genesis Master Unit GEN-001 genesis Master Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured

Size: px
Start display at page:

Download "genesis Master Unit GEN-001 genesis Master Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured"

Transcription

1 Australian Owned, Designed and Manufactured Master Unit GEN-001 Genesis Electronics Australia Pty Ltd Distributed by: Genesis reserves the right to change or modify products without notice. This manual assumes installers of this product are professionals within the electronic security, access control and automation industry. As such, knowledge of these industries on the part of the installer is assumed. Genesis takes no responsibility for any damage, financial loss or injury caused to any equipment, property or persons resulting from the correct or incorrect use of any Genesis Electronics devices. genesis The very latest innovation in security and access TEHNIAL MANUAL Revision 2.02 September 2002 Genesis Electronics Australia Pty Ltd Page 24 Revision 2.02 September 2002

2 Table of ontents TABLE OF ONTENTS 2 Notes PARTS HEKLIST 3 SPEIFIATIONS 4 FEATURES AND BENEFITS 5 TERMINAL BLOK MOUNTING 6 MASTER UNIT LAYOUT 7 INPUT LAYOUT AND WIRING 8 POWER SUPPLY AND OUTPUT LAYOUT 10 MASTER UNIT EXPANSION 11 MASTER UNIT PROESSOR 12 MASTER UNIT OMMUNIATIONS 13 MOUNTING 14 GENESIS LAN 15 POINTS TO NOTE 17 LITHIUM BATTERY REPLAEMENT 18 SAMPLE EOL RESISTOR VALUES 19 Page 2 Revision 2.02 September 2002 Revision 2.02 September 2002 Page 23

3 Notes Parts hecklist: 1 x Master Unit (GEN-001) in Metal Equipment abinet (GEN-130) 1 x Telephone Lead 1 x 16 volt A, 1.5 Amp Plug Pack 1 x Pair of Battery Leads 16 x 10K Resistors (1% Tolerance) 16 x 4.7K Resistors (5% Tolerance) 23 x 2 pin Terminal Blocks 2 x 3 pin Terminal Blocks 1 x 2 pin header 1 x 2 pin jumper 2 x nuts 2 x flat washers 1 x star washer 1 x Master Unit Technical Manual (this manual) aution: All Genesis devices are electrostatic sensitive devices. As such, all care should be taken to ensure appropriate procedures are in place when handling and installing Genesis devices. This may include, but is not limited to wearing an appropriately earthed, conductive wrist strap to limit electrostatic discharge into Genesis devices. Page 22 Revision 2.02 September 2002 Revision 2.02 September 2002 Page 3

4 Specifications: Dimensions (H x W x D): GEN-001 PB = 298 x 140 x 55 mm GEN-130 box = 442 x 305 x 78 mm Processor: 16 bit microprocessor Memory: 256k ROM and 20k RAM 2 Megabits Standard 8 Megabits Optional Input Voltage: 16V A Battery Voltage: 12V D Standby urrent Draw: 90mA 140mA when dialling Outputs Fixed: 2 x 12V D, 1 Amp maximum fused and monitored outputs Programmable: 4 x 12VD, 1 Amp maximum fused and monitored transistor outputs Piezo Buzzer: Programmable on-board Piezo Buzzer Notes Inputs Programmable Inputs Fixed Inputs 16 x four state, tamper monitored inputs 1 x onboard tamper input Expansion With GEN-020 I/O Expander Inputs Additional 16 (totalling 32) Outputs: Additional 4 (totalling 8) ommunication Dialler Format: P Interface: Securitel: ontact ID RJ-45 connector for RS-232 to P baud rate RJ-45 connector for RS-232 to STU (with additional chipset) Page 4 Revision 2.02 September 2002 Revision 2.02 September 2002 Page 21

5 Sample EOL Resistor Values: 3K3/3K3 N/ 3K3 = Sealed 6K6 = Unsealed Genesis AD Values Tamper High 135 Tamper Low 72 Unsealed High 85 Unsealed Low 72 3K3/3K3- N/O 3K3 =Sealed 1K7 = Unsealed Genesis AD Values Tamper High 135 Tamper Low 72 Unsealed High 135 Unsealed Low K Single EOL Genesis AD Values Unsealed High 165 Unsealed Low 140 6K8 Single EOL Genesis AD Values Unsealed High 135 Unsealed Low 110 4K7 Single EOL Genesis AD Values Unsealed High 110 Unsealed Low 85 3K3 Single EOL Genesis AD Values Unsealed High 95 Unsealed Low 60 2K2 Single EOL Genesis AD Values Unsealed High 70 Unsealed Low 50 1K Single EOL Genesis AD Values Unsealed High 35 Unsealed Low 25 Page 20 Revision 2.02 September 2002 Features and Benefits: The Genesis Master Unit (MU) is the brains of the Genesis system. Using the latest technology, its high speed operation and LAN communication allows connection of up to 127 additional devices to the Genesis system. The modular design of the Genesis system allows for the system to be expanded as required to provide up to 512 inputs, 512 outputs and 192 access control doors. The Genesis Master Unit provides programming functionality that allows the Genesis system to be used for alarm, access control and automation functions. A few of the features of the Genesis Master Unit are listed below; P Port Onboard 1 Inputs per system 512 Flags per input 8+1 Programmable EOL values 16 Outputs per system 512 Output Lists 128 Access Doors per system 192 Door Access Lists 128 Areas in the system 64 Flags per Area 8 Area Lists 64 Area Access Lists Day locks 64 lock Lists 128 Diallers 16 User Groups 128 Flags per Group 8+2 Azone (anti-passback zones) 250 Global Flags 128 Holidays 64 Holiday Lists 64 Message Text (RAS or RS-232) 100 System Variables 128 Revision 2.02 September 2002 Page 5

6 Terminal Block Mounting: Sample EOL Resistor Values: 1 x 3 pin block 3 x 2 pin blocks 4 x 2 pin blocks 4 x 2 pin blocks 4 x 2 pin blocks 4 x 2 pin blocks 4 x 2 pin blocks 1 x 3 pin block 10K/4K7 N/ 10K=Sealed, 14K7=Unsealed Genesis AD Values Tamper High 180 Tamper Low 140 Unsealed High 165 Unsealed Low K/4K7 N/O 14K7 = Sealed 10K = Unsealed Genesis AD Values Tamper High 180 Tamper Low 140 Unsealed High 180 Unsealed Low 165 Short ircuit Short = Sealed Open = Unsealed Genesis AD Values Unsealed High 20 Unsealed Low 0 Open ircuit Open = Sealed Short = Unsealed Genesis AD Values Unsealed High 255 Unsealed Low 25 10K/10K N/ 10K = Sealed 20K = Unsealed Genesis AD Values Tamper High 200 Tamper Low 140 Unsealed High 165 Unsealed Low K/10K N/O 10K = Sealed 5K = Unsealed Genesis AD Values Tamper High 165 Tamper Low 85 Unsealed High 165 Unsealed Low 140 2K2/6K8 N/ 2K2= Sealed 9K = Unsealed Genesis AD Values Tamper High 160 Tamper Low 50 Unsealed High 76 Unsealed Low 50 2K2/6K8 N/O 9K = Sealed 2K2 = Unsealed Genesis AD Values Tamper High 160 Tamper Low 50 Unsealed High 160 Unsealed Low 135 Page 6 Revision 2.02 September 2002 Revision 2.02 September 2002 Page 19

7 Lithium Battery Replacement Procedure: Master Unit Layout: The lithium battery located on the GEN-001, Master Unit PB board, provides back up of power to the programming data, in the event of power supply failure. Each battery has it own life, and they may require to be replaced from time to time. Page 10 Page 13 1) The Lithium Battery can be replaced while power is present to the PB Board, but precautions must be taken not to short any components on the board. 2) If the supply of power is not present and the battery is removed ALL PROGRAMMING DATA WILL BE LOST. 3) It is therefore recommended that prior to replacing the battery, all programming data be backed up and uploaded onto a P or Laptop omputer. 4) Remove the BATTERY LINK located next to Lithium battery. This will disconnect the battery from PB Board. 5) arefully remove the battery from its holder. 6) Insert new battery ensuring the +ve side of the battery is facing upwards. 7) Inspect that the battery is properly located in its holder. 8) Reconnect the BATTERY LINK. AUTION There is a danger of explosion if the battery is incorrectly replaced. Replace only with the same or equivalent type of battery, as recommended by Genesis Electronics Australia currently R2450 3V Lithium Battery. Dispose of used batteries according to the battery manufacturer s instructions. Page 8 Page 11 Page 12 Page 18 Revision 2.02 September 2002 Revision 2.02 September 2002 Page 7

8 Input Layout and Wiring: 16 Input Terminals, with individual common returns are supplied on the Genesis Master Unit. The Genesis Master Unit allows for each input to have a different End of Line resistor value. (up to 16 EOL values). This includes tamper monitoring, through Dual End of Line resistors. The Genesis panel is supplied with the following resistor combination as standard: 10KΩ = Sealed 14.7KΩ = Alarm (10KΩ + 4.7KΩ) Points to Note: DO NOT common the 0V D, or +12V D, of power supplies and Genesis devices. Removal of the Serial Number from any Genesis device will immediately void any warranty applicable to it, or any interconnected Genesis device. LIGHTNING PROTETION: In areas where electric storms provide potentially high risks to electronic equipment, it may be required to add additional protection using gas dischard protectors, called arresters. The Genesis Master Unit has been designed to allow for installation of these arresters if required, to protect both the Telephone and RS485 communication lines. However, these values can be changed from within the Genesis Technician Software, to suit most resistor configurations. Example 1 PIR Dual EOL, Normally losed 4.7KΩ 10KΩ ALA RM TAM PER Location for Installation of Telephone Line Protection Arrester Location for Installation of RS- 485 ommunication Line Protection Arrester Example 2 Switch Dual EOL, Normally losed KΩ 10KΩ Please contact your Authorised Genesis Distributor for more information regarding supply and installation of lightning protection arresters to the Genesis Master Unit.. Page 8 Revision 2.02 September 2002 Revision 2.02 September 2002 Page 17

9 Genesis LAN (cont.): onnect to ommunications Earth Master Unit GEN001 Remote Access Station GEN030 Expander Unit GEN010 Two Door ontroller GEN045 SHD B A SHD B A SHD B A SHD B A The Master Unit must always be the first device on the LAN. This device is factory fitted with a 180Ω LAN Termination Resistor. The shield from the LAN cable should run the length of the LAN, and should be connected to a communications earth, at the Master Unit only. The shield s on each device are for connection of shield cables, and do not connect to the device proper in any way Up to 127 additional Genesis devices in total can be connected to the Genesis LAN, across a total LAN length of up to 1500 meters. The last device on the Genesis LAN must be fitted with its termination link. This link fits a 180Ω resistor to the last device on the LAN. No other devices should have a termination link fitted. If connected as described above, the LAN should have an impedance of approximately 90Ω, plus the resistance of the LAN cable. *Don t test LAN impedance with any devices powered up. Ensure the cable shield is not connected to any ground or to any voltage on any device and that the cable shield is only connected to a communications earth at the Master. orrect LAN configuration orrect LAN onfiguration Input Wiring: Example 3 PIR Single EOL, Example 4 Smoke Detector Normally losed Single EOL, Normally Open ALA RM Example 5 Switch Single EOL, Example 6 Switch Single EOL, Normally losed Normally Open Example 7 Smoke Detector Dual EOL, Normally Open 4.7KΩ 10KΩ ALA RM TAM PER Example 8 Switch Dual EOL, Normally Open 4.7KΩ 10KΩ TAM PER 10KΩ 10KΩ KΩ ALA RM Master Unit Layout: 8 10KΩ TAM PER 4 6 Note: These examples are for the purpose of illustrating the most commonly used input wiring configurations. Different detection devices may require wiring in a different fashion to these examples. Page 16 Revision 2.02 September 2002 Revision 2.02 September 2002 Page 9

10 Power Supply and Output Layout: 12V D battery s onnect to s as follows; +12V D 0V D Note: Reversal of battery s may damage components Auxiliary Power s 2 x 12VD Terminals +12V D 0V D +12V D 0VD Rated to 1Amp Maximum Programmable Outputs The default output descriptions and node addressing are, in order; Siren 2 Node 2 Strobe 2 Node 4 Siren 1 Node 1 Strobe 1 Node 3 4x 12VD Terminals, in the standard format of ; +12V D 0V D Rated to 1Amp Maximum Note: The naming of the 4 programmable outputs is intended for descriptive purposes only. These outputs can be used to control other devices requiring programmable 16 Volt A Input Used to terminate the supplied 16V A plug pack, the s are as follows; 16V A Earth Pin 16V A Fuses Each 12V D output is separately fused and monitored. Each Fuse is rated to 1 Amp The Fuses in order are; Aux Output 1 Aux Output 2 Siren 2 Output Strobe 2 Output Siren 1 Output Strobe 1 Output Note: While each fuse is rated to 1 Amp, the total D current drawn from the Master Unit should not exceed 1 Amp. Piezo Buzzer Fully programmable piezo buzzer is supplied on the Genesis Master Unit. Genesis LAN: Genesis uses industry standard RS-485 LAN communication to ensure fast efficient network communication between devices. The Genesis LAN operates at a communication speed of 19,200 baud between up to 128 devices over a total LAN distance of up to 1500 meters. In order to ensure that a high level of performance is achieved, it is necessary to connect the Genesis LAN in the recommended method. To this end, it must be twisted pair data cable that is used for the Genesis LAN. Belden 8723 (RS-485) cable, or equivalent is recommended. A standard must be applied when wiring from one LAN leg to another. For example, the A leg on a Master Unit must always be connected to the A legs on other Genesis devices, while the B leg must always be connected to the B legs on other Genesis devices. A very common communication problem is where the A and B lines are reversed. If this occurs, then some devices may appear on-line, while others are off-line. The Genesis LAN is an industry standard multi-drop RS-485 configuration. Do Not Tee Off, or Star configure your LAN. While the LAN may function in these configurations, Genesis cannot guarantee proper LAN performance. X X Improper Star onfiguration Improper Tee Off onfiguration Page 10 Revision 2.02 September 2002 Revision 2.02 September 2002 Page 15

11 Mounting: Master Unit Expansion: The Master Unit is designed to mount within the GEN-130, metal equipment cabinet. Using this cabinet, it is possible to mount the Genesis Master Unit, aswell as two other small Genesis devices (Two Door ontroller, 32 Output Open ollector Module, 8 Relay Output Module or I/O Expander). - Avoid installing the Master Unit outdoors. - Avoid installing the Master Unit where it may be exposed to moisture, either directly (Rain, Sprinklers, Hoses), or by condensation. BATTERY LINK This link supplies power to the Master Unit s memory. If this link is removed while the panel is powered down, it will erase all programming from the Master Unit. This Link must be fitted as soon as the panel is removed from the packing box. I/O EXPANDER BUS This 16 pin socket is provided for connection between the GEN-001 Master Unit and the GEN- 020 I/O Expander. The I/O Expander provides an additional 16 system inputs, and 4 change over contact relays TAMPER INPUT: Provided to allow normally closed connection of a cabinet tamper switch to this device. LITHIUM BATTERY This battery provides backup power to the Master Unit memory, in the event of power supply failure. Please refer to page?? for more information regarding this battery. RESET BUTTON Used when generating a hardware reset to the device processor. Use only under instruction from your Genesis Distributor. H7 Reserved for Factory Use. Do NOT fit a jumper to this link SERIAL NUMBER Each Genesis device is fitted with it s own unique Serial Number. This number will need to be entered into the Genesis Master Unit, via the technician software, before the device will come on line. Removal of Serial Number will void Warranty Page 14 Revision 2.02 September 2002 Revision 2.02 September 2002 Page 11

12 Master Unit Processor: Master Unit ommunications: TELEPHONE ONNETION Used to allow connection to a telephone service, using the supplied telephone lead. LAN TERMINALS: The A and B LAN s are designed for the Genesis LAN to be terminated into. The A and B lines must always be connected to the A and B s on other Genesis devices. The shield (SHLD) has been supplied to secure the cable shield only. Please refer to page 12 for further information on the Genesis LAN. P INTERFAE Provided to allow serial RS-232 connection to a laptop or personal computer, using the GEN-150 omputer onnection Lead. This allows for use of the Genesis Technician Software, or user interface software PROGRAMMING HEADER The programming header is supplied to allow easy flash upgrading to any future Genesis features. Please contact your distributor for more details. L4 and L5 LED s Provides a quick indication as to system status. Flashing L4 LED = Device Processor OK. Flashing L5 LED = LAN omms OK RS-232 PORT Used to allow connection interfacing to a STU232, Serial Securitel Interface Unit. Only available for use if the optional GEN-100 RS-232 Output hipset is fitted U24 and U27 HIP SOKETS Provided to allow installation of optional GEN-100 RS-232 Output hipset. This chipset is necessary if the GEN-001 Master Unit is to be connected to a STU232 Serial Securitel Interface Unit Note: Some earlier versions of the GEN-001 Master Unit have a third RS-232 Port, and hip Sockets fitted. This port and socket are now redundant, and are not addressable in future firmware. Page 12 Revision 2.02 September 2002 Revision 2.02 September 2002 Page 13

genesis genesis Expander Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Expander Unit GEN-010

genesis genesis Expander Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Expander Unit GEN-010 Australian Owned, Designed and Manufactured Expander Unit GEN-010 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify products

More information

genesis TECHNICAL MANUAL 16-Input Expander Unit GEN-010

genesis TECHNICAL MANUAL 16-Input Expander Unit GEN-010 16-Input Expander Unit GEN-010 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves

More information

genesis genesis I/O Expander - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured I/O Expander GEN-020

genesis genesis I/O Expander - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured I/O Expander GEN-020 Australian Owned, Designed and Manufactured I/O Expander GEN-020 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify products

More information

Two Door Controller GEN-045

Two Door Controller GEN-045 Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify

More information

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

genesis TECHNICAL MANUAL Two-Door Controller GEN-045 Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves

More information

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL Revision 2.1 July. 2014 1 Integriti 8 32 Zone LAN Expander Module Kit P/N: 996005PCB&K For Rev. B PCB. INSTALLATION MANUAL Overview The Integriti 8 Zone Expander Module provides an additional 8 Zone inputs,

More information

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications 12 Universal Expander Module. Installation Notes. Revision 1.2 August. 2003. 1 Reporting Reporting with most Contact ID maps will treat the Mini Expander, Exp32 and Exp16 as the same. (With the exception

More information

NETWORK CONCENTRATOR LINK. This equipment must only be installed and serviced by professional qualified personnel.

NETWORK CONCENTRATOR LINK. This equipment must only be installed and serviced by professional qualified personnel. Revised! see Protective Earthing Addendum cback NOTE: This equipment must only be installed and serviced by professional qualified personnel. The Network Concentrator Link is a fully self contained unit

More information

TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual

TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual P/N MAINST-867/869 REV 07 ISS 26NOV13 Copyright Trademarks and patents Manufacturer ACMA compliance Contact information 2013 UTC Fire

More information

installation quick guide integrated access control & environmental monitoring

installation quick guide integrated access control & environmental monitoring installation quick guide integrated access control & environmental monitoring Introduction This Installation Quick Guide is suitable for standard wallmountable AX300 controllers. Illustrative technical

More information

emerge Essential Access Control System

emerge Essential Access Control System emerge Essential Access ontrol System Document Number: 620-100239, Rev. Installation Guide Linear LL 1950 amino Vida Roble, Suite 150 arlsbad, A 92008-6517 www.linearcorp.com Notices All rights strictly

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

Installation Manual. Contents

Installation Manual. Contents CONCEPT IQ. Combined Installation Manual Rev 1.0 05/03 p1 Installation Manual Contents Section One: Concept IQ Hardware Overview 1.1 Typical Installation 1.2 Concept IQ Lockable Cabinet 1.3 Connecting

More information

AX200. Installation Guide

AX200. Installation Guide Axxess Identification Ltd 27-28 Shrivenham Hundred Business Park, Watchfield, Swindon, Wiltshire SN6 8TZ United Kingdom Tel: +44 (0)1793 784002 Fax: +44 (0)1793 784005 Email: info@axxessid.com May 2008

More information

Wiring Guide EP.HIO. Version 1.03 Last Updated:

Wiring Guide EP.HIO. Version 1.03 Last Updated: Wiring Guide EP.HIO Version 1.03 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual Platform1 version 3 support 6 and 10

More information

INPUTS: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)

INPUTS: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup) INPUTS: All inputs: Inputs 1 to 24: Tamper: Panic: Fire: Keyswitch: 16-18VAC: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)

More information

PILOT TONE DETECTION MODULE IMPEDANCE DETECTION MODULE

PILOT TONE DETECTION MODULE IMPEDANCE DETECTION MODULE INSTALLATION MANUAL VX-2000 series PILOT TONE DETETION MODULE IMPEDANE DETETION MODULE VX-200SP-2 VX-200SZ-2 Thank you for purchasing TOA s VX-2000 series plug-in modules. Please carefully follow the instructions

More information

Cardax FT Controller 3000

Cardax FT Controller 3000 Installation Note Cardax FT Controller 000 CAUTION This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any

More information

MR50 READER INTERFACE

MR50 READER INTERFACE 2.75 [69.9] 2.35 [59.7] U1 MR50 READER INTERFAE Installation and Specifications: 1. General: www.mercury-security.com 2355 MIRA MAR AVE. LONG BEAH, A 90815-1755, (562)986-9105 FAX (562) 986-9205 This device

More information

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014 SF200 Installation Guide & Quick Start Guide 2 TFT AC Terminal Version: 1.0 Date: June 2014 All design and specification declared are subject to change without notice in advance. Contents Safety Precautions

More information

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1 15370 Barranca Parkway Irvine, CA 92618 USA VertX V100, V200 and V300 Installation Guide November 2011 6080-930 Rev A.1. Contents Introduction... 3 Parts List... 3 Product Specifications... 3 Cable Specifications...

More information

Installation Instructions

Installation Instructions Installation Instructions Use these instructions to help you: determine the equipment needed for installing the A-B station module install the A-B station module Before installing the A-B station module,

More information

Installing Sentor. Hardware Installation

Installing Sentor. Hardware Installation Remote base site monitoring and control Installing Sentor Hardware Installation Copyright 2000 Sentor Monitoring Systems Pty Ltd Contents: 1 Introduction... 1 2 Sentor GUI... 2 3 ST3000 Controller... 3

More information

INSTALLATION INSTRUCTIONS 923P EntryCheck TM

INSTALLATION INSTRUCTIONS 923P EntryCheck TM 801 Avenida Acaso, amarillo, a. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUTIONS 923P Entryheck TM The Entryheck 923P Indoor/Outdoor Keypad is a surface

More information

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming AC-115 Compact Networked Single- Controller Hardware Installation and Programming Copyright 2013 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to REL,

More information

ACTpro 1500 Single Door IP Controller

ACTpro 1500 Single Door IP Controller ACTpro 1500 Single Door IP Controller ACTpro 1520 Single Door IP Controller with 12 V DC 2 amp power supply. Operating & Installation Instructions 18-00085 Issue 2 This manual refers to the ACTpro 1500

More information

Model 3OOO ACCESS 4000

Model 3OOO ACCESS 4000 Revision 5.0 April. 2004 1 Model 3OOO 0 Cont & ACCESS 4000 Control Module 995001 / 995002 SECURITY, ACCESS CONTROL & BUILDING AUTOMATION SYSTEM INSTALLATION MANUAL OVERVIEW The 3000/Access 4000 provides

More information

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro Single Door IP Controller. Operating & Installation Instructions ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control

More information

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ TR RS -0 0 /5 en - 06 00 RU/, RU/ (RUT /) ontrol and interlock devices rogrammable compact devices for local control, interlock and energy management functions in V systems They may be used for stand-alone

More information

High Level Lift Protocol Controller Model TS0868

High Level Lift Protocol Controller Model TS0868 High Level Lift Protocol Controller Model TS0868 High Level Lift Protocol Controller : Model TS0868 INSTALLATION GUIDE A high level lift protocol interface for the TS0869 Intelligent Four Lift Controller

More information

PR402 v2.0 Installer Manual Rev.C

PR402 v2.0 Installer Manual Rev.C PR402 v2.0 Installer Manual Rev.C Introduction This document contents minimum information required for electrical connections, installation and initial tests of PR402 access controller. Installation The

More information

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL MODEL NUMBER: XRT910-0-0-AC-XX XRT920-0-0-AC-XX AMANO itrt Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power Designed to work

More information

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4 Table of Contents 1 ABOUT THIS GUIDE... 3 1.1 CONTACT INFORMATION... 3 2 ANTENNA INSTALLATION... 4 2.1 GENERAL INFORMATION... 4 2.2 SPECIFIC MOUNTING EXAMPLES... 5 2.3 CONNECTOR MOISTURE PROTECTION...

More information

Pro-Star AVW200 Installation and Operation Manual Protel, Inc. ALL RIGHTS RESERVED AVW200HM01.1

Pro-Star AVW200 Installation and Operation Manual Protel, Inc. ALL RIGHTS RESERVED AVW200HM01.1 Pro-Star AVW200 Installation and Operation Manual 2005 Protel, Inc. ALL RIGHTS RESERVED AVW200 Installation and Operation Manual Revision History Revision Date Description of Changes AVW200HM01.0 12/05

More information

PRO3200 Professional Modular Access Control Hardware

PRO3200 Professional Modular Access Control Hardware PRO3200 Access Control Hardware As a part of the WIN-PAK software controlled hardware family the PRO3200 professional modular access control hardware is an advanced access control panel capable of providing

More information

installation Operation ADDRESS product diagram H8030/8031 INSTALLATION GUIDE

installation Operation ADDRESS product diagram H8030/8031 INSTALLATION GUIDE POWER MONITORING INSTALLATION GUIDE H8030/8031 H8030/8031 Modbus Energy Meter Networked kw/kwh Transducer Product Identification Model Max Amps CT Size Enhanced Data Stream Meters H8030-0100- 100 H8030-0300-

More information

SOFTWARE VERSION 3.10

SOFTWARE VERSION 3.10 738PEP-03 SOFTWARE VERSION 3.10 HEXA PROGRAMMING: Addresses 000 to 043 and 300 to 527 are programmed using the Hexa Programming method. In this mode, you can enter any hexa-digit from 0-F where keys [1]

More information

SMARTLINE WIRELESS INTERFACE SYSTEM INSTALLATION MANUAL

SMARTLINE WIRELESS INTERFACE SYSTEM INSTALLATION MANUAL SMARTLINE WIRELESS INTERFACE SYSTEM INSTALLATION MANUAL SmartLine (Wireless) Installation Manual v1.9 1.Contents 2. Overview...2 Equipment List...2 Introduction... 2 Monitoring Software Compatibility...2

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS www.altroniccontrols.com INSTALLATION INSTRUCTIONS EXACTA 21 MONITORING AND CONTROL SYSTEM CAUTION: The EXACTA 21 CONTROL SYSTEM is CSA CERTIFIED FOR use in Class I, GROUPS C & D, Division 2 hazardous

More information

2-Way Wireless I/O Expander Installation Guide

2-Way Wireless I/O Expander Installation Guide 2-Way Wireless I/O Expander Installation Guide For more detailed information please refer to the iconnect Installer Manual provided on our website: www.electronics-line.com Table of Contents 1. Introduction...

More information

PRO2200 Professional Modular Access Control Hardware

PRO2200 Professional Modular Access Control Hardware PRO2200 Access Control Hardware As a part of the WIN-PAK software controlled hardware family the PRO2200 professional modular access control hardware is an advanced access control panel capable of providing

More information

HYDROTHUNDER WIRING & CIRCUIT INFORMATION C H A P T E R F I V E

HYDROTHUNDER WIRING & CIRCUIT INFORMATION C H A P T E R F I V E HYDROTHUNDER C H A P T E R F I V E WIRING & CIRCUIT INFORMATION WARNING: Failure to reconnect all ground wires or to replace metal shields and covers with each mounting screw installed and securely tightened

More information

istar Pro Installation Guide

istar Pro Installation Guide istar Pro Installation Guide UM-241 Version A1 October 2010 istar Pro Installation Quick Start Guide System Components The istar Pro hardware components consist of: General Controller Module (GCM) A general

More information

MCM Electronics MCM Electronics MCM Electronics. The Icon Series. Installation and Programming Information. Icon 8 Version 5.0

MCM Electronics MCM Electronics MCM Electronics. The Icon Series. Installation and Programming Information. Icon 8 Version 5.0 MCM Electronics MCM Electronics MCM Electronics The Icon Series Installation and Programming Information Icon 8 Version 5.0 TABLE OF CONTENTS 1. 2. 3. Panel Hardware Page 2 Physical Layout. Inputs. Outputs.

More information

PW6000 Modular Access Control System PW6000 Intelligent Controllers and Modules

PW6000 Modular Access Control System PW6000 Intelligent Controllers and Modules Modular Access Control System The next generation of the PW-Series family improves on the existing PW technology to offer superior features and benefits. The PW-Series Modular Control System is an advanced

More information

16-Way Input 48-Way Output Card

16-Way Input 48-Way Output Card 16-Way Input 48-Way Output Card Features 16 Configurable Inputs Push Button, Switch Input Fast Input Response 48 Configurable Outputs OFF, ON, 0.5S ON / 0.5S OFF, 1S ON / 1S OFF Configurable Buzzer OFF,

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

IQ21x Series Controllers

IQ21x Series Controllers IQ1x Series Controllers IQ1x SERIES CONTROLLERS Description Features The IQ1x series of intelligent controllers are designed for use as unitary controllers in building control systems. Full compatibility

More information

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND

More information

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions 3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These

More information

Universal Expander Module in Low Profile Enclosure. P/N: INSTALLATION MANUAL

Universal Expander Module in Low Profile Enclosure. P/N: INSTALLATION MANUAL Revision 2.14 October. 2009 1 Overview Universal Module in Low Profile Enclosure. P/N: 995004 INSTALLATI MANUAL The Universal Module connects to a Model 3000/Access 4000 system OR a Model 2000 system,

More information

Revision 1.4 October Integriti. Security Controller (ISC) SECURITY, ACCESS CONTROL & AUTOMATION SYSTEM INSTALLATION MANUAL

Revision 1.4 October Integriti. Security Controller (ISC) SECURITY, ACCESS CONTROL & AUTOMATION SYSTEM INSTALLATION MANUAL Revision 1.4 October. 2016. 1 Integriti Security Controller (ISC). 996001 0 Cont SECURITY, ACCESS CONTROL & AUTOMATION SYSTEM INSTALLATION MANUAL Contents PARTS LIST...2 INSTALLATION INSTRUCTIONS...2-4

More information

MCX402DR-BRD I/O expander. Operating Manual

MCX402DR-BRD I/O expander. Operating Manual Roger Access Control System MCX402DR-BRD I/O expander Operating Manual Product version: 1.0 Firmware version: 1.0.2.255 Document version: Rev. B Design and application The MCX402DR-BRD is I/O expander

More information

IQ22x Series Controllers

IQ22x Series Controllers IQx Series ontrollers IQx SERIES ONTROLLERS Description Features Medium size controller with extremely versatile I/O capability suitable for a broad range of applications, especially in the area of dedicated

More information

REX F-0-9 Standalone or Access Controller

REX F-0-9 Standalone or Access Controller REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes

More information

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Digi-modems. Issue 3

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Digi-modems. Issue 3 THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL Digi-modems Issue 3 Contents Com300 & Com2400 Installation Manual Contents 1. Regulatory Requirements... 3 General...3 Approval... 3 REN Rating... 3 2.

More information

SPMS SmartPage Messaging System

SPMS SmartPage Messaging System A division of NESS CORPORATION PTY LTD SPMS SmartPage Messaging System INSTALLATION AND USER MANUAL SmartPage Installation and User Manual V1.4 1. Contents 1. Contents... 1 2. Overview... 2 Introduction...

More information

Second Encoder Option Card for PowerFlex 700S Drives with Phase II Control

Second Encoder Option Card for PowerFlex 700S Drives with Phase II Control Installation Instructions Second Encoder Option ard for PowerFlex 700S Drives with Phase II ontrol!!! TTENTION: To avoid an electric shock hazard, verify that the voltage on the bus capacitors has discharged

More information

DVAA Series Disk Array for DVR1 Series Digital Video Recorder

DVAA Series Disk Array for DVR1 Series Digital Video Recorder DVAA Series Disk Array for DVR1 Series Digital Video Recorder Eng Installation Instructions Philips Communication, Security & Imaging Warning! To prevent fire and electronic shock, do not expose this product

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V130 COM Modules: V100-17-CAN, V100-17-RS4/X, V100-17-ET2 This guide shows you how to install an additional communication module in a V130 controller. Instructions and technical specifications

More information

SPX Supervised Reader Extender. Wiring Diagram and Operators Manual MAN-FA-SPX-1200 V1.03

SPX Supervised Reader Extender. Wiring Diagram and Operators Manual MAN-FA-SPX-1200 V1.03 SPX-1200 Supervised eader Extender Wiring Diagram and Operators Manual MAN-FA-SPX-1200 V1.03 2005 ypress omputer Systems,Inc. www.cypressworld.com Page 1 Table of ontents Quick eference guides Page 3,4

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Distributed By: INSTALLATION INSTRUCTIONS Product Revision Form Rev. H PANASONIC CF19 DOCKING STATIONS, CRADLE and ACCESSORIES 7160-0207: Docking Station (NO/RF) 7160-0215: LED Assembly 7160-0207-02: Docking

More information

UniStream CPU-for-Panel

UniStream CPU-for-Panel UniStream CPU-for-Panel Installation Guide USC-P-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This guide provides basic

More information

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02 1/8 NRK16/A, NRK16-B/A, (NRK16-T /A, NRK14-T /A, NRK16-WEB/A) Control and interlock devices with pre-programmed system-specific application modules The controllers may be used as stand-alone control and

More information

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000 Technical Specification Sheet Rev. 6, March, 2000 Unitary Controller The Unitary Controller can operate as an independent stand-alone controller, or can be connected to the APOGEE Automation System via

More information

TAC I/NETTM 1284, 1280, Security Control Unit

TAC I/NETTM 1284, 1280, Security Control Unit TAC I/NETTM The SCU () family of modular, stand-alone controllers are basic building blocks of the I/NET Seven Security Management System, and provide a flexible mix of door control and alarm monitoring

More information

Installation Manual for D244X Series 24-volt Power Supplies

Installation Manual for D244X Series 24-volt Power Supplies Installation Manual for D244X Series 24-volt Power Supplies D2441-B D2441-C D2443-B D2443-C D2445-B D2445-C D2400 Series 1A 24 volts 1A 24 volts 3A 24 volts 3A 24 volts 5A 24 volts 5A 24 volts Dycon Power

More information

Network Design and Setup

Network Design and Setup 2 3 2 hoosing the onfiguration nalyze your pplication There are almost as many ways to build your network as there are grains of sand at the beach. The first step in determining the configuration is to

More information

CP150B Vandal & Weather Resistant Keypad Security Systems

CP150B Vandal & Weather Resistant Keypad Security Systems Vandal & Weather Resistant Keypad Security Systems EN Security System CP150B - Vandal & Weather Resistant Keypad The CP150B keypad provides alarm and or access control functionality when used on selected

More information

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new Controller.

More information

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09 CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.

More information

Safecom Solution-16 Quick Reference Guide ISSUE 1.10

Safecom Solution-16 Quick Reference Guide ISSUE 1.10 Safecom Solution-16 Quick Reference Guide ISSUE 1.10 2 Solution-16 Safecom Quick Reference Guide Safecom Solution-16 Quick Reference Guide Copyright 1998 by, SYDNEY, AUSTRALIA Document Part Number MA8016Q

More information

EAP 300 REMOTE ANNUNCIATOR INSTALLATION MANUAL. r.0454a

EAP 300 REMOTE ANNUNCIATOR INSTALLATION MANUAL. r.0454a EAP 300 REMOTE ANNUNCIATOR INSTALLATION MANUAL r.0454a PM084 Rev 0 08/06/20 9087A 198 th Street, Langley, BC Canada V1M 3B1 Telephone (604) 888-0110 Telefax (604) 888-3381 E-Mail: info@thomsontechnology.com

More information

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated:

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated: Wiring Guide EP.L3800 Version 1.03 Last Updated: 13-10-2014 1 Note: L3800 is the serial enabled lift controller. L3800 will ship with a HIO board in a package which can cater up to 8 floors. It can connect

More information

Sigma Si. Extinguishant Status Unit (K , K , K , K , K , K , K , K )

Sigma Si. Extinguishant Status Unit (K , K , K , K , K , K , K , K ) Sigma Si Extinguishant Status Unit (K91100055, K91100056, K91110055, K91110056, K91111055, K91111056, K91111355, K91111356) Operation and Maintenance Manual Man1089 Issue 07 June 2013 Index Section Page

More information

SAFETY PRECAUTIONS CAUTION WARNING CAUTION. Thank you for purchasing ig5a Series Profibus Communication Module

SAFETY PRECAUTIONS CAUTION WARNING CAUTION. Thank you for purchasing ig5a Series Profibus Communication Module SAFETY PRECAUTIONS Thank you for purchasing ig5a Series Profibus Communication Module SAFETY PRECAUTIONS Always follow safety instructions to prevent accidents and potential hazards from occurring. Safety

More information

Model 2657A-LIM-3 LO Interconnect Module

Model 2657A-LIM-3 LO Interconnect Module Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 2657A-LIM-3 LO Interconnect Module User's Guide Description The Model 2657A-LIM-3 LO Interconnect

More information

Sigma-XT-ECU-LCS Extinguishant Control Unit Local Control Station Operation and Maintenance Manual

Sigma-XT-ECU-LCS Extinguishant Control Unit Local Control Station Operation and Maintenance Manual SigmaXTECULCS Extinguishant Control Unit Local Control Station Operation and Maintenance Manual SigmaXTECULCS Issue 1 October 2011 Index Section Page 1 Introduction... 3 2 Safety and mounting... 3 2.1

More information

Enercept H8035/H8036 Modbus Energy Meter Networked kw/kwh Transducers

Enercept H8035/H8036 Modbus Energy Meter Networked kw/kwh Transducers POWER MONITORING INSTALLATION GUIDE Enercept H8035/H8036 Modbus Energy Meter Networked kw/kwh Transducers US Patent No. 6,373,238 Installer's Specifications Input Voltage 208 to 480 VAC Number of Phases

More information

9500 and 9600 I/O Card Installation Instructions

9500 and 9600 I/O Card Installation Instructions 9500 and 9600 I/O Card Installation Instructions This document describes how to install, configure, and verify the operation of the optional Input/Output card ( I/O card ) into your 9500 or 9600 power

More information

MX200 SERIES Modbus Card 50P GE Zenith Controls. Operation and Maintenance Manual 50R-2200B 12/00

MX200 SERIES Modbus Card 50P GE Zenith Controls. Operation and Maintenance Manual 50R-2200B 12/00 g MX200 SERIES Modbus Card 50P-1105 GE Zenith Controls 50R-2200B 12/00 Operation and Maintenance Manual Table of Contents Overview...01 Page LED Indicator...02 Installation...03 Installing the Network

More information

PRT-RDS2 Standard 2 Reader Expander

PRT-RDS2 Standard 2 Reader Expander PRT-RDS2 Standard 2 Reader Expander Installation Manual CONTENTS Protégé System... Introduction... Reader Expander... Features... Reader Expander Specifications... Protégé System Management Suite... Protégé

More information

Resolver to Digital Expansion Board

Resolver to Digital Expansion Board Resolver to Digital Expansion Board Catalog No. EXB009A01 Installation and Operating Manual 6/98 MN1313 Table of Contents Section 1 General Information............................. 1-1 Introduction....................................

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TT-40 9/0 INSTALLATION INSTRUCTIONS Original Issue Date: 9/0 Model: Automatic Transfer Switches Equipped with the Programmable Controller Market: ATS Subject: External Battery Supply Module Kit GM69-KP

More information

DS BAS /99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER FEATURES

DS BAS /99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER FEATURES DS 13.321 BAS 2800+ 06/99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER Specification no. 579-1-904 The Universal Network Controller (UNC 596) is fully intelligent and incorporates its

More information

JVA Z Series Keypad Bus Wiring Installation Manual

JVA Z Series Keypad Bus Wiring Installation Manual JVA Z Series Keypad Bus Wiring Version: 1.21 Date: 1 June 2015 By: Miles Norton JVA Technologies Pty Ltd 2013 Version July 2013. Uncontrolled if printed Introducing the Keypad Bus Table of Contents 1 Introducing

More information

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM 80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount

More information

Installation Instructions

Installation Instructions Installation Instructions This document provides information on: important pre-installation considerations power supply requirements initial handling procedures installing the module using the indicators

More information

* * ARM MONITOR EXCLUDE MEMORY. HomeSafe Security Panel 5400/16CB. Programming Manual C-Bus Supplement

* * ARM MONITOR EXCLUDE MEMORY. HomeSafe Security Panel 5400/16CB. Programming Manual C-Bus Supplement * * ARM 1 2 3 MONITOR 4 5 6 EXCLUDE 7 8 9 MEMORY P 0 E HomeSafe Security Panel 5400/16CB Programming Manual C-Bus Supplement Contents 1.0 Product Range...3 2.0 Features...3 2.1 Control Panel Features...3

More information

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.

More information

PowerLogic ION7550 / ION7650 Hardware Lockable Meter

PowerLogic ION7550 / ION7650 Hardware Lockable Meter 70052-0194-01 PRODUCT OPTION 11/2006 PowerLogic ION7550 / ION7650 Hardware Lockable Meter This document provides an overview of ION7550 and ION7650 hardware lockable meters. NOTE Industry Canada approval

More information

Installation Instructions

Installation Instructions Installation Instructions (1771-ODD Series B) Use this document as a guide when installing the catalog number 1771-ODD series B output module. The ac isolated output module is shipped in static-shielded

More information

Installation Instructions

Installation Instructions Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line

More information

Installation Instructions

Installation Instructions Installation Instructions This document provides information on: important pre-installation considerations power supply requirements initial handling installing the module using the indicators for troubleshooting

More information

POWERHOUSE. -- the finest in Digital Command Control -- PRODUCT MANUAL FOR PB-205a DUAL 5AMP POWER STATION

POWERHOUSE. -- the finest in Digital Command Control -- PRODUCT MANUAL FOR PB-205a DUAL 5AMP POWER STATION POWERHOUSE TM -- the finest in Digital Command Control -- PRODUCT MANUAL FOR PB-205a DUAL 5AMP POWER STATION NCE Corporation 1260 CREEK STREET SUITE 100 WEBSTER NEW YORK 14580 FAX : (716) 671-9337 E-mail:

More information

Allen-Bradley Motors

Allen-Bradley Motors Installation Instructions Firmware Update Instructions for Ethernet, Enhanced and ControlNet PLC-5 Programmable Controllers Purpose Firmware Update Kit Contents Hardware and Software Requirements This

More information

Fibre Modem - Single-mode

Fibre Modem - Single-mode Revision 1.0 November. 2006 1 - Single-mode P/N: : 995087 Model 3000 / Access 4000 Optically Isolated Interface INSTALLATION GUIDE OVERVIEW: The Inner Range Single-mode provides 2 separate, optically isolated

More information

POCKET MULTIMETER Model No: MM18

POCKET MULTIMETER Model No: MM18 INSTRUCTIONS FOR: POCKET MULTIMETER Model No: MM18 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained,

More information