1 Veritas Appliance Hardware Service Procedure I/O module replacement: Veritas 5240 Appliance Storage Shelf Document Number: 158 Version: 4.0 (7/04/16) Purpose This document describes the process for replacing an I/O module in a Veritas Storage Shelf for the NetBackup 5240 Appliance. Affected storage shelves NetBackup 5240 Storage Shelf The NetBackup 5240 Storage Shelf is a 2U12 drive enclosure that contains twelve 6TB 7200 rpm SAS hard disk drives, for a backup storage capacity of 49TBs. Each disk drive can be accessed from the storage shelf's front panel. An embedded RAID controller is used to configure the disk drives into a RAID 6 configuration. One of the disk drives is reserved as a hot spare. Figure 1 NetBackup 5240 Storage Shelf front view Figure 2 NetBackup 5240 Storage Shelf rear view 1
2 Onsite Policies and Procedures HSP #158 I/O module replacement: Veritas 5240 Appliance Storage Shelf Electrical safety The static discharged by human bodies can damage static-sensitive components on the boards. When installing and maintaining the equipment, observe appropriate electrostatic safety precautions to prevent personnel injuries or device damage. When operating a device in an electrostatic sensitive area, you must take electrostatic-discharge (ESD)-preventive measures. These include wearing ESD-preventive gloves, an ESD-preventive wrist strap, and ESD-preventive clothes to avoid personnel injury or device damage. To prevent damage to the device, pay attention to the following during operations: Do not touch devices with bare hands because ESD from the human body may damage the electrostatically sensitive elements on a board. When dealing with the server or any of the internal components, wear an ESD-preventive wrist strap, ESD-preventive gloves, and ESD-preventive suit. Hardware part replacement procedure This section describes how to remove and replace an I/O module in a Veritas 5240 Storage Shelf. Requirements Hot-swappable I/O module kit Cable labels Pen or pencil with which to write on the labels About the Veritas 5240 Storage Shelf I/O modules The rear panel of the Veritas 5240 Storage Shelf contains two I/O modules. These modules are located between the Power Cooling Modules (PCM). The two I/O modules slide into the rear of the shelf, with I/O module 0 above I/O module 1. The storage shelf can run with only one functioning I/O module. If both I/O modules are faulty the storage shelf must be turned off. The following figure shows the locations of the I/O modules and the locations of the status LEDs. I/O Module 0 I/O Module 1 2
3 When an I/O module fails, its amber Fault LED illuminates. Note that the I/O module's blue ID LED may also be illuminated. You must have access to the rear panel of the storage shelf. It is not necessary to remove the shelf from the rack. To remove the faulty I/O module 1 Locate and identify the storage shelf with the faulty module. 2 Verify that the storage shelf is the unit identified in the work order. If the work order provides the storage shelf serial number, verify that the work order serial number and the storage shelf serial number match. You can find the serial number by looking at the tab on the left Power Cooling Module. Serial Number starts with SH 3 Identify the failed I/O module by investigating the rear of the storage shelf. 4 Ensure the other I/O module is still working. 5 Locate the SAS3 cable or cables from the faulty I/O module. Label the cables with the port letter of the I/O module SAS3 ports from which you remove the cables. Write down on paper the location of the plastic blue tabs on the cable connectors. They either are on top of the cable connector or underneath it. You must ensure that the blue tabs on the replacement cables are oriented exactly as they were on the original faulty cable or cables. Note: The serial ports are not used. There should not be any cables attached to the serial port. 6 Remove the SAS3 cable or cables from the faulty I/O module. Do not disconnect the other ends of the cables from another storage shelf or from the appliance. 7 Locate the release latch at the bottom of the faulty I/O module. 8 With your thumb and forefinger, grasp the latch and gently squeeze it to release the latch of the module as displayed in the step 1 of the following figure. 3
4 9 Swing the latch out and use it as a handle to remove the I/O module as displayed in the step 2 in the following figure. 10 Gently pull on the latch to remove the I/O module from its housing. 11 Place the module in an ESD-preventive bag. To install the I/O module 1 Locate the replacement I/O module. 2 Remove the module from any packaging. 4
5 3 Slide the I/O module into the chassis. Make sure that the latch is swung out in the released position. 4 Begin closing the I/O module latch when you feel resistance as you slide the I/O module into the chassis. Closing the latch helps guide the I/O module into place. After you fully push the I/O module into the chassis, the latch snaps into place. 5 The latch snaps into place 6 Verify that the module is inserted all the way into the housing. 7 Wait up to 3 minutes for the LEDs to light up. 8 Replace the SAS3 cables into their correct ports. Make sure that the cable labels match the port labels. Also ensure that the blue tabs are positioned exactly as they were with the faulty SAS3 cable or cables. The blue tabs are either positioned on top of the cable connector or beneath it. Refer to your cable removal notes. Note: The I/O modules are installed as mirror images of each other. As a result, the latch of the I/O module 0 is located at the bottom of the I/O module. The latch of the I/O module 1 is located at the top of the I/O module. After completing the hardware replacement procedures, Veritas recommends that you do the following: Remove all boxes and shipping containers from the installation area. Recycle materials as much as possible. Return any equipment or tools as needed. 5
Veritas Appliance Hardware Service Procedure
Veritas Appliance Hardware Service Procedure Replacing a RAID Controller in a Veritas 5U84 Primary Storage Shelf Document Number: 217 Version: 1.0 (11/06/17) Purpose This document describes the process
More informationVeritas Appliance Hardware Service Procedure
Veritas Appliance Hardware Service Procedure Replacing a SAS3 cable in a Veritas storage shelf Document Number: 166 Version: 4.1 (03/05/18) Purpose This document describes the process of replacing the
More informationVeritas Appliance Hardware Service Procedure
Veritas Appliance Hardware Service Procedure Operating system disk drive and log disk drive replacement - NetBackup 0 Appliance Document Number: 7 Version:.0 (7/0/6) Purpose This document describes the
More informationVeritas Appliance Hardware Service Procedure
Veritas Appliance Hardware Service Procedure Replacing hard disk drives in a Primary Storage Shelf or an Expansion Storage Shelf Document Number: 137 Version: 3.2 (03/06/17) Purpose This document describes
More informationVeritas Appliance Hardware Service Procedure
Veritas Appliance Hardware Service Procedure Power Supply Replacement: NetBackup 5220 Appliance Document Number: 112 Version: 3.0 (10/03/15) Purpose This document describes the process for replacing a
More informationVeritas Appliance Hardware Service Procedure
Veritas Appliance Hardware Service Procedure Replacing a Disk Drive Carrier Document Number: 210 Version: 1.0 (11/06/17) Purpose This document describes the process for replacing a 4-TB/8-TB disk drive
More informationVeritas Appliance Hardware Service Procedure
Veritas Appliance Hardware Service Procedure Replacing a 10Gb Ethernet SFP Optic Module in Veritas appliances Document Number: 130 Version: 4.2 (03/06/17) Purpose This document describes the process for
More informationVeritas Appliance Hardware Service Procedure
Veritas Appliance Hardware Service Procedure Replacing a 16Gb Fibre Channel SFP optic module in Veritas appliances Document Number: 211 Version: 1.0 (11/06/17) Purpose This document describes the process
More informationReplacing a 3.5-inch disk drive
EMC VNXe Replacing a 3.5-inch disk drive 302-000-213 REV 02 July, 2015 This document describes how to replace a disk drive in a supported 12-slot disk enclosure: 12-slot disk processor enclosure (DPE)
More informationCustomer Replacement Procedure
Customer Replacement Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid Replacing a faulted 80-drive DAE cooling module 302-003-777 REV 01 July 2017 This document describes how to replace
More informationCustomer Upgrade Procedure
Customer Upgrade Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid Adding an optional 80-drive DAE disk drive 302-003-780 REV 01 July 2017 This document describes how to add an optional 80-drive
More informationDNS-2608 Enterprise JBOD Enclosure User Manual
DNS-2608 Enterprise JBOD Enclosure User Manual Nov.2017 Copyright DataON. All rights reserved. www.dataonstorage.com 1 Contents Package Contents... 3 System Requirements... 3 Technical Support... 3 DataON
More informationEMC VNXe. Replacing a link control card in a 12-slot disk-array enclosure REV 02. July, 2015
EMC VNXe Replacing a link control card in a 12-slot disk-array enclosure 302-000-216 REV 02 July, 2015 This document describes how to replace a link control card (LCC) in a 12-slot disk-array enclosure
More informationCustomer Replacement Procedure
Customer Replacement Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid Replacing a faulted 80-drive DAE system status card 302-003-774 REV 01 July 2017 This document describes how to replace
More informationEMC VNXe. Adding input/output modules to a disk processor enclosure REV 03. July, 2015
EMC VNXe Adding input/output modules to a disk processor enclosure 302-000-206 REV 03 July, 2015 This document describes how to add input/output (I/O) modules to a DPE (disk processor enclosure). The printed
More informationETERNUS JX60. Technical Product Introduction. 0 Copyright Fujitsu, Release June 2014
0 Copyright Fujitsu, Release June 2014 Highlights The passive storage subsystem accommodates up to 240 HDDs 3.5" SAS 2.0 Nearline SAS 7200 rpm, max. storage capacity 960 TB 1) One or two 6 Gbit/s SAS interfaces
More informationReplacing an Advanced Power and Cooling (APC) Unit
Replacing an Advanced Power and Cooling (APC) Unit You must replace a failed APC unit as quickly as possible (within minutes) to maintain correct airflow and cooling. Failed APC units can be hot-swapped.
More informationDell SC5020 and SC5020F Storage System Owner s Manual
Dell SC5020 and SC5020F Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates
More informationCustomer Replacement Procedure
Customer Replacement Procedure Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid Replacing a faulted 25-drive link control card 302-002-600 REV 02 July 2017 This document describes how to
More informationCustomer Replacement Procedure
Customer Replacement EMC Unity Family EMC Unity Hybrid Replacing a faulted 3.5-inch disk drive 302-002-595 REV 01 May, 2016 This document describes how to replace a faulted 3.5-inch disk drive in the Unity
More informationInstalling the Cisco ADE 2130 and 2140 Series Appliance Hardware Options
CHAPTER 4 Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options This chapter provides instructions for installing, replacing, and removing various hardware options in your Cisco ADE
More informationSAS Disk Shelves. Service Guide. For DS460C, DS224C and DS212C. November _C0
SAS Disk Shelves Service Guide For DS460C, DS224C and DS212C November 2018 215-11810_C0 doccomments@netapp.com Table of Contents 3 Contents Hot-swapping a disk drive in a DS224C or DS212C disk shelf...
More informationSerial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E
Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Order Number:
More informationSCv3000 and SCv3020 Storage System. Owner s Manual
SCv3000 and SCv3020 Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates
More informationCustomer Replacement Procedure
Customer Replacement EMC Unity Family EMC Unity All Flash and EMC Unity Hybrid Replacing a faulted 2.5-inch disk drive 302-002-594 REV 01 May, 2016 This document describes how to replace a faulted 2.5-inch
More informationCustomer Replacement Procedure
Customer Replacement Procedure Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid Replacing a faulted 25-drive DAE power supply and cooling module 302-002-598 REV 02 September 2017 This document
More informationDell SCv300 and SCv320 Expansion Enclosure Owner's Manual
Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Regulatory Model: E03J, E04J Regulatory Type: E03J001, E04J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that
More informationPC9/P9 Floppy Drive Replacement
Introduction These instructions explain how to replace the floppy disk drive in the PC9 Industrial PC or the P9 PowerStation. They include steps for disassembling the unit, removing the previously installed
More informationCustomer Upgrade Procedure
Customer Upgrade EMC Unity Family EMC Unity All Flash and EMC Unity Hybrid Adding an optional 2.5-inch disk drive 302-002-592 REV 01 May, 2016 This document describes how to add an optional 2.5-inch disk
More informationapple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.
apple Service Source Xserve RAID 17 March 2003 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc. All rights reserved. Overview Xserve RAID
More informationCustomer Replacement Procedure
Customer Replacement EMC Unity Family EMC Unity All Flash and EMC Unity Hybrid Replacing a faulted cooling module 302-002-591 REV 01 May, 2016 This document describes how to replace a faulted cooling module
More informationDell EMC Storage MD1280 Enclosure Owner's Manual
Dell EMC Storage MD1280 Enclosure Owner's Manual Regulatory Model: SP-2584, E11J Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product.
More informationTable of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...
Table of Contents Quick Install Guide page 1 EN English Table of Contents 1. Introduction... 2 1.1 Safety... 2 1.2 Rack System Precautions... 2-3 1.3 ESD Precautions... 3... 3 1... 3 2 Fitting PSU s...
More informationEMC CloudArray. Customer Maintenance Guide REVISION 6.0
EMC CloudArray Customer Maintenance Guide REVISION 6.0 Copyright 2015-2016 EMC Corporation. All rights reserved. Published in the USA. Published March, 2016 EMC believes the information in this publication
More informationInstallation Instructions
Installation Instructions Cat. No. 1771-OND Series B This document provides information on: important pre-installation considerations power supply requirements installing the module setting the fault mode
More informationInstallation Instructions
Installation Instructions This document provides information on: important pre-installation considerations power supply requirements initial handling installing the module using the indicators for troubleshooting
More informationPC9/P9 CPU Card Replacement
Introduction These instructions explain how to replace the CPU card in the PC9 Industrial PC or the P9 PowerStation. They include steps for disassembling the unit, removing the old CPU card, installing
More informationInstalling the Cisco SFS 3504 Server Switch
CHAPTER 3 This chapter describes how to mount your Cisco SFS 3504 Server Switch on a rack, boot the Cisco SFS 3504 Server Switch, and configure basic services. For advanced configuration information, see
More information3 Here is a short overview of the specifications. A link to a data sheet with full specification details is given later in this web based training
1 Welcome to this web based training session. This presentation provides you an introduction to the Fujitsu ETERNUS JX40. The JX40 is a passive direct server attached drive extension offering extension
More informationReplacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x
Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x Last Updated: December 4, 2014 Use these instructions to replace the RAID battery backup unit (BBU)
More informationapple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.
apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May 2004 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc.
More informationInstallation Instructions
Installation Instructions This document provides information on: important pre-installation considerations power supply requirements initial handling procedures installing the module using the indicators
More informationInstalling a Network Module
3 CHAPTER This chapter describes how to install and connect a network module. Overview, page 3-1 in the Switch, page 3-4 SFP and SFP+ Modules, page 3-7 Finding the Network Module Serial Number, page 3-9
More information2002 Series FRU Installation and Replacement Guide
2002 Series FRU Installation and Replacement Guide P/N 83-00004523-11 Revision C August 2009 Copyright Protected Material 2009. All rights reserved. R/Evolution and the R/Evolution logo are trademarks
More informationIntel Server Board S2600BP Intel Compute Module HNS2600BP Product Family
Intel Server Board S2600BP Intel Compute Module HNS2600BP Product Family Quick Start Guide for Node Replacement A document providing instruction for the replacement of Intel Compute Modules using an Intel
More informationTo connect the AC adapter:
Replacing the AC Adapter Replacing the AC Adapter 3 Plug the power cord into a wall outlet. The power indicator turns on. To connect the AC adapter: Connect the power cord to the AC adapter. Power indicator
More informationMaintaining the ERX System
7 This chapter describes the procedures that you must perform to maintain the ERX system and its components. Other maintenance procedures must be performed by an authorized Juniper Networks technician.
More informationInstallation Instructions
Installation Instructions This document provides information on: important pre-installation considerations power supply requirements initial handling procedures installing the module using the indicators
More informationInstallation Instructions
Installation Instructions This document provides information on: important pre-installation considerations power supply requirements initial handling installing the module short circuit protection using
More informationMaintaining E-Series Routers
Maintaining E-Series Routers 9 This chapter lists the tools, items, and steps needed for installing and uninstalling E-series components. Other maintenance procedures must be performed by an authorized
More informationDell SC7020 and SC7020F Storage Systems Owner s Manual
Dell SC7020 and SC7020F Storage Systems Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates
More informationDell SCv3000 and SCv3020 Storage System Owner s Manual
Dell SCv3000 and SCv3020 Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates
More informationReplacing the Gateway M305 Optical Drive
Replacing the Gateway M305 Optical Drive This package includes an optical drive, such as a CD or DVD drive, for your Gateway M305 notebook and these printed instructions. Installing a replacement drive
More informationMaintaining the ERX System
Maintaining the ERX System 7 This chapter describes the procedures that you must complete to maintain the ERX system and its components. Other maintenance procedures must be performed by an authorized
More informationPort Type Link Status (Left Side LED) Speed (Right Side LED) Green solid: Link detected/no activity Off: No link/card offline
C-Series FlexMedia Card: 36 Ports 10/100/1000 Base-T Ethernet (PoE and non-poe), 8 Ports 1G, 2 Ports 10G Feature Highlights and Installation Instructions Feature Highlights There are two versions of the
More informationInstallation Data. The 1771 OB module can control the following output devices: dc motor starters indicators solenoids
Installation Data This document provides information on: important pre installation considerations power supply requirements initial handling procedures installing the module using the indicators for troubleshooting
More informationRemoving Components from the MX480 Chassis Before Installing It Without a Lift
Removing Components from the MX480 Chassis Before Installing It Without a Lift If you cannot use a mechanical lift to install the router (the preferred method), you can install it manually. To make the
More informationP1 PowerStation Backlight Bulb
The P1 PowerStation is designed to allow you to easily replace the backlight bulb without removing the unit from its enclosure. However, CTC recommends that you remove the touch screen completely before
More informationRelease Notes. Electrostatic Discharge and Grounding Guide for Cisco NCS 2000 Series. Prerequisites. Preparing Your Location
First Published: 2017-01-31 Text Part Number: Electrostatic Discharge and Grounding Guide for Cisco NCS 2000 Series Prerequisites This document uses illustrations to explain the workflow that we recommend
More informationInstalling and Replacing Hardware Options
CHAPTER 4 This chapter provides instructions for installing and replacing the hardware components and field replaceable units (FRUs) in your Cisco NAM 2220 appliance. These instructions are intended for
More informationMODULUS 21 Power Distribution Unit (PDU) Replacement. Overview A. Introduction
Page 1 of 16 MODULUS 21 Power Distribution Unit (PDU) Replacement Overview Introduction This notice explains how to replace the AC Power Distribution Unit (PDU), also known as a Power Distribution Assembly
More informationInstalling a Network Module
Network Module Overview, page in the Switch, page 7 Removing a Network Module, page 3 SFP and SFP+ Modules, page 4 Finding the Network Module Serial Number, page 6 Network Module Overview Network Module
More informationDell Storage Center. Owner's Manual. SC180 Expansion Enclosure. Regulatory Model: E11J Regulatory Type: E11J001
Dell Storage Center SC180 Expansion Enclosure Owner's Manual Regulatory Model: E11J Regulatory Type: E11J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make
More informationInstallation Instructions
Installation Instructions This document provides information on: important pre-installation considerations power supply requirements initial handling installing the module using the indicators for troubleshooting
More informationInstallation Instructions
Installation Instructions This document provides information on: important pre-installation considerations power supply requirements initial handling procedures installing the module using the module indicators
More information256 Kbytes (1771-DRS) 1 Mbyte (1771-DRS1) 4 Mbytes (1771-DRS4) Installation Data
Installation Data You can add static RAM memory to your control coprocessor main module to expand user memory. The RAM single inline memory module (SIMM) is available in the following sizes: 256 Kbytes
More informationJDM Installation Guide
JDM Installation Guide Part 1: how to install the JetDrive SSD Upgrade Kit into your Mac - OS X 10.10 or earlier - OS X 10.11 (El Capitan) - OS X 10.13 (High Sierra) Part 2: how to install the JetDrive
More informationInstalling a Network Module
Network Modules Overview, page 1 in the Switch, page 2 Removing a Network Module, page 10 SFP and SFP+ Modules, page 11 Finding the Network Module Serial Number, page 13 Network Modules Overview The Cisco
More informationAllen-Bradley. User Manual. PLC-5 Backup Communication Module (1785-BCM, 1785-BEM) product icon
Allen-Bradley PLC-5 Backup Communication Module User Manual (1785-BCM, 1785-BEM) product icon Important User Information Because of the variety of uses for this product and because of the differences between
More informationEPX Touchscreen and Display Replacement Assemblies
EPX Touchscreen and Display Replacement Assemblies This document describes the procedures required to replace the touchscreen and display assembly in the EPX BZK-08T7 kit. The following procedures are
More informationFlexPower Server User Guide
FlexPower Server User Guide Disclaimer The source code contained or described herein and all documents related to the source code (Material) are owned by Intel Corporation or its suppliers or licensors.
More informationNvidia Quadro FX 5600 graphics card and auxiliary power adapter cable installation
Nvidia Quadro FX 5600 graphics card and auxiliary power adapter cable installation HP xw8600 and xw9400 Workstations This document describes how to install an Nvidia Quadro FX 5600 graphics card and an
More informationNetBackup 5220 and Symantec Storage Shelf
NetBackup 5220 and Symantec Storage Shelf Hardware Installation Guide Release 2.0 NetBackup 5220 and Symantec Storage Shelf : Hardware Installation Guide The software described in this book is furnished
More informationReplacing the Gateway M275 Keyboard
Replacing the Gateway M275 Keyboard This package includes a replacement keyboard for your Gateway M275 notebook and these printed instructions. Tools you need You need a small Phillips screwdriver and
More informationInstalling the EN-4000
EN-4000 Reference Manual Document 2 Installing the EN-4000 T his document discusses installation of the EN-4000 hardware. Note: The EN-4000 Quick Installation Guide is also available. 2.1 Collecting the
More informationRemoving Components from the MX960 Chassis Before Installing It Without a Lift
Removing Components from the MX6 Chassis Before Installing It Without a Lift If you cannot use a mechanical lift to install the router (the preferred method), you can install it manually. Before installing
More informationEMC Avamar Data Store Gen4S
EMC Avamar Data Store Gen4S Customer Service Guide 300-999-650 REV 04 Copyright 2012-2016 EMC Corporation. All rights reserved. Published in the USA. Published May, 2016 EMC believes the information in
More informationTiger Box Expansion Chassis Assembly Guide
Tiger Box Expansion Chassis Assembly Guide Product Overview................................. 3 Tiger Box Expansion Chassis Features............... 3 Package Content............................. 4 Hardware
More informationNetBackup 5000 Release Routine Maintenance. Issue 01. Date Symantec Corporation
NetBackup 5000 Release 6.6.0.2 Issue 01 Date 2010-03-26 Symantec Corporation Symantec provides customers with comprehensive technical support and service. For any assistance, please contact our local office
More informationRemoving and Replacing Chassis Components
This chapter provides instructions on how to remove and replace components from the Cisco NCS 4016 chassis., on page 1 Removing a Line Card This section describes how to remove a line card from the Cisco
More informationIntel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide
Intel NUC Kit DN2820FYKH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers and with the safety
More information1 Getting Started Installing & Configuring
Before you begin Installation and Setup Instructions for E-Series 60-Drive Trays E760 and E5660 controller-drive trays DE6600 expansion drive trays Unpack & Prepare Install Hardware Connect Drive Trays
More informationMemory (RAM) Replacement Instructions. apple PowerBook (FireWire) Tools Required. Electrostatic Discharge (ESD)
apple PowerBook (FireWire) Memory (RAM) Replacement Instructions Be sure to follow these instructions carefully. Failure to follow these instructions could result in damage to your equipment and may void
More informationIntel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide
Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers
More informationMaintaining the Avaya S8800 Server for Avaya Aura SIP Enablement Services
Maintaining the Avaya S8800 Server for Avaya Aura SIP Enablement Services 03-603448 Issue 1 November 2009 2011 Avaya Inc. All Rights Reserved. is 1-800-242-2121 in the United States. For additional support
More informationReadyNAS Rack-Mount Storage Systems
ReadyNAS Rack-Mount Storage Systems Hardware Manual Models: 1500 2100 3100 3200 4200 350 East Plumeria Drive San Jose, CA 95134 USA May 2011 202-10848-01 2011 NETGEAR, Inc. All rights reserved. No part
More informationLightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide
Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide 1800 19th Street / Bakersfield, CA 93301 / Tel: 661.716.7600 / Toll Free: 877.447.6244 / www.lightspeedsystems.com Table of Contents
More informationIntel NUC Kit NUC5i3MYHE & NUC5i5MYHE User Guide. Intel NUC Kit NUC5i3MYHE Intel NUC Kit NUC5i5MYHE User Guide
Intel NUC Kit NUC5i3MYHE Intel NUC Kit NUC5i5MYHE User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers
More informationBefore you begin. Installation and Setup Instructions for E-Series 60-Drive Trays. Unpack & Prepare. Install Hardware. Connect Hardware.
Before you begin Installation and Setup Instructions for E-Series 60-Drive Trays E760, E5560, and E5660 controller-drive trays DE6600 expansion drive trays Unpack & Prepare Install Hardware Connect Hardware
More informationSATA II HDD Canister KISS DA 435 Quick Reference Guide
SATA II HDD Canister KISS DA 435 Quick Reference Guide If it s embedded, it s Kontron 1. Table of Contents SATA II HDD Canister KISS DA 435 1. Table of Contents 1. Table of Contents... 1 2. Important Information...
More informationQuantum DXi4700 Capacity Upgrade Guide
Quantum DXi4700 Capacity Upgrade Guide This document contains the following topics: Introduction 2 Preparing for the Capacity Upgrade 6 Capacity Upgrade Overview 7 Determining the DXi4700 Model 9 Unpacking
More informationReplacing the Gateway M405 Keyboard
Replacing the Gateway M405 Keyboard This package includes a replacement keyboard for your Gateway M405 notebook and these printed instructions. Tools you need You need a small Phillips and a small flat-blade
More informationIntel NUC Kit DC53427HYE User Guide. Intel NUC Kit DC53427HYE
Intel NUC Kit DC53427HYE User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers and with the safety
More informationDell PowerVault MD3060e Storage Enclosure Owner's Manual
Dell PowerVault MD3060e Storage Enclosure Owner's Manual Regulatory Model: E08J Series Regulatory Type: E08J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you
More informationXTM 1050 Replacement Parts Installation
XTM 1050 Replacement Parts Installation Instructions to replace or install: Power Supply Chassis Fan Fiber Card 10 Gb Interface Module WARNING! Do not open the XTM 1050 or try to replace or install any
More informationAB Spares. Installation Data
Installation Data This document provides information on: important pre installation considerations power supply requirements initial handling procedures installing the module using the indicators for troubleshooting
More informationDell EMC PowerVault MD3460 Storage Arrays
Dell EMC PowerVault MD3460 Storage Arrays Owner's Manual Regulatory Model: E08J Series Regulatory Type: E08J001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you
More informationNetBackup Appliance Safety and Maintenance Guide
NetBackup Appliance Safety and Maintenance Guide Release 2.7.2 NetBackup 52xx and 5330 NetBackup Appliance Safety and Maintenance Guide Documentation version: 2.7.2 Legal Notice Copyright 2016 Veritas
More information742S 742i SC742 CHASSIS USER'S GUIDE
742S 742i SC742 CHASSIS USER'S GUIDE 1.0a SC742 Chassis User s Guide The information in this User s Guide has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility
More informationReplacing/Upgrading Mac Pro Processors (Early 2008)
Replacing/Upgrading Mac Pro Processors (Early 2008) The steps in this procedure illustrate how to remove the lower processor (CPU B). The instructions are the same for removing the upper processor (CPU
More information