Drawings. Model UT35A Digital Indicating Controller (UT35A-NNN-xx-xx/x) SD 05P01D41-05EN. External Dimensions. Panel Cutout Dimensions.

Size: px
Start display at page:

Download "Drawings. Model UT35A Digital Indicating Controller (UT35A-NNN-xx-xx/x) SD 05P01D41-05EN. External Dimensions. Panel Cutout Dimensions."

Transcription

1 Drawings SD PD-EN Model A Digital Indicating Controller (A-NNN-xx-xx/x) [Style: S] External Dimensions Unit: mm (approx. inch) 96 (.78) (.) 6 (.6) Bracket Terminal cover (.79) 96 (.78) 9.6 (.6) 9.6 (.7). (.) Bracket to mm (. to.9 inch) (panel thickness) Panel Cutout Dimensions General mounting 7 (.6) min. Side-by-side close mounting [(N ) 96+9] +.8 ([(N-).78+.6] ) (.6 ) () (.9) (.6 ) min. (.7) N stands for the number of controllers to be installed. However, the measured value applies if N (.6 ) () (.98) tolerance: ±(value of JIS B -998 tolerance grade IT8) / SD PD-EN rd Edition: Aug. (YK) P-

2 Terminal Wiring Diagrams Control output O (Suffix code: Output ; -T) E-terminal area - - PV input TC input Current (ma) input (Suffix code: Output =-P) Position proportional control output VALV Relay output HIGH (direct) LOW (reverse) Triac output Contact output ALM (Equipped as standard) External output (relay) Alarm- output (PV high limit) Alarm- output ( PV low limit) Alarm- output PV high limit Contact rating: V AC, A V DC, A (resistance load) AL AL AL Relay rating: V AC, A V DC, A (resistance load) Power supply - V AC power supply N L Triac Contact rating: 7 - V AC Allowable load current:.8 A Allowable range: - V AC (±%) (free voltage) /6 Hz shared (Suffix code: Output ; -R or -U and Output ; N or A) Relay output NC Feedback input % % Contact rating: V AC, A V DC, A (resistance load) Heating/cooling control output (Suffix code: Output and Output ; -UU, -UR, -RU or -RR. Terminal has no function in -AU and -AR.) O O Heating/cooling relay output Cooling -side Heating -side Contact rating: V AC, A V DC, A (resistance load) V AC/DC power supply N L Resistance: Ω to. kω Feedback input Current (ma) input + - PV (Equipped as standard) RTD input Voltage (mv, V) input A b B Factory default: PV input type is undefined. ( V AC/DC power supply: Optional suffix code /DC) CAION Do not use a - V AC power supply for the V AC/DC model; otherwise, the instrument will malfunction. When feedback input is current E-terminal area (Optional suffix code /RT) Retransmission output (Suffix code: Output ; A or U) Cooling-side control output Current/voltage pulse output RET/O - ma DC, - ma DC, Voltage pulse (V) 6 RET Retransmission output V DC loop power supply Default: PV retransmission - ma DC or.-8. V DC - ma DC (Max. ma DC) 6 6 Load resistance 6 Ω or less Default: - ma DC Contact input DI (Equipped as standard) No-voltage Transistor STOP when DI=ON DI DI RUN when DI=OFF DI AO when DI=ON DI MAN when DI=OFF Contact rating: V DC, ma or more Heater break alarm HBA (Optional suffix code /HA) External output (transistor) Heater current detection input Heater break alarm- HAL output CT Heater break alarm- HAL output CT Transistor rating: V DC, ma Can not be used for retransmission output or V DC loop power supply when current/voltage pulse output is used. Can be used for retransmission output or V DC loop power supply when control output is not used. Current output range can be changed. (Suffix code: Output ; -A or -U) Control output O Current/voltage pulse output Retransmission output Default: Undefined 7 - ma DC, 7 - ma DC, - ma DC, Voltage pulse ( V) - ma DC Default: - ma DC V DC loop power supply V DC (Max. ma DC) Can be used for retransmission output or V DC loop power supply when current/voltage pulse output is not used for control output. Current output range can be changed. In Position proportional type, can be used for retransmission output or V DC loop power supply. All Rights Reserved. Copyright 9-, Yokogawa Electric Corporation. SD PD-EN rd Edition Aug., -

3 Terminal Wiring Diagrams (E-Terminal Area) Contact input DI (Optional suffix code /X) No-voltage Transistor DI DI DI DI DI Contact rating: V DC, ma or more DI DI DI DI DI Function can be assigned to the terminals with no function. Contact output DO (Optional suffix code /Y) External output (transistor) DO DO DO DO DO Transistor rating: V DC, ma Function can be assigned to the terminal with no function. Contact input / Contact output DI/DO No-voltage Transistor DI DI DI DI (Optional suffix code /W) External output DO DO Contact rating: V DC, ma or more Transistor rating: V DC, ma E-terminal area E-terminal area All Rights Reserved. Copyright 9-, Yokogawa Electric Corporation. SD PD-EN rd Edition Aug., -

4 Terminal Wiring Diagrams (E-Terminal Area) E-terminal area - communication RS8 (Optional suffix code /CH) SDB(+) 7 SDA(-) 8 RDB(+) RDA(-) E-terminal area Ethernet communication (with gateway function) BASE-T/BASE-TX RJ connector Upper side LED (baud rate) Color Amber Lit M bps M bps Lower side LED (link activity) Color Lit Blink Green Linked Active Link failure ETHR (Optional suffix code /ET) RSA(-) 8 PROF (Optional suffix code /PD) PROFIBUS-DP communication (with Modbus master) VP RxD/TxD-P RxD/TxD-N DGND SHIELD LED Lit User profile error RDY Communicating (green) successfully ERR Not connected, or communication failure (flashing) VP Data 9Ω line RxD/TxD-P RDY Data Ω ERR line RxD/TxD-N 9Ω DGND bus power Data signal (positive data receive/transmit) Data signal (negative data recive/transmit) Signal ground Shield ground No power, or Communication failure If the is located at the end of a segment for the PROFIBUS terminating resistors are separately needed. These are to be prepared by users. (9 Ω: pcs. Ω: pc., or an active terminator.) RSA(-) 8 DNET (Optional suffix code /DN) DeviceNet communication (with Modbus master) LED MNS (green/ red) CAN_L V- Lit/flashing User profile error MNS CAN_H Ω CAN_L V+ CAN_H DeviceNet power supply V RX/TX + signal DRAIN Shield/Drain wire RX/TX - signal DeviceNet power supply common. Communicating successfully (green, lit). Not connected (green, flashing). Critical link failure (red, lit). Communication timeout (red, flashing) At power-on/communication faulted (green/red, flashing) No electricity If the is located at the end of a segment for the DeviceNet terminating resistors are separately needed. These are to be prepared by users. ( Ω: pc.) RSA(-) 8 CC-L (Optional suffix code /CC) CC-Link communication (with Modbus master) LED L ERR L RUN (green) Lit User profile error/ Address error L ERR L RUN Communication failure (CRC error) Communicating successfully DA DB Ω FG SLD Frame ground Shield DG RX/TX signal ground DB RX/TX- signal DA RX/TX+ signal No carrier detected/ Connection timeout If the is located at the end of a segment for the CC-Link terminating resistors are separately needed. These are to be prepared by users. ( Ω: pc.) RSA(-) 8 All Rights Reserved. Copyright 9-, Yokogawa Electric Corporation. SD PD-EN rd Edition Aug., -

5 Terminal Wiring Diagrams (E-Terminal Area) V DC loop power supply LPS (Optional suffix code /L) V DC loop power supply.6-8. V DC (Max. ma DC) Contact output DO (Optional suffix code /Y) External output DO DO E-terminal area E-terminal area DO DO DO Contact input DI (Optional suffix code /X) No-voltage Transistor DI Transistor rating: V DC, ma DI DI DI DI Function can be assigned to the terminals with no function. DI DI DI DI DI Contact rating: V DC, ma or more Function can be assigned to the terminals with no function. Contact input / Contact output DI/DO (Optional suffix code /W) No-voltage Transistor DI DI DI DI Contact rating: V DC, ma or more External output DO DO Transistor rating: V DC, ma All Rights Reserved. Copyright 9-, Yokogawa Electric Corporation. SD PD-EN rd Edition Aug., - Subject to change without notice.

Instruction Manual. Model US1000 Digital Indicating Controller. IM 5D1A01-01E 3rd Edition IM 5D1A01-01E

Instruction Manual. Model US1000 Digital Indicating Controller. IM 5D1A01-01E 3rd Edition IM 5D1A01-01E Instruction Manual Model US1000 Digital Indicating Controller 3rd Edition Introduction This instruction manual describes the general operation of the US1000 Digital Indicating Controller. Intended Readers

More information

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere!   Toll Free Digital Indicating Controllers JC Series High performance controllers...at the lowest prices anywhere! www.mod-tronic.com Toll Free 1-800 794-5883 Standard Features Structure Units available in standard

More information

Full Control at Your Finger Tips

Full Control at Your Finger Tips Full Control at Your Finger Tips Digital Indicating Controllers UT55A/UT52A/UT35A/UT32A Program Controllers UP55A/UP35A Digital Indicator with Alarms UM33A Bulletin 05P01A01-01EN www.utadvanced.com INTRODUCING

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET & DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

MIC-2 Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules

More information

FY Series Digital PID Controller Operation Manual FY400 FY700 FY800 FY900 FY600

FY Series Digital PID Controller Operation Manual FY400 FY700 FY800 FY900 FY600 FY Series Digital PID Controller Operation Manual FY101 90X90mm FY100 15X110mm FY400 FY00 FY800 FY900 FY600 48x48mm 2X2mm 48X96mm 96X96mm 96X48mm (DIN 1/) (DIN 3/) (DIN 1/8) (DIN 1/4) (DIN 1/8) February,

More information

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3] Single Loop Controller Series MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) 44 (5.67) 7 (.83) * mm (inch) *Selectable with option code /4: 400 mm /6: 600 mm Language blank: Japanese /E: English

More information

Modular controllers CECX

Modular controllers CECX Key features At a glance Versatile The controller is functionally designed as a master and motion controller. It is a powerful control unit that can Economical simultaneously execute both comprehensive

More information

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points) Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE

More information

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Warnings and legal information Installation and terminals Communication I/O options Alarming Utility software More information Specifications

More information

Digital Controller-Version II ES100X/P. Ordering Information. Intelligent Digital Controller and Programmer

Digital Controller-Version II ES100X/P. Ordering Information. Intelligent Digital Controller and Programmer Digital Controller-Version II Intelligent Digital Controller and Programmer Programmed with easy-to-use support software (ES Tools) or use front panel Use fuzzy fine-tuning to easily accomplish precise

More information

MODEL: GR8-EM. Communication Adaptor GR8 Series

MODEL: GR8-EM. Communication Adaptor GR8 Series Communication Adaptor GR8 Series Ethernet/RS-485 Adaptor (Modbus use) Functions & Features Bidirectional protocol converter for Modbus/TCP (Ethernet) and Modbus RTU (RS-485) Fast response time thanks to

More information

12.3 Fieldbus I/O Board

12.3 Fieldbus I/O Board 12.3 Fieldbus I/O Board 12.3.1 Overview of Fieldbus I/O The Fieldbus I/O option is an option to add fieldbus slave function (DeviceNet, PROFIBUS-DP, CC-Link, EtherNet/IP) to the robot Controller. A fieldbus

More information

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function MXIO Compact I/O module Summary The MXIO multiple I/O compact module is a microprocessor-controlled, communicative module with the I/O mix optimized for larger HVAC control applications. The module uses

More information

MGate 5118 Quick Installation Guide

MGate 5118 Quick Installation Guide MGate 5118 Quick Installation Guide Edition 1.0, December 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

isma-b-fcu FCU Hardware User Manual Global Control 5 Sp. z o.o. Warsaw, Poland

isma-b-fcu FCU Hardware User Manual Global Control 5 Sp. z o.o. Warsaw, Poland isma-b-fcu User Manual FCU Hardware Global Control 5 Sp. z o.o. Warsaw, Poland www.gc5.pl Table of contents 1 Introduction 3 1.1 Document change log 3 1.2 Safety rules 3 1.3 Technical specifications 4

More information

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North

More information

EL731 PROFIBUS INTERFACE

EL731 PROFIBUS INTERFACE Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/el731 EL731 PROFIBUS INTERFACE Revision 0-A-032816 Copyright 2016 Littelfuse Startco All rights reserved. Document Number: PM-1011-EN

More information

UT32A. Basic. control (*7) Functions 1 RS-485 communication (Max kbps, 2-wire/4-wire) (*1) Type 3: Option codes

UT32A. Basic. control (*7) Functions 1 RS-485 communication (Max kbps, 2-wire/4-wire) (*1) Type 3: Option codes Operation Guide IM 0P0D8E Contents. Safety Precautions. and Suffix Codes. How to Install. Hardware Specifications. How to Connect Wires 6. Terminal Wiring Diagrams 7. Setup Procedure 8. Operations 9. Troubleshooting

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

Paperless Recorder VGR-B100. Series

Paperless Recorder VGR-B100. Series Paperless Recorder VGR-B100 Series CE marking RoHS compliant Easy-to-Use! Paperless Recorder with Touch Screen VGR-B100 Easy Operation! Touch Screen Operation User friendly interface through a 5.7 inch

More information

icex-cmtm General specs and Installation guide

icex-cmtm General specs and Installation guide icex-cmtm General specs and Installation guide 1. General view 2. Specifications 2.1. Common specs: Ethernet 1 x 10/100Base/T, RJ45 connector with traffic and link LED Serial Interface 1 x RS232/485 USB

More information

UT32A/MDL UT32A. Basic control. Functions 1 RS-485 communication (Max kbps, 2-wire/4-wire) (*1) Type 3: Accessories (sold separately)

UT32A/MDL UT32A. Basic control. Functions 1 RS-485 communication (Max kbps, 2-wire/4-wire) (*1) Type 3: Accessories (sold separately) Operation Guide IM 0P0D8E Contents. Safety Precautions. and Suffix Codes. How to Install. Hardware Specifications. How to Connect Wires 6. Terminal Wiring Diagrams 7. Setup Procedure 8. Operations 9. Troubleshooting

More information

S800 I/O ABB Automation

S800 I/O ABB Automation S800 I/O 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 1 S800 I/O S800 I/O 3 : Fieldbus Communication Interface (FCI) I/O Module Module Termination Unit (MTU), Compact or Extended version 3BCNIIT F HW02-S800-V0102

More information

System Control Unit (SCU)

System Control Unit (SCU) ystem Control Unit (CU) Fieldbus coupler for Industrial Ethernet and Fieldbus standards Up to 28 input and 28 output variables can be assigned Easy integration in the process control system ensured through

More information

UT75A / UT55A / UT52A / UT35A / UT32A

UT75A / UT55A / UT52A / UT35A / UT32A Digital Indicating Controller UTAdvanced Digital Indicating Controller UT7A / UTA / UTA / UTA / UTA Program Controller UPA / UPA / UPA Digital Indicator with Alarms UMA Bulletin PA-EN www.utadvanced.com

More information

Remote I/O Modules EH-RIO2 Series

Remote I/O Modules EH-RIO2 Series Remote I/O Modules EH-RIO2 Series Fieldbus adapter: ProfiNET, EtherCAT, Modubus TCP / RTU, Profibus-DP, DeviceNet Separation of electronics module and terminal block for easy installation and maintenance

More information

Manual Fiber Optic Interfaces

Manual Fiber Optic Interfaces Manual Fiber Optic Interfaces Type 81210, 81211 61210, 61211 65210, 65211 41210 Release 1.4 Subject to error and alteration 31 06/2007 by Wiesemann & Theis GmbH Subject to error and alteration: Since it

More information

DIGITAL INDICATING CONTROLLER

DIGITAL INDICATING CONTROLLER DB1000 SERIES DIGITAL INDICATING CONTROLLER The DB1000 series is a 96 96mm digital indicating controller with the indicating accuracy of ±0.1% and the control cycle of approximately 0.1 seconds. Various

More information

EXOcompact. Third generation freely programmable controllers

EXOcompact. Third generation freely programmable controllers revision 1 013 EXOcompact Third generation freely programmable controllers Small, compact controller with different types of communication, with or without built-in display. EXOcompact can be used either

More information

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS ELK. ETK COMPACT BASIC CONTROL - SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS TIMER - SOFT START OUTPUT

More information

3G3FV SI-P Option Card for Profibus-DP Instructions 02/16/00

3G3FV SI-P Option Card for Profibus-DP Instructions 02/16/00 SI-P Option Card for Profibus-DP Instructions 02/16/00 - Contents - 1 Instruction... 3 1.1 Background... 3 2. Card Installation and set-up... 3 2.1 Option board overview. 3 2.2 Profibus-DP BUS connectors

More information

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions ICP DAS 2015 M2M WLAN Wireless Solutions Industrial Computer Industrial Product Data Computer Acquisition Product System Data Acquisition System PAC WLAN Wireless Solutions Wi-Fi Products WLAN Converter

More information

Process displays For current and voltage

Process displays For current and voltage Features Voltage input TRMS-AC/DC up to 600 V Current input AC/DC 1 A, 5 A and shunt (precision resistor) 60 or 100 mv With 2 or 4 limits Display range can be linearised Min, Max, Hold functions 4 20 ma

More information

Module Type Controller SRX Temperature Control Module for PROFIBUS X-TIO-G Instruction Manual

Module Type Controller SRX Temperature Control Module for PROFIBUS X-TIO-G Instruction Manual Module Type Controller SRX Temperature Control Module for PROFIBUS X-TIO-G Instruction Manual IMS01N0-E3 Thank you for purchasing this RKC product. In order to achieve maximum performance and ensure proper

More information

User s Manual. FX100(Desktop Type) IM 04L20A01-51E 1st Edition. Yokogawa Electric Corporation. Model FX103/FX106/FX112

User s Manual. FX100(Desktop Type) IM 04L20A01-51E 1st Edition. Yokogawa Electric Corporation. Model FX103/FX106/FX112 User s Manual Model FX103/FX106/FX112 FX100(Desktop Type) * 4 L 2 0 A 1 5 1 E 0 1 * Yokogawa Electric Corporation 1st Edition Forword Notes Trademarks Revisions Thank you for purchasing the FX100. This

More information

FACTORY AUTOMATION MANUAL CBX500 HOST INTERFACE MODULES

FACTORY AUTOMATION MANUAL CBX500 HOST INTERFACE MODULES FACTORY AUTOMATION MANUAL CBX500 HOST INTERFACE MODULES HOST INTERFACE MODULES With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

FX-485PC-IF RS485 Interface Unit Hardware Manual

FX-485PC-IF RS485 Interface Unit Hardware Manual JY992D81801B Date: 2015 April FX- RS485 Interface Unit Hardware Manual This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the

More information

Message Runner KP3H. Text Display. Small messages on your machine. Compact DIN 36 x 72 profile. Green and orange character display.

Message Runner KP3H. Text Display. Small messages on your machine. Compact DIN 36 x 72 profile. Green and orange character display. Message Runner KP3H Text Small messages on your machine This small and compact display is extremely well-suited for indicating a variety of short messages. Compact DIN 36 x 7 profile The compact DIN 36

More information

PAC BI-DP BIM and 8701-CA-BI Carrier

PAC BI-DP BIM and 8701-CA-BI Carrier June 2013 PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier PROFIBUS DP Bus Interface Module and Carrier The 8507-BI-DP Bus Interface Module (BIM) provides the communications link between the PAC8000 series

More information

Connecting a Cisco Output Module

Connecting a Cisco Output Module CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which

More information

ATV1200A kv kva

ATV1200A kv kva Characteristics medium voltage variable speed drive ATV1200-10 kv - 5000 kva Main Range of product Altivar 1200 Product or component type Device short name Product destination Product specific application

More information

ATV1200A kv kva

ATV1200A kv kva Characteristics medium voltage variable speed drive ATV1200-3.3 kv - 3500 kva Main Range of product Altivar 1200 Product or component type Device short name Product destination Product specific application

More information

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9) Characteristics medium voltage variable speed drive ATV1200-3.3 kv - 370 kva Main Range of product Altivar 1200 Product or component type Device short name Product destination Product specific application

More information

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7 M. K. Juchheim GmbH & Co UK USA Jumo Instrument Co. Ltd. Jumo Process Control Inc. 36035 Fulda, Germany Temple Bank, Riverway 735 Fox Chase Phone (0661) 6003-0 Harlow, Essex CM20 2TT Coatesville, PA 19320

More information

MGate 5111 Quick Installation Guide

MGate 5111 Quick Installation Guide MGate 5111 Quick Installation Guide Edition 1.0, December 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

Device/PLC Connection Manuals

Device/PLC Connection Manuals Device/PLC Connection Manuals About the Device/PLC Connection Manuals Prior to reading these manuals and setting up your device, be sure to read the "Important: Prior to reading the Device/PLC Connection

More information

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21.

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21. 0-CC 0-CC Order number 0-CC 0-CC Figure Type CC 0, Commander Compact CC 0DP, Commander Compact, PROFIBUS-DP slave General information Note - - Features x 0 characters, x 0 characters, Integrated PLC-CPU,

More information

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series Remote I/O R3 Series FL-net INTERFACE MODULE (OPCN-2, Ver.2. supported) Functions & Features FL-net (OPCN-2), Ethernet based, controller level network, compatible remote I/O 1 Mbps/1 Mbps cyclic transmission

More information

Masibus Automation And Instrumentation Pvt. Ltd.

Masibus Automation And Instrumentation Pvt. Ltd. Operator s Manual DIGITAL CONTROLLER 5006H Masibus Automation And Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Ph: 91 79 23287275-79 Fax: 91 79

More information

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Warnings and legal information Installation and terminals Communication I/O options Alarming Utility software More information Specifications

More information

Device/PLC Connection Manuals

Device/PLC Connection Manuals Device/ Connection Manuals About the Device/ Connection Manuals Prior to reading these manuals and setting up your device, be sure to read the "Important: Prior to reading the Device/ Connection manual"

More information

Connecting a Cisco Input Module

Connecting a Cisco Input Module CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each

More information

On-Machine Modular I/O

On-Machine Modular I/O ON-MACHINE MODULAR I/O On-Machine Modular I/O On-machine (IP67) modular I/O does not require an enclosure, allowing it to be mounted directly on the machine. TURCK on-machine modular I/O offers quick connection

More information

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control

More information

SINGLE-CHANNEL PROCESS INDICATOR series 8001

SINGLE-CHANNEL PROCESS INDICATOR series 8001 SINGLE-CHANNEL PROCESS INDICATOR series 8001 Analog Inputs - all inputs available in one unit - Pt100 RTD type DIN 43 760 or GOST 6651-78 (range from 0 to +600 C) - TC type: J - range from 0 to +600 C

More information

Single Loop Controller Models R35, R36

Single Loop Controller Models R35, R36 Specifications Single Loop Controller Models R35, R36 General Model R35/R36 is a digital indicating controller featuring multi-range inputs and PID control system using new algorithms "RationaLOOP PID

More information

RS-485 I/O Modules: ADAM-4000

RS-485 I/O Modules: ADAM-4000 RS-485 I/O Modules: ADAM-4000 23 ADAM-4000 Series Overview ADAM-4000 Series Remote Data Acquisition and Control Modules Overview 23-2 and Controller Module Selection Guide 23-4 I/O Module Selection Guide

More information

4 INSTALLATION. Installing the EZTouch Panel requires the following three major steps:

4 INSTALLATION. Installing the EZTouch Panel requires the following three major steps: Installing the EZTouch Panel requires the following three major steps: Mounting Connections and Wiring Communications Setup The EZTouch Panel is a front-panel mount unit. Mounting of the unit requires

More information

MGate 5105-MB-EIP Quick Installation Guide

MGate 5105-MB-EIP Quick Installation Guide MGate 5105-MB-EIP Quick Installation Guide Edition 2.2, March 2019 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System Features 10/100Mbps Ethernet full duplex Auto Negotiation Support C++/C Modbus/TCP drivers and OPC server Support configuration via built-in Web browsing, (HTML), Device Finder and I/O configuration utilities

More information

Version 1.0c May 6, 2010 ATK3

Version 1.0c May 6, 2010 ATK3 Version 1.0c May 6, 2010 ATK3 Contents 1 Hardware 2 1.1 Inputs............................... 2 1.2 Outputs.............................. 3 1.3 RS485............................... 3 1.4 Ethernet..............................

More information

RTD-W Installation Instructions

RTD-W Installation Instructions RTD-W Installation Instructions 0V +V POWER 15-24VDC 0V S1 S2 S3 0V S4 S5 S6 English RTD-W Installation Instructions 100.00 RTD-W Control Interface realtime Control Systems 24VAC/30VDC, 1A REMC P1 P2 RS485

More information

JUMO Quantum PID100/PID200/PID300

JUMO Quantum PID100/PID200/PID300 Data sheet 702020 Page 1/12 JUMO Quantum PID100/PID200/PID300 Universal PID Controller Series Brief description The Quantum series is available in the three DIN formats 48 mm x 48 mm, 48 mm x 96 mm, and

More information

PCIe Card Selection Guide. PCIe-CAN Card. PCIe-COM Card. Taiwan Pulse Motion Co.,Ltd. Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T

PCIe Card Selection Guide. PCIe-CAN Card. PCIe-COM Card. Taiwan Pulse Motion Co.,Ltd. Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T PCIe Card Selection Guide PCIe-CAN Card Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T Channels I/O Isolation Voltage Baud Rate Terminator Resistor I/O PIN Type 2 Max. 1 Mbps Jumper for 120

More information

Installation Manual. Multi Power Controller MPC-1 multi-line D

Installation Manual. Multi Power Controller MPC-1 multi-line D Installation Manual Multi Power Controller MPC-1 multi-line Complete control system in one package: - island operation - parallel with mains operation - emergency generator control 3-phase AC measurements

More information

TM241CEC24R controller M IO relay Ethernet CAN master

TM241CEC24R controller M IO relay Ethernet CAN master Characteristics controller M241 24 IO relay Ethernet CAN master Main Range of product Product or component type [Us] rated supply voltage Nov 28, 2017 Modicon M241 Logic controller 100...240 V AC Discrete

More information

Trajexia motion controller

Trajexia motion controller SP IM G AC SERVO DRIVER ADR 0 0 X10 X1 COM 1 3 3 2 9 8 6 7 5 1 4 2 SW1 SW2 CN2 CN1 A/B GRT1-ML2 TJ Trajexia motion controller Motion controllers Stand-alone advanced motion controller over MECHATROLINK-II

More information

JDICON 1001 Universal profile controller

JDICON 1001 Universal profile controller M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 60 03-0 Fax: +49 661 60 03-6 07 E-mail: mail@jumo.net Internet: www.jumo.de

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

SAI Active Universal Pro

SAI Active Universal Pro Universal Pro - Overview Universal Pro Professional versions of the Remote I/O System featuring IP67 protection The modules in the Universal Pro systems provide additional I/O and functional modules for

More information

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A)

Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A) Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M9813380120-A) 1.- BASIC INSTRUCTIONS 1.1.- Checks on receipt. This manual assists in the installation and handling of

More information

Module Type Controller SRX Temperature Control Module for DeviceNet X-TIO-J Instruction Manual

Module Type Controller SRX Temperature Control Module for DeviceNet X-TIO-J Instruction Manual Module Type Controller SRX Temperature Control Module for DeviceNet X-TIO-J Instruction Manual Thank you for purchasing this RKC product. In order to achieve maximum performance and ensure proper operation

More information

Addendum for 125B Bushealth Measurements

Addendum for 125B Bushealth Measurements Addendum for 125B Bushealth Measurements Introduction This Addendum contains information to extend the information presented in the Fluke 125B Users Manual. The purpose of this Addendum is to give more

More information

01348(N or G) MH** -- Material Handling (N or G) MH** -- Material Handling

01348(N or G) MH** -- Material Handling (N or G) MH** -- Material Handling MATERIAL HANDLING MANIFOLDS WITH DeviceNet INTERFACE 01348(N or G) MH** -- Material Handling 01351(N or G) MH** -- Material Handling Note: N = NPT ports G = BSPP ports SOL 14 SOL 12 Station #3 SOL 14 SOL

More information

This manual may not be reproduced in whole or in part by any means, without written permission of Accuenergy.

This manual may not be reproduced in whole or in part by any means, without written permission of Accuenergy. Copyright 2008 V1.10 This manual may not be reproduced in whole or in part by any means, without written permission of Accuenergy. The information contained in this document is believed to be accurate

More information

UNIVERSAL CURRENT CONVERTER

UNIVERSAL CURRENT CONVERTER UNIVERSAL CURRENT / VOLTAGE CONVERTER AC/DC Current / Voltage Analyzer The is the first CURRENT / VOLTAGE CONVERTER & ANALYZER ALL IN ONE - of the market. It allow you to connect all isolated current sensors.

More information

SYSMAC Remote Transistor Module

SYSMAC Remote Transistor Module 9 SYSMAC Remote Transistor Module Ultra-compact Remote I/O Modules to Match Most Applications 1 4-point, 8-point and 16-point models 1 4-point models measure 82 W x 32 D x 64.5 H mm; 8- and 16-point models

More information

General Specifications

General Specifications General Model I/O Module (for N-IO) GS 32P06K30-01EN GENERAL This General (GS) provides the hardware specifications of I/O module (for N-IO) that can be mounted on the Base Plate for N-IO I/O (S2BN1D,

More information

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS I-7520 RS-232 to RS-485 Converter I-7510 RS-485 Repeater RS-232 RS-485 I-7000 SERIES Common Specifications Isolation voltage: 3000VDC Speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115000 Dual watchdog

More information

Motors I Automation I Energy I Transmission & Distribution I Coatings. SymbiNet CFW-11. User s Manual

Motors I Automation I Energy I Transmission & Distribution I Coatings. SymbiNet CFW-11. User s Manual Motors I Automation I Energy I Transmission & Distribution I Coatings SymbiNet CFW-11 User s Manual SymbiNet User s Manual Series: CFW-11 Language: English Document Number: 10002033446 / 00 Publication

More information

USER S MANUAL. FX2N-32DP-IF Profibus-DP Interface Unit

USER S MANUAL. FX2N-32DP-IF Profibus-DP Interface Unit USER S MANUAL FX2N-32DP-IF Profibus-DP Interface Unit FX2N-32DP-IF Profibus-DP Interface Unit Foreword This manual contains text, diagrams and explanations which will guide the reader in the correct installation

More information

1.5 axis motion controller

1.5 axis motion controller Ver. CHARGE POWER CN3 CN CN SERVOPACK RUN RD MCW5 STS SD 6 +4V SGDH- Ver. CHARGE CN CN3 CN SERVOPACK POWER 0 MCW5 RUN STS RD SD 6 +4V R88A-MCW5-@.5 axis motion controller Advanced motion made perfectly

More information

General Specifications

General Specifications General Model I/O Module (for N-IO) GS 32P06K30-01EN GENERAL This General (GS) provides the hardware specifications of I/O module (for N-IO) that can be mounted on the Base Plate for N-IO I/O (S2BN1D,

More information

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type

More information

FACTORY AUTOMATION QUICK START GUIDE IC-KP-*

FACTORY AUTOMATION QUICK START GUIDE IC-KP-* FACTORY AUTOMATION QUICK START GUIDE IC-KP-* IDENTControl units With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products

More information

CSI 6300 SIS Overview

CSI 6300 SIS Overview Overview The Digital Overspeed Protection System is TÜV - certified according to IEC 61508:2010 and provides speed measurement and detection of rotational direction for rotating machines such as turbines,

More information

Single Loop Controller Model R15

Single Loop Controller Model R15 Specifications Single Loop Controller Model R15 General Model R15 is a 48 x 48mm compact digital indicating controller featuring group multi-range inputs and PID control system using new algorithms "RationaLOOP

More information

MELSEC STlite Series

MELSEC STlite Series MITSUBISHI ELECTRIC MELSEC STlite Series Modular Input/Output System Quick Start Guide Art. no.: 12062012 Version A MITSUBISHI ELECTRIC INDUSTRIAL AUTOMATION About this Manual The texts, illustrations,

More information

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems. MXPLC Compact PLC process station Summary The MXPLC is a programmable process station with integrated I/O module with the I/O mix optimized for larger HVAC control applications. The multi-interface process

More information

MIC-2 MKII Profibus module user s manual

MIC-2 MKII Profibus module user s manual DESCRIPTION OF OPTIONS Profibus module user s manual DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4189320031B Legal information

More information

Module Type Controller SRV. PROFIBUS Communication Instruction Manual IMS01P07-E3 RKC INSTRUMENT INC.

Module Type Controller SRV. PROFIBUS Communication Instruction Manual IMS01P07-E3 RKC INSTRUMENT INC. Module Type Controller SRV PROFIBUS Communication Instruction Manual RKC INSTRUMENT INC. IMS01P07-E3 Modbus is a registered trademark of Schneider Electric. SIMATIC is registered trademarks of SIEMENS

More information

SR Mini HG SYSTEM. FAREX SR Mini HG SYSTEM. General Description. Features. Up to 320 control loops* 2 in one system. Flexible installation

SR Mini HG SYSTEM. FAREX SR Mini HG SYSTEM. General Description. Features. Up to 320 control loops* 2 in one system. Flexible installation FAEX S Mini HG SYSTEM S Mini HG SYSTEM General Description The S Mini HG SYSTEM is a DIN-ail mounted multi-loop control system. This product consists of block-type compact modules so that the configuration

More information

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO DeviceNet/PROFIBUS-DP Adapter - User Manual REV 4.0 SiboTech Automation Co., Ltd. Technical Support: +86-21-5102 8348 E-mail:gt@sibotech.net Table of Contents 1 ABOUT THIS DOCUMENT...2 1.1 GENERAL... 2

More information

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROLS, INC. PCMNET Users Manual Revised 2/4/2005 2003-2005 Integrated Systems and Control. Inc. PO Box

More information

KTA-250 Anemometer Alarm Card

KTA-250 Anemometer Alarm Card Connects to Davis Instruments DS7911 Anemometer Monitor both the wind speed and direction Interface to PLCs using the Modbus protocol Communicate via RS232 or 2-wire RS485 Interface to PLCs/Instruments

More information

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) PC Recorders R1M Series PC RECORDER (contact input, 32 points) Functions & Features Industrial recorder on PC 32-point dry contact inputs Easy system expansion via Modbus RTU Recorded data exportable to

More information

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number Fieldbus Gateway RS-232 to PROFINET EPGG001 Part Number Easy handling Gateway from RS-232/422/485 interfaces to PROFINET With two Industrial Ethernet ports Technical Data Electrical Data Supply Voltage

More information