Historian SE DATALINK USER S GUIDE

Size: px
Start display at page:

Download "Historian SE DATALINK USER S GUIDE"

Transcription

1 Historian SE DATALINK USER S GUIDE PUBLICATION HSEDL-UM020A-EN-E September 2007

2 Contact Rockwell Automation Customer Support Telephone Online Support Copyright Notice 2007 Rockwell Automation Technologies, Inc. All rights reserved. Printed in USA OSISoft, Inc. All rights reserved. This document and any accompanying Rockwell Software products are copyrighted by Rockwell Automation Technologies, Inc. Any reproduction and/or distribution without prior written consent from Rockwell Automation Technologies, Inc. is strictly prohibited. Please refer to the license agreement for details. Trademark Notices FactoryTalk, Rockwell Automation, Rockwell Software, the Rockwell Software logo are registered trademarks of Rockwell Automation, Inc. The following logos and products are trademarks of Rockwell Automation, Inc.: FactoryTalk Historian Site Edition (SE), RSView, FactoryTalk View, RSView Studio, FactoryTalk View Studio, RSView Machine Edition, RSView ME Station, RSLinx Enterprise, FactoryTalk Services Platform, and FactoryTalk Live Data. The following logos and products are trademarks of OSIsoft, Inc.: PI System, Sequencia, Sigmafine, grecipe, srecipe, and RLINK. Other Trademarks ActiveX, Microsoft, Microsoft Access, SQL Server, Visual Basic, Visual C++, Visual SourceSafe, Windows, Windows ME, Windows NT, Windows 2000, Windows Server 2003, and Windows XP are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Adobe, Acrobat, and Reader are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States and/or other countries. ControlNet is a registered trademark of ControlNet International. DeviceNet is a trademark of the Open DeviceNet Vendor Association, Inc. (ODVA). Ethernet is a registered trademark of Digital Equipment Corporation, Intel, and Xerox Corporation. OLE for Process Control (OPC) is a registered trademark of the OPC Foundation. Oracle, SQL*Net, and SQL*Plus are registered trademarks of Oracle Corporation. All other trademarks are the property of their respective holders and are hereby acknowledged. Restricted Rights Legend Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS Warranty This product is warranted in accordance with the product license. The product s performance may be affected by system configuration, the application being performed, operator control, maintenance, and other related factors. Rockwell Automation is not responsible for these intervening factors. The instructions in this document do not cover all the details or variations in the equipment, procedure, or process described, nor do they provide directions for meeting every possible contingency during installation, operation, or maintenance. This product s implementation may vary among users. This document is current as of the time of release of the product; however, the accompanying software may have changed since the release. Rockwell Automation, Inc. reserves the right to change any information contained in this document or the software at anytime without prior notice. It is your responsibility to obtain the most current information available from Rockwell when installing or using this product. Version:

3 Table of Contents Chapter 1: Chapter 2: Introduction...1 Contents of FactoryTalk Historian DataLink...1 System Requirements...1 For the PI System Manager...3 Add-in to Excel...9 Overview...9 Tutorial...10 PI Menu...17 Dialog Boxes...18 Time in FactoryTalk Historian DataLink...22 FactoryTalk Historian DataLink Functions...27 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes...30 Writing Data from Excel to PI...82 Limits from Excel for FactoryTalk Historian DataLink...84 Appendix A: Troubleshooting...85 DataLink Add-in Doesn't Load Properly...85 Connection Problems Reported in Log Files...86 Appendix B: Expression Syntax...87 Calculation Expressions...87 Filter Expressions...90 Appendix C: Examples of PI Time Strings...93 Start and End Time...93 Time Interval...94 Appendix D: Setup.ini Arguments...95 Silent Installs...95 PI SDK Installation...95 FactoryTalk Historian DataLink Installation...96 FactoryTalk Historian Site Edition DataLink User Guide Page iii

4 Contents Appendix E: Outcodes...97 Example...97 Appendix F: Technical Support and Resources...99 Before You Call or Write for Help...99 Index Page iv

5 Chapter 1: Introduction FactoryTalk Historian DataLink provides a link between the PI 3 or PI 2 Server, and spreadsheet programs running on Microsoft Windows platforms. With FactoryTalk Historian DataLink, a user running Microsoft Excel can exchange information directly with the FactoryTalk Historian System databases. Combined with the functionality of the spreadsheet programs, this feature makes FactoryTalk Historian DataLink a powerful, yet easy-to-use tool for gathering, analyzing, and reporting PI data. Contents of FactoryTalk Historian DataLink FactoryTalk Historian DataLink consists of an add-in for Microsoft Excel FactoryTalk Historian DataLink for Excel is built with the PI SDK product. It allows users who have experience using Microsoft Visual Basic for Applications (VBA) to develop Excel routines that call PI SDK functions. However, users who wish to develop programs outside of Excel must purchase a separate PI SDK or PI API license. Please contact an OSIsoft sales representative for more information. System Requirements FactoryTalk Historian DataLink runs within a suitable spreadsheet application on a Microsoft Windows PC client machine and retrieves information stored on a PI Server through standard network software. Operating System and Network Software The PI Server may run on OpenVMS, Windows, or UNIX. FactoryTalk Historian DataLink communicates with the PI Server via the TCP/IP protocol. FactoryTalk Historian Site Edition DataLink User Guide Page 1

6 Introduction TCP/IP To use TCP/IP, one of the following operating systems is necessary: Microsoft Windows 2000, XP, or Vista Microsoft Windows 2003 Server Users of Microsoft Windows should use the TCP/IP layer built into the operating system. TCP/IP on OpenVMS If the PI Server runs on OpenVMS, one of the following TCP/IP software packages is necessary on the VMS machine: DEC TCP/IP Services for OpenVMS, version 2.0+ Process Software TCPWare, version 3.1+ Cisco MultiNet, version 3.4+ Attachmate Pathway, runtime release 1.1+ Spreadsheet Programs Supported FactoryTalk Historian DataLink supports the following spreadsheet program (32-bit versions only): Microsoft Excel 2000, version 9.0 and later. Configuration of Microsoft Excel If FactoryTalk Historian DataLink will be used with Microsoft Excel, and this is a first time installation (not an upgrade) of FactoryTalk Historian DataLink, you will need to add FactoryTalk Historian DataLink. 1. Start Excel. 2. Bring up Excel's add-in manager via Tools > Add-ins. 3. Browse and select the file PIPC32.XLL. For a local installation, the file PIPC32.xll will be in the...\pipc\excel directory. For a shared installation of FactoryTalk Historian DataLink, look in the...\pipc\excel directory on the network drive. Page 2

7 For the PI System Manager If FactoryTalk Historian DataLink is upgraded and placed in a directory different from the previous versions, then Excel's add-in manager should be used first to remove the old PIPC32.XLL. Then, the new PIPC32.XLL file in the new location should be selected. New Features for Microsoft Excel Users A list of new features in this version of FactoryTalk Historian DataLink is in the...\pipc\readme_datalink.txt file. Bug Fixes A list of known problems that are fixed in this version of FactoryTalk Historian DataLink is in the...\pipc\readme_datalink.txt file. For the PI System Manager PI 2 Server PI Server Service If FactoryTalk Historian DataLink communicates with the PI Server via TCP/IP, the PI System Manager must perform a one-time configuration of the PI Server service. This PI Server service is used by not only FactoryTalk Historian DataLink, but by all OSIsoft PC client applications. Please consult the PIBuild:PIServer.txt file on the VAX/Alpha machine. Security File The PI Server service supports a combination of node authentication and username/password security for PC client applications. The PI Server access file, PISysDat:PIServer.Dat, determines which machines have access to PI data. This file should be created if it does not currently exist. For node authentication security, add entries for particular machines. For example: [USERDATABASE] DEFAULT=PI [CLIENTACCESS] DEFAULT=R PINET1=RW PINET2=RW PC1=RW PC2=NONE The above entries in PISysDat:PIServer.Dat result in the following: FactoryTalk Historian Site Edition DataLink User Guide Page 3

8 Introduction 1. The machines named "PINET1" and "PINET2" have unconditional read and write access to PI data. This level of access must be provided to PINet nodes. 2. The machine named "PC1" also has unconditional read and write access to PI data. This level of security means that anyone with access to "PC1" itself will have unconditional read and write access to PI data via FactoryTalk Historian DataLink. 3. The machine named "PC2" has no access to PI data. This level of security means that no one can use FactoryTalk Historian DataLink on "PC2" to retrieve data into spreadsheets. 4. All other PCs have unconditional read access to PI data. This level of security means that all users on these machines will be able to get data from but not write data to PI with FactoryTalk Historian DataLink. 5. For username/password security, add the letter L after the access type as follows: [USERDATABASE] DEFAULT=PI [CLIENTACCESS] DEFAULT=RL PINET1=RW PINET2=RW PC1=RLWL PC2=NONE This PIServer.Dat is the same as the previous example except in two cases: The machine named "PC1" has conditional read and write access. This level of security means that only user with proper user name and password can read and write on "PC1" via FactoryTalk Historian DataLink. All other PCs have conditional access to PI data. This level of security means that users must provide a valid PI username and password to access PI data and no user can write data back into PI. Be aware that TCP/IP node names are case-sensitive. In addition, the values for the entries in the CLIENTACCESS section (that is, R and W) are also case-sensitive. For node or username/password security to function properly, it is essential that the PI Server be able to determine the name of the PC client running FactoryTalk Historian DataLink. The following sections provide specific information for DECNet and different vendor's TCP/IP. Name Translation - UCX (or TCPIP for VMS 7.2+) Under DEC TCP/IP Services for VMS, the PI 2 Server asks UCX to supply the hostname for a given FactoryTalk Historian DataLink connection. UCX in turn queries the UCX host database on the VAX/Alpha or the Domain Name Server (if configured). To confirm that UCX is determining the PC name properly, type the following from DCL after FactoryTalk Historian DataLink has connected to the PI 2 Server: $ ucx show device /port=545 You should see the remote hostname listed under Remote. It is this hostname whose access level to PI data is being controlled by PISysDat:PIServer.Dat. Page 4

9 For the PI System Manager If instead, you see a number (for example, ) for the remote host, this means that UCX (and hence the PI 2 Server) cannot determine the name of the PC client. Accordingly, the PI 2 Server uses the DEFAULT level access in PISysDat:PIServer.Dat. To add an entry in the UCX host table for a PC: $ ucx set host "mypc" /addr= Consult your UCX documentation for more details. Name Translation - MultiNet Under MultiNet, the PI 2 Server asks MultiNet to supply the hostname for a given FactoryTalk Historian DataLink connection. MultiNet in turn queries the MultiNet host database on the VAX/Alpha or the Domain Name Server (if configured). To confirm that MultiNet is determining the PC name properly, type the following from DCL after FactoryTalk Historian DataLink has connected to the PI 2 Server: $ multinet show You should then see the name of the local host as well as the name of the foreign (PC) host. It is this latter hostname whose access level to PI data is being controlled by PISysDat:PIServer.Dat. If instead, you see a number (for example, ) for the foreign host, this means that MultiNet (and hence the PI 2 Server) cannot determine the name of the PC client. Accordingly, the PI 2 Server is using the DEFAULT level access in PISysDat:PIServer.Dat. To add an entry in the MultiNet host table on the VAX/Alpha for a PC, you need to edit the MultiNet:Hosts.Local file. After editing, you should run the following commands: $ multinet host_table compile Consult your MultiNet documentation for more details. Name Translation - PathWay Under PathWay, the PI 2 Server asks PathWay to supply the hostname for a given FactoryTalk Historian DataLink connection. PathWay in turn queries the host database on the VAX/Alpha or the Domain Name Server (if configured). To confirm that PathWay is determining the PC name properly, type the following from DCL after FactoryTalk Historian DataLink has connected to the PI 2 Server: $ netstat FactoryTalk Historian Site Edition DataLink User Guide Page 5

10 Introduction You should then see the name of the local host as well as the name of the foreign (PC) host. It is this latter host name whose access level to PI data is being controlled by PISysDat:PIServer.Dat. If instead, you see a number (for example, ) for the foreign host, this means that PathWay (and hence the PI 2 Server) cannot determine the name of the PC client. Accordingly, the PI 2 Server is using the DEFAULT level access in PISysDat:PIServer.Dat. To add an entry in the PathWay host table on the VAX for a PC, you need to edit the twg$etc:hosts.file. Consult your PathWay documentation for more details. Name Translation - TCPWare Under TCPWare, the PI 2 Server asks TCPWare to supply the hostname for a given FactoryTalk Historian DataLink connection. TCPWare in turn queries the host database on the VAX/AlphaAXP or the Domain Name Server (if configured). To confirm that TCPWare is determining the PC name properly, type the following from DCL after FactoryTalk Historian DataLink has connected to the PI 2 Server: $ netcu show connections /host_names You should then see the name of the local host as well as the name of the remote (PC) host. It is this latter host name whose access level to PI data is being controlled by PISysDat:PIServer.Dat. If instead, you see a number (for example, ) for the remote host, this means that TCPWare (and hence the PI 2 Server) cannot determine the name of the PC client. Accordingly, the PI 2 Server is using the DEFAULT level access in PISysDat:PIServer.Dat. To add an entry in the TCPWare host table on the VAX/Alpha for a PC, you need to edit the TCPWare:Hosts file. You may need to restart TCPWare in order for the change to take effect. Consult your TCPWare documentation for more details. PI 3 Server Firewall Database The firewall database on the machine on which PI 3 Server is running must be configured to allow access by PCs on which FactoryTalk Historian DataLink is running. For example, pi_gen,pifirewall hostmask,value hostmask=* *.*.*.*, ALLOW The above indicates that all PCs may connect to PI 3 Server. *.*.*.*, DISALLOW *, ALLOW Page 6

11 For the PI System Manager The above indicates that only PCs whose TCP/IP address start with are allowed to connect. For more information, consult the PI Server User Manuals included on the FactoryTalk Historian SE installation CD under Redist > Docs. Trust Database The trust database on the machine on which PI 3 Server is running may be configured to allow access without explicit login by PCs on which FactoryTalk Historian DataLink is running. For example, pitrust trust,ipaddr,iphost,piuser trust=* MyPCTrust, ,mypc,piadmin The above indicates that any app connecting to PI 3 Server from "mypc" gets piadmin privileges by default. For more information, consult the PI Server User Manuals that are included on the FactoryTalk Historian SE installation CD under Redist > Docs. Point Access/Data Access Attributes When FactoryTalk Historian DataLink connects to PI 3 Server, it asks the user for a username and password. This username is used in conjunction with the PtOwner, PtAccess, DataOwner, and DataAccess fields. For example, if the tag SINUSOID is configured such that PtAccess is O:RW, G:NONE, W:NONE, and PtOwner is USER1, FactoryTalk Historian DataLink users must log in as USER1 in order to see this tag. Otherwise, the tag will not be found. Also, if SINUSOID DataAccess is O:R, G:NONE, W:NONE, and DataOwner is USER1, FactoryTalk Historian DataLink users must log in as USER1 in order to see data for this tag. Otherwise, a read access error message is returned. However, even logging on as USER1 in this case will not allow FactoryTalk Historian DataLink to write data to SINUSOID because the DataAccess attribute is O:R (read only). The PI System Manager would need to change DataAccess to O:RW (read and write). Only after this change is made can FactoryTalk Historian DataLink users who log in as USER1 be able to read and write data for SINUSOID. For more information, consult the PI Server User Manuals that are included on the FactoryTalk Historian SE installation CD under Redist > Docs. FactoryTalk Historian Site Edition DataLink User Guide Page 7

12 Introduction Note: The user PIAdmin is a "super"-privileged user. A user of FactoryTalk Historian DataLink who logs in as PIAdmin has read and write access to all tags. For this reason, FactoryTalk Historian DataLink users normally should NOT log in as PIAdmin. Page 8

13 Chapter 2: Add-in to Excel Overview The FactoryTalk Historian DataLink add-in for Excel provides users of Microsoft Excel with the ability to retrieve data associated with tags on a PI Server, directly into a spreadsheet. Moreover, users have the ability to write spreadsheet values back into PI. FactoryTalk Historian DataLink provides the following functions to retrieve data from PI: Current value Value at a specific time Tag attributes Evenly spaced (sampled) data Sampled data while a given expression is true Compressed (archived) data Compressed data while a given expression is true Sampled data for a user specified array of timestamps Data from calculations on PI tag expressions Amount of time while a PI tag expression was true Totals, minima, maxima, standard deviations, ranges, averages, counts and means for PI tags and PI expressions Tagname from a specified Point ID Tagnames from specified attribute masks Alias value from module database Property value from module database FactoryTalk Historian Site Edition DataLink User Guide Page 9

14 Add-in to Excel Tutorial The goal of this tutorial is to get you started with using FactoryTalk Historian DataLink in Excel as quickly as possible. FactoryTalk Historian DataLink's features are not discussed in detail in this tutorial. Rather, it will serve to familiarize the user with the overall operation of this add-in. Verify Communications with PI Server In this first example, we will confirm that FactoryTalk Historian DataLink has been installed properly and that it can connect to the PI Server. Start Excel and make sure that the PI menu choice is in Excel's menu bar. If PI does not appear, you need to use Excel's add-in manager. See Configuration of Microsoft Excel. From the PI Connection Manager dialog box, check the checkboxes in the left-hand panel. If the Status indicates that the PI Server is not connected, click the checkbox to connect. Page 10

15 Tutorial Tag Attributes and Current Value In this next example, we obtain the tag descriptor, current value, and engineering units for some tags. 1. Open Excel. 2. From the PI menu, select Settings... and make sure that the In a column radio button in the "Copy items to sheet" section is chosen. 3. Next, dismiss the dialog box and move the cursor to cell A2 in the spreadsheet. 4. Select Tag Search... from the PI menu and enter "BA*" into the Tag Mask field. 5. Click Search to find tags that being with "BA". The Search Results list should contain at least five tags: BA:ACTIVE.1, BA:CONC.1, BA:LEVEL.1, BA:PHASE.1, and BA:TEMP Select these five tags from the Search Results list by clicking on the first tag (BA:ACTIVE.1) and then simultaneously holding the CTRL key and clicking on each of FactoryTalk Historian Site Edition DataLink User Guide Page 11

16 Add-in to Excel the four other tags. Then, click OK to copy the five tags along a single column, from A2 to A6. 7. Move the cursor to cell B2. From the PI menu, select Tag Attributes... Click the edit box under Tagname(s). 8. Position the mouse over cell A2 in the spreadsheet. Click and drag to select the reference A2:A6. 9. Type or select "descriptor" from drop-down box below Attribute. 10. Click OK in the dialog box. FactoryTalk Historian DataLink then retrieves Tag descriptors into cells B2 to B Move the cursor to cell C2. From the PI menu, select Current Value... Click the edit box under Tagname. Position the mouse over cell A2 in the spreadsheet. Click and drag to select the reference A2:A6. In the dialog box, click the time at left radio button. Page 12

17 Tutorial 12. Click OK in the dialog box. FactoryTalk Historian DataLink then retrieves current values and the timestamps of these current values into columns D and C, respectively. 13. Move the cursor to cell E2 in the spreadsheet. From the PI menu, select Tag Attributes... again. Click the edit box under Tagname(s). 14. Position the mouse over cell A2 in the spreadsheet. Click and drag to select the reference A2:A6. Select engunits from the Attribute list box. 15. Click OK in the dialog box. FactoryTalk Historian DataLink then retrieves engineering units into cells E2 to E6. FactoryTalk Historian Site Edition DataLink User Guide Page 13

18 Add-in to Excel Actual Values from the PI Server In this example, we gather sampled data for a single tag. 1. Move the cursor to cell C10. From the PI menu, select Sampled Data... Click the Tag Search button. The Tag Search dialog box then appears. 2. Enter "CD*" into the Tag Mask field. Click Search to search for tags that begin with CD. The tag "cdt158" should be returned. Select this tag and click OK. 3. The tag cdt158 then appears in the Tagname field in the Sampled Data dialog box. Enter t (for midnight today) in the Start Time field, +8h (eight hour offset from start time) in the End Time field, and 1h (one hour interval) in the Time Interval field. Click the show timestamps check box. 4. Click OK. FactoryTalk Historian DataLink then retrieves interpolated data from midnight to 8:00am at 1-hour intervals. Page 14

19 Tutorial Changing Arguments from the Dialog Box In this example, we make a change to the end time used in the previous example. 1. Right click on any part of the array created in the previous example 2. Select Sampled Data Change the end time from "+8h" to "+9h" and click OK. FactoryTalk Historian DataLink then retrieves interpolated data from midnight to 9:00am at 1-hour intervals. Note that the array size has increased by one row. FactoryTalk Historian Site Edition DataLink User Guide Page 15

20 Add-in to Excel Using Old Arrays as Templates In this example, we show how to use an old array as a template for a different tag. 1. Right click on any part of the array created in the previous example 2. Select Sampled Data Change the tag edit field from "CDT158" to "SINUSOID" 4. Change the Output Cell from $C$10 to $A$10 and click OK. Notice that the sampled data for tag "SINUSOID" is in A10. FactoryTalk Historian DataLink Summary As the above examples indicate, the fastest way to use FactoryTalk Historian DataLink to transfer data between PI and Excel is to select an option from the PI menu item. A dialog box then appears. Enter the appropriate parameters and FactoryTalk Historian DataLink retrieves the requested PI values. The next sections describe the features of FactoryTalk Historian DataLink in greater detail. Page 16

21 PI Menu PI Menu When FactoryTalk Historian DataLink is added to Excel, it adds the PI menu item to Excel's menu bar. Pop-up menu selections are available from this menu item. These are: Current Value retrieves the current value for a tag Archive Value retrieves a single value from the archive (may be interpolated) Tag Attributes retrieves a tag attribute FactoryTalk Historian Site Edition DataLink User Guide Page 17

22 Add-in to Excel Compressed Data (Start Time/Number) retrieves compressed data based on a start time and a specified number of values with an optional filter condition Compressed data (Start Time/End Time) retrieves compressed data based on a start time and an end time with an optional filter condition Sampled Data retrieves evenly spaced (sampled) data from the archive with an optional filter condition Timed Data retrieves sampled data synchronized with an array of timestamps Calculated Data retrieves totals, minima, maxima, ranges, standard deviations, averages and means for multiple time periods Advanced Calculated Data is similar to calculated data but with more advanced options (i.e. event weighted) Time Filtered retrieves the amount of time over which a tag expression is true Point ID to Tag retrieves a tagname from specified point ID Attribute Mask to Tag retrieves tagnames from specified attribute masks Alias retrieves an alias tagname from the module database Property retrieves a property value from the module database Insert Trend creates a trend that can directly get data from PI or off the worksheet Tag Search searches for PI tags Module Database displays module database contents such as aliases and properties Connections manages PI Server connections Settings displays FactoryTalk Historian DataLink settings and preferences About displays version information on FactoryTalk Historian DataLink Help displays help on FactoryTalk Historian DataLink Dialog Boxes Edit Fields The edit fields can contain either the necessary text information or references to cells, which contain the necessary text information. FactoryTalk Historian DataLink determines the type of information entered in the edit field by context. Page 18

23 Dialog Boxes As opposed to typing in the cell reference, you may also use the mouse to click the edit field, and then click the cell (or click the cell and drag to adjacent cells) on the spreadsheet. In this procedure, Excel automatically enters the cell reference(s) into the edit field for you. For example, in the dialog box below, the edit fields for Tagname and Output ask for a cell on the spreadsheet that contains the tagname and a cell on the spreadsheet where you wish to place the output of the current value, respectively. PI Server and Output Fields The PI Server field allows the selection of a PI server from the known servers list. In the drop-down list, the servers above the dotted line are the servers currently connected and the ones below are currently disconnected. The PI Server field in all of the dialog boxes is labeled as opt. or optional. If the PI Server field is blank, FactoryTalk Historian DataLink will use the default PI Server. You can change the default PI Server in the Connections... dialog box available from the PI menu. The Output field allows you to specify the upper left-hand corner of the range where FactoryTalk Historian DataLink will place the resulting data. Data Displayed as Columns or Rows For dialog boxes that expect to return an array of PI values (for example, Sampled data), there is a set of radio buttons with options column(s) or row(s). Choose column(s) to display the data in either one column, two columns if timestamps OR percent good are to be FactoryTalk Historian Site Edition DataLink User Guide Page 19

24 Add-in to Excel displayed, or three columns if timestamps AND percent good are to be displayed. Choose row(s) to display the data in either one, two, or three rows. Page 20

25 Dialog Boxes For dialog boxes that expect to return a single PI value (e.g., Current value), there is a set of radio buttons with options no timestamp, time at left or time on top. Choose time at left to display data in two columns. Choose time on top to display data in two rows. For dialog boxes that support an array of tags, the orientation of the tag array will override your row/column option selection in determining the orientation of the output data. List Boxes List boxes appear for the Mode field in Archive Value..., for the Type fields in Compressed Data (Number) and (Times)..., for the Mode fields in Calculated and Advanced Calculated data..., and for the Time Unit fields in Time Filtered... dialog boxes. The default retrieval mode from Archive Value... is interpolated, the default boundary type from both Compressed Data (Number) and (Times)... is inside, the default calculation mode from both Calculated and Advanced Calculated Data... is total, the default expression sampling mode from Advanced Calculated Data... is pt. compressed, and the default time unit for Time Filtered... is seconds. Combo Boxes Combo boxes appear for the Attribute field in Tag Attributes... The Point Class field is automatically populated with all the available point classes for the listed PI server. Whenever a new PI server is selected in the PI Server field, the Point Class field is repopulated. Whenever a point class is selected in the Point Class field, the Attribute field is repopulated. When a valid tag is entered, its point class will be retrieved and entered into the Point Class field automatically. Tag Search in Dialog Boxes The <...> button next to the tagname field in the dialog boxes allows you to search the PI database for tags. Clicking the button will bring up the Tag Search dialog box. If you press OK in the Tag Search dialog box, the first tagname selected will be copied to the tagname edit field. The PI Server name is also copied to the PI Server edit field if you checked the "Copy PI Server name" box in the FactoryTalk Historian DataLink settings. FactoryTalk Historian Site Edition DataLink User Guide Page 21

26 Add-in to Excel Time in FactoryTalk Historian DataLink Returned Values The timestamps returned by the FactoryTalk Historian DataLink dialog boxes are in Excel format; i.e., the number represents the number of days since For example, 10-Dec-99 7:12pm is entered into a cell as the number However FactoryTalk Historian DataLink formats these timestamps into a PI time string; specifically, dd-mmm-yy hh:mm:ss. For example, 7:12 PM on December 10th, 1999 is displayed as 10-Dec-99 19:12:00. You can change this format to another by selecting the cells and choosing Format, Cells, Number. See your Excel documentation for more information on formatting numbers as time. User-Specified Time and Number Formatting If you do not like the general and dd-mmm-yy hh:mm:ss formatting codes for number and time, respectively, you can specify another default number and time formatting code in FactoryTalk Historian DataLink. This is done via the PI > Settings... dialog box. Page 22

27 Time in FactoryTalk Historian DataLink The number format "0.0" formats numbers to one decimal place and the time format "hh:mm:ss" timestamps to be hour:minute:seconds. The entries for the number format and time format fields may be any valid Excel format code from Format, Cells, Number, Custom. For example in German, the equivalent of "General" and "dd-mmm-yyyy hh:mm" are "Standard" and "TT-MM-JJJJ hh:mm" respectively. FactoryTalk Historian Site Edition DataLink User Guide Page 23

28 Add-in to Excel Entering Timestamps into FactoryTalk Historian DataLink Many of the dialog boxes ask for a start time and an end time. In the edit fields, type the desired PI time string, for example, 10-Dec-99 19:12. Note that for PI time in relative time format (for example, '-1d'), the reference time is different for the start time and the end time. The current wall clock is the reference time for the translation of the relative time in the start time field. However, the start time is used as the reference time for the translation of the relative time in the end time field. If you want to use cell references, you may refer either to cells that contain a PI time in string format (e.g., '10-Dec-99 19:12) or to cells that contain an Excel time (for example, , formatted in whatever style you wish). Remember that Excel stores time as the number of days since 1900, but displays it according to Format, Cells, Number. For the time interval edit field, you may specify a number followed by an h or an m or an s (for hours, minutes, or seconds, respectively). For example, to indicate a time interval of thirty two minutes, type 32m into the edit field. If you want to use cell references, you may refer only to cells that contain a valid PI time interval string. That is, you cannot refer to a cell containing an Excel time (i.e., a number). For example, to specify an interval of 32 minutes, the time interval edit field of a dialog box must refer to a cell that contains the string 32m. Page 24

29 Time in FactoryTalk Historian DataLink See Start and End Time (page 93) and Time Interval (page 94) for examples of valid PI time strings. Show Time Check Box A show time check box appears in some of the dialog boxes, whose PI function normally returns an array of PI values. Selecting this check box returns the timestamps as well as the values. These timestamps appear at the leftmost column if the column(s) radio button is selected; and along the topmost row if the row(s) is selected. If this box is unchecked, FactoryTalk Historian DataLink does not display the timestamps. If you reference an array of tags in either the Sampled Data or Calculated Data dialog box, FactoryTalk Historian DataLink returns one common set of timestamps for the entire group of tags. FactoryTalk Historian Site Edition DataLink User Guide Page 25

30 Add-in to Excel Positioning Timestamp Data Returned by FactoryTalk Historian DataLink Some dialog boxes that return a single value (for example, Current Value) provide radio buttons that control where timestamps are displayed. Select no timestamp to suppress the timestamp. Select time at left to return a timestamp into a cell to the left of the retrieved values. Select time on top to display the timestamp in a cell above the retrieved values. Note: When an array reference is specified in the Tagname field, the time at left and time on top radio buttons produce the same result. In this case, FactoryTalk Historian DataLink returns the timestamp and value depending on whether the reference of tag names is horizontal or vertical. For tag names in a single column, timestamps will appear to the left of the values. For tag names in a single row, timestamps will appear on top of the values. Timestamp Data for a Time Interval or Range Some dialog boxes that return a single value for each interval of time (for example, Calculated Data) provide check boxes that control which timestamps are displayed. When a time interval is specified: Select Start Time to display the start time of the interval. Select End Time to display the end time of the interval. For minimum, maximum, and range functions: Select Min/Max Time to display timestamps for the interval's minimum and maximum values. The timestamps are displayed according to the orientation (rowwise or columnwise) specified. For instance, if the orientation is columnwise and if all check boxes are selected, the order of the columns from left to right would be: start time, end time, the timestamp of the minimum value, the timestamp of the maximum value. If the check box for End Time is cleared, for the same example the order from left to right would be: start time, the timestamp of the minimum value, the timestamp of the maximum value. Page 26

31 FactoryTalk Historian DataLink Functions FactoryTalk Historian DataLink Functions Functions vs. Values When a FactoryTalk Historian DataLink dialog box brings data from the PI Server to Excel, it does not put the actual value into a cell. Rather, FactoryTalk Historian DataLink pastes a custom PI function into the cell. For example, when you call up the Current Value dialog box and enter SINUSOID into the Tagname field, FactoryTalk Historian DataLink pastes the following function into the cell: =PICurrVal("sinusoid",0,) Excel then evaluates this function, and displays the resulting number. Thus, the FactoryTalk Historian DataLink dialog boxes are a front end to construct the corresponding FactoryTalk Historian DataLink functions, and to format the output. These FactoryTalk Historian DataLink functions can also be entered manually into the cells in a worksheet. The arguments to the function are described further in Details for FactoryTalk Historian DataLink Functions and Dialog Boxes (page 30). Since most of the FactoryTalk Historian DataLink functions return more than one data element, the functions should be entered into Excel as array functions. Please see the Entering PI Functions Directly into Excel section below for a more detailed explanation of how array functions are used. These FactoryTalk Historian DataLink functions can only be used in cells of a worksheet. They cannot be called within a procedure in Excel Visual Basic. Visual Basic does not recognize FactoryTalk Historian DataLink functions. The only way to invoke the FactoryTalk Historian DataLink functions in VBA is to formulate the function as a text string and then set the formula Array property of a range of cells to this text string. This is the same as manually entering the PI functions into that range of cells. The VBA code can then check the cell values for the PI function results. For an example of entering PI functions into the spreadsheet using VBA, see the putval_code module in the piexam32.xls distributed with FactoryTalk Historian DataLink. The FactoryTalk Historian DataLink output function PIPutVal() is an Excel Macro function and cannot be used directly in the cells of a worksheet. PIPutVal() can only be used in an Excel 4.0 macro sheet or run as a macro in VBA. In VBA, use the application.run method to invoke macro functions. Please refer to the putval_code module in the piexam32.xls for an example of invoking the macro function in VBA. Error Reporting FactoryTalk Historian DataLink is written in C++ and Visual Basic and utilizes both the FactoryTalk Historian System's SDK and Microsoft Excel's API. When an error occurs at the FactoryTalk Historian Site Edition DataLink User Guide Page 27

32 Add-in to Excel PI SDK level, FactoryTalk Historian DataLink displays the PI SDK error in the cell. For example, if you try to find the current value for a tag which does not exist, the message "PIPoint not found" appears in the output cell. Refreshing PI Data in a Spreadsheet There are two ways to refresh the data on a spreadsheet. One way is to right click on any part of the array and select the Recalculate (Resize) function. This method works best if you have a variable size array where the number of values returned could be different depending on what range of values retrieved. If there are fewer values, there is no problem. However, if more values are retrieved, those values will not show unless the Recalculate function is selected. The second way is to make a change to the arguments passed to the FactoryTalk Historian DataLink functions. Because FactoryTalk Historian DataLink retrieves data from the PI Server via functions, values on the spreadsheet update only when a function argument changes. Pressing F9 in Excel does not force FactoryTalk Historian DataLink functions to get new data from the PI server. The only exception is the Current value function, which updates whenever Excel recalculates. This was intentionally done because most of the other DataLink functions do not represent chronically changing data. However, to bypass this, Ctrl+Alt+Shift+F9 forces all DataLink functions to recalculate. The best way to create a spreadsheet that updates with minimal user interaction is to use some Excel dynamic time functions like now() or today() to build a time stamp, e.g. use (today()+1/3) for 8am today. Then refer to this cell in the start time or end time argument of the DataLink query. Whenever Excel recalculates (due to the user pressing F9 or changing any cells in the spreadsheet), the dynamic time functions will be updated by Excel, causing the FactoryTalk Historian DataLink function to run. Note that the value of the time stamp does not have to change in order for Excel to trigger the FactoryTalk Historian DataLink function. As long as an Excel dynamic time function is used to construct the time stamp and this time stamp is used in the DataLink argument, Excel will trigger the DataLink function when the spreadsheet recalculates. Changing Arguments using Dialog Boxes If an argument needs to be changed, right click on any part of the array and select the FactoryTalk Historian DataLink function. A dialog box will appear with all the edit fields filled in with the arguments that were previously specified for that array. Any of the edit fields can be changed and the new array will reflect those changes. If the output edit field is changed, there are two different behaviors depending on what new cell is referenced. If the newly referenced cell is part of the original array, then the entire array gets moved with the upper-leftmost cell of the array at the newly referenced cell. If the newly referenced cell is not part of the original array, then the array is pasted with the upper-leftmost cell of the array at the newly referenced cell. Page 28

33 FactoryTalk Historian DataLink Functions Selecting an Entire DataLink Function If a large FactoryTalk Historian DataLink function array needs to be copied, moved or deleted, the easiest way is to right click on any part of the array and select Select DataLink Formula. Then perform the desired operation. The entire Excel function array must be moved or deleted, or an error "You cannot change part of an array" appears. Entering PI Functions Directly into Excel Array Values All of FactoryTalk Historian DataLink functions except PIPutVal() return array values. This being the case, you must first select the appropriate array output range. Next, enter the PI function and its arguments into Excel's formula bar. Finally, place the PI function into the cells with the CTRL+SHIFT+ENTER combination of keystrokes. Refer to the online help for Microsoft Excel for more information on array functions. Also, note that Excel function wizard will only insert function into one cell on the spreadsheet. Therefore, it may not be appropriate to use the function wizard to enter PI functions into Excel. Outcode The outcode argument is an integer that controls whether or not the timestamps are returned and whether the output cells are row or column oriented. For example, an outcode of 0 in PICurrVal() results in the snapshot value in the single cell. An outcode of 1 places the snapshot time in column one and the snapshot value in column two of a 1 x 2 array. An outcode of 2 places the snapshot time in row one and the snapshot value in row two of a 2 x 1 array. Refer to the detail description for each individual PI function for the meaning of its outcode. In general, if you specify an array output range that is greater than the number of values returned from the function, the extra cells are displayed as empty cells even though they have an embedded formula. String Arguments For string arguments to functions, you need to surround the arguments with double quotes. For example, select a 1 x 2 output array and enter: =PICurrVal("sinusoid", 1, "casaba") to retrieve the snapshot time and value for the tag sinusoid from the PI Server "casaba." FactoryTalk Historian Site Edition DataLink User Guide Page 29

34 Add-in to Excel Using Cell Reference in Arguments You can use cell references for all the arguments in all of FactoryTalk Historian DataLink functions. For example, the following function: =PICurrVal(A1, A2, A3) gives the same result as the example above if the three arguments are stored in cell A1, A2, and A3 respectively. PIServer Argument The PIServer argument is optional. The default PIServer can be changed in the Connections dialog box. If you want to use the default server, you can omit the PIServer argument. For example, to retrieve the current value for the tag sinusoid from the default PI Server, enter: =PICurrVal("sinusoid",0,) into a 1x1 output range. Details for FactoryTalk Historian DataLink Functions and Dialog Boxes The following sections describe each of the FactoryTalk Historian DataLink functions in detail. Each section describes the dialog box first and then discusses each of the arguments for the corresponding custom PI function or functions. Current Value Dialog Box This dialog box gets the current Snapshot value of a PI tag. Required Field Tagname. The reference to Tagname may be an array. Special Notes This function updates whenever Excel calculates or recalculates any cell in the spreadsheet. To force an immediate recalculation, press the F9 key. PICurrVal() PICurrVal(tagname, outcode, PIServer) Page 30

35 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes Arguments Argument Explanation Tagname (string) The tag for which you want the snapshot (current) value. outcode (integer) An output code; either 0, 1, or 2. PIServer (string) The PI Server. Returns Outcode Column 1 Column 2 0 Current value 1 Timestamps Current value An output code of 2 transposes the output array that results from an output code of 1. Example The following retrieves the current value and the corresponding timestamp for the tag let439 from the PI Server "holden:" =PICurrVal("let439",1,"holden") Archive Value Dialog Box This dialog box gets a value at a specified time. There are five modes to select from: Previous - Retrieves the value in the archive at or before the specified timestamp Previous only - Retrieves the value in the archive only before the specified timestamp Interpolated - Interpolates the value at the specified timestamp except for resolution code 4 tags on PI 2 Server and tags with step attribute set on PI 3 Server. For this special case, the previous value is simply carried forward. Auto - Same as interpolated except for resolution code 4 tags on PI 2 Server and tags with step attribute set on PI 3 Server. For this special case, the value at or before the specified timestamp is returned Next - Retrieves the value in the archive at or after the specified timestamp Next Only - Retrieves the value in the archive only after the specified timestamp Exact Time - Retrieves the value in the archive for a specified time if an entry exists at that time. If no value exists, the message "No events found" is returned FactoryTalk Historian Site Edition DataLink User Guide Page 31

36 Add-in to Excel Required Fields Tagname or Expression Timestamp Related Topics PIArcVal() (page 32) PIExpVal() (page 33) PIArcVal() PIArcVal(tagname, timestamp, outcode, PIServer, mode) Arguments Argument Explanation tagname (string) The tag for which you want the archive value. time stamp (string) The PI timestamp. outcode (integer) An output code; either 0, 1, or 2. PIServer (string) The PI Server. mode (string) The retrieval mode. Returns Outcode Column 1 Column 2 0 Archive value 1 Timestamp Archive value An output code of 2 transposes the output array that results from an output code of 1. Example The following retrieves the interpolated value for the tag cdep158 at 7:20pm on December 11, 1992 from the PI Server "casaba:" =PIArcVal("cdep158","11-dec-92 19:20",0, "casaba","interpolated") Page 32

37 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes PIExpVal() PIExpVal(expression, timestamp, PIServer) Arguments Argument expression (string) time stamp (string) PIServer (string) Explanation The expression for which you want the archive value. The PI timestamp. The PI Server. Returns Outcode Column 1 Column 2 0 Archive value 1 Timestamp Archive value An output code of 2 transposes the output array that results from an output code of 1. Example The following calculates the square root of the value of the tag sinusoid from the PI Server named THEVAX at midnight yesterday: =PIExpVal("sqr('sinusoid')","y",0,"thevax") Tag Attributes Dialog Box This dialog box retrieves a point attribute for a given tag. Required Fields Tagname Tag attribute For PI3, the list of tag attributes depends on the point class selected. For a complete list of tag attributes, refer to the attributes listed in the combo box or to the description of attributes for each point class in the PI Server User Manuals, available from the FactoryTalk Historian SE installation CD under Redist > Docs. FactoryTalk Historian Site Edition DataLink User Guide Page 33

38 Add-in to Excel For PI 2, choose a tag attribute from the combo box. The default attribute is descriptor. Tag attributes are: Attribute Descriptor Exdesc typicalvalue Units Zero Span digstartcode Explanation 26-character tag descriptor 80-character extended tag descriptor Typical value Engineering unit string Zero Span Code for the first digital state string for the tag dignumber Number of digital states minus 1 pointtype pointsource Point type character Point source character location1 Location parameter 1 location2 Location parameter 2 location3 Location parameter 3 location4 Location parameter 4 location5 Location parameter 5 filtercode squareroot scan excdev excmin excmax archiving compressing Res compdev compmin compmax totalcode convers displaydigits instrumenttag sourcept taglong Filter code Square root flag Scan flag Exception deviation in percent of span Exception minimum time in seconds Exception maximum time in seconds Archiving flag Compression flag Resolution code Compression deviation in percent of span Compression minimum time in seconds Compression maximum time in seconds Totalization code Conversion factor for postprocessed points Controls the format of numeric values on terminal-based PI screens Tagname for value in another system; used by some interfaces Tagname for output to other systems; used by some interfaces Long tagname (up to 80 characters) Page 34

39 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes Attribute tagshort creator createdate changer changedate pointnumber pointid Explanation 12 character tagname Creator of the tag Creation date of the tag User who modified the tag's attributes Change date of the tag ID number reused upon deletion of a point Unique internal ID number not reused upon deletion of a point PITagAtt() PITagAtt(tagname, attribute, PIServer) Arguments Argument Explanation tagname (string) The tag for which you want an attribute. attribute (string) The tag attribute, see the list under Tag Attributes Dialog Box (page 33). PIServer (string) The PI Server. Returns Tag attribute Example The following retrieves from the default PI Server the engineering units for the tag located in cell D1: =PITagAtt(d1,"units",) Compressed Data (Start Time/Number) Dialog Box This dialog box returns compressed values from the PI Server based on a start time and a specified number of data points. If a filter expression is not specified, the PINCompDat() function is called. Otherwise, the PINCompFilDat() function is called. Required Fields Tagname Start Time FactoryTalk Historian Site Edition DataLink User Guide Page 35

40 Add-in to Excel Number of data points Filter Expression If a filter expression is specified, the specified number of compressed values are retrieved from the PI Server while a given filter expression is true. If the mark as filtered option is selected, a "Filtered" status is returned for each group of values that does not satisfy the filter expression. See Filter Expressions (page 90) for more information on the filter expression syntax. Boundary Type There are 4 boundary types: Inside (default) - Returns specified number of data points from starttime including value at starttime if a value exists Outside - Returns specified number of data points from starttime including a data point at or prior to starttime Interpolated - Returns specified number of data points from starttime including a data point interpolated at starttime Auto - Same as interpolated except if resolution code 4 tags on PI 2 Server or step attribute is set on PI 3 Server, behavior follows that of "inside" Check Boxes Select backwards in time if you want to gather data from the archive going backwards from the time that was entered in Start time. Select show bits if you want to show the extended status bits associated with the returned events. Select show annotations if you want to show the annotations associated with the returned events. Special Notes This dialog box returns empty strings when there is a smaller number of values than the number which you specified. For example, if you wish to retrieve 400 values starting from midnight today and there are only 356 values (including filtered events), the final 44 cells have blank strings in them. Page 36

41 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes If you enter the filter expression into a cell on the worksheet and refer to it in the dialog box, be sure to begin the expression with a single quote so that Excel will interpret the expression as a string. Since tag names in filter expression are enclosed with single quotes, if the filter expression begins with a tagname, you must begin the expression with two single quotes when the filter expression is stored in a cell on the worksheet. Related Topics Filter Expressions (page 90) PINCompDat() (page 37) PINCompFilDat() (page 38) PINCompDat() PINCompDat(tagname, stime, numvals, outcode, PIServer, mode) Arguments Argument tagname (string) stime (string) numvals (integer) outcode (integer) PIServer (string) mode (string) Explanation The tag for which you want compressed data. The start time in PI time format. The number of compressed data points. Use a negative number to gather data from the archive that goes backwards from the stime. An output code. See Outcodes for more information on outcodes. The PI Server. The boundary type. Returns Outcodes Example The following retrieves 10 compressed data points and corresponding time stamps for the tag cdf144 starting from 1:00 a.m. this morning from the default PI Server with inside as boundary type: =PINCompDat("cdf144","1:00",10,1,,"inside") FactoryTalk Historian Site Edition DataLink User Guide Page 37

42 Add-in to Excel PINCompFilDat() PINCompFilDat(tagname, stime, numvals, filtexp, filtcode, outcode, PIServer, mode) Arguments Argument tagname (string) stime (string) numvals (integer) filtexp (string) filtcode (integer) outcode (integer) PIServer (string) mode (string) Explanation The tag for which you want compressed data. The start time in PI time format. The number of compressed data points. Use a negative number to gather data from the archive that goes backwards from the stime. The filter expression. See Filter Expressions (page 90) for more information on the filter expression syntax. A filter code; use 1 to return Filtered status, 0 to skip. An output code. See Outcodes for more information on outcodes. The PI Server. The boundary type. Returns Refer to Outcodes. Example The following retrieves 10 compressed data points and the corresponding times, starting at 2:00 a.m., for the tag cdf144 while the tag cdep158 is greater than 38: =PINCompFilDat("cdf144","2:00",10,"'cdep158'>38",1,1,,) The status Filtered is displayed for times when the filter condition is false. Data are retrieved from the default PI Server with inside as boundary type. Compressed Data (Start Time/End Time) Dialog Box This dialog box returns compressed values from the PI Server based on a start time and an end time. The number of data points retrieved for the given time period is returned in the first cell. If a filter expression is not specified, the PICompDat() function is called. Otherwise, the PICompFilDat() function is called. Page 38

43 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes Required Fields Tagname Start Time End Time Filter Expression If a filter expression is specified, the specified range of compressed values are retrieved from the PI Server while a given filter expression is true. If the mark as filtered option is selected, a "Filtered" status is returned for each group of values that does not satisfy the filter expression. See Filter Expressions (page 90) for more information on the filter expression syntax. Boundary Type There are 4 boundary types: Inside (default) - Returns data points at and between starttime and endtime Outside - Returns data points between starttime and endtime including a data point at or prior to starttime and a data point at or after endtime Interpolated - Returns data points between starttime and endtime including a data point interpolated at starttime and a data point interpolated at endtime Auto - Same as interpolated except if resolution code 4 tags on PI 2 Server or step attribute is set on PI 3 Server, behavior follows that of "inside" Check Boxes Select hide count if you do not want to display the amount of data events retrieved from the archive. Select show bits if you want to show the extended status bits associated with the returned events. Select show annotations if you want to show the annotations associated with the returned events. FactoryTalk Historian Site Edition DataLink User Guide Page 39

44 Add-in to Excel Special Notes This dialog box returns blank strings in the unused output cells when there is a smaller number of values in the archive than the output array originally specified. This situation may occur if you use relative time references. For example, if you retrieve values starting from y to y+5h, the number of values in the PI Server may be different when you call up the spreadsheet on different days. If you enter the filter expression into a cell on the worksheet and refer to it in the dialog box, be sure to begin the expression with a single quote so that Excel will interpret the expression as a string. Since tag names in filter expression are enclosed with single quotes, if the filter expression begins with a tagname, you must begin the expression with two single quotes when the filter expression is stored in a cell on the worksheet. Related Topics Filter Expressions (page 90) PICompDat() (page 40) PICompFilDat() (page 41) PICompDat() PICompDat(tagname, stime, etime, outcode, PIServer, mode) Arguments Argument tagname (string) stime (string) etime (string) outcode (integer) PIServer (string) mode (string) Explanation The tag for which you want compressed data. The start time in PI time format. The end time in PI time format. An output code. See Outcodes for more information on outcodes. The PI Server. The boundary type. Returns Refer to Outcodes. Page 40

45 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes Example The following retrieves compressed data points and corresponding time stamps for the tag cdf144 starting from 1:00 a.m. to 3:00 a.m. this morning from the default PI Server with inside as boundary type: =PICompDat("cdf144","1:00","3:00",1,,"inside") PICompFilDat() PICompFilDat(tagname, stime, etime, filtexp, filtcode, outcode, PIServer, mode) Arguments Argument tagname (string) stime (string) etime (string) filtexp (string) filtcode (integer) outcode (integer) PIServer (string) mode (string) Explanation The tag for which you want compressed data. The start time in PI time format. The end time in PI time format. The filter expression. See Filter Expressions (page 90) for more information on the filter expression syntax. A filter code; use 1 to return Filtered status, 0 to skip. An output code. See Outcodes for more information on outcodes. The PI Server. The boundary type. Returns Refer to Outcodes. Example The following retrieves compressed data points and the corresponding times, starting from 2:00 a.m. and ending at 10:00 a.m., for the tag cdf144 when the tag cdep158 is greater than 38: =PICompFilDat("cdf144","2:00","10:00","'cdep158'>38",1,1,,) The status Filtered is displayed for times when the filter condition is false. Data are retrieved from the default PI Server with inside as boundary type. FactoryTalk Historian Site Edition DataLink User Guide Page 41

46 Add-in to Excel Sampled Data Dialog Box This dialog box gathers evenly spaced, sampled values from the archive. If a filter expression is not specified, the PISampDat() function is called. Otherwise, the PISampFilDat() function is called. Required Fields Tagname Start Time End Time Time Interval Filter Expression If a filter expression is specified, the specified range of compressed values are retrieved from the PI Server while a given filter expression is true. If the mark as filtered option is selected, a "Filtered" status is returned for each continuous set (block) of sampled values that do not satisfy the filter expression if the tag is on a PI 3 Server. If the tag is from a PI 2 Server, a "Filtered" status is returned for each sampled value that does not satisfy the filter expression. See Fi (page 90)lter Expressions for more information on the filter expression syntax. Special Notes If you can enter the filter expression into a cell on the worksheet and refer to it in the dialog box, be sure to begin the expression with a single quote so that Excel will interpret the expression as a string. Since tagname in filter expression should be enclosed with single quotes, if the filter expression begins with a tagname, you need to begin the expression with two single quotes when the filter expression is stored in a cell on the worksheet. Related Topics Filter Expressions (page 90) PISampDat() (page 43) PISampFilDat() (page 43) PIExpDat() (page 44) Page 42

47 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes PISampDat() PISampDat(tagname, stime, etime, interval, outcode, PIServer) Arguments Argument tagname(string) stime (string) etime (string) interval (string) Explanation The tag for which you want sampled data. The start time in PI time format. The end time in PI time format. The time interval in PI time format. outcode (integer) An output code; either 0, 1, 2, or 3. PIServer (string) Returns The PI Server. Outcode Column 1 Column 2 0 Sampled data 1 Timestamps Sampled data An output code of 2 transposes the output array that results from an output code of 0 while an output code of 3 transposes the output array that results from an output code of 1. Example The following retrieves sampled data for the tag located in cell B1, from midnight yesterday to midnight today at 3-hour intervals: =PISampDat(b1,"y","t","3h",1,) Timestamps are also returned. PISampFilDat() PISampFilDat(tagname, stime, etime, interval, filtexp, filtcode, outcode, PI Server) Arguments Argument tagname(string) stime (string) etime (string) interval (string) Explanation The tag for which you want sampled data. The start time in PI time format. The end time in PI time format. The time interval in PI time format. FactoryTalk Historian Site Edition DataLink User Guide Page 43

48 Add-in to Excel Argument filtexp (string) filtcode (integer) Explanation The filter expression. See Filter Expressions (page 90) for more information on the filter expression syntax. A filter code; use 1 to return Filtered status, 0 to skip. outcode (integer) An output code; either 0, 1, 2, or 3. PIServer (string) Returns The PI Server. Outcode Column 1 Column 2 0 Sampled data 1 Timestamps Sampled data An output code of 2 transposes the output array that results from an output code of 0 and an output code of 3 transposes the output array that results from an output code of 1. Example The following formula retrieves sampled data for SINUSOID at 11-Jan-97, 11-Jan-97 1:00AM, 11-Jan-97 2:00AM, and 11-Jan-97 3:00AM: =PISampFilDat("sinusoid","11-Jan-97","+3h","1h",A1,1,1,) Timestamps are shown in column1 and values in column2. A "Filtered" status is returned for values do not satisfy the filter condition in cell A1. PIExpDat() PIExpDat(expression, stime, etime, interval, outcode, PIServer) Arguments Argument expression (string) stime (string) etime (string) interval (string) Explanation The calculation expression. See Calculation Expressions (page 87) for more information on calculation expression syntax. The start time in PI time format. The end time in PI time format. The time interval in PI time format. outcode (integer) An output code; either 0, 1, 2, or 3. PIServer (string) Returns The PI Server. Outcode Column 1 Column 2 0 Calculated data Page 44

49 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes Outcode Column 1 Column 2 1 Timestamps Calculated data An output code of 2 transposes the output array that results from an output code of 0 while an output code of 3 transposes the output array that results from an output code of 1. Example The following calculates the square root of the value of the tag sinusoid from the PI Server named THEVAX at one-hour intervals, starting from midnight yesterday to midnight today: =PIExpDat("sqr('sinusoid')","y","t","1h",1,"thevax") It also displays the timestamps. Timed Data Dialog Box This dialog box returns sampled values for a single tag that are synchronized with an array of timestamps. There are two modes to select from: Interpolated - Interpolates values at the specified timestamps except for resolution code 4 tags on PI 2 Server and tags with step attribute set on PI 3 Server. For this special case, the previous value is simply carried forward Exact Time - Retrieves the value in the archive for a specified time if an entry exists at that time. If no value exists, the message "No events found" is returned. Required Fields Tagname Timestamp. The timestamp field has to be a reference to a time array. For PI 2, the timestamps in this time array must be either monotonically increasing or monotonically decreasing. Related Topics PITimeDat() (page 46) PITimeExpDat() (page 46) FactoryTalk Historian Site Edition DataLink User Guide Page 45

50 Add-in to Excel PITimeDat() PITimeDat(tagname, timestamps, PIServer, mode) Arguments Argument tagname (string) timestamps (reference) PIServer (string) mode (string) Explanation The tag for which you the sampled data. A reference to an array of times in PI format. For PI 2, the values in this array must be either monotonically increasing or monotonically decreasing. The PI Server. The retrieval mode. Returns Sampled data. If the timestamps are in a single column, the data are returned along a single column. If the timestamps are in a single row, the data are returned along a single row. Example The following retrieves interpolated timed data for the times located in cells B1 through B12 for the tag mytag from the default PI Server: =PITimeDat("mytag",b1:b12,,"interpolated") PITimeExpDat() PITimeExpDat(expression, timestamps, PIServer) Arguments Argument Explanation expression (string) The calculation expression. See Calculation Expressions (page 87) for more information on calculation expression syntax. timestamps (reference) PIServer (string) Returns A reference to an array of times in PI format. For PI 2, the values in this array must be either monotonically increasing or monotonically decreasing. The PI Server Sampled data. If the timestamps are in a single column, the data are returned along a single column. If the timestamps are in a single row, the data are returned along a single row. Page 46

51 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes Example The following calculates the square root of the value of the tag sinusoid for the times located in cells B1 through B12 from the default PI Server: =PITimeExpDat("sqr('sinusoid')",b1:b12,) Calculated Data Dialog Box This dialog box returns a single calculated value or evenly spaced calculated values from the PI Data Archive. Calculation modes are: Total Minimum Maximum Standard deviation Range Average Count Mean All Calculation modes are time-weighted except for the mean function, which is event-weighted. Required Fields Tagname Start Time End Time Conversion Factor Calculation Mode Interval To retrieve a single calculated value, do not specify an interval and the PICalcVal() function is used. To retrieve evenly spaced calculated data, the specified interval determines the spacing of the calculation and the PICalcDat() function is used. FactoryTalk Historian Site Edition DataLink User Guide Page 47

52 Add-in to Excel Page 48

53 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes Check Box Check show pctgood if you want FactoryTalk Historian DataLink to display the percentage of the time range that contains good value. We recommend that you always look at the percent good value before using the calculation result. The percent good value is normally returned to the right of calculated value cell. If the rows checkbox is selected, the percent good value is returned at the cell below the calculated value cell. Timestamp(s) are returned when the calculation mode is minimum, maximum, or range. Mode Column 1 Column 2 Column 3 Minimum Time of min. value Minimum value Maximum Time of max. value Maximum value Range Time of min. value Time of max. value Range value Special Notes When an interval is not specified and the mode is Total, Standard Deviation, Average, Count or Mean, the timestamps are not displayed even if the Show Timestamps check box is selected. When an interval is specified and the mode is Max or Min, the timestamps displayed are the start time of each calculation interval. When the calculation is a time-weighted Total and part of the archived data within the range are bad, the reported value is equal to the calculated total value divided by the fraction of the time period with good archived data. This data normalization is equivalent to the assumption that for the bad data time range, the tag value takes on the average value of the entire range. However, this assumption may not be valid when a large fraction of the time range contains bad data. Therefore, we recommend that you always look at the percent good value before using the calculation result. The conversion factor is most often used when the calculation mode is Total and time unit of the PI tag being totalized is not the same as the server default. In all the PI 3 Servers and in most of the PI 2 Servers, the totalization default is "units per day." On the PI 2 Server, the totalization default time (totdefaulttime is the time unit in seconds) can be found in the file pilink:piparams.for. FactoryTalk Historian Site Edition DataLink User Guide Page 49

54 Add-in to Excel The following table displays the conversion factors for two of the common PI 2 Server default time units vs. various flow tag units. Flow tag unit Server default is units/day (totdefaulttime = 86400) Units/day Units/hour 24 1 Units/minute Units/second Server default is units/hour (totdefaulttime = 3600) Related Topics PICalcVal() (page 50) PICalcDat() (page 52) PICalcVal() PICalcVal(tagname, stime, etime, mode, cfactor, outcode, PIServer) Arguments Argument tagname (string) stime (string) etime (string) mode (string) cfactor (number) Explanation The tag for which you want the calculated value. The start time in PI time format. The end time in PI time format. The calculation mode (total, minimum, maximum, stdev, range, average, count or mean). A multiplicative conversion factor. Should be 1 for max, min, avg, count, mean, std and range. For more discussion of the conversion factor, see Special Notes (page 47) under Calculated Data Dialog Box (page 47). outcode (integer) An output code; 0-7 except 3. PIServer (string) Returns The PI Server. If the outcode is 0, only the calculated value is returned. Page 50

55 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes If the outcode is 1, the following applies: Mode Column 1 Column 2 Column 3 Total Total value Minimum Time of min. Value Minimum value Maximum Time of max. Value Maximum value Stdev Stdev. Value Range Time of min. Value Time of max. value Range value Average Average value Count Count value Mean Mean value An output code of 2 transposes the output array that results from an output code of 1, i.e., results are returned in rows instead of in columns. Outcode of 3 is not used. If the outcode is 4, the percent good is returned to the right of the value cell. If the outcode is 5, the following applies: Mode Column 1 Column 2 Column 3 Column 4 Total Total value Percent good Minimum Time of min. value Minimum value Percent good Maximum Time of max. value Maximum value Percent good Stdev Stdev. value Percent good Range Time of min. value Time of max. value Range value Percent good Average Average value Percent good Count Count value Percent good Mean Mean value Percent good An output code of 6 transposes the output array that results from an output code of 4, i.e., results are returned in rows instead of in columns. An output code of 7 transposes the output array that results from an output code of 5, i.e., results are returned in rows instead of in columns. FactoryTalk Historian Site Edition DataLink User Guide Page 51

56 Add-in to Excel Example The following calculates a time-weighted total for the tag cdf144 from yesterday to today from the default PI Server: =PICalcVal("cdf144","y","t","total",1440,4,) The result is multiplied by The percent good is returned next to the total. PICalcDat() PICalcDat(tagname, stime, etime, interval, mode, cfactor, outcode, PIServer) Arguments Argument tagname (string) stime (string) etime (string) interval (string) mode (string) cfactor (number) Explanation The tag for which you want the calculated data. The start time in PI time format. The end time in PI time format. The time interval in PI time format. outcode (integer) An output code; 0-7. PIServer (string) Returns The calculation mode (total, minimum, maximum, stdev, range, average, count or mean). A multiplicative conversion factor. Should be 1 for max, min, avg, count, mean, std and range. For more discussion of the conversion factor, see Special Notes (page 47) under Calculated Data Dialog Box (page 47). The PI Server. The outcode affects the output as follows: Calculated values along a column Timestamps and values along 2 columns Calculated values along a row Timestamps and values along 2 rows Values and pctgood along 2 columns Timestamps, values, and pctgood along 3 columns Values and pctgood along 2 rows Timestamps, values, and pctgood along 3 rows Page 52

57 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes Example The following retrieves totals for the tag located in cell B1, from midnight yesterday to midnight today at 3-hour intervals from the default PI Server specified in the PILogin.ini file: =PICalcDat(b1,"y","t","3h","total",24,1,) Timestamps are also returned. The values are multiplied by 24 before they are displayed in the spreadsheet. Advanced Calculated Data Dialog Box This dialog box returns a single calculated value or evenly spaced calculated values from the PI Data Archive. Calculation modes are: Total Minimum Maximum Standard deviation Range Average Count Required Fields Tagname or Expression. See Calculation Expressions (page 87) for more information on calculation expression syntax. Start Time End Time Conversion Factor Calculation Mode Filter Expression If a filter expression is specified, the requested summaries on the source point are calculated for the time ranges where the expression evaluates to true. See Filter Expressions (page 90) for more information on the filter expression syntax. FactoryTalk Historian Site Edition DataLink User Guide Page 53

58 Add-in to Excel Interval To retrieve a single calculated value, do not specify an interval. To retrieve evenly spaced calculated data, the specified interval determines the spacing of the calculation. Expression Sampling Mode There are 3 expression sampling modes for sampling the filter expression: Pt. Compressed (default) - Evaluates the filter expression at the timestamp of any compressed value of the source point Exp. Compressed - Evaluates the filter expression at the timestamp of any compressed values of any tags in the filter expression Interpolated - Evaluates the filter expression at evenly spaced sampling intervals There are 2 expression sampling modes for sampling the expression to be summarized: Compressed (default) - Evaluates the expression at the timestamp of any compressed values of any tags in the expression Interpolated - Evaluates the expression at evenly spaced sampling intervals Expression Sampling Interval If Expression Sampling Mode is specified as interpolated, the specified expression sampling interval determines the spacing at which the expression is evaluated. If the Expression Sampling Mode is not interpolated, then the expression sampling interval is ignored. Calculation Basis There are 2 types of calculation basis: Time-Weighted (default) - Weights the values in the calculation by the time over which they apply. Event-Weighted - Weights each event with the same weight. There must be at least one event within the time range to perform a successful calculation. For standard deviation, two events are required. Page 54

59 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes Minimum Percent Good The minimum percent good is the minimum percentage of good data over the time range at which data will be returned instead of an error "Insufficient good data." Check Box Refer to the Check Box description under Calculated Data Dialog Box (page 47). Special Notes Refer to the Special Notes section under Calculated Data Dialog Box (page 47). Related Topics Filter Expressions (page 90) PIAdvCalcVal() (page 56) PIAdvCalcFilVal() (page 57) PIAdvCalcExpVal() (page 58) PIAdvCalcExpFilVal() (page 59) PIAdvCalcDat() (page 60) PIAdvCalcFilDat() (page 60) PIAdvCalcExpDat() (page 62) PIAdvCalcExpFilDat() (page 63) FactoryTalk Historian Site Edition DataLink User Guide Page 55

60 Add-in to Excel PIAdvCalcVal() PIAdvCalcVal(tagname, stime, etime, mode, calcbasis, minpctgood, cfactor, outcode, PIServer) Arguments Argument tagname (string) stime (string) etime (string) mode (string) calcbasis (integer) minpctgood (number) Cfactor (number) Explanation The tag for which you want the calculated value. The start time in PI time format. The end time in PI time format. The calculation mode (total, minimum, maximum, stdev, range, average, count or mean). The calculation basis. 0 for time-weighted; 1 for event-weighted. Minimum percentage of good data over time range A multiplicative conversion factor. Should be 1 for max, min, avg, count, mean, std and range. For more discussion of the conversion factor, see Special Notes (page 47) under Calculated Data Dialog Box (page 47). outcode (integer) An output code; 0-7 except 3. PIServer (string) Returns The PI Server. Refer to Returns section for PICalcVal() (page 50) function. Example The following calculates a time-weighted total for the tag cdf144 from yesterday to today from the default PI Server: =PIAdvCalcVal("cdf144","y","t","total",0,50,1,4,) The result is multiplied by 1. The minpctgood is 50 percent so result will only be displayed if percent good is 50 percent or greater. The percent good is returned next to the total. Page 56

61 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes PIAdvCalcFilVal() PIAdvCalcFilVal(tagname, stime, etime, filtexp, mode, calcbasis, sampmode, sampinterval, minpctgood, cfactor, outcode, PIServer) Arguments Argument tagname (string) stime (string) etime (string) filtexp (string) mode (string) calcbasis (integer) sampmode (string) sampinterval (string) minpctgood (number) Cfactor (number) Explanation The tag for which you want the calculated value. The start time in PI time format. The end time in PI time format. The filter expression. See Filter Expressions (page 90) for more information on the filter expression syntax. The calculation mode (total, minimum, maximum, stdev, range, average, count or mean). The calculation basis. 0 for time-weighted; 1 for event-weighted. The sampling mode (pt. compressed, exp. compressed or interpolated). The sampling interval in PI time format. Minimum percentage of good data over time range. A multiplicative conversion factor. Should be 1 for max, min, avg, count, mean, std and range. For more discussion of the conversion factor, see Special Notes (page 47) under Calculated Data Dialog Box (page 47). outcode (integer) An output code; 0-7 except 3. PIServer (string) The PI Server. Returns Refer to Returns section for PICalcVal() (page 50) function. Example The following calculates a time-weighted total for the tag cdf144 from yesterday to today during the time periods when tag cdm158 is in Manual from the default PI Server: =PIAdvCalcFilVal("cdf144","y","t","'cdm158'=""Manual""","total",0, "pt. compressed","10m",50,1,4,) The result is multiplied by 1. Since pt.compressed is the specified sampling mode, the sampling interval is ignored and the filter expression will be sampled at the compressed FactoryTalk Historian Site Edition DataLink User Guide Page 57

62 Add-in to Excel events of cdf144. The minpctgood is 50 percent so result will only be displayed if percent good is 50 percent or greater. The percent good is returned next to the total. PIAdvCalcExpVal() PIAdvCalcExpVal(expression, stime, etime, mode, calcbasis, sampmode, sampinterval, minpctgood, cfactor, outcode, PIServer) Arguments Argument expression (string) stime (string) etime (string) mode (string) calcbasis (integer) sampmode (string) sampinterval (string) minpctgood (number) cfactor (number) Explanation The expression for which you want the calculated value. The start time in PI time format. The end time in PI time format. The calculation mode (total, minimum, maximum, stdev, range, average, count or mean). The calculation basis. 0 for time-weighted; 1 for event-weighted. The sampling mode (compressed or interpolated). The sampling interval in PI time format. Minimum percentage of good data over time range. A multiplicative conversion factor. Should be 1 for max, min, avg, count, mean, std and range. For more discussion of the conversion factor, see Special Notes (page 47) under Calculated Data Dialog Box (page 47). outcode (integer) An output code; 0-7 except 3. PIServer (string) Returns The PI Server. Refer to Returns section for PICalcVal() (page 50) function. Example The following calculates a time-weighted total for the expression 'cdf144'+' cdt158' from yesterday to today from the default PI Server: =PIAdvCalcExpVal("'cdf144'+'cdt158'","y","t","total",0,"compressed ","10m",0,1,4,) The result is multiplied by 1. Since compressed is the specified sampling mode, the sampling interval is ignored and the expression will be sampled at the combined compressed events of cdf144 and cdt158. The minpctgood is 50 percent so result will only be displayed if percent good is 50 percent or greater. The percent good is returned next to the total. Page 58

63 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes PIAdvCalcExpFilVal() PIAdvCalcExpFilVal(expression, stime, etime, filtexp, mode, calcbasis, sampmode, sampinterval, minpctgood, cfactor, outcode, PIServer) Arguments Argument expression (string) stime (string) etime (string) filtexp (string) mode (string) calcbasis (integer) sampmode (string) sampinterval (string) minpctgood (number) cfactor (number) Explanation The expression for which you want the calculated value. The start time in PI time format. The end time in PI time format. The filter expression. See Filter Expressions (page 90) for more information on the filter expression syntax. The calculation mode (total, minimum, maximum, stdev, range, average, count or mean). The calculation basis. 0 for time-weighted; 1 for event-weighted. The sampling mode (compressed or interpolated). The sampling interval in PI time format. Minimum percentage of good data over time range. A multiplicative conversion factor. Should be 1 for max, min, avg, count, mean, std and range. For more discussion of the conversion factor, see Special Notes (page 47) under Calculated Data Dialog Box (page 47). outcode (integer) An output code; 0-7 except 3. PIServer (string) Returns The PI Server. Refer to Returns section for PICalcVal() (page 50) function. Example The following calculates a time-weighted total for the expression 'cdf144'+' cdt158' when 'productid' = "Product2" from yesterday to today from the default PI Server: =PIAdvCalcExpFilVal("'cdf144'+'cdt158'","y","t","'productid'="Prod uct2"", "total",0,"compressed","10m",0,1,4,) The result is multiplied by 1. Since compressed is the specified sampling mode, the sampling interval is ignored and the expression will be sampled at the combined compressed events of cdf144 and cdt158. The minpctgood is 50 percent so result will only be displayed if percent good is 50 percent or greater. The percent good is returned next to the total. FactoryTalk Historian Site Edition DataLink User Guide Page 59

64 Add-in to Excel PIAdvCalcDat() PIAdvCalcDat(tagname, stime, etime, interval, mode, calcbasis, minpctgood, cfactor, outcode, PIServer) Arguments Argument tagname (string) stime (string) etime (string) interval (string) mode (string) calcbasis (integer) Explanation The tag for which you want the calculated data. The start time in PI time format. The end time in PI time format. The time interval in PI time format. The calculation mode (total, minimum, maximum, stdev, range, average, count or mean). The calculation basis. 0 for time-weighted; 1 for event-weighted. minpctgood (number) Minimum percentage of good data over time range. cfactor (number) outcode (integer) An output code; 0-7. PIServer (string) Returns A multiplicative conversion factor. Should be 1 for max, min, avg, count, mean, std and range. For more discussion of the conversion factor, see Special Notes (page 47) under Calculated Data Dialog Box (page 47). The PI Server. Refer to Returns section for PICalcDat() (page 52) function. Example The following retrieves totals for the tag cdf144, from midnight yesterday to midnight today at 3-hour intervals from the default PI Server: =PIAdvCalcDat("cdf144","y","t","3h","total",0,50,1,4,) The result is multiplied by 1. The minpctgood is 50 percent so result will only be displayed if percent good is 50 percent or greater. The percent good is returned next to the total. PIAdvCalcFilDat() PIAdvCalcFilDat(tagname, stime, etime, interval, filtexp, mode, calcbasis, sampmode, sampinterval, minpctgood, cfactor, outcode, PIServer) Page 60

65 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes Arguments Argument tagname (string) stime (string) etime (string) interval (string) filtexp (string) mode (string) calcbasis (integer) sampmode (string) sampinterval (string) minpctgood (number) cfactor (number) Explanation The tag for which you want the calculated data. The start time in PI time format. The end time in PI time format. The time interval in PI time format. The filter expression. See Filter Expressions (page 90) for more information on the filter expression syntax. The calculation mode (total, minimum, maximum, stdev, range, average, count or mean). The calculation basis. 0 for time-weighted; 1 for event-weighted. The sampling mode (pt. compressed, exp. compressed or interpolated). The sampling interval in PI time format. outcode (integer) An output code; 0-7. PIServer (string) Returns Minimum percentage of good data over time range. A multiplicative conversion factor. Should be 1 for max, min, avg, count, mean, std and range. For more discussion of the conversion factor, see Special Notes (page 47) under Calculated Data Dialog Box (page 47). The PI Server. Refer to Returns section for PICalcDat() (page 52) function. Example The following retrieves totals for the tag cdf144, from midnight yesterday to midnight today at 3-hour intervals during the time periods when tag cdf144 is in Manual from the default PI Server: =PIAdvCalcFilDat("cdf144","y","t","3h","'cdm158'=""Manual""","tota l",0,"pt. compressed","10m",50,1,4,) The result is multiplied by 1. Since pt.compressed is the specified sampling mode, the sampling interval is ignored and the filter expression will be sampled at the compressed events of cdf144. The percent good is returned next to the total. FactoryTalk Historian Site Edition DataLink User Guide Page 61

66 Add-in to Excel PIAdvCalcExpDat() PIAdvCalcExpDat(expression, stime, etime, interval, mode, calcbasis, sampmode, sampinterval, minpctgood, cfactor, outcode, PIServer) Arguments Argument expression (string) stime (string) etime (string) interval (string) mode (string) calcbasis (integer) sampmode (string) sampinterval (string) minpctgood (number) cfactor (number) Explanation The expression for which you want the calculated data. The start time in PI time format. The end time in PI time format. The time interval in PI time format. The calculation mode (total, minimum, maximum, stdev, range, average, count or mean). The calculation basis. 0 for time-weighted; 1 for event-weighted. The sampling mode (compressed or interpolated). The sampling interval in PI time format. outcode (integer) An output code; 0-7. PIServer (string) Returns Minimum percentage of good data over time range. A multiplicative conversion factor. Should be 1 for max, min, avg, count, mean, std and range. For more discussion of the conversion factor, see Special Notes (page 47) under Calculated Data Dialog Box (page 47). The PI Server. Refer to Returns section for PICalcDat() (page 52) function. Example The following retrieves totals for the expression 'cdf144'+'cdt158', from midnight yesterday to midnight today at 3-hour intervals from the default PI Server: =PIAdvCalcExpDat("'cdf144'+'cdt158'","y","t","3h","total",0,"compr essed", "10m",50,1,4,) The result is multiplied by 1. Since compressed is the specified sampling mode, the sampling interval is ignored and the expression will be sampled at the combined compressed events of cdf144 and cdt158. The minpctgood is 50 percent so result will only be displayed if percent good is 50 percent or greater. The percent good is returned next to the total. Page 62

67 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes PIAdvCalcExpFilDat() PIAdvCalcExpFilDat(expression, stime, etime, interval, filtexp, mode, calcbasis, sampmode, sampinterval, minpctgood, cfactor, outcode, PIServer) Arguments Argument expression (string) stime (string) etime (string) interval (string) filtexp (string) mode (string) calcbasis (integer) sampmode (string) sampinterval (string) minpctgood (number) cfactor (number) Explanation The expression for which you want the calculated value. The start time in PI time format. The end time in PI time format. The time interval in PI time format. The filter expression. See Filter Expressions (page 90) for more information on the filter expression syntax. The calculation mode (total, minimum, maximum, stdev, range, average, count or mean). The calculation basis. (time-weighted or event-weighted). The sampling mode (compressed or interpolated). The sampling interval in PI time format. Minimum percentage of good data over time range. A multiplicative conversion factor. Should be 1 for max, min, avg, count, mean, std and range. For more discussion of the conversion factor, see Special Notes (page 47) under Calculated Data Dialog Box (page 47). outcode (integer) An output code; 0-7 except 3. PIServer (string) Returns The PI Server. Refer to Returns section for PICalcDat() (page 52) function. Example The following calculates a time-weighted total for the expression 'cdf144'+' cdt158' when 'productid' = "Product2" at 3-hour intervals from yesterday to today from the default PI Server: =PIAdvCalcExpFilDat("'cdf144'+'cdt158'","y","t","3h","'productid'= "Product2"","total",time-weighted,"compressed","10m",0,1,4,) The result is multiplied by 1. Since compressed is the specified sampling mode, the sampling interval is ignored and the expression will be sampled at the combined compressed events of cdf144 and cdt158. The minpctgood is 50 percent so result will only be displayed if percent good is 50 percent or greater. The percent good is returned next to the total. FactoryTalk Historian Site Edition DataLink User Guide Page 63

68 Add-in to Excel Time Filtered Dialog Box This dialog box returns the amount of time for which a given expression is true over a specified time range. The user can specify multiple time ranges as evenly space intervals as in the Calculated Data dialog box. Required Fields Expression. See Calculation Expressions (page 87) for more information on calculation expression syntax. Start Time End Time Time units (default to seconds) Special Notes If you can enter the expression into a cell on the worksheet and refer to it in the dialog box, begin the expression with a single quote so that Excel will interpret the expression as a string. Since a tagname in a filter expression should be enclosed with single quotes, begin the expression with two single quotes when the expression is stored in a cell on the worksheet if the expression begins with a tagname. Related Topics Calculation Expressions (page 87) PITimeFilterVal() (page 65) PITimeFilter() (page 66) Page 64

69 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes PITimeFilterVal() PITimeFilterVal(expression, stime, etime, timeunit, outcode, PIServer) Arguments Argument expression (string) stime (string) etime (string) timeunit (string) Explanation The calculation expression. See Calculation Expressions (page 87) for more information on calculation expression syntax. The start time in PI time format. The end time in PI time format. Unit of time for the result to be displayed. Valid entries are: seconds, minutes, hours and days. outcode (integer) An output code; 0-7 except 3. PIServer (string) The PI Server. Returns If the outcode is 0, 1, or 2 only the calculated value is returned. Outcode of 3 is not used. If the outcode is 4 or 5, the percent good is returned to the right of the value cell. If the outcode is 6 or 7, the percent good is returned below the value cell. Example The following calculates the amount of time that the expression from cell $A$1 is true from the PI Server named THEVAX, starting from midnight yesterday to midnight today: =PITimeFilterVal($A$1,"y","t","seconds",1,"thevax") The calculation result is expressed in seconds. FactoryTalk Historian Site Edition DataLink User Guide Page 65

70 Add-in to Excel PITimeFilter() PITimeFilter(expression, stime, etime, interval, timeunit, outcode, PIServer) Arguments Argument expression (string) stime (string) etime (string) interval (string) timeunit (string) Explanation The calculation expression. See Calculation Expressions (page 87) for more information on calculation expression syntax. The start time in PI time format. The end time in PI time format. The time interval in PI time format. outcode (integer) An output code; 0-7. PIServer (string) Unit of time for the result to be displayed. Valid entries are: seconds, minutes, hours and days. The PI Server. Returns Outcode Column 1 Column 2 0 Calculated data 1 Timestamps Calculated data An output code of 2 transposes the output array that results from an output code of 0 and an output code of 3 transposes the output array that results from an output code of 1. Example The following calculates the amount of time that the expression from cell $A$1 is true from the PI Server named THEVAX at one-hour intervals, starting from midnight yesterday to midnight today: =PITimeFilter($A$1,"y","t","1h","seconds",1,"thevax") It also displays the timestamps for the start time of each calculation interval. The calculation result is expressed in seconds. Page 66

71 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes Point ID to Tag Dialog Box This dialog box returns the tagname from the specified point ID. Required Fields Point ID Related Topics PIPointIDToTag() (page 67) PIPointIDToTag() PIPointIDToTag(pointid, PIServer) Arguments Argument pointid (string) PIServer (string) Explanation Unique internal ID number not reused upon deletion of a point. The PI Server. Returns Tagname Example The following returns the tagname of the tag with point ID of 123 from server named THEVAX. =PIPointIDToTag("123","thevax") Attribute Mask to Tag Dialog Box This dialog box returns a list of tags which match the tag attribute masks specified. FactoryTalk Historian Site Edition DataLink User Guide Page 67

72 Add-in to Excel Required Fields Tagname Descriptor Point Source Point Type Point Class Engineering Units Related Topics PIAttributeMaskToTag () (page 68) PIAttributeMaskToTag () PIAttributeMaskToTag(tagname, descriptor, pointsource, pointtype, pointclass, engunits, outcode, PIServer) Arguments Argument tagname (string) descriptor (string) pointsource (string) pointtype (string) pointclass (string) engunits (string) Explanation Tagname mask. Descriptor mask. Point Source mask. Point Type mask. Point Class mask. Engineering Units mask. outcode (integer) An output code; either 0 or 2. PIServer (string) Returns The PI Server. Outcode Column 1 Column 2 0 Tagname An output code of 2 transposes the output array that results from an output code of 1. Page 68

73 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes Example The following returns the tagname of the tags which start with "sin" from server named THEVAX. =PIAttributeMaskToTag("sin*","*","*","*","*","*",0,"thevax") Alias Dialog Box This dialog box returns a tagname when an alias is specified. Required Fields Alias Module Path Query Date Related Topics PIAliasToTag() (page 69) PIAliasToTag() PIAliasToTag(alias, modulepath, querydate, outcode, PIServer) Arguments Argument Explanation alias (string) Module item that is a reference to a PI point. modulepath (string) Full path to a module in module database. querydate (integer) Query for modules with effective dates at or after this date. Outcode (integer) An output code; either 0, 1, or 2. PIServer (string) The PI Server. Returns Outcode Column 1 Column 2 0 Tagname 1 Tagname Server of tag FactoryTalk Historian Site Edition DataLink User Guide Page 69

74 Add-in to Excel An output code of 2 transposes the output array that results from an output code of 1. Example The following returns the tagname corresponding to the "Temperature" alias of module "Reactor1" which is a submodule of "Unit1". "Unit1" is at the root of the module database for a PI server named THEVAX. The module database is queried at current time. =PIAliasToTag("Temperature","\Unit1\Reactor1","*",0,"thevax") Property Dialog Box This dialog box returns a value when a property is specified. Required Fields Property Module Path Query Date Related Topics PIPropertyToValue() (page 70) PIPropertyToValue() PIPropertyToValue(property, modulepath, querydate, PIServer, outcode) Arguments Argument Explanation Property (string) Module item that has value of virtually anything. modulepath (string) Full path to a module in module database. querydate (integer) Query for modules with effective dates at or after this date. PIServer (string) The PI Server. Outcode (integer) An output code; either 0 or 2. Page 70

75 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes Returns An output code of 0 displays the value of the property in a column. An output code of 2 displays the value of the property in a row. Example The following returns the value corresponding to the "Implementer" property of module "Reactor1" which is a submodule of "Unit1". "Unit1" is at the root of the module database for a PI server named THEVAX. The module database is queried at current time. =PIPropertyToValue("Implementer","\Unit1\Reactor1","*","thevax") Insert Trend Control The Trend Control is an ActiveX control that can be inserted onto any Excel spreadsheet. The trend can display data from both the spreadsheet and a PI Server tag. FactoryTalk Historian Site Edition DataLink User Guide Page 71

76 Add-in to Excel To create a trend, a trend wizard is provided to make inserting trends easier. There are two sources of data that the Trend Control can plot: Worksheet Data PI Data Data on Worksheet The Trend Wizard can be used to create a trend from data on an Excel worksheet. If the data is to come from the worksheet, the cell range of the data must be specified. The cell range can be typed in manually or the mouse can be used to specify the range. To use the mouse to specify the range, click button at the right of the field. Another dialog box will appear. Selecting the range on the spreadsheet will generate the cell reference format in the dialog box. The First element is trace name option is used if a name is to be provided for the trace on the trend. If this option is specified, the string in the first cell is used for the name of the trace. The first cell is the cell above the first value of the range if the data is arranged in the column format. If the data is arranged in the row format, then the first cell is the cell to the left of the first value of the range. For ease of use with FactoryTalk Historian DataLink functions, the Include all cells in array option is specified as the default. If this option is specified, then only one cell of the array must be specified for the cell range. The rest of the array is automatically added to the cell range reference when the Add -> button is selected. Page 72

77 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes The Plot as stepped data option gives the trace a jagged-saw look. This option is usually specified for discrete tags. Data from PI The Trend Wizard can also be used to create a trend from data directly from the PI Server. To get data directly from the PI Server, the tagname needs to be specified. The tagname can be conveniently searched for from the point database of the PI Server. By pressing the Search... button, a Tag Search dialog box appears. This is the same Tag Search dialog box as the one that comes from the PI menu. Any tags selected from the Tag Search dialog box are automatically added to the list of traces. By default DataLink displays color-blind markers to differentiate traces on monochrome viewers; color-blind markers are evenly spaced along a trace and do not indicate archived data points. Select the Markers checkbox to display markers that indicate the location of archived data points on the trace. Another way of specifying tags is by cell reference. If the tag names are on the Excel spreadsheet, they can be referenced by checking the Cell Ref option box and specifying the cell(s) where the tagname(s) are. The server name can be specified in the same way. After clicking Next, the start time and end time of the trend needs to be specified in PI time format. FactoryTalk Historian Site Edition DataLink User Guide Page 73

78 Add-in to Excel Trend Title and Placement The last screen is to configure the trend title and the placement of the trend. If a new worksheet is selected, the trend is placed on a blank worksheet at the top left corner. To display value attribute icons at the top of the trend, select the Show Value Attributes checkbox; icons appear when the range of data contains events that have the Questionable, Substituted, or Annotated bits set. If the existing worksheet option is specified, then the cell where the trend is to be placed must be specified. The selected cell before entering the trend wizard is the default cell reference. Make sure to choose a cell, which does not contain data. If the cell references a cell containing data, the trend will cover the data. However, the data is not deleted. To move the trend, right-click the trend and select Move/Resize. Page 74

79 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes Right Click Menu After inserting the trend into the Excel worksheet, quick changes can be made to it by selecting some of the items on the right click menu. To change the y-axis scaling, the Change Scale... option can be selected. There you can change both the time range and y-axis of the trend. If a change in the scale is deemed undesirable, the Revert option can be selected to undo the changed made. The Revert option always reverts back to the settings defined in the Trend Wizard. To scroll through time, scroll bars can be enabled with the Scroll Bar option. The scroll bar appears at the bottom of the trend. Again, the Revert option can be used to undo changes made by the scroll bar. To change the format of the trace or the trend itself, the Format... option can be used. FactoryTalk Historian Site Edition DataLink User Guide Page 75

80 Add-in to Excel For instance, this option can be used to change the color or line thickness of a trace. Also it can be used to add legends to the trend. Define Trend... and Define Trend Time Range... brings back the Trend Wizard screens. Delete Trend option deletes the trend. Export Data... option pastes the values used to plot the trend onto the spreadsheet. The Move/Resize option moves and changes the trend to size of the specified cell range. The Copy/Paste option copies the trend to the clipboard and then prompts for the destination of the paste. The pasted trend is a copy of the trend in terms of all its formatting and references to cells. Additional Information For additional information on the use of the trend control, you can press the Help button on the Trend Wizard. Also there are additional help files in...\pipc\help\pitrend*. For instance, to learn more about Automation of the trend control, there is a...\pipc\help\pitrendauto.hlp. Page 76

81 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes Tag Search Dialog Box This dialog box allows you to search for tags from your PI Server(s) and copy the results into the spreadsheet. To copy tags from the result list, you must first select each tag by clicking on the tagname while holding the CTRL key. To select an entire range of tags, click the first tag, then hold the SHIFT key and click the tag at the bottom of the range. Click OK to copy tags to the spreadsheet. If the "Copy PIServer Name" option in the Settings... dialog box is checked, the PI Server for each tag will be copied into the spreadsheet along with the tag names. Tags are copied into the spreadsheet either along a single column or along a single row depending on the option selected in the "Copy items to sheet" section of the FactoryTalk Historian DataLink Settings... dialog. The starting position where the copying takes place is the current cell. If the "Copy PIServer Name" option is enabled, the server names are copied into the spreadsheet in a column to the right of the tag names when the In a column option is selected in the "Copy items to sheet" section. If the In a row option is selected in the "Copy items to sheet" section, the server names are copied below the tag names in the spreadsheet. FactoryTalk Historian Site Edition DataLink User Guide Page 77

82 Add-in to Excel Module Database Dialog Box This dialog box allows you to search for aliases, properties, and modules from your PI Server(s) and copy the results into the spreadsheet. The dialog box mostly consists of a tree view of the module database. The dialog box enables users to copy module database items to the spreadsheet. The tree view displays three types of module database items. Aliases Properties Modules Page 78

83 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes There are two ways to select aliases and properties from the module database with each method copying a different set of items to the spreadsheet. Selecting just one item copies that item to the spreadsheet. Selecting "Aliases" or "Properties" item of a module copies all aliases or properties of that module respectively. If the "copy module path" option is checked, the full module path of the alias or property is copied to the spreadsheet along with the alias or property in an adjacent cell. To select a module, selecting just the one module and selecting copy module path will copy that module's full path to the spreadsheet. If the copy module path checkbox is not checked, then just the name of the module is pasted to the spreadsheet. The PI Server drop-down list can be used to switch between module databases of different PI servers. The query date field can be used to specify the date and time context of the displayed module database. If the "Copy PIServer Name" option in the Settings... dialog-box is checked, the PI server for each module database item will be copied into the spreadsheet along with the module database item. Connections Dialog Box A dialog box manages your PI Server connections. FactoryTalk Historian Site Edition DataLink User Guide Page 79

84 Add-in to Excel By using the right click menu, you can add additional PI Servers to the list, edit existing PI Servers, remove existing PI Servers, and set an existing PI Server as the default PI Server. You can click on the checkbox to connect to and disconnect from PI Servers in the list. After you successfully connect to a PI Server, the Status field changes to checked, the user column returns the user that the connection is connected as, and the PI version column returns the version of the PI server that it connected to. Settings Dialog Box This dialog box controls your settings and preferences for FactoryTalk Historian DataLink. Page 80

85 Details for FactoryTalk Historian DataLink Functions and Dialog Boxes The set of radio buttons In a row or In a column determines whether the selected tags in the TagSearch dialog box are copied to the spreadsheet along a row or a column. The Copy PIServer name check box determines whether the PI Server's name is copied into the PIServer edit field if TagSearch is called from a PI dialog box. This option also determines whether the server names are copied into the spreadsheet for selected tags if TagSearch is called directly from the PI menu. The Use PIServer Time Zone check box determines whether or not all the DataLink functions interpret time using the PI server time zone instead of the client machine time zone information. This option affects systems where the PI 3 Server machine has different time zone settings than the client machine. The Display #N/A instead of Blanks check box determines whether or not "#N/A" or blanks are displayed when there is less data than the size of the DataLink function array. Select this check box when the DataLink function results are plotted by the Excel charting package. The Locale Independent check box determines whether localized time strings should be used when parsing time data. FactoryTalk Historian Site Edition DataLink User Guide Page 81

The following logos and products are trademarks of OSIsoft, Inc.: PI System, Sequencia, Sigmafine, grecipe, srecipe, and RLINK.

The following logos and products are trademarks of OSIsoft, Inc.: PI System, Sequencia, Sigmafine, grecipe, srecipe, and RLINK. Contact Rockwell Customer Support Telephone 1.440.646.3434 Online Support http://support.rockwellautomation.com Copyright Notice 2007 Rockwell Automation Technologies, Inc. All rights reserved. Printed

More information

INSTALLATION ASSISTANT. Rockwell Automation Publication HSE-QR002A-EN-E December 2012

INSTALLATION ASSISTANT. Rockwell Automation Publication HSE-QR002A-EN-E December 2012 INSTALLATION ASSISTANT Rockwell Automation Publication HSE-QR002A-EN-E December 2012 Supersedes Publication HSE-QR001A-EN-E May 2012 Contact Rockwell Automation Copyright Notice Trademark Notices Other

More information

The following logos and products are trademarks of OSIsoft, Inc.: PI System, Sequencia, Sigmafine, grecipe, srecipe, and RLINK.

The following logos and products are trademarks of OSIsoft, Inc.: PI System, Sequencia, Sigmafine, grecipe, srecipe, and RLINK. Contact Rockwell Customer Support Telephone 1.440.646.3434 Online Support http://support.rockwellautomation.com Copyright Notice 2007 Rockwell Automation Technologies, Inc. All rights reserved. Printed

More information

AssetCentre. Asset Management INSTALLATION GUIDE INTEGRATED PRODUCTION & PERFORMANCE SUITE

AssetCentre. Asset Management INSTALLATION GUIDE INTEGRATED PRODUCTION & PERFORMANCE SUITE INTEGRATED PRODUCTION & PERFORMANCE SUITE AssetCentre Asset Management INSTALLATION GUIDE PUBLICATION FTAC-IN002D-EN-E November 2008 Supersedes Publication FTAC-IN002C-EN-E Contact Rockwell Customer Support

More information

Ethernet is a registered trademark of Digital Equipment Corporation, Intel, and Xerox Corporation.

Ethernet is a registered trademark of Digital Equipment Corporation, Intel, and Xerox Corporation. Contact Rockwell Automation Customer Support Telephone 1.440.646.3434 Online Support http://support.rockwellautomation.com Copyright Notice 2007 Rockwell Automation Technologies, Inc. All rights reserved.

More information

USER GUIDE. Rockwell Automation Publication RSSQL-UM001I-EN-P-June 2014

USER GUIDE. Rockwell Automation Publication RSSQL-UM001I-EN-P-June 2014 USER GUIDE Rockwell Automation Publication RSSQL-UM001I-EN-P-June 2014 Supersedes Publication RSSQL-UM001H-EN-P-April 2011 Contacting Rockwell Copyright Notice Trademark Notices Other Trademarks Warranty

More information

INSTALLATION AND CONFIGURATION GUIDE. Rockwell Automation Publication HSE-IN024A-EN-E December 2012

INSTALLATION AND CONFIGURATION GUIDE. Rockwell Automation Publication HSE-IN024A-EN-E December 2012 INSTALLATION AND CONFIGURATION GUIDE Rockwell Automation Publication HSE-IN024A-EN-E December 2012 Supersedes Publication HSE-IN023A-EN-E May 2012 Contact Rockwell Automation Copyright Notice Trademark

More information

Last Revised: January 13, :16:43

Last Revised: January 13, :16:43 Contact Rockwell Customer Support Telephone 1.440.646.3434 Online Support http://www.rockwellautomation.com/support/ Copyright Notice 2010 Rockwell Automation Technologies, Inc. All rights reserved. Printed

More information

USER GUIDE. Rockwell Automation Publication HIST-UM001K-EN-E-June 2014

USER GUIDE. Rockwell Automation Publication HIST-UM001K-EN-E-June 2014 USER GUIDE Rockwell Automation Publication HIST-UM001K-EN-E-June 2014 Supersedes Publication HIST-UM001J-EN-P-December 2011 Contacting Rockwell Copyright Notice Trademark Notices Other Trademarks Warranty

More information

Historian SE PROCESSBOOK USER S GUIDE

Historian SE PROCESSBOOK USER S GUIDE Historian SE PROCESSBOOK USER S GUIDE PUBLICATION HSEPB-UM020A-EN-E September 2007 Contact Rockwell Customer Support Telephone 1.440.646.3434 Online Support http://support.rockwellautomation.com Copyright

More information

RSLinx Enterprise GETTING RESULTS GUIDE. PUBLICATION LNXENT-GR001F-EN-E August 2010 Supersedes Publication LNXENT-GR001E-EN-E

RSLinx Enterprise GETTING RESULTS GUIDE.  PUBLICATION LNXENT-GR001F-EN-E August 2010 Supersedes Publication LNXENT-GR001E-EN-E RSLinx Enterprise GETTING RESULTS GUIDE PUBLICATION LNXENT-GR001F-EN-E August 2010 Supersedes Publication LNXENT-GR001E-EN-E Contact Rockwell Customer Support Telephone 1.440.646.3434 Online Support http://www.rockwellautomation.com/support/

More information

MetricLineEdition. Performance & Visibility ADMINISTRATOR S GUIDE INTEGRATED PRODUCTION & PERFORMANCE SUITE

MetricLineEdition. Performance & Visibility ADMINISTRATOR S GUIDE INTEGRATED PRODUCTION & PERFORMANCE SUITE INTEGRATED PRODUCTION & PERFORMANCE SUITE Performance & Visibility MetricLineEdition ADMINISTRATOR S GUIDE PUBLICATION FTMLE-IN001A-EN-P August 2008 Supersedes Publication FTMLE-IN001A-EN-E Contact Rockwell

More information

INSTALLATION AND CONFIGURATION GUIDE. Rockwell Automation Publication HSE-IN025D-EN-E August 2018

INSTALLATION AND CONFIGURATION GUIDE. Rockwell Automation Publication HSE-IN025D-EN-E August 2018 INSTALLATION AND CONFIGURATION GUIDE Rockwell Automation Publication HSE-IN025D-EN-E August 2018 Supersedes Publication HSE-IN025C-EN-E February 2017 Preface Copyright notice End User License Agreement

More information

INSTALLATION AND CONFIGURATION GUIDE. Rockwell Automation Publication HSE-IN025C-EN-E February 2017

INSTALLATION AND CONFIGURATION GUIDE. Rockwell Automation Publication HSE-IN025C-EN-E February 2017 INSTALLATION AND CONFIGURATION GUIDE Rockwell Automation Publication HSE-IN025C-EN-E February 2017 Supersedes Publication HSE-IN025B-EN-E December 2015 Legal Notices Copyright Notice End User License Agreement

More information

RSBizWare BatchCampaign

RSBizWare BatchCampaign RSBizWare BatchCampaign USER S GUIDE PUBLICATION BWCMP-UM009A-EN-P August 2007 Supersedes Publication BWCMP-UM008A-EN-P Contact Rockwell Customer Support Telephone 1.440.646.3434 Online Support http://www.rockwellautomation.com/support/

More information

ii RSBatch Equipment Editor User s Guide

ii RSBatch Equipment Editor User s Guide Allen-Bradley PLCs Contacting Rockwell Software Technical Support Telephone 440-646-7800 Technical Support Fax 440-646-7801 World Wide Web www.software.rockwell.com Copyright Notice 1998 Rockwell Software

More information

RSNetWorx RSNETWORX FOR ETHERNET/IP GETTING RESULTS GUIDE. PUBLICATION ENET-GR001D-EN-E July 2008 Supersedes Publication ENET-GR001C-EN-E

RSNetWorx RSNETWORX FOR ETHERNET/IP GETTING RESULTS GUIDE. PUBLICATION ENET-GR001D-EN-E July 2008 Supersedes Publication ENET-GR001C-EN-E RSNetWorx RSNETWORX FOR ETHERNET/IP GETTING RESULTS GUIDE PUBLICATION ENET-GR001D-EN-E July 2008 Supersedes Publication ENET-GR001C-EN-E Contact Rockwell Customer Support Telephone 1.440.646.3434 Online

More information

Installation Instructions. FactoryTalk View Site Edition Installation Guide

Installation Instructions. FactoryTalk View Site Edition Installation Guide Installation Instructions FactoryTalk View Site Edition Installation Guide Important user information Read this document and the documents listed in the additional resources section about installation,

More information

FactoryTalk View Site Edition. Installation Guide

FactoryTalk View Site Edition. Installation Guide FactoryTalk View Site Edition Installation Guide Important user information Read this document and the documents listed in the additional resources section about installation, configuration, and operation

More information

WizReport XL Server Guide

WizReport XL Server Guide Axeda Supervisor The complete Internet-based solution for control and information WizReport XL Server Guide August 2005 Server Guide Version 6.00 The new bridge between your data and your worksheet. Information

More information

ODBC Client Driver PTC Inc. All Rights Reserved.

ODBC Client Driver PTC Inc. All Rights Reserved. 2017 PTC Inc. All Rights Reserved. 2 Table of Contents 1 Table of Contents 2 4 Overview 4 External Dependencies 4 Setup 5 Channel Properties General 5 Channel Properties Write Optimizations 6 Channel Properties

More information

TopView SQL Configuration

TopView SQL Configuration TopView SQL Configuration Copyright 2013 EXELE Information Systems, Inc. EXELE Information Systems (585) 385-9740 Web: http://www.exele.com Support: support@exele.com Sales: sales@exele.com Table of Contents

More information

Administrator s Guide. Doc ID BZWARE-IN001B-EN-P

Administrator s Guide. Doc ID BZWARE-IN001B-EN-P Administrator s Guide Doc ID BZWARE-IN001B-EN-P Contacting Technical Support Telephone 1-440-646-5800 Rockwell Software Technical Support Fax 1-440-646-5801 World Wide Web www.software.rockwell.com Copyright

More information

Eclipse Forms. Release 8.7.2

Eclipse Forms. Release 8.7.2 Eclipse Forms Release 8.7.2 Legal Notices 2011 Epicor Software Corporation. All rights reserved. Unauthorized reproduction is a violation of applicable laws. Epicor and the Epicor logo are registered trademarks

More information

RSView 32 Setup. Enabling the OPC Server By default, the RSView32 OPC Server is not enabled.

RSView 32 Setup. Enabling the OPC Server By default, the RSView32 OPC Server is not enabled. RSView 32 Setup Reporting from RSView 32 XLReporter generates Excel based reports from Rockwell Automation RSView 32 using current process values in the tag database, historical logs and alarm archives.

More information

Using OPC90 with OSIsoft PI

Using OPC90 with OSIsoft PI Using OPC90 with OSIsoft PI Using OPC90 with OSIsoft PI requires the following components: 1. A PI server. This may be a PI 2.x Server on VAX/VMS or a PI 3.x Enterprise Server on Windows or UNIX. 2. The

More information

Allen-Bradley Drives ADMINISTRATION GUIDE. Rockwell Automation Publication BZWARE-IN001N-EN-P-August 2017

Allen-Bradley Drives ADMINISTRATION GUIDE. Rockwell Automation Publication BZWARE-IN001N-EN-P-August 2017 ADMINISTRATION GUIDE Rockwell Automation Publication BZWARE-IN001N-EN-P-August 2017 Supersedes Publication BZWARE-IN001M-EN-P-June 2014 Allen-Bradley Drives Preface Copyright notice End User License Agreement

More information

PI OPC DA Server User Guide

PI OPC DA Server User Guide PI OPC DA Server 2017 User Guide OSIsoft, LLC 1600 Alvarado Street San Leandro, CA 94577 USA Tel: (01) 510-297-5800 Fax: (01) 510-357-8136 Web: http://www.osisoft.com PI OPC DA Server 2017 User Guide 1992-2017

More information

PI DataLink User Guide

PI DataLink User Guide PI DataLink 2016 User Guide OSIsoft, LLC 777 Davis St., Suite 250 San Leandro, CA 94577 USA Tel: (01) 510-297-5800 Fax: (01) 510-357-8136 Web: http://www.osisoft.com PI DataLink 2016 User Guide 1992-2016

More information

FactoryTalk Historian SE Setup

FactoryTalk Historian SE Setup FactoryTalk Historian SE Setup FactoryTalk Historian SE Reporting XLReporter generates Excel based reports from Rockwell Automation FactoryTalk Historian SE using historical logged data. The purpose of

More information

DeltaV Continuous Historian

DeltaV Continuous Historian Frequently Asked Questions Data Analysis Integrated Configuration Scalable Flexible Architecture Contents 1. Introduction 1.1. What is the DeltaV Continuous Historian? 5 1.2. What features are available

More information

Microsoft Excel 2010 Basics

Microsoft Excel 2010 Basics Microsoft Excel 2010 Basics Starting Word 2010 with XP: Click the Start Button, All Programs, Microsoft Office, Microsoft Excel 2010 Starting Word 2010 with 07: Click the Microsoft Office Button with the

More information

Oracle Cloud Using the Evernote Adapter. Release 17.3

Oracle Cloud Using the Evernote Adapter. Release 17.3 Oracle Cloud Using the Evernote Adapter Release 17.3 E69234-07 September 2017 Oracle Cloud Using the Evernote Adapter, Release 17.3 E69234-07 Copyright 2016, 2017, Oracle and/or its affiliates. All rights

More information

ER/Studio Enterprise Portal User Guide

ER/Studio Enterprise Portal User Guide ER/Studio Enterprise Portal 1.0.3 User Guide Copyright 1994-2009 Embarcadero Technologies, Inc. Embarcadero Technologies, Inc. 100 California Street, 12th Floor San Francisco, CA 94111 U.S.A. All rights

More information

PI Connector for Ping 1.0. User Guide

PI Connector for Ping 1.0. User Guide PI Connector for Ping 1.0 User Guide OSIsoft, LLC 777 Davis St., Suite 250 San Leandro, CA 94577 USA Tel: (01) 510-297-5800 Fax: (01) 510-357-8136 Web: http://www.osisoft.com PI Connector for Ping 1.0

More information

FactoryTalk Security. System Configuration Guide

FactoryTalk Security. System Configuration Guide FactoryTalk Security System Configuration Guide Table of contents Preface About this publication... 11 Required software... 12 Required hardware... 13 Additional resources... 14 Legal Notices... 15 Chapter

More information

GUARD1 PLUS Documentation. Version TimeKeeping Systems, Inc. GUARD1 PLUS and THE PIPE are registered trademarks

GUARD1 PLUS Documentation. Version TimeKeeping Systems, Inc. GUARD1 PLUS and THE PIPE are registered trademarks GUARD1 PLUS Documentation Version 3.02 2000-2005 TimeKeeping Systems, Inc. GUARD1 PLUS and THE PIPE are registered trademarks i of TimeKeeping Systems, Inc. Table of Contents Welcome to Guard1 Plus...

More information

Exhibitor Software User s Manual. Exhibitor Software V

Exhibitor Software User s Manual. Exhibitor Software V Exhibitor Software User s Manual Exhibitor Software V1.0.1 090908 1 Contents 1. Exhibitor Software 2. Installation 3. Using Exhibitor Program 3.1 Starting the Program 3.2 Logging in to the Program 3.3

More information

Excel4apps Reports Distribution Manager User Guide (SAP) 2013 Excel4apps

Excel4apps Reports Distribution Manager User Guide (SAP) 2013 Excel4apps Excel4apps Reports Distribution Manager User Guide (SAP) 2013 Excel4apps Table of Contents 1 System Requirements... 4 2 Installation and Overview... 4 2.1 Definitions... 4 2.1.1 Report Distribution Manager...

More information

CONFIGURATION GUIDE. Catalog Number 1756-HIST2G. Rockwell Automation Publication 1756-UM106D-EN-E-January 2018

CONFIGURATION GUIDE. Catalog Number 1756-HIST2G. Rockwell Automation Publication 1756-UM106D-EN-E-January 2018 CONFIGURATION GUIDE Catalog Number 1756-HIST2G Rockwell Automation Publication 1756-UM106D-EN-E-January 2018 Supersedes Publication 1756-UM106C-EN-E-June 2017 Preface Copyright notice End User License

More information

Getting Results Guide. Doc ID EMULAT-GR002A-EN-P

Getting Results Guide. Doc ID EMULAT-GR002A-EN-P Getting Results Guide Doc ID EMULAT-GR002A-EN-P Contacting Technical Support Telephone 1-440-646-7800 Rockwell Software Technical Support Fax 1-440-646-7801 World Wide Web www.software.rockwell.com Copyright

More information

RSPower RSPOWER AND RSPOWERPLUS GETTING RESULTS GUIDE. PUBLICATION RSPWR-GR002D-EN-P May 2007 Supersedes Publication RSPWR-GR002C-EN-P

RSPower RSPOWER AND RSPOWERPLUS GETTING RESULTS GUIDE. PUBLICATION RSPWR-GR002D-EN-P May 2007 Supersedes Publication RSPWR-GR002C-EN-P RSPower RSPOWER AND RSPOWERPLUS GETTING RESULTS GUIDE PUBLICATION RSPWR-GR002D-EN-P May 2007 Supersedes Publication RSPWR-GR002C-EN-P Contact Rockwell Customer Support Telephone 1.440.646.3434 Online Support

More information

Agilent OpenLAB ECM Intelligent Reporter

Agilent OpenLAB ECM Intelligent Reporter Agilent OpenLAB ECM Intelligent Reporter Installation and Configuration Guide Agilent Technologies Notices Agilent Technologies, Inc. 2007-2016 No part of this manual may be reproduced in any form or by

More information

PanelView Plus and Text Historian Guide

PanelView Plus and Text Historian Guide PanelView Plus and Text Historian Guide Version 12.4 SyTech, Inc. The Complete Reporting Solution Information in this document is subject to change without notice. SyTech, Inc. assumes no responsibility

More information

Using. Zacks Link. Version

Using. Zacks Link. Version Using Zacks Link Version 4.0.305 Zacks Investment Research, Inc. 2006 Last Updated: 6/05/2006 Contents Overview 1 What is Zacks Link...1 How Zacks Link Works...1 Zacks Link Version 4.0.305...1 System

More information

Nimsoft Monitor. exchange_response Guide. v2.5 series

Nimsoft Monitor. exchange_response Guide. v2.5 series Nimsoft Monitor exchange_response Guide v2.5 series Legal Notices Copyright 2014, CA. All rights reserved. Warranty The material contained in this document is provided "as is," and is subject to being

More information

1. Introduction Features Operating Environment Machine Data...6

1. Introduction Features Operating Environment Machine Data...6 1 Table of Contents 1. Introduction...3 1.1 Features... 4 1.2 Operating Environment... 5 2. Machine Data...6 2.1 Fetching New Machines... 8 2.2 Adding New Machines... 10 2.3 Updating Scan Data... 12 2.4

More information

PI DataLink User Guide

PI DataLink User Guide PI DataLink 2015 User Guide OSIsoft, LLC 777 Davis St., Suite 250 San Leandro, CA 94577 USA Tel: (01) 510-297-5800 Fax: (01) 510-357-8136 Web: http://www.osisoft.com PI DataLink 2015 User Guide 1992-2015

More information

Doc. Version 1.0 Updated:

Doc. Version 1.0 Updated: OneStop Reporting Report Composer 3.5 User Guide Doc. Version 1.0 Updated: 2012-01-02 Table of Contents Introduction... 2 Who should read this manual... 2 What s included in this manual... 2 Symbols and

More information

Connected Components Workbench Release Notes

Connected Components Workbench Release Notes Connected Components Workbench Release Notes January 2017 These release notes apply to Connected Components Workbench version 10.01 software. Use Connected Components Workbench software to configure controllers

More information

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17 User Manual Navigator Software Monarch Instrument Rev 0.98 May 2006 Page 1 of 17 Contents 1. NAVIGATOR SOFTWARE 2. INSTALLATION 3. USING NAVIGATOR SOFTWARE 3.1 STARTING THE PROGRAM 3.2 SYSTEM SET UP 3.3

More information

GE Fanuc Automation. CIMPLICITY HMI Plant Edition. Trend and XY Chart. CIMPLICITY Monitoring and Control Products.

GE Fanuc Automation. CIMPLICITY HMI Plant Edition. Trend and XY Chart. CIMPLICITY Monitoring and Control Products. GE Fanuc Automation CIMPLICITY Monitoring and Control Products CIMPLICITY HMI Plant Edition Trend and XY Chart Operation Manual GFK-1260H July 2001 Following is a list of documentation icons: GFL-005 Warning

More information

APM Import Tool. Product Guide

APM Import Tool. Product Guide APM Import Tool Product Guide This documentation and any related computer software help programs (hereinafter referred to as the Documentation ) is for the end user s informational purposes only and is

More information

Excel's functionality falls into three different categories:

Excel's functionality falls into three different categories: Excel Data Analysis Options Excel's functionality falls into three different categories: entering data, analyzing data, and displaying the results. Understanding and accurately performing these functions

More information

RSView SE V4.0 (CPR7+) Server Redundancy Guidelines

RSView SE V4.0 (CPR7+) Server Redundancy Guidelines RSView SE V4.0 (CPR7+) Server Redundancy Guidelines This page left intentionally blank. RSView SE 4.0 (CPR7+) Server Redundancy Guidelines.doc 2/14/2007 Page 2 of 17 Table of Contents Introduction...4

More information

Beijer Electronics Data Collector. Manual. English MAEN826B,

Beijer Electronics Data Collector. Manual. English MAEN826B, MAEN826B, 2009-10 Beijer Electronics Data Collector Manual English Foreword Beijer Electronics Data Collector Manual Foreword Beijer Electronics Data Collector is used to save trend and alarm data logged

More information

Oracle SQL. murach s. and PL/SQL TRAINING & REFERENCE. (Chapter 2)

Oracle SQL. murach s. and PL/SQL TRAINING & REFERENCE. (Chapter 2) TRAINING & REFERENCE murach s Oracle SQL and PL/SQL (Chapter 2) works with all versions through 11g Thanks for reviewing this chapter from Murach s Oracle SQL and PL/SQL. To see the expanded table of contents

More information

Load Bulletin ADP, Inc. Dealer Services 5607 New King Street Troy, MI Executive Assistant. Loading the 8.0 Client Media

Load Bulletin ADP, Inc. Dealer Services 5607 New King Street Troy, MI Executive Assistant. Loading the 8.0 Client Media Load Bulletin ADP, Inc. Dealer Services 5607 New King Street Troy, MI 48098 Make sure the product code(s) on the media label include this number: 8.0 Executive Assistant Loading the 8.0 Client Media This

More information

AppsAudit. User s Guide. Software Version 7.0

AppsAudit. User s Guide. Software Version 7.0 AppsAudit User s Guide Software Version 7.0 2005 Logical Apps All rights reserved. Printed in USA. Restricted Rights Legend This software and associated documentation contain proprietary information of

More information

Sedao Ltd. QuickChange PROject. User Manual for QuickChange PROject version 2.1.5

Sedao Ltd. QuickChange PROject. User Manual for QuickChange PROject version 2.1.5 Sedao Ltd QuickChange PROject User Manual for QuickChange PROject version 2.1.5 Contents What is QuickChange PROject?... 2 Simple Artwork Creation... 5 Creating a project... 7 QuickChange PROject Template

More information

DataLogger PTC Inc. All Rights Reserved.

DataLogger PTC Inc. All Rights Reserved. 2018 PTC Inc. All Rights Reserved. 2 Table of Contents 1 Table of Contents 2 5 Overview 6 Initial Setup Considerations 6 System Requirements 7 External Dependencies 7 Supported Data Types 8 SQL Authentication

More information

Dream Report Version 4.6 Release 4

Dream Report Version 4.6 Release 4 Release Notes Dream Report Version 4.6 Release 4 User Friendly Programming-Free Reporting for Automation Version: 4.6 Release 4 1 P a g e Copyright (R) Ocean Data Systems Ltd., All rights reserved R e

More information

Writer Guide. Chapter 15 Using Forms in Writer

Writer Guide. Chapter 15 Using Forms in Writer Writer Guide Chapter 15 Using Forms in Writer Copyright This document is Copyright 2005 2010 by its contributors as listed below. You may distribute it and/or modify it under the terms of either the GNU

More information

Nimsoft Monitor. websphere Guide. v1.5 series

Nimsoft Monitor. websphere Guide. v1.5 series Nimsoft Monitor websphere Guide v1.5 series Legal Notices Copyright 2012, Nimsoft Corporation Warranty The material contained in this document is provided "as is," and is subject to being changed, without

More information

Oracle Cloud Using the MailChimp Adapter. Release 17.3

Oracle Cloud Using the MailChimp Adapter. Release 17.3 Oracle Cloud Using the MailChimp Adapter Release 17.3 E70293-07 September 2017 Oracle Cloud Using the MailChimp Adapter, Release 17.3 E70293-07 Copyright 2016, 2017, Oracle and/or its affiliates. All rights

More information

SVA NMP Monitor for Unicenter TNG on Windows NT/2000

SVA NMP Monitor for Unicenter TNG on Windows NT/2000 SVA NMP Monitor for Unicenter TNG on Windows NT/2000 Installation Guide Version 3.1.1 First Edition Proprietary Information Statement The information in this document is confidential and proprietary to

More information

Eaton Corporation Cutler-Hammer Business Unit 811 Green Crest Drive Columbus, OH PanelMate PC DDE Connectivity Communication Driver Manual

Eaton Corporation Cutler-Hammer Business Unit 811 Green Crest Drive Columbus, OH PanelMate PC DDE Connectivity Communication Driver Manual Eaton Corporation Cutler-Hammer Business Unit 811 Green Crest Drive Columbus, OH 43081 PanelMate PC DDE Connectivity Communication Driver Manual Preface Information in this manual is subject to change

More information

Doc. Version 1.0 Updated:

Doc. Version 1.0 Updated: OneStop Reporting Report Designer/Player 3.5 User Guide Doc. Version 1.0 Updated: 2012-01-02 Table of Contents Introduction... 3 Who should read this manual... 3 What s included in this manual... 3 Symbols

More information

SAS Web Report Studio 3.1

SAS Web Report Studio 3.1 SAS Web Report Studio 3.1 User s Guide SAS Documentation The correct bibliographic citation for this manual is as follows: SAS Institute Inc. 2006. SAS Web Report Studio 3.1: User s Guide. Cary, NC: SAS

More information

DS800 Development Suite Quick Start Guide for the FloBoss 107

DS800 Development Suite Quick Start Guide for the FloBoss 107 Form A6267 Part Number D301597X012 January 2009 DS800 Development Suite Quick Start Guide for the FloBoss 107 Version 1.0 Remote Automation Solutions Revision Tracking Sheet January 2009 This manual may

More information

Oracle Cloud Using the Oracle Responsys Adapter. Release 17.3

Oracle Cloud Using the Oracle Responsys Adapter. Release 17.3 Oracle Cloud Using the Oracle Responsys Adapter Release 17.3 E70393-06 September 2017 Oracle Cloud Using the Oracle Responsys Adapter, Release 17.3 E70393-06 Copyright 2016, 2017, Oracle and/or its affiliates.

More information

HP OpenView Service Desk

HP OpenView Service Desk HP OpenView Service Desk OpenView Operations Integration Administrator s Guide Software Version: 5.10 For the Windows and UNIX Operating Systems Manufacturing Part Number: None Document Release Date: August

More information

USER GUIDE. Rockwell Automation Publication RPTEXP-UM001I-EN-P-August 2017

USER GUIDE. Rockwell Automation Publication RPTEXP-UM001I-EN-P-August 2017 USER GUIDE Rockwell Automation Publication RPTEXP-UM001I-EN-P-August 2017 Supersedes Publication RPTEXP-UM001H-EN-P-June 2014 Preface Copyright notice End User License Agreement (EULA) Other licenses Trademark

More information

AppsAudit. User s Guide. Software Version 6.5.6

AppsAudit. User s Guide. Software Version 6.5.6 AppsAudit User s Guide Software Version 6.5.6 2006 LogicalApps All rights reserved. Printed in USA. Restricted Rights Legend This software and associated documentation contain proprietary information of

More information

Network Management Utility

Network Management Utility 4343-7705-02 Network Management Utility Foreword Welcome Network Management Utility is utility software that provides central control over printers, copiers, and other devices on a network. With Network

More information

Adobe Marketing Cloud Report Builder

Adobe Marketing Cloud Report Builder Adobe Marketing Cloud Report Builder Contents Adobe Report Builder Help...6 What's New in Report Builder...7 Report Builder 5.6...7 Report Builder 5.5...7 Report Builder 5.4...7 Report Builder 5.3...8

More information

Excel 2010: Getting Started with Excel

Excel 2010: Getting Started with Excel Excel 2010: Getting Started with Excel Excel 2010 Getting Started with Excel Introduction Page 1 Excel is a spreadsheet program that allows you to store, organize, and analyze information. In this lesson,

More information

Microsoft Office 2016 Mail Merge

Microsoft Office 2016 Mail Merge Microsoft Office 2016 Mail Merge Mail Merge Components In order to understand how mail merge works you need to examine the elements involved in the process. In any mail merge, you'll deal with three different

More information

System Management Guide Version 7.52

System Management Guide Version 7.52 Sage 500 Budgeting and Planning 2013 System Management Guide Version 7.52 Copyright Trademarks Program copyright 1995-2013 Sage Software, Inc. This work and the computer programs to which it relates are

More information

DOWNLOAD PDF VBA MACRO TO PRINT MULTIPLE EXCEL SHEETS TO ONE

DOWNLOAD PDF VBA MACRO TO PRINT MULTIPLE EXCEL SHEETS TO ONE Chapter 1 : Print Multiple Sheets Macro to print multiple sheets I have a spreadsheet set up with multiple worksheets. I have one worksheet (Form tab) created that will pull data from the other sheets

More information

Oracle Cloud Using the Eventbrite Adapter. Release 17.3

Oracle Cloud Using the Eventbrite Adapter. Release 17.3 Oracle Cloud Using the Eventbrite Adapter Release 17.3 E69235-08 September 2017 Oracle Cloud Using the Eventbrite Adapter, Release 17.3 E69235-08 Copyright 2016, 2017, Oracle and/or its affiliates. All

More information

Oracle Cloud Using the Oracle Advanced Queuing (AQ) Adapter. Release 17.3

Oracle Cloud Using the Oracle Advanced Queuing (AQ) Adapter. Release 17.3 Oracle Cloud Using the Oracle Advanced Queuing (AQ) Adapter Release 17.3 E76448-04 September 2017 Oracle Cloud Using the Oracle Advanced Queuing (AQ) Adapter, Release 17.3 E76448-04 Copyright 2016, 2017,

More information

Some useful shortcut keys applicable for both Excel and Word (16 to 19 is only for Excel): Sr.No. Shortcut Keys Description

Some useful shortcut keys applicable for both Excel and Word (16 to 19 is only for Excel): Sr.No. Shortcut Keys Description Some useful shortcut keys applicable for both Excel and Word (16 to 19 is only for Excel): Sr.No. Shortcut Keys Description 1 Ctrl + C Copy the selected data 2 Ctrl + X Cut the selected data 3 Ctrl + V

More information

Getting Results. RSLinx Classic Getting Results Guide

Getting Results. RSLinx Classic Getting Results Guide Getting Results RSLinx Classic Getting Results Guide Important user information Read this document and the documents listed in the additional resources section about installation, configuration, and operation

More information

1. ECI Hosted Clients Installing Release 6.3 for the First Time (ECI Hosted) Upgrading to Release 6.3SP2 (ECI Hosted)

1. ECI Hosted Clients Installing Release 6.3 for the First Time (ECI Hosted) Upgrading to Release 6.3SP2 (ECI Hosted) 1. ECI Hosted Clients........................................................................................... 2 1.1 Installing Release 6.3 for the First Time (ECI Hosted)...........................................................

More information

Excel4apps Reports Wand User Guide (SAP) 2013 Excel4apps

Excel4apps Reports Wand User Guide (SAP) 2013 Excel4apps Excel4apps Reports Wand User Guide (SAP) 2013 Excel4apps Table of Contents 1 QuickStart Guide... 4 2 System Requirements... 5 3 Authorizations... 5 4 Logging On... 5 5 The Reports Wand Toolbar A Brief

More information

ZENworks Reporting System Reference. January 2017

ZENworks Reporting System Reference. January 2017 ZENworks Reporting System Reference January 2017 Legal Notices For information about legal notices, trademarks, disclaimers, warranties, export and other use restrictions, U.S. Government rights, patent

More information

Nimsoft Monitor Server

Nimsoft Monitor Server Nimsoft Monitor Server Configuration Guide v6.00 Document Revision History Version Date Changes 1.0 10/20/2011 Initial version of Nimsoft Server Configuration Guide, containing configuration and usage

More information

Excel 2010 Formulas Don't Update Automatically

Excel 2010 Formulas Don't Update Automatically Excel 2010 Formulas Don't Update Automatically Home20132010Other VersionsLibraryForumsGallery Ask a question How can I make the formula result to update automatically when I open it after each update on

More information

Oracle Communications Performance Intelligence Center

Oracle Communications Performance Intelligence Center Oracle Communications Performance Intelligence Center Browser Export Scheduler Guide Release 10.2 E66874 Revision 1 February 2016 i Oracle Communications Performance Intelligence Center Browser Export

More information

DocAve for Salesforce 2.1

DocAve for Salesforce 2.1 DocAve for Salesforce 2.1 This document is intended for anyone wishing to familiarize themselves with the user interface and basic functionality of AvePoint s DocAve for Salesforce tool. System Requirements

More information

1. AUTO CORRECT. To auto correct a text in MS Word the text manipulation includes following step.

1. AUTO CORRECT. To auto correct a text in MS Word the text manipulation includes following step. 1. AUTO CORRECT - To auto correct a text in MS Word the text manipulation includes following step. - STEP 1: Click on office button STEP 2:- Select the word option button in the list. STEP 3:- In the word

More information

CA Output Management Web Viewer

CA Output Management Web Viewer CA Output Management Web Viewer User Guide Release 12.1.00 This Documentation, which includes embedded help systems and electronically distributed materials, (hereinafter referred to as the Documentation

More information

PI Interface for RDBMS User Guide

PI Interface for RDBMS User Guide PI Interface for RDBMS 3.22 User Guide OSIsoft, LLC 777 Davis St., Suite 250 San Leandro, CA 94577 USA Tel: (01) 510-297-5800 Fax: (01) 510-357-8136 Web: http://www.osisoft.com PI Interface for RDBMS 3.22

More information

Following are the system requirements for running e-form RS:

Following are the system requirements for running e-form RS: When you purchase e-form RS, you will receive an e-mail message with your account number and password. As the system administrator, you should be the first person to sign on so you can set up accounts,

More information

-Table of Contents- 1. Overview Installation and removal Operation Main menu Trend graph... 13

-Table of Contents- 1. Overview Installation and removal Operation Main menu Trend graph... 13 Thank you for buying Data Analysis Software. In order to use this software correctly and safely and to prevent trouble, please read this manual carefully. Notice 1. No part of this manual can be reproduced

More information

MS Office for Engineers

MS Office for Engineers MS Office for Engineers Lesson 4 Excel 2 Pre-reqs/Technical Skills Basic knowledge of Excel Completion of Excel 1 tutorial Basic computer use Expectations Read lesson material Implement steps in software

More information

Doc. Version 1.0 Updated:

Doc. Version 1.0 Updated: OneStop Reporting Report Publisher 3.5 User Guide Doc. Version 1.0 Updated: 2012-01-02 Table of Contents Introduction... 3 Who should read this manual... 3 What s included in this manual... 3 Symbols and

More information

System Monitoring Plug-in Installation Guide for Microsoft Internet Information Services Release 4 ( ) Versions Supported

System Monitoring Plug-in Installation Guide for Microsoft Internet Information Services Release 4 ( ) Versions Supported Oracle Enterprise Manager System Monitoring Plug-in Installation Guide for Microsoft Internet Information Services Release 4 (2.1.2.1.0) B28047-03 April 2007 This document provides a brief description

More information

Top Producer for Palm Handhelds

Top Producer for Palm Handhelds Top Producer for Palm Handhelds Quick Setup Top Producer Systems Phone number: 1-800-830-8300 Email: support@topproducer.com www.topproducer.com Fax: 604.270.6365 Top Producer for Palm handhelds Quick

More information