CP 502. Piezoelectric pressure transducer. IECEx. » From the Vibro-Meter product line» Operating temperature range: 70 to 560 C ( 94 to F)

Size: px
Start display at page:

Download "CP 502. Piezoelectric pressure transducer. IECEx. » From the Vibro-Meter product line» Operating temperature range: 70 to 560 C ( 94 to F)"

Transcription

1 Piezoelectric pressure transducer FEATURES» From the Vibro-Meter product line» Operating temperature range: 70 to 560 C ( 94 to F)» Pressure capability: up to 100 bar (1450 psi)» Pressure sensitivity: 90 pc / bar (6.2 pc / psi)» Frequency range: 0.5 Hz to 20 khz» Certified for use in potentially explosive atmospheres IECEx APPLICATIONS» Pressure pulsation monitoring in turbines DESCRIPTION The piezoelectric pressure transducer uses industrially grown single-crystal GaPO 4 (gallium phosphate) as the piezoelectric. This special material exhibits outstanding thermal behaviour with no pyroelectricity, thereby guaranteeing excellent signal quality and virtually constant sensitivity over the lifetime of the device. In addition, the transducer has a very low response threshold and uses internal case insulation. Combined, these features make the an extremely stable and reliable device that is suitable for the longterm monitoring of pressure pulsations in turbines. The transducer is fitted with an integral mineral insulated cable (twin conductors) that can be terminated with either a LEMO connector or a high-temperature connector developed by Vibro-Meter. Cable assemblies are available to connect the transducer to an IPC 704 signal conditioner. Information contained in this document may be subject to Export Control Regulations of the European Union, USA or other countries. Each recipient of this document is responsible for ensuring that transfer or use of any information contained in this document complies with all relevant Export Control Regulations. ECN N/A. Meggitt SA / / Version 2 / / E 1 / 7

2 DESCRIPTION (continued) The IPC 704 signal conditioner can convert the charge-based signal from the pressure transducer into a current or a voltage signal. Using a current modulated output allows transmission over longer distances, for example, up to 1 km when a GSI galvanic separation unit is used. Combining an IPC 704 signal conditioner with the pressure transducer produces a dynamic pressure measurement system that outputs a voltage or current signal that is proportional to the measured pressure. In this pressure measurement system, each component is interchangeable. The piezoelectric pressure transducer is designed to measure dynamic pressure levels and is particularly suitable for measuring pulsation pressures in the combustors of modern gas turbines. For specific applications, contact your nearest Meggitt Sensing Systems representative. SPECIFICATIONS General Input power requirements Signal transmission Signal processing : None : Charge output, 2-pole system, insulated from casing : Charge converter Operating (at +23 C ±5 C or F ±9 F) Sensitivity (minimum, at 2 Hz) Dynamic measuring range (random) Overload capacity (spikes) Linearity : 90 pc / bar (6.2 pc / psi) : to 50 bar (0.005 to 725 psi) : Up to 100 bar (1450 psi) (static + dynamic components) : 1% over the dynamic measuring range Acceleration sensitivity Axial : 2 mbar / g ( 0.03 psi / g) Radial : 0.25 mbar / g ( psi / g) Frequency response : 2 to Hz ± 5%. The lower cut-off frequency is determined by the electronics used. For example, the IPC 704 signal conditioner has configurable high-pass and low-pass filters. Resonant frequency : > 50 khz (along sensitive axis) Capacitance (nominal) Transducer : 30 pf pole / pole Cable : 270 pf / m pole / pole; 210 pf / m pole / ground Internal insulation resistance : > Ω at 25 C (77 F), > 10 6 Ω at 560 C (1040 F) Environmental Corrosion, humidity Operating temperature range Transducer Vibro-Meter high-temperature connector LEMO connector : NIMONIC alloy 90, hermetically welded : 70 to +560 C ( 94 to F) : 70 to +650 C ( 94 to F) : 55 to +155 C ( 67 to +311 F) 2 / 7 Meggitt SA / / Version 2 / / E

3 SPECIFICATIONS (continued) Explosive atmospheres Available in Ex approved versions for use in hazardous locations Type of protection Ex i: intrinsic safety Europe EC type examination certificate LCIE 10 ATEX 3039 X II 1G (Zones 0, 1, 2) Ex ia IIC T6 to T570 North America ccsaus certificate * ccsaus Class I, Div. 1, Groups A, B, C, D Ex /AEx ia IIC International IECEx certificate of conformity * LCI X Ex ia IIC T6 to T570 * No marking Type of protection Ex na: type of protection n (non sparking) Europe Voluntary type examination certificate LCIE 10 ATEX 1001 X II 3G (Zone 2) Ex na II T6 to T570 For specific parameters of the mode of protection concerned and special conditions for safe use, please refer to the certificates that are available from Meggitt SA on demand. Calibration ISO 9001 certified calibration at +20 C (+68 F) with dead weight tester (3, 6, 8, 10, 12, 30, 50 bar). Sensitivity and linearity are determined according to DIN Typical response curve 10 Sensitivity deviation (%) Temperature ( C) Note: Reference at +20 C (+68 F). Mechanical Connection type Mounting Fastening torque (to combustion chamber) : 2-pole hard line cable (Ø 3.2 mm), insulated from casing, with either a LEMO connector or a Vibro-Meter high-temperature connector : See the mounting adaptors in Accessories and refer to the CP xxx piezoelectric pressure transducers manual : 50 N m (443 inch-pounds) nominal. 60 N m (531 inch-pounds) maximum. Meggitt SA / / Version 2 / / E 3 / 7

4 MECHANICAL DRAWINGS with LEMO connector 38.8 ±2 Length: See Ordering information 36 ±2 Ø ± Ø ± ± ±0.5 M8 x 0.75 Tolerance: ±1% or ±100 mm (whichever is greater) Ø 3.2 ±0.2 Ø 9 ±0.5 Ø 8.9 ±0.1 MARKING Twin core MI-cable 2-pole LEMO connector type PCA.0S.302.CLLN32. Recommended mating connector LEMO type 0 for low noise cable Ø 4.2 mm, screen connected. + with Vibro-Meter high-temperature connector Ø ± Ø ±2 9 ± ± ±0.5 M8 x 0.75 Length: See Ordering information Tolerance: ±1% or ±100 mm (whichever is greater) Ø 3.2 ± ± ±1 7 / UNS-2A Ø 8.9 ±0.1 MARKING Twin core MI-cable 2-pole high-temperature connector PNR XX HEX. 7 / / 7 Meggitt SA / / Version 2 / / E

5 ORDERING INFORMATION To order please specify: Type Designation Cable length Ordering number Piezoelectric pressure transducer with LEMO connector 1 m m m m Piezoelectric pressure transducer with Vibro-Meter high-temperature connector 1 m m m m ACCESSORIES MA 104 mounting adaptor for with LEMO connector HEX. (Torque: 20 N m 2 ) M12 x A Ø 11 H9 ( ) A Nom to to to 23.5 Ra 0.8 MA internal pressure seal (PNR ) R 0.1 max Ø 9.5 H9 ( ) Ordering information Type Designation Ordering number MA 104 Mounting adaptor Note: The MA 104 mounting adaptor does not include the MA seal below. MA seal MA internal pressure seal Meggitt SA / / Version 2 / / E 5 / 7

6 ACCESSORIES (continued) MA 126 mounting adaptor for with Vibro-Meter high-temperature connector MA internal pressure seal (PNR ) 13.5 ±0.1 (41) MA external pressure seal (PNR ) 2 ±0.05 Ø 23 ±0.1 Ø M18 x 1.5 HEX. 16 Torque: 20 N m +10 / 2 HEX. 20 Torque: 60 N m +25 / 5 Ordering information Type Designation Ordering number MA 126 Mounting adaptor Note: The MA 126 mounting adaptor includes the MA seals below. MA seal MA internal pressure seal MA seal MA external pressure seal Cable assemblies EC 153 Refer to the data sheet EC 222 Refer to the data sheet EC 119 Refer to the data sheet Signal conditioner IPC 704 Refer to the data sheet Galvanic separation GSI 12x Refer to the data sheet 6 / 7 Meggitt SA / / Version 2 / / E

7 Headquartered in the UK, Meggitt PLC is a global engineering group specializing in extreme environment components and smart sub-systems for aerospace, defence and energy markets. Meggitt Sensing Systems is the operating division of Meggitt specializing in sensing and monitoring systems, which has operated through its antecedents since 1927 under the names of ECET, Endevco, Ferroperm Piezoceramics, Lodge Ignition, Sensorex, Vibro-Meter and Wilcoxon Research. Today, these operations are integrated under one strategic business unit called Meggitt Sensing Systems, headquartered in Switzerland and providing complete systems, using these renowned brands, from a single supply base. The Meggitt Sensing Systems facility in Fribourg, Switzerland was formerly known as Vibro-Meter SA, but is now Meggitt SA. This site produces a wide range of vibration and dynamic pressure sensors capable of operation in extreme environments, leading-edge microwave sensors, electronics monitoring systems and innovative software for aerospace and land-based turbo-machinery. All statements, technical information, drawings, performance rates and descriptions in this document, whilst stated in good faith, are issued for the sole purpose of giving an approximate indication of the products described in them, and are not binding on Meggitt SA unless expressly agreed in writing. Before acquiring this product, you must evaluate it and determine if it is suitable for your intended application. Unless otherwise expressly agreed in writing with Meggitt SA, you assume all risks and liability associated with its use. Any recommendations and advice given without charge, whilst given in good faith, are not binding on Meggitt SA. Meggitt Sensing Systems takes no responsibility for any statements related to the product which are not contained in a current Meggitt Sensing Systems publication, nor for any statements contained in extracts, summaries, translations or any other documents not authored by Meggitt Sensing Systems. We reserve the right to alter any part of this publication without prior notice. In this publication, a dot (.) is used as the decimal separator and thousands are separated by thin spaces. Example: Sales offices Your local agent Head office Meggitt Sensing Systems has offices in more than 30 countries. For a complete list, please visit our website. ABCD ABCD Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Tel: Fax: Meggitt SA / / Version 2 / / E 7 / 7

PA 152. Probe mounting adaptor (high temperature)

PA 152. Probe mounting adaptor (high temperature) (high temperature) FEATURES» From the Vibro-Meter product line» For the external mounting of TQ proximity probes» Removable housing, with U-shaped retainer, that allows easier probe installation and gap

More information

IP 172. Interconnection protection mounting kit. » From the Vibro-Meter product line» Suitable for all TQ 4xx proximity measuring systems

IP 172. Interconnection protection mounting kit. » From the Vibro-Meter product line» Suitable for all TQ 4xx proximity measuring systems Interconnection protection mounting kit FEATURES» From the Vibro-Meter product line» Suitable for all TQ 4xx proximity measuring systems» Fits coaxial cables from Ø 2.6 to Ø 3.6 mm using miniature coaxial

More information

IOC4T. Input / output card. » From the Vibro-Meter product line» Signal interface card with 6 channels, for the MPC4 machinery protection card

IOC4T. Input / output card. » From the Vibro-Meter product line» Signal interface card with 6 channels, for the MPC4 machinery protection card FEATURES» From the Vibro-Meter product line» Signal interface card with 6 channels, for the MPC4 machinery protection card» Screw terminal strip (48 terminals) for all input / output connections» Contains

More information

Modular CPU card and input / output card

Modular CPU card and input / output card Modular CPU card and input / output card FEATURES» From the Vibro-Meter product line» One-Shot configuration of all VM600 cards using a direct Ethernet or RS-232 serial connection from an external computer,

More information

IECEx VSN010. VibroSmart DMS real-time Ethernet switch. » VibroSight compatible hardware from the. » Designed for operation with the VibroSmart

IECEx VSN010. VibroSmart DMS real-time Ethernet switch. » VibroSight compatible hardware from the. » Designed for operation with the VibroSmart VibroSmart DMS real-time Ethernet switch FEATURES» VibroSight compatible hardware from the Vibro-Meter product line» Designed for operation with the VibroSmart distributed monitoring system (DMS)» Real-time

More information

VM600 system segregation and cyber security

VM600 system segregation and cyber security Application note 021 VM600 system segregation and cyber security. VM600 rack-based systems have always been secure by design. Since its beginning, the VM600 system was conceived and designed to separate

More information

VM600 modular CPU card and input /output card

VM600 modular CPU card and input /output card VM600 modular CPU card and input /output card FEATURES» From the Vibro-Meter product line» One-Shot configuration of VM600 cards using a direct Ethernet or RS-232 serial connection from an external computer,

More information

AMC8 and IOC8T Analog monitoring card and input / output card

AMC8 and IOC8T Analog monitoring card and input / output card Analog monitoring card and input / output card FEATURES AMC8» From the Vibro-Meter product line» Two cards providing 8 channels of temperature and process monitoring for VM600 systems» 8 channels of software

More information

VibroSmart DMS VSI010

VibroSmart DMS VSI010 VibroSmart DMS communications interface module FEATURES» VibroSight compatible hardware from the Vibro-Meter product line» Communications interfaces for industry standard fieldbuses: Modbus RTU, Profibus

More information

Proximity Transducers, Seismic Sensors and Accessories

Proximity Transducers, Seismic Sensors and Accessories 8mm, 5mm Proximity Probe TM0180 and TM0105 Systems Introduction to proximity probe transducers Proximity probe transducers are used to measure the static and dynamic distance between the target and the

More information

Meggitt Sensing Systems

Meggitt Sensing Systems VibroSmart distributed monitoring system Meggitt Sensing Systems VibroSmart distributed monitoring for industrial turbines, critical machinery and balance-of-plant equipment enables you to monitor more

More information

8mm, 5mm Proximity Probe TM0180 and TM0105 Systems

8mm, 5mm Proximity Probe TM0180 and TM0105 Systems 8mm, 5mm Proximity Probe TM0180 and TM0105 Systems Introduction to proximity probe transducers Proximity probe transducers are used to measure the static and dynamic distance between the target and the

More information

VibroSight portable analyser VSPA. » From the Vibro-Meter product line» Portable condition monitoring system (CMS)

VibroSight portable analyser VSPA. » From the Vibro-Meter product line» Portable condition monitoring system (CMS) portable analyser VSPA FEATURES» From the Vibro-Meter product line» Portable condition monitoring system (CMS) based on proven VM600 system technology» Lightweight self-contained system with a rugged metal

More information

Proximity Transducers, Seismic Sensors and Accessories

Proximity Transducers, Seismic Sensors and Accessories PVTVM s Proximity Selection Guide Part Number (Initial Prefix) TM0105 TM0180 TM0110 TM0120 Tip Size 5mm 8mm 11mm 25mm Model Type Standard, Standard, Standard, 7200 compatible 7200 compatible 7200 compatible

More information

VM600 Configuration Software. Configuration Software for VM600 Series Machinery Protection Systems (MPS) FEATURES

VM600 Configuration Software. Configuration Software for VM600 Series Machinery Protection Systems (MPS) FEATURES Configuration Software for VM600 Series Machinery Protection Systems (MPS) VM600 Configuration Software FEATURES Graphical User Interface software allowing maximum ease of use Running under Windows 98/NT/

More information

and High Temperature Velomitor * System

and High Temperature Velomitor * System 330750 and 330752 High Temperature Velomitor * System Product Datasheet Bently Nevada* Asset Condition Monitoring Description The standard 330500 Velomitor* Piezo-velocity Sensor has a limited temperature

More information

Proximity Transducers, Seismic Sensors and Accessories

Proximity Transducers, Seismic Sensors and Accessories 11mm Proximity Probe TM0110 System Linear range The 11mm probe has up to 4mm (160mil) linear range. The TM0110 probe is recommended when a longer linear range is required. The TM0110 proximity probe system

More information

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas technical datasheet technical datasheet MTL0 Displays Loop-powered indicators for hazardous areas Loop powered -0mA Field and panel mounting Environmental protection to IP7 Easy to configure Number of

More information

Velomitor * Piezo-velocity Sensor

Velomitor * Piezo-velocity Sensor Velomitor * Piezo-velocity Sensor Bently Nevada* Asset Condition Monitoring Description Velomitor * Piezo-velocity Sensors measure absolute (relative to free space) bearing housing, casing, or structural

More information

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12 0 4 Remote I/O 8 channels for controlling HART control valves and positioners Intrinsically safe outputs Ex ia IIC Galvanic isolation between outputs and system Open-circuit and short-circuit monitoring

More information

Trendmaster* Galvanic Isolator

Trendmaster* Galvanic Isolator 162459-01 Trendmaster* Galvanic Isolator Product Datasheet Bently Nevada* Asset Condition Monitoring Description The Trendmaster Galvanic Isolator enables the Trendmaster system to connect to intrinsically

More information

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015 Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in

More information

Proximity Transducers, Seismic Sensors and Accessories

Proximity Transducers, Seismic Sensors and Accessories PVTVM s Proximity Probe Selection Guide Part Number (Initial Prefix) TM0105 TM0180 TM0110 TM0120 Probe Tip Size 5mm 8mm 11mm 25mm Probe Model Type Standard, Standard, Standard, 7200 compatible 7200 compatible

More information

Intrinsically Safe Explosion Proof Barriers

Intrinsically Safe Explosion Proof Barriers Safety Intrinsically Safe Explosion Proof For more information on this product family, visit our website. Additional resources include: New and updated product information Downloadable software demos &

More information

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES Two cards providing 8 channels of temperature and process monitoring for VM 600 systems 8 channels of software selectable

More information

and High Temperature Velomitor * System

and High Temperature Velomitor * System 330750 and 330752 High Temperature Velomitor * System Bently Nevada* Asset Condition Monitoring Description The standard 330500 Velomitor* Piezo-velocity Sensor has a limited temperature range it can be

More information

General Specifications

General Specifications General Specifications Field Wireless Communication Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Communication Module. This product is based on the industrial

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications. EN ADAMCZEWSKI Elektronische Messtechnik GmbH Felix-Wankel-Str. 13 / 74374 Zaberfeld Tel. +49 (0)7046-875 Fax +49 (0)7046-7678 vertrieb@ad-messtechnik.de Operating Instructions Supply Isolation Amplifier

More information

3500 Internal Barriers Product Datasheet Bently Nevada* Asset Condition Monitoring

3500 Internal Barriers Product Datasheet Bently Nevada* Asset Condition Monitoring GE Measurement & Control 3500 Internal Barriers Product Datasheet Bently Nevada* Asset Condition Monitoring Description 3500 Internal Barriers are intrinsically safe interfaces that provide explosion protection

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

DeltaV Bulk Power Supplies

DeltaV Bulk Power Supplies DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration

More information

Online data sheet. FLOWSIC100 Flare MASS FLOW MEASURING DEVICES

Online data sheet. FLOWSIC100 Flare MASS FLOW MEASURING DEVICES Online data sheet FLOWSIC100 Flare MSS FLOW MESUING DEVICES MSS FLOW MESUING DEVICES B C D E F H I J K L M N O P Q S T C US Ordering information Type FLOWSIC100 Flare Part no. On request In accordance

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

DeltaV Bulk Power Supplies

DeltaV Bulk Power Supplies DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to

More information

LS 6600 Technical Datasheet

LS 6600 Technical Datasheet Technical Datasheet Switch for level detection and dry-run protection Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Small and compact KROHNE 06/2011-4001367301

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505 Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating

More information

Electronic pressure switch with display Model PSD-4

Electronic pressure switch with display Model PSD-4 Electronic pressure measurement Electronic pressure switch with display Model PSD-4 WIKA data sheet PE 81.86 Applications Machine tools Hydraulics and pneumatics Pumps and compressors Special-purpose machine

More information

SolConeX extra-low voltage flange socket

SolConeX extra-low voltage flange socket SolConeX extra-low voltage flange socket Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3

More information

OEM Products for Large Volume Production:

OEM Products for Large Volume Production: OEM Products OEM Products for Large Volume Production Areas of application for our OEM products for large volume production range from mobile and stationary industrial hydraulics, to pneumatics, machine

More information

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F 4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i / I.S. solenoid valves, piezo and booster valves Intrinsically safe outputs Ex ia IIC Additional input for "Outputs OFF" available

More information

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information Separating and protective instruments Separating and protective instruments VEGATRENN 149AEx Separator type KFDO Barrier type 9001 Product Information Content Content 1 Product description..........................................................................

More information

Flow Meter FC01-Ex FC01-Ex

Flow Meter FC01-Ex FC01-Ex Ex-Strömungsmesser Flow Meter FC0-Ex FC0-Ex Description The FC0-Ex has been designed to provide monitoring, detection and indication of flow speed, flow volume and medium temperature of liquids, gases

More information

Online data sheet. FW101 Ex SCATTERED LIGHT DUST MEASURING DEVICES

Online data sheet. FW101 Ex SCATTERED LIGHT DUST MEASURING DEVICES Online data sheet A B C D E F H I J K L M N O P Q R S T Ordering information Type Part no. On request The exact device specifications and performance data of the product may deviate from the information

More information

M E M O R A N D U M I.S.

M E M O R A N D U M I.S. Physikalisch-Technische Bundesanstalt Department 3.6 " Intrinsic safety and Safety of Systems" 38023 Braunschweig Germany P.O. Box 33 45 Tel. ++49 531 592-3630 Fax ++49 531 592-3605 M E M O R A N D U M

More information

200150, & Accelerometers Bently Nevada* Asset Condition Monitoring

200150, & Accelerometers Bently Nevada* Asset Condition Monitoring 200150, 200155 & 200157 Accelerometers Bently Nevada* Asset Condition Monitoring Description The 20015x Accelerometers are general purpose, wide frequency, case-mounted seismic transducers designed for

More information

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 1 Series 9475/ www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

Model 8042 Submersible Accelerometer

Model 8042 Submersible Accelerometer Model 8042 Submersible Accelerometer Submersible IEPE Accelerometer 16kHz Bandwidth IP68 Protection, >100meters Integral Cable, Tefzel & Urethane The Model 8042-01 is a submersible IEPE accelerometer designed

More information

Cable Entry Systems for Potentially Explosive Atmospheres

Cable Entry Systems for Potentially Explosive Atmospheres Cable Entry Systems for Potentially Explosive Atmospheres Directive 94/9/EC (ATEX) KEL-ER KVT 80 ATEX stands for ATmosphères EXplosives and is the short name for the European Directive 94/9/EC, regulating

More information

Zener Barriers Bulletin 937Z

Zener Barriers Bulletin 937Z Technical Data Zener Barriers Bulletin 937Z Topic Page Introduction 2 Mounting 2 Housing 3 Operating Principle 3 Specifications 6 Introduction Allen-Bradley Zener barriers are a cost-effective solution

More information

Operating Instructions

Operating Instructions Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on

More information

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2 Electronic pressure measurement Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2 WIKA data sheet PE 81.53 Applications Test bench construction Water jet

More information

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety PCe Type CAe Type Compliance Data: ATEX - IEC: ATEX IEC CE Ex ia IIC; Ex ib IIC T6 to T2 Ex td A21 T0 C to T290 C Ex de IIC Operating Temperatures: -40 C to +55 C (CAe) -55 C to +60 C (PCe) 223 ATX Product

More information

TEPI11 P/I signal converter

TEPI11 P/I signal converter Contents Data Sheet 10/18-0.15-EN Rev. A TEPI11 P/I signal converter Air pressure in current DMS sensor for gauge pressure Compact design Small dimensions, low weight Can be installed in any orientation

More information

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12 www.stahl.de > Fieldbus connection Industrial Ethernet PROFINET, Modbus TCP or EtherNet/IP with 100 MBit/s > Redundant Ethernet connection (Modbus TCP) is possible > Explosion protected, optical inherently

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters For operation in up to Zone 0 / 20 Features Measures humidity and temperature, outputs also dew point, mixing ratio, absolute humidity

More information

Inductive sensor with analog output BI15-M30-LI-EXI

Inductive sensor with analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection

More information

VariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing.

VariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing. Standard-Signal Isolation Amplifiers The world s first 3-port standard signal isolator in a 6-mm modular housing. The Task Isolation and, if required, conversion of 0... 20 ma, 4... 20 ma, and 0... 10

More information

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F 4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

CPU module for zone 2 Series 9442/35

CPU module for zone 2 Series 9442/35 > Supports PROFIBUS DP, PROFINET, Modbus TCP and Ethernet/IP; incl. HART transmission > RS-485 (max. 12 Mbps) and Ethernet (max. 100 Mbps) interfaces > Extensive diagnostics based on NE 107 > Support of

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through

More information

Installation & Operation Manual

Installation & Operation Manual Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas

More information

Velomitor* CT Velocity Transducer

Velomitor* CT Velocity Transducer 190501 Velomitor* CT Velocity Transducer Product Datasheet Bently Nevada* Asset Condition Monitoring Description The Velomitor CT Velocity Transducer is a low-frequency version of our standard Velomitor

More information

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x 1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical

More information

Flow Meter FC01-Ex-CA (compressed air/gas) Ex-Durchflussmesser FC01-Ex-CA

Flow Meter FC01-Ex-CA (compressed air/gas) Ex-Durchflussmesser FC01-Ex-CA Flow Meter FC0-Ex-CA (compressed air/gas) Ex-Durchflussmesser FC0-Ex-CA Description The FC0-Ex-CA has been designed to provide monitoring, detection and indication of flow speed, volume flow and temperature

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

KINAX WT720 absolute, programmable angular postion transmitter

KINAX WT720 absolute, programmable angular postion transmitter For industrial applications in rough environments KINAX WT720 is a robust, absolute angular position transmitter, which is particularly suited to applications in rough environments due to its unique capacitive

More information

Cable entry systems for potentially explosive atmospheres

Cable entry systems for potentially explosive atmospheres Cable entry systems for potentially explosive atmospheres Directive 94/9/EC (ATEX) ATEX stands for ATmosphère Explosible and is the short name for the European Directive 94/9/EC, regulating the market

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

HIGH ACCURACY PRESSURE TRANSDUCERS

HIGH ACCURACY PRESSURE TRANSDUCERS HIGH ACCURACY PRESSURE TRANSDUCERS PX409-100GV, RUGGEDIZED DESIGN For Aerospace, Automotive, Test and Industrial Applications U 0.08% BSL Includes Linearity Hysteresis and Repeatablity U Broad Temperature

More information

MANUAL Surge Protectors

MANUAL Surge Protectors PROCESS AUTOMATION MANUAL Surge Protectors DP-LBF-I1.36.DE and DP-LBF- I1.36.IE With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail Switch Amplifier Features Assembly -channel isolated barrier 4 V DC supply (Power Rail) Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL

More information

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2 Technical Data Communication Adapter Catalog Number 1719-AENTR I/O Module Catalog Numbers 1719-IJ, 1719-IBN8B, 1719-IF4HB, 1719-IR4B, 1719-IT4B, 1719-OB2, 1719-OB2L, 1719-CF4H Power Supply Catalog Number

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm Electronic pressure measurement Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm WIKA data sheet PE 81.25 for further approvals see page 5 MicroTronic

More information

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W Title INTRINSICALLY SAFE Ex ia PSU TYPE AC36W USER MANUAL Document Number 66-184-12 Issue 10 10 Update new logo and address 2017.10.18 CW CW PC 09 Added Um as 265V, Io up to 3.3A & IIB data 2017.08.21

More information

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2 Pressure Pressure sensor For highest pressure applications to 15,000 bar Model HP-2 WIKA data sheet PE 81.53 for further approvals see page 6 Applications Test bench construction Water jet cutting High-pressure

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

Programming unit VIATOR HART modems Model PU-H

Programming unit VIATOR HART modems Model PU-H Accessories Programming unit VIATOR HART modems Model PU-H WIKA data sheet SP 10.12 for further approvals see page 5 Applications Personal computer HART modem Communicates with all registered s Operates

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits RHM160 Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications Features Standard Pressure ratings up to 50bar (725 psi) Temperature ratings from -196 to 120 C (-320 to 248 F) Mass flow

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Explosion Proof Weighing System

Explosion Proof Weighing System Explosion Proof Weighing System Terminal ICS466x Safe and Compliant Intuitive and Easy to Use Versatile and Modular Ergonomic and Flexible Zone 1/21, Division 1 Safe and Accurate Weighing In Hazardous

More information

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-0 Application Single-acting or double-acting positioner for attachment to pneumatic control valves Reference variable Travels 4 to 20 ma 5.3 to 200 mm

More information

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern Operating Manual / IEC Explosion-Proofed Junction Boxes, Polyester Wallücker Bahndamm 7 DE- 32278 Kirchlengern Tel.: +49 5223 49107-0 Fax: +49 5223 49107-28 info@multi-box.com www.multi-box.com Contents

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

BA414DF Fieldbus indicator Single variable

BA414DF Fieldbus indicator Single variable FIELDBUS DISPLAYS BA4xx Series BA6xx Series Hazardous area Safe area NEW BA414DF indicator Single variable Shown with optional stainless legend plate Power Supply & Segment Coupler Host Intrinsically safe

More information

Sensor boxes SRBE Key features and product range overview

Sensor boxes SRBE Key features and product range overview Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications. Modular Housings for Hazardous Areas For transmission of 0(4)... 20-mA signals from hazardous areas or supply of intrinsically safe 2-wire transmitters. The Task The power supply/isolator is used to supply

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Electronic pressure switch with display For sanitary applications Model PSA-31

Electronic pressure switch with display For sanitary applications Model PSA-31 Electronic pressure measurement Electronic pressure switch with display For sanitary applications Model PSA-31 WIKA data sheet PE 81.85 Applications Food and beverage industry Pharmaceutical industry Filling

More information

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detection of angular range 0 to 360 P1-Ri-QR14 positioning element included in delivery Measuring

More information

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks Sensor boxes SRBC q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity

More information

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.

More information