-transferrable in the event of lost, stolen, or destroyed equipment. It is recommended to insure your display at full value, including activations. Customer Contact Center Information GreenStar@JohnDeere.com North America: SUPPORT GRN-STAR ( ) ACTIVATIONS: Australia: New Zealand: Copyright Deere & Company Release Notice These are the Software Update Release Notes for the GreenStar TM Displays and Pro Modules for the GreenStar 2 (GS2) 2600 display. Apex Farm Management Software Release Notes can be found on StellarSupport.com.

2 Software Update Release Notes Summary Resolved Items Displays - GreenStar and Documentation Implement Width Adjustment Sugar Cane Harvester 1 Row Now Supported Field Peas Can Now be Chosen as a Crop Type Recording Concern Fixed for Overlap Control and Side Mount Moisture Sensors Documentation Setup Information Retention Prescription Rate Appearing Blank with Recording Off GreenStar Implement Width Adjustment Guidance Vehicles Intermittently Turn from Path with Adaptive Curves Crop Solutions - GreenStar Rate Controller Known Issues Service ADVISOR Can Program Multiple GreenStar Rate Controllers GreenStar Rate Controller NH3 Job Summaries and GS2 Display Totals are Corrected Swath Control Pro Swath Control Re-enables Automatically Inside 4.50 Condition Swath Control Percent Overlap Increased to 125% Displays - GreenStar Error 44 Occurrences Headland Boundary Boundary Recording Error Documentation - GreenStar Variety Locator Performance with Multiple Varieties Documented GreenStar DN345 Drawn Dry Box Spreader Compatibility Issue Swath Control Pro on/off check box not available when adaptive curve recording is paused 1

3 Crop Solutions GreenStar Rate Controller GS2 Status Error Operators Manual Has Incorrect Units for NH3 GRC does not retain PWM/PWM Close Settings when Software is Updated Swath Control Pro Informational Items Displays - GS Swath Control Secondary Operation Sections Commanded To Off Memory Usage Percentage Will Not Update From 0% (1800 only) Swath Control Background Map Resets ISO Virtual Terminal Update Surface Water Pro Plus Automation Turning Activations ON/OFF Text on Buttons Additional Languages GS Documentation Receivers - StarFire Individual Row Documentation is Now Possible More Possibilities for Back Ground Maps Global Prescription Limitation Check For Reflected Antenna Power Guidance Shift Track Accumulator Heading Indicator Arrow Crop Solutions - GS Rate Controller GreenStar 2 Rate Controller Name is Changing to GreenStar Rate Controller Liquid Manure Compatibility Implement Switch Requirement Changes Implement Switch Wording Changes GreenStar Rate Controller Predefined Rate Changes GreenStar Rate Controller Manual Rate Changes GreenStar Rate Controller New Rate based on Flow Calibrate Flow Meter Test Changes Configuration Test Changes All Sections Enabled After Flow Meter and Pressure Sensor Test GreenStar Rate Controller Speed Requirement Changes NH3 Energize System Test Changes Minimum Flow Rate Removed for NH3 Swath Control Pro Swath Control Diagnostic Readings Information added to the GS2 Basics OM 2

4 Software Update Release Notes Displays GreenStar Resolved Items Implement Width Implement width can now be entered in 0.01 increments instead of 0.1 increments for Metric and Imperial units to allow for increased precision. Sugar Cane Harvester 1 Row Header Now Supported The lowest number of rows that can be selected is 1 row instead of 4 rows. Known Issues Error 44 Occurrences Error 44 is notification that at least 1 byte of data did not load correctly either from the internet to your card or from your card to the display. Software update SU , July 2009, provided enhancements to minimize the error 44 event from happening. If you are updating from an older version of software 2.3, 2.2, etc. there is a slightly higher chance of an error 44 event. If this occurs, contact your John Deere Dealer for reprogramming. Headland Boundary If a Headland Boundary is created by the Top and Bottom Offset method, then after the display is turned off and on, the method will show as Driven. The Headland Boundary position is unaffected. Boundary Recording Error If boundary recording is initiated and then the machine rolls back slightly before moving forward, the display interprets the machine travel direction as reverse for a short time. Boundary points may be recorded in the wrong location and will be represented on the display as a pie piece cut out of the boundary. It is recommended to start the machine moving forward prior to pressing the Start Boundary Recording button to avoid this concern. Informational Items ISO Virtual Terminal Update Auxiliary Control - This update contains programming to allow connection to the newest ISO virtual terminal standard, VT3. If you have currently been using auxiliary control with an implement that required an earlier standard, VT2, you will need to update your VT software on the implement to VT3 standard to further use auxiliary control (e.g. Joysticks). Contact your implement vendor for this update. If an implement update is not possible and you want to proceed with Auxiliary Control, it is recommended to not update your display until your implement vendor can provide the necessary update. Surface Water Pro Plus Automation -- This software update will enable Surface Water Pro Plus scraper control to be automated by the igrade controller and GPS elevation data. (NA/AU/NZ Only) 3

5 Turning Activations ON/OFF Demo activations and normal activations can now be turned ON and OFF with check boxes on the GreenStar activations page. Un-checking an activation will hide all buttons associated with that feature. Demo Activations will not be turned OFF by default, with the exception of AutoTrac. Text on Buttons Text was added to the Softkey buttons within the GreenStar application and on the Cancel and Accept buttons. Additional Languages Greek, Icelandic, Serbian, and Slovenian can now be selected as the display language to support controllers such as the StarFire However, after selecting these languages some of the text within the display will remain in English. GreenStar Documentation Resolved Items Field Peas Available Field peas are now an available crop choice for documentation. Overlap Control and Side Mount Moisture Sensor It was previously recommended to not use Overlap Control if a side mount moisture sensor was installed and recording concerns were being seen. This has been resolved with this update. Documentation Setup Information Retention Documentation Information Setup is now saved by implement name instead of by farm and field. As an example, after connecting to and setting up a planter with seed type, variety, etc., as long as the implement name remains the same, all documentation setup information is retained when changing the farm and/or field name. Prescription Rate Appears Blank with Recording Off This item has been resolved with this update. Prescription rate will now be populated when recording is off. Informational Items Individual Row Documentation With this update it will now be possible to document individual planter rows and record up to six varieties. More Possibilities for Background Maps With this update it will now be possible to have a choice of several different options for background maps. APEX 2.6 will also be required. As a few examples you will be able to use soil maps, management zones, elevation maps, or variety maps from planting as a background map during harvest. NOTE: It is possible that when loading the background map to the display it may take from seconds to complete. Global Prescription Limitation It is recommended to have no more than 120 global prescriptions loaded on the data card at one time. Known Issues 4

6 Variety Locator Performance with Multiple Varieties Documented -- With this software update it will now be possible to document up to six varieties by individual row. Since there is only one mass flow and moisture sensor on a combine, variety locator uses the center of the harvesting header as the reference point for choosing the variety it is going to document. Multiple varieties documented across the width of the header during a pass across the field will cause individual variety data to be invalid, frequent changing to varieties, large file sizes to be generated, as well as large amounts of the display s CPU being used and may result in slow map updating. GreenStar Resolved Items Implement Width - Implement width can now be entered in 0.01 increments instead of 0.1 increments for Metric and Imperial units to allow for increased precision. Known Issues DN345 Drawn Dry Box Spreader Compatibility Issue If using the GS display to control a DN345 drawn dry box spreader and the operator changes the spread width on the DN345 controller page, the Implement Width setting for the mapping in the GreenStar application does not update automatically. The operator will need to cycle power with the key switch for the Mapping Implement width to update. Swath Control Pro on/off check box not available when adaptive curve recording is paused -- The Swath Control Pro on/off button is not available on the GS GreenStar Run Page when adaptive curve recording is paused. If Swath Control Pro needs to be shut off, the operator will need to un-pause the adaptive curve recording. Receivers StarFire Receivers Informational Items Check for Reflected Antenna Power A check is now included to look at reflected power when a RTK radio is attached. If an improper antenna is connected an error message will be displayed. The 900 MHz radio requires antenna PF The 450 MHz radio requires PF Guidance Informational Items Shift Track Accumulator With this update a shift track accumulator has been installed. The total distance and direction of guidance line shifts can now be displayed. Vehicle Heading Arrow A vehicle heading arrow is included with this update. When the heading is less than 0.5 degrees error, a green arrow is displayed in front of the machine icon; when greater than 0.5 degrees, the arrow turns yellow in color. A heading error indicator dial is available to help the operator to manage overall system performance. This indicator is found in the guidance settings pages and may be added to home pages. 5

7 Resolved Items Vehicles Intermittently Turn from Path with Adaptive Curves -- An issue with adaptive curves was resolved that had resulted in the vehicle intermittently turning away from the path. All adaptive curve users should update their display to this version of software. Crop Solutions GreenStar Rate Controller (Does Not Affect Europe) Resolved Items Service ADVISOR can program multiple GreenStar Rate Controllers Service ADVISOR can now update multiple GreenStar Rate Controllers at the same time. Service ADVISOR will begin updating the GreenStar Rate Controllers one at a time, and when finished updating each controller notification will be given that programming is complete. Previously Service ADVISOR required one single GreenStar Rate Controller to be on the CAN Bus at any given time to update software. GreenStar Rate Controller NH3 Job Summaries and GS2 Display Totals are Corrected The Actual Nitrogen Check Box on the Rates Tab will determine the units that are referenced for the totals in the GS2 Display and the GreenStar Rate controller job summaries. Check this box for an actual N unit, for example lb N/ac. Uncheck this box for a NH3 unit, for example lb NH3/ac. Known Issues GS2 Status Error - A GS2 Status Error will occur if the GS2 Display and GreenStar Rate Controller(s) are updated to the software update and then the GS2 Display is backdated to a previous version of software. A continuous GS2 Status Error will occur until the GreenStar Rate Controller(s) is physically unplugged (power removed) and plugged back in, or a vehicle restart. Operators Manual Has Incorrect Units For NH3 The metric and imperial units are incorrect for the NH3 rates based on mass per unit of area in the GreenStar Rate Controller Operator s Manual. The correct units are listed below. Kg N/ha or kg NH3/ha (Metric Units) Lb N/ac or lb NH3/ac (Imperial Units) GRC does not retain PWM/PWM Close Settings when Software is Updated --The GRC PWM/PWM Close settings coil frequency, high limit, and low limit will not be retained when the Rate 6

8 Controller is updated from 3.10F to 3.20N software. These settings will revert back to the default numbers. The control valve calibration number will be retained. It is recommended that customers using the Rate Controller with a PWM/PWM Close control valve document their below PWM/PWM Close Settings. The Rate Controller will not function without a PWM Hi Limit number, so the settings will have to be updated before the system will function. Defaults Informational Items GreenStar 2 Rate Controller Name is changing to GreenStar Rate Controller--The GreenStar Rate Controller will no longer be called the GreenStar 2 Rate Controller. The number 2 has been dropped from the name to have consistency with future compatibility. There will be a transition period where you could see both names while we work to make the required name changes. Liquid Manure Compatibility - The GreenStar Rate Controller software has been enhanced to be compatible with liquid manure applications including dragline and tank systems. System components need to meet the GreenStar Rate Controller component compatibility that is found in the Ag Sales Manual or the latest GreenStar Rate Controller Operators Manual which is located on StellarSupport.com. The Implement Type of Liquid Fert Tool should be used for manure applications in the GreenStar Rate Controller setup. o GreenStar Rate Controller liquid manure applications without a Control Valve need to select None in the Control Valve Type drop down. o When the operator has None selected as the Control Valve type indicating they cannot stop flow, Swath Control Pro is disabled. This ensures that the volume of manure applied is correct, however the acres applied will include all areas overlapped and can be slightly higher than the actual field size. o For manure applications using a dragline (does not have tank) ensure the tank volume is set to zero. This will remove the tank icons and tank level warnings. The tank volume will default to 1000 gallons. o For manure applications using a Krohne Flowmeter, ensure the pulses/gallon are set to 2 or higher. Please see the Krohne Operators Manual for further detail. 7

9 Implement Switch Requirement Changes For this software update an implement switch will be optional for Liquid Fert and required for NH3 and Planter implement types. In previous software, an implement switch was required for Liquid Fert, NH3 and Planter Implement Types. Implement Switch Wording Changes With this software update the wording has changed as follows. Previous Software New Software GreenStar Rate Controller Predefined Rate Changes The letters located on the top left corner of each Rate button (Rate1/Rate2/Rate3) represent the short-cut buttons that are available when using a Display Control. GreenStar Rate Controller Manual Rate Changes The rate previously named Manual has been changed to more accurately represent the volume or mass per unit of area based on the operator defined units. There is also a plus and minus button on each side of the rate input box for easy on the go adjustments. Implement Type US Units Metric Units Imperial Units Liquid Fertilizer gal/ac L/ha I Gal/ac Sprayer gal/ac L/ha I Gal/ac NH3 lb N/ac or lb NH3/ac kg N/ha or kg NH3/ha lb N/ac or lb NH3/ac 8

10 GreenStar Rate Controller New Rate Based On Flow There is a new rate option in the rate drop down menu for a rate based on flow. There is also a plus and minus button on each side of the rate input box for easy on the go adjustments. Implement Type US Units Metric Units Imperial Units Liquid Fertilizer gal/min L/min I Gal/min Sprayer gal/min L/min I Gal/min NH3 gal/min L/min I Gal/min Calibrate Flow Meter Test Changes There are now two Calibrate Flow Meter tests for the GreenStar Rate Controller o o Calibrate Flow Meter Catch This test allows the operator to catch product and enter the exact amount caught to calibrate the flowmeter. This test is available for sprayers and liquid fertilizer applications; it is not available for NH3 applications. The Calibrate Flowmeter Catch Test will function just like the Calibrate Flowmeter Test did prior to this software update. Calibrate Flow Meter Applied This test allows the operator to apply a known amount of product and enter the known amount to calibrate the flowmeter. This test is available for sprayers, liquid fertilizer, and NH3 applications. Configuration Test Changes - When an operator completes the Configuration Test, the flow displayed in the test screen will be utilizing the operator defined rate smoothing percentage. The rate smoothing percentage can be 3-15% (default is 3) and is setup on the GreenStar Rate Controller Rates Tab. All Sections Enabled After Completing a Flowmeter and Pressure Sensor Calibration Test - When an operator completes a Flowmeter and Pressure Sensor Calibration Test, the system will automatically re-enable all sections. In previous software, the sections that the operator disabled during the Flowmeter and Pressure Sensor Calibration test would remain disabled until the operator manually re-enabled them. GreenStar Rate Controller Speed Requirement Changes The GreenStar Rate controller now requires a vehicle speed greater than 0.5 km/h ( mph) for all the implement types except planting and seeding implement types. In previous software, the GreenStar Rate Controller required a vehicle speed greater than 1 km/h (0.62 mph) for all implement types except planting and seeding. NOTE: GreenStar Rate Controller requires a vehicle speed greater than 0 km/h (0mph) for planting and seeding implement types. Due to GPS drift, the GRC considers speeds of 0.3 km/h (0.19 mph) or less to be equal to 0 km/h (0 mph). NH3 Energize System Test Changes The NH3 Energize System Test will now enable (command open) for 3 seconds for Fast and Fast Close Valves and 8 seconds for Standard Control Valves. In previous software, the test would enable for 3 seconds for Standard, Fast, and Fast Close control valves. Minimum Flow Rate Removed for NH3 The Minimum Flow Rate requirement for NH3 has been removed with this software update. There is only a Minimum Flow Rate requirement for Sprayers and Liquid Fertilizer now. 9

11 Swath Control Pro (Section Control) Resolved Items Swath Control Re-Enables Automatically Inside 4.50 Mile Condition Swath Control Pro will disable itself if the machine gets 4.75 miles or farther from the field reference point. Swath Control will then re-enable automatically when the machine gets 4.5 miles or closer to the field reference point as long as the system was not disabled by the user. In previous software, the machine would not automatically re-enable when the machine got 4.5 miles or closer to the field reference point, the user had to manually re-enable Swath Control Pro. For further information on how the reference point is determined please reference the Swath Control Pro section of the GS2 Basics Operator Manual. Swath Control Percent Overlap Increased to 125% - Swath Control Pro can be set from 100% to 125% to achieve increasing amounts of overlap. This will allow the operator to achieve desired results and prevent skips by creating intentional overlap. It is not recommended to utilize the Turn on and Turn off times to achieve intentional overlap as this can cause additional system complications. The overlap percentage range is 0 125%. Previously it could only be set 0-100%. NOTE: It is not recommended to utilize the Turn on and Turn off times to achieve intentional overlap; this can cause additional system complications. To achieve increasing amounts of overlap utilize the Percent Overlap between %. This will allow the operator to achieve desired results and prevent skips by creating intentional overlap. Known Issues Swath Control Secondary Operation Sections Commanded To Off If using Swath Control Pro with multiple operations at once and a Client, Farm, and Field is not selected, Swath Control will only work correctly for one of the operations. Selecting a Client, Farm, and Field will correct the issue. This issue will only affect customers operating a GreenStar Rate Controller. Memory Usage Percentage Will Not Update From 0% (1800 Only) - If the operator views the Swath Control diagnostics page on the 1800 GreenStar Display, the memory usage percentage will not update from 0%. Swath Control Background Map Resets - If the operator sets the background map to aerial or variety, then navigates to the Swath Map View, they will see Operation 0/x (x-number of operations). As soon as the operator presses the Operation Toggle Button once to navigate away from the 0/x, the background will set to either Rx if in use or to if no Rx is in use. The issue will only occur on the Swath Control Map View page and the Swath Control homepages. Operation Toggle Button 10

12 Software Versions Bold items have changed. Software Update Release Notes Version # Description Software Update N/A Key EU Key GS Display PFA GS Display PF81371 ITC 1.10 M StarFire 3000 PFA10027 PFA10027 ITC 3.70 E StarFire Receiver itc PFA10025 PFA10025 PFA10025 LCR 1.10 C StarFire 300 PF81250 PF81250 PF81250 SF 7.70 B StarFire Receiver Gen II Included in SU On Keycard On Keycard TCM 1.09 A TCM Included in SU On Keycard On Keycard ATU 1.13 A ATU PFA10029 PFA10029 PFA10029 ATU 2.14 A ATU 200 PFA10030 PFA10030 PFA10030 GRC 3.20 N GS Rate Controller PF81203 RG E Universal Row Guidance PF81368 CAT 1.10 G AutoTrac Controller PF81369 GSD 1.97 B Original GreenStar Display Included in SU PF PF isteer 1.40 A isteer 1.0 PFA10084 HMCT 1.07 C Harvest Monitor Cotton SCM Included in SU On Keycard CMFS 2.07C Cotton Mass Flow Sensor CMFS Included in SU On Keycard SMON 1.73 A Original Harvest Monitor SPFH Included in SU On Keycard On Keycard HMON 1.20 C Harvest Mon for Combine with In-Tank Moisture Included in SU On Keycard On Keycard MST 7.01 B Harvest Mon for Elevator Mount Moisture Board Included in SU AC2 11 Original Air Cart Included in SU On Keycard SMVR 1.01M SeedStar Gen II Included in SU CDOC 3.56 A Field Doc Connect On Keycard On Keycard FDOC 3.57 A Field Doc Basic On Keycard TRAC 5.06B Keycard On Keycard On Keycard ADOC 1.25 A Field Doc AirCart On Keycard PDOC 3.55 A Field Doc Planter On Keycard PDOC 6.78 A Field Doc Planter On Keycard SDOC 3.44 A Field Doc Sprayer On Keycard On Keycard HDCT 1.13 A Harvest Doc Cotton On Keycard HDSP 4.13 A Original Harvest Doc SPFH On Keycard On Keycard HDOC 1.54 A Harvest Doc Combine On Keycard On Keycard YMAP 6.61 A Combine Yield Mapping On Keycard MST 6.60 B Combine Yield Monitor (Gen I Moisture Sensor ISO 2.5v Dual CAN) On Keycard On Keycard MST 5.60 A Combine Yield Monitor (Gen I Moisture Sensor Deere 4/5 CAN) On Keycard 1.12A Lightbar Via Service Advisor YWW0D6_6.Y12 Reprogramming back to Combine Yield Mapping 3.31G GS2 Harvest Doc SPFH (controller) Via Service Advisor 40 Harvest Lab Sensor See John Deere Dealer Please visit the Software Delivery System (SDS) to view and/or update all other controllers 11

13 12

Release Notes. Important Notes:

Release Notes. Important Notes: Important Notes: Software Update 2010-1 Release Notes To ensure proper functionality, you should use the most current version of display software and Apex desktop software (2.5.x.xxx). Please reference

More information

Important Notes: Release Notes

Important Notes: Release Notes Important Notes: To ensure proper functionality, you should use the most current version of display software, Apex desktop software, or preferred partner desktop software. Please reference software versions

More information

Generation 4 Displays Software Update 18-1 Release Notes

Generation 4 Displays Software Update 18-1 Release Notes Software Update Generation 4 OS installation time: Approximately 20 minutes, with no existing data. Installation time will vary depending on the amount of existing data and the software version currently

More information

Generation 4 CommandCenter

Generation 4 CommandCenter Important Notes: When installing this software version Generation 4 OS 8.12.2500-17 the update may spend up to 25 minutes at the same percentage level (such as 82%) in the Installing Software stage. This

More information

Activations. Set date and time prior to entering Activation codes to ensure the Activations will be acknowledged. Data Transfer

Activations. Set date and time prior to entering Activation codes to ensure the Activations will be acknowledged. Data Transfer Delivery Instructions Activations Set date and time prior to entering Activation codes to ensure the Activations will be acknowledged. Data Transfer Apex version 3.2 or newer is required to transfer data

More information

Online - Display and CommandARM TM Simulator. Help Guide

Online - Display and CommandARM TM Simulator. Help Guide Online - Display and CommandARM TM Simulator GS2 1800 Display GS3 CommandCenter TM Display GS3 2630 Display Generation 4 CommandCenter TM Display Last Updated: March 2016 Applies to Online Simulator Version:

More information

Generation 4 CommandCenter

Generation 4 CommandCenter Important Notes: When installing to this software version Generation 4 OS 8.11.2456-13 the update may spend up to 25 minutes at the same percentage level (such as 82%) in the Installing Software stage.

More information

Online - Display and CommandARM TM Simulator. Help Guide

Online - Display and CommandARM TM Simulator. Help Guide Online - Display and CommandARM TM Simulator Help Guide GS2 1800 Display GS3 CommandCenter TM Display GS3 2630 Display Generation 4 CommandCenter TM Display Last Updated: May 2016 Applies to Online Simulator

More information

Generation 4 Displays Software Update Release Notes

Generation 4 Displays Software Update Release Notes Software Update Generation 4 OS installation time: Approximately 40 minutes, with no existing data. Installation time will vary depending on the amount of existing data and the software version currently

More information

Display and CommandARM TM Simulator Help Guide

Display and CommandARM TM Simulator Help Guide Display and CommandARM TM Simulator Help Guide GS2 1800 Display GS3 CommandCenter TM Display GS3 2630 Display Generation 4 CommandCenter TM Display Last Updated: April 2014 Applies to Simulator Version:

More information

Generation 4 Displays Software Update Release Notes

Generation 4 Displays Software Update Release Notes Software Update Generation 4 OS installation time: Approximately 40 minutes, with no existing data. Installation time will vary depending on the amount of existing data and the software version currently

More information

Generation 4 Displays Software Update 17-2 Release Notes

Generation 4 Displays Software Update 17-2 Release Notes Software Update Generation 4 OS installation time: Approximately 40 minutes, with no existing data. Installation time will vary depending on the amount of existing data and the software version currently

More information

Generation 4 Displays

Generation 4 Displays Software Update Generation 4 OS installation time: Approximately 20 minutes, with no existing data. Installation time will vary depending on the amount of existing data and the software version currently

More information

SOFTWARE OPERATING GUIDE

SOFTWARE OPERATING GUIDE SOFTWARE OPERATING GUIDE Software Version 27.* IntelliView IV Sprayer As Applied Precision Farming E-Notes Part number 47377096 1st edition English April 2012 Contents 1 GENERAL Introduction.................................................................................

More information

Offline - Display and CommandARM TM Simulator. Help Guide

Offline - Display and CommandARM TM Simulator. Help Guide Offline - Display and CommandARM TM Simulator Help Guide GS2 1800 Display GS3 CommandCenter TM Display GS3 2630 Display Generation 4 CommandCenter TM Display Last Updated: July 2016 Applies to Offline

More information

Offline - Display and CommandARM TM Simulator. Help Guide

Offline - Display and CommandARM TM Simulator. Help Guide Offline - Display and CommandARM TM Simulator Help Guide GS2 1800 Display GS3 CommandCenter TM Display GS3 2630 Display Generation 4 CommandCenter TM Display Last Updated: June 2016 Applies to Offline

More information

Copyright Deere & Company. All Rights Reserved. THIS MATERIAL IS THE PROPERTY OF DEERE & COMPANY. ALL USE AND/OR REPRODUCTION NOT

Copyright Deere & Company. All Rights Reserved. THIS MATERIAL IS THE PROPERTY OF DEERE & COMPANY. ALL USE AND/OR REPRODUCTION NOT Copyright 2006-2011 Deere & Company. All Rights Reserved. THIS MATERIAL IS THE PROPERTY OF DEERE & COMPANY. ALL USE AND/OR REPRODUCTION NOT SPECIFICALLY AUTHORIZED BY DEERE & COMPANY IS PROHIBITED. This

More information

SeedStar 4 Planter Quick Reference Guide

SeedStar 4 Planter Quick Reference Guide SeedStar 4 Planter Quick Reference Guide CAUTION: Review, understand, and follow all procedures and safety messages in the operator's manual. This guide is not a replacement for the operator's manual.

More information

PF3000 Pro Application Rate Mode - Menu Tree for Direct Drive of Rawson Accu-Rate on a planter March 2002

PF3000 Pro Application Rate Mode - Menu Tree for Direct Drive of Rawson Accu-Rate on a planter March 2002 PF3000 Pro Application Rate Mode - Menu Tree for Direct Drive of Rawson Accu-Rate on a planter March 2002 Menu Key FIELD LOAD SHOW MAP OPTIONS CAL SETUP DIAG Press Menu Key to switch between Main Menu

More information

Task Controller Setup Manual

Task Controller Setup Manual Task Controller Setup Manual P002463 Last Update: 1/17/2017 Read and follow this operating instructions. Keep this operating instructions for future reference. 1 2 Table of Contents 1 Task Controller Setup

More information

Available Map Views & Dash View Screen

Available Map Views & Dash View Screen Singulation: Displays meter performance. Identifies the percentage of seeds properly singulated by your meters. Contributing factors to this value include: Speed, Good Ride, Seed Size, Seed Shape, Meter

More information

Generation 4 Displays Software Update 18-1 Release Notes

Generation 4 Displays Software Update 18-1 Release Notes Compatibility Notes This is the compatible equipment approved with the Software Update 18-1 release, and is subject to change with newer software updates. To ensure complete and proper compatibility, the

More information

AFS Pro 300 AFS Pro 700 Task Controller. SOFTWARE OPERATING GUIDE Software Version 30.*

AFS Pro 300 AFS Pro 700 Task Controller. SOFTWARE OPERATING GUIDE Software Version 30.* AFS Pro 300 AFS Pro 700 Task Controller SOFTWARE OPERATING GUIDE Software Version 30.* Part number 47832877 1 st edition English March 2015 Contents 1 GENERAL Manual scope...............................................................................

More information

Quick Reference Card. Setting up the FmX Integrated Display with the Autopilot System

Quick Reference Card. Setting up the FmX Integrated Display with the Autopilot System Setting up the FmX Integrated Display with the Autopilot System Quick Reference Card CONNECTING THE SYSTEM Once the Autopilot system has been professionally installed, add the FmX integrated display as

More information

AFS Pro 300 AFS Pro 700 Task Controller. SOFTWARE OPERATING GUIDE Software Version 30.6.*

AFS Pro 300 AFS Pro 700 Task Controller. SOFTWARE OPERATING GUIDE Software Version 30.6.* AFS Pro 300 AFS Pro 700 Task Controller SOFTWARE OPERATING GUIDE Software Version 30.6.* Part number 47938688 1 st edition English December 2015 Contents 1 GENERAL Manual scope...............................................................................

More information

1 AutoTrac Universal 200 Setting up the Steering Wheel Correctly

1 AutoTrac Universal 200 Setting up the Steering Wheel Correctly When first installing the ATU steering unit or transferring it to a different machine (combine or another tractor), please note the following: 1) Enter the dimensions of the tractor / self propelled machine

More information

INTEGRA Version Firmware Release

INTEGRA Version Firmware Release INTEGRA Version 2.1.0 Firmware Release Ag Leader Technology is pleased to announce the release of INTEGRA firmware. Features and improvements in this version are listed below. This free upgrade is available

More information

AMS Compatibility Tool: Frequently Asked Questions. Table of Contents

AMS Compatibility Tool: Frequently Asked Questions. Table of Contents AMS Compatibility Tool: Frequently Asked Questions Table of Contents Step 1 Step 2 & Step 3 Summary Screen Printing Additional Information Updates and Email Integration & Additional Products Receiver &

More information

Automated Crop Reporting Manual. Collecting and transferring data to JohnDeereAgent

Automated Crop Reporting Manual. Collecting and transferring data to JohnDeereAgent Automated Crop Reporting Manual Collecting and transferring data to JohnDeereAgent Agents are appointed by John Deere Insurance Company of Johnston, Iowa, which issues crop insurance products through its

More information

Quick Reference Guide

Quick Reference Guide Quick Reference Guide Envizio Pro & Envizio Pro II Overview The Envizio Pro and Envizio Pro II are all-in-one field computers capable of providing product control for up to four products (with required

More information

TopCon X5 Operator's Manual

TopCon X5 Operator's Manual TopCon X5 Operator's Manual Part Number TOPCONX5-EN Rev.1.0 Copyright Topcon Precision Agriculture May, 2011 All contents in this manual are copyrighted by Topcon. All rights reserved. The information

More information

Frequently Asked Questions

Frequently Asked Questions P a g e 1 Frequently Asked Questions Contents How do I change the brightness and sound level on my display?...2 How do I change the date and time on my display?...3 Where do I find how full my memory is

More information

Quick Reference Guide for Daily use of Yield-Pro Planter

Quick Reference Guide for Daily use of Yield-Pro Planter Quick Reference Guide for Daily use of Yield-Pro Planter Caution Please Read!! Note: This guide is intended for quick reference only. For complete set-up see owners manual, quick start guides and or your

More information

Instructions for Downloading the latest Software Enhancements (Updated July 22, 2005)

Instructions for Downloading the latest Software Enhancements (Updated July 22, 2005) Instructions for Downloading the latest Software Enhancements (Updated July 22, 2005) Section 1: Downloading Software from the Website to the Computer Page 2 Section 2: Downloading Software from the Computer

More information

with the Yield Monitoring System Quick Reference Card

with the Yield Monitoring System Quick Reference Card with the Yield Monitoring System Quick Reference Card Run screen When the Yield Monitoring plugin has been activated on the FmX integrated display, the Run screen appears. c j i d e f g h Item Description

More information

RELEASE NOTES. FmX Integrated Display. Introduction. Feature change overview. Feature changes. Upgrade procedure

RELEASE NOTES. FmX Integrated Display. Introduction. Feature change overview. Feature changes. Upgrade procedure RELEASE NOTES FmX Integrated Display Introduction Feature change overview Feature changes Upgrade procedure Version 4.00 Revision A September 2010 F Agriculture Business Area Trimble Navigation Limited

More information

John Deere FarmSight. The future of farming is in your sight.

John Deere FarmSight. The future of farming is in your sight. John Deere FarmSight The future of farming is in your sight. John Deere FarmSight. Better farming is in your sight. John Deere FarmSight is a complete solution for your farm. It combines your equipment

More information

Machine compa bility. Genera on 4 Display compa bility

Machine compa bility. Genera on 4 Display compa bility Genera on 4 Display compa bility This is the compa ble equipment approved with the so ware update 19-1 release, and is subject to change with newer so ware updates. To ensure complete and proper compa

More information

GETTING STARTED GUIDE

GETTING STARTED GUIDE GETTING STARTED GUIDE Trimble Variety Tracking System Introduction Getting the most out of the Trimble Variety Tracking system Preparing for installation Calibrating the system Recording varieties during

More information

OPERATOR S GUIDE. Document revision: 1.0 Last revised: January 29, 2018

OPERATOR S GUIDE. Document revision: 1.0 Last revised: January 29, 2018 OPERATOR S GUIDE Document revision: 1.0 Last revised: January 29, 2018 Engage Zone Control Operator s Guide 2018 Intelligent Agricultural Solutions All Rights Reserved. Engage Zone Control Operator s Guide.

More information

Operating Instructions

Operating Instructions Operating Instructions for Non-Touch Terminals TRACK-Leader Version: V6.20141016 30302432-02-EN Read and follow these operating instructions. Keep these operating instructions in a safe place for later

More information

Compatibility Tool User Manual. Updated: October 3, 2013

Compatibility Tool User Manual. Updated: October 3, 2013 Compatibility Tool User Manual Updated: October 3, 2013 What is it? The AMS Compatibility Tool is a standalone tool that identifies parts, attachments and base codes required to run single or multiple

More information

Precision Farming System PF3000 Cotton Yield Monitor Operators Manual

Precision Farming System PF3000 Cotton Yield Monitor Operators Manual Precision Farming System PF3000 Cotton Yield Monitor Operators Manual PF3000 Cotton Yield Monitor General Welcome Welcome to the family. is dedicated to the development of advanced, yet practical and

More information

For use with Aeros 9040 v4.30 DynaJet Flex IC18 Sprayer v1.10

For use with Aeros 9040 v4.30 DynaJet Flex IC18 Sprayer v1.10 S M I T H C O S T A R T - U P G U I D E For use with Aeros 9040 v4.30 DynaJet Flex IC18 Sprayer v1.10 Table of Contents #1 POWER 1 #2 CONFIGURATION 1 DynaJet Flex... 1 IC18 Sprayer on Aeros 9040... 2 Preset

More information

Valley. Controls. reliable durable precise advanced responsive

Valley. Controls. reliable durable precise advanced responsive Valley Controls reliable durable precise advanced responsive Valley Control Panels Valley ICON Model Display Edge-of-Field WiFi AgSense ICON Link Key Features 10-inch Color Touchscreen Option available

More information

Valley. Controls RELIABLE DURABLE PRECISE ADVANCED RESPONSIVE

Valley. Controls RELIABLE DURABLE PRECISE ADVANCED RESPONSIVE Valley Controls RELIABLE DURABLE PRECISE ADVANCED RESPONSIVE Valley Control Panels Valley ICON Model Display Edge-of-Field WiFi AgSense ICON Link Key Features 10-inch Color Touchscreen Option available

More information

Table of Contents Data Management...1

Table of Contents Data Management...1 Table of Contents Data Management...1 3D Mapping...1 Different Types of Summary Data...4 Saving Raw Files out of SMS...7 Scaling Yield Data...8 Q: How do I format my data card for my monitor?...10 Shape

More information

John Deere Operation Center Guide

John Deere Operation Center Guide John Deere Operation Center Guide Navigating the Map: Add Equipment: Table of Contents: Creating a New Field: Drawing the Boundary: Creating a Job: Adding a Product: User Menu: Notification Center: Using

More information

EDGE User Manual Firmware Version 4.5 Ag Leader PN Rev. F

EDGE User Manual Firmware Version 4.5 Ag Leader PN Rev. F EDGE User Manual Firmware Version 4.5 Ag Leader PN 4002086 Rev. F Table of Contents General Introduction and Company Profile...1 ABOUT US...1 INNOVATION...1 COMPATIBILITY...1 QUALITY AND SUPPORT...1 WE

More information

Installation and Configuration Manual SeedStar/Graham Interface Board

Installation and Configuration Manual SeedStar/Graham Interface Board Installation and Configuration Manual SeedStar/ Interface Board Installation In order for electric drives to be controlled by a SeedStar rate controller, the RC Interface board must be connected to the

More information

Insight Cable Connections to Rawson, New Leader Mark III & Mark IV, Flexi-Coil Controllers

Insight Cable Connections to Rawson, New Leader Mark III & Mark IV, Flexi-Coil Controllers Insight Cable Connections to Rawson, New Leader Mark III & Mark IV, Flexi-Coil Controllers 4100500 Tractor Kit (A thru E) A-4000306-10 - Display Cable (10ft) B-4000307-1 - Distribution Cable C-4000379

More information

Original Greenstar and GS 2 Raven Setup

Original Greenstar and GS 2 Raven Setup Original Greenstar and GS 2 Raven Setup Raven Controller Settings needed to communicate with GreenStar System STEP #1: Setting Up Raven Controller Press the DATA MENU button. Press the 1 or 2 Arrow buttons

More information

Loup Electronics Planter Monitor LPM II. User Guide

Loup Electronics Planter Monitor LPM II. User Guide Loup Electronics Planter Monitor LPM II User Guide TABLE OF CONTENTS 1. I TRODUCTIO...4 2. LIQUID CRYSTAL DISPLAYS...8 2.1 UPPER LCD...8 2.2 LOWER LCD...9 3. OPERATI G SPECIFICATIO...10 3.1 OPERATING MODES...10

More information

*OMPFP15047* OPERATOR'S MANUAL GreenStar Display OMPFP15047 ISSUE A5 (ENGLISH) CALIFORNIA Proposition 65 Warning

*OMPFP15047* OPERATOR'S MANUAL GreenStar Display OMPFP15047 ISSUE A5 (ENGLISH) CALIFORNIA Proposition 65 Warning *DCY* GreenStar 3 2630 Display *OMPFP15047* OPERATOR'S MANUAL GreenStar 3 2630 Display OMPFP15047 ISSUE A5 (ENGLISH) CALIFORNIA Proposition 65 Warning Diesel engine exhaust and some of its constituents

More information

Valley Controls R E L I A B L E D U R A B L E P R E C I S E E A S Y - T O - U S E R E S P O N S I V E

Valley Controls R E L I A B L E D U R A B L E P R E C I S E E A S Y - T O - U S E R E S P O N S I V E Valley Controls R E L I A B L E D U R A B L E P R E C I S E E A S Y - T O - U S E R E S P O N S I V E Valley BaseStation2-SM Now with Integrated Soil Moisture Data Reliable remote irrigation management

More information

User Manual. Gateway 6.2: Map Math

User Manual. Gateway 6.2: Map Math User Manual Gateway 6.2: Map Math TerraCutta Pro User Release Version 2.0 2014 Precision Cropping Technologies Pty Ltd. No part of this publication may be reproduced, transmitted, transcribed, stored in

More information

Valley. Controls RELIABLE DURABLE PRECISE ADVANCED RESPONSIVE

Valley. Controls RELIABLE DURABLE PRECISE ADVANCED RESPONSIVE Valley Controls RELIABLE DURABLE PRECISE ADVANCED RESPONSIVE Valley Control Panels Valley ICON Model Display Remote Device WiFi Access AgSense ICON Link Key Features 10-inch Color Touchscreen Option available

More information

JOHN DEERE Mobile Farm Manager WALK AROUND GUIDE For Android devices Android 3.0 (Honeycomb) and higher

JOHN DEERE Mobile Farm Manager WALK AROUND GUIDE For Android devices Android 3.0 (Honeycomb) and higher JOHN DEERE Mobile Farm Manager WALK AROUND GUIDE For Android devices Android 3.0 (Honeycomb) and higher CLICK THE ARROW TO GET STARTED John Deere Mobile Farm Manager A mobile application that puts customer

More information

*OMPFP13946* OPERATOR'S MANUAL GreenStar Display OMPFP13946 ISSUE J3 (ENGLISH) CALIFORNIA Proposition 65 Warning

*OMPFP13946* OPERATOR'S MANUAL GreenStar Display OMPFP13946 ISSUE J3 (ENGLISH) CALIFORNIA Proposition 65 Warning *DCY* GreenStar 3 2630 Display *OMPFP13946* OPERATOR'S MANUAL GreenStar 3 2630 Display OMPFP13946 ISSUE J3 (ENGLISH) CALIFORNIA Proposition 65 Warning Diesel engine exhaust and some of its constituents

More information

Quick Reference Guide for Daily use of Yield-Pro Planter

Quick Reference Guide for Daily use of Yield-Pro Planter Quick Reference Guide for Daily use of Yield-Pro Planter Caution Please Read!! Note: This guide is intended for quick reference only. For complete set-up see owners manual, quick start guides and or your

More information

CFX-750 Menus. Starting in the Settings Menu

CFX-750 Menus. Starting in the Settings Menu Starting in the Settings Menu EZ-Pi Auto Steer Auto Steer System Type EZ-Steer/Manual Steer Ez-Pilot AutoPilot EZ-Steer/Pilot Setup EZ-Steer/Pilot Calibration Wizard Engage Options Minimum Speed Maximum

More information

MyJohnDeere.com. How to Guide. For questions, please contact your Integrated Solutions Specialist

MyJohnDeere.com. How to Guide. For questions, please contact your Integrated Solutions Specialist MyJohnDeere.com How to Guide For questions, please contact your Integrated Solutions Specialist Table of Contents John Deere Data Policy... 3 How to create a MyJohnDeere.com Account... 4 Operations Center

More information

InSight User Manual Firmware Version 8.0 Ag Leader PN Rev. H

InSight User Manual Firmware Version 8.0 Ag Leader PN Rev. H InSight User Manual Firmware Version 8.0 Ag Leader PN 2002877 Rev. H Table of Contents General Information Introduction...1 Company Profile...1 About the Display...1 Service...2 Display Uses...2 Features...2

More information

PM PLANTER MONITOR. Operator s Manual

PM PLANTER MONITOR. Operator s Manual PM300-332 - 400 PLANTER MONITOR Operator s Manual TABLE OF CONTENTS Safety Notices... 1 Introduction... 3 System Overview... 3 Specifications... 5 Major Features... 7 Performance... 7 Console/Display...

More information

SMS Basic and Advanced Version x Release Notes

SMS Basic and Advanced Version x Release Notes English SMS Basic and Advanced Version 12.50.000x Release Notes Contents: 1. Minimum System Requirements 2. Installing the Software 3. Upgrading from v12.0x to v12.5x 4. New Features 5. Bug Fixes 6. General

More information

Agxcel. AgXcel GX2. Fertilizer System Integration for Integration into TOPCON. AgXcel GX2 Dual Electric Pump GPA Specifications GX2B

Agxcel. AgXcel GX2. Fertilizer System Integration for Integration into TOPCON. AgXcel GX2 Dual Electric Pump GPA Specifications GX2B PO Box 1611 Kearney, NE 68848 877.218.1981 www.agxcel.com GX2B AgXcel GX2 Fertilizer System Integration for Integration into TOPCON AgXcel GX2 Dual Electric Pump GPA Specifications This chart represents

More information

Precision Farming System Operators Manual

Precision Farming System Operators Manual Precision Farming System Operators Manual General Welcome Welcome to the family. is dedicated to the development of advanced, yet practical and cost-effective tools for grain production. Above all, however,

More information

we can help you get there Wherever your Precision Agriculture is taking you... Service & Products for Precision Agriculture

we can help you get there Wherever your Precision Agriculture is taking you...  Service & Products for Precision Agriculture Service & Products for Precision Agriculture Wherever your Precision Agriculture is taking you... we can help you get there Providing Electronic Service, Applications, Harnessing & Interfacing for Precision

More information

IC18 NH3 JOB COMPUTER

IC18 NH3 JOB COMPUTER IC18 NH3 JOB COMPUTER U S E R Software version 1.05 M A N U A L COPYRIGHTS 2011 TeeJet Technologies. All rights reserved. No part of this document or the computer programs described in it may be reproduced,

More information

SMS Basic and Advanced Version x Release Notes. Contents:

SMS Basic and Advanced Version x Release Notes. Contents: English SMS Basic and Advanced Version 18.00.000x Release Notes Contents: 1. Minimum System Requirements 2. Installing the Software 3. Upgrading from v17.5 to v18.0 4. New Features 5. Bug Fixes 6. General

More information

ACCESSORY APPLICATIONS

ACCESSORY APPLICATIONS Depending on your particular system configuration, the widgets below may not all appear in your widget library, or may appear differently as pictured. Note: The following widgets are current as of software

More information

Valley. Controls RELIABLE DURABLE PRECISE ADVANCED RESPONSIVE

Valley. Controls RELIABLE DURABLE PRECISE ADVANCED RESPONSIVE Valley Controls RELIABLE DURABLE PRECISE ADVANCED RESPONSIVE Valley Control Panels TouchPro The TouchPro control panel gives you powerful, yet userfriendly control of your center pivots. This panel s full-color

More information

Table of Contents. CenterLine 250/IC18 Quick Start Guide Chapter 1 - Product Overview... 5 Key Functions Startup Sequence...

Table of Contents. CenterLine 250/IC18 Quick Start Guide Chapter 1 - Product Overview... 5 Key Functions Startup Sequence... with the CenterLine IC18 Job Computer 250 BBI 98-05150 R0 Table of Contents CenterLine 250/IC18 Quick Start Guide... 1 Chapter 1 - Product Overview... 5 Key Functions... 6 Startup Sequence... 6 CenterLine

More information

We will do our best to ensure that you are happy with your current system and that it is upgraded in the future to better meet your needs.

We will do our best to ensure that you are happy with your current system and that it is upgraded in the future to better meet your needs. Welcome Welcome to the Ag Leader Technology family. Ag Leader Technology is dedicated to the development of advanced, yet practical and cost-effective tools for grain production. Above all, however, we

More information

AEROS FIELD COMPUTER RELEASE NOTES RELEASE NOTES

AEROS FIELD COMPUTER RELEASE NOTES RELEASE NOTES AEROS FIELD COMPUTER Aeros v4.33 August 2018 Support for SCM Pro v4.0.33995 Supports machines with 4 wheel steering (4WS) NOTE: See document 98-01548 for the Release Notes for SCM Pro v4.0.33995 Support

More information

844-AB SPRAYER CONTROL

844-AB SPRAYER CONTROL SPRAYER CONTROL USER GUIDE MANUAL For use with software version 4.02. Copyrights 2013 TeeJet Technologies. All rights reserved. No part of this document or the computer programmes described in it may be

More information

NOTE: This is only a guide! Please consult your local dealer for detailed instructions or troubleshooting!

NOTE: This is only a guide! Please consult your local dealer for detailed instructions or troubleshooting! AGXCEL TOPCON GUIDE (READ INSTRUCTIONS COMPLETELY BEFORE BEGINNING INSTALLATION) 116 E 6TH ST KEARNEY NE 68847 NOTE: This is only a guide! Please consult your local dealer for detailed instructions or

More information

MyJohnDeere.com. How to Guide. For questions, please contact your Precision Ag Specialist. Brookings/Garretson Scott Krogstad Cell:

MyJohnDeere.com. How to Guide. For questions, please contact your Precision Ag Specialist. Brookings/Garretson Scott Krogstad Cell: MyJohnDeere.com How to Guide For questions, please contact your Precision Ag Specialist Milbank/Watertown Eric Severson Cell: 605-695-5067 Brookings/Garretson Scott Krogstad Cell: 605-868-3558 PA Manager

More information

Quick Reference Guide

Quick Reference Guide Quick Reference Guide Viper Pro Software Version 3.10 Viper Pro Do s and Don ts Do have the Viper Pro serial number and firmware revision available when calling for technical assistance. It is best if

More information

Insight Cable Connections to Mid-Tech Controllers with Datalink

Insight Cable Connections to Mid-Tech Controllers with Datalink Insight Cable Connections to Mid-Tech Controllers with Datalink 4100500 Tractor Kit (A thru E) A-4000306-10 - Display Cable (10ft) B-4000307-1 - Distribution Cable C-4000379 - Pwr Control Relay D-4000318-3

More information

SMS Basic and Advanced Version x Release Notes

SMS Basic and Advanced Version x Release Notes English SMS Basic and Advanced Version 13.00.000x Release Notes Contents: 1. Minimum System Requirements 2. Installing the Software 3. Upgrading from v12.5x/12.6x to v13.0x 4. New Features 5. Bug Fixes

More information

Glossary access code alarm anemometer auto limits base screen central control mode Gloss

Glossary access code alarm anemometer auto limits base screen central control mode Gloss access code A user assigned 3 digit code used to restrict unauthorized usage (reprogramming/control) of the controller. alarm An irrigation related "event" reported by the controller which requires operator

More information

MATRIX GUIDANCE RELEASE NOTES

MATRIX GUIDANCE RELEASE NOTES MATRIX GUIDANCE RELEASE NOTES WARNING: Prior to v4.20, consoles with an internal GNSS receiver operate the console com port at 19200 baud rate. v4.20 and later operates the console (with internal receiver)

More information

570G VOYAGER. Automatic Sprayer Control Software version 1.05

570G VOYAGER. Automatic Sprayer Control Software version 1.05 570G RADION VOYAGER 8140 U S E R M A N U A L U S E R M A N U A L Automatic Sprayer Control Software version 1.05 Copyrights 2016 TeeJet Technologies. All rights reserved. No part of this document or the

More information

GS2 Third Party Controller Harness Kit

GS2 Third Party Controller Harness Kit GS2 Third Party Controller Harness Kit (PF90363) INSTALLATION INSTRUCTIONS GS2 Third Party Controller Harness Kit PC20424 12JAN06 (ENGLISH) John Deere Ag Management Solutions PC20424 (12JAN06) COPYRIGHT

More information

UHarvest Slingshot Reports Introduction

UHarvest Slingshot Reports Introduction UHarvest Slingshot Reports Introduction UHarvest grain cart data can be saved to a Raven Slingshot account. Use Slingshot to review field reports, edit data, merge multiple job files into one report, and

More information

About This Document. Read the Operator s Manual for the following information: Theory of operation Initial setup

About This Document. Read the Operator s Manual for the following information: Theory of operation Initial setup HarvestLab PFP12488 About This Document This User Guide will help you learn how to perform common tasks with your HarvestLab. It is a supplement to the HarvestLab Operator s Manual. Read the Operator s

More information

IntelliAg Planter/Drill Control. Operator s Manual DICKEY-john Corporation

IntelliAg Planter/Drill Control. Operator s Manual DICKEY-john Corporation IntelliAg Planter/Drill Control IntelliAg Planter/Drill Control Operator s Manual Operator s Manual 2005 DICKEY-john Corporation 11001-1324 200504 System Overview... 1 Virtual Terminal (VT)... 1 Master

More information

570G VOYAGER. Automatic Sprayer Control Software Version 1.06

570G VOYAGER. Automatic Sprayer Control Software Version 1.06 570G RADION VOYAGER 8140 U S E R M A N U A L U S E R M A N U A L Automatic Sprayer Control Software Version 1.06 Copyrights 2017 TeeJet Technologies. All rights reserved. No part of this document or the

More information

OPERATION MANUAL. Yara N-Sensor

OPERATION MANUAL. Yara N-Sensor OPERATION MANUAL for the Yara N-Sensor Software release 4.1 2016 YARA International ASA Last revised: 2016-03-14 Page 1 of 55 Table of contents Table of contents... 2 Preface... 3 Safety notes... 3 1 Preface...

More information

TABLE OF CONTENTS. Safety Notices... 1

TABLE OF CONTENTS. Safety Notices... 1 TABLE OF CONTENTS Safety Notices... 1 System Overview... 3 Virtual Terminal (VT)... 3 Master Switch... 4 Working Set Master (WSMT) Module (Granular Fertilizer Control)... 4 Working Set Member (WSMB) Module

More information

Instructions for Downloading the Latest Software Enhancements for the GreenStar System

Instructions for Downloading the Latest Software Enhancements for the GreenStar System Instructions for Downloading the Latest Software Enhancements for the GreenStar System GS2 1800 Display GS2 2100 Display GS2 2600 Display GS3 2630 Display Updated July 2017 Page 1 These instructions cover

More information

Table of Contents... 1 Installing JDOffice... 2 Activating JDOffice... 3 Starting JDOffice... 4 Navigating the Startup Screen... 4 Backup/Restore the

Table of Contents... 1 Installing JDOffice... 2 Activating JDOffice... 3 Starting JDOffice... 4 Navigating the Startup Screen... 4 Backup/Restore the Table of Contents... 1 Installing JDOffice... 2 Activating JDOffice... 3 Starting JDOffice... 4 Navigating the Startup Screen... 4 Backup/Restore the Data... 5 Help with JDOffice... 6 Online Help... 6

More information

SeedSense 2017 So ware Release Notes

SeedSense 2017 So ware Release Notes SeedSense 2017 So ware Release Notes 1. System Wide Changes 1.1 Updated the opera ng system on Gen2 20/20 displays 1.2 Added a 6 item mode to the home screen 1.3 Changed the default se ng to the Display

More information

Operation Manual ISOBUS Ammonia Liquid Fertilizer Controller

Operation Manual ISOBUS Ammonia Liquid Fertilizer Controller Operation Manual ISOBUS Ammonia Liquid Fertilizer Controller Last Update: 3/1/2018 SW Version Liquid v.01.00.04.00 - ECU HW: 1.6-1.7 SW Version Liquid v.02.00.01.00 - ECU HW: 3.0-3.2 Read and follow these

More information

TABLE OF CONTENTS. General Description

TABLE OF CONTENTS. General Description General Description 1 TABLE OF CONTENTS General Description 1 Technical Specifications 1 Disclaimer 1 Installation 2 Parts List 2 Parts Pictorial 2 Mounting & Installation 2 Connections 3 Available connections

More information

Owner s Manual. Model 6672A. 600 Series ipad Conversion Kit 6672A-16 1/17

Owner s Manual. Model 6672A. 600 Series ipad Conversion Kit 6672A-16 1/17 Owner s Manual Model 6672A 600 Series ipad Conversion Kit 6672A-16 1/17 Harvest Tec 6672A Table of Contents Page Introduction 3 Installation of Bluetooth Receiver 3-6 Large Square Baler Power Cable and

More information

SMS Basic and Advanced Version x Release Notes. Contents:

SMS Basic and Advanced Version x Release Notes. Contents: English SMS Basic and Advanced Version 17.50.000x Release Notes Contents: 1. Minimum System Requirements 2. Installing the Software 3. Upgrading from v17.2 to v17.5 4. New Features 5. Bug Fixes 6. General

More information

Legacy 6000 MID-TECH ESC. RMS-Office User Guide. Roadway Management S Y S T E M

Legacy 6000 MID-TECH ESC. RMS-Office User Guide. Roadway Management S Y S T E M Legacy 6000 MID-TECH ESC RMS-Office User Guide Roadway Management S Y S T E M TM 98-05065 Roadway Management S Y S T E M TM RMS-Office USER GUIDE PN - 98-05065 RO Chapter 1 - RMS Office Introduction...

More information

Operating Instructions

Operating Instructions Operating Instructions for Touch Terminals ISOBUS-TC Version: V2.20170221 30302436a-02-EN Read and follow these operating instructions. Keep these operating instructions in a safe place for later reference.