Local LCD HMI - View and force I/O, and make simple configuration changes without a computer!
|
|
- Melina Dalton
- 5 years ago
- Views:
Transcription
1 Product Data Sheet A part of the new PINNACLE family Ascent I/O Smart Distributed & Peer-to-Peer I/O Wireless, Serial, and Ethernet/Internet Modular I/O for SCADA and DCS systems cost-effective monitoring and control Distributed SCADA I/O and multi-way peer-to-peer I/O Mirroring Integrated Pump/Setpoint Control (Ascent Combo) High-speed Ethernet and RS-232/485 Serial port standard Allen-Bradley (DF1) & Modicon (Modbus) protocol support Built-in LCD HMI for local setup and system test without computer User configurable web page HMI - built in Secure AES encrypted communications Built-in non-volatile totalizers, runtime meters, and rate computation Optional internal spread spectrum radio Store & Forward Repeater operation to extend radio range Low-power and smart power management for battery backed applications 3-year warranty on parts and labor New! Ascent Smart distributed and peer-topeer I/O for monitoring and remote control applications: Expand the I/O of a PLC or RTU, and add sites to a SCADA or DCS system at very low cost Save thousands of dollars of in-plant wiring with peer-to-peer wireless, serial, or Ethernet I/O. Eliminate costly PLCs, HMIs and programming where smart I/O with a built-in web HMI will do. Supported by most PLCs, RTUs & HMIs Ascent can be used with all major PLCs, RTUs, and HMI software using Modbus TCP/IP, Modbus RTU or DF1 protocols. Peer-to to-peer I/O Mirroring - Ascent Combo and DIO modules can be linked up back-to-back (up to 8 to 1) to exchange sensor and control signals over a secure two-way wireless link, external radio, modem (via RS-232/485 serial port), or Ethernet. Ascent I/O saves thousands of dollars in wiring and conduit costs. Wireless Store & Forward Any Ascent I/O module can also serve as a repeater to extend the effective range of a wireless network. Local LCD HMI - View and force I/O, and make simple configuration changes without a computer! Web Page Configuration Ascent I/O modules come ready to run, but can be customized with a standard web browser (like Windows Internet Explorer). No special software is required on your PC or laptop. Customizable User HMI Need a simple low-cost user interface? Ascent I/O includes a simple web-page HMI to save you hundreds of dollars in PC-based software costs. Web page configuration is simple and done in just minutes without programming; just fill in the blanks. Remote Support Ascent I/O can be reconfigured and customized over a secure Ethernet or wireless link, eliminating costly field trips and improving customer support. I/O can be forced via a secure web page to facilitate remote troubleshooting. Low Power DC powered Ascent I/O can be optimized for battery-backed wireless systems with multiple power-saver modes and send-on-exception operation. Smart I/O Functions Ascent I/O includes cost-saving built-in functions that eliminate programming, simplify field installation and increase versatility: Discrete Inputs - configurable filtering & debounce - non-volatile high-speed totalizers - non-volatile runtimes - rate calculation (period or interval) Discrete Outputs - duty cycle (PWM) pulse function - synchronized flash function Universal Analog Inputs - sensor support (TC, RTD, Thermistor) - configurable filtering/averaging - configurable totalization Setpoint/Pump Control (Ascent Combo) - DO relay control for each Analog Input - Duplex pump control w/alternation Communications Bridging - Ethernet to Modbus and Generic Serial/radio (virtual serial port) - Radio to Serial Analog readings, as well as totalizers, runtimes and rates are internally scalable to engineering units. Users see actual levels, flows and temperatures. Rugged Reliability Ascent I/O has an operating temp range of -40 C to 70 C, and is backed by an industry leading 3-year factory parts and labor warranty. Copyright 2010 Industrial Control Links, Inc. All Rights Reserved Specifications subject to change.
2 Ascent I/O Modules in a SCADA or DCS System Internet Ethernet Router HMI Computer Ethernet Repeater SCADA PLC RS-232 RS-485 Modbus or DF1 HMI Terminal Modbus or DF1 Serial I/O Ascent I/O modules have independent Ethernet, Serial (RS-232 and RS-485) and internal radio (option) communications ports. The ports may be used simultaneously. For example, a local Modbus HMI terminal can be connected locally to an I/O module to show levels and flows on the door of the panel housing an Ascent module, while an HMI computer or PLC is talking to the Ascent module over an Ethernet or wireless link. To extend the effective range of a wireless network, Ascent modules can act as intelligent repeaters, using either the internal radios, or external radios connected to the serial port. Ascent modules can also bridge communications between ports. In the diagram above, an HMI computer or SCADA PLC can talk to Modbus (serial) I/O modules via an Ethernet or wireless connection, or both, saving the cost of additional radios. Bridging is supported from Ethernet to serial, Ethernet to wireless, and serial to wireless. Ascent I/O Modules Mirroring I/O over Ethernet, the Internet, or Wireless Link Ascent I/O Combo and DIO modules can also be used in a peer-to-peer or mirror-mode configuration where 1 to 8 modules pass I/O information to a single Ascent module. Analog and Discrete inputs are repeated or mirrored as Analog and Discrete Outputs in both directions (2-way). In addition to I/O levels, all tag names, units, etc. as well as associated totalizer, rate and runtime measurements are available for display on the local LCD HMIs or by communications at either ends of the links. Mirroring works over Ethernet, the Internet, a wireless link, or via external modems or radios connected to the Ascent module serial ports. One or more PC computers can access local web HMI pages in any of the Ascent modules See all I/O information with the built-in web HMI! Ethernet LAN or the Internet I/O and Repeater Mirroring over an Ethernet network or the Internet Mirroring over a Wireless Network (with one node as a Repeater)
3 Combo Ascent Combo a symmetrical mixture of analog and discrete I/O; ideal for peer-to-peer mirrored I/O as well as distributed I/O applications. In addition, the Ascent Combo module has setpoint control, duplex pump control and alarming capabilities, and the Universal Inputs may be internally routed to the analog outputs to function as up to 8 configurable signal conditioners/transmitters. 8 Universal Inputs I are individually soft configurable through the builtin LCD or web page HMI; no switches or jumpers. Each input accepts standard process signals (ma, mv or V), measures resistance, and reads thermocouples, thermistors or RTD temperature sensors. Conversion speed and averaging are configurable on every input to optimize response times and noise rejection. Each input can be scaled to engineering units. 8 Analog Outputs provide high-resolution 20mA outputs, or provide a voltage output when used with an external resistor. An internal 24v loop supply is independent of the supply voltage. 10 Discrete Inputs rugged optically isolated inputs available in 12-24v or v configurations. Each input includes its own nonvolatile 32-bit totalizers and runtime accumulators, for keeping track of total flow or machine cycles, and motor and pump runtimes. In addition, pulse rates are calculated on each input, either by measuring the number of pulses over time period, or measuring the interval between pulses (Rate = 1/Time). The method used depends on the input frequency range and the desired update rate and measurement resolution. All measurements can be scaled to engineering, offloading calculations from a host PLC. This provides a meaningful user friendly display on the local LCD HMI and built-in web page HMI. 10 Discrete Outputs provide relay dry contacts with programmable flashing, precision one-shot pulse and PWM control. Ascent Combo I/O Module Specifications Analog Inputs I 8 Resolution 16-bit (24-bit internal) Input/Sensor s: 20mA, 0 to 2 Volts, +/-250 mv, Ohms, Thermocouple ( J, K, T, E, R, S, B, N) Thermistor (10K, II & III), RTD 2 and 3-wire (10,100, 1K ohm) note: 3-wire RTDs require 2 inputs each Measurement Averaging Individually configurable by input; 1, 2, 4, 8, 16, 32 samples, boxcar technique Conversion Speed User configurable; 7.5 to 4000 samples per second, per 8 inputs Input Functions (each Input) Accumulator (integrate/totalize input with 1 to 255 sec sampling interval) Analog Outputs 8 Resolution/ 16-bit, 0/4 to 20mA (voltage output with external resistor) Discrete Inputs I 10 Optically Isolated Input Ranges Order as 12/24V (up to 30Vdc/Vac), or 120V/240V (up to 260Vac) Input Conditioning Programmable Filtering/Delay (0 to 65,535mS) Runtime 1 32-bit non-volatile timer per input, configurable to read in seconds, tenths of minutes and tenths of hours Totalizers 1 32-bit non-volatile high-speed counter per input, (5KHz Max.) Rate Measurement Dual mode (Sample Period or 1/frequency) 1 to 255 second sample period, 0 to 65,535mS (1/F measurement technique) Discrete Outputs 10 Relay contact, 3A max. per output Output Functions (each output) Flash (synchronized with other outputs) Pulse (one-shot) 1 to 65,535mS, PWM - programmable On/Off times 1 to 65,535mS each
4 UI-32 Ascent UI-32 providing 32 Universal Analog Inputs. Each of the inputs are individually soft configurable through the built-in LCD or web page HMI; no switches or jumpers. Each input can be scaled to engineering units, offloading calculations from a host PLC. This provides a meaningful user friendly display on the local LCD HMI and built-in web page HMI. 32 Universal Inputs, individually soft configurable through the built-in LCD or web page HMI - no switches or jumpers. Each input may be configured to accept standard process signals (ma, mv or V), resistance, or thermocouple, thermistor or RTD temperature sensor. Conversion speed and built-in box car averaging are also configurable by channel in order to optimize response times and noise rejection. This also helps to offload processing overhead from PLC or DCS systems. Each group of eight inputs can be sampled up to 4000 times per second for an aggregate maximum sampling rate of 16,000 readings per second across all 32 inputs! The high conversion speed combined with a high-speed Ethernet interface makes these modules ideal for large distributed control and monitoring systems. The ability to talk multiple industry standard protocols makes these modules a low-cost alternative to expensive PLC and DCS system analog input modules. Ascent UI-32 Universal input Module Specifications Analog Inputs Quantity 32 Resolution 16-bit (24-bit internal) Input/Sensor s: 20mA, 0 to 2 Volts, +/-250 mv, Ohms, Thermocouple ( J, K, T, E, R, S, B, N) Thermistor (10K, II & III), RTD 2 and 3-wire (10,100, 1K ohm) note: 3-wire RTDs require 2 inputs each Measurement Averaging Individually configurable by input; 1, 2, 4, 8, 16, 32 samples, boxcar technique Conversion Speed User configurable; 7.5 to 4000 samples per second, per 8 inputs Input Functions (each Input) Accumulator (integrate/totalize input with 1 to 255 sec sampling interval)
5 DIO - 22/22 Ascent DIO-22/22 a symmetrical mixture of discrete inputs and outputs; ideal for peer-to-peer mirrored I/O as well as distributed I/O applications. 22 Discrete Inputs rugged optically isolated inputs available in 12-24v or v configurations. Each input includes its own nonvolatile 32-bit totalizer for keeping track of total flow or machine cycles, and a non-volatile 32-bit runtime meter, to keep track of motor and pump runtimes. In addition, pulse rates are calculated on each input, either by measuring the number of pulses over time period, or measuring the interval between pulses (Rate = 1/Time). The method used depends on the input frequency range and the desired update rate and measurement resolution. All measurements can be scaled to engineering, offloading calculations from a host PLC. This provides a meaningful user friendly display on the local LCD HMI and built-in web page HMI. 22 Discrete Outputs provide relay dry contacts with programmable flashing, precision one-shot pulse and PWM control functions. The flashing function provides a synchronized flash output whose time period is programmable, but common to all flashing outputs. This is used primarily to operate flashing alarm indicators. Every output also supports a one-shot pulse function; each time the channel is activated, the output turns on for a precision length of time, and then turns off automatically. This type of operation is frequently used with motorized actuators to move them a prescribed distance, independent of communications latency. The outputs also support PWM (Pulse Width Modulated) operation, where the output toggles on and off for a precision period of time, and where each channels on and off time can be set independently. This operation is used for heater and metering pump controls, frequently as part of some closed loop control system. Ascent DIO 22/22 Input/Output Module Specifications Discrete Inputs 22 Optically Isolated Input Ranges Order as 12/24V (up to 30Vdc/Vac), or 120V/240V (up to 260Vac) Input Conditioning Programmable Filtering/Delay (0 to 65,535mS) Runtime 1 32-bit non-volatile timer per input, configurable to read in seconds, tenths of minutes and tenths of hours Totalizers 1 32-bit non-volatile high-speed counter per input, (5KHz Max.) Rate Measurement Dual mode (Sample Period or 1/frequency) 1 to 255 second sample period 0 to 65,535mS (1/F measurement technique) Discrete Outputs 22 Relay contact, 3A max. per output Output Functions (each output) Flash (synchronized with other outputs) Pulse (one-shot) 1 to 65,535mS, PWM - programmable On/Off times 1 to 65,535mS each
6 DI - 44 Ascent DI-44 a Discrete Input module that provides an economical means of monitoring a large number of Discrete Input sensors at a location. Local processing offloads most realtime response constraints of communications without missing a single transition or accurately measuring rates and runtimes. 44 Discrete Inputs rugged optically isolated inputs available in 12-24v or v configurations. Each input includes its own nonvolatile 32-bit totalizer for keeping track of total flow or machine cycles, and a non-volatile 32-bit runtime meter, to keep track of motor and pump runtimes. In addition, pulse rates are calculated on each input, either by measuring the number of pulses over time period, or measuring the interval between pulses (Rate = 1/Time). The method used depends on the input frequency range and the desired update rate and measurement resolution. All measurements can be scaled to engineering, offloading calculations from a host PLC. This provides a meaningful user friendly display on the local LCD HMI and built-in web page HMI. Ascent DI-44 Input Module Specifications Discrete Inputs 44 Optically Isolated Input Ranges Order as 12/24V (up to 30Vdc/Vac), or 120V/240V (up to 260Vac) Input Conditioning Programmable Filtering/Delay (0 to 65,535mS) Runtime 1 32-bit non-volatile timer per input, configurable to read in seconds, tenths of minutes and tenths of hours Totalizers 1 32-bit non-volatile high-speed counter per input, (5KHz Max.) Rate Measurement Dual mode (Sample Period or 1/frequency) 1 to 255 second sample period 0 to 65,535mS (1/F measurement technique)
7 Ascent I/O Common Specifications Communications, Networking & HMI Ethernet Protocol support Security 10 BaseT Modbus TCP (Slave), Modbus UDP (Slave), HTTP, ARP, SDX (ICL), Serial Port Forwarding to serial port or internal radio 128-bit AES encryption using SDX protocol Separate passwords on user and configuration web pages. Serial Port Data rate Protocol support Security RS-232 and RS baud to 115K baud Modbus RTU Slave (Modicon), DF1 (Allen-Bradley), SDX (ICL), Store & Forward (Modbus & SDX) 128-bit AES encryption Internal Radio (optional) Radio type Freewave MDS Digi/Maxstream Modes of Operation: Output power Data rate Antenna Connection: Protocol support Security Choice of 3 radios; Digi (Xtend), Freewave (MR2), or MDS (Transnet) 902MHz to 928MHz Spread Spectrum, frequency hopping, (plus MESH networking with Digi Xtend radio) Sensitivity: -108dBm (BER 10-6 ), 32-bit CRC, point to multipoint, network diagnostics, FGR-115 compatible Sensitivity: -108dBm (BER 10 ), 16-bit CRC, point to multipoint, network diagnostics, Transnet compatible -6 Sensitivity: baud, baud, point to multipoint & peer to peer, DigiMesh Point to multipoint (all models), peer to peerand mesh (Digi Xtend only) 1Watt maximum (user settable down to 100mW) 115K or 9600 baud, over the air Reverse polarity SMA Modbus RTU Slave (Modicon), DF1 (Allen-Bradley), SDX (ICL), Store & Forward (Modbus & SDX) 256-bit AES encryption on all over-the-air messaging, plus128-bit AES encryption on SDX messages Local HMI Web HMI General Watchdog Timers Terminal Blocks Mounting Dimensions Environment Power Warranty Display:122x32 Graphic LCD w/backlight (4 lines x 20 characters max. in character mode) Input: 5 Axis navigation Switch plus Escape pushbutton switch HTML web pages; separate security access for configuration and users Communications (individually configurable by port). Resets outputs to individually user defined states. CPU Ensures sanity of internal processor operation Removable, 3.5mm (0.138 ), 12 to 22AWG, 15A/contact maximum 35mm. DIN rail or panel mount 6.2 W x 6.2 H x 2.4 D (includes terminal blocks and elevation off panel on DIN rail) - 40 o F(- 40 o C) to 158 o F (70 o C), 5%RH to 95% RH, non-condensing 10 to 30Vdc Power consumption varies by module type, active outputs, and radio operation (internal radio option). With Ethernet OFF; 30mA 12Vdc (Dos and AOs off), 400mA max. (radio transmit, maximum AOs/DOs ON) Ethernet ON (without radio): 100mA 12Vdc (Dos and AOs off), 500mA 12Vdc (AOs/DOs ON) 3 years, factory parts and labor " 6.2" 6.2"
8 For the perfect complement to the Ascent I/O modules check out the new Pinnacle family of programmable SCADA controllers. Everest 300MHz 32-bit CPU, Real Time Clock/Calendar 128MB RAM, 512MB Flash Disk (expandable to 2TB) 1 10/100 Ethernet 4 USB 5 Serial Ports (4 x RS-232, 1 x RS-232/RS-485) Optional internal radio and telephone modem Base I/O: 8 Universal Analog inputs 1 Analog input / UPS Battery Input 4 Analog Outputs 4 Digital I/O (Low voltage & high-speed counters) 2 High-speed Pulse/Magnetic Pickup Inputs 20 Digital Inputs, Optically Isolated 12 Digital Outputs, Relay Shasta 300MHz 32-bit CPU, Real Time Clock/Calendar 128MB RAM, 512MB Flash Disk (expandable to 2TB) 1 10/100 Ethernet 2 USB 3 Serial Ports (2 x RS-232, 1 x RS-232/RS-485) Optional internal radio and telephone modem Base I/O: 8 Universal Analog inputs 1 Analog input / UPS Battery Input 2 Analog Outputs 2 Digital I/O, Low voltage and Hgh-speed counters 1 High-speed Pulse/Magnetic Pickup Inputs 16 Digital Inputs, Optically Isolated 6 Digital Outputs, Relay Rubicon 300MHz 32-bit CPU, Real Time Clock/Calendar 128MB RAM, 512MB Flash Disk (expandable to 2TB) 1 10/100 Ethernet 2 USB 3 Serial Ports (2 x RS-232, 1 x RS-232/RS-485) Lassen Base I/O: 4 Universal Analog inputs 2 Analog Outputs 1 High-speed Pulse/Magnetic Pickup Inputs 20 Digital Inputs, Optically Isolated 10 Digital Outputs, Relay 300MHz 32-bit CPU, Real Time Clock/Calendar 128MB RAM, 512MB Flash Disk (expandable to 2TB) 1 10/100 Ethernet 2 USB Base I/O: 2 Universal Analog inputs 1 Analog input 2 Analog Outputs 6 Digital Inputs, Low voltage and Hgh-speed counters 6 Digital I/O, Low voltage 1 High-speed Pulse/Magnetic Pickup Inputs Represented by: Industrial Control Links, Inc. Tel:
SCADAPack Smart RTU
SCADAPack 330 334 Smart RTU 1 Built on the proven SCADAPack 300 platform, the SCADAPack 330 and 334 feature high-performance 32-bit processing, highspeed LAN, serial and USB communications, integrated
More information5OOO Series. Expansion & Communication Modules. Product Selection Guide. Expansion. Communication CONTROL MICROSYSTEMS
CONTROL MICROSYSTEMS Product Selection Guide 5OOO Series Expansion & Communication Modules Expansion Analog input module: 5 variations Analog output module: 5 variations Digital input/output relay module:
More informationINTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx
INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROLS, INC. PCMNET Users Manual Revised 2/4/2005 2003-2005 Integrated Systems and Control. Inc. PO Box
More informationiologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection
iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch User-definable Modbus/TCP Slave addressing Supports EtherNet/IP* adapter mode Supports RESTful API for IIoT applications 2-port Ethernet
More informationSCADAPack. I/O Expansion & Communication Modules
SCADAPack I/O Expansion & Communication Modules 1 Welcome to the SCADAPack family of I/O Expansion and Communication modules, providing flexible I/O and telemetry options. With the addition of I/O Expansion
More informationFeatures and Benefits. Certifications
iologik E2200 Series Smart Ethernet remote I/O with Click&Go Logic Features and Benefits Front-end intelligence with patented Click&Go control logic, up to 24 rules Active communication with MX-AOPC UA
More informationSCADAPack 32. Smart RTU
SCADAPack 32 Smart RTU 1 Compared to the SCADAPack 300 platform, the SCADAPack 32 is a higher performance Smart RTU built to meet the demands of larger applications including support for up to 10 gas flow
More informationFeatures. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System
Features 10/100Mbps Ethernet full duplex Auto Negotiation Support C++/C Modbus/TCP drivers and OPC server Support configuration via built-in Web browsing, (HTML), Device Finder and I/O configuration utilities
More information2500 Series Slice I/O
2500 Series Slice I/O INSTALLATION AND OPERATION GUIDE Version 1.3 2500 Series Slice I/O Installation and Operation Guide - V1.1 1 Copyright 2013 Control Technology Inc. All rights reserved. This manual
More informationiologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O
iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Active communication with patented MX-AOPC UA Server and Active OPC Server 2 switched Ethernet ports for daisy-chain topologies Easy
More informationiologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence
iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Active communication with patented MX-AOPC UA Server and Active OPC server Smart alarm management with email, SNMP traps, TCP, UDP Save
More informationTrident and Trident X2 Digital Process and Temperature Panel Meter
Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products
More informationVersaMax Micro and Nano Technical Product Presentation
VersaMax Nano VersaMax Micro VersaMax Micro and Nano Technical Product Presentation Outline Introduction VersaMax Micro and Nano Product Strategy Future Products Product Description VersaMax Nano VersaMax
More informationDupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications
Dupline Data Logger Types G 800 006, G 800 106 Product Description Programmable channel generator with optional built-in GSM Modem Event and time based data logging functions for digital, analog and counter
More informationZ-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS
e & Designed GSM / GPRS ETHERNET SMTP HTTP MODBUS TCP-IP USB MODBUS RTU THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS www.seneca.it taly 100% ad I in GSM/GPRS DATALOGGER WITH BUILT-IN
More informationAndover ContinuumTM Infinet II
Andover ContinuumTM Infinet II i2920 System Controllers The Andover Continuum Infinet II i2920 System Controller is designed to meet the needs of your most demanding control and monitoring applications
More informationRS-485 I/O Modules: ADAM-4000
RS-485 I/O Modules: ADAM-4000 23 ADAM-4000 Series Overview ADAM-4000 Series Remote Data Acquisition and Control Modules Overview 23-2 and Controller Module Selection Guide 23-4 I/O Module Selection Guide
More informationReliable, Easy to Use SCADA Solutions: Water/Wastewater Oil & Gas Electric Power. Industrial Control Links, Inc.
Reliable, Easy to Use SCADA Solutions: Water/Wastewater Oil & Gas Electric Power Industrial Control Links, Inc. For over 26 years, Industrial Control Links, Inc. has been developing innovative products
More information12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)
4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type
More informationI-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS
I-7520 RS-232 to RS-485 Converter I-7510 RS-485 Repeater RS-232 RS-485 I-7000 SERIES Common Specifications Isolation voltage: 3000VDC Speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115000 Dual watchdog
More informationIntech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.
Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-RO4 Installation Guide. The 2300 series stations are designed to
More informationSelf-Powered Wireless Instrumentation
Self-Powered Wireless Instrumentation Accutech Rapid deploy wireless instrumentation solutions for telemetry and remote SCADA Cost-Effective Solutions for Challenging Applications 03 Knowledge of your
More informationSCADAPack ES. Smart RTU
Smart RTU 1 Meeting the demands for high-speed distributed control and automation systems, Schneider Electric offers the SCADAPack ES as an advanced Smart RTU. Our highest performance Smart RTU built on
More informationSCADAPack ES. Smart RTU
Smart RTU 1 Meeting the demands for high-speed distributed control and automation systems, Schneider Electric offers the as an advanced Smart RTU. Our highest performance Smart RTU built on a native DNP3
More informationLAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.
Description LAUREL ELECTRONICS, INC. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets Features Frequencies up to 1 MHz Totals stored in non-volatile
More informationLAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.
Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals
More informationICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions
ICP DAS 2015 M2M WLAN Wireless Solutions Industrial Computer Industrial Product Data Computer Acquisition Product System Data Acquisition System PAC WLAN Wireless Solutions Wi-Fi Products WLAN Converter
More informationIntech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.
Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-A8VI Installation Guide. The 2300 series stations are designed to
More informationSCADAPack 350E 357E. Smart Remote Terminal Unit
SCADAPack 350E 357E Smart Remote Terminal Unit 1 The SCADAPack 300E Smart RTU is a platform built on a 32-bit processor and fitted with a 12-30 Vdc supply, various communication links and a wide range
More informationSCADAPack 312E 313E 314E
Smart Remote Terminal Units The 300E Smart RTU is a platform built on a 32-bit processor and fitted with a 12...30 Vdc supply, various communication links and a wide range of analog and digital I/O that
More informationWith a digital input we can read two states, a high or low. A switch can be open or closed.
Page 1 of 6 PRODUCT INFORMATION B&B ELECTRONICS Data Acquisition Basics Data Acquisition hardware devices provide an interface between electrical signals a computer can read or can output to control things
More informationLAUREL ELECTRONICS, INC.
Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals
More informationADAM-6200 Series. Feature. Transition and Vision on Remote DAQ Device 19-13
ADAM-6200 Series Feature DI/O LED Indication Flexible user-defined Modbus address 19 20 21 DAQ Boards Signal Conditioning Industrial USB I/O Modules22 Transition and Vision on Remote DAQ Device In 2002,
More informationG303 RIO (REMOTE I/O) AND LOW END RTU
G3 TECHNOLOGIES, INC. G303 RIO (REMOTE I/O) AND LOW END RTU USER DOCUMENTATION / FUNCTIONAL SPEC. Introduction: The G303 is one of several RIO (Remote I/O) products from G3 Technologies designed to fill
More informationiothinx 4500 Series (45MR) Modules
iothinx 4500 Series (45MR) Modules Modules for iothinx 4500 Series Feature and Benefits Easy tool-free installation and removal Built-in LED indicators for IO channels Wide operating temperature range:
More information1500ct Pump Controller
Quality Control & Integration, Inc. Control, Instrumentation, Telemetry, SCADA, and Automation Systems 1500ct Pump Controller Dynamic Solutions for greater control and true dynamic I/O, color, touch screen
More information1500ct Pump Controller
Quality Control & Integration, Inc. Control, Instrumentation, Telemetry, SCADA, and Automation Systems 1500ct Pump Controller Dynamic Solutions for greater control and true dynamic I/O, color, touch screen
More informationiologik E1200H Series
iologik E1200H Series Ethernet remote I/O for offshore wind power applications Features and Benefits User-definable Modbus TCP Slave addressing 2-port Ethernet switch for daisy-chain topologies Active
More informationSCADAPack 350E 357E. Smart Remote Terminal Units. Distributed by Relevant Solutions relevantsolutions.com
Smart Remote Terminal Units The SCDPack 300E Smart RTU is a platform built on a 32-bit processor and fitted with a 12...30 Vdc supply, various communication links and a wide range of analog and digital
More informationXYR3000 Wireless Family of Multiplexer I/O, Gateways and Extensions Specifications and Technical Data Doc 34-XY-03-33, Version 1.0
XYR3000 Wireless Family of Multiplexer I/O, Gateways and Extensions Specifications and Technical Data Doc 34-XY-03-33, Version 1.0 Table of Contents Product Introduction Summary... 2 Field Mountable Multiplexer
More informationAndover ContinuumTM. b3850 Series Terminal Controllers
TM b3850 Series Terminal Controllers The TM b3850 series controllers are native BACnet controllers that communicate on an RS-485 field bus as Master devices using the MS/TP BACnet protocol. 02 Features
More informationGreenEye Monitor Specifications
Number of Channels Power Monitoring Section 32 (expansion available in the future) Measurement POWER: True (or Real) Power using high speed volt and current sampling VOLTAGE: True RMS Accuracy Sampling
More informationiologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety
iologik 4000 Series Modular remote I/O I/O expansion without a backplane Supports SNMPv1/v2c Active communications with MX-AOPC UA Server Easy configuration with Modular ioadmin utility Friendly configuration
More informationAndover ContinuumTM Infinet II
Andover ContinuumTM Infinet II The i80 Series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. Features 0 Choose the i80 model with the
More informationMOD-MUX MODBUS TCP I/O PRODUCTS
MOD-MUX MODBUS TCP I/O PRODUCTS Catalog and Design Guide P.O.Box 24 Stanfield 3613 SOUTH AFRICA Tel: +27 (031) 7028033 Fax: +27 (031) 7028041 Email: proconel@proconel.com Web: www.proconel.com 22/09/2009
More informationModulus Selection Guide January 1, 2019 Industrial Control Links, Inc.
Modulus Selection Guide January 1, 2019 Industrial Control Links, Inc. Modulus Selection Guide Rev A13 Copyright 2019 Industrial Control Links, Inc. All Rights Reserved Supercedes all previous revisions.
More information8B SLX300 Data Acquisition System
8B SLX300 Data Acquisition System Description Dataforth s newest data acquisition system builds on the proven reliability of the SLX200 SCM5B-based system and also takes advantage of the miniature size
More informationEthernet I/O Modules: ADAM-6000
Ethernet I/O Modules: ADAM-6000 16 ADAM-6000 Series Overview ADAM-6000 Series 16-2 Peer-to-Peer Technology 16-4 Graphic Condition Logic (GCL) Technology 16-6 ADAM-6000 Selection Guide 16-8 I/O Modules
More informationNI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server
DATALOGGER NI2400/NI816/NI4866 8/16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATASHEET Rev. 08 del 08/10/2018 Redatto da R&D Approvato da MKT GENERAL 1SPECIFICATIONS NI4866 NI816 NI2400
More informationUDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS
UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 12/99 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC 1000 and UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers
More informationICP DAS. ICP DAS 2013 M2M ZigBee Wireless Solutions
2013 M2M ZigBee Wireless Solutions Industrial Computer Industrial Product Data Computer Acquisition Product System Data Acquisition System PAC New ZigBee Solutions: ZT-2000 Series Products ZigBee Wireless
More informationMicro-Modular Programmable Controller
Micro-Modular Programmable Controller Productivity2000 Features CPU with 5 communication ports OLED message display on CPU module Plenty of discrete and analog I/O modules Status displays on all discrete
More informationPD765 TRIDENT. Trident Series Process & Temperature Meters.
PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) Type 4X, NEMA 4X, IP65 Front 1/8 DIN Shallow
More informationWeb-enabled DAQ System
2016-09 EC-8631 500479 6-0001 Rev.0 01 Web-enabled DAQ System Model: TR30-G High Speed Sampling 5 ms/ai 16 points HTTP server Modbus/TCP master and slave Trigger recording FTP client and server E-mailing
More informationFEATURES DESCRIPTION FEATURES
FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs 24 Sinking or Sourcing Inputs 16 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate
More informationSCADAPack 330E 333E 334E 337E
Smart Remote Terminal Units The 300E Smart RTU is a platform built on a 32-bit processor and fitted with a 12...30 Vdc supply, various communication links and a wide range of analog and digital I/O that
More informationWHERE THE FUTURE MEETS THE PRESENT. Datascan. solo Network Based Data Acquisition System
WHERE THE FUTURE MEETS THE PRESENT Datascan solo Network Based Data Acquisition System CONTENTS INTRODUCTION 1 ANALOG INPUT/OUTPUT MODULES &3 DIGITAL INPUT/OUTPUT MODULES PRODUCT FEATURES &5 NETWORK CONTROLLERS,
More informationFeatures and Benefits. Certifications
iologik R1200 Series RS-485 remote I/O Features and Benefits Dual RS-485 remote I/O with built-in repeater Supports the installation of multidrop communications parameters Install communications parameters
More informationiologik 4000 Series (M) Modules
iologik 4000 Series (M) s Remote I/O modules Features and Benefits I/O expansion without a backplane Active communication with MX-AOPC UA Server Supports SNMP v1/v2c Easy configuration with Modular ioadmin
More informationSCADAPack 312E 313E. Smart RTUs for water
SCADAPack 312E 313E Smart RTUs for water 1 SCADAPack 312E and 313E Smart RTUs feature 32-bit processing, serial and US communications, integrated 12-30Vdc power supply, advanced power-management and a
More informationD7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES
11/17 D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES D7000 FEATURES Complete data acquisition systems. Analog and Digital I/O models available. RJ-45 Ethernet 10/100MB interface. Modbus TCP/IP Ethernet
More informationD5 SERIES WIRELESS SYSTEM
Our D5 series includes a range of radio s operate in the European free-use bands that differ in the type of interfaces and that communicate with each other directly or through repeaters. Available interfaces
More informationIntech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.
Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-RTD6 Installation Guide. The 2300 series stations are designed to
More informationVR18 FAQs - Frequently Asked Questions
VR18 FAQs - Frequently Asked Questions Q1: What is the maximum scale low and scale high values we can set in the recorder for the analog inputs and outputs? Q2: What is the maximum distance between PC
More informationLC-5 Level Controller & Flow Monitor
The Level Controller and Flow Monitor provides a fully integrated Duplex Controller supporting both analog and discrete (float switch) level detection. The unit allows collecting 'rate of flow' information
More informationReal-Time Automation Controllers (RTACs) Economical, multifunctional, compact real-time automation control
SEL-3505/3505-3 Real-Time Automation Controllers (RTACs) Economical, multifunctional, compact real-time automation control RTAC versatility facilitates easy event collection, protocol conversion, and secure
More informationWI-I/O 9 Multi I/O Units
WI-I/O 9 Multi I/O Units A transceiver is a wireless device made up of a transmitter and receiver. Since each module can manage both input and output signals, it can be used to monitor transducers and
More informationAndover ContinuumTM Infinet II
Andover ContinuumTM Infinet II i2850 Series The i2850, i2851, and i2853 controllers provide cost-effective DDC control of individual terminal units (e.g. VAV boxes, fan-powered induction units, unit ventilators,
More information900EN Series. Acromag RUN ST DIO STATUS ACT LINK DFT RST ETHERNET TB1
900EN Series EtherNet/IP or Modbus TCP/IP 0 4 5 A B 4. (.9) TB4 4 45 44 4 4 4 5 4 TB4 COM AI + AI + COM AI + AI 0+ GND DC- ANALOG IN PWR Standard model includes cage clamp terminal blocks. Optional terminals
More informationSCADAPack 530E 535E. remote Programmable Automation Controller
SCADAPack 530E 535E remote Programmable Automation Controller 1 With the SCADAPack 500E range, Schneider Electric introduces the first ever remote Programmable Automation Controller (rpac). This data sheet
More informationPD765 TRIDENT. Trident Series Process & Temperature Meters.
PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56" (14.2 mm) or 1.20" (30.5 mm) Linear or Square Root with Low-Flow Cutoff
More informationBACnet. b3810 Series Local Controllers
BACnet b380 Series Local Controllers The Andover Continuum TM b380 series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. 0 Features Choose
More informationPBSCONTROL. AMS-R4000 Modular RTU. Remote Terminal Unit
PBSCONTROL AMS-R4000 Modular RTU Remote Terminal Unit AMS-R4000 Introduction The documentation and the software included with this product are copyrighted 2017 by pbscontrol Company. AMS-4000 System is
More informationLAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description
LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process and Ratiometric Signals Features Reads process signals from ±200 mv to ±600V or ±2 ma to ±5A full scale Ratiometric mode for bridges and
More informationRemote Terminal Unit ER1000 APPLICATION FEATURES
Remote Terminal Unit ER1000 ERL with more than three decades of expertise in Power System Protection have developed state of the art Automation Solutions. The whole family of ERL s Remote Terminal Unit
More informationWE CONNECT REAL WORLD STRUCTURAL MONITORING SMART SENSORS SOFTWARE CLOUD WIRELESS INTERFACE TO THE
WE CONNECT REAL WORLD TO THE STRUCTURAL MONITORING SENSORS WIRELESS INTERFACE SOFTWARE CLOUD Rev.10 del 3/10/017 Redatto da: R&D e MKT Approvato da: CEO Smart structural WIRELESS Interface NI00 devices
More informationTemperature, Process &
Temperature, Process & 150 For Temp. Units 1/32 DIN meter 195 with 2 control outputs User Friendly, Simple to Configure High Quality i/32 i/16 i/8 Extended 5-Year Warranty Powerful Features Free Software,
More informationGreenEye Monitor. Introducing AVAILABLE IN TWO VERSIONS: FEATURES. Residential Single/Split Phase Systems. Three Phase commercial, light industrial
Introducing GreenEye Monitor AVAILABLE IN TWO VERSIONS: Residential Single/Split Phase Systems Three Phase commercial, light industrial The GreenEye Monitor (GEM) is a multi-channel energy consumption
More informationSIXNET EtherTRAK Ethernet I/O Selection Guide. SIXNET RemoteTRAK RS485 I/O Selection Guide. Ethernet og RS485 I/O oversigt.
Ethernet og RS485 I/O oversigt EtherTRAK I/O Flere varianter se oversigt RemoteTRAK I/O Flere varianter se oversigt SIXNET EtherTRAK Ethernet I/O Selection Guide I/O Count (Module w/ Base) DI AI DO AO
More informationThe new Expert Logger 400: Industry 4.0 ready!
The new Expert Logger 400: Industry 4.0 ready! NEW AND ONLY WITH US: With an OPC UA interface! Data logging Test stand automation Process monitoring At last we have the security for measurement technology
More informationSelect Family: MicroLogix 1100 or 1400 Controller
Select Family: MicroLogix 1100 or 1400 Controller 21 Select Family: MicroLogix 1100 or 1400 Controller Step 1 - Select: controller family - based on memory, I/O, added functionality, programming instructions
More informationMICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS
MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller /
More informationCROSSFIRE Ultra-Low Power Chemical Injection Pump
CROSSFIRE Ultra-Low Power Chemical Injection Pump Introduction The LCO Technologies CROSSFIRE Chemical Injection pump is an ultra-low power device that is designed to reduce chemical costs, maintenance
More informationEthernet Remote I/O Modules. OME-ET-7000/ OME-PET-7000 Series. Features
Ethernet Remote I/O Modules OMEET7000/ OMEPET7000 Series U MultiFunction Web Based Ethernet I/O Modules Models Available For Thermocouple, RTD, Analog Voltage and Current Input U BuiltIn Web Server for
More informationWarranty. Warning. Copyright. Contact Us
M-6026U-32 16-channel Universal Input and 16-channel Universal Output Version: 1.0.0 Date: Dec. 2017 Edited by Horse Chien M-6026U-32 User Manual Version 1.0.0 Dec. 2017-1 - Warranty All products manufactured
More informationTALON Network Manager- 2 & 6 Express
Technical Specification Sheet October 30, 2010 TALON Network Manager- 2 & 6 Express Description The TALON Network Manager-2 & 6 Express (TNM-2 XPR and TNM-6 XPR) is an embedded controller/server platform
More informationD1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES
D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES D1000 FEATURES Complete sensor to RS-232/RS-485 interface. 500V rms analog input isolation. 15 bit measurement resolution. Continuous self-calibration;
More informationDI-942MB. Frequency/Counter Module. Two Frequency or Pulse Waveform Inputs
Frequency/Pulse Counter Modules Periodic or Pulse Waveform Input Limit Alarms or Discrete Outputs Models DI-942MB: 2 input channels Input Two input channels: 0 to 50KHz in three selectable ranges Amplitudes
More informationNF760 Batch Controller
NF760 Batch Controller Overview The NF760 Batch Controller is suited to flow applications where precise measurement and control of batch quantities is required. Batch total, flow rate, accumulated total
More informationiologik 2500 HSPA/GPRS/WLAN Series
iologik 2500 HSPA/GPRS/WLAN Series Smart wireless remote I/O with Click&Go Plus Logic Introduction The iologik 2500 is a smart remote I/O product with unique hardware and software designs, making it an
More informationMODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE
INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 05/2009 MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES.
More informationRedundant System Redundant System P9-1-1
.. P-- Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P-- idcs-8830/idcs-8830r - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
More informationw w w. z i g s e n s e. c o m. a u
ZigSense is a line of low power wireless sensors utilizing ZigBee mesh network technology as its core communication channel. ZigSense systems contain a self healing network of wireless sensors designed
More informationsmart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...
2 content DISPLAYS... 4 smart meters... 6 panel meters... 7 field displays... 8 display types... 10 loop powered displays... 12 TRANSMITTERS & CONVERTERS... transmitters... 15 converters... 18 serial data
More informationH3 Series. Nanmac Corporation. Dual-Line 6-Digit Temperature Meter.
H3 Series Dual-Line 6-Digit Temperature Meter Temperature J, K, T, E, R, S, B, N, C Thermocouples 100 or 1000 Ω Platinum, 10 Ω Copper, 120 Ω Nickel RTDs 1 or 0.1 Resolution Averages up to 10 RTD Sensors
More informationProgrammable Logic Controllers Micro850
ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION Micro850 NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific installations
More informationEthernet I/O Modules: ADAM-6000
Ethernet I/O Modules: ADAM-6000 24 EtherNet/IP I/O Modules EtherNet/IP I/O Module Introduction 24-2 ADAM-6100 Series Selection Guide 24-3 ADAM-6117EI (New) ADAM-6118EI (New) ADAM-6150EI (New) ADAM-6160EI
More informationTC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.
LAUREL ELECTRONICS, INC. Laureate Thermocouple Panel Meter / Controller Features Factory calibrated for thermocouple types J, K, T, E, N, R, S Entire range of each thermocouple in one scale Highly accurate
More informationEurotherm advanced controllers providing solutions for simple to demanding applications...
Eurotherm advanced controllers providing solutions for simple to demanding applications......with unique levels of control and flexibility Eurotherm 2604-2704 Unique Levels of Flexibility Setpoint Programmer
More informationEthernet to Digital In ED-516. Connect, Configure, Control. ED-516 ETHERNET TO Digital IO 16 Inputs. Digital Inputs 1-8. NuDAM/ADAM Module connection
Ethernet to Digital In ED-516 ED-516 ETHERNET TO Digital IO 16 Inputs ED-516 16 Digital Inputs Monitor any input from TTL to high voltage high current industrial devices 0 to 30 Volt inputs ideal for dry/volt
More information