ACX 700 Installation Guide. Technical Manuals Online! -

Size: px
Start display at page:

Download "ACX 700 Installation Guide. Technical Manuals Online! -"

Transcription

1 ACX 700 Installation Guide ACX 700 Installation Guide i

2 Version E Reproduction or distribution forbidden. Copyright 1997 by Andover Controls. Subject to change without notice. Order No Copyright 1997 Andover Controls Corporation 300 Brickstone Square Andover, Massachusetts All Rights Reserved. Published by the Engineering Department at Andover Controls Corporation. IMPORTANT NOTICE This product is subject to change without notice. This document does not constitute any warranty, express or implied. Andover Controls Corporation reserves the right to alter capabilities, performance, and presentation of this product at any time. ACX 700 Installation Guide ii

3 Preface The Andover Controls ACX 700 Installation Guide presents instructions for installing the ACX 700 access controller on an Infinet network. It first presents site preparation information and then step-bystep installation instructions. ACX 700 Installation Guide iii

4 ACX 700 Installation Guide iv

5 Contents Setting Up the ACX 700 Controller and Infinet Site/System Setup Requirements...2 Controller Dimensions and Weight...3 Power Requirements...3 Cable Limitations...4 Lightning Protection...4 Building Ground Requirements...5 Inspecting the Ground...6 Environmental Requirements...6 Enclosure Requirements...6 Special Wire for Card Reader Inputs...6 Special Wire for Keypad Inputs...7 Output Requirements...7 Input Requirements...8 Laying Out the Site Setup...9 Installing the ACX Parts Required...10 Mounting...10 Connecting the AC Power...15 Selecting the AC Input Voltage...16 Connecting the UPS Power Supply...17 Connecting the Power Indicating LED...18 Wiring the Infinet to the ACX Wiring the Infinet to the Infinity CX 9000 or Wiring Inputs...24 Supervisory Input Circuits...26 Wiring Door Switches...28 Andover Controls Corporation v

6 Wiring Motion Sensors/Exit Push Buttons...30 Wiring Other Two-Wire Inputs...32 Wiring Card Reader Inputs...32 Wiring Keypad Inputs...39 Wiring Outputs...40 Wiring Door Outputs...40 Connecting Modules to the Expansion Port...42 Wiring Power Supply for Modules...45 Powering Up the ACX Reset Button...48 Connecting the Battery...48 Connecting the Andover Controls Service Tool...49 Appendix A Underwriters Laboratories Requirements Appendix B Setting the Card Type Jumpers Locating the Card Type Jumpers...B-2 Setting Jumpers for ABA Cards...B-3 Setting Jumpers for Wiegand Cards...B-4 vi ACX 700 Installation Guide

7 Figures 1. Dimensions and Location of Mounting Holes in Cabinet Provided, in inches (mm) Dimensions and Location of Mounting Holes in Backplate, in inches (mm) Dimensions of ACX 700 on Backplate with EMX 190s, in inches (mm) Cover Plate of the ACX Metal Plate and Screw for Power Supply Wire Location of Power Indicating LED on Front Door of Cabinet Provided Power Indicating LED and Its Parts Inserting the External LED through Drilled Hole Infinet Cable Wiring Attaching the Infinet Cable to Infinity CX 9000 or Normally Closed Supervisory Inputs Normally Open Supervisory Inputs Wiring Ordinary Switch to DoorSwitch Input Wiring Switch with Built-in Resistor to DoorSwitch Input Functioning of DoorSwitch Input Wired to Supervisory Input Functioning of Passive Infrared (PIR) Motion Detector Switch Wired to Supervisory Input Wiring Diagram for Counter or Digital Input Connections Between Card Reader and Controller Wiring Wiegand Card Reader (Sensor Engineering) to Controller Connections Between Card Reader and Controller Wiring Proximity Wiegand Card Reader to Controller, with 12 VDC Power Supply Connections Between Card Reader and Controller Wiring Dorado ABA Card Reader to Controller...38 Andover Controls Corporation vii

8 24. Wiring Diagram for DOOR and AUX Form C Outputs if Normally Open Wiring Diagram for DOOR and AUX Form C Outputs if Normally Closed Wiring External and AC Power to Controller and Modules...46 B-1. Location of Card Type Jumpers...B-2 B-2. Jumpers for ABA Cards...B-3 B-3. Jumpers for Wiegand Cards...B-4 viii ACX 700 Installation Guide

9 Tables 1. Maximum Length Wire for Card Readers Connecting Jumpers for AC Input Voltages...16 Andover Controls Corporation ix

10 x ACX 700 Installation Guide

11 Setting Up the ACX 700 Controller and Infinet The ACX 700 is a building access controller that can control access to two doors. You can use it to control access through up to four doors by attaching two EMX 190 modules to the ACX 700. You may set up access through either Wiegand or ABA card readers, which read access cards, or security keypads, which accept access codes. You may also use both the card reader and the security keypad together, for extra tight security. This manual covers the following: Site/System Setup Requirements Installing the ACX 700 Powering Up the ACX 700 Warranty Registration Your warranty is effective for 18 months starting on the date the system is shipped. Warning All wiring and installations must comply with local, state, and national electrical codes. ACX 700 Installation Guide 1

12 Site/System Setup Requirements Before you proceed to install the system, you should map out where you plan to install each controller, terminal/workstation, and modem. When planning the sites, be aware of any electrical interference that may occur. You also need to be aware of cabinet dimensions, power requirements, cable limitations, and environmental requirements. Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions in this manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Note This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Avis Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada. 2 ACX 700 Installation Guide

13 Controller Dimensions and Weight Each ACX 700 is in. ( ) and weighs 17 lbs. (7.73 kg). Power Requirements Caution The ACX 700 should receive power from its own independent, unswitched circuit. You can choose to connect AC power or a 12 VDC uninterrupted power supply (UPS), but not both. Instructions for how to connect the 12 VDC UPS are included later, with the installation instructions. To maintain the UL listing of your system, you should use a power supply listed by UL under APHV. If you choose AC power, you can select an AC power supply voltage of 24 V, 115 V, or 230 V. You receive it set to 115 V. Instructions for selecting the power supply you want are included later, with the installation instructions. AC voltages you can select are as follows (each uses a 3 A slow blow fuse): 24 VAC 50/60 Hz 115 VAC 50/60 Hz 230 VAC 50/60 Hz The ACX 700 consumes 20 VA of power at 115/230 VAC and consumes 50 VA of power at 12 VDC/24 VAC. ACX 700 Installation Guide 3

14 Cable Limitations The maximum cable length for all buses is 4,000 ft. (1,200 m) at 19,200 baud (up to 32 Infinet controllers). You can extend buses beyond 4,000 ft. or put more than 32 Infinet controllers on less than 4,000 ft. by using the InfiLink 200 amplification module. Note You must use shielded cables for Infinet to ensure compliance with the Class A FCC limits and to provide reliable communications. Cables that form Infinet are 24-gauge (0.25 mm), single-twisted-pair, tinned, shielded copper wire. Use the following cables 1 or their equivalents: Brand Rex # H 9002 (single-pair) Anixter # 9J (single-pair plenum cable) The cable should have a nominal impedance of 100 Ohms and a nominal velocity of propagation of 78%. Capacitance of Infinet cable should be nominal, below 12.5 pf/ft (41 pf/m) between conductors and below 22 pf/ft (72 pf/m) between the conductor connected to ground and the next conductor. Lightning Protection Lightning Arrestors are required at each point where an Infinet or other wiring (such as for a card reader) enters or exits a building. Use the following arrestor: Two pair combination gas tube/silicon avalanche arrestor, Andover Controls # You can also use any cables you may already have in place for ACNET or LBUS. 4 ACX 700 Installation Guide

15 Building Ground Requirements Warning Be sure that all Infinity products from Andover Controls Corporation are grounded to true earth ground. This kind of ground protects the equipment from transients and other power surges in the area. We cannot guarantee that the controller system will operate as documented unless you properly ground all controllers. Warning Grounding should be in accordance with article 240 of the National Electrical Code. Be sure to have your grounds inspected before you begin the installation process to be sure your municipality follows the National Electrical Code. Many municipalities do not and often have substandard electrical grounds. An example of a substandard ground is a galvanized steel cold water pipe. As the pipe corrodes, it does not act as a true ground. The corrosion acts as an insulator, raising the potential of the pipe with respect to the ground. When lightning strikes in the area of the installation, it drastically changes the potential of the earth. Since properly grounded Andover Controls units respond to changes in potential more rapidly than poorly grounded electrical systems, a poorly grounded building tries to reach ground through the Andover Controls system. The surge of current can destroy electronic components on the controller board. Surges of much lower potential than lightning also impact the reliability of Andover Controls equipment. ACX 700 Installation Guide 5

16 Inspecting the Ground You can check your ground as follows: 1. Check your ground by first inspecting the building power distribution panel for earth ground termination. If the ground termination is any of the following, it is not adequate and must be corrected: Does not exist. Is connected to a corroded or galvanized pipe. Is connected using a small gauge wire thinner than 14 AWG (16 or 18 AWG, for example, or less than 2.5 mm 2 ). 2. Be sure your Andover Controls cabinet is connected to the ground with a copper conductor that terminates at the distribution panel. Environmental Requirements The ACX 700 operates in rooms with temperatures ranging from 32 to 120 F (0 to 49 C) and with humidity between 10 and 95%, noncondensing. Enclosure Requirements If you did not purchase the Andover Controls cabinet, you purchased the open class controller. The open class controller must be in an Underwriters Laboratories listed enclosure that is a minimum of in. ( mm). Special Wire for Card Reader Inputs We recommend a five-conductor, 22-gauge (0.35 mm 2 ) shielded wire for wiring card reader inputs. Table 1 shows the various card brands and the maximum length for #18 gauge wire (1.0 mm 2 ), then for #22 gauge (0.35 mm 2 ) wire. 6 ACX 700 Installation Guide

17 Table 1. Maximum Length Wire for Card Readers Card Reader Type #18 Gauge (1.0 mm 2 ) #22 Gauge (0.35 mm 2 ) Sensor Engineering * 500 ft (152 m) 200 ft (60 m) Proximity (12V at ACX 700) 250 ft (76 m) 100 ft (30 m) Proximity (12V at Reader) 500 ft (152 m) 350 ft (106 m) Dorado ABA Card Reader 500 ft (152 m) 200 ft (76 m) * Model number for UL listed systems. Special Wiring for Keypad Inputs We recommend eight-conductor, 18-gauge shielded wire for wiring keypad inputs except for the Essex unit, which requires two extra wires bringing its total to ten conductors. 8-conductor, shielded 10-conductor, shielded for Essex Touch Pads You can extend the length of this cable up to 500 ft. Output Requirements Two of the outputs are door outputs that control a door through a card reader or keypad access. Each output is a Form C relay rated at 24 VAC, 5 A. You wire these outputs just as you would a digital/pulsed output. Resolution of the output is 0.1 sec. You may choose to manually override the output by setting the OVERRIDE switch to ON or OFF. Or you can set it to AUTO to have the card reader control access through the door. The OVERRIDE LED indicates at least one of the door outputs is on manual control; the DOOR OPEN LED indicates the door is open. The third output is an auxiliary output, also a Form C relay rated at 24 VAC, 5 A. You may want to use this output for a bell or other audio alarm indicator. ACX 700 Installation Guide 7

18 Input Requirements Caution Andover Controls inputs are designed to be used with the specified card readers, two-wire door switches, two-wire motion sensors, and other two-wire input devices; they do not provide sufficient power to operate sensors requiring an external power supply of 12 or 24 VAC/DC. Each ACX 700 controller has the following inputs: Two card reader inputs that receive either the Wiegand format or the standard ABA format. You set the switch next to each reader to indicate Wiegand or ABA. You may also have additional card readers by attaching one or two EMX 190 modules to the ACX 700. The card reader may have an LED, but does not have to. (UL listed systems must use model Sensor Engineering card readers.) Maximum data rate for the card reader 1 ms between bits with a 50 µs bit width. Maximum power available to each card reader is 35 ma at 5 VDC. If the card reader requires 12 ± 2 or 24 ± 2 VCD, it requires an external power supply. Eight supervisory inputs (1 through 8) that you can use for any of the following types of inputs: Door switch that indicates the status of the door open or closed. Must have a 10 KΩ resistor in series if normally closed or in parallel if normally open. The resistor allows the input to detect tampering. Refer to the Infinity CX Programmer s Guide for details. Required. An exit request input, usually a motion sensor that determines someone is approaching the door or a push button that you must press to leave the area. Must have a 10 KΩ resistor in series if 8 ACX 700 Installation Guide

19 normally closed or in parallel if normally open. The resistor allows the input to detect tampering. Refer to the Infinity CX Programmer s Guide for details. Optional. Two keypads, each a single input (inputs 9 and 10), that you place near the door as an alternative to a card reader. The person punches in an access code that the controller recognizes before allowing the person access. You may have up to two keypads and/or two card readers. Each keypad has eight connections. One built-in tamper switch that indicates when the cabinet door has been forced open. The switch is actually a button that reacts when someone opens the cabinet door. You may also wire another switch to the input if you install the unit in another cabinet. When the switch is open, the cabinet tamper is ON. Laying Out the Site Setup You may want to draw a map of where you plan to put each controller and store it in a notebook. Find the tag attached to each controller that gives the number of the controller. Before you remove any tags, be sure the tag has all of the following information on it: Location of the controller. Serial number. Model name and number. Communications port the Infinet connects to on the ACX 700 controller. Then collect the tags. You will need to know where your controllers are located when you later assign a name to each controller and each input and output. ACX 700 Installation Guide 9

20 Installing the ACX 700 Parts Required To install a single controller you start with the following parts: ACX 700 Controller (with or without cabinet) AC Power Cable or 12 VDC UPS Power Supply and Cable Input and Output Wires Up to Two Card Readers and/or Two Keypads Up to Two Door Switches Up to Two Motion Sensors or Two Exit Buttons (or One of Each) LED with Wires Attached and Screws/Washers Included (if you purchased the open class controller, without the Andover Controls cabinet) (optional) One Cabinet Door Tamper Switch (optional) Infinet Cable (twisted pair) InfiLink 200s as Hubs, Repeaters, or Cable Switching Boxes as required Up to two EMX 190 Modules (optional) Mounting Caution You must keep the ACX 700 in the UL listed enclosure provided or insert it in a UL listed enclosure. 1. Before you begin, if you have the enclosed unit, open the front door of the ACX 700 cabinet. Figure 1 shows the dimensions of the UL listed cabinet provided by Andover Controls and the location of the mounting screw holes. Figure 2 shows the dimensions of the open class UL listed unit and the dimensions of the backplate for mounting. 10 ACX 700 Installation Guide

21 Figure 1. Dimensions and Location of Mounting Holes in Cabinet Provided, in inches (mm) 1.33 (34) (381) (314) 1.00 (25) +12VDC -INPUT IN1 RET1 IN2 RET2 IN3 RET3 IN4 RET4 IN5 RET5 IN6 RET6 IN7 RET7 IN8 RET8 EXT TAMPER SWITCH +5V LED I/DATA O/CLK GND AC INPUT GND NEU HOT TAMPER SWITCH 9 AC INPUT VOLTAGE SELECTION 24V 115V 230V FROM E6 E4 TO E7 E3 FROM TO FROM E6 E5 -- E4 E2 E4 TO -- E5 P1 E1 P1 P1 E2 E1 PWR ON SUPERVISORY INPUTS ABA RESET WIEGAND READER 1 USE COPPER CONDUCTORS ONLY F1 3A,250V SLOW BLOW CPU + - B1 3.6V 1.8AHr LITHIUM ACX700 OVERRIDE AUTO/OFF/ON KEYPAD 1 KEYPAD 2 C1 C2 C3 R1 R2 R3 R4 RET C1 C2 C3 R1 R2 R3 R4 RET DOOR 1 OUTPUT (483) (432) +5V LED I/DATA O/CLK GND + SHLD READER 2 ABA WIEGAND INFINET TD RD +24VDC CLASS ma DOOR AUTO/OFF/ON OUTPUT AUTO/OFF/ON OUTPUT 3 SERVICE PORT EXPANSION PORT OVERRIDE Caution Never drill holes in the ACX 700 cover or boards. A metal shaving could easily short circuit the electronics. ACX 700 Installation Guide 11

22 2. Position two standard No. 8 screws for the pre-cut eyelets in the cabinet or backplate, and hang the cabinet or backplate on the screws. Figure 2. Dimensions and Location of Mounting Holes in Backplate, in inches (mm) R.117 (3) (318) (298).45 (11) AC INPUT GND NEU HOT USE COPPER CONDUCTORS ONLY AC INPUT VOLTAGE SELECTION 24V 115V 230V FROM TO FROM TO FROM E6 E7 E6 E5 -- TO -- E2 E4 E3 E4 E4 E5 P1 E1 P1 P1 E2 E1 ACX700 R.195 (5) +12VDC -INPUT IN1 RET1 IN2 RET2 IN3 RET3 IN4 RET4 IN5 RET5 IN6 RET6 IN7 RET7 IN8 RET8 EXT TAMPER SWITCH +5V LED I/DATA O/CLK GND TAMPER SWITCH 9 PWR ON SUPERVISORY INPUTS ABA RESET WIEGAND READER 1 F1 3A,250V SLOW BLOW CPU + - B1 3.6V 1.8AHr LITHIUM OVERRIDE AUTO/OFF/ON KEYPAD 1 KEYPAD 2 C1 C2 C3 R1 R2 R3 R4 RET C1 C2 C3 R1 R2 R3 R4 RET DOOR 1 OUTPUT (362) (292) +5V LED READER 2 I/DATA O/CLK ABA GND + WIEGAND INFINET SHLD SERVICE PORT TD RD +24VDC CLASS ma EXPANSION PORT DOOR AUTO/OFF/ON OUTPUT AUTO/OFF/ON OUTPUT 3 OVERRIDE 1.45 (37) Figure 3 shows the dimensions of the ACX 700 with an EMX 190. When you attach modules, they must be enclosed in the same UL listed enclosure as the controller. For additional modules, you require a larger cabinet. You can find the exact dimensions of each module in the installation instructions included with that module. 12 ACX 700 Installation Guide

23 Figure 3. Dimensions of ACX 700 on Backplate with EMX 190s, in inches (mm) R.117 (3) (318) (298).45 (11) R.195 (5) GND NEU HOT +12VDC -INPUT IN1 RET1 IN2 RET2 IN3 RET3 IN4 RET4 IN5 RET5 IN6 RET6 IN7 RET7 IN8 RET8 AC INPUT TAMPER USE COPPER CONDUCTORS ONLY AC INPUT VOLTAGE SEL 230V FROM 24V 115V TOFROMTOFROMTO E6 E7 E6 E E4 E3 E4 E2 E4 E5 P1 E1 P1 E1 P1 E2 PWR ON F1 3A,250V SLOW BLOW SUPERVISORY INPUTS SWITCH 9 EXT RESET TAMPER ABA SWITCH +5V LED WIEGAND I/DATA O/CLK READER 1 GND CPU + - B1 3.6V 1.8AHr LITHIUM ACX700 C1 C2 C3 R1 KEYPAD 1R2 R3 R4 RET C1 KEYPAD 2 C3 C2 R1 R2 R3 R4 RET OVERRIDE AUTO/OFF/ON DOOR 1 OUTPUT (362) (292) +5V LED I/DATA O/CLK GND + SHLD WIEGAND INFINET SERVICE PORT READER 2 ABA TD RD DOOR AUTO/OFF/ON OUTPUT +24VDC CLASS mA AUTO/OFF/ON EXPANSION PORT OUTPUT 3 OVERRIDE 1.45 (37) 6.72 (171) 4.95 (126) BOARD 1 2 EMX190 DOOR SWITCH RTN EXIT REQUEST RTN RTN CARD 0-CLK READER1/DATA INPUT LED +5V DOOR NC OUTPUT C OVERRIDE NO OFF 24VDC ON AUTO CLASS II WIEGAND ABA OVERRIDE CARD READER 6.72 (171) 4.95 (126) BOARD 1 2 EMX190 DOOR SWITCH RTN EXIT REQUEST RTN RTN CARD 0-CLK READER1/DATA INPUT LED +5V DOOR NC OUTPUT C OVERRIDE NO OFF 24VDC ON AUTO CLASS II WIEGAND ABA OVERRIDE CARD READER 5.38 (137) 6.13 (156) ACX 700 Installation Guide 13

24 Figure 4. Cover Plate of the ACX 700 NEU AC INPUT GND HOT USE COPPER CONDUCTORS ONLY AC INPUT VOLTAGE SELECTION 24V 115V 230V FROM TO FROM TO FROM TO E6 E4 E7 E3 E6 E4 E5 E2 -- E4 -- E5 P1 E1 P1 E1 P1 E2 F1 3A,250V SLOW BLOW ACX VDC -INPUT + POWER LED IN1 RET1 IN2 RET2 IN3 RET3 IN4 RET4 IN5 RET5 IN6 RET6 IN7 RET7 IN8 RET8 EXT TAMPER TAMPER SWITCH 9 PWR ON SUPERVISORY INPUTS ABA RESET + - B1 3.6V 1.8AHr LITHIUM KEYPAD 1 KEYPAD 2 OVERRIDE C1 C2 C3 R1 R2 R3 R4 RET C1 C2 C3 R1 R2 R3 R4 RET SWITCH +5V LED I/DATA O/CLK GND WIEGAND READER 1 CPU AUTO/OFF/ON DOOR 1 OUTPUT +5V LED I/DATA O/CLK GND + SHLD READER 2 ABA WIEGAND INFINET TD RD +24VDC CLASS m A AUTO/OFF/ON AUTO/OFF/ON DOOR 2 OUTPUT OUTPUT 3 SERVICE PORT EXPANSION PORT OVERRIDE 14 ACX 700 Installation Guide

25 Figure 4 shows the location of various parts inside the ACX 700, labeled on the cover plate. Note the parts of the controller labeled here. You may want to refer to this figure to locate parts during the installation process. Connecting the AC Power Warning Be sure the AC power cable is not connected to an electrical power source while you are wiring the controller, or you could receive an electrical shock that is life-threatening. If you choose to use a 12 VDC UPS power supply, skip these instructions and go to the section called Connecting the UPS Power Supply. The AC power connection is in the upper left corner of the controller. You must wire the AC cable to the three screws on the far left. Caution Be sure to connect all three wires, HOT, NEUTRAL, and GROUND. Otherwise, the controller could malfunction. The three screws are labeled GND, NEU, HOT. 1. Place the ground wire under the metal plate behind the screw labeled GND. 2. Tighten the screw with a flathead screw driver. Figure 5 shows the position of the plate, where to place the wire, and how the screw fits on the plate. You can see how the screw holds the plate in place once you tighten it. ACX 700 Installation Guide 15

26 Figure 5. Metal Plate and Screw for Power Supply Wire Metal Plate Insert Wire Here 3. Place the neutral wire under the metal plate behind the screw labeled NEU. 4. Tighten the screw with a flathead screw driver. 5. Place the hot wire under the metal plate behind the screw labeled HOT. 6. Tighten the screw with a flathead screw driver. Selecting the AC Input Voltage The voltage is set to 115 V when shipped. To change the voltage, you must reset the jumpers to the right of the AC power cord connection. Table 2 shows jumper settings for the three voltages. Table 2. Connecting Jumpers for AC Input Voltages 24V Jumpers 115V Jumpers 230V Jumpers From To From To From To E6 E7 E6 E5 E4 E3 E4 E2 E4 E5 P1 E1 P1 E1 P1 E2 To change the voltage from 115 V to 24 V, proceed as follows: 1. Disconnect the jumper end from E5 and move it to E7 so it jumpers E6 to E7. 16 ACX 700 Installation Guide

27 2. Disconnect the jumper end from E2 and move it to E3 so it jumpers E4 to E3. 3. Leave the other jumper as it is. To change the voltage from 115 V to 230 V, proceed as follows: 1. Disconnect the jumper from E6 to E5 and remove it. 2. Disconnect the jumper from E5 and connect it to E2, so it jumpers E4 to E2. 3. Disconnect the jumper from E1 and connect it to E2, so it jumpers P1 to E2. Connecting the UPS Power Supply If you choose to connect the controller to a UPS power supply, you may not also connect it to AC power. Note Be sure to size the power supply to provide 1.6 A for each ACX 700 controller. If the supply also provides power to motion sensors, card readers, or other auxiliary devices, be sure to size the power supply accordingly. Wire the UPS power supply to the terminal block connector below the AC input labeled +12VDC INPUT. The connector is immediately to the left of the power indicator light labeled PWR ON. You wire the power supply as follows: 1. Slip the hot wire under the screw labeled + and tighten the screw down on the wire. 2. Slip the ground wire under the screw labeled and tighten the screw down on the wire. Once the power supply is connected, the PWR ON light should light up. ACX 700 Installation Guide 17

28 Connecting the Power Indicating LED Caution If you purchased the ACX 700 enclosed in the Andover Controls cabinet, skip this section and proceed with the next section, Wiring the Infinet to the ACX 700. If you purchased the ACX 700 without the cabinet (open class), included with it is an LED that you can wire to the printed circuit board and mount on the front of the UL listed enclosure. This LED lights up to indicate that the unit is receiving power. Mounting the LED If you had the cabinet provided by Andover Controls, you would see the 1 LED on the front door of the cabinet, approximately in. (6 mm) to the left of and below the logo/product name. Figure 6 shows where the LED would be located. You should position the LED in an approximately equivalent location. 18 ACX 700 Installation Guide

29 Figure 6. Location of Power Indicating LED on Front Door of Cabinet Provided Location of Power Indicating LED on Front Door of Cabinet Provided To mount the LED on the front of the UL enclosure for the open class controller, proceed as follows: 1. If you have an open class controller, drill a in. (9.5 mm) hole in the front of the enclosure for it. Drill the hole approximately in front of where the controller is labeled EXTERNAL LED on the cover plate. 2. Find the LED included with the controller. It should have two wires on the back end. Figure 7 shows the LED with the three nuts and one washer on it. 3 ACX 700 Installation Guide 19

30 Figure 7. Power Indicating LED and Its Parts LED Red Wire (+) Black Wire ( ) 3/16-in. (4.7 mm) Front Nut 1/16-in. (1.5 mm) Front Nut Washer Hexagonal Nut 3. Remove the two front nuts from the LED assembly. 4. Insert the LED through the drilled hole. Figure 8 shows how to insert the LED through the drilled hole. Figure 8. Inserting the External LED through Drilled Hole Outside Cabinet or Enclosure Cabinet Door Inside Cabinet or Enclosure 1 5. Screw the in. (1.5 mm) front nut approximately in. (6 mm) onto the threaded area Screw the in. (4.7 mm) front nut on as far as you can Unscrew the in. (1.5 mm) nut until it is tight against the in. (4.7 mm) frontmost nut and secures it. 8. Tighten the hexagonal nut from the rear until it is tight against the inside of the enclosure ACX 700 Installation Guide

31 Now, you are ready to wire the LED to the controller. Wiring the Power Indicating LED You wire the LED to the screws labeled +/ POWER LED as follows: 1. Slip the red wire for the sensor under the screw labeled + next to POWER LED and tighten the screw down on it. 2. Slip the black wire under the screw labeled next to POWER LED and tighten the screw down on it. Wiring the Infinet to the ACX 700 Note You must use shielded cables for Infinet to ensure compliance with the Class A FCC limits and to ensure reliable communications. Figure 9 illustrates how to wire the Infinet cable to the removable terminal block connector in the lower left corner of the ACX 700. Figure 9. Infinet Cable Wiring Infinet Connection + SHLD 1. Trim back the shield over the wires. 2. Take the first wire for the incoming Infinet and the first wire for the outgoing Infinet and slip both in the hole beneath the screw labeled with a plus sign. 3. Tighten the screw down on them until the screw holds the wires in place. ACX 700 Installation Guide 21

32 4. Slip the second (usually black) wire from each Infinet cable under the screw labeled with a minus sign and tighten the screw down on them. 5. Slip the shields from the incoming and outgoing Infinet cables under the screw labeled SHLD and tighten the screw down on them. Wiring the Infinet to the Infinity CX 9000 or 9200 You connect the last piece of Infinet cabling to the Infinity CX 9000 or 9200, as described below (refer to the illustration): 1. Open the front of the Infinity CX 9000 controller cabinet. Notice that to the left are three ports labeled COMM1, COMM2, and COMM3. Two RS-485 ports, one above the three comm ports and one below, are in the same area. Notice that the end of the Infinet cable has two wires and a shield. You wire them to the terminal block connector on the RS-485 port. Figure 10 illustrates how to wire the Infinet cable to the Infinity CX 9000 or Figure 10. Attaching the Infinet Cable to Infinity CX 9000 or IN IN SHLD +OUT OUT 2. Run the cable through the knockout on the left side of the controller. 3. Select the port to wire the cable to on a 9000, either the RS-485 port just above the three RS-232 ports (COMM2) or the RS-485 port just below the three RS-232 ports (COMM1). Once you use either of 22 ACX 700 Installation Guide

33 these ports for COMM1 or COMM2, the RS-232 port for COMM1 or COMM2 is disabled. On a 9200, you can also select COMM4. 4. Trim back the shield over the wires. 5. Slip the first wire through the hole under the screw labeled +IN and jumper it to the screw labeled +OUT. 6. Tighten both screws to hold the wire there. 7. Slip the ground wire through the hole under the screw labeled IN and jumper it to the screw labeled OUT. 8. Tighten both screws to hold the wire there. 9. Slip the shield in under the middle screw labeled SHLD and tighten the screw to hold it there. ACX 700 Installation Guide 23

34 Wiring Inputs Caution Do not remotely ground any part of the sensor wiring. Remote grounds connected to the ACX 700 return terminal could make the controller operate incorrectly or damage the equipment. The signal return is not true earth ground. It is an electronic reference point necessary to interpret the sensor properly. Do not externally ground sensor or switch terminals that return to the ACX 700. Caution Card readers require shielded wiring. Although two-wire inputs usually function properly with unshielded sensor wire, you may need shielded wire if you run the wire as follows: In the same conduit with other noise-generating conductors such as 60 Hz AC power. In long runs close to large power-consuming or power-generating equipment that can produce 60 Hz noise. We recommend you run input wiring in a conduit separate from AC power or output wiring and avoid long wiring runs. The supervisory inputs are on the upper left side of the ACX 700, just below the 12VDC UPS power connector. Input wires should enter from the left side. Notice that the inputs are labeled IN1, RET1, IN2, RET2, IN3, RET3, IN4, RET4, and so on, for up to eight inputs. The first return terminal goes to the first input, the second to the next input, and so on. 24 ACX 700 Installation Guide

35 Caution Follow the rules below when wiring inputs and outputs: Never lay wires across the surface of the printed circuit board. You should bring input wires in from the left and output wires in from the right. Bundle excess wires toward the back of the cabinet to avoid any contact with circuit boards. Wires should never be within 1 in. (25 mm) of any component on the printed circuit board. Keep cabinet free of foreign materials (extra power supplies, relays, and so on). Be careful when stripping wire not to drop small pieces of wire inside the cabinet. If you violate any of these rules, the controller could malfunction. ACX 700 Installation Guide 25

36 Supervisory Input Circuits All 700/780 controller series inputs are supervisory inputs. The following drawings depict the six types of supervisory inputs that exist three normally closed and three normally open types. After the drawings, there is an explanation of which types are recommended for access control installations. Figure 11 shows the three types of normally closed supervisory inputs. Figure 11. Normally Closed Supervisory Inputs NC Series Door Closed SW Closed 10K Door Open SW Open Infinite SW Shorted Zero K Wire Cut Infinite Door Open and Wire Cut conditions both result in an infinite reading. If the door was sensed open without a valid card swipe, a Door Violation should be triggered. NC Parallel Door Closed SW Closed Zero K Door Open SW Open 10K SW Shorted Zero K Wire Cut Infinite Not the best choice, the switch could be shorted and the door forced open, and the system would still think the door was closed. NC Series and Parallel Door Closed SW Closed 5K Door Open SW Open 10K SW Shorted Zero K Wire Cut Infinite This configuration is the best choice; the parallel and series resistors provide a redundant security feature. 26 ACX 700 Installation Guide

37 Figure 12 shows the three types of normally open supervisory inputs. Figure 12. Normally Open Supervisory Inputs NO Series Door Closed SW Open Infinite Door Open SW Closed 10K SW Shorted Zero K Wire Cut Infinite This configuration is not the best choice. If the wire is cut and the door forced open, and the system senses that the door is still closed. NO Parallel Door Closed SW Open 10K Door Open SW Closed Zero K SW Shorted Zero K Wire Cut Infinite This configuration is defeated by shorting the switch. The systems senses this condition as a normal door open situation. However if the wire is cut, that is a unique resistance that can easily be identified as a tampering situation. NO Series and Parallel Door Closed SW Open 10K Door Open SW Closed 5K SW Shorted Zero K Wire Cut Infinite This configuration provides the most security. There are four unique resistance values associated with the four possible conditions. We recommend NO Parallel and NO Series and Parallel types for access control installations. The next sections explain how to wire these types of inputs for door switches and motion detectors. ACX 700 Installation Guide 27

38 Wiring Door Switches You may wire up to two of the eight supervisory inputs to door switches. The maximum length wire you may use is 500 ft of #18 gauge wire (152 m of 1.0 mm 2 ) or 200 ft of #22 gauge wire (60 m of 0.35 mm 2 ). You wire the door switch as follows (switches may be either normally open or normally closed): 1. Slip the appropriate wire under the IN screw and tighten the screw down on it. Figure 13 shows the wiring diagram for the input if the door switch is an ordinary switch. This switch can detect either the switch position, or tampering if the switch has an open fault. If the switch is shorted, it appears closed. Figure 13. Wiring Ordinary Switch to DoorSwitch Input RET 10 KΩ IN1 28 ACX 700 Installation Guide

39 Figure 14 shows the wiring diagram for the input if the door switch has a built-in series resistor. This switch can detect either the switch position, or tampering where the switch is shorted or grounded. We recommend this switch for situations requiring the greatest security. Figure 14. Wiring Switch with Built-in Resistor to DoorSwitch Input RET 10 KΩ IN1 Each switch requires a single parallel resistor to provide extra security should an intruder attempt to break in through the door by closing the contact. 2. Slip the ground wire under the RET screw that corresponds to the IN number and tighten the screw down on it. 3. Be sure you wire the 10 KΩ resistor in parallel as shown in each diagram. Figure 15 shows the how the door switch works if it is an ordinary switch (normally open). The switch remains open while the door is in a normal state (closed or not tampered with). If the switch detects the door is open or has been tampered with, it appears closed. ACX 700 Installation Guide 29

40 Figure 15. Functioning of DoorSwitch Input Wired to Supervisory Input Access Controller Normally Open DoorSwitch 10 KΩ Door Closed (Normal) Normally Open DoorSwitch Access Controller 10 KΩ Detects Door Open Wiring Motion Sensors/Exit Push Buttons You may wire up to two of the first four supervisory inputs to motion sensors or exit buttons. You wire them the same way you wire Door- Switch inputs, only the motion sensor requires an external power supply of 12 ± 2 VDC or 24 ± 2 VDC (UL listed under APHV). The maximum length wire you may use is 500 ft of #18 gauge wire (152 m of 1.0 mm 2 ) or 200 ft of #22 gauge wire (60 m of 0.35 mm 2 ). Be sure that when you wire the motion detector, it is correctly set up, as illustrated in the next figure. 30 ACX 700 Installation Guide

41 Figure 16 shows the how the motion detector works if it is an ordinary Passive Infrared (PIR) Motion Detector. The switch (normally open) remains open while it detects no motion or tampering If the switch detects motion, it appears closed. Figure 16. Functioning of Passive Infrared (PIR) Motion Detector Switch Wired to Supervisory Input Access Controller Normally Open PIR Motion Detector 10 KΩ No Motion Detected Normally Open PIR Motion Detector Access Controller 10 KΩ Motion Detected!!! ACX 700 Installation Guide 31

42 Wiring Other Two-Wire Inputs Follow these steps to wire two-wire inputs: 1. Slip the first wire for the sensor under the screw labeled IN5 and tighten the screw down on it. 2. Slip the ground wire under the RET5 screw and tighten the screw down on them. 3. Repeat the steps for each pair of inputs. Figure 17 shows a counter wired to an input point. Figure 17. Wiring Diagram for Counter or Digital Input 1 (input point 1) Wiring Card Reader Inputs RET (return) Be sure you wire all card readers with shielded wiring. The maximum length of wire you may use depends on the card reader brand name and the type of wiring/cable you use. Refer to the earlier sections in this manual. In the case of Proximity card readers, you may connect the required 12 ±2 VDC power supply at the ACX 700 or at the card reader. 32 ACX 700 Installation Guide

43 Wiring Wiegand Card Reader (Sensor Engineering) Wire the Sensor Engineering Wiegand card reader to the READER 1 and READER 2 inputs on the lower left side of the ACX 700 as follows: 1. Look at the wire connection on your Wiegand card reader. Notice that you have five connection points: + 5VDC DATA1 DATA0 LED GND 2. Wire the first end of each wire to the appropriate connection point on the card reader. Figure 18 shows where to connect the various wires on the card reader and the ACX 700. Figure 18. Connections Between Card Reader and Controller Card Reader +5VDC DATA1 DATA0 LED GND ACX 700 Controller +5V LED 1/DATA 0/CLK GND 3. Slip the other end of the +5VDC wire under the +5 V screw on the controller and tighten the screw down on it. 4. Slip the other end of the DATA1 wire under the 1/DATA screw on the controller and tighten the screw down on it. 5. Slip the other end of the DATA0 wire under the 0/CLK screw on the controller and tighten the screw down on it. ACX 700 Installation Guide 33

44 6. Slip the other end of the LED wire under the LED screw and tighten the screw down on it. Figure 19 illustrates where you connect the various wires. Figure 19. Wiring Wiegand Card Reader (Sensor Engineering) to Controller Card Reader ACX VDC DATA1 DATA0 LED GND Shield +5V LED 1/DATA 0/CLK GND 7. Slip the GND wire and the shield under the GND screw and tighten the screw down on it. 8. Tie back the shield at the card reader end and any wires you do not use. 9. Set the switch on the ACX 700 cover plate (to the right of the wiring) to WIEGAND. 34 ACX 700 Installation Guide

45 Wiring Proximity PR-10/PR-12 Card Reader The Proximity card reader requires a 12 ±2 VDC power supply. You wire the card reader inputs as follows: 1. Look at the wire connections on your Wiegand card reader: 0 1 LED +12 GND 2. Wire the first end of five wires to the appropriate connection point. Figure 20 shows where to connect the various wires on the card reader and the ACX 700. Figure 20. Connections Between Card Reader and Controller Card Reader ACX 700 Controller 0 1 LED +12* GND * see next illustration +5V LED 1/DATA 0/CLK GND* 3. Tie back the shield at the card reader end. 4. Slip the other end of the 0 wire under the 0/CLK screw on the controller and tighten the screw down on it. 5. Slip the other end of the 1 wire under the 1/DATA screw on the controller and tighten the screw down on it. 6. If the controller has an LED, slip the other end of the LED wire under the LED screw on the controller and tighten the screw down on it. ACX 700 Installation Guide 35

46 Figure 21 illustrates where you connect the various wires, including the shield and the 12 ±2 V power supply. Figure 21. Wiring Proximity Wiegand Card Reader to Controller, with 12 VDC Power Supply 0 1 LED +12 GND +12 wire from reader SHIELD extension wire +5V LED 1/DATA 0/CLK GND Card Reader ACX GND +12 +/-2 VDC Power Supply (Two wires and shield go to GND) 7. Wire the other end of the +12 wire to the positive terminal of a 12 ±2 VDC power supply. 8. Attach an extension wire to the GND terminal of the 12 ±2 VDC power supply. 9. Take the other end of the extension wire from the 12V power supply, the other end of the cable GND wire, and the end of the shield. Slip all of them under the GND screw on the module; tighten the screw down on them. 10. Set the switch on the ACX 700 cover plate (to the right of the wiring) to WIEGAND. 36 ACX 700 Installation Guide

47 Caution The power supply for the Proximity card reader must have the following specifications: Be nonswitching and fully regulated. Ripple must be less than 2 mv. Size the output for the amperage plus 25%. The PR-10 or PR-12 draws 150 ma, the PR-20 or PR-22 draws 250 ma. We recommend you use a UL listed power supply. Wiring the Dorado ABA Card Reader You wire the Dorado ABA card reader inputs as follows: 1. Look at the wire connections on your ABA card reader: +5 LED DATA CLK COMMON 2. Wire the first end of each wire to the appropriate connection point on the card reader. Figure 22 shows where to connect the various wires on the card reader and the ACX 700. Figure 22. Connections Between Card Reader and Controller Card Reader ACX 700 Controller +5V LED DATA CLK COMMON +5V LED 1/DATA 0/CLK GND ACX 700 Installation Guide 37

48 3. Slip the other end of the +5 wire under the +5 V screw on the controller and tighten the screw down on it. 4. Slip the other end of the LED wire under the LED screw and tighten the screw down on it. 5. Slip the other end of the DATA wire under the 1/DATA screw on the controller and tighten the screw down on it. 6. Slip the other end of the CLK wire under the 0/CLK screw on the controller and tighten the screw down on it. 7. Slip the other end of the COMMON wire under the GND screw and tighten the screw down on it. Figure 23 illustrates where you connect the various wires. Figure 23. Wiring Dorado ABA Card Reader to Controller +5V LED DATA CLK COMMON +5V LED 1/DATA 0/CLK GND Card Reader ACX Tie back the shield as well as any wires you do not use. 9. Set the switch on the ACX 700 cover plate (to the right of the wiring) to ABA. If you would like to connect a different card reader, contact your Andover Controls representative. For information on how to assign and program the inputs and outputs, see the Infinity CX Programmer s Guide. 38 ACX 700 Installation Guide

49 Wiring Keypad Inputs You wire the keypads to the keypad inputs on the right side of the controller, near the middle. The maximum length of wire to the keypad is 200 ft of #22 gauge wire (152 m of 1.0 mm 2 ) and 500 ft of #18 gauge wire (60 m of 0.35 mm 2 ). Wire the keypad inputs to the input terminals marked C1, C2, C3, R1, R2, R3, R4 and RET as follows: 1. Slip the wire marked COL1 on the keypad under the screw marked C1 and tighten the screw down on it. 2. Slip the wire marked COL2 on the keypad under the screw marked C2 and tighten the screw down on it. 3. Repeat the previous step for COL3, connecting them to C3. 4. Slip the wire marked ROW1 on the keypad under the screw marked R1 and tighten the screw down on it. 5. Slip the wire marked ROW2 on the keypad under the screw marked R2 and tighten the screw down on it. 6. Repeat the previous step for ROW3 and ROW4, connecting them to R3 and R4. 7. Slip the shield under the screw marked RET and tighten the screw down on it. 8. Repeat the entire process for the second keypad. The remaining two wires for the Essex Keypad are connected as follows: 1. Connect the wire labeled 5VDC POWER (red) to the appropriate +5V Reader terminal. 2. Connect the wire labeled LED (white) to the appropriate LED Reader terminal. ACX 700 Installation Guide 39

50 Wiring Outputs The outputs are on the lower right side of the ACX 700, labeled DOOR1, DOOR2, and AUX. All output wires should enter from the right. Wiring Door Outputs Wire the door and auxiliary outputs as follows: You wire the door outputs like any other Form C output, as follows: 1. Slip the appropriate wire under the NC screw and tighten the screw down on it. 2. Slip the appropriate wire under the C screw and tighten the screw down on it. 3. Slip the appropriate wire under the NO screw and tighten the screw down on it. 4. We recommend you install a metal oxide varistor (Andover part # , purchased separately) across the door strike or lock being switched. 40 ACX 700 Installation Guide

51 Figure 24 shows the schematic for wiring a DOOR or AUX output if the circuit is normally open. Figure 24. Wiring Diagram for DOOR and AUX Form C Outputs if Normally Open NC Oxide Metal Varistor (Andover # ) C NO C Power Supply (UL listed power supply (APHV) for UL listed systems) + 12/24V Door Strike (UL listed burglaryresistant electric locking mechanism (CVXY) for UL listed systems) This configuration shows a normally deenergized lock (when secured) in a fail secure mode. Always be sure to use panic hardware that allows emergency exit from the secured area. ACX 700 Installation Guide 41

52 Figure 25 shows the schematic for wiring a DOOR or AUX output if the circuit is normally closed. Figure 25. Wiring Diagram for DOOR and AUX Form C Outputs if Normally Closed NC Oxide Metal Varistor (Andover # ) C NO 12/24V Power Supply (UL listed power supply (APHV) for UL listed systems) C Electromagnetic Door Lock (UL listed burglaryresistant electric locking mechanism (CVXY) for UL listed systems) This configuration shows a normally deenergized lock (when secured) in a fail secure mode. If power loss occurs, the lock circuit opens. Connecting Modules to the Expansion Port The expansion port at the bottom center of the controller board allows you to connect modules to expand the capabilities of the controller. For details on installing the EMX 190, see the EMX 190 Installation Guide provided with the unit. 42 ACX 700 Installation Guide

53 Caution If you are wiring an ACX 700 rather than an ACX 710, disregard the Modules Configuration Guide included with the unit and follow the guidelines that follow. You can install multiple expansion modules, along with the EMX 190s, on the ACX 700, as long as you comply with the following: Never attach more than two modules of the same model to the controller. Do not exceed the maximum total number of inputs or outputs allowed on the controller. The maximum number of inputs/outputs allowed on the ACX 700 is as follows: Outputs Maximum Base Outputs (already on controller) 3 Maximum Expansion Module Outputs 4 Maximum Total Outputs 7 Inputs Maximum Base Supervisory Inputs (already on controller) 8 Maximum Expansion Module Inputs 21 Maximum Total Inputs 29 If the modules, however, consume a total greater than 166 ma, you must add an external power supply (more later). ACX 700 Installation Guide 43

54 Caution Do not attach an output module, an input module, then another output module, as this later causes confusion when assigning input and output numbers. Attach Modules in Order You should first attach all output modules, then all input modules. Expansion Outputs Allowed Of the output modules available, you can have up to 4 expansion outputs on an ACX 700 controller. Expansion Inputs Allowed Before you add any input modules to the ACX 700, the first 4 inputs you define are the supervisory inputs on the EMX 190s. Of the input modules you can attach, you can always have a maximum of two EMX 160s and one EMX 170s for 17 more expansion inputs; the first 4 plus the 17 is a total of 21 expansion inputs. EMX 190 Modules EMX 190s must always be the first two expansion output modules on the chain. Other Output Modules After the EMX 190s, you can have one more and only one output module with up to two outputs and it can be any of the following: EMX 150 EMX 151 EMX 155 EMX 140 If you attach an EMX 141 or 143, you must count the one output as two when numbering the outputs. 44 ACX 700 Installation Guide

55 First Input Modules EMX 160s (or other digital/counter input modules with up to 16 inputs between them) must always be the first two expansion input modules on the chain. Place EMX 170 at End of Chain If you have an EMX 170 or expect to add one in the future, the EMX 170 must always be the last module on the entire chain. Setting Board Switches on Modules You must always set the first module of a particular model number to Board 1. So, we strongly advise that you attach the modules of the same model number one immediately after the other. You must set the first output module on the chain to Board 1, the second to Board 2, the third to Board 1, the fourth to Board 2, and so on no matter which model number modules. When you start the input modules, start at again Board 1 and continue to alternate from 1 to 2. Wiring Power Supply for Modules After you have installed the modules, if you require an external power supply, refer to the Modules Configuration Guide for details regarding how much external power each module you attach requires. You must wire the power supply to ensure that the modules receive power at the same time that the controller does. ACX 700 Installation Guide 45

CMX 240 Series Controller Installation Guide

CMX 240 Series Controller Installation Guide TOC CMX 240 Series Controller Installation Guide Andover Controls Corporation i Version D Reproduction or distribution forbidden. Copyright 1997 by Andover Controls. Subject to change without notice. Order

More information

TOC. CMX 220 Installation Guide. Andover Controls Corporation. Technical Manuals Online! -

TOC. CMX 220 Installation Guide. Andover Controls Corporation. Technical Manuals Online! - TOC CMX 220 Installation Guide Andover Controls Corporation i Version D Reproduction or distribution forbidden. Copyright 1997 by Andover Controls. Subject to change without notice. Order No. 30-3001-203

More information

TCX 865. TCX 865 VAV Controller Family Installation Guide. Technical Manuals Online! - Controlling Tomorrow s World

TCX 865. TCX 865 VAV Controller Family Installation Guide. Technical Manuals Online! -   Controlling Tomorrow s World Controlling Tomorrow s World TCX 865 TCX 865 VAV Controller Family Installation Guide 30-3001-497 Version D Version D Reproduction or distribution forbidden. Copyright 1997 by Andover Controls. Subject

More information

Quick Start Installation Guide

Quick Start Installation Guide RM-iCLASS Series Quick Start Installation Guide Version C0 Document Part Number UM-208 June 2009 OVERVIEW The RM-iClass Quick Start Installation Guide provides a summary of installation and connection

More information

Infosystem Remote Touchscreen Installation Instructions

Infosystem Remote Touchscreen Installation Instructions Infosystem Remote Touchscreen Installation Instructions DOC. #569102100 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements

More information

using optional EMX 190 expansion modules), and makes access decisions based on its own distributed

using optional EMX 190 expansion modules), and makes access decisions based on its own distributed Infinity ACX 700 Access Control Unit The Infinity ACX 700 is a programmable, stand-alone access controller that is a basic building block of the Infinity Security Management System. Each ACX 700 controls

More information

NSD/M1 Installation Instructions

NSD/M1 Installation Instructions NSD/M1 Installation Instructions DOC. #560502200 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements set forth in UL

More information

Rack Input Module Installation Instructions

Rack Input Module Installation Instructions Rack Input Module Installation Instructions DOC. #560105000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements set

More information

NCH-1000 (Multiple Breaker Types) Installation Instructions

NCH-1000 (Multiple Breaker Types) Installation Instructions 20M1 12345678 NCH-1000 (Multiple Breaker Types) Installation Instructions DOC. #560502100 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance

More information

QS7800A Network Interface ControlBus Module for 7800 SERIES Relay Modules

QS7800A Network Interface ControlBus Module for 7800 SERIES Relay Modules QS7800A Network Interface ControlBus Module for 7800 SERIES Relay Modules APPLICATION PRODUCT DATA The QS7800A Network Interface ControlBus Module allows remote monitoring and diagnostics of the 7800 SERIES

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS READ THIS MANUAL CAREFULLY! FAILURE TO INSTALL THIS EQUIPMENT PER THESE INSTRUCTIONS WILL VOID THE WARRANTY. AM16904-1 Rev. C pg. 1 of 12 SPECIAL NOTICES The following notices

More information

RS-232/RS-422 Optical Isolator

RS-232/RS-422 Optical Isolator MAY 1998 IC457A-F IC457A-M RS-232/RS-422 Optical Isolator CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours

More information

Andover ContinuumTM Infinet II

Andover ContinuumTM Infinet II Andover ContinuumTM Infinet II The i80 Series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. Features 0 Choose the i80 model with the

More information

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents. User Guide CPSMP-205 110 240 VAC Power Supply Module: PointSystem CPSMC1800-200 Accessory CPSMC1900-100 Accessory Contents Contents...1 Description...1 Cautions and Warnings...2 Definitions...2 Power supply

More information

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis The Transition Networks CPSMC0200-2x0 series dual-slot PointSystem chassis is designed for installation of one or two selectable Transition Networks

More information

Q WIEGAND EXPANSION MODULE

Q WIEGAND EXPANSION MODULE Q WIEGAND EXPANSION MODULE INSTALLATION MANUAL To prevent possible SERIOUS INJURY or DEATH: READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS. The user is strongly recommended to conduct a product

More information

1.0 Description. 2.0 Unpacking. 3.0 Installation

1.0 Description. 2.0 Unpacking. 3.0 Installation ES-H, ES-HA Series Precision Balance Thank you for purchasing the Model ES-H and ES-HA precision balance. Please read all operating instructions carefully before using and note the following items to ensure

More information

4100/4120-Series Class A / Class B Zone Modules Installation Instructions

4100/4120-Series Class A / Class B Zone Modules Installation Instructions 4100/4120-Series Class A / Class B Zone Modules Installation Instructions Introduction This publication describes the installation procedure for the following modules. Model Description Required Back Box

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

7800 SERIES S7810B Multi-Drop Switch Module

7800 SERIES S7810B Multi-Drop Switch Module 7800 SERIES S7810B Multi-Drop Switch Module PRODUCT DATA APPLICATION The Honeywell 7800 SERIES is a microprocessor-based integrated burner control for automatically fired gas, oil or combination fuel single-burner

More information

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001 SLATE Digital I/O Module R8001D4001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform

More information

Andover ContinuumTM Infinet II

Andover ContinuumTM Infinet II Andover ContinuumTM Infinet II i2920 System Controllers The Andover Continuum Infinet II i2920 System Controller is designed to meet the needs of your most demanding control and monitoring applications

More information

Model Bulk Sampling Scale. User s Manual

Model Bulk Sampling Scale. User s Manual Model 7050 Bulk Sampling Scale User s Manual UNITED STATES This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits

More information

Installation Instructions for UL Rev A

Installation Instructions for UL Rev A NetController II Installation Instructions for UL 864 30-3001-1008 Rev A Mounting Screw Andover Continuum Power Supply Connector Third-Party Power Supply Connector I/O Bus Connector Cover Mounting Screw

More information

RS-232 HS4 JANUARY 1997 IC131C CUSTOMER SUPPORT INFORMATION

RS-232 HS4 JANUARY 1997 IC131C CUSTOMER SUPPORT INFORMATION JANUARY 199 IC131C RS-3 HS CUSTOER SUPPORT INFORATION Order toll-free in the U.S. hours, A.. onday to midnight Friday: 8-8-BBOX FREE technical support, hours a day, days a week: Call --00 or fax --0 ail

More information

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code:

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code: INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA-675-001 Revision 1.0 Date Code: 1-1-2018 Table of Contents Table of Figures... 3 SPECIFICATIONS:... 4 INSTALLATION... 5 General:... 5 Physical Installation

More information

rcc.1081 Installation Instructions

rcc.1081 Installation Instructions rcc.1081 Installation Instructions Table of Contents Introduction...1 Specifications...2 Mounting...3 Wiring...5 Wiring Method...7 BACnet Network Wiring...8 Setting BACnet Address...9 Setting the BACnet

More information

QS7800B Network Interface ControlBus Module for Multi-Dropping 7800 SERIES Relay Modules

QS7800B Network Interface ControlBus Module for Multi-Dropping 7800 SERIES Relay Modules QS7800B Network Interface ControlBus Module for Multi-Dropping 7800 SERIES Relay Modules APPLICATION PRODUCT DATA The QS7800B Network Interface ControlBus Module allows remote monitoring and diagnostics

More information

4100/4120-Series and 4010ES Relay Modules Installation Instructions

4100/4120-Series and 4010ES Relay Modules Installation Instructions 4100/4120-Series and 4010ES Relay Modules Installation Instructions Introduction This publication describes the installation procedure for the relay cards listed in the following table. Model Number Description

More information

SYSNet QS7700A Network Interface ControlBus Module for BCS7700

SYSNet QS7700A Network Interface ControlBus Module for BCS7700 SYSNet QS7700A Network Interface ControlBus Module for BCS7700 FEATURES PRODUCT DATA Up to six ControlBus Modules per Network Interface Unit. Remote programming of nonsafety BCS 7700 values via the ControlBus

More information

lighting control. Each controller switches up to 48 high voltage, 20-amp lighting circuits, using

lighting control. Each controller switches up to 48 high voltage, 20-amp lighting circuits, using Infinity LCX 890, 891, 892, 898 Lighting Controllers The Infinity LCX 890 series of Lighting Controllers provides unparalleled performance and flexibility in lighting control. Each controller switches

More information

UC-2000 Installation Manual Unicorn Computers Technology Limited

UC-2000 Installation Manual Unicorn Computers Technology Limited UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller

More information

Start Here. Features. Model DS108 Dual Speed Hub Installation Giude

Start Here. Features. Model DS108 Dual Speed Hub Installation Giude Start Here The NETGEAR Model DS108 Dual Speed Hub is a network hub that enables users to mix and match 10 and 100 megabits per second (Mbps) devices on the same network. This capability eliminates the

More information

Four Port RS-232 Serial Interface

Four Port RS-232 Serial Interface JUNE 000 IC1C IC181C Four Port RS-3 Serial Interface CUSTOER SUPPORT INFORATION Order toll-free in the U.S. hours, A.. onday to midnight Friday: 8-8-BBOX FREE technical support, hours a day, days a week:

More information

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs VDSL LAN Extender Products LMC5220A (Standalone Set, AC) LMC5221A (Standalone, AC, CO Unit) LMC5222A (Standalone, AC, CPE Unit) LMC5223A (Standalone Set, Multi-Power) LMC5224A (Standalone, Multi-Power,

More information

Monarch 9414 Printer. TC9414EM 7/99 Rev. AB 1999 Monarch Marking Systems, Inc. All rights reserved.

Monarch 9414 Printer. TC9414EM 7/99 Rev. AB 1999 Monarch Marking Systems, Inc. All rights reserved. Monarch 9414 Printer TC9414EM 7/99 Rev. AB 1999 Monarch Marking Systems, Inc. All rights reserved. Each product and program carries a respective written warranty, the only warranty on which the customer

More information

Installation Instructions RF5010 and RF5210

Installation Instructions RF5010 and RF5210 Installation Instructions RF5010 and RF5210 HES, Inc. 22630 N. 17th Ave. Phoenix, AZ 85027 800-626-7590 1 Product Description Dimensions Orientation Compatibility Access Control Systems Proximity Cards

More information

Hardware Installation. Tracer MP581 Programmable Controller CNT-SVN01C-EN

Hardware Installation. Tracer MP581 Programmable Controller CNT-SVN01C-EN Hardware Installation Tracer MP581 Programmable Controller CNT-SVN01C-EN Hardware Installation Tracer MP581 Programmable Controller CNT-SVN01C-EN November 2005 Tracer MP581 Programmable Controller Hardware

More information

Power Hub Cat. No. 83A00-1. Installation Manual WEB VERSION

Power Hub Cat. No. 83A00-1. Installation Manual WEB VERSION Power Hub Cat. No. 83A00-1 Installation Manual WARNINGS AND CAUTIONS Read and understand all instructions. Follow all warnings and instructions marked on the product. Do not use this product near water

More information

Installation Instructions for the AUTOcard-SA System

Installation Instructions for the AUTOcard-SA System Installation Instructions for the AUTOcard-SA System IMPORTANT NOTICE The AUTOcard-SA system is a very reliable and easy to use system. However, damage could occur if it is installed incorrectly. In particular,

More information

2U Congestion Alert Rack Insert for UK

2U Congestion Alert Rack Insert for UK 2U Congestion Alert Rack Insert for UK 2U Congestion Alert Rack Insert for UK The 2U congestion alert rack insert comes fully assembled, wired and ready to be installed in a rack. The rack provides communications,

More information

MR52 READER INTERFACE

MR52 READER INTERFACE IN IN2 IN3 IN4 INPUTS IN5 IN6 IN7 IN8 C www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA 9085-755, (562)986-905 FAX (562) 986-9205 MR52 READER INTERFACE Installation and Specifications: This

More information

CANADIAN D.O.C. WARNING

CANADIAN D.O.C. WARNING Each product and program carries a respective written warranty, the only warranty on which the customer can rely. Avery Dennison Corp. reserves the right to make changes in the product, the programs, and

More information

Now with Picture Memory

Now with Picture Memory Intrasonic Technology, Inc. Color Video Door Phone / Intercom Installer s Manual Model No.V304KIT-R Now with Picture Memory Please read this manual carefully before the products are installed.technical

More information

Installing the Tracer MP503 Input/Output Module Ordering number: ,

Installing the Tracer MP503 Input/Output Module Ordering number: , Installing the Tracer MP503 Input/Output Module Ordering number: 4950 0490, 4950 0590 Product overview The Tracer MP503 input/output (I/O) module is a field-installed device used to monitor inputs and

More information

Installation Instructions

Installation Instructions Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line

More information

Installation Instructions RF5010 and RF5210

Installation Instructions RF5010 and RF5210 Installation Instructions RF5010 and RF5210 HES, Inc. 2260 N. 17th Ave. Phoenix, AZ 85027 800-626-7590 1 Product Description Dimensions Orientation Compatibility Access Control Systems Proximity Cards

More information

RMB Peripheral Units Installation Guide

RMB Peripheral Units Installation Guide RMB Peripheral Units Installation Guide Part Number 65-000101 2011 by Kentrox, Inc. All rights reserved. Copyright 2011 by Kentrox, Inc. All Rights Reserved. The material discussed in this publication

More information

The Infinity TCX 865 programmable Infinet terminal controller is a unique, low-cost VAV box

The Infinity TCX 865 programmable Infinet terminal controller is a unique, low-cost VAV box Infinity TCX 865,866 VAV Controller with Built-in Actuator The Infinity TCX 865 programmable Infinet terminal controller is a unique, low-cost VAV box controller that comes equipped with a built-in damper

More information

INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B

INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM Doc. 6001051 Rev B Page 2 of 7 Doc 6001051 Rev B IMPORTANT NOTICES The Mini-Key system is a very reliable and easy to use system. However, damage could

More information

BACnet. b3810 Series Local Controllers

BACnet. b3810 Series Local Controllers BACnet b380 Series Local Controllers The Andover Continuum TM b380 series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. 0 Features Choose

More information

Cardax Prox Plus Mifare Reader

Cardax Prox Plus Mifare Reader Installation Note Cardax Prox Plus Mifare Reader CAUTION This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning

More information

Custom Controller Installation Instructions

Custom Controller Installation Instructions MODEL CUSTOM CONTROLLER HARDWARE CODE MAX ALLOWABLE AMBIENT TEMP: 70 C (158 F) THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: 1) THIS DEVICE MAY

More information

TruPortal Dual Door Interface Module Quick Reference

TruPortal Dual Door Interface Module Quick Reference TruPortal Dual Door Interface Module Quick Reference en-us Packing List Introduction The TruPortal Dual Door Interface Module (TP-ADD-2D) can support two complete door configurations, with up to two readers

More information

FlexPass. ASR Long Range Reader. Installation Guide Jeronimo Road Irvine, CA July 16, 2007 Document Number K , Rev B

FlexPass. ASR Long Range Reader. Installation Guide Jeronimo Road Irvine, CA July 16, 2007 Document Number K , Rev B 9292 Jeronimo Road Irvine, CA 92618-1905 FlexPass ASR-620++ Long Range Reader Installation Guide July 16, 2007 Document Number K02021-000, Rev B FlexPass ASR-620++ Long Range Reader K02021-000 Rev. B Contents

More information

SINGLE READER EXPANSION MODULE

SINGLE READER EXPANSION MODULE SINGLE READER EXPANSION MODULE INSTALLATION GUIDE A D C - A C X 1 TR- SINGLE READER EXPANSION MODULE The ADC-ACX1 Single Reader Expansion Module provides a solution for interfacing to a one Wiegand reader

More information

Expandable Power Systems

Expandable Power Systems Expandable Power Systems Installation Guide Models Include: Maximal11EV 12VDC @ 4A or 24VDC @ 3A. 12VDC @ 4A or 24VDC @ 3A. Maximal33EV 12VDC or 24VDC @ 6A. 12VDC or 24VDC @ 6A. Maximal37EV 24VDC @ 10A.

More information

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A Installation Guide Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit Issue: 052209 PN: 883884-11L Rev. A ii Copyright Notice 2009, Wyse Technology Inc. All rights reserved. This manual and the software

More information

BEETLE /Fusion Compact. Installation Guide

BEETLE /Fusion Compact. Installation Guide BEETLE /Fusion Compact Installation Guide The reproduction, transmission or use of this document or its contents is not permitted without express authority. Offenders will be liable for damages. All rights,

More information

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual Lantech IPES-0008-4 8 10/100TX with 4 PoE Injectors 24~48VDC Industrial Switch User Manual V1.00 Jun 2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

PXL-250 Tiger Controller

PXL-250 Tiger Controller PXL-0 Tiger Controller This quick start guide is made up of specification sheets, a DO/DON T list, basic installation drawings, first time power-on instructions, and short descriptions of key terms and

More information

PETROL (P-SERIES), TTL, INSERTION READER TECHNICAL REFERENCE MANUAL

PETROL (P-SERIES), TTL, INSERTION READER TECHNICAL REFERENCE MANUAL PETROL (P-SERIES), TTL, INSERTION READER TECHNICAL REFERENCE MANUAL Manual Part Number 99875139 Rev 8 MAY 2003 REGISTERED TO ISO 9001:2000 20725 South Annalee Avenue Carson, CA 90746 Phone: (310) 631-8602

More information

Security Solutions. Installation Manual Revision - April, 2004

Security Solutions. Installation Manual Revision - April, 2004 Security Solutions S321-DIN Controller Installation Manual 24-10046-18 Revision - April, 2004 1757 Tapo Canyon Road, Simi Valley, CA 93063 Tel (805) 522-5555 Fax (805) 582-7888 www.johnsoncontrols.com

More information

4100/ VDC Converter Installation Instructions

4100/ VDC Converter Installation Instructions 4100/4120-0156 8 VDC Converter Installation Instructions Introduction This publication describes the installation procedure for the 8 VDC Converter. Related Documentation Field Wiring Diagram for 4100

More information

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming AC-115 Compact Networked Single- Controller Hardware Installation and Programming Copyright 2013 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to REL,

More information

PC Media Converter, Switching (TP-TX/FX)

PC Media Converter, Switching (TP-TX/FX) April 2006 LH6620C LH6621C LH6622C LH6623C PC Media Converter, Switching (TP-TX/FX) Copyright 2006. Black Box Corporation. All rights reserved 1000 Park Drive * Lawrence, PA. 35055-1018 * 724-746-5500

More information

INSTRUCTION MANUAL. SGB20(D) Transient Protection System. June Copyright 2008 Campbell Scientific (Canada)Corp.

INSTRUCTION MANUAL. SGB20(D) Transient Protection System. June Copyright 2008 Campbell Scientific (Canada)Corp. INSTRUCTION MANUAL SGB20(D) Transient Protection System June 2008 Copyright 2008 Campbell Scientific (Canada)Corp. WARRANTY AND ASSISTANCE This equipment is warranted by CAMPBELL SCIENTIFIC (CANADA) CORP.

More information

Autoranging True RMS Multimeter User Manual

Autoranging True RMS Multimeter User Manual Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.

More information

InView Marquee Message Display

InView Marquee Message Display Installation Instructions InView Marquee Message Display Introduction These instructions show how to change the serial address and how to mount InView series signs with NEMA Types 4, 4X, and 12 enclosures.

More information

Installer/User Guide

Installer/User Guide Installer/User Guide Avocent Corporation 4991 Corporate Drive Huntsville, Alabama 35805-6201 USA 256-430-4000 (Fax) 256-430-4030 http://www.avocent.com FCC Notification Warning: Changes or modifications

More information

3M Wrist Strap and Ground Monitor 773. User s Guide

3M Wrist Strap and Ground Monitor 773. User s Guide 3M Wrist Strap and Ground Monitor 773 User s Guide Table of Contents Section Page Safety Information... 2 1 Description... 4 Overview... 4 Performance... 4 2 Installation... 5 Supplied Parts... 5 Wire

More information

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual User s Manual ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1 200 HP)

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide Direct Digital VAV Controllers KMD-7001/7051 - VAV Terminal Units KMD-7002/7052 - Dual Duct VAV Units KMD-7003/7053 - Fan Induction Units 907-019-01C 1 Introduction This

More information

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.

More information

2012 IDenticard Systems, Inc.

2012 IDenticard Systems, Inc. Contents 3 Table of Contents Regulatory Notices Mounting, Power and PC Requirements 9 10 Preparing... the Site 10 Using Pow er-conditioning... Devices and Backup Pow er Sources 10 Preparing Prem isys...

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief

More information

Envoi Installation and Setup Instructions

Envoi Installation and Setup Instructions Envoi Installation and Setup Instructions DOC. #569068500 F 4/18/05 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements set forth

More information

FIBER OPTIC A/B/C/D SWITCH (NON-LATCHING)

FIBER OPTIC A/B/C/D SWITCH (NON-LATCHING) JANUARY 2008 Model# SW1006A FIBER OPTIC A/B/C/D SWITCH (NON-LATCHING) CUSTOMER Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) SUPPORT FREE technical support, 24 hours a day,

More information

L1-34A February ADP-40 Analog Door Phone Hardware Installation Guide

L1-34A February ADP-40 Analog Door Phone Hardware Installation Guide 61200761L1-34A February 2006 ADP-40 Analog Door Phone Hardware Installation Guide Trademarks ADP-40 Analog Door Phone Hardware Installation Guide Trademarks Any brand names and product names included in

More information

FIBER OPTIC A/B/C/D SWITCH (LATCHING)

FIBER OPTIC A/B/C/D SWITCH (LATCHING) JANUARY 2008 Model# SW1005A FIBER OPTIC A/B/C/D SWITCH (LATCHING) CUSTOMER Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) SUPPORT FREE technical support, 24 hours a day, 7 days

More information

Zenith DS9000 Dispensing System

Zenith DS9000 Dispensing System Page Date: 04/2009 Zenith DS9000 Dispensing System Installation & Operation Manual Page 2 Table of Content Introduction... 3 Control Specification... 4 Wiring Diagram... 5 Wiring Instructions... 6 Field

More information

Intersection Preassembled Backplate DC

Intersection Preassembled Backplate DC Intersection Preassembled Backplate DC The intersection preassembled backplate arrives fully assembled, wired and ready to be installed in a traffic cabinet. The backplate provides communications, power

More information

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN 1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,

More information

PowerLogic High Density Metering System 1-Meter Enclosure

PowerLogic High Density Metering System 1-Meter Enclosure PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these

More information

PR402 v2.0 Installer Manual Rev.C

PR402 v2.0 Installer Manual Rev.C PR402 v2.0 Installer Manual Rev.C Introduction This document contents minimum information required for electrical connections, installation and initial tests of PR402 access controller. Installation The

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

1206P (CTS ME-X.21) MODEM ELIMINATOR, X.21 INSTALLATION AND OPERATIONS MANUAL. Doc #: UA Part #: 07M1206P-A

1206P (CTS ME-X.21) MODEM ELIMINATOR, X.21 INSTALLATION AND OPERATIONS MANUAL. Doc #: UA Part #: 07M1206P-A Doc #: Part #: 07M-A MODEM ELIMINATOR, X.21 (CTS ME-X.21) INSTALLATI AND OPERATIS MANUAL An ISO-9001 Certified Company Copyright 2000 Patton Electronics Co., All Rights Reserved PATT ELECTRICS CO. INSTALLATI

More information

TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual

TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual P/N MAINST-867/869 REV 07 ISS 26NOV13 Copyright Trademarks and patents Manufacturer ACMA compliance Contact information 2013 UTC Fire

More information

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Hypercable injecteur HPOE -  Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail : Industrial IEEE 802.3at Gigabit PoE Injector User Manual v.1.0 Jun-2011 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15

More information

Site Preparation CHAPTER

Site Preparation CHAPTER CHAPTER 3 Site Preparation This chapter describes the steps to take and the considerations you should keep in mind prior to installing the modules in an open rack. It also contains information that applies

More information

Specifications, Installation, and Operating Instructions

Specifications, Installation, and Operating Instructions Specifications, Installation, and Operating Instructions Model: Power Vantage AC Panel Protector CAUTION: The installation of a surge protection device () must be done by qualified electrical personnel.

More information

PGR-3200 MANUAL INSULATION MONITOR

PGR-3200 MANUAL INSULATION MONITOR Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-3200 MANUAL INSULATION MONITOR REVISION 3-E-040918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document Number: PM-1025-EN

More information

24 Input/8 Output AC Block I/O Module

24 Input/8 Output AC Block I/O Module 4 Input/8 Output AC Module Cat. No. 79-4A8 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air to

More information

T1 Fold (2KM) SEPTEMBER 1995 MT612A-ST MT612AE-ST. T1 - Fold CUSTOMER SUPPORT INFORMATION

T1 Fold (2KM) SEPTEMBER 1995 MT612A-ST MT612AE-ST. T1 - Fold CUSTOMER SUPPORT INFORMATION SEPTEMBER 1995 MT612A-ST MT612AE-ST T1 Fold (2KM) T1 - Fold PWR LINK CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support,

More information

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1.

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1. Document Number: 466-1632 Rev. B September 2000 Product Summary The ITI SuperBus 2000 2 x 20 LCD (liquid crystal display) Alphanumeric Touchpad gives you complete on-site system programming and operation

More information

Mobile UHF Reader. Quick Guide. For full user s manual, please contact your local distributor. Mobile UHF Reader Quick Guide (Rev2) P/N:

Mobile UHF Reader. Quick Guide. For full user s manual, please contact your local distributor. Mobile UHF Reader Quick Guide (Rev2) P/N: Mobile UHF Reader Quick Guide For full user s manual, please contact your local distributor. Mobile UHF Reader Quick Guide (Rev2) P/N: 8012-0064001 FCC WARNING STATEMENT This equipment has been tested

More information

Control Panels B5512/B4512. en UL Installation Instructions

Control Panels B5512/B4512. en UL Installation Instructions Control Panels B551/B451 en UL Installation Instructions Control Panels Table of Contents en 3 Table of contents 1 Introduction 4 1.1 About documentation 4 1.1.1 Related documentation 4 1. Bosch Security

More information

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator The i2865 and i2866 are unique, low-cost VAV box controllers that come equipped with a built-in actuator to streamline hardware

More information