Grille. Min. - max. dimensions

Size: px
Start display at page:

Download "Grille. Min. - max. dimensions"

Transcription

1 Min. - max. dimensions 1 / / Description is a supply grille made from aluminum with curved adjustable blades, oriented 1-way or 2-way horizontal or vertical both for wall and ceiling installation. The grille is available with several mounting options and can be delivered with mounting frame, opposed blade damper and plenum box accessories. Order code Product 1 a b c ddd x eee ffff Type Frame 1 - mm frame Grid 1 - orizontal curved blades way 2 - Vertical curved blades way - orizontal curved blades ways - Vertical curved blades ways Installation - Not prepared C Clips CM Clips + mounting frame V Visible screw holes VM Visible screw holes + mounting frame idden screw installation M idden screws + mounting frame Accessories - No accessories D Opposed blade damper Size : 0-00 mm : 0 - mm Only 1 / : 0 - mm Only 2 / s standard finish: - Anodized aluminium 90 RA 90, gloss RA 900, gloss 0 xxxx On request, other RA colour Example 1: 1-CM-D Example 2: Standard grilles are availablein steps of 50 mm within the above min. and max. sizes. Customized sizes available on request. indqst Use the advanced indab web tool indqst to calculate the full range of grilles and to find the suitable grille type and dimension for all applications. Product selection, room dimensioning and documentation search are easy available directly on web and mobile devices. Find this and much more on Maintenance The grille should be removed to gain access to the plenum box or duct. The external parts should be wiped with a damp cloth. Accessories Plenum box: Mounting frame: Volume regulator: Materials and finish frame and blades: Mounting frame: Opposed blade damper: s standard finish: - Aluminium anodized - RA 90, gloss 0 - RA 900, gloss 0 PBA MFA DGA Anodized aluminium Galvanized steel Galvanized steel The grille is available in other colours. Please contact indab's sales department for further information. We reserve the right to make changes without prior notice 1

2 Frame and grid 1 mm frame with horizontal curved blades - 1 way Installation - Not prepared +2 1, mm frame with Vertical curved blades way C - Clips CM - Clips + mounting frame ,5-0 x C +5 x +5 CM mm frame with horizontal curved blades - 2 ways V* - Visible screw holes VM* - Visible screw holes + mounting frame , x -8 V * Screws are not included. +5 x +5 VM - idden screws mm frame with vertical curved blades - 2 ways +2 1, M x 0-5 x x +5 2 We reserve the right to make changes without prior notice

3 Accessories - No damper D - Opposed blade damper DGA x with installation type C, CM, V and VM. A full length click-on DGA-damper is available. x with installation type or M has a shortend DGA damper option due to the hidden screw installation type. The damper is mounted from factory and is not detachable. x = 51 mm Available DGA sizes Single piece Multiple pieces x x x x x 00 x x x 00 Not available sizes 00 x We reserve the right to make changes without prior notice

4 Free area 1 / 2 Curved blade grille 1 - way A k (m 2 ) / ,00 0,008 0,0 0,011 0,01 0,0 0,01 0,018 0,0 0,02 0,027 0,00 0,0 0 0,0 0,01 0,0 0,018 0,021 0,02 0,02 0,029 0,02 0,07 0,02 0,08 0,05 0 0,01 0,017 0,021 0,0 0,028 0,02 0,0 0,00 0,0 0,051 0,058 0,0 0,07 0 0,017 0,022 0,027 0,0 0,0 0,01 0,0 0,050 0,055 0,0 0,07 0,08 0, ,021 0,027 0,0 0,08 0,0 0,050 0,055 0,01 0,07 0,078 0,090 0,1 0, ,0 0,02 0,08 0,05 0,052 0,058 0,05 0,072 0,079 0,092 0,5 0,119 0, ,029 0,0 0,0 0,052 0,059 0,07 0,075 0,08 0,090 0, 0,121 0,17 0,2 50 0,02 0,01 0,050 0,058 0,07 0,07 0,085 0,09 0,2 0,119 0,17 0, 0, ,0 0,0 0,05 0,05 0,075 0,085 0,09 0, 0,11 0,1 0, 0,172 0, ,00 0,051 0,01 0,072 0,08 0,09 0, 0,1 0,12 0,17 0,18 0,190 0, ,0 0,055 0,07 0,079 0,090 0,2 0,11 0,12 0,17 0,11 0,18 0,8 0, ,051 0,05 0,079 0,092 0, 0,1 0,1 0,17 0,11 0,188 0,21 0,2 0, ,059 0,07 0,090 0, 0,121 0,17 0, 0,19 0,18 0,21 0,27 0,279 0, ,0 0,08 0,2 0,119 0,17 0,5 0,172 0,190 0,8 0,2 0,279 0, 0,9 00 0,07 0,09 0,11 0,1 0,2 0,172 0,192 0,212 0,2 0,271 0,0 0,50 0,89 / Curved blade grille 2 - ways A k (m 2 ) / ,005 0,00 0,008 0,0 0,012 0,01 0,0 0,017 0,018 0,022 0,0 0,029 0,02 0 0,007 0,0 0,01 0,01 0,018 0,021 0,02 0,02 0,029 0,05 0,00 0,05 0, ,0 0,01 0,018 0,021 0,0 0,029 0,02 0,0 0,00 0,07 0,055 0,02 0, ,01 0,018 0,022 0,027 0,02 0,0 0,01 0,0 0,051 0,00 0,09 0,079 0, ,01 0,021 0,027 0,0 0,09 0,0 0,050 0,05 0,01 0,07 0,08 0,09 0,7 50 0,018 0,0 0,02 0,09 0,05 0,052 0,059 0,05 0,072 0,08 0,099 0,112 0, ,021 0,029 0,07 0,0 0,052 0,00 0,07 0,075 0,08 0,098 0,11 0,129 0, ,02 0,0 0,01 0,050 0,059 0,07 0,07 0,085 0,09 0,111 0,128 0,1 0, ,027 0,0 0,0 0,05 0,0 0,075 0,085 0,095 0, 0,12 0,1 0,1 0, ,029 0,00 0,051 0,02 0,072 0,08 0,09 0, 0,1 0,17 0,8 0,179 0,1 00 0,02 0,0 0,05 0,07 0,079 0,091 0,2 0,11 0,12 0,19 0,17 0,19 0, ,08 0,051 0,05 0,079 0,09 0, 0,1 0,1 0,17 0,175 0,2 0,20 0, ,0 0,059 0,075 0,090 0, 0,122 0,17 0, 0,19 0,0 0,22 0,2 0, ,09 0,0 0,08 0,2 0,1 0,17 0,5 0,17 0,190 0,22 0,21 0,297 0,2 00 0,05 0,07 0,09 0,11 0,1 0, 0,172 0,192 0,212 0,1 0,291 0,0 0,70 We reserve the right to make changes without prior notice

5 Quick selection, Supply air, 1 / 2 size [mm] =0 =0 =0 =00 Air flow rate m³/h A k [m²] l/s (1) (22) () (5) (9) (8) (97) (111) (19) (17) (19) (222) (0) (278) (7) (17) (500) (55) WA [db(a)] x0 V k [m/s] 2,, 5, (0,00) Δp t [Pa] 9 0,2 [m] 1, 2,5,7 WA [db(a)] < x0 V k [m/s] 1,5 2,,5 5,9 (0,01) Δp t [Pa] ,2 [m] 1, 2 5 WA [db(a)] < x0 V k [m/s] 1,7 2,, 5, (0,01) Δp t [Pa] 2 1 0,2 [m] 1,7 2,, 5,2 WA [db(a)] < x0 V k [m/s] 1, 2,,2 5,1 5,9 (0,01) Δp t [Pa] ,2 [m] 1, 2,,8,7 5,,5 WA [db(a)] < x0 V k [m/s] 1,7 2,8,5,2,9 5, (0,02) Δp t [Pa] ,2 [m] 2,1,5,2 5,1 5,9,7 WA [db(a)] x0 V k [m/s] 2,1 2,,1,,2 5,2 (0,027) Δp t [Pa] ,2 [m],7, 5,1 5,8 7,2 WA [db(a)] < x0 V k [m/s] 1, 2,2,7,5 5, (0,0) Δp t [Pa] ,2 [m] 1, 2,,9,8 5,8 WA [db(a)] < x0 V k [m/s] 1, 2,7,,7 5, (0,021) Δp t [Pa] ,2 [m] 2,,2 5 5,8, WA [db(a)] x0 V k [m/s] 2,1 2,,2,7, 5, (0,02) Δp t [Pa] ,2 [m],7, 5,1 5,8 7, WA [db(a)] < x0 V k [m/s] 1,8 2,2 2,,1,5, 5,,2 (0,02) Δp t [Pa] ,2 [m] 2,7,,7 5,, 7,9 9,1 WA [db(a)] < < x0 V k [m/s] 1, 1, 2 2, 2,,,9, 5,2 5,9 (0,02) Δp t [Pa] ,2 [m] 2, 2,9,,5 5,,7 7,8 8,9 9,9 WA [db(a)] x0 V k [m/s] 2 2, 2,9,,9,9 5,9 (0,028) Δp t [Pa] ,2 [m] 2,9,5,2,9 5,,9 8, WA [db(a)] < x0 V k [m/s] 1, 1,9 2, 2,7,1,9,7 5,,2 (0,0) Δp t [Pa] ,2 [m] 2,,1,8, 5,2 7, 8,5 9,7 WA [db(a)] < < x0 V k [m/s] 1, 1, 1,9 2,2 2,,2,9,5 5,1 5,8 (0,0) Δp t [Pa] ,2 [m] 2, 2,8,,5 5,,7 7,7 8,8 9,8 WA [db(a)] < < < x0 V k [m/s] 1, 1,7 1,9 2, 2,9,,8,,8 (0,058) Δp t [Pa] ,2 [m] 2,9,,8,8 5,7,5 7,5 8, 9, 11,5 WA [db(a)] < < x00 V k [m/s] 1,5 1,8 2 2,5,5,5 5, (0,055) Δp t [Pa] ,2 [m],5,9,9 5,8,7 7,7 8, 9,5 11,8 WA [db(a)] < < x00 V k [m/s] 1,5 1,7 2,1 2,5 2,9,,7,2 5,2,2 (0,07) Δp t [Pa] ,2 [m],1,5, 5,2,1,9 7,7 8,, 12, WA [db(a)] < < x00 V k [m/s] 1, 1,9 2,2 2,5 2,8,1,9,7 5,,2 (0,09) Δp t [Pa] ,2 [m],7, 5,1 5,8,5 7,2 8,9, 12, 1 WA < 0 0 WA < 0 0 WA < 50 Data valid for: - Supply air - Blade setting 0 o - Isotherm conditions - Throw without ceiling effect (distance >800 mm. to ceiling) Terminology: - A k = effective free area - V k = effective face velocity - Δp t = total pressure loss - WA = sound power level - l 0,2 = throw to terminal velocity at 0,2 m/s We reserve the right to make changes without prior notice 5

6 Technical data Capacity Air flow rate q v [l/s] and [m /h], total pressure loss Δp t [Pa], throw l 0.2 [m] and sound power level WA [db(a)] can be seen in the diagrams and apply for grilles without an opposed blade damper. Air Jet Dispersal Throw l x [m] at an average speed of 0.2, 0. and 0. m/s, 0 blade setting without ceiling effect (distance from grille to ceiling over 800 mm) can be seen in the diagrams. Correction for dispersal - see table below. Sound power level WA Sound power level WA [db(a)] at 0 blade setting can be seen in the diagrams. The sound power levels apply for grilles without a opposed blade damper. See the table below for correction of sound power level on blade settings [db]. Frequency-related sound power level The sound power level in the frequency band is defined as Wf = WA +K ok. K ok values are given in the table below. Throw and air jet dispersal Throw All given throw data applies for installation more than 800 mm from the ceiling. > 800 For grilles installed less than 00 mm from the ceiling, the air throw is extended by 0% so that: l x result = 1, x l x diagram value < 00 l x l x 1, x Supply air Extract Centre frequency z K 2K K 8K Air jet dispersal Adjustable blade settings for various jet dispersals, correction values can be seen in the table. Opposed blade damper DGS Correction of total pressure loss Δp t [Pa] and sound power level WA [db(a)] using a damper. See table below. x α Damper position Open % Closed 50% Closed Total pressure loss Δp t x 1. x 1. x Sound power level WA X = 5 = α = 5 X = 90 = α = 0 Extract air Total pressure loss Δp t x 0.7 Sound power level WA - 2 We reserve the right to make changes without prior notice

7 Technical data l Δp t [Pa] 0,01 0,02 0,05 0,1 0,2 0, 0, A k [m 2 ] l WA db(a) l l x [m] 0 0,01 0,05 0,1 0,2 0, 0, A k [m 2 ] 1 0 q V [l/s] q V [m /h] Example: size (x): 00 0 mm Free area A k : 0,0 m² Air flow rate q v : 500 m³/h (19 l/s) Result: Sound power level WA : ~ [db(a)] Total presure loss Δp t ~7 [Pa] Throw l 0.2 : ~5, [m] Data valid for: - Supply air - Blade setting 0 o - Isotherm conditions - Throw without ceiling effect (distance >800 mm. to ceiling) For grilles with free area > 0, m 2, we refer to use indabs online calculation tool on We reserve the right to make changes without prior notice 7

Ventilation grille. Dimensions

Ventilation grille. Dimensions Ventilation grille B0 Dimensions B+/A+ B-/A- Description B0 is a rectangular aluminium grille with fixed horizontal bars. B0 is used for both supply and exhaust air, and is supplied as standard with springs

More information

Ceiling diffusers - visible

Ceiling diffusers - visible Ceiling diffusers - visible About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement

More information

Slot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176

Slot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176 B 0 LD- F 9. φ D H H a 8.5 5 5 A E 7 LD- F 8 8.5 9. 5 5 A 7 E LD-/ LD-/ LD- O/ LD- O/ LD- O/ LD- O/.5.5.5.5 LD-/ LD-/ LD-/ LD-/ LD-/ LD-/ 7.5 7.5 07 LD- O/ LD- O/ LD- O/ LD- O/ 5.5 5.5 5.5 5.5 9.5 87.5

More information

Grilles Type AR. AE for return air 1 / 1.3 / B / 1

Grilles Type AR. AE for return air 1 / 1.3 / B / 1 Grilles Type for return air 1 / 1 / B / 1 Contents Description Construction Cover Page 1 Contents 2 Description 2 Construction 2 Materials Standard Sizes Technical Data Technical Data Type Nomenclature

More information

VIREO Ceiling with ALX

VIREO Ceiling with ALX Square ceiling air diffuser with nozzles for supply air, with plenum box QUICK FACTS Flush design Suitable for VAV-applications Fast and easy installation Sealing ring, standard for spigot Energy efficient

More information

NORDgrille Internal grilles

NORDgrille Internal grilles NORDgrille Internal grilles NORDgrille Contents RSP/RSV General grille RPS/RPV General grille RPSL/RPVL Floor grille RSO Transfer air grille RSL Transfer air grille RSM Transfer air grille RSI Exhaust

More information

GTH. Rectangular double deflection grille QUICK FACTS

GTH. Rectangular double deflection grille QUICK FACTS Rectangular double deflection grille QUICK FACTS For supply air Adjustable air deflectors Cleanable Installed using mounting frames FHB / FHA or commissioning box TRG Standard colour White RAL 900 -- alternative

More information

Adjustable swirl diffuser PDZA TECHNICAL DATA

Adjustable swirl diffuser PDZA TECHNICAL DATA Adjustable swirl diffuser PDZA TECHNICAL DATA Adjustable swirl diffuser PDZA Adjustable ceiling swirl diffuser PDZA is intended for commercial and industrial buildings with a large room volume and high

More information

Floormaster DVQA, quarter-cylindrical terminals

Floormaster DVQA, quarter-cylindrical terminals Floormaster DVQA are quarter-cylindrical supply air terminals for positioning on the floor in a corner. The terminals are designed for displacement air handling in accordance with the Floormaster system

More information

BAR GRILLE TYPE: A-600

BAR GRILLE TYPE: A-600 Tel: Sales 0 I Web: www.grada.co.uk TYPE: A00 Installation dimensions AC00 AA00* / AD00 + GR00 0. (+0)(L+0)* / (+0)(L+0) (0)(L0) 0* () (L) ( L) AB00* / AE00 + GR00 (+0)(L+0)* / (+0)(L+0) (0)(L0) 0* ( L)

More information

Nozzle diffuser DYVZ / Supply air unit DYVB TECHNICAL DATA

Nozzle diffuser DYVZ / Supply air unit DYVB TECHNICAL DATA Nozzle diffuser DYVZ / Supply air unit DYVB TECHNICAL DATA Nozzle diffuser DYVZ / Supply air unit DYVB (DYVZ+ATVA) DYVZ DYVB (DYVZ + ATVA) The DYVB is a quiet wall mounted supply air unit that consists

More information

IBISTM. Duct diffuser with discs for supply air

IBISTM. Duct diffuser with discs for supply air TM Duct diffuser with discs for supply air Quick facts 0 flexible distribution pattern High induction capacity Suspended installation Easy installation Modular length: 00 mm Available in alternative colours

More information

IBIS. Duct diffuser with discs for supply air QUICK FACTS

IBIS. Duct diffuser with discs for supply air QUICK FACTS Duct diffuser with discs for supply air QUICK FACTS 0 flexible distribution pattern Suspended installation Easy installation Modular length: 00 mm Standard colour White RAL 900 -- alternative standard

More information

FALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS

FALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS Circular ceiling air diffuser for supply air QUICK FACTS Ceiling air diffuser for supply air in rooms with high ceiling Manual operated change of spread direction as standard Motor operated change of spread

More information

LOOK hidden linear diffusers

LOOK hidden linear diffusers hidden linear diffusers MADEL The hidden linear diffusers are designed to combine the aesthetics with the technical performance. They can be mounted in false ceilings hiding the frame with filler and leaving

More information

DKC. VARIZON Displacement unit with adjustable spread pattern

DKC. VARIZON Displacement unit with adjustable spread pattern VARIZON Displacement unit with adjustable spread pattern Quick facts Adjustable spread pattern and affected area Suitable for all types of room which require large airflows Simple installation Cleanable

More information

Perforated diffuser PAKA, PBKA, PCKA, PDKA, PEKA

Perforated diffuser PAKA, PBKA, PCKA, PDKA, PEKA Perforated diffuser PAKA, PBKA, PCKA, PDKA, PEKA TECHNICAL DATA - 0 page Perforated diffuser PAKA, PBKA, PCKA, PDKA, PEKA Diffusers with perforated panels type PAKA, PBKA, PCKA, PDKA, PEKA can be used

More information

DRI. VARIZON Displacement unit with adjustable spread pattern

DRI. VARIZON Displacement unit with adjustable spread pattern VARIZON Displacement unit with adjustable spread pattern Quick facts Adjustable spread pattern and affected area Suitable for all types of rooms Cleanable Air volume measuring point Very simple to install

More information

Swirl diffusers, Variable swirl diffusers Swirl diffusers

Swirl diffusers, Variable swirl diffusers Swirl diffusers Swirl diffuser OD-7 Fixed blades Different installation possibilities Three possible diffuser shapes St R 90 CD OD-7/R OD-7/K OD-7/RC OD-7/K/PM F 9 x9 φd1 C C F x F C φ D2 φ D 1 9 x 9 Size ФD1 ФD2 ФD F

More information

CEILING SWIRL DIFFUSER MLD

CEILING SWIRL DIFFUSER MLD CEILING SWIRL DIFFUSER MLD Proektasi Makriyianni Ano Ilioupoli P.O.BOX: 6 P.C.: 1 Thessaloniki GREECE Tel.: +0 687 FAX: +0 68047 WEB SITE: www.aerogrammi.gr E-MAIL: info@aerogrammi.gr MLD CEILING ROUND

More information

PERFORMANCE DATA SCD. SCD 12 in. x 12 in. Face Size. SCD 20 in. x 20 in. Face Size. Square Cone Diffuser

PERFORMANCE DATA SCD. SCD 12 in. x 12 in. Face Size. SCD 20 in. x 20 in. Face Size. Square Cone Diffuser 12 in. x 12 in. Face 4 Neck Velocity (fpm) 400 00 00 00 00 900 00 1200 1400 0 Velocity Pressure (in. w.g.)..01.022.031.040.00.02.090.122..013.021.030.041.04.0.04.121.1.21 Flow Rate (cfm) 3 44 2 1 0 4 122

More information

ROL and ROL-S. climecon.fi

ROL and ROL-S. climecon.fi ROL and ROL-S The stylish and silent nozzle duct ROL is designed for rooms requiring large air volumes distributed evenly and without draught. The functional entity is completed by the ROL-S Adjustment

More information

Jet nozzle, type DW-N2 Swivel jet nozzle, type DW-V2 Twist nozzle, type DW-V2-...-DR

Jet nozzle, type DW-N2 Swivel jet nozzle, type DW-V2 Twist nozzle, type DW-V2-...-DR , type DW-N Swivel jet nozzle, type DW-V Twist nozzle, type DW-V-...-DR DS 1 E 0.00/ and twist nozzle Preliminary remarks It is advisable to use nozzles to air-condition large spaces where the supply air

More information

Incorporating V2.2. Product spec >>> > Series CD - Ceiling diffusers

Incorporating V2.2. Product spec >>> > Series CD - Ceiling diffusers Incorporating V2.2 Product spec >>> > Series CD - Ceiling diffusers Diffusers Ceiling (Louvre faced) Recommended for: Ceiling Supply Overview Excellent diffusion characteristics CD4 tile replacers normally

More information

Square swirl diffuser PZK(A,B), PWK(A,B)

Square swirl diffuser PZK(A,B), PWK(A,B) Square swirl diffuser PZK(A,B), PWK(A,B) TECHNICAL DATA - 01 page 4 Square swirl diffuser PZK(A,B), PWK(A,B) PZK(A,B) and PWK(A,B) diffusers assort to swirl devices group. Diffuser s gaps are equipped

More information

Swirl diffusers, Variable swirl diffusers Swirl diffusers

Swirl diffusers, Variable swirl diffusers Swirl diffusers Swirl diffuser O-8 Square or round front plate with radial deflector arrangement Plastic deflectors Possible olume control damper in spigot Foam sealing on the flange St RA 900 C VENTIATING GRIES, VENTIATING

More information

SIRI. Measurement and control damper QUICK FACTS

SIRI. Measurement and control damper QUICK FACTS Measurement and control damper QUICK FACTS Type-approved method of measurement Short installation length Can be cleaned Low flow-generated noise level High measurement accuracy Ductwork leakage class C,

More information

1/S1 VENTILATION GRILLES OAH, OAV, OAB, OAK, OAN, OAS, OAM, OCM, PCR, ORP, PTR, CCH, CCV, NRA, NRB, NRE, NRK. v 3.3 (en)

1/S1 VENTILATION GRILLES OAH, OAV, OAB, OAK, OAN, OAS, OAM, OCM, PCR, ORP, PTR, CCH, CCV, NRA, NRB, NRE, NRK. v 3.3 (en) /S v. (en) OA, OAV, OA, OAK, OAN, OAS, OAM, OCM, PCR, ORP, PTR, CC, CCV, NRA, NR, NRE, NRK TALE OF CONTENTS ALUMINIUM GRILLES Aluminium grilles...9 Special grilles... Fan coil grilles... Steel grilles...

More information

SERIES SS. Air Steel PUBLICATION GRILLES 16 JAN 2015

SERIES SS. Air Steel PUBLICATION GRILLES 16 JAN 2015 PUBLICATION GRILLES 16 JAN 2015 - Wide Selection of Designs and Styles - Flexible Size Range - Natural Stainless Steel Finish Introduction Gilberts Series SS Airsteel. With this new Series Gilberts provide

More information

LOCAL EXTRACTORS. The ideal extractor for industrial environments. Pure advantage

LOCAL EXTRACTORS. The ideal extractor for industrial environments. Pure advantage The ideal extractor for industrial environments. New technology in combination with new materials and a focus on design gives Movex PR many new and important advantages: - Unique ease of maneuverability.

More information

Filter Fan Unit LIGHT

Filter Fan Unit LIGHT Filter Fan Unit LIGHT Type LIGHT EC Technical Concept Technical Concept Filter Fan Unit LIGHT Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air to individual

More information

LDK Slot Diffusers. Description. Throw directions. 2

LDK Slot Diffusers. Description. Throw directions. 2 Slot Diffusers LDK LDK Slot Diffusers Description LDK linear slot diffusers are designed to meet high comfort requirements and modern slot diffuser application standards. LDK slot diffusers, providing

More information

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC Technical Concept Filter Fan Unit LIGHT Type LIGHT AC Type LIGHT EC Filter Fan Unit LIGHT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air

More information

diffusers F24 PERFORMANCE DATA PERFORMANCE DATA ML-37 / ½" SLOT SPACING WIDTH / SUPPLY WITH CONTINUOUS PLENUM Throw correction multiplier for length

diffusers F24 PERFORMANCE DATA PERFORMANCE DATA ML-37 / ½ SLOT SPACING WIDTH / SUPPLY WITH CONTINUOUS PLENUM Throw correction multiplier for length ML-37 / ½" SLOT SPACING WIDTH / SUPPLY WITH CONTINUOUS PLENUM 5-Slot 6-Slot 7-Slot 8-Slot Airflow, cfm/ft. 5 10 16 21 26 31 36 42 47 NC (Noise Criteria) - - 20 27 32 37 40 44 46 Horizontal 1-1-6 3-6-12

More information

Technical Concept. Filter Fan Unit RETURN AIR. Type RA-AC Type RA-EC

Technical Concept. Filter Fan Unit RETURN AIR. Type RA-AC Type RA-EC Technical Concept Filter Fan Unit RETURN AIR Type RA-AC Type RA-EC Filter Fan Unit RETURN AIR Technical Concept Product Description Technical Data M+W Products Filter Fan Units RETURN AIR (FFU-RA) are

More information

Fixed Blade External Louvre

Fixed Blade External Louvre Fixed Blade External Louvre Models FBL and FBL 75 Model FBL Aluminium Construction Bird Wire Guard Standard Two Flange Widths 25mm or 44mm Slim 50mm Section Profile Intake or Exhaust Applications Single

More information

LOCAL EXTRACTORS Pure advantages. The ideal extractor for industrial environments.

LOCAL EXTRACTORS Pure advantages. The ideal extractor for industrial environments. N new materials and a focus on design gives Movex PR many new and important advantages: - Unique ease of maneuverability. H - Hood designed for maximum capture PR's design is based on Movex's basic principles:

More information

S u p p l y a i r h o o d J S I

S u p p l y a i r h o o d J S I Supply air hood JSI PAGE Table of Contents Product description & Product code Functioning principle, Parts Dimensions Positioning, Design Service Exhaust air Pressure loss & sound data Supply air 9 Supply

More information

Catalogue. Swirl 5. Ceiling Swirl Diffuser Fixed Air Pattern.

Catalogue. Swirl 5. Ceiling Swirl Diffuser Fixed Air Pattern. Catalogue Swirl Ceiling Swirl Diffuser Fixed Air Pattern www.air-diffusion.co.uk sales@air-diffusion.co.uk Content Introduction... Technical Description... Performance Data... Quick Selection Data... Selection

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION FORM# 597A-0711 (Replaces 597A- 1004) UNIT FILTER PLENUM CONTROL MOTOR ECONOMIZER FRESH AIR EXHAUST AIR ROOF CURB FLEXIBLE DUCT CON CEN TRIC DIFFUSER BOX INSTALLATION FLUSH MOUNT SYSTEMS Flush

More information

Installation VAV-Compact Retrofit Set

Installation VAV-Compact Retrofit Set VAV-Compact Retrofit Set NMV-D3-RE-SET VAV-Compact Retrofit Set for utilisation of existing VAV devices made by various manufacturers. for various air velocities Suitable for round VAV boxes only. General

More information

Circular and semi-circular displacement outlet Q-Z...

Circular and semi-circular displacement outlet Q-Z... and semi-circular Q-Z... DS 0 E 0.0 and semi-circular Preliminary remarks The circular is installed free standing in the room or - preferably the semicircular model - placed in front of a wall or pillar

More information

Rectangular straight silencer

Rectangular straight silencer silencer DLD Dimensions b a l Description DLD has a conventional design with dimensions that not exceed the corresponding connection dimensions. The silencer can be manufactured in all standard duct sizes.

More information

IRIS Damper Application Guide

IRIS Damper Application Guide IRIS Damper Application Guide IRIS & IRIS-S S INTRODUCTION The IRIS damper is a brilliantly simple solution for fast and exact measurement, balance and control of airflow. It is ideal for supply and exhaust

More information

DCV-SP DCV-SP. DCV-SP Pressure control SPL Version B03 with actuator DA4/8 SMART DAMPERS & MEASURING UNITS. Product description AIN DIN AOUT DCV-SP

DCV-SP DCV-SP. DCV-SP Pressure control SPL Version B03 with actuator DA4/8 SMART DAMPERS & MEASURING UNITS. Product description AIN DIN AOUT DCV-SP DCV-SP Pressure control 24VAC + Communication DIN 24VAC + Communication AIN DCV-SP SMART DAMPERS & MEASURING UNITS Pressure control DCV-SP AOUT RELAY 1(14) Contents Page DCV-SP Introduction... 3 Functional

More information

SLOT DIFFUSERS ALS SERIES SLOT DIFFUSER ALS37. The Airvector exclusive UNIFLEX pattern and volume controller Deflector-damper

SLOT DIFFUSERS ALS SERIES SLOT DIFFUSER ALS37. The Airvector exclusive UNIFLEX pattern and volume controller Deflector-damper SLO DIFFUSERS ALS SERIES SLO DIFFUSER For, and Installation Series ALS Architectural Linear Slot Diffusers are designed for installation in the ceiling, sidewall or sill and are recommended for supplying

More information

7-5/8" 4" wide (cutout) 9-3/4" long. Predictive Placement. SPL How loud will one speaker play, in db, with given amplifier power.

7-5/8 4 wide (cutout) 9-3/4 long. Predictive Placement. SPL How loud will one speaker play, in db, with given amplifier power. 865 In-Ceiling 4-1/4" (depth 9" (flange) BR65 Rough-in Bracket every 8' apart. Keep the speaker 8' grid on ceiling Walls and ceilings. Model 865 is weather-resistant, 104dB each, with 100 watts of amplification.

More information

Emergency stops and Pilot devices

Emergency stops and Pilot devices Emergency stops and Pilot devices IMAGES DESIGNATION ARTICLE NUMBER DESCRIPTION INCA INCA 1 Tina 2TLA030054R0000 Emergency stop button for panel mounting, 22.5 mm holes, Tina adaption unit included for

More information

AV mounting systems Q4-2009

AV mounting systems Q4-2009 AV mounting systems Q4-2009 Table of content 1 Table of content 1 SmartMetals projector mounts 2 Universal tube sets 3 Separate tube sets 4 Mirror kit & anti-theft set 5 Universal projector housings 6

More information

MAC 10. Original & IQ FAMILY OF FAN FILTER UNITS

MAC 10. Original & IQ FAMILY OF FAN FILTER UNITS MAC 10 Original & IQ FAMILY OF FAN FILTER UNITS used in: microelectronics medical device semiconductor disk drive laboratory pharmaceutical markets hospitals clean rooms Table of Contents MAC 10 Original

More information

Laboratory Exhaust Systems

Laboratory Exhaust Systems Laboratory Exhaust Systems Vektor -H Performance High Plume April 07 Laboratory Exhaust Systems Model Vektor -H Table of Contents Vektor-H Specification Chart.... Plume Height Calculation... Quick Select

More information

SINGLE. Technical Data Book. 4Way Cassette S for (Inv, R410A,

SINGLE. Technical Data Book. 4Way Cassette S for (Inv, R410A, SINGLE Technical Data Book 4Way Cassette S for (Inv, R410A, 1 Ver.1.0 Release Single 4Way Cassette S for USA (Inv, R410A, 60Hz, HP) TDB 15.02.05 - Ver.1. 5.0.09 Ver.1..0.0 Ver.1..0. Index 1 Nomenclature

More information

SYSTEM 25 SYSTEM 50 AS SYSTEM 63 SYSTEM 75 SYSTEM 100. Alsident System 50. Antistatic (AS) Product Information

SYSTEM 25 SYSTEM 50 AS SYSTEM 63 SYSTEM 75 SYSTEM 100. Alsident System 50. Antistatic (AS) Product Information Alsident System 50 Antistatic (AS) Product Information . System 50 Antistatic General Information Product Specification Product description System 50 Antistatic Alsident System Airflow between 45-85 m

More information

smartsms-net Networked Smart Sound Masking System Flexibility, simplicity and unrivaled sound masking quality

smartsms-net Networked Smart Sound Masking System Flexibility, simplicity and unrivaled sound masking quality smartsms-net Networked Smart Sound Masking System Flexibility, simplicity and unrivaled sound masking quality The smartsms-net sound masking system allows to implement advanced sound masking systems thanks

More information

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS HV-STYLVENT. Wall or window extract fans. Elegant design harmonising with any environment

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS HV-STYLVENT. Wall or window extract fans. Elegant design harmonising with any environment WALL OR WINDOW EXTRACT FANS Series Complete range of axial flow fans for wall or window mounting applications. All the fans are supplied with tough ABS plastic grilles, shutter and single phase V- 5Hz

More information

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS. Wall or window extract fans HV-STYLVENT. Elegant design harmonising with any environment

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS. Wall or window extract fans HV-STYLVENT. Elegant design harmonising with any environment WALL OR WINDOW EXTRACT FANS HV-STYLVENT Series 688 679 Shutter Reversible Natural ventilation position Complete range of axial flow fans for wall or window mounting applications. All the fans are supplied

More information

SD1 Drywall Installation

SD1 Drywall Installation Specifications: Mounting hardware included Nominal Impedance 8 ohm Impedance (min) 8 ohm Frequency Response (± 3 db) 80 Hz 10 khz Nominal w/o EQ Frequency Response (±10 db) 60 Hz 15 khz Nominal w/o EQ

More information

The VoiceArrest System

The VoiceArrest System The VoiceArrest System Adaptive volume adjustment for optimal efficiency and comfort. The VoiceArrest sound masking system provides advanced sound masking through its networked structure and broad range

More information

TECHNICAL DATA SHEET DS 16S/DS 16SE. FreeSpace. Loudspeakers. Product Overview. Key Features. Product Information. Applications

TECHNICAL DATA SHEET DS 16S/DS 16SE. FreeSpace. Loudspeakers. Product Overview. Key Features. Product Information. Applications Product Overview Bose FreeSpace DS 16S and FreeSpace DS 16SE loudspeakers are high-performance, surfacemount loudspeakers designed for background music and speech reproduction in a wide range of commercial

More information

XENO 8. User & Installation Manual.

XENO 8. User & Installation Manual. XENO 8 User & Installation Manual www.audac.eu 2 Introduction 8 Full range loudspeaker cabinet The XENO series is a loudspeaker range specifically designed for fixed audio installations in modern environments,

More information

Reverse Flow Cabinet. ContraFlo Cabinet. Reverse Flow Cabinet for Raised Floor Data Centers

Reverse Flow Cabinet. ContraFlo Cabinet. Reverse Flow Cabinet for Raised Floor Data Centers Reverse Flow Cabinet ContraFlo Cabinet Reverse Flow Cabinet for Raised Floor Data Centers ContraFlo TM Cabinet Reverse Flow Cabinet The ContraFlo cabinet turns airflow upside down to offer an alternative

More information

Column Series Instruction manual

Column Series Instruction manual Column Series Instruction manual Column Series Instruction manual 3 Column loudspeakers 4 Column cabinet loudspeakers Safety instructions Keep this manual for future reference. Take care of your speaker

More information

NORDdiffuser Diffusers

NORDdiffuser Diffusers NORDdiffuser Diffusers 0 NORDdiffuser Contents DSS Supply air valve DSE Exhaust valve DVP Supply air valve DVS Exhaust valve SFU Supply air valve DKC Ceiling diffuser DKA Ceiling diffuser 0 DSK-P Supply

More information

Reliability and extended operation

Reliability and extended operation CLIMAVENETA TELECOMSOLUTIONS Units for mobile telecounication applications, with free cooling and full DC Inverter technology. 1,5 20. Low operational and maintenance costs Wide range of full inverter

More information

Slim duct (AMTTTFNLDEH ) Indoor units

Slim duct (AMTTTFNLDEH ) Indoor units Slim duct (AMTTTFNLDEH ) Slim duct. Specifications 1) Technical specifications Model AM22FNLDEH AM28FNLDEH AMFNLDEH AM4FNLDEH AMFNLDEH Power Supply Ø, #, V, Hz 1,2,22-24, 1,2,22-24, 1,2,22-24, 1,2,22-24,

More information

Residential air leakage measurement system comparison: Retrotec Blower Door & Minneapolis Blower Door

Residential air leakage measurement system comparison: Retrotec Blower Door & Minneapolis Blower Door Residential air leakage measurement system comparison: Retrotec Blower Door & Minneapolis Blower Door Use this guide to compare features of the two top US manufacturers. Retrotec Model 1000 Blower Door

More information

NORDsilencers Ventilation system silencers

NORDsilencers Ventilation system silencers NORDsilencers Ventilation system silencers NORDsilencers 0 Contents General NRF 0/NRP 0 Silencer NRF 00/NRP 00 Silencer NRFB 0/NRPB 0 Silencer NRFB 00/NRPB 00 Silencer NMF/NMP Silencer NMFE/NMPE Silencer

More information

Control components for VAV terminal units

Control components for VAV terminal units .3 X X testregistrierung Control components for VAV terminal units Type For contaminated extract air or for pressure control Modular control components for VAV terminal units, especially for aggressive

More information

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs

More information

Audio Visual Mounting Solutions

Audio Visual Mounting Solutions ED Audio Visual Mounting Solutions SUPPLYING QUALITY PODUCTS FO OVE 55 YEAS Adjustable Wall Mounts VLM-6600 ED Full Motion TV Wall Mount Screen size 37-90 (94-229cm) Weight capacity 70kg Mounting screw

More information

Catalogue. electric-, cordless- and. pneumatic power tools. Products for sheet metal processing Edition 2008 / 2009

Catalogue. electric-, cordless- and. pneumatic power tools. Products for sheet metal processing Edition 2008 / 2009 Catalogue electric-, cordless- and pneumatic power tools Products for sheet metal processing Edition 2008 / 2009 Machine Tools / Power Tools Laser Technology / Electronics Medical Technology Slitting shears

More information

Frontslide 100/A. Description. Applications. Features of the HAWA-Frontslide 100/A. Patents

Frontslide 100/A. Description. Applications. Features of the HAWA-Frontslide 100/A. Patents Frontslide 100/A Patents Sliding shutters for a functional façade finish. Hardware system for wood, metal or aluminium sliding shutters with a panel weight up to 100 kg (220 lbs.) Guides page 112 Locking

More information

Product Information Fan Powered Terminal Unit For under floor ventilation system Type FAT PI/FAT/M/1

Product Information Fan Powered Terminal Unit For under floor ventilation system Type FAT PI/FAT/M/1 TROX Malaysia Sdn. Bhd. (278360-V) 20, Persiaran Bunga Tanjong 1, Senawang Land Industrial Park, 70400 Seremban, Negeri Sembilan Darul Khusus, Malaysia Telephone : (+6) 06-6788188 Telefax : (+6) 06-6788

More information

CMS 603ICT BM. Optimised for Installation

CMS 603ICT BM. Optimised for Installation Product Information Document Full range ceiling loudspeaker for installation applications 60 Watts continuous, 240 Watts peak power 6" ICT (Inductive Coupling Technology) point source driver for extended

More information

SD1g Glass Applications

SD1g Glass Applications Specifications: Mounting hardware included Nominal Impedance 8 ohm Impedance (min) 8 ohm Frequency Response (± 3 db) 80 Hz 10 khz Nominal w/o EQ Frequency Response (±10 db) 60 Hz 15 khz Nominal w/o EQ

More information

U V-Tu r b o h o o d s

U V-Tu r b o h o o d s U V-Tu r b o h o o d s Product description, Product code Parts Functioning principle Dimensions Exhaust air, pressure loss and sound data Supply air, pressure loss and sound data Distribution of supply

More information

MAC 10 Family of Fan Filter Units.

MAC 10 Family of Fan Filter Units. MAC 10 Family of Fan Filter Units. Used in clean rooms: Microelectronics Nanotechnology Aerospace Medical devices Semiconductor Disk Drive Laboratories Universities Pharmaceutical Hospitals 1 MAC 10 LE-DC

More information

42C/V. Fan Coil Unit Air Flow: 340~2040m 3 /h

42C/V. Fan Coil Unit Air Flow: 340~2040m 3 /h 2/V Fan oil Unit Air Flow: 0~0m 3 /h arrier hina arrier orporation is a subsidiary of the United Technologies orp. (UT), which ranks the 10th in Fortune Top 00 in and has its operations in aerospace and

More information

Hoods, grilles and transitions

Hoods, grilles and transitions Hoods, grilles and s lindab residential ventilation Residential ventilation Circular duct systems Hoods, grilles and s Dampers Silencers Valves and Grilles InCapsa InDomo Access doors Accessories Air handling

More information

GRAFA SYSTEM Design Wilmotte & Industries

GRAFA SYSTEM Design Wilmotte & Industries #CAT family type CRI CCT body color UC-M GR 8 A family type GR = Grafa ystem R = Rectangle (1200x300mm) = quare (600x600mm) CRI CCT body color 8 = 85CRI TYP 30 = 3000K 35 = 3500K A = Clear Anodized 11/16in

More information

Powers TM Controls RL 243 MP Multi-Purpose Relay

Powers TM Controls RL 243 MP Multi-Purpose Relay Powers TM Controls Technical Instructions Document No. 155-042P25 RL 243-6 Description The Powers is a pneumatic auxiliary device designed to provide a variety of pneumatic control functions for the typical

More information

Service poles for industrial applications

Service poles for industrial applications Service poles for industrial applications Ready to go. The ISS basic profile Our industry service poles bundle power, data and compressed air in a compact and robust manner. This means relocations, for

More information

AIR CONDITIONING PRODUCTS COMPANY

AIR CONDITIONING PRODUCTS COMPANY Quality Products for Air Movement Equipment AIR CONDITIONING PRODUCTS COMPANY all Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga le Shutter Drainable Louver Supply Damper Fiberglass

More information

SINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU

SINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU SINGLE Technical Data Book Big Duct for EU (R4A, 0Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU History Version Modification Date Remark Ver 1.0 Release SINGLE Big Duct for EU (R4A, 0Hz, HP)

More information

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions DIFFERENTIAL PRESSURE Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 OPERATIONAL

More information

Cabinet Level Containment. IsoFlo Cabinet. Isolated Airfl ow Cabinet for Raised Floor Data Centers

Cabinet Level Containment. IsoFlo Cabinet. Isolated Airfl ow Cabinet for Raised Floor Data Centers Cabinet Level Containment IsoFlo Cabinet Isolated Airfl ow Cabinet for Raised Floor Data Centers IsoFlo Cabinet Cabinet Level Containment Tate s IsoFlo cabinet completely isolates the IT cooling from the

More information

Krantz. Opticlean Ceiling air outlet for installation in metal ceilings. Air distribution systems

Krantz. Opticlean Ceiling air outlet for installation in metal ceilings. Air distribution systems Krantz Opticlean Ceiling air outlet for installation in metal ceilings Air distribution systems Krantz Opticlean ceiling air outlet Strikingly indiscreet Thanks to its adoption properties, the Opticlean

More information

VRF Technical Data Book

VRF Technical Data Book VRF Technical Data Book Wind-Free 4Way Cassette for North America (R4A, HP) Model : AM***NN4DCH/** History Version Modification Date Remark Ver.1. Released VRF Wind-Free 4Way Cassette for north America

More information

INSTALLATION INSTRUCTIONS ECONOMIZERS WITH EXHAUST. For Use with Bard 3-1/2 through 6 Ton Wall Mount Air Conditioners and Heat Pumps

INSTALLATION INSTRUCTIONS ECONOMIZERS WITH EXHAUST. For Use with Bard 3-1/2 through 6 Ton Wall Mount Air Conditioners and Heat Pumps INSTALLATION INSTRUCTIONS ECONOMIZERS WITH EXHAUST Model EIFM-5C For Use with Bard 3-1/2 through 6 Ton Wall Mount Air Conditioners and Heat Pumps Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since

More information

Global Plasma Solutions. 10 Mall Terrace, Bldg C Savannah, GA (912) ph (877) fax

Global Plasma Solutions. 10 Mall Terrace, Bldg C Savannah, GA (912) ph (877) fax 10 Mall Terrace, Bldg C Savannah, GA 31406 (912) 356-0115 ph (877) 270-5353 fax GPS-RN IOM MANUAL 10 Mall Terrace, Bldg C Savannah, GA 31406 (912) 356-0115 ph (912) 356-0114 fax GPS-RN RTU/AHU INSTALLATION

More information

Sealed Enclosure Cooling Air Conditioners

Sealed Enclosure Cooling Air Conditioners SPECTRACOOL Compact Indoor INDUSTRY STANDARDS UL/cUL Listed; Type 12; File No. SA6453 for N17 UL/cUL Listed; Type 12, 3R, 4, 4X optional; File No. SA6453 and UR/cUR Recognized on select models for N16

More information

FAN FILTER UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

FAN FILTER UNIT KYODO-ALLIED TECHNOLOGY PTE LTD KYODO-ALLIED TECHNOLOGY PTE LTD 8 Pandan Crescent #01-06, Singapore 128464 Tel: (65) 6265 1311 Fax: (65) 6265 8100 Website: www.kyodo.com.sg FEATURES High performance and excellent quality Low energy consumption

More information

Available Beam Angles 8, 15, 30, 45, 40 x 9, 60 x 20 Shielding and Glare Control. EasyGlow TM glare reduction technology

Available Beam Angles 8, 15, 30, 45, 40 x 9, 60 x 20 Shielding and Glare Control. EasyGlow TM glare reduction technology FEATURES The LS9142 is a powerful LED fixture with exceptional light output. Available in a wide variety of optical configurations including narrow spot and bi-symetrical distributions, the LS9142 is a

More information

ZB4BV03 green pilot light head Ø22 with plain lens for BA9s bulb

ZB4BV03 green pilot light head Ø22 with plain lens for BA9s bulb Characteristics green pilot light head Ø22 with plain lens for BA9s bulb Main Range of product Product or component type Product compatibility Device short name Bezel material Mounting diameter Sale per

More information

CI/SfB (35) Xy April Between us, ideas become reality AXIOM C CANOPY. Installation Guide

CI/SfB (35) Xy April Between us, ideas become reality AXIOM C CANOPY. Installation Guide CEILING & WALL SYSTEMS Between us, ideas become reality CI/SfB (35) Xy April 2011 AXIOM C CANOPY Installation Guide 1 PREPARATION SUSPENSION POINTS Suspension points should be determined before installing

More information

Variable Flow Rate Control Unit

Variable Flow Rate Control Unit VAV Produktdata TEKNISK DOKUMENTATION VENTILATION BG BURCHARTH A/S Variable Flow Rate Control Unit Model BVAV-R: VAV unit that has circular section. BVAV-RS: VAV terminal unit. BVAV-Q: VAV unit that has

More information

Instructions for use. MKH 8020 Stereo

Instructions for use. MKH 8020 Stereo Instructions for use MKH 8020 Stereo Contents Important safety information... 2 The MKH 8020... 3 Delivery includes... 4 Putting the microphone into operation... 5 Connecting the microphone... 5 Attaching

More information

Room controller STRA-17

Room controller STRA-17 Room controller STRA-17 Application example Room 2 Room 3 Room 4 SCADA EXOline alt. RS485 Modbus Transformer STRZ-24 (Required component) STRA-17 is a preprogrammed room controller intended to control

More information

VERAK IP. 19 Stand Alone Cabinet with IP65 Rating.

VERAK IP. 19 Stand Alone Cabinet with IP65 Rating. 19 Stand Alone Cabinet with IP65 Rating www.apw.eu.com Overview Material specification Frame: Steel 2.0 mm Panel mounting angles and reducing channels: Steel 2.0 mm Panel mount supports: Steel 1.5 mm Side

More information

MEVDC2 MULTI POINT E X T R A C T

MEVDC2 MULTI POINT E X T R A C T TE CHI C A I FORM AT IO MUTI POIT E X T R A C T A QUIET, EERGY EFFICIET, OW DEPTH CETRA EXTRACT SYSTEM. SAP Q RECOGISED. TE CHI C A I FORM AT IO B E E F I T S MEETS BUIDIG REGUATIOS SAP Appendix Q recognised.

More information