i-accurate_gb_ High precision air-conditioners for data centres cooling, with new inverter technology and R-410A refrigerant, from 6 to 150 kw

Size: px
Start display at page:

Download "i-accurate_gb_ High precision air-conditioners for data centres cooling, with new inverter technology and R-410A refrigerant, from 6 to 150 kw"

Transcription

1 i-accurate_gb_ igh precision air-conditioners for data centres cooling, with new inverter technology and R-410A refrigerant, from 6 to 150

2 Coming form 40 years experience in air conditioning and process cooling, i-accurate is the ultimate solution for technical rooms and data centres cooling: Precise temperature and humidity control Complex IT centres require to keep temperature and humidity within very strict parameters. This is particularly difficult due to extremely variable thermal loads, that require very high cooling capacity at full load, in order to avoid to compromise the correct operation of the IT machines when they are more necessary. The massive use of the new inverter technology on PAC units for technical rooms, makes possible to keep ambient temperature and humidity constant even with very strong loads variations, preventing dangerous temperature variations, almost unavoidable with traditional ON/OFF compressor driven units. Cooling IT load igh efficiency at partial loads Data Center energy consumption Most energy consumed by modern data centres is due to ambient cooling. In more and more cases the cost due to cooling are higher than those caused by data exchange. In systems characterized by 24 operations, also the slightest compromise concerning efficiency has dramatic implications in the operating costs of the whole data centre. ence it is crucial that the air conditioning system of the centre works effectively also at part loads, which are the most frequent operating condition, in order to reduce the overall operating cost. i-accurate strong point is exactly efficiency at part loads. Thanks to the adoption of inverter DC brushless compressors up to 30 and inverter AC for lager capacities, these units can reduce by 50% consumptions at part load, if compared to a traditional ON/OFF compressor. This is made possible also thanks to the advantages of variable air flow enabled by last generation EC fans. Versatility From Climaveneta s experience i-accurate high precision air conditioners, available both as direct expansion and free-cooling versions are the most efficient and reliable solution on the market. The many types of structures used as technical areas and the need to optimize their dimensions, require flexible solutions, that can adapt to any room, always granting perfect control and highest efficiency. This means complete flexibility, both as concerns capacities (from 6 to 150 Inverter), as well as configuration and system with 5 different cooling solutions, including FREECOOING with R410A. 2 l 3

3 Efficiency, versatility and reliability. These are the strong points that make i-accurate a point of reference in high precision air conditioning. Advantages that come from distinctive technological choices in every aspect of this units. Inverter technology -10% NEW GENERATION EC fans Annual power consumption The inverter driven compressor, though the variable frequency, modulates the power capacity provided, hence enabling to optimize the performances at part load, increasing efficiency. Moreover a larger capacity can be reached at full load, thus ensuring that the required temperature will be reached in a shorter time. Afterwards temperature variations can be easily controlled with minimized energy consumption, because once the set is reached, the compressor works at part load, reducing energy consumption and effectively maintaining the desired conditions. Plug-in (AC) EC (DC) -15% EC-New generation (DC) -25% The high efficiency EC fan reduces both noise levels as well as energy consumption, and assures a variable air flow at part loads, optimizing the operating costs of the unit. Main features Further noise level reduction 4-5 db(a) Further absorbed power reduction by 15% An advanced logic simultaneously manages fans and inverter compressors modulation, with savings at part loads up to 50%. 100% In case of low z Operation 55% Max 70% 30% In this respect i-accurate represents the ultimate solution in high precision air conditioning, with the most updated compressors, both DC inverter brushless, for units from 7 to 30 and Inverter AC for larger capacities. Both solutions allow to perfectly adapt the unit s performance to the real requirements of the building even at part load, which represent more than 75% of the operating time of the system. This ensures an energy saving up to 50% higher than solutions based on traditional ON/OFF compressors. EC fans also in the remote condensers The use of EC technology even on the remote condenser fan assures a further average reduction of noise levels by 10%, together with a strong reduction of energy consumption by 45% compared with traditional condensers with AC technology. Constant speed AC Inverter DC Inverter Intelligent Control i-accurate, has an intelligent regulation, that allows the complete control of all the unit s parameters in any condition. i-accurate control is completely open and can be set according to the specific needs of the customer, either on site or in advance when the unit is produced. Electronic thermostatic valve The electronic valve is used in a very peculiar way in order to guarantee optimum operating conditions at the evaporator. The INVERTER units come with electronic expansion valves as standard. These valves have a much wider modulation capacity; it stands out for its quality of control and for its capacity to quickly reach and maintain the operating stability of the unit and joined with INVERTER compressor technology allows a quick fluctuation-free regulation, and therefore a highly accurate adjustment to the swings of load and ambient conditions. 4 l 5

4 All-round flexibility seen as a service offered for any type of system. i-accurate comes with capacities from 6 to 150 in the direct expansion version with air cooling (i-axo / i-axu) and water cooling (i-awo / i-awu) and capacities from 11 to 130 in version dual fluid (i-ado / i-adu and i-ato / i-atu) and free cooling (i-afo / i-afu). Types of cooling i-axo/i-axu DIRECT EXPANSION AIR COOED, with INVERTER compressor for heat transfer is used in these direct expansion units. The air in the room is therefore treated in the evaporating coil containing the refrigerant. The condensation heat is dispersed to a fresh air condenser that with speed control for condensing control, optimise the condensation pressure even in adverse temperature conditions. Units provided per standard with EC inverter fans who represents today the best solution for energy saving. i-awo/i-awu DIRECT EXPANSION WATER COOED, with INVERTER compressor for heat transfer is used in these direct expansion units. The air in the room is therefore treated in the evaporating coil containing the refrigerant. The condensation heat is dispersed in an internal platetype exchanger connected in turn to a water circuit. The water of condensation may come from a well, local water mains or closed circuits such as cooling towers or dry coolers. Units provided per standard with EC inverter fans who represents today the best solution for energy saving. NB: for negative External T values antifreeze fluids must be used to protect the system i-ato/i-atu Dual Fluid Inverter These units are per standard provided with a dual cooling systems who never work simultaneously. A PRIMARY circuit, made by a chilled water circuit (CW) generally connected to an external chiller, plus a SECONDARY circuit in direct expansion (DX) water cooled, who is considered as BACK-UP. Such units are particulary indicated anywhere REIABIITY, SAFETY and REDUNDANCY are required. Units provided per standard with EC inverter fans who represents today the best solution for energy saving. i-afo/i-afu Free Cooling Inverter These units are per standard provided with a dual cooling systems who are often working simulateusly along the year. A PRIMARY direct expansion circuit (DX) plus a SECONDARY chilled water circuit (CW) generally connected to an external dry cooler who is considered as "support" to the primary one. Such units are particulary indicated anywhere EFFICIENCY & ENERGY SAVING are required. Units provided per standard with EC inverter fans who represents today the best solution for energy saving. i-ado/i-adu Dual Fluid Inverter These units are per standard provided with a dual cooling systems who never work simultaneously. A PRIMARY circuit, made by a chilled water circuit (CW) generally connected to an external chiller, plus a SECONDARY circuit in direct expansion (DX) air cooled, who is considered as BACK-UP. Such units are particulary indicated anywhere REIABIITY, SAFETY and REDUNDANCY are required. Units provided per standard with EC inverter fans who represents today the best solution for energy saving. Airflow configuration OVER The versions called OVER with air outflow from the top generally have the air intake at the front, rear or bottom of the unit, according to customer choice, and the outflow from the top is along ducts behind suspended ceilings or front delivery plenums. OVER unit with front intake and delivery plenum OVER unit with front intake and top delivery OVER unit with underfloor intake and top delivery OVER unit with rear intake and top delivery UNDER The versions called UNDER with air outflow under the floor have the air intake on the top of the unit taking air directly from the environment or through intake ducts or plenums. UNDER unit with top intake and front delivery plenum UNDER unit with top intake and undefloor delivery 6 l 7

5 COOING r FC R-410A i-accurate range unit with R410A & inverter driven scroll compressor from 6 to 150, air cooled. ACCURATE INVERTER i-ax Power supply V/Ph/z n Circuits/Compressors PERFORMANCES igh Speed Total cooling capacity (1) Sensible cooling capacity (1) ow speed Total cooling capacity (1) Sensible cooling capacity (1) Total cooling capacity (1) Sensible cooling capacity (1) Nominal air flow volume m 3 /h Fan absorbed power Sound pressure level (2) db(a) UMIDIFIER EECTRICA EATERS Steps DIMENSIONS P F2 F3 F4 F5 F6 F7 F7 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 R410A R410A R410A R410A R410A R410A R410A 1/1 1/1 1/1 2/2 2/2 2/3 2/3 16,60 28,07 53,14 68,40 84,68 133,9 149,8 16,60 28,07 50,30 67,30 84,68 115,3 123,2 1,00 1,00 0,95 0,98 1,00 0,86 0,82 4,09 7,14 13,92 16,47 21,03 32,05 36,2 3,65 3,24 3,12 3,25 3,12 3,44 3,48 6,27 10,62 23,68 22,06 22,70 23,1 23,1 6,27 10,62 23,68 22,06 22,70 23,1 23,1 1,00 1,00 1,00 1,00 1, ,24 1,96 4,85 4,82 4,83 5,08 5,08 20,42 34,77 56,52 85,31 93, ,44 31,10 51,30 74,60 89, ,90 0,89 0,91 0,87 0, ,66 8,00 15,24 22,49 24, ,47 1,51 3,13 4,57 6,1 6,9 6, ,75 3,75 3, ,25 11, (1) Indoor conditions :24 C-50% Condensing temp.45 C - ESP 20Pa (2) Measured at 1,5 m height, 2 m in front of the unit in free field 8 l 9

6 COOING r FC R-410A COOING r FC R-410A i-accurate range unit with R410A & inverter driven scroll compressor from 6 to 150, water cooled. Close control unit dual fluid, air cooled direct expansion. i-accurate range unit with R410A & inverter driven scroll compressor from 11 to 130, air cooled dual fluid. i-accurate INVERTER i-aw Power supply V/Ph/z n Circuits/Compressors PERFORMANCES igh Speed Total cooling capacity (1) Sensible cooling capacity (1) ow speed Total cooling capacity (1) Sensible cooling capacity (1) Total cooling capacity (1) Sensible cooling capacity (1) PATES CONDENSER N Water flow l/h Pressure drop Nominal air flow volume m 3 /h Fan absorbed power Sound pressure level (2) db(a) UMIDIFIER EECTRICA EATERS Steps DIMENSIONS P F2 F3 F4 F5 F6 F7 F7 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 R410A R410A R410A R410A R410A R410A R410A 1/1 1/1 1/1 2/2 2/2 2/3 2/3 17,4 29, ,3 91,5 140,6 156, ,6 50,8 69,5 89,8 118,1 126,4 0,98 0,98 0,92 0,96 0,98 0,84 0,81 3,68 6, ,5 19,6 29,1 33,04 4,19 3,71 3,41 3,79 3,56 3,91 3,93 7,27 12,3 25,7 23,6 25,4 25,7 25,7 7,27 12,3 25,7 23,6 25,4 25,7 25, ,96 1,43 3,83 3,99 3,92 3,94 3,94 21,69 35,3 58,07 88,03 100, ,96 31,1 52,00 75,9 93, ,87 0,88 0,90 0,86 0, ,97 7,83 14,46 21,00 23, ,47 1,51 3,13 4,57 6,1 6,9 6, ,75 3,75 3, ,25 11, i-accurate INVERTER i-ad Power supply V/Ph/z n Circuits/Compressors PERFOMANCES igh speed Total cooling capacity (1) Sensible cooling capacity (1) ow speed Total cooling capacity (1) Sensible cooling capacity (1) Total cooling capacity (1) Sensible cooling capacity (1) PERFOMANCES CW Total cooling capacity (2) Sensible cooling capacity (2) Water flow (2) l/h Pressure drop Nominal ai flow volume m 3 /h Fan absorbed power Sound pressure level (5) db(a) UMIDIFIER EECTRICA EATERS Steps DIMENSIONS P F3 F4 F5 F6 F7 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 R410A R410A R410A R410A R410A 1/1 1/1 2/2 2/2 2/3 27,5 51,5 67,4 89,6 122,6 27,5 49,5 66,6 85,1 107,9 1 0,96 0,99 0,95 0,88 6,83 14,1 16,8 21,8 31,7 3,19 2,89 3,04 3,20 3,18 11,3 21,3 19, ,4 11,3 21,3 18, , , ,05 4,9 4,88 4,95 5,07 32,54 54,47 76,6 99,1-30,15 50,78 70,6 89,4-0,93 0,93 0,92 0,90-9,21 14,41 20,2 25,4-29,5 51,4 67, ,7 27,6 47,5 64, ,5 0,94 0,92 0,95 0,93 0, ,78 3,69 5,38 6,24 6, ,75 3, , (1) Indoor conditions :24 C-50% Water C - ESP 20Pa (2) Measured at 1,5 m height, 2 m in front of the unit in free field (1) Indoor conditions : 24 C-50%, Condensing temp. 45 C - ESP 20Pa (2) Indoor conditions : 24 C-50%, Water 7-12 C - ESP 20Pa (5) Measured at 1,5 m height in front of the unit in free field 10 l 11

7 COOING r FC R-410A COOING r FC Close control unit dual fluid, air cooled direct expansion i-accurate range unit with R410A & inverter driven scroll compressor from 11 to 130, water cooled, dual fluid. Close control unit dual fluid, air cooled direct expansion. i-accurate range unit with R410A & inverter driven scroll compressor from 11 to 130, free cooling source. i-accurate INVERTER i-at Power supply V/Ph/z n Circuits/Compressors PERFOMANCES igh speed Total cooling capacity (1) Sensible cooling capacity (1) ow speed Total cooling capacity (1) Sensible cooling capacity (1) Total cooling capacity (1) Sensible cooling capacity (1) WATER CONDENSER PATE Quantity Condensing water flow (1) l/h Pressure drop DX functioning PERFOMANCES CW Total cooling capacity (2) Sensible cooling capacity (2) Water flow (2) l/h Pressure drop Nominal air flow volume m 3 /h Fan absorbed power Sound pressure level (5) db(a) UMIDIFIER EECTRICA EATERS Steps DIMENSIONS P F3 F4 F5 F6 F7 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 R410A R410A R410A R410A R410A 1/1 1/1 2/2 2/2 2/3 28,6 53,5 71,4 92,9 128,6 28,4 50,3 68,5 86,2 110,4 0,99 0,94 0,96 0,92 0,86 6,15 13,1 14,7 20,2 28,6 3,61 3,19 3,56 3,51 3,62 12,4 23,2 21,2 22,9 24,5 12,4 23,2 18,9 21,7 24, ,89 0,94 1 1,49 3,79 3,82 3,88 3,91 33,3 56,26 80,3 102,2-30,47 51,42 72,0 90,2-0,92 0,91 0,90 0,88-8,72 14,4 18,3 23, ,5 51,4 67, ,7 27,6 47,5 64, ,5 0,93 0,92 0,95 0,93 0, ,78 3,69 5,38 6,24 6, ,75 3, , i-accurate INVERTER i-af PERFOMANCES Total cooling capacity (1) Total cooling capacity (1) Sensible cooling capacity (1) Quantity Pressure drop DX functioning Total cooling capacity (2) Sound pressure level (5) db(a) EECTRICA EATERS F3 F4 F5 F6 F7 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 R410A R410A R410A R410A R410A 1/1 1/1 2/2 2/2 2/3 28,6 53,5 71,4 92,9 128,6 28,4 50,3 68,5 86,2 110,4 0,99 0,94 0,96 0,93 0,86 6,15 13,1 14,7 20,2 28,6 3,61 3,19 3,56 3,51 3,62 12,4 23,2 21,2 22,9 24,5 12,4 23,2 18,9 21,7 24, ,89 0,95 1 1,49 3,79 3,82 3,88 3,91 33,3 56,26 80,3 102,2-30,47 51,42 72,0 90,2-0,92 0,91 0,90 0,88-8,72 14,4 18,3 23, ,3 43,5 57,7 78,1 104,5 24,3 43,5 57,7 78,1 94, , ,78 3,69 5,38 6,24 6, ,75 3, , (1) Indoor conditions: 24 C-50%, Water C - ESP 20Pa (2) Indoor conditions: 24 C-50%, Water 7-12 C - ESP 20Pa (5) Measured at 1,5 m height in front of the unit in free field (1) Indoor conditions: 24 C-50%, Water C - ESP 20Pa (2) Water IN 10 C water flow as DX mode - ESP 20Pa (5) Measured at 1,5 m height in front of the unit in free field 12 l 13

8 All around the world, in the most important data centres, and in all projects where efficiency, quality and reliability are a must, i-accurate high precision air conditioners are the best guarantee Sir Francis Bacon British Philosopher ( ) IBM Mompellier ead offices Suvidha Eads - Casa Over 24 units Accurate in different installations, over 400 total capacity, provided by: Accurate AXU 50, Accurate AXU 88, Accurate AXU 40, Accurate AXU 55, Accurate AXO 7, Accurate AXO 10 India Dual Fluid units, 8 Accurate ADU60BE, 4 Accurate ADU 30 BE Spain Accurate DXO 18 Telefonica Cile Túneles M-30 Chile Over 20 DX aircooled units among which, Accurate AXO 55, Accurate AXU 60, Accurate AXO 20, Accurate AXO 07, Accurate AXU 50 Spain Accurate DXU 20 / 10 attelkom argest Telecounications and IT network in atvia Over Accurate 24 units in different installations, over 400 total capacity, provided by: Accurate AXU 50, Accurate AXU 88, Accurate AXU 40, Accurate AXU 55, Accurate AXO 7, Accurate AXO 10 Buygues Telecom France Accurate ACU 25 EC, Accurate ACU 70 EC, Accurate ACU 70 EC, Accurate ACU 90 EC, Accurate ADU 20, Accurate ADU l 15 Alphabank Romania 8 Dual fluid units, Accurate ATO 77BE, Accurate ATO 60BE Gazprom Russia Accurate DU 077BE, Accurate DU 039ME ispasat Verwaltung der AOK Deutschland Caffemacherreihe Nr. 16 Offices Spain Accurate DXU 39 / 29 / 20 / 18 Berlin - Germany DX watercooled units, Accurate AWU 26 amburg - Germany DX watercooled units, Accurate AFU 50

Rack cooling solutions for high density racks management, from 10 to 75 kw

Rack cooling solutions for high density racks management, from 10 to 75 kw Rack cooling solutions for high density racks management, from 10 to 75 Superior efficiency, high reliability, low energy consumption Modern data center are characterized by 24/7 operation all year long.

More information

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE

More information

Climaveneta for Data Center. The Milestone Of Green Data Center Cooling Technology

Climaveneta for Data Center. The Milestone Of Green Data Center Cooling Technology Climaveneta for Data Center The Milestone Of Green Data Center Cooling Technology The future of data centers brings both advanced technologies and exponential data exchange that strongly increase heat

More information

Reliability and extended operation

Reliability and extended operation CLIMAVENETA TELECOMSOLUTIONS Units for mobile telecounication applications, with free cooling and full DC Inverter technology. 1,5 20. Low operational and maintenance costs Wide range of full inverter

More information

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw IT COOLING CLOSE CONTROL AIR CONDITIONERS CHILLED WATER HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw 3 Versions available Single chilled water coil Double chilled water coil High temperature IT COOLING

More information

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 0 Jl. Malibu Raya, Cengkareng Jakarta Barat 70 Indonesia Phone + 4 4 www.climanusa.com Marketing features prominent presence on the world

More information

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101 Nick Gangemi Regional Sales Manager Data Aire Agenda Exactly what are we talking about ASHRAE TC 9.9 Design best practices

More information

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres Product Brochure DENCO Close Control Units Row-DENCO High Density Cooling for Data Centres Data Centre Cooling Through a history in close control, we have developed a broad and deep understanding of how

More information

IT Air Conditioning Units

IT Air Conditioning Units IT Air Conditioning Units Modern Flexible Effective Energy Saving CoolTeg Plus and CoolTop overview CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC CoolTop Installation Between IT racks On top of IT rack

More information

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS Cooling > Highly efficient cooling products for any IT application. DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com End-to-End Cooling Solutions from the Closet to the Data

More information

IT COOLING DATA CENTER COOLING THE MILESTONE OF GREEN DATA CENTER COOLING TECHNOLOGY

IT COOLING DATA CENTER COOLING THE MILESTONE OF GREEN DATA CENTER COOLING TECHNOLOGY IT COOLING DATA CENTER COOLING THE MILESTONE OF GREEN DATA CENTER COOLING TECHNOLOGY IT COOLING RC for IT COOLING RC approach for perfect data center cooling THE FUTURE OF DATA CENTERS BRINGS BOTH ADVANCED

More information

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors. Aquaflair Uniflair TRAC, TRAF and TRAH Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors 120-350kW Uniflair TRA ranges 115-350kW Air-cooled Chillers Cooling, Free cooling

More information

Efficiency of Data Center cooling

Efficiency of Data Center cooling Efficiency of Data Center cooling Comparison of data room layouts and cooling systems Bohumil Cimbal Product manager for Cooling Systems in CONTEG Company Objective Basic questions between investor and

More information

APPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS PRODUCT LEAFLET. Capacity from 600 to 2,010kWr. Engineered for flexibility and performance

APPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS PRODUCT LEAFLET. Capacity from 600 to 2,010kWr. Engineered for flexibility and performance APPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS Capacity from 600 to 2,010kWr Engineered for flexibility and performance PRODUCT LEAFLET THE AWS SERIES OFFERS TOP EFFICIENCY, LOW SOUND LEVELS AND FLEXIBLE

More information

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Future of Cooling High Density Equipment Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Agenda Issues facing the Data Center Managing the explosive

More information

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling IBM Symposium 2008 Data Center Cooling EC Systems for HVAC architecture and Direct air Cabinet Cooling Presented by David J. Spofford Product Manager IT/Telecomm 1 Agenda Data Center trends for IT and

More information

PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers

PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers TM PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers WE ARE VERTIV Vertiv, formerly Emerson Network Power, designs, builds, and services mission critical technologies that

More information

Precision Cooling Mission Critical Air Handling Units

Precision Cooling Mission Critical Air Handling Units M I S S I O N C R I T I CA L C O O L I N G Precision Cooling Mission Critical Air Handling Units Global Expertise for Precision Cooling Solutions STULZ is a privately owned, global manufacturer of highly

More information

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers TM PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers WE ARE VERTIV Vertiv, formerly Emerson Network Power, designs, builds, and services mission critical technologies that enable

More information

Thermal management. Thermal management

Thermal management. Thermal management Thermal management Thermal management Managing thermal loads is a major challenge for all Data Centre operators. Effecting proper control of the thermal environment drives energy consumption and ultimately

More information

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw IT COOLING EVAPORATIVE COOLING SYSTEM 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 8 TO 3 kw IT COOLING EVAPORATIVE COOLING SYSTEM ADIABATIC COOLING FOR HIGH EFFICIENCY - Variable

More information

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA 99 glide air cooled liquid chillers ND free cooling chillers glider 178 1328 Energy Class More efficient + B C D E F G Less efficient R134a CLSS SHELL C E C FREE COOLING 100 air cooled liquid chiller and

More information

Ecotel Free Cool 5-15kW

Ecotel Free Cool 5-15kW Precision Air Conditioning Free-cooling Ecotel Free Cool 5-15kW + + Self-contained compact outdoor cabin cooler + + 100% free-cooling + + -48V DC supply option + + Easy serviceability (front component

More information

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers Precision Cooling for Business-Critical Continuity Liebert HPC-S Designed for the Efficient Cooling of Small Data Centers Liebert HPC-S: Enhanced Efficiency Freecooling Chiller Higher energy costs, limited

More information

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability Liebert AFC from 500 to 1700 kw The Adiabatic Freecooling Solution with Top-Tier Availability Liebert AFC from 500 to 1700 kw Vertiv Vertiv designs, builds and services mission critical technologies that

More information

MOLLIER DIAGRAM CAN BE IMPROVED!

MOLLIER DIAGRAM CAN BE IMPROVED! MOLLIER DIAGRAM CAN BE IMPROVED! IMPROVED BASIC COOLING CIRCUIT PERFORMANCE EFFICIENCY USING AN ECONOMISER Eng. Jonny Malachi, VP Operations, Mashav Refrigeration and Air Conditioning Engineering Ltd.

More information

Liebert. HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers

Liebert. HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers Liebert HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers Liebert HPC-S FREE COOLING CHILLER Getting To A PUE Of 1.2 Free cooling data center chillers are designed to

More information

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System A Data Center Heat Removal System That Saves... Infrastructure Power Water up to 40% up to 80% up to 85% Discover Inertech s Award-winning Data Center Heat Removal System A Cool Solution; A Breakthrough

More information

Liebert. PDX from 15 to 165 kw. Direct Expansion Solution for Small and Medium Data Centers

Liebert. PDX from 15 to 165 kw. Direct Expansion Solution for Small and Medium Data Centers Liebert PDX from 5 to 65 Direct Expansion Solution for Small and Medium Data Centers LIEBERT PDX from 5 to 65 Vertiv Vertiv designs, builds and services mission critical technologies that enable the vital

More information

DUCTED SPLIT SYSTEMS With Scroll compressors

DUCTED SPLIT SYSTEMS With Scroll compressors DUCTED SPLIT SYSTEMS With Scroll compressors 2 Benefits TOTAL COMFORT ON WIDE AREAS The Ducted Blower Split Systems for light commercial applications of DXDXT-M/K series are the ideal solution for keeping

More information

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers Liebert HPC Freecooling Scroll Chillers for the Efficient Cooling of Data Centers Liebert HPC: Freecooling Solutions for Increased Data Center Efficiency and PUE of 1.1 Freecooling data center chillers

More information

Power and Cooling for Ultra-High Density Racks and Blade Servers

Power and Cooling for Ultra-High Density Racks and Blade Servers Power and Cooling for Ultra-High Density Racks and Blade Servers APC White Paper #46 Richard L. Sawyer Director of Data Center Technology American Power Conversion Company 2005 APC corporation What has

More information

Liebert. AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability CERTIFIED HVAC-HYGIENE.

Liebert. AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability CERTIFIED HVAC-HYGIENE. Liebert AFC from 500 to 1450 kw The Adiabatic Freecooling Solution with Top-Tier Availability CERTIFIED HVAC-HYGIENE Conformity of the device Vertiv Liebert AFC with the hygiene requirements of the guideline

More information

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

ZTE ZXCR Series DX In-Row Air Conditioning Product Description ZTE ZXCR Series DX In-Row Air Conditioning Product Description Requirements & Challenges Due to the rapid development of telecommunication technology, the related IT equipment s power consumption is increase

More information

Ecoflair Air Economizers

Ecoflair Air Economizers Ecoflair Air Economizers Cooling to maximize value for the cloud schneider-electric.com/ecoflair Life is On Schneider Electric 1 Ecoflair takes data center efficiency to new heights 2 Imagine cooling your

More information

2018 Product overview

2018 Product overview 2018 Product overview Project conditioning Evolution goes on During these years, the activity of EMICON has been developed with the production of liquid chillers for conditioning and industrial applications,

More information

Liebert PDX. The Cooling Solution for Small and Medium Data Centers. Digital Scroll. Part Load. Competent Partner Efficiency

Liebert PDX. The Cooling Solution for Small and Medium Data Centers. Digital Scroll. Part Load. Competent Partner Efficiency Liebert PDX The Cooling Solution for Small and Medium Data Centers Competent Partner Efficiency Digital Scroll Part Load icom Control TCO Optimization Integrated Solution Operational Cost Reduction New

More information

Liebert HPM from 4 kw to 100 kw

Liebert HPM from 4 kw to 100 kw Precision Cooling for Business-Critical Continuity Liebert HPM from 4 kw to 100 kw Efficient Direct Expansion Cooling for Data Centers With R410A Refrigerant Whether a data center houses three or 200 IT

More information

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant Your Solution For Energy and Cost Savings McQuay Packaged Chiller Plant Innovative Solutions for Your Chiller Plant McQuay packaged chiller plants provide energy efficient chillers integrated with pumps,

More information

Application Manual. Shark. Software for the simulation of refrigeration equipment and air conditioners

Application Manual. Shark. Software for the simulation of refrigeration equipment and air conditioners Page 1 of 184 Software for the simulation of refrigeration equipment and air conditioners Index Software for the simulation of refrigeration equipment and air conditioners... 1 : application description

More information

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

Motivair MLC-SC Air-Cooled Scroll Chillers Tons INNOVATE DESIGN APPLY www.motivaircorp.com Motivair MLC-SC Air-Cooled Scroll Chillers 100 285 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Businesses who function in today s advanced

More information

Total Modular Data Centre Solutions

Total Modular Data Centre Solutions Sector Data Centre Total Modular Data Centre Solutions www.airedale.com BRITISH MANUFACTURER ENERGY EFFICIENCY CONTROLS SERVICE TRAINING 01 Standardised Modular Designs to fit your needs Our modular system

More information

Liebert PDX from 15 to 120 kw

Liebert PDX from 15 to 120 kw Liebert PDX from 5 to 0 kw The Thermal Management Solution for Small and Medium Data Centers Electronic Expansion Valve Efficiency Digital Scroll Partial Load icom Control TCO Optimization Integrated Solution

More information

Communication Register Map - Uniflair Cooling

Communication Register Map - Uniflair Cooling DIGITAL 0 1 1 - - - - DIGITAL 1 2 2 System On (Fan) 0 or 1 boolean R DIGITAL 2 3 3 Compressor 1 0 or 1 boolean R DIGITAL 3 4 4 Compressor 2 0 or 1 boolean R DIGITAL 4 5 5 Compressor 3 0 or 1 boolean R

More information

ENCLOSURE HEAT DISSIPATION

ENCLOSURE HEAT DISSIPATION ENCLOSURE HEAT DISSIPATION DATA CENTER SOLUTIONS A White Paper by Great Lakes Case & Cabinet Company www.werackyourworld.com 814.734.7303 Page 2 Introduction Dangerous heat levels inside an enclosure threaten

More information

4-step Chiller and Heat Pump Controller

4-step Chiller and Heat Pump Controller 4-step Chiller and Heat Pump Controller Technical Data Sheet GENERAL DESCRIPTION MODELS CODE MODEL DESCRIPTION MW324000 ECH 420 HEAT PUMP WITH 4 STEPS/ 2 CIRCUITS + MODBUS MW324005 ECH 420/V WITH SCREW

More information

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM. HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM. SYSTEM LOGICA is the most advanced alternative to the problem of cooling of server rooms MONTAIR is the trademark which represents excellence on the market

More information

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America 7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer

More information

THE EUROPEAN REFERENCE

THE EUROPEAN REFERENCE THE EUROPEAN REFERENCE Eurovent Certified Performances certification for IT COOLING UNITS Data Centre World 2019 - London Morgane LAJEUNESSE Project Manager m.lajeunesse@eurovent-certification.com Agenda

More information

Liquid Cooling Package LCP Cooling Systems

Liquid Cooling Package LCP Cooling Systems Liquid Cooling Package LCP Cooling Systems 2 Rittal LCP Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative

More information

Improving the climate for data centers

Improving the climate for data centers Maximum performance for cool computers Improving the climate for data centers We create a good indoor climate. Supply air Return air Return air Outside air Exhaust air Pressure floor Our ventilation technology

More information

Impact of Air Containment Systems

Impact of Air Containment Systems White Paper June 2012 WP-20 Impact of Air Containment Systems Reducing Energy Consumption Introduction: The Importance of Maintaining Data Center Cooling Energy Efficiency Data centers are mission-critical

More information

Liquid Cooling Package LCP Cooling Systems

Liquid Cooling Package LCP Cooling Systems Liquid Cooling Package LCP Cooling Systems 2 Rittal LCP The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure,

More information

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers INNOVATE DESIGN APPLY www.motivaircorp.com MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers ½ - 100 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Motivair is a world-class

More information

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER Applications in Diverse Climates within Europe, Middle East and Africa Freecooling, Evaporative and Adiabatic Cooling Technologies

More information

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months TWO FINANCIAL IMPACT STUDIES Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months TWO FINANCIAL IMPACT STUDIES Seal IT Equipment Cabinets for Significant

More information

Data Center Optimized Controls

Data Center Optimized Controls Data Center Optimized Controls Controls Agenda 30 min. Emerson Control Products icom (Dynamic Thermal Optimization) 20 min. Station Rotation Station 1: Controller Challenge Station 2: Wireless Demo 5 min.

More information

Liebert PDX from 15 to 120 kw

Liebert PDX from 15 to 120 kw Liebert PDX from 5 to 0 kw The Thermal Management Solution for Small and Medium Data Centers Electronic Expansion Valve Efficiency Digital Scroll Partial Load icom TM Control TCO Optimization Integrated

More information

High Efficient Data Center Cooling

High Efficient Data Center Cooling Nordborg High Efficient Data Center Cooling Copenhagen Center on Energy Efficiency webinar 12. July 2017 Jörg Saar, Danfoss Cooling 1 Danfoss Cooling Contents 1. Short intro to Danfoss Cooling 2. Introduction

More information

Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors

Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors Aquaflair Air-cooled chillers and free-cooling chillers with double screw compressors BREC & BREF 350-1200kW 380V/3ph/60Hz - 460V/3ph/60Hz The all-in-one solution for your business need Combining cutting-edge

More information

DATA CENTER PRECISION COOLING: The Need For A Higher Level Of Service Expertise

DATA CENTER PRECISION COOLING: The Need For A Higher Level Of Service Expertise DATA CENTER PRECISION COOLING: The Need For A Higher Level Of Service Expertise TWO STAGE POWER DISTRIBUTION Executive Summary Today s data centers are changing rapidly, and it is more important than ever

More information

Welcome Association of Energy Engineers to the Microsoft Technology Center

Welcome Association of Energy Engineers to the Microsoft Technology Center Welcome Association of Energy Engineers to the Microsoft Technology Center Today s Agenda 10:00 10:30 What s new in data center energy efficiency planning and implementation? 10:30 11:00 ASHRAE data center

More information

MSYS 4480 AC Systems Winter 2015

MSYS 4480 AC Systems Winter 2015 MSYS 4480 AC Systems Winter 2015 Module 12: DATA CENTERS By Satwinder Singh 14/05/2015 1 Data Centers Data Centers are specialized environments that safeguard your company's most valuable equipment and

More information

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability Precision Cooling for Business-Critical Continuity TM Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability DATA CENTER SOLUTIONS For More Information:

More information

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Evaporative free air cooling technology Providing evaporative free air cooling solutions. Evaporative free air cooling technology Providing evaporative free air cooling solutions. Creating an effective workspace environment data centre free air cooling technology FreeCool - Evaporative Free

More information

Rack & Enclosure Systems

Rack & Enclosure Systems Knürr CoolTherm 4 35 KW Energy-efficient Server Cabinet Technology With Outstanding Benefits, To Minimize Energy Costs In The Data Center And Help Reduce Carbon Dioxide Emmisions Rack & Enclosure Systems

More information

GP SERIES Packaged Chillers

GP SERIES Packaged Chillers Blending Conveying Drying Process Cooling Heat Transfer Size Reduction GP SERIES Packaged Chillers Comprehensive Flexible Versatile Compact unitary designs available in a variety of configurations from

More information

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW The indirect evaporative free-cooling Air Handling Unit Flexible & Efficient 11 sizes from 30 kw up to 520 kw to fit your needs with maximum efficiency

More information

Liebert. PCW from 25 to 220 kw. Chilled Water Units Optimizing Data Center Efficiency

Liebert. PCW from 25 to 220 kw. Chilled Water Units Optimizing Data Center Efficiency Liebert PCW from 25 to 220 kw Chilled Water Units Optimizing Data Center Efficiency LIEBERT PCW from 25 to 220 kw Vertiv Vertiv designs, builds and services mission critical technologies that enable the

More information

CHAPTER 3 WATERCOOLED & CONDENSERLESS LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION. REMOTE CONDENSERS

CHAPTER 3 WATERCOOLED & CONDENSERLESS LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION. REMOTE CONDENSERS CHAPTER WATERCOOLED & CONDENSERLESS LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION. REMOTE CONDENSERS Unit Page CWW/K 8-9 CWW/K 8-P 0-P 0 - CWW/K 8 0 - MEA/K - MEA/K 8-P 0-P - RCA/K

More information

Technical Concept. Filter Fan Unit RETURN AIR. Type RA-AC Type RA-EC

Technical Concept. Filter Fan Unit RETURN AIR. Type RA-AC Type RA-EC Technical Concept Filter Fan Unit RETURN AIR Type RA-AC Type RA-EC Filter Fan Unit RETURN AIR Technical Concept Product Description Technical Data M+W Products Filter Fan Units RETURN AIR (FFU-RA) are

More information

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling Jeremiah Stikeleather Applications Engineer Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling While CRAH cooling has been

More information

IEC DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM

IEC DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM THE GLOBAL DATA CENTRE MARKET The data centre air conditioning market is expected to grow with a CAGR (compound annual growth rate) of about 12% in the next

More information

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise A White Paper from the Experts in Business-Critical Continuity Executive Summary Today s data centers are changing rapidly,

More information

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability Liebert AFC from 500 to 1450 kw The Adiabatic Freecooling Solution with Top-Tier Availability Liebert AFC, the Ideal Adiabatic Chilled Water Solution for Top-Tier Data Centers Emerson Network Power delivers

More information

New Design Strategies for Energy Saving. Intelligent free-cooling

New Design Strategies for Energy Saving. Intelligent free-cooling New Design Strategies for Energy Saving Intelligent free-cooling Intelligent New strategies for energy saving When designing mission critical systems for processing applications or highly technological

More information

Airedale International Air Conditioning Limited. Leeds Road, Rawdon Leeds, LS19 6JY, England

Airedale International Air Conditioning Limited. Leeds Road, Rawdon Leeds, LS19 6JY, England > For the latest information on our products please visit : www.airedale.com > Please refer to the technical manuals for more detailed information Your nearest Airedale distributor is: ISO 14001 EMS52086

More information

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP This case study will evaluate the feasibility of data center free cooling in the Middle East using indirect

More information

AIR COOLED CONDENSERS

AIR COOLED CONDENSERS AIR COOLED CONDENSERS NQAC Quiet Line HNSQAC NQAC Quiet Line kw () Highly efficient external rotor fan motors give optimum performance with low noise levels Multiple fans (on all except smallest models)

More information

Reducing Data Center Cooling Costs through Airflow Containment

Reducing Data Center Cooling Costs through Airflow Containment FEATURE Reducing Data Center Cooling Costs through Airflow Containment Implementing a containment solution in the data center costs much less than the alternatives of adding air handlers or other supplemental

More information

Optimizing Cooling Performance Of a Data Center

Optimizing Cooling Performance Of a Data Center ASHRAE www.ashrae.org. Used with permission from ASHRAE Journal. This article may not be copied nor distributed in either paper or digital form without ASHRAE s permission. For more information about ASHRAE,

More information

LCP Hybrid Efficient performance with heat pipe technology

LCP Hybrid Efficient performance with heat pipe technology LCP Hybrid Efficient performance with heat pipe technology 2 LCP Hybrid The whole is more than the sum of its parts The same is true of "Rittal The System." With this in mind, we have bundled our innovative

More information

CTC Low Temperature Process Chillers

CTC Low Temperature Process Chillers INNOVATE DESIGN APPLY CTC Low Temperature Process Chillers 5-500 Tons OUR BUSINESS IS COOLING YOURS TM When commercial grade isn t enough When it comes to process cooling, every application is unique in

More information

Retro-Commissioning Report

Retro-Commissioning Report 10 Retro-Commissioning Report Retro-Commissioning Retro-Commissioning is the process for identifying intrinsic operational and energy related issues in the facilities DDC system and providing a mechanism

More information

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability Liebert AFC from 500 to 1450 kw The Adiabatic Freecooling Solution with Top-Tier Availability Liebert AFC, the Ideal Adiabatic Chilled Water Solution for Top-Tier Data Centers Emerson Network Power delivers

More information

Cooling solutions for imaging systems. Reliable. Global. Customer-specific.

Cooling solutions for imaging systems. Reliable. Global. Customer-specific. Cooling solutions for imaging systems Reliable. Global. Customer-specific. KKT chillers. About KKT chillers KKT CHILLERS INNOVATION IS OUR STANDARD. Headquarters Kasendorf Germany The Brand The chiller

More information

Trailblazer AGZ-E air-cooled scroll chillers

Trailblazer AGZ-E air-cooled scroll chillers Trailblazer AGZ-E air-cooled scroll chillers 30 to 240 tons with Variable Speed Condenser Fan Technology The right features, the right value, right now Intelligent Equipment AGZ-E 30 to 161 RapidRestore

More information

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary Datacenter Efficiency Trends Cary Roberts Tellme, a Microsoft Subsidiary Power Slashing Tools P3 Kill-A-WATT Measures min, max, and instantaneous voltage and current draw Calculates power (watts), kilowatt

More information

IT Cooling Solutions. The Whole Range of. Data Center Cooling Solutions

IT Cooling Solutions. The Whole Range of. Data Center Cooling Solutions IT Cooling Solutions The Whole Range of Data Center Cooling Solutions DIRECT FREE COOLING ROOM COOLING HIGH DENSITY COOLING DATA CENTER COOLING INDIRECT FREE COOLING CHILLER UNITS AIR HANDLING UNITS MODULAR

More information

Precision Cooling for Business-Critical Continuity. Liebert CRV. Efficient Cooling For IT Equipment NEW. Extended Range Available From 10 To 50 kw

Precision Cooling for Business-Critical Continuity. Liebert CRV. Efficient Cooling For IT Equipment NEW. Extended Range Available From 10 To 50 kw Precision Cooling for Business-Critical Continuity Liebert CRV Efficient Cooling For IT Equipment NEW Extended Range Available From 10 To 50 kw Emerson Network Power, a division of Emerson, is a global

More information

MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers

MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers INNOVATE DESIGN APPLY www.motivaircorp.com MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers 60-500 Tons OUR BUSINESS IS COOLING YOURS TM When commercial grade isn t enough

More information

Filter Fan Unit LIGHT

Filter Fan Unit LIGHT Filter Fan Unit LIGHT Type LIGHT EC Technical Concept Technical Concept Filter Fan Unit LIGHT Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air to individual

More information

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc. Cooling on Demand - scalable and smart cooling solutions Marcus Edwards B.Sc. Schroff UK Limited Data Centre cooling what a waste of money! A 1MW data center needs 177,000,000 kwh in its lifetime of 10

More information

CLOSE CONTROL AIR CONDITIONERS DATA CENTERS DESIGN SIDE NOTES

CLOSE CONTROL AIR CONDITIONERS DATA CENTERS DESIGN SIDE NOTES CLOSE CONTROL AIR CONDITIONERS DATA CENTERS DESIGN SIDE NOTES DATA CENTER NEEDS A MINUTE IN THE LIFE OF INTERNET Evolving technology has created the necessity for ever greater exchange of data, increasing

More information

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems Knürr CoolAdd The universal retrofit solution against overheating in server racks Rack & Enclosure Systems Knürr CoolAdd When cold air is no longer enough! Data centers are subject to constant changes:

More information

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions Schneider Electric Cooling Portfolio Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions Data Center Cooling Agenda 1. How to size data center, server rooms, IDF rooms, etc in

More information

Liebert DSE Precision Cooling System Industry-best efficiency. Increased capacity. Ensured availability. EFFICIENCY. CAPACITY. AVAILABILITY.

Liebert DSE Precision Cooling System Industry-best efficiency. Increased capacity. Ensured availability. EFFICIENCY. CAPACITY. AVAILABILITY. Liebert DSE Precision Cooling System Industry-best efficiency. Increased capacity. Ensured availability. EFFICIENCY. CAPACITY. AVAILABILITY. Liebert DSE High-Efficiency Precision Cooling System Room-Based

More information

HIGH EFFICIENCY Central Chiller

HIGH EFFICIENCY Central Chiller Blending Conveying Drying Process Cooling Heat Transfer Size Reduction HIGH EFFICIENCY Central Chiller Energy Efficient Modular & Expandable Virtually Eliminate Downtime Available in 20-60 ton single units,

More information

Taking The Heat Off University of East Anglia Data Centre

Taking The Heat Off University of East Anglia Data Centre Taking The Heat Off University of East Anglia Data Centre University of East Anglia delivers data centre to match corporate green credentials The University of East Anglia (UEA) is one of the leading green

More information

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC Technical Concept Filter Fan Unit LIGHT Type LIGHT AC Type LIGHT EC Filter Fan Unit LIGHT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air

More information