CP 502. Piezoelectric pressure transducer. IECEx. » From the Vibro-Meter product line» Operating temperature range: 70 to 560 C ( 94 to F)
|
|
- Gillian Waters
- 6 years ago
- Views:
Transcription
1 Piezoelectric pressure transducer FEATURES» From the Vibro-Meter product line» Operating temperature range: 70 to 560 C ( 94 to F)» Pressure capability: up to 100 bar (1450 psi)» Pressure sensitivity: 90 pc / bar (6.2 pc / psi)» Frequency range: 0.5 Hz to 20 khz» Certified for use in potentially explosive atmospheres IECEx APPLICATIONS» Pressure pulsation monitoring in turbines DESCRIPTION The piezoelectric pressure transducer uses industrially grown single-crystal GaPO 4 (gallium phosphate) as the piezoelectric. This special material exhibits outstanding thermal behaviour with no pyroelectricity, thereby guaranteeing excellent signal quality and virtually constant sensitivity over the lifetime of the device. In addition, the transducer has a very low response threshold and uses internal case insulation. Combined, these features make the an extremely stable and reliable device that is suitable for the longterm monitoring of pressure pulsations in turbines. The transducer is fitted with an integral mineral insulated cable (twin conductors) that can be terminated with either a LEMO connector or a high-temperature connector developed by Vibro-Meter. Cable assemblies are available to connect the transducer to an IPC 704 signal conditioner. Information contained in this document may be subject to Export Control Regulations of the European Union, USA or other countries. Each recipient of this document is responsible for ensuring that transfer or use of any information contained in this document complies with all relevant Export Control Regulations. ECN N/A. Meggitt SA / / Version 2 / / E 1 / 7
2 DESCRIPTION (continued) The IPC 704 signal conditioner can convert the charge-based signal from the pressure transducer into a current or a voltage signal. Using a current modulated output allows transmission over longer distances, for example, up to 1 km when a GSI galvanic separation unit is used. Combining an IPC 704 signal conditioner with the pressure transducer produces a dynamic pressure measurement system that outputs a voltage or current signal that is proportional to the measured pressure. In this pressure measurement system, each component is interchangeable. The piezoelectric pressure transducer is designed to measure dynamic pressure levels and is particularly suitable for measuring pulsation pressures in the combustors of modern gas turbines. For specific applications, contact your nearest Meggitt Sensing Systems representative. SPECIFICATIONS General Input power requirements Signal transmission Signal processing : None : Charge output, 2-pole system, insulated from casing : Charge converter Operating (at +23 C ±5 C or F ±9 F) Sensitivity (minimum, at 2 Hz) Dynamic measuring range (random) Overload capacity (spikes) Linearity : 90 pc / bar (6.2 pc / psi) : to 50 bar (0.005 to 725 psi) : Up to 100 bar (1450 psi) (static + dynamic components) : 1% over the dynamic measuring range Acceleration sensitivity Axial : 2 mbar / g ( 0.03 psi / g) Radial : 0.25 mbar / g ( psi / g) Frequency response : 2 to Hz ± 5%. The lower cut-off frequency is determined by the electronics used. For example, the IPC 704 signal conditioner has configurable high-pass and low-pass filters. Resonant frequency : > 50 khz (along sensitive axis) Capacitance (nominal) Transducer : 30 pf pole / pole Cable : 270 pf / m pole / pole; 210 pf / m pole / ground Internal insulation resistance : > Ω at 25 C (77 F), > 10 6 Ω at 560 C (1040 F) Environmental Corrosion, humidity Operating temperature range Transducer Vibro-Meter high-temperature connector LEMO connector : NIMONIC alloy 90, hermetically welded : 70 to +560 C ( 94 to F) : 70 to +650 C ( 94 to F) : 55 to +155 C ( 67 to +311 F) 2 / 7 Meggitt SA / / Version 2 / / E
3 SPECIFICATIONS (continued) Explosive atmospheres Available in Ex approved versions for use in hazardous locations Type of protection Ex i: intrinsic safety Europe EC type examination certificate LCIE 10 ATEX 3039 X II 1G (Zones 0, 1, 2) Ex ia IIC T6 to T570 North America ccsaus certificate * ccsaus Class I, Div. 1, Groups A, B, C, D Ex /AEx ia IIC International IECEx certificate of conformity * LCI X Ex ia IIC T6 to T570 * No marking Type of protection Ex na: type of protection n (non sparking) Europe Voluntary type examination certificate LCIE 10 ATEX 1001 X II 3G (Zone 2) Ex na II T6 to T570 For specific parameters of the mode of protection concerned and special conditions for safe use, please refer to the certificates that are available from Meggitt SA on demand. Calibration ISO 9001 certified calibration at +20 C (+68 F) with dead weight tester (3, 6, 8, 10, 12, 30, 50 bar). Sensitivity and linearity are determined according to DIN Typical response curve 10 Sensitivity deviation (%) Temperature ( C) Note: Reference at +20 C (+68 F). Mechanical Connection type Mounting Fastening torque (to combustion chamber) : 2-pole hard line cable (Ø 3.2 mm), insulated from casing, with either a LEMO connector or a Vibro-Meter high-temperature connector : See the mounting adaptors in Accessories and refer to the CP xxx piezoelectric pressure transducers manual : 50 N m (443 inch-pounds) nominal. 60 N m (531 inch-pounds) maximum. Meggitt SA / / Version 2 / / E 3 / 7
4 MECHANICAL DRAWINGS with LEMO connector 38.8 ±2 Length: See Ordering information 36 ±2 Ø ± Ø ± ± ±0.5 M8 x 0.75 Tolerance: ±1% or ±100 mm (whichever is greater) Ø 3.2 ±0.2 Ø 9 ±0.5 Ø 8.9 ±0.1 MARKING Twin core MI-cable 2-pole LEMO connector type PCA.0S.302.CLLN32. Recommended mating connector LEMO type 0 for low noise cable Ø 4.2 mm, screen connected. + with Vibro-Meter high-temperature connector Ø ± Ø ±2 9 ± ± ±0.5 M8 x 0.75 Length: See Ordering information Tolerance: ±1% or ±100 mm (whichever is greater) Ø 3.2 ± ± ±1 7 / UNS-2A Ø 8.9 ±0.1 MARKING Twin core MI-cable 2-pole high-temperature connector PNR XX HEX. 7 / / 7 Meggitt SA / / Version 2 / / E
5 ORDERING INFORMATION To order please specify: Type Designation Cable length Ordering number Piezoelectric pressure transducer with LEMO connector 1 m m m m Piezoelectric pressure transducer with Vibro-Meter high-temperature connector 1 m m m m ACCESSORIES MA 104 mounting adaptor for with LEMO connector HEX. (Torque: 20 N m 2 ) M12 x A Ø 11 H9 ( ) A Nom to to to 23.5 Ra 0.8 MA internal pressure seal (PNR ) R 0.1 max Ø 9.5 H9 ( ) Ordering information Type Designation Ordering number MA 104 Mounting adaptor Note: The MA 104 mounting adaptor does not include the MA seal below. MA seal MA internal pressure seal Meggitt SA / / Version 2 / / E 5 / 7
6 ACCESSORIES (continued) MA 126 mounting adaptor for with Vibro-Meter high-temperature connector MA internal pressure seal (PNR ) 13.5 ±0.1 (41) MA external pressure seal (PNR ) 2 ±0.05 Ø 23 ±0.1 Ø M18 x 1.5 HEX. 16 Torque: 20 N m +10 / 2 HEX. 20 Torque: 60 N m +25 / 5 Ordering information Type Designation Ordering number MA 126 Mounting adaptor Note: The MA 126 mounting adaptor includes the MA seals below. MA seal MA internal pressure seal MA seal MA external pressure seal Cable assemblies EC 153 Refer to the data sheet EC 222 Refer to the data sheet EC 119 Refer to the data sheet Signal conditioner IPC 704 Refer to the data sheet Galvanic separation GSI 12x Refer to the data sheet 6 / 7 Meggitt SA / / Version 2 / / E
7 Headquartered in the UK, Meggitt PLC is a global engineering group specializing in extreme environment components and smart sub-systems for aerospace, defence and energy markets. Meggitt Sensing Systems is the operating division of Meggitt specializing in sensing and monitoring systems, which has operated through its antecedents since 1927 under the names of ECET, Endevco, Ferroperm Piezoceramics, Lodge Ignition, Sensorex, Vibro-Meter and Wilcoxon Research. Today, these operations are integrated under one strategic business unit called Meggitt Sensing Systems, headquartered in Switzerland and providing complete systems, using these renowned brands, from a single supply base. The Meggitt Sensing Systems facility in Fribourg, Switzerland was formerly known as Vibro-Meter SA, but is now Meggitt SA. This site produces a wide range of vibration and dynamic pressure sensors capable of operation in extreme environments, leading-edge microwave sensors, electronics monitoring systems and innovative software for aerospace and land-based turbo-machinery. All statements, technical information, drawings, performance rates and descriptions in this document, whilst stated in good faith, are issued for the sole purpose of giving an approximate indication of the products described in them, and are not binding on Meggitt SA unless expressly agreed in writing. Before acquiring this product, you must evaluate it and determine if it is suitable for your intended application. Unless otherwise expressly agreed in writing with Meggitt SA, you assume all risks and liability associated with its use. Any recommendations and advice given without charge, whilst given in good faith, are not binding on Meggitt SA. Meggitt Sensing Systems takes no responsibility for any statements related to the product which are not contained in a current Meggitt Sensing Systems publication, nor for any statements contained in extracts, summaries, translations or any other documents not authored by Meggitt Sensing Systems. We reserve the right to alter any part of this publication without prior notice. In this publication, a dot (.) is used as the decimal separator and thousands are separated by thin spaces. Example: Sales offices Your local agent Head office Meggitt Sensing Systems has offices in more than 30 countries. For a complete list, please visit our website. ABCD ABCD Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Tel: Fax: Meggitt SA / / Version 2 / / E 7 / 7
PA 152. Probe mounting adaptor (high temperature)
(high temperature) FEATURES» From the Vibro-Meter product line» For the external mounting of TQ proximity probes» Removable housing, with U-shaped retainer, that allows easier probe installation and gap
More informationIP 172. Interconnection protection mounting kit. » From the Vibro-Meter product line» Suitable for all TQ 4xx proximity measuring systems
Interconnection protection mounting kit FEATURES» From the Vibro-Meter product line» Suitable for all TQ 4xx proximity measuring systems» Fits coaxial cables from Ø 2.6 to Ø 3.6 mm using miniature coaxial
More informationIOC4T. Input / output card. » From the Vibro-Meter product line» Signal interface card with 6 channels, for the MPC4 machinery protection card
FEATURES» From the Vibro-Meter product line» Signal interface card with 6 channels, for the MPC4 machinery protection card» Screw terminal strip (48 terminals) for all input / output connections» Contains
More informationModular CPU card and input / output card
Modular CPU card and input / output card FEATURES» From the Vibro-Meter product line» One-Shot configuration of all VM600 cards using a direct Ethernet or RS-232 serial connection from an external computer,
More informationIECEx VSN010. VibroSmart DMS real-time Ethernet switch. » VibroSight compatible hardware from the. » Designed for operation with the VibroSmart
VibroSmart DMS real-time Ethernet switch FEATURES» VibroSight compatible hardware from the Vibro-Meter product line» Designed for operation with the VibroSmart distributed monitoring system (DMS)» Real-time
More informationVM600 system segregation and cyber security
Application note 021 VM600 system segregation and cyber security. VM600 rack-based systems have always been secure by design. Since its beginning, the VM600 system was conceived and designed to separate
More informationVM600 modular CPU card and input /output card
VM600 modular CPU card and input /output card FEATURES» From the Vibro-Meter product line» One-Shot configuration of VM600 cards using a direct Ethernet or RS-232 serial connection from an external computer,
More informationAMC8 and IOC8T Analog monitoring card and input / output card
Analog monitoring card and input / output card FEATURES AMC8» From the Vibro-Meter product line» Two cards providing 8 channels of temperature and process monitoring for VM600 systems» 8 channels of software
More informationVibroSmart DMS VSI010
VibroSmart DMS communications interface module FEATURES» VibroSight compatible hardware from the Vibro-Meter product line» Communications interfaces for industry standard fieldbuses: Modbus RTU, Profibus
More informationProximity Transducers, Seismic Sensors and Accessories
8mm, 5mm Proximity Probe TM0180 and TM0105 Systems Introduction to proximity probe transducers Proximity probe transducers are used to measure the static and dynamic distance between the target and the
More informationMeggitt Sensing Systems
VibroSmart distributed monitoring system Meggitt Sensing Systems VibroSmart distributed monitoring for industrial turbines, critical machinery and balance-of-plant equipment enables you to monitor more
More information8mm, 5mm Proximity Probe TM0180 and TM0105 Systems
8mm, 5mm Proximity Probe TM0180 and TM0105 Systems Introduction to proximity probe transducers Proximity probe transducers are used to measure the static and dynamic distance between the target and the
More informationVibroSight portable analyser VSPA. » From the Vibro-Meter product line» Portable condition monitoring system (CMS)
portable analyser VSPA FEATURES» From the Vibro-Meter product line» Portable condition monitoring system (CMS) based on proven VM600 system technology» Lightweight self-contained system with a rugged metal
More informationProximity Transducers, Seismic Sensors and Accessories
PVTVM s Proximity Selection Guide Part Number (Initial Prefix) TM0105 TM0180 TM0110 TM0120 Tip Size 5mm 8mm 11mm 25mm Model Type Standard, Standard, Standard, 7200 compatible 7200 compatible 7200 compatible
More informationVM600 Configuration Software. Configuration Software for VM600 Series Machinery Protection Systems (MPS) FEATURES
Configuration Software for VM600 Series Machinery Protection Systems (MPS) VM600 Configuration Software FEATURES Graphical User Interface software allowing maximum ease of use Running under Windows 98/NT/
More informationand High Temperature Velomitor * System
330750 and 330752 High Temperature Velomitor * System Product Datasheet Bently Nevada* Asset Condition Monitoring Description The standard 330500 Velomitor* Piezo-velocity Sensor has a limited temperature
More informationProximity Transducers, Seismic Sensors and Accessories
11mm Proximity Probe TM0110 System Linear range The 11mm probe has up to 4mm (160mil) linear range. The TM0110 probe is recommended when a longer linear range is required. The TM0110 proximity probe system
More informationtechnical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas
technical datasheet technical datasheet MTL0 Displays Loop-powered indicators for hazardous areas Loop powered -0mA Field and panel mounting Environmental protection to IP7 Easy to configure Number of
More informationVelomitor * Piezo-velocity Sensor
Velomitor * Piezo-velocity Sensor Bently Nevada* Asset Condition Monitoring Description Velomitor * Piezo-velocity Sensors measure absolute (relative to free space) bearing housing, casing, or structural
More information4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12
0 4 Remote I/O 8 channels for controlling HART control valves and positioners Intrinsically safe outputs Ex ia IIC Galvanic isolation between outputs and system Open-circuit and short-circuit monitoring
More informationTrendmaster* Galvanic Isolator
162459-01 Trendmaster* Galvanic Isolator Product Datasheet Bently Nevada* Asset Condition Monitoring Description The Trendmaster Galvanic Isolator enables the Trendmaster system to connect to intrinsically
More informationOperating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015
Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in
More informationProximity Transducers, Seismic Sensors and Accessories
PVTVM s Proximity Probe Selection Guide Part Number (Initial Prefix) TM0105 TM0180 TM0110 TM0120 Probe Tip Size 5mm 8mm 11mm 25mm Probe Model Type Standard, Standard, Standard, 7200 compatible 7200 compatible
More informationIntrinsically Safe Explosion Proof Barriers
Safety Intrinsically Safe Explosion Proof For more information on this product family, visit our website. Additional resources include: New and updated product information Downloadable software demos &
More informationAMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES
Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES Two cards providing 8 channels of temperature and process monitoring for VM 600 systems 8 channels of software selectable
More informationand High Temperature Velomitor * System
330750 and 330752 High Temperature Velomitor * System Bently Nevada* Asset Condition Monitoring Description The standard 330500 Velomitor* Piezo-velocity Sensor has a limited temperature range it can be
More informationGeneral Specifications
General Specifications Field Wireless Communication Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Communication Module. This product is based on the industrial
More informationFLEX Ex Spring Clamp Terminal Base
Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification
More informationADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.
EN ADAMCZEWSKI Elektronische Messtechnik GmbH Felix-Wankel-Str. 13 / 74374 Zaberfeld Tel. +49 (0)7046-875 Fax +49 (0)7046-7678 vertrieb@ad-messtechnik.de Operating Instructions Supply Isolation Amplifier
More information3500 Internal Barriers Product Datasheet Bently Nevada* Asset Condition Monitoring
GE Measurement & Control 3500 Internal Barriers Product Datasheet Bently Nevada* Asset Condition Monitoring Description 3500 Internal Barriers are intrinsically safe interfaces that provide explosion protection
More informationDigital Output Module 8-Channel Version for Zone 2 Series 9475/
> 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in
More informationDeltaV Bulk Power Supplies
DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration
More informationOnline data sheet. FLOWSIC100 Flare MASS FLOW MEASURING DEVICES
Online data sheet FLOWSIC100 Flare MSS FLOW MESUING DEVICES MSS FLOW MESUING DEVICES B C D E F H I J K L M N O P Q S T C US Ordering information Type FLOWSIC100 Flare Part no. On request In accordance
More informationAssembly MAU. MUX 4 Channels 8 Channels Zone 1
Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration
More informationDigital Output Module 8-Channel Version for Zone 2 Series 9475/
> 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in
More informationDeltaV Bulk Power Supplies
DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to
More informationLS 6600 Technical Datasheet
Technical Datasheet Switch for level detection and dry-run protection Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Small and compact KROHNE 06/2011-4001367301
More informationAssembly MAU. MUX 4 Channels 8 Channels Zone 1
Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.
More informationOperating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505
Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating
More informationElectronic pressure switch with display Model PSD-4
Electronic pressure measurement Electronic pressure switch with display Model PSD-4 WIKA data sheet PE 81.86 Applications Machine tools Hydraulics and pneumatics Pumps and compressors Special-purpose machine
More informationSolConeX extra-low voltage flange socket
SolConeX extra-low voltage flange socket Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3
More informationOEM Products for Large Volume Production:
OEM Products OEM Products for Large Volume Production Areas of application for our OEM products for large volume production range from mobile and stationary industrial hydraulics, to pneumatics, machine
More information4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F
4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i / I.S. solenoid valves, piezo and booster valves Intrinsically safe outputs Ex ia IIC Additional input for "Outputs OFF" available
More informationSeparating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information
Separating and protective instruments Separating and protective instruments VEGATRENN 149AEx Separator type KFDO Barrier type 9001 Product Information Content Content 1 Product description..........................................................................
More informationFlow Meter FC01-Ex FC01-Ex
Ex-Strömungsmesser Flow Meter FC0-Ex FC0-Ex Description The FC0-Ex has been designed to provide monitoring, detection and indication of flow speed, flow volume and medium temperature of liquids, gases
More informationOnline data sheet. FW101 Ex SCATTERED LIGHT DUST MEASURING DEVICES
Online data sheet A B C D E F H I J K L M N O P Q R S T Ordering information Type Part no. On request The exact device specifications and performance data of the product may deviate from the information
More informationM E M O R A N D U M I.S.
Physikalisch-Technische Bundesanstalt Department 3.6 " Intrinsic safety and Safety of Systems" 38023 Braunschweig Germany P.O. Box 33 45 Tel. ++49 531 592-3630 Fax ++49 531 592-3605 M E M O R A N D U M
More information200150, & Accelerometers Bently Nevada* Asset Condition Monitoring
200150, 200155 & 200157 Accelerometers Bently Nevada* Asset Condition Monitoring Description The 20015x Accelerometers are general purpose, wide frequency, case-mounted seismic transducers designed for
More informationDigital Output Module 8-Channel Version for Zone 1 Series 9475/
www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >
More informationModel 8042 Submersible Accelerometer
Model 8042 Submersible Accelerometer Submersible IEPE Accelerometer 16kHz Bandwidth IP68 Protection, >100meters Integral Cable, Tefzel & Urethane The Model 8042-01 is a submersible IEPE accelerometer designed
More informationCable Entry Systems for Potentially Explosive Atmospheres
Cable Entry Systems for Potentially Explosive Atmospheres Directive 94/9/EC (ATEX) KEL-ER KVT 80 ATEX stands for ATmosphères EXplosives and is the short name for the European Directive 94/9/EC, regulating
More informationZener Barriers Bulletin 937Z
Technical Data Zener Barriers Bulletin 937Z Topic Page Introduction 2 Mounting 2 Housing 3 Operating Principle 3 Specifications 6 Introduction Allen-Bradley Zener barriers are a cost-effective solution
More informationOperating Instructions
Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on
More informationPressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2
Electronic pressure measurement Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2 WIKA data sheet PE 81.53 Applications Test bench construction Water jet
More informationJunction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety
PCe Type CAe Type Compliance Data: ATEX - IEC: ATEX IEC CE Ex ia IIC; Ex ib IIC T6 to T2 Ex td A21 T0 C to T290 C Ex de IIC Operating Temperatures: -40 C to +55 C (CAe) -55 C to +60 C (PCe) 223 ATX Product
More informationTEPI11 P/I signal converter
Contents Data Sheet 10/18-0.15-EN Rev. A TEPI11 P/I signal converter Air pressure in current DMS sensor for gauge pressure Compact design Small dimensions, low weight Can be installed in any orientation
More informationEthernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12
www.stahl.de > Fieldbus connection Industrial Ethernet PROFINET, Modbus TCP or EtherNet/IP with 100 MBit/s > Redundant Ethernet connection (Modbus TCP) is possible > Explosion protected, optical inherently
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters For operation in up to Zone 0 / 20 Features Measures humidity and temperature, outputs also dew point, mixing ratio, absolute humidity
More informationInductive sensor with analog output BI15-M30-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection
More informationVariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing.
Standard-Signal Isolation Amplifiers The world s first 3-port standard signal isolator in a 6-mm modular housing. The Task Isolation and, if required, conversion of 0... 20 ma, 4... 20 ma, and 0... 10
More information4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F
4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to
More informationInductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position
More informationCPU module for zone 2 Series 9442/35
> Supports PROFIBUS DP, PROFINET, Modbus TCP and Ethernet/IP; incl. HART transmission > RS-485 (max. 12 Mbps) and Ethernet (max. 100 Mbps) interfaces > Extensive diagnostics based on NE 107 > Support of
More informationDigital Output Module 4-Channel Version for Zone 1 Series 9475/
www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through
More informationInstallation & Operation Manual
Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas
More informationVelomitor* CT Velocity Transducer
190501 Velomitor* CT Velocity Transducer Product Datasheet Bently Nevada* Asset Condition Monitoring Description The Velomitor CT Velocity Transducer is a low-frequency version of our standard Velomitor
More informationOperating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x
1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical
More informationFlow Meter FC01-Ex-CA (compressed air/gas) Ex-Durchflussmesser FC01-Ex-CA
Flow Meter FC0-Ex-CA (compressed air/gas) Ex-Durchflussmesser FC0-Ex-CA Description The FC0-Ex-CA has been designed to provide monitoring, detection and indication of flow speed, volume flow and temperature
More informationRAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description
I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules
More informationKINAX WT720 absolute, programmable angular postion transmitter
For industrial applications in rough environments KINAX WT720 is a robust, absolute angular position transmitter, which is particularly suited to applications in rough environments due to its unique capacitive
More informationCable entry systems for potentially explosive atmospheres
Cable entry systems for potentially explosive atmospheres Directive 94/9/EC (ATEX) ATEX stands for ATmosphère Explosible and is the short name for the European Directive 94/9/EC, regulating the market
More informationDigital Output Module 4-Channel Version for Zone 1 Series 9475/
www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >
More informationHIGH ACCURACY PRESSURE TRANSDUCERS
HIGH ACCURACY PRESSURE TRANSDUCERS PX409-100GV, RUGGEDIZED DESIGN For Aerospace, Automotive, Test and Industrial Applications U 0.08% BSL Includes Linearity Hysteresis and Repeatablity U Broad Temperature
More informationMANUAL Surge Protectors
PROCESS AUTOMATION MANUAL Surge Protectors DP-LBF-I1.36.DE and DP-LBF- I1.36.IE With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery
More informationAssembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail
Switch Amplifier Features Assembly -channel isolated barrier 4 V DC supply (Power Rail) Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL
More informationTerminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2
Technical Data Communication Adapter Catalog Number 1719-AENTR I/O Module Catalog Numbers 1719-IJ, 1719-IBN8B, 1719-IF4HB, 1719-IR4B, 1719-IT4B, 1719-OB2, 1719-OB2L, 1719-CF4H Power Supply Catalog Number
More informationMagnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationMiniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm
Electronic pressure measurement Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm WIKA data sheet PE 81.25 for further approvals see page 5 MicroTronic
More informationINTRINSICALLY SAFE Ex ia PSU TYPE AC36W
Title INTRINSICALLY SAFE Ex ia PSU TYPE AC36W USER MANUAL Document Number 66-184-12 Issue 10 10 Update new logo and address 2017.10.18 CW CW PC 09 Added Um as 265V, Io up to 3.3A & IIB data 2017.08.21
More informationPressure sensor For highest pressure applications to 15,000 bar Model HP-2
Pressure Pressure sensor For highest pressure applications to 15,000 bar Model HP-2 WIKA data sheet PE 81.53 for further approvals see page 6 Applications Test bench construction Water jet cutting High-pressure
More informationPI-EX-ME-2NAM/COC-24VDC
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC
More informationProgramming unit VIATOR HART modems Model PU-H
Accessories Programming unit VIATOR HART modems Model PU-H WIKA data sheet SP 10.12 for further approvals see page 5 Applications Personal computer HART modem Communicates with all registered s Operates
More informationMagnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationRHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits
RHM160 Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications Features Standard Pressure ratings up to 50bar (725 psi) Temperature ratings from -196 to 120 C (-320 to 248 F) Mass flow
More informationInductive sensor BI1.5-EG08-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationExplosion Proof Weighing System
Explosion Proof Weighing System Terminal ICS466x Safe and Compliant Intuitive and Easy to Use Versatile and Modular Ergonomic and Flexible Zone 1/21, Division 1 Safe and Accurate Weighing In Hazardous
More informationSeries 3730 Electropneumatic Positioner Type
Series 3730 Electropneumatic Positioner Type 3730-0 Application Single-acting or double-acting positioner for attachment to pneumatic control valves Reference variable Travels 4 to 20 ma 5.3 to 200 mm
More informationOperating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern
Operating Manual / IEC Explosion-Proofed Junction Boxes, Polyester Wallücker Bahndamm 7 DE- 32278 Kirchlengern Tel.: +49 5223 49107-0 Fax: +49 5223 49107-28 info@multi-box.com www.multi-box.com Contents
More informationInductive sensor For rotary actuators NI4-DSU35TC-2Y1X2
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationBA414DF Fieldbus indicator Single variable
FIELDBUS DISPLAYS BA4xx Series BA6xx Series Hazardous area Safe area NEW BA414DF indicator Single variable Shown with optional stainless legend plate Power Supply & Segment Coupler Host Intrinsically safe
More informationSensor boxes SRBE Key features and product range overview
Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic
More informationMINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description
Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,
More informationWG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.
Modular Housings for Hazardous Areas For transmission of 0(4)... 20-mA signals from hazardous areas or supply of intrinsically safe 2-wire transmitters. The Task The power supply/isolator is used to supply
More informationInductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationElectronic pressure switch with display For sanitary applications Model PSA-31
Electronic pressure measurement Electronic pressure switch with display For sanitary applications Model PSA-31 WIKA data sheet PE 81.85 Applications Food and beverage industry Pharmaceutical industry Filling
More informationInductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi
ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detection of angular range 0 to 360 P1-Ri-QR14 positioning element included in delivery Measuring
More informationSensor boxes SRBC. Festo core product range Covers 80% of your automation tasks
Sensor boxes SRBC q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity
More informationMagnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.
More information