The operator has activated this LED to identify this chassis. This chassis is not being identified. Fabric modules are all operational.

Size: px
Start display at page:

Download "The operator has activated this LED to identify this chassis. This chassis is not being identified. Fabric modules are all operational."

Transcription

1 s Chassis s, page 1 System Controller s, page 2 Supervisor Module s, page 3 Fan Tray s, page 3 Fabric Module s, page 4 Line Card s, page 4 Power Supply s, page 5 Chassis s The chassis s are located at the top of the front of the chassis. They indicate whether each type of module (supervisors, controllers, line cards, fabric modules, fan trays, and power supplies) are fully functional or have a fault condition. The following table describes what each of these s can indicate. blue The operator has activated this to identify this chassis. This chassis is not being identified. Supervisor modules are all operational. Check the Supervisor Module s for more information. Fabric modules are all operational. Check the FAB description in the Fan Tray s for more information. Line cards (I/O modules) are all operational. Check the Line Card s, on page 4 for more information. SUP FAB IOM 1

2 System Controller s s PSU FAN PWR MGMT Power supplies are all operational. Check the Power Supply s for more information. Fan trays are all operational. Check the Fan Tray s for more information. Sufficient power is available for all of the installed modules. Either of the following: Insufficient power for at least one of the installed modules. The configured power redundancy mode differs from the operational power redundancy. System Controller s The system controller module s are located on the left side of the module. The following table describes the possible states for each of these s. STS ACT blue amber red The operator has activated this to identify this module in the chassis. This module is operational. This module is booting up. Temperature exceeds major alarm threshold. The module is not receiving power. The controller module is operational and in active mode. The controller module is operational and in standby mode. 2

3 s Supervisor Module s Supervisor Module s The Beacon (), (STS), and Active (ACT) s are located on the lower left front of the supervisor module. The management port link and active s are located immediately above the port on the front of the module. The following table describes the possible states for each of these s. STS ACT (management port LINK) (management port ACT) blue amber red green The operator has activated this to identify this module in the chassis. This module is operational. This module is booting up. Temperature exceeds major alarm threshold. The module is not receiving power. This module is operational and in active mode. This module is operational and in standby mode. The management port is linked up. The management port is not linked up. The module is transmitting or receiving. The module is not transmitting or receiving. Fan Tray s The fan tray s are located on the lower right portion of the module. The following table describes the possible states indicated by this module. Blue The operator has activated this to identify this module in the chassis. 3

4 Fabric Module s s FAN Red The fan tray is operational. One or more fans in this fan tray has failed. No power is going to the fan tray. Verify that the even numbered fabric slot (FM 2, FM 4, or FM 6) behind the fan tray has one of the following in order to power the fan tray: Functioning fabric module (N9K-C9508-FM, N9K-C9508-FM-E, or N9K-C9508-FM-E2) FAB The fabric modules behind this fan tray are operational. At least one fabric module behind this fan tray is not operating. No power is going to the fabric module behind this fan tray. Fabric Module s The fabric modules are located behind the fan trays. /top /bottom Blue red amber The operator has activated this beacon () to identify this module in the chassis. Note When the operator activates the /top, the on the covering fan module also activates (lights). The fabric module is operational. The fabric module has a fault. The fabric module is booting up. No power is going to the fabric module. Line Card s The Beacon () and (STS) s are located on the front left of the module, and the Link for each port is located between the two rows of ports (each of these s is a triangle pointing to the port above or below the ). 4

5 s Power Supply s STS blue red The operator has activated this to identify this module in the chassis. This is not being used. All diagnostics passed. This module is operational (normal initialization sequence). Indicates one of the following: The module has detected a slot ID parity error and will not power on or boot up. The module is not fully inserted, and it is not making a reliable connection with the supervisor. The module has failed diagnostic tests and has powered down. An overtemperature condition has occurred. A major temperature threshold has been exceeded during environmental monitoring. amber Indicates one of the following: The module is booting up or initializing. The module is resetting and both ejector levers are out. The module has been inserted during the initialization process. The module could not power up because of insufficient power. Link (for each port) Orange orange The module is not receiving power. The port is active (the link is connected and active). The port is disabled by the operator or is not initializing. The port is faulty and disabled. The port is not active or the link is not connected. Power Supply s The power supply s are located on the upper left front portion of the module. Combinations of states indicated by the OK and FAIL (or FAIL/ID) s indicate the status for the module as shown in the following table. 5

6 Power Supply s s OK green FAIL or FAIL/ID amber Power supply is on and outputting power to the switch. Power supply is connected to AC power source but not outputting power to the switch. The power supply might not be properly installed in the chassis. Either all of the installed power supplies are not receiving power or an uninstalled power supply is not receiving power. Power supply is operating but a warning condition has occurred possibly one of the following conditions: High temperature High power Slow power supply fan Low voltage Power supply is installed in the chassis but was disconnected from the power source amber (10 seconds) then amber Power supply is installed without a connection to a power source. Power supply failure possibly one of the following conditions: Over voltage Over current Over temperature Power supply fan failure 6

One of the following problems exist: At least one power supply LED is red. At least one power supply is down. Fan trays are all operational.

One of the following problems exist: At least one power supply LED is red. At least one power supply is down. Fan trays are all operational. Chassis This appendix includes the following topics: Chassis, on page 1 Supervisor Module, on page 2 I/O Module, on page 4 Fabric Module, on page 6 Fan Tray, on page 6 Power Supply, on page 7 Chassis PSU

More information

Managing Modules. About Modules. Send documentation comments to CHAPTER

Managing Modules. About Modules. Send documentation comments to CHAPTER CHAPTER 19 This chapter describes how to manage switching and services modules (also known as line cards) and provides information on monitoring module states. This chapter includes the following sections:

More information

Cisco MDS 9250i Multiservice Fabric Switch Overview. Introduction CHAPTER

Cisco MDS 9250i Multiservice Fabric Switch Overview. Introduction CHAPTER CHAPTER 1 Cisco MDS 9250i Multiservice Fabric Switch Overview This chapter describes the Cisco MDS 9250i Multiservice Fabric Switch and includes these topics: Introduction, page 1-1 Chassis Description,

More information

Advanced security capabilities like ETA, MACSec-256 and TrustWorthy systems.

Advanced security capabilities like ETA, MACSec-256 and TrustWorthy systems. The Cisco Catalyst 9500 Series Switches family consists of fixed core and aggregation layer switches supporting redundant power supplies and modular fans. The Cisco Catalyst 9500 Series offers switch models

More information

Product Overview. Switch Features. Catalyst 4503 Switch Features CHAPTER

Product Overview. Switch Features. Catalyst 4503 Switch Features CHAPTER CHAPTER This chapter provides an overview of the features and components of the Catalyst 4500 series switches. The Catalyst 4500 series switches are the Catalyst 4503 switch, the Catalyst 4506 switch,

More information

Troubleshooting CHAPTER

Troubleshooting CHAPTER CHAPTER 5 If your system has problems during start up or operation, use the information in this chapter to help isolate the cause. Problems with the initial startup are often caused by a switching module

More information

System Specifications

System Specifications Environmental s, on page 1 Switch Dimensions, on page 1 Weights for the Chassis, Modules, Fan Trays, and Power Supplies, on page 2 Power s, on page 3 Environmental s Environment Temperature Relative humidity

More information

This table describes the supervisor module options for switches in the Cisco MDS 9000 Family.

This table describes the supervisor module options for switches in the Cisco MDS 9000 Family. This chapter describes how to manage switching and services modules (also known as line cards) and provides information on monitoring module states. About Modules, page 1 Maintaining Supervisor Modules,

More information

System Specifications

System Specifications Environmental Specifications, page 1 Switch Dimensions, page 1 Weights and Quantities for the Chassis, Modules, Fan Trays, and Power Supplies, page 2 Power Specifications, page 4 Environmental Specifications

More information

Product Overview. Cisco 7600 Series Routers. Supported Hardware CHAPTER

Product Overview. Cisco 7600 Series Routers. Supported Hardware CHAPTER CHAPTER This chapter describes the Cisco 7600 series routers, supervisor engines, Optical Services Modules (OSMs), recommended Catalyst 6500 family modules, Ethernet Services 0G line cards, and SPA interface

More information

Initial Configuration

Initial Configuration CHAPTER 2 This chapter provides Cisco NX-OS best practices that are that typically configured when a Cisco Nexus 7000 Series switch is powered up for the first time and the user is connected to the RS-232

More information

System Specifications

System Specifications Environmental s, on page 1 Switch Dimensions, on page 1 Weights for the Chassis, Modules, Fan Trays, and Power Supplies, on page 2 Power s, on page 4 Environmental s Environment Temperature Relative humidity

More information

Installing or Replacing Modules, Fan Trays, and Power Supplies

Installing or Replacing Modules, Fan Trays, and Power Supplies Installing or Replacing Modules, Fan Trays, and Power Supplies This chapter includes the following topics: Using an ESD Wrist Strap to Prevent ESD Damage, page 1 Installing or Replacing a Supervisor Module,

More information

Troubleshooting the Installation

Troubleshooting the Installation This chapter contains general troubleshooting information to help isolate the cause of any difficulties you might encounter during the installation and initial startup of the system. Although an overtemperature

More information

ERX System Overview. The ERX System. This chapter provides information about the system.

ERX System Overview. The ERX System. This chapter provides information about the system. ERX System Overview 1 This chapter provides information about the system. Topic Page The ERX System 1-1 Where the ERX System Fits In 1-6 ERX System Modules 1-7 Network Management Tools 1-11 Redundancy

More information

Power is being correctly input. The power supply is absent or has input voltage error. The power supply is correctly outputting power.

Power is being correctly input. The power supply is absent or has input voltage error. The power supply is correctly outputting power. Contents Appendix B LEDs 1 Power supply LEDs 1 Fan LEDs 1 MPU LEDs 2 CF card status LED 2 Network management port LEDs 2 LPU status LEDs 3 MPU status LEDs 3 LPU LEDs 3 LINK/ACT LED 3 LINK and ACT LEDs

More information

High Availability and Redundant Operation

High Availability and Redundant Operation This chapter describes the high availability and redundancy features of the Cisco ASR 9000 Series Routers. Features Overview, page 1 High Availability Router Operations, page 1 Power Supply Redundancy,

More information

Troubleshooting. General System Checks. Troubleshooting Components. Send documentation comments to

Troubleshooting. General System Checks. Troubleshooting Components. Send documentation comments to APPENDIX B This appendix describes how to troubleshoot the Cisco MDS 9020 Fabric hardware installation, and it includes the following information: General System Checks, page B-1 Components, page B-1 Identifying

More information

Dell SCv3000 and SCv3020 Storage System Owner s Manual

Dell SCv3000 and SCv3020 Storage System Owner s Manual Dell SCv3000 and SCv3020 Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

Server-Related Faults

Server-Related Faults This chapter contains the following sections: fltadapterunitmissing, page 2 fltcomputeboardcmosvoltagethresholdcritical, page 2 fltcomputeboardcmosvoltagethresholdnonrecoverable, page 3 fltcomputeboardmotherboardvoltagelowerthresholdcritical,

More information

Managing Blade Servers

Managing Blade Servers This chapter includes the following sections: Blade Server Management, page 2 Guidelines for Removing and Decommissioning Blade Servers, page 2 Recommendations for Avoiding Unexpected Server Power Changes,

More information

Calculating the Power Consumption of Your EX8208 Switch Configuration

Calculating the Power Consumption of Your EX8208 Switch Configuration Calculating Power Requirements for an EX8208 Switch Use the information in this topic to calculate power consumption, system thermal output, and number of power supplies required for different EX8208 switch

More information

This document describes troubleshooting techniques for the Nexus 7000 (N7K) hardware.

This document describes troubleshooting techniques for the Nexus 7000 (N7K) hardware. Contents Introduction Debugging Chassis Issues Fan Issues Power Supply Temperature or Heat Debugging Supervisor Module Issues Switch/Supervisor Reset/Reload Active Supervisor Bring-up Standby Supervisor

More information

Catalyst 6500 Series Wireless LAN Services Module Installation and Verification Note

Catalyst 6500 Series Wireless LAN Services Module Installation and Verification Note Catalyst 00 Series Wireless LAN Services Module Installation and Verification Product number: WS-SVC-WLAN--K This document provides installation procedures for the Catalyst 00 series Wireless LAN Services

More information

SwitchBlade Switch Controller Quick Install Guide

SwitchBlade Switch Controller Quick Install Guide SwitchBlade Switch Controller Quick Install Guide SwitchBlade Switch Controller Quick Install Guide Document Number. Copyright 2002-2005 Allied Telesyn International, Corp. 19800 North Creek Parkway, Suite

More information

Chassis Overview. About the Cisco NCS 4016 Chassis. This chapter provides an overview of the Cisco NCS 4016 chassis and components.

Chassis Overview. About the Cisco NCS 4016 Chassis. This chapter provides an overview of the Cisco NCS 4016 chassis and components. This chapter provides an overview of the Cisco NCS 4016 chassis and components. About the Cisco NCS 4016 Chassis, page 1 Chassis Components, page 6 Chassis Cable Management, page 11 Safety Guidelines,

More information

Installing the IPS 4345 and IPS 4360

Installing the IPS 4345 and IPS 4360 CHAPTER 4 Installing the IPS 4345 and IPS 4360 Contents This chapter describes the Cisco IPS 4345 and the IPS 4360, and includes the following sections: Installation Notes and Caveats, page 4-1 Product

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0 SAS to SAS/SATA JBOD Subsystem Revision 1.0 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Terminologies... 6 Chapter 2 Getting Started... 7 2.1 Unpacking

More information

Troubleshooting. LEDs CHAPTER

Troubleshooting. LEDs CHAPTER CHAPTER 4 Revised: August 4, 2008, This chapter describes how to troubleshoot the Cisco VGD 1T3 Voice Gateway by referring to the LEDs on feature cards and using the bantam jack ports. The chapter contains

More information

DGS-1510 Series Gigabit Ethernet SmartPro Switch Web UI Reference Guide. Figure 10-1 Cable Diagnostics window

DGS-1510 Series Gigabit Ethernet SmartPro Switch Web UI Reference Guide. Figure 10-1 Cable Diagnostics window 10. OAM Cable Diagnostics DDM Cable Diagnostics The cable diagnostics feature is designed primarily for administrators or customer service representatives to verify and test copper cables; it can rapidly

More information

Troubleshooting. Diagnosing Problems

Troubleshooting. Diagnosing Problems Troubleshooting 8 This chapter explains how you can troubleshoot a specific problem at system power-up, such as abnormal LED activity or no system power. Topic Page Diagnosing Problems 8-1 Troubleshooting

More information

Quanta JB9 (M4600H) JBOD System Overview

Quanta JB9 (M4600H) JBOD System Overview JBOD System Overview System Specification Enclosure Form Factor HDD Support Host Interface Hot-Swap and Redundancy Controller Module Disk Drives Cooling Fans Power Supply Monitoring and Notification LED

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

Troubleshooting. Introduction CHAPTER

Troubleshooting. Introduction CHAPTER CHAPTER 8 Troubleshooting Revised: December 21, 2012, Introduction Your Cisco SCE 8000 GBE platform went through extensive testing before leaving the factory. However, if you encounter problems starting

More information

Dell EMC PowerEdge MX7000 Enclosure

Dell EMC PowerEdge MX7000 Enclosure Dell EMC PowerEdge MX7000 Enclosure Technical Specifications Regulatory Model: E44S Regulatory Type: E44S001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2 SAS to SAS/SATA JBOD Subsystem Revision 1.2 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Subsystem... 6 1.4 Identifying Parts

More information

Power Management in Cisco UCS

Power Management in Cisco UCS Power Capping in Cisco UCS, page 2 Power Policy Configuration, page 3 Power Policy for Cisco UCS Servers, page 3 Configuring the Power Policy, page 3 Power Supply for Redundancy Method, page 4 Configuring

More information

Product Overview. Send documentation comments to CHAPTER

Product Overview. Send documentation comments to CHAPTER Send documentation comments to mdsfeedback-doc@cisco.com CHAPTER 1 The Cisco MDS 9100 Series Multilayer Fabric Switches provide an intelligent, cost-effective, and small-profile switching platform for

More information

Configuring Platform Event Filters

Configuring Platform Event Filters This chapter includes the following sections: Platform Event Filters, page 1 Enabling Platform Event Alerts, page 1 Disabling Platform Event Alerts, page 2, page 2 Configuring SNMP Trap Settings, page

More information

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Regulatory Model: E03J, E04J Regulatory Type: E03J001, E04J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that

More information

Dell SC7020 and SC7020F Storage Systems Owner s Manual

Dell SC7020 and SC7020F Storage Systems Owner s Manual Dell SC7020 and SC7020F Storage Systems Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates

More information

Dell EMC ME4 Series JBOD 5U84 Enclosure

Dell EMC ME4 Series JBOD 5U84 Enclosure Dell EMC ME4 Series JBOD 5U84 Enclosure Deployment Guide Regulatory Model: E09J, E10J, E11J Regulatory Type: E09J001, E10J001, E11J001 Notes, cautions, and warnings NOTE: A NOTE indicates important information

More information

Installing the MWAM CHAPTER

Installing the MWAM CHAPTER CHAPTER This chapter provides information about installing the MWAM in a Catalyst 600/Cisco 7600 chassis and includes the following topics: Safety Recommendations, page -2, page - Verifying the Installation,

More information

H3C SecPath M9000-S NSQM2MPUD0 main processing unit

H3C SecPath M9000-S NSQM2MPUD0 main processing unit H3C SecPath M9000-S NSQM2MPUD0 main processing unit 1 Identifier The module identifier NSQM2MPUD0 is at the upper right corner of the front panel. 2 The NSQM2MPUD0 MPU has a console port, a USB port, a

More information

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules This document provides the installation and removal instructions for the AC and DC input power supply and fan modules

More information

SCv3000 and SCv3020 Storage System. Owner s Manual

SCv3000 and SCv3020 Storage System. Owner s Manual SCv3000 and SCv3020 Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

TelePresence MCU Hardware Troubleshoot Guide

TelePresence MCU Hardware Troubleshoot Guide TelePresence MCU Hardware Troubleshoot Guide Document ID: 116839 Contributed by Cisco TAC Engineers. Dec 17, 2013 Contents Introduction Prerequisites Requirements Components Used Related Products Cisco

More information

ARX 2000 / D108 RMA4 Replacement Script Full Appliance March 20, 2011 Version 1.03

ARX 2000 / D108 RMA4 Replacement Script Full Appliance March 20, 2011 Version 1.03 ARX 2000 / D108 RMA4 Replacement Script Full Appliance March 20, 2011 Version 1.03 Index ARX2000 Chassis Overview Front with Bezel... 2 Status and Alarm LEDs... 3 ARX2000 Chassis Overview Back... 5 ARX

More information

Dell SC5020 and SC5020F Storage System Owner s Manual

Dell SC5020 and SC5020F Storage System Owner s Manual Dell SC5020 and SC5020F Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

Troubleshooting the Installation

Troubleshooting the Installation This chapter contains general troubleshooting information to help isolate the cause of any difficulties you might encounter during the installation and initial startup of the system. Although an over-temperature

More information

Troubleshooting Initial Startup Problems

Troubleshooting Initial Startup Problems Your Cisco ASR 1000 Series Router went through extensive testing before leaving the factory. However, if you encounter problems starting the router, use the information in this chapter to help isolate

More information

Contents. Introduction. Prerequisites. Overview. Requirements. Components Used

Contents. Introduction. Prerequisites. Overview. Requirements. Components Used Contents Introduction Prerequisites Requirements Components Used Overview Troubleshoot Failure reported by DC Power Supply (A900-PWR550-D) Failure reported by Fan Tray Scenario 1: Individual Fan module

More information

Managing Individual Components

Managing Individual Components CHAPTER 3 This chapter describes how to install the Field Replaceable Units (FRUs) in the Cisco SFS 7008P system. About the Field Replaceable Units The following Field Replaceable Units (FRUs) are a part

More information

Dell PowerVault MD3060e Storage Enclosure Owner's Manual

Dell PowerVault MD3060e Storage Enclosure Owner's Manual Dell PowerVault MD3060e Storage Enclosure Owner's Manual Regulatory Model: E08J Series Regulatory Type: E08J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you

More information

Maintaining the Cisco Catalyst 5500 Multiswitch Router

Maintaining the Cisco Catalyst 5500 Multiswitch Router 7 CHAPTER Maintaining the Cisco Catalyst 5500 Multiswitch Router Revised: December 3, 2009, This chapter contains recommended hardware maintenance procedures for the Cisco Catalyst 5500 Multiswitch Routers

More information

Troubleshooting the Installation

Troubleshooting the Installation CHAPTER 4 Overview The Cisco 12404 Internet router undergoes extensive testing and burn-in before leaving the factory However, if you encounter problems starting up the router, use the information in this

More information

Vector Drive - Troubleshooting Guide

Vector Drive - Troubleshooting Guide Haas Technical Documentation Vector Drive - Troubleshooting Guide Scan code to get the latest version of this document Translation Available The Haas Vector drive is the source of power for the spindle

More information

14.5U 4X SDR/DDR InfiniBand Switch Platform User s Manual. Rev 0.10

14.5U 4X SDR/DDR InfiniBand Switch Platform User s Manual. Rev 0.10 14.5U 4X SDR/DDR InfiniBand Switch Platform User s Manual 2 Copyright 2007. International and its licensors. All rights reserved. 14.5U 4X SDR/DDR InfiniBand Switch Platform User s Manual 3 Contents Contents

More information

WARNING!!!!!!!!! IMPORTANT INFORMATION: READ BEFORE INSTALLATION!

WARNING!!!!!!!!! IMPORTANT INFORMATION: READ BEFORE INSTALLATION! V_Net Relay Module Installation Instructions: Part Number: 230-VM-RELAY WARNING!!!!!!!!! IMPORTANT INFORMATION: READ BEFORE INSTALLATION! The relay outputs of the 230-VM-RELAY module may turn on when not

More information

Managing System Hardware

Managing System Hardware CHAPTER 18 This chapter provides details on how to manage system hardware other than services and switching modules and how to monitor the health of the switch. It includes the following sections: Displaying

More information

Maintaining the Cisco Internet Router

Maintaining the Cisco Internet Router CHAPTER 5 Maintaining the Cisco 12404 Internet Router Overview This chapter contains safety at the field replaceable unit (FRU) level, removal and replacement instructions for FRUs and procedures to troubleshoot

More information

This chapter describes the power management feature in the Catalyst enterprise LAN switches.

This chapter describes the power management feature in the Catalyst enterprise LAN switches. 28 CHAPTER This chapter describes the power management feature in the Catalyst enterprise LAN switches. For complete syntax and usage information for the commands that are used in this chapter, refer to

More information

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0 64 Bays SAS to SAS/SATA JBOD Subsystem Revision 1.0 Table of Contents Preface... 4 Before You Begin... 5 Safety Guidelines... 5 Controller Configurations... 5 Packaging, Shipment and Delivery... 5 Unpacking

More information

Product Overview. Cisco ME 6524 Ethernet Switch (ME-C6524GS-8S) CHAPTER

Product Overview. Cisco ME 6524 Ethernet Switch (ME-C6524GS-8S) CHAPTER 2 7 CHAPTER This chapter describes the Cisco ME 00 series Ethernet switches and contains these sections: Cisco ME 2 Ethernet Switch (ME-C2GS-8S), page - Cisco ME 2 Ethernet Switch (ME-C2GT-8S), page -7

More information

This section describes the software and hardware requirements for the module.

This section describes the software and hardware requirements for the module. CHAPTER 2 This chapter describes the requirements to support the Catalyst 6500 series and Cisco 7600 series and Catalyst 6000 family NAM, and how to install and remove the NAM, and includes these sections:

More information

Cisco CRS-1 Carrier Routing System 16-Slot Line Card Chassis Hardware Operations and Troubleshooting Guide

Cisco CRS-1 Carrier Routing System 16-Slot Line Card Chassis Hardware Operations and Troubleshooting Guide Cisco CRS-1 Carrier Routing System 16-Slot Line Card Chassis Hardware Operations and Troubleshooting Guide This guide assists users of the Cisco CRS-1 16-Slot Line Card Chassis with properly operating,

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1 SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying

More information

BITMAIN. S2 Server Manual

BITMAIN. S2 Server Manual BITMAIN S2 Server Manual Page 2 of 10 Contents 1 Overview... 3 2 Connect to Server... 4 3 Pool Setting... 5 4 Server Status... 6 5 System Configuration and status... 7 5.1 System Upgrading... 7 5.2 Password

More information

Configuring Online Diagnostics

Configuring Online Diagnostics Configuring Online s This chapter contains the following sections: Information About Online s, page 1 Guidelines and Limitations for Online s, page 4 Configuring Online s, page 4 Verifying the Online s

More information

Configuring Platform Event Filters

Configuring Platform Event Filters This chapter includes the following sections: Platform Event Filters, page 1 Enabling Platform Event Alerts, page 1 Disabling Platform Event Alerts, page 2, page 2 Configuring SNMP Trap Settings, page

More information

A0750 AC-DC POWER MODULE

A0750 AC-DC POWER MODULE FEATURES High power density, 7.7W / in³ Net Weight:< 2.2 KG Low profile : 40.8mm (fit 1U 19 shelf R2250 series) Efficiency: 77% ~ 86 % typical Power factor correction (meet IEC1000-3-2 requirements) Overvoltage

More information

Product Overview. Switch Model

Product Overview. Switch Model Switch Models The Catalyst 3850 family of switches are Ethernet switches to which you can connect devices such as Cisco IP Phones, Cisco Wireless Access Points, workstations, and other network devices

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1 SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying

More information

Vector Drive - Troubleshooting Guide

Vector Drive - Troubleshooting Guide Haas Technical Documentation Vector Drive - Troubleshooting Guide Scan code to get the latest version of this document Translation Available The Haas Vector drive is the source of power for the spindle

More information

Vector Drive - Troubleshooting Guide

Vector Drive - Troubleshooting Guide Haas Technical Documentation Vector Drive - Troubleshooting Guide Scan code to get the latest version of this document Translation Available The Haas Vector drive is the source of power for the spindle

More information

Cisco CRS-1 Carrier Routing System

Cisco CRS-1 Carrier Routing System CHAPTER This site planning guide describes how to plan and prepare your site facilities for the installation of a 8-Slot Line Card Chassis (also referred to in this document as the Cisco CRS- 8-slot line

More information

McAfee Data Loss Prevention

McAfee Data Loss Prevention Hardware Guide Revision B McAfee Data Loss Prevention Models 4400, 5500, 6600 This guide describes the features and capabilities of McAfee Data Loss Prevention (McAfee DLP) appliances to help you to manage

More information

Cisco Nexus 7000 Switches Supervisor Module

Cisco Nexus 7000 Switches Supervisor Module Data Sheet Cisco Nexus 7000 Switches Supervisor Module Data Sheet The Cisco Nexus 7000 Switches Supervisor Module (Figure 1) scales the control plane and data plane services for the Cisco Nexus 7000 Switches

More information

Installation Manual. Table of Contents

Installation Manual. Table of Contents Table of Contents Table of Contents... 1-1 1.1 Introduction... 1-1 1.1.1 Introduction to S7500 Series Ethernet Switches... 1-1 1.1.2 Introduction to Switching Engines... 1-2 1.2 Technical Specifications

More information

Dell EMC PowerVault MD3460 Storage Arrays

Dell EMC PowerVault MD3460 Storage Arrays Dell EMC PowerVault MD3460 Storage Arrays Owner's Manual Regulatory Model: E08J Series Regulatory Type: E08J001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you

More information

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems.

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems. DNS-2670 User Manual Version Dec. 2015 DataON Storage, storage division of Area Data Systems. Contents 1 Introduction... 1 1.1 System Overview... 3 1.1.1 System Top View...3 1.1.2 Front View...4 1.1.3

More information

Overview. Features CHAPTER

Overview. Features CHAPTER CHAPTER 2 This chapter provides these topics that describe the Catalyst 2955 switch, hereafter referred to as the switch. Features, page 2-1 Front-Panel Description, page 2-3 Rear-Panel Description, page

More information

Chassis (FRU) Replacement Guide

Chassis (FRU) Replacement Guide SIEM9750 Release 1.0 Chassis (FRU) Replacement Guide Issue: 02 Date: 2011-11-07 Page 1 of 26 This document is intended for Symantec support personnel, IBM, or other authorized Symantec Service Partners.

More information

Abstract. Avaya Solution & Interoperability Test Lab

Abstract. Avaya Solution & Interoperability Test Lab Avaya Solution & Interoperability Test Lab Application Notes for the Force10 Networks C-Series C300 Switch Supporting Power over Ethernet with Avaya Communication Manager, Avaya G11 PSTN Gateway and Avaya

More information

Automation Interface Requirements for System I/O Interface of a DPC I Welding System

Automation Interface Requirements for System I/O Interface of a DPC I Welding System - 1 - Automation Interface Requirements for System I/O Interface of a DPC I Welding System The DPC I welding system offer several features that are intended to communicate with automation. These features

More information

Route Processor. Route Processor Overview. This chapter describes the route processor (RP) card. The following sections are included:

Route Processor. Route Processor Overview. This chapter describes the route processor (RP) card. The following sections are included: This chapter describes the route processor (RP) card. The following sections are included: Overview, page 1 Primary and Standby Arbitration, page 4 RP Card to Fabric Module Queuing, page 4 Performance,

More information

Dell EMC Storage MD1280 Enclosure Owner's Manual

Dell EMC Storage MD1280 Enclosure Owner's Manual Dell EMC Storage MD1280 Enclosure Owner's Manual Regulatory Model: SP-2584, E11J Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product.

More information

Monitoring the System

Monitoring the System This chapter provides information for monitoring system status and performance using the show commands found in the Command Line Interface (CLI). These command have many related keywords that allow them

More information

Sidewinder Control Center. Hardware Guide Models C1015, C2050, and C3000. Revision C

Sidewinder Control Center. Hardware Guide Models C1015, C2050, and C3000. Revision C Sidewinder Control Center Hardware Guide Models C1015, C2050, and C3000 Revision C Table of contents Preface...3 Find product documentation... 3 1 Introducing the appliances... 4 Model features...4 Network

More information

Overview. Port Adapter Overview CHAPTER

Overview. Port Adapter Overview CHAPTER CHAPTER This chapter describes the V. synchronous serial port adapter (PA-8T-V[=]) and contains the following sections: Port Adapter, page - Serial Interface Specifications, page - LEDs, page - Cables

More information

BlackDiamond 8800 Series Switches Hardware Installation Guide

BlackDiamond 8800 Series Switches Hardware Installation Guide BlackDiamond 8800 Series Switches Hardware Installation Guide Extreme Networks, Inc. 3585 Monroe Street Santa Clara, California 95051 (888) 257-3000 (408) 579-2800 http://www.extremenetworks.com Published:

More information

Dell OpenManage Connection for Tivoli Enterprise Console Version 3.5. User s Guide. support.dell.com

Dell OpenManage Connection for Tivoli Enterprise Console Version 3.5. User s Guide.   support.dell.com Dell OpenManage Connection for Tivoli Enterprise Console Version 3.5 User s Guide www.dell.com support.dell.com Notes and Notices NOTE: A NOTE indicates important information that helps you make better

More information

Send documentation feedback to

Send documentation feedback to CHAPTER 1 This chapter provides solutions to the problems that you could encounter when running the Cisco Connected Grid Design Suite - Substation Workbench (CGDS Substation Workbench). CGDS Designer,

More information

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved. apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May 2004 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc.

More information

Cisco Nexus 9500 Series Switches

Cisco Nexus 9500 Series Switches Data sheet Cisco Nexus 9500 Series Switches Product overview Application architectures and deployment modes are rapidly evolving. Modern applications are multinode, highly modular, and deployed over a

More information

Product Overview. Physical and Functional Description of Router CHAPTER1

Product Overview. Physical and Functional Description of Router CHAPTER1 CHAPTER1 This chapter provides an overview of the Cisco XR 12416 and Cisco XR 12816 Router. It contains physical descriptions of the router hardware and major components, as well as functional descriptions

More information

Cisco Nexus 9500 Platform Switches for Cisco Application Centric Infrastructure

Cisco Nexus 9500 Platform Switches for Cisco Application Centric Infrastructure Data Sheet Cisco Nexus 9500 Platform Switches for Cisco Application Centric Infrastructure Product Overview Changing application environments are creating new demands on the IT infrastructure that supports

More information

DNS-2608 Enterprise JBOD Enclosure User Manual

DNS-2608 Enterprise JBOD Enclosure User Manual DNS-2608 Enterprise JBOD Enclosure User Manual Nov.2017 Copyright DataON. All rights reserved. www.dataonstorage.com 1 Contents Package Contents... 3 System Requirements... 3 Technical Support... 3 DataON

More information

PEM Faults and Blower Failures

PEM Faults and Blower Failures CHAPTER 2 The following sections provide methods for troubleshooting faults involving the Cisco 10000 series router Power Entry Modules (PEMs) and blower modules. This chapter contains the following major

More information

Managing Power in Cisco UCS

Managing Power in Cisco UCS Managing Power in Cisco UCS This chapter includes the following sections: Power Management in Cisco UCS, page 1 Configuring the Power Policy, page 1 Configuring the Global Cap Policy, page 2 Configuring

More information