1 SMART MUX INTERFACE (SMI) I N S T R U C T I O N M A N U A L

2 2

3 CONTENTS Page 1.0 INTRODUCTION General Description Device Compatibility Theory of Operation CONFORMITY MARKINGS DELIVERY Packaging Handling Inspection Storage OPERATION Turning on the SMI Project Handler Creating a Project Modify Project Name Selecting a Project Deleting a Project SMI Configuration ID Number Set Date/time System Backup SD Card Explorer PIN Security Reboot Calibrations Project Configuration MUX configuration DMUX configuration Tilt Array (MUMS) configuration IPTM tilt configuration Project Acquisition Visual Acquisition Save New Acquisition Append Data Acquisition Downloading Data Data file troubleshooting DATA HANDLING MAINTAINANCE SPECIFICATION SPARE PARTS RETURN OF GOODS LIMITED WARRANTY 19 3

4 1.0 INTRODUCTION This manual is intended for all users of the Geosense Smart Mux Interface (SMI). 1.1 General Description The Geosense SMI is a readout unit designed to manually acquire and store readings from sensors connected to data acquisition systems, which typically will include: Geosense Analogue Remote Smart Mux Geosense Digital Remote Smart Mux The Geosense SMI can also manually acquire readings from Geosense Digital Tilt Sensors and Tilt Arrays. The SMI has been designed to enable easy manual collection of data from Remote Smart Mux enclosures while the central G8 Data logging unit is still to be installed. 1.2 Device Compatibility The following Geosense Products are compatible and can be interrogated by the SMI. Analogue Smart Mux Digital Smart Mux (DMUX) Tilt Array (MUMS) Digital Tilt Sensors (IPTM) 1.3 Theory of Operation The Geosense SMI uses the RS485 serial communication protocol to communicate with compatible target devices. Since these devices use custom commands, devices not listed in section 1.2 will not function with the SMI. Since the RS485 protocol allows for multiple devices to be connected to a single bussed string, the SMI can communicate with multiple devices from one location, given that the guidelines for the RS485 standard are adhered to. The SMI can be connected at any of the Node locations shown in the illustration below. It is important to remember if the SMI is placed at either end (Node 1 or Node N) of the string the 120Ω resistor must be turned on. 4

5 2.0 CONFORMITY Geosense Ltd Nova House Rougham Industrial Estate Rougham, Bury St Edmunds Suffolk, IP30 9ND United Kingdom Tel: +44 (0) , Fax: +44 (0) Declaration of Conformity We Geosense Ltd at above address declare that the equipment detailed below, complies with the requirements of the following EU Directives:- Low Voltage Directive 2006/95/EC Electromagnetic Compatibility Directive 2014/30/EU Radio & Telecommunications Terminal Equipment 1999/5/EC Restriction on the use of certain Hazardous Substances (RoHS2) 2011/65/EU Equipment description: Make/Brand: Model Numbers: Readout unit Geosense SMI Compliance has been assessed with reference to the following harmonised standards: EN :2013 Electrical equipment for measurement, control and laboratory use. EMC requirements. General requirements. EN :2010 Safety requirements for electrical equipment for measurement, control, and laboratory use. General requirements A technical file for this equipment is retained at the above address. Martin Clegg Director 5

6 3.0 MARKINGS The Geosense SmartMux Interface is labelled with the following information:- Manufacturers telephone number & website address Product group: Readout Model: SMI Input supply: 220 Volts AC to 12 Volt DC or 12 Volt DC Serial number: CE & WEEE mark 6

7 4.0 DELIVERY This section should be read by all users of the Geosense SMI. 4.1 Packaging The Geosense SMI is packed for transportation to site. Packaging is suitably robust to allow normal handling by transportation companies. Inappropriate handling techniques may cause damage to the packaging and the enclosed equipment. The packaging should be carefully inspected upon delivery and any damage MUST be reported to both the transportation company and Geosense. 4.2 Handling The Geosense SMI is a precision measuring instruments. They and their associated equipment should always be handled with care during transportation and storage. Once the shipment has been inspected it is recommended that the Geosense SMI remains in its original packaging for storage or transportation. Cable should also be handled with care. Do not allow it to be damaged by sharp edges, rocks for example, and do not exert force on the cable as this my damage the internal conductors.. DO NOT DROP AS THIS MAY CAUSE DAMAGE TO INTERNAL COMPONENTS 4.3 Inspection It is important to check all the equipment in the shipment as soon as possible after taking delivery and well before installation is to be carried out. Check that all the components detailed on the documents are included in the shipment. Check that the equipment has not been physically damaged. 4.4 Storage The Geosense SMI contains electronics and whilst they are designed for outside use and mounted within a water resistant enclosure the internal circuit board can be affected by excessive moisture, dust and temperature. When not in use they should be turned off and stored in a cool, dry location. 7

8 5.0 OPERATION Before the Geosense SMI can acquire readings it must first be configured Turning on the SMI Turn on the Geosense SMI using the On/Off toggle switch. If the Geosense SMI is in standby mode press ENT on the keypad. The home screen displaying the Geosense Logo should appear on the LCD screen. Press ENT again to enter the project window where the name of the current project is displayed. Note that the SMI is shipped with a default project. If no other projects have been created Default will be displayed as the Current Project Project Handler. Home > 4. Projects Handler The projects Handler menu is used to create, delete and navigate between projects Creating a Project. Home > 4. Projects Handler > 2. Create/modify A project is used to configure the SMI for a particular device or groups of devices. When a project is created for a group of devices the user must ensure the devices are all connected together in accordance to the RS485 standard. To create a new project select Create/modify by pressing 2, this will display the projects which are currently stored. Enter a unique project number and press ENT followed by the name of the project Modify Project name. Home > 4. Projects Handler > 2. Create/modify To modify the name of a project select Create/modify by pressing 2, this will display the projects which are currently stored. Enter the number of the project which requires modifying and press ENT. Confirm a project name modification is required and enter the new name Selecting a Project. Home > 4. Projects Handler > 1. Select Project To Change projects select Select Project by pressing 1, this will display a list of the projects which are currently stored. Enter the number of the project and press ENT, the selected project will now load Deleting a Project. Home > 4. Projects Handler > 1. Delete Project To Delete a project select Delete Project by pressing 3, this will display a list of the projects which are currently stored. Enter the number of the project to be deleted and press ENT. The project will now be marked deleted. Reset the device by turning it Off and then On for the changes to take effect. 8

9 5.0 OPERATION contd SMI Configuration. Home > 1. SMI Configurations The SMI configurations menu is used to alter the main settings of the Geosense SMI for each project. It is important to remember each project created has its own unique configuration ID Number Home > 1. SMI Configurations > 1. Id number The ID number should match that of the Geosense G8 Data Logger module ID which is connected or to be eventually connected to the device. This is especially important when configuring the Geosense SMI for the Geosense SmartMux since the Mux will only respond from a device with the correct ID. WARNING: During its first communication session the Geosense Smart Mux will store the ID of the device connected to it and from that moment will only respond to that ID. For this reasons users must ensure that the correct ID configured in the Geosense SMI Project matches that of the G8 PLUS logging module used for the data acquisition system Set date/time Home > 1. SMI Configurations > 2. Set date/time This option is used to set the Date and Time of the device. This setting is universal to all projects and therefore altering the date and time in one project will alter it in another System backup Home > 1. SMI Configurations > 3. System backup This option moves all available data located in SD:\{Project Number}\DATA\IPTM SD:\{Project Number}\DATA\MUMS SD:\{Project Number}\DATA\MUX To SD:\{Project Number}\DATA\Backup The process stores files by the year and month they were created SD Card explorer Home > 1. SMI Configurations > SDcard explorer This option allows files on the SD card to be viewed. Use the UP and DOWN keys to navigate and ENT to visualise subfolders and files. Press ESC to return to the previous folder PIN security Home > 1. SMI Configurations > PIN security A Pin can be set to protect the device from being accessed by unwanted users. To set a PIN navigate to PIN Security > Set/change PIN, enter a 4 digit pin and repeat to confirm. To remove the PIN select PIN Security > Remove PIN, you will be prompted for the PIN when PIN Security is selected. 9

10 5.0 OPERATION contd SMI Configuration. Home > 1. SMI Configurations contd Reboot Home > 1. SMI Configurations > 6. Reboot This option restarts the device without using the On/Off toggle switch Calibrations Home > 1. SMI Configurations > 7. Calibrations The device is calibrated at Geosense and this option should not be used unless instructed by Geosense staff Project Configuration. Home > 2. Project Config. This menu is used to configure the devices associated with the project. A project can consist of 1 device or several devices. Where several devices form a project each of those devices must be connected together and adhere to the RS485 standard. Note* the device being configured does not need to be connected during the configuration. In this instance a device describes either a: Geosense Analogue Smart Mux Geosense Digital Smart Mux Geosense Tilt Array Geosense Digital Tilt Sensor Sensors connected to Geosense Analogue Smart Mux do not need to be considered MUX configuration Home > 2. Project config. > 1. MUX configuration > 1. View mux Gives a list of the configured Mux s. > 2. New/edit mux This option allows either a new Analogue Mux configuration or modification of an existing configuration. Follow the on screen instructions to complete the set up. Instruction mux id: 0/254 Enter the ID of the Mux being configured to begin. Instruction Copy from ID? To duplicate a configuration from an existing device press ENT and select the ID of the device to be copied. For a new configuration press ESC. Instruction Channels number: 1/16? Enter the amount of channels being used. Note 1 channel refers to 1 four wire input or 2, Two wire input. On the next screen select the input type require for the A Channel by using the UP, DOWN and ENT keys. If a 2 wire input is selected for the A Channel (e.g. Vibrating Wire) another 2 wire sensor can be selected for the B Channel. If the B Channel is not in use select Disabled. 10

11 5.0 OPERATION contd Project Configuration. Home > 2. Project Config. contd MUX configuration Home > 2. Project config. > 1. MUX configuration contd. This procedure is repeated for every Channel of the Mux. To save time the configuration from previous channels can be copied. To do this enter the channel number to copy and press ENT. To manually configure the channel simply press ENT. > 3. Delete mux This option displays a list of the currently configured devices. Use the Up and Down buttons to navigate and ENT to delete the configuration. > 4. Delete all mux This option deletes the configuration of all the Mux s DMUX configuration Home > 2. Project config. > 2. DMUX configuration > 1. View dmux Gives a list of the configured DMux s. > 2. New/edit mux This option allows either a new Digital Mux configuration or modification of an existing configuration. Follow the on screen instructions to complete the set up. Instruction Channels number: 1/16 Enter the amount of channels being used. Instruction Dev. At CHX : 1/255 Enter the ID of the Geosense connected to the channel. For Geosense Tilt Array and Tilt Sensors use the String ID set during configuration. > 3. Delete mux This option displays a list of the currently configured devices. Use the Up and Down buttons to navigate and ENT to delete the configuration. > 4. Delete all mux This option deletes the configuration of all the DMux s MUMS configuration Home > 2. Project config. > 3. MUMS configuration > 1. View mums Gives a list of the configured Tilt Array String(s). 11

12 5.0 OPERATION contd Project Configuration. Home > 2. Project Config. contd MUMS configuration Home > 2. Project config. > 3. MUMS configuration contd. > 2. New/edit mums This option allows either a new Tilt Array configuration or modification of an existing configuration. Follow the on screen instructions to complete the set up. Instruction mums id:0/255 Enter a ID for the Tilt Array string and press ENT. Following this enter the amount of Tilt links, Piezometers, Baro/Extensometers and thermistors for the string. > 3. Delete mums This option displays a list of the currently configured devices. Use the Up and Down buttons to navigate and ENT to delete the configuration. > 4. Delete all mums This option deletes the configuration of all the Mums strings IPTM tilt config Home > 2. Project config. > 4. IPTM tilt config > 1. View iptm Gives a list of the configured tilt Sensors. > 2. New/edit mux This option allows either a new tilt Sensor configuration or modification of an existing configuration. Follow the on screen instructions to complete the set up. Instruction iptm id:0/255 Enter a ID for the Tilt Sensor string and press ENT. Following this enter the amount of Tilt nodes (Number of Tilt sensors). Instruction Sensor number _X Enter the serial number of the tilt sensor. Repeat this for each of the tilt nodes. > 3. Delete iptm This option displays a list of the currently configured devices. Use the Up and Down buttons to navigate and ENT to delete the configuration. > 4. Delete all iptm This option deletes the configuration of all the iptm strings. 12

13 5.0 OPERATION contd Project Aquis. Home > 3. Project Aquis. The project Acquisition menu is used to collect data from sensors connected to Geosense SMI compatible devices. The Geosense SMI must be connected to the same devices as those configured within the SMI project Visual acquisition Home > 3. Project Aquis. > 1. Visual aquis. This option allows readings to be taken and viewed on the LCD screen. Readings taken using this option WILL NOT BE SAVED. > 1. LOCAL channels This option displays the current battery voltage and temperature of the Geosense SMI unit. > 2. MUX local acquisition This option is used to display a reading from 1 channel of a Mux. Follow the on screen instructions to obtain a reading. Instruction mux number: 0 Input the ID of the mux the sensor is connected to. Instruction Press 0 for Vbatt + T 1-X for ch: 0/X Inputting 0 will take a reading and display the battery voltage and temperature of the Mux. Inputting a channel number will take and display the reading of channel. > 3. MUMS local acquisition This option is used to display a reading from 1 node of the Tilt Array. Follow the on screen instructions to obtain a reading. Instruction mux number: 0 Input the ID of the Mums string. Instruction Link number Input the link number of the Tilt Array to take and display reading. > 4. IPTM local aquisition This option is used to display a reading from 1 tilt sensor. Follow the on screen instructions to obtain a reading. Instruction iptm number: 0 Input the ID of the string the tilt sensor is connected to. Instruction Tilt number Input the tilt number of the Tilt Sensor to take and display reading. 13

14 5.0 OPERATION contd Project Aquis. Home > 3. Project Aquis. contd Save new acquisition. Home > 3. Project Aquis. > 2. Save new aquis. This option will start a NEW acquisition and obtain a reading from all configured sensors in the project. Any existing data will be moved to the Back Up folder Append data acquisition. Home > 3. Project Aquis. > 3. Append data acq. This option will start an acquisition and obtain a reading from all configured sensors in the project all new readings will be appended to existing data Downloading Data To download data, ensure the Geosense SMI is turned off and remove the SD card. Insert the SD card into a PC using a SD card reader. The file explorer window should pop up, if not open file explorer and click on the SD card to view the files. The folders are named according to the project numbers. Navigate to SD:\{Project Number}\DATA This folder contains all of the acquired data for that project. \BACKUP \IPTM \MUMS \MUX LOC0000 This folder contains all data which has been backed up and is organised by the year and date of the backup. This folder contains Tilt Sensor readings organised by String ID. This folder contains Tilt Array readings organised by tilt Array ID. This folder contains Analogue Mux readings organised by Mux ID. This file contains the date stamp, battery and temperature data for the SMI. 14

15 5.6.1 Data file trouble shooting DATA FILE TROUBLESHOOTING Readings erratic or consistently too low DIGITAL SENSORS NAN Recorded ( No Output from sensor ) Readings erratic VIBRATING WIRE SENSORS NAN Recorded ( No Output from sensor ) Readings erratic or consistently 0.00 ANALOGUE SENSORS NAN Recorded ( No Output from sensor ) Check for loose wiring connections inside and outside the logger cabinet Check integrity of the EMI Screening Check for loose wiring connections inside and outside the logger cabinet Check that the polarity of the sensor connections is correct Check for loose wiring connections inside and outside the logger cabinet Check for loose wiring connections inside and outside the logger cabinet Check that the excitation frequency Check for loose wiring connections inside and outside the logger cabinet Check integrity of the EMI Screening Check for loose wiring connections inside and outside the logger cabinet Check that the polarity of the sensor connections is correct 15

16 6.0 Data Handling The data downloaded from the Geosense SMI are formatted as.csv files. These files can be visualised using a simple text reader or a spreadsheet application such as MS Excel. The data contained in the.csv files are delimited using semi colons, depending on the regional settings the.csv file may not open as expected. To import data into excel select the Data Tab. In Get External Data select From Text and select the.csv file to import. Select Delimited and click Next. Check the box next to Semicolon and click Finish. Finally select the cell you wish to start the import from. All files will contain 4 header lines: Line 1 > Date and Time Line 2 > SMI ID Line 3 >.csv file full path. Line 4 > Blank The Output for each of the files is as follows. File Col 1 Col 2 Col 3 Col 4 Col 5 Col 6 Col 7 Col 8 Col n-2 Col n-1 Col n LOC Time Voltage Temp IPTM Time Voltage Temp Ch 1 (A) Ch1 (B) Ch 1 (T) Repeated for each channel MUX Time Voltage Temp Ch1 (A) Ch 1(B) Repeated for each channel MUMS Data requires elaboration 7.0 MAINTENANCE The Geosense SMI is basically maintenance free device for most applications but the following should be checked periodically:- ITEM Enclosure Front panel SD card RS485 connector Charger ACTION Check for damage, water ingress Check for damage Check memory use Check presence of protective cap Check operation 16

17 8.0 SPECIFICATION ITEM Internal Power Supply External Power Supply Operating Power Consumption Power Output Direct Inputs Via SmartMux User Interface Internal clock Memory Type Sampling Intervals Data Acquisition Method Data storage Read/Write data frequency SMI 12Vdc 2400mAh Ni-Mh battery pack Battery Charger for 12V Ni-Mh 100mA 12Vdc 650mA 1 x RS485 VW, V, mv/v, 4-20mA, Pt100, NTC and RS485 up to 256 sensors 14 Button Keypad, 128 x 64 backlit LCD Display 3V lithium battery TIMEKEEPER SD card 1 minute - 10 Days Locally via SD Card > 2,000,000 in maximum configuration 1MHz Operating Temperature Range -20 C to 70 C Dimension L x W x H (mm) 330 x 300 x 145 Weight Enclosure 3315g IP SPARE PARTS In general spare parts are not available for the Geosense SMI itself but the following accessories are available:- SD card SMI charger SMI fly lead Should the SMI malfunction it will need to be returned to Geosense for inspection and possible repair 17

18 10.0 RETURN OF GOODS 10.1 Returns procedure If goods are to be returned for either service/repair or warranty, the customer should contact Geosense for a Returns Authorisation Number, request a Returned Equipment Report Form QF034 and, prior to shipment. Numbers must be clearly marked on the outside of the shipment. Complete the Returned Equipment Report Form QF034, including as much detail as possible, and enclose it with the returned goods and a copy of the form should be faxed or ed in advance to the factory Chargeable Service or Repairs Inspection & estimate It is the policy of Geosense that an estimate is provided to the customer prior to any repair being carried out. A set charge for inspecting the equipment and providing an estimate is also chargeable Warranty Claim (See Limited Warranty Conditions) This covers defects which arise as a result of a failure in design or manufacturing. It is a condition of the warranty that the Geosense SMI must be installed and used in accordance with the manufacturer s instructions and has not been subject to misuse. In order to make a warranty claim, contact Geosense and request a Returned Equipment Report Form QF034. Tick the warranty claim box and return the form with the goods as above. You will then be contacted and informed whether your warranty claim is valid Packaging and Carriage All used goods shipped to the factory must be sealed inside a clean plastic bag and packed in a suitable carton. If the original packaging is not available, Geosense should be contacted for advice. Geosense will not be responsible for damage resulting from inadequate returns packaging or contamination under any circumstances Transport & Storage All goods should be adequately packaged to prevent damage in transit or intermediate storage. 18

19 11.0 LIMITED WARRANTY The manufacturer, Geosense Ltd, warrants the Geosense SMI manufactured by it, under normal use and service, to be free from defects in material and workmanship under the following terms and conditions:- Sufficient site data has been provided to Geosense by the purchaser as regards the nature of the installation to allow Geosense to select the correct components and configuration for the Geosense SMI. The Geosense SMI shall be installed in accordance with the manufacturer s recommendations. The equipment is warranted for 1 year from the date of shipment from the manufacturer to the purchaser. The warranty is limited to replacement of part or parts which, are determined to be defective upon inspection at the factory. Shipment of defective part or parts to the factory shall be at the expense of the Purchaser. Return shipment of repaired/replaced part or parts covered by this warranty shall be at the expense of the Manufacturer. Unauthorised alteration and/or repair by anyone which, causes failure of the unit or associated components will void this LIMITED WARRANTY in its entirety. The Purchaser warrants through the purchase of the Geosense SMI equipment that he is familiar with the equipment and its proper use. In no event shall the manufacturer be liable for any injury, loss or damage, direct or consequential, special, incidental, indirect or punitive, arising out of the use of or inability to use the equipment sold to the Purchaser by the Manufacturer. The Purchaser assumes all risks and liability whatsoever in connection with the Geosense SMI equipment from the time of delivery to Purchaser. 19

20 20

DATA LOGGER GEOLOGGER G8 PLUS

DATA LOGGER GEOLOGGER G8 PLUS A D V A C E D DATA LOGGER GEOLOGGER G8 PLUS I N S T CONFIGURATION & WIRING OF PERIPHERALS R U C T I O N M A N U A L 1 CONTENTS DESCRIPTION PAGE Main components 3 G8 Module Connections 4 G8 Module Connections

More information

DATA LOGGERS GL800 & 1000

DATA LOGGERS GL800 & 1000 DATA LOGGERS GL800 & 1000 I N S T R U C T I O N M A N U A L 2 CONTENTS Page 1.0 INTRODUCTION 5 1.1 General description 5 1.2 Theory of operation 5 1.3 Main components 6 1.4 Multiplexer (Flexi-Mux) 8 1.4.1

More information

G801 Digital and Interconnection Logging Module for managing of monitoring systems. MAIN FIELDS OF APPLICATION

G801 Digital and Interconnection Logging Module for managing of monitoring systems. MAIN FIELDS OF APPLICATION re a d o u t l o g g e r u n i t G801 Digital and Interconnection Logging Module for managing of monitoring systems. MAIN FIELDS OF APPLICATION - Geotechnical engineering - Hydrology - Meteorology G801_eng_1.0.2

More information

PMCG - MANUAL PMCG ORIGINAL INSTRUCTIONS. Preservatech Europe sp z o.o. Równa 1, Bydgoszcz, Poland

PMCG - MANUAL PMCG ORIGINAL INSTRUCTIONS. Preservatech Europe sp z o.o. Równa 1, Bydgoszcz, Poland PMCG ORIGINAL INSTRUCTIONS Manufactured: Designed: Preservatech Europe sp z o.o. Równa 1, 85-846 Bydgoszcz, Poland info@preservatech.eu Preservatech Inc Toronto, Canada info@preservatech.com 1 www.preservatech.com

More information

Model 206 Operating Instructions. Setra Systems, Inc. 159 Swanson Road, Boxborough, MA

Model 206 Operating Instructions. Setra Systems, Inc. 159 Swanson Road, Boxborough, MA Model 206 Operating Instructions Setra Systems, Inc. 159 Swanson Road, Boxborough, MA 01719 800.257.3872 www.setra.com 1.0 General Information Every Model 206 has been tested and calibrated before shipment.

More information

TC100 Precision Thermocouple Calibrator

TC100 Precision Thermocouple Calibrator TC100 Precision Thermocouple Calibrator Table of Contents 1. Introduction.....................1 2. Accessories....................5 3. Set-Up Basic/Advanced...........5 4. Operating Procedure.............6

More information

Operating Instructions

Operating Instructions PRIMETEST 100 PRIMETEST 100 Bracken Hill South West Industrial Estate Peterlee Co Durham SR8 2SW ENGLAND Tel: +44(0)191 5863511 www.seaward.co.uk sales@seaward.co.uk service@seaward.co.uk Part Number

More information

EPS Power Supply

EPS Power Supply EPS - 600 Power Supply Installation and Operation Manual Version 1.0 *This instrument is intended for laboratory use only Index A. Important Notice ----------------------------------------------------------------

More information

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only. Concorde 600 Power Supply Operation Manual Cat.no. R10-1001011 *This instrument is intended for laboratory use only http://www.recenttec.com E-mail : support@recenttec.com Version 1.1 Packing List x 1

More information

RST INSTRUMENTS LTD.

RST INSTRUMENTS LTD. Carlson/RST MA-7 Readout Instruction Manual 1 RST INSTRUMENTS LTD. Carlson/RST MA-7 Readout Instruction Manual Ltd. 11545 Kingston St Maple Ridge, BC Canada V2X 0Z5 Tel: (604) 540-1100 Fax: (604) 540-1005

More information

Hand-held thermometer Model CTH7000

Hand-held thermometer Model CTH7000 Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference

More information

Automated Tuner System Power Distribution Hub

Automated Tuner System Power Distribution Hub User Guide Automated Tuner System Power Distribution Hub Model MT1020B MT1020-340 (Rev B) 12/11 User Guide Automated Tuner System Power Distribution Hub Model MT1020B 2900 Inland Empire Boulevard Ontario,

More information

Operating Instructions

Operating Instructions Bracken Hill South West Industrial Estate Peterlee Co Durham SR8 2SW ENGLAND Tel: +44(0)191 5863511 www.seaward.co.uk sales@seaward.co.uk service@seaward.co.uk Part Number 344A550 Revision 1 2006 Seaward

More information

Installation, Operation & Maintenance Instructions / Technical Document

Installation, Operation & Maintenance Instructions / Technical Document Installation, Operation & Maintenance Instructions / Technical Document Model VHL Mini Vibrating Fork Point Level Sensor for Liquids Thank you for purchasing the Model VHL Mini Vibrating Fork Point Level

More information

Micro-Ohmmeter Model 6292

Micro-Ohmmeter Model 6292 Micro-Ohmmeter Model 6292 Quick Start Guide ENGLISH www.aemc.com CHAUVIN ARNOUX GROUP Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated

More information

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies M51A Option: Isolated Analog Programming Manual Power Supplies Elgar Electronics Corporation 9250 Brown Deer Road San Diego, CA 92121-2294 1-800-73ELGAR

More information

LCI User Manual mantracourt.com

LCI User Manual mantracourt.com LCI User Manual mantracourt.com LCI Load Cell Junction Box with Fault Monitor Contents Chapter 1 Introduction to the LCI... 2 Chapter 2 Installing the LCI... 3 Chapter 3 Setting up the LCI... 4 Sequence

More information

BatteryCheck USER MANUAL BATTERY MANAGEMENT TECHNOLOGY THAT POWERS YOUR ADVENTURES.

BatteryCheck USER MANUAL BATTERY MANAGEMENT TECHNOLOGY THAT POWERS YOUR ADVENTURES. BatteryCheck USER MANUAL BM PRO - 19 Henderson Road, Knoxfield 3180, Victoria, Australia Phone +61 3 9763 0962 Fax +61 3 9763 8789 Email sales@teambmpro.com Web www.teambmpro.com BATTERY MANAGEMENT TECHNOLOGY

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 E39.0.31.6C-02 Data logger for humidity temperature as of version V1.0 Operating Manual T-Logg 160 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0 +49 (0) 9402

More information

PS8 - II. Professional Power Sequencer. User s Manual

PS8 - II. Professional Power Sequencer. User s Manual PS8 - II Professional Power Sequencer User s Manual IMPORTANT SAFETY INSTRUCTIONS READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure.

More information

Instruction and Operation Manual

Instruction and Operation Manual SEC IR PC LINK Instruction and Operation Manual Sensor Electronics Corporation 5500 Lincoln Drive Minneapolis, Minnesota 55436 USA (952) 938-9486 Fax (952) 938-9617 email sensor@minn.net or www.sensorelectronics.com

More information

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to SM-10 SM-20-A Sound Level Meters Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com SM-10 / SM-20-A Sound Level Meters English Users Manual SM10_Rev002 2009 Amprobe

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

CL600 SIMPLE LOGGER RMS CLAMP-ON MODULE E N G L I S H. User Manual

CL600 SIMPLE LOGGER RMS CLAMP-ON MODULE E N G L I S H. User Manual SIMPLE LOGGER RMS CLAMP-ON MODULE CL600 E N G L I S H User Manual Owner s Record The serial number for the Simple Logger Model CL600 is located on the back of the instrument. Please record this number

More information

User's Guide. Extech AM A AC Analog Clamp Meter

User's Guide. Extech AM A AC Analog Clamp Meter User's Guide Extech AM300 300A AC Analog Clamp Meter Introduction Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device measure AC Voltage and Current, DC Voltage, and Resistance.

More information

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1 Installation and Operation Guide 70-210043-17 V 1.1 Copyright 2008 Remote Technologies Incorporated All rights reserved. 2 DECLARATIONS 117 612 914 DECLARATION OF CONFORMITY (DOC) The Declaration of Conformity

More information

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL 1 IMPORTANT SAFETY INSTRUCTION READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure-voltage

More information

POCKET MULTIMETER Model No: MM18

POCKET MULTIMETER Model No: MM18 INSTRUCTIONS FOR: POCKET MULTIMETER Model No: MM18 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained,

More information

FES LCD Display Version 1.1

FES LCD Display Version 1.1 FES LCD Display Version 1.1 LZ design d.o.o., Brod 3D, 1370 Logatec, Slovenia tel +386 59 948 898 info@lzdesign.si www.front-electric-sustainer.com Table of Content 1. Important notices... 3 1.1 Limited

More information

HI ma Simulator

HI ma Simulator Instruction Manual HI 931002 4-20 ma Simulator http://www.hannainst.com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments Product. Please

More information

2-Way Wireless I/O Expander Installation Guide

2-Way Wireless I/O Expander Installation Guide 2-Way Wireless I/O Expander Installation Guide For more detailed information please refer to the iconnect Installer Manual provided on our website: www.electronics-line.com Table of Contents 1. Introduction...

More information

VP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display

VP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display VP Process Inc. Model: Modbus RTU LCD Display User Manual Ver: 2.0 Aug. 2017 P a g e 1 Standard Features Low Power (12-24 VDC) 2.1 x 5mm Barrel Plug, RJ45 and Terminal Block Input On-Board Local Temperature

More information

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter Operation Manual MODEL 2TX 2-wire Isolated ph/orp Transmitter 0 2TX CONTENTS INITIAL INSPECTION.....2 INTRODUCTION......2 ASSEMBLY...3 PREPARATION....4 CONNECTING THE ELECTRODE...4 CONNECTING THE TEMPERATURE

More information

OPERATION MANUAL MODEL TT-LP

OPERATION MANUAL MODEL TT-LP TURTLE TOUGH OPERATION MANUAL MODEL TT-LP 2-Wire Isolated ph/orp Transmitter turtletough.com.au CONTENT INITIAL INSPECTION 3 INTRODUCTION 3 ASSEMBLY 4 PREPARATION 5 Connection Diagram of Turtle Tough Sensors

More information

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND

More information

Digital Quick-Response Thermometer

Digital Quick-Response Thermometer H56.0.01.6C-06 Digital Quick-Response Thermometer Operating Manual GTH 1170 WEEE-Reg.-Nr. DE93889386 GHM Messtechnik GmbH Standort Greisinger Hans-Sachs-Str. 26 D-93128 Regenstauf +49 (0) 9402 / 9383-0

More information

Kramer Electronics, Ltd. USER MANUAL. Model: RC-52N. Room Controller

Kramer Electronics, Ltd. USER MANUAL. Model: RC-52N. Room Controller Kramer Electronics, Ltd. USER MANUAL Model: RC-52N Room Controller Contents Contents 1 Introduction 1 2 Getting Started 1 3 Overview 2 4 Your RC-52N 3 4.1 The RC-52N Front Panel 3 4.2 The RC-52N Rear Panel

More information

I/O SIGNAL CONDITIONER

I/O SIGNAL CONDITIONER Technical Data Sheet No. TD9809M Rev. F Date of Issue: December 9, 2009 OPERATING MANUAL I/O SIGNAL CONDITIONER CAUTION: THIS PRODUCT DOES NOT PROVIDE GALVANIC ISOLATION. DO NOT ATTEMPT USE OF THIS PRODUCT

More information

Model M140 Mini Solar Power Meter

Model M140 Mini Solar Power Meter Model M140 Mini Solar Power Meter 2 Table of Contents 1 INTRODUCTION... 3 1.1 The M140 Features:... 3 1.2 The M140 Applications:... 3 2 SAFETY SUMMARY... 4 3 COMPLIANCE STATEMENTS... 5 4 PRODUCT CONTENTS

More information

AE14-503J SERIES PRODUCTION DISPLAY SYSTEM

AE14-503J SERIES PRODUCTION DISPLAY SYSTEM FN:503JMAN2.DOC AE14-503J SERIES PRODUCTION DISPLAY SYSTEM DESCRIPTION The AE14-503J Series Production Display System is a stand-alone production pacing (Goal) and monitoring (Actual) display. It includes

More information

Kramer Electronics, Ltd. USER MANUAL. Models: RC-2C, Wall Plate / RS-232 / IR Controller RC-2, Wall Plate / RS-232 Controller

Kramer Electronics, Ltd. USER MANUAL. Models: RC-2C, Wall Plate / RS-232 / IR Controller RC-2, Wall Plate / RS-232 Controller Kramer Electronics, Ltd. USER MANUAL Models: RC-2C, Wall Plate / RS-232 / IR Controller RC-2, Wall Plate / RS-232 Controller Contents Contents 1 Introduction 1 2 Getting Started 1 3 Overview 2 4 Your RC-2C/RC-2

More information

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06 PKP Prozessmesstechnik GmbH Borsigstrasse 24 D-65205 Wiesbaden-Nordenstadt Tel: 06122 / 7055-0 Fax: 06122 / 7055 50 Operating manual PSA06 Electronical pressure switch Content Page 19-34 1. Foreword 19

More information

L610 L620 L630 SIMPLE LOGGER THERMOCOUPLE MODULE E N G L I S H. User Manual

L610 L620 L630 SIMPLE LOGGER THERMOCOUPLE MODULE E N G L I S H. User Manual SIMPLE LOGGER THERMOCOUPLE MODULE L610 L620 L630 E N G L I S H User Manual Owner s Record The serial number for the Models L610, L620 and L630 is located on the side of the case. Please record this number

More information

Kramer Electronics, Ltd. USER MANUAL

Kramer Electronics, Ltd. USER MANUAL Kramer Electronics, Ltd. USER MANUAL Models: VP-200NK, 1:2 High Resolution XGA DA VP-300NK, 1:3 High Resolution XGA DA VP-400NK, 1:4 High Resolution XGA DA Contents Contents 1 Introduction 1 2 Getting

More information

Power Meter PowerMonitor 500

Power Meter PowerMonitor 500 ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION PowerMonitor 500 NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific

More information

Tracer VM Bluetooth Interface

Tracer VM Bluetooth Interface Tracer Bluetooth Interface Model number BTI-102 Operating Instructions General The Bluetooth Interface collects, transmits and saves data from Base Flowmeters installed in injection mold cooling circuits.

More information

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE User s Manual SR250HL Power Supply/ Float Charger for Lead Acid Batteries STANDARD FEATURES OPTIONAL FEATURES 3 Relay Alarms-Form

More information

Operating Instructions

Operating Instructions Innovative by tradition. Operating Instructions Control Unit SG-RSV 239 Version 1 1003986 SG-RSV 239/24 24 V= 1005372 SG-RSV 239/36 36 V= 1003271 SG-RSV 239 50-150 V= Mayser GmbH & Co. KG Örlinger Straße

More information

LEDsmart+ Slave Relay Device

LEDsmart+ Slave Relay Device Installation Guide MMSR Provides general purpose ON/OFF control via 2-wire trailing edge devices Compatible with Diginet MEDM Dimmer Diginet LEDsmart+ Dimmers (Rotary and Push Button versions) Diginet

More information

G-LOG Mobile Application

G-LOG Mobile Application G-LOG Mobile Application I N S T R U C T I O N M A N U A L Version 1.0.12 February 2015 CONTENTS 1. ABOUT THIS DOCUMENT... 3 2. INITIAL STEPS... 3 2.1. App installation... 3 2.2. Connection... 3 2.3. Power...

More information

Table of contents Page

Table of contents Page User Guide Prog-Box Thank you for purchasing a Hacker Brushless Motors product. The MASTER Prog-Box was developed in close cooperation with JETI and incorporates the latest technological developments.

More information

Pressure Transmitter and Reader of the PT-RF Series Manual

Pressure Transmitter and Reader of the PT-RF Series Manual Local Solutions For Individual Customers Worldwide Pressure Transmitter and Reader of the PT-RF Series Manual Contents 1 Safety instructions... 3 1.1 Intended use... 3 1.2 Specialist personnel... 3 1.3

More information

LCI Load Cell Junction Box with Fault Monitor

LCI Load Cell Junction Box with Fault Monitor LCI Load Cell Junction Box with Fault Monitor User Manual www.mantracourt.co.uk The LCI Load Cell Failure Alarm Manual Chapter 1 Introduction to the LCI...2 Chapter 2 Installing the LCI...3 Figure 2.1

More information

HI ma Simulator

HI ma Simulator Instruction Manual HI 931002 4-20 ma Simulator http://www.hannacan.com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments Product. Please

More information

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control Remote Control for Inverter RC-200 Owner's Manual Please read this manual before operating your RC-200 Remote Control Owner's Manual Index SECTION 1 Safety...3 SECTION 2 Description...3 SECTION 3 Layout

More information

Model Number Structure

Model Number Structure Digital Panel Meter CSM DS_E_3_1 Easy-to-use, w-cost Digital Panel Meter that Accepts DC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. Highly visible display

More information

1875 Smart Calibrator. Instruction Manual

1875 Smart Calibrator. Instruction Manual THORNTON Leading Pure Water Analytics Part No. 84386 1875 Smart Calibrator for 770MAX Multiparameter Analyzer/Transmitter Instruction Manual INTRODUCTION This manual covers operation of the Mettler- Toledo

More information

IPCB42501 / IPCB42551

IPCB42501 / IPCB42551 IPCB42501 / IPCB42551 Installation manual Version 03/2017 IPCB42501 IPCB42551 English translation of the original German user manual. Retain for future reference. uk Introduction Dear Customer, Thank you

More information

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~ Innovative by tradition. Control unit SG-EFS 104/2W EN Operating instructions Version 0.9 1005196 SG-EFS 104/2W 24 V=/~ Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

MTS-2000 USER S MANUAL

MTS-2000 USER S MANUAL MTS-2000 USER S MANUAL USER s MANUAL - March 2010 MTS-2000 METER TEST SYSTEM Pay special attention to the warnings and safety instructions that accompany the above symbol wherever it is found within this

More information

VW2106 VW Readout Manual

VW2106 VW Readout Manual VW2106 VW Readout Manual All efforts have been made to ensure the accuracy and completeness of the information contained in this document. RST Instruments Ltd reserves the right to change the information

More information

C-Bus Network Bridge 5500NB. Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

C-Bus Network Bridge 5500NB. Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT C-Bus Network Bridge 5500NB Series Installation Instructions REGISTERED DESIGN REGISTERED PATENT Contents 1.0 Description...3 1.1 Capabilities...3 1.2 Status Indicators...4 2.0 C-Bus Network Connections...5

More information

GMH Operating Manual for Digital Quick-Response Thermometer

GMH Operating Manual for Digital Quick-Response Thermometer H58.0.01.6C-02 Operating Manual for Digital Quick-Response Thermometer GMH 1170 WEEE-Reg.-Nr. DE93889386 GHM Messtechnik GmbH Standort Greisinger Hans-Sachs-Str. 26 D-93128 Regenstauf +49 (0) 9402 / 9383-0

More information

TETRIS 2500 High Impedance Active Probe. Instruction Manual

TETRIS 2500 High Impedance Active Probe. Instruction Manual TETRIS 2500 High Impedance Active Probe Instruction Manual Copyright 2018 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web:   IMPORTANT!!! 4300 WINDFERN RD #100 HOUSTON TX 77041-8943 VOICE (713) 973-6905 FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN A SAFE PLACE.

More information

RXTH DUAL ROOM SENSOR / SWITCH

RXTH DUAL ROOM SENSOR / SWITCH DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE

More information

PMDX-170 Slotted Optical Sensor

PMDX-170 Slotted Optical Sensor PMDX-170 Slotted Optical Sensor User s Manual Date: 20 May 2009 PMDX Web: http://www.pmdx.com 9704-D Gunston Cove Rd Phone: +1 (703) 372-2975 Lorton, VA 22079-2366 USA FAX: +1 (703) 372-2977 PMDX-170_Manual_10.doc

More information

Kramer Electronics, Ltd. USER MANUAL. Model: VA-1DVIN. Virtual EDID

Kramer Electronics, Ltd. USER MANUAL. Model: VA-1DVIN. Virtual EDID Kramer Electronics, Ltd. USER MANUAL Model: VA-1DVIN Virtual EDID Contents Contents 1 Introduction 1 2 Getting Started 1 3 Overview 2 3.1 Defining EDID 3 4 Your VA-1DVIN Virtual EDID 3 5 Connecting the

More information

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2 VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2 1 of 18 PREFACE Important Installation Information It is the purchasers responsibility to determine the suitability

More information

Electronic Temperature Controller. Instruction Manual Version

Electronic Temperature Controller. Instruction Manual Version Electronic Temperature Controller 701 Instruction Manual Version 1.00.01 Dear Customer, we have made up this operating manual in such a way that all necessary information about the product can be found

More information

Thermo-Anemometer Data Logger Model 1227

Thermo-Anemometer Data Logger Model 1227 Thermo-Anemometer Data Logger Model 1227 Quick Start Guide ENGLISH www.aemc.com Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using

More information

CO2 1% or 30%, Temperature & %RH, Diffusion Data Loggers

CO2 1% or 30%, Temperature & %RH, Diffusion Data Loggers CO2 1% or 30%, Temperature & %RH, Diffusion Data Loggers Models Covered ESCM 18 ESCM 19 ESCM 209 ESCM 210 ESCM 08-CC ESCM 16 ESCM 17 Save meter information for future reference Model Number: Serial Number:

More information

9040/9040UK. Users Manual. Phase Rotation Indicator

9040/9040UK. Users Manual. Phase Rotation Indicator 9040/9040UK Phase Rotation Indicator Users Manual PN 2438546 April 2005 2005 Fluke Corporation. All rights reserved. Printed in China All product names are trademarks of their respective companies. LIMITED

More information

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs INSTRUCTION MANUAL Model 421504 Dual Input RTD Thermometer Measures two temperatures simultaneously Dual RTD probe inputs Clock and Elapsed Timer functions Special functions include Data Hold, MIN/MAX/AVG,

More information

OZONE SWITCH Model OS-6. OS-6 Features

OZONE SWITCH Model OS-6. OS-6 Features USER MANUAL OZONE SWITCH Model OS-6 OS-6 Features The OS-6 is an industrial grade ozone controller and monitor. The OS-6 design is optimized for accuracy and ease of installation, setup and operation.

More information

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -... E39.0.1X.6C-01 Data logger for standard signals as of version 1.0 Operating Instruction T-Logg 120... T-Logg 120 W -... T-Logg 120 K -... GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße

More information

PWRguard PLUS Spring City Drive Waukesha, WI

PWRguard PLUS Spring City Drive Waukesha, WI PWRguard PLUS www.westmountainradio.com 1020 Spring City Drive Waukesha, WI 53186 262-522-6503 sales@westmountainradio.com 2016, All rights reserved. All trademarks are the property of their respective

More information

IVC-222HPII Precision Voltage/Current Calibrator

IVC-222HPII Precision Voltage/Current Calibrator IVC-222HPII Precision Voltage/Current Calibrator Table of Contents 1. Introduction 1.1 Customer Service................2 1.2 Unpacking.....................2 2. Operating Procedure...............3 3. Operating

More information

SIRIUS CAPACITOR MODULE User Manual. Model number: A-1.7C-M-SD-G Version 1.0; Release Date: April 2018

SIRIUS CAPACITOR MODULE User Manual. Model number: A-1.7C-M-SD-G Version 1.0; Release Date: April 2018 SIRIUS CAPACITOR MODULE User Manual Model number: 3550-48-A-1.7C-M-SD-G Version 1.0; Release Date: April 2018 Introduction The Sirius Capacitor Module ( Sirius ) is supercapacitor-based storage that uses

More information

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor Aluminum-detecting Proximity Sensor EEY CSM_EEY_DS_E_5_1 A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Non-ferrous metals, such as aluminum and brass, are detected.

More information

PWRcheck Spring City Drive Waukesha, WI

PWRcheck Spring City Drive Waukesha, WI PWRcheck www.westmountainradio.com 1020 Spring City Drive Waukesha, WI 53186 262-522-6503 sales@westmountainradio.com 2018 West Mountain Radio, All rights reserved. All trademarks are the property of their

More information

FDCCM1-MM-L & FDCCM1-MM-R

FDCCM1-MM-L & FDCCM1-MM-R Page 1 of 14 Installation and Operation Manual FDCCM1-MM-L & FDCCM1-MM-R MULTI-MENU CABIN CONTROL MODULE - WITH AUDIO (LEFT & RIHT) Page 2 of 14 FDCCM1-MM-L & FDCCM1-MM-R Multi-Menu Cabin Control Module

More information

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS

More information

RТTH DUAL ROOM SWITCH

RТTH DUAL ROOM SWITCH DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA

More information

DCM Digital Control Modules

DCM Digital Control Modules DCM Digital Control Modules TECHNICAL MANUAL Version 1.2 November 2011 Safety Precautions Caution Read Instructions: Read and understand all safety and operating instructions before using the equipment.

More information

DD-600. A member of the Data Dolphin Family of Data Logging Systems. Data Dolphin Installation and Usage Manual

DD-600. A member of the Data Dolphin Family of Data Logging Systems. Data Dolphin Installation and Usage Manual A member of the Data Dolphin Family of Data Logging Systems Real Time Wireless Monitoring Solution Data Dolphin Installation and Usage Manual Last Revision: May 2012-1 - Note to the user: This manual may

More information

TDM-170 TIMER DISPLAY

TDM-170 TIMER DISPLAY TDM-170 TIMER DISPLAY TECHNICAL MANUAL Version 1.1 August 2016 TDM-170 Timer Display Technical Manual Safety Precautions Caution Read Instructions: Read and understand all safety and operating instructions

More information

BrewTroller Phoenix. Owners Manual. Updated - March 14, 2016 BREWTROLLER PHOENIX 1

BrewTroller Phoenix. Owners Manual. Updated - March 14, 2016 BREWTROLLER PHOENIX 1 BrewTroller Phoenix Owners Manual Updated - March 14, 2016 BREWTROLLER PHOENIX 1 2016 BrewTroller All Rights Reserved. Product warranty or service will not be extended if: (1) the product is repaired,

More information

User s Guide RDXL6SD-USB. Temperature Data Logger with USB. Shop online at omega.com

User s Guide RDXL6SD-USB. Temperature Data Logger with USB. Shop online at omega.com TM User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info RDXL6SD-USB Temperature Data Logger with USB U.S.A. Headquarters: omega.com info@omega.com Servicing

More information

WARRANTY & LIMITATION OF LIABILITY

WARRANTY & LIMITATION OF LIABILITY MUX-2 WARRANTY & LIMITATION OF LIABILITY 1. ROTEM warrants that the product shall be free of defects in materials or workmanship and will conform to the technical specification for a period of 1 (one)

More information

Zodiac WX QUICK START GUIDE

Zodiac WX QUICK START GUIDE Zodiac WX QUICK START GUIDE Oct 2017 - Page 1 - Important Information Limited warranty: Northbound Networks warrants that the Zodiac WX will be free from defects in material or workmanship for a period

More information

SLUG DATA-LOGGER MANUAL. YieldPoint Inc. JULY 2009

SLUG DATA-LOGGER MANUAL. YieldPoint Inc. JULY 2009 SLUG DATA-LOGGER MANUAL YieldPoint Inc. JULY 2009 Copyright 2009 by YieldPoint Inc. The Information contained herein is the exclusive property of YieldPoint Inc., except as otherwise indicated and shall

More information

ESV1018 Quantum Illuminator Cabinet INSTRUCTION MANUAL

ESV1018 Quantum Illuminator Cabinet INSTRUCTION MANUAL ESV1018 Quantum Illuminator Cabinet INSTRUCTION MANUAL Universal Power Supply EVS1018 Illuminated Cabinet Battery Pack: Optional Charts Charts HOTV Charts Letter Charts and Tumbling E More charts available

More information

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

OPERATING AND SERVICE MANUAL. Universal Interface Device 47 OPERATING AND SERVICE MANUAL Universal Interface Device 47 MAGNA-POWER ELECTRONICS, INC. 39 ROYAL ROAD, FLEMINGTON, NJ 08822 May 24, 2012 SAFETY NOTICE Universal Interface Device 47 (UID46) connects

More information

Instruction Manual RS-1660

Instruction Manual RS-1660 Instruction Manual RS-1660 Transformer Turns Ratio Meter This unit passes the following tests: Safety Symbols EN 61010-1: 2010 EN 61010-2-030: 2010 CAT IV 50V Pollution Degree 2 EN 61326-1: 2013 (CISPR

More information

4-20mA Display. Installation and Operation Manual. Rev 4/3/2019 Part #

4-20mA Display. Installation and Operation Manual. Rev 4/3/2019 Part # 4-20mA Display Installation and Operation Manual Rev 4/3/2019 Part # 12050769 Table of Contents DOCUMENTATION CONVENTIONS... 2 Section 1: System Description... 3 Function and Theory... 3 Section 2: System

More information

SD1306. Speed Dome IP Camera. Quick User Guide

SD1306. Speed Dome IP Camera. Quick User Guide SD1306 Speed Dome IP Camera Quick User Guide Table of Contents I. Camera Introduction... 1 1. Package Contents... 1 2. Hardware Installation... 2 2.1 Factory Default... 6 3. SD card Compatibility List...

More information

WARRANTY & LIMITATION OF LIABILITY

WARRANTY & LIMITATION OF LIABILITY MUX-485 WARRANTY & LIMITATION OF LIABILITY 1. ROTEM warrants that the product shall be free of defects in materials or workmanship and will conform to the technical specification for a period of 1 (one)

More information

Two Channel 48 Volt Phantom Power Supply. Artcessories. User's Manual

Two Channel 48 Volt Phantom Power Supply. Artcessories. User's Manual Two Channel 48 Volt Phantom Power Supply Artcessories User's Manual IMPORTANT SAFETY INSTRUCTION READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage

More information

Benchmark Plus Microplate Reader User Manual. This Instrument for Laboratory Use Only Rev C

Benchmark Plus Microplate Reader User Manual. This Instrument for Laboratory Use Only Rev C Benchmark Plus Microplate Reader User Manual This Instrument for Laboratory Use Only 4100172 Rev C 4100172 Rev C Benchmark Plus System with Incubator Catalog Number 170-6930 Benchmark Plus Reader with

More information