ASD-Multicom-X Expansion TB option unit Instruction manuall

Size: px
Start display at page:

Download "ASD-Multicom-X Expansion TB option unit Instruction manuall"

Transcription

1 E ASD-Multicom-X Expansion TB option unit Instruction manuall NOTE 1. Make sure that this instruction manual is delivered to the end user of the expansion TB unit. 2. Read this manual before installing or operating the inverter unit, and store it in a safe place for reference. (C)TOSHIBA Corporation 1999 All Rights Reserved.

2 E Safety Precautions On the inverter and in its instruction manual, important information is contained for preventing injuries to users and damages to assets and for proper use of the device. Read the instruction manual attached to the inverter along with this instruction manual for completely understanding the safety precautions and adhere to the contents of these manuals. Handling in general Never Disassemble Prohibited Mandatory Danger Never disassemble, modify or repair the inverter. Disassembling the inverter could cause electric shocks, fire or injuries. Request your TOSHIBA dealer for repairs. Do not remove connectors when the power is on. It could lead to electric shocks. Do not put or insert foreign objects such as waste cable, bars, or wires into the inverter. It could lead to electric shocks or fire. Do not splash water over the inverter. It could lead to electric shocks or fire. Wiring should be conducted after turning the inverter power off. Turn off the power immediately in case any abnormalities such as smokes, smells or abnormal noise are found. Neglect of these conditions could lead to fire. Ask your TOSHIBA dealer for repairs. Transportation and Installation Prohibited Mandatory Danger Do not install or operate the inverter if it is damaged or any part is missing from it. Operating the inverter in a defective condition could lead to electric shocks or fire. Ask your TOSHIBA dealer for repairs. Do not put any inflammable material near the inverter. It could catch fire if the inverter sparks because of a breakdown and the like. Do not install the inverter where it could be splashed with water and the like. It could lead to electric shocks or fire. Inverter must be used under environmental conditions prescribed in this instruction manual. Using the inverter under conditions not specified by the instruction manual could lead to breakdown. 1

3 E Warning Do not install the inverter in any place subject to vibrations or it could fall. Prohibited Otherwise it can cause injury to people. Wiring Mandatory Danger Be sure to perform the following preparatory work before proceeding to wiring. 1Turn the power off. Wait 10 minutes or more after turning the power off and confirm that the charge lamp (on the inverter) is extinct. 2Using a circuit tester that has a D.C. voltage measuring capacity of more than 800V, check to see that the voltage remaining in the D.C. main circuit (between PC and PA) is below 45V. Failure to do this preparation could lead to electric shocks. Tighten the terminal board fixing screws at the specified torque. Failure to do this could lead to fire. About operation Prohibited Danger Do not touch inverter terminals when they are energized even if the motor is halted. Touching terminals while the power is energized could lead to electric shocks. Do not wipe the body with a wet cloth. It could lead to electric shocks. Do not pull on the cable It could cause damage or error. About disposal of Inverter Mandatory Warning Dispose of the inverter as an industrial waste. Unless it is disposed of as an industrial waste, it will become risks for human injury. 2

4 Introduction E Thank you for purchasing the expansion TB option unit for industrial inverter TOSVERT VF-A7 and later series. By the use of this unit, the expansion of input/output terminal is possible. This instruction manual describes connecting method and usage of the expansion TB option unit. Read this manual carefully before using the unit. Keep this manual near at hand of the operator who uses the expansion TB option unit for future reference in the maintenance and inspection. Type of expansion TB option unit Revision number Without cable Model number of expansion TB option Expansion TB option Confirmation on accessories Following accessory parts are included in the expansion TB unit. Upon unpacking, confirm on the following parts. Expansion TB option unit (1) Instruction manual of expansion TB option (this manual) one (E ) MANUAL (1) Board for connecting options 3

5 Contents E I. NAME AND FUNCTION OF EACH SECTION Appearance Name of each section (terminal) CONNECTION TO THE INVERTER Connection to the inverter Wiring FUNCTIONAL DESCRIPTION Expansion analog monitor Voltage output (±output) Current output (0-20mA output) Adjustment parameter for analog monitor Function of expansion input terminal Binary/BCD input command Multi-function output terminal (relay output) EXTERNAL DIAGRAM SPECIFICATION WARRANTY

6 1. Name and function of each section E Following figure shows appearance and name of each section of the expansion TB option unit. 1.1 Appearance nverter connecting side Connector (left side) Voltage output Current output B1 detachable terminal block Phoenix MC1.5/15-ST-3.81 View when the cover is removed Analog monitor bit switch B2 detachable terminal block Phoenix MC1.5/6-ST-3.81 Sink/Source bit switch Connector for options SINK Terminal block cover B3 detachable terminal block Phoenix MSTBT2.5/6-ST-5.08 SOURCE Grounding terminal M3 screw terminal 5

7 E Name of each section (terminal) < Control signal terminal (TB1, TB2, TB3) > MON1 Monitor output 1 MON2 Monitor output 2 CC Common terminal for control signal B0 Binary input 0 B1 Binary input 1 B2 Binary input 2 B3 Binary input 3 TB1 B4 Binary input 4 B5 Binary input 5 B6 Binary input 6 B7 Binary input 7 B8 Binary input 8 / expansion input terminal 1 B9 Binary input 9 / expansion input terminal 2 B10 Binary input 10 / expansion input terminal 3 B11 Binary input 11 / expansion input terminal 4 B12 Binary input 12 / expansion input terminal 5 B13 Binary input 13 / expansion input terminal 6 TB2 B14 Binary input 14 / expansion input terminal 7 B15 Binary input 15 / expansion input terminal 8 P24 24V power supply CC Common terminal for control signal *1 TB3 R1A Programmable relay output 1 R1B Programmable relay output 1 R1C Programmable relay output 1 R2A Programmable relay output 2 R2B Programmable relay output 2 R2C Programmable relay output 2 *1: Connect this CC terminal to the CC terminal on the control board of the inverter. 6

8 2. Connection to the inverter E Connect the vector-option unit to the inverter according to the procedures below. 2.1 Connection to the inverter (1) Confirm that the all power to the inverter are turned off beforehand. Note: Wait 10 minutes or more after turning the power off and confirm that the charge lamp on the inverter is unlit. (2) Fixing the vector-option unit alone by using screws <When the vector-option unit is installed alone> Tighten M4x25 screws with M4 nuts to an attachment of optional add-on cassette (separately procured) to fix the unit as shown in the figure below. <When the unit is installed with another option> Read instructions of connection with options on the following page for installation. Same procedures apply when three options are installed together. (When plural options are installed, order of installation from the inverter side is not specified.) (Note) Determine the initial setting of the bit switch for internal signal before connecting options. Mount a board for option connection, then use M4x50 screws and M4 nuts to fix the options as shown below. (When three units of option are installed, use M4x75 screws.) (3) Fixing the unit to the inverter Method for fixing the unit to the inverter differs according to the type of inverter to which the unit is installed. Refer to the instruction manual of Attachment of optional add-on cassette. 7

9 E Connection with options When two or more optional add-on cassettes are used, connect them with reference to the following diagram. Mounting of relay board for connecting options Following the diagram below mount the board which is attached to the vector option unit onto the unit for connecting options. Insert a flat head screwdriver into the triangular section at the right side of the option unit and remove the small window cover. Relay board mounting guide Triangular mark on the side face Slide the relay board into the place according to the insertion guide. (Note) Engage the patterned section of the board with the metal pad section of the connector and insert the board in parallel. When the insertion angle inclines, remove the board once and try again. Engage the patterned section of the board with the metal pad section of the connector and insert the board in parallel. When the metallic parts of the relay board is touched with bear fingers, they oxidizes and the contacting failure occurs. Put on gloves for the work. Connecting two options Connect options with reference to the diagram below. Triangular mark on the side face Fit two option s positioning guides on both units and connect two units not to shift the connecting position of the relay board. Hold a triangular section on the side of the unit and engage the relay boards securely. (Connection is satisfactory when the click sound can be heard.) If there is a gap between the units, two boards are misaligned. Carry out the work again from the beginning. Option s positioning guide (two guides on top and bottom) 8

10 E Wiring When conducting wiring, follow the instructions below. Use shield wire for control signal line and ground the unit with shield wire. (Use twisted pair shield cable for wiring of the analog monitor output.) Applicable wire size TB1, TB2: 0.2 to 1.5 mm 2 TB3: 0.2 to 2.5mm 2 Peel off the end of the wire about 5mm (7mm for TB3). For connecting wires, use screwdriver that has a blade tip of 0.4mm thickness and 2.5mm width. (For TB3, use screwdriver that has a blade tip of 0.6mm thickness and 3.5mm width.) Tightening torque of the terminal block is 0.22 to 0.25 N m. (For TB3, tightening torque is 0.5 to 0.6 N m.) Never bind the signal line and main circuit connection wire together. Use 0.75mm 2 wire for the connection of CC terminal (or PGCC terminal) of the expansion TB option and CC terminal of the inverter. Use 0.75mm 2 wire for the connection of grounding terminal of the expansion TB option and that of the inverter. < Input/output terminal interface > Terminal code B0~ B15 MON1 MON2 Function Electrical specification Internal circuit Contact point input Changeover of sink or source Analog output terminal Sink input ON: 5V or less (5mAtyp) OFF: 11V or over or 0.5mA or less Source input ON: 11V and 2.5mA or over (30Vmax) OFF: 5V or less or 1.4mA or less Current output: 0 20mA Allowable load resistance: 750Ω or less Converter circuit Voltage output: ±10VDC Output impedance: 4.7kΩ R1A, B, C R2A, B, C Relay contact point output Configuration of 1C contact point 250Vac-2A (cosφ=1) 250Vac-1A (cosφ=0.4) 30Vdc-1A P24 24V power supply 24VDC-100mA (total of optional add-on cassettes is 200mA or less) CC Common terminal of control circuit (Connect CC terminals of expansion TB option and inverter each other.) Isoelectric potential terminal of control circuit 9

11 3. Functional description E In this section, functions added by the installation of this expansion TB option, on top of the standard inverter functions, are described. 3.1 Expansion analog monitor Analog signal of ±10V (maximum 13V) or of 0-20mA (4-20mA) output will be put out to the terminals MON1 and MON Voltage output (output) Remove the small window at right side of the option (use flat-head screwdriver) and change the position of the slide switch to [V] side. Be sure to turn off the power supply when changing the selection of the switch. View when the cover is removed. Analog monitor bit switch SW2: MON1 setting switch SW3: MON2 setting switch Sink / Source bit switch Voltage output Current output Install the ammeter that has a full scale of 0 to 1mAdc (both-ends needle swings) or 0 to 7.5Vdc (10Vdc)- 1mA (both-ends needle swing) or similar one. Wiring length should be 5 meters or shorter and use twisted shield wire Current output (0-20mA output) Remove the small window at right side of the option (use flat-head screwdriver) and change the position of slide switch to [I] side. Be sure to turn off the power supply when changing the selection of the switch. View when the cover is removed. Analog monitor bit switch SW2: MON1 setting switch SW3: MON2 setting switch Sink / Source bit switch Voltage output Current output 10

12 E Since 0-20mA converter circuit is not insulated electrically inside the board of expansion TB option, place an insulator between the board and the expansion terminal block board when the unit is coupled with the circuit of 24V or over for control. When the signal is received remotely, it should be observed that the sum of the DC resistance and the load resisitance of the electric wire will not go over 750Ω Adjustment parameter for analog monitor Parameter Title Function Adjustment range f672 f673 f674 f675 f678 f679 f680 Optional analog terminal 1 meter selection Optional analog terminal 1 meter adjustment Optional analog terminal 2 meter selection Optional analog terminal 2 meter adjustment Optional analog terminal 1 meter offset Optional analog terminal 2 meter offset Selection of code for option analog meter (Valid when the frequency data is selected.) 0 to 31 Refer to output data selection table for details 0 to 31 Refer to output data selection table for details to 60% to 60% Setting: The first meter, The second meter 0: Standard Standard (absolute value) (absolute value) 1: With code Standard (absolute value) 2: Standard With code (absolute value), 3: With code With code Default setting Note 1: Optional analog terminal 1 and 2 meter offset titled by f678 and f679 are the parameters that is necessary to use only the output of forward side and to put out 4-20mA output. Note 2: Frequency is output in absolute value in standard setting of Selection of code for option analog meter of f680. By setting this parameter, frequency can be output with plus or minus code added. Note 3: Adjustment method of analog monitor output is similar to the case of AM terminal meter selection (f670). Refer to the inverter instruction manual. 11

13 E Form of output Analog output becomes as follows according to the data form of selection of the first and second connection meter for option analog and the switch setting of the option and the offset setting of the parameter. Option switch ±10V 0-20 ma Data form Offset setting Output f678, f679 Actual output depends on adjustment. With code 0.0% ±10V and 0V are regarded as 0 point. (Normal setting) Absolute value, only the + code 50.0% 0V is output as 0 point. (Normal setting) Absolute value, -10V is output as 0 point. (Abnormal setting) ) 0.0% only the + code Absolute value, 0mA is output as 0 point. (Normal setting) ) 0.0% only the + code Absolute value, only the + code 20.0% 4mA is output as 0 point. (Normal setting) With code 0.0% 10mA is output as 0 point. (Abnormal setting) 12

14 Selection of the first and second connection meter for option analog (f672 f672, f674) E Setting value Output data Adjustment level Data form 0 Running frequency (a) f680 1 Running frequency command (a) f680 2 Current indication (b) With code 3 DC Voltage (b) + only 4 Output voltage (b) + only 5 After-compensation frequency (a) f680 6 Speed feedback (real-time value) (a) f680 7 Speed feedback (1 second filter) (a) f680 8 Torque (b) With code 9 Torque command (b) With code 10 Internal torque reference (b) With code 11 Torque current (b) With code 12 Exciting current (b) Absolute value 13 PID feedback value (a) Absolute value 14 Motor overload factor (OL2 data) (c) + only 15 Inverter overload factor (OL1 data) (c) + only 16 PBr overload factor (PBrOL data) (c) + only 17 PBr load factor (pulse duty) (c) + only 18 Input power (c) Absolute value 19 Output power (c) Absolute value 20 Peak output current (b) + only 21 Peak DC voltage (b) + only 22 Motor counter dummy PG (d) + only 23 Location pulse (d) + only 24 PR input (c) + only 25 VI/II input (c) + only 26 RX input (c) With code 27 RX2 input (c) With code 28 FM output (c) + only 29 AM output (c) + only 30 Fixed output for meter adjustment (c) + only 31 Analog output for communication (c) + only Adjustment level refers to the voltage which is put out to the next data and at time of fixed output (100%) for meter. (a) Maximum frequency (fh) (b) Panel display 150% (c) Panel display 100% (d) Special output (Internal counted value should be 100% at maximum.) Offset adjustment parameter (f678 f678, f679) This parameter is used when the bi-directional voltage output for plus and minus is not necessary or when the output which has offset such like a 4-20mA output is used. Zero point of analog output is determined by this parameter. Outline of adjustment example Desired output signal Hardware setting Offset setting f678, f679 Analog output (changes depending on the adjustment.) ±10V ±10V 0.0% -13V 0 13V 0-10V ±10V 50.0% 0 13V 0-20mA 0-20mA 0.0% 0mA 20mA 4-20mA 0-20mA 20.0% 4mA 20mA 13

15 E Adjustment method of analog monitor output (1) Current output (0-20mA output) Under the use of current output, method of output adjustment for analog monitor is the same as the case of "AM terminal meter selection" (f670). Refer to the instruction manual attached to the inverter. (2) Voltage output (±output) In the case of voltage output, meter adjustment under the condition of inverter halt cannot be set well unlike the case of current output and AM terminal meter selection, even when the fixed output for meter (30) is designated with the parameters "optional analog terminal meter selection" (f672 and f674). When the meter adjustment is difficult during the operation of inverter, try sending out the operation frequency command to the monitor, and the adjustment will be possible. Before attempting an adjustment, disconnect an output wiring of the inverter for the sake of safety, or ensure safe condition to avoid possible danger in the event when the inverter abruptly runs. When the analog monitor that is to be adjusted is being used for the manipulation of peripheral devices, terminate the operation of those devices and take necessary safety prevention. Adjustment example of monitor output 1 For this adjustment work, temporarily change the present parameter. Before changing the parameter, record the current set value. 1. Confirm that the inverter is in halt condition. 2. Select [1] (operation frequency command) in the parameter "optional analog terminal 1 meter selection" (f672). 3. Select [1] (coded only to No.1 meter) or [3] (coded both to No.1 and No.2) in the parameter "Selection of code for option analog meter" (f680). 4. Select [5] (operating panel input enabled) in the parameter "speed setting mode selection" (fmod). 5. Operate a panel and set 0Hz to the operation frequency command. 6. Adjust a zero point of the meter on the parameter "optional analog terminal 1 meter offset" (f678). 7. Operate a panel and set the operation frequency command to the maximum frequency (fh). When it is not possible to set operation frequency command to the maximum frequency (fh), first set the upper limit frequency (ul) to the same value of the maximum frequency (fh), then adjust the operation frequency command to the maximum frequency (fh). 8. Adjust the meter indication value in "optional analog terminal 1 meter adjustment" (f673). Types of adjustment level differ depending on the parameter "optional analog terminal 1 meter selection" (f672). See selection table listed on the previous page. (a) The maximum frequency (fh) will become the voltage value that is presently indicated. (b) 150% displayed on the panel will be the voltage value that is presently indicated. (c) 100% displayed on the panel will be the voltage value that is presently indicated. 9. Restore the operation frequency command on the panel to its original value. 10. Restore the speed setting mode selection (fmod) to its original value. 11. Restore the "Selection of code for option analog meter" (f680) to its original value. 12. Restore the optional analog terminal 1 meter selection (f672) to its original value. 13. If the upper limit frequency (ul) has been changed in the step of 7 above, restore it to the original value. 14

16 E Function of expansion input terminal Eight input terminals can be added. However when binary/bcd signal selection (f107) is used, terminals will function as the binary/bcd input terminals. Function is similar to that of the input terminals of the inverter, refer to the inverter instruction manual. Setting of the sink/source switch of the option should coincide with the setting of the inverter. If the setting differs, error trip of sink/source switching (E-10) will be actuated. Parameter Title Function Adjustment range Default setting f119 Input terminal selection #9 (terminal B8) f120 Input terminal selection #10 (terminal B9) f121 Input terminal selection #11 (terminal B10) f122 Input terminal selection #12 (terminal B11) f123 Input terminal selection #13 (terminal B12) f124 Input terminal selection #14 (terminal B13) f125 Input terminal selection #15 (terminal B14) f126 Input terminal selection #16 (terminal B15) f145 Input terminal #9 16 response time Selection Monitor Refer to the description on status monitor mode of inverter s instruction manual. Condition of input contact point can be monitored by input terminal information 2 and 3. When binary/bcd signal selection (f107) is used, information about B0 to B7 terminals of binary/bcd input terminal is displayed on input terminal information 2 and 3. Monitor When f107=0. When f107=1 to 8. Information on input terminal 2 Terminals B8 to B11 Terminals B0 to B3 Information on input terminal 3 Terminals B12 to B15 Terminals B4 to B7 15

17 E Binary/BCD input command Operation frequency and the like of the inverter can be set by the external contact point signal from programmable controller or relay sequence or other devices. Binary input BCD input Lowest digit bit Upper most digit bit (12bit) Upper most digit bit (16bit) The first digit The second digit The third digit The fourth digit Connect terminal CC of option and CC of inverter. 16

18 E Highly accurate frequency setting is possible by the binary or BCD input. By using the terminals B0 to B15 of expansion terminal, binary or BCD input is possible. When these terminals are used, they are exclusive to binary or BCD input. Parameter Title Function Adjustment range Default setting f107 Binary/BCD signal selection (Extended terminal add-on cassette option) 0: None 1: 12bit binary code 2: 16bit binary code 3: 3-digit BCD code 4: 4-digit BCD code 5: Reverse 12bit binary input 6: Reverse 16bit binary input 7: Reverse 3-digit BCD input 8: Reverse 4-digit BCD input f228 BIN2 reference point #1 0~100% 0 f229 BIN point #1 frequency -fh~fh 0.0 f230 BIN reference point #2 0~100% 100 f231 BIN point #2 frequency -fh~fh 80.0 f232 BIN reference point #1% -250%~250% 0 f233 BIN reference point #2% -250%~250% 100 Function Convert the input into 0 to 100 percent as shown in the table below and change the point setting (f228 to f233). Binary/BCD input selection Input data Percent conversion 0 0% 12bit binary input (f107=1, 5) Terminals B0 to B11 0FFFh 100% 0 0% 16bit binary input (f107=2, 6) Terminals B0 to B15 0FFFFh 100% 3-digit BCD input (f107=3, 7) Terminals B0 to B11 4-digit BCD input (f107=4, 8) Terminals B0 to B % 0% % 99.99% (Note) 0FFFh and 0FFFFh are expressed in hexadecimal notation. In decimal system, they will be 4095 and For example: Title Function Adjustment range Setting example f228 BIN2 reference point #1 0~100% 0 f229 BIN point #1 frequency -fh~fh 0.0 f230 BIN reference point #2 0~100% 100 f231 BIN point #2 frequency -fh~fh

19 E In the former table of point setting and when the input is done with 12bit binary, input of 0500h (1280) will be as follows. 0500h/0FFFh x 80Hz = 25.00Hz Title Function Adjustment range Setting example f228 BIN2 reference point #1 0~100% 0 f229 BIN point #1 frequency -fh~fh 0.0 f230 BIN reference point #2 0~100% 80 f231 BIN point #2 frequency -fh~fh 80.0 In above table of point setting and when the input is done with 4-digit BCD, input of 4500 (4-digit BCD) will be as follows. (4500) x 99.99% / 9999 x 80Hz / 80% = 45.00Hz Designation of input timing of binary/bcd data Input timing of the binary/bcd data can be designated from the binary/bcd input command (function number 86). Assign this function to the input terminals on the inverter. This function is validated by the input from the terminals not from the parameter operation command mode selection (cmod). By using this function, operation frequency of two or more inverters can be set successively by a single bit s setting circuit. Title Function Adjustment range Setting f111~118 Input terminal function selection to ,87 Input setting of 86 is positive logic and that of 87 is negative logic. Refer to the inverter s instruction manual. Cautions for 16bit binary input When using 16bit binary, note that resolution differs according to the parameter of point setting. 16bit resolution applies to the following setting, however the minimum setting resolution will be 0.01Hz for frequency and 0.01% for percentage. In case that the point conversion is selected to order than the following settings,13bit resolutions applies. In case that frequency point input is selected (for example of speed command selection). Title Function Adjustment range Setting f228 BIN2 reference point #1 0~100% 0 f229 BIN point #1 frequency -fh~fh 0.0 f230 BIN reference point #2 0~100% 100 f231 BIN point #2 frequency -fh~fh Arbitrary In case that percent point input is selected (for example of torque command selection). Title Function Adjustment range Setting f228 BIN2 reference point #1 0~100% 0 f232 BIN reference point #1% -250%~250% 0 f230 BIN reference point #2 0~100% 100 f233 BIN reference point #2% -250%~250% Arbitrary 18

20 E Multi-function output terminal (relay output) Two output terminals can be added. These output function as relay output. Function is similar to that of the output terminals of the inverter, so refer to the inverter instruction manual. Parameter Title Function Adjustment range Default setting f133 Output terminal selection #4 0~119 0(UL) f134 Output terminal selection #5 0~119 2(LL) f153 Output terminal #4 delay time 2to 200ms (in steps of 2ms) 2 f154 Output terminal #5 delay time 2to 200ms (in steps of 2ms) 2 f163 Output terminal #4 holding time 2to 200ms (in steps of 2ms) 2 f164 Output terminal #5 holding time 2to 200ms (in steps of 2ms) 2 19

21 4. External diagram Do not forget to reserve the space for the options at time of installation. E External diagram of add-on options / External dimension diagram of unit with option installed (unit: mm) Dimension of optional unit When installing optional add-on cassette, secure sufficient space on the right side and front of inverter body. Space necessary for installing the options is different according to the type of inverter. Refer to the instruction manual of inverter. Figure below shows the installation dimensions for VFA7 inverter. External dimensions for installing the unit (1) External dimensions for installing the unit (2) < 30kW or smaller unit > < 37kW or larger unit > When one cassette is installed, L=38.5mm When two cassettes are installed, L=63.5mm When three cassettes are installed, L=88.5mm 20

22 E Specification <Environment Specification> Item Specification Indoor, less than 1,000 m from the sea level. Use Environment No direct sunlight, corrosive or explosive gas, steam, cutting dusts or dusts, grinding solution, and grinding oil. Ambient Temperature -10 to +50 Storage Temperature -25 to +65 Relative Humidity 20 to 90 % (No condensation) Vibration 5.9m/s² or less < Control specification > Function Contact point input (Changeover of sink / source) Binary input BCD code input Multi-function programmable input 24V power supply Multi-function programmable analog output (changeover of current / voltage) Multi-function programmable relay contact output Specification 16 contact points (among all, 8 contact points can be changed to multi-function input terminal) Sink input ON : 5V or less (5mAtyp) OFF : 11V or over, or 0.5mA or less Source input ON : 11V and 2.5mA or over (30Vmax) OFF : 5V or less, or 1.4mA or less 24VDC-100mA (total of optional add-on cassette: 200mA or less) 2 circuits Current output: 0-20mA Allowable load resistance: maximum 750Ω Voltage output: ±10V (maximum±13v) Output impedance: 4.7kΩ 2 circuits for output of 1C contact point 250Vac-2A (cosφ=1) 250Vac-1A (cosφ=0.4) 30Vdc-1A 21

23 6. Warranty E TOSHIBA provides warranty with the product under the following conditions. If and when a trouble occurs on the option unit properly installed and handled within one year of delivery, and if the trouble is clearly attributable to defects inherent in our design and manufacture, the product will be repaired free of charge. The warranty covers only the delivered option unit. Even in the term of the warranty, repair/adjustment service will be charged for the following cases. 1) Fault or damage resulting from misuse, unauthorized modification or repair. 2) Fault or damage resulting from falling down of the product or traffic accident during transportation. 3) Fault or damage originating from fire, salt water/salty breezes, some kind of gas, arthquake, storm or flood, lightning, abnormal supply voltage, other natural disasters. 4) Fault or damage caused by improper use of this option unit as it is used for a purpose out of its original function. If there is another special warranty contracted for this option unit, the special warranty has priority over this warranty. 22

Optional add-on cassette Attachment Instruction manual

Optional add-on cassette Attachment Instruction manual E6580774 Optional add-on cassette Attachment Instruction manual 1. INTRODUCTION 3 2. CONNECTION TO THE INVERTER 4 2.1 Fixing the option alone 4 2.2 Connection to the inverter 6 3. SPECIFICATION 8 4. WARRANTY

More information

TOS-SN-1 Extended Panel Operation Manual

TOS-SN-1 Extended Panel Operation Manual Introduction TOS-SN-1 Extended Panel Operation Manual The Extended Panel (TOS-SN-1) for TOSVERT series inverter can be used for programming or monitoring, but does not contain internal memory. Please read

More information

TOSVERT VF-S11 built-in board option

TOSVERT VF-S11 built-in board option TOSVERT VF-S11 built-in board option Communication Instruction Manual LIU005Z NOTICE 1. Make sure that this instruction manual is delivered to the end user of LONWORKS Communication built-in option board.

More information

Remote Keypad Instruction Manual RKP002Z

Remote Keypad Instruction Manual RKP002Z Remote Keypad Instruction Manual RKP002Z NOTICE 1. Make sure that this instruction manual is delivered to the end user of Remote Keypad. 2. Read this manual before installing or operating the Remote Keypad.

More information

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION H Series PLC EH-150 Analog input module EH-AXH8M Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction manual and all the

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

Instruction Manual (Supplementary) Totally-Enclosed Box Type Inverter

Instruction Manual (Supplementary) Totally-Enclosed Box Type Inverter 2 Instruction Manual (Supplementary) Totally-Enclosed Box Type Inverter TOSVERT VF-S11 Thank you for purchasing a Toshiba Totally-enclosed box type TOSVERT VF-S11 series inverter. This Manual gives a supplementary

More information

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004 Version 1.0 Produced in Jan. 2004 Instruction Manual LCD monitor IV-08MP Thank you for purchasing the SHARP IV-08MP LCD monitor. Read this introductory instruction manual carefully to thoroughly familiarize

More information

TOSVERT VF-AS1/PS1 series EtherNet/IP option unit Instruction Manual IPE001Z

TOSVERT VF-AS1/PS1 series EtherNet/IP option unit Instruction Manual IPE001Z E6581582 TOSVERT VF-AS1/PS1 series EtherNet/IP option unit Instruction Manual IPE1Z NOTICE 1. Make sure that this instruction manual is delivered to the end user of EtherNet/IP option unit. 2. Read this

More information

FR-A8AR INSTRUCTION MANUAL

FR-A8AR INSTRUCTION MANUAL INVERTER Plug-in option FR-A8AR INSTRUCTION MANUAL Relay output function PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING RELAY OUTPUT 1 2 3 Thank you for choosing this Mitsubishi inverter plug-in option.

More information

ELV12 Series. Instruction Manual

ELV12 Series. Instruction Manual Instruction Manual TDK-Lambda BEFORE USING POWER SUPPLY UNIT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all warnings and cautions before using the unit.

More information

Conductive Level Controller

Conductive Level Controller Conductive Level Controller 61F-D21T-V1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at ON or OFF using self-holding circuits. Sensitivity adjustment

More information

INVERTER INSTRUCTION MANUAL. Analog output function Digital output function. Plug-in option FR-A7AY PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING

INVERTER INSTRUCTION MANUAL. Analog output function Digital output function. Plug-in option FR-A7AY PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING INVERTER Plug-in option FR-A7AY INSTRUCTION MANUAL Analog output function Digital output function PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING PARAMETER LIST EXTENSION ANALOG OUTPUT DIGITAL OUTPUT

More information

NIR Moisture Analyzer KB-30

NIR Moisture Analyzer KB-30 NIR Moisture Analyzer KB-30 Operation Manual Safety Precautions FPL950701 Improper use of the NIR moisture analyzer in violation of the following safety notes may result in death, injury or damage to property

More information

PIEZO FEEDER CONTROLLER

PIEZO FEEDER CONTROLLER PIEZO FEEDER CONTROLLER Instruction Manual Single-Function Type P212 P312 This Instruction Manual is applicable to Piezo Feeder Controller version 1 and later. Confirm the version information displayed

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

V E1B Snap-in I/O Module

V E1B Snap-in I/O Module V200-18-E1B Snap-in I/O Module The V200-18-E1B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

V E2B Snap-in I/O Module

V E2B Snap-in I/O Module V200-18-E2B Snap-in I/O Module The V200-18-E2B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

INVERTER INSTRUCTION MANUAL. Relay output function. Plug-in option FR-A7AR PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING RELAY OUTPUT

INVERTER INSTRUCTION MANUAL. Relay output function. Plug-in option FR-A7AR PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING RELAY OUTPUT INVERTER Plug-in option FR-A7AR INSTRUCTION MANUAL Relay output function PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING RELAY OUTPUT 1 2 3 Thank you for choosing this Mitsubishi Inverter plug-in option.

More information

OPC-VG1-PG / PGo. PG Interface Card for FRENIC-VG. Instruction Manual

OPC-VG1-PG / PGo. PG Interface Card for FRENIC-VG. Instruction Manual Instruction Manual PG Interface Card for FRENIC-VG OPC-VG1-PG / PGo Thank you for purchasing our PG interface card designed for the high-performance, vector control FRENIC-VG series of inverters. - Improper

More information

GENERAL PRECAUTIONS GENERAL DESCRIPTION... 6

GENERAL PRECAUTIONS GENERAL DESCRIPTION... 6 Cat.No I173E-EN-01 RX Inverter Expansion I/O Board 3G3AX-EIO21-ROE USER S MANUAL GENERAL PRECAUTIONS... 3 1 GENERAL DESCRIPTION... 6 2 INSTALLATION PROCEDURE... 7 2.1 INSTALLING THE EXPANSION I/O BOARD...

More information

V E1B Snap-in I/O Module

V E1B Snap-in I/O Module V200-18-E1B Snap-in I/O Module The V200-18-E1B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

ERNT-AQTX10 ERNT-AQT68AD-GH. User s Manual. Mitsubishi General-Purpose Programmable Logic Controller Renewal Tool Conversion Adapter.

ERNT-AQTX10 ERNT-AQT68AD-GH. User s Manual. Mitsubishi General-Purpose Programmable Logic Controller Renewal Tool Conversion Adapter. Mitsubishi General-Purpose Programmable Logic Controller Renewal Tool Conversion Adapter Model ERNT-AQT68AD-GH User s Manual ERNT-AQTX10 Model ERNT-AQT68AD-GH 50CM-D180033-A(0810)MEE SAFETY PRECAUTIONS

More information

User safety and equipment protection guidelines

User safety and equipment protection guidelines Snap-in I/O Module The V200-18-E1 plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. The module offers: 3 analog inputs 16 digital

More information

HIGH PERFORMANCE TRANSISTOR INVERTER TRUE TORQUE CONTROL SERIES

HIGH PERFORMANCE TRANSISTOR INVERTER TRUE TORQUE CONTROL SERIES HIGH PERFORMANCE TRANSISTOR INVERTER TRUE TORQUE CONTROL SERIES 12-BIT BINARY OPTION MANUAL January, 1996 Introduction Thank you for purchasing the 12-bit binary option kit for the Toshiba TOSVERT-130

More information

POCKET MULTIMETER Model No: MM18

POCKET MULTIMETER Model No: MM18 INSTRUCTIONS FOR: POCKET MULTIMETER Model No: MM18 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained,

More information

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd.

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd. WARNING Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd. CONTENTS 1. The company..2 2. Specifications.. 3 3. Package Contents..5 4. Installation, Fix and Transport..6

More information

PLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10)

PLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10) TEC (Peltier) Controller PLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10) Thank you for purchasing the TEC (Peltier) Controller PLC-24V10AL. Read these operating instructions carefully to ensure effective

More information

24/48/120 VAC Interface Card Instruction Manual

24/48/120 VAC Interface Card Instruction Manual 24/48/120 VAC Interface Card Instruction Manual Distributed by Ergonomic Partners Sales@ErgonomicPartners.com www.ergonomicpartners.com Tel: (314) 884-8884 April 2012 Part Number: -R2 Copyright 2012 Magnetek

More information

7032 Digital-Analog Multimeter

7032 Digital-Analog Multimeter 7032 Digital-Analog Multimeter OPERATOR S MANUAL CONTENTS: 1. Safety precautions and procedures 1 1.1. Preliminary 1 1.2. During Use 2 1.3. After Use.. 2 2. General Description. 3 3. Preparation for Use..

More information

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated

More information

Hardware Operation Manual for CLE1000 H2K CLE1000 H2V

Hardware Operation Manual for CLE1000 H2K CLE1000 H2V Variable ISI Channel CLE1000 Hardware Operation Manual for CLE1000 H2K CLE1000 H2V CLE1000 S2 CLE1000 A2 Rev 2.5 May 2015 Introduction... 2 Safety Instruction... 2 1. General... 4 Features... 4 2. Connectors

More information

Motorized Curtain Tracks Progress 50 Motor Set

Motorized Curtain Tracks Progress 50 Motor Set Troubleshooting Before you decide that the trouble is a malfunction, perform the following check. Condition Not operating Unstable operation Moves adversely and in opposite direction Operation speed is

More information

Analog Input Installation Manual

Analog Input Installation Manual Analog Input Installation Manual August 2011 Part Number: 144-23917 Copyright 2011 Magnetek 1. Preface and Safety Magnetek manufactures products used as components in a wide variety of industrial systems

More information

RS232C/RS485 Data can be easily monitored by LAN

RS232C/RS485 Data can be easily monitored by LAN KS SIGNAL CVERTER (AKS) RSC/RS8 Data can be easily monitored by LAN KS SIGNAL CVERTER FEATURES The connectors are located on the front panel. Easy to connect Easy to operate Can be connected to the LAN

More information

User's Guide. Phase Sequence and Motor Rotation Tester Model

User's Guide. Phase Sequence and Motor Rotation Tester Model User's Guide Phase Sequence and Motor Rotation Tester Model 480403 Introduction Congratulations on your purchase of the Extech Model 408403 Motor and Phase Rotation Indicator. This handheld instrument

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E PROGRAMMABLE CONTROLLER Technical Manual ARCT1F321E-2 2008.11 Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly,

More information

Stepper Motor Driver AD1131. Nippon Pulse Motor Co. Ltd.

Stepper Motor Driver AD1131. Nippon Pulse Motor Co. Ltd. Stepper Motor Driver AD1131 Nippon Pulse Motor Co. Ltd. Contents 1 Product Warranty 2 1.1 In the case of purchase from a supplier other than NPM..................... 2 1.2 Warranty period...........................................

More information

Resolver to Digital Expansion Board

Resolver to Digital Expansion Board Resolver to Digital Expansion Board Catalog No. EXB009A01 Installation and Operating Manual 6/98 MN1313 Table of Contents Section 1 General Information............................. 1-1 Introduction....................................

More information

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2 dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical

More information

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs The IO-DI8-TO8 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 digital inputs,

More information

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A Table of Contents 1. Important Safety Instructions... 2 2. Overview... 3 3. Product Functional Description... 4 3.1. Front Panel... 4 3.2. LCD Display Description... 5 3.3. Rear Panel... 6 3.4. Communication

More information

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide. Safety Instructions Before use Thank you very much for purchasing this product. This product is an interface box called "Connection & Control Box" for EPSON short throw projectors. For your safety, read

More information

VECTOR INVERTER -INSTRUCTION MANUAL- HIGH RESOLUTION ANALOG INPUT / EXTRA CONTACT INPUT / THERMISTOR INTERFACE FR-V5AX

VECTOR INVERTER -INSTRUCTION MANUAL- HIGH RESOLUTION ANALOG INPUT / EXTRA CONTACT INPUT / THERMISTOR INTERFACE FR-V5AX VECTOR INVERTER -INSTRUCTION MANUAL- HIGH RESOLUTION ANALOG INPUT / EXTRA CONTACT INPUT / THERMISTOR INTERFACE FR-V5AX Thank you for choosing the Mitsubishi vector inverter option unit. This instruction

More information

ICON SERIES ipool. Swimming Pool Pump Controller. User Manual

ICON SERIES ipool. Swimming Pool Pump Controller. User Manual ICON SERIES ipool Swimming Pool Pump Controller User Manual PREFACE Thanks for choosing our ipool swimming pool pump controller. ipool is an intelligent controller which is specifically designed for swimming

More information

JANOME DESKTOP ROBOT JR2000N Series. Operation Manual. <Setup> For Qualified Installer ONLY

JANOME DESKTOP ROBOT JR2000N Series. Operation Manual. <Setup> For Qualified Installer ONLY JANOME DESKTOP ROBOT JR2000N Series Operation Manual For Qualified Installer ONLY Thank you for purchasing the Janome Robot. *Read this manual thoroughly in order to properly use this robot. Be sure

More information

VM-11 SERIES MODEL VM-11B ACCELERATION INPUT VIBRATION SIGNAL CONDITIONER INSTRUCTION MANUAL. MANUAL No E1.8. Revised in Mar.

VM-11 SERIES MODEL VM-11B ACCELERATION INPUT VIBRATION SIGNAL CONDITIONER INSTRUCTION MANUAL. MANUAL No E1.8. Revised in Mar. MANUAL No. 29351E1.8 Published in Nov.1991 Revised in Mar.2006 VM-11 SERIES MODEL VM-11B ACCELERATION INPUT VIBRATION SIGNAL CONDITIONER INSTRUCTION MANUAL FOREWORD VM-11B For Use in Safety... Thank you

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is

More information

Ultra Slim Relays 24

Ultra Slim Relays 24 Ultra Slim Relays 24 Technical Data... 1 Specifications.2 Model Number Structure - Relays...3 Model Number Selection...4 Accessories...5 Safety Precautions...6 Ultra Slim Relays WERNER`s embody the latest

More information

V E5B Snap-in I/O Module

V E5B Snap-in I/O Module V200-18-E5B Snap-in I/O Module The V200-18-E5B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 18 isolated digital

More information

PRODUCT SPECIFICATION. PC Board Relays. Series.

PRODUCT SPECIFICATION. PC Board Relays. Series. PRODUCT SPECIFICATION PC Board Relays 26 Series www.wernerelektrik.com Technical Data... Specifications...2 Model Number Structure - Relays...3 Model Number Selection...4 Dimensions... 5-6 Accessories...7

More information

9040/9040UK. Users Manual. Phase Rotation Indicator

9040/9040UK. Users Manual. Phase Rotation Indicator 9040/9040UK Phase Rotation Indicator Users Manual PN 2438546 April 2005 2005 Fluke Corporation. All rights reserved. Printed in China All product names are trademarks of their respective companies. LIMITED

More information

INFORMATION AMPLIFIER TA-102 OPERATING INSTRUCTIONS TABLE OF CONTENTS

INFORMATION AMPLIFIER TA-102 OPERATING INSTRUCTIONS TABLE OF CONTENTS OPERATING INSTRUCTIONS INFORMATION AMPLIFIER TA-102 INFORMATION AMPLIFIER TA-102 MIC AUX POWER TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION... 4 3. EACH PART NAME AND FUNCTIONS Top

More information

User's Guide. Digital Multimeter. Model MN42

User's Guide. Digital Multimeter. Model MN42 User's Guide Digital Multimeter Model MN42 Introduction Congratulations on your purchase of the Extech MN42 MultiMeter. The MN42 offers AC/DC Voltage, DC Current, and Resistance testing. Proper use and

More information

Autoranging True RMS Multimeter User Manual

Autoranging True RMS Multimeter User Manual Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.

More information

Multi-Loader Parameter writer Instruction Manual PWU003Z

Multi-Loader Parameter writer Instruction Manual PWU003Z Multi-Loader Parameter writer Instruction Manual PWU003Z Notice 1. Make sure that this instruction manual is delivered to the end user of the inverter. 2. Read this manual before first using the communications

More information

PRO-1250D CT MID DIN rail three phase four wire energy meter.

PRO-1250D CT MID DIN rail three phase four wire energy meter. PRO-1250D CT MID DIN rail three phase four wire energy meter. 1.1 Safety instructions 1.2 Foreword 1.3 MID certificate 1.4 Performance criteria 1.5 Specifications 1.6 Basic errors 1.7 Description 1.8 Dimensions

More information

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1 IO-PT4 I/O Expansion Module 4 PT100 Inputs (-50 to 460 C) The IO-PT4 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 4 PT100 inputs

More information

VS-P Series. TDK-Lambda INSTRUCTION MANUAL

VS-P Series. TDK-Lambda INSTRUCTION MANUAL VS5P /75P /1P/ 15P Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the

More information

Table of Contents Product Overview Before using the product Installation Procedure... 5

Table of Contents Product Overview Before using the product Installation Procedure... 5 Table of Contents Table of Contents... 1 1. Product Overview... 5 2. Before using the product... 5 3. Installation Procedure... 5 4. S100 Product Size (Drive with Option)... 14 5. H100 Product Size (Drive

More information

High Speed Remote I/O Module

High Speed Remote I/O Module High Speed Remote I/O Module EXF-RC15 The Unitronics EXF-RC15 is a High Speed Remote I/O Module that offers three High Speed Counter inputs and four high speed outputs. Overall, the EXF-RC15 offers 9 digital

More information

Model VC-SHIELD Shield Box

Model VC-SHIELD Shield Box User s Manual Model 733062 VC-SHIELD Shield Box Yokogawa Electric Corporation IM 733062-01E 2nd Edition Introduction Thank you for purchasing the 733062 VC-SHIELD Shield Box. This user s manual contains

More information

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL SK-4033 / SK-4035 Thank you for purchasing KAISE MODEL SK-4033/4035 BENCH-TOP DIGITAL MULTIMETERS. To obtain the maximum performance of this instrument,

More information

Wireless LAN Connecting Adapter [BRP072B42] Installation Manual

Wireless LAN Connecting Adapter [BRP072B42] Installation Manual Wireless LAN Connecting Adapter [BRP072B42] Installation Manual Wireless LAN Connecting Adapter [BRP072B42] Installation Manual Website: http://www.daikinthai.com/wlan3/modbus For details on specifications,

More information

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY. QUICK START GUIDE I INTRODUCTION KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY 1.1. SCOPE OF MANUAL. This Quick Start Guide covers simple installation and local operation of the Kepco 100W,

More information

OPLC Installation Guide

OPLC Installation Guide Samba OPLC SM35-J-R20/SM43-J-R20 SM70-J-R20 SM35-J-T20/SM43-J-T20 SM70-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs

More information

DC I/O Conversion Module FA-TB32XY

DC I/O Conversion Module FA-TB32XY DC I/O Conversion Module FA-TB32XY User's Manual Thank you for purchasing FA Goods product. Before using, please read this User s Manual and the relevant manuals carefully to ensure correct use. SAFETY

More information

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs The IO-DI8-TO8 and IO-DI8-TO8-L are I/O expansion modules that can be used in conjunction with specific Unitronics OPLC controllers. The

More information

Variable Temperature Digital Solder and Testing Station

Variable Temperature Digital Solder and Testing Station Variable Temperature Digital Solder and Testing Station Model: DSTS User Manual To avoid electric shock or injury, read the following carefully before using. 1. This appliance is only for household use.

More information

FR-PU07 QUICK START MANUAL

FR-PU07 QUICK START MANUAL VARIABLE FREQUENCY DRIVE MODEL FR-PU07 QUICK START MANUAL 1. INTRODUCTION...3 1.1 SAFETY...3 2. APPEARANCE AND PARTS IDENTIFICATION...4 3. PARAMETERS TO BE CHECKED FIRST...4 4. FUNCTIONS...4 5. OVERVIEW

More information

V E62B Snap-in I/O Module

V E62B Snap-in I/O Module V200-18-E62B Snap-in I/O Module The V200-18-E62B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 30 isolated digital

More information

Operation Manual for VXC4000 VXC4000 V

Operation Manual for VXC4000 VXC4000 V Variable Crosstalk Coupler VXC4000 Operation Manual for VXC4000 K VXC4000 V Rev 1.0 August 2015 Introduction... 2 Safety Instruction... 2 1. General... 4 Features... 4 2. Connectors & Switches... 5 2 1

More information

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P dv/dt filter plus Voltage Peak Limiter Operating Instructions Mechanical installation 3 Electrical installation 4 Maintenance and servicing 5 Technical

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction ACOPOSinverter P74 User's Manual Version: 2.20 (August 2016) Model no.: MAACPIP74-ENG Original instruction All information contained in this manual is current as of its creation/publication. We reserve

More information

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

More information

Before using the product, thank you for using our MDLV-HP Pulse Encoder Interface Option Module. Safety Instruction

Before using the product, thank you for using our MDLV-HP Pulse Encoder Interface Option Module. Safety Instruction Before using the product, thank you for using our MDLV-HP Pulse Encoder Interface Option Module. Safety Instruction To prevent injury and danger in advance for safe and correct use of the product, be sure

More information

DANGER. Risk of fire, electric shock, and injury. DO NOT insert or drop any object in openings, this could cause unit failure or

DANGER. Risk of fire, electric shock, and injury. DO NOT insert or drop any object in openings, this could cause unit failure or LFS50A Series Instruction Manual Prior to Use Please read this instruction manual carefully. Please use product only as directed or severe damage to the product may occur. Not properly following these

More information

MTP INSTRUCTION MANUAL

MTP INSTRUCTION MANUAL DT-118B MTP INSTRUCTION MANUAL Pocket Autoranging Digital Multimeter 3 in 1 Model MTP-1025 Auto Ran ging DMM Hz% A OFF V AU TO PO WER OFF MTP Instruments Table of Contents Introduction Page 1 Features

More information

Quick Start Guide. 240 Series Cryogenic Sensor Input Module. 1 Model 240 Quick Start Guide

Quick Start Guide. 240 Series Cryogenic Sensor Input Module. 1 Model 240 Quick Start Guide Quick Start Guide 240 Series Cryogenic Sensor Input Module 1 Model 240 Quick Start Guide 2 Model 240 Quick Start Guide Safety Precautions Observe these general safety precautions during all phases of instrument

More information

Smart Grid Tie Microinverter User Manual

Smart Grid Tie Microinverter User Manual Smart Grid Tie Microinverter User Manual Thanks for choosing Smart Microinverters. Read the following instruction carefully before installation and operating, install and operate as specified by this user

More information

DC I/O Conversion Module

DC I/O Conversion Module DC I/O Conversion Module,FA-TB32XYH User's Manual Thank you for purchasing FA Goods product. Before using, please read this User s Manual and the relevant manuals carefully to ensure correct use. SAFETY

More information

Analog Monitor Installation Manual

Analog Monitor Installation Manual Analog Monitor Installation Manual Part Number: 144-23919 Copyright 2011 Magnetek 1. Preface and Safety Magnetek manufactures products used as components in a wide variety of industrial systems and equipment.

More information

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-820, IA001704 Mar. 2011 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter. www.sordselectric.com MA7200 Sensorless Vector AC Inverter Features and Benefits Sensorless Vector The MA7200 has precise speed and torque control for the most demanding system performance and simple set-up

More information

MT8050iE series. Installation Instruction (1) (2)

MT8050iE series. Installation Instruction (1) (2) MT8050iE series 3 Installation Instructions Installation Instruction Secure the operator panel in position, using all the fastening holes and the provided brackets and screws: (A) 1 Installation and Startup

More information

User Guide. Control Box. RoscoLED TM.

User Guide. Control Box. RoscoLED TM. RoscoLED TM Control Box User Guide This guide applies to the following RoscoLED Control Box models: RoscoLED Control Box 300W/Static White (293 22250 0000) RoscoLED Control Box 400W/VariWhite (293 22260

More information

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS OPERATING INSTRUCTIONS BASIC PA AMPLIFIER A-1031 A-1061 A-1121 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy

More information

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 8020-STC Kelvin Standard Triaxial Connector Card Description The Model 8020-STC Kelvin Standard

More information

The accessory described in this manual is a high quality product that has been carefully designed and manufactured to guarantee optimal performance.

The accessory described in this manual is a high quality product that has been carefully designed and manufactured to guarantee optimal performance. INTRODUCTION Thank you for choosing our product. The accessory described in this manual is a high quality product that has been carefully designed and manufactured to guarantee optimal performance. This

More information

M250 (M LL) Safety

M250 (M LL) Safety M250 SAFETY M250 (M250-60-2LL) Safety Important Safety Information This document contains important instructions to use during installation of the Enphase M250 Microinverter. To reduce the risk of electrical

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation

More information

User's Guide. Extech AM A AC Analog Clamp Meter

User's Guide. Extech AM A AC Analog Clamp Meter User's Guide Extech AM300 300A AC Analog Clamp Meter Introduction Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device measure AC Voltage and Current, DC Voltage, and Resistance.

More information

M215 (M215-60) Safety

M215 (M215-60) Safety M215 QUICK INSTALL GUIDE M215 (M215-60) Safety Important Safety Information This document contains important instructions to use during installation and maintenance of the Enphase M215 Microinverter. To

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

SINUS PENTA 6. ACCESSORIES 6.1. BRAKING RESISTORS APPLICATION TABLES 111/209

SINUS PENTA 6. ACCESSORIES 6.1. BRAKING RESISTORS APPLICATION TABLES 111/209 INSTALLATION. ACCESSORIES.. BRAKING RESISTORS... APPLICATION TABLES From size S to size S, inverters are supplied with a built-in braking module. The braking resistor is to be connected outside the inverter

More information

PAR-WT50R-E PAR-WR51R-E

PAR-WT50R-E PAR-WR51R-E Wireless Remote Controller and Receiver PAR-WT50R-E PAR-WR51R-E This manual explains installation of the PAR-WR51R-E wireless receiver and the PAR-WT50R-E wireless remote controller, and settings of these

More information

PS/IO Circuit Board Retrofit

PS/IO Circuit Board Retrofit S&C 6800 Series Automatic Switch Controls PS/IO Circuit Board Retrofit Table of Contents Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet....