Digital Panel Meters Modular Indicator and Controller Type USC-DIN

Size: px
Start display at page:

Download "Digital Panel Meters Modular Indicator and Controller Type USC-DIN"

Transcription

1 Digital Panel Meters Modular Indicator and Controller Type USCDIN Front protection degree: IP 20 Linearization of V and A inputs up to 6 points Multiinput modular signal s conditioner 0.% RDG basic accuracy TRMS AC current and voltage measurements AC/DC current measurements; selectable full scales (200µA to 5A) AC/DC voltage measurements; selectable full scales (200mV to 500V) C or F temperature measurements (Pt , Ni00, TC JKSTE) Resistance measurements; selectable full scales (20Ω to 20kΩ) Dual rate, speed, frequency and period measurement (0.00Hz to 50kHz) Up to 4 independent alarm setpoints (optional) 20mA/0VDC analog output (optional) Serial port RS485 or RS232 (optional) MODBUS, JBUS communication protocol Product Description µpbased signal conditioner, for current, voltage, temperature, resistance, rate, frequency, speed and period measurements. Measuring ranges and functions easily programmable from the PC by means of optional Usc Soft software available on request. UscSoft includes programming, display and minmax functions. Conditioner housing for DINrail mounting with front protection degree: IP 20. All displaying and programming data are referred to UscSoft. How to order Model Slot A Slot B Slot C Slot D Slot E Options How to order USC XXX XX XX XX X XX UscSoftkit UscSoftkit: software plus communication cable for programming USC by means of PC. UscSoft: software for programming USC by means of PC, downloadable from Type Selection Slot A (measuring inputs) Slot B (communication) Slot C (communication and alarm) Slot D (communication) LSX: LSE/ LSF: HSX: TRX: TF: TF2: signal inputs: mA ; V signal inputs: AUX: mA ; V signal inputs: 0.225A ; V signal inputs: TC temperature probes (JK STE, Pt ) and resistance ( kΩ) 0.00Hz to 50kHz for DC signals: PNP, NPN, NAMUR, TTL, free of voltage, contacts, voltages up to 4VDC 0.00Hz to 50kHz for AC signals: pickup, voltages up to 500VAC XX: SX: SY: None Serial port RS485 Serial port RS232 (*): The two analogue outputs cannot be used at the same time. It is possible to plug in only one module by signal conditioner. XX: None R: Single relay output, (AC8AAC, 250VAC) R2: Dual relay output, (AC8AAC, 250VAC) R4: Dual relay output, (AC8AAC, 250VAC) dual open collector output (NPN, 00mA) R5: 4 Relay outputs (AC 5AAC, 250VAC) AV(*): Single analogue output: 0 to 20mA DC and 0 to 0V DC XX: None AV(*): Single analogue output, 0 to 20mA DC and 0 to 0V DC Slot E (power supply) H: 90 to 260V AC/DC L: 8 to 60V AC/DC 3: 0 to 28V DC Options XX: TX: None Tropicalization Specifications are subject to change without notice USC DIN DS ENG

2 Input specifications Analogue inputs BQ LSX module BQ LSE/LSF module BQ HSX module BQ TRX module BQ TRX module BQTF module BQTF2 module Digital inputs Number of inputs Use Contact reading signal Close contact resistance Open contact resistance Insulation Channels and variable, ma and V, ma and V AUX, A and V, temperature, resistance 2, frequency 2, frequency Incl. in the measuring module (voltagefree) keypad lock Display hold Reset of latch alarms BQ xxx: <0.mA, <3,5V DC BQ LSE/BQ LSF: <2.5mA, <4V DC BQTF: <6mA, <7VDC BQTF2: <0.25mA, <3VDC Max kω Min 500kΩ(BQTFx: 00kΩ) Noninsulated Accuracy (display, RS485) See table Measuring accuracy, temperature drifts and minimummaximum indications Additional errors Humidity 0.3% RDG (BQTFx: 0.05%), 60% to 90% R.H. Input frequency 0.4% RDG, 62 to 440 Hz Magnetic field 0.5% RDG (BQTFx: 400 A/m Temperature drift Sampling rate Display refresh time See table Measurement accuracy, temperature drifts, and max/min indications Hz (escl. BQTFx) Hz (escl. BQTFx) Max and min indication Measurements Coupling type Crest factor Input impedance Frequency Overload See table Measurement accuracy, temperature drifts and max min indications Current, voltage, temperature, resistance and frequency. For the current and voltage measurements: TRMS measurement of distorted sine waves. Direct 3; A Pmax=.7In; V Pmax=.7Un See table input impedances and overloads 40 to 440 Hz See table input impedances and overloads Compensation Only temperature measurement module. RTD For Pt , 3wire connection: up to 0Ω For resistance measur. with 20Ω range: up to max 0.Ω For resistance measurements with 200Ωrange: up to max 0Ω TC Internal cold junction, within temperature range from 0 to 50 C. Automatic or manual compensation from 0 to 50 C. Measurement accuracy, temp. drifts, max and min indications All accuracies and min/max indications are referred to an ambient temp. range of 25 C ±5 C, rel. humidity 60% and scale ratio (electrical/displayed scale) equal to. The conversion into F is obtained acting on the electrical/displayed scale ratio. Module Inputs Type Accuracy Temp. drift Min. indication ( ) Max. indicat. ( ) BQ LSX/ BQ LSE/ BQ LSF 200µA to 200µA 2mA to 2mA 20mA to 20mA 200mV to 200mV 2V to 2V 20V to 20V DC: ±(0.%RDG3DGT) 0% to 25% FS; ±(0.%RDG2DGT) 25% to 0% FS. TRMS (da 45 a 65Hz)*: ±(0.3%RDG3DGT) 0% to 25% FS; ±(0.3%RDG2DGT) 25% to 0% FS. ±50 ppm/ C * <45Hz >65Hz= ±(0.5%RDG3DGT) 0% to 25% FS; ±(0.5%RDG2DGT) 25% to 0% FS. ( ) The min. indication for TRMS measurement (AC or DC) is 0; it is possible to modify the decimal point position. 2 Specifications are subject to change without notice USC DIN DS ENG

3 Measurement accuracy, temp. drifts, max and min indications (cont.) All accuracies and min/max indications are referred to an ambient temp. range of 25 C ±5 C, rel. humidity 60% and scale ratio (electrical/displayed scale) equal to. The conversion into F is obtained acting on the electrical/displayed scale ratio. Module Inputs Type Accuracy Temp. drift Min. indication ( ) Max. indicat. ( ) BQ HSX BQ TRX Thermocouple 200mA to 200mA 2A to 2A 5A to 5A 20V to 20V 200V to 200V 500V to 500V 50 C to 760 C 58 F to 400 F 200 C to 260 C 328 F to 2300 F 200 C to 000 C 328 F to 832 F 50 C to 750 C 58 F to 382 F 200 C to 400 C 328 F to 752 F J J K K E E S S T T DC: ±(0.%RDG3DGT) 0% to 25% FS; ±(0.%RDG2DGT) 25% to 0% FS. TRMS (45 to 65Hz)*: ±(0.3%RDG3DGT) 0% to 25% FS; ±(0.3%RDG2DGT) 25% to 0% FS. ±(0.2%RDGDGT) ±(0.2%RDG2DGT) ±(0.2%RDG2DGT) ±(0.2%RDG4DGT) ±(0.2%RDG2DGT) ±(0.2%RDG4DGT) ±(0.2%RDG2DGT) ±(0.2%RDG4DGT) ±(0.2%RDG2DGT) ±(0.2%RDG4DGT) ±50 ppm/ C ±50 ppm/ C C 58 F 200 C 328 F 200 C 328 F 50 C 58 F 200 C 328 F C 400 F 260 C 2300 F 000 C 832 F 750 C 382 F 400 C 752 F * <45Hz >65Hz= ±(0.5%RDG3DGT) 0% to 25% FS; ±(0.5%RDG2DGT) 25% to 0% FS. ( ) The min. indication for TRMS measurement (AC or DC) is 0; it is possible to modify the decimal point position. Module Inputs Type Accuracy Temp. drift Min. indication Max. indicat. BQ TRX Thermoresistance 200 C to 850 C 328 F to 562 F C to C 328 F to392 F C to C 328 F to 392 F C to C 328 F to 392 F C to C 328 F to 392 F 60 C to 80 C 76 F to 356 F Pt00 Pt00 Pt00 Pt00 Pt250 Pt250 Pt500 Pt500 Pt000 Pt000 Ni00 Ni00 ±(0.2%RDG 2DGT) ±(0.2%RDG 4DGT) ±(0.5%RDG 5DGT) ±(0.5%RDG 5DGT) ±(0.5%RDG 5DGT) ±(0.5%RDG 5DGT) ±(0.5%RDG 5DGT) ±(0.5%RDG 5DGT) ±(0.5%RDG 5DGT) ±(0.5%RDG 5DGT) ±(0.5%RDG DGT) ±(0.5%RDG 2DGT) ±50 ppm/ C BQ TRX Resistance 0 to 20Ω 0 to 200Ω 0 to 2000Ω 0 to 20.00kΩ ±(0.2%RDG2DGT) 25% to 0% FS ±(0.2%RDG3DGT) 0% to 25% FS ±50 ppm/ C ( ) ( ) 2000 ( ) ( ) BQ TF NPN (DC) PNP (DC) NAMUR (DC) TTL (DC) Free of voltage contact (DC) 0.00% RDG ±3 digit ± 50 ppm/ C (*) (*) (*) 0000 (*) BQ TF2 Pickup (AC) Voltage (AC) up to 00VAC Voltage (AC) up to 500VAC 0.00% RDG ±3 digit ± 50 ppm/ C (*) (*) (*) 0000 (*) ( ) It is possible to modify the decimal point position. (*) The min indication is ,..., in case of rotation speed detection function Specifications are subject to change without notice USC DIN DS ENG

4 Input impedances and overloads Module Inputs Type Impedance Overload (continuous) Overloads (s) BQ LSX/ BQ LSE/ BQ LSF BQ HSX BQ TRX Thermocouple BQ TRX Thermoresistance BQ TRX Resistance BQ TF 200µA to 200µA 2mA to 2mA 20mA to 20mA 200mV to 200mV 2V to 2V 20V to 20V 200mA to 200mA 2A to 2A 5A to 5A 20V to 20V 200V to 200V 500V to 500V 50 C to 760 C 58 F to 400 F 200 C to 260 C 328 F to 2300 F 200 C to 000 C 328 F to 832 F 50 C to 750 C 58 F to 382 F 200 C to 400 C 328 F to 752 F 200 C to 850 C 328 F to 562 F C to 200,0 C 328 F to 392 F C to 200,0 C 328 F to 392 F 60 C to 80 C 76 F to 356 F 0 to 20Ω 0 to 200Ω 0 to 2000Ω 0 to 20.00kΩ NPN (DC) PNP (DC) NAMUR (DC) TTL (DC) Free of voltage contact (DC) J J K K E E S S T T Pt00 Pt00 Pt250/Pt00 Pt250/Pt00 Pt000/Pt500 Pt000/Pt500 Ni00 Ni00 2,2kΩ 22Ω 22Ω 2,2kΩ 200kΩ 200kΩ Ω 0.02Ω 0.02Ω 2MΩ 2MΩ 2MΩ 5mA 50mA 50mA 0V 50V 50V 0.8A 7.5A 7.5A 750V 750V 750V 0mA 50mA 50mA 20V 00V 00V A 00A 00A 000V 000V 000V I LK <0.5µA Max 5V Max 0V 90µA (*) 90µA (*) 90µA (*) 90µA (*) 600 Ω 600 Ω 600 Ω 600 Ω Max 5V Max 5V 5 VAC/DC 5 VAC/DC 5 VAC/DC 5 VAC/DC 5 VAC/DC Max 0V Max 0V 20 VAC/DC 20 VAC/DC 20 VAC/DC 20 VAC/DC 20 VAC/DC BQ TF2 Pickup (AC) Voltage (AC) up to 00VAC Voltage (AC) up to 500VAC 220 kω 950 kω 20 VAC/DC 600 VAC/DC 200 VAC/DC 600 VAC/DC (*) Maximum measuring current generated for resistance equal to 0 4 Specifications are subject to change without notice USC DIN DS ENG

5 Output specifications RS422/RS485 Serial output LED Connections Distance Terminalization Addresses Protocol Data (bidirectional) Dynamic (reading only) (on request) Module: BR SX Bidirectional (static and dynamic variables). Display of data reception/transmission Multidrop, 2 or 4 wires, 000 m Directly on the module by means of jumper to 255, selectable by means of keypad MODBUS RTU/JBUS Measurement, min value max value alarm status Static (reading/writing) All programming parameters, min max reset reset of latch alarm Data format 8 data bit, no parity, stop bit Baud rate selectable 4800, 9600,9200 Insulation and bit/s By means of optocouplers 4000 Vrms output to measuring inputs 4000 Vrms output to power supply input RS232 (on request) Module: BR SY Serial output Bidirectional (static and dynamic variables) Connections 3 wires, Distance max. 5m Data format start bit, 8 data bit, no parity, stop bit Baud rate Selectable 4800, 9600, 9200 and bit/s Other features Same as RS422/485 Alarm outputs (on request) Alarm type Overrange alarm, up alarm, down alarm, down alarm with startup deactivation up alarm with latch, down alarm with latch Alarm setpoint Adjustable from 0 to 00% of displayed electric range Hysteresis 0 to 00% of displayed range Ontime delay 0 to 255 s Offtime delay 0 to 255 s Output status Selectable: normally energized /deenergized Min response time 500 ms, with filter excluded, without alarm activation delay Output channels with module BO R (relay output). 2, independent with module 2 open collector outputs). BO R5 (4 relay outputs) Relay output BO R, R2, R4 Type SPDT AC : 8A, 250VAC DC 2: 5A, 24VDC AC 5: 2.5A, 250VAC DC 3: 2.5A, 24VDC Relay output BO R5 Type SPST (NO) AC : 5A, 250VAC DC 2: 3A, 24VDC AC 5:,5A, 250VAC DC 3:,5A, 24VDC Insulation 4000 V RMS output to measuring input, 4000 V RMS output to power supply input. Open collector output NPN transistor type V ON.2 VDC/ max. 00 ma V OFF 30 VDC max. Insulation By means of optocouplers 4000 V RMS output to measuring input 4000 V RMS output to power supply input Analogue output (on request) Module: BO AV Range 0 to 20 madc, 0 to 0 VDC Scaling factor Programmable within the entire retransmission range; allows to manage the retransmission of all the values from 0 to 20 ma / 0 to 0V Accuracy ± 0.2% FS (@ 25 C ± 5 C) Response time 0 ms Termperature drift ± 200 ppm/ C Load: 20 ma output 700 Ω 0 V output 0 kω Insulation By means of optocouplers 4000Vrms output to measuring input 4000Vrms output to power supply input Notes: The two outputs cannot be used at the same time. Excitation output (on request) BQ LSE Module Voltage 3 VDC ±0%, max. 50 ma BQ LSF Module Voltage 25 VDC ±0%, max. 25 ma BQTF Module Voltage 8.2VDC ±0%, max 0mA. Voltage 2 3VDC ±0%, max 40mA. Insulation 25VRMS output to measuring input 4000 VRMS output to power supply input BO R2 (2 relay outputs). 4, independent with module BO R4 (2 relay outputs Specifications are subject to change without notice USC DIN DS ENG

6 Software functions Min / Max storage Password st level 2nd level Measurement selection Function (only BQTFx) Integration time selection Scaling factors Operating mode Electrical range Decimal point position Automatic storage (in the EEPROM) of the minimum and maximum measured value from the previous memory reset Numeric code max 4 dgt 2 levels of data protection. 0 to 4999 completly protected to 9999 access to programming is protected. Alarm setpoints are directly programmable from the measuring mode. Depending on the module: measuring range and type of probe (resistance, RTD thermoresistance, TC thermocouple) or measuring type (TRMS or DC). Calculated functions of channel A and B: F: scaled value of channel A; F2: /A; F3: AB; F4: (AB)/B*00; F5: A/B; F6: B/(AB)00; F7: rotation sensing. Automatic or from 00.0 to ms only in the current and voltage measurement. (BQTFx excluded) Electrical scale compression, displayed scale compression/expansion (max. 2 without filter, up to 0 with filter) Programmable within the whole measuring range Programmable within the display range Displayed range of the variable Programmable within the display range Pulse per revolution BQTFx only: programmable from to 9999 Input engineering unit BQTFx only: programmable among Hz, khz, rpm, krpm, rph, krph Digital filter Filter operating range 0 to 9999 Filtering coefficient to 32 Scaling Selection of min value of the input range. Selection of max value of the input range. Selection of decimal point position. Selection of min display value. Selection of max display value. Linearization Points Up to 6 Input range Selectable by every single point Output range Selectable by every single point UscSoft Software for programming USC by means of PC (Windows 95, 98se, ME, XP) by means of serial port RS485 and relevant connection cable. The software is available in English, Spanish, Italian, German, French. See also Programming of USC by means of PC. Supply Specifications AC/DC voltage DC voltage only 90 to 260V (standard) 8 to 60V (on request) 0 to 28V (on request) Energy consumption 30VA/2W (90 to 260V) 20VA/2W (8 to 60V) 7.5W (0 to 28V) 6 Specifications are subject to change without notice USC DIN DS ENG

7 General Specifications Operating temperature Storage temperature Insulation reference voltage Insulation Dielectric strength Rejection NMRR CMRR EMC 0 to 50 C (32 to 22 F) (H.R. < 90% noncondensing) 0 to 60 C (4 to 40 F) (H.R. < 90% noncondensing) 300 V RMS to ground (500V input) See table Insulation between inputs and outputs 4000 V RMS for minute 40 db, 40 to 60 Hz 00 db, 40 to 60 Hz EN600062, IEC EN600063, IEC Safety Standards Safety EN 600, IEC 600 Connections Screw type Cable crosssection area Max. 2.5 mm 2 ; Min./Max. screws tightening torque: 0.4 Nm / 0.6 Nm Housing Dimensions 44 x 3 x 07 mm Material PCABS, selfextinguishing: UL 94 V0 Protection degree IP20 Weight 560 g approx (included all modules and packing) Approvals CE, UR, CSA Excitation output Insulation between inputs and outputs BQ LSF BQ LSE BQ TF BQ TF (8.2V) Max 30s TF (8.2V) Continuous TF (8.2V) Continuous LSF/LSE Continuous TF Max 30s TF Max 30s LSF/LSE TF Not allowed Meas. inputs Relay Output Static Output Analogue Output Serial Port AUX p.supply 90260VAC/ DC p..supply 860VAC/ DC p. supply Meas. inputs Relay output Static output Analogue output Serial Port AUX p.supply 90260VAC/ DC p. supply 860VAC/ DC p.supply 4kV 4kV 4kV 4kV 25V 4kV 4kV 4kV 2kV 4kV 4kV 4kV 4kV 4kV 4kV 2kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 25V 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV 4kV USC architecture Remote programming by means of PC Measuring inputs: : mamvv : AV C/ F: TCPtNi Frequency Digital input: Alarm reset Auxiliary power supply: 3V / 50mA DC 25V / 25mA CC AUXILIARY DIGITAL INPUTS (FUTURE FUNCTION) ALARM OUTPUTS COMMUNICATION POWER SUPPLY INTERNAL BUS MEASURING INPUTS DIGITAL INPUTS AUXILIARY POWER SUPPLY alarm 2 alarms 4 alarms Analogue outputs: x 20mA/0V DC Serial ports: RS485 RS to 260V AC/DC 8 to 60V AC/DC Specifications are subject to change without notice USC DIN DS ENG

8 Available modules Possible module combinations Type UDSDIN main unit input: 200µA, 2mA, 20mA, 200mA, 2V, 20V input: 200µA, 2mA, 20mA, 200mA, 2V, 20V excitation output input: 200mA, 2A, 5A, 20V, 200V, 500V N. of ch. Ordering code BD XX BQ LSX BQ LSE/ BQ LSF BQ HSX Input: 20Ω, 200Ω, 2kΩ, 20kΩ BQ TRX TC: JKSTE, Pt Pulse signals input: 0.00Hz to 50kHz for DC signals Pulse signals input: 0.00Hz to 50kHz for AC signals Analogue output 0 to 20mA, 0 to 0VDC BQ TRX 2 BQ TF 2 BQ TF2 BO AV Relay output BO R Slot Basic Unit A B C D E Measuring inputs: LSX, LSE, LSF, HSX, TRX, TF, TF2 RS485 serial port: SX RS232 serial port: SY Analogue output: AV (*) Relay outputs and/or open collector: R, R2, R4, R5 Power supply: H, L, 3 (*) Up to module max. Relay output 2 BO R2 Outputs: 2 relays 2 open collectors 4 BO R4 Relay output 4 BO R5 RS485 Serial Port BR SX RS232 Serial Port BR SY Power supply 8 to 60V AC/DC Power supply 90 to 260V AC/DC BP L BP H Power supply 0 to 28V DC BP 3 Used calculation formulas Only for TRMS Measurements Instantaneous effective voltage (TRMS) n V ( V ) n 2 i Instantaneous effective current (TRMS) n A ( A ) n 2 i 8 Specifications are subject to change without notice USC DIN DS ENG

9 Wiring diagrams Process signal wiring diagrams BQ LSX/LSE/LSF Fig. BQ LSX/LSE/LSF Fig. 2 BQ LSE/LSF Fig. 3 Current measurements Voltage measurements Probe Voltage measurements 4wire connection to probe Vdc Probe Signal output Probe power supply BQ LSE/LSF Fig. 4 BQ LSE/LSF Fig. 5 BQ LSE/LSF Fig. 6 Probe Voltage measurements 3wire connection to probe Vdc Probe power supply Probe Signal output Probe Current measurements 4wire connection to probe Vdc Probe power supply Probe Signal output Probe Current measurements 3wire connection to probe Vdc Probe power supply Probe Signal output Wirings for highlevel signals BQ LSE/LSF Fig. 7 BQ HSX Fig. 8 BQ HSX Fig. 9 Probe Current measurements 2wire connection to probe Vdc Probe power supply Probe Signal output Current measurements Voltage measurements Specifications are subject to change without notice USC DIN DS ENG

10 Wiring diagrams (cont.) Wiring diagrams for temperature measurements BQ TRX Fig. 0 BQ TRX Fig. BQ TRX Fig. 2 Temp. measur. from thermocouple Temp. measur. from thermoresistance Resistance measurements Wiring diagrams for frequency measurements BQ TF Fig. 3 BQ TF Fig. 4 BQ TF Fig.5 ENCODER NPN/PNP NAMUR NPN and contact BQ TF Fig. 6 BQ TF Fig. 7 BQ TF Fig. 8 PNP and contact NPN/PNP TTL 0 Specifications are subject to change without notice USC DIN DS ENG

11 Wiring diagrams (cont.) BQ TF Fig. 9 BQ TF2 Fig. 20 BQ TF2 Fig. 2 Auxiliary command Pickup max 00VAC Max 500VAC Wiring diagrams for power supply BQ TF2 Fig. 22 BP H: power supply BP L: power supply BP 3: power supply Auxiliary command F= 630mA T 250V 5x20mm F= 3.5A T 250V 5x20mm F= 3.5A T 250V 5x20mm Wiring diagrams of optional modules BO AV: analogue output (0V, 20mA DC) BO R: relay output BO R2: 2 relay outputs BO R5: 4 relay outputs Specifications are subject to change without notice USC DIN DS ENG

12 Wiring diagrams of optional modules (cont.) SY LED RX TX BO SY: RS232 direct connection to PC by means of COM port. RS232 has no terminalization. Vcc GND RX TX BO R4: dual relay output dual open collector output: the load resistances (Rc) must be designed so that the close contact current is lower than 00mA; the VDC voltage must be lower than or equal to 30VDC. VDC: power supply output Vo: positive output (open collector transistor). GND: ground (open collector transistor). RS,2,3...N NON terminalized network Terminalized network BR SX: RS485 4wire connection: additional devices provided with RS485 port (indicated as RS,2,3...N) are connected in parallel. The termination of the serial port is carried out only on the last instrument of the network. The serial module is provided with a jumper for the termination of the RS485 network as shown in the figure above. Note: particular types of cables or plants may require an external termination. For the network connections use twisted cable type AWG26. Programming USC by means of PC To USC m 2 USC is programmable by PC by means of the UscSoft software (available on request). The user can program all parameters of USC that will be subsequently uploaded and set in the instrument by the RS485 network (BR SX). Should USC be without the RS485 serial module, all programming parameters will be uploaded and set in the instrument by the RS232 auxiliary serial connection () located on the side of the measuring input module using the special connection cable (2) available on request, as shown in the figures on the left. It is also possible to program the instrument using the connector () by means of the HyperTerminal Windows functions of a PC. Note: the RS232 auxiliary port IS NOT insulated from the measuring inputs. To PC 2 Specifications are subject to change without notice USC DIN DS ENG

13 Dimensions 44 mm 3 mm 44 mm 07 mm Dimensions of optional module in scale : Specifications are subject to change without notice USC DIN DS ENG

14 Modules Input modules Output modules BQ LSX, BQ LSE, BQ LSF, BQ HSX, BQ TRX, BQ TF, BQ TF2 Measuring inputs BO AV Single analogue output 0V, 20mA Output modules BO R Single relay output BO R2 Dual relay output BO R4 Dual relay output Dual open collector BO R5 4relay output Serial port modules Power supply modules BR SX RS485 Serial port BR SY RS232 Serial port BP H Power supply: 60 to 260V AC/DC BP L Power supply: 8 to 60V AC/DC BP 3 Power supply: 0 to 28V DC 4 Specifications are subject to change without notice USC DIN DS ENG

Digital Panel Meters Modular signal s conditioner Type USC-DIN

Digital Panel Meters Modular signal s conditioner Type USC-DIN Digital Panel Meters Modular signal s conditioner Type DIN Linearization of V and A inputs up to 6 points Multiinput modular signal s conditioner 0.% RDG basic accuracy TRMS AC current and voltage measurements

More information

Digital Panel Meters Modular Indicator and Controller Type UDM40

Digital Panel Meters Modular Indicator and Controller Type UDM40 ISE, Inc. 000 Royalton Rd., Cleveland, OH 4433 Tel: (440) 2373200 Fax: (440) 237744 http://iseinc.com Digital Panel Meters Modular Indicator and Controller Type The alarm status can be coupled to the different

More information

Digital Panel Meters Modular Indicator and Controller Type UDM35

Digital Panel Meters Modular Indicator and Controller Type UDM35 ISE, Inc 000 Royalton Rd. Cleveland, OH 4433 Tel: (440) 2373200 Fax: (440) 237744 http://iseinc.com Digital Panel Meters Modular Indicator and Controller Type UDM35 Front protection degree: IP67, NEMA4x

More information

Energy Management Modular Energy meters Type EM2-96

Energy Management Modular Energy meters Type EM2-96 Energy Management Modular Energy meters Type EM2-96 Product Description µp-based modular energy meter with a built-in configuration key-pad. The energies are both partial and total counted. The housing

More information

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Modular solution based on the combination of two units: VMU-E analysis unit and VMU-X universal power supply and RS485 communication unit.

More information

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96 Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96 Class 1 (active energy) Class 2 (reactive energy) Accuracy 0.5% RDG (current/voltage) Universal utility meter and power

More information

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X Modular solution based on the combination of two units: VIM-E analysis unit and VIM-X universal power supply and RS485 communication unit.

More information

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model). SCEE AR 3 - Smart Analyzer 485/Ethernet with web visualization Three-phase electricity meter with instantaneous reading of electrical variables. System variables: V, A, kw, kva, kvar, PF and Hz. Variables

More information

Modular Panel Meter Series EDM 35

Modular Panel Meter Series EDM 35 Modular Panel Meter Series EDM 35 CONTENTS Page 1. Introduction 2 1.1 Getting Started 2 1.2 Overall Description 3 1.3 Features 3 1.4 Block Schematic 4 2. Unit Description 4 2.1 Modules 4 2.2 Main Unit

More information

Process displays For current and voltage

Process displays For current and voltage Features Voltage input TRMS-AC/DC up to 600 V Current input AC/DC 1 A, 5 A and shunt (precision resistor) 60 or 100 mv With 2 or 4 limits Display range can be linearised Min, Max, Hold functions 4 20 ma

More information

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS I-7520 RS-232 to RS-485 Converter I-7510 RS-485 Repeater RS-232 RS-485 I-7000 SERIES Common Specifications Isolation voltage: 3000VDC Speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115000 Dual watchdog

More information

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS ELK. ETK COMPACT BASIC CONTROL - SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS TIMER - SOFT START OUTPUT

More information

Energy Management Energy Transducer Type ET112

Energy Management Energy Transducer Type ET112 Energy Management Energy Transducer Type Single phase energy transducer Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Accuracy ±0.5% RDG (current/voltage Direct current measurement

More information

WM20. Power analyzer for three-phase systems. Benefits. Description

WM20. Power analyzer for three-phase systems. Benefits. Description WM20 Power analyzer for three-phase systems Description WM20 is a modular power analyzer for single-, two- and three-phase systems. It is made up of a maximum of three components: the main unit that displays

More information

Energy Management BUS Adapter Type VMU-B 01

Energy Management BUS Adapter Type VMU-B 01 Energy Management BUS Adapter Type VMU-B 01 RS485 (Modbus) to M-Bus communication adapter EM21-72D, EM24-DIN and EM33-DIN self recognition Front diagnostic LED s Universal 18 to 260 VAC/DC power supply

More information

DINALOG A 144 x 36 A1400 Light-Strip Indicator

DINALOG A 144 x 36 A1400 Light-Strip Indicator DINALOG A x 6 A00 Light-Strip Indicator -9-0-0 /.00 Front panel dimensions: x 6 mm Light-strip indicator with 7 high-contrast LEDs Red LED display color Digital display range for portrait format: 999 to

More information

Energy Management BUS Adapter Type VMU-B

Energy Management BUS Adapter Type VMU-B Energy Management BUS Adapter Type RS485 (Modbus) to M-Bus communication adapter EM24-DIN and EM21-72D self recognition Front diagnostic LED s Universal 18 to 260 VAC/DC power supply Dimensions: 1-DIN

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type

More information

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES D1000 FEATURES Complete sensor to RS-232/RS-485 interface. 500V rms analog input isolation. 15 bit measurement resolution. Continuous self-calibration;

More information

Amplifiers, Counters, Timers & Controls

Amplifiers, Counters, Timers & Controls Amplifiers, Counters, Timers & Controls Panel Meter 814 Counter/Timer/Rate Indicator 815-817 Speed Monitor 818-819 Signal Converter 820-822 Power Supplies/Amplifier 823-824 813 Panel Meter Panel Meter

More information

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels Description Features Frequencies from 0.005 Hz to 1 MHz 6-digit resolution at update rates up to 25/s Selectable

More information

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description Description LAUREL ELECTRONICS, INC. Features Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 Arithmetic functions A+B, A-B, AxB, A/B, A/B-1 applied to rate or total for channels

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals

More information

EM271. Multi-channel power analyzer. Benefits. Description

EM271. Multi-channel power analyzer. Benefits. Description Multi-channel power analyzer Description Multi-load power analyzer for single or three-phase systems installable on panels or DIN rails. Manages current input via two groups of split-core current sensors

More information

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features. Description LAUREL ELECTRONICS, INC. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets Features Frequencies up to 1 MHz Totals stored in non-volatile

More information

Multifunction Transducer MT440

Multifunction Transducer MT440 Multifunction Transducer MT440 Voltage and current auto range measurements up to 600V, 12.5A Universal wide auxiliary power supply range 24 300 Vdc, 40 276 Vac Power accuracy class 0.5 (EN 60 688), Up

More information

EM270. Multi-channel power analyzer. Benefits. Description

EM270. Multi-channel power analyzer. Benefits. Description Multi-channel power analyzer Description Multi-circuit power analyzer for single or threephase systems installable on panels or DIN rails. Manages current input via two current transformer blocks connected

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450 Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450 o Measuring of resistance of RTD sensors (Pt100, Pt1000, Ni100, Cu10,...) o Accuracy class up to: 0.5 o Programmable input

More information

RS-485 I/O Modules: ADAM-4000

RS-485 I/O Modules: ADAM-4000 RS-485 I/O Modules: ADAM-4000 23 ADAM-4000 Series Overview ADAM-4000 Series Remote Data Acquisition and Control Modules Overview 23-2 and Controller Module Selection Guide 23-4 I/O Module Selection Guide

More information

Trident and Trident X2 Digital Process and Temperature Panel Meter

Trident and Trident X2 Digital Process and Temperature Panel Meter Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products

More information

SX90 Process Controller

SX90 Process Controller Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

User friendly and easy to program

User friendly and easy to program New Product Digital Panel Meter WPMZ User friendly and easy to program μm m/min mm rpm m/min ton Universal design! New Digital Panel Meter Specification is subject to change without notice Watanabe Electric

More information

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation

More information

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC. Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals

More information

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points) Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE

More information

LBVR1718. Description. Features channel paperless recorder

LBVR1718. Description. Features channel paperless recorder LBVR1718 18 - channel paperless recorder Description It is the world first paperless recorder of the same size in highest resolution 640x480 pixels VGA TFT display, infrared detector, maximum 18 channels,

More information

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET & DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

User s manual. Programmable panel meter IPD

User s manual. Programmable panel meter IPD User s manual Programmable panel meter IPD Assembly Wall assembly: +0,5 +0,2 Window of 46 x 91 mm (2.5" x 3.5" ) Made with ABS (UL94-HB) -0-0 General cares in the installation The equipments must not be

More information

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S Multi-instrument 4921210107G Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Intelligent Suitable for all 3-phase network topologies Replaces transducers Accuracy U,

More information

Programmable Relay ZEN V2 Units

Programmable Relay ZEN V2 Units Programmable Relay ZEN V2 Units Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty

More information

-10 to 10V to User range setting. 4 to 20mA 0 to to 20mA 500.0nA

-10 to 10V to User range setting. 4 to 20mA 0 to to 20mA 500.0nA Analog I/O Analog Input Modules R60AD4 R60ADV8 Number of Analog Input Points 4 points (4 channels) 8 points (8 channels) Analog Input 10 to 10 VDC (input resistance 1MΩ) Analog Input DC (input resistance

More information

MIC-2 Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules

More information

C160 Wall-/Pipe Mounted Universal Process Indicator

C160 Wall-/Pipe Mounted Universal Process Indicator Data sheet DS/ EN Rev. I Wall-/Pipe Mounted Universal Process Indicator reliable process indicator, wherever it s needed High visibility LED display the clearest view of your process status 0.1% measurement

More information

PD765 TRIDENT. Trident Series Process & Temperature Meters.

PD765 TRIDENT. Trident Series Process & Temperature Meters. PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) Type 4X, NEMA 4X, IP65 Front 1/8 DIN Shallow

More information

Digital Indicator Solutions

Digital Indicator Solutions Digital Indicator Solutions Loop-Powered Attachable Compact Attachable Loop-Powered Smart Compact System Loop-Powered Compact Smart System Intelligent Smart System "Intelligent" Options Dual & Display

More information

/8 DIN Universal Process Indicator

/8 DIN Universal Process Indicator Data Sheet SS/_ High visibility LED display the clearest view of your process status.% measurement accuracy precise indication of process measurement Analog and relay outputs as standard alarm and retransmission

More information

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance red display of -9999 99999 digits installation depth: 120 mm without

More information

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES Digital Panel Indicators A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input Analogue Output

More information

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities COMMANDER Universal Process Controller Specification DataFile PID controller with one shot autotune single loop, heat/cool and ramp/soak as standard Quick code, front face or PC configuration easy commissioning

More information

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement Acquisition Measurement Control The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input

More information

Safety: UL508 EMC: CE IEC , IEC Vibration: IEC (2 g s during operation) Warranty

Safety: UL508 EMC: CE IEC , IEC Vibration: IEC (2 g s during operation) Warranty NA-4020/4021 RS-485 or RS-232 network adaptors ioogik 4000 Modbus RS-485 NA-4020 SYS TxD RxD I/O Field Power CH0 24V 0V SG SG System Power (0 VDC) System Power (24 VDC) Shielding Ground Non-isolation Switching

More information

Displays Transducers. Displays and transducers

Displays Transducers. Displays and transducers JJ Displays JJ Transducers Displays and transducers DS_Displays_and_transducers 06/2016 225 Displays and transducers Our electronic devices for flow and volume measurement are suitable for all SIKA flow

More information

PD765 TRIDENT. Trident Series Process & Temperature Meters.

PD765 TRIDENT. Trident Series Process & Temperature Meters. PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56" (14.2 mm) or 1.20" (30.5 mm) Linear or Square Root with Low-Flow Cutoff

More information

MPV. Process Panel Display. Dual-Line Rate and Total

MPV. Process Panel Display. Dual-Line Rate and Total Process Panel Display Dual-Line Rate and Total measuring monitoring analyzing MPV Pulse or Analog s Displays Rate and Total Simultaneously Square Root Extraction 5, 10, or 24 V DC Flowmeter Power Supply

More information

DS 96/48 PK. Digital indicator. Manual 42/33-90 EN Rev. 00 DIM

DS 96/48 PK. Digital indicator. Manual 42/33-90 EN Rev. 00 DIM DS 96/48 PK Digital indicator Manual 42/33-90 EN Rev. 00 A1 A2 DIM E DS 96/48 PK Digital Indicator Manual Document No. 42/33-90 EN Edition 06.01 Revision 00 Manufacturer: ABB Automation Products GmbH Höseler

More information

Signal Conditioning Modules and Terminal Boards

Signal Conditioning Modules and Terminal Boards Signal Conditioning Modules and Terminal Boards Terminal Board Selection Guide 17-2 Isolated Signal Conditioning Modules ADAM-3000 Series Isolated Signal Conditioning Modules 17-4 ADAM-3011 ADAM-3013 ADAM-3014

More information

PXR Series Advanced Self-Tuning Temperature and Process Controllers

PXR Series Advanced Self-Tuning Temperature and Process Controllers PXR Series Advanced Self-Tuning Temperature and Process Controllers Key Features PID Description with fuzzy control of self-tuning 16 Ramp/soak segments Large LED display Auto-tune Timer function Heater

More information

DIGITAL INDICATING CONTROLLER

DIGITAL INDICATING CONTROLLER DB1000 SERIES DIGITAL INDICATING CONTROLLER The DB1000 series is a 96 96mm digital indicating controller with the indicating accuracy of ±0.1% and the control cycle of approximately 0.1 seconds. Various

More information

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. IQ240 Panel Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high

More information

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter S-14 Compact Digital Multimeter S-14 Compact Digital Multimeter SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter

More information

iologik 4000 Series (M) Modules

iologik 4000 Series (M) Modules iologik 4000 Series (M) s Remote I/O modules Features and Benefits I/O expansion without a backplane Active communication with MX-AOPC UA Server Supports SNMP v1/v2c Easy configuration with Modular ioadmin

More information

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 12/99 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC 1000 and UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

Panel Meter Economical Panel Meter for Process, Temperature and Electrical Measurement

Panel Meter Economical Panel Meter for Process, Temperature and Electrical Measurement 8 DN Multisignal Panel Meter Economical Panel Meter for Process, Temperature and Electrical Measurement DP20 TM DP20 meter shown smaller than actual size. OME s new multisignal panel meter delivers high-performance

More information

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS... 2 content DISPLAYS... 4 smart meters... 6 panel meters... 7 field displays... 8 display types... 10 loop powered displays... 12 TRANSMITTERS & CONVERTERS... transmitters... 15 converters... 18 serial data

More information

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET Measurement input, auto range Up to 1000 V AC L-L Up to 12.5 A (sinusoidal) 16 400 Hz Output Up to four analogue outputs Relay output RS 485 Modbus

More information

Tachometers TC-4B-V TC-6A-V Electronic cam-operated switching devices FC-21-V... 50

Tachometers TC-4B-V TC-6A-V Electronic cam-operated switching devices FC-21-V... 50 List of content page Counters and indicators DA5-IU-C... 10 DA5-IU-2K-C... 12 DA5-IU-2K-V... 12 KCM-51-C... 14 KCM-51-V... 14 KCM-70-C... 16 KCM-70-V... 16 KCM-70A-C... 18 KCM-70A-V... 18 KCT-6S-C... 20

More information

Temperature/Process Controllers Manual

Temperature/Process Controllers Manual 3200 SERIES Temperature/Process Controllers Manual The innovative range of 3200 controllers offer precision control of temperature and other process variables together with a host of advanced features

More information

Multichannel power analyzer for single, two and three-phase systems

Multichannel power analyzer for single, two and three-phase systems WM50 Multichannel power analyzer for single, two and three-phase systems Description WM50 is a multichannel power analyzer for single, two and three-phase systems. Using TCD12 split core current sensors,

More information

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0. LAUREL ELECTRONICS, INC. Laureate Thermocouple Panel Meter / Controller Features Factory calibrated for thermocouple types J, K, T, E, N, R, S Entire range of each thermocouple in one scale Highly accurate

More information

Wall-/Pipe Mounted Universal Process Indicator

Wall-/Pipe Mounted Universal Process Indicator Data Sheet SS/_8 Wall-/Pipe Mounted Universal Process Indicator High visibility LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement

More information

VMU-C EM system. Integrated modular system to monitor conventional energy. Benefits. Description

VMU-C EM system. Integrated modular system to monitor conventional energy. Benefits. Description VMU-C EM system Integrated modular system to monitor conventional energy Description VMU-C EM is a modular system that records, monitors and transmits analog and digital signals from an industrial, commercial

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

ProVU 4 Advanced Temperature & Process Controller

ProVU 4 Advanced Temperature & Process Controller ProVU 4 Advanced Temperature & Process Controller 1/4 DIN Format Graphical / text LCD Display (red/green) Profiling option Datalogging option (data, alarms & events) 5 language (English, French, German,

More information

Voltage Transducer UMT516 / MT516

Voltage Transducer UMT516 / MT516 Voltage Transducer UMT516 / MT516 True RMS AC voltage measurements Voltage auto range measurements up to 600V # Wide frequency measurement range 16 400 Hz High accuracy class 0.2 (IEC-688), 0.1 on communication

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater

More information

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. IQ300 Wall Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high

More information

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend Solid State Relays with Failure Detection Function G3PC Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). Detects failures

More information

Setpoint adjuster SG 9648 Output standard signals 0/ ma or 0/ V DC

Setpoint adjuster SG 9648 Output standard signals 0/ ma or 0/ V DC adjuster SG 9648 Output standard signals 0/4... 20 ma or 0/2... 10 V DC Features M LEDDisplay 14.2 mm red M Display range ± 9999(0) digit M Indicating range and decimal point free programmable M Set point

More information

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere!   Toll Free Digital Indicating Controllers JC Series High performance controllers...at the lowest prices anywhere! www.mod-tronic.com Toll Free 1-800 794-5883 Standard Features Structure Units available in standard

More information

S1MMmA500VM S1MMmA500VLM S1MMmA500VHM. Technical data. 3-phase energy meter with universal current input

S1MMmA500VM S1MMmA500VLM S1MMmA500VHM. Technical data. 3-phase energy meter with universal current input 3-phase energy meter with universal current input Equivalent to class 0,5S (KWh) of E6053- Equivalent to class 0,5S (KVARh) of E6053-4 Accuracy ±0,5% RDG Universal input for current measurement Energy

More information

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS. The LPI-LCD-6-4~20mA panel display is ideal for displaying a variety of process variables, and is easy to scale to your required engineering units. LPI-LCD-6 4~20mA Panel Display. Loop powered. Loop powered

More information

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging

More information

CJ1W-PTS/PDC/PH41U/AD04U

CJ1W-PTS/PDC/PH41U/AD04U CJ-series Process Analog I/O Unit A Single Unit Handling All Types of Inputs such as Temperature Sensor Inputs and Analog Signal Inputs (e.g., 4 to 20 ma or 1 to 5 V) A Unit supports four input channels,

More information

02/11/2015

02/11/2015 DIN Rail Mount 35 mm HSV Part number 84874320 Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - 3-wire PNP or NPN, Namur, voltage 0-30V or volt-free contact

More information

Signal Doublers. VariTrans A 20300

Signal Doublers. VariTrans A 20300 ProLine Interface Technology Signal Doublers Signal doublers with two switchable calibrated outputs in a 6 mm housing, also for applications with high output loads. The Task Isolation and transmission

More information

Millenium II +: general characteristics

Millenium II +: general characteristics Millenium II +: general characteristics Starter kit Blind Temperature sensors Special starter kits Bare board Power supply Level detection Local extensions Accessories Standard Expandable Adjacent extensions

More information

UNIVERSAL CURRENT CONVERTER

UNIVERSAL CURRENT CONVERTER UNIVERSAL CURRENT / VOLTAGE CONVERTER AC/DC Current / Voltage Analyzer The is the first CURRENT / VOLTAGE CONVERTER & ANALYZER ALL IN ONE - of the market. It allow you to connect all isolated current sensors.

More information

Temperature Switches

Temperature Switches ETS 00 Series Temperature Switch for Inline and Tank Mounting Applications Description The ETS 00 is a compact electronic temperature switch with 4-digit digital display. Pressure resistant to 8700 psi,

More information

Zelio Count - Counters RC87610

Zelio Count - Counters RC87610 Zelio Count - Counters RC87610 Catalog March 05 Class 9051 CONTENTS Description..............................................Page Product Description........................................... RC87610050

More information

High Voltage DC Meter

High Voltage DC Meter High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions ICP DAS 2015 M2M WLAN Wireless Solutions Industrial Computer Industrial Product Data Computer Acquisition Product System Data Acquisition System PAC WLAN Wireless Solutions Wi-Fi Products WLAN Converter

More information

Controller. Application Example Climate chambers, dryer, heat threating plants, sterilisers, packing machines, food application, laboratory

Controller. Application Example Climate chambers, dryer, heat threating plants, sterilisers, packing machines, food application, laboratory Product Information Controller Application The NKS-4x is an universal temperature controller for all tasks, which can be solved with 2-point control, 3-point control, continous PID control or 3-point stepping

More information

Temperature/Process Meter

Temperature/Process Meter Temperature/Process Meter High-Performance Temperature Meter Accepts Temperature/Analog Inputs Multi-range capability: a single processor connects 14 types of sensors with varying current/voltage Programmable

More information

TECHNICAL DATA SHEET. ProVU 4 Advanced Temperature Controller. Features. Description

TECHNICAL DATA SHEET. ProVU 4 Advanced Temperature Controller. Features. Description ProVU 4 Advanced Temperature Controller ¼ DIN Format Graphical / text LCD Display (red/green) Profiling option Datalogging option (data, alarms & events) 5 language (English, French, German, Italian, Spanish)

More information

iothinx 4500 Series (45MR) Modules

iothinx 4500 Series (45MR) Modules iothinx 4500 Series (45MR) Modules Modules for iothinx 4500 Series Feature and Benefits Easy tool-free installation and removal Built-in LED indicators for IO channels Wide operating temperature range:

More information

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features: DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S:

More information