Standard actuator 440K-A Standard actuator 440G-A Fully flex actuator 440G-A07269

Size: px
Start display at page:

Download "Standard actuator 440K-A Standard actuator 440G-A Fully flex actuator 440G-A07269"

Transcription

1 Safety Interlock Overview 1 Product Selection Description Elf Cadet 3 T15 T15 GD T5T6 T5 GD T6 GD MTGD TLS GD Atlas 5 440G MT actuator 440KA11095 actuator 440KA1138 actuator 440GA07136 GD standard actuator Flat actuator, not to be used with metal alignment guide 440GA KA1014 GD flat actuator 440KA actuator, not to be used with metal alignment guide 440KA1006 Fully flex actuator 440GA7143 Fully flex actuator 440GA0769 Extended flat actuator Metal alignment guide with semiflexible actuator Alignment guide with semiflexible actuator 440KA KA KA11144 Alignment guide with fullyflexible actuator Catch and Retainer Kit Replacement Alignment Guide 440KA KA KA Visit our website:

2 Safety Tongue Elf Product Selection Safety Auxiliary Action Actuator Type M16 1 N.C. 1 N.O. N.C. Recommended s M16 Conduit 1/ inch NPT Adaptor Distribution Box 4Pin Micro (M1) Connector ArmorBlock Guard I/O 5Pin Micro (M1) Flat 440KE KE KE KE KE KE3305 GD Metal alignment guide w/semiflex actuator 440KE KE KE KE KE KE33076 Flat 440KE KE KE KENNFPS KE KE KE3304 GD Metal alignment guide w/semiflex actuator 440KE KE KENNAPS 440KE KE33079 For connector ratings see page 39. With a 5pin micro (M1) connector, not all contacts are connected. See Typical Wiring Diagram on page 313 for wiring details. Description Safety Outputs Auxiliary Outputs Terminals Reset Type Supply Cat. Page No. SingleFunction Safety Relays for N.C. Switch MSR17RP 3 N.O. 1 N.C. Removable (Screw) 4V AC/DC RN3135 MSR17TP 3 N.O. 1 N.C. Removable (Screw) Auto./Manual 4V AC/DC RN313 MSR30RT N.O. Solid State 1 N.O. Solid State Removable SingleFunction Safety Relays for 1 N.C. & 1 N.O. Switch Auto./Manual or 4V DC RN3198 MSR9T N.O. 1 N.C. Fixed Auto./Manual 4V AC/DC RF307 MSR33RT N.O. Solid State 1 N.O. Removable Modular Safety Relays MSR10P Base N.C. only MSR0P Input Module MSR310P Base MSR30P Input Module N.O. 1 N.C. and PNP Solid State Removable Auto. or Monitored Manual Auto./Manual or 4V DC SELV RF300 4V DC from the base unit RH3176 Removable 4V DC RH3178 MSR300 Series Output Modules 3 PNP Solid State Removable Auto./Manual PNP Solid State Removable 4V DC RW319 4V DC from the base unit Note: For additional Safety Relays connectivity, see the Safety Relays section (page 58) of this catalog. For additional Safety I/O and Safety PLC connectivity, see the Programmable Safety System section (page 5107) of this catalog. For application and wiring diagrams, see the Safety Applications section (page 101) of this catalog RW318 1 Connection Systems Description Connection to Distribution Box 4Pin Micro (M1) Connection to ArmorBlock Guard I/O 5Pin Micro (M1) 1 N.C. & 1 N.O. N.C. N.C. Cordset 889DF4AC 889DF4AC Patchcord 889DF4ACDM 889DF4ACDM 889RF5ECRM Distribution Box 898DP4 KTDM4 898D4 LTDM4 Shorting Plug 898D41KUDM 898D41LUDM TPort 898D43KYD4 898D43LYD4 Replace symbol with ( m), 5 (5 m), or 10 (10 m) for standard cable lengths. Replace symbol with 1 (1 m), ( m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths. Replace symbol with 4 or 8 for number of ports. Note: For additional information, see the Safety Connection System section (page 71) of this catalog. 311

3 Safety Tongue Elf Description Dimensions 1 Approximate Dimensions Flat actuator, not to be used with metal alignment guide KA actuator, not to be used with metal alignment guide KA1006 Metal alignment guide with semiflexible actuator KA1030 Metal Alignment Guide KA1069 Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes. Replacement Cover 440AA33085 Dust Cover 440KA (.95) 5 (0.98) 31 Visit our website:

4 Safety Tongue Cadet 3 Product Selection Safety Auxiliary Action 3 N.C. N.C. 1 N.O. Recommended s MBB Actuator Type M16 M16 Conduit 1/ inch NPT Adaptor Distribution Box 6Pin Micro (M1) Connector ArmorBlock Guard I/O 5Pin Micro (M1) Flat 440KC KC KC KCNNFPS KC KC KC1091 GD Metal alignment guide w/semiflex actuator 440KC KC KCNNAPS 440KC1070 Flat 440KC KC KC KC KC KC1067 GD Metal alignment guide w/semiflex actuator 440KC KC KC1055 Flat 440KC KC KC KC KC KC1068 GD Metal alignment guide w/semiflex actuator 440KC KC KC1080 For connector ratings see page 39. With a 5pin micro (M1) connector, not all contacts are connected. See Typical Wiring Diagram on page 317 for wiring details. Description Safety Outputs Auxiliary Outputs Terminals Reset Type Supply Cat. Page No. SingleFunction Safety Relays MSR17RP 3 N.O. 1 N.C. Removable (Screw) 4V AC/DC RN3135 MSR17TP 3 N.O. 1 N.C. Removable (Screw) Auto./Manual 4V AC/DC RN313 MSR16T N.O. None Fixed Auto./Manual 4V AC/DC 5 440RN3117 MSR30RT N.O. Solid State 1 N.O. Solid State Removable Modular Safety Relays MSR10P Base N.C. only MSR0P Input Module MSR310P Base MSR30P Input Module N.O. 1 N.C. and PNP Solid State Removable Auto./Manual or Auto./Manual or 4V DC RN3198 4V DC from the base unit RH3176 Removable 4V DC RH3178 MSR300 Series Output Modules 3 PNP Solid State Removable Auto./Manual PNP Solid State Removable 4V DC RW319 4V DC from the base unit Note: For additional Safety Relays connectivity, see the Safety Relays section (page 58) of this catalog. For additional Safety I/O and Safety PLC connectivity, see the Programmable Safety System section (page 5107) of this catalog. For application and wiring diagrams, see the Safety Applications section (page 101) of this catalog RW318 1 Connection Systems Description 6Pin Micro (M1) 5Pin Micro (M1) Cordset 889RF6ECA Patchcord 889RF6ECRM 889RF5ECRM Distribution Box 898RP68MTA5 Shorting Plug 898RP61MURM TPort NA Replace symbol with ( m), 5 (5 m), or 10 (10 m) for standard cable lengths. Replace symbol with 1 (1 m), ( m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths. Note: For additional information, see the Safety Connection System section (page 71) of this catalog. 315

5 & Safety Tongue Cadet 3 Description Dimensions 1 Approximate Dimensions Flat actuator, not to be used with metal alignment guide 90 actuator, not to be used with metal alignment guide Metal alignment guide with semiflexible actuator Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes. # $ ' ( ) ' ( * KA KA KA1030 Replacement Cover 440AA1115 Dust Cover 440KA1718! " # $ % Note: D, 3D and electrical drawings are available on Visit our website:

6 Safety Tongue Trojan T15 Product Selection Type Trojan T15 Trojan T15 GD Safety Auxiliary Action Actuator Type M0 N.C. 1 N.C. 1 N.O. N.C. 1 N.C. 1 N.O. M0 Conduit 1/ inch NPT Adaptor Distribution Box 4Pin Micro (M1) Connector ArmorBlock Guard I/O 5Pin Micro (M1) 440KT KT KT KVNNSPS Fully 440KT KT KT KVNNBPS 440KT KT KT KT KT11386 Fully 440KT KT KT KT KT11388 GD 440KT KT KT KVNNGPSNG Fully 440KT KT KT KT KT11391 GD 440KT KT KT1139 Fully 440KT KT KT KT KT For connector ratings see page 39. Recommended s Description Safety Outputs Auxiliary Outputs Terminals Reset Type Supply Cat. Page No. SingleFunction Safety Relays for N.C. Switch MSR17RP 3 N.O. 1 N.C. Removable (Screw) 4V AC/DC RN3135 MSR17TP 3 N.O. 1 N.C. Removable (Screw) Auto./Manual 4V AC/DC RN313 MSR30RT N.O. Solid State 1 N.O. Solid State Removable SingleFunction Safety Relays for 1 N.C. & 1 N.O. Switch Auto./Manual or 4V DC RN3198 MSR9T N.O. 1 N.C. Fixed Auto./Manual 4V AC/DC RF307 MSR33RT N.O. Solid State 1 N.O. Removable Modular Safety Relays MSR10P Base N.C. only MSR0P Input Module MSR310P Base MSR30P Input Module N.O. 1 N.C. and PNP Solid State Removable Auto. or Monitored Manual Auto./Manual or 4V DC SELV RF300 4V DC from the base unit RH3176 Removable 4V DC RH3178 MSR300 Series Output Modules 3 PNP Solid State Removable Auto./Manual PNP Solid State Removable 4V DC RW319 4V DC from the base unit Note: For additional Safety Relays connectivity, see the Safety Relays section (page 58) of this catalog. For additional Safety I/O and Safety PLC connectivity, see the Programmable Safety System section (page 5107) of this catalog. For application and wiring diagrams, see the Safety Applications section (page 101) of this catalog RW318 Connection Systems Description Connection to Distribution Box 4Pin Micro (M1) Connection to ArmorBlock Guard I/O 5Pin Micro (M1) N.C. 1 N.C. & 1 N.O. N.C. Cordset 889DF4AC 889DF4AC Patchcord 889DF4ACDM 889DF4ACDM 889DF5ACDM Distribution Box 898D4 LTDM4 898DP4 KTDM4 Shorting Plug 898D41LUDM 898D41KUDM TPort 898D43LYD4 898D43KYD4 Replace symbol with ( m), 5 (5 m), or 10 (10 m) for standard cable lengths. Replace symbol with 1 (1 m), ( m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths. Replace symbol with 4 or 8 for number of ports. Note: For additional information, see the Safety Connection System section (page 71) of this catalog. 319

7 , ,,1,1, Safety Tongue Trojan T15 Description To Be Used With: Dimensions 1 actuator Trojan T15 Models Only KA1138 GD standard actuator Trojan GD Models Only GA7011 GD flat actuator Trojan GD Models Only 440KA Alignment guide with semiflexible actuator Discard Alignment Guide for GD Models 440KA11144 Alignment guide with fullyflexible actuator Discard Alignment Guide for GD Models KA7010 Sliding bolt actuator Trojan GD Models Only GA7163 Catch and Retainer Kit Trojan T15 Models Only KA11094 Replacement Cover All Models 440AA11499 Dust Cover All Models 440KA17180 Approximate Dimensions Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes. 3, / 3 / 61. /, / 8 9 : ; ; < = >8? ; > ; < = >8 9 : 8 = A B 8 Note: D, 3D and electrical drawings are available on 01,. / 3 / D F < = > >G < D D? G D < D > F D? E ; < 8 > H ;? 3 /,1,. / 3 / 3 / / 8 = > ; < = > C D? D ; > E ; < = > F 8? 30 Visit our website:

8 Safety Tongue Trojan 5 & 6 Product Selection Type Trojan 5 Trojan 5 GD Type Trojan 6 Trojan 6 GD Safety Auxiliary Action Actuator Type M0 N.C. 1 N.O. M0 Conduit Connector Safety Auxiliary Action Actuator Type M0 1/ inch NPT Adaptor 8Pin Micro (M1) 3 N.C. 1 N.O. N.C. N.O. 3 N.C. 1 N.O. N.C. N.O. Gold s MBB MBB 440KT KT KT KT KT KT KT KT KW1BNPH MBB 440KT KT KW1MNPH GD 440KT KT KT KT11444 MBB 440KT KT11457 M0 Conduit 1/ inch NPT Adaptor Distribution Box 6Pin Micro (M1) Connector GD 440KT KT1145 ArmorBlock Guard I/O 5Pin Micro (M1) 440KT KT KT1105 Guide/Semi Guide/Fully 440KT KT KT KT KT KT KTNNBPS 440KT KT KT KT KT KT114 Guide/Semi Guide/Fully 440KT KT KT KT KT KT KT KT KT11365 GD 440KT KT KT KTNNGPSNG Guide/Semi Guide/Fully 440KT KT KT KT KT KT KT KT116 GD 440KT KT KT11369 Guide/Semi Guide/Fully 440KT KT KT KT KT KT KT KT1137 Trojan 5 30 N 440KT KT KT1149 For connector ratings see page 39. With a 5pin micro (M1) connector, not all contacts are connected. See Typical Wiring Diagram on page 37 for wiring details. 440KT KT KW1BNPHNG MBB 440KT KT KW1MNPHNG For connector ratings see page 39. With an 8pin micro (M1) connector, not all contacts are connected. See Typical Wiring Diagram on page 37 for wiring details. 1 33

9 Safety Tongue Trojan 5 & 6 Description To Be Used With: Dimensions actuator Trojan T5 and T6 Models Only KA11095 GD standard actuator GD Models Only GA7011 GD flat actuator GD Models Only KA Alignment guide with semiflexible actuator Discard Alignment Guide for GD Models KA11144 Alignment guide with fullyflexible actuator Discard Alignment Guide for GD Models KA7010 Sliding bolt actuator GD Models Only GA7163 Catch and Retainer Kit Trojan T5 and T6 Models Only KA11094 Replacement Cover Trojan T5 Models Only Trojan T5 GD Trojan T6 Models Only Trojan T6 GD 440AA AA AA AA11498 Dust Cover All Models 440KA

10 Safety Tongue MTGD Product Selection Red Body Type MTGD MTGD Latch Release Actuator Safety Auxiliary Action Type M0 1/ in NPT 1Pin M3 3 N.C. 1 N.O. N.C. N.O. 3 N.C. 1 N.O. N.C. N.O. Conduit Connector 8Pin Micro (M1) ArmorBlock Guard I/O 5Pin Micro (M1) 440KMT KMT KMT55094 GD Fully ible 440KMT KMT KMT KMT KMT KMT55096 MBB 440KMT KMT KMT KMT KMT KMT KM1BNDH GD Fully ible 440KMT KMT KMT KMT KMT KMT55099 MBB 440KMT KMT KMT55101 Snap Acting 440KMANDT 440KMANDL 440KM1ANDH 440KMNNNDS Extende d Flat GD Fully ible 440KMAEDM 440KMAEDT 440KMASDM 440KMASDT 440KMABDM 440KMABDT 440KMT KMT KMT5504 GD Fully ible 440KMT KMT KMT KMT KMT KMT55103 MBB 440KMT KMT KMT KMT KMT KMT KM1BNDHN5 440KMNNNDSN5 GD Fully ible 440KMT KMT KMT KMT KMT KMT5505 MBB 440KMT KMT KMT KM1MNDHN5 1 For connector ratings see page 39. With a 5pin micro (M1) connector, not all contacts are connected. See Typical Wiring Diagram on page 33 for wiring details. With an 8pin micro (M1) connector, not all contacts are connected. See Typical Wiring Diagram on page 33 for wiring details. Yellow Body Type Safety Auxiliary Action Actuator Type 1/ in NPT 1Pin M3 MTGD N.C. N.O. Snap Acting Conduit Connector 5Pin Micro (M1) 440KMANYT Extended Flat 440KMAEYT 440KMAEYL 440KMNAEYS N.C. N.O. MBB 440KMMNYTN5 440KMNNNYSN5 For connector ratings see page 39. With a 5pin micro (M1) connector, not all contacts are connected. See Typical Wiring Diagram on page 33 for wiring details. With an 8pin micro (M1) connector, not all contacts are connected. See Typical Wiring Diagram on page 33 for wiring details. 39

11 Safety Tongue MTGD Description Dimensions GD standard actuator GA7011 GD flat actuator KA1111 Fully flex actuator GA Sliding bolt actuator GA7163 Extended flat actuator KA17116 Dust Cover 440KA17180 Approximate Dimensions Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes. MTGD Latch Release 4 x M5 MTGD 11.5 (0.45) 60 (.36) 5 (0.) 8.75 (0.34) 40 (1.57) 30 (1.18) 119 (4.68) (4.66) (0.86) 40 (1.57) 30 (1.18) 0.5 (0.81) 38 (1.5) 10.5 (0.41) 60 (.36) 10.4 (4.03) 4.6 (0.97) 10.5 (0.41) 43 (1.69) (4.59) 30.8 (1.1) 40.7 (1.6) 30.8 (1.1) 9. (0.36) 5 (0.) 43 (1.69) 51 (.0) 67.6 (.66) 74.6 (.93) 30.8 (1.1) 9. (0.36) 5 (0.) 1 x M0, 1 x 1/" NPT 0.5 (0.81) 8.75 (0.34) 1 x M0, 1 x 1/" NPT 0.5 (0.81) 8.75 (0.34) Note: D, 3D and electrical drawings are available on 331

12 I Safety Guard Locking 440GMT 1 Connection Systems Cordset Patchcord Replace symbol with ( m), 5 (5 m), or 10 (10 m) for standard cable lengths. Replace symbol with 1 (1 m), ( m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths. Replace symbol with 0M3, (0.3 m), 0M6 (0.6 m), 1 (1 m), ( m) or 3 (3 m) for standard lengths. Note: For additional information, see page 71. Description 8Pin Micro 1Pin M3 Description Dimensions GD standard actuator GD flat actuator Fully flex actuator Sliding bolt actuator Extended flat actuator Replacement Cover, No LED, No Override Key Replacement Cover, LED, Override Key Emergency Override Key (See Warning below.) DF8AB 889MF1AH 889DF8ABDM 889MF1AHMU 440GA KA GA GA KA GMT GMT GA3606 Dust Cover 440KA17180 WARNING: Do not attach the Emergency Override Key to the 440GMT switch. Approximate Dimensions Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes. Note: D, 3D and electrical drawings are available on Visit our website:

13 I Safety Guard Locking TLSGD Description Dimensions GD standard actuator GA7011 GD flat actuator KA1111 Extended flat actuator KA Fully flex actuator GA7143 Sliding bolt actuator not to be used with the Escape Release GA7163 Cover for TLS1 with external override key for series D and earlier 440GA7140 Cover for TLS3 with external override key for series D and earlier 440GA714 Cover for TLS1 with override key attached for series D and earlier 440GA707 Cover for TLS3 with override key attached for series D and earlier 440GA708 Cover for TLS1 with external override key for series E and later 440GA7371 Cover for TLS3 with external override key for series E and later 440GA737 Cover for TLS1 with override key attached for series E and later 440GA7373 Cover for TLS3 with override key attached for series E and later 440GA7374 Emergency Override Key (See Warning below.) ible Release 1 m (3.8 ft) Cable 440GA GA7356 ible Release 3 m (9.84 ft) Cable GA7357 Dust Cover 440KA17183 Sliding Bolt KAMDS Mounting Plate KAMDSSMPB WARNING: Do not attach the Emergency Override Key to the TLSGD switch. 343

Tongue Switches Visit our website: Interlock. Switches. Safety Switches. Trojan 5 & 6. Specifications.

Tongue Switches Visit our website: Interlock. Switches. Safety Switches. Trojan 5 & 6. Specifications. 1-2 -Interlock Safety 4 Description The Trojan family is a universal tongue-operated (or key-operated) safety-interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards.

More information

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs Safety Contacts Direct Opening Action. Operating Radius, Min

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs Safety Contacts Direct Opening Action. Operating Radius, Min AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr Safety Tongue Cadet 3 General 1-2-Opto-electronics

More information

3-6. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Interlock Switches Overview.

3-6. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Interlock Switches Overview. Safety Interlock Overview General 1-2-Opto-electronics 3-Interlock Versatility Many safety switches allow the head of the switch to rotate, offering different options on how the switch can be operated

More information

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs Safety Contacts Direct Opening Action. Operating Radius, Min

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs Safety Contacts Direct Opening Action. Operating Radius, Min AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr Safety Tongue Elf General 1-2-Opto-electronics

More information

3-6. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Interlock Switches Overview.

3-6. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Interlock Switches Overview. Safety Interlock Overview 1-2-Opto-electronics 3-Interlock Versatility Many safety switches allow the head of the switch to rotate, offering different options on how the switch can be operated and mounted

More information

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Auxiliary Contacts

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Auxiliary Contacts AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr Safety Tongue Description The family is a robust,

More information

3-14. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Tongue Switches Cadet 3.

3-14. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Tongue Switches Cadet 3. General 1-2-Opto-electronics 3-Interlock Description The Cadet 3 is a tongue-operated (or key-operated) safety interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards.

More information

Safety Switches 3-1. General. 3-Interlock. Switches. Operator. Interface. Logic. Power. Safety Switches Table of Contents. 2-Opto-electronics

Safety Switches 3-1. General. 3-Interlock. Switches. Operator. Interface. Logic. Power. Safety Switches Table of Contents. 2-Opto-electronics Safety Table of Contents Selection Criteria Selection Flowchart... 3-2 Selection Tips... 3-3 Technology Overview... 3-4 Interlock Overview Versatility... 3-6 Accessories for Tongue and Guard Locking...

More information

Tongue Switches Trojan 5 & 6

Tongue Switches Trojan 5 & 6 Interlock Switches Description The Trojan family is a universal tongue (or key) actuated safety interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards. The dual key

More information

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs. Safety Contacts. Auxiliary Contacts

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs. Safety Contacts. Auxiliary Contacts Safety TLS- General 1-2-Opto-electronics 3-Interlock Logic Description The TLS- is a positive mode, tongue operated guard locking interlock switch that locks a machine guard closed until power is isolated

More information

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Locking Type. Power Supply. Operating Radius, Min

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Locking Type. Power Supply. Operating Radius, Min TLS- General 1-2-Opto-electronics 3-Interlock Logic Description The TLS- is a positive mode, tongue operated guard locking interlock switch that locks a machine guard closed until power is isolated and

More information

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs. Safety Contacts

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Outputs. Safety Contacts Interlock Hinge Sprite General 1-2-Opto-electronics 3-Interlock Logic Power The Sprite is a hinge-actuated safety interlock switch in a compact housing only 75 x 25 x 29 mm (2.95 x 0.98 x 1.14 in.) making

More information

Non-contact Machine Safeguarding with RFID Technology. LED offers diagnostics for switch status, margin alignment, and fault finding

Non-contact Machine Safeguarding with RFID Technology. LED offers diagnostics for switch status, margin alignment, and fault finding Interlock SensaGuard Non-Contact 440N RFID unique (high) or standard (low) coded actuators PLe Cat 4 per ISO 3849- (safety performance is maintained when connected in series) Flat pack and barrel (plastic

More information

Specifications. Functional Safety Data Note: For up-to-date information, visit Certifications.

Specifications. Functional Safety Data Note: For up-to-date information, visit  Certifications. Safety Non-Contact General 1-2-Opto-electronics 3-Interlock Logic Description When it comes to machine safety, Rockwell Automation knows that protection of personnel and equipment is your main concern.

More information

SensaGuard. Description. Features. Benefits. Specifications

SensaGuard. Description. Features. Benefits. Specifications SensaGuard Description When it comes to machine safety, Rockwell Automation knows that protection of personnel and equipment is your main concern. At the same time, flexibility and productivity are points

More information

Safety Products Core Products Document

Safety Products Core Products Document Safety Products Core Products Document Interlock Switches Position (Limit) Switches Safety Relays Emergency Stop Devices Presence Sensing Safety Devices Trapped Key Interlock Switches Contactors & Control

More information

Bulletin 440, 442, 802 Safety Product Overview

Bulletin 440, 442, 802 Safety Product Overview EC 1.qxd 7/7/2006 3:50 PM Page 5-9 Bulletin 440, 442, 802 Product Overview Type Bulletin 440L 442L 440F 440K s Compliance Certifications Features Product Selection Presence Sensing Devices Light Curtains

More information

4-20 Visit our website: Emergency Stop. Devices. Stop Devices. 4-Emergency. Operator Interface Enabling Switches Overview

4-20 Visit our website: Emergency Stop. Devices. Stop Devices. 4-Emergency. Operator Interface Enabling Switches Overview Overview 2 Stop Overview An enabling device is a manually operated control device used in conjunction with a start control. The safety function of the enabling switch has two parts: 1) when continuously

More information

Bulletin 440R 440R 440R-S

Bulletin 440R 440R 440R-S 6 / 2011 Relays and Controllers (440R, 1752) Bulletin 440R, 1752 Relays & Controllers Product Line Overview Bulletin 440R 440R 440R-S Type Features Approvals Standards Product Selection MSR100 Dedicated

More information

Versatile Safety Interlock Switch with Guard Door Locking

Versatile Safety Interlock Switch with Guard Door Locking R Conforms to EN1088, EN60947-5-1, EN292, EN60204-1 UL and C-UL listed, BG approved Versatile Safety Interlock Switch with Guard Door Locking High locking force of 450 pounds locks guard door shut until

More information

Using the Safety Distribution R Box

Using the Safety Distribution R Box Safety Application Example Using the Safety Distribution R Box Introduction...2 Important User Information...2 General Safety Information...3 Description...4 SensaGuard Connections...8 Tongue Interlock

More information

Universal Tongue-Operated Safety Interlock Switch

Universal Tongue-Operated Safety Interlock Switch Rev. 12.07 C R US Conforms to EN1088, EN292, EN60947-5-1, EN60204-1 UL and C-UL listed, B approved T12 Universal Tongue-Operated Safety Interlock Switch Strong and versatile the compact size of the strong,

More information

Safety Light Curtains GuardShield Remote Teach

Safety Light Curtains GuardShield Remote Teach Specifications Presence Sensing Safety Devices Description The system provides a remote means of changing a fixed blanking configuration within the GuardShield safety light curtain. This keyswitch box

More information

Safety Interlock Switches

Safety Interlock Switches r Safety Interlock Switches Compact Universal Tongue- Operated Safety Interlock Switch Strong and versatile the compact size of the strong, glass-filled polyester housing can be used in many applications

More information

Using TLS3-GD2 Guardlocking Interlock with ArmorBlock Guard I/O and SmartGuard Controller

Using TLS3-GD2 Guardlocking Interlock with ArmorBlock Guard I/O and SmartGuard Controller Safety Application Example Using TLS3-GD2 Guardlocking Interlock with ArmorBlock Guard I/O and SmartGuard Controller Guardlocking with On-machine Components Safety Rating: Category 3, according to EN954-1

More information

SafeC S to MSR127 Conversion

SafeC S to MSR127 Conversion Application Note SafeC S to MSR127 Conversion IMPORTANT: A risk assessment must be completed to assure that all tasks and hazards are considered and confirm that the example circuit will provide adequate

More information

Bulletin 871L & 872L Limit Switch Style

Bulletin 871L & 872L Limit Switch Style Bulletin 871L & 872L Description Bulletin 871L and 872L inductive proximity sensors are selfcontained, general purpose, solid state devices designed to sense the presence of metal objects (ferrous and

More information

Versatile Safety Interlock Switch with Guard Door Locking

Versatile Safety Interlock Switch with Guard Door Locking Rev..11 C R US Confms to EN1088, EN60947-5-1, EN292, EN60204-1 UL and C-UL listed TL8012-S Versatile Safety Interlock Switch with uard Do Locking High locking fce of 2000 N (450 lb.) locks guard do shut

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. R Safety Interlock Switches TL8012-S TL8012 For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Versatile Safety Interlock

More information

24 VDC or 24 VAC/DC or 110 VAC or 220 VAC NOTE: 220 VAC not available for S2 and S3 configurations. EN1088, EN , EN292, EN

24 VDC or 24 VAC/DC or 110 VAC or 220 VAC NOTE: 220 VAC not available for S2 and S3 configurations. EN1088, EN , EN292, EN Safety Interlock Switches TL8012-S Versatile Safety Interlock Switch with Guard Door Locking High locking force of 2000 N (450 lb.) locks guard door shut until machine is safe to enter NEMA 6 enclosure

More information

3-56. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Non-Contact Switches SensaGuard

3-56. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Non-Contact Switches SensaGuard Safety General 1-2-Opto-electronics 3-Interlock Logic Description When it comes to machine safety, ockwell Automation knows that protection of personnel and equipment is your main concern. At the same

More information

NHP SAFETY REFERENCE GUIDE

NHP SAFETY REFERENCE GUIDE NHP SAFETY REFERENCE GUIDE GSR SAFETY FUNCTION DOCUMENTS 2 Hand Control Safety Function 800Z Zero Force Buttons / MSR125 Safety Relay / GSR SI Safety Relay Table of Contents: Introduction 6-3 Important

More information

SensaGuard 18 mm Barrels

SensaGuard 18 mm Barrels Installation Instructions Original Instructions SensaGuard 18 mm Barrels Catalog Numbers Low-Level Coding: 440N-Z1S16A, 440N-Z1S16B, 440N-Z1S16H, 440N-Z1S16J, 440N-Z1S17A, 440N-Z1S17B, 440N-Z1S17H, 440N-Z1S6A,

More information

AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY. INSTALLATION INSTRUCTIONS Document Number:

AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY. INSTALLATION INSTRUCTIONS Document Number: Minarik Variable Speed AC Motor Drives AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY INSTALLATION INSTRUCTIONS Document Number: 250-0297 These instructions apply to models rated: 7.5 25

More information

Presence Sensing Safety Devices

Presence Sensing Safety Devices Presence Sensing Devices GuardShield POC Type 4 440L Point of Operation Control (POC) for finger or hand protection Heavy-duty IP65 housing Large operating range 0.3 6 m (0.98 52.49 ft) Dip switch selectable

More information

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Inputs. Switching Voltage, Min. Conductor Size, Max.

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Inputs. Switching Voltage, Min. Conductor Size, Max. Specialty Safety elays CU3 Back EF onitors General Principles 9-10-Safety 5-Safety elays The CU3 is a control unit which detects stopped motion and is ideal for use with guard locking interlock switches.

More information

Ag Leader Technology Insight. Direct Command Installation Spra-Coupe 7000 Series

Ag Leader Technology Insight. Direct Command Installation Spra-Coupe 7000 Series Note: Indented items indicate parts included in an assembly listed above. Part Name / Description Part Number Quantity Direct Command Spra-Coupe 7000 Kit 4100531 1 Liquid Product Control Module 4000394

More information

Safety Systems Safety Integrated

Safety Systems Safety Integrated 3SE2 / SE3 Molded plastic /metal enclosure with separate actuator Application Safety interlock switches with separate actuator are used where the position of doors, covers or safety screens must be monitored

More information

Safety Systems Safety Integrated

Safety Systems Safety Integrated 3SF3 Limit, interlock and cable-operated Overview It is possible to directly connect selected limited, interlock and cable-operated switches via AS-Interface with safety-oriented communication. In these

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock

More information

Specifications. Description. Degree of Protection. Input Voltage (Relay type) Input Voltage (Solid-State type) Electrical Design Life (Relay type)

Specifications. Description. Degree of Protection. Input Voltage (Relay type) Input Voltage (Solid-State type) Electrical Design Life (Relay type) General Principles 9-10-Safety Logic Power General Purpose 800Z-GF2Q5 Heavy Industrial 800Z-HF1 General Purpose 800Z-GL3Q5B Heavy Industrial 800Z-HL1Y Bulletin 800Z Zero-Force are designed for use by machine

More information

SAFETY LOCKING DEVICES

SAFETY LOCKING DEVICES L200 Heavy-Duty L200 Safety Locking Device on a very large gate in a logistics operation with forklift traffic The L200 Safety Locking Device designed for highly demanding applications is predestined for

More information

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches R Safety Interlock Switches CM Series CM For full product information, visit www.sti.com. Use the SpeedSPEC Code for quick access to the specific web page. Most Diverse and Flexible Line of Coded Magnetic

More information

Product Discontinuation Notices. Discontinuation Notice of Safety Laser Scanner Type OS3101 series

Product Discontinuation Notices. Discontinuation Notice of Safety Laser Scanner Type OS3101 series PRODUCT NEWS Product Discontinuation Notices July 4, 2011 Presence Detection Sensors No. 2011195E Discontinuation Notice of Safety Laser Scanner Product Discontinuation Safety laser scanner Accessories

More information

NHP SAFETY REFERENCE GUIDE

NHP SAFETY REFERENCE GUIDE NHP SAFETY REFERENCE GUIDE GSR SAFETY FUNCTION DOCUMENTS E-Stop Safety Function Table of Contents: Introduction 6-18 Important User Information 6-18 General Safety Information 6-19 Safety Function Realization

More information

IEC Contactors. Auxiliary Contact Blocks GENERAL

IEC Contactors. Auxiliary Contact Blocks GENERAL IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount

More information

Application Technique. Safety Function: Safe Limited Speed and Safe Maximum Speed

Application Technique. Safety Function: Safe Limited Speed and Safe Maximum Speed Application Technique Safety Function: Safe Limited Speed and Safe Maximum Speed Products: TLSZR-GD2 Guard Locking Switch/Guardmaster Safety Relay/ PowerFlex 70 Drive Safety Rating: PLd, Cat. 3 to EN ISO

More information

NHP SAFETY REFERENCE GUIDE

NHP SAFETY REFERENCE GUIDE NHP SAFETY REFERENCE GUIDE PRODUCTS Safety Light Curtains and Laser Scanners Guardshield Series Standard Features: Fixed blanking - teachable Floating blanking One beam floating blanking on 30 mm resolution

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies RT contactors, size S00 The product range at a glance The new generation is a complete, modular system family, logically designed right down to the last detail, from the basic units to the accessories.

More information

Safety Monitoring Relays

Safety Monitoring Relays Safety Monitoring Relays Contents Selection Guide I-2 Safety Monitoring Relays G9SA I-6 SR101A I-12 SR103AM I-13 SR104P I-17 SR105E I-17 SR106ED I-21 SR108AD & SR109AD I-18 SR120MP I-21 SR125SMS45 I-22

More information

Presentation. EUCHNER Multifunctional Gate Box MGB

Presentation. EUCHNER Multifunctional Gate Box MGB Presentation EUCHNER Multifunctional Gate Box MGB Page 1 EUCHNER Multifunctional Gate Box MGB Guard locking / Interlocking Device Interlocking device MGB-L 0. Locking device MGB-L 1 Mechanical locking/

More information

Bulletin 871D Cylinder Position Inductive Style

Bulletin 871D Cylinder Position Inductive Style Bulletin 871D Cylinder Position Inductive Style Description Bulletin 871D cylinder position inductive proximity sensors are self-contained solid state devices. These devices are designed for sensing metal

More information

Raven Adapter Harness

Raven Adapter Harness Note: Indented items indicate parts included in an assembly listed above Quantity by System Part Name/Description Part Number With Switch Box With Built-in Switches Raven Harness Adapter Kit 4100504 1

More information

Compact Coded Magnetic Safety Interlock Switch and Control Units

Compact Coded Magnetic Safety Interlock Switch and Control Units C Conforms to EN292, EN60204-1, EN954-1, EN1088, EN60947-5-3, EN947-5-3, EN50081, EN50082, EN61000-6-2 UL and C-UL listed, TUV certified Description R US Compact Coded Magnetic Safety Interlock Switch

More information

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual Your Global Flow Control Partner Series 50 Valve Status Monitor Table of Contents 1. Definition of Terms... 2 2. Safety... 2 3. Storage... 3 4. Commissioning... 3 4.1. Mounting your VSM... 3 4.2. Wiring

More information

sirius Switching. Protecting. Starting. SIRIUS Product Overview

sirius Switching. Protecting. Starting. SIRIUS Product Overview sirius Switching. Protecting. Starting. SIRIUS Product Overview S00 Design Direct-on-line starting Reversing duty Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D Consisting of: wiring kit busbar

More information

Muting Applications with the MSR300 Table of Contents

Muting Applications with the MSR300 Table of Contents Application Note Muting Applications with the MSR00 Table of Contents ) Purpose... ) References... ) Muting Input Module... ) Muting Sensors... 5) Muting Lamp Module... 6) Reset... 7) Saving the Configuration

More information

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication Remote I/O Scanner Catalog Number 1747-SN Installation Instructions 2 Remote I/O Scanner Important User Information Because of the variety of uses for the products described in this publication, those

More information

Electrical Demand Specification (Reference SOP: )

Electrical Demand Specification (Reference SOP: ) Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3

More information

H3CA-8H-AC/100/110/120

H3CA-8H-AC/100/110/120 Solid-State Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay, Repeat

More information

MSR42 Micro 400 Controller/Muting Module

MSR42 Micro 400 Controller/Muting Module MSR42 Micro 400 Controller/Muting Module Description The MSR42 multi-function safety relay is the control module for the GuardShield Micro 400 safety light curtain, but can also be used with any light

More information

Bulletin 280/281 ArmorStart Distributed Motor Controller Overview

Bulletin 280/281 ArmorStart Distributed Motor Controller Overview Overview 1 2 3 5 6 7 8 9 10 11 12 13 The Bulletin 280/281 ArmorStart Distributed Motor Controller is an integrated, pre-engineered, starter for full-voltage and reversing applications. The ArmorStart offers

More information

Lifeline 5 Cable-pull Safety Switch

Lifeline 5 Cable-pull Safety Switch Installation Instructions Original Instructions Cable-pull Safety Switch Catalog Numbers 440E-LL5SS8, 440E-LL5SS5, 440E-LL5SE8, 440E-LL5SE5, 440E-LL5SN8, 440E-LL5SN5 Topic Additional Resources 1 Introduction

More information

Safety switches with separate actuator

Safety switches with separate actuator 4 Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD VF KEYD6 VF KEYD VF KEYD10 ACTUATORS CONTACT BLOCKS 6 snap action overlapped FR FX FK FW 0 1 4 NC NO+1NC

More information

Control Box Setup - PRSalpha

Control Box Setup - PRSalpha 888-680-4466 ShopBotTools.com Control Box Setup - PRSalpha Copyright 2016 ShopBot Tools, Inc. page 1 Copyright 2016 ShopBot Tools, Inc. page 2 Parts List: Hooking Up a PRSalpha Gantry Tool Powering the

More information

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A pool/spa control system IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller User s and Installation Guide P/N 520886 - Rev A *520886* i MobileTouch Wireless Controller kit contents The

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

SIGUARD Safety Systems Safety Integrated

SIGUARD Safety Systems Safety Integrated SE 10 / SE. 00 / SE. 4 / SE. 5 Molded plastic / metal enclosure with separate actuator Application Safety interlock switches (limit switches) with separate actuator are used where the position of doors,

More information

Remote access to status, test and reset functions. Built-in diagnostic indicators. Options Lid-mounted reset key switch (MC4)

Remote access to status, test and reset functions. Built-in diagnostic indicators. Options Lid-mounted reset key switch (MC4) File no. LR90200 Description mats and edges MC3, MC4 and Safety Mat Controllers Both metal enclosure and DINrail mount models available Control reliable Remote access to status, test and reset functions

More information

Specifications N Termination Voltage Range Current Consumption, Max. Type Number Termination. Voltage Range. Sinking Sensor Current

Specifications N Termination Voltage Range Current Consumption, Max. Type Number Termination. Voltage Range. Sinking Sensor Current Description The N24 Controller is a specialized Motorized Roller Driver Module for NorthAmCon Mech-Rollers. It includes the following features: 6 PNP Auxiliary I/O points to provide enhanced diagnostic

More information

Next Generation Guardmaster Safety Relay (GSR)

Next Generation Guardmaster Safety Relay (GSR) Wiring Diagram Next Generation Guardmaster Safety Relay (GSR) Bulletin 0R Quick Reference Page Safety Relay Modules Input Devices Output Devices SIL CL Category Number 6 SI E-stop PowerFlex d 0 SI MAB

More information

ArmorConnect Power and Control Media

ArmorConnect Power and Control Media Selection Guide ArmorConnect Power and Control Media Bulletins 280, 888, 889, 898 2 Bulletin 280, 888, 889, 898 Power Media Product Overview Media Description Features Trunk Cable Cordset - Cable with

More information

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. R Safety Monitoring Relays For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Dual-Channel Safety Monitoring Relay Power

More information

NHP SAFETY REFERENCE GUIDE

NHP SAFETY REFERENCE GUIDE NHP SAFETY REFERENCE GUIDE GSR SAFETY FUNCTION DOCUMENTS Safe Limited Speed and Safe Maximum Speed Table of Contents: General Safety Information 6-83 Introduction 6-85 Safety Function Realization: Risk

More information

SMARTSCAN INFORMATION

SMARTSCAN INFORMATION SMARTSCAN INFORMATION RY4 SERIES SAFETY RELAYS HANDBOOK Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954, Email: sales@smartscan.com, www.smartscan.co.uk

More information

INSTALLATION MANUAL. LO SIDE BOX ADD-ON KIT For driver or passenger side configurations TRUCK STORAGE SOLUTIONS FOR THE WAY YOU WORK

INSTALLATION MANUAL. LO SIDE BOX ADD-ON KIT For driver or passenger side configurations TRUCK STORAGE SOLUTIONS FOR THE WAY YOU WORK TRUCK STORAGE SOLUTIONS FOR THE WAY YOU WORK INSTALLATION MANUAL LO SIDE BOX ADD-ON KIT For driver or passenger side configurations Model: QDKSBDO1 -or- QDKSBP01 Part No. 24-0327 Rev. A ECN 5430 ATTENTION:

More information

Connecting a Cisco Output Module

Connecting a Cisco Output Module CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which

More information

SRI-02 Speech Recognition Interface

SRI-02 Speech Recognition Interface SRI-02 Speech Recognition Interface Data & Construction Booklet The Speech Recognition Interface SRI-02 allows one to use the SR-07 Speech Recognition Circuit to create speech controlled electrical devices.

More information

3RT, 3TB, 3TF Contactors for Switching Motors

3RT, 3TB, 3TF Contactors for Switching Motors RT, TB, TF Contactors for Switching Motors Overview RT contactors and coupling relays Size S00 with mountable accessories The SIRIUS generation of controls is a complete, modular system family, logically

More information

Magnetically Actuated Safety Interlock Switches

Magnetically Actuated Safety Interlock Switches Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,

More information

Digital ac/dc (24V) Input Module

Digital ac/dc (24V) Input Module Installation Instructions Digital ac/dc (24V) Input Module Catalog Number 1771-IND, Series C Topic Page Important User Information 2 Before You Begin 3 Power Requirements 3 Prevent Electrostatic Discharge

More information

A Axis M-Functions Level 1 A Axis Standard A Axis SMT Level 2. Each console includes the following:

A Axis M-Functions Level 1 A Axis Standard A Axis SMT Level 2. Each console includes the following: Hardware List The 3000M Crusader II Upgrade system has been custom configured to provide the necessary hardware required for installation on your machine. Verify that you have received all the correct

More information

Safety switches with separate actuator

Safety switches with separate actuator A Safety switches with separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS CONTACT BLOCKS 9 snap action overlapped FD FP FL FC 21 22 33 3 3NC 2NO+1NC 1NO+ CONDUIT

More information

Copyright 2011 Rockwell Automation, Inc. All rights reserved. Next Generation Guardmaster Safety Relay Platform Overview

Copyright 2011 Rockwell Automation, Inc. All rights reserved. Next Generation Guardmaster Safety Relay Platform Overview Next Generation Guardmaster Safety Relay Platform Overview RA Safety Relays MSR Minotaur Safety Relay MSR6 Rockwell Automation s first electromechanical safety relay series MSR100 2nd generation of electromechanical

More information

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5

More information

AC Micro Style Cordsets and Receptacles

AC Micro Style Cordsets and Receptacles AC Micro Style Cordsets and Receptacles Description Rockwell Automation/Allen-Bradley offers a wide variety of connection products for interfacing field devices to I/O, junction boxes, PLCs, etc. Connection

More information

System family AR. Transponder-coded safety switch CET.-AR- With guard locking

System family AR. Transponder-coded safety switch CET.-AR- With guard locking System family R Transponder-coded safety switch CET.-R- With guard locking 1...20 Cat. 4 PLe Safety switch with guard locking Locking force up to 600 N etal housing Diagnostics via 4 LEDs Notice The device

More information

ArmorBlock MaXum I/O and ArmorBlock I/O Selection Guide. 1792D and 1732 Series

ArmorBlock MaXum I/O and ArmorBlock I/O Selection Guide. 1792D and 1732 Series ArmorBlock MaXum I/O and ArmorBlock I/O Selection Guide 1792D and 1732 Series 2 ArmorBlock I/O Overview The ArmorBlock family provides industrially hardened blocks of 24V dc digital I/O that can be mounted

More information

DeviceNet Physical Media

DeviceNet Physical Media DeviceNet Physical Media Round Media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths. A wide variety of rugged, durable DeviceNet components is

More information

Series Panel Mounted Control Devices

Series Panel Mounted Control Devices E_Master2012.qxd:NEW_E_Master_temp.qxd 1/27/12 4:28 PM Page 1 Series Features: Suitable for hazardous and corrosive locations. Installation is easy and precise. Devices fit into a standard 30.5mm, 1.2"

More information

Transponder-coded. with guard locking

Transponder-coded. with guard locking Transponder-coded safety switch CTP with guard locking The safety switch CTP The new safety switch CTP combines the proven principle of operation of electromechanical safety switches with guard locking

More information

Replacement Keyswitch Assembly

Replacement Keyswitch Assembly Installation Instructions Replacement Keyswitch Assembly (Catalog No. 2711E-NKSW1) Applicable Terminals Use this replacement keyswitch with PanelView Terminals 2711-KA1, -KC1, -TA1, -TC1, -TA4, -TC4 and

More information

Manual and Protocol Description

Manual and Protocol Description Communication Module MSR240 1 Manual and Protocol Description Overview The MSR240 Communication Module serves as an interface between a MSR210 or MSR211 Basic Module and a standard serial data communication

More information

Uninterruptible Power Supplies

Uninterruptible Power Supplies Xi Series 1-6kVA True On-Line UPS Features Rack-Mount/Standalone Format Universal Battery Design (Optional 10 year batteries) Dual Mains Input Dual Position Backlit LCD LCD Load Segment Control 2.5kVA

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G

More information

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches HSA-DMC Magnetic Safety Switches Key features: Compact size and easy positioning. Combination with proprietary relay modules achieves safety category 4 (EN954-1). Compact size ( 16 51mm) Positioning for

More information

SMARTSCAN INFORMATION T4 SERIES LIGHT CURTAINS HANDBOOK

SMARTSCAN INFORMATION T4 SERIES LIGHT CURTAINS HANDBOOK SMARTSCAN INFORMATION T4 SERIES LIGHT CURTAINS HANDBOOK Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954, Email: sales@smartscan.com, www.smartscan.com

More information

Using GuardShield Light Curtains (Safe 4, Micro 400, or 440L), with ArmorBlock Guard I/O and SmartGuard Controller

Using GuardShield Light Curtains (Safe 4, Micro 400, or 440L), with ArmorBlock Guard I/O and SmartGuard Controller Safety Application Example Using GuardShield Light Curtains (Safe 4, Micro 400, or 440L), with ArmorBlock Guard I/O and SmartGuard Controller Light Curtain with On-machine Components Safety Rating: Category

More information

S Reclosers Kyle Type VXE Electronic Control SCADA Input/Output Board Installation and Operation Instructions

S Reclosers Kyle Type VXE Electronic Control SCADA Input/Output Board Installation and Operation Instructions Reclosers Kyle Type VXE Electronic Control SCADA Input/Output Board Installation and Operation Instructions Cooper Power Systems Service Information S0-6- Applicable to VXE5 reclosers serial number 006

More information

Bulletin 854K 60 Mm Control Tower Stack Lights

Bulletin 854K 60 Mm Control Tower Stack Lights Bulletin 854K 60 Mm Control Tower Stack Lights UL Type 4/4X/13, IP66 "No tools" lens assembly Surface, vertical, M20 threaded tube, quick release base, 1/2 in. NPT, double-sided base, M12 (5-pin DC) micro

More information