USER MANUAL. V1.0.2, Rev A

Size: px
Start display at page:

Download "USER MANUAL. V1.0.2, Rev A"

Transcription

1 1 USER MANUAL V1.0.2, Rev A

2 2

3 Contenido PRODUCT OVERVIEW INSTALLATION Selecting a Mounting Location MOUNTING THE ALBACOMBI UNIT DIN Rail Mounting Connecting to a NMEA2000 Network NMEA2000 Networks NMEA2000 Minimum Network Requirements TACHO INPUT CONNECTIONS CONFIGURING THE ALBACOMBI DEVICE General Option Channel Options RPM Channel PTC1000 Option Volt/Resistive Input Shunt Input Voltage Input Output Option N2K Option PGN : Engine Rapide Update PGN : Engine Parameters Dynamic PGN : Battery Status PGN : Fluid Level PGN : Temperature PGN : Pressure Displays Option FULL-SCREEN OPTION HARDWARE TEST AND UPDATE DEVICE OPTIONS SPECIFICATIONS... 35

4 Company Information EMMI NETWORK S.L. CALLE DELS FURS, GANDiA, VALENCIA SPAIN No part of this document may be reproduced in any form without the written permission of the copyright owner. The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. EMMI Network SL shall have no liability for any error or damage of any kind resulting from the use of this document. The information provided in this document concerning capacity, suitability and performance shall not be considered commercially binding. Please note that all capacity figures and dimensioning methods are based on EMMI Network s SL own models of how devices behave in a network. The document is intended to be used by professionally trained personnel. It is strongly recommended to involve EMMI Network SL in discussions covering the contents of this document. Any feedback that may help EMMI Network SL improve the documentation and information methods is welcome. Product Disposal Please dispose of this product in accordance with the WEEE Directive. The product should be taken to a registered establishment for the disposal of electronic equipment.

5 5 PRODUCT OVERVIEW The new AlbaCombi is a second generation device, built following our successful Alba line of converters, that translate analogue signals from all over the boat to an NMEA2000 bus. The unit has been designed to connect in parallel to an existing gauge, so existing instruments can still be used. The AlbaCombi can be used to get engine data, tank levels, alarm status, generic pressure and temperature indications from any 4-20mA sensor. You get twelve 0V to 32V inputs that can be used for anything from reading voltages of batteries to interfacing with any analogue gauges. Six channels can be configured to measure resistance from any industry standard engine sensor. Also there are two RPM inputs, one PTC temperature input, one shunt and two relay outputs. All twelve resistance and voltage channels have comprehensive calibration that allow you to create an 8 point calibration table or select a predefined industry standard calibration table for most common sensors and gauges. The AlbaCombi has an Ethernet port that will allow web based calibration. Just connect your laptop to the AlbaCombi via Ethernet and you will get to the calibration and testing page. No calibration tools or special interfaces are required. This device is future proof and can be upgraded in the field via its ethernet port. See the configuration instructions to find which senders and PGNs are supported. The instructions can be found on the website at 1. Select mounting location: Ensure the AlbaCombi can be mounted in a suitable location between the NMEA2000 bus and the senders or gauges. 2. Connect the AlbaCombi to the NMEA2000 network 3. Connect the Gauge inputs 4. Connect the Power to the AlbaCombi 5. Configure the AlbaCombi

6 1. INSTALLATION 1.1 Selecting a Mounting Location The following figure shows an example installation. This gives an idea of the connections that need to be made to install the AlbaCombi. All these connections need to be considered before selecting an installation location. Resistive Mode 12Vdc RPM (+) (-)

7 2. MOUNTING THE ALBACOMBI UNIT 2.1 DIN Rail Mounting Requirements: A top hat rail, type EN or a G section rail, type EN Mounting using a different rail type or an alternative mounting kit may breach the terms and conditions of the guarantee. 2.2 Connecting to a NMEA2000 Network

8 2.2.1 NMEA2000 Networks NMEA2000 devices will only communicate with each other when connected to a powered and correctly terminated NMEA2000 network. All networks need to be powered and terminated correctly to allow data to be transmitted reliably on the network. T-Pieces are needed to connect each device to the network. Additional cable lengths can be used between any of the connectors to extend the length of the network. Ensure the NMEA2000 rules for cable length are adhered to. Cable Type Per drop cable Sum of all drop cables Micro Backbone (terminator to terminator) Mini Backbone (terminator to terminator) Max Length 6 m 72 m 100 m 200 m NMEA2000 Minimum Network Requirements All NMEA2000 networks require a 12 V DC supply. In addition, a correctly functioning network will require the following components : 1 x Power-T 2 x Terminating Resistors 2 x T-Pieces (one per connected device) 1 x NMEA2000 compatible display All the required network parts can be supplied by Emmi Network S.L

9 3. TACHO INPUT CONNECTIONS Ignition Coil Connect the negative of the ignition coil to the positive RPM input of the AlbaCombi. Connect GND to input GND of the AlbaCombi Alternator Connect the w connection of the alternator to the AlbaCombi RPM positive input of the AlbaCombi (input (input 5 or 6). Connect GND input of the alternator to the input 4 Hall Effect and Electronic Pulse Senders Connect the signal line of the sender to the positive input on the AlbaCombi Connect GND to GND input of the AlbaCombi

10 4. CONFIGURING THE ALBACOMBI DEVICE Make all connections. See the pin out of your device: Configure your AlbaCombi: Connect your laptop to Ethernet port. Open the browser navigator, preferred Chrome and go to the following address: The first windows that you will see are the FullView page: The gauges that you will see are an example

11 4.1 General Option In this option you can change the Ethernet configuration from the AlbaCombi, enable/disable the DHCP server and configure the IP address. The default configuration is DHCP server disabled and IP address The default NMEA address is 9. Note that if you connect two or more AlbaCombi, you must change the NMEA address, for example: you have two AlbaCombi connected on your NMEA network. One will have the NMEA Address 9 and other will be configured with NMEA Address 10. If you make any change, press Save button and then press Reset

12 4.2 Channel Options In order to configure each connected input, please select the channel, as shown on the following screen. Once selected please configure it.

13 4.2.1 RPM Channel You must configure all fields: Name: the name of the channel. Signal from: In case of RPM signal, the signal is sent by one engine. Physic Variable: In case of RPM, the only option is Rotation Rate. Units: RPM Limits high and Low: these limits will be used to set an alarm. Filter Level: Please indicate if the level measurement has been made with low, medium or high level. Sensor Type: you count with some predefined sensors. You can choose a sensor type and make some changes. If you press on Measure, the current value of the input will be shown.

14 You can click on RAW and see the current value or you can write the theoretical value of the sensor output which corresponds to the measurement. The Calibrated button is used to test if your calibration table is correct. Note that you must click on Save before doing the test. Example: If you have saved the following calibration table: Measured (pulse per cycle) RPM We assume that the sensor manufacturer indicates these values, therefore 3000 rpm we should have a measure of 300 pulses per cycle. You can accelerate to see that you have 300 cycles per second (by pressing on Raw until that value appears), then press Calibrated and see the value, if it is about 3000 rpm, the calibration table is correct. Press SAVE when all changes have been made.

15 4.2.2 PTC1000 Option Signal from: you can select if the sensor measures the temperature from the engine, battery or it s a general temperature. It is important to select the correct sensor because otherwise when configuring the corresponding PGN you won t have the choice to select this parameter, for instance, if you choose Engine, the value will be sent to the NMEA network though the PGN and PGN Physic Variable: In this case, the PTC sensor only works with temperature parameters. Units: Select between ºC or K. Limits high and low: these limits will be used to set an alarm. Filter Level: Please indicate if the level measurement has been made with low, medium or high level. Sensor Type: you have some predefined sensors. You can choose a sensor type and make some changes on calibration table. If you press on Measured you will see the current value:

16 You can click on RAW and see the current value or you can write the theoretical value of the sensor output corresponding to the measurement. The Calibrated button is used to test if your calibration table is correct. Note that you must click on Save before make the test. Example: You has saved the following calibration table: MEASURED (Ohms) VALUE (Tª) (ºC) temp temp; 180; 95 temp; 100; 50 temp; 10; 15 We assume that the sensor manufacturer indicates these values. In this way to 70 ºC we must have a measure of 140 Ohms. You switch on the engine that you have 140 Ohms (you pressing on Measured until that value), then press Calibrated and see the value, if it is about 70ºC, the calibration table is correct. Note that X-axis values (MEASURE) must increase, from smallest to largest value

17 4.2.3 Volt/Resistive Input You have six inputs like this. In the Channel screen you will see if the input has been configured on voltage o resistive mode Signal from: You can select the parameter that the input will measure; engine, battery, general fluid, general temperature, general pressure, switch bank or general fluid. Signal from Engine Battery General Fluid General Temperature General Pressure Switch Bank Physic Variable Rotation Rate Pressure Engine Tilt Temperature Voltage Fluid flow Temperature Voltage Current General fluid General temperature General Pressure Binary Limits high and low: these limits will be used to set an alarm. Filter Level: please indicate if the level measurement has been made with low, medium or high level.

18 Sensor Type: You have some predefined sensors. You can choose a sensor type and make some changes. Supply Correction (only on voltage input, not available on resistance mode): You can activate the supply correction using a voltage input (Correction Channel)

19 4.2.4 Shunt Input The shunt is a sensor that measures the load or unload current in a battery, and it must have the right dimensions to stand the maximum current it it supposed to measure. Signal from: This parameter can only be obtained from the battery, therefore, will be the only option in the drop-down. Physic Variable: the only option is current. Units: ma or A Limits high and low: these limits will be used to set an alarm. Filter Level: Indicate if the measures filter has been made with a low, medium or high level. Sensor Type: You have some predefined sensors. You can choose a sensor type and make some changes. If you press on Measured you will see the current value: You can click on Measured and see the current value or you can write the theoretical value of the sensor output corresponding to the measurement. The Calibrated button is used to test if your calibration table is correct. Note that you must click on Save before makingthe test.

20 4.2.5 Voltage Input Signal from: You can select the parameter that the input will measure: engine, battery, general fluid, general temperature, general pressure, switch bank or general fluid. Signal from Engine Battery General Fluid General Temperature General Pressure Physic Variable Rotation Rate Pressure Engine Tilt Temperature Voltage Fluid flow Temperature Voltage Current General fluid General temperature General Pressure

21 Limits high and low: these limits will be used to set an alarm. Filter Level: please indicate if the level measurement has been made with low, medium or high level. Sensor Type: You have some predefined sensors. You can choose a sensor type and make some changes. Supply Correction: You can activate the supply correction using a voltage input (Correction Channel)

22 4.3 Output Option You have 2 relay outputs. If you wish to configure alarms: Name: please write down the alarm s name Output Type: you have 3 options: o Manual: You can switch on/off the relay o NMEA2000: allows to act on a device connected to the NMEA network when the alarm is activated o Alarm: the alarm up and down values are only to be configured on screen. Limits high/low: these limits have already been configured in the Channel Option. Activation Rule: You can choose the condition for which the alarm is activated.

23 4.4 N2K Option In this section you must configure the PGN to send through the NMEA network PGN : Engine Rapide Update Engine Speed (RPM) Boost Pressure 7FFFFF Instance: The instance indicates the engine (port, starboard, forward, etc..) Engine Speed: if you have a RPM input, please select it. Engine Boost: if you have configured a pressure input from engine, please select it. Tilt/trim: same as before. Active PGN: If you select this option, the AlbaCombi will send this information through N2K network and the information will be shown on your multifunction display on board. RPM

24 4.4.2 PGN : Engine Parameters Dynamic Engine Oil Pressure Oil Temperature Engine Temperature Alternator Voltage Coolant Temperature The following PGNs which are mentioned in the standard NMEA will be displayed: Instance: The instance indicates the engine values (port, starboard, forward, etc..) Oil Pressure: if you have configured a pressure input from engine, please select it. Engine Temperature: If you have configured a temperature sensor from engine, please select it. Proceed in the same way with the rest of parameters. Active PGN: If you select this option, the AlbaCombi will send this information through N2K network and it will be shown on a muntifunction display on board.

25 4.4.3 PGN : Battery Status Battery Instance Voltage Current Temperature FF Instance: this is a very important field. If you have two or more batteries on your vessel, each battery bank should be configured with a different distance. Range 0 to 250 for valid position fixes. Voltage: Select the input where you have connected the battery voltage on your AlbaCombi. Current: Select your shunt input channel. Temperature: Select the temperature input from battery bank. Note, enable the Active PGN if you wish to display the parameters in your on board NMEA N2K multifunction display.

26 4.4.4 PGN : Fluid Level Fluid Instance Fluid Type Fluid Level Tank Capacity Reserved FF Instance: this is a very important field when you have two or more level sensors on your vessel, each sensor should be configured with a different instance. Capacity: (cubic meters) You must define the capacity of your tank. Type: You can select the type as NMEA standard ndicates (Fuel, fresh water, waste water, live well, oil and black levels). Level: Select the correct input. Note, enable the Active PGN if you wish to display the parameters in your on board NMEA N2K multifunction display.

27 4.4.5 PGN : Temperature SID Instance nº Temperature Source Actual Temperature (ºK) Temperature Set Reserved FF Instance: this is a very important field if you have two or more temperature sensors on your vessel, each sensor must configure with different instances. Source: You can select the source type as NMEA standard indicates:

28 Actual Value: Select the correct input.

29 4.4.6 PGN : Pressure SID Instance nº Pressure Source Pressure (Pa) Reserved FF Instance: this is a very important field if you have two or more pressure sensors on your vessel, each sensor must configure with different instances. Source: You can select the source type as NMEA standard indicates: Actual Value: Select the correct input.

30 4.7 Displays Option In this option you will configure the parameters to monitoring in the FullView Option. Select the first display to configure it: Select Measurement: You will choose any input that you had connected to AlbaCombi Title: Display name, you will see underneath the gauge. Label: name on the gauge label. Display Type: when displaying the information you can select between the following forms: o Gauge:

31 o Graph: o Display: Activate Full-View: If you select this option, you will see the parameter in the full screen option from AlbaCombi. Alarms zone: It is important to set the alarm values as it will define the scale limits on your display. Please find hereby examples on how to set these limits: MIN MAX Green Zone Yellow Zone Red Zone Note that the upper limit has to be equal to the area above. lower limit of the In case you wish only two zones, the configuration is as follows: MIN MAX Green Zone Yellow Zone Red Zone Press Save when the you have finished configuring the display.

32 4.8 FULL-SCREEN OPTION The default page of AlbaCombi will be displayed as shown below. All displays that you have configured before will be displayed. This option can work in parallel to a NMEA display. You can view this data in NMEA display installed in your boat, and also from any device connected to the same Ethernet network as the AlbaCombi internet based page. Press on the padlock icon to block/unlock the screen. In unlock mode you will can move the indicators.

33 5. HARDWARE TEST AND UPDATE DEVICE OPTIONS Before making all connections, please follow the next steps: 1. Change the state of the switch on Hardware Test Mode: Switch 1 on, switch 2 off and then press reset button ON Please access the following URL on your PC: 2. You will see the Hardware Test Option:

34 If you connect the test board, the device will be a hardware test and in your web page you will see the checkbox marked if the result has been positive. To update the AlbaCombi device: 1. Download the last firmware version from: and save it on your PC 2. Enter in Installer Mode on your AlbaCombi device. 3. Go to: 3. Select the Firmware Update option: 4. Select the.xin file saved on step Press Update.

35 SPECIFICATIONS SPECIFICATIONS IN / OUT Analogue Inputs Analogue input precision Relay out Data in/out 6 x Resistive (0 to 600 Ohm) or Voltage (0-32V) 6 x Voltage (0-32V) 2 x RPM W signal or magnetic sensor 1 x Precision temperature PTC x 100mV current shunt 1% or better 2 x Open collector output Ethernet port (calibration and monitoring) RS232 (module programming) Isolated CAN NMEA2000 NMEA2000 Parameter Group Numbers (PGN s) Periodic PGN Engine Parameters, Rapid Update PGN Engine Parameters, Dynamic PGN Battery Status PGN Fluid Level PGN Temperature PGN Actual Pressure PGN Binary Switch Bank Status PGN Binary Switch Bank Control ELECTRIC SPECIFICATIONS Tension 9-18V DC from the NMEA2000 bus Consumption 150mA Equivalent load 3 LEN as per NMEA2000 MECHANICAL SPECIFICATIONS Size 104mm x 86mm x 588mm (DIN size 6) Weight 230g Mounting DIN Rail Clip EN Case material Top PC/UL 94-V0, Base PPO / UL 94-V0 ENVIROMENTAL SPECIFICATIONS Protection Class EN60529 IP20 Working temperature -15C to +55ºC Storage temperature -25ºC to +85ºC Relative humidity 93% 40ºC IEC Vibration ±1mm 7m/s 2 IEC Corrosion 4x7 40ºC, 95%HR after two hour salt spray IEC Emission IEC E.M.C. Immunity IEC

Albatross On Board v1.4 Software User Guide

Albatross On Board v1.4 Software User Guide Albatross Control System v1.4 Albatross On Board v1.4 Software User Guide PRELIMINARY Rev.PA1 No part of this document may be reproduced in any form without the written permission of the copyright owner.

More information

Albatross Control System Installation

Albatross Control System Installation Albatross Control System v1.4 Albatross Control System Installation PRELIMINARY Rev.PA1 No part of this document may be reproduced in any form without the written permission of the copyright owner. The

More information

Comprehensive Modular Genset Controller

Comprehensive Modular Genset Controller Inteligen Learn More Comprehensive Modular Genset Controller Brief Description The Inteligen is a comprehensive controller for single and multiple generating sets operating in standby or parallel to the

More information

InteliLite MRS17 Click Here to Learn More

InteliLite MRS17 Click Here to Learn More InteliLite MRS17 Click Here to Learn More Comprehensive Genset Controller Brief Description The InteliLite is a cost effective controller for generator sets in stand-by and prime power applications. The

More information

EMU-1. User Manual. Engine Monitoring Unit Analogue to NMEA For variant: EMU-1-BAS, Rev A. Issue 1.03

EMU-1. User Manual. Engine Monitoring Unit Analogue to NMEA For variant: EMU-1-BAS, Rev A. Issue 1.03 EMU-1 Engine Monitoring Unit Analogue to NMEA 2000 User Manual For variant: EMU-1-BAS, Rev A Issue 1.03 NMEA 2000 Engine Monitoring Unit - EMU-1 Contents Company information 4 Important Notices 5 Trademarks

More information

Quick Installation Guide

Quick Installation Guide Manual# 1100274 Quick Installation Guide SDU 410 Safety Unit Quick Installation Guide for SDU 410 Safety Unit ~~~ Revision 1.1 Revised November 10, 2016 Revision history: Rev. Date Description 1.0 04.2012

More information

Manual# Installation Manual SDU 410. Safety Shutdown Unit

Manual# Installation Manual SDU 410. Safety Shutdown Unit Manual# 1100641 Installation Manual SDU 410 Safety Shutdown Unit Installation Manual for SDU 410 ~~~ Safety Shutdown Unit Revision 1.0 Revised August 31, 2017 Revision history: Rev. Date Description 1.0

More information

Features and Benefits. Certifications

Features and Benefits. Certifications iologik R1200 Series RS-485 remote I/O Features and Benefits Dual RS-485 remote I/O with built-in repeater Supports the installation of multidrop communications parameters Install communications parameters

More information

iologik 4000 Series (M) Modules

iologik 4000 Series (M) Modules iologik 4000 Series (M) s Remote I/O modules Features and Benefits I/O expansion without a backplane Active communication with MX-AOPC UA Server Supports SNMP v1/v2c Easy configuration with Modular ioadmin

More information

AB Axis Industries. Use

AB Axis Industries. Use AB Axis Industries PULSE ADAPTER ENCO PULSE The ENCO PULSE pulse adapter acquires and handles the pulses from consumption meters with pulse output and transmits the data to a network of AMR system. Use

More information

T500 DUALTACH. JAQUET T500 DualTach. 2 channel measurement & monitoring instrument 2 CHANNEL TACHOMETER I N C H A R G E O F S P E E D.

T500 DUALTACH. JAQUET T500 DualTach. 2 channel measurement & monitoring instrument 2 CHANNEL TACHOMETER I N C H A R G E O F S P E E D. 1-08 T500 DUALTACH 2 CHANNEL TACHOMETER JAQUET T500 DualTach 2 channel measurement & monitoring instrument JAQUET T500 DualTach 2 channel measurement and monitoring instrument for demanding machine protection

More information

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Active communication with patented MX-AOPC UA Server and Active OPC server Smart alarm management with email, SNMP traps, TCP, UDP Save

More information

Features and Benefits. Certifications

Features and Benefits. Certifications iologik E2200 Series Smart Ethernet remote I/O with Click&Go Logic Features and Benefits Front-end intelligence with patented Click&Go control logic, up to 24 rules Active communication with MX-AOPC UA

More information

ECI1. COMPASS display. ECI1-REV For latest update: Electronic Compass Indicator ECS1

ECI1. COMPASS display. ECI1-REV For latest update:   Electronic Compass Indicator ECS1 ECI1 COMPASS display Electronic Compass Indicator ECS1 ECI1-REV. 1.3 20-12-2004 For latest update: www.elproma.com/compass Contents 1 Introduction... 1 1.1 Package contents... 1 2 Working... 2 2.1 The

More information

iothinx 4500 Series (45MR) Modules

iothinx 4500 Series (45MR) Modules iothinx 4500 Series (45MR) Modules Modules for iothinx 4500 Series Feature and Benefits Easy tool-free installation and removal Built-in LED indicators for IO channels Wide operating temperature range:

More information

Model RS11 v2.0 CANbus Engine Data Converter NoLand Engineering, Inc. 1. Introduction

Model RS11 v2.0 CANbus Engine Data Converter NoLand Engineering, Inc. 1. Introduction Model RS11 v2.0 CANbus Engine Data Converter NoLand Engineering, Inc. TABLE of CONTENTS 1. Introduction 2. General Description 3. Installation 4. Operation 5. Technical Specifications 6. Warranty Appendix

More information

Process displays For current and voltage

Process displays For current and voltage Features Voltage input TRMS-AC/DC up to 600 V Current input AC/DC 1 A, 5 A and shunt (precision resistor) 60 or 100 mv With 2 or 4 limits Display range can be linearised Min, Max, Hold functions 4 20 ma

More information

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS Characteristics battery control module - 24..28.8 V DC - 24 V - 20 A - for regulated SMPS Main Range of product Product or component type Input voltage Output voltage Maximum output current Phaseo Battery

More information

Comprehensive Modular Genset Controller

Comprehensive Modular Genset Controller InteliGen Comprehensive Modular Genset Controller Brief Description InteliGen is a comprehensive AMF-controller for single and multiple generating sets operating in standby or parallel modes. A modular

More information

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch User-definable Modbus/TCP Slave addressing Supports EtherNet/IP* adapter mode Supports RESTful API for IIoT applications 2-port Ethernet

More information

PowerView TM Model PV350 and PV380. Operations Manual Section 78

PowerView TM Model PV350 and PV380. Operations Manual Section 78 PowerView TM Model PV350 and PV380 Operations Manual 00-02-0879 2012-11-30 Section 78 In order to consistently bring you the highest quality, full featured products, we reserve the right to change our

More information

Model Number: 4212-PK-045Sensor Connections* SHIELD Silver/clear wire DEBRIS MEASURE RED DEBRIS REF BLUE OIL SIGNAL GREEN OIL REF WHITE TEMP ORANGE PROBE GND BLACK Wire 26 AWG PTFE 3G210 screened with

More information

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Active communication with patented MX-AOPC UA Server and Active OPC Server 2 switched Ethernet ports for daisy-chain topologies Easy

More information

POWERWISE INDAC SETUP MANUAL

POWERWISE INDAC SETUP MANUAL POWERWISE INDAC SETUP MANUAL REVISION: 2.2 INDAC & EMONITOR GATEWAY An installation guide for the PowerWise indac. 2013 PowerWise, Inc. This manual may contain proprietary information about the product

More information

Digital Overspeed Protection System with PROFIBUS -DP interface DOPS, DOPS AS, DOPS TS

Digital Overspeed Protection System with PROFIBUS -DP interface DOPS, DOPS AS, DOPS TS Digital Overspeed Protection System with PROFIBUS -DP interface DOPS, DOPS AS, DOPS TS Application: The speed measurement and overspeed protection systems DOPS and DOPS AS serve the measurement of speeds

More information

Multifunction Transducer MT440

Multifunction Transducer MT440 Multifunction Transducer MT440 Voltage and current auto range measurements up to 600V, 12.5A Universal wide auxiliary power supply range 24 300 Vdc, 40 276 Vac Power accuracy class 0.5 (EN 60 688), Up

More information

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.

More information

T600 TACHOMETER MultiTasker - a measurement & monitoring instrument with 2 frequency and 1 analog inputs

T600 TACHOMETER MultiTasker - a measurement & monitoring instrument with 2 frequency and 1 analog inputs TACHOMETER MultiTasker - a measurement & monitoring instrument with 2 frequency and 1 analog inputs Features High accuracy speed measurement: 0.002% for limits and 0.1% referenced to 20 ma 2 frequency

More information

TM221CE24R controller M IO relay Ethernet

TM221CE24R controller M IO relay Ethernet Product data sheet Characteristics TM221CE24R controller M221 24 IO relay Ethernet Complementary Main Discrete I/O number 24 Number of I/O expansion module Supply voltage limits Network frequency Inrush

More information

Feature and Benefits. Certifications

Feature and Benefits. Certifications UC-2100 Series Arm-based palm-sized industrial computing platform for IIoT applications Feature and Benefits Armv7 Cortex-A8 1000 MHz processor 1 or 2 auto-sensing 10/100 Mbps Ethernet ports Gigabit Ethernet

More information

EP-65R Fluid Level. Electronic Sensor. Installation, Configuration and Calibration Instructions

EP-65R Fluid Level. Electronic Sensor. Installation, Configuration and Calibration Instructions Pub. 988-0154-372 EP-65R Fluid Level Electronic Sensor Installation, Configuration and Calibration Instructions This document shows how to install an EP-65R Fluid Level sensor and how to connect it to

More information

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU)

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU) Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU) Rev. 2 September 2012 Part No. 4417552 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax :

More information

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series TEMPSEN DEVICES Plot No : 2&3, Balaji Nagar, 4 th Street, Mettukuppam, Thoraipakkam, Chennai-600097 Tele fax : +91-44-24581758,Mobil

More information

IS42J. Operator Manual. ENGLISH

IS42J. Operator Manual.   ENGLISH IS42J Operator Manual ENGLISH www.simrad-yachting.com Preface Disclaimer As Navico is continuously improving this product, we retain the right to make changes to the product at any time which may not

More information

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

Installation and commissioning guide SmartLink PSD Power Supply Module (DC) Installation and commissioning guide SmartLink PSD Power Supply Module (DC) Rev. 1 September 2012 Part No. 4417551 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15

More information

Inclination sensors 1-dimensional, measuring range

Inclination sensors 1-dimensional, measuring range Features Size 52 mm MEMS capacitive measuring principle EN13849 compliant firmware E1 compliant design Interface CANopen, SAE J1939, Analog Connection M12 and cable Protection up to IP 69K Optional GIM500R

More information

Modbus TCP/RTU Gateway

Modbus TCP/RTU Gateway Modbus TCP/RTU Gateway Hardware Installation Guide for models IE-GW-MB-2TX-1RS232/485 IE-GWT-MB-2TX-1RS232/485 Second Edition, June 2014 1516600000/01/06.14 Important note: The detailed user manual, additional

More information

TM221CE40T controller M IO transistor PNP Ethernet

TM221CE40T controller M IO transistor PNP Ethernet Product data sheet Characteristics TM221CE40T controller M221 40 IO transistor PNP Ethernet Complementary Main Discrete I/O number 40 Number of I/O expansion module Supply voltage limits Inrush current

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 50 KB General information

More information

Engine Controller EC-1

Engine Controller EC-1 Engine Controller 4921240292E Standard functions Engine control Engine monitoring DEIF A/S Start preparation (preheater or prelubrication) Start/stop sequences with selectable no. of start attempts Fuel

More information

EnCell Battery Cell Monitor

EnCell Battery Cell Monitor EnCell Battery Cell Monitor Instruction Manual Model RCM15S12 NERC Compliant YO R U H T PA TO Z O R E W O D N M I T E enchargepowersystems.com sales@enchargepowersystems.com (888) 407.5040 Contents 1 Warnings,

More information

E101 - Strain Gauge Transducer Display Module. Contents

E101 - Strain Gauge Transducer Display Module. Contents E101 - Strain Gauge Transducer Display Module Contents Torque Transducer Display Interface: TSE3249R Strain Gauge Transducer Display Interface [E101] Operating Guide: TSE2097V (Includes Introduction, Description

More information

NMEA2000 to Modbus Gateway Part No User Manual

NMEA2000 to Modbus Gateway Part No User Manual NMEA2000 to Modbus Gateway Part No. 3155 User Manual Revision 1.21 Offshore Systems UK Ltd Unit 11 Milton Business Centre Wick Drive, New Milton, BH25 6RH, UK www.osukl.com Page 2 of 55 Contents 1 Introduction...

More information

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT DKG-210 UNIVERSAL INTERNET GATEWAY UNIT AC & DC SUPPLY VERSIONS DESCRIPTION The DKG-210 is designed for internet monitoring and control of industrial devices using different protocols through the RAINBOW

More information

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter 5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL 33309 3211 Fruitland Ave Los Angeles, CA 90058 SST7000 SST7100 Speed Switch / Transmitter Installation and Operation Manual Rev. C P/N145F-13112 PCO 00009270

More information

SKF Multilog On-line System IMx-8. 24/7 condition monitoring to improve machine reliability

SKF Multilog On-line System IMx-8. 24/7 condition monitoring to improve machine reliability SKF Multilog On-line System IMx-8 24/7 condition monitoring to improve machine reliability SKF Multilog On-line System IMx-8 The SKF Multilog On-line System IMx-8, is a powerful solution for condition

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

UNIVERSAL CURRENT CONVERTER

UNIVERSAL CURRENT CONVERTER UNIVERSAL CURRENT / VOLTAGE CONVERTER AC/DC Current / Voltage Analyzer The is the first CURRENT / VOLTAGE CONVERTER & ANALYZER ALL IN ONE - of the market. It allow you to connect all isolated current sensors.

More information

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

MOD-IO9 Modbus Input / Output Modules, Wall Mounted Product sheet MOD3.9 Type MOD-IO9 MOD-IO9 Modbus Input / Output Modules, Wall Mounted MOD-IO9 and MOD-IO9-AI have been designed to be a compact wall mounted Modbus RTU input and output module. The module

More information

iswitch imotor Compact QR

iswitch imotor Compact QR PRODUCT DATA SHEET iswitch imotor Compact QR Features: Compact design Fit for purpose Suitable for 2 feeder switches Quick Release for manual operation High operation torque Operation monitoring (max.

More information

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel Manual# 1006495 Installation Manual 200E Series DCU 210E/208E Engine Panel RP 210E/220E Remote Panel Installation Manual for the Marine Pro 200E Series ~~~ DCU 210E/208E Diesel Engine Control Unit RP 210E/220E

More information

General information Engineering with Programming package. Display with display

General information Engineering with Programming package. Display with display Datasheet SIPLUS S7-1200 CPU 1212C AC/DC/RLY -40... +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7212-1BE31-0XB0. COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 8 DI 24V DC 6 DO RELAY 2A 2 AI 0-10V DC, POWER

More information

IS35 Color Display. User Manual ENGLISH. simrad-yachting.com

IS35 Color Display. User Manual ENGLISH. simrad-yachting.com IS35 Color Display User Manual ENGLISH simrad-yachting.com Preface Navico is continuously improving this product, therefore we retain the right to make changes to the product at any time which may not

More information

Quick Installation Guide

Quick Installation Guide Manual# 1100340 Quick Installation Guide RIO 412 Exhaust Temp. Monitor Quick Installation Guide RIO 412 Exhaust Temperature Monitor ~~~ Printed November 2016 Revision 3 Revised Installation www.auto-maskin.com

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

Electronic SD1, AS 8, ASR 14, ASR 20

Electronic SD1, AS 8, ASR 14, ASR 20 Electronic SD1, AS 8, ASR 14, ASR 20 2 Electronic SD1, AS 8, ASR 14, ASR 20 Contents Page List of contents..................................................... 3 Function and characteristics.........................

More information

APP 700 Technical Specification

APP 700 Technical Specification Issued: 12/12 Supersedes: 4/12 Description The APP 700 hardware series are especially designed for waste and clean water systems, both in construction and functionality. The RTUs¹ are developed to meet

More information

Technical Manual Nova: Cabinet Security Management System (CSMS)

Technical Manual Nova: Cabinet Security Management System (CSMS) Technical Manual Nova: Cabinet Security Management System (CSMS) KP_nova_TM_160501_EN 1 Publication May, 2016, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com/nova

More information

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3 INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page

More information

Temperature controller Ducted systems

Temperature controller Ducted systems 2 725 Temperature controller Ducted systems Standard model without zoning functions RRV851 Multifunctional controller used for central control of ducted HVAC systems in combination with a QAX850 master

More information

iologik E1200H Series

iologik E1200H Series iologik E1200H Series Ethernet remote I/O for offshore wind power applications Features and Benefits User-definable Modbus TCP Slave addressing 2-port Ethernet switch for daisy-chain topologies Active

More information

Digital Dash I/O Adapter Configuration

Digital Dash I/O Adapter Configuration Digital Dash I/O Adapter Configuration The I/O Adapter adds ten inputs/outputs to the 7 digital dash. These inputs and outputs can then be configured as gauges or switches, and data logged locally through

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information

Faults on the system Proximity switch connection technology:

Faults on the system Proximity switch connection technology: Speed monitor for connection to a base unit from the PNOZmulti modular safety system Approvals Unit features Monitoring of 2 independent axes Connection of 2 incremental encoders or 4 proximity switches

More information

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS Characteristics battery control module - 24..28.8 V DC - 24 V - 40 A - for regulated SMPS Main Range of product Product or component type Input voltage Output voltage Maximum output current Complementary

More information

PTC/PT100 board 2.0 Option

PTC/PT100 board 2.0 Option PTC/PT100 board 2.0 Option Instruction Manual - English PTC/PT100 board 2.0 Option Instruction Manual - English Document number: 01-3873-01 Edition: r1 Date of release: 2006-10-30 Copyright Emotron AB

More information

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, AC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA

More information

Quick Start Guide MC-III TM Flow Analyzer

Quick Start Guide MC-III TM Flow Analyzer Quick Start Guide MC-III TM Flow Analyzer A Quick Reference on Mounting, Wiring, & Configuring the MC-III EXP or WP Flow Analyzer For complete instructions, see MC-III EXP User Manual, Part No. 9A-50165003

More information

CSI 6300 SIS Overview

CSI 6300 SIS Overview Overview The Digital Overspeed Protection System is TÜV - certified according to IEC 61508:2010 and provides speed measurement and detection of rotational direction for rotating machines such as turbines,

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/RLY, ONBOARD I/O: 8 DI 24V DC; 6 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Product

More information

M2500 Engine Controller Configuration Manual

M2500 Engine Controller Configuration Manual M2500 Engine Controller Configuration Manual Revision: 08-04-2011 Page 1 Contents 1 Preface... 4 2 Configuration from front panel... 5 2.1 Engine Controller Configuration... 6 2.1.1 RPM settings... 6 2.1.2

More information

CANBUS Connector Rx and Tx LED to indicate that communication is active Closed circuit terminal (Term) LAN serial port connector

CANBUS Connector Rx and Tx LED to indicate that communication is active Closed circuit terminal (Term) LAN serial port connector 4.4 IPEX60D 4.4.1 Description of the connections Connector Description Connector for 24Vac/dc power supply Analogue inputs (Pb1 - Pb5, PbC) Potential free digital inputs (DI1 - DI3, DIC) Additional power

More information

SM9000. Magnetic-inductive flow meter. Made in Germany

SM9000. Magnetic-inductive flow meter. Made in Germany Made in Germany Application Application totaliser function; empty pipe detection; for industrial applications Installation connection to pipe by means of an adapter Media conductive liquids; water; hydrous

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Features and Benefits. Certifications

Features and Benefits. Certifications MGate 5111 Series 1-port Modbus/PROFINET/EtherNet/IP to PROFIBUS slave gateways Features and Benefits Protocol conversion between Modbus, PROFINET, EtherNet/IP, and PROFIBUS Supports PROFIBUS DP V0 slave

More information

Environdata FA ma Converter Guide

Environdata FA ma Converter Guide FA12 4 20 ma Converter Guide REV 14 th July 2015 Material in this Handbook is copyright. All rights reserved by the publishers. Weather Stations Pty. Ltd., 42-44 Percy Street, Warwick, Queensland, AUSTRALIA,

More information

Control D. Controller Module for Proportional Valve Control. Installation Manual

Control D. Controller Module for Proportional Valve Control. Installation Manual Control D Controller Module Table of Contents Control D 1 1.1 1.2 1.3 1.3.1 1.3.2 1.4 2 3 4 5 5.1 5.2 5.3 6 7 8 Description 3 How To Order 3 Operating Elements 3 Adjustment 4 Operation 4 Auto-adapt 4 Operating

More information

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, AC/DC/RLY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 75 KB Display with

More information

Submittal Data Sheet WAGO Node for itm

Submittal Data Sheet WAGO Node for itm The WAGO Node integrates ancillary equipment into the Intelligent Touch Manager (itm) DCM601A71 with the use of DI, DO, AI and AO signals. It provides monitoring and control of non-daikin equipment via

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, AC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA

More information

J2K100 J1939 to NMEA 2000 Gateway. User s Manual

J2K100 J1939 to NMEA 2000 Gateway. User s Manual J2K100 to NMEA 2000 Gateway User s Manual Revision 1.3 Warning: Improper installation of the Maretron J2K100 may prevent existing engine accessories (i.e., engine gauge displays, key switches, throttle

More information

- NLS NAVIGATION LIGHT CONTROL

- NLS NAVIGATION LIGHT CONTROL Technical documentation - NLS 3000 - NAVIGATION LIGHT CONTROL For use on seagoing vessels Change status Version Date Author Checked Remark 0.1 07.08.2008 STO HN 1. Edition 0.2 29.09.2010 STO TK Changes

More information

TM221ME32TK controller M IO transistor PNP Ethernet

TM221ME32TK controller M IO transistor PNP Ethernet Product data sheet Characteristics TM221ME32TK controller M221 32 IO transistor PNP Ethernet Complementary Main Discrete I/O number 32 Number of I/O expansion module Supply voltage limits Inrush current

More information

DEEP SEA ELECTRONICS PLC DSE103 MK II Speed Switch Operators Manual

DEEP SEA ELECTRONICS PLC DSE103 MK II Speed Switch Operators Manual DEEP SEA ELECTRONICS PLC DSE103 MK II Speed Switch Operators Manual Document number 057-135 Author : Paul Gibbons DSE103 MKII Operator Manual Issue 1 Deep Sea Electronics Plc Highfield House Hunmanby North

More information

OCEANIC SYSTEMS NMEA2000 AC MODBUS GATWAY Part Numbers: 3155 USER MANUAL

OCEANIC SYSTEMS NMEA2000 AC MODBUS GATWAY Part Numbers: 3155 USER MANUAL OCEANIC SYSTEMS NMEA2000 AC MODBUS GATWAY Part Numbers: 3155 USER MANUAL Document revision 1.21 1 Introduction...3 1.1 Product Features...3 2 Installation...4 2.1 Unpacking the box...4 2.2 Choosing the

More information

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34) is dedicated for reliable monitoring of lubrication, hydraulic and insulation oils as well as diesel fuel. In addition to highly accurate measurement of water activity (a w ) and temperature (T), calculates

More information

Processor ATP1. Product Sheet

Processor ATP1. Product Sheet Processor ATP1 Product Sheet Overview A whole step forward in instrument performance Use any mixture of existing (B&G) and new (A+T) displays Can use existing Fatnet wiring to keep upgrade costs down Ethernet

More information

TM221M16R controller M IO relay

TM221M16R controller M IO relay Product data sheet Characteristics TM221M16R controller M221 16 IO relay Complementary Main Discrete I/O number 16 Number of I/O expansion module Supply voltage limits Inrush current Power consumption

More information

Rotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track

Rotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track Electronic multiturn gear with intelligent sensing technology (IST) Integrative Technology Max. 4 programmable outputs* for the SSI version Programmable parameters include*: code type, resolution per revolution,

More information

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current Datasheet SIPLUS S7-1200 CPU 1214C DC/DC/DC -40... +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7214-1AG31-0XB0. COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

MTX-D Ethanol Content and Fuel Temperature Gauge User Manual

MTX-D Ethanol Content and Fuel Temperature Gauge User Manual MTX-D Ethanol Content and Fuel Temperature Gauge User Manual P/N 3912 kit does not include flex fuel sensor. The ECF-1 is compatible with GM P/Ns 13577429 and 13577379 1. Installation... 2 1.1 Gauge Mounting...

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information

More information

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors Ron Boe 5/15/2014 This user guide details the servo drives capabilities and physical interfaces. Users will be able to

More information

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety iologik 4000 Series Modular remote I/O I/O expansion without a backplane Supports SNMPv1/v2c Active communications with MX-AOPC UA Server Easy configuration with Modular ioadmin utility Friendly configuration

More information

Communication & Networking

Communication & Networking MicroSmart Master Module Capable of Connecting 62 Slaves Compliance with Ver. 2.1 specifi cations Digital and analog slaves can be connected. Configuration and slave monitoring can be done using LED indicators

More information

The GF-2 is able to measure G-forces even if the instrument is not mounted exactly on the vertical axis of the aircraft.

The GF-2 is able to measure G-forces even if the instrument is not mounted exactly on the vertical axis of the aircraft. GF-2 +-10g Tilt Compensated dual range aviation G-force meter Operating Manual English 1.00 Introduction The GF-2 is a 3 1/8 G-force meter capable of measuring G-forces exerted in an aircraft up to +-10g.

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 100 KB General information Firmware

More information

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging

More information