REMOTE CONTROL MYSYSTEM

Size: px
Start display at page:

Download "REMOTE CONTROL MYSYSTEM"

Transcription

1 REMOTE CONTROL MYSYSTEM

2 GENERAL FEATURES... 3 MAIN FUNCTIONS AND EQUIPMENT:... 3 LCD DISPLAY... 4 KEYBOARD:... 5 MAIN LOGIC... 6 BOARD CONFIGURATION... 7 MAIN PARAMETERS LIST:... 7 MAIN PARAMETERS CONFIGURATION:... 7 ADVANCED CONFIGURATION... 9 ADVANCED PARAMETERS LIST:... 9 ADVANCED PARAMETERS CONFIGURATION:... 9 ALARMS PROBE ALARMS: CIRCUIT BOARD WALL INSTALLATION OF CONTROL TECHNICAL DATA RG REV.01

3 GENERAL FEATURES MySystem is designed to manage heat pump on/off, a modulating valve and an integrative / replacement boiler MAIN FUNCTIONS AND EQUIPMENT: Switches unit on/off. Displays water valve temperature Displays outdoor air temperature Switches boiler on/off. Modulating valve control The control panel includes: 3 RG REV.01

4 LCD display keyboard LCD DISPLAY Evaporator outlet water temperature 2 Outdoor air temperature 3 Modulating valve setpoint Mysystem on Mysystem off Operation mode: Cooling. Operation mode: Heating. Alarm present Heat Pump active Celsius / Fahrenheit visualization Boiler active Backlighting turns on whenever any button is pressed and turns off automatically about 2 minutes after the last key was pressed 4 RG REV.01

5 KEYBOARD: ON/OFF key: Switching the unit on/off. When changing user parameters, it allows to return to normal operation. the key does not work when the digital input ON/OFF is active UP and DOWN keys: changes setpoint. used when changing parameters to select the parameters or to change values. SEL key: accesses parameters change / selection confirmation MODE key: Selection of Heating / Cooling operation mode (2 different setpoints for modulating valve) ECO key: cancel parameter change Active key combinations: Access to parameter configuration procedure Displays opening valve % Change Celsius / Fahrenheit visualization 5 RG REV.01

6 MAIN LOGIC MySystem can manage an heat pump and an integrative/replacement boiler at the same time acting on digital contacts. Heat pump switching off and boiler switching on are individually settable on external air threshold. Choosing setpoint equal to differential allows an integrative logic, otherwise, crossing the two phases, allows a replacement logic. Modulating valve regulation works on water probe reading and consists of a dead zone around setpoint with no regulation, the next zone has a regulating step (ual PErC) and a modulating time (ual tiπe) settable by parameter. Regulations zones are settable by dead zone parameter ( Zn dead ) and modulating valve differential ( ual Diff ) parameter. Outside that area regulation is fast with step: (ual PErC) * (ΠuL FACt) And time: (ual tiπe) / (diu FACt) ACCURATE REGULATION NO REGULATION ACCURATE REGULATION FAST REGULATION FAST REGULATION SET - DIFF SET ZN/2 SETPOINT SET + ZN/2 SET + DIFF 6 RG REV.01

7 BOARD CONFIGURATION MAIN PARAMETERS LIST: DIGITAL INPUT CONFIGURATION (din ConF): configuration of DIN 1/2 0: DIN1 = - DIN2 = - 1: DIN1 = On/Off DIN2 = - 2: DIN1 = - DIN2 = Sum/Win 3: DIN1 = On/Off DIN2 = Sum/Win DIN1 LOGIC (di1 Log): 0: [open/closed] = [Off/On] 1: [open/closed] = [On/Off] DIN2 LOGIC (di2 Log): 0: [open/closed] = [-/Sum/Win] 1: [open/closed] = [Sum/Win /-] MODULATING VALVE LOGIC (ual LoG): 0: n.o. 1: n.c. DO1 LOGIC (do1 Log): 0: n.o. 1: n.c. DO2 LOGIC (do2 Log): 0: n.o. 1: n.c. MAIN PARAMETERS CONFIGURATION: simultaneously press the keys 7 RG REV.01

8 use the keys to change the value of the display to the value of the password 10, then press. If correct, you can access the parameters use the keys to scroll the various parameters (see Parameter List described above) press to activate the parameter change (the value will flash) use keys to change the value press to save the new value set or to cancel the change once the concerned parameters have been changed, press the key to exit the procedure 8 RG REV.01

9 ADVANCED CONFIGURATION ADVANCED PARAMETERS LIST: ON BOILER SETPOINT (Set boil) OFF BOILER DIFFERENTIAL (dif boil) OFF HEAT PUMP SETPOINT (SEt PdC) ON HEAT PUMP DIFFERENTIAL (dif PdC) WATER PROBE OFFSET (H2O offs) AIR PROBE OFFSET (Air offs) MODULATING VALVE REGULATION % (ual PErC) : Sets modulating valve % variation. Less the value, more accurate the regulation. MODULATING VALVE REGULATION TIME (ual time) : Sets modulating valve regulating step (in seconds) DEAD ZONE (Zn dead) MODULATING VALVE DIFERENTIAL (ual diff) MODULATING VALVE MULTIPLICATION FACTOR (ΠuL FACt) MODULATING VALVE DIVISION FACTOR (diu FACt) ADVANCED PARAMETERS CONFIGURATION: simultaneously press the keys 9 RG REV.01

10 use the keys to change the value of the display to the value of the password 77, then press. use the keys to scroll the various parameters (see Advanced Parameter List described above) press to activate the parameter change (the value will flash) use keys to change the value press to save the new value set or to cancel the change once the concerned parameters have been changed, press the key to exit the procedure 10 RG REV.01

11 ALARMS PROBE ALARMS: In case of control alarm due to probes malfunctioning, display will visualize the error message. This condition will continue until the alarm has terminated. flashing symbol and an WATER PROBE ALARM AIR PROBE ALARM CIRCUIT BOARD Vc Vh V0 V1 V2 V3 N N L PE B GND A SU SU SW SW SA SA 101 COM 102 DO2 DO1 CO12 DI1 CI12 DI2 A-B-GND RS 485 N Neutral L Phase PE Earth DI1 On/Off digital input (optional) CI12 Dig.1-2 Common DI2 Sum/Win digital input (optional) DO1 Digital output 1 (Boiler) DO2 Digital output 2 (heat pump) CO12 DO1-2 Common SW Water temperature probe SA Air temperature probe 101 Analog output 0-10V (modulating valve) COM Analog output common NB: o for power connection, use 1 mm 2 section cable o for digital inputs, use AWG 24 cables o for probe extensions and RS485, use AWG 24 shielded cables 11 RG REV.01

12 WALL INSTALLATION OF CONTROL NB: for wall installation, it is recommended to use an electrical box behind the control to house the wires. NB: before installation, carefully remove the protective film on the display. Film removal may cause dark halos to show up on the display which will disappear in a few seconds and are not a sign of a defect. Instructions for wall installation 1. Remove the control's closing screw. Fig If a 503 electrical enclosure is used, pass the cables through the slot at the bottom of the control and use the holes provided for fastening. Fig Otherwise drill holes in the wall where you would like to install the control, matching the fastening slots (5 x 8 mm) at the bottom of the control. Pass the cables through the slots at the bottom and fix it to the previously drilled holes in the wall with screws. 12 RG REV.01

13 Fig Perform the electrical connections on the terminal board following the relative electrical layout. 5. Close the control fastening the screw removed in point RG REV.01

14 TECHNICAL DATA 14 RG REV.01

15 15 RG REV.01

16 16 RG REV.01

4-step Chiller and Heat Pump Controller

4-step Chiller and Heat Pump Controller 4-step Chiller and Heat Pump Controller Technical Data Sheet GENERAL DESCRIPTION MODELS CODE MODEL DESCRIPTION MW324000 ECH 420 HEAT PUMP WITH 4 STEPS/ 2 CIRCUITS + MODBUS MW324005 ECH 420/V WITH SCREW

More information

User Guide. For controller on CXAO / RTXB heat pumps CGCM / CXCM 2 circuit units. CNT-SVU005C-GB Original instructions

User Guide. For controller on CXAO / RTXB heat pumps CGCM / CXCM 2 circuit units. CNT-SVU005C-GB Original instructions User Guide For controller on CXAO / RTXB heat pumps CGCM / CXCM 2 circuit units CNT-SVU005C-GB Original instructions Table of contents Advanced electronics... 3 Technical Specifications... 4 Display description...

More information

OPERATION INSTRUCTIONS

OPERATION INSTRUCTIONS 2018 Lennox Industries Inc. Dallas, Texas, USA OPERATION INSTRUCTIONS V0STAT52 Wireless Indoor Unit Controller CONTROLS 507459-04 05/2018 This manual must be left with the owner for future reference. IMPORTANT

More information

System 450 Series Reset Control Modules with Real-Time Clock and Relay Output

System 450 Series Reset Control Modules with Real-Time Clock and Relay Output System 450 Series Reset Control Modules with Real-Time Clock and Relay Output Installation C450RBN-1 C450RCN-1 Part No. 24-7664-2772, Rev. B Issued November 4, 2010 Supersedes February 16, 2010 Application

More information

MXM-50. Modbus Interface for Mitsubishi Air-Conditioning. Installation and User Guide.

MXM-50. Modbus Interface for Mitsubishi Air-Conditioning. Installation and User Guide. MXM-50 Modbus Interface for Mitsubishi Air-Conditioning Installation and User Guide www.innon.co.uk 1. Product Overview The Black Pear MXM-50 unit allows a Modbus building management system (BMS) to monitor

More information

MM-A20 BMS Interface for Mitsubishi Electric Split Air-Conditioning

MM-A20 BMS Interface for Mitsubishi Electric Split Air-Conditioning MM-A20 BMS Interface for Mitsubishi Electric Split Air-Conditioning Installation and User Guide www.microtrol.co.uk Contents 1. Supplied Parts...2 2. Important Information...3 3. Product Overview...4

More information

Model: Available in : Sapphire Black and Glacier White

Model: Available in : Sapphire Black and Glacier White Model: Available in : Sapphire Black and Glacier White 1 Table of Contents Product Image 1 Locking/Unlocking the SmartStat 20 Table of Contents 2 Standby/Away Mode 21 What is a Programmable Room Thermostat?

More information

Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication.

Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication. HTC-DIGITAL-LCD Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication. Features Use Australian Made and designed LCD 2 X 16 Character Backlit Display Five Programmable

More information

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs

More information

User Guide. Multipipe Units CMAA / RTMA CNT-SVU004B-GB

User Guide. Multipipe Units CMAA / RTMA CNT-SVU004B-GB User Guide Multipipe Units CMAA / RTMA CNT-SVU004B-GB USER GUIDE WARNING Supply the unit at least 24 hours before the initial startup to heat the compressor oil. In conditions of low water temperature,

More information

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Iso DIN. User Manual. 1 channel Earth Fault Monitoring Page 1 of 5 2017 03 20 User Manual Iso DIN Iso DIN User Manual 1 channel Earth Fault Monitoring Megacon AB Ranhammarsvägen 20 S 168 67 Bromma Sweden Tel: 08 402 42 50 sales@megacon.se www.megacon.se eee

More information

USER S MANUAL. DAS-G01 The Power of Tomorrow

USER S MANUAL. DAS-G01 The Power of Tomorrow USER S MANUAL DAS-G01 The Power of Tomorrow Richmond Heights 2018 0 USER S MANUAL DAS-G01 The Power of Tomorrow Richmond Heights 2018 Page 1 USER'S MANUAL TABLE OF CONTENTS Page # 1.0 GENERAL INFORMATION...

More information

Model: Available in : Sapphire Black and Glacier White

Model: Available in : Sapphire Black and Glacier White 1 Model: Available in : Sapphire Black and Glacier White 1 Table of Contents Product Image 1 Locking/Unlocking the SmartStat 20 23 Table of Contents 2 Standby/Away Mode Mode 21 24 What is a Programmable

More information

TECHNICAL MANUAL WATER 300 C 5300 CV/06-00 GB

TECHNICAL MANUAL WATER 300 C 5300 CV/06-00 GB T E C H N I C A L M A N U A L TECHNICAL MANUAL C 5300 CV/06-00 GB GB The information contained in this document may be modified without prior notice and is in no way binding, even implicitly, for CLIMAVENETA.

More information

MAXDTC-BT Family User Manual

MAXDTC-BT Family User Manual MAXDTC-BT Family User Manual Description The MAXDTC-BT is a fully programmable industrial temperature controller. The controller is configurable and monitorable thru a Bluetooth connection from your Android

More information

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display HTC 5 Features Australian Made and designed Power can be either 24V or 240V AC 10 Amp (Resistive) Potential free relay contacts

More information

Control Cube T Digital Temperature Controller Operating Manual

Control Cube T Digital Temperature Controller Operating Manual Control Cube T Digital Temperature Controller Operating Manual Specifications Willhi WH7016+ digital thermostatic controller; 110vac; 30A relay Dual mode (heating or cooling) 13A maximum current rating

More information

Measure & Control Temperature & CO2 levels with analog & digital I/O

Measure & Control Temperature & CO2 levels with analog & digital I/O MADE IN OZ HTC-DIGITAL-LCD PROGRAMMABLE TEMPERATURE CONTROLLER c/w YEARLY PROGRAMMABLE TIME SWITCH COMPATIBLE WITH A WIDE RANGE OF SENSORS ROOM O/A WALL DUCT PIPE Use Features Measure & Control Temperature

More information

Quick Start Guide DDC (2014/02) Subject to change without prior notice Quick Start Guide

Quick Start Guide DDC (2014/02) Subject to change without prior notice Quick Start Guide Quick Start Guide 560/583 DDC 8733914716(2014/02) Please refer to the included Hardware User s Guide and BACview Installation and Operation Manual for more detailed information on setting up and using

More information

idigit CONTROL INSTALLER MANUAL Digital thermostat for fan coil units Rev100

idigit CONTROL INSTALLER MANUAL Digital thermostat for fan coil units Rev100 idigit CONTROL Digital thermostat for fan coil units INSTALLER MANUAL Termostato digital para ventiladores-convectores Thank you for trusting the Hitecsa Products. Our company has been offering the market

More information

Operations Manual HP2000. With 9100 Controller. Self-Heated Oxygen Measurement System

Operations Manual HP2000. With 9100 Controller. Self-Heated Oxygen Measurement System Operations Manual HP2000 With 9100 Controller Self-Heated Oxygen Measurement System Please read, understand, and follow these instructions before operating this equipment. Super Systems, Inc. is not responsible

More information

Smart heating system. with wireless thermostats & smartphone control for every room. Get the most out of any water based underfloor heating

Smart heating system. with wireless thermostats & smartphone control for every room. Get the most out of any water based underfloor heating Smart heating system with wireless thermostats & smartphone control for every room Get the most out of any water based underfloor heating DETAILED OVERVIEW Control the heating in your home from anywhere.

More information

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit Document No. 155-324 Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit Description Features Application Product Number Room temperature controller for four-pipe fan coil units.

More information

TPE, TPED Series 2000

TPE, TPED Series 2000 GRUNDFOS INSTRUCTIONS TPE, TPED Series 2000 Installation and operating instructions English (GB) English (GB) Installation and operating instructions Original installation and operating instructions. CONTENTS

More information

Installing VO2 Analog Output Boards

Installing VO2 Analog Output Boards Chapter 3-6 VO2 Description and Identification Installing VO2 Analog Output Boards The VO2 Variable Output board provides an AKC 55 system with 2 variable outputs for control of loads like variable speed

More information

Zone Manager INSTALLATION MANUAL 40KMC KMQ QNC QNQ

Zone Manager INSTALLATION MANUAL 40KMC KMQ QNC QNQ 40KMC------301 40KMQ------301 40QNC------3 40QNQ------3 INSTALLATION MANUAL Installation manual This control system only operates with indoor units of the following models: 40KMC------301 and 40KMQ------301

More information

PumpDrive. Self -cooling, motor-independent frequency inverter. Brief Instructions

PumpDrive. Self -cooling, motor-independent frequency inverter. Brief Instructions Brief Instructions PumpDrive 4070.801/2--11 Self -cooling, motor-independent frequency inverter Mounting variants: Motor mounting (MM) Wall mounting (WM) Cabinet mounting (CM) Brief Instructions 1 About

More information

USER'S GUIDE BARD-LINK TM LC /LC SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER & TEC-EYE HAND-HELD DIAGNOSTIC TOOL

USER'S GUIDE BARD-LINK TM LC /LC SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER & TEC-EYE HAND-HELD DIAGNOSTIC TOOL USER'S GUIDE BARD-LINK TM LC1000-100/LC1500-100 SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER & TEC-EYE HAND-HELD DIAGNOSTIC TOOL Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead,

More information

VTR8300 User Interface Guide VTR8300 Room Controller Series

VTR8300 User Interface Guide VTR8300 Room Controller Series VTR8300 User Interface Guide VTR8300 Room Controller Series CONTENTS Home Screen Display 2 How to Enter Setup Screen 3 Setup Screen Display 3 Network Settings 4 ZigBee Network Settings 4 BACnet Network

More information

RWD32S Software Tool. Operating Instructions. CE1U3344en Building Technologies

RWD32S Software Tool. Operating Instructions. CE1U3344en Building Technologies RWD32S Software Tool Operating Instructions CE1U3344en 25.06.2009 Building Technologies Siemens Switzerland Ltd Industry Sector Building Technologies Division International Headquarters HVAC Products Gubelstrasse

More information

Installation, Start-up and Operating Instructions

Installation, Start-up and Operating Instructions Installation, Start-up and Operating Instructions EVOLUTION SMART SENSOR FOR ZONING Cancels: NEW II ZONESMS-0-1 7-04 NOTE: Read the entire instruction manual before starting the installation. This symbol

More information

T7560A1036 Digital Wall Module

T7560A1036 Digital Wall Module T7560A1036 Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. T7560A1036

More information

Installation Manual RB-RWS20-E. Lite-Vision plus Remote Controller. Model name: English

Installation Manual RB-RWS20-E. Lite-Vision plus Remote Controller. Model name: English Model name: RB-RWS20-E Read this manual before using the RB-RWS20-E remote controller. Refer to the supplied with the indoor unit for any installation instructions other than operations of the remote controller.

More information

FCU-4 FAN COIL CONTROLLER

FCU-4 FAN COIL CONTROLLER FCU-4 FAN COIL CONTROLLER BACnet Enabled Description The FCU-4 is designed to provide complete control of fan coil units. The FCU-4 incorporates all the inputs and outputs to ensure that this advanced

More information

Temperature Controller (Heat Pumps)

Temperature Controller (Heat Pumps) 3 347 Temperature Controller (Heat Pumps) For comfort control in HVAC & R systems Standalone electronic controller Programmable controller with preconfigured applications Three universal inputs for Ni1000,

More information

CONDUCTOR W4. Installation instruction for W4.1 and W To mount the controller. Controller. Mounting on a DIN rail

CONDUCTOR W4. Installation instruction for W4.1 and W To mount the controller. Controller. Mounting on a DIN rail CONDUCTOR W Installation instruction for W. and W. 00 Controller To mount the controller. Mounting on a DIN rail Figure. Overview of the Controller. Pos. Product marking. Pos. Termination resistance. =

More information

RVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting

RVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting G2522en Heating controller Installation Instructions RVL470 1 Installation 1.1 Place of installation In a dry room, e.g. the boiler room Mounting choices: In a control panel (on the inner wall or on a

More information

USB-Link 2 Technical Guide

USB-Link 2 Technical Guide www.wattmaster.com USB-Link 2 Technical Guide USB-Link 2 Code: SS0073 Version 4.11 and up TABLE OF CONTENTS GENERAL INFORMATION... 3 USB-Link 2 Overview... 3 System Requirements... 3 QUICK GUIDE...4 USB-LINK

More information

REFRIGERATION AND AIR CONDITIONING. On Site Guide AK2-SC 255

REFRIGERATION AND AIR CONDITIONING. On Site Guide AK2-SC 255 REFRIGERATION AND AIR CONDITIONING On Site Guide AK2-SC 255 How to Use This Guide Read this Guide completely as you install and start up your new AK2-SC 255 controller. The guide will give you thorough

More information

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor 3 036 Room emperature Controller with 7-Day ime Switch, LCD and opt Remote emperature Sensor for heating systems RDE201 2-position control with ON/OFF output for heating Operating modes: normal operation

More information

USB-Link 2 Technical Guide. USB-Link 2 Code: SS0073 Version 4.11 and up

USB-Link 2 Technical Guide. USB-Link 2 Code: SS0073 Version 4.11 and up USB-Link 2 Technical Guide USB-Link 2 Code: SS0073 Version 4.11 and up TABLE OF CONTENTS GENERAL INFORMATION... 3 USB-Link 2 Overview... 3 System Requirements... 3 QUICK GUIDE...4 USB-LINK 2 DRIVER INSTALLATION

More information

Installation & Operation and Maintenance

Installation & Operation and Maintenance Gas Safety Products Dual Current Monitor Installation & Operation and Maintenance Read these instructions carefully before operating or servicing Rev: 01 Date: 12-02-18 1 CONTENTS Chapter Content Page

More information

Communication Register Map - Uniflair Cooling

Communication Register Map - Uniflair Cooling DIGITAL 0 1 1 - - - - DIGITAL 1 2 2 System On (Fan) 0 or 1 boolean R DIGITAL 2 3 3 Compressor 1 0 or 1 boolean R DIGITAL 3 4 4 Compressor 2 0 or 1 boolean R DIGITAL 4 5 5 Compressor 3 0 or 1 boolean R

More information

LOCAL DISPLAY UNIT (LDU)

LOCAL DISPLAY UNIT (LDU) LOCAL DISPLAY UNIT (LDU) The LDU200 is a LonWorks -based networked user interface panel used to display data and edit setpoint variables for vivariums, bio-containment, laboratory spaces, operating rooms,

More information

Networkable Dual Duct VAV Controller Specification and Installation Instructions

Networkable Dual Duct VAV Controller Specification and Installation Instructions Controller Models EVCBM14NIT2S (Master controller / 2 TRIACs) EVCS14N (Slave controller) TRL Series Thermostat TRL24 (Room Sensor: Temp) TRLH24 (Room Sensor: Temp and %RH) TRLG24 (Room Sensor: Temp and

More information

IntesisBox KNX - AIRZONE

IntesisBox KNX - AIRZONE IntesisBox KNX - AIRZONE Gateway for the integration of Airzone InnoBUS into KNX systems. Full integration of Airzone InnoBUS air conditioning with KNX control systems. CS CS KNX EIB Bus IntesisBox RS485

More information

DESCRIPTION OF MODBUS CONNECTION

DESCRIPTION OF MODBUS CONNECTION DESCRIPTION OF MODBUS CONNECTION MODBUS CONNECTION There is a possibility to control Air Handling Unit (AHU) from external management system (BMS), which work with MODBUS data processing. For MODBUS connection

More information

SEZ7656R1045B / SEZ7656H1045B

SEZ7656R1045B / SEZ7656H1045B SEZ7656R1045B / SEZ7656H1045B Installation Guide f BACnet MS-TP RTU / HP Room Controllers F Commercial Zoning Systems CONTENTS Installation 2 Location 2 Installation 2 BACnet System Overview 3 Terminal,

More information

TLR-D42 with OPA-D42 Intelligent PI fan coil controller for modulating actuators. Cabinet mounted base, wall mounted operation terminal.

TLR-D42 with OPA-D42 Intelligent PI fan coil controller for modulating actuators. Cabinet mounted base, wall mounted operation terminal. TLR-D42 with OPA-D42 Intelligent PI fan coil controller for modulating actuators. Cabinet mounted base, wall mounted operation terminal. Features Temperature control for 2-pipe and 4-pipe fan coil systems.

More information

SELENA. TEMPERATURE MONITORING AND CONTROL ( Option # 711, # 712 and # 713 ) Rev. 32

SELENA. TEMPERATURE MONITORING AND CONTROL ( Option # 711, # 712 and # 713 ) Rev. 32 SELENA TEMPERATURE MONITORING AND CONTROL ( Option # 711, # 712 and # 713 ) Rev. 32 In all temperature monitoring or control configurations the function Fn 61 must be enabled. The functions Fn 0 and Fn

More information

OP10. Pre-programmed, configurable controller for simple applications

OP10. Pre-programmed, configurable controller for simple applications revision 10 2013 OP10 Pre-programmed, configurable controller for simple applications The Optigo OP10 range of controllers can be set to handle everything from temperature or humidity control to control

More information

SCROLL GAS PRICE DISPLAY SYSTEM ROS SERIES INSTALLATION MANUAL REV 3.0

SCROLL GAS PRICE DISPLAY SYSTEM ROS SERIES INSTALLATION MANUAL REV 3.0 SCROLL GAS PRICE DISPLAY SYSTEM ROS SERIES INSTALLATION MANUAL REV 3.0 Fax: (514) 683-0068 Rev : 3.0 www.novyc.com Page 1 of 11 WARNING The ROS Scroll Display System must be installed as per Novyc International's

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control system for various gas, temperature and humidity detection, control and

More information

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use General and New Features The OS-6 is an industrial grade Ozone controller and monitor. The OS-6 design has been optimized for accuracy, ease

More information

RTD-W Installation Instructions

RTD-W Installation Instructions RTD-W Installation Instructions 0V +V POWER 15-24VDC 0V S1 S2 S3 0V S4 S5 S6 English RTD-W Installation Instructions 100.00 RTD-W Control Interface realtime Control Systems 24VAC/30VDC, 1A REMC P1 P2 RS485

More information

RTD-NET Installation Instructions

RTD-NET Installation Instructions LED3 SW1 LED4 RTD-NET Installation Instructions 0V +V POWER 15-24VDC English RTD-NET Installation Instructions 100.00 RTD-NET Control Interface realtime Control Systems REMC P1 P2 RS485 D-BUS DB DA GND

More information

Central Controller Operation & Installation Manual

Central Controller Operation & Installation Manual Central Controller Operation & Installation Manual YCZ-A004 CONTENT Function introduction of central controller... 1 Part info for central controller... 2 Page & Key Explanation... 4 Address Setting When

More information

Temperature controller Multi-zone ducted systems

Temperature controller Multi-zone ducted systems 2 727 emperature controller ulti-zone ducted systems ulti-zone model with up to six zone outputs RRV856 ultifunctional controller used for central control of ducted HVAC systems in combination with QAX850

More information

FX2-CHILLER. Digital Control. Operations Manual

FX2-CHILLER. Digital Control. Operations Manual FX2-CHILLER Digital Control Operations Manual Micro Air Corporation Phone (609) 259-2636 124 Route 526 www.microair.net Allentown NJ 08501 Fax (609) 259-6601 Introduction: The FX2-CHILLER digital control

More information

Communicative controller for VAV systems

Communicative controller for VAV systems FCR015 Communicative controller for VAV systems Summary FCR015 is a communicative controller for heating and cooling panels and a VAV (variable air volume) damper. It measures temperature and CO 2 concentration

More information

Dieter Wirth, Mess & Regeltechnik Neidlingen

Dieter Wirth, Mess & Regeltechnik Neidlingen Dieter Wirth, Mess & Regeltechnik Neidlingen Temperature controller Mod. BI50, BT31/32 and BI500, BT310/320/321 Made in Germany contents BT series 1. General Description... 2 2. Operating modes... 2 3.

More information

Modbus Header Temperature Sensor Kits: Standard Voltage Low Voltage

Modbus Header Temperature Sensor Kits: Standard Voltage Low Voltage Technical Instruction Document Modbus Header Temperature Kits: 24444-1 Standard Voltage 24444-3 Low Voltage Disclaimer The information contained in this manual is subject to change without notice from

More information

SERVICE MANUAL VMF-E5

SERVICE MANUAL VMF-E5 SERVICE MANUAL VMF-E5 FR SOFTWARE VERSION Ed. Date Author Notes Draft 25/02/2009 F. Carpanese First drawing-up 01/04/2009 F. Carpanese Introduction of the domestic hot water pages 19/06/09 F. Carpanese

More information

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). Vision OPLC Installation Guide Models 230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). General Description Vision OPLCs

More information

UPDATING CONTROLLERS USING PRISM 2 Updating the VCB-X / VCC-X Controller

UPDATING CONTROLLERS USING PRISM 2 Updating the VCB-X / VCC-X Controller Updating the VCB-X / VCC-X Controller Updating the VCB-X / VCC-X Controller Using Prism 2 Version 4.5.0 and higher The VCB-X and VCC-X Controllers are equipped with the ability to update their software

More information

Temperature controller Ducted systems

Temperature controller Ducted systems 2 725 Temperature controller Ducted systems Standard model without zoning functions RRV851 Multifunctional controller used for central control of ducted HVAC systems in combination with a QAX850 master

More information

CONTROLLER INSTALLATION OPERATION & QUICK START

CONTROLLER INSTALLATION OPERATION & QUICK START CONTROLLER INSTALLATION OPERATION & QUICK START Controller: 8403-066 ECU Series Controller Manual: 2100-559 Supersedes: NEW File: Tab 19 Date: 05-02-11 Page 1 of 6 TABLE OF CONTENTS Installation Note...

More information

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use General and New Features The OS-6 is an industrial grade Ozone controller and monitor. The OS-6 design has been optimized for accuracy, ease

More information

Quick Start Installation and User Manual

Quick Start Installation and User Manual 1 Quick Start Installation and User Manual Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation Settings

More information

Room Temperature Controller

Room Temperature Controller 3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:

More information

RDF Series Room Temperature Controllers

RDF Series Room Temperature Controllers Document No. 19-49 RDF Series Room Temperature Controllers Product Description Room Temperature Controllers with LCD for twopipe (with and without an electrical heater) and fourpipe fan coil units. Installation

More information

RS-WMB, RD-WMB Wallbus Room Sensors and Displays

RS-WMB, RD-WMB Wallbus Room Sensors and Displays Data Sheet Wallbus Room Sensors and Displays The RS-WMB and RD-WMB series of room sensors and displays are designed for mounting on a standard electrical back box. They include a temperature sensor with

More information

Expansion Module HZS 541-1S

Expansion Module HZS 541-1S Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 40804 Page of 7 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control

More information

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN Tracer Controls Tracer Unitary Controller 7 April 2003 BAS-PRC012-EN Introduction The Tracer unitary controller provides digital control that is similar to that of a wall thermostat. It supports the following

More information

Omni. User Manual. Economic Self-Tune PID Temperature Controller. Omni 96. Omni 72 72X72. Omni ~ 265 V AC SUPPLY

Omni. User Manual. Economic Self-Tune PID Temperature Controller. Omni 96. Omni 72 72X72. Omni ~ 265 V AC SUPPLY Omni Economic Self-Tune PID Temperature Controller Omni 7 Omni 4 6 5 4 3 1 7X7 7 1 11 5 ~ 65 V AC SUPPLY Omni 6 CONTENTS 1. PANEL MOUNTING & ELECTRICAL CONNECTIONS 1. FRONT PANEL : LAYOUT AND OPERATION

More information

ExactLogic BACnet Communicating Thermostat EXL01816 Sequence Datasheet

ExactLogic BACnet Communicating Thermostat EXL01816 Sequence Datasheet ExactLogic BACnet Communicating Thermostat EXL01816 Sequence Datasheet DataSheet ev 1.12.307/4.0 Jun 20, 2018 Operating Sequence Standard Occupied During normal occupied operation the display will show

More information

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual Manual NanoTron Dual Timer Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com email: support@advantagecontrols.com

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

pco: universal stage controller User guide Program code: EPSTDEIU0A Rif.: 96EM

pco: universal stage controller User guide Program code: EPSTDEIU0A Rif.: 96EM pco: universal stage controller User guide Program code: EPSTDEIU0A Rif.: 96EM TABLE OF CONTENTS 1 DETAILS OF THE PROGRAMME...3 2 USER INTERFACE...3 2.1 TERMINAL UNIT: FRONT PANEL VIEW WITH FRONT DOOR

More information

This Datasheet for the IC660BBA101. Block 115Vac/125Vdc RTD Input 6 Channels.

This Datasheet for the IC660BBA101. Block 115Vac/125Vdc RTD Input 6 Channels. This Datasheet for the IC660BBA101 Block 115Vac/125Vdc RTD Input 6 Channels http://www.qualitrol.com/shop/p-14423-ic660bba101.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

Instructions manual. Thermostat User Manual

Instructions manual. Thermostat User Manual Instructions manual Thermostat 02905 User Manual Table of Contents 1. Thermostat 02905 2 2. Inserting new / replacement batteries 2 3. Display 3 3.1 Functions of the buttons 4 3.2 Symbols 4 3.3 Ecometer

More information

IntesisBox PA-AW-MBS-1 v.2.0

IntesisBox PA-AW-MBS-1 v.2.0 IntesisBox PA-AW-MBS-1 v.2.0 Modbus RTU (EIA485) Interface for Panasonic Aquarea series. User Manual Issue Date: 08/2014 r2.0 Order Code: PA-AW-MBS-1: Modbus RTU Interface for Panasonic Aquarea series

More information

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION! TUC2 / TUCH2 Model Series Installation Instructions PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION! APPLICATION The TUC2 provides temperature space monitoring with a backlit LCD. The TUCH2 provides

More information

Carbon Monoxide (CO) Gas Detection and Control System

Carbon Monoxide (CO) Gas Detection and Control System Carbon Monoxide (CO) Gas Detection and Control System DESCRIPTION Gas monitor with built-in carbon monoxide (CO) sensor, wall-mounted, accepts inputs from remote devices such as other gas sensors, temperature

More information

Instruction Manual CTC-1

Instruction Manual CTC-1 Troubleshooting & Specs CTC-1 Amps / Volts requirements Min / Max operating temperature Min / Max operating Humidity Temperature Measurement range Temperature Accuracy CO2 sensor type CO2 Measurement range

More information

CONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE

CONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE Catalogue 207 CONTENTS CONTROLLERS... 4 room controllers... 5 room units... 29 control units... 24 PRODUAL 3 CATALOGUE T U R KU I C T C ON T R OL L E R S Multifunctional controllers for optimal performance

More information

ULTRASTAT23 Operating Instructions For the MEC-110 with ENHANCED SMS 10-Product Cooking Controller

ULTRASTAT23 Operating Instructions For the MEC-110 with ENHANCED SMS 10-Product Cooking Controller ULTRASTAT23 Operating Instructions For the MEC-110 with ENHANCED SMS 10-Product Cooking Controller THIS APPLIANCE IS FOR PROFESSIONAL USE AND IS TO BE USED ONLY BY QUALIFIED PERSONNEL 302 Spencer Lane

More information

quick start guide Carel EVD Evolution MODBUS Device E2 Setup for

quick start guide Carel EVD Evolution MODBUS Device E2 Setup for Carel EVD Evolution MODBUS Device E2 Setup for 527-0355 This document will guide you through setting up and commissioning the Carel EVD Evolution MODBUS device in the E2 controller. Note that Open MODBUS

More information

2-Axis Counter BDD 622

2-Axis Counter BDD 622 2-Axis Counter BDD 622 Technical Description, User's Guide english No. 622-221 D/E. Edition 0701; Subject to modification. www.balluff.com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.f. Germany

More information

DVFP Series Variable Frequency Drive - Product Manual. pg. 1

DVFP Series Variable Frequency Drive - Product Manual. pg. 1 pg. 1 Set Up Instructions for DVFP Inspect the packaging of the equipment to confirm that nothing was damaged during shipping. Remove the system from the packaging. Make sure everything is included and

More information

Manual FC 3500 DC Fan Control

Manual FC 3500 DC Fan Control Manual FC 3500 DC Fan Control Description: FC 3500 DC Type: Manual File: Do150304 FC 3500 DC V12 EN.docx VDH Products BV Pages: By: Initials: 23 BVDB Doc.no: Version: Date: 150304 1.2 15-04-2015 Table

More information

ExactLogic BACnet Communicating Zone Damper EXL01710 Sequence Datasheet

ExactLogic BACnet Communicating Zone Damper EXL01710 Sequence Datasheet ExactLogic BACnet Communicating Zone Damper EXL01710 Sequence Datasheet DataSheet ev 1.12.302/4.3 October 27, 2014 Operating Sequence Standard Occupied During normal occupied operation the display will

More information

Mercury T Controller Installation & User Guide

Mercury T Controller Installation & User Guide PR0700 Mercury - TM PR0701 Mercury - TE Mercury T Controller Installation & User Guide For Products: - PR0710, PR0711, PR0720, PR0721 Resource Data Management Ltd 80 Johnstone Avenue, Hillington Industrial

More information

2001VT Temp & CO 2. - air quality sensor/controller NOTE!!! Manual for Installation. General. SenseAir AB

2001VT Temp & CO 2. - air quality sensor/controller NOTE!!! Manual for Installation. General. SenseAir AB 2001VT Temp & CO 2 - air quality sensor/controller Manual for Installation SenseAir AB EM_2001VT _rev4/dec. -00 General The IAQ-sensor 2001 VentoThermostat is a carbon dioxide and temperature monitor and

More information

UPDATING CONTROLLERS USING PRISM 2 Updating the VCC-X Controller

UPDATING CONTROLLERS USING PRISM 2 Updating the VCC-X Controller Using Prism 2 7. Click on the icon. The Job-Sites Window will appear. In the Type of CommLink Dialog Box, select CommLink 5 or USB Link II. The VCC-X Controller is equipped with the ability

More information

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A pool/spa control system IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller User s and Installation Guide P/N 520886 - Rev A *520886* i MobileTouch Wireless Controller kit contents The

More information

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options. TUC03 Configurable Terminal Unit Controller Product Bulletin The TUC03 Configurable Terminal Unit Controller is designed specifically to provide direct digital control of terminal unit applications with

More information

SEZ7656E1045B. Installation Guide for BACnet MS/TP RTU Terminal with IAQ Control CONTENTS

SEZ7656E1045B. Installation Guide for BACnet MS/TP RTU Terminal with IAQ Control CONTENTS SEZ7656E1045B Installation Guide f BACnet MS/TP RTU Terminal with IAQ Control CONTENTS Installation 2 Location 2 Installation 2 BACnet System Overview 3 Terminal, Identification and Function 4 Wiring 4

More information

Semi flush-mounted room temperature controllers with LCD

Semi flush-mounted room temperature controllers with LCD s 3 077 RDD310 RDE410 Semi flush-mounted room temperature controllers with LCD For heating systems RDD310 RDE410 RDD310 and RDE410 features: Operating voltage AC 230 V 2-position control with On / Off

More information