1 Ethernet Remote I/O Modules OMEET7000/ OMEPET7000 Series U MultiFunction Web Based Ethernet I/O Modules Models Available For Thermocouple, RTD, Analog Voltage and Current Input U BuiltIn Web Server for Remote Configuration and I/O Monitoring/Control U Web HMI U Communications Security U Supports Modbus TCP and UDP Protocols U OMEPET7000 Series Features PoE (PoweroverEthernet) The OMEET7000/OMEPET7000 Series, a webbased Ethernet I/O module, features a builtin web server which allows configuration, I/O monitoring and I/O control by simply using a regular web browser. Remote control is as easy as browsing the Internet. With the web HMI function, programming or HTML skills are not required; creating dynamic and attractive web pages for I/O monitoring and I/O control is easy. The OMEET7000/OMEPET7000 Series offers easy and safe access for users at any time, from any location. In addition, the OMEET7000/OMEPET7000 Series also supports Modbus TCP protocol that makes perfect integration to SCADA software. OMEPET7000 features PoE where not only data but also power is carried through an Ethernet cable. This feature makes installation of OMEPET7000 easy. No more unnecessary wires; only an ethernet cable that takes care of everything in the field. Features OMEPET7000 OMEET7002 shown smaller than actual size.. Power over Ethernet (PoE) The OMEPET7000 series module can be powered by an IEEE802.3af compliant PoE switch. Both data and power can be carried by an Ethernet cable eliminating the need for additional wiring and power supply. Applications Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote Diagnosis, Testing Equipment. OMEPET Builtin Web Server Each OMEET7000/OMEPET7000 module has a Builtin web server that allows the users to easily configure, monitor and control the module from a remote location using a regular web browser. SM Extended Warranty Program OMEGACARE SM extended warranty program is available for this series. Ask your sales representative for full details when placing an order. OMEGACARE SM covers parts, labor and equivalent loaners.

2 3. Web HMI The Web HMI function allows the users to create dynamic and attractive web pages to monitor and control the I/O points. Users can upload specific I/O layout pictures (bmp, jpg, gif format) and define a description for each I/O point. No HTML or Java skills are needed to create the web pages. Communication Watchdog is a software function to monitor the communication between the host and the OMEET7000/OMEPET7000 module. The timeout of the communication Watchdog is programmable, when the OMEET7000/OMEPET7000 doesn t receive commands from the host for a while, the watchdog forces the AO/DO to preprogrammed Safe Value to prevent unpredicatable damage of the connected devices. 4. Communication Security Account and password are needed when logging into the OMEET7000 web server. An IP address filter is also included, which can be used to allow or deny connections with specific IP addresses. 5. Support for both Modbus TCP and Modbus UDP Protocols The Modbus TCP, Modbus UDP slave function on the Ethernet port can be used to provide data to remote SCADA software. A free MODBUS software development toolkit is included on the utility software CD that is supplied with the OMEET7000/ OMEPET7000 Series modules. 6. Builtin I/O Various I/O components are mixed with multiple in a single module, which provides the most cost effective I/O usage and enhances performance of the I/O operations. 7. Dual Watchdog The Dual Watchdog consists of a module Watchdog and a communication Watchdog. The action of AO/DO are also associated with the Dual Watchdog. Module Watchdog is a Builtin hardware circuit to monitor the operation of the module and will reset the CPU if a failure occurs in the hardware or the software. Then the poweron value of AO/DO will be loaded. 8. Poweron Value and Safe Value Besides setting by the set AO/DO commands, the AO/DO can be set under two other conditions. Poweron Value: The Poweron Value is loaded into the AO/DO under 3 conditions: Poweron, reset by Module Watchdog, reset by reset command. Safe Value: When the Communication Watchdog is enabled and a Communication Watchdog timeout occurs, the safe value is loaded into the AO/DO.. I/O Pair Connection This function is used to create a AI/DI to AO/DO pair through the Ethernet. Once the configuration is completed, the OMEET7000/OMEPET7000 module can poll the status of remote AI/DI devices and then use the Modbus TCP protocol to continuously write to local AO/DO in the background. 0. Highly Reliable Under Harsh Environments Wide Operating Temperature Range: 25 to 75 C (3 to 67 F) Storage Temperature: 30 to 80 C ( to 76 F) Humidity 0 to 0% RH (noncondensing) 4.8 (.6).0 (.37) Dimensions: mm (inch) 0. (0.42) 3.7 (.25).0 (4.84) 0.2 (3.8) 0. (0.42) 32.3 (.27) 5.2 (2.33) 72.0 (2.83).4 (.4) 3.7 (.24) 8.0 (0.3) Top View Front View Left Side View Right Side View Rear View Bottom View 2

3 OMEET7000 Series OMEPET7000 Series Analog Input Models Model No. OMEET705 OMEPET705 OMEET707 OMEPET707 OMEET7070 OMEPET7070 OMEET708Z OMEPET708Z OMEET70Z OMEPET70Z AI Channel Voltage and Current Input Sensor Input Channel Type 7 8 0/ ±50 mv, ±500 mv, ± V, ±5 V, ±0 V, ±20 ma, 0 to 20 ma, 4 to 20 ma ±50 mv, ±500 mv, ± V, ±5 V, ±0 V, ±20 ma, 0 to 20 ma, 4 to 20 ma ±5 mv, ±50 mv, ±00 mv, ±500 mv, ± V, ±2.5 V ±20 ma, 0 to 20 ma, 4 to 20 ma ±5 mv, ±50 mv, ±00 mv, ±50 mv, ±500 mv, ± V, ±5 V, ±0 V ±20 ma, 0 to 20 ma, 4 to 20 ma RTD: Pt00, Pt000, Ni20, Cu00, Cu000 4 DO / Open collector Thermocouple: J, K, T, E, R, S, B, N, C, L, M, and LDIN4370 Thermocouple: J, K, T, E, R, S, B, N, C, L, M, and LDIN Open collector Open collector Note: Use OMEET708Z/OMEPET708Z and OMEET70Z/OMEPET70Z for extremely accurate thermocouple measurement. 3

4 Multifunction I/O Model No. OMEET7002 OMEPET7002 Channel 3 AI AO DI/Counter DO Voltage and Current Input ±50 mv, ±500 mv, ± V, ±5 V, ±0 V, 0 ma to 20 ma, ±20 ma, 4 to 20 ma Sensor Input Channel Voltage and Current Output Channel Contact Channel Type 6 Wet (sink, source) 3 Power relay (form A) OMEET7026 OMEPET ±50 mv, ±500 mv, ± V, ± 5 V, ±0 V, 0 to 20 ma, ±20 ma, 4 to 20 ma 2 0 to 5 V, ±5 V, 0 to 0 V, ±0 V, 0 to 20 ma, 4 to 20 ma 2 Dry (source), wet (sink, source) 2 Open collector (sink) Digital I/O DI/Counter DO Model No. OMEET7042 OMEPET7042 Channel Contact / Channel Type / 6 Open collector Maximum Load 25 C 00 ma/channel OMEET7044 OMEPET Wet, source 8 Open collector 300 ma/channel OMEET7050 OMEPET Wet, source 6 Open collector 00 ma/channel OMEET705 OMEPET705 6 Wet, source OMEET7052 OMEPET Wet, source 8 Open collector 650 ma/channel OMEET7053 OMEPET Dry Relay Output and Digital Input Model No. OMEET7060 OMEPET7060 OMEET7067 OMEPET7067 Relay Output Channel Relay Type 6 Power relay 8 Power relay Form A (SPST N.O.) Form A (SPST N.O.) DI/Counter Maximum Load 25 C Channel Contact / 5.0 A/channel 6 Wet, source 5.0 A/channel 4

5 3Channel Analog Input and DIO Modules OMEET7002/OMEPET7002 U BuiltIn Web Server U Web HMI U Support for both Modbus TCP and Modbus UDP Protocols U Communication Security U Dual Watchdog U Wide Operating Temperature Range: 25 to 75 C (3 to 67 F) U I/O Pair Connection U BuiltIn I/O AI: 3 Channels with 240 Vrms Overvoltage DI/Counter: 6 Channels Power Relay: 3 Channels Applications U Building Automation U Factory Automation U Machine Automation U Remote Maintenance U Remote Diagnosis U Testing Equipment OMEPET7002 shown actual size. Voltage Input Current Input The OMEET7002/OMEPET7002 is a webbased Ethernet I/O module that features a builtin web server which allows remote configuration, I/O monitoring and I/O control simply by using a regular web browser. Remote control is as easy as browsing the Internet. In addition, the web HMI function means that programming or HTML skills are no longer required so creating dynamic and attractive web pages for I/O monitoring and I/O control purposes is easy. The OMEET7002/OMEPET7002 offers easy and safe access for users at anytime and from any location, and also supports the Modbus TCP protocol that ensures perfect integration with SCADA software. Furthermore, the OMEPET7002 features PoE, meaning that not only is data transmitted through an Ethernet cable but also power making installation of the OMEPET7002 easy. No more unnecessary wires with only an ethernet cable being required to take care of everything in the field. The OMEET7002/OMEPET7002 is a multifunction module; there are 3channel analog inputs, 6channel digital inputs and 3channel relay outputs module. It provides programmable input range on all analog inputs (±50 mv, ±500 mv, ± V, ±5 V, ±0 V, ±20 ma, 0 to 20 ma and 4 to 20 ma). Each analog input is allowed to configure an individual range and has 240 Vrms high overvoltage protection. Jumper selectable for voltage or current inputs, OMEET7002/OMEPET7002 is fully RoHScompliant and has qualification for 4 kv ESD protection as well as 2500 Vdc intramodule isolation. mv/v V mv/v V Digital Input/ Counter Power Relay Relay Output Vin Vin Vin Default JUMPER Vin Vin Default Readback as Readback as 0 0 DIxto 0K 50 Vdc OPEN DIx 0K or <4 Vdc DIx DI.COM JUMPER 0K DI.COM DIx 0K 0 to 50 Vdc OPEN or <4 Vdc DIx 0K DI.COM ma ma DI.COM RLx.COM Relay Close AC/DCRLx.COM Relay Close Readback as AC/DC RLx.NO RLx.COM Relay Close RLx.NO AC/DC w RLx.NO DIx DI.COM 0K DI.COM DIx 0K DIx 0K DIx 0K DI.COM DI.COM DI.COM RLx.COM AC/DCRLx.COM OFF State Readback as 0 AC/DC RLx.NO RLx.COM RLx.NO AC/DC RLx.NO Vin JUMPER Vin Vin JUMPER Relay Open Relay Open Relay Open 5

6 6 System Specifications Models OMEET7002 OMEPET7002 Software Builtin Web Server Web HMI I/O Pair Connection Communication Ethernet Port 0/00 basetx with Auto MDI/ MDIX PoE Protocol Modbus TCP, Modbus UDP Security ID, password and IP filter, module (0.8 seconds), Dual Watchdog communication (programmable) LED Indicators L (System Running) (Ethernet Link/Act) (Ethernet 0/00 M Speed) PoE Power 2Way Isolation Ethernet 500 Vdc I/O 2500 Vdc 2500 Vdc EMS ESD (IEC ) 4 kv contact for each terminal and 8 kv air for random point EFT (IEC ) ±4 kv for power Surge (IEC ) ±4 kv for power Power Requirements Reverse Polarity Powered from, 0 to, 2 to Terminal Block 30 Vdc 48 Vdc, IEEE Powered from PoE 802.3af, Class Consumption.7 W Mechanical Dimensions (W x L x D) 72 x x mm (2.8 x 4.8 x.4) Installation L DINrail or wall mounting Environment Operating PET7002 Temperature 25 to 75 C (3 to 67 F) Storage Temperature 30 to 80 C ( to 76 F) Humidity 0 to 0% RH, noncondensing IN 5 IN 4 IN 3 IN 2 IN IN 0 R COM R NO RL COM RL NO RL0 COM RL0 NO Pin Assignments Vin 0 in 0 Vin 0 in 0 Vin in Vin in Vin 2 in 2 Vin 2 in 2 /A 0 IN 5 IN 4 IN 3 IN 2 IN IN 0 R COM R NO RL COM RL NO RL0 COM RL0 NO 0 (R)Vs R)Vs B)GND I/O Specifications Analog Input Channels 3 (differential) ±50 mv, ±500 mv, ±V, ±5 V, Type ±0 V 0 ma to 20 ma, ±20 ma, 4 to 20 ma (jumper selectable) Individual Channel Configuration Resolution Normal Mode 6bit Fast Mode 2bit Sampling Normal Mode 0 samples/second (total) Rate Fast Mode 60 samples/second (total) Accuracy Normal Mode ±0.% Fast Mode ±0.5% or better Zero Drift ±20 μv/ C Span Drift ±25 ppm/ C Overvoltage 240 Vrms Overcurrent 50 ma maximum at 0 Vdc/Vac maximum Input Voltage 2 MΩ Impedance Current 24 Ω Common Mode Rejection 86 db minimum Normal Mode Rejection 00 db Digital Input/Counter Channels 6 Contact Wet contact / (NPN/PNP) /source On Voltage Level 0 Vdc to 50 Vdc Off Voltage Level 4 Vdc maximum Input Impedance 0 kω, 0.5W Channels 6 Maximum Count 4,24,67,285 (32bit) Counters Maximum Input Frequency 00 Hz Minimum Pulse Width 5 ms Overvoltage 50 Vdc Power Relay Channels 3 Type Power relay, Form A (SPST N.O.) Operating Voltage Range 250 Vac/30 Vdc Maximum Load Current 5.0A/channel at 25 C Operate Time 6 ms (typical) Release Time 3 ms (typical) VDE: Vdc 30,000 ops (0 ops/minute) at 75 C 5 30 Vdc 70,000 ops (0 ops/minute) at 75 C Electrical Life (Resistive Load) UL: Vac/30 Vdc 6000 ops Vac/30 Vdc 00,000 ops Mechanical Life 20,000,000 ops. at no load (300 ops./minute) L Intramodule Isolation, FieldtoLogic 3750 Vdc PET7002 Poweron Value, programmable Safe Value, programmable Model No. Description OMEET7002 3channel analog input and DIO module OMEPET7002 3channel analog input and DIO module with PoE RAI5 mm (.4") DIN rail, m (3.3') length idrnps000 DIN rail power supply, 5 to 240 Vac input, 24 Vdc output at 850 ma OMESW05 5port unmanaged ethernet switch OMESW05POE 5port POE ethernet switch (four 0/00 base TX ports with POE and one 0/00 base TX uplink port) Comes complete with wall mount bracket, quick start guide, utility software and operator s manual on CD. Ordering Example: OMEET7002 3channel analog input and DIO module and OCW OMEGACARE SM extends standard year warranty to a total of 2 years.

7 7Channel RTD Input Modules OMEET705/OMEPET705 U BuiltIn Web Server U Web HMI U Support for both Modbus TCP and Modbus UDP Protocols U Communication Security U Dual Watchdog U Wide Operating Temperature Range: 25 to 75 C (3 to 67 F) U I/O Pair Connection U BuiltIn I/O RTD Input: 7 Channels Applications U Building Automation U Factory Automation U Machine Automation U Remote Maintenance U Remote Diagnosis U Testing Equipment The OMEET705/OMEPET705 is a webbased ethernet I/O module that features a builtin web server which allows remote configuration, I/O monitoring and I/O control simply by using a regular web browser. Remote control is as easy as browsing the Internet. In addition, the web HMI function means that programming or HTML skills are no longer required so creating dynamic and attractive web pages for I/O monitoring and I/O control purposes is easy. The OMEET705/ OMEPET705 offers easy and safe access for users at anytime and from any location, and also supports the Modbus TCP protocol that ensures perfect integration with SCADA software. Furthermore, the OMEPET705 features PoE, meaning that not only is data transmitted through an ethernet cable but also power making installation of the OMEPET705 easy. No more unnecessary wires with only an Ethernet cable being required to take care of everything in the field. OMEET705 shown actual size. OMEET705/OMEPET705 is specifically designed for longdistance RTD measurement. It features automatic compensation for threewire RTD so that it can measure correctly regardless of the length of wires and provide open wire detection for RTD measurement. OMEET705/OMEPET705 offers 7, each of which could be connected with different kinds of RTD (Pt00, Pt000, Ni20, Cu00, Cu000). Also, OMEET705/OMEPET705 is fully RoHScompliant and has qualification for 4 kv ESD protection as well as 2500 Vdc intramodule isolation. Wire Connections Open Collector () CH0,, 2, 5 and 6 CH3 and CH4 2Wire of RTD RTDx 3Wire of RTD RTDx RTDx RTDx RTD3 RTD3 RTD4 RTD4 RTD3 RTD3 RTD4 RTD4 7

8 System Specifications Model No. OMEET705 OMEPET705 Software Builtin Web Server Web HMI I/O Pair Connection Communication Ethernet Port 0/00 BaseTX with Auto MDI/ MDIX PoE Protocol Modbus TCP, Modbus UDP Security ID, password and IP filter Dual Watchdog, module (0.8 seconds), communication (programmable) LED Indicators L (System Running) (Ethernet Link/Act) (Ethernet 0/00 M Speed) PoE Power 2Way Isolation Ethernet 500 Vdc I/O 2500 Vdc 2500 Vdc EMS ESD (IEC ) 4 kv contact for each terminal and 8 kv air for random point EFT (IEC ) ±4 kv for power Power Requirements Reverse Polarity Powered from Terminal Block, 0 to 30 Vdc Powered from PoE, 2 to 48 Vdc, IEEE 802.3af, class Consumption 2.0 W 2.6 W Mechanical Dimensions (W x L x D) Installation Environment Operating Temperature Storage Temperature Humidity 72 x x mm (2.8 x 4.84 x.37") DINrail or wall mounting 25 to 75 C (3 to 67 F) 30 to 80 C ( to 76 F) 0 to 0% RH, noncondensing Pin Assignments RTD Input Channels Sensor Type Wire Connections Individual Channel Configuration Resolution Sampling Rate 7 (differential) Pt00, Pt000, Ni20, Cu00, Cu000 2/3 wire 6bit Accuracy ±0.05% Zero Drift Span Drift Common Mode Rejection Normal Mode Rejection Input Impedance Open Wire Detection 3wire RTD Lead Resistance Elimination ET705 RTD4 RTD4 RTD3 RTD3 RTD2 RTD2 RTD RTD RTD0 RTD0 I/O Specifications RTD5 RTD5 2 samples/second (total) ±0.5 μv/ C ±20 μv/ C 50 db 00 db > MΩ RTD6 ET705 RTD6 N.C. L 0 (R)Vs L RTD5 RTD5 RTD6 RTD6 N.C. (R)Vs To Order Visit omega.com/omeet7000_omepet7000 for Pricing and Details Model No. Description OMEET705 7channel RTD input module OMEPET705 7channel RTD input module with PoE RAI5 mm (.4") DIN rail, m (3.3') length idrnps000 DIN rail power supply, 5 to 240 Vac input, 24 Vdc output at 850 ma OMESW05 5port unmanaged ethernet switch OMESW05POE 5port POE ethernet switch (four 0/00 base TX ports with POE and one 0/00 base TX uplink port) Comes complete with wall mount bracket, quick start guide, utility software and operator s manual on CD. Ordering Example: OMEET705 7channel analog input module and OCW OMEGACARE SM extends standard year warranty to a total of 2 years. 8

9 8Channel Analog Input and DO Modules OMEET707/OMEPET707 U BuiltIn Web Server U Web HMI U Support for both Modbus TCP and Modbus UDP Protocols U Communication Security U Dual Watchdog U Wide Operating Temperature Range: 25 to 75 C (3 to 62 F) U I/O Pair Connection U BuiltIn I/O AI: 8 Channels with 240 Vrms Overvoltage DO: 4 Channels Applications U Building Automation U Factory Automation U Machine Automation U Remote Maintenance U Remote Diagnosis U Testing Equipment The OMEET707/OMEPET707 is a webbased Ethernet I/O module that features a builtin web server which allows remote configuration, I/O monitoring and I/O control simply by using a regular web browser. Remote control is as easy as browsing the Internet. In addition, the web HMI function means that programming or HTML skills are no longer required so creating dynamic and attractive web pages for I/O monitoring and I/O control purposes is easy. The OMEET707/ OMEPET707 offers easy and safe access for users at anytime and from any location, and also supports the Modbus TCP protocol that ensures perfect integration with SCADA software. Furthermore, the OMEPET707 features PoE, meaning that not only is data transmitted through an Ethernet cable but also power making installation of the OMEPET707 easy. No more unnecessary wires with only an Ethernet cable being required to take care of everything in the field. Wire Connections Voltage Input JUMPER Current Input OMEET707 shown actual size. The OMEET707/OMEPET707 is a 6bit, 8channel differential analog input and 4channel digital ouput module that provides programmable input range on all analog (±50 mv, ±500 mv, ± V, ±5 V, ±0 V, ±20 ma, 0 to 20 ma and 4 to 20 ma) and digital output can be set as alarm output with shortcircuit protection and overload protection. Each analog channel is allowed to configure an individual range and has 240 Vrms high overvoltage protection. Modules are jumper selectable for voltage or current input. The sampling rate of OMEET707/OMEPET707 is selectable; fast mode or normal mode. OMEET707/OMEPET707 also has qualification for 4 kv ESD protection as well as 3000 Vdc intramodule isolation. JUMPER mv/v V Vin Vin Vin Vin Default ma Digital Output Readback as OFF State Readback as 0 Open Collector () 5 to 50 VDC 5 to 50 VDC

10 ET707 System Specifications Models OMEET707 OMEPET707 Software Builtin Web Server Web HMI I/O Pair Connection Communication Ethernet Port 0/00 basetx with auto MDI/ MDIX PoE Protocol Modbus TCP, Modbus UDP Security ID, password and IP filter Dual Watchdog, module (0.8 seconds), communication (programmable) LED Indicators L (System Running) (Ethernet Link/Act) (Ethernet 0/00 M Speed) PoE Power 2Way Isolation Ethernet 500 Vdc I/O 2500 Vdc 2500 Vdc EMS ESD (IEC ) 4 kv contact for each terminal and 8 kv air for random point EFT (IEC ) ±4 kv for power Power Requirements Reverse Polarity Powered from Terminal Block, 0 to 30 Vdc Powered from PoE, 2 to 48 Vdc, IEEE 802.3af, class Consumption 2.6 W 3. W Mechanical Dimensions (W x L x D) Installation Environment Operating Temperature Storage Temperature Humidity 72 x x mm (2.83 x 4.84 x.38") DINrail or wall mounting 25 to 75 C (3 to 67 F) 30 to 80 C ( to 76 F) 0 to 0% RH, noncondensing Pin Assignments I/O Specifications Analog Input Channels Type Vin6 Vin6 Vin5 Vin5 Vin4 Vin4 Vin3 Vin3 Vin2 Vin2 Vin Vin Vin0 Vin0 Vin7 Vin7 DO0 DO DO2 DO3 (R)Vs 8 (differential) ±50 mv, ±500 mv, ±V, ±5V, ±0V, ±20 ma, 0 to 20 ma, 4 to 20 ma (jumper selectable) Individual Channel Configuration Resolution Normal Mode 6bit Fast Mode 2bit Sampling Normal Mode 0 samples/second (total) Rate Fast Mode 60 samples/second (total) Accuracy Normal Mode ±0.% Fast Mode ±0.5% or better Zero Drift ±20 μv/ C Span Drift ±25 ppm/ C Overvoltage 240 Vrms Input Voltage 2 MΩ Impedance Current 25 Ω Common Mode Rejection 86 db minimum Normal Mode Rejection 00 db Digital Output Channels 4 Type Isolated open collector / (NPN/PNP) Maximum Load Current 700 ma/channel Load Voltage 5 Vdc to 50 Vdc Overvoltage 60 Vdc Overload.4 A ShortCircuit PowerOn Value, programmable Safe Value, programmable ET707 To Order Visit omega.com/omeet7000_omepet7000 for Pricing and Details 0 L Vin7 Vin7 DO0 DO DO2 DO3 (R)Vs Model No. Description OMEET707 8channel analog input and DO module OMEPET707 8channel analog input and DO module with PoE RAI5 mm (.4") DIN rail, m (3.3') length idrnps000 DIN rail power supply, 5 to 240 Vac input, 24 Vdc output at 850 ma OMESW05 5port unmanaged ethernet switch OMESW05POE 5port POE ethernet switch (four 0/00 base TX ports with POE and one 0/00 base TX uplink port) Comes complete with wall mount bracket, quick start guide, utility software and operator s manual on CD. Ordering Example: OMEET707 8channel analog input and DO module and OCW OMEGACARE SM extends standard year warranty to a total of 2 years. 0

11 0 Differential/20 SingleEnded Channel Analog Input Modules OMEET7070/OMEPET7070 U BuiltIn Web Server U Web HMI U Support for Both Modbus TCP and Modbus UDP Protocols U Communication Security U Dual Watchdog U Wide Operating Temperature Range 25 to 75 C (3 to 67 F) U I/O Pair Connection U BuiltIn I/O AI: 0 Differential/20 SingleEnded Channels with 240 Vms Overvoltage Applications U Building Automation U Factory Automation U Machine Automation U Remote Maintenance U Remote Diagnosis U Testing Equipment The OMEET7070/OMEPET7070 is a webbased Ethernet I/O module that features a builtin web server which allows remote configuration, I/O monitoring and I/O control simply by using a regular web browser. Remote control is as easy as browsing the Internet. In addition, the web HMI function means that programming or HTML skills are no longer required so creating dynamic and attractive web pages for I/O monitoring and I/O control purposes is easy. The OMEET7070/OMEPET7070 offers easy and safe access for users at anytime and from any location, and also supports the MODBUS TCP protocol that ensures perfect integration with SCADA software. Furthermore, the OMEPET7070 features PoE, meaning that not only is data transmitted through an Ethernet cable but also power making installation of the OMEPET7070 easy. No more unnecessary wires with only an Ethernet cable being required to take care of everything in the field. The OMEET7070 is a 6bit, 0channel differential or 20channel singleended analog input module that provides programmable input range on all analog (±50 mv, ±500 mv, ± V, ±5 V, ±0 V, ±20 ma, 0 to 20 ma and 4 to 20 ma). Each analog channel is allowed to configure an individual range and has 240 Vrms high overvoltage protection. Modules are jumper selectable for voltage or current input. The sampling rate of OMEET707/ OMEPET707 is selectable; fast mode or normal mode. OMEET707/OMEPET707 also has qualification for 4 kv ESD protection as well as 3000 Vdc intramodule isolation. Wire Connections mv/v V mv/v V ma Voltage Input (Differential Mode) JUMPER Voltage Input (Singleended Mode) JUMPER Vin Current Input Vin Vin Vin Vin OMEET7070 shown actual size. JUMPER Default Default SM or Shop Online at omega.com

12 ET System Specifications Models OMEET7070 OMEPET7070 Software Builtin Web Server Web HMI I/O Pair Connection Communication Ethernet Port 0/00 BaseTX with Auto MDI/MDIX PoE Protocol Modbus TCP, Modbus UDP Security ID, password and IP filter Dual Watchdog, module (0.8 seconds), communication (programmable) LED Indicators L (System Running) (Ethernet Link/Act) (Ethernet 0/00 M Speed) PoE Power 2Way Isolation Ethernet 500 Vdc I/O 2500 Vdc 2500 Vdc EMS ESD (IEC ) 4 kv contact for each terminal and 8 kv air for random point EFT (IEC ) ±4 kv for power Power Requirements Reverse Polarity Powered from Terminal Block, 0 to 30 Vdc, 2 to 48 Vdc Powered from PoE, IEEE 802.3af, class Consumption 2.6 W 3.8 W Mechanical Dimensions (W x L x D) 72 x x mm (2.83 x 4.84 x.38") Installation DINrail or wall mounting Environment Operating Temperature 25 to 75 C Storage Temperature 30 to 80 C Humidity 0 to 0% RH, noncondensing Model No. OMEET7070 OMEPET7070 RAI5 idrnps000 OMESW05 OMESW05POE Pin Assignments I/O Specifications Analog Input Channels Type Individual Channel Configuration Normal Resolution Mode Fast Mode Sampling Rate Accuracy Zero Drift Span Drift Vin6/Vin6 Overvoltage Vin6 Vin5/Vin5 Vin5 Vin4/Vin4 Normal Mode Fast Mode Normal Mode Fast Mode Differential Single Ended Input Voltage Impedance Current Common Mode Rejection Normal Mode Rejection Vin7 Vin7/Vin7 Vin8 Vin8/Vin8 Vin Vin/Vin (R)Vs 0 differential or 20 singleended*, software selectable ±50 mv, ±500 mv, ±V, ±5V, ±0V, ±20 ma, 0 to 20 ma, 4 to 20 ma (Jumper Selectable) 6bit 2bit 0 samples/second (total) 60 samples/second (total) ±0.% ±0.5% or better ±20 μv/ C ±25 ppm/ C 240 Vrms 50 Vrms 2 MΩ (differential), MΩ (singleended) 25 Ω 86 db minimum 00 db Vin4 Vin3/Vin3 Vin3 Vin2/Vin2 Vin2 ET7070 Vin/Vin Vin Vin0/Vin0 Vin0 0 L Vin7 Vin7/Vin7 Vin8 Vin8/Vin8 Vin Vin/Vin (R)Vs Description 0 differential/20 singleended channel analog input module 0 differential/20 singleended channel analog input module with PoE mm (.4") DIN rail, m (3.3') length DIN rail power supply, 5 to 240 Vac input, 24 Vdc output at 850 ma 5port unmanaged ethernet switch 5port POE ethernet switch (four 0/00 base TX ports with POE and one 0/00 base TX uplink port) * Differential mode can be used for voltage input and current input. Singleended mode can be used for voltage input only. Comes complete with wall mount bracket, quick start guide, utility software and operator s manual on CD. Ordering Example: OMEET differential/20 singleended channel analog input module and OCW OMEGACARE SM extends standard year warranty to a total of 2 years.

13 0Channel Thermocouple Input Modules with OMEDB820 Daughter Board OMEET708Z/OMEPET708Z U BuiltIn Web Server U Web HMI U Support for Both Modbus TCP and Modbus UDP Protocols U Communication Security U Dual Watchdog U Wide Operating Temperature Range: 25 to 75 C (3 to 67 F) U I/O Pair Connection U BuiltIn I/O Thermocouple Input: 0 Channels DO: 6 Channels Applications U Building Automation U Factory Automation U Machine Automation U Remote Maintenance U Remote Diagnosis U Testing Equipment OMEET708Z shown actual size. The OMEET708Z/OMEPET708Z is a webbased Ethernet I/O module that features a builtin web server which allows remote configuration, I/O monitoring and I/O control simply by using a regular web browser. Remote control is as easy as browsing the Internet. In addition, the web HMI function means that programming or HTML skills are no longer required so creating dynamic and attractive web pages for I/O monitoring and I/O control purposes is easy. The OMEET708Z/ OMEPET708Z offers easy and safe access for users at anytime and from any location, and also supports the Modbus TCP protocol that ensures perfect integration with SCADA software. Furthermore, the OMEPET708Z features PoE, meaning that not only is data transmitted through an Ethernet cable but also power making installation of the OMEPET708Z easy. No more unnecessary wires with only an Ethernet cable being required to take care of everything in the field. The OMEET708Z/OMEPET708Z is specifically designed for extremely accurate thermocouple measurement and features automatic coldjunction compensation for each channel to ensure temperature output consistency and stable temperature output in the field. Current input and voltage input are both supported. Another feature is that the ten input can be individually configured for different kinds of analog input. Open thermocouple detection and ESD/EFT/Surge protection mechanisms are also included. The six digital output can be set as alarm outputs with shortcircuit protection and overload protection. SM or Shop Online at omega.com 3

14 System Specifications Model No. OMEET708Z OMEPET708Z Software Builtin Web Server Web HMI I/O Pair Connection Communication Ethernet Port 0/00 BaseTX with Auto MDI/MDIX PoE Protocol Modbus TCP, Modbus UDP Security Dual Watchdog LED Indicators L (System Running) (Ethernet Link/Act) (Ethernet ID, password and IP filter, module (0.8 seconds), communication (programmable) 0/00 M Speed) PoE Power 2Way Isolation Ethernet 500 Vdc I/O 2500 Vdc 2500 Vdc EMS ESD (IEC ) EFT (IEC ) Power Requirements Reverse Polarity 4 kv contact for each terminal and 8 kv air for random point ±4 kv for Power Powered from Terminal Block, 0 to 30 Vdc Powered from PoE Consumption 2.0 W 3.0 W Mechanical Dimensions (W x L x D) Installation Environment Operating Temperature Storage Temperature Humidity, 2 to 48 Vdc, IEEE 802.3af, class 72 x 6 x mm (2.83 x 4.5 x.37") DINrail or wall mounting 25 to 75 C (3 to 67 F) 30 to 80 C ( to 76 F) 0 to 0% RH, noncondensing I/O Specifications Thermocouple Input Channels 0 (differential) ±5 mv, ±50 mv, ±00 mv, ±500 mv, ± V, ±2.5 V ±20 ma, 0 to 20 ma, 4 to Sensor Type 20 ma (Requires Optional External 25 Ω Resistor) Thermocouple (J, K, T, E, R, S, B, N, C, L, M, and LDIN4370) Individual Channel Configuration Resolution 6bit Sampling Rate 0 samples/second (total) Accuracy ±0.% of FSR or better Zero Drift ±0.5 μv/ C Span Drift ±25 ppm/ C Over Voltage 240 Vrms Input Impedance >300 kω Common Mode Rejection 50 db minimum Normal Mode Rejection 00 db Temperature Output Consistency Stable Temperature Output in the Field Open Wire Detection Digital Output Channels 6 Type Isolated open collector / (NPN/PNP) Max. Load Current 700 ma/channel Load Voltage 5 to 50 Vdc Overvoltage 60 Vdc Overload.4 A Shortcircuit Poweron Value, programmable Safe Value, programmable Wire Connections 25 Ω V Voltage Input (Default) CH Thermocouple Input (Default) CH CH CH Current Input CH Note: When connecting to a current source, an CHoptional external 25 Ω resistor is required. Digital Output Readback as OFF State Readback as 0 Open Collector () 5 to 50 Vdc 5 to 50 Vdc 4

15 3.5 (.24) Dimensions: mm (inch) Rear M3 Pin 3.5 Assignments OMEDB820 CON CHCH2 CH2 33 (.3) 3.5 (.55) 72.0 (2.83) CH3 3.5 (.55) CH4 OMEDB820 L (R)Vs DO5 DO4 DO2 DO3 DO DO0 64 (2.52) 58 (2.28) CH 64 (2.52) 64 (2.52) 0.8 (0.42) 5 (0.5) 2.8 (0.5) 2.8 (0.5) 2.8 (0.5) 2.8 (0.5) 2.8 (0.5) 65 (2.55) (0.42) 5 (0.5) (2.55) 5 (0.5) 0.8 (0.42) 0.8 (0.42) Top view 5 (0.5) 0.8 (0.42) 5 (0.5) 0.8 (0.42) 0. (0.4 Rear view 58 (2.28) 0.8 (0.42) (0.5) (0.42) (0.42) (0.5) 5 (0.5) 78 (3.07) 73.3 (2.88) 5 (0.5) 2.8 (0.5)(.37) 2.8 (0.5) 2.8 (0.5) 2.8 (0.5) Bottom View 2.8 (0.5) 0.8 (0.42) 5 (0.5) ( 5 (0.5) 0.8 (0.42) Left side view Model No. OMEET708Z OMEPET708Z RAI5 idrnps000 OMESW05 OMESW05POE 0 0 To Order Visit omega.com/omeet7000_omepet7000 for Pricing and Details 64 (2.52) 58 (2.28) 0.8 (0.42) (.37) 78 (2.55) CH8 (2.55) (2.88) CH83.5 CH (.55) CON 73.3 (2.88) 78 (3.07) 73.3 (2.88) 58 (2.28) CH6 65 CH7(2.55) CH765(3.07) Front view 5 (0.5) (4.56) (0.42) (0.42) (0.42) (0.5) (0 CH6 CH3 OMEET708Z Bottom view Description 0channel thermocouple input module with OMEDB820 daughter board 0channel thermocouple input module with OMEDB820 daughter board with PoE mm (.4") DIN rail, m (3.3') length DIN rail power supply, 5 to 240 Vac input, 24 Vdc output at 850 ma 5port unmanaged ethernet switch 5port POE ethernet switch (four 0/00 base TX ports with POE and one 0/00 base TX uplink port) Comes complete with wall mount bracket, quick start guide, utility software and operator s manual on CD. Ordering Example: OMEET708Z 0channel thermocouple input module with OMEDB820 daughter board and OCW OMEGACARESM extends standard year warranty to a total of 2 years. ( 3.5 (.55) (.37) (.37) (.37) CH5 CH5 58 (2.28) 64 (2.52) 64 (2.52) 64 (2.52) CH4 Top view DN8 58 (2.28) 64 (2.52) 58 (2.28) 58 (2.28) 64 (2.52) 78 OMEDB (2.52) (3.07) (.55) DIN rail(.55) mounting bracket CH0 CH0 2SCREW 58 (2.28) 6 M3 CH (4.56) OMEDB (2.28) COM OMEDB (.55) 78 (3.07) (3.07) 78 (2.88) (3.07) 73.3 (2.88) 73.3 (2.88) 72.0 (2.83) 6 Rear (4.56) view (R)Vs OMEDB (.3) OMEDB (.3) OMEDB (2.83) F.G. DO2 2SCREW M3 3.5 (.55) 3.5 (.55) 3.5 (.55) F.G. F.G SCREW M DO0 (.37) DO5 (.24) (.37) Right side view 6 (4.56) 6 (4.56) 6 33 (.3) (4.56) OMEDB (2.83) OMEDB820 OMEDB (.24) (.37) 78 (3.07) (3.07) 73.3 (3.07) (2.88) (2.88) (2.88)F.G. (.37) (.37) 3.5 (.24) 2SCREW M3 The OMEDB820 daughter board 2SCREW (terminal panel) connects directly to M3 the OMEET708Z or OMEPET708Z 2SCREW 3.5 M3 2SCREW Ethernet module. (.37) (.24) 33 (.3) 72.0 (2.83) 33 (.3) 72.0 (2.83) 33 (.3) 72.0 (2.83) 2SCREW M3 2SCREW 2SCREW M3 M3 33 (.3) 72.0 (2.83) 33 (.3) 33 (.3) (2.83) (2.83) Front view (.37) (.37) (.37) DO DO4 3.5 (.24) 3.5 (.24) 3.5 (.24) DO3 Front (.37) (.24) (.24) 5

16 0Channel Thermocouple Input Modules with OMEDB820 Daughter Board OMEET70Z/OMEPET70Z U BuiltIn Web Server U Web HMI U Support for both Modbus TCP and Modbus UDP Protocols U Communication Security U Dual Watchdog U Wide Operating Temperature Range: 25 to 75 C (3 to 67 F) U I/O Pair Connection U BuiltIn I/O AI: 0 Channels with 240 Vrms Overvoltage DO: 6 Channels Applications U Building Automation U Factory Automation U Machine Automation U Remote Maintenance U Remote Diagnosis U Testing Equipment OMEET70Z shown actual size. The OMEET70Z/OMEPET70Z is a webbased Ethernet I/O module that features a builtin web server which allows remote configuration, I/O monitoring and I/O control simply by using a regular web browser. Remote control is as easy as browsing the Internet. In addition, the web HMI function means that programming or HTML skills are no longer required so creating dynamic and attractive web pages for I/O monitoring and I/O control purposes is easy. The OMEET70Z/ OMEPET70Z offers easy and safe access for users at anytime and from any location, and also supports the Modbus TCP protocol that ensures perfect integration with SCADA software. Furthermore, the OMEPET70Z features PoE, meaning that not only is data transmitted through an Ethernet cable but also power making installation of the OMEPET70Z easy. No more unnecessary wires with only an Ethernet cable being required to take care of everything in the field. The OMEET70Z/OMEPET70Z is specifically designed for extremely accurate thermocouple measurement and features automatic coldjunction compensation for each channel to ensure temperature output consistency and stable temperature output in the field. Current input and voltage input are both supported. Another feature is that the ten input can be individually be configured for different kinds of analog input. Open thermocouple detection and ESD/EFT/Surge protection mechanisms are also included. The six digital output can be set as alarm outputs with shortcircuit protection and overload protection. 6

17 System Specifications Models OMEET70Z OMEPET70Z Software Builtin Web Server Web HMI I/O Pair Connection Communication Ethernet Port 0/00 BaseTX with Auto MDI/MDIX PoE Protocol Modbus TCP, Modbus UDP Security ID, Password and IP Filter, module Dual Watchdog (0.8 seconds), communication (programmable) LED Indicators L (System Running) (Ethernet Link/Act) (Ethernet 0/00 M Speed) PoE Power 2Way Isolation Ethernet 500 Vdc I/O 2500 Vdc 2500 Vdc EMS ESD (IEC ) 4 kv contact for each terminal and 8 kv air for random point EFT (IEC ) ±4 kv for power Surge (IEC ) ±3 kv for power Power Requirements Reverse Polarity Powered from Terminal Block, 0 to 30 Vdc, 2 to 48 Vdc Powered from PoE, IEEE 802.3af, Class Consumption 2.5 W 3.5 W Mechanical Dimensions (W x L x D) 72 x 6 x mm (2.83 x 4.56 x.37") Installation DINrail or wall mounting Environment Operating Temperature 25 to 75 C (3 to 67 F) Storage Temperature 30 to 80 C ( to 76 F) Humidity 0 to 0% RH, noncondensing I/O Specifications Analog Input Channels 0 (differential) ±5 mv, ±50 mv, ±00 mv, ±50 mv, ±500 mv, ± V, ±2.5 V, ±5 V, ±0 V, Sensor Type ±20 ma, 0 to 20 ma, 4 to 20 ma (jumper selectable) Thermocouple (J, K, T, E, R, S, B, N, C, L, M, and LDIN4370) Individual Channel Configuration Resolution 6bit Sampling Rate 0 samples/second (total) Accuracy ±0.% of FSR or better Zero Drift ±0.5 μv/ C Span Drift ±25 ppm/ C Over Voltage 240 Vrms Input Impedance >300 kω Common Mode Rejection 86 db minimum Normal Mode Rejection 00 db Temperature Output Consistency Stable Temperature Output in the Field Open Wire Detection Digital Output Channels 6 Type Isolated open collector / (NPN/PNP) Maximum Load Current 700 ma/channel Load Voltage 5 to 50 Vdc Overvoltage 60 Vdc Overload.4 A ShortCircuit PowerOn Value, programmable Safe Value, programmable Front Rear The OMEDB820 daughter board (terminal panel) connects directly to the OMEET70Z or OMEPET70Z Ethernet module. SM or Shop Online at omega.com 7

18 Pin Assignments F.G. F.G OMEDB820 (.24) 3.5 (.24) 3.5 (.24) COM 2SCREW 3.5 M3 (.24) OMEET70Z 2SCREW M3 2SCREW M3 3.5 (.24) (R)Vs DO4 DO5 3.5 (.55) 3.5 (.55) 3.5 (.55) 2SCREW 33 (.3) 72.0 (2.83) 33 (.3) 72.0 (2.83) Voltage Input (Default) 3.5 OMEDB820 CH OMEDB820 V OMEDB820 OMEDB (2.28) 78 (3.07) (3.07) 78 (2.88) (3.07) 73.3 Thermocouple 73.3 (2.88) (2.88) 64 (2.52) (2.28) (3.07)V 58 (2.28) (2.52) (2.88) 64 (2.52) 78 (3.07) 73.3 (2.88) OMEDB (2.28) 5 to 50 Vdc V CH V CH0.8 CH CH 58 (2.28) (0.42) (2.52) (0.42)CH 5 (0.5) CH CH CH Digital Output Readback as 5 to 50 Vdc Open Collector () 5 to 50 Vdc Model No. OMEET70Z OMEPET70Z RAI5 idrnps000 OMESW05 OMESW05POE 5 (0.5) 0.8 (0.42) 5 (0.5) 5 to 50 Vdc CH CH CH 5 to 50 Vdc 5 to 50 Vdc 5 (0.5) 5 (0.5) 0.8 (0.42) Left side view 2.8 (0.5) CH0.8 (0.42) 2.8 (0.5) Bottom view 0.8 (0.42) 65 ( (0.5) 2.8 (0.5) 2.8 (0.5) 2.8 (0.5) 2.8 (0.5) Top view OFF State Readback as 0 5 to 50 Vdc Description 0channel thermocouple input module with OMEDB820 daughter board 0channel thermocouple input module with OMEDB820 daughter board with PoE mm (.4") DIN rail, m (3.3') length DIN rail power supply, 5 to 240 Vac input, 24 Vdc output at 850 ma 5port unmanaged ethernet switch 5port POE ethernet switch (four 0/00 base TX ports with POE and one 0/00 base TX uplink port) Comes complete with wall mount bracket, quick start guide, utility software and operator s manual on CD. Ordering Example: OMEET70Z 0channel thermocouple input module with OMEDB820 daughter board and OCW OMEGACARESM extends standard year warranty to a total of 2 years (0.42) (0.42) (0.5) 5 ( (0.42) 5 65 (0.5) (2.55) 0.8 (0.42) Rear view 0.8 (0.42) 5 (0.5) CH 5 (0.5) 0.8 (0.42) CH0.8 (0.42) 6 (4.56) 6578 (2.55) (3.07) (2.55) 65 (.37) (2.88) 3.5 (2.55) 2.8 (.55) (0.5) CH 2.8 (0.5) 2.8 CH(0.5) Vdc 5 to 50 5 to 50 Vdc Bottom view (2.52)(2.55) CH5 (0.5) 3.5 (.55) 58 (2.28) 0.8 (0.42) (0.5) (0.42) (0.42) 78 5 (0.5) (3.07) (0.5) 73.3 CH (2.88) OMEDB820 2 (0.8 (.37) (.37) (.37) (.37) Front view 64 (2.52) 64 (2.52) 64 (2.52) CH CH CHCH CHCH Input (Default) Rear view 3.5 CH(.55) Current Input 58 (2.28) 64 (2.52) 33 (.3) 72.0 (2.83) (.55) (.55) DIN rail(.55) mounting bracket (.37) 2SCREW 6 M3 (4.56) OMEDB (2.28) 58 (2.28) 64 (2.52) 58 (2.28) Wire M3Connections 3.5 (.55) Top view 78 (3.07) (3.07) (3.07) (2.88) (4.56) (2.88) (2.88) (.37) 2SCREW M3 OMEDB820 OMEDB820 (.37) (.37) (.37) 3.5 (.24) Right side view 6 (4.56) 6 33 (.3) (4.56) (2.83) (4.56) (.24) OMEDB820 DO2 DO3 DO DO0 33 (.3) 72.0 (2.83) 33 (.3) (.3) 72.0 (2.83) 33 2SCREW 72.0 (2.83) M3 (.37) (.24) (.24) 2SCREW M3 2SCREW 2SCREW M3 M3 Front view (.37) L 33 (.3) 72.0 (2.83) 33 (.3) 33 (.3) (2.83) (2.83) (.37) (.37) (.37) CON 3.5 (.24) Dimensions: mm (inch)

19 Multifunction Analog/Digital I/O Modules OMEET7026/OMEPET7026 U BuiltIn Web Server U Web HMI U Support for Both Modbus TCP and Modbus UDP Protocols U Communication Security U Dual Watchdog U Wide Operating Temperature Range: 25 to 75 C (3 to 67 F) U I/O Pair Connection U BuiltIn I/O AI: 6 Channels with 240 Vrms Overvoltage AO: 2 Channels DI/Counter: 2 Channels DO: 2 Channels Applications U Building Automation U Factory Automation Wire Connections U Machine Automation U Remote Maintenance U Remote Diagnosis mv/v V U Testing Equipment Voltage Input OMEPET7026 shown smaller than actual size. JUMPER Default The OMEET7026/OMEPET7026 is a webbased Ethernet I/O module that features a builtin web server which allows remote configuration, I/O monitoring and I/O control simply by using a regular web browser. Remote control is as easy as browsing the Internet. In addition, the web HMI function means that programming or HTML skills are no longer required so creating dynamic and attractive web pages for I/O monitoring and I/O control purposes is easy. The OMEET7026/ OMEPET7026 offers easy and safe access for users at anytime and from any location, and also supports the Modbus TCP protocol that ensures perfect integration with SCADA software. Furthermore, the OMEPET7026 features PoE, meaning that not only is data transmitted through an Ethernet cable but also power making installation of the OMEPET7026 easy. No more unnecessary wires with only an Ethernet cable being required to take care of everything in the field. The OMEET7026/OMEPET7026 is a multifunction module; there are 6channel analog inputs, 2channel analog output, 2channel digital inputs and 2channel digital outputs. It provides programmable input range on all analog inputs (±500 mv, ± V, ±5 V, ±0 V, ±20 ma, 0 to 20 ma and 4 to 20 ma), analog outputs are 2 bit with ±5 V, ±0 V, 0 to 20 ma and 4 to 20 ma and digital output can be set as alarm output. Each analog input is allowed to configure an individual range and has 240 Vrms high overvoltage protection. Modules are jumper selectable for voltage or current inputs/outputs. Digital Input/ Counter Dry Contact Digital Output Open Collector () ma Load Load Current Input Vin Vin Vin Vin Voltage Output v Vout Current Output Readback as Readback as 5 to 50 Vdc Vout DIx ISO GND JUMPER Default OFF State Readback as 0 DIx ISO GND OFF State Readback as 0 5 to 50 Vdc SM or Shop Online at omega.com

20 20 Vout0 Vin5 Vin5 Vin4 Vin4 Vin3 Vin3 Vin2 Vin2 Vin Vin Vin0 Vin0 System Specifications Models OMEET7026 L OMEPET7026 Software Builtin Web ET7026 Server Web HMI I/O Pair Connection Communication Ethernet Port 0/00 basetx with auto MDI/MDIX PoE Protocol Modbus TCP, Modbus UDP Security ID, password and IP filter Dual Watchdog, module (0.8 seconds), communication (programmable) LED Indicators L (System Running) (Ethernet Link/Act) (Ethernet 0/00 M Speed) PoE Power 2Way Isolation Ethernet 500 Vdc I/O 2500 Vdc 2500 Vdc EMS ESD 4 kv contact for each terminal and (IEC ) 8 kv air for random point EFT ±4 kv for power (IEC ) Power Requirements Reverse Polarity Powered from, 0 to 30 Vdc, 2 to 48 Vdc Terminal Block Powered from PoE Consumption 3. W 4.2 W Mechanical Dimensions (W x L x D) Installation Environment Operating Temperature Storage Temperature Humidity Vout DI0 DI DO0 DO (R)Vs Pin Assignments 0 (R)Vs, IEEE 802.3af, class 72 x x mm (2.83 x 4.84 x.37") DINrail or wall mounting 25 to 75 C (3 to 67 F) 30 to 80 C ( to 76 F) 0 to 0% RH, noncondensing Model No. Description OMEET7026 Multifunction analog/digital I/O module OMEPET7026 Multifunction analog/digital I/O PoE module RAI5 mm (.4") DIN rail, m (3.3') length idrnps000 DIN rail power supply, 5 to 240 Vac input, 24 Vdc output at 850 ma OMESW05 5port unmanaged ethernet switch 5port POE ethernet switch (four 0/00 OMESW05POE base TX ports with POE and one 0/00 base TX uplink port) Comes complete with wall mount bracket, quick start guide, utility software and operator s manual on CD. Ordering Example: OMEET7026 multifunction analog/digital I/O module and OCW OMEGACARE SM extends standard year warranty to a total of 2 years. Vout DI0 DI DO0 DO I/O Specifications Analog Input Channels 6 (differential) ±500 mv, ±V, ±5 V, ±0 V Type 0 to 20 ma, ±20 ma, 4 to 20 ma (jumper selectable) Individual Channel Configuration Resolution Normal Mode 6bit Fast Mode 2bit Sampling Normal Mode 0 samples/second (total) Rate Fast Mode 60 samples/second (total) Accuracy Normal Mode ±0.% Fast Mode ±0.5% or better Zero Drift ±20 μv/ C Span Drift ±25 ppm/ C Overvoltage 240 Vrms Input Impedance 2 MΩ Common Mode Rejection 86 db minimum Normal Mode Rejection 00 db Analog Output Channels 2 0 to 5 Vdc, ±5 Vdc, 0 Vdc to Type 0 Vdc, ±0 Vdc, 0 to 20 ma, 4 to 20 ma (jumper selectable) Individual Channel Configuration Resolution 2bit Accuracy ±0.% of FSR Voltage Output Capability 20 0 V Current Load Resistance 500 Ω Open Wire Detection, for 4 to 20 ma only Poweron Value, programmable Safe Value, programmable Digital Input/Counter Channels 2 On Voltage Level Close to GND Dry Off Voltage Level Open Contact Effective () Distance for Dry 500 M maximum Wet contact (/ ) Contact On Voltage Level Off Voltage Level Vdc maximum 3.5 to 30 Vdc Channels 2 Maximum Count 4,24,67,285 (32bit) Counters Maximum Input Frequency 00 Hz Minimum Pulse Width 5 ms Overvoltage 30 Vdc Digital Output Channels 2 Type Isolated open collector / (NPN/PNP) Maximum Load Current 700 ma/channel Load Voltage 5 to 50 Vdc Overvoltage 60 Vdc Overload.4 A ShortCircuit Poweron Value, programmable Safe Value, programmable

21 6Channel Isolated Digital Output Modules OMEET7042/OMEPET7042 U BuiltIn Web Server U Web HMI U Support for both Modbus TCP and Modbus UDP Protocols U Communication Security U Dual Watchdog U Wide Operating Temperature Range: 25 to 75 C (3 to 67 F) U I/O Pair Connection U BuiltIn I/O DO: 6 Channels Applications U Building Automation U Factory Automation U Machine Automation U Remote Maintenance U Remote Diagnosis U Testing Equipment OMEET7042 shown actual size. OMEPET7042 shown actual size. The OMEET7042/OMEPET7042 is a webbased Ethernet digital output module that features a builtin web server which allows configuration, I/O monitoring and I/O control by simply using a web browser. Using the web HMI function, no more programming or HTML skills are required. The user can create dynamic and attractive web pages easily. The module offers easy and safe access for users at anytime and from any location. It also supports Modbus TCP protocol that makes perfect integration to SCADA software. The module provides 6 sinktype digital output. It features optical isolation for 3750 Vrms of transient overvoltage protection and doesn t have channeltochannel isolation. The poweron value and safe value of digital output channel are programmable. SM or Shop Online at omega.com 2

22 I/O Specifications Models OMEET7042 OMEPET7042 System Specifications Models OMEET7042 OMEPET7042 Software Builtin Web Server Web HMI I/O Pair Connection Communication Ethernet Port 0/00 basetx with auto MDI/ MDIX PoE Protocol Modbus TCP, Modbus UDP Security ID, password and IP filter Dual Watchdog, module (0.8 seconds), communication (programmable) LED Indicators L (System Running) (Ethernet Link/Act) (Ethernet 0/00 M Speed) PoE Power 2Way Isolation Ethernet 500 Vdc I/O 3750 Vrms 3750 Vrms EMS ESD (IEC ) 4 kv contact for each Output terminal Type Output Type EFT (IEC ) ±2 kv for power Power Requirements Drive Relay Drive Relay Reverse Polarity Powered from Terminal Block, 0 to 30 Vdc, 2 to 48 Vdc Resistance Powered from PoE, Resistance IEEE Load 802.3af, Loadclass Consumption 2.7 W 3.0 W Mechanical Dimensions (W x L x D) 72 x x mm (2.83 x 4.84 x.37") Installation DINrail or wall mounting Environment Operating Temperature 25 to 75 C (3 to 67 F) Storage Temperature 30 to 80 C ( to 76 F) Humidity 0 to 0% RH, noncondensing Digital Output Channels 6 Type Isolated open collector / (NPN/PNP) Maximum Load Current Load Voltage Overvoltage Overload Shortcircuit Poweron Value Safe Value Wire Connections Output Type Output Type Drive Relay Drive Relay Output Type Readback as Readback as Readback as Readback as Readback as Drive Delay Resistance Load Resistance Resistance Load Load 00 ma/channel at 25 C direct drive power relay module 5 Vdc to 30 Vdc 60 Vdc.3 A, programmable, programmable DO DO0 DO DO8 DO7 DO6 DO5 DO4 DO3 DO2 DO DO0 ET7042 Pin Assignments OMEET DO DO0 DO DO8 DO7 DO6 DO5 DO4 DO3 DO2 DO DO0 DO DO0 DO DO8 DO7 DO6 DO5 DO4 DO3 DO2 DO DO0 0 OFF State Readback as 0 OFF State OFF State OFF State Readback as Readback as 0 Readback OFF State as 0 Readback as 0 L 0 To Order Visit omega.com/omeet7000_omepet7000 for Pricing and Details Model No. OMEET7042 OMEPET7042 RAI5 idrnps000 Description 6channel isolated digital output module 6channel isolated digital output module with PoE mm (.4") DIN rail, m (3.3') length DIN rail power supply, 5 to 240 Vac input, 24 Vdc output at 850 ma OMESW05 5port unmanaged ethernet switch 5port POE ethernet switch (four OMESW05POE 0/00 base TX ports with POE and one 0/00 base TX uplink port) Comes complete with wall mount bracket, quick start guide, utility software and operator s manual on CD. Ordering Example: OMEET7042 6channel isolated digital output module and OCW OMEGACARE SM extends standard year warranty to a total of 2 years. PET7042 DO2 DO2 DO3 DO3 DO4 DO5 ET7042 DO5 OMEPET7042 (R)Vs DO2 DO3 DO4 DO5 2 2 (R)Vs DO4 (R)Vs L L 0 DO DO0 DO DO8 DO7 DO6 DO5 DO4 DO3 DO2 DO DO0 PET7042 L

23 8Channel DI and 8Channel Isolated Digital Output Modules OMEET7044/OMEPET7044 U BuiltIn Web Server U Web HMI U Support for both Modbus TCP and Modbus UDP Protocols U Communication Security U Dual Watchdog U Wide Operating Temperature Range: 25 to 75 C (3 to 67 F) U I/O Pair Connection U BuiltIn I/O DI/Counter: 8 Channels DO: 8 Channels Applications U Building Automation U Factory Automation U Machine Automation U Remote Maintenance U Remote Diagnosis U Testing Equipment OMEET7044 shown smaller than actual size. The OMEET7044/OMEPET7044 is a webbased Ethernet digital I/O module that features a builtin web server which allows configuration, I/O monitoring and I/O control by simply using a web browser. Using the web HMI function, no more programming or HTML skills are required. The user can create dynamic and attractive web pages easily. The module offers easy and safe access for users at anytime and from any location. It also supports Modbus TCP protocol that makes perfect integration to SCADA software. Wire Connections Digital Input/Counter Readback as Readback as 0 Digital as Readback as 0 Digital Input/Counter Digital DigitalInput/Counter Digital Input/Counter Output Type Output Type Output Output Type Type Output Type Drive Relay Resistance Load Load Drive Drive Relay Relay Drive Relay Resistance Resistance Load Drive Relay Resistance Load Readback Readback as Readback as 0 as as Readback as 0 0 ~ 50 VDC Readback as OPEN or <4 VDC Readback as 0 0 ~ 50 VDC OPEN or <4 VDC 0K 0K 0K 0K 0K 0K 0K 0K 0K 0K 0 ~ 50 0 to 0 VDC OPEN or <4 VDC 0 Vdc ~ 50 VDC 50 VDC Open OPEN or or <4 VDC VDC < 4 Vdc To other To To other 0 ~ 50 VDC OPEN or <4 VDC 0 0 to ~ 50 0 VDC Vdc 0 ~ 50 VDC OPEN or Open <4 VDC ~ 50 VDC VDC OPEN OPEN or or <4 or VDC VDC < <4 4 VDCVdc 0K 0K 0K 0K To other Readback as Readback as Readback Readback as as The module provides 8 wet contact digital input and 8 sinktype digital output. It features optical isolation for 3750 Vrms of transient overvoltage protection but doesn t provide channeltochannel isolation. Each input channel can be used as a 32bit counter and each output channel can drive 300 ma load. The poweron value and safe value of digital output channel are programmable. It can safely be used in applications where hazardous voltages are present. 0K 0K 0K 0K To other OFF OFF State State OFF Readback State as as 0 0 OFF OFF State State Readback Readback as as 00 as 0 SM or Shop Online at omega.com

24 System Specifications Models OMEET7044 OMEPET7044 Software Builtin Web Server Web HMI I/O Pair Connection Communication Ethernet Port 0/00 basetx with auto MDI/ MDIX PoE Protocol Modbus TCP, Modbus UDP Security ID, password and IP filter Dual Watchdog, module (0.8 seconds), communication (programmable) LED Indicators L (System Running) (Ethernet Link/Act) (Ethernet 0/00 M Speed) PoE Power 2Way Isolation Ethernet 500 Vdc I/O 3750 Vdc 3750 Vdc EMS ESD (IEC ) 4 kv contact for each terminal EFT (IEC ) ±2 kv for power Power Requirements Reverse Polarity Powered from Terminal Block, 0 to 30 Vdc Powered from PoE, 2 to 48 Vdc, IEEE 802.3af, class Consumption 2.4 W 3.0 W Mechanical Dimensions (W x L x D) 72 x x mm (6.77 x 4.84 x.38") Installation Environment Operating Temperature Storage Temperature Humidity DINrail or wall mounting 25 to 75 C (3 to 67 F) 30 to 80 C ( to 76 F) 0 to 0% RH, noncondensing I/O Specifications Digital Input/Counter Channels 8 Contact Wet contact / (NPN/PNP) /source On Voltage Level 0 to 50 Vdc Off Voltage Level 4 Vdc maximum Input Impedance 0 kω Maximum Count 4,24,67,285 (32 bits) Counters Maximum Input Frequency 500 Hz IN2 IN IN0 DO7 DO6 DO5 DO4 DO3 DO2 DO DO0 Minimum Pulse Width ms Overvoltage 70 Vdc Digital Output Channels 8 Type Isolated open collector / (NPN/PNP) Maximum Load Current 300 ma/channel at 25 C L (77 F) direct drive power relay module Load Voltage 0 to 40 Vdc Overvoltage ET Vdc Overload. A Shortcircuit Poweron Value, programmable Safe Value, programmable Pin Assignments IN2 IN IN0 DO7 DO6 DO5 DO4 DO3 DO2 DO DO0 ET IN3 IN4 IN5 IN6 IN7 2 (R)Vs L To Order Visit omega.com/omeet7000_omepet7000 for Pricing and Details Model No. OMEET7044 OMEPET7044 RAI5 idrnps000 OMESW05 Description 8channel DI and 8channel DO module 8channel DI and 8channel DO module with PoE mm (.4") DIN rail, m (3.3') length DIN rail power supply, 5 to 240 Vac input, 24 Vdc output at 850 ma 5port unmanaged ethernet switch OMESW05POE 5port POE ethernet switch (four 0/00 base TX ports with POE and one 0/00 base TX uplink port) Comes complete with wall mount bracket, quick start guide, utility software and operator s manual on CD. Ordering Example: OMEET7044 8channel DI and 8channel DO module and OCW OMEGACARE SM extends standard year warranty to a total of 2 years. 24 IN3 IN4 IN5 IN6 IN7 2 (R)Vs

25 2Channel DI and 6Channel Isolated Digital Output Modules OMEET7050/OMEPET7050 U BuiltIn Web Server U Web HMI U Support for both Modbus TCP and Modbus UDP Protocols U Communication Security U Dual Watchdog U Wide Operating Temperature Range: 25 to 75 C (3 to 67 F) U I/O Pair Connection U BuiltIn I/O DI/Counter: 2 Channels DO: 6 Channels Applications U Building Automation U Factory Automation U Machine Automation U Remote Maintenance U Remote Diagnosis U Testing Equipment OMEET7050 shown smaller than actual size. The OMEET7050/OMEPET7050 is a webbased Ethernet digital I/O module that features a builtin web server which allows configuration, I/O monitoring and I/O control by simply using a web browser. Using the web HMI function, no more programming or HTML Wire Connections Digital Input/Counter Readback as Readback as 0 Digital Input/Counter Digital Input/Counter Output Type Output Type Output Type Drive Relay Drive Relay Readback as Readback as 0 0 Readback to 50 as as Vdc Open Readback or as as < 04 Vdc 0 ~ 50 VDC OPEN or <4 VDC 0 0K ~ 50 VDC VDC OPEN or or 0K <4 <4 VDC VDC 0K 0K 0K 0K To To other To To other 0 to 0 50 ~ 50 Vdc VDC Open OPEN or <4 < VDC 4 Vdc 0 ~ 50 VDC VDC OPEN or or <4 <4 VDC VDC 0K 0K 0K 0K 0K To other To To other ON ON Readback State as Readback as as skills are required. The user can create dynamic and attractive web pages easily. The module offers easy and safe access for users at anytime and from any location. It also supports Modbus TCP protocol that makes perfect integration to SCADA software. To To other OFF State OFF Readback State as as 0 0 Readback as as 0 Resistance Resistance Load Load SM or Shop Online at omega.com 25

26 L ET7050 The module provides 2 wet contact digital input and 6 sinktype digital output. It features optical isolation for 3750 Vrms of transient overvoltage protection but doesn t provide channeltochannel isolation. Each input channel can be used as a 32bit counter and each output channel can drive 00 ma load. The poweron value and safe value of digital output channel are programmable. System Specifications Models OMEET7050 OMEPET7050 Software Builtin Web Server Web HMI I/O Pair Connection Communication Ethernet Port 0/00 basetx with auto MDI/ MDIX PoE Protocol Modbus TCP, Modbus UDP Security ID, password and IP filter Dual Watchdog, module (0.8 seconds), communication (programmable) LED Indicators L (System Running) (Ethernet Link/Act) (Ethernet 0/00 M Speed) PoE Power 2Way Isolation Ethernet 500 Vdc I/O 3750 Vrms 3750 Vrms EMS ESD (IEC ) 4 kv contact for each terminal EFT (IEC ) ±2 kv for power Power Requirements Reverse Polarity Powered from Terminal Block, 0 to 30 Vdc, 2 to 48 Vdc Powered from PoE, IEEE 802.3af, class Consumption 2.4 W 3.0 W Mechanical Dimensions (W x L x D) 72 x x mm (2.83 x 4.84 x.37") Installation DINrail or wall mounting Environment Operating Temperature 25 to 75 C (3 to 67 F) Storage Temperature 30 to 80 C ( to 76 F) Humidity 0 to 0% RH, noncondensing Pin Assignments IN5 IN4 IN3 IN2 IN IN0 DO5 DO4 DO3 DO2 DO DO0 I/O Specifications IN6 IN7 IN8 IN IN0 IN (R)Vs Models OMEET7050 OMEPET7050 Digital Input/Counter Channels 2 Contact Wet contact / (NPN/PNP) /source On Voltage Level 0 to 50 Vdc Off Voltage Level 4 Vdc maximum Input Impedance 0 kω Maximum Count 4,24,67,285 (32 bits) Counters Maximum Input 500 Hz Frequency Minimum Pulse Width ms Overvoltage 70 Vdc Digital Output Channels 6 Type Isolated open collector / (NPN/PNP) Maximum Load Current 00 ma/channel at 25 C (77 F) Direct drive power relay module Load Voltage 5 to 30 Vdc Overvoltage 60 Vdc Overload.3 A Shortcircuit Poweron Value, programmable Safe Value, programmable ET L IN6 IN7 IN8 IN IN0 IN (R)Vs Model No. OMEET7050 Description 2channel DI and 6channel DO module OMEPET7050 2channel DI and 6channel DO module with PoE RAI5 mm (.4") DIN rail, m (3.3') length idrnps000 DIN rail power supply, 5 to 240 Vac input, 24 Vdc output at 850 ma OMESW05 5port unmanaged ethernet switch OMESW05POE 5port POE ethernet switch (four 0/00 base TX ports with POE and one 0/00 base TX uplink port) Comes complete with wall mount bracket, quick start guide, utility software and operator s manual on CD. Ordering Example: OMEET7050 2channel DI and 6channel DO module and OCW OMEGACARE SM extends standard year warranty to a total of 2 years. 26

27 6Channel Isolated Digital Input Modules OMEET705/OMEPET705 U BuiltIn Web Server U Web HMI U Support for Both Modbus TCP and Modbus UDP Protocols U Communication Security U Dual Watchdog U Wide Operating Temperature Range: 25 to 75 C (3 to 67 F) U I/O Pair Connection U BuiltIn I/O DI/Counter: 6 Channels Applications U Building Automation U Factory Automation U Machine Automation U Remote Maintenance U Remote Diagnosis U Testing Equipment The OMEET705/OMEPET705 is a webbased Ethernet digital input module that features a builtin web server which allows configuration, I/O monitoring and I/O control by simply using a web browser. Using the web HMI function, no more programming or HTML skills are required. The user can create dynamic and attractive web pages easily. The module offers easy and safe access for users at anytime and from any location. It also supports Modbus TCP protocol that makes perfect integration to SCADA software. The module provides 6 wet contact digital input. Each input channel can be used as a 32bit counter. It features optical isolation for 3750 Vrms of transient overvoltage protection but doesn t provide channeltochannel isolation. It can safely be used in applications where hazardous voltages are present. OMEET705 shown actual size. Wire Connections Digital Input/Counter Readback as Readback as 0 0 to 50 Vdc Open or < 4 Vdc 0K 0K 0 to 50 Vdc Open or < 4 Vdc 0K 0K SM or Shop Online at omega.com 27

28 System Specifications Models OMEET705 OMEPET705 Software Builtin Web Server Web HMI I/O Pair Connection Communication Ethernet Port 0/00 basetx with auto MDI/ MDIX PoE Protocol Modbus TCP, Modbus UDP Security ID, password and IP filter Dual Watchdog, module (0.8 seconds), communication (programmable) LED Indicators L (System Running) (Ethernet Link/Act) (Ethernet 0/00 M Speed) PoE Power 2Way Isolation Ethernet 500 Vdc I/O 3750 Vrms 3750 Vrms EMS ESD (IEC ) 4 kv contact for each terminal EFT (IEC ) ±2 kv for power Power Requirements Reverse Polarity Powered from Terminal Block, 0 to 30 Vdc, 2 to 48 Vdc Powered from PoE, IEEE 802.3af, class Consumption 2.4 W 3.0 W Mechanical Dimensions (W x L x D) 72 x x mm (2.83 x 4.84 x.37") Installation DINrail or wall mounting Environment Operating Temperature 25 to 75 C (3 to 67 F) Storage Temperature 30 to 80 C ( to 76 F) Humidity 0 to 0% RH, noncondensing I/O Specifications Digital Input/Counter Channels 6 Contact Wet contact / (NPN/PNP) /source On Voltage Level 0 to 50 Vdc Off Voltage Level 4 Vdc maximum Input Impedance 0 kω Maximum Count 4,24,67,285 (32 bits) Maximum Input Counters Frequency 500 Hz L Minimum Pulse ms Width Overvoltage 70 Vdc IN2 IN IN0 IN IN8 IN7 IN6 IN5 IN4 IN3 IN2 IN IN0 Pin Assignments PET705 0 IN2 IN IN0 IN IN8 IN7 IN6 IN5 IN4 IN3 IN2 IN IN0 0 IN3 IN4 IN5 2 (R)Vs PET705 L To Order Visit omega.com/omeet7000_omepet7000 for Pricing and Details Model No. Description OMEET705 6channel isolated digital input module OMEPET705 6channel isolated digital input module with PoE RAI5 mm (.4") DIN rail, m (3.3') length idrnps000 DIN rail power supply, 5 to 240 Vac input, 24 Vdc output at 850 ma OMESW05 5port unmanaged ethernet switch OMESW05POE 5port POE ethernet switch (four 0/00 base TX ports with POE and one 0/00 base TX uplink port) Comes complete with wall mount bracket, quick start guide, utility software and operator s manual on CD. Ordering Example: OMEET705 6channel isolated digital input module and OCW OMEGACARE SM extends standard year warranty to a total of 2 years. IN3 IN4 IN5 2 (R)Vs 28

29 8Channel DI and 8Channel DO Modules OMEET7052/OMEPET7052 U BuiltIn Web Server U Web HMI U Support for Both Modbus TCP and Modbus UDP Protocols U Communication Security U Dual Watchdog U Wide Operating Temperature Range: 25 to 75 C (3 to 67 F) U I/O Pair Connection U BuiltIn I/O DI/Counter: 8 Channels DO: 8 Channels Applications U Building Automation U Factory Automation U Machine Automation U Remote Maintenance U Remote Diagnosis U Testing Equipment The OMEET7052/OMEPET7052 is a webbased Ethernet digital I/O module that features a builtin web server which allows configuration, I/O monitoring and I/O control by simply using a web browser. Using the web HMI function, no more programming or HTML skills are required. The user can create dynamic and attractive web pages easily. The module offers easy and safe access for users at anytime and from any location. It also supports Modbus TCP protocol that makes perfect integration to SCADA software. Wire Connections Digital Input/Counter Readback as Readback as 0 Digital Input/Counter Digital Input/Counter 0 to 50 Vdc Readback as 0 Open or < 0 4 Vdc Digital Output Digital Output Digital Output 0 ~ 50 VDC 0 ~ 50 VDC OPEN or <4 VDC OPEN or <4 VDC 0K 0K 0K 0K 0K 0K To other To other 0 to 50 Vdc Open or < 4 Vdc 0 ~ 50 VDC 0 ~ 50 VDC OPEN or <4 VDC OPEN or <4 VDC 0K 0K 0K 0K 0K 0K To other Readback as Readback as Readback as OFF State Readback as 0 To other OFF State OFF State Readback as 0 Readback as 0 OMEET7052 shown actual size. The module provides 8 wet contact digital input and 8 sourcetype digital output. It features optical isolation for 3750 Vrms of transient overvoltage protection but doesn t provide channeltochannel isolation. Each input channel can be used as a 32bit counter and each output channel can drive 650 ma load. The poweron value and safe value of digital output channel are programmable. It can safely be used in applications where hazardous voltages are present. Inverse protection Inverse protection Inverse protection Inverse protection Load Fuse Overvoltage Load Fuse ESD Overvoltage ESD Current 0KCurrent Limit Limit Load 0K Fuse Overvoltage Load Fuse ESD Overvoltage Current Limit ESD 0KCurrent Limit 0K SM or Shop Online at omega.com 2

30 System Specifications Models OMEET7052 OMEPET7052 Software Builtin Web Server Web HMI I/O Pair Connection Communication Ethernet Port 0/00 basetx with auto MDI/MDIX PoE Protocol Modbus TCP, Modbus UDP Security ID, password and IP filter Dual Watchdog, module (0.8 seconds), communication (programmable) LED Indicators L (System Running) (Ethernet Link/Act) (Ethernet 0/00 M Speed) PoE Power 2Way Isolation Ethernet 500 Vdc I/O 3750 Vrms 3750 Vrms EMS ESD (IEC ) 4 kv contact for each terminal EFT (IEC ) ±2 kv for power Power Requirements Reverse Polarity Powered from Terminal Block, 0 to 30 Vdc, 2 to 48 Vdc Powered from PoE, IEEE 802.3af, class Consumption 2.4 W 3.0 W Mechanical Dimensions (W x L x D) 72 x x mm (2.83 x 4.84 x.37") Installation DINrail or wall mounting Environment Operating Temperature 25 to 75 C (3 to 67 F) Storage Temperature 30 to 80 C ( to 76 F) Humidity 0 to 0% RH, noncondensing I/O Specifications Digital Input/Counter Channels 8 Contact Wet contact / (NPN/PNP) /source On Voltage Level 0 to 50 Vdc Off Voltage Level 4 Vdc maxmium Input Impedance 0 kω Maximum Count 4,24,67,285 (32 bits) Counters Maximum Input 500 Hz Frequency Minimum Pulse Width ms Overvoltage 70 Vdc Digital Output Channels 8 Type Isolated open collector / (NPN/PNP) Max. Load Current 650 ma/channel at 25 C L Load Voltage 0 to 40 Vdc Overvoltage 47 Vdc Overload ET7052 Shortcircuit Poweron Value, programmable Safe Value, programmable IN2 IN IN0 DO7 DO6 DO5 DO4 DO3 DO2 DO DO0 Pin Assignments IN3 IN4 IN5 IN6 IN7 2 IN.GND (R)Vs 0 IN2 IN IN0 DO7 DO6 DO5 DO4 DO3 DO2 DO DO0 0 L ET7052 To Order Visit omega.com/omeet7000_omepet7000 for Pricing and Details Model No. Description OMEET7052 8channel DI and 8channel DO module OMEPET7052 8channel DI and 8channel DO module with PoE RAI5 mm (.4") DIN rail, m (3.3') length idrnps000 DIN rail power supply, 5 to 240 Vac input, 24 Vdc output at 850 ma OMESW05 5port unmanaged ethernet switch OMESW05POE 5port POE ethernet switch (four 0/00 base TX ports with POE and one 0/00 base TX uplink port) Comes complete with wall mount bracket, quick start guide, utility software and operator s manual on CD. Ordering Example: OMEET7052 8channel DI and 8channel DO module and OCW OMEGACARE SM extends standard year warranty to a total of 2 years. 30 IN3 IN4 IN5 IN6 IN7 2 IN.GND (R)Vs

31 6Channel Isolated Digital Input Modules OMEET7053/OMEPET7053 U BuiltIn Web Server U Web HMI U Support for Both Modbus TCP and Modbus UDP Protocols U Communication Security U Dual Watchdog U Wide Operating Temperature Range: 25 to 75 C (3 to 67 F) U I/O Pair Connection U BuiltIn I/O DI/Counter: 6 Channels Applications U Building Automation U Factory Automation U Machine Automation U Remote Maintenance U Remote Diagnosis U Testing Equipment OMEET7053 shown actual size. The OMEET7053/OMEPET7053 is a webbased Ethernet digital input module that features a builtin web server which allows configuration, I/O monitoring and I/O control by simply using a web browser. Using the web HMI function, no more programming or HTML skills are required. The user can create dynamic and attractive web pages easily. The module offers easy and safe access for users at anytime and from any location. It also supports Modbus TCP protocol that makes perfect integration to SCADA software. The module provides 6 dry contact digital input. Each input channel can be used as a 32bit counter. It features optical isolation for 3750 Vrms of transient overvoltage protection but doesn t provide channeltochannel isolation. It can safely be used in applications where hazardous voltages are present. Wire Connections Digital Input/Counter Readback as OFF State Readback as 0 Dry Contact Relay Open IN.GND Relay Close IN.GND SM or Shop Online at omega.com 3

32 System Specifications Models OMEET7053 OMEPET7053 Software Builtin Web Server Web HMI I/O Pair Connection Communication Ethernet Port 0/00 basetx with auto MDI/MDIX PoE Protocol Modbus TCP, Modbus UDP Security ID, password and IP filter, Module Dual Watchdog (0.8 seconds), communication (programmable) LED Indicators L (System Running) (Ethernet Link/Act) (Ethernet 0/00 M Speed) PoE Power 2Way Isolation Ethernet 500 Vdc I/O 3750 Vrms 3750 Vrms EMS ESD (IEC ) 4 kv contact for each terminal EFT (IEC ) ±2 kv for power Power Requirements Reverse Polarity Powered from,, Terminal Block 0 to 30 Vdc 2 to 48 Vdc Powered from PoE, IEEE 802.3af, class Consumption 2.4 W 3.0 W Mechanical Dimensions (W x L x D) Installation Environment Operating Temperature Storage Temperature Humidity 72 x x mm (2.83 x 4.84 x.37") DINrail or wall mounting 25 to 75 C (3 to 67 F) 30 to 80 C ( to 76 F) 0 to 0% RH, noncondensing I/O Specifications Digital Input/Counter Channels 6 Contact Dry contact / (NPN/PNP) On Voltage Level Open Off Voltage Level Close to GND Maximum Count 4,24,67,285 (32 bits) Counters Maximum Input Frequency 500 Hz Minimum L ms Pulse Width Overvoltage ET7053 Effective Distance Pin Assignments OMEET7053 OMEPET7053 IN2 IN IN0 IN IN8 IN7 IN6 IN5 IN4 IN3 IN2 IN IN0 IN.GND M maximum IN2 IN IN0 IN IN8 IN7 IN6 IN5 IN4 IN3 IN2 IN IN0 IN.GND IN2 IN IN0 IN IN8 IN7 IN6 IN5 IN4 IN3 IN2 IN IN0 IN.GND IN3 IN4 IN5 IN.GND (R)Vs ET L IN2 IN IN0 IN IN8 IN7 IN6 IN5 IN4 IN3 IN2 IN IN0 IN.GND PET7053 PET L 0 IN3 IN4 IN5 IN.GND2 (R)Vs L IN3 IN4 IN5 IN.GND (R)Vs To Order Visit omega.com/omeet7000_omepet7000 for Pricing and Details Model No. Description OMEET7053 6channel isolated digital input module OMEPET7053 6channel isolated digital input module with PoE RAI5 mm (.4") DIN rail, m (3.3') length idrnps000 DIN rail power supply, 5 to 240 Vac input, 24 Vdc output at 850 ma OMESW05 5port unmanaged ethernet switch OMESW05POE 5port POE ethernet switch (four 0/00 base TX ports with POE and one 0/00 base TX uplink port) Comes complete with wall mount bracket, quick start guide, utility software and operator s manual on CD. Ordering Example: OMEET7053 6channel isolated digital input module and OCW OMEGACARE SM extends standard year warranty to a total of 2 years. IN3 IN4 IN5 IN.GND2 (R)Vs 32

33 6Channel Power Relay Output and DI Modules OMEET7060/OMEPET7060 U BuiltIn Web Server U Web HMI U Support for Both Modbus TCP and Modbus UDP Protocols U Communication Security U Dual Watchdog U Wide Operating Temperature Range: 25 to 75 C (3 to 67 F) U I/O Pair Connection U BuiltIn I/O DI/Counter: 6 Channels Power Relay: 6 Channels Applications U Building Automation U Factory Automation U Machine Automation U Remote Maintenance U Remote Diagnosis U Testing Equipment OMEPET7060 shown actual size. Wire Connections Digital Input/ Counter Readback as Readback as 0 0 to 50 Vdc OPEN or <4 Vdc 0K 0K OMEET7060/OMEPET7060 is a webbased ethernet digital I/O module that features a builtin web server which allows configuration, I/O monitoring and I/O control by simply using a web browser. Using the web HMI function, no more programming or HTML skills are required. The user can create dynamic and attractive web pages easily. The module offers easy and safe access for users at anytime and from any location. It also supports Modbus TCP protocol that makes perfect integration to SCADA software. The module provides 6 wet contact digital input and 6 form A electromechanical relays. It features optical isolation for 3000 Vrms of transient overvoltage protection and doesn t have channeltochannel isolation. Each input channel can be used as a 32bit counter. The poweron value and safe value of relay are programmable. Power Relay Relay Output 0 to 50 Vdc OPEN or <4 Vdc Readback as or Shop Online at omega.com RLx.COM AC/DC RLx.NO 0K Relay Close To OFF State Readback as 0 Note: When inductive loads are connected to the relays, a large counter electromotive force may occur when the relay actuates because of the energy stored in the load. These flyback voltages can severely damage the relay contacts and greatly shorten the relay life. Limit these flyback voltages at your inductive load by installing a flyback diode for DC loads or a metal IN.GNDoxide varistor for AC loads. IN.GND Relay Open Relay Close SM 33 RLx.COM 0K AC/DC RLx.NO Relay Open

Ethernet I/O Products

Ethernet I/O Products .. Overview P--.2. Modbus TCP I/O Expansion Unit P-2-.. ET-7000/PET-7000/PET-7000-48V Series (Web based) P--.4. PEE-7000/PEE-7000-48V Series (Web based) P-4-.5. tet/tpet Series Modules (IP based) P-5-.6.

More information

Ethernet I/O Module by ICP DAS Co., Ltd. All Rights Reserved. Comparison Item tpet PETL-7000 PET-7000 CPU 32-bit ARM Ethernet

Ethernet I/O Module by ICP DAS Co., Ltd. All Rights Reserved. Comparison Item tpet PETL-7000 PET-7000 CPU 32-bit ARM Ethernet Providing networking ability and various digital I/O functions, the PETL-7000 and tet/tpet series are IP-based Ethernet I/O monitoring and control modules. The module can be remotely controlled through

More information

ZigBee Products. ICP Electronics Australia Pty Ltd Overview P ZigBee Converters P5-2-1

ZigBee Products. ICP Electronics Australia Pty Ltd Overview P ZigBee Converters P5-2-1 ZigBee Products.1 Overview P11.2 ZigBee Converters P21.3 ZigBee I/O Modules P31 Overview.1. Overview ZigBee Products ZigBee Host ZB270T(PA)/20T(PA) ZigBee DIO 1 Overview ZigBee Repeater ZB210T Based on

More information

ZigBee Products 5.1 Overview P ZigBee Converters P ZigBee I/O Modules P5-3-1

ZigBee Products 5.1 Overview P ZigBee Converters P ZigBee I/O Modules P5-3-1 ZigBee Products.1 Overview P11.2 ZigBee Converters P21.3 ZigBee I/O Modules P31 Overview.1. Overview ZigBee Products ZigBee Host ZB270T(PA)/20T(PA) ZigBee DIO 1 Overview ZigBee Repeater ZB210T Based on

More information

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS I-7520 RS-232 to RS-485 Converter I-7510 RS-485 Repeater RS-232 RS-485 I-7000 SERIES Common Specifications Isolation voltage: 3000VDC Speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115000 Dual watchdog

More information

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions ICP DAS 2015 M2M WLAN Wireless Solutions Industrial Computer Industrial Product Data Computer Acquisition Product System Data Acquisition System PAC WLAN Wireless Solutions Wi-Fi Products WLAN Converter

More information

Redundant System Redundant System P9-1-1

Redundant System Redundant System P9-1-1 .. P-- Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P-- idcs-8830/idcs-8830r - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

More information

ET-7000/PET-7000 AIO series User Manual

ET-7000/PET-7000 AIO series User Manual ET-7000/PET-7000 AIO series User Manual Service and usage information for ET-7005/PET-7005 ET-7015/PET-7015 ET-7017/PET-7017 ET-7017-10/PET-7017-10 ET-7018Z/PET-7018Z ET-7019/PET-7019 Version 1.0.1 beta3,

More information

User s Guide OME-ET-7000 AND OME-PET-7000 SERIES. Ethernet I/O Modules

User s Guide OME-ET-7000 AND OME-PET-7000 SERIES. Ethernet I/O Modules egister Table User s Guide Shop online at omega.com e-mail info@omega.com For latest product manuals omegamanual.info OME-ET-7000 AND OME-PET-7000 SEIES Ethernet I/O Modules OMEGAnet On-Line Service omega.com

More information

RS-485 I/O Modules: ADAM-4000

RS-485 I/O Modules: ADAM-4000 RS-485 I/O Modules: ADAM-4000 23 ADAM-4000 Series Overview ADAM-4000 Series Remote Data Acquisition and Control Modules Overview 23-2 and Controller Module Selection Guide 23-4 I/O Module Selection Guide

More information

ET-7000 series Ethernet Remote I/O Module

ET-7000 series Ethernet Remote I/O Module ET-7000 series Ethernet Remote I/O Module User Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year, starting from the date of

More information

iologik E1200H Series

iologik E1200H Series iologik E1200H Series Ethernet remote I/O for offshore wind power applications Features and Benefits User-definable Modbus TCP Slave addressing 2-port Ethernet switch for daisy-chain topologies Active

More information

ET-7000/PET-7000 DIO Series User Manual

ET-7000/PET-7000 DIO Series User Manual ET-7000/PET-7000 DIO Series User Manual Version 1.0.1 beta2, April 2010 Service and usage information for ET-7042 ET-7044 ET-7050 ET-7051 ET-7052 ET-7053 ET-7060 ET-7065 ET-7066 ET-7067 PET-7044 PET-7051

More information

Features and Benefits. Certifications

Features and Benefits. Certifications iologik E2200 Series Smart Ethernet remote I/O with Click&Go Logic Features and Benefits Front-end intelligence with patented Click&Go control logic, up to 24 rules Active communication with MX-AOPC UA

More information

iothinx 4500 Series (45MR) Modules

iothinx 4500 Series (45MR) Modules iothinx 4500 Series (45MR) Modules Modules for iothinx 4500 Series Feature and Benefits Easy tool-free installation and removal Built-in LED indicators for IO channels Wide operating temperature range:

More information

ADAM-6200 Series. Feature. Transition and Vision on Remote DAQ Device 19-13

ADAM-6200 Series. Feature. Transition and Vision on Remote DAQ Device 19-13 ADAM-6200 Series Feature DI/O LED Indication Flexible user-defined Modbus address 19 20 21 DAQ Boards Signal Conditioning Industrial USB I/O Modules22 Transition and Vision on Remote DAQ Device In 2002,

More information

User Manual SUPPORT. Ethernet I/O Modules Ver. 1.8, Jan. 2014

User Manual SUPPORT. Ethernet I/O Modules Ver. 1.8, Jan. 2014 PETL/tET/tPET DIO Series User Manual Ethernet I/O Modules Ver. 1.8, Jan. 2014 WARRANTY All products manufactured by ICP DAS are warranted against defective materials for a period of one year from the date

More information

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch User-definable Modbus/TCP Slave addressing Supports EtherNet/IP* adapter mode Supports RESTful API for IIoT applications 2-port Ethernet

More information

PROFIBUS Products. ICP Electronics Australia Pty Ltd Overview P 5-1

PROFIBUS Products. ICP Electronics Australia Pty Ltd Overview P 5-1 5.1 Overview P 5-1 Selection Guide - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P 5-2 5.2 Converters & Repeaters P 5-3 5.3 Gateways P 5-5 5.4

More information

ICP DAS. ICP DAS 2013 M2M ZigBee Wireless Solutions

ICP DAS. ICP DAS 2013 M2M ZigBee Wireless Solutions 2013 M2M ZigBee Wireless Solutions Industrial Computer Industrial Product Data Computer Acquisition Product System Data Acquisition System PAC New ZigBee Solutions: ZT-2000 Series Products ZigBee Wireless

More information

Features and Benefits. Certifications

Features and Benefits. Certifications iologik R1200 Series RS-485 remote I/O Features and Benefits Dual RS-485 remote I/O with built-in repeater Supports the installation of multidrop communications parameters Install communications parameters

More information

ET-2200 Series Ethernet I/O Modules User Manual

ET-2200 Series Ethernet I/O Modules User Manual ET-2200 Series Ethernet I/O Modules User Manual Ethernet I/O Module Ver. 1.3.0, Jun. 2018 WARRANTY All products manufactured by ICP DAS are warranted against defective materials for a period of one year

More information

iologik 4000 Series (M) Modules

iologik 4000 Series (M) Modules iologik 4000 Series (M) s Remote I/O modules Features and Benefits I/O expansion without a backplane Active communication with MX-AOPC UA Server Supports SNMP v1/v2c Easy configuration with Modular ioadmin

More information

Related Products. 1. CAN Bus to Ethernet Gateway 2. Serial Device to Ethernet Gateway. Wireless ZigBee Series. Ethernet Layer.

Related Products. 1. CAN Bus to Ethernet Gateway 2. Serial Device to Ethernet Gateway. Wireless ZigBee Series. Ethernet Layer. Related Products 1. CAN Bus to Ethernet Gateway 2. Serial Device to Ethernet Gateway 3. Wireless ZigBee Series SCADA Data Server RS405 RS405 Ring RS405 RS405 Ethernet Layer RS405 Fieldbus Layer CAN Bus

More information

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Active communication with patented MX-AOPC UA Server and Active OPC Server 2 switched Ethernet ports for daisy-chain topologies Easy

More information

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System Features 10/100Mbps Ethernet full duplex Auto Negotiation Support C++/C Modbus/TCP drivers and OPC server Support configuration via built-in Web browsing, (HTML), Device Finder and I/O configuration utilities

More information

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Active communication with patented MX-AOPC UA Server and Active OPC server Smart alarm management with email, SNMP traps, TCP, UDP Save

More information

WISE I/O Modules Overview P10-1-1

WISE I/O Modules Overview P10-1-1 .1. Overview P-1-1 Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Application Stories - - - - - - - - - - - - - - - - - - - - - -

More information

Ethernet I/O Modules: ADAM-6000

Ethernet I/O Modules: ADAM-6000 Ethernet I/O Modules: ADAM-6000 16 ADAM-6000 Series Overview ADAM-6000 Series 16-2 Peer-to-Peer Technology 16-4 Graphic Condition Logic (GCL) Technology 16-6 ADAM-6000 Selection Guide 16-8 I/O Modules

More information

iologik E4200 Modular Active Ethernet I/O adaptor IT and Instrumentation for industry Introduction Specifications LAN Regulatory Approvals Warranty

iologik E4200 Modular Active Ethernet I/O adaptor IT and Instrumentation for industry Introduction Specifications LAN Regulatory Approvals Warranty ioogik E4200 Modular Active Ethernet I/O adaptor Supports up to 16 I/O modules Dual Ethernet ANs and one RS-232 port Front-end intelligence that supports 80 Click&Go rules Unicode Active Messaging with

More information

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety iologik 4000 Series Modular remote I/O I/O expansion without a backplane Supports SNMPv1/v2c Active communications with MX-AOPC UA Server Easy configuration with Modular ioadmin utility Friendly configuration

More information

ET-7X00/PET-7X00 Series User Manual

ET-7X00/PET-7X00 Series User Manual Version 1.1.2, February 2014 Industrial Computer Products Data Acquisition Systems ET-7X00/PET-7X00 Series User Manual ET-7000/ET-7200 Series (Ethernet I/O) PET-7000/PET-7200 Series (PoE I/O) Warranty

More information

iologic E1200 Series Remote Ethernet I/O with 2-port Ethernet Switch Introduction Industrial I/O

iologic E1200 Series Remote Ethernet I/O with 2-port Ethernet Switch Introduction Industrial I/O iologic E1200 Series Remote Ethernet I/O with 2-port Ethernet Switch Build-in 2-port Ethernet switch for daisy-chained topology Free push-based Moxa Active OPC Server Lite support Seamlessly connect to

More information

Ethernet I/O Modules: ADAM-6000

Ethernet I/O Modules: ADAM-6000 Ethernet I/O Modules: ADAM-6000 24 EtherNet/IP I/O Modules EtherNet/IP I/O Module Introduction 24-2 ADAM-6100 Series Selection Guide 24-3 ADAM-6117EI (New) ADAM-6118EI (New) ADAM-6150EI (New) ADAM-6160EI

More information

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type

More information

8 Channel Analog Input Module Datasheet. Address / Baud rate / range configurable by the user

8 Channel Analog Input Module Datasheet. Address / Baud rate / range configurable by the user 8 Channel Analog Input Module Datasheet User s Manual Overview: DAM module is a new generation data acquisition and control system based on modular embedded systems. Adopting standard DIN35 rail mounting

More information

E2000 Series Active Remote I/O

E2000 Series Active Remote I/O E2000 Series Realtime-ize Your Data Acquisition and Control System a new breed of I/O server for intelligent, PC-based automation over Ethernet Traditional Ethernet remote I/O solutions have been on the

More information

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications IA260 Series Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA Features and Benefits Cirrus Logic EP9315 Arm9 CPU, 200 MHz 128 MB RAM onboard, 32 MB flash disk

More information

iologik R1200 Series User s Manual

iologik R1200 Series User s Manual User s Manual First Edition, April 2013 www.moxa.com/product 2013 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used

More information

ET-7000/PET-7000 Series User Manual

ET-7000/PET-7000 Series User Manual Version 1.1.1, Apri l 2013 Industrial Computer Products Data Acquisition Systems ET-7000/PET-7000 Series User Manual ET-7000 Series (Ethernet I/O) PET-7000 Series (PoE I/O) Warranty All products manufactured

More information

Warranty. Warning. Copyright. Contact Us

Warranty. Warning. Copyright. Contact Us M-6026U-32 16-channel Universal Input and 16-channel Universal Output Version: 1.0.0 Date: Dec. 2017 Edited by Horse Chien M-6026U-32 User Manual Version 1.0.0 Dec. 2017-1 - Warranty All products manufactured

More information

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE ids6p www.is5com.com Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE Features Redundant Dual Ethernet Ports: Recovery time < 10ms Ethernet Switch Mode: Allows daisy chaining

More information

Features and Benefits. Certifications

Features and Benefits. Certifications EDS-P308 Series 8-port unmanaged Ethernet switches with 4 IEEE 802.3af PoE ports Features and Benefits 4 IEEE 802.3af-compliant PoE and Ethernet combo ports Up to 15.4 W output at 48 VDC per PoE port Intelligent

More information

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature Programmable Controllers iopac 8500 Series Award-winning Product Rugged modular RTU controllers Dedicated ARM (RISC) CPUs for the main system and each I/O module Millisecond timestamp granularity for digital

More information

iologik 2500 HSPA/GPRS/WLAN Series

iologik 2500 HSPA/GPRS/WLAN Series iologik 2500 HSPA/GPRS/WLAN Series Smart wireless remote I/O with Click&Go Plus Logic Introduction The iologik 2500 is a smart remote I/O product with unique hardware and software designs, making it an

More information

Features. RoHS COMPLIANT 2002/95/EC

Features. RoHS COMPLIANT 2002/95/EC PCIE-1730 32-ch TTL and 32-ch Isolated Digital I/O PCI Express Card 32-ch isolated DI/O (16-ch digital input, 16-ch digital output) 32-ch TTL DI/O (16-ch digital input,16-ch digital output) High output

More information

Ethernet I/O Modules: ADAM-6000

Ethernet I/O Modules: ADAM-6000 Ethernet I/O Modules: ADAM-6000 5 ADAM-6000 Series Smart Web Ethernet I/O Modules 5-2 ADAM-6000 Series I/O System Architecture & Product Category 5-4 ADAM-6000 Series System Configuration & Application

More information

RS-485 Products. ICP Electronics Australia Pty Ltd Communication Cards for PC/IPC P 2-1

RS-485 Products. ICP Electronics Australia Pty Ltd Communication Cards for PC/IPC P 2-1 2.1 Communication Cards for PC/IPC P 2-1 2.2 Communication Modules for PAC P 2-2 2.3 Converter/Repeater/Hub/Splitter P 2-3 2.4 Termination Resistor/DC Bias Voltage P 2-5 2.5 I/O Modules P 2-6 2.6 I/O Units

More information

Trident and Trident X2 Digital Process and Temperature Panel Meter

Trident and Trident X2 Digital Process and Temperature Panel Meter Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products

More information

ADAM-6000 Series. Ethernet-based Data Acquisition and Control Modules. User Manual

ADAM-6000 Series. Ethernet-based Data Acquisition and Control Modules. User Manual ADAM-6000 Series Ethernet-based Data Acquisition and Control Modules User Manual Copyright The documentation and the software included with this product are copyrighted 2012 by Advantech Co., Ltd. All

More information

Features and Benefits. Certifications

Features and Benefits. Certifications EDS-P206A Series 6-port unmanaged Ethernet switches with 4 IEEE 802.3af/at PoE+ ports Features and Benefits IEEE 802.3af/at compliant PoE and Ethernet combo ports Up to 30 W output per PoE port 12/24/48

More information

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1 Manual PCD3.C90 Revision History Date Modification Asked by: Version 14.09.09 E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1 22.09.09 Added E/A Bus Connector PCD3.K116 Müller.R 1.2 06.01.10

More information

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES D1000 FEATURES Complete sensor to RS-232/RS-485 interface. 500V rms analog input isolation. 15 bit measurement resolution. Continuous self-calibration;

More information

Technical specification

Technical specification Technical specification EXPERT i/o extension modules Version 01.00.00 23-02-2017 This manual contains technical documentation which allows for easy installation and use of the i/o extension module product

More information

S800 I/O ABB Automation

S800 I/O ABB Automation S800 I/O 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 1 S800 I/O S800 I/O 3 : Fieldbus Communication Interface (FCI) I/O Module Module Termination Unit (MTU), Compact or Extended version 3BCNIIT F HW02-S800-V0102

More information

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017 November 2017 Module Status LED Channel Status LEDs Digital Input Connector Ground 24 V DC FE Analog Input Module RSTI-EP Slice I/O Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704,

More information

8B SLX300 Data Acquisition System

8B SLX300 Data Acquisition System 8B SLX300 Data Acquisition System Description Dataforth s newest data acquisition system builds on the proven reliability of the SLX200 SCM5B-based system and also takes advantage of the miniature size

More information

Ethernet I/O Modules: ADAM-6000

Ethernet I/O Modules: ADAM-6000 Ethernet I/O Modules: ADAM-6000 5 ADAM-6000 Series Smart Web Ethernet I/O Modules 5-2 ADAM-6000 Series I/O System Architecture & Product Category 5-4 ADAM-6000 Series System Configuration & Application

More information

3-7 Tiny Serial-to-Ethernet Device Server & Modbus Gateway

3-7 Tiny Serial-to-Ethernet Device Server & Modbus Gateway Tiny Serial-to- Device Server & Modbus Gateway - Tiny Serial-to- Device Server & Modbus Gateway tds-00 Series NEW tds-12 tds-00 series Tiny Serial-to- Device Server Features Incorporates any /422/485 serial

More information

UK +44 (0) // USA // JAPAN //

UK +44 (0) // USA // JAPAN // 4 Analogue Outputs Ethernet to Analogue I/O 4 Analogue Outputs - Selectable as either current or Voltage Supports simple ASCII or industry standard Modbus TCP 1 Ethernet Port -30 C to +80 C/-22ºF to +176ºF

More information

iologik E1200 Series User s Manual

iologik E1200 Series User s Manual User s Manual Edition 14.3, June 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used

More information

BUENO ELECTRIC. Https://www.bueno-electric.com. BE-6000 Series. Remote I/O Modules. Contact: Fax:

BUENO ELECTRIC. Https://www.bueno-electric.com. BE-6000 Series. Remote I/O Modules. Contact: Fax: Https://www.bueno-electric.com BUENO ELECTRIC BE-6000 s Contact: sales@bueno-electric.com Fax: +86-25-51816989 Chapter 1 Product Overview 1.1 Product Introduction (RS-6000M) RS-6000M RS485-based data acquisition

More information

Safety: UL508 EMC: CE IEC , IEC Vibration: IEC (2 g s during operation) Warranty

Safety: UL508 EMC: CE IEC , IEC Vibration: IEC (2 g s during operation) Warranty NA-4020/4021 RS-485 or RS-232 network adaptors ioogik 4000 Modbus RS-485 NA-4020 SYS TxD RxD I/O Field Power CH0 24V 0V SG SG System Power (0 VDC) System Power (24 VDC) Shielding Ground Non-isolation Switching

More information

RD2000, 5.6" display. All models shown smaller than actual size.

RD2000, 5.6 display. All models shown smaller than actual size. Paperless Recorders RD1000/RD2000/RD3000 Series RD1000, 4.3" display RD2000, 5.6" display RD3000, 12.1" display All models shown smaller than actual size. Color TFT Touch Screen Display: 4.3", 5.6" and

More information

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES 11/17 D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES D7000 FEATURES Complete data acquisition systems. Analog and Digital I/O models available. RJ-45 Ethernet 10/100MB interface. Modbus TCP/IP Ethernet

More information

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018 September 2018 Module Status LED Channel Status LEDs Digital Input Connector Ground 24 V DC FE Analog Input Module RSTI-EP Slice I/O Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664,

More information

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere!   Toll Free Digital Indicating Controllers JC Series High performance controllers...at the lowest prices anywhere! www.mod-tronic.com Toll Free 1-800 794-5883 Standard Features Structure Units available in standard

More information

BE-6000Series Remote I/O Module

BE-6000Series Remote I/O Module www.buenoptic.net BE-6000Series Chapter 1 Product Overview 1.1 Product Introduction(RS-6000M) RS-6000M RS485-based data acquisition and control modules provide I/O, data acquisitions, and networking in

More information

RS-485 I/O Products I-7000 and M-7000 Modules P tm Series Modules P RS-485 I/O Expansion Unit P2-4-1

RS-485 I/O Products I-7000 and M-7000 Modules P tm Series Modules P RS-485 I/O Expansion Unit P2-4-1 .1. Overview P-1-1.. I-7000 and M-7000 Modules P--1.3. tm Series Modules P-3-1.4. RS-485 I/O Expansion Unit P-4-1.5. Termination Resistor/DC Bias Voltage P-5-1.6. RS-485 Converter/Repeater/Hub/Splitter

More information

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual. Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-RTD6 Installation Guide. The 2300 series stations are designed to

More information

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS ELK. ETK COMPACT BASIC CONTROL - SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS TIMER - SOFT START OUTPUT

More information

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET & DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-A8VI Installation Guide. The 2300 series stations are designed to

More information

iologik E1200 Series User s Manual

iologik E1200 Series User s Manual User s Manual Tenth Edition, April 2013 www.moxa.com/product 2013 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. User s Manual The software described in this manual is furnished

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

WHERE THE FUTURE MEETS THE PRESENT. Datascan. solo Network Based Data Acquisition System

WHERE THE FUTURE MEETS THE PRESENT. Datascan. solo Network Based Data Acquisition System WHERE THE FUTURE MEETS THE PRESENT Datascan solo Network Based Data Acquisition System CONTENTS INTRODUCTION 1 ANALOG INPUT/OUTPUT MODULES &3 DIGITAL INPUT/OUTPUT MODULES PRODUCT FEATURES &5 NETWORK CONTROLLERS,

More information

Outline. EtherNet/IP Introduction EtherNet/IP products EtherNet/IP Ring Topology Implicit and Explicit Message Applications

Outline. EtherNet/IP Introduction EtherNet/IP products EtherNet/IP Ring Topology Implicit and Explicit Message Applications EtherNet/IP Outline EtherNet/IP Introduction EtherNet/IP products EtherNet/IP Ring Topology Implicit and Explicit Message Applications Outline EtherNet/IP Introduction EtherNet/IP products EtherNet/IP

More information

ADAM-5000 Series. I/O Module User's Manual

ADAM-5000 Series. I/O Module User's Manual ADAM-5000 Series I/O Module User's Manual 2.4 rd Edition May 2008 Introduction This manual introduces the detail specifications functions and application wiring of each ADAM-5000 I/O modules. To organize

More information

iologik R1200 Series User s Manual

iologik R1200 Series User s Manual User s Manual Edition 3.2, November 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used

More information

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3 INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page

More information

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATALOGGER NI2400/NI816/NI4866 8/16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATASHEET Rev. 08 del 08/10/2018 Redatto da R&D Approvato da MKT GENERAL 1SPECIFICATIONS NI4866 NI816 NI2400

More information

Ethernet to Digital I/O +RS232 +Switch

Ethernet to Digital I/O +RS232 +Switch 4 Digital I/O Lines with RS232 Serial Port 4 Digital Ports independently can be In or Out 1 RS232 Serial Port 2 Ethernet Port User friendly software interface Simple web based configuration, monitoring

More information

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS... 2 content DISPLAYS... 4 smart meters... 6 panel meters... 7 field displays... 8 display types... 10 loop powered displays... 12 TRANSMITTERS & CONVERTERS... transmitters... 15 converters... 18 serial data

More information

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual. Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-RO4 Installation Guide. The 2300 series stations are designed to

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

NetBiter I/O Extender User Manual

NetBiter I/O Extender User Manual User Manual Part no. 0920-9999-009 IntelliCom Innovation AB Pilefeltsgatan 73 SE-302 50 Halmstad SWEDEN Phone +46 35 17 29 90 Fax +46 35 17 29 09 email info@intellicom.se www www.intellicom.se Revision

More information

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 05/2009 MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES.

More information

UK +44 (0) // USA // JAPAN //

UK +44 (0) // USA // JAPAN // 8 Analogue Inputs Ethernet to Analogue I/O 8 Analogue Inputs - Selectable as either current or Voltage Supports simple ASCII or industry standard Modbus TCP 1 Ethernet Port -30 C to +80 C/-22ºF to +176ºF

More information

PD765 TRIDENT. Trident Series Process & Temperature Meters.

PD765 TRIDENT. Trident Series Process & Temperature Meters. PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) Type 4X, NEMA 4X, IP65 Front 1/8 DIN Shallow

More information

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission iopac 8020 Series Rugged modular RTU controllers Compliant with EN 50121-3-2, EN 50121-4, and a portion of EN 50155 specifications Supports C/C++ programming languages 2-port Ethernet switch for daisy-chain

More information

5.3. Ethernet I/O Expansion Unit

5.3. Ethernet I/O Expansion Unit .. Introduction The ET-87Pn series remote I/O expansion unit is designed to acquire and control remote I/O through connections. It comprises A CPU module with none-volatile memory to backup/restore I/O

More information

Industrial IEEE a/b/g/n wireless access point with 2x10/100/1000Base-T(X) Features

Industrial IEEE a/b/g/n wireless access point with 2x10/100/1000Base-T(X) Features IGAP-620 / IGAP-620+ Industrial IEEE 802.11 a/b/g/n wireless access point with 2x10/100/1000Base-T(X) Features High Speed Air Connectivity: WLAN interface support up to 300Mbps link speed Highly Security

More information

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points) Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE

More information

Active Ethernet Micro Controller User s Manual

Active Ethernet Micro Controller User s Manual iologik E2210, E2212, E2214, E2240, E2242, E2260, E2262, iologik E2210-T, E2212-T, E2214-T, E2240-T, E2242-T, E2260-T, E2262-T Second Edition, December 2010 www.moxa.com/product 2010 Moxa Inc. All rights

More information

ADAM-6000 Series. Ethernet-based Data Acquisition and Control Modules. User Manual

ADAM-6000 Series. Ethernet-based Data Acquisition and Control Modules. User Manual ADAM-6000 Series Ethernet-based Data Acquisition and Control Modules User Manual Copyright The documentation and the software included with this product are copyrighted 2014 by Advantech Co., Ltd. All

More information

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

HIGH-VOLTAGE DC METER

HIGH-VOLTAGE DC METER HIGH-VOLTAGE DC METER Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

These modules also provide advanced features like data sharing and UDP ß ood attack protection as follows: Client C. Single-Board Computer (SBC)

These modules also provide advanced features like data sharing and UDP ß ood attack protection as follows: Client C. Single-Board Computer (SBC) Palmsize Programmable Serialto Server Palmsize Programmable Serialto Server PDS70(D) PPDS70(D)MTCP Programmable Server with 1 port and 1 port PPDS70DMTCP PDS70 PDS785/D6 PDS78D5/D6 Programmable Server

More information

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450 Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450 o Measuring of resistance of RTD sensors (Pt100, Pt1000, Ni100, Cu10,...) o Accuracy class up to: 0.5 o Programmable input

More information

MIC-2 Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules

More information