1 B O N N E V I L L E A D M I N I S T R A T I O N B O N N E V I L L E P O W E R A D M I N I S T R A T I O N NERC Monitoring and Situational Awareness Conference Bonneville Power Administration Self-Monitoring: Network and System Operations Center (NSOC) Title Sub Title September 30,

2 Today s Topics Agency Overview; NSOC: Definition, Purpose and Services: Monitoring system health; Monitoring network and telecommunication health; and Monitoring cyber security. Benefits of an NSOC; and Challenges of Developing an NSOC. 2

3 Agency Overview Bonneville Power Administration (BPA) is a federal agency established in 1937; BPA is self-funded and recovers all Agency costs through rates for wholesale power sales and transmission services; and BPA s service territory spans 15,000 transmission miles in the Pacific Northwest and consists of Oregon, Washington, Idaho, and parts of California, Montana, Nevada, and Utah; BPA is registered with NERC for the following functions: BA, TOP, TO, TP, TSP, PC, PSE, and RP 3

4 Agency Overview, continued BPA: Assures resource adequacy to meet the Pacific Northwest region s firm power requirements; Markets, but does not own, wholesale power from federal dams and acquired from non-federal generation; Builds, owns, operates and maintains a high-voltage transmission system to integrate and deliver power from federal and non-federal generation to regional customers in the Pacific Northwest and between the Northwest and the Southwest; and Protects and enhances fish and wildlife in the Columbia River basin. 4

5 BPA Statistics BPA Statistics Balancing Authority (BA) Installed Generation 32,157 MW Amount BA Peak Load, Feb. 6, 2014 Average Load, Jan. 1 May 27, 2015 Total Exports 2014 Total Imports 2014 Interchange Points with 17 BAs ~247 Transmission Customers ~500 10,643 MW 6,200 MW 83,267,202 MWh 25,221,117 MWh Operates and manages the federal transmission system (over 15,000 circuit miles over 11,000 circuit miles 230kV or higher, over 260 substations). 5

6 Agency Overview Power Services Transmission Services 6

7 Agency Overview BPA markets electric power from 31 federal Power Services dams, the Columbia Generating Station Nuclear Plant, and several small nonfederal power plants: About 80 percent of the power BPA sells is hydroelectric; and BPA accounts for about 30 percent of the electric power consumed within the region. 7

8 Agency Overview Power Services Transmission Services 8

9 Agency Overview Transmission System Operating voltage Circuit miles 1,000 kv * 500 kv... 4, kv kv kv.. 5, kv kv kv.. 3,509 below 115 kv Total 15,156 Transmission Services BPA SUBSTATIONS. 259 *BPA s portion of the PNW/PSW direct-current intertie. The total length of this line from The Dalles, Ore., to Los Angeles, Calif., is 846 miles. BPA s transmission system contains more than 15,000 miles of high voltage lines. About 75 percent of the high-voltage grid in the Pacific Northwest. 9

10 Transmission Services System Operations System Operations is responsible for the safe, reliable, open access operation and dispatch of the high voltage transmission system and interconnected generation. This is accomplished through the operation and management of two independent control centers. These two control centers, one in Vancouver and one in Spokane, are connected via BPA-owned and operated, fully redundant, telecommunication systems comprised of both fiber optic and radio systems, with the same BPA-owned communication systems also used to communicate to most remote sites. Both centers are staffed and operating on a 24/7 basis. During normal operations, each control center has access to all transmission data, most through independent communications, but responds to only that portion currently under their jurisdiction. Either the locally hosted systems or those of the alternate control center can be used. During emergency operations, jurisdictions can be reassigned between control centers based on communication connectivity or a single control center can assume jurisdiction of the entire BPA footprint. 10

11 Network and System Operation Center Provides continuous Network and System monitoring, incident response, IT support, remedial action, and incident coordination. 11

12 What Is an NSOC? The N-SOC is a combination of a Network Operation Center (NOC) and a Systems Operation Center (SOC); The N-SOC support identifies problems as a result of alerts processed by monitoring tools, customer complaints, or other actionable information; and The N-SOC support group is staffed by people with broad technical skills, so they can address complex operational issues with little or no assistance. 12

13 NSOC Services Provide single point of contact for work affecting the control center computers, software, networks, and building systems; Perform on-site system response, mitigation, and recovery; Provide immediate IT/OT response, support, and maintenance; Support the coordination of work in the Control Center s data center to ensure no concurrent outages of critical systems; Remote OTDR system allows for immediate response; Personnel tracking at remote sites; Provide damage assessments and begin system recovery immediately after a critical failure; continued 13

14 NSOC Services, continued Advise dispatch on system availability, path degradation, and schedule work impacts to the BES; Perform detection and reporting of potential cyber instances; and Centralized log collection correlation and monitoring. 14

15 NSOC 15

16 System Health: Monitoring Infrastructure status and functionality; Functionality alarming and response; Stale-data detection; Performance utilization; and Availability metrics. 16

17 SYSTEM HEALTH Infrastructure Status and Functionality SCADA alarms for Control Center infrastructure status Infrastructure status: HVAC, UPS, Generator, etc., status; and Rack power availability. Infrastructure functionality: Server status and health indications: Drive space; CPU utilization; and Power supply health. Server status and functionality 17

18 SYSTEM HEALTH Functionality Alarming and Response EMS System Alarm Screen Procedure Storage Functionality alarming: EMS systems provide alarming related to the function of the system; and Alarming provided for metering and curtailment utilities along with various systems used by our dispatchers and schedulers. Response: Document store contains over 900 procedures for immediate response: Documents searchable and tagged or manually grabbed from store. 18

19 SYSTEM HEALTH Stale-Data Detection SCADA Datamon alarms: Watches various indications on data from RTUs and ICCP; and Alarms with data has not changed in a predetermined time-frame. SCADA alarm for stale data Displays ICCP Data status; and Graphical alert if a single dataset has bad data. ICCP Dataset Status 19

20 Network and Telecom Health: Monitoring Remote communication and environmental monitoring: SCADA RTU status; Fiber monitoring; Microwave monitoring; Telemetry data Network availability: Between Control Centers; Between primary and secondary systems; and Between ICCP and points. Network utilization; and Network status mapping. 20

21 NETWORK AND TELECOM HEALTH Remote Site Communication and Environmental Monitoring Communication Alarming: Communication status; Fiber status; and Microwave status. Environmental: Door alarms; HVAC status; and Battery and generator status. Telecommunication Alarming 21

22 NETWORK AND TELECOM HEALTH Network Availability and Utilization ICCP Network availability and utilization Network availability: Graphical representation of control center networks and services. Network utilization: Graphical path utilization alerting. 22

23 Monitoring; Response; and Security controls testing. Cyber Security 23

24 CYBER SECURITY Monitoring Malware detection; Intrusion detection; Login failures; Account changes and creation of elevated accounts; Predictive firewall analytics; and Security controls testing on control systems. 24

25 CYBER SECURITY Response Cyber Security Response: Centralized log collected for systems with-in the control center; Tiered Cyber Security approach: Functional groups maintain cyber response and visibility; and Dedicated Cyber Security and Analysis Center helps identify APTs and performs forensics. Splunk Alert Manager 25

26 CYBER SECURITY Security Controls Testing Security controls testing overview: Security controls testing: Approximately 460 security controls locked, enforced, and tested to ensure security; Security controls exemption by exception and justification only, other mitigations may be enforced; and Servers and workstations with-in the Control Centers monitored. 26

27 Benefits; and Challenges to Development. NSOC Final Comments 27

28 NSOC Benefits The benefits of the N-SOC include improved reliability, shorter Mean-Time-To-Recovery (MTTR); Centralized tools requires a lower lifetime investment and increases human resources utilization and operational efficiencies; and The N-SOC operates around-the-clock and is physically located next to our Dispatch customers, making it an unmatched option at an ideal location. 28

29 NSOC Challenges to Development Implementing the N-SOC required a large investment of time and resources. A significant investment in equipment, facilities infrastructure, staff hiring and employee training was required. Time was required to develop the skill sets needed to manage the new technologies and tools, cross-train, and develop equipment maintenance programs. To enable the N-SOC functions, new network, hardware and software infrastructure were needed. Additional communication lines and video conferencing equipment, were required for full N-SOC functionality. 29

30 Questions? NERC Monitoring and Situational Awareness Conference Self-Monitoring: Network and System Operations Center (NSOC) 30

B O N N E V I L L E A D M I N I S T R A T I O N B O N N E V I L L E P O W E R A D M I N I S T R A T I O N

B O N N E V I L L E A D M I N I S T R A T I O N B O N N E V I L L E P O W E R A D M I N I S T R A T I O N B O N N E V I L L E A D M I N I S T R A T I O N B O N N E V I L L E P O W E R A D M I N I S T R A T I O N NERC Monitoring and Situational Awareness Conference Bonneville Power Administration Loss of EMS:

More information

Technology Innovation Delivering Value to BPA Organized, Disciplined, Focused

Technology Innovation Delivering Value to BPA Organized, Disciplined, Focused B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Technology Innovation Delivering Value to BPA Organized, Disciplined, Focused Keeping the Lights on for the Long Term The Basics Bonneville Power

More information

WEI Conference SDG&E TCRI Project April 25, 2018 Mark Fowler, CISSP

WEI Conference SDG&E TCRI Project April 25, 2018 Mark Fowler, CISSP WEI Conference SDG&E TCRI Project April 25, 2018 Mark Fowler, CISSP San Diego Gas & Electric Subsidiary of Sempra Energy 4100 Full-Time Employees Regulated public utility Providing clean, safe & reliable

More information

Wide-Area Reliability Monitoring and Visualization Tools

Wide-Area Reliability Monitoring and Visualization Tools OE Visualization and Controls Peer Review Wide-Area Reliability Monitoring and Visualization Tools Carlos Martinez CERTS - Electric Power Group 21 October 2008 Washington, D.C. Presentation Outline Research

More information

SPP RTO Compliance Forum Western Area Power Administration March 11, 2015

SPP RTO Compliance Forum Western Area Power Administration March 11, 2015 SPP RTO Compliance Forum Western Area Power Administration March 11, 2015 Mark Buchholz WAPA Upper Great Plains Region Compliance Manager What is Western? One of four Power Marketing Administration within

More information

CIP V5 Implementation Study SMUD s Experience

CIP V5 Implementation Study SMUD s Experience CIP V5 Implementation Study SMUD s Experience Tim Kelley October 16, 2014 Powering forward. Together. SMUD Fast Facts General Information SMUD employs approximately 2,000 individuals Service area of 900

More information

Wide Area Measurements & Control Systems

Wide Area Measurements & Control Systems The 8 th Electric Power Control Centers Workshop June 5-8, 2005, Les Diablerets, Switzerland Wide Area Measurements & Control Systems NERC Security Coordinators and Interregional Security Network Nodes

More information

Interconnection and Transmission

Interconnection and Transmission Interconnection and Transmission Gary L. Brown, P.E. Director of Energy Development Gary@ZGlobal.biz 916-985-9461 Kevin Coffee Energy Management Committee Meeting Irvine, California August 26, 2015 Interconnection

More information

Chief Executive Officer. Pacific Northwest Utilities Conference Committee Portland, Oregon March 8, 2013

Chief Executive Officer. Pacific Northwest Utilities Conference Committee Portland, Oregon March 8, 2013 Mark W. Maher Chief Executive Officer Pacific Northwest Utilities Conference Committee Portland, Oregon March 8, 2013 Agenda WECC Overview WECC Strategic Planning Initiative Western Interconnection Synchrophasor

More information

Revised Generation Interconnection Impact Study Report. For. Queue Position 31 ( Interconnection Customer )

Revised Generation Interconnection Impact Study Report. For. Queue Position 31 ( Interconnection Customer ) Revised Generation Interconnection Impact Study Report For Queue Position 31 ( Interconnection Customer ) September 22, 2004 1 Generation Interconnection System Impact Study Report I. Revision of Original

More information

2 nd Annual NERC Monitoring and Situational Awareness Conference: FPL s Operational Technology Center

2 nd Annual NERC Monitoring and Situational Awareness Conference: FPL s Operational Technology Center 2 nd Annual NERC Monitoring and Situational Awareness Conference: FPL s Operational Technology Center Ed Batalla Director of Grid Control Systems Florida Power & Light Company Sept. 24, 2014 Florida Power

More information

Strategy Consulting Digital Technology Operations. Transmission Distribution SCADA Separation 2017 EMMOS Conference

Strategy Consulting Digital Technology Operations. Transmission Distribution SCADA Separation 2017 EMMOS Conference Strategy Consulting Digital Technology Operations Transmission Distribution SCADA Separation 2017 EMMOS Conference SCADA for Electric Utility Operations The SCADA platform is at the heart of Electric Utility

More information

October 05, ECE 421 Session 12. Utility SCADA and Automation. Presented by: Chris Dyer

October 05, ECE 421 Session 12. Utility SCADA and Automation. Presented by: Chris Dyer ECE 421 Session 12 October 05, 2017 Utility SCADA and Automation Presented by: Chris Dyer Utility SCADA & Automation Chris Dyer, P.E. BSEE University of Idaho, 1997 SCADA & Automation Engineer POWER Engineers,

More information

November 29, ECE 421 Session 28. Utility SCADA and Automation. Presented by: Chris Dyer

November 29, ECE 421 Session 28. Utility SCADA and Automation. Presented by: Chris Dyer ECE 421 Session 28 November 29, 2018 Utility SCADA and Automation Presented by: Chris Dyer Utility SCADA & Automation Chris Dyer, P.E. BSEE University of Idaho, 1997 SCADA & Automation Engineer POWER Engineers,

More information

DEVELOP YOUR TAILORED CYBERSECURITY ROADMAP

DEVELOP YOUR TAILORED CYBERSECURITY ROADMAP ARINC cybersecurity solutions DEVELOP YOUR TAILORED CYBERSECURITY ROADMAP Getting started is as simple as assessing your baseline THE RIGHT CYBERSECURITY SOLUTIONS FOR YOUR UNIQUE NEEDS Comprehensive threat

More information

Security Standards for Electric Market Participants

Security Standards for Electric Market Participants Security Standards for Electric Market Participants PURPOSE Wholesale electric grid operations are highly interdependent, and a failure of one part of the generation, transmission or grid management system

More information

BUSINESS CONTINUITY MANAGEMENT PROGRAM OVERVIEW

BUSINESS CONTINUITY MANAGEMENT PROGRAM OVERVIEW BUSINESS CONTINUITY MANAGEMENT PROGRAM OVERVIEW EXECUTIVE SUMMARY CenturyLink is committed to ensuring business resiliency and survivability during an incident or business disruption. Our Corporate Business

More information

NERC Monitoring and Situational Awareness Conference: Loss of Control Center Procedures and Testing Practices

NERC Monitoring and Situational Awareness Conference: Loss of Control Center Procedures and Testing Practices NERC Monitoring and Situational Awareness Conference: Loss of Control Center Procedures and Testing Practices Ed Batalla Director of Technology Florida Power & Light Company September 19, 2013 Florida

More information

Categorizing Cyber Systems

Categorizing Cyber Systems Categorizing Cyber Systems An Approach Based on BES Reliability Functions NERC Cyber Security Standards Drafting Team for Order 706 06/15/2009 Team CATEGORIZING CYBER SYSTEMS: AN APPROACH BASED ON IMPACT

More information

WISP. Western Interconnection Synchrophasor Program. Vickie VanZandt & Dan Brancaccio NASPI Work Group Meeting October 17-18, 2012

WISP. Western Interconnection Synchrophasor Program. Vickie VanZandt & Dan Brancaccio NASPI Work Group Meeting October 17-18, 2012 WISP Western Interconnection Synchrophasor Program Vickie VanZandt & Dan Brancaccio NASPI Work Group Meeting October 17-18, 2012 1 Acknowledgement and Disclaimer Acknowledgment: This material is based

More information

DRAFT. Standard 1300 Cyber Security

DRAFT. Standard 1300 Cyber Security These definitions will be posted and balloted along with the standard, but will not be restated in the standard. Instead, they will be included in a separate glossary of terms relevant to all standards

More information

REAL-TIME MONITORING DATA SPECIFICATION

REAL-TIME MONITORING DATA SPECIFICATION REAL-TIME MONITORING DATA SPECIFICATION Version 1 December 9, 2016 Revision History Version Date Reviewer Revisions 1 11/1/16 Mansion Hudson Initial document 1 Contents 1. DOCUMENT REVIEW... 3 2. DEFINITIONS...

More information

Real-time Power System Operation. Energy Management Systems. Introduction

Real-time Power System Operation. Energy Management Systems. Introduction 1 Real-time Power System Operation Energy Management Systems Introduction The time frame for Power Systems Operation varies from a few seconds to a week. To assist with the operation of the system, modern

More information

Reliability Coordinator Procedure

Reliability Coordinator Procedure No. Table of Contents Purpose... 1 1. Responsibilities... 2 2. Scope/ Applicability... 2 2.1. Background... 2 2.2. Scope... 2 2.3. Applicability... 3 3. Detail... 3 3.1. Format and Security Protocols...

More information

Perry. Lakeshore. Avon. Eastlake

Perry. Lakeshore. Avon. Eastlake Perry Lorain Avon Lakeshore Eastlake Ashtabula Mansfield Sammis Beaver Valley Conesville Tidd Burger & Kammer Muskingum Perry Lorain Avon Lakeshore Eastlake Ashtabula Mansfield Sammis Beaver Valley Conesville

More information

Automation Services and Solutions

Automation Services and Solutions Automation Services and Solutions Automate substation data acquisition and control to improve performance Maintain uninterrupted power services with proactive grid monitoring and controlling features.

More information

CAISO RIG Acceptance Test Procedure

CAISO RIG Acceptance Test Procedure CAISO RIG Acceptance Test Procedure TABLE OF CONTENTS 1.0 PURPOSE... 3 2.0 INTRODUCTION... 3 3.0 TEST PROCEDURE... 8 Market Services/ EDAS CAISO Public Revision History 1.0 PURPOSE The procedure is intended

More information

California Independent System Operator Corporation Fifth Replacement Electronic Tariff

California Independent System Operator Corporation Fifth Replacement Electronic Tariff Table of Contents Appendix M... 2 Dynamic Scheduling Protocol (DSP)... 2 1. DYNAMIC SCHEDULES OF IMPORTS TO THE CAISO BALANCING AUTHORITY AREA... 2 1.2 Contractual Relationships... 2 1.3 Communications,

More information

ERO Enterprise IT Projects Update

ERO Enterprise IT Projects Update ERO Enterprise IT Projects Update Stan Hoptroff, Vice President, Chief Technology Officer and Director of Information Technology Technology and Security Committee Meeting November 6, 2018 Agenda ERO IT

More information

Integrated Resource Planning April 20, 2010

Integrated Resource Planning April 20, 2010 Integrated Resource Planning April 20, 2010 Judy Stokey, Executive Government and External Affairs Jack McGinley, Development Director, Renewables Gary Smith, Project Director-Smart Technologies Presentation

More information

January 22, The Honorable Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, N.E. Washington, D.C.

January 22, The Honorable Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, N.E. Washington, D.C. California Independent System Operator Corporation January 22, 2013 The Honorable Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, N.E. Washington, D.C. 20426 Re: California

More information

locuz.com SOC Services

locuz.com SOC Services locuz.com SOC Services 1 Locuz IT Security Lifecycle services combine people, processes and technologies to provide secure access to business applications, over any network and from any device. Our security

More information

Standards Authorization Request Form

Standards Authorization Request Form Standards Authorization Request Form When completed, email this form to: sarcomm@nerc.com NERC welcomes suggestions to improve the reliability of the bulk power system through improved reliability standards.

More information

Evolution of Control for the Power Grid

Evolution of Control for the Power Grid Evolution of Control for the Power Grid Anjan Bose Washington State University Pullman, WA, USA PaiFest In Honor of Prof. M. A. Pai Urbana-Champaign, IL October 15, 2015 The Past (before 1960s) Hard

More information

RFTS to Reduce OPEX Costs for FTTH Deployments

RFTS to Reduce OPEX Costs for FTTH Deployments RFTS to Reduce OPEX Costs for FTTH Deployments Troy Veitenheimer, General Manager Jorge Cano, President Christopher Dorny, VP of Marketing NTest Inc. sales@ntestinc.com Phone: (952) 252-1221 www.ntestinc.com

More information

Chapter 2 State Estimation and Visualization

Chapter 2 State Estimation and Visualization Chapter 2 State Estimation and Visualization One obvious application of GPS-synchronized measurements is the dynamic monitoring of the operating conditions of the system or the dynamic state estimation

More information

Québec Interconnection Approach to BES

Québec Interconnection Approach to BES Québec Interconnection Approach to BES Placer une photo ici s il y a lieu NPCC Governmental/Regulatory Affairs Advisory Group Sylvain Clermont November 27, 2012 Introduction: HQT Our mission HQT operates

More information

DRAFT Risks and Mitigations for Losing EMS Functions

DRAFT Risks and Mitigations for Losing EMS Functions DRAFT Risks and Mitigations for Losing EMS Functions 1.0 Executive Summary Energy Management System (EMS) is a system of computer-aided tools used by System Operators to monitor, control, and optimize

More information

CIP Cyber Security Recovery Plans for BES Cyber Systems

CIP Cyber Security Recovery Plans for BES Cyber Systems A. Introduction 1. Title: Cyber Security Recovery Plans for BES Cyber Systems 2. Number: CIP-009-6 3. Purpose: To recover reliability functions performed by BES Cyber Systems by specifying recovery plan

More information

CIP-014. JEA Compliance Approach. FRCC Fall Compliance Workshop Presenter Daniel Mishra

CIP-014. JEA Compliance Approach. FRCC Fall Compliance Workshop Presenter Daniel Mishra CIP-014 JEA Compliance Approach FRCC Fall Compliance Workshop Presenter Daniel Mishra Acronyms & Terminologies DHS Department of Homeland Security JEA It s not an acronym JSO Jacksonville Sheriff's Office

More information

CIP Cyber Security Configuration Management and Vulnerability Assessments

CIP Cyber Security Configuration Management and Vulnerability Assessments Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective. Development Steps Completed

More information

Advanced Monitoring Technologies for Grid Reliability, Market Efficiency, and Grid Security

Advanced Monitoring Technologies for Grid Reliability, Market Efficiency, and Grid Security Advanced Monitoring Technologies for Grid Reliability, Market Efficiency, and Grid Security CERTS Briefing for Kevin Kolevar, Director Office of Electricity and Energy Assurance Department of Energy Washington,

More information

Agenda Event Analysis Subcommittee Conference Call

Agenda Event Analysis Subcommittee Conference Call Agenda Event Analysis Subcommittee Conference Call August 14, 2013 11:00 a.m. 1:00 p.m. Eastern Ready Talk Conference Call and Web Meeting Information: Dial-In: 1-866-740-1260 Access Code: 6517175 Security

More information

This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective.

This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective. Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective. Development Steps Completed

More information

Intro to the NERC/NIPC Indications, Analysis & Warnings Program

Intro to the NERC/NIPC Indications, Analysis & Warnings Program Intro to the NERC/NIPC Indications, Analysis & Warnings Program (IAW Program - Electric Power Sector) Before Seeing this Presentation, Make Sure Everyone Has a Copy of Each of the Following: Job Aid (NIPC

More information

Practical Uses of PI AF

Practical Uses of PI AF Practical Uses of PI AF Matt Rivett Sr. OSI PI Developer PJM Interconnection Date Forum Name Agenda About PJM PI AF Infrastructure AF Databases Generator AGC Synchrophasor Thunder Storm Alert Server Monitoring

More information

PG&E Transmission Interconnection Handbook

PG&E Transmission Interconnection Handbook Table of Contents TABLE OF CONTENTS... 1 UPDATE HISTORY... UP-1 INTRODUCTION... IN-1 I-1. PURPOSE... IN-1 I-2. INTRODUCTORY DEFINITIONS... IN-1 I-3. HANDBOOK APPLICABILITY... IN-2 I-3.1. New Load, New

More information

Cyber Security Update. Bennett L. Gaines Senior Vice President, Corporate Services, CIO, FirstEnergy 2012 Summer Seminar August 5-7, 2012

Cyber Security Update. Bennett L. Gaines Senior Vice President, Corporate Services, CIO, FirstEnergy 2012 Summer Seminar August 5-7, 2012 Cyber Security Update Bennett L. Gaines Senior Vice President, Corporate Services, CIO, FirstEnergy 2012 Summer Seminar August 5-7, 2012 Agenda Timeline Regulatory / Compliance Environment Smart Grid Threats

More information

Standard Authorization Request Form

Standard Authorization Request Form Title of Proposed Standard Cyber Security Request Date May 2, 2003 SAR Requestor Information Name Charles Noble (on behalf of CIPAG) Company Telephone SAR Type (Check box for one of these selections.)

More information

Title. Critical Infrastructure Protection Getting Low with a Touch of Medium. CanWEA Operations and Maintenance Summit 2018.

Title. Critical Infrastructure Protection Getting Low with a Touch of Medium. CanWEA Operations and Maintenance Summit 2018. Critical Infrastructure Protection Getting Low with a Touch of Medium Title CanWEA Operations and Maintenance Summit 2018 January 30, 2018 George E. Brown Compliance Manager Acciona Wind Energy Canada

More information

Proposed Convention for Numbering of NERC Reliability Standards Draft September 9, 2004

Proposed Convention for Numbering of NERC Reliability Standards Draft September 9, 2004 Proposed Convention for ing of NERC Reliability s Draft September 9, 2004 Introduction The Version 0 Drafting Team proposes to initiate a new convention for numbering NERC reliability standards concurrent

More information

SDG&E s Accomplishments and Future Plans

SDG&E s Accomplishments and Future Plans SDG&E s Accomplishments and Future Plans Tariq Raman and Subbu Sankaran San Diego Gas & Electric Work Group Meeting October 23-24, 2018 San Diego Gas & Electric San Francisco SDG&E Los Angeles San Diego

More information

A Hybrid Communications Network Approach for Advanced Applications on the Modern Grid

A Hybrid Communications Network Approach for Advanced Applications on the Modern Grid A Hybrid Communications Network Approach for Advanced Applications on the Modern Grid Mark A. Carella, PE Manager Distribution Control and Integration nationalgrid Private Telecom Network Key Stats Private

More information

CIP Cyber Security Personnel & Training

CIP Cyber Security Personnel & Training A. Introduction 1. Title: Cyber Security Personnel & Training 2. Number: CIP-004-5.1 3. Purpose: To minimize the risk against compromise that could lead to misoperation or instability in the BES from individuals

More information

NERC and Regional Coordination Update. Operating Committee Preston Walker January 9, 2018

NERC and Regional Coordination Update. Operating Committee Preston Walker January 9, 2018 NERC and Regional Coordination Update Operating Committee Preston Walker January 9, 2018 Standards Project Action End Date Project 2017-07 Standards Alignment with Registration NERC Standards Under Development

More information

WISP. Western Interconnection Synchrophasor Program. Vickie VanZandt & Dan Brancaccio NASPI Work Group Meeting October 22-24, 2013

WISP. Western Interconnection Synchrophasor Program. Vickie VanZandt & Dan Brancaccio NASPI Work Group Meeting October 22-24, 2013 WISP Western Interconnection Synchrophasor Program Vickie VanZandt & Dan Brancaccio NASPI Work Group Meeting October 22-24, 2013 1 Acknowledgement and Disclaimer Acknowledgment: This material is based

More information

Reliability Standard Audit Worksheet 1

Reliability Standard Audit Worksheet 1 Reliability Standard Audit Worksheet 1 CIP-002-5.1 Cyber Security BES Cyber System Categorization This section to be completed by the Compliance Enforcement Authority. Audit ID: Registered Entity: NCR

More information

THE TRIPWIRE NERC SOLUTION SUITE

THE TRIPWIRE NERC SOLUTION SUITE CONFIDENCE: SECURED BUSINESS INTELLIGENCE SOLUTION BRIEF THE TRIPWIRE NERC SOLUTION SUITE A TAILORED SUITE OF PRODUCTS AND SERVICES TO AUTOMATE NERC CIP COMPLIANCE u u We ve been able to stay focused on

More information

Network Performance, Security and Reliability Assessment

Network Performance, Security and Reliability Assessment Network Performance, Security and Reliability Assessment Presented to: CLIENT NAME OMITTED Drafted by: Verteks Consulting, Inc. 2102 SW 20 th Place, Suite 602 Ocala, Fl 34474 352-401-0909 ASSESSMENT SCORECARD

More information

ENGINEERING AND SERVICES FIRM THAT SPECIALIZES IN HYDROELECTRIC POWER AND CONTROL SYSTEM DESIGN, OUR TEAM OF PROFESSIONALS HAVE WORKED TOGETHER

ENGINEERING AND SERVICES FIRM THAT SPECIALIZES IN HYDROELECTRIC POWER AND CONTROL SYSTEM DESIGN, OUR TEAM OF PROFESSIONALS HAVE WORKED TOGETHER smallhydro PRIME ENGINEERING LIMITED IS AN ELECTRICAL ENGINEERING AND SERVICES FIRM THAT SPECIALIZES IN HYDROELECTRIC POWER AND CONTROL SYSTEM DESIGN, IMPLEMENTATION AND MAINTENANCE. OUR TEAM OF PROFESSIONALS

More information

TransWest Express Transmission Project Interregional Transmission Project Submittal

TransWest Express Transmission Project Interregional Transmission Project Submittal TransWest Express Transmission Project 2016 2017 Interregional Transmission Project Submittal Submittals to California Independent System Operator, WestConnect and Northern Tier Transmission Group March

More information

Securing the Grid and Your Critical Utility Functions. April 24, 2017

Securing the Grid and Your Critical Utility Functions. April 24, 2017 Securing the Grid and Your Critical Utility Functions April 24, 2017 1 Securing the Grid Effectively and Efficiently Recent threats to the Electric Grid and the importance of security Standards and Requirements

More information

Southwest Power Pool Independent Coordinator of Transmission RELIABILITY PLAN for Entergy in the Southeastern Electric Reliability Council September

Southwest Power Pool Independent Coordinator of Transmission RELIABILITY PLAN for Entergy in the Southeastern Electric Reliability Council September Southwest Power Pool Independent Coordinator of Transmission RELIABILITY PLAN for Entergy in the Southeastern Electric Reliability Council September 23, 2009 TABLE OF CONTENTS INTRODUCTION A. RESPONSIBILITIES

More information

ENERGY MANAGEMENT SYSTEM. ABB Ability Network Manager EMS Operational confidence.

ENERGY MANAGEMENT SYSTEM. ABB Ability Network Manager EMS Operational confidence. ENERGY MANAGEMENT SYSTEM ABB Ability Network Manager EMS Operational confidence. 2 ABB ABILITY NETWORK MANAGER EMS ABB Ability Network Manager Energy Management System The ever-increasing demand for power

More information

DRAFT. Cyber Security Communications between Control Centers. March May Technical Rationale and Justification for Reliability Standard CIP-012-1

DRAFT. Cyber Security Communications between Control Centers. March May Technical Rationale and Justification for Reliability Standard CIP-012-1 DRAFT Cyber Security Communications between Control Centers Technical Rationale and Justification for Reliability Standard CIP-012-1 March May 2018 NERC Report Title Report Date I Table of Contents Preface...

More information

Peak Reliability Coordination Services in the West March 30, 2018

Peak Reliability Coordination Services in the West March 30, 2018 Peak Reliability Coordination Services in the West March 30, 2018 Peak Reliability, 2018. 1 Peak Reliability Coordination Services in the West Peak s fundamental mission is to enhance and promote the reliability

More information

UCLA AUDIT & ADVISORY SERVICES

UCLA AUDIT & ADVISORY SERVICES UCLA AUDIT & ADVISORY SERVICES Edwin D. Pierce, CPA, CFE Director September 4, 2015 10920 Wilshire Boulevard, Suite 700 Los Angeles, California 90024-1366 310 794-6110 Fax: 310 794-8536 SENIOR VICE PRESIDENT/CHIEF

More information

Distributor Thoughts on Smart Grid

Distributor Thoughts on Smart Grid Distributor Thoughts on Smart Grid Sylvia Smith Budget & Rates Manager Tony Richman Meter Services Manager-Smart Grid 1 Agenda Introduction Smart Grid Program Strategy & Technical Aspects Financial Considerations

More information

Future Grid Initiative

Future Grid Initiative Future Grid Initiative Enabling renewable energy resources Vijay Vittal Director, Power Systems Engineering Research Center Professor, Arizona State University Workshop objectives PSERC has embarked on

More information

Cyber Threats? How to Stop?

Cyber Threats? How to Stop? Cyber Threats? How to Stop? North American Grid Security Standards Jessica Bian, Director of Performance Analysis North American Electric Reliability Corporation AORC CIGRE Technical Meeting, September

More information

ASSURING BUSINESS CONTINUITY THROUGH CONTROLLED DATA CENTER

ASSURING BUSINESS CONTINUITY THROUGH CONTROLLED DATA CENTER ASSURING BUSINESS CONTINUITY THROUGH CONTROLLED DATA CENTER IT Audit, Information Security & Risk Insight Africa 2014 Johnson Falana CISA,MIT,CEH,Cobit5 proverb814@yahoo.com Overview Information technology

More information

CIP Cyber Security Systems Security Management

CIP Cyber Security Systems Security Management A. Introduction 1. Title: Cyber Security System Security Management 2. Number: CIP-007-5 3. Purpose: To manage system security by specifying select technical, operational, and procedural requirements in

More information

Agenda Event Analysis Subcommittee Conference Call

Agenda Event Analysis Subcommittee Conference Call Agenda Event Analysis Subcommittee Conference Call October 23, 2013 11:00 a.m. 1:00 p.m. Eastern Ready Talk Conference Call and Web Meeting Information: Dial-In: 1-866-740-1260 Access Code: 6517175 Security

More information

Standard CIP Cyber Security Critical Cyber Asset Identification

Standard CIP Cyber Security Critical Cyber Asset Identification Standard CIP 002 1 Cyber Security Critical Cyber Asset Identification Standard Development Roadmap This section is maintained by the drafting team during the development of the standard and will be removed

More information

Dude Solutions Business Continuity Overview

Dude Solutions Business Continuity Overview Dude Solutions Business Continuity Overview Table of Contents Overview.... 2 Primary and Disaster Recovery Data Centers.... 2 Network Infrastructure.... 3 Emergency Processes.... 3 Power and Cooling Systems....

More information

INCIDENTRESPONSE.COM. Automate Response. Did you know? Your playbook overview - Elevation of Privilege

INCIDENTRESPONSE.COM. Automate Response. Did you know? Your playbook overview - Elevation of Privilege Automate Response Congratulations on selecting IncidentResponse.com to retrieve your custom incident response playbook guide. This guide has been created especially for you for use in within your security

More information

2011 North American SCADA & Process Control Summit March 1, 2011 Orlando, Fl

2011 North American SCADA & Process Control Summit March 1, 2011 Orlando, Fl Beyond Compliance Greg Goodrich Supervisor, Enterprise Security New York Independent System Operator 2011 North American SCADA & Process Control Summit March 1, 2011 Orlando, Fl Roles of the NYISO Reliable

More information

CIP Cyber Security Security Management Controls. Standard Development Timeline

CIP Cyber Security Security Management Controls. Standard Development Timeline Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective. Development Steps Completed

More information

Glencoe Light and Power

Glencoe Light and Power Glencoe Light and Power REQUIREMENTS FOR GENERATION, TRANSMISSION, AND END-USER FACILITY INTERCONNECTIONS 1 Table of Contents Page I. INTRODUCTION...5 A. Authority... 5 B. Objectives...5 C. Interconnection

More information

Standard CIP Cyber Security Critical Cyber Asset Identification

Standard CIP Cyber Security Critical Cyber Asset Identification Standard CIP 002 1 Cyber Security Critical Cyber Asset Identification Standard Development Roadmap This section is maintained by the drafting team during the development of the standard and will be removed

More information

Business Continuity Management Program Overview

Business Continuity Management Program Overview Business Continuity Management Program Overview Improving the lives of our customers by connecting them to the power of the digital world CenturyLink Key Objective CenturyLink may modify or terminate this

More information

Standard INT Dynamic Transfers

Standard INT Dynamic Transfers A. Introduction 1. Title: Dynamic Transfers 2. Number: INT-004-3 3. Purpose: To ensure Dynamic Schedules and Pseudo-Ties are communicated and accounted for appropriately in congestion management procedures.

More information

CIP Cyber Security Recovery Plans for BES Cyber Systems

CIP Cyber Security Recovery Plans for BES Cyber Systems Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective. Development Steps Completed

More information

Welcome! EH2741 Communications & Control in Power Systems. Lars Nordström

Welcome! EH2741 Communications & Control in Power Systems. Lars Nordström 1 Welcome! EH2741 Communications & Control in Power Systems Lars Nordström larsno@kth.se 2 Outline Administration Few words about the department Walk through of course syllabus Demonstration of KTH-social

More information

Small Generator Interconnection System Impact Study Report. Completed For Q0047

Small Generator Interconnection System Impact Study Report. Completed For Q0047 Small Generator Interconnection Completed For Q0047 Proposed Interconnection PacifiCorp s Existing Goshen Rigby 69 kv Line March 7, 2005 1.0 Description of the Generation Facility Q0047 ( Interconnection

More information

NERC CIP Information Protection

NERC CIP Information Protection NERC CIP Information Protection Eric Ruskamp Manager, Regulatory Compliance September 13, 2017 1 Agenda NERC History NERC Compliance Overview of Reliability Standards Compliance with Reliability Standards

More information

Regulatory Impacts on Research Topics. Jennifer T. Sterling Director, Exelon NERC Compliance Program

Regulatory Impacts on Research Topics. Jennifer T. Sterling Director, Exelon NERC Compliance Program Regulatory Impacts on Research Topics Jennifer T. Sterling Director, Exelon NERC Compliance Program The 2003 Blackout On August 14, 2003, an electric power blackout affected large portions of the Northeast

More information

Infrastructure Security Overview

Infrastructure Security Overview White Paper Infrastructure Security Overview Cisco IronPort Cloud Email Security combines best-of-breed technologies to provide the most scalable and sophisticated email protection available today. Based

More information

Generation Interconnection Feasibility Study Report

Generation Interconnection Feasibility Study Report Project #169 Generation Interconnection Feasibility Study Report 7/2/2014 Regional Electric Transmission Planning TABLE OF CONTENTS Executive Summary... 3 Generator and Interconnection Data... 5 Study

More information

CIP Cyber Security Personnel & Training

CIP Cyber Security Personnel & Training A. Introduction 1. Title: Cyber Security Personnel & Training 2. Number: CIP-004-6 3. Purpose: To minimize the risk against compromise that could lead to misoperation or instability in the Bulk Electric

More information

primary Control Center, for the exchange of Real-time data with its Balancing

primary Control Center, for the exchange of Real-time data with its Balancing A. Introduction 1. Title: Reliability Coordination Monitoring and Analysis 2. Number: IRO-002-5 3. Purpose: To provide System Operators with the capabilities necessary to monitor and analyze data needed

More information

Intelligent Grid and Lessons Learned. April 26, 2011 SWEDE Conference

Intelligent Grid and Lessons Learned. April 26, 2011 SWEDE Conference Intelligent Grid and Lessons Learned April 26, 2011 SWEDE Conference Outline 1. Background of the CNP Vision for Intelligent Grid 2. Implementation of the CNP Intelligent Grid 3. Lessons Learned from the

More information

CIP Cyber Security Recovery Plans for BES Cyber Systems

CIP Cyber Security Recovery Plans for BES Cyber Systems A. Introduction 1. Title: Cyber Security Recovery Plans for BES Cyber Systems 2. Number: CIP-009-5 3. Purpose: To recover reliability functions performed by BES Cyber Systems by specifying recovery plan

More information

INTERCONNECTION FACILITIES STUDY REPORT

INTERCONNECTION FACILITIES STUDY REPORT Interconnection Request No. TI-08-0312 INTERCONNECTION FACILITIES STUDY REPORT Prepared by Tri-State Generation and Transmission Association, Inc. 1 of 7 DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES

More information

Substation. Communications. Power Utilities. Application Brochure. Typical users: Transmission & distribution power utilities

Substation. Communications. Power Utilities. Application Brochure. Typical users: Transmission & distribution power utilities Power Utilities Application Brochure Communications Typical users: Transmission & distribution power utilities For more than 30 years, RAD has worked closely with its worldwide energy utility customers

More information

New Brunswick 2018 Annual Implementation Plan Version 1

New Brunswick 2018 Annual Implementation Plan Version 1 New Brunswick Energy and Utilities Board Reliability Standards, Compliance and Enforcement Program New Brunswick 2018 Annual Implementation Plan Version 1 December 28, 2017 Table of Contents Version History...

More information

CIP Cyber Security Configuration Change Management and Vulnerability Assessments

CIP Cyber Security Configuration Change Management and Vulnerability Assessments CIP 010 1 Cyber Security Configuration Change Management and Vulnerability Assessments A. Introduction 1. Title: Cyber Security Configuration Change Management and Vulnerability Assessments 2. Number:

More information

Cybersecurity for the Electric Grid

Cybersecurity for the Electric Grid Cybersecurity for the Electric Grid Electric System Regulation, CIP and the Evolution of Transition to a Secure State A presentation for the National Association of Regulatory Utility Commissioners March

More information

SECURING THE SUPPLY CHAIN

SECURING THE SUPPLY CHAIN SECURING THE SUPPLY CHAIN BY Jerome Farquharson, CISSP, Donald Dustin Williams, PE, AND Courtney Buser The advance of smart grids, smart devices and increasingly interconnected systems provides exceptional

More information

Standard CIP Cyber Security Critical Cyber As s et Identification

Standard CIP Cyber Security Critical Cyber As s et Identification A. Introduction 1. Title: Cyber Security Critical Cyber Asset Identification 2. Number: CIP-002-4 3. Purpose: NERC Standards CIP-002-4 through CIP-009-4 provide a cyber security framework for the identification

More information