Leak Test Machines ICT Requirements
|
|
- Sherman Willis
- 6 years ago
- Views:
Transcription
1 Manufacturing Engineering General Assembly (MEGA.ICT _A.01) ICT Requirements
2 1) OVERVIEW This document summarizes the current ICT requirements for new to be purchased and installed in Fiat Chrysler Automobiles (FCA) US LLC Assembly Plants. This document is managed by the ICT Assembly System Launch Management Group (ASLM) of FCA US LLC. For the latest version of this document, please contact a member of this group. Please refer to the latest Corporate Controls Standards (previously known as the BOIG; Book of Implementation Guidelines) for specific controls information. Deviations to equipment from this document must be approved through the launch deviation process. 2) SCOPE This document applies to new equipment built from 12/1/2003 forward. It does not imply that any existing equipment shall be modified to meet these requirements. It can be used as a reference for existing equipment that is being refurbished. 3) OPERATION OF EQUIPMENT QAS operation guideline (Refer to ICT documentation for additional requirements) 1) A standard Fill machine is CLx based 2) A single Ethernet connection is required, 2 communications ports will be utilized, and one for solicited PFS data, the second for unsolicited QAS downloads. 3) QAS will be utilized to deliver style information to the processor. 4) Limit switches will be used by the OEM to track the position of their fill heads 5) The operation shall not be performed without a known valid VIN number 6) Pass/Fail fields should default to a Z (bypass) at the start of a cycle. As each test or function is executed, the appropriate Pass or Fail should be entered in the correct field. 7) A Handheld scanner is required for backup; Hand scanned data will override all VIN's currently in the machine. 8) Utilize a Panel view to allow the operator to correct failed read conditions; this Panel view will allow the operator to enter the correct VIN number, hand scanning should be performed prior to going to Panel-view and inputting manually the VIN Owner: ICT Launch Management Page 2 of 14 Revision: 2.2
3 4) GENERAL PROCESS FLOW This is a general process flow from the ICT perspective: 1) Vehicle enters station 2) QAS downloads unsolicited style information to processor 3) Processor acknowledges on same port that it has received the information 4) If no information received: a) Hand Scan VIN b) ALS (See ICT integrator for more information) c) Manual VIN entry 5) Operator performs fill operation 6) Machine send data to PFS 5) AVI (AUTOMATIC VEHICLE IDENTIFICATION) If a scanner is used in the system, then AVI standards apply, specifically to hardware model numbers and the requirement for items such as beam control and stack lights. Refer to BOIG documents , (PLC-5 implementations) or (CLx implementations), and (PLC-5 implementations) or (CLx implementations), for detailed AVI Reader Implementation information. If the system is CLx based: 1) A Barcode reader requires an ICT Clx processor in slot 9. AVI and PFCS drivers will be installed in this processor. 2) A QAS download with no barcode reader will require that PFCS drivers are installed in the OEM processor and no ICT CLX is required. 3) A QAS Download will require a handheld scanner as a backup. 6) FIS (FACTORY INFORMATION SYSTEM) This equipment is required to connect to FIS for diagnostic and production information reporting. Use the following bitmap to configure the equipment for FIS reporting. Owner: ICT Launch Management Page 3 of 14 Revision: 2.2
4 LEAK TEST BITMAP Word[Bit Number] DINT state_code TEXT 0[02-15] FAULTED GLx WRONGPROGRAM DOWNLOADED 0[16-31] FAULTED GLx MODULE FAULT 1[00-09] FAULTED Ipxx POWER CB NOT ON 1[10-12] POWER OFF DIAGNOSTIC POWER OFF 1[13-15] POWER OFF CONTROL POWER OFF 1[16-31] POWER OFF E-STOP PUSHED/SAFETY PINS PULLED 2[00-15] FAULTED E-STOP /C-STOP /SAFETY PINS FAULT 2[16-19] PROD STOP CYCLE STOP 2[20-31] SPARES SPARES 3[00-10] FAULTED I/O RACK FAULT 3[11-31] FAULTED MRS SAFETY FAULT 4[00-09] POWER OFF MASTERRESET REQUIRED 4[10-13] OUT OF AUTO CYCLE ENABLERESET REQUIRED 4[14-18] OUT OF AUTO FAULT RESET REQUIRED 4[19-25] OUT OF AUTO NOT READYFOR AUTO 4[26-31] OUT OF AUTO WAITING FORSTARTUP 5[00-01] OUT OF AUTO NO MODE SELECTED 5[02-12] OUT OF AUTO MACHINE MODES "MANUAL/ CALIBRATEMODE/ MAINTENANCE MODE/ NO MODE.etc" 5[13-14] BYPASS BYPASS MODE 5[15-16] BYPASS ADAPTOR REMOVED PHOTO-EYE BYPASSED 5[17-22] IDLE IN IDLE STATE 5[23-27] FAULTED MOTOR OFF 5[28-29] FAULTED AIR OFF 5[30-31] FAULTED FLUID OFF 6[00-09] FAULTED FILL MOTOR OVERLOAD TRIPPED 6[10-31] FAULTED TANK xx OVERFILL FAULT 7[00-09] FAULTED VALVE O/L TRIPPED FAULT 7[10-16] FAULTED VOLUME TRANSDUCER FAULT 7[17-31] FAULTED VOLUME SENSOR FAULT Owner: ICT Launch Management Page 4 of 14 Revision: 2.2
5 8[00-16] FAULTED VACUUM TRANSDRE FAULT 8[17-31] MAINT. ASSIST TANK xx OVERFILL FAULT 9[00-09] FAULTED BOOSTER EXTEND/EXTRACT FAULT 9[10-15] FAULTED ADAPTER CLAMP PRESS LOW 9[16-25] FAULTED ABS CPU FAULTS 9[26-31] SPARES SPARES 10[00-31] MAINT. ASSIST TANK xx LOW FAULT 11[00-15] FAULTED VACUUM SENSOR FAULT 11[16-31] SPARES VACUUM FAULTS/ALARMS 12[00-15] FAULTED PRESSURE SENSOR FAULT 12[16-31] FAULTED FILLOVER-PRESSURE FAULT 13[00-31] SPARES SPARES 14[00-15] FAULTED xxxnxx SHORTED SOLENOID FAULT 14[16-31] FAULTED xxxnxx OPENSOLENOID FAULT 15[00-31] FAULTED DNETNODE xx FAULT 16/17[0-31] FAULTED PFCS FAULTS EX. MAINT. ASSIST PFCS DRIVER'S FAULTS EX. MAINT. ASSIST PFCS SOL.RESPONSE ERROR EX. MAINT. ASSIST PFCS SOL.MESSAGE ERROR EX. MAINT. ASSIST PFCS SOL. MESSAGE RESP. TIMEOUT EX. MAINT. ASSIST PFCS UNSOL. RESPONSE ERROR EX. MAINT. ASSIST PFCS UNSOL. MESSAGE ERROR EX. MAINT. ASSIST PFCS UNSOL. MESSAGE RESP. TIMEOUT EX. MAINT. ASSIST PFCS NOCLIENT COMM DETECTED EX. MAINT. ASSIST PFCS ETHERNET SLOT ERROR EX. MAINT. ASSIST PFCS ETHERNET WCC IP ERROR EX. MAINT. ASSIST PFCS UNDEFINED STYLE RECEIVED 18[00-31] FAULTED E-NET COMMLOST TO CLX(xxx) FAULTS 19[00-10] ALARM STYLE CHANGED MANUALLY 19[11-15] FAULTED HMIxx COMMUNICATION LOST 19[16-19] STARVED BLOCKEDUP STREAM 19[20-23] BLOCKED DOWN BLOCKED DOWNSTREAM 19[24-31] ALARM PROCESSOR's ALARMS/CLx BATTERYLOW,.,etc Owner: ICT Launch Management Page 5 of 14 Revision: 2.2
6 20[00-15] FAULTED MODULES FAULTS 20[16-31] SPARES SPARES 21[00-31] QUALITY ALERT CYCLES FAULTS EX. QUALITY ALERT ADAPTOR VACUUM TEST CYCLE FAULT EX. QUALITY ALERT INITIAL PRES. CHECK CYCLE FAULT EX. QUALITY ALERT LEAKE TEST OVERALL TEST (P)ass/(F)ail EX. QUALITY ALERT VACUUM LARGE LEAK CYCLE FAULT EX. QUALITY ALERT VACUUM SMALL LEAK CYCLE FAULT EX. QUALITY ALERT FINAL VACUUM CYCLE FAULT EX. QUALITY ALERT VACUUM LEAK DECAY CYCLE FAULT EX. QUALITY ALERT FILL ABORT CYCLE FAULT EX. QUALITY ALERT FILL TIME EXCEEDED CYCLE FAULT EX. QUALITY ALERT STABALIZE TEAT (P)ass/(F)ail/(Z)NO TEST EX. QUALITY ALERT AIR TOLERANCE ALARMS EX. QUALITY ALERT AIR PRESSURIZATION TEST(P)ass/(F)ail/(Z)NO TEST EX. QUALITY ALERT FILL OVERPRESSURE CYCLE FAULT EX. QUALITY ALERT FILL VOL.< MINIMUM CYCLE FAULT EX. QUALITY ALERT/FAULTED PREMATURE PRESSURE FAULT EX. QUALITY ALERT/FAULTED HIGH CAR PRESSURE FAULT EX. QUALITY ALERT FILL VOL.> MAXIMUM CYCLE FAULT 22[00-01] MAINT. ASSIST PARAMETER CHANGES ADJUSTMENT/MODIFICATION 22[02-03] MAINT. ASSIST FLUID FILL PASS/FAIL-QUALITY ALERT 22[04-05] MAINT. ASSIST PARAMETER SCREEN NOTIFICATION/CHANGES USED BY PASSxxx 22[06-07] MAINT. ASSIST NOTIFICATION PASS. CHANGED 22[08-09] MAINT. ASSIST TIME COUNTER EXCEEDED LIMIT -MAINT. ACTIVITY 22[10-13] MAINT. ASSIST CALIBRATION CHECK/VERIFICATION VALUES CHANGED 22[14-15] MAINT. ASSIST FLUID PRESSURE SUPPLIES LOW-"UNDER SET POINT" 22[16-17] MAINT. ASSIST PORTABLE PUMPING STATION TOTES LOW 22[18-19] MAINT. ASSIST PORTABLE PUMPING STATION TOTES EMPTY 22[20-31] MAINT. ASSIST SPARES POWER 23[00-31] OFF/FAULTED/ALARM CIRCUIT BREAKERS/FUSES ALARMS 24[00-31] FAULTED SPARES Owner: ICT Launch Management Page 6 of 14 Revision: 2.2
7 25[00-31] FAULTED SPARES 7) PFCS (PLANT FLOOR COMMUNIATIONS SYSTEM) The device shall conform to PFCS Vendor Specifications: 1. The connection to PFCS shall be made via Ethernet (TCP/IP). (Must be made through a dedicated NIC, not through a switch or router internal to the machine) 2. Have a unique IP address assigned by the plant. 3. Have a unique Machine ID(s) and DCNO Port(s) assigned by the Plant ICT group. 4. Use PFCS group-certified communication software (a combination of the hardware, firmware and software). No device will be connected to the FCA US LLC network until this certification process has been completed. 5. If operation requires unsolicited data downloads from PFCS (QAS), it must receive this download on a separate port. One port sends data to PFS and VIN requests to AVI, the other port receives unsolicited QAS VIN and Style data. 6. Utilize the USD communications driver. Owner: ICT Launch Management Page 7 of 14 Revision: 2.2
8 8) PFS (PERFORMANCE FEEDBACK SYSTEM) Every machine will be tested at the OEM's facility for its ability to communicate to PFS before delivery to the assembly plant. Please contact your ICT ASLM representative for more information. DATA FORMAT Start End Length Description Format Machine ID, PC01, etc Ack/Nak Area (spaces) Message Sequence Number (refer to PFCS vendor specs) Request Type (0002) Data Byte Count (position 22 to the end, exclude <CR>) Number Of Records In Block (0001) Filler Spaces Last 6 Of VIN Last 6 Of Track Number If VIN Is Zero Date and Time (YYMMDDHHMMSS) Leak Test Overall (P)ass/(F)ail (P/F) Fill (Vacuum 1) Test (P)ass/(F)ail/(Z)No Test (P/F/Z) Fill (Vacuum 1) Actual Value (inh2o) (x.xxx) Fill (Vacuum 1) High Tolerance (x.xxx) Fill (Vacuum 1) Low Tolerance (x.xxx) Fill (Vacuum 1) Time (xx.x) Fill with Monitor (Vacuum 2) Test (P)ass/(F)ail/(Z)No Test (P/F/Z) Fill with Monitor (Vacuum 2) Actual Value (inh2o) (x.xxx) Fill with Monitor (Vacuum 2) High Tolerance (x.xxx) Fill with Monitor (Vacuum 2) Low Tolerance (x.xxx) Fill with Monitor (Vacuum 2) Time (xx.x) Isolate Test (P)ass/(F)ail/(Z)No Test (P/F/Z) Isolate Actual Value (inh2o) +/ (x.xxx) Isolate High Tolerance +/ (x.xxx) Isolate Low Tolerance +/ (x.xxx) Owner: ICT Launch Management Page 8 of 14 Revision: 2.2
9 Isolate Time (xx.x) Stabilize Test (P)ass/(F)ail/(Z)No Test (P/F/Z) Stabilize Actual Value (inh2o) +/ (x.xxx) Stablize High Tolerance +/ (x.xxx) Stablize Low Tolerance +/ (x.xxx) Stabilize Time (xx.x) Leak Test (P)ass/(F)ail/(Z)No Test (P/F/Z) Leak Test Actual Value (sccm) +/ (xxx.xx ) Leak Test High Tolerance +/ (xxx.xx ) Leak Test Low Tolerance +/ (xxx.xx ) Leak Test Time (xx.x) Exhaust Time xx.x Exhaust Value +/ (x.xxx) Overall Cycle Time From Cycle Start to Exhaust Complete (Sec) (xx.x) Dealta Pressure Value (inh2o) +/ (x.xxx) Temperature Reading at end of Test Time (F) (xx.x) Temperature Change from Start to End of test (F) (xx.x) Future Test (P)ass/(F)ail/(Z)No Test (P/F/Z) Future Test Actual Value (sccm) +/ (xxx.xx ) Future Test High Tolerance +/ (xxx.xx ) Future Test Low Tolerance +/ (xxx.xx ) Machine Fault During Cycle (Y)es/(N)o (Y/N) Machine Fault Code (xxx) Console Number (1,2,3) or (A,B,C) (x) Leak Test Tool Used (1=non caplesee; 2=caplesss) (x) Operator Abort During Cycle (Y)es/(N)o (Y/N) Owner: ICT Launch Management Page 9 of 14 Revision: 2.2
10 Late Start (Past Start Zone) (Y)es/(N)o (Y/N) End of Travel Actuated During Cycle (Y)es/(N)o (Y/N) (H)and Scanner/(M)anual VIN entry/(q)as (x) Internal Program Style Selected (xx) Broadcast/QAS Download Style Received (xx) 9) QAS DOWNLOAD QAS Downloads will be sent unsolicited on the machine ID ending with a letter (example: DF0A). A handheld scanner shall be used as a backup device should QAS not be functioning. The handheld scanner will make its request, and gets its reply, on the machine ID ending with a number (example: DF01). This is a sample QAS style download for a Leak Test machine: Start End Len Field Name Machine ID s: DF0A, DF0B Spaces Description Message Sequence Number Refer to PFCS vendor specs Data byte count Position 22 to end, exclude <cr> Aa Broadcast Message Type Code Bc Last 6 of the VIN Label Barcode Vehicles status B=Model year C=plant code Owner: ICT Launch Management Page 10 of 14 Revision: 2.2
11 Track Sequence number Style download to device 00 Invalid style plant specific engine type 90 No Op condition Owner: ICT Launch Management Page 11 of 14 Revision: 2.2
12 10) ACCEPTANCE CRITERIA This is a summary of the ICT acceptance criteria required of the vendor; please refer to the FCA US LLC Do s and Don ts for more detail. 1. PFCS certification must be completed before: The device can be attached to the plant network PFS data certification can be conducted 2. PFS certification must be complete before the device ships to the plant. 3. AVI standard point certification must be followed if an AVI barcode reader is used; this includes testing at the OEM prior to equipment shipping. 4. FIS certification is required. 5. The following line items are examples of what must be tracked in the OEM timeline: 1. ICT Hardware Design 2. ICT Software Design 3. ICT Communications Testing At FCA US LLC (PFCS) 4. ICT System Testing At OEM (PFS Functionality) 5. ICT System Testing at FCA US LLC Assembly Plant Owner: ICT Launch Management Page 12 of 14 Revision: 2.2
13 DOCUMENT REVISIONS Doc. Rev. Date Doc. Rev. Number Doc. Rev. Description Section No. Revised 5/4/ Change Chrysler to FCA US LLC All Added step 3 in section 7. 7 Updated PFS Data String 8 6/26/ Added FIS bit map 6 Owner: ICT Launch Management Page 13 of 14 Revision: 2.2
14 Owner: ICT Launch Management Page 14 of 14 Revision: 2.2
BRAKE Fill Machines ICT Requirements
Manufacturing Engineering General Assembly (MEGA.ICT-8519-02_A.01) BRAKE Fill Machines ICT Requirements 1) OVERVIEW This document summarizes the current ICT requirements for new machines to be purchased
More informationWHEEL LUG NUT MACHINES
1) OVERVIEW This document summarizes the current ITM requirements for new Wheel Lug Nut Torque Machines to be installed in Chrysler Assembly Plants. This document is managed by the ITM Assembly System
More informationBook of Implementation Guidelines PFCS Driver Integration for ControlLogix
Advance Manufacturing Engineering Book of Implementation Guidelines AMS 0220 Section 11.3.1 Revision Date: 08/01/07 Page 1 of 25 Revision: 1.3 Proprietary Notice This document comprises legally protected
More informationAutomatic Vehicle Identification System (AVI) Training Manual
Automatic Vehicle Identification System (AVI) Training Manual Chapter A1: Acronyms Owner: APICS Page 1 of 7 Revision: 1.1 TABLE OF CONTENTS A ACRYONYMS...4 Owner: APICS Page 2 of 7 Revision: 1.1 Document
More informationAutomatic Product Identification and Control Systems
Automatic Product Identification and Control Systems Presented by: Larry Vavro, Manager APIC Systems Larry Walker, Senior Manager Assembly Systems Processes 3/12/2002 APIC Systems 1 APIC Systems Topics
More informationBook of Implementation Guidelines AVI/VMS DeviceNet Reader Installation & Configuration for PLC-5
Advance Manufacturing Engineering Book of Implementation Guidelines AVI/VMS DeviceNet Reader Installation & Configuration for PLC-5 AMS 0220 Section 14.2.4 Revision Date: 08/01/07 Page 1 of 44 Revision:
More informationBook of Implementation Guidelines PFCS Vendor Specification
Manufacturing Engineering PFCS Vendor Specification Revision Date: 07/25/11 Page 1 of 138 Revision: 2.4 Proprietary Notice This document comprises legally protected subject matter proprietary to Chrysler,
More informationChapter 5 QAS Setup and Configuration
Chapter 5 QAS Setup and Configuration In This Chapter Overview QAS PLC-5 Tracking Image Application Installation and Configuration Incremental Encoder Configuration SoftLogix5 Setup and Configuration Configuration
More informationBook of Implementation Guidelines PFCS Vendor Specification
Advance Manufacturing Engineering Book of Implementation Guidelines AMS 0220 Section 11.1.1 Revision Date: 08/01/07 Page 1 of 102 Revision: 2.3 Proprietary Notice This document comprises legally protected
More informationAutomatic Vehicle Identification System (AVI) Training Manual
Automatic Vehicle Identification System (AVI) Training Manual Chapter 7: Supervisory User Interface Owner: APICS Page 1 of 50 Revision: 1.34 TABLE OF CONTENTS 7 SUPERVISORY USER INTERFACE...4 7.1 APIC
More informationMistake Proofing Certification Document
Mistake Proofing Certification Document Owner: Gerald Stocker Page 1 of 7 Revision: 1.1 TABLE OF CONTENTS 1 INTRODUCTION...4 1.1 DOCUMENT PURPOSE...4 1.2 INTENDED USERS...4 1.3 SUPPORTING DOCUMENTATION...4
More informationModbus Register Map: InRow ACRD60x / ACRC60x
Modbus Map: InRow ACRD60x / ACRC60x Notes: 1. 16-bit registers (INT16, UINT16, ENUM) are transmitted MSB first (i.e., big-endian). 2. INT32 and UINT32 are most-significant word in n+0, least significant
More informationAddendum to Verbatim Gateway Owner's Manual How to configure a Verbatim EtherNet/IP with RSLogix 5000
Addendum to Verbatim Gateway Owner's Manual How to configure a Verbatim EtherNet/IP with RSLogix 5000 Addendum 1.1 Page 1 (25) Document history Revision Date Description Author 1.00 2003-04-16 Document
More informationPoint Level Transmitters. Pointek CLS200 (Standard) Functional Safety Manual 02/2015. Milltronics
Point Level Transmitters Pointek CLS200 (Standard) Functional Safety Manual 02/2015 Milltronics Introduction 1 General safety instructions 2 Pointek Level Instruments Device-specific safety instructions
More informationHART USER GUIDE FOR GASSONIC OBSERVER-H ULTRASONIC GAS LEAK DETECTOR
HART USER GUIDE FOR GASSONIC OBSERVER-H ULTRASONIC GAS LEAK DETECTOR This page intentionally left blank. HART USER GUIDE FOR GASSONIC OBSERVER-H ULTRASONIC GAS LEAK DETECTOR HART User Guide for Gassonic
More informationMANUFACTURING TECHNICAL INSTRUCTIONS - SAFETY. Subject: Control Reliability for Machinery & Equipment
DAIMLERCHRYSLER MANUFACTURING TECHNICAL INSTRUCTIONS - SAFETY Subject: Control Reliability for Machinery & Equipment ISSUE DATE: January 3, 2005 EFFECTIVE DATE: January 31, 2005 REVIEW DATE. June 26, 2007
More informationIntroduction. Upon completion of Basics of PLCs you should be able to: Identify the major components of a PLC and describe their functions
Table of Contents Introduction...2 PLCs...4 Number Systems...8 Terminology...14 Basic Requirements...23 S7-200 Micro PLCs...28 Connecting External Devices...39 Programming a PLC...41 Discrete Inputs/Outputs...49
More informationINSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.
INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road, Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Revision Date: 9-11-08 Applications: Simplex,
More informationCPC. Composite Processing Control For Windows. Software Operations Manual. Copyright 2009, ASC Process Systems Documentation revision: 2/16/2009
CPC Composite Processing Control For Windows Software Operations Manual Copyright 2009, ASC Process Systems Documentation revision: 2/16/2009 CPC Operations Manual Index Page #1-1 1. STARTING CPC...1-1
More informationto monitor and control manufacturing processes
simply THE Best technology to monitor and control manufacturing processes Standardize Testing Across The Plant Flexible Monitoring Platform sigpod is an in-station process monitoring platform that uses
More informationLegacy BaseStation 3200 Specification Sheet
The with V12.34 firmware from Baseline is an advanced smart controller that is ideal for everything from high-end residential properties to large commercial projects. The comprehensive features of the
More informationCAS Veeder TLS 300, 350, 450. Gateway
CAS-2700-02 Veeder TLS 300, 350, 450 (RTU and TCP) and BACnet and HTML Gateway Description The Veeder Serial Driver allows the Gateway to poll Veeder TLS Panel s for status, real time and configuration
More informationBaseStation 1000 Specification Sheet
BaseStation 1000 The BaseStation 1000 is part of Baseline s family of intelligent irrigation controllers. It is easier to use and program than any other controller on the market, and yet it still provides
More information1. Introduction. Be sure to read the release notes in section 10 before operating the Unit.
1. Introduction This manual describes the ways of configuring and monitoring the operation of the PROFINET IO Controller CJ1W-PNT Sample Version V0.00 V67.06 V0.00 (Internal release V6.29). Be sure to
More informationElectrical Demand Specification (Reference SOP: )
Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3
More informationSR5 Serial Protocol - Issue 1.6
cctalk bus SR5 Serial Protocol - Issue 1.6 This document is the copyright of Money Controls Ltd and may not be reproduced in part or in total by any means, electronic or otherwise, without the written
More information1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.
I P MAC AD D RE S S Getting Started This is a brief document designed to quickly get you started setting up your valve manifold with an integrated Numatics G2-2 Series EtherNet/IP communication node. 1)
More informationMODEL IR5500 Infrared Open Path Gas Detector HART Field Device Specification
MODEL IR5500 Infrared Open Path Gas Detector HART Field Device Specification The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the
More informationMODELS: STEAM FIRED YPC-ST-14SC & YPC-ST-16SL Thru YPC-ST-19S
Supersedes: 155.19-W1 (407) Form: 155.19-W1 (812) TWO-STAGE ABSORPTION CHILLERS WIRING DIAGRAMS CONTRACTOR ORDER NO. JCI CONTRACT NO. JCI ORDER NO. PURCHASER JOB NAME LOCATION ENGINEER REFERENCE DATE APPROVAL
More informationDELTA CONTROLS CORPORATION
HART Field Device Specification: DELTA CONTROLS CORPORATION MODEL 173 REV 3.0 Document 00-17335, rev. A Initial release: 2 January 2019 Current release: 2 January 2019 Author: Ted Keys Delta Controls Corporation
More informationIntegration of In-Sight with AB PLCs running RSLogix
Integration of In-Sight with AB PLCs running RSLogix Author: Samantha Frost Published: August 11, 2017 Revision: 1.0 Contents Communicate with a Rockwell ControlLogix PLC... 4 Integration with RSLogix
More information1.0 Introduction. 1.1 General
1.0 Introduction The Linac Coherent Light Source (LCLS) project at the Stanford Linear Accelerator Center (SLAC) is intended to create an x-ray free electron laser source of unprecedented brightness and
More informationAEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE
AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE Thank you for purchasing a TSI AeroTrak Portable Airborne Particle Counter (particle counter). This guide will
More informationMicroNet TMR Control System
Product Specification 03363 (Rev. C) MicroNet TMR Control System Applications The MicroNet TMR (triple modular redundant) controller is a state-of-the-art digital control platform designed to reliably
More informationRemoval of Hardware ESD, Independent of Safety Logic Solver
Removal of Hardware ESD, Independent of Safety Logic Solver by Sam Roy Executive summary This is a discussion to remove independent hardware based Emergency Shutdown for Logic Solver as identified in ANSI/ISA-84.00.01-2004,
More informationObserve all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.
MCD DeviceNet Module Instructions Important User Information INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Important User Information Observe all necessary safety precautions
More informationAccord Builder. User Guide
User Guide Document: V 3.6 User Guide R01 V3.6 User Guide R01 Page 1 of 110 Table of Contents 1 Introduction... 7 2 General Summary and Definitions... 8 2.1 Accord Platform and Plant... 8 2.2 PLC Control
More informationMarch 21, Re: Life Cycle Change Notification FloBoss 407 and ROC 300 Series. ROC 300 and 407 Customers,
March 21, 2014 Re: Life Cycle Change Notification FloBoss 407 and ROC 300 Series ROC 300 and 407 Customers, This letter is to inform you that spare and replacement parts related to the ROC 300 Series and
More informationApplications of Programmable Logic Controllers DG31 34
Applications of Programmable Logic Controllers DG31 34 Purpose Unit purpose: This Unit is designed to introduce candidates to Programmable Logic Controllers (PLCs) and enable them to understand how PLCs
More informationEthernet DHX Driver Help Ethernet DHX Driver for Allen-Bradley TCP/IP Networks
Ethernet DHX Driver Help Ethernet DHX Driver for Allen-Bradley TCP/IP Networks Version 9 ETHERNET DHX DRIVER HELP Ethernet DHX Driver for Allen-Bradley TCP/IP Networks Version 9 Copyright 1994-2017, Cyberlogic
More informationFisher FIELDVUE DVC6200p Digital Valve Controller Device Setup and Accessing Communication and Calibration using Siemens SIMATIC Manager/PDM
Instruction Manual Supplement Fisher FIELDVUE DVC6200p Digital Valve Controller Device Setup and Accessing Communication and Calibration using Siemens SIMATIC Manager/PDM Contents Related Documents...
More informationCAS Veeder TCP - TLS 300, 350, 450. Gateway
CAS-2700-03 Veeder TCP - TLS 300, 350, 450 Modbus (RTU and TCP) and BACnet and HTML Gateway Description The Veeder TCP Driver allows the Gateway to poll Veeder TLS Panel s for status, real time and configuration
More informationInstall the DeviceNet Module using the following procedure:
Installation INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Installation Install the DeviceNet Module using the following procedure: 1. Remove control power and mains supply from
More informationDeviceNet Module. User Manual. 1 Important User Information. 2 Installation
User Manual 1 Important User Information Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. It is the installer's
More informationWW Celerity Applications Engineering Mass Flow Controller Troubleshooting Guide
WW Celerity Applications Engineering Mass Flow Controller Troubleshooting Guide Troubleshooting Manual for Mass Flow Controllers 1 199-001-0009 REV A TABLE OF CONTENTS Troubleshooting Guide for Digital
More informationMPU-32 DEVICENET INTERFACE
3714 Kinnear Place Saskatoon, SK Canada S7P 0A6 Ph: (306) 373-5505 Fx: (306) 374-2245 www.littelfuse.com/relayscontrols INTERFACE Revision 8-A-050914 QUICK SETUP Use the operator interface to access the
More informationPLC 4 PRIMARY SEDIMENTATION SYSTEM SCADA SYSTEM OPERATION MANUAL. Revision 1.0 May 15, 2006
PLC 4 PRIMARY SEDIMENTATION SYSTEM SCADA SYSTEM OPERATION MANUAL Revision 1.0 May 15, 2006 PLC 4 PRIMARY SEDIMENTATION SYSTEM SCADA SYSTEM OPERATION MANUAL Revision 1.0 May 15, 2006 Table of Contents 1
More informationDeckblatt. APL Operator Guide SIMATIC PCS 7. Application description June Applikationen & Tools. Answers for industry.
Deckblatt SIMATIC PCS 7 Application description June 2011 Applikationen & Tools Answers for industry. Industry Automation and Drive Technologies Service & Support Portal This article is taken from the
More informationShown with terminal block Supports diagnostic point fault contacts in the logic program
GFK-2482F PACSystems* RX3i Isolated Analog Input Modules, IC695ALG106-EA, IC695ALG112-EA Product Description Isolated Analog Voltage/Current Input module IC695ALG106 provides 6 isolated input channels.
More informationMPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice
MPCR Series DeviceNet Technical Manual Table of Contents MPCR Series Introduction... 3 Product Overview... 3 About DeviceNet... 4 Overview... 4 MPCR DeviceNet Features... 4 Cabling and Drop Line Lengths
More informationD Issue D Original. Instruction Manual. Micro Tool Interface
Instruction Manual D373-60-880 Issue D Original Micro Tool Interface Description SPI Micro-TIM MCM Micro-TIM TEL Micro-TIM SEMI E73 Micro-TIM LAM Alliance Micro-TIM Novellus C3 Micro-TIM Hitachi Micro-TIM
More informationUse of device diagnostics.
Use of device diagnostics. Hans Stevens, Shell Global Solutions PTE/EPAC Process Automation, Control, and Optimization (PACO) 2011 Copyright of Royal Dutch Shell plc Agenda Agenda Topic Shell s Vision
More informationMCD 200 Series. MCD 200 DEVICENET Module OPERATING INSTRUCTIONS. MCD 200 DEVICENET Module. Order Code: 175G9002. Adjustment.
Installation OPERATING INSTRUCTIONS Order Code: 175G9002 Adjustment 35 mm (1.38 inches) Control power and mains supply must be removed from the MCD 200 before attachment or removal of an accessory module.
More informationSensors and Systems. Short Form. that protect your plant...
Sensors and Systems Short Form that protect your plant... About us What is Hansford Sensors? At Hansford Sensors, we design, develop and manufacture a wide range of high performance industrial accelerometers,
More informationSC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703
SC2000 INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Operating Program Revision: 10 Revision Date: 1-9-12 STATION
More informationUSER MANUAL. Modbus IHP24-A IHP24-AF IHP24-B IHP24-BF IHP24-F IHP24-I 1/26
USER MANUAL Modbus IHP24-A IHP24-AF IHP24-B IHP24-BF IHP24-F IHP24-I 1/26 Table of contents 1 General... 3 1.1 Safety instructions... 3 2 Purpose... 4 3 Specifications... 5 3.1 Electrical specifications
More informationTroubleshooter Quick Reference Guide
Troubleshooter Quick Reference Guide March 2008 EAZ0025B29B Rev. C Trademarks Acknowledgement Snap-on, Scanner, and Fast-Track are trademarks of Snap-on Incorporated. All other marks are trademarks of
More informationOperator Manual for Profibus
PROCESS ANALYSERS SERVOPRO MultiExact Operator Manual for Profibus Part Number: Revision: Language: 05410007A 0 UK English This page intentionally blank LIST OF CONTENTS Section Page 1. DESCRIPTION AND
More informationOperating Instructions COROS OP7 GB
Operating Instructions COROS OP7 GB Table of Contents Page 1 Display OP7 - Main Functions... 3 1.1 Description of Softkey, Function and System Buttons... 3 1.2 Displaying Text Variables... 5 2 Switching
More informationMPU-32 ETHERNET/IP INTERFACE
3714 Kinnear Place Saskatoon, SK Canada S7P 0A6 Ph: (306) 373-5505 Fx: (306) 374-2245 www.littelfuse.com/relayscontrols ETHERNET/IP INTERFACE Revision 0-A-051314 Copyright 2014 Littelfuse Startco All rights
More informationElectrical & Controls. September 28, 2017
Electrical & Controls September 28, 2017 What is a PLC? Programmable Logic Controller Definition Industrial computer based control system that continuously monitors the state of input devices and makes
More informationOperating Instructions EB 8388 EN. Series 373x Positioners. EXPERT + Valve Diagnostics
Series 373x Positioners EXPERT + Valve Diagnostics Fig. 1 Valve diagnostics with SAMSON TROVIS-VIEW Operator Interface, e.g. for Type 3730-3 Positioner Operating Instructions EB 8388 EN Firmware version
More informationFor normal duty, design the VFD voltage level at 480 Volt, 3 Phase, 60 Hertz. (In Canada, 600 Volt, 3 Phase, 60 Hertz.)
Introduction The Variable Frequency Drive Design Guidelines provides design criteria and specifications used in the procurement and application of variable frequency drives (VFDs). Table of Contents 1.
More informationUnderstanding printer messages
The operator panel displays messages describing the current state of the printer and indicates possible printer problems you must resolve. This topic provides a list of all printer messages, explains what
More informationEthernet/IP Module. User Manual. Contents
User Manual Contents 1 Important User Information... 2 2 Installation... 3 3 Connection... 4 4 Device Configuration... 5 5 Operation... 8 6 Packet Structures... 9 7 Network Design... 18 8 Specifications...
More informationOPERATING INSTRUCTIONS MCD
Installation OPERATING INSTRUCTIONS Order Code: 175G9001 If the Profibus network fails, the module will leave data exchange mode after the network watchdog timeout period has expired. The Master configuration
More informationTA Instruments New Features in TAM Air Assistant TM and TAM Assistant TM Software
TA Instruments in TAM Air Assistant TM and TAM Assistant TM Software Notice The material contained in this manual, and in the online help for the software used to support TA Instruments products, is believed
More informationQuantum HD Release Notes
Quantum HD Release Notes OS Version 10.17 Released 7-14-2014 To upgrade to OS version 10.17 directly the current OS version must be 10.13 through 10.16. To check the current OS version on the Quantum HD
More informationPD 527 Valve Control Module PD Series 600. Product Data Sheet February 2015 SD E06
PD 527 Valve Control Module PD Series 600 Product Data Sheet February 2015 SD 8719-2E06 PD 527 Valve Control Module February 2015 Introduction The PD 527 Valve Control Module is specially designed to control
More informationEtherNet /IP User Guide
EtherNet /IP User Guide Trademark Notices Comtrol, DeviceMaster, and PortVision are registered trademarks of Comtrol Corporation. ControlLogix, PLC-5 and Rockwell Automation are registered trademarks of
More informationPOWR-GARD Motor Protection PGR-6200 SERIES Motor Protection System PGR-6200 DEVICENET INTERFACE
POWR-GARD Motor Protection PGR-6200 SERIES Motor Protection System PGR-6200 INTERFACE MAY 21, 2009 REVISION 1 QUICK SETUP Use the operator interface to access the Setup Hardware Network Comms menu. Set
More informationRevision. MOVIPRO with EtherNet/IP or Modbus TCP Fieldbus Interface * _1017*
Drive Technology \ Drive Automation \ System Integration \ Services *22497064_1017* Revision MOVIPRO with EtherNet/IP or Modbus TCP Fieldbus Interface Edition 10/2017 22497064/EN SEW-EURODRIVE Driving
More informationVARIABLE SPEED BOOSTER SYSTEMS AURORA INTELLIBOOST WITH INTELLIMANAGER. Distributed by Flow-Tech Industries
AURORA INTELLIBOOST WITH INTELLIMANAGER VARIABLE SPEED BOOSTER SYSTEMS Certified to NSF/ANSI 61-G AURORA INTELLIBOOST Variable Speed Booster System Take A Leap Toward Technology The IntelliBoost Variable
More informationCopyright: December 2017 Nidec Issue: E
General Information The manufacturer accepts no liability for any consequences resulting from inappropriate, negligent or incorrect installation or adjustment of the optional parameters of the equipment
More informationEconomizer Fault Detection and Diagnostics (FDD) for Built-Up Air Handlers Draft Report
Economizer Fault Detection and Diagnostics (FDD) for Built-Up Air Handlers Draft Report Draft Code Language Last Updated: March 2017 1. INTRODUCTION The California Statewide Utility Codes and Standards
More informationEIP ET200 Configuration Tool User Reference Guide
EIP ET200 Configuration Tool User Reference Guide Document Edition: 1.1.2.0 Document CI#: 6214 User Reference Guide EIP ET200 Configuration Tool Document Edition: 1.1.2.0 Date: May 7, 2014 This document
More informationTHE StarSCAN FLASH FILES FOR THIS BULLETIN ARE AVAILABLE VIA THE INTERNET. StarSCAN SOFTWARE LEVEL MUST BE AT RELEASE 9.04 OR HIGHER.
NUMBER: 18-001-09 GROUP: Vehicle Performance DATE: January 21, 2009 This bulletin is supplied as technical information only and is not an authorization for repair. No part of this publication may be reproduced,
More informationMicro-Master 4500 Series Controllers
Micro-Master 4500 Series Controllers Application Micro-Master controller used for horticultural and agricultural applications with Filter Flushing and Chemical Fertiliser Injection Programs 16 and 25 station
More informationObserve all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.
MCD Profibus Module Instructions Important User Information Installation Instruction: MCD Profibus Module Order Code: 175G9001 1. Important User Information Observe all necessary safety precautions when
More informationRosemount Transmitter Diagnostics Reduce Maintenance Costs
Rosemount Transmitter Diagnostics Reduce Maintenance Costs ROSEMOUNT TRANSMITTER DIAGNOSTICS... Reduce the Necessity of Trips to the Field by 85% Eliminate Ghost Chasing by Checking Transmitter Diagnostics
More informationInstallation Instructions
Installation Instructions 1771-SDN/B DeviceNet Scanner Module Installation Instructions 1 (Catalog Number 1771-SDN/B) Use this document as a guide to installing your 1771-SDN/B Scanner Module. Before you
More informationSCADA System Specification. Vantage Pipeline Project # May 2013
SCADA System Specification Vantage Pipeline Project #201011 May 2013 Revision 0 Issued for Approval May 24, 2013 TABLE OF CONTENTS REVISION HISTORY:...2 1 PROJECT OVERVIEW...3 2 SCOPE AND PURPOSE...4 3
More informationExercise 5-1. Electrical Circuit and Panel EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Detailed electrical schematic
Exercise 5-1 Electrical Circuit and Panel EXERCISE OBJECTIVE When you have completed this exercise, you will be familiar with the trainer electrical schematic and components. DISCUSSION OUTLINE The Discussion
More informationSupplemental Manual for Brooks DeviceNet MFC/RTs
Installation and Operation Manual Supplemental Manual for Brooks DeviceNet MFC/RTs For SLA7000 Series Installation and Operation Manual Essential Instructions Read this page before proceeding! Brooks Instrument
More informationComplimentary Reference Material
Complimentary Reference Material This PDF has been made available as a complimentary service for you to assist in evaluating this model for your testing requirements. TMG offers a wide range of test equipment
More informationAutomatic Vehicle Identification System (AVI) Training Manual
Automatic Vehicle Identification System (AVI) Training Manual Chapter 3: Plant Floor Vehicle Identification Owner: APICS Page 1 of 48 Revision: 1.1 TABLE OF CONTENTS 3 PLANT FLOOR VEHICLE IDENTIFICATION...4
More informationLDV Communications Specification
LDV6x-0308m - 1/22 Models: LDV6S and LDV6U LDV Communications Specification 2/19/2002 Rev 0.1 Created document draft JDS 2/22/2002 Rev 0.11 Added instructions on the use of Broadcast Messages JDS 3/18/2002
More informationRelease Date: September 4, 2014
MV1DU User s Guide Release Date: September 4, 2014 Use of the MV1DU Diagnostic System requires an active license agreement or MV-1 Dealer Agreement. For information on obtaining a license, please email
More informationSC100 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:
SC100 INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: Website: (407) 299-3825 www.mpelectronics.com Operating Program Revision: 1 Revision Date: 4-2-18
More informationSeries SD6 Limit with DeviceNet
Series SD6 Limit with DeviceNet DeviceNet Communications This appendix describes the DeviceNet protocol as it is implemented in the Series SD6 controller. It primarily describes the objects and attributes
More informationEtherNet/IP with Applied Motion Drives
EtherNet/IP with Applied Motion Drives EtherNet/IP with Applied Motion Drives Jeff Kordik CTO Applied Motion Products, Inc. 1 92-5 Rev. B Applied Motion Products Contents Overview of EtherNet/IP...3 EtherNet/IP
More informationROC Plus Protocol. Specification Manual. Form A6127. Flow Computer Division. Part Number D301180X0012 January 2007
Form A6127 Part Number D301180X0012 January 2007 ROC Plus Protocol Specification Manual Flow Computer Division Website: www.emersonprocess.com/flow Revision Tracking Sheet January 2007 This manual is periodically
More informationIntech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.
Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-A8VI Installation Guide. The 2300 series stations are designed to
More informationFast, accurate, easy to integrate and easy to maintain leak testing
Fast, accurate, easy to integrate and easy to maintain leak testing Process Signature Verification for Leak Test: Advanced software High accuracy Industry-leading serviceability Part traceability Standard
More informationMODBUS TCP MODULE INSTRUCTIONS. for use with WSIQ2/WSE
INSTRUCTIONS MODBUS TCP MODULE for use with WSIQ2/WSE WorldWide Electric Corporation Phone: 1-800-808-2131 Fax: 1-800-711-1616 www.worldwideelectric.net Product Compatibility This communications module
More informationAddendum to Catalyst Owner's Manual How to configure a Catalyst EtherNet/IP with RSLogix 5000
Addendum to Catalyst Owner's Manual How to configure a Catalyst EtherNet/IP with RSLogix 5000 Addendum 1.1 Page 1 (20) Document history Revision Date Description Author 1.00 2014-3-17 Document created
More information1791 Analog Block I/O Input/Output Modules User Manual
User Manual Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary
More informationAddendum to Verbatim Gateway Owner's Manual. Gateway Ethernet Module Setup. Version 5.0
Addendum to Verbatim Gateway Owner's Manual Gateway Ethernet Module Setup Version 5.0 Revision History Rev # Description Author/Editor Date 3 Draft. Re-write of 2.0 Davey Hudson 4/10/2015 4 Draft. Re-write
More informationDF FA SE. SIPLUS RIC IEConS7. File Transfer Version V1.6
DF FA SE SIPLUS RIC IEConS7 File Transfer Version V1.6 Functional description File Transfer DF FA SE Safety instructions Warning notices These Operating Instructions contain information that you should
More informationDocuments: 1 QAS Summary Guide. 2 QAS Plant Journal. 3 QAS Plant User Guide. 4 QAS Reference Guide
Documents: 1 QAS Summary Guide 2 QAS Plant Journal 3 QAS Plant User Guide 4 QAS Reference Guide 5 QAS Support Team Plant Installation/Update Checklist 6 QAS Support Team Test Checklist 7 QAS Simulation
More information