Test equipment, adapters and facilities

Size: px
Start display at page:

Download "Test equipment, adapters and facilities"

Transcription

1 corpuls³ Safety Technical Test, Test instruction and test report 1/16 Safety Technical Test For legal requirements and periods of Safety Technical Tests see chapter of Operators Instruction. Implementation of Safety Technical Tests is only accepted when carried out according to both, this test instruction and the Operators Instruction, and at least documented according to this test report. Warning Implementation of Safety Technical Tests implies the occurrence of high voltages which may result in severe injuries or death. Only authorized qualified personnel are permitted to carry out Safety Technical Tests. Attention Safety Technical Tests should only be carried out by authorized personnel with calibrated measuring equipment and simulators. Test equipment, adapters and facilities Description Safety analyzer to perform protective earthing-, device leakage current-, isolation resistance measurement and high voltage test Defibrillator/Pacer analyzer Multi parameter/ecg simulator Digital multimeter Digital fine manometer Mains charger with magnetic plug, 12 volts DC / 9 amp. Test cable set for Safety Technical Test Patient Box corpuls³ Test cable set for Safety Technical Test Defibrillator Unit corpuls³ Test cable for Safety Technical Test Display Unit corpuls³ with LAN Paddle holder for leakage current and H/V testing, corpuls³ Paddle for leakage current and high voltage testing corpuls³ (2 pcs. required) Test cable Safety Technical Test Charger with magnetic plug corpuls³ Manufacturer or supplier Model EKU Elektronik GmbH, D Leiningen MTP 6000 (or comparable) Fluke Biomedical Division, Everett, WA 98203, U.S. Impulse 7000 (or comparable) Fluke Biomedical Division PS420 (or comparable) Fluke Corporation Series 80V (or comparable) GREISINGER electronic GmbH, D Regenstauf GMH (or comparable) GS Elektromedizinische Geräte G. Stemple GmbH, D Kaufering Part no W W W W W W

2 corpuls³ Safety Technical Test, Test instruction and test report 2/16 Adapter for leakage current test W Masimo Rainbow Module T-connector cable Test instruction for Safety Technical Test 1 Check of external mechanical intactness of the device 1.1 Check of mechanical intactness. The device must neither have form cracks nor fractures. In case of damage, present the device to an authorized national or local GS representative for repair. Swivel the complete device about 30. The mechanisms must neither be too rough-running nor automatically tilting. 1.2 Check covers and fasteners for completeness. 1.3 Check of shock paddles intactness. The paddles must be free from form cracks in their synthetic material; the helix cable, the electrode plates and the safety electrodes must be free of any damage; rubber caps of the buttons must be available and undamaged, labels must be available. The connector must easily and surely be lockable with the therapy cable. The electrode surfaces should be free of gel leftovers and other contamination. 1.4 Check of attached cables and sensors. Check cleading of cables and sensors for insulating damage; if necessary remove paste-on labels installed by the operator. Continued use of broken cables and sensors is forbidden. 1.5 Check printer assembly, lid and locking mechanism. The printer lid should easily release and lock. 1.6 Check of labels, warning and safety instruction plates for completeness and readability. Check of type plates for readability. Note the serial numbers of each single component to be tested in the test report sheet. 1.7 Check interlocking mechanisms between the single components. Therefore unlock and relock the components. The interlocking mechanism must be free of damage. 1.8 Check the magnetic connector contact panels of the of the single components for damage and pollution. Clean the panels if necessary. 1.9 Shaking test. Shake each of the single components to detect loose parts inside. Warning Do not open the device! Inner parts may be under high voltage. Disregarding may cause severe injuries or death! In case of defect contact your authorized national or local GS representative for inspection and potential repair.

3 corpuls³ Safety Technical Test, Test instruction and test report 3/16 2 Protection against electrical shock hazard Attention Attention During following measurements, all single components must be separated from electrical power supply (power supply pack). Take the batteries out of the single components! Performance of both the leakage current measuring of application parts (item 2.6) and the high voltage test (item 2.7) requires the application of the specified GSspecific adapters and facilities. Using other adapters and facilities may result in device damage and termination of warranty rights! 2.1 Check of protective earthing of the external power supply pack (IEC 62353:2007, item , image 1, protection class I). Connect the mains plug to the safety tester and measure with the probe at the minus pole of the corpuls magnet connector using the test cable P/N W to activate the switch inside the male connector. Testing current must be not less than 200 ma and must not exceed a limit of 10 A. This step must not be done for power supplies with part number and Measuring of device leakage current of external power supply pack (IEC 62353:2007, item , image 4, protection class I) (direct measurement). 2.3 Measuring of insulation resistance of the external power supply pack (IEC 62353:2007, item 5.3.4, image 9). Testing voltage 500 V (DC). 2.4 Measuring of line resistance between potential equalization plug and minus pins of power contact field of the Defibrillator Unit (by using a Hirschmann clip or an alligator clip). Remove cover if required. Testing current must be not less than 200 ma and must not exceed a limit of 10 A. The potential equalization plug may be covert by a plastic cover. 2.5 Measuring of line resistance between safety electrodes of connected shock paddles and potential equalization plug by using a resistance measuring gauge. Testing current must not exceed a limit of 1 A. 2.6 Measuring of leakage current of application parts (IEC 62353:2007, item , image 6, protection class I). Application parts at which is not currently measured, must be grounded (to the potential equalization plug of the Defibrillator Unit or to minus contact of the corpuls magnet connector of the Patient Box). Measure between: High voltage output of therapy cable/therapy socket with connected shock paddles and potential equalization plug (connect the shock paddles to the therapy cable/therapy socket and put on the adapter P/N w ) High voltage output of therapy cable/therapy socket with connected T-connector cable (P/N ) and potential equalization plug. The measuring is only required if internal shock electrodes (shock spoons) are applied High voltage output of test signal connector and potential equalization plug.

4 corpuls³ Safety Technical Test, Test instruction and test report 4/ Short-wired test contact pins of the paddle trays and potential equalization plug (if the test contact pins were replaced by accessory bags Part no and , the original condition must be restored for the time of measurement) ECG inputs (4-pole and 6-pole connected) and minus contact of the corpuls magnet connector of SpO 2 input and minus contact of the corpuls magnet connector of CO 2 input and minus contact of the corpuls magnet connector of the Patient Box Input Temp1 and minus contact of the corpuls magnet connector of Input Temp2 and minus contact of the corpuls magnet connector of Input IBP1 and minus contact of the corpuls magnet connector of Input IBP2 and minus contact of the corpuls magnet connector of CPR input and minus contact of the corpuls magnet connector of LAN connector and minus contact of the corpuls magnet connector of the Display Unit. 2.7 High voltage test of application parts (IEC :2002, item 20, image 107). Application parts at which is not currently measured, must be grounded (to the potential equalization plug of the Defibrillator Unit or to minus contact of the corpuls magnet connector of the Patient Box). Set the current limiter of the high voltage generator to 500 µa. No high voltage flashover must appear; no release of the current limiter. Apply 5 kv (DC) for 30 sec each between: High voltage output of therapy cable/therapy socket with connected shock paddles and potential equalization plug (connect the shock paddles to the therapy cable and put on the adapter P/N w ) High voltage output of test signal connector and potential equalization plug Short-wired test contact pins of the paddle trays and potential equalization plug (if the test contact pins were replaced by accessory bags Part no and , the original condition must be restored for the time of measurement) ECG inputs (4-pole and 6-pole connected) and minus contact of the corpuls magnet connector of SpO 2 input and minus contact of the corpuls magnet connector of CO 2 input and minus contact of the corpuls magnet connector of the Patient Box Input Temp1 and minus contact of the corpuls magnet connector of Input Temp2 and minus contact of the corpuls magnet connector of

5 corpuls³ Safety Technical Test, Test instruction and test report 5/ Input IBP1 and minus contact of the corpuls magnet connector of Input IBP2 and minus contact of the corpuls magnet connector of CPR input and minus contact of the corpuls magnet connector of LAN connector and minus contact of the corpuls magnet connector of the Display Unit. 3 General functions (charging, network connection) For all following checks reinstall the batteries to the single components. The single components will automatically switch on. Shutdown the single components by operating the PWR on/off buttons and reassemble them to a compact device. 3.1 Switch on the compact device by operating the PWR button of the Display Unit. Wait for boot-up (approx. 20 sec) then check network status. 3.2 Separate Defibrillator Unit, and then separate Patient Box from Display Unit (modular mode). Check network status. 3.3 Check network status on the LCD of Patient Box. 3.4 Connect power supply pack to corpuls magnet connector of Defibrillator Unit. Check charging control lamp of Defibrillator Unit. 3.5 Connect power supply pack to corpuls magnet connector of Patient Box. Check charging control lamp of Patient Box. 3.6 Reassemble Patient Box with Display Unit (semi-modular mode). Check charging control lamp of Display Unit. 3.7 Connect power supply pack to corpuls magnet connector of the Display Unit. Check charging control lamp of Display Unit. 3.8 Reassemble all single components to a compact device; connect power supply pack to corpuls magnet connector of Defibrillator Unit. Check charging control lamp of Display Unit. 4 Device function Display Unit For following tests operate the device in modular mode. 4.1 Check acoustics and keyboard of the Display Unit. Push every button of the keyboard. The speaker must answer with a tone. 4.2 Check printer functionality. Select menu item Test page. 4.3 Check alarm and printer stop in case of lack of paper. Remove paper reel and start printer operation. 4.4 Check visual alarm indication. In case of an alarm, the alarm lamp in the jogdial must light up. 4.5 Check GSM function. Install SIM and establish a connection to a fax recipient. Transmit a diagnosis ECG to the fax recipient. 4.6 Check the Health Insurance Card Reader. Insert an applicable card into the card reader slot; patient s data must appear on the screen. 4.7 Check the LAN function. Compare the MAC address of the device with the papers of the device. Connect the device to a DHCP server. Dial the assigned IP address of the device using the ping networking utility.

6 corpuls³ Safety Technical Test, Test instruction and test report 6/16 5 Device function Patient Box For following tests operate the device in modular mode. 5.1 ECG Monitoring Connect the 4-pole ECG cable to an ECG simulator and to the Patient Box. Select a sinus waveform and call-up the function Resting ECG at the Display Unit. The derivations I, II, III, avr, avl and avf must appear Connect a 6-pole ECG cable additionally to the ECG simulator and to The derivations V1 up to V6 must appear as well Check alarm function ECG electrode off. Disconnect each single wire from simulator and check the alarm. The alarm may fail to appear if the black wire is disconnected Operate the button at the Patient Box as often until the LCD of the Patient Box indicates the heart rate. 5.2 Pulse oximeter Depending on the Masimo Rainbow SET/Masimo SET module, connect the appropriate SpO2 /SpCO/SpHb/SpMet finger sensors to Apply the sensor to a proband. The parameters listed below must be indicated on the Display Unit (curves or vital parameter view boxes must be configured if necessary): - the arterial oxygen saturation SpO2 (>90 %), - the peripheral pulse rate PP, - the perfusion index PI, - the plethysmogram, - the carboxyhemoglobin concentration SpCO (< 10%), - the hemoglobin SpHb (10-17 g/dl), - the methemoglobin concentration SpMet (< 3%) Note: Reading of SpHb value takes about 2 ½ minutes Check alarm functions SpO2 sensor off and SpO2 cable off. First pull out the finger from the sensor, and then after release of the alarm, pull the cable out from 5.3 Capnometer Fix an airway adapter to the CO2 sensor, then connect the CO2 sensor to Breathe through the airway adapter. The parameters listed below must be indicated on the Display Unit (curves or vital parameter view boxes must be configured if necessary): - the CO2 partial pressure, - the respiratory rate, - the capnogram Check alarm function CO2 apnoea and CO2 cable off. First, discontinue breathing through the airway adapter, and then after release of the alarm, pull the cable out from 5.4 Temperature measurement

7 corpuls³ Safety Technical Test, Test instruction and test report 7/ Connect a temperature sensor to The ambient temperature must be indicated on the Display Unit (vital parameter view boxes must be configured if necessary). Retake the test with the 2 nd temperature input Check alarm Sensor T (x) off. Therefore, pull the temperature sensor out from the respective temperature socket. 5.5 Non-invasive blood pressure measurement Connect a cuff to the Patient Box and measure the blood pressure of a proband. The measuring cycle shall be passed completely and the values of systolic, diastolic and mean effective arterial pressure must be indicated on the Display Unit (one vital parameter view box must be configured if necessary). 5.6 Invasive blood pressure measurement Connect an invasive blood pressure simulator via an adapter cable to Set atmospherical pressure and calibrate channel P (x). Turn to an arterial pressure progression. The values of systolic, diastolic and mean effective arterial pressure (max. tolerance of ± 2 mmhg) as well as the pressure curve must be indicated on the Display Unit (curves or vital parameter view boxes must be configured if necessary). Retake the test with the three remaining pressure channels Check alarm function IBP sensor P (x) off. Therefore, pull the adapter cable out from the respective input or pull the sensor cable out from the intermediate adapter cable. 5.7 Audiovisual CPR Feedback Connect a CPR sensor to Move the CPR sensor up and down with a frequency of about 100 min -1. Vary the swivel altitude of sensor. The parameters as listed below must be indicated on the Display Unit (curves or vital parameter view boxes must be configured if necessary): - the compression rate (CPR rate), - course of curve of the actual thorax compression Check alarm function CPR sensor loose. Therefore, remove the sensor from the plugged CPR cable and, after release of the alarm, reconnect the sensor. Check alarm function CPR cable loose. Therefore, pull the CPR cable out from 5.8 Data recording Insert CompactFlash memory card to the slot of the Patient Box and start a new mission. Alternatively, the record can be started at the beginning of the functional test. Using the Operation Browser check the mission is recorded.

8 corpuls³ Safety Technical Test, Test instruction and test report 8/16 6 Device function Defibrillator/Pacer For the following tests, operate the device in modular mode. The battery of the Defibrillator Unit must be charged sufficiently for the following tests. If the device is operated w/o shock paddles, shock paddles must be provided for the following tests. 6.1 Function of defibrillator (IEC :2003, 50) Check ECG derivation of the Defibrillator/Pacer Unit. Therefore, connect the shock paddle electrodes/the therapy cable/the therapy socket to the defibrillator tester. Set up the analyzer to a sinus wave rhythm of 60 min -1 and check the indication at the Display Unit Check output of test signal at the contact pins of the shock paddle trays. Therefore, insert the shock paddles to the trays (if the test contact pins were replaced by accessory bags Part no and , the original condition must be restored for the time of test) Functional test of the discharging resistors of the shock paddle trays. Insert the shock paddles to the trays and release a shock with maximum energy (if the test contact pins are replaced by accessory bags Part no and , the original condition must be restored for the time of test) Check output of test signal at the test contacts of the cable base. Therefore plug the therapy cable into the test contact connector of the cable base Functional test of the discharging resistors of the cable base test contacts. Plug the therapy cable into the test contact connector of the cable base and release a shock with maximum energy Functional test of impedance measuring. Apply the shock paddles to the test pads of a Defibrillator/Pacer analyzer with an impedance of 50 Ω. If no shock paddles are used, perform this test using the T- connector cable P/N Test of energy output. Set advised energy level, charge, and release the shock immediately after reaching shock readiness asynchronously to the defibrillator tester. Release three shocks of each energy level and note the highest value Check of energy output of the baby shock electrodes. Place the baby shock electrodes at the adult shock paddles according to Operators Instruction. Release one shock with maximum energy level and note the value Check synchronous defibrillation. Supply a sinus rhythm of the simulator of the defibrillator tester and release a shock. Note the delay time. 6.2 Function of pacer Connect a terminating resistor of 700 Ω to the therapy cable using the T-connector cable P/N Call up the pacemaker function and set the parameters as advised below: - Mode FIX, - Intensity 30 ma, - Frequency 150 min -1. Measure the preset parameters and note the results Increase intensity to 150 ma and note the output current.

9 corpuls³ Safety Technical Test, Test instruction and test report 9/ Increase the terminating resistor to 1000 Ω and note the output current Short the electric circuit. The alarm Short circuit must appear on the Display Unit Disconnect the electric circuit. The alarm Circuit open must appear on the Display Unit. 7 Device function charging brackets 7.1 Check available charging brackets for mechanical intactness. Perform a visual inspection of connector plugs and cables of charging brackets with power supply. 7.2 Check operational capability of interlocking mechanisms of the brackets. Therefore insert the single components (Display Unit, Patient Box, Defibrillator Unit) to the brackets, then lock and unlock them. 7.3 Check power supply of the charging brackets (only charging brackets with available power connector). Insert the single components to the brackets, connect the brackets to the 12 volts power supply and check the charging lamps of the single components.

10 corpuls³ Safety Technical Test, Test instruction and test report 10/16 Metrological Controls For legal requirements and periods of Metrological Controls see chapter of Operators Instruction. Alternative legal regulation of other countries provided. Implementation of Metrological Controls is only accepted when carried out according to both this test instruction and the Operators Instruction, and at least documented according to this test report. Instruction of Metrological Control of function Non-invasive Blood Pressure Measurement (NIBP) 8 Leak tightness test of the pressure system and measuring accuracy test of indication For Metrological Control of the non-invasive blood pressure module the device under test must be connected to a calibrated pressure gauge, to a hand pump with nonreturn valve and release valve, further to a testing volume (inelastic metal tank of 1 liter volume) by using a four-way connector. Alternatively, a blood pressure simulator can be used. All tests require operation in calibration mode (Call up via menu items NIBP Test ). The calibration mode is automatically left after 3 minutes. 8.1 Generate a pressure of approx. 200 mmhg by using the hand pump. Run a pressure compensation sequence of approx. 30 seconds. Memorize the indicated value. After a delay of 60 seconds, read the indicated value; calculate and note the difference. 8.2 Successively generate the pressures 250 mmhg, 200 mmhg, 150 mmhg, 100 mmhg and 50 mmhg by using the hand pump. Wait a few seconds each for pressure compensation. Note values indicated on both, pressure gauge and device under test. Instruction of Metrological Control of function Temperature measuring 9 Measuring accuracy test of indication 9.1 Successively plug test jack connectors with calibrated resistors in temperature socket Temp1 and note the indicated value. Alternatively, a temperature simulator can be used. 9.2 Repeat this sequence for socket Temp2.

11 corpuls³ Safety Technical Test, Test instruction and test report 11/16 Test report of Safety Technical Test corpuls³ Nr of test report Operator Ambulance service/hospital Nr, street Single module Serial nr Inventory nr Software Display Unit Patient Box Defibrillator Unit Power supply City code City Accessories: Battery S/N 4-pole ECG cable CO2 sensor Battery S/N 6-pole ECG cable Temperature probe(s) Battery S/N SpO2 sensor Mounting Defibrillator Unit Shock paddles SpO2/SpCO/SpMet sensor Mounting Monitor Unit Baby shock electrodes SpO2/SpHb/SpMet sensor Mounting Patient Box Delete items where inapplicable! Pos Test description required result realized result passed failed 1 Check of external mechanical intactness of the device 1.1 Check of mechanical intactness, swivel mechanism no damages, 30 swiveling 1.2 Covers and fastening parts complete 1.3 Shock paddles undamaged 1.4 Cables and sensors undamaged 1.5 Printer (locking mechanism) fully functional 1.6 Labels, safety instruction plates, type plates complete, legibly 1.7 Locking mechanism between the single modules fully functional 1.8 Magnetic plug connector undamaged unpolluted 1.9 Shaking test no loose parts

12 corpuls³ Safety Technical Test, Test instruction and test report 12/16 Pos Test description required result realized result passed failed 2 Protection against electrical shock hazard 2.1 Check of protective earthing of pwr supply < 0.3 Ω Ω 2.2 Device leakage current of power supply < 500 µa S.F.C. µa 2.3 Isolation resistance of power supply > 70 MΩ MΩ 2.4 Protective conductor potential equalization Ground contact Defibrillator Unit < 0.1 Ω Ω 2.5 Resistance of safety electrodes < 0.6 Ω Ω 2.6 Leakage currents between device ground (potential equalization) and following application parts: Therapy cable with shock paddles (BF) < 500 µa S.F.C. µa Therapy cable/therapy socket (CF) < 100 µa S.F.C. µa Test signal output (BF) < 500 µa S.F.C. µa Test contact pins (BF) < 500 µa S.F.C. µa ECG inputs (4-pole + 6-pole) (CF) < 50 µa S.F.C. µa SpO2 input (BF) < 500 µa S.F.C. µa CO2 input (BF) < 500 µa S.F.C. µa Input Temp1 (BF) < 500 µa S.F.C. µa Input Temp2 (BF) < 500 µa S.F.C. µa Input IBP1 (CF) < 50 µa S.F.C. µa Input IBP2 (CF) < 50 µa S.F.C. µa CPR input (BF) < 500 µa S.F.C. µa LAN connector < 500 µa S.F.C. µa 2.7 High voltage test 5 kv (30 sec) between device ground (potential equalization) and: Therapy cable/therapy socket no flashover Test signal output no flashover Test contact pins no flashover ECG inputs (4-pole + 6-pole) no flashover SpO2 input no flashover CO2 input no flashover Input Temp1 no flashover Input Temp2 no flashover Input IBP1 no flashover Input IBP2 no flashover CPR input no flashover LAN female connector no flashover 3 General functions (Charging, network connection) 3.1 IrDA network connection as compact device Indication Display

13 corpuls³ Safety Technical Test, Test instruction and test report 13/16 Pos Test description required result realized result passed failed Radio network connection in modular mode Radio network connection in modular mode Indication Display Indication Patient Box 3.4 Power supply connected to Defibrillator Unit (modular mode) 3.5 Power supply connected to Patient Box 3.6 Power supply connected to Patient Box 3.7 Power supply connected to Display Unit 3.8 Power supply connected to Defibrillator Unit (compact device) 4 Device function Display Unit Charging indicator Defibrillator Unit on Charging indicator Patient Box on Charging indicator Display Unit on Charging indicator Display Unit on Charging indicator Display Unit on 4.1 Acoustics/keyboard Sound audible 4.2 Test printout 4.3 Paper deficiency function Total printing span readable Printer stops, alarm appears 4.4 Visual alarm indication Alarm lamp on 4.5 GSM function 4.6 Function of Health Insurance Card Reader Fax transmission successful Data appear on the screen 4.7 LAN function MAC address 5 Device function Patient Box 5.1 ECG Monitoring Resting ECG with 4-pole ECG cable Resting ECG with 4+6-pole ECG cables Alarm ECG Electrode off LAN connection is established Derivations I, II, III, avr, avl, avf Derivations V1 to V6 Practicable with each wire Indication Patient Box Heart rate 5.2 Pulse oximeter Indication Display Unit SpO2 value Pulse rate PI value Plethysmogram

14 corpuls³ Safety Technical Test, Test instruction and test report 14/16 Pos Test description required result realized result passed failed SpCO value SpHb value SpMet value Alarms SpO2 Sensor off SpO2 cable off 5.3 Capnometer Indication Display Unit Alarms 5.4 Temperature measuring Indication of room ambient temperature Alarm Sensor T (x) off CO2 partial pressure Respiratory rate Capnogram CO2 Apnoea CO2 cable off Indication T1 Indication T2 Sensor T1 off Sensor T2 off 5.5 Not invasive blood pressure measuring realistic results 5.6 Invasive blood pressure measuring Values and pressure curve Alarm IBP Sensor P (x) off 5.7 CPR Feedback Indication Display Unit Alarms Channel P1 Channel P2 Channel P3 Channel P4 Sensor P1 off Sensor P2 off Sensor P3 off Sensor P4 off CPR curve CPR rate CPR sensor loose CPR cable loose 5.8 Data recording on CompactFlash card Data available 6 Device function Defibrillator Unit 6.1 Function of defibrillator Heart rate min -1 min -1

15 corpuls³ Safety Technical Test, Test instruction and test report 15/16 Pos Test description required result realized result passed failed Test signal via shock paddles mounting Discharging resistors of shock paddles mounting Test signal via test contacts cable base Discharging resistors of test contacts cable base differentiated rectangular signal Shock released differentiated rectangular signal Shock released Impedance measuring Indication OOKO Energy output 20 J (16 24 J) J 100 J ( J) J 200 J ( J) J Energy output baby shock electrodes 20 J (18 22 J) J Delay synchronous defibrillation < 35 msec msec 6.2 Pacer function Rate min -1 min -1 Impulse width msec msec Output current ( Ω) ma ma Output current ( Ω) ma ma Output current ( Ω) ma ma Alarm Pacer short circuit Alarm appears Alarm Pacer circuit open Alarm appears 7 Device function charging mountings 7.1 Check of mechanical intactness undamaged 7.2 Interlocking mechanisms fully functional 7.3 Power conveyance Charging indicator on 8 Metrological Control of non-invasive blood pressure measuring module (valid to: ) 8.1 Tightness of pressure system Difference < 6 mmhg 8.2 Accuracy of indication mmhg (± 3 mmhg) mmhg (± 3 mmhg) mmhg (± 3 mmhg) mmhg (± 3 mmhg) - 50 mmhg (± 3 mmhg) Indication Display Indication pressure gauge

16 corpuls³ Safety Technical Test, Test instruction and test report 16/16 9 Metrological Control of temperature module (valid to: ) 9.1 Input Temp1-24 C or 30 C or C - 37 C - 40 C or 42 C or C ± 0.1 K Indication Display C C C 9.2 Input Temp2-24 C or 30 C or C - 37 C - 40 C or 42 C or C ± 0.1 K Indication Display C C C Result of Safety Technical Test Device is free of defects. Slight defects which should be occasionally fixed by an authorized service representative: - - Serious safety-related deficiencies which forbid any continued operation. The device must be repaired by an authorized service representative before restart of operation. - Appointed date for next Safety Technical Test: The Safety Technical Test has been carried out by (Name of the examiner): Date: Signature: Name and address of the responsible company (company stamp)

Argentine Manufacturer of Hospital Equipment. Electrocardiograph Pulse Oximeters Vital Signs Monitors

Argentine Manufacturer of Hospital Equipment. Electrocardiograph Pulse Oximeters Vital Signs Monitors Electrocardiograph Pulse Oximeters Vital Signs Monitors ELECTROCARDIOGRAPH Model: RG-401plus Model: RG-401 ELECTROCARDIOGRAPH Model: RG-401 Technical Specifications Accessories Carrying bag Patient cable

More information

the next generation life energy

the next generation life energy the next generation life energy the concept 3 The corpuls 3 offers an entirely new and revolutionary design-concept compared with traditional compact defibrillator/monitoring devices. It is designed as

More information

Cardiostart. Biphasic Defibrillator Monitor

Cardiostart. Biphasic Defibrillator Monitor Cardiostart Biphasic Defibrillator Monitor Standard Accessories Carrying Case Rechargeable lithium ion battery Set of accessories Other accessories upon request Internal Pads Adult / Pediatric / Neonatal

More information

Product Specifications

Product Specifications Product Specifications Physical Defibrillator Model HeartStart MRx (M3536A) Dimensions Without external paddles: 12.4 in. (W) x 7.7 in. (D) x 11.7 in. (H) (313 mm x 195 mm x 295 mm). With external paddles:

More information

ARGUS PRO LifeCare 2. Patient monitor, 12-channel ECG, defibrillator and pacemaker in a compact format F A C T U R M A N U A N D I N E D E U R O I G N

ARGUS PRO LifeCare 2. Patient monitor, 12-channel ECG, defibrillator and pacemaker in a compact format F A C T U R M A N U A N D I N E D E U R O I G N D I N A N D M A N U F A C T U R E D E D I G N S E E P E U R O Patient monitor, 12-channel ECG, defibrillator and pacemaker in a compact format Only 4.4 kg with Leading-edge technology is the key SCHILLER

More information

LIFEPAK CR PLUS/EXPRESS Defibrillator TABLE OF CONTENTS

LIFEPAK CR PLUS/EXPRESS Defibrillator TABLE OF CONTENTS Section Contents Performance Inspection Procedure The (PIP) is a set of manual and computerassisted test procedures used by authorized Physio-Control service representatives. It will be used as an operational

More information

INTRODUCTION The Monitor, interchangeable modules and storage batteries are described below. Refer to the table below for specifications.

INTRODUCTION The Monitor, interchangeable modules and storage batteries are described below. Refer to the table below for specifications. PRODUCT DESCRIPTION INTRODUCTION The Monitor, interchangeable modules and storage batteries are described below. Refer to the table below for specifications. DINAMAP MPS Select Portable Monitor General

More information

etco 2 SpO 2 IBP medlab 2017/2018 OEM Modules for Patient Monitoring medizinische Diagnosegeräte GmbH

etco 2 SpO 2 IBP medlab 2017/2018 OEM Modules for Patient Monitoring medizinische Diagnosegeräte GmbH etco 2 SpO 2 IBP OEM Modules for Patient Monitoring 2017/2018 medlab medizinische Diagnosegeräte GmbH 5 Contents Pulse Oximetry EG00352 Digital Miniaturized SpO 2 -Module 5 PEARL100 SpO 2 -Module with

More information

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is

More information

corpuls 3 Any Emergency under control

corpuls 3 Any Emergency under control corpuls 3 Any Emergency under control corpuls 3 The corpuls 3 offers an entirely new and revolutionary design concept compared with traditional compact defibrillator/ monitoring devices. It is designed

More information

Mini Digital Multimeter

Mini Digital Multimeter User's Guide Mini Digital Multimeter Model MN15 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech MN15/MN16 Series

More information

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter S-14 Compact Digital Multimeter S-14 Compact Digital Multimeter SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter

More information

Autoranging True RMS Multimeter User Manual

Autoranging True RMS Multimeter User Manual Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

ETHOS Auto Ranging Digital Multimeter

ETHOS Auto Ranging Digital Multimeter ETHOS 5020 Auto Ranging Digital Multimeter 1 1. SAFETY INFORMATION SAFETY SYMBOLS Warning! Dangerous Voltage (Risk of electric shock). Caution! Refer to the user s manual before using this Meter. Double

More information

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318 ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation

More information

Mini Digital Multimeter

Mini Digital Multimeter User Manual Mini Digital Multimeter Model MN15A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN15A MultiMeter. The MN15A offers

More information

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL SK-4033 / SK-4035 Thank you for purchasing KAISE MODEL SK-4033/4035 BENCH-TOP DIGITAL MULTIMETERS. To obtain the maximum performance of this instrument,

More information

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER SAFETY INFORMATION This multimeter has been designed according to IEC 1010 concerning electronic measuring instruments with an overvoltage category (CATⅡ)

More information

User's Guide. Digital Multimeter. Model MN42

User's Guide. Digital Multimeter. Model MN42 User's Guide Digital Multimeter Model MN42 Introduction Congratulations on your purchase of the Extech MN42 MultiMeter. The MN42 offers AC/DC Voltage, DC Current, and Resistance testing. Proper use and

More information

LIFEPAK 15 Test Calibration Procedure ( TCP)

LIFEPAK 15 Test Calibration Procedure ( TCP) This section contains the Test and Calibration Procedures (TCP). Perform the procedures in this section as necessary after replacing device components or to correct out-of-specification conditions detected

More information

Mini Digital Multimeter

Mini Digital Multimeter User's Guide Mini Digital Multimeter Model MN15 Introduction Congratulations on your purchase of the Extech MN15 MultiMeter. The MN15 offers AC/DC Voltage, AC/DC Current, Resistance, Diode, and Continuity

More information

STEP 2: VITALSBRIDGE TO PATIENT MONITOR CONNECTION GUIDE VITALSBRIDGE AND 100

STEP 2: VITALSBRIDGE TO PATIENT MONITOR CONNECTION GUIDE VITALSBRIDGE AND 100 STEP 2: VITALSBRIDGE TO PATIENT MONITOR CONNECTION GUIDE VITALSBRIDGE 300 200 AND 100 Basic Steps: 1. Connect power to the VitalsBridge 2. Turn the VitalsBridge on 3. Connect the VitalsBridge to your patient

More information

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

Model INSTRUCTION MANUAL DIGITAL MULTIMETER Model 57040 INSTRUCTION MANUAL DIGITAL MULTIMETER SAFETY INFORMATION This multimeter has been designed according to IEC 1010 concerning electronic measuring instruments with an overvoltage category (CAT

More information

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español Owner's Manual True RMS Multimeter Model No. 82023 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español

More information

*M C* Philips A1 and A3 Patient Monitors M3926A M3923A M3924A M3927A M3928A M3929A. Service Guide. Part Number M C

*M C* Philips A1 and A3 Patient Monitors M3926A M3923A M3924A M3927A M3928A M3929A. Service Guide. Part Number M C Philips A1 and A3 Patient Monitors A1 Models: A3 Models: M3921A M3922A M3923A M3924A M3926A M3927A M3928A M3929A Service Guide Part Number M3921-9000C Printed in the U.S.A. February 2002 First Edition

More information

Visit us at

Visit us at TM PRO3000 Toner and Probe Users Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com PN 2440799 (English) October 2005 2005 Fluke

More information

Mini Digital Multimeter Model MN15. User's Guide

Mini Digital Multimeter Model MN15. User's Guide Mini Digital Multimeter Model MN15 User's Guide Introduction Congratulations on your purchase of the Extech MN15 MultiMeter. The MN15 offers AC/DC Voltage, AC/DC Current, Resistance, Diode, and Continuity

More information

User Guide True RMS Multimeter Extech EX205T

User Guide True RMS Multimeter Extech EX205T User Guide Extech EX205T True RMS Digital Multimeter Extech EX210T True RMS Digital Multimeter IR True RMS Multimeter Extech EX205T Introduction Thank you for selecting the Extech EX205T True RMS Auto-ranging

More information

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389 User s Guide 600A True RMS AC/DC Clamp Meter Model 38389 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further

More information

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -... E39.0.1X.6C-01 Data logger for standard signals as of version 1.0 Operating Instruction T-Logg 120... T-Logg 120 W -... T-Logg 120 K -... GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße

More information

Model A Mini AC/DC Clamp Meter. User's Guide

Model A Mini AC/DC Clamp Meter. User's Guide Model 380950 80A Mini AC/DC Clamp Meter User's Guide Introduction Congratulations on your purchase of the Extech 80A Mini AC/DC Clamp Meter. The Model 380950 measures AC/DC Current, AC/DC Voltage, Resistance,

More information

MONITOR/DEFIBRILLATOR CONTROLS, CONNECTIONS AND INDICATORS

MONITOR/DEFIBRILLATOR CONTROLS, CONNECTIONS AND INDICATORS MONITOR/DEFIBRILLATOR CONTROLS, CONNECTIONS AND INDICATORS Adult Dose 100 120 70 170 50 200 30 20 15 1-10 CONTROLS, CONNECTIONS AND INDICATORS External Power SYNC Mark Event Lead Select Alarm Pause Event

More information

AutoRanging Digital MultiMeter

AutoRanging Digital MultiMeter Owner's Manual AutoRanging Digital MultiMeter Model No. 82175 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS GB Contents Page 1 Introduction 4 2 Safety 5 3 Use 6 4 Checking on Delivered Equipment 6 5 General Specification and Dimensions 7 6 Positioning 10 7 Operating

More information

METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no.

METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no. METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no. 20 751 979 Distributor: Manufacturer: METREL d.d. Ljubljanska cesta 77 1354 Horjul

More information

VS-600. Vital Signs Monitor. Service Manual

VS-600. Vital Signs Monitor. Service Manual VS-600 Vital Signs Monitor Service Manual Intellectual Property Statement SHENZHEN MINDRAY BIO-MEDICAL ELECTRONICS CO., LTD. (hereinafter called Mindray) owns the intellectual property rights to this

More information

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

More information

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www. Model R5010 TRMS Digital Multimeter Instruction Manual reedinstruments www com Table of Contents Safety...3-4 Features... 5 Specifications...5-8 Instrument Description...8-9 Operating Instructions...10-16

More information

Model 7705 Control Module

Model 7705 Control Module www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be

More information

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com CVU-3K-KIT 3 kv Bias Tee Kit Description The CVU-3K-KIT Bias Tee Kit consists of three bias tees for

More information

Modular Pre Hospital Defibrillation

Modular Pre Hospital Defibrillation Modular Pre Hospital Defibrillation Modular Lightweight Live Telemedicine Advanced Battery Technology 02 About Ortus With many years experience in the Emergency Service Sector, our high calibre management

More information

Ansur ProSim 6/8. Users Manual. Software Plug-In

Ansur ProSim 6/8. Users Manual. Software Plug-In Ansur ProSim 6/8 Software Plug-In Users Manual FBC-0002 April 2011, Rev. 2, 8/11 2011 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. Table of Contents

More information

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310 USER MANUAL Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310 Introduction Congratulations on your purchase of the Extech EX310 MultiMeter. The EX310 offers AC/DC Voltage, AC/DC Current,

More information

Digital Multimeter User's Manual

Digital Multimeter User's Manual Digital Multimeter User's Manual MS8238C MS8238C DIGITAL MULTIMETER FUNC HOLD RAN NCV TEMP V μa ma 12V 9V 1.5V CAT III COM FUSED 10A 30 sec. every 15 min. 200mA FUSED Autorange Auto power off TEMP maμav

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 E39.0.31.6C-02 Data logger for humidity temperature as of version V1.0 Operating Manual T-Logg 160 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0 +49 (0) 9402

More information

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314 Instruction Manual 2in1 LAN Tester & Multimeter Model: 57314 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.

More information

PCT2000. User Manual. Precision current transducer 2000 A

PCT2000. User Manual. Precision current transducer 2000 A PCT2000 User Manual PCT2000 Precision current transducer 2000 A User Manual Status: November 6, 2018 Copyright 2018 ZES ZIMMER Electronic Systems GmbH Pfeiffstraße 12 61440 Oberursel (Taunus), Germany

More information

700 Series 200 Amp Clamp Meters

700 Series 200 Amp Clamp Meters 700 Series 200 Amp Clamp Meters #61-700 #61-701 #61-702 1 2 3 6 5 7 4 8 1. Non-contact voltage (NCV) (#61-701 and #61-702) With the NCV tab on the tip of the clamp close to an AC voltage, press the NCV

More information

VS-900. Vital Signs Monitor. Service Manual

VS-900. Vital Signs Monitor. Service Manual VS-900 Vital Signs Monitor Service Manual Intellectual Property Statement SHENZHEN MINDRAY BIO-MEDICAL ELECTRONICS CO., LTD. (hereinafter called Mindray) owns the intellectual property rights to this

More information

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

Autoranging Multimeter plus IR Thermometer Extech 450 Patented User's Guide Autoranging Multimeter plus IR Thermometer Extech 450 Patented Introduction Congratulations on your purchase of the Extech 450 (part number EX450) Autoranging Multimeter plus IR Thermometer.

More information

Wa r n i n g-wa r n i n g-wa r n i n g

Wa r n i n g-wa r n i n g-wa r n i n g Installation Instructions of the Power Analyzer Wa r n i n g-wa r n i n g-wa r n i n g Read and understand this manual before connecting device. Death, fire or serious injury can occur from using equipment

More information

MOTOR ARMATURE TESTER

MOTOR ARMATURE TESTER MOTOR ARMATURE TESTER 6920 ENGLISH MANUAL 1 st Oct 2008 CATALOG BEFORE USE...1 1.1 Product Introduction...1 1.2 Product Characteristic...1 2 SPEC INSTRUCTION...2 3 SAFETY INSTRUCTION...4 4 INSTALLATION...6

More information

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com CVU-200-KIT 200 V Bias Tee Kit Description The CVU-200-KIT Bias Tee Kit consists of three 2600-RBT-200

More information

Autoranging Mini Multimeter

Autoranging Mini Multimeter User Manual Autoranging Mini Multimeter Model MN16A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN16A Autoranging Multimeter.

More information

CLEVELAND CONTROLS MODEL 6650 DIGITAL MANOMETER INSTRUCTION MANUAL DM

CLEVELAND CONTROLS MODEL 6650 DIGITAL MANOMETER INSTRUCTION MANUAL DM CLEVELAND CONTROLS MODEL 6650 DIGITAL MANOMETER INSTRUCTION MANUAL DM-6650.02 1 Instruction Manual DM-6650.02 TABLE OF CONTENTS I.0 INTRODUCTION 3 1.1 General Description... 3 1.2 Specifications... 3 1.3

More information

Model R5010. TRMS Digital Multimeter. Instruction Manual

Model R5010. TRMS Digital Multimeter. Instruction Manual INSTRUMENTS Model R5010 TRMS Digital Multimeter Instruction Manual Table of Contents Safety...3-4 IEC1010 Overvoltage Installation Category... 3 Warnings... 4 Features... 5 Specifications...5-8 Instrument

More information

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1 www.pce-industrial-needs.com Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co. Durham DH6 5PG United Kingdom Phone: +44 ( 0 ) 191 377 3398 Fax: +44 ( 0 ) 191 377 3357 info@tursdaletechnicalservices.co.uk

More information

Demonstration Case BENNING DB 1

Demonstration Case BENNING DB 1 Operating manual Demonstration Case BENNING DB 1 part no. 044132 Table of contents 1 Introduction...3 2 Safety instructions...4 3 Applicable regulations...5 4 Device description...5 4.1 Measuring / testing...

More information

Manual Supplement. Manual Title: ESA615 Users Supplement Issue: 2 Print Date February 2012 Date: 2/13 Revision/Date: 1 Page Count: 18

Manual Supplement. Manual Title: ESA615 Users Supplement Issue: 2 Print Date February 2012 Date: 2/13 Revision/Date: 1 Page Count: 18 Manual Title: Supplement Issue: 2 Print Date February 2012 Date: 2/13 Revision/Date: 1 Page Count: 18 This supplement contains information necessary to ensure the accuracy of the above manual. This manual

More information

POCKET MULTIMETER Model No: MM18

POCKET MULTIMETER Model No: MM18 INSTRUCTIONS FOR: POCKET MULTIMETER Model No: MM18 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained,

More information

1. Safety Precautions (Read these precautions before use.)

1. Safety Precautions (Read these precautions before use.) R P5102S/N/N1 HMI Installation Guide Thank you for purchasing FATEK HMI. Before installing or operating the unit, please read this installation guide carefully to ensure correct use. 1. Safety Precautions

More information

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals Martindale Electric will carry out routine calibration (on a chargeable basis) if the instrument is returned, carriage paid, to the address on the final page of this document. Alternatively, a chargeable

More information

PAT-Cal 2 TECHNICAL MANUAL

PAT-Cal 2 TECHNICAL MANUAL Portable Appliance Tester Calibrator PAT-Cal 2 TECHNICAL MANUAL 1 Time Electronics Limited Botany Industrial Estate, Tonbridge, Kent, TN9 1RH. Tel: +44(0)1732 355993 Fax: +44(0)1732 770312 Email: info@timeelectronics.co.uk

More information

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller), Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in

More information

Plasma Panel Replacement Guide DU-42PX12X

Plasma Panel Replacement Guide DU-42PX12X Plasma Panel Replacement Guide DU-42PX12X Panel Replacement: At this point, the panel has been determined to be defective and replacement is necessary. Upon receiving the replacement panel, it must be

More information

SERVICE MANUAL. NPB-4000/4000C Patient Monitor

SERVICE MANUAL. NPB-4000/4000C Patient Monitor SERVICE MANUAL NPB-4000/4000C Patient Monitor To contact Mallinckrodt, Inc. representative: in the United States, call -800-65-567: outside of the United States, call your local Mallinckrodt representative.

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

374 FC/375 FC/376 FC. Clamp Meter. Safety Information 374 FC/375 FC/376 FC Clamp Meter Safety Information 3-Year Limited Warranty. Go to www.fluke.com to register your Product, read the Users Manual, and find more information. A Warning identifies conditions

More information

1-36V, 0-3A DC Power Supply

1-36V, 0-3A DC Power Supply 1550 1-36V, 0-3A DC Power Supply User Manual Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be followed during all phases of operation, service,

More information

200B-G Tone Probe. 200EP-G Tone Probe INSTRUCTION MANUAL. with Adjustable Volume

200B-G Tone Probe. 200EP-G Tone Probe INSTRUCTION MANUAL. with Adjustable Volume INSTRUCTION MANUAL English...1 Français...9 Español...17 Deutsch...25 Italiano...33 Português do Brasil...41 200B-G Tone Probe with Adjustable Volume 200EP-G Tone Probe with Adjustable Volume, Visual Signal

More information

GMH Operating Manual for Digital Quick-Response Thermometer

GMH Operating Manual for Digital Quick-Response Thermometer H58.0.01.6C-02 Operating Manual for Digital Quick-Response Thermometer GMH 1170 WEEE-Reg.-Nr. DE93889386 GHM Messtechnik GmbH Standort Greisinger Hans-Sachs-Str. 26 D-93128 Regenstauf +49 (0) 9402 / 9383-0

More information

Power Over Fiber USER GUIDE. SYSTEM INSTALLATION INFORMATION Description. The leader in rugged fiber optic technology. RLH Industries, Inc.

Power Over Fiber USER GUIDE. SYSTEM INSTALLATION INFORMATION Description. The leader in rugged fiber optic technology. RLH Industries, Inc. USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-145 2018A-0119 Power Over Fiber SYSTEM INSTALLATI INFORMATI Description Our patented Power Over Fiber (PoF) system provides

More information

MONITOR/DEFIBRILLATOR CONTROLS, CONNECTIONS AND INDICATORS

MONITOR/DEFIBRILLATOR CONTROLS, CONNECTIONS AND INDICATORS MONITOR/DEFIBRILLATOR CONTROLS, CONNECTIONS AND INDICATORS 1-10 Adult Dose CONTROLS, CONNECTIONS AND INDICATORS External Power SYNC Mark Event Lead Select Alarm Pause Event Summary Soft Keys Soft Keys

More information

Operating Instructions PRO-AB /6.15. Leakage Current Measuring Adapter

Operating Instructions PRO-AB /6.15. Leakage Current Measuring Adapter Operating Instructions PRO-AB Leakage Current Measuring Adapter 3-349-621-15 3/6.15 Table of Contents Page 1 Scope of delivery...2 2 Safety Precautions...2 3 General...3 4 Preparing for Measurement...4

More information

Rigel Medical. Leaders in biomedical test solutions. Performance Analyzers. Vital Signs Simulators. Electrical Safety Analyzers

Rigel Medical. Leaders in biomedical test solutions. Performance Analyzers. Vital Signs Simulators. Electrical Safety Analyzers Innovating Together Rigel Medical Leaders in biomedical test solutions Performance Analyzers Vital Signs Simulators Electrical Safety Analyzers Asset Management Software Accessories Data traceability Test

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-796 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration

More information

ipm-9800 Patient Monitor Service Manual

ipm-9800 Patient Monitor Service Manual ipm-9800 Patient Monitor Service Manual Revision History This manual has a revision number. This revision number changes whenever the manual is updated due to software or technical specification change.

More information

Operating Instructions Differential Pressure Transducer PS27

Operating Instructions Differential Pressure Transducer PS27 Operating Instructions Differential Pressure Transducer PS27 halstrup-walcher GmbH Stegener Straße 10 79199 Kirchzarten/Germany Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-mail: info@halstrup-walcher.com

More information

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits

More information

FOCUS - ON - PATIENTS. corpuls aed

FOCUS - ON - PATIENTS. corpuls aed FOCUS - ON - PATIENTS corpuls aed FOCUS - ON - PATIENTS corpuls aed Advanced early defibrillation for specialists and non-specialists The new corpuls aed safely guides experts and non-experts through life-saving

More information

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL: IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL: 61-795 The Service Information provides the following: Precautions and safety information Specifications Performance test procedure Calibration and calibration

More information

imec12/imec10/imec8 Patient Monitor Service Manual

imec12/imec10/imec8 Patient Monitor Service Manual imec12/imec10/imec8 Patient Monitor Service Manual Intellectual Property Statement SHENZHEN MINDRAY BIO-MEDICAL ELECTRONICS CO., LTD. (hereinafter called Mindray) owns the intellectual property rights

More information

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24 Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24 Section Page Introduction 1 Materials Provided 1 I) Safety Instructions 1 A) Inverter Safety Instructions 1 B) Battery Safety

More information

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

9040/9040UK. Users Manual. Phase Rotation Indicator

9040/9040UK. Users Manual. Phase Rotation Indicator 9040/9040UK Phase Rotation Indicator Users Manual PN 2438546 April 2005 2005 Fluke Corporation. All rights reserved. Printed in China All product names are trademarks of their respective companies. LIMITED

More information

SBS -600 Graphical Digital Multimeter SBS- 700 Multi-Function Oscilloscope. Quick Start Guide

SBS -600 Graphical Digital Multimeter SBS- 700 Multi-Function Oscilloscope. Quick Start Guide SBS -600 Graphical Digital Multimeter SBS- 700 Multi-Function Oscilloscope Quick Start Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com

More information

Defibtech DDU-100 Semi-Automatic External Defibrillator

Defibtech DDU-100 Semi-Automatic External Defibrillator Defibtech DDU-100 Semi-Automatic External Defibrillator User Manual AHA /ERC 2010 U S E O N LY I F PA T I E N T I S : U N C O N S C I O U S U N R E S P O N S I V E N O T B R E A T H I N G 1 PUSH "ON" BUTTON

More information

Manual Supplement. Manual Title: ESA609 Users Supplement Issue: 7 Print Date: February 2014 Date: 2/19 Revision/Date: 1 Page Count: 13

Manual Supplement. Manual Title: ESA609 Users Supplement Issue: 7 Print Date: February 2014 Date: 2/19 Revision/Date: 1 Page Count: 13 Manual Title: Supplement Issue: 7 Print Date: February 2014 Date: 2/19 Revision/Date: 1 Page Count: 13 This supplement contains information necessary to ensure the accuracy of the above manual. This manual

More information

HI-POT TESTER User Manual

HI-POT TESTER User Manual HI-POT TESTER 7600 User Manual Contents 1. Safety...- 3-1.1 General...- 3 - AC Power Supply...- 4-1.2 Adjustment, Maintenance and Repair...- 5-1.3 Static Electricity...- 5-2. General:...- 6-2.1Packing

More information

709/709H. Calibration Manual. ma Loop Calibrator

709/709H. Calibration Manual. ma Loop Calibrator 709/709H ma Loop Calibrator Calibration Manual May 2013 2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective

More information

User Manual VX4234 Digital Multimeter Module

User Manual VX4234 Digital Multimeter Module User Manual VX4234 Digital Multimeter Module 070-9139-02 This document applies for firmware version 1.00 and above. General Safety Summary Review the following safety precautions to avoid injury and

More information

User's Guide. Digital Multimeter plus IR Thermometer. Extech 450 Patented

User's Guide. Digital Multimeter plus IR Thermometer. Extech 450 Patented User's Guide Digital Multimeter plus IR Thermometer 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Extech 450 Patented Introduction

More information

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System USER MANUAL Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System 614-06762-00 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for Line Interactive

More information

3700 SERIES USER MANUAL

3700 SERIES USER MANUAL SAFETY GUIDE This manual contains the precautions necessary to ensure your personal safety as well as for protection for the products and the connected equipment. These precautions are highlighted with

More information

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies ADC7520 SERIES 1600W Battery Chargers and Power Supplies Wide output adjustment range 0 72VDC Analog control by external 0-5VDC voltage Temp.comp charging, sense as on option Power fail relay alarm Master-Slave

More information

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E E39.0.0X.6C-03 Data logger for temperature as of version V1.3 Operating Manual T-Logg 100 T-Logg 100 T-Logg 100 E GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0

More information

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-820, IA001704 Mar. 2011 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information