1 EMC CLARiiON iscsi Server Setup Guide for HP-UX P/N Revision A03 May 30, 2008 This document describes how to configure iscsi initiator ports and how to set up iscsi security on a server connected to the iscsi data ports on CX4 UltraFlex TM series, CX3 UltraScale TM series, CX series, and AX4 5 series storage systems. We recommend that you use this guide in conjunction with one of the followingguides,whichareavailableonthepowerlink website: thestorage-systemsetupguide(ax4 5serieswithNavisphereExpress, CX4 series, CX3 series, or CX series storage systems) the installation roadmap (P/N ) (AX4 5 series with Navisphere Manager, CX4 series, CX3 series, or CX series storage systems) IMPORTANT Only network interface cards (NICs) are currently supported. For more information on supported operating system revisions, driver types, or features, refer to the E-Lab Interoperability Navigator on the Powerlink website for CX4 series, CX3 series, or CX series storage systems, and the Support Matrix link on the Install page of the storage-system support website for AX4-5 series or AX series storage systems. Topics include: Before you start... 2 iscsi server setup process overview... 5 Installing NIC or HBA iscsi initiator software... 6 Assigning an IP address to a NIC or iscsi HBA... 7 Configuring access to the iscsi target devices... 8 Registering the iqn number with the storage system Preparing for CHAP security Configuring CHAP on the iscsi initiators
2 Before you start Before you use this guide to set up iscsi initiator ports on the server or to set up iscsi security (Challenge Handshake Authentication Protocol CHAP),youmust: configure the storage-system iscsi ports as described in the storage-system setup guide or the installation roadmap (storage systems with Navisphere Manager only). complete the worksheets in the storage system configuration planning guide that either shipped with your storage system or that you generated from the customized storage-system support website. For AX4-5 series, you can generate a planning guide using the Plan link on the Install page of the storage-system support website. For CX4 series, CX3 series or CX series, you can generate a planning guide using the Plan link on the storage-system support website. You should also verify that the following is true: All network hardware has been installed, including any NICs, switches, and cabling. Refer to the appropriate documentation for any components that you are installing, including switch documentation, and the configuration worksheet that you created when you installed your storage system. The storage-system iscsi ports have been configured. The latest HP-UX patches have been installed on the server. For informationonthelatestpatches,refertowww.hp.com. For more informationonchapsecurity,refertothechap security overview, page 3. Otherwise, refer to the iscsi server setup process overview, page 5. Terms used in this guide The table below lists the storage system terms used in this guide. 2 EMC CLARiiON iscsi Server Setup Guide for HP-UX
3 Table 1 Storage system models Storage system term Refers to CX4 series CX4-120, CX4-240, CX4-480, and CX4-960 storage systems CX3 series CX3 model 10 systems, CX3 model 20 systems, CX3 model 40 systems, and CX3 model 80 storage systems CX series AX4-5 series CX200, CX300 series, CX400, CX500 series, CX600, and CX700 storage systems AX4-5SC, AX4-5SCi, AX4-5, AX4-5i storage systems CHAP security overview Challenge Handshake Authentication Protocol (CHAP) is a method of authenticating iscsi users. The iscsi storage system can use CHAP to authenticate initiators and initiators can likewise authenticate targets such as the storage system.! CAUTION If you do not configure CHAP security for the storage system, any host connected to the same IP network as the storage-system iscsi portscanreadfromandwritetothestoragesystem. Ifthestorage system is on a private network, you can choose not to use CHAP security. If the storage system is on a public network, we strongly recommend that you use CHAP security. If you want to use CHAP security, you must set up and enable it on both the server and storage system before preparing LUNs or virtual disks to receive data. If you prepare disks to receive data before you set up and enable CHAP security, you lose access to the LUNs or virtual disks. While you are setting up and enabling CHAP, you may temporarily loose connectivity between the server and the storage system. CHAP has the following two variants: Initiator CHAP - Sets up accounts that iscsi initiators use to connect to targets. The target authenticates the initiator. Initiator CHAP is the primary CHAP authentication method. EMC CLARiiON iscsi Server Setup Guide for HP-UX 3
4 Navisphere Express provides Basic and Advanced initiator CHAP options. Basic CHAP specifies one secret (password) for all initiators thatlogintoagiventarget. TheAdvanced option allows you to specify a different secret for each initiator, and also allows you to set up mutual CHAP. Mutual CHAP - Applied in addition to initiator CHAP, mutual CHAP sets up an account that a target uses to connect to an initiator. The initiator authenticates the target. The HP-UX documentation uses the term uni-directional CHAP to describe initiator CHAP and bi-directional CHAP to describe mutual CHAP. 4 EMC CLARiiON iscsi Server Setup Guide for HP-UX
5 iscsi server setup process overview The following overview describes the steps required for configuring iscsi initiator ports and setting up iscsi security. Configuring iscsi initiator ports Install the network interface card (NIC) or host bus adapter (HBA) iscsi initiator software on each server with NICs or iscsi HBAs that you will connect to the storage system as described in Installing NIC or HBA iscsi initiator software,page 6. Assign an IP address for the NICs or iscsi HBAs as described in Assigning an IP address to a NIC or iscsi HBA, page 7. Configure access to the iscsi target devices as described in Configuring access to the iscsi target devices, page 8. Setting up iscsi security Prepare for setting up CHAP on the server as described in Preparing for CHAP security, page13. Configure initiator and mutual (optional) CHAP on each NIC or iscsi HBA initiator as described in Configuring CHAP on the iscsi initiators, page14. EMC CLARiiON iscsi Server Setup Guide for HP-UX 5
6 Installing NIC or HBA iscsi initiator software You must install NIC or HBA iscsi initiator software on each server with NICs or iscsi HBAs that you will connect to the storage system. Only NICs are currently supported. Downloading and installing the HP-UX iscsi initiator software 1. Open a web browser and connect to the HP-UX website: 2. Select iscsi software initiator. 3. From the HP-UX iscsi Software Initiator page, select HP-UX iscsi software initiator. The Product details and specifications page opens. 4. Download the documentation listed under the Documentation heading. You may need to refer to these documents when you download and install the initiator software. 5. Select Receive for Free and follow the instructions on the site to download the initiator software. 6. Install the initiator software. 6 EMC CLARiiON iscsi Server Setup Guide for HP-UX
7 Assigning an IP address to a NIC or iscsi HBA Assign an IP address to each NIC or iscsi HBA in the server that will be connected to the storagesystem. For the NIC or iscsi HBA IP addresses, refer to the iscsi target and initiator port network information worksheet, which you should have completed when you planned your configuration using the Administration Worksheet and the configuration and planning guide. Only NICs are currently supported. Assigning an IP address to a NIC in an HP-UX server 1. At the HP-UX server, log in as superuser (root). 2. Atthecommandprompt(#)inthehpterm or xterm window, open the sam utility by entering sam. 3. Select Networking and Communications. 4. Select Network Interface Cards. 5. Select the Ethernet card you want to configure. 6. From the main menu, select Actions > Configure. 7. Enter the IP address and select OK. EMC CLARiiON iscsi Server Setup Guide for HP-UX 7
8 Configuring access to the iscsi target devices Before an iscsi initiator can send data to or receive data from the storage system, you must configure the network parameters for the NIC initiators so that they can connect to the storage-system storage processor (SP) iscsi targets. To configure access to the iscsi target devices: 1. Verify that you are logged in as superuser (root). 2. Add the path for the iscsiutil and other iscsi executables to the root path as follows: #PATH=$PATH:/opt/iscsi/bin 3. Verify the iscsi initiator name by executing the iscsiutil -l command. The iscsi software initiator configures a default initiator name in an iscsi Qualified Name (iqn) format, for example, iqn com.hp:hpfcs If you would like to change the default iscsi initiator name or reconfigure the name to an IEEE EUI-64 (eui) format, continue to the next step; otherwise, skip to step Configure the default iscsi initiator name. # iscsiutil [iscsi-device-file] -i-niscsi-initiator-name For more information on iqn and eui formats, refer to the HP-UX iscsi software initiator guide. where: iscsi-device-file is the iscsi device path, /dev/iscsi, and is optional if you include the -i or -N switches in the command. -i configures iscsi initiator information. 8 EMC CLARiiON iscsi Server Setup Guide for HP-UX
9 -N is the initiator name. When preceded by the -i switch, it requires the iscsi initiator name. The first 256 characters of the name string arestoredintheiscsipersistentinformation. iscsi-initiator-name is the initiator name you have chosen, in iqn or eui format. 5. Verify the new iscsi initiator name. iscsiutil -l 6. For each iscsi target device you will statically identify, store thetargetdeviceinformationinthekernelregistry. Addone(or several) discovery target(s). # iscsiutil [/dev/iscsi] -a -I ip-address hostname [-P tcp-port] [-M portal-grp-tag] where: -a adds a discovery target address into iscsi persistent information. You can add discovery target addresses only with this option. -I is the option that requires the IP address or the hostname of the discovery target portal address. ip-address hostname is the IP address or hostname component of the target network portal. -P tcp-port is the listening TCP port component of the discovery target network portal (optional). The default iscsi TCP port number is M portal-grp-tag is the target portal group tag (optional). The default target portal group tag for discovery targets is 1. For example, iscsiutil -a -I or, if you specify the hostname, iscsiutil -a -I target.hp.com. EMC CLARiiON iscsi Server Setup Guide for HP-UX 9
10 If an iscsi TCP port used by the discovery target is different than the default iscsi port of 3260, you must specify the default TCP port used by the discovery target; for example, iscsiutil -a -I P 5001 or iscsiutil -a -I target.hp.com -P Verify the discovery target(s) that you have configured. iscsiutil -p -D 8. To discover the operational target devices, enter /usr/sbin/ioscan -H To create the device files for the targets, enter /usr/sbin/insf -H To display operational targets, enter # iscsiutil -p -O. 10 EMC CLARiiON iscsi Server Setup Guide for HP-UX
11 Registering the iqn number with the storage system This section describes how to register the iqn number with the storage system using the Navisphere Server Utility or the Navisphere Host Agent (storage systems with Navisphere Manager only). Registering the iqn number using the Navisphere Host Agent (storage systems with Navisphere Manager only) If you have the host agent installed, use it to register the iqn number. 1. Start the Navisphere Host Agent. /sbin/init.d/agent start 2. Reboot the server. Registering the iqn number using the Navisphere Server Utility If you have the server utility installed, use it to register the iqn number. Starting the Navisphere Server Utility on an HP-UX server 1. Open an hpterm window. 2. Navigate to the Navisphere bin directory and run the server utility: /opt/navisphere/bin/naviserverutil Registering the server using the Navisphere Server Utility for HP-UX If the host agent is running, stop the host agent service. 1. In the server utility, enter 1 to select Update Server Information. The utility automatically scans for connected storage systems, and displays a list of the ones it finds. 2. In the server utility, enter u toregistertheserverwitheachstorage system the utility found. EMC CLARiiON iscsi Server Setup Guide for HP-UX 11
12 The utility sends the server s name and IP address to each storage system. Once the server has storage on the storage system, the utility also sends the HP-UX device name and volume or file system information for each virtual disk or LUN in the storage system that the server sees. 3. Enter c (cancel) to stop the utility. 4. If you stopped the host agent, restart it. 5. Reboot the server. 12 EMC CLARiiON iscsi Server Setup Guide for HP-UX
13 Preparing for CHAP security To prepare for using CHAP security, you must have done the following: Completed the CHAP worksheets in the chapter on iscsi configuration in the appropriate configuration and planning guide that either shipped with your storage system or that you generated from the customized storage-system support website. EMC CLARiiON iscsi Server Setup Guide for HP-UX 13
14 Configuring CHAP on the iscsi initiators Before configuring CHAP security on iscsi initiators, verify that you have completed the steps listed in the previous section, Preparing for CHAP security. The HP-UX documentation uses the term uni-directional CHAP to describe initiator CHAP and bi-directional CHAP to describe mutual CHAP. Navisphere Express refers to initiator CHAP as basic CHAP. Configuring initiator CHAP on NIC initiators in a HP UX server! CAUTION You must enable CHAP security for the NIC or before you can configure CHAP on the storage system. While you are setting up and enabling CHAP, you may temporarily loose connectivity between theserverandthestoragesystem. To configure initiator CHAP: 1. Verify that you are logged in as superuser (root). 2. Configure one of the following initiator CHAP authentication methods: Global # iscsiutil -u -H CHAP_UNI Discovery target address # iscsiutil -u -H CHAP_UNI -I M 3 Operational target # iscsiutil -u -H CHAP_UNI -T iqn com.hp.stor:iscsi Operational target address # iscsiutil -u -H CHAP_UNI -T iqn com.hp.stor:iscsi -I P M 1 3. Configure the CHAP initiator username. 14 EMC CLARiiON iscsi Server Setup Guide for HP-UX
15 # iscsiutil -u -N chap-initiator-name [-T target-name] [-I ip-address] [-P tcp-port] [-M portal-grp-tag] If you did not configure the CHAP initiator name, the utility will use the iscsi initiator name. For example: Global # iscsiutil -u -N mychapusername Discovery target address # iscsiutil -u -N mychapusername -I M 2 Operational target # iscsiutil -u -N mychapusername -T iqn com.hp.stor:iscsi Operational target address # iscsiutil -u -N mychapusername -T iqn com.hp.stor:iscsi -I P M 1 4. Configure the initiator CHAP secret. # iscsiutil -u -W chap-initiator-secret [-T target-name] [-I ip-address] [-P tcp-port] [-M portal-grp-tag] You can enter the secret in two forms ASCII and hexadecimal. In the hexadecimal form, the number of hex digits must be even. For example: Global # iscsiutil -u -W mychapsecret or # iscsiutil -u -W 0xed345ba678dfffe54e35666fa2c3c3 Discovery target address # iscsiutil -u -W mychapsecret -I M 1 Operational target # iscsiutil -u -W mychapsecret -T iqn com.hp.stor:iscsi Operational target address # iscsiutil -u -W mychapsecret -T iqn com.hp.stor:iscsi -I P M 1 5. Enter one of the following commands to verify the initiator CHAP parameters you configured: EMC CLARiiON iscsi Server Setup Guide for HP-UX 15
16 All global targets # iscsiutil -l All discovery targets # iscsiutil -pd All operational targets # iscsiutil -po A particular operational target # iscsiutil -p -T target-name 6. When the output is displayed, verify the authentication method, CHAP method, initiator CHAP name, and CHAP secret. Configuring mutual (target) CHAP on NIC initiators on an HP-UX server! CAUTION You must enable CHAP security for the NIC or before you can configure CHAP on the storage system. While you are setting up and enabling CHAP, you may temporarily loose connectivity between theserverandthestoragesystem. Setting up mutual CHAP requires a RADIUS server. For more information on a RADIUS server, refer to the HP-UX documentation. 1. Verify that you are logged in as superuser (root). 2. Follow the same procedures to configure the mutual CHAP usernameandsecretasyoudidforinitiatorchap. 3. Configure the Network Access Server (NAS) and RADIUS server parameters. # iscsiutil -u -R nas-hostname nas-secret radius-server-hostname where: -u configures initiator and target CHAP authentication parameters. -R allows you to specify the nas-hostname, nas-secret, radius-server-hostname arguments. Nas-hostname is the IP address or hostname of the NAS. NAS operates as a client of a RADIUS server, 16 EMC CLARiiON iscsi Server Setup Guide for HP-UX
17 which is the host that runs the iradd daemon. Nas-secret is the secret for the iradd daemon. You must configure this secret as the NAS secret of iradd on the RADIUS server. This secret is used by iradd to authenticate the RADIUS server. Radius-server-hostname is the IP address or hostname of the RADIUS server. For more information on NAS and RADIUS servers, refer to the appropriate HP-UX software initiator documentation. 4. Add a RADIUS client through the Access Devices menu on the RADIUSserver.Besuretoenterthenas-hostname in the Name field and the nas-secret in the Shared Secret field. 5. Add a user to the RADIUS server with the target CHAP username and secret. 6. Configure mutual CHAP. # iscsiutil -u -H chap-authentication-type [-T target-name] [-I ip-address>] [-P tcp-port] [-M portal-grp-tag] Example authentication methods for configuring mutual CHAP: Global # iscsiutil -u -H CHAP_BI Discovery target address # iscsiutil -u -H CHAP_BI -I M 3 Operational target # iscsiutil -u -H CHAP_BI -T iqn com.hp.stor:iscsi Operational target address # iscsiutil -u -H CHAP_BI -T iqn com.hp.stor:iscsi -I P M 1 7. Enter one of the following commands to verify the mutual CHAP parameters you configured: All global targets # iscsiutil -l All discovery targets # iscsiutil -pd All operational targets # iscsiutil -po A particular operational target # iscsiutil -p -T target-name 8. When the output is displayed, verify the authentication method, CHAP method, initiator CHAP name, CHAP secret, NAS hostname, NASsecret,andRADIUSserverhostname. EMC CLARiiON iscsi Server Setup Guide for HP-UX 17
18 9. Start the iradd (iscsi CHAP) daemon. #iradd Once the iradd daemon starts, it will automatically start every time the system reboots. 18 EMC CLARiiON iscsi Server Setup Guide for HP-UX
19 Copyright 2008 EMC Corporation. All Rights Reserved. EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. THE INFORMATION IN THIS PUBLICATION IS PROVIDED "AS IS." EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. For the most up-to-date listing of EMC product names, see EMC Corporation Trademarks on EMC.com. All other trademarks mentioned herein are the property of their respective owners. EMC CLARiiON iscsi Server Setup Guide for HP-UX 19
EMC CLARiiON iscsi Server Setup Guide for VMware ESX Server 3i and 3.x Hosts
EMC CLARiiON iscsi Server Setup Guide for VMware ESX Server 3i and 3.x Hosts P/N 300 003 807, Revision A06 May 30, 2008 This document describes how to configure iscsi initiator ports and how to set up
More informationThe Contents and Structure of this Manual. This document is composed of the following ten chapters.
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationEMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N REV A05
EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N 300-002-038 REV A05 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2004-2006
More informationRelease Notes P/N REV A03 January 3, 2006
Sun StorEdge Traffic Manager for CLARiiON Release Notes P/N 300-002-978 REV A03 January 3, 2006 These release notes contain supplemental information about Sun StorEdge Traffic Manager for CLARiiON storage
More informationEMC SAN Copy Command Line Interfaces
EMC SAN Copy Command Line Interfaces REFERENCE P/N 069001189 REV A13 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2006-2008 EMC Corporation. All
More informationRelease Notes P/N REV A01 February 23, 2006
EMC AX-Series Navisphere SP Agent Version 6.20.0.3.12 for FLARE OE 02.20.yyy Release Notes P/N 300-003-516 REV A01 February 23, 2006 These release notes contain supplemental information about EMC Navisphere
More informationDell EMC Unity Family
Dell EMC Unity Family Version 4.2 Configuring Hosts to Access Fibre Channel (FC) or iscsi Storage 302-002-568 REV 03 Copyright 2016-2017 Dell Inc. or its subsidiaries. All rights reserved. Published July
More informationDisk and FLARE OE Matrix P/N REV A17 February 22, 2011
EMC CX4 Series Storage Systems Disk and FLARE OE Matrix P/N 300-007-437 REV A17 February 22, 2011 To function properly, disks in an EMC CLARiiON system require that each storage processor run minimum revisions
More informationEMC ControlCenter Navisphere Security ADMINISTRATOR S GUIDE. Version 6.X P/N REV A04
EMC ControlCenter Navisphere Security Version 6.X ADMINISTRATOR S GUIDE P/N 069001124 REV A04 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 (800) 424-EMC2 http://www.emc.com Copyright
More informationTechnical Note P/N REV A01 November 24, 2008
AIX Native MPIO for CLARiiON Technical Note P/N 300-008-486 REV A01 November 24, 2008 This technical note contains supplemental information about AIX Native MPIO for CLARiiON storage systems. Technical
More informationAX150-Series Upgrading FLARE Operating Environment Software March 28, 2006
AX150-Series Upgrading FLARE Operating Environment Software March 28, 2006 This document describes how to upgrade your AX150 FLARE Operating Environment (OE) - the storage-system software that includes
More informationEMC Celerra NS-120 System (Dual Blade) Installation Guide
EMC Celerra NS- System (Dual Blade) Installation Guide P/N -7-88 Rev A EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without
More informationDrive and FLARE OE Matrix
EMC CX4 Series Storage Systems and FLARE OE Matrix P/ N 300-007-437 To function properly, drives in an EMC CLARiiON system require that each storage processor run minimum s of the FLARE Operating Environment
More informationEMC SAN Copy. Command Line Interface (CLI) Reference P/N REV A15
EMC SAN Copy Command Line Interface (CLI) Reference P/N 069001189 REV A15 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2006-2010 EMC Corporation.
More informationOracle Enterprise Manager Ops Center E Introduction
Oracle Enterprise Manager Ops Center Discover an Oracle ZFS Storage Appliance and Configure Storage Libraries 12c Release 2 (12.2.2.0.0) E40770-03 December 2014 This guide provides an end-to-end example
More informationRelease Notes P/N Rev A02
EMC PowerPath for Windows Version 4.6 and Point Releases Release Notes P/N 300-003-931 Rev A02 November 27, 2006 These release notes contain information about features, system requirements, known problems,
More informationDisk and FLARE OE Matrix PN
EMC Series Storage Systems Disk and FLARE OE Matrix PN 300-006-162 To function properly, serial advanced technology attachment (SATA) or serial attached SCSI (SAS) disks in an EMC series storage system
More informationEMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA
EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA Version 4.0 Configuring Hosts to Access VMware Datastores P/N 302-002-569 REV 01 Copyright 2016 EMC Corporation. All rights reserved.
More informationTerminology. This document uses the following terms:
CX4 Architecture for NS Series Connecting a CX4-48 Storage System in a Fibre Channel Direct or Switch Configuration with a Microsoft Windows Server with Native Multipath Failover December 6, 28 If you
More informationEMC CLARiiON CX3-20f Setup Guide P/N REV. A02
EMC CLRiiON CX3-20f Setup Guide P/N 300-004-207 REV. 02 Notice Copyright 2006-2007 EMC Corporation. ll rights reserved. Published July, 2007 EMC believes the information in this publication is accurate
More informationEMC SAN Copy Command Line Interface P/N REV A14 EMC Corporation Corporate Headquarters: Hopkinton, MA
EMC SAN Copy Command Line Interface P/N 069001189 REV A14 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2006-2009 EMC Corporation. All rights reserved.
More informationRelease Notes P/N REV A01 August 11, 2010
EMC Unisphere Analyzer Version 1.0.0 Release Notes P/N 300-011-113 REV A01 August 11, 2010 These release notes contain supplemental information about EMC Unisphere Analyzer, version 1.0.0. Topics include:
More informationFlexNAS/NetServ as iscsi Target
FlexNAS/NetServ as iscsi Target Revision History Version Comments V.0 First Edition. Contents What is iscsi...... Add iscsi target on NAStorage.......... ~ Connect to iscsi target (Windows 7)..... 5 ~
More informationRestoring an SP Boot Image
AX100-Series Restoring an SP Boot Image Revision A01 June 9, 2004 This document explains how to restore an SP s boot image. Read it when an SP does not start properly and its fault light blinks four times
More informationCLARiiON CX3-40 Setup Guide P/N REV. A03
CLRiiN CX3-40 Setup Guide P/N 300-003-512 REV. 03 Notice Copyright 2006 EMC Corporation. ll rights reserved. Published ugust, 2006 EMC believes the information in this publication is accurate as of its
More informationEMC Solutions for Microsoft Exchange 2007 NS Series iscsi
EMC Solutions for Microsoft Exchange 2007 NS Series iscsi Applied Technology Abstract This white paper presents the latest storage configuration guidelines for Microsoft Exchange 2007 on the Celerra NS
More informationEMC CLARiiON Server Support Products for Windows Servers Installation Guide
EMC CLARiiON Server Support Products for Windows Servers Installation Guide P/N 300 002 038, Revision A14 October 3, 2008 This guide describes how to install and remove the EMC Navisphere Host Agent, Navisphere
More informationInstalling PowerPath. Invisible Body Tag
Invisible Body Tag 1 Installing PowerPath This chapter describes procedures to install and upgrade EMC PowerPath software on a Windows host. This chapter includes the following sections: Before you install...
More informationEMC DiskXtender for Windows and EMC RecoverPoint Interoperability
Applied Technology Abstract This white paper explains how the combination of EMC DiskXtender for Windows and EMC RecoverPoint can be used to implement a solution that offers efficient storage management,
More informationEMC DiskXtender File System Manager for UNIX/Linux Release 3.5 SP1 Console Client for Microsoft Windows
EMC DiskXtender File System Manager for UNIX/Linux Release 3.5 SP1 Console Client for Microsoft Windows P/N 300-012-249 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000
More informationEMC CLARiiON Server Support Products for HP-UX Servers Installation Guide
EMC CLARiiON Server Support Products for HP-UX Servers Installation Guide P/N 300 002 043, Revision A11 February 21, 2008 This guide describes how to install and remove the EMC Navisphere Host Agent, Navisphere
More informationDisk and OE Matrix. EMC VNXe 3200 Series Storage Systems. VNXe 3200 series storage systems
EMC VNXe 3200 Series Storage Systems Disk and OE Matrix To function properly, disks in an EMC VNXe 3200 system require that each storage processor run minimum revisions of the Operating Environment (OE).
More informationEMC Celerra NS-120 System (Single Blade) Installation Guide
EMC Celerra NS- System (Single Blade) Installation Guide P/N 3-7-88 Rev A4 EMC believes the information in this publication is accurate as of its publication date. The information is subject to change
More informationEMC DiskXtender File System Manager for UNIX/Linux Release 3.5 Console Client for Microsoft Windows
EMC DiskXtender File System Manager for UNIX/Linux Release 3.5 Console Client for Microsoft Windows Installation Guide P/N 300-009-578 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103
More informationDisk and OE Matrix. EMC VNXe Series. Storage Systems
EMC VNXe Series Storage Systems Disk and OE Matrix P/N 300-012-418 REV 06 June 25, 2013 To function properly, disks in an EMC VNXe system require that each storage processor run minimum revisions of the
More informationEMC Secure Remote Support Device Client for Symmetrix Release 2.00
EMC Secure Remote Support Device Client for Symmetrix Release 2.00 Support Document P/N 300-012-112 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright
More informationEMC CLARiiON Server Support Products for AIX Server Installation Guide
EMC CLARiiON Server Support Products for AIX Server Installation Guide P/N 300 002 044, Revision A08 January 16, 2007 This guide describes how to install and remove the Navisphere Host Agent, Navisphere
More informationVirtual Exchange 2007 within a VMware ESX datastore VMDK file replicated
EMC Solutions for Microsoft Exchange 2007 Virtual Exchange 2007 in a VMware ESX Datastore with a VMDK File Replicated Virtual Exchange 2007 within a VMware ESX datastore VMDK file replicated EMC Commercial
More informationExchange 2003 Archiving for Operational Efficiency
Exchange 2003 Archiving for Operational Efficiency Enabled by EmailXtender Reference Architecture EMC Global Solutions Operations EMC Corporation Corporate Headquarters Hopkinton MA 01748-9103 1.508.435.1000
More informationDisk and OE Matrix. EMC VNXe Series Storage Systems. VNXe series storage systems
EMC VNXe Series Storage Systems Disk and OE Matrix P/N 300-012-418 To function properly, disks in an EMC VNXe system require that each storage processor run minimum s of the Operating Environment (OE).
More informationService Description Remote Yearly Maintenance of a Dell EMC Storage Array Environment
Service Description Remote early Maintenance of a Dell EMC Storage Array Environment Service SKUs See Appendix A for further information on T1, T2 and T3 Standard Maintenance. Service Overview This service
More informationDell PowerVault MD3800i and MD3820i Series Storage Arrays Deployment Guide
Dell PowerVault MD3800i and MD3820i Series Storage Arrays Deployment Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:
More informationData Migration from Dell PS Series or PowerVault MD3 to Dell EMC SC Series Storage using Thin Import
Data Migration from Dell PS Series or PowerVault MD3 to Dell EMC SC Series Storage using Thin Import Abstract The Thin Import feature of Dell Storage Center Operating System offers solutions for data migration
More informationiscsi Boot from SAN with Dell PS Series
iscsi Boot from SAN with Dell PS Series For Dell PowerEdge 13th generation servers Dell Storage Engineering September 2016 A Dell Best Practices Guide Revisions Date November 2012 September 2016 Description
More informationCisco UCS Virtual Interface Card Drivers for Windows Installation Guide
Cisco UCS Virtual Interface Card Drivers for Windows Installation Guide First Published: 2011-09-06 Last Modified: 2015-09-01 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA
More informationVMware Site Recovery Manager with EMC CLARiiON CX3 and MirrorView/S
VMware Site Recovery Manager with EMC CLARiiON CX3 and MirrorView/S Implementation Guide EMC Global Solutions Centers EMC Corporation Corporate Headquarters Hopkinton MA 01748-9103 1.508.435.1000 www.emc.com
More informationDell EMC SAN Storage with Video Management Systems
Dell EMC SAN Storage with Video Management Systems Surveillance October 2018 H14824.3 Configuration Best Practices Guide Abstract The purpose of this guide is to provide configuration instructions for
More informationChanging default password of root user for idrac9 by using Dell EMC License Manager
Changing default password of root user for idrac9 by using Dell EMC License Manager This technical white paper describes how to change the default password of root user on Dell EMC idrac9. Dell EMC Engineering
More informationPRACTICE CONSIDERATIONS FOR DELL/EMC CX3 FC/iSCSI STORAGE SYSTEMS
Third-party information provided to you courtesy of Dell. PRACTICE CONSIDERATIONS FOR DELL/EMC CX3 FC/iSCSI STORAGE SYSTEMS BEST PRACTICES PLANNING Abstract This white paper discusses practice considerations
More informationService Description: Dell EMC Maintenance Service Standard
Dell Services Service Description: Dell EMC Maintenance Service Standard Service SKUs See Appendix A for further information on T1, T2 and T3 Standard Maintenance. Service Overview This service provides
More informationEMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA
EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA Configuring Hosts to Access NFS File Systems 302-002-567 REV 01 Copyright 2016 EMC Corporation. All rights reserved. Published in the
More informationDell PowerVault MD3860i Series Storage Arrays Deployment Guide
Dell PowerVault MD3860i Series Storage Arrays Deployment Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION
More informationInstallation Guide. Tandberg Data DPS1000 Series Model: DPS1100 and DPS1200, Release: 1.3
Installation Guide Tandberg Data DPS1000 Series Model: DPS1100 and DPS1200, Release: 1.3 Contents Preface.......................................................................v About this guide..............................................................
More informationDell Storage Center OS Version 7 Software Update Guide
Dell Storage Center OS Version 7 Software Update Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates
More informationEMC SourceOne Discovery Manager Version 6.7
EMC SourceOne Discovery Manager Version 6.7 Installation and Administration Guide 300-012-743 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright
More informationTechnical Brief: Titan & Alacritech iscsi Accelerator on Microsoft Windows
Technical Brief: Titan & Alacritech iscsi Accelerator on Microsoft Windows Abstract In today s information age, enterprise business processing & information systems are growing at an incredibly fast pace
More informationWindows Host Utilities Installation and Setup Guide
IBM System Storage N series Windows Host Utilities 6.0.1 Installation and Setup Guide GC52-1295-06 Table of Contents 3 Contents Preface... 7 Supported features... 7 Websites... 7 Getting information,
More informationDell PowerVault MD3600i and MD3620i Storage Arrays. Deployment Guide
Dell PowerVault MD3600i and MD3620i Storage Arrays Deployment Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:
More informationEMC Symmetrix with VERITAS Dynamic Multi-pathing (DMP)
EMC Symmetrix with VERITAS Dynamic Multi-pathing (DMP) Best Practices Planning Abstract This white paper provides best practices for configuring VERITAS Dynamic Multi-pathing (DMP) in an EMC Symmetrix
More informationCitrix XenServer with Dell SC Series Storage Configuration and Deployment
Citrix XenServer with Dell SC Series Storage Configuration and Deployment Dell Storage Engineering January 2017 A Dell EMC Deployment and Configuration Guide Revisions Date January 2016 Description Initial
More informationDell PowerVault MD3600i and MD3620i Storage Arrays. Deployment Guide
Dell PowerVault MD3600i and MD3620i Storage Arrays Deployment Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:
More informationIBM TotalStorage DS300 and DS400 Quick Installation Guide
IBM TotalStorage DS300 and DS400 Quick Installation Guide Before using this information and the product it supports, read the IBM Statement of Limited Warranty in the IBM TotalStorage DS300 and DS400 Warranty
More informationEMC VNXe Series. Configuring Hosts to Access NFS File Systems. Version 3.1 P/N REV. 03
EMC VNXe Series Version 3.1 Configuring Hosts to Access NFS File Systems P/N 302-000-190 REV. 03 Copyright 2014-2015 EMC Corporation. All rights reserved. Published in USA. Published June, 2015 EMC believes
More informationEMC Documentum Process Engine
EMC Documentum Process Engine Version 6.5 Installation Guide P/N 300 007 522 A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748 9103 1 508 435 1000 www.emc.com Copyright 2004 2008 EMC Corporation.
More informationEMC Voyence Integration Adaptor
EMC Voyence Integration Adaptor Version 2.0.0 EMC SMARTS P/N 300-007-379 REV A03 EMC Corporation Corporate Headquarters Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com COPYRIGHT Copyright 2008 EMC
More informationEmulex Drivers Version 10.6 for Windows. Quick Installation Manual
Emulex Drivers Version 10.6 for Windows Quick Installation Manual Connect Monitor Manage 2 Copyright 2003-2015 Emulex. All rights reserved worldwide. No part of this document may be reproduced by any means
More informationManaging the SSL Certificate for the ESRS HTTPS Listener Service Technical Notes P/N Rev 01 July, 2012
Managing the SSL Certificate for the ESRS HTTPS Listener Service Technical Notes P/N 300-013-818 Rev 01 July, 2012 This document contains information on these topics: Introduction... 2 Terminology... 2
More informationBoot and Network Configuration Deployment using Server Template with Dell EMC OpenManage Essentials (OME)
Boot and Network Configuration Deployment using Server Template with Dell EMC OpenManage Essentials (OME) Dell EMC Engineering February 2018 A Dell EMC Technical White Paper Revisions Date August 2017
More informationSetting Up the DR Series System as a CIFS, NFS, or VTL Target on Networker Technical White Paper
Setting Up the DR Series System as a CIFS, NFS, or VTL Target on Networker 8.2.1 Technical White Paper Quest Engineering October 2017 2017 Quest Software Inc. ALL RIGHTS RESERVED. THIS WHITE PAPER IS FOR
More informationDell EMC Ready Solution for VMware vcloud NFV 3.0 OpenStack Edition Platform
Dell EMC Ready Solution for VMware vcloud NFV 3.0 OpenStack Edition Platform Deployment Automation Operations Guide for VMware NFV 3.0 with VMware Integrated OpenStack 5.0 with Kubernetes Dell Engineering
More informationQLogic iscsi Boot for HP FlexFabric Adapters User Guide
QLogic iscsi Boot for HP FlexFabric Adapters User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in
More informationDisk and OE Matrix. EMC VNX5100 and VNX5300 Series Storage Systems P/N
EMC and Series Storage Systems and OE Matrix P/N 300-012-417 To function properly, disks in an EMC VNX system require that each storage processor run minimum s of the EMC VNX Operating Environment (VNX
More informationEMC Celerra Manager Makes Customizing Storage Pool Layouts Easy. Applied Technology
EMC Celerra Manager Makes Customizing Storage Pool Layouts Easy Applied Technology Abstract This white paper highlights a new EMC Celerra feature that simplifies the process of creating specific custom
More informationEMC Solutions Enabler Symmetrix Device Masking CLI PRODUCT GUIDE. Version 6.0 P/N REV A06
EMC Solutions Enabler Symmetrix Device Masking CLI Version 6.0 PRODUCT GUIDE P/N 300-000-875 REV A06 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright
More informationVMware ESXi Host Configuration
VMware ESXi 5.5 6.5 Host Configuration Rapid EqualLogic Configuration Series Implementation Guide September 2017 Revisions Date April 2012 Status Initial release September 2012 Updates for VMware ESXi
More informationDell/EMC CX3 Series Oracle RAC 10g Reference Architecture Guide
White Paper Third-party Information Provided to You Courtesy of Dell Dell/EMC CX3 Series Oracle RAC 10g Reference Architecture Guide Abstract This document provides an overview of the architecture of the
More informationInstallation Guide V1.1
Installation Guide V1.1 The information contained in this manual is the licensed property of Fujitsu Software Technology Corporation. Use of the information contained herein is restricted to the terms
More informationRelease Notes P/N REV 04 March 28, 2013
EMC VNX Event Enabler Version 5.1.0.0 Release Notes P/N 300-013-478 REV 04 March 28, 2013 This document provides information about the latest release of EMC VNX Event Enabler software and related documentation.
More informationEMC Backup and Recovery for Microsoft Exchange 2007 SP1. Enabled by EMC CLARiiON CX4-120, Replication Manager, and VMware ESX Server 3.
EMC Backup and Recovery for Microsoft Exchange 2007 SP1 Enabled by EMC CLARiiON CX4-120, Replication Manager, and VMware ESX Server 3.5 using iscsi Reference Architecture Copyright 2009 EMC Corporation.
More informationEMC CLARiiON CX3-40. Reference Architecture. Enterprise Solutions for Microsoft Exchange 2007
Enterprise Solutions for Microsoft Exchange 2007 EMC CLARiiON CX3-40 Metropolitan Exchange Recovery (MER) for Exchange Server Enabled by MirrorView/S and Replication Manager Reference Architecture EMC
More informationEMC CLARiiON CX3 Series FCP
EMC Solutions for Microsoft SQL Server 2005 on Windows 2008 EMC CLARiiON CX3 Series FCP EMC Global Solutions 42 South Street Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com www.emc.com Copyright 2008
More informationClearCube Virtualization. Deployment Guide. ClearCube Technology, Inc.
ClearCube Virtualization Deployment Guide ClearCube Technology, Inc. Copyright 2006, 2007, ClearCube Technology, Inc. All rights reserved. Under copyright laws, this publication may not be reproduced or
More informationEMC CLARiiON CX3-40. Reference Architecture. Enterprise Solutions for Microsoft Exchange Enabled by MirrorView/S
Enterprise Solutions for Microsoft Exchange 2007 EMC CLARiiON CX3-40 Metropolitan Exchange Recovery (MER) for Exchange in a VMware Environment Enabled by MirrorView/S Reference Architecture EMC Global
More informationWHITE PAPER Citrix XenServer and EMC CLARiiON CX4 Series Citrix XenServer and EMC CLARiiON CX4 Series Configuration Guide
WHITE PAPER Citrix XenServer and EMC CLARiiON CX4 Series Citrix XenServer and EMC CLARiiON CX4 Series Configuration Guide www.citrix.com Contents Introduction...4 Citrix XenServer for Enterprise ready
More informationIntegration Guide. SafeNet Authentication Service. Strong Authentication for Juniper Networks SSL VPN
SafeNet Authentication Service Integration Guide Technical Manual Template Release 1.0, PN: 000-000000-000, Rev. A, March 2013, Copyright 2013 SafeNet, Inc. All rights reserved. 1 Document Information
More informationSTRM Log Manager Administration Guide
Security Threat Response Manager STRM Log Manager Administration Guide Release 2010.0 Juniper Networks, Inc. 1194 North Mathilda Avenue Sunnyvale, CA 94089 USA 408-745-2000 www.juniper.net Published: 2011-10-10
More informationEMC Documentum Archive Services for SharePoint
EMC Documentum Archive Services for SharePoint Version 5.3 SP5 User Guide P/N 300-005-749-A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright
More informationService Description Proactive Maintenance Service
Service Description Proactive Maintenance Service Service Overview Proactive Maintenance provides Dell customers with a maintenance event (the Service or Services ) on Supported Products as set forth more
More informationConfiguring and Managing Virtual Storage
Configuring and Managing Virtual Storage Module 6 You Are Here Course Introduction Introduction to Virtualization Creating Virtual Machines VMware vcenter Server Configuring and Managing Virtual Networks
More informationEMC SourceOne Discovery Manager Version 6.5
EMC SourceOne Discovery Manager Version 6.5 Installation and Administration Guide 300-008-569 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright
More informationEMC CLARiiON CX3-80 EMC Metropolitan Recovery for SQL Server 2005 Enabled by Replication Manager and MirrorView/S
Enterprise Solutions for Microsoft SQL Server 2005 EMC CLARiiON CX3-80 EMC Metropolitan Recovery for SQL Server 2005 Enabled by Replication Manager and MirrorView/S Reference Architecture EMC Global Solutions
More informationSoftware Update C.09.xx Release Notes for the HP Procurve Switches 1600M, 2400M, 2424M, 4000M, and 8000M
Software Update C.09.xx Release Notes for the HP Procurve Switches 1600M, 2400M, 2424M, 4000M, and 8000M Topics: TACACS+ Authentication for Centralized Control of Switch Access Security (page 7) CDP (page
More informationEmulex Drivers Version 10.2 for Windows
Emulex Drivers Version 10.2 for Windows Quick Installation Manual Emulex Connects Servers, Storage and People 2 Copyright 2003-2014 Emulex. All rights reserved worldwide. No part of this document may be
More informationINTEROPERABILITY OF AVAMAR AND DISKXTENDER FOR WINDOWS
TECHNICAL NOTES INTEROPERABILITY OF AVAMAR AND DISKXTENDER FOR WINDOWS ALL PRODUCT VERSIONS TECHNICAL NOTE P/N 300-007-585 REV A03 AUGUST 24, 2009 Table of Contents Introduction......................................................
More informationChanging unique password of root user for idrac9 by using Dell EMC License Manager
Changing unique password of root user for idrac9 by using Dell EMC License Manager This technical white paper describes how to change the default password of a root user on idrac9. Dell EMC Engineering
More informationEMC NetWorker Module for SnapImage Release 2.0 Microsoft Windows Version
EMC NetWorker Module for SnapImage Release 2.0 Microsoft Windows Version Installation and Administration Guide P/N 300-007-130 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000
More informationHP OpenVMS Software-Based iscsi Initiator Technology Demonstration Kit Configuration and User s Guide
HP OpenVMS Software-Based iscsi Initiator Technology Demonstration Kit Configuration and User s Guide November 2007 This manual describes how to configure and use the HP OpenVMS Software-Based iscsi Initiator
More informationRecovery Guide for Cisco Digital Media Suite 5.4 Appliances
Recovery Guide for Cisco Digital Media Suite 5.4 Appliances September 17, 2012 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408
More informationEMC CLARiiON CX3-80. Enterprise Solutions for Microsoft SQL Server 2005
Enterprise Solutions for Microsoft SQL Server 2005 EMC CLARiiON CX3-80 EMC Long Distance Recovery for SQL Server 2005 Enabled by Replication Manager and RecoverPoint CRR Reference Architecture EMC Global
More informationCisco CTL Client setup
Cisco CTL Client setup This chapter provides information about Cisco CTL client setup. About Cisco CTL Client setup, page 2 Remove etoken Run Time Environment 3.00 for CTL Client 5.0 plug-in, page 2 Cisco
More information