0.1. [0x8A] Read Configuration
|
|
- Lillian Chase
- 5 years ago
- Views:
Transcription
1 0.1. [0x8A] Read Configuration The Read Configuration Protocol is defined to query the complete or parts of reader configuration. This protocol is an extension of [0x80] Read Configuration and realizes many improvements: 1. several destinations are addressable 2. one, multiple or all configuration blocks can be read 3. the address range is up to configuration blocks for each destination 4. different configuration locations for each destination are addressable 5. several block sizes are supported 6. protocol ignores read protected configuration blocks and returns only readable configuration blocks Reader: x02 LENGTH COM-ADR [0x8A] DEVICE BANK MODE CFG-ADR CFG-N CRC16 Reader x02 LENGTH COM-ADR [0x8A] STATUS 7 8 9, byte CFG-N BLOCK- SIZE CFG-ADR CFG-DATA CRC16 Repeated CFG-N times FEIG ELECTRONIC GmbH Seite 1 von 9
2 DEVICE: The DEVICE identifies the target controller inside the reader. The following devices are acceptable: DEVICE AC-Controller Value BANK: The BANK addresses a specified memory bank of the target device. The following banks are acceptable: BANK Value Note Main 0x01 For RF-independent settings MODE: The MODE controls the command. The following flags are defined: ALL LOC LOC: ALL: specifies the location of the configuration block b000 RAM b001 EEPROM specifies to read the complete configuration from RAM or EEPROM b0 configuration to be read specified by CFG-ADR and CFG-N b1 read complete configuration. CFG-ADR and CFG-N ignored FEIG ELECTRONIC GmbH Seite 2 von 9
3 CFG-ADR: In Request protocol: First block address of the required configuration blocks. In Response protocol: block address of the following configuration data which builds together a dataset, repeated CFG-N times. CFG-N: In Request protocol: Number of configuration blocks to be read. In Response protocol: Number of returned datasets which consists of a block address and related configuration data. BLOCKSIZE: Number of bytes in each configuration block. CFG-DATA: Returned configuration data. STATUS: Hex-value General 0x00 OK: Data / parameters have been read or stored without error Control command has been executed 0x02 Read Error Read of configuration block failed internally 0x11 Parameter-Range-Error The range of values for one or more parameters were exceeded 0x15 Read Protect This status is returned only if one configuration block (CFG-N = 1) is to be read and the configuration block at this block address is reserved for future use FEIG ELECTRONIC GmbH Seite 3 von 9
4 0.2. [0x8B] Write Configuration The Write Configuration Protocol is defined to change the complete or parts of reader configuration. This protocol is an extension of [0x81] Write Configuration and realizes four improvements: 1. several destinations are addressable 2. one, multiple or all configuration blocks can be written 3. the address range is up to configuration blocks for each destination 4. different configuration locations for each destination are addressable 5. several block sizes are supported 6. protocol ignores write protected configuration blocks and writes only writable configuration blocks Reader: x02 LENGTH COM-ADR [0x8B] DEVICE BANK , byte MODE CFG-N BLOCK- SIZE CFG-ADR CFG-DATA CRC16 Repeated CFG-N times Reader (STATUS = 0x00) x02 LENGTH COM-ADR [0x8B] 0x00 CRC16 FEIG ELECTRONIC GmbH Seite 4 von 9
5 DEVICE: The DEVICE identifies the target controller inside the reader. The following devices are acceptable: DEVICE AC-Controller Value BANK: The BANK addresses a specified memory bank of the target device. The following banks are acceptable: BANK Value Note Main 0x01 For RF-independent settings MODE: The MODE controls the command. The following flags are defined: LOC LOC: specifies the location of the configuration block b000 RAM b001 RAM and EEPROM CFG-N: Number of configuration blocks. BLOCKSIZE: Number of bytes in each configuration block. CFG-ADR: Block address of the related configuration block. CFG-DATA: Configuration block with each BLOCKSIZE bytes related to CFG-ADR. FEIG ELECTRONIC GmbH Seite 5 von 9
6 STATUS: Hex-value General 0x00 OK: Data / parameters have been read or stored without error Control command has been executed Write Error Write of configuration block failed internally 0x11 Parameter-Range-Error: The range of values for one or more parameters were exceeded 0x16 Write Protect This status is returned only if one configuration block (CFG-N = 1) is to be written and the configuration block at this block address is reserved for future use FEIG ELECTRONIC GmbH Seite 6 von 9
7 0.3. [0x8C] Reset Configuration The Reset Configuration Protocol is defined to set the complete or parts of reader configuration to factory default values. This protocol is an extension of [0x84] Reset Configuration and realizes three improvements: 1. several destinations are addressable 2. one, multiple or all configuration blocks can be reset 3. the address range is up to configuration blocks for each destination 4. different configuration locations for each destination are addressable 5. protocol ignores write protected configuration blocks and resets only writable configuration blocks Reader: x02 LENGTH COM-ADR [0x8C] DEVICE BANK MODE CFG-ADR CFG-N CRC16 Reader x02 LENGTH COM-ADR [0x8C] STATUS CRC16 DEVICE: The DEVICE identifies the target controller inside the reader. The following devices are acceptable: DEVICE AC-Controller Value FEIG ELECTRONIC GmbH Seite 7 von 9
8 BANK: The BANK addresses a specified memory bank of the target device. The following banks are acceptable: BANK Value Note Main 0x01 For RF-independent settings MODE: The MODE controles the command. The following flags are defined: LOC LOC: specifies the location of the configuration block b000 RAM b001 RAM and EEPROM ALL: specifies to reset the complete configuration from RAM or EEPROM b0 configuration to be reset specified by CFG-ADR and CFG-N b1 reset complete configuration. CFG-ADR and CFG-N ignored CFG-ADR: First block address of the required configuration blocks. CFG-N: Number of configuration blocks to be reset. FEIG ELECTRONIC GmbH Seite 8 von 9
9 STATUS: Hex-value General 0x00 OK: Data / parameters have been read or stored without error Control command has been executed Write Error Write of configuration block failed internally 0x11 Parameter-Range-Error: The range of values for one or more parameters were exceeded 0x16 Write Protect This status is returned only if one configuration block (CFG-N = 1) is to be reset and the configuration block at this block address is reserved for future use FEIG ELECTRONIC GmbH Seite 9 von 9
History of Firmware Revisions. i-scan. Standard-Reader ID ISCLR200. SWRN ISCLR200 V5.04.doc
History of Firmware Revisions i-scan Standard-Reader ID ISCLR200 SWRN ISCLR200 V5.04.doc NOTE Copyright 2000-2006 by FEIG ELECTRONIC GmbH Lange Strasse 4 35781 Weilburg-Waldhausen http://www.feig.de Edition:
More informationMANUAL ID ISC.MR102. Standard-Reader. from Firmware-Version 0.4 or higher. Preliminary public (B) H e-ID-B.doc
MANUAL ID ISC.MR102 Standard-Reader from Firmware-Version 0.4 or higher Preliminary public (B) 2011-04-12 H01113-0e-ID-B.doc Copyright 2011 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen
More informationMANUAL. OBID i-scan ID ISC.MR200. Standard-Reader. from Firmware-Version final public (B) H e-ID-B.doc
OBID i-scan MANUAL ID ISC.MR200 Standard-Reader from Firmware-Version 1.12 final public (B) 2008-05-26 H40801-5e-ID-B.doc Copyright 2004-2008 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen
More informationCommunication FU UHF
OBID i-scan MANUAL Communication FU UHF Communication Function Unit UHF Function Unit Commands Reader FU (Function Unit) final public (B) 2008-05-30 H80302-0e-ID-B.doc Copyright 2008 by FEIG ELECTRONIC
More informationTSB Software Reference Manual
TSB Software Reference Manual Temperature Sensors Board Commands Description L. Castellani I.N.F.N. sez. PADOVA 10 December 2009 Document Version 1.4 Firmware Version 2.5 Introduction The TSB emulate the
More informationApplication Note. MLX90129 Sensor Tag Applications. Scope. Applications. Related Melexis Products. Introduction
Scope This application note gives some guidelines to detail the use of the MLX90129 for RFID sensor tag applications. The different command sequences to read a sensor and the power check system are described.
More informationambient XC RS232 Control Command Specification
ambient XC RS232 Control Command Specification Table of Contents ambient XC RS232 Control Command Specification...1 Goal...2 COM port properties...2 Initialisation of RS232 communication...2 Determine
More informationJUMO ctron 04/08/16. Compact controller with timer and ramp function. B Interface Description Modbus /
JUMO ctron 04/08/16 Compact controller with timer and ramp function 702071 702072 702074 B 70.2070.2.0 Interface Description Modbus 2008-08-11/00492538 Contents 1 Introduction 5 1.1 Preface... 5 1.2 Typographical
More informationGetting Started with ID ISC.LR(M)U1000/2000 UHF-Reader
Getting Started with ID ISC.LR(M)U1000/2000 UHF-Reader FEIG ELECTRONIC GmbH, Lange Strasse 4, D-35781 Weilburg (tel) +49 (0) 6471 3109 0, (fax) +49 (0) 6471 3109 99 (web) http://www.feig.de (email) OBID@feig.de
More informationID ISC.LRU1000 MANUAL. OBID i-scan. Standard-Reader. Firmware-Version 1.09 RF Controller. and 1.04 ACC. and higher
OBID i-scan MANUAL ID ISC.LRU1000 Standard-Reader Firmware-Version 1.09 RF Controller and 1.04 ACC and higher final public (B) 2006-05-31 H40802-3e-ID-B.doc Copyright 2004-2006 by FEIG ELECTRONIC GmbH
More informationInstruction manual EFR4000IP
ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße 13, D 74523 Schwäbisch Hall + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panelmeters MINIPAN
More informationFPGA ACC
MANUAL ID ISC.LR2000 Standard-Reader from Firmware-Version RFC 1.17.00 FPGA 2.00.04 ACC 2.02.00 final public (B) 2011-04-21 H60700-3e-ID-B.doc Copyright 2006-2011 by FEIG ELECTRONIC GmbH Lange Strasse
More informationID CPR40.xx-Family. Desktop Reader: ID CPR40.30-USB ID CPR40.30-SUSB ID CPR40.30-A. Reader Module:
MANUAL ID CPR40.xx-Family Desktop Reader: ID CPR40.30-USB ID CPR40.30-SUSB ID CPR40.30-A Reader Module: ID CPR40.00-CD 3.3 ID CPR40.01-CD 3.3 ID CPR40.00-A ID CPR40.01-A ID CPR40.00-CDUSB ID CPR40.01-CDUSB
More informationCommunication Protocol WH4013
Jun 14 Communication Protocol WH4013 Static Electricity Meter WH4013 Electronic Electricity Meter for DIN Rail-Assembling Date 11.06.2014 Last changes 02.07.2014 DZG Metering GmbH, Heidelberger Str. 32,
More informationModbus Communication Protocol
July 14 Modbus Communication Protocol Static Electricity Meter WH4013 Date 11.06.2014 Last changes 03.07.2014 DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg The contents of this user manual
More informationMOBY D C/C++ MDWAPI. Programming instructions. General information Table of Contents SLG D10. Overview 1. Configuration parameters 2
General information Table of Contents MOBY D Programming instructions SLG D10 Overview 1 Configuration parameters 2 Description of protocols 3 SLG D11/D12 Overview 4 Configuration parameters 5 Description
More informationID ISC.LR200-A/B First Steps to get the Serial Number from a Transponder
1 Preparation ID ISC.LR200-A/B First Steps to get the Serial Number from a Transponder (Using ISOStart Version 6.0 or higher) 1 Connect the ID ISC.LR200 via RS232 or RS485 to the PC 2 Install the Demo
More informationM-BUS Standard acc. EN AE.05:04.01: Protocol Specification
M-BUS Standard acc. EN 13757 AE.05:04.01:01.01 Protocol Specification Manufacturer: Elster GmbH Strotheweg 1 49504 Lotte Germany Änd.Nr.: 510400 1000470754 000 00 ZSD A Seite 1 von 17 Contents 1. Introduction...
More informationJUMO Quantrol LC100/LC200/LC300
JUMO Quantrol LC100/LC200/LC300 Universal PID Controller Series B 702030.2.0 Interface Description Modbus 2013-05-27/00600589 Content 1 Introduction................................................ 5 1.1
More informationJUMO di 308. Digital Indicator. B Interface Description Modbus 12.07/
JUMO di 308 Digital Indicator B 70.1550.2.0 Interface Description Modbus 12.07/00485372 Contents 1 Introduction 5 1.1 Preface... 5 1.2 Typographical conventions... 6 1.2.1 Warning signs... 6 1.2.2 Note
More informationConto D2 COMMUNICATION PROTOCOL CONTENTS 1.0 INTRODUCTION
PR 121 rev. 0 11/11/2011 Pagina 1 di 9 ELECTRICITY ENERGY METER FIRMWARE 1.6 Conto D2 COMMUNICATION PROTOCOL CONTENTS 1.0 INTRODUCTION 2.0 DATA MESSAGE DESCRIPTION 2.1 Data field description 2.2 Data format
More informationInstruction Manual Modbus Converter Unigate-CL-RS
BA_MODBUS-Gateway_e_2011-12-16.doc, Stand: 16.12.2011 (Subject to technical changes) 1 Introduction The Unigate-CL-RS Module serves as gateway between the ExTox RS232 Interface and the bus system of the
More informationVenstar Thermostat Adapter
Developer Venstar Thermostat Adapter v001 Developer Venstar Thermostat Adapter Version 001 May 23, 2013 Revision History Rev Date Comments 001 05/23/13 Initial Release Page 1 of 13 Table of Contents 1
More informationME 475 Lab2 Introduction of PIC and Programming. Instructor: Zhen Wang
ME 475 Lab2 Introduction of PIC and Programming Instructor: Zhen Wang 2013.1.25 Outline Lecture Introduction of PIC microcontroller Programming cycle Read CH5 Programming guidelines Read CH6 Sample program
More informationProtocol of SOJI Fuel level sensor FJ-RS232/FJ-RS485 Version 1.0.2
Protocol of SOJI Fuel level sensor FJRS232/FJRS485 Version 1.0.2 Document preparion Full Name Title Prepared by Nguyen Duy Tan Engineer Approved by Quang Nguyen Project manager Date 1 October 2016 1 October
More informationSC2004MBS 20x4 Characters MODBUS RTU Slave LCD
SC004MBS 0x4 Characters MODBUS RTU Slave SC004MBS is a MODBUS slave device that receives data from a Master MODBUS device and display them on the panel. The is 0 x 4 characters in size and each character
More informationModBus Communication protocol. The ModBus protocol is an industrial communications and distributed control system
ModBus Communication protocol ModBus Communication Standards The ModBus protocol is an industrial communications and distributed control system to integrate PLCs, computers, terminals, and other monitoring,
More information4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM102(1739) For 4511 devices from ser. no:
4511 MODBUS RTU Configuration Manual HART transparent driver No. 9107MCM102(1739) For 4511 devices from ser. no: 141590001 9107 CONTENTS Introduction... 3 Modbus basics... 3 Modbus RTU... 3 4511 Supported
More informationTPMC815 ARCNET PMC. User Manual. The Embedded I/O Company. Version 2.0. Issue 1.2 November 2002 D
The Embedded I/O Company TPMC815 ARCNET PMC Version 2.0 User Manual Issue 1.2 November 2002 D76815804 TEWS TECHNOLOGIES GmbH Am Bahnhof 7 25469 Halstenbek / Germany Phone: +49-(0)4101-4058-0 Fax: +49-(0)4101-4058-19
More informationVersion Action Author Date
Version Action Author Date 1.0 Initial document KP 25.08.2013 1.1 Document review, description and register update GP 26.08.2013 1.2 Status bits, current noise floor GP 29.08.2013 1.3 Using EG100 as a
More informationRevision 1.2. July 24, COM Protocol Manual. for MDC and ADC N 11th St - San Jose CA
Revision 1.2 July 24, 2017 COM Protocol Manual for MDC and ADC www.mountztorque.com - 1080 N 11th St - San Jose CA 95112-408.292.2214 1 1 Overview and Communication Specifications 1.1 Overview If the PC
More informationID CPR40.xx-xx. History of Firmware Revisions. Desktop Reader: ID CPR40.30-USB ID CPR40.30-SUSB ID CPR40.30-A. Reader Module:
RELEASE-NOTE ID CPR40.xx-xx History of Firmware Revisions Desktop Reader: Reader Module: final public 2012-03-06 SWRN CPR40xx.doc Copyright 2012 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen
More informationRotel RS232 Serial Bus Communication
Rotel RS232 Serial Bus Communication 1. 1 Byte Waveform format 5V STOP START 0V LSB:Bit0 MSB:Bit7 2. Bus Status Test 2~10ms Message Message A. Test starts to see if line is empty for 2~10msec before transmitting
More informationU9809 UHF RFID Reader User's Manual V1.2
U9809 UHF RFID Reader User's Manual V1.2 Content 1 COMMUNICATION INTERFACE SPECIFICATION... 4 2 PROTOCOL DESCRIPTION... 4 3 DATA BLOCK FORMAT... 5 3.1 COMMAND DATA BLOCK... 5 3.2 RESPONSE DATA BLOCK...
More informationDeveloper Notes INSTEON Thermostat v012. Developer Notes. INSTEON Thermostat. Revision History
Developer INSTEON Thermostat v012 Developer INSTEON Thermostat Version 012 June 19, 2012 Revision History Rev Date Comments 001 10/28/11 Initial Release 002 11/4/11 Updated formatting in some sections
More informationOPTIGRID MOTORIZATION USB HID CLASS INTERFACE INSTRUCTION. Approved by:... Steve Mounnarat, Director of Engineering
OPTIGRID MOTORIZATION USB HID CLASS INTERFACE INSTRUCTION Prepared by:... Mark Knudson, Software Engineer 20 APRIL 2007 Approved by:... Steve Mounnarat, Director of Engineering Version Authorized Date
More informationID ISOStart HANDBUCH V7.02. Demo Program for OBID i-scan and OBID classic-pro Reader. (Windows 98/NT/2000/XP)
OBID HANDBUCH ID ISOStart V7.02 Demo Program for OBID i-scan and OBID classic-pro Reader (Windows 98/NT/2000/XP) final public (B) 2006-10-09 H81291-8e-ID.doc Copyright 2002-2006 by FEIG ELECTRONIC GmbH
More informationB Interface description 12.01/
B 95.3530.2 Interface description 12.01/00340396 Contents 1 Introduction 1.1 Preface... 3 1.2 Typographical conventions... 4 1.2.1 Warning signs... 4 1.2.2 Note signs... 4 1.2.3 Presentation... 4 2 Protocol
More informationIO-Link parameter description
Application Note IO-Link parameter description A brief explanation of the contents - identification - parameter and commands - block parameterization - teach-in - process data - using different pressure
More informationLCD Module with I2C / Serial Interface and Keypad Control «LCD I2C/Serial» User s Guide. Copyright 2008 IMS
LCD Module with I2C / Serial Interface and Keypad Control «LCD I2C/Serial» User s Guide Copyright 2008 IMS CONTENTS 1 INTRODUCTION... 3 2 MODULE CONNECTION... 3 2.1 I2C/Serial interface connector...4 2.2
More informationAppendix A: Data Registers
Appendix A: Data Registers Data registers can be dedicated to a specific purpose, optionally dedicated or continuously available for user data. They can be designated as Read Only or Read & Write. Data
More information6 Remote memory access protocol (normative)
6 Remote memory access protocol (normative) 6.1 General 6.1.1 Purpose The remote memory access protocol (RMAP) has been designed to support a wide range of SpaceWire applications. Its primary purpose however
More information1. Implemented CM11 protocol
1. Implemented CM11 protocol 1.1. Housecodes and Device Codes. The housecodes and device codes range from A to P and 1 to 16 respectively although they do not follow a binary sequence. The encoding format
More informationCDN Series Displays with Profibus-DP ELEN UNI-TXT (ND) protocol PARAMETRIZATION OF PROFIBUS-DP COMMUNICATION INTERFACE
CDN Series Displays with Profibus-DP ELEN UNI-TXT (ND) protocol PARAMETRIZATION OF PROFIBUS-DP COMMUNICATION INTERFACE ELEN, s.r.o. NDI Display Profibus DP UNI TXT(ND) CONTENT Page 2 of 12 1. Introduction...
More informationUser - Data Sheet: Transponder (R/W) ID DTx.C. 32 Byte of that:
R O B I D User - Data Sheet: Transponder (R/W) ID DTx.C transponder write- / readable password protected data crypto-function (data-current coding) configuration of working modes configuration of memory
More informationAsReader DeskTop UHF RFID Reader Command Reference v1.11
AsReader DeskTop UHF RFID Reader Command Reference v1.11 Asterisk, Inc. 2017-12-15 Content 1. COMMUNICATION INTERFACE SPECIFICATION... 3 2. PROTOCOL DESCRIPTION... 3 3. DATA BLOCK FORMAT... 4 3.1 COMMAND
More informationMC9S12 Address Space
MC9S12 Address Space MC9S12 has 16 address lines MC9S12 can address 2 16 distinct locations For MC9S12, each location holds one byte (eight bits) MC9S12 can address 2 16 bytes 2 16 = 65536 2 16 = 2 6 2
More informationUHF RFID Reader AsReader Box
UHF RFID Reader AsReader Box Command Reference Ver.1.14 Asterisk, Inc. Contents 1 Interface specification... 1 2 Protocol Description... 1 3 Formats of data frames... 2 3.1 Command Frame Format (From HOST)...
More informationBoot Loader. Bootloader
October 2013 Boot Loader A program that is executed upon initial power-up that typically involves a power-on self-test, locating and initializing peripheral devices, and then loading and starting an operating
More informationBNI IOL K023 BNI IOL K023. User s Guide
BNI IOL-712-000-K023 BNI IOL-714-000-K023 User s Guide 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations 2 1.3.2 Actions 2 1.3.3
More informationProgramming Manual RFID (Radio Frequency Identification) SLP-TX403R.
Programming Manual RFID (Radio Frequency Identification) Rev. 1.00 SLP-TX400R SLP-TX403R http://www.bixolon.com Table of Contents 1. Manual Information... 3 2. Basic Theory... 3 2-1 RFID Printer... 3 2-2
More informationICN12. I2C to UART Bridge, ADC,DAC and I/O
Firmware version 1.4 Introduction ICN12 I2C to UART Bridge, ADC,DAC and I/O This is an I2C to UART bridge, designed to give an extra UART to a microcontroller when only I2C is available. It is an I2C device
More informationMicro RWD MF (Mifare) Low Power Version (with auxiliary data outputs)
Data Sheet MFPROT_LP.pdf 35 Pages Last Revised 09/08/11 Micro RWD MF (Mifare) Low Power Version (with auxiliary data outputs) The MicroRWD MF LP (Low Power) module is a complete read and write solution
More informationMicro RWD MF-IC (Mifare/ICODE/ISO14443B) Reader (low power version with auxiliary outputs)
Data Sheet MF_ICBprot_030518.pdf 43 Pages Last Revised 03/05/2018 Micro RWD MF-IC (Mifare/ICODE/ISO14443B) Reader (low power version with auxiliary outputs) The MicroRWD MF-IC module is a complete contactless
More informationOptidrive VTC Modbus RTU Register Map
Application Note AN-VTC- 39 Optidrive VTC Modbus RTU Register Map Author: Ning Xu, Invertek Drives Ltd Revision: 2.21 6 September 2006 General This document details the Modbus RTU memory mapping implemented
More informationPRE32 RS232 protocol v1.21 Tomas Andersson
PRE32 RS232 protocol 2014-11-07 v1.21 Tomas Andersson Description This document describes the RS232 protocol used to control the PRE32 device. Command structure Commands are sent to the device using the
More informationF 2 MC-8L FAMILY 8-BIT MICROCONTROLLER MB89201 SERIES GETTING STARTED DEV-MB89N202-APP1 OPERATION MANUAL
Electronics Source Co., L td. Operation Manual F 2 MC-8L FAMILY 8-BIT MICROCONTROLLER MB89201 SERIES GETTING STARTED DEV-MB89N202-APP1 OPERATION MANUAL Content Introduction 3 1. Chapter 1 Hardware 1.1
More informationCustom Installation Notes: Serial programming interface and IR remote commands for Arcam D33 DAC
23425 Custom Installation Notes: Serial programming interface and IR remote commands for Arcam D33 DAC ULTRA HIGH PRECISION DIGITAL TO ANALOGUE CONVERTER D33 44.1 48 88.2 1 2 96 176.4 192 1 OPTICAL 2 1
More informationElotech Standard Protocol. for Single R8200 SC
Elotech Standard Protocol interface description / network protocol for Single R8200 SC ELOTECH Industrieelektronik GmbH Verbindungsstraße 27 D - 40723 HILDEN FON +49 2103 / 255 97 0 FAX +49 2103 / 255
More informationEye-BERT 10G and Micro 10G Software Programming Guide
Eye-BERT 10G and Micro 10G Software Programming Guide USB Driver: In order for Windows to recognize the Eye-BERT 10G / Eye-BERT Micro 10G the USB driver must first be installed, after which the Eye-BERT
More informationEXD-TEVI Economizer Controller for Tandem Compressors
Technical Bulletin EXD-TEVI is a stand-alone controller for enhanced wet vapor injection for Copeland tandem Scroll compressors in heating applications. Features EXD-TEVI Emerson solution for specified
More informationPOWERSPY POWERSPY TO PC PROTOCOL SPECIFICATION
ALCIOM 5, Parvis Robert Schuman 92370 CHAVILLE - FRANCE Tel/Fax : 01 47 09 30 51 contact@alciom.com www.alciom.com Projet : POWERSPY DOCUMENT : POWERSPY TO PC PROTOCOL SPECIFICATION REFERENCE : AL/LG/0838/003
More informationUPB US1-40 Single Rocker Wall Switch with Dimmer Firmware Specification
UPB US1-40 Single Rocker Wall Switch with Dimmer Firmware Specification V 1.0 5/18/05 Revision History Spec. Rev. Date Firmware Rev. Description 1.0 5/18/05 V2.12 Originated from US2 spec V1.9 Table of
More informationBus-FMS-Standard. Bus-FMS-Standard-Simulation User Manual. Armin Keller. fms_bus_simulation_211_manual_e. 10. February 2012
LogiCom GmbH Bus-FMS-Standard Bus-FMS-Standard-Simulation User Manual Armin Keller fms_bus_simulation_211_manual_e 10. February 2012 For this underlay and contents become the protection provided by the
More informationFACTORY AUTOMATION. MANUAL R CANopen Protocol
FACTORY AUTOMATION MANUAL R2100 - CANopen Protocol With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services
More informationTPMC x ADC, 16x/0x DAC and 8x Digital I/O. Version 1.0. User Manual. Issue May 2018
The Embedded I/O Company TPMC533 32x ADC, 16x/0x DAC and 8x Digital I/O Version 1.0 User Manual Issue 1.0.1 May 2018 TEWS TECHNOLOGIES GmbH Am Bahnhof 7 25469 Halstenbek, Germany Phone: +49 (0) 4101 4058
More informationCSE 473 Introduction to Computer Networks. Exam 1. Your name: 9/26/2013
CSE 473 Introduction to Computer Networks Jon Turner Exam 1 Your name: 9/26/2013 1. (10 points). A user in Chicago, connected to the internet via a 100 Mb/s (b=bits) connection retrieves a 250 KB (B=bytes)
More information1.1 Errors and Event list
1.1 Errors and Event list 1.1.1 State machine errors Error code Display description Full description 0x0100 EVENT OVERFLOW Too many events were entered into state machine configuration 0x0101 STATE OVERFLOW
More informationTMCC160 TMCL FIRMWARE MANUAL
motioncookie SYSTEM IN A PACKAGE motioncookie TMCC160 TMCL FIRMWARE MANUAL TMCC160 TMCL Firmware Version 2.09 2015-NOV-25 Document Revision 1.0 2015-DEC-04 The TMCL Firmware is used in combination with
More informationTPMC / 16 Channels of 16 bit D/A. Version 1.0. User Manual. Issue December 2010
The Embedded I/O Company TPMC553 32 / 16 Channels of 16 bit D/A Version 1.0 User Manual Issue 1.0.3 December 2010 TEWS TECHNOLOGIES GmbH Am Bahnhof 7 25469 Halstenbek, Germany Phone: +49 (0) 4101 4058
More informationH1PROT.PDF 14 Pages Last Revised 02/11/06. Micro RWD H1/S Protocol
Data Sheet H1PROT.PDF 14 Pages Last Revised 02/11/06 Micro RWD H1/S Protocol The MicroRWD H1/S version is a complete reader and tag acceptance solution for Hitag 1 RF transponders (including Hitag S256
More informationUHF RFID Reader VI-88C User's Manual V2.0
UHF RFID Reader VI-88C User's Manual V2.0 Content 1. COMMUNICATION INTERFACE SPECIFICATION...4 2. PROTOCOL DESCRIPTION...4 3. DATA BLOCK FORMAT...5 3.1 COMMAND DATA BLOCK...5 3.2 RESPONSE DATA BLOCK...5
More informationBV4626 General Purpose I/O. Product specification. Mar 2010 V0.a. ByVac Page 1 of 13
General Purpose I/O Product specification Mar 2010 V0.a ByVac Page 1 of 13 Contents 1. Introduction... 3 2. Features... 3 3. Physical Specification... 3 3.1. JP7... 3 3.2. Control Interface... 4 3.3. Serial
More informationType Type Type Type Type B Interface Description /
Type 202530 Type 202535 Type 202540 Type 202545 Type 202550 B 20.2530.2 Interface Description 02.03 / 00415372 Please read these operating instructions before commissioning the instrument. Keep this manual
More informationMicro RWD Quad-Tag Reader
Data Sheet RWD_QT.pdf 8 Pages Last Revised 08/05/06 Micro RWD Quad-Tag Reader The MicroRWD QT (Quad-Tag) version is a complete 125kHz reader solution for Hitag 1 (including Hitag S in Plain Memory mode),
More informationInstruction Manual. XS308 RFID tag reader/recorder on RS485 Modbus RTU 2-wire or RS232 ASCII network. Flush-fitted Simple Economic
COMITRONIC - BTI INNOVATION IS OUR DRIVING FORCE ADAPTABILITY IS OUR CULTURE Instruction Manual XS308 RF tag reader/recorder on RS485 Modbus RTU 2-wire or RS232 ASCII network Miniature access control Production
More informationAsReader Desktop Demo Reference Guide v1.2
AsReader Desktop Demo Reference Guide v1.2 Asterisk, Inc. 2018-11-5 Revision History No. Version Modified Content Date Reviser 1 1.1 Initial version 2018/10/18 Zhen Liu 2 1.2 1. The mask, tag lock, tag
More informationThe term "router" in this document refers to both routers and Layer 3 switches. Step Command Remarks. ipv6 host hostname ipv6-address
Contents Configuring IPv6 DNS 1 Overview 1 Configuring the IPv6 DNS client 1 Configuring static domain name resolution 1 Configuring dynamic domain name resolution 1 Displaying and maintaining IPv6 DNS
More informationL-force Controls EDSPLCLIB Ä.GMQä. Software Manual. Function library"canopensdodrv" for Lenze software»drive PLC Developer Studio«
EDSPLCLIB03 13384448 L-force Controls Ä.GMQä Software Manual Function library"canopensdodrv" for Lenze software»drive PLC Developer Studio«L Contents Contents 1 About this documentation.........................................................
More informationRemote Management 2.0. March 06, 2013 ENOCEAN SYSTEM SPECIFICATION. Subject to modifications. EnOcean GmbH. Phone
2.0 March 06, 2013 EnOcean GmbH Kolpingring 18a Phone +49.89.67 34 689-0 Fax +49.89.67 34 689-50 Subject to modifications EnOcean Standard REVISION HISTORY The following major modifications and improvements
More informationCOMMUNICATION MODBUS PROTOCOL
COMMUNICATION MODBUS PROTOCOL CE4DT36 CONTO D4 Pd (3-single phase) PR134 20/10/2016 Pag. 1/11 Contents 1.0 ABSTRACT... 2 2.0 DATA MESSAGE DESCRIPTION... 3 2.1 Parameters description... 3 2.2 Data format...
More informationTPMC Channel Serial Interface RS232/RS422. Version 1.0. User Manual. Issue August 2014
The Embedded I/O Company TPMC461 8 Channel Serial Interface RS232/RS422 Version 1.0 User Manual Issue 1.0.6 August 2014 TEWS TECHNOLOGIES GmbH Am Bahnhof 7 25469 Halstenbek, Germany www.tews.com Phone:
More informationConfiguring IPv6 DNS. Introduction to IPv6 DNS. Configuring the IPv6 DNS client. Configuring static domain name resolution
Contents Configuring IPv6 DNS 2 Introduction to IPv6 DNS 2 Configuring the IPv6 DNS client 2 Configuring static domain name resolution 2 Configuring dynamic domain name resolution 2 Displaying and maintaining
More informationData Communication Protocol Host Computer to FAS-A
Data Communication Protocol Host Computer to FAS-A Overview This section codifies the communication protocol between an FAS-A and a host computer. Utilizing these protocols the host computer can 1) acquire
More informationEmbedded Systems. PIC16F84A Internal Architecture. Eng. Anis Nazer First Semester
Embedded Systems PIC16F84A Internal Architecture Eng. Anis Nazer First Semester 2017-2018 Review Computer system basic components? CPU? Memory? I/O? buses? Instruction? Program? Instruction set? CISC,
More informationCOMMUNICATION MODBUS PROTOCOL
COMMUNICATION MODBUS PROTOCOL CE4DMID31 / CE4DMID21 CONTO D4 Pd MID PR123 20/10/2016 Pag. 1/9 Contents 1.0 ABSTRACT... 2 2.0 DATA MESSAGE DESCRIPTION... 3 2.1 Parameters description... 3 2.2 Data format...
More informationGeneral Monitors S5000 Modbus Specification. Order No.: MANS5000M/00. MSAsafety.com
General Monitors S5000 Modbus Specification Order No.: MANS5000M/00 MSAsafety.com General Monitors, an MSA company 26776 Simpatica Circle Lake Forest, CA 92630 A Phone: +1-949-581-4464 For your local MSA
More informationInterface Card, Interface Box, Datalogger & Interface. Bedienungsanleitung. Kommunikationsprotokoll. Operating Instructions. Communications protocol
Interface Card, Interface Box, Datalogger & Interface D GB Bedienungsanleitung Kommunikationsprotokoll Operating Instructions Communications protocol 42,0410,1318 022005 Table of contents General remarks...
More informationNXShield Interface Specifications
NXShield Advanced Development Guide v1.0 NXShield Interface Specifications Power Specs: NXShield can be powered from external power supply. Max Power Rating: 10.5 Volts DC Minimum 6.6 Volts DC needed to
More informationDS2760K Li + Battery Monitor Evaluation Kit
Li + Battery Monitor Evaluation Kit www.dalsemi.com FEATURES Demonstrates the capabilities of the DS2760 Li + Battery Monitor, including: Temperature measurement Voltage measurement Current measurement
More informationBL75R06SM 8K-bit EEPROM Contactless smart card chip
Description BL75R06SM consists of the RF-Interface, the Digital Control Unit and the 8 Kbit EEPROM. Operating distance is up to 10cm(depending on antenna geometry). The communication layer complies to
More informationBeckhoff Lightbus - PC interface card C1220
Beckhoff Lightbus - PC interface card C1220 Technical hardware description Version 4.0 Contents 2 Contents 1. Beckhoff Lightbus System Description 3 2. Hardware description of functions 6 3. Software description
More informationThe RS-485 user manual for B800 series communication
The user manual of B800 Series Rs-485 The RS-485 user manual for B800 series RS-232 inbuilt inside the main board of B800 series frequency inverter, we can effect RS-485 through fitting board externally.
More informationMODBUS APPLICATION PROTOCOL SPECIFICATION V1.1b3 CONTENTS
MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1b3 CONTENTS 1 Introduction... 2 1.1 Scope of this document... 2 2 Abbreviations... 2 3 Context... 3 4 General description... 3 4.1 Protocol description...
More informationSECTION 5 SMART PAYOUT MANUAL SET SOFTWARE IMPLEMENTATION GUIDE
SECTION 5 SMART PAYOUT MANUAL SET SOFTWARE IMPLEMENTATION GUIDE Innovative Technology assume no responsibility for errors, omissions, or damages resulting from the use of information contained within this
More information3GV M Modbus RTU Register Map
Application Note AN-ODP- 38 3GV M Modbus RTU Register Map Author: Ning Xu, Invertek Drives Ltd Revision: 2.21 15 June 2007 General This document details the Modbus RTU memory mapping implemented in Optidrive
More informationTCP Channel Serial Interface RS232/RS422. Version 1.0. User Manual. Issue August 2014
The Embedded I/O Company TCP462 4 Channel Serial Interface RS232/RS422 Version 1.0 User Manual Issue 1.0.6 August 2014 TEWS TECHNOLOGIES GmbH Am Bahnhof 7 25469 Halstenbek, Germany Phone: +49 (0) 4101
More informationTPMC Channel Serial Interface RS232/RS422. Version 1.0. User Manual. Issue August 2014
The Embedded I/O Company TPMC460 16 Channel Serial Interface RS232/RS422 Version 1.0 User Manual Issue 1.0.6 August 2014 TEWS TECHNOLOGIES GmbH Am Bahnhof 7 25469 Halstenbek, Germany www.tews.com Phone:
More informationTPMC500. Optically Isolated 32 Channel 12 Bit ADC. Version 1.1. User Manual. Issue January 2014
The Embedded I/O Company TPMC500 Optically Isolated 32 Channel 12 Bit ADC Version 1.1 User Manual Issue 1.1.9 January 2014 TEWS TECHNOLOGIES GmbH Am Bahnhof 7 25469 Halstenbek, Germany Phone: +49 (0) 4101
More informationiclass Reader (RevA) PIC 18F452/18F6621 RAM Dumper Operating Instructions
iclass Reader (RevA) PIC 18F452/18F6621 RAM Dumper Operating Instructions Proxclone.com Revision 2.0 December2015 Overview The RAM dumper circuit is used in conjunction with a HID iclass RevA reader to
More information