Economizer Retrofi t Solutions
|
|
- Liliana Lamb
- 6 years ago
- Views:
Transcription
1 Economizer etrofi t Solutions ZIP ode patented technology will automatically recognize your climate zone and will set the high limit change over temperature providing automatic compliance. Plug and Play self-confi guring; if it s not plugged into the economizer, you won t have to worry about setting it up. Integrated onboard test sequence that ensures effortless compliance with alifornia Title 24 and verifi cation of proper operation. Fault Detection and Diagnostics (FDD) troubleshoot faults, initiates alarms, and reconfi gures for best operation. Easy-to-read automotive grade LD display delivers clear live status information, easy setup, changes, and operating history even in the brightest of days, and coldest of days. First and only economizer control that integrates onboard help for setup or troubleshooting. Applications The ZIP Economizer saves energy in buildings by using cool outside air as a means of cooling the indoor space. The ZIP can reduce HVA energy costs in cold and temperate climates while also improving indoor air quality. As energy codes change towards continual effi ciency, the ZIP Economizer satisfi es all the requirements. ZIP Economizer, with its plug and play modular design and patented ZIP ode setup, allows an easy way to ensure maximum energy savings and compliance with local energy codes.
2 ZIP Economizer Selection uide AND EON-ZIP BASE EON-ZIP-10K (Supply Air Sensor) TFB24-S up to 7.5 Tons LF24-S Tons NFB24-S Tons AFB24-S Tons DY BULB ENTHALPY EON-ZIP-10K O EON-ZIP-TH Note: Differential control requires one additional sensor for return air. Demand ontrol Ventilation (DV)* - EON-ZIP-EM + O2 sensor of your choice (0-2000PPM, 0-10VD). Preoccupancy Purge* - EON-ZIP-EM equires thermostat with purge setting and contacts. emote Damper Override - EON-ZIP-EM + SA24 Exhaust Fan - EON-ZIP-EM emote Alarm Notifi cation* - EON-ZIP-OM * May be required by local codes USA ANADA LATIN AMEIA/AIBBEAN
3 Honeywell W7210 to Belimo ZIP Economizer Honeywell W7210 Belimo ZIP Economizer W7210 WIE TEMINATION ZIP EONOMIZE WIE TEMINATION NA T T1 ST6008 O Timer P-P1 AUX2 Located on EON-ZIP-EM T-T1 Supply Air New Sensor So-So+ Outside Air- New Sensor Sr-Sr+ New Sensors + AT3 - AT1 24 VA HOT AT2 AT USA ANADA LATIN AMEIA/AIBBEAN 28
4 Honeywell W7212 to Belimo ZIP Economizer Honeywell W7212 Belimo ZIP Economizer W7212 WIE TEMINATION ZIP EONOMIZE WIE TEMINATION NA T T1 N P-P1 AUX2 Located on EON-ZIP-EM T-T1 Supply Air New Sensor So-So+ Outside Air- New Sensor New Sensors AQ-AQ1 02 +/- EF-EF1 EF* *EF, EFH1 provide 24 VA out. Interposing relay or contactor may be needed for exhaust fan control. Verify with TU wiring USA ANADA LATIN AMEIA/AIBBEAN
5 Honeywell W7459 to Belimo ZIP Economizer Honeywell W7459 Belimo ZIP Economizer W7459 WIE TEMINATION ZIP EONOMIZE WIE TEMINATION NA T T1 N P-P1 AUX2 Located on EON-ZIP-EM T-T1 Supply Air - New Sensor So-So+ Outside Air - New Sensor Sr-Sr+ New Sensors USA ANADA LATIN AMEIA/AIBBEAN 30
6 ZIP Economizer etrofit Kits and ZIP Packs BELIMO ETOFIT KITS Part Number Description omponents (# included in kit) EON-ZIP-AT Actuator Shaft Adapter allows easy retrofi t from Honeywell black box motors (M7XXX) to Belimo spring return actuator. Shaft, M4x8 Screws (4), Locking Nuts (4) EON-ZIP-LF1 Bracket with hole patterns to mount the LF Series actuator, horizontal or vertical position to meet space requirements. EON-ZIP-AT, Z-112, Screws EON-ZIP-TF1 Bracket with hole patterns to mount the TF Series actuator, horizontal or vertical position to meet space requirements. EON-ZIP-AT, Z-113, Spacers and Screws BELIMO ZIP PAK Part Number Description omponents (# included in kit) EON-ZIP-SDTF Single Dry Bulb with DV apability and TF Spring EON-ZIP-Base, EON-ZIP-EM, EON-ZIP-10K (2), TFB24-S, EON-ZIP-TF1 eturn Actuator (22 in-lbs) EON-ZIP-DDTF Differential Dry Bulb with DV apability and TF EON-ZIP-BASE, EON-ZIP-EM, EON-ZIP-10K (3), TFB24-S, EON-ZIP-TF1 Spring eturn Actuator (22 in-lbs) EON-ZIP-SETF Single Enthalpy with DV apability and TF Spring EON-ZIP-BASE, EON-ZIP-EM, EON-ZIP-10K, EON-ZIP-TH, TFB24-S, eturn Actuator (22 in-lbs) EON-ZIP-TF1 EON-ZIP-SDLF Single Dry Bulb with DV apability and LF Spring EON-ZIP-BASE, EON-ZIP-EM, EON-ZIP-10K (2), LF24-S US, EON-ZIP-LF1 eturn Actuator (35 in-lbs) EON-ZIP-DDLF Differential Dry Bulb with DV apability and LF EON-ZIP-BASE, EON-ZIP-EM, EON-ZIP-10K (3), LF24-S US, EON-ZIP-LF1 Spring eturn Actuator (35 in-lbs) EON-ZIP-SELF Single Enthalpy with DV apability and LF Spring EON-ZIP-BASE, EON-ZIP-EM, EON-ZIP-TH, EON-ZIP-10K, LF24-S US, eturn Actuator (35 in-lbs) EON-ZIP-LF1 HONEYWELL Y PAK BELIMO ZIP PAK Part Number Description Part Number Description Y7220A7215 Dry Bulb with black motor EON-ZIP-SDTF Single Dry Bulb with DV apability, 22 in-lbs YL7220A7503 Dry Bulb with non-communicating DA EON-ZIP-SDTF Single Dry Bulb with DV apability, 22 in-lbs YL7220AJ3103 Dry Bulb with communicating 27 in-lbs DA EON-ZIP-SDTF* Single Dry Bulb with DV apability, 22 in-lbs YL7220AJ3105 Dry Bulb with communicating 44 in-lbs DA EON-ZIP-SDLF* Single Dry Bulb with DV apability, 35 in-lbs Y7220S7215 Enthalpy with black motor EON-ZIP-SETF Single Enthalpy with DV apability, 22 in-lbs YL7220S7503 Enthalpy with non-communicating DA EON-ZIP-SETF Single Enthalpy with DV apability, 22 in-lbs YL7220SJ3103 Enthalpy with communicating 27 in-lbs DA EON-ZIP-SETF* Single Enthalpy with DV apability, 22 in-lbs YL7220SJ3105 Enthalpy with communicating 44 in-lbs DA EON-ZIP-SELF* Single Enthalpy with DV apability, 35 in-lbs *May be a lower torque cross, but acceptable for damper USA ANADA LATIN AMEIA/AIBBEAN
7 ZIP Economizer Wiring Diagrams Single Dry Bulb AT 1 AT 2 AT 3 AT ommon 2 + Hot 3 Y Input, 2 to 10V 5 U Output, 2 to 10V THEMOSTAT TU TEMINAL AT1 AT2 AT3 -S AT5 SAT+ SAT O O/B O AT+ AT- SAT- OAT+ OAT- SAT - OAT + EON-ZIP-10K Supply Air Temp TU Stage 1 Mechanical ooling ircuitry TU Stage 2 Mechanical ooling ircuitry AH+ AH- EON-ZIP-BASE OAH+ OAH- OAT - EON-ZIP-10K Outside Air Temp Differential Dry Bulb AT ommon THEMOSTAT O 52 O/B 51 TU TEMINAL O TU Stage 1 Mechanical ooling ircuitry TU Stage 2 Mechanical ooling ircuitry 1 2 AT1 AT2 AT3 AT5 SAT+ SAT- 1 2 AT+ AT- AH+ AH- OAT+ OAT- OAH+ OAH- EON-ZIP-BASE AT 2 AT 3 AT 5 SAT + SAT - OAT + OAT Hot 3 Y Input, 2 to 10V 5 U Output, 2 to 10V -S EON-ZIP-10K Supply Air Temp EON-ZIP-10K Outside Air Temp AT EON-ZIP-10K eturn Air Temp USA ANADA LATIN AMEIA/AIBBEAN 32
8 ZIP Economizer Wiring Diagrams Single Enthalpy AT 1 AT 2 AT 3 AT ommon 2 + Hot 3 Y Input, 2 to 10V 5 U Output, 2 to 10V THEMOSTAT TU TEMINAL AT1 AT2 AT3 -S AT5 SAT+ SAT O O/B O TU Stage 1 Mechanical ooling ircuitry TU Stage 2 Mechanical ooling ircuitry SAT- OAT+ OAT- OAH+ OAH- AT+ AT- AH+ AH- EON-ZIP-BASE SAT - OAT + OAT - OAH + OAH - EON-ZIP-10K Supply Air Temp T (+) T (-) H (+) H (-) 24 V () EON-ZIP-TH Outside Air Enthalpy 50 Differential Enthalpy AT 1 AT 2 AT 3 AT ommon 2 + Hot 3 Y Input, 2 to 10V 5 U Output, 2 to 10V THEMOSTAT TU TEMINAL AT1 AT2 AT3 -S AT5 SAT+ SAT + EON-ZIP-EM O O/B O TU Stage 1 Mechanical ooling ircuitry TU Stage 2 Mechanical ooling ircuitry AT+ T (+) AT- T (-) AH+ H (+) H (-) AH- 24 V () EON-ZIP-TH eturn Air Enthalpy AT+ AH+ SAT- OAT+ OAT- OAH+ OAH- AT- AH- EON-ZIP-BASE SAT - OAT + OAT - OAH + OAH ommon EON-ZIP-10K Supply Air Temp T (+) T (-) H (+) H (-) 24 V () EON-ZIP-TH Outside Air Enthalpy Purge ontact Thermostat 24 VA AUX1+ AUX1 + O2 + O Y Input, 0 to 10 VD 4-0 to 10 VD ommon Y Input, 2 to 10 VD to 10 VD + 4 SA24 SF24 AUX2 + AUX2 - AUX1 - AUX1 - O2 - AUX2 + IF AUX2 - EF EON-ZIP-EM O2 - O2 Sensor Indoor Fan Low Speed elay / VFD Enable Exhaust Fan ircuit USA ANADA LATIN AMEIA/AIBBEAN
ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN
ECON-ZIP-BASE ZIP Economizer Base Unit 24 VAC ± 20%, 50/60 Hz; Class 2 power source 4 VA Base Control (ECON-ZIP-BASE) 5.5 VA Base Control with Energy Module (ECON-ZIP-BASE + ECON-ZIP-EM) Power Consumption
More informationFast Route to Reliable Energy Savings ZIP Economizer
Fast Route to Reliable Energy Savings ZIP Economizer LCD Display Automotive quality, easy-to-read display allows easy verifi cation of set values and real time operating information Alarm Notification
More informationTHERMOSTATS & CONTROLLERS
DESCRIPTION The Belimo ZIP Economizer Series saves energy in buildings by using cool outside air as a means of cooling the indoor space. This application can drastically reduce HVAC energy costs while
More informationDownflow Economizers Z1ECON30 (98W09) ECONOMIZERS
Downflow s Z1EON30 (98W09) EONOMIZERS INSTALLATION INSTRUTIONS FOR EONOMIZERS USED WITH Z,ZG,ZH 036,048,060 UNITS Application The Z1EON30 (98W09) economizer is used with Z,ZG,ZH 036,048,060 units in downflow
More informationECON-ZIP-BASE. ZIP Economizer Base Module
ECON-ZIP-BASE ZIP Economizer Base Module You can mount the ZIP Economizer in any orientation; it is recommended that you mount it in a position that will allow full utilization of the LCD and key pad and
More informationTH8321R or TH8321WF with Economizer Fault
TH8321 or TH8321WF with Economizer Fault ADDENDUM TH8321 3. Field update file (for microsd card) currently available on the web portal. This feature added starting date code 1740. TH8321WF This feature
More informationINSTALLATION INSTRUCTIONS ECONOMIZERS WITH EXHAUST. For Use with Bard 3-1/2 through 6 Ton Wall Mount Air Conditioners and Heat Pumps
INSTALLATION INSTRUCTIONS ECONOMIZERS WITH EXHAUST Model EIFM-5C For Use with Bard 3-1/2 through 6 Ton Wall Mount Air Conditioners and Heat Pumps Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since
More informationINSTALLATION INSTRUCTIONS MBPEFY Series Mixing Box for Mitsubishi PEFY Series Units. Before Starting Installation Warning. Installation Instructions
Before Starting Installation Warning Shut power to unit prior to any work being done. Personal injury or death could result. Only qualified HVAC service personnel should install, troubleshoot, repair or
More informationINSTALLATION MANUAL FOR CARRIER/BRYANT 3-15 TON ECONOMIZERS 3-6 TON MODELS
INSTALLATION MANUAL FOR CARRIER/BRYANT 3-15 TON ECONOMIZERS 3-6 TON MODELS PART# 1022355 - STANDARD ECONOMIZER PART# 1022911 - RETROFIT ECONOMIZER (FOR UNITS WITH NO CTB) PART# 1023736 - ULTRA LOW LEAK
More informationECONOMIZERS. Z1ECON30B-1 ECONOMIZER (Cat No. 10Z29) INSTALLATION INSTRUCTIONS FOR ECONOMIZERS USED WITH ZC,ZG,ZH UNITS CAUTION WARNING
Litho U.S.A. 2014 ECONOMIZERS 3/2014 Supersedes: New Z1ECON30B-1 ECONOMIZER (Cat No. 10Z29) INSTALLATION INSTRUCTIONS FOR ECONOMIZERS USED WITH ZC,ZG,ZH 092-150 UNITS Application The Z1ECON30B-1 economizer
More informationEconomizer Controller Installation Guide
Economizer Controller Installation Guide PD 9/20/2013 - v 1.2 2 Table of Contents INPUTS... 3 OUTPUTS... 3 WHILE INSTALLING THIS CONTROLLER... 3 ACCESSORIES... 3 OPTIONAL ACCESSORIES... 3 INSTALLATION
More informationAdvanced RTU Controls Retrofit Solution
Advanced RTU ontrols Retrofit Solution TYPIAL 5-30 TON APPLIATION GUIDE This document contains information about the nationwide opportunity to potentially save substantial energy costs by upgrading existing
More informationEconomizer Control 2-1
HVAC Economizers 101 Section #2 Economizer Control Methods 2-1 Section #2 Economizer Control Methods Most Commonly Used Control Strategy Dry-bulb changeover Enthalpy changeover Differential dry bulb Differential
More informationInstallation Instructions
Installation Instructions Single Enthalpy Sensor Application AXB078ENT Differential Enthalpy Sensor Application (Part # AXB078ENT and DNENTDIF004A00) FOR ROOFTOP ECONOMIZERS EQUIPPED WITH HONEYWELL W7212
More informationJADE Economizer Module (MODEL W7220)
JADE Economizer Module (MODEL W70) INSTALLATION INSTRUCTIONS DCV (CO ) Sensor (C7): -0 Vdc control signal; minimum impedance >50k ohm. Outputs Actuator signal: -0 Vdc; minimum actuator impedance is k ohm;
More informationInstallation Instructions
Installation Instructions Single Enthalpy Sensor Application AXB078ENT Differential Enthalpy Sensor Application (Part # AXB078ENT and DNENTDIF004A00) FOR ROOFTOP ECONOMIZERS EQUIPPED WITH HONEYWELL W7212
More informationSE7600E Series. Installation Guide for Commerical HVAC Applications CONTENTS
SE7600E Series Installation Guide for ommerical HVA Applications ONTENTS Installation 2 Location 2 Installation 2 Terminal, Identification and Function 3 Screw terminal arrangement and wiring 3 Main outputs
More informationCustom Controller Installation Instructions
MODEL CUSTOM CONTROLLER HARDWARE CODE MAX ALLOWABLE AMBIENT TEMP: 70 C (158 F) THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: 1) THIS DEVICE MAY
More informationINSTALLATION INSTRUCTIONS ECODPRD3715 Series Vertical Economizer for York Predator 3-12½ Ton Units
Before Starting Installation Warning Shut power to unit prior to any work being done. Personal injury or death could result. Only qualified HVAC service personnel should install, troubleshoot, repair or
More informationINSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST
INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST MODEL WGSEIFM-5 For Use with Bard 3 through 5 Ton Step Capacity Wall Mount Air Conditioners with Gas Heat Bard Manufacturing Company, Inc. Bryan, Ohio
More informationField Installation Manual External Bolt-On Economizer for ComPac I Air Conditioners
Field Installation Manual External Bolt-On Economizer for ComPac I Air Conditioners Models: ComPac AVPA 42-48-60 The following instructions describe how to install the Marvair External Bolt-On Field Installed
More informationINSTALLATION INSTRUCTIONS ECOHPRS Series Horizontal Economizer for York PRESTIGE for ZX 04-07; ZY 04-06
Before Starting Installation Only qualified HVAC service personnel should install, troubleshoot, repair or service HVAC and related HVAC equipment. WARNING Electric shock hazard. Can cause injury or death.
More informationINSTALLATION INSTRUCTIONS ECOHAFF1860 Series Horizontal Economizer for York Affinity 3-5 Ton Units. Before Starting Installation Warning
INSTALLATION INSTRUCTIONS ECOHAFF1860 Series Horizontal Economizer for York Affinity 3-5 Ton Units NOTE: The Honeywell JADE controller requires only a Mixed Air Temperature sensor that has been factory
More informationWarning. Important. Always follow all local building electrical codes. PECCSUN3672DB46M PECCSUN3672EN46M
INSTALLATION INSTRUCTIONS PECCSUN672 Series Power Exhaust for York - 6 Ton Units Before Starting Installation Warning Severe injury can result from incorrect servicing. Only qualified HVAC service personnel
More informationIntroduction. What is the RTU Open controller?
RTU Open v5 CARRIER CORPORATION 2018 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-697-01 6/11/2018 Verify that you have the most current version of this document
More informationMinimum 360 in-lb torque - GK. Minimum 54 in-lb torque - NKQ. Minimum 101 lbf - AHQ. Electronic Fail-Safe Series Direct Coupled Actuators
Electronic Fail-Safe Series Direct oupled ctuators Minimum 360 in-lb torque - GK For damper areas up to 90 sq. ft* Minimum 54 in-lb torque - NKQ For damper areas up to 12 sq. ft* Minimum 101 lbf - HQ ll
More informationPackaged Rooftop Air Conditioning Units
PACKAGED ROOFTOP AIR CONDITIONING UNITS QUICK START-UP GUIDE New Release Form 100.50-SU3 (1207) 035-21972-200 TM Packaged Rooftop Air Conditioning Units YPAL 050 YPAL 051 YPAL 060 YPAL 061 DESIGN LEVEL
More informationPelican. Installation Guide Zoned Damper Control. Wireless Systems
Wireless Systems Installation Guide Zoned amper ontrol Wireless Systems, 655 ollier anyon d. Livermore, A 955 Phone: 888.5.090 Email: support@pelicanwireless.com Website: www.pelicanwireless.com Table
More informationPOL220 Series Economizer Controller
Document No. 125-1902 POL220 Series Economizer Controller Product Description The Economizer Controller allows the use of unconditioned outside air to cool a building. The Free Cooling air determination
More informationSE7600F Series. Installation Guide for RTU with Modulating Heat CONTENTS
SE7600F Series Installation Guide for RTU with Modulating Heat ONTENTS Installation 2 Location 2 Installation 2 Model hart 3 Network ready 3 Terminal, Identification and Function 3 Screw terminal arrangement
More informationTransformative Wave Technologies Kent, Washington
Transformative Wave Technologies Kent, Washington www.transformativewave.com manufacturers of the North America s Leading Energy Efficiency Solution for Constant Volume HVAC Systems The CATALYST converts
More informationEconomizer Fault Detection and Diagnostics (FDD) for Built-Up Air Handlers Draft Report
Economizer Fault Detection and Diagnostics (FDD) for Built-Up Air Handlers Draft Report Draft Code Language Last Updated: March 2017 1. INTRODUCTION The California Statewide Utility Codes and Standards
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS EIFM CONTROL REPLACEMENT KIT 8620-239 For Use with 3-1/2 Through 6 Ton Wall Mount Air Conditioners and Heat Pumps with EIFM-5* Economizers or "E" Vent Option Bard Manufacturing
More informationseal leak & temperature relays
seal leak & temperature relays 2014 catalog a of products 800.238.7474 www.macromatic.com sales@macromatic.com 1 SINGLE & DUAL CHANNEL SFP Series SFP Series Pump Seal Failure Relays are designed to monitor
More informationTF243 Series Digital Thermostat Fan Coil Unit Control
TF243 Series Digital Thermostat Fan Coil Unit Control Features SPECIFICATION DATA General The TF243 series digital thermostat is designed for 3-speed fan and modulating valve control in a fan coil system,
More informationIndoor Unit Controller (IUC) Quick Reference and Fault Diagnosis
Indoor Unit Controller (IUC) Quick Reference and Fault Diagnosis Date: 1 November 2015 Issue: 1 IUC software version: 1.5 Index 1. Introduction... 2 2. List of units with IUC... 2 3. Features and functions...
More informationSmart Equipment Controls (SEC)
Smart Equipment Controls (SEC) Product Bulletin SE-SPU1001-0, SE-SPU1002-0, SE-SPU1011-0, SE-SPU1011-0, SE-SPU1012-0, SE-SPU1004-0, SE-FDD1001-0, SE-ECO1001-0, SE-COM1001-0 Code No. LIT-12011934 Issued
More informationWHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net
Digi-RTU WHAT IS THE DIGI-RTU The Digi-RTU is a Heating, Ventilation, and Air Conditioning (HVAC) rooftop unit control kit that is both a demand management and energy usage device. It is designed to improve
More informationUSER'S GUIDE BARD-LINK TM LC /LC SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER & TEC-EYE HAND-HELD DIAGNOSTIC TOOL
USER'S GUIDE BARD-LINK TM LC1000-100/LC1500-100 SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER & TEC-EYE HAND-HELD DIAGNOSTIC TOOL Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead,
More informationINSTALLER'S GUIDE ECON-IN-30B 18-HE60D83-3. Accessory Economizer Downflow
INSTALLER'S GUIDE Customer Property Contains wiring, service, and operation information. Please retain. Models: BAYECON061B BAYECON062B BAYECON063B BAYECON075A Used With: YC,TCD103C,120B,150C & WCD120B,
More informationNKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V
NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V orque min. 54 in-lb for control damper surfaces up to 12 sq ft. Application For proportional modulation of dampers in HVAC systems.
More informationNKQB24-1, NKQX24-1 On/Off, Electronic Fail-Safe, Direct Coupled, 24V
NKQB24-1, NKQX24-1 On/Off, Electronic Fail-Safe, Direct Coupled, 24V orque min. 54 in-lb for control damper surfaces up to 12 sq ft. Application For on/off, fail-safe control of dampers in HVAC systems.
More informationDUKE UNIVERSITY DESIGN & CONSTRUCTION STANDARDS
1 25 95 00 Integrated Automation Control Sequences for HVAC GENERAL The HVAC operational sequences in this guideline are commonly used by Duke University. They are being provided as a preferred design
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS ECODLXS/ ECODLXL. Economizer Installation Instructions ECONOMIZER TOP PANEL
ACCESSORY KIT INSTALLATION INSTRUCTIONS ECODLXS/ ECODLXL Economizer Installation Instructions NOTE: The Honeywell JADE controller requires only a Mixed Air Temperature sensor that has been factory installed
More informationMODELS DSH/DSV R-410A AIR SIDE ECONOMIZER KIT
MODELS DSH/DSV R-410A AIR SIDE ECONOMIZER KIT Form 145.11-IOM1 (412) AIR SIDE ECONOMIZER FOR DSH AND DSV R-410A AIR COOLED AIR CONDITIONING UNITS INSTALLATION INSTRUCTIONS B Style IMPORTANT! READ BEFORE
More informationEnergy Efficiency Retrofit Technologies for RTUs
Energy Efficiency Retrofit Technologies for RTUs POTENTIAL RTU RETROFITS Retrofits proven to increase the energy efficiency and reduce operating costs Stated Goals of RTU Retrofit development (DOE): Optimize
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationMillennium Simplicity Elite Parameter Points and Quirks
Millennium Simplicity Elite Parameter Points and Quirks How to access, view and change parameter settings Program Button Test Reset UP Alarms Change Data Address Down 1. Push the Program button once. The
More informationinstallation quick guide integrated access control & environmental monitoring
installation quick guide integrated access control & environmental monitoring Introduction This Installation Quick Guide is suitable for standard wallmountable AX300 controllers. Illustrative technical
More informationTechnical data sheet. Technical data
echnical data sheet LMQ4A Damper actuator for adjusting air control dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx 8 m orque 4 Nm Nominal
More informationMODELS DSH/DSV R-410A AIR SIDE ECONOMIZER KIT
MODELS DSH/DSV R-410A AIR SIDE ECONOMIZER KIT Form 145.11-IOM1 (412) AIR SIDE ECONOMIZER FOR DSH AND DSV R-410A AIR COOLED AIR CONDITIONING UNITS INSTALLATION INSTRUCTIONS B Style IMPORTANT! READ BEFORE
More informationNON-PROGRAMMABLE OFF DELAY, SINGLE SHOT
time delay relays plug-in NON-PROGRAMMABLE OFF DELAY, SINGLE SHOT & WATCHDOG 8 Pin SPDT Versions TR-5 Series These are 8 pin 10A SPDT versions of our standard 11 pin DPDT products Onboard & remote adjustable
More informationNSV-SY Battery Back-Up System
70677-00001B NSV-SY Battery Back-Up System Provides Fail-Safe Operation for SY Series Industrial Electric Actuators, SY1 thru SY12. Field Selectable Fail Direction Readily Available Sealed Lead-Acid Battery
More information9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)
echnical data sheet EF24A- Communicative spring return actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx.
More information4 Wiring Brochure Wiring and
- Wiring Brochure ing Expansion Module 444 W 444 12/08 1 Information Brochure hoose controls to match application Application Brochure Design your mechanical applications 2 3 ough-in Wiring ough-in 4 Wiring
More informationFunctional data Factory settings Variable Setting Torque Inhibiting torque
echnical data sheet GK4A-MF Parameterisable SuperCap rotary actuator with emergency setting function and extended functionalities for adjusting air dampers in ventilation and air-conditioning systems for
More informationCOND. A ENABLE RELAY CONTACT COOLA ENABLE 24 VAC. RATING IS 1 AMP COND. B ENABLE COOL B ENABLE.
Factory Packaged Controls Coil Products Two Head Pressure Module Orion No.:OE370-23-HP2C 1 2 3 4 www.aaon.com www.orioncontrols.com Circuit A1 TRANSDUCER #1 Circuit A2 TRANSDUCER #2 Circuit B1 TRANSDUCER
More informationApplication Engineering
Application Engineering Application Engineering Commercial Comfort Controller (543-0175-00) Installation Guide May 2012 Contents Mounting... 1 Connections and Wiring... 1 Wiring Considerations... 1 Input
More informationINSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST
INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST Model: JIFM-1A For Use with Bard 1 Ton Wall Mount Air Conditioner Bard Manufacturing Company, Inc. Bryan, Ohio 43506 www.bardhvac.com Manual : 2100-616A
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Full Flow Low Leakage Economizers with Exhaust for Building Applications Models: ECON-WD- & ECON-WD- Factory-Installed Vent Option with Enthalpy Outdoor Control (Field-Installed
More informationStarzone 4000 Master Control Panel Figure 2.1 Master Control Panel
Starzone 4000 Master Control Panel Figure 2.1 Master Control Panel The heart of the Starzone 4000 system is the Starzone Master controller (SZM-4000). Each AHU that is to be zoned will have its own SZM-4000
More informationRepair Parts List DRYER MODEL NUMBER DE712. When requesting service or ordering parts, always provide the following information:
Repair Parts List DRYER MODEL NUMBER DE712 When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description 2005 Maytag
More informationRTULink Monitoring and Control Installation, Operation, and Maintenance Manual
RTULink Monitoring and Control Installation, Operation, and Maintenance Manual RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and if found, report it immediately
More informationA CLOSER LOOK. Electronic Fail-Safe Series Direct Coupled Actuators. The Belimo Difference. Brushless DC Motor for Added Accuracy and Controllability
Electronic Fail-Safe Series Direct Coupled Actuators A CLOSER LOOK Brushless DC Motor for Added Accuracy and Controllability Cut Labor Costs with Simple Direct Coupling Self-Centers on 1.05" or 3/4" with
More informationOPERATION INSTRUCTIONS
2018 Lennox Industries Inc. Dallas, Texas, USA OPERATION INSTRUCTIONS V0STAT52 Wireless Indoor Unit Controller CONTROLS 507459-04 05/2018 This manual must be left with the owner for future reference. IMPORTANT
More informationAdditional features include: Slab Minimum and Slab Maximum Temperature Control. Test Sequence to Ensure Proper Component Operation
LR 58233 E150539 LR 58233 E150539 70 70 WWSD - Data Brochure Zone ontrol 369 D 369 10/00 The Zone ontrol 369 is designed to control the temperature in up to six heating zones using Room Temperature Units
More informationLab and Central Plant Controller
Metasys Network Sales Resource Manual 635 Application Specific Controllers Section Product Bulletin Issue Date 0290 Lab and Central Plant Controller The Metasys Lab and Central Plant (LCP) Controller is
More informationNew 30AA and 31AA Electronic Motor Protection Modules. Application Bulletin 128
New 30AA and 31AA Electronic Motor Protection Modules Application Bulletin 128 Application Bulletin Number: 128 Release EN: D09910 Date: 4/19/96 Revision EN: Z27301 Date: 10/2/15 Subject: New 30AA and
More informationNON-PROGRAMMABLE ON DELAY, INTERVAL, TRUE OFF DELAY & FLASHER
time delay relays plug-in NON-PROGRAMMABLE ON DELAY, INTERVAL, TRUE OFF DELAY & FLASHER Onboard & remote adjustable or fi xed time delays from 0.05 seconds to 2 hours Uses industry-standard 8 pin octal
More informationCommercial Controls. Advanced control for saving time and money
L Connection NetWork Commercial Controls Advanced control for saving time and money The efficient way to control hvac and building operations L Connection Network at a glance: Controls a wide range of
More informationYORK HVAC PRODUCT GUIDE
YORK HVAC PRODUCT GUIDE PD 2/4/2014 v 1.3 Pricing shown is in U.S. Dollars Pricing subject to change without notice 1 Table of Contents Mated ERVs...2 OA Hood Economizer Systems...3 Hood and Duct Part
More informationSRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s
SRQ24A Rotary actuator for ball valves orque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s echnical data Electrical data Nominal voltage AC 24V, 50/60Hz / DC 24V Nominal voltage range
More informationOpenAir Electronic Damper Actuator GDE/GLB Rotary Non-spring Return
OpenAir Electronic Damper Actuator GDE/GLB Rotary Non-spring Return Document No. 9-67 EA678R a b e d c f a. Actuator b. Position indicator c. Mounting bracket d. Mounting screws e. 4 mm hex key f. Shaft
More informationTracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001
Tracer Controls Tracer MP.501 Controller June 2001 BAS-PRC008-EN Introduction The Tracer MP.501 controller is a configurable, multi-purpose controller used to provide direct-digital control for heating,
More informationTRACE 700. Slide 1. Today, we will be talking about Airside Economizers in TRACE 700. Slide 2
Slide 1 TRACE 700 Today, we will be talking about Airside Economizers in TRACE 700. Airside Economizers Slide 2 Learning Objectives Define airside economizing Discuss different airside economizer types
More informationOptions Overview. February 6, Ben Newell
Options Overview February 6, 2018 Ben Newell CERV2 Configuration Unitary All-in-One System Heat pump and dampers Fans same ECM fans as current CERV Fresh air and return filters (nom. 10 x20 ) Integrated
More informationSEZ7656R1045B / SEZ7656H1045B
SEZ7656R1045B / SEZ7656H1045B Installation Guide f BACnet MS-TP RTU / HP Room Controllers F Commercial Zoning Systems CONTENTS Installation 2 Location 2 Installation 2 BACnet System Overview 3 Terminal,
More informationDual Digital Module Technical Guide
Factory Packaged Controls Coil Products Dual Digital Module Table of Contents OVERVIEW... 3 INSTALLATION AND WIRING... 4 Environmental Requirements...4 Mounting...4 Power Supply and Communications...4
More informationINDOOR UNIT CONTROLLER (IUC) Operation Manual
INDOOR UNIT CONTROLLER (IUC) Operation Manual Date: 9 June 2015 Issue: 4 Note: Information in this document applies to IUC controllers programmed with software version 1.5. Page 1 of 11 Contents 1. Introduction...
More informationBuilt-in features Built-in simplicity Built for fans & pumps
GE Built-in features Built-in simplicity Built for fans & pumps AF-600 FP Fan & Pump Drives imagination at work Built for variable torque Specifically designed for fan and pump applications, the AF-600
More informationTracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN
Tracer Controls Tracer Unitary Controller 7 April 2003 BAS-PRC012-EN Introduction The Tracer unitary controller provides digital control that is similar to that of a wall thermostat. It supports the following
More informationETM-2050/ETM-2051 Service Manual
Introduction Novar s Electronic Thermostat Modules (ETMs) are intelligent control modules that provide local, direct digital control of unitary, packaged, staged HVAC systems. This document: Describes
More informationPower consumption In operation At rest For wire sizing
echnical data sheet Modulating damper actuator for adjusting air control dampers in ventilation and airconditioning systems for building services installations For air dampers up to approx 08 m orque Nm
More informationHVAC unit. Spacerfor. ILL. 3 1" filter. Screw
MicroMetl's 0637 economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions completely and carefully before beginning installation For
More informationVAVBOX Controller Technical Guide
www.wattmaster.com Technical Guide Table Of Contents Controller Overview... 3 Features... 3 Controller Inputs and Outputs... 5 General... 5 Analog Inputs:... 5 Other Controller Connections... 5 Optional
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL INTEGRATED PROGRAMMABLE CONTROLS
INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR EV450, ALL HE, LE AND RD UNITS Carel c.pco Mini Carel c.pcoe Expansion Board WWW.RENEWAIRE.COM IMPORTANT SAFETY INFORMATION WARNING Arc flash and electric
More informationWhat Piggyback is all About. Overview of the Electrical Wiring Options for Piggyback Mounting
What Piggyback is all About Terminology Piggyback PGB I PGB II Description Increase in torque achieved by simultaneously controlling and physically coupling two or more actuators on one shaft or multiple
More informations Spring return C / max C
echnical data sheet SF4A actuator for WORKS with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 4 m orque 0 Nm Nominal
More informationRetro-Commissioning Report
10 Retro-Commissioning Report Retro-Commissioning Retro-Commissioning is the process for identifying intrinsic operational and energy related issues in the facilities DDC system and providing a mechanism
More informationPower consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor
echnical data sheet GK24A-SR Modulating SuperCap rotary actuator with emergency setting function and extended functionalities for adjusting air dampers in ventilation and air-conditioning systems for building
More informationL Connection Network Control System For Energence Rooftop Units
C O N T R O L S P R O D U C T S P E C I F I C AT I O N S L Connection Network Control System For Energence Rooftop Units Bulletin No. 210594 October 2011 Supersedes December 2010 Commercial Building Automation
More informationOverview of types. Technical data
echnical data sheet SH2A-MF.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control
More informationElectric Actuators with Process Controllers
Electric Actuators with Process Controllers TROVIS 5724-8 (without fail-safe action) TROVIS 5725-8 (with fail-safe action) For heating and cooling applications Application Electric actuators with integrated
More informationRooftop Unit Optimization Offering Frequently Asked Questions and Updates Released April 1, 2013
1 South Pinckney, Suite 340 Madison, WI 53703 phone: 800.762.7077 fax: 608.230.7035 focusinfo@focusonenergy.com www.focusonenergy.com Rooftop Unit Optimization Offering Frequently Asked Questions and Updates
More informationMODBUS AND BACNET COMMUNICATION INSTRUCTIONS
FB-MODB_100161012_2000020084_Rev L MODBUS AND BACNET COMMUNICATION INSTRUCTIONS Crest Models: 751-6000 WARNING This manual must only be used by a qualified heating installer / service technician. Read
More informationExactLogic BACnet Communicating Pressure Dependent VAV Damper Control with Heat EXL01820 Sequence Datasheet
ExactLogic BACnet Communicating Pressure Dependent VAV Damper Control with Heat EXL01820 Sequence Datasheet DataSheet ev 1.12.307/4.0 June 14, 2018 Operating Sequence Standard Occupied During normal occupied
More informationIN STAL LA TION IN STRUC TION
FORM# 654B-0511 (654B-0808) I - SHIP PING AND PACK ING LIST Check for correct number of parts. See list below. Package 1 of 1 contains: 1 - Economizer Assembly (Discharge Air Sensor Included) 1 - Barometric
More informationActuating Terminal Equipment Controller (ATEC) VAV with Reheat. Start-up Procedures Building Technologies Restricted
Actuating Terminal Equipment Controller (ATEC) VAV with Reheat Start-up Procedures 140-1202 Building Technologies 2015-05-06 Restricted Table of Contents... 4 Verifying Power to the Controller... 4 Setting
More informationWHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net
WHAT IS THE DIGI-RTU The Digi-RTU is a Heating, Ventilation, and Air Conditioning (HVAC) rooftop unit control kit that is both a demand management and energy usage device. It is designed to improve the