High Level Lift Protocol Controller Model TS0868
|
|
- Madlyn Lane
- 5 years ago
- Views:
Transcription
1 High Level Lift Protocol Controller Model TS0868 High Level Lift Protocol Controller : Model TS0868 INSTALLATION GUIDE A high level lift protocol interface for the TS0869 Intelligent Four Lift Controller enabling it to communicate with third party lift controllers. Supporting the most common lift protocols such as Otis, the TS0868 works in conjunction with Tecom s TS0890 Integration Unit and the TS0869 to create seamless lift integration. Links: CASE: This link connects the earth of the supply to the chassis. The link is not normally installed. Links: GND: This Link connects the negative of the supply to the earth lug. The link is not normally installed. J4 Power: AC power pack and battery connections. Board Configuration Switches: Settings affect board operation. J2: Serial port. Connects TS0868 to the third party lift controller. * See Dipswitch 'B' LEDs: Receive and transmit indictor LEDs. J5: Relay, reserved. Serial Port Setup: J1: Local LAN connects the TS0868 to multiple TS0869s via TS0890s. J3: Serial port. Connects TS0868 to the third party lift controller. * See Dipswitch 'B' Revised! see Protective Earthing Addendum The Leader In Innovative Security Technology High Level Lift Protocol Controller : Model TS0868 Issue I Revision I: October
2 Installation Kit: P 1 x TS0868 High Level Lift Protocol Controller 'A' Board q 1 x TS0868 High Level Lift Protocol Controller Installation Guide q 1 x TS0868 High Level Lift Protocol Controller Installation Kit q 1 x TS0304 Enclosure (optional with the TS0868B) q Connections J4: AC PWR ~ 16 Volt AC supply input. ~ (150mA maximum with no other peripheral devices BATTERY + (Red) 6.5 AHR Battery - (Black) 6.5 AHR Battery Connections J1: COMMS + (Red) Positive and negative data connection of the RS485 LAN. - (Black) This unit can be up to 1.5kms from the farthest device on the LAN, depending on the cable used. D+ (White) Recommended Belden 8723; 2 pair twisted, shielded, data D- (Green) cable. TAMP C Tamper input. Connections J5:(not currently used) NC C NO Normally Closed relay contact. Common relay contact. Normally Open relay contact. Connections J2: IG Positive and negative data connection of the RS485 LAN. D+ This unit can be up to 1.5kms from the farthest device on the LAN, D- depending on the cable used. Recommended Belden 8723; 2 pair twisted, shielded, data cable. Connections J3: DTE RS232 Port 3rd Party Interface +12 Aux. Power (50mA max.) Tx Transmit Data Rx Rx Receive Data Tx CTS Clear to Send RTS RTS Request to Send CTS GND Signal Ground GND 2 TS0868.P65 Issue I Revision I: October 1998
3 LEDs:(viewed left to right) Rx: Tx: Rx: Tx: Receiving data from J1 local LAN connection. Sending data from J1 local LAN connection. Receiving data from J3 RS232 connection or RS485 connection. Sending data from J3 RS232 connection or RS485 connection. Dip Switch Settings: ADDRESS (serial port setup) 1 - On Off 2 - Off}1200 Off}2400 On}4800 On} Off = No Parity On = Parity 4 - Off = Even Parity On = Odd Parity ABCD A - Not Used B - Off= RS485* On = RS232 C - On D - Off}OTIS Off}EPL Kone * RS485 mode only available at 1200 or 2400 baud rates. Specifications: Power Input Voltage: Volts AC Plug Pack (space for 6.5AH battery) Testing: Dynamic battery testing Operating Current: 150mA maximum (no peripheral devices fitted) Aux. Power O/P: 750mA maximum (for detectors etc.) Communications Maximum distance to remote devices: Specified Cable for High Level Lift Protocol Controller LAN: LAN Monitoring: Total Number of TS0869 Lift Controllers per Protocol Controller: Addressing: Operating Temperature: 1.5 km Belden 8723 or equiv. Continuous monitoring for Off-Line status of all devices on the LAN 16 Intelligent Four Lift Controllers selected from multiple Challenger systems Individually addressed by dip switches C High Level Lift Protocol Controller : Model TS0868 Issue I Revision I: October
4 Revised! see Protective Earthing Addendum High Level Lift Protocol Controller : Model TS0868 LAN System and Earth Connection Block Diagram NOTE 1: "TERM" link fitted on first and last devices on the LAN. In a "star" wiring configuration the "TERM" link is only fitted on the devices at the ends of the two longest LAN cable runs. NOTE 2: Recommended cable for Challenger LAN is Belden pair twisted sheilded data cable. NOTE 3: The Shield of each length of data cable is only connected at one end. NOTE 4: The earth terminals on each lift controller and High Level Lift Protocol Controller, must be earthed by connecting them all to a building earth point via a separate Earth wire. The separate Earth wire must be at least 2.5mm. A heavier guage is recommended for runs of over 500 metres. As the LAN connections of each TS0890 is an isolated RS485 connection it is not necessary to connect each earth to a common point. The "GND" link should not be fitted. This method of earthing will ensure that the difference in earth potential between any two Challenger products connected to the LAN remains at an acceptable minimum. Important Information - Please Note Version 1.04 of the TS0868 High Level Protocol Interface now has two (2) additional lift protocols. They are OTIS version 1 and EPL Kone version. The DIP switch setting for the four (4) protocols are: C D off off OTIS version 2 on off EPL KONE version 2 off on OTIS version 1 on on EPL KONE version 1 4 TS0868.P65 Issue I Revision I: October 1998
5 Auxillary Controller Events Controller Auxiliary Link Bank 1 Offline Controller Auxiliary Link Bank 2 Offline Controller Auxiliary Link Bank 3 Offline Controller Auxiliary Link Bank 4 Offline Controller Auxiliary Link Bank 5 Offline Controller Auxiliary Link Bank 6 Offline Controller Auxiliary Link Bank 7 Offline Controller Auxiliary Link Bank 8 Offline Controller Auxiliary Spare Controller Auxiliary Spare Controller Auxiliary Spare Controller Auxiliary Spare Controller Auxiliary Low Battery Controller Auxiliary Tamper Controller Auxiliary Fuse Fail Controller Auxiliary Mains Fail Auxillary Lift Events #1st #2nd #3rd #4th Lift Lift Lift Lift Lift Auxiliary Elevator Alarm Lift Auxiliary Independent Service Lift Auxiliary Emergency Stop Lift Auxiliary Elevator Failed to Start Lift Auxiliary Fire Service Lift Auxiliary Door Fully Closed Lift Auxiliary * Spare Lift Auxiliary * Emergency Power Operation Lift Auxiliary Spare Lift Auxiliary Spare Lift Auxiliary Spare Lift Auxiliary Spare Lift Auxiliary Spare Lift Auxiliary Spare Lift Auxiliary Spare Lift Auxiliary Spare * NOTE: Lift Auxiliary 7 on EPL Kone Lift = Call Button Latch Lift Auxiliary 8 on EPL Kone Lift = Spare # NOTE: The 1st, 2nd, 3rd & 4th lifts refer to the four lifts on each four lift controller (TS0869), NOT the 1st, 2nd 3rd, & 4th lifts in the building. High Level Lift Protocol Controller : Model TS0868 Issue I Revision I: October
6 N4131 Please note, this product conforms to the standards set by Standards Australia on behalf of the Australian Telecommunications Authority (AUSTEL) and the Australian Communications Authority (ACA). WARNING: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. The Challenger is designed and manufactured by: Tecom Systems 646 Whitehorse Road MITCHAM VIC AUST 3132 Telephone: Facsimile: Tecom Systems Pty. Ltd TS0868.P65 Issue I Revision I: October 1998
NETWORK CONCENTRATOR LINK. This equipment must only be installed and serviced by professional qualified personnel.
Revised! see Protective Earthing Addendum cback NOTE: This equipment must only be installed and serviced by professional qualified personnel. The Network Concentrator Link is a fully self contained unit
More informationIntelligent Four Lift Controller TS0869
The is a powerful real time lift controller for extensive multi level buildings requiring floor access control. The handles 4 lifts and access to 64 floors on each lift. CONNECTIVITY The can control 4
More informationTS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual
TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual P/N MAINST-867/869 REV 07 ISS 26NOV13 Copyright Trademarks and patents Manufacturer ACMA compliance Contact information 2013 UTC Fire
More informationCA111x-series Arming Station
GE Security CA111x-series Arming Station Installation and Programming Guide Contents Page Product Overview...1 Removing the Covers...2 Mounting the RAS...3 Tamper Switch...3 DIP Switch Settings...3 Connections...4
More informationUniversal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications
12 Universal Expander Module. Installation Notes. Revision 1.2 August. 2003. 1 Reporting Reporting with most Contact ID maps will treat the Mini Expander, Exp32 and Exp16 as the same. (With the exception
More informationIntegriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL
Revision 2.1 July. 2014 1 Integriti 8 32 Zone LAN Expander Module Kit P/N: 996005PCB&K For Rev. B PCB. INSTALLATION MANUAL Overview The Integriti 8 Zone Expander Module provides an additional 8 Zone inputs,
More informationQuick Start Installation Guide
apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building
More informationEA500. Installation Instructions Transponder
EA500 EN Installation Instructions Transponder EA500 Installation Instructions 1.0 Overview EN 2 1.0 Overview The EA500 Transponder is the Security Escort module that provides communications between the
More informationUC-2000 Installation Manual Unicorn Computers Technology Limited
UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller
More informationgenesis genesis Expander Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Expander Unit GEN-010
Australian Owned, Designed and Manufactured Expander Unit GEN-010 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify products
More informationUniversal Expander Module in Low Profile Enclosure. P/N: INSTALLATION MANUAL
Revision 2.14 October. 2009 1 Overview Universal Module in Low Profile Enclosure. P/N: 995004 INSTALLATI MANUAL The Universal Module connects to a Model 3000/Access 4000 system OR a Model 2000 system,
More informationTwo Door Controller GEN-045
Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify
More informationgenesis TECHNICAL MANUAL Two-Door Controller GEN-045
Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves
More informationInstallation Manual. Contents
CONCEPT IQ. Combined Installation Manual Rev 1.0 05/03 p1 Installation Manual Contents Section One: Concept IQ Hardware Overview 1.1 Typical Installation 1.2 Concept IQ Lockable Cabinet 1.3 Connecting
More informationCA-A480-A Elevator Controller. Reference & Installation Manual
CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................
More informationProduct Data Sheet. BMS/Graphics Interface. Features
BMS/Graphics Interface Product Data Sheet Features The Mxp-010 interface allows BMS systems and graphics PCs to be integrated with the Mx- 4000 series of Fire Control Panels and Remote Terminals. The interface
More informationSMARTLINE WIRELESS INTERFACE SYSTEM INSTALLATION MANUAL
SMARTLINE WIRELESS INTERFACE SYSTEM INSTALLATION MANUAL SmartLine (Wireless) Installation Manual v1.9 1.Contents 2. Overview...2 Equipment List...2 Introduction... 2 Monitoring Software Compatibility...2
More informationCDN502 HIGH DENSITY I/O ADAPTER USER GUIDE
CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER
More informationFibre Modem - Single-mode
Revision 1.0 November. 2006 1 - Single-mode P/N: : 995087 Model 3000 / Access 4000 Optically Isolated Interface INSTALLATION GUIDE OVERVIEW: The Inner Range Single-mode provides 2 separate, optically isolated
More informationRevision 1.4 October Integriti. Security Controller (ISC) SECURITY, ACCESS CONTROL & AUTOMATION SYSTEM INSTALLATION MANUAL
Revision 1.4 October. 2016. 1 Integriti Security Controller (ISC). 996001 0 Cont SECURITY, ACCESS CONTROL & AUTOMATION SYSTEM INSTALLATION MANUAL Contents PARTS LIST...2 INSTALLATION INSTRUCTIONS...2-4
More informationIntelligent 4 Door Access Module P/No: / INSTALLATION MANUAL
Revision 1.61 June. 2010. 1 Intelligent 4 Access Module P/No: 994012 / 995014 4 Controller with 4 or 8 Reader ports for Concept 4000 INSTALLATION MANUAL OVERVIEW The Intelligent 4 Access Module provides
More informationgenesis TECHNICAL MANUAL 16-Input Expander Unit GEN-010
16-Input Expander Unit GEN-010 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves
More informationConnecting a Cisco Reader Module
CHAPTER 3 Overview The optional Cisco Reader Module (Figure 3-1) is similar to the Cisco Physical Access Gateway, providing the same ports for Weigand readers and other input and output devices. The Cisco
More informationpro ACTpro IOM INPUT/OUTPUT MODULE Installation and Configuration Instructions for the ACTpro IOM Input/Output Module ACT Product Code: ACTPRO IOM
pro ACTpro IOM INPUT/OUTPUT MODULE Installation and Configuration Instructions for the ACTpro IOM Input/Output Module ACT Product Code: ACTPRO IOM pro CONTENTS Technical Specification... 4 Product Overview...
More informationELSEMA GLR Applications Automatic gates. Security systems. Timer controlled outputs. Simple on/off functions.
GLR43301 Single Channel 433MHz Gigalink Receiver with Timer Controlled Relay Output Features Wide supply connection 10.0 to 28.0 Volts AC/DC Highly sensitive receiver input stage. When used with GLT433
More informationIntelligent Devices IDI 1100 Series Technical Manual
Intelligent Devices IDI 1100 Series 4411 Suwanee Dam Road, Suite 510 Suwanee, GA 30024 T: (770) 831-3370 support@intelligentdevicesinc.com Copyright 2011, Intelligent Devices, Inc. All Rights Reserved
More informationC-Bus Pascal Automation Controller
C-Bus Pascal Automation Controller Installation Instructions 5500PACA Copyright Clipsal Integrated Systems Pty Ltd 2005. All rights reserved. This material is copyright under Australian and international
More informationCDN503 HIGH DENSITY I/O ADAPTER USER GUIDE
CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE 13050301 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN503 PRODUCT OVERVIEW 1 DN503 INSTALLATION 1 POWER
More informationThe Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.
Peripheral Relay The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Up to 16 Cards can be connected to a multi-loop panel
More informationLab 5: Access Control Training Station
Lab 5: Access Control Training Station Learning Objectives At the end of the lab, trainees should be able to: 1. Understand the functional block and hardware of an access control system. 2. Understand
More informationInstalling the Cisco AS5400XM Universal Gateway
CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,
More informationInstalling Sentor. Hardware Installation
Remote base site monitoring and control Installing Sentor Hardware Installation Copyright 2000 Sentor Monitoring Systems Pty Ltd Contents: 1 Introduction... 1 2 Sentor GUI... 2 3 ST3000 Controller... 3
More informationgenesis Master Unit GEN-001 genesis Master Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured
Australian Owned, Designed and Manufactured Master Unit GEN-001 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify products
More information50 Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)
Installation Manual Catalog 5110 Accessory 72A Serial Module for 4000 Series, 7000 Series, & Series 300 ATSs Contents of Accessory 72A Kit 755257 Serial Module DIN Rail & Hardware 10 inch Serial Cable
More information6222 Two Door Module Technical Operations Manual
6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5
More informationEnergy Management System. Operation and Installation Manual
Energy Management System Operation and Installation Manual AA Portable Power Corp 825 S 19 TH Street, Richmond, CA 94804 www.batteryspace.com Table of Contents 1 Introduction 3 2. Packing List 5 3. Specifications
More informationInstallation Instructions
Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line
More information1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT
Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULACM4CB HP600ULACM8CB Access Control Power Supply/Charger with Power Distribution Controller PN 52395:A 1/05/06 ECN
More informationModel 3OOO ACCESS 4000
Revision 5.0 April. 2004 1 Model 3OOO 0 Cont & ACCESS 4000 Control Module 995001 / 995002 SECURITY, ACCESS CONTROL & BUILDING AUTOMATION SYSTEM INSTALLATION MANUAL OVERVIEW The 3000/Access 4000 provides
More informationBioPointe Reader Installation Guide
BioPointe Reader Installation Guide What s in this Guide Installation Steps 1 Key Parts of the BioPointe Reader 2 Cabling Requirements 3 Power Connection 3 PXL-500W Wiegand Controller Connection 3 Serial
More informationME778C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: 10-Pin RJ.
ME778C-RJ45 Line: RJ-45 MAIN MODULE Mini Driver MP Card ME778C-RJ45 Power Line: RJ-45 Unit A -TD -RD -CD -TD Serial: 10-Pin RJ INTERFACE MODULE (REAR CARD) Unit B -RD -CD Serial: 10-Pin RJ LO Z A HI Z
More informationOPERATOR MANUAL OSD136 SYNCHRONOUS FIBER OPTIC RS232 MODEM
OPERATOR MANUAL OSD136 SYNCHRONOUS FIBER OPTIC RS232 MODEM Page 2 of 16 INDEX 1. TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4 1.1.3 FEATURES AND BENEFITS...
More informationInstalling the DX LCD Display
DX LCD Display User s Guide 3-1 Chapter 3 Installing the DX LCD Display Introduction Use the DX LCD Display as either a portable device, or permanently mount it in a panel or on the wall. For panel and
More informationTB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.
NXT x.0 Wiring and Layout Diagrams. NXT-x I/O Module Shielded CAT- Cabling Shielded -Conductor Cabling total cable length 00 feet max (0 m) Brown/Green/Orange w/o Stripe Brown/Green/Orange with Stripe
More informationUnique Micro Design First Choice of Professional Systems Intergrators. Model 361 Terminal Keyboard Wedge User Manual
Model 361 User Manual Unique Micro Design First Choice of Professional Systems Intergrators Model 361 Terminal Keyboard Wedge User Manual Document Reference : DOC-M361-UM UMD Part Number : 6-0361-993-5
More informationWiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.
3-3 Wiring NQ-Series models have, besides one power connector, a number of communication ports. Please refer to Table 2.2: Common specifications for NQ-Series and Table 2.3: Specifications per NQ-Series
More informationDESIGN GUIDE FOR INFINITY SYSTEMS
Doc. 6001564 Rev B DESIGN GUIDE FOR INFINITY SYSTEMS WITH STAND ALONE OR MULTI-LINK LINK FIRMWARE TABLE OF CONTENTS 1. CABINET DIMENSIONS...3 2. WIRE CHART...3 A. CABLING TO THE MAIN PROCESSOR BOARD...
More informationTS1001 Touch Screen Arming Station Installation Manual
TS1001 Touch Screen Arming Station Installation Manual P/N MAINST-TS1001 REV 05 ISS 04MAR15 Copyright Trademarks and patents Manufacturer Agency compliance 2015 UTC Fire & Security Australia Pty Ltd. All
More informationParallel to Serial and Serial to Parallel Converter CE Model 232SPS2 Documentation Number 232SPS2-3903m
Parallel to Serial and Serial to Parallel Converter CE Model 232SPS2 Documentation Number 232SPS2-3903m This product designed and manufactured in Ottawa, Illinois USA of domestic and imported parts by
More informationCYPRESS " " EXP SPX Expansion interface! modules EXP-2000_MAN_0314
CYPRESS EXP-2000 SPX Expansion interface! modules The EXP-2000 provides additional Door/Panel interface points to most SPX products. The EXP-2000 uses a local RS-485 network through an SPX gateway device.
More informationAVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL
AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL GENERAL DETAIL The AVC2 will control a stereo channel to a preset maximum output level allowing the maximum sound level of a system to be controlled. The AVC2
More informationQuick Start Installation Guide
RM-DCM-2 Quick Start Installation Guide Version G0 Document Part Number UM-215 May 2010 OVERVIEW The RM-DCM-2 is a UL294 Listed and UL1076 Listed door control module that includes the RM-4E Reader Module
More informationConnecting a Cisco Input Module
CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each
More informationCard Descriptions and Wiring Manual. Load Computer 1010 CJ
Card Descriptions and Wiring Manual Load Computer CJ Table of Contents CHAPTER 1 Card Descriptions and Terminal Layouts 1.1 CPU Card - S10CPU-xxx-I3..................................... 1-2 1.1.1 Card
More informationIntroduction. General Ratings
Introduction Storage temperature Operating temperature Humidity Weight Dimensions Screw terminal wire gauge Supply voltage Supply currents Maximum baud rate Unit Mounting Housing o -20 to +70 C o Allows
More informationJED MICROPROCESSORS PTY LTD
JED MICROPROCESSORS PTY LTD 173 Boronia Rd, Boronia, (PO Box 30), Victoria, 3155, Australia. Phone: +61 3 9762 3588, Fax: +61 3 9762 5499. Web site: http://www.jedmicro.com.au email: jed@jedmicro.com.au
More informationGT- IRDM-9603 Product description Rev. 2 17/06/2014
GT- IRDM-9603 Product description Rev. 2 17/06/2014 1 1. Overview The GT- IRDM- 9603 is a complete Satellite Terminal solution for Satellite applications. Based on IRIDIUM 9603 module. 2. Hardware Interface
More informationOPERATOR MANUAL OSD156 SYNCHRONOUS FIBER OPTIC RS232 MODEM
OPERATOR MANUAL OSD156 SYNCHRONOUS FIBER OPTIC RS232 MODEM OSD156 SYNCHRONOUS FIBER OPTIC RS232 MODEM Document No. 10104401 Page 2 of 14 INDEX 1. TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION...4 1.1.1
More informationJob Aid: Connector and Cable Diagrams (Pinout Charts)
Job Aid: Connector and Cable Diagrams (Pinout Charts) The pinout charts in this document provide wire color and connector pin numbers for: Circuit pack codes and descriptions for all circuit packs (unless
More informationT1K MODBUS Base Controller Specifications
Base Controller 1 2 In This Chapter.... Base Controller Setting the DIP Switches Setting the Rotary Address Switches Port Pin out and Wiring RJ12 Serial Port Pin out and Wiring 2 2 Base Controller General
More informationPacom Hardware Installation Guide
Pacom Hardware Installation Guide 800 010 001 June, 2008 Version 1.5 Copyright 2008 Pacom Systems Pty Ltd All Rights Reserved No part of this document may be reproduced, transmitted, transcribed, stored
More informationModel: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated:
Wiring Guide EP.L3800 Version 1.03 Last Updated: 13-10-2014 1 Note: L3800 is the serial enabled lift controller. L3800 will ship with a HIO board in a package which can cater up to 8 floors. It can connect
More informationModbus Communications Board
- Modbus Communications Board (RS-485) User Manual Document No. 360-0099-01 (Revision G) Sensidyne, LP. 1000 112 th Circle N, Suite 100 St. Petersburg, Florida 33716 USA 800-451-9444 +1 727-530-3602 +1
More informationPXL-250 Tiger Controller
PXL-0 Tiger Controller This quick start guide is made up of specification sheets, a DO/DON T list, basic installation drawings, first time power-on instructions, and short descriptions of key terms and
More informationMouldFlo Wiring Manual
MouldFlo Wiring Manual Copyright (C) 2013 Move Innovation ApS http://www.moveinnovation.dk Table of Contents Introduction... 2 MouldFlo I/O (MFIO)... 3 Power Supply Connection... 4 Manifold Connector Ports...
More informationD/E Remote Relay Panel User Guide
D/E Remote Relay Panel User Guide This manual should remain with the unit. D/E Remote Relay Panel Detailed Specifications...2 Environmental Specs...2 Power Supply Requirements...2 Relay Outputs (8)...2
More informationChallenger Version 8 Programming Macro Logic.
Challenger Version 8 Programming Macro Logic. This document provides details of the requirements for planning and programming Macro Logic in a Version 8 Challenger System for use in Alarm Control and/or
More informationCTI CALL INFORMATION INTERFACE
CTI CALL INFORMATION INTERFACE MODEL CN-4750 SERIAL/ITEM 533/nnn OPERATOR MANUAL Issue 3, FEB, 2002 AUTHOR: PETER ZEUG PATENTS PENDING DESIGNED AND MANUFACTURED IN AUSTRALIA DESIGN TWO THOUSAND PTY LTD
More informationInstallation & User Manual
Contents Installation Instructions 3 Installation Diagrams 4 System Overview 6 Wiring Diagrams 8 Network Diagrams 9 Operation Instructions Fingerprint Enrollment 12 21 Wi-Enterprise Controller www.transmittersolutionssmart.com
More informationInstallation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT
Installation Instructions i-net Access Control Units Part Code: IA-PCB IA-ACB IA-ACU IA-KIT This device is configured for DHCP. Identity Access software will find this device, go to setup and controller,
More informationCardax FT Controller 3000
Installation Note Cardax FT Controller 000 CAUTION This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any
More informationConnecting a Cisco Output Module
CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which
More informationADDENDUM FOR 20, 27, & 28 OPTIONS
ADDENDUM FOR 20, OPTIONS GENERAL The 20, 27, and 28 option provides for an alarm contact OR an AC transfer switch on EXELTECH XP Series inverters. The alarm relay monitors the inverter s AC output and
More informationNetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup
NetworX Series NX-0E RELAY EXPANDER NX-0E OUTPUT EXPANDER Installation and Startup NX-0E / NX-0E AUXILIARY MODULES TABLE OF CONTENTS I. GENERAL DESCRIPTION... II. WIRING INFORMATION... III. NX-0E TERMINAL
More informationBewator Granta Controller Installation Handbook
Bewator Granta 4101-2 Controller Installation Handbook Copyright 2004 Bewator AB, Solna. This handbook is based on the best information available to Bewator Cotag at the time of publication. Although every
More informationIC-485S /IC-485SI. If anything is damaged or missing, contact your dealer.
User Manual IC-485S /IC-485SI Read this guide thoroughly and follow the installation and operation procedures carefully in order to prevent any damage to the units and/or any devices that connect to them.
More informationModel: 8R5PR. 8 Channel RS485 Relay Xpander. Installation Manual. Product Revisions F/G
Model: 8R5PR 8 Channel RS485 Relay Xpander Installation Manual Product Revisions F/G 12200 Thatcher Court Poway CA 92064 U.S.A. TEL: 619-486-8787 FAX: 619-486-8789 www.jdstechnologies.com 0 Features 8
More informationRevision 3.1 March IP Door Controller. P/No: IPD INSTALLATION MANUAL OVERVIEW
Revision 3.1 March. 2010. 1 IP Door Controller P/No: 995002IPD INSTALLATION MANUAL OVERVIEW General information. The Concept IP Door Controller provides an advanced network solution for fully Integrated
More informationSmartLock Controller INSTALLATION MANUAL
SmartLock Controller INSTALLATI MANUAL November 2015 Table of Contents INTRODUCTI... 3 Diodes... 4 Terminal Strips and Cable... 5 SPECIFICATIS... 6 SMARTLOCK CTROLLER LAYOUT... 8 LED Indicators... 9 Mounting...
More informationInterface RS485-TTL CODE: INTR. v.1.0 EN* Edition: 3 from
Interface RS485-TTL v.1.0 CODE: EN* Edition: 3 from 05.12.2013 Supersedes the: 2 from 19.12.2012 TABLE OF CONTENTS 1. General description.... 3 2. Components arrangements.... 3 3. Connection to the RS485
More informationInstruction Manual. Multilin TM 8 Series Retrofit Kit * A1* GE Grid Solutions LISTED
GE Grid Solutions Multilin TM 8 Series Retrofit Kit Instruction Manual 8 Series version: 1.6x GE publication code: 1601-0701-A1 (GEK-130906) LISTED *1601-0701-A1* Copyright 2016 GE Multilin Inc. All rights
More informationNetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup
NetworX Series NX-0E RELAY EXPANDER NX-0E OUTPUT EXPANDER Installation and Startup NX-0E / NX-0E AUXILIARY MODULES TABLE OF CONTENTS I. GENERAL DESCRIPTION... II. WIRING INFORMATION... III. NX-0E TERMINAL
More informationPIM Presco Interface Module
INTRODUCTION The Interface Module (PIM) can be used to convert commonly used data formats to Nidac, or format data. PIM Interface Module Series 2 Revision B FEATURES Converts from,, Nidac, Clock & Data
More informationAmano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL
MODEL NUMBER: XRT910-0-0-AC-XX XRT920-0-0-AC-XX AMANO itrt Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power Designed to work
More informationFire Safety. Installation Instructions. Models PIM-2/PAL-1 Peripheral Interface Module 2/Parallel Printer OPERATION INSTALLATION
Fire Safety Installation Instructions Models PIM-2/PAL-1 Peripheral Interface Module 2/Parallel Printer OPERATI The SIEMES Model PIM-2 module is an interface that allows the connection of UL listed EDP
More information1. Introduction ALSPA MV DELTA
1. Introduction ALSPA MV DELTA 1.2.4 MV3000e User Input/Output (I/O) Termination Panel The User Termination Panel, shown at Figure 1-5, provides the input and output termination facilities for signals
More informationNBF-3. User Manual. NMEA 0183 Buffer. For all variants: NBF-3-BAS, Rev A. Issue 1.01
NBF-3 NMEA 0183 Buffer User Manual For all variants: NBF-3-BAS, Rev A Issue 1.01 NMEA 0183 Buffer - NBF-3 Contents Company Information 4 Important Notices 5 Trademarks and Registered Trademarks 5 Fair
More informationS125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags
S125 Multi-Purpose 125 KHz RFID Reader 44 mm USER MANUAL MULTI PURPOSE 84 mm ONLINE & OFFLINE MODE BUILT-IN RELAY 125 KHz RFID EM4100/2 Cards & Tags 9V/24V DC Operating Voltage, AC (optional) 3 Online
More informationInstallation & User Manual V2.08
YOUR SECURITY IS OUR PRIORITY Other products from GSD Contents Installation Instructions Installation Diagrams System Overview Wiring Diagrams Network Diagrams Operation Instructions Fingerprint Enrollment
More informationThe Exp-007 unit connects directly to Remote Status Indicator units to provide 2 programmable 1-Amp rated, volt free, clean contact outputs.
Relay Outputs The Exp-007 and Exp-008 are internal peripherals for use with the Ex3000 gas extinguishing system. The units are used to expand the number of outputs available on the system either local
More informationDAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL
DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION... P.2 2. STANDARD AND OPTIONAL PARTS LIST..... P.2 3. FEATURE DEFINITIONS... P.3 4. TERMINAL DRAWING AND SPECIAL
More informationVISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control
VISTA 12a / 48a TECHNICAL TRAINING The Best in Security plus Everyday Convenience & Control Version #.007 7th June 2005 VISTA 12a / 48a Training Guide Index 1. Vista Family Features....... p. 3 2. Wiring
More informationSmartLock Pro INSTALLATION MANUAL
SmartLock Pro INSTALLATI MANUAL July 2010 Cutting edge simplicity Table of Contents INTRODUCTI... 3 Diodes... 3 Power Supply Notice... 3 Terminal Strips and Cable... 4 SPECIFICATIS... 5 SMARTLOCK CTROLLER
More informationS SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux
S SENECA Z-PC Line EN Installation Manual Contents: - General specifications - Technical features - Modbus and CANopen connections - Installation rules - Electrical connections - LEDs signallings - Default
More informationINSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code:
INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA-675-001 Revision 1.0 Date Code: 1-1-2018 Table of Contents Table of Figures... 3 SPECIFICATIONS:... 4 INSTALLATION... 5 General:... 5 Physical Installation
More informationMOULDFLO WIRING MANUAL
MOULDFLO WIRING MANUAL MOULDFLO A/S Copyright 2017 2860 Søborg - Denmark (DK) www.mouldflo.com 1 Contents Introduction... 3 Mouldflo I/O (MFIO)... 4 Power Supply Connection... 5 Manifold Connector Ports...
More informationTraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE
TTDM-128 TraceTek Leak Detection Master Module Installation Instructions TRACETEK APPROVALS AND CERTIFICATIONS TYPE NM General Signaling Equipment 76LJ GENERAL INFORMATION Please read these instructions
More informationWAC-IPMG200 IP Based Access Control System
WAC-IPMG200 IP Based Access Control System 1. Technical Specifications 2 Door Controller Size (box) 350mm x 360mm x 85mm Temperature -5 C to +50 C Power Main Power : 220-240VAC, 50/50Hz, Power for main
More informationEIDX_M Series INSTALLATION GUIDE INTRODUCTION. A Line of Managed Ethernet Switching Hubs
EIDX_M Series A Line of Managed Ethernet Switching Hubs INTRODUCTION INSTALLATION GUIDE The EIDX_M Series of managed Industrial Ethernet switches provides the user with a sophisticated instrument with
More informationEP/2 Installation Instructions
1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in
More information